HomeMy WebLinkAboutTHE TABLELANDS BLK 4 LT 10AThe Tablelands Block 4 Lot 10A #051-801-74 Municipality of Anchorage I Page 1 o1 3 Development Services Department Onsite Water and Wastewater Program 4700 Bragaw Street P.O. Box 196650 Anchorage. AK 99519-6650 www.ci.anchorage.ak.us (907) 3437904 j ON-SITE WASTEWATER DISPOSAL SYSTEM AND/OR WELL INSPECTION REPORT Permit Number. SWO50335 PID Number. 051-801.18 S nell Homes Wastewater System: New i 1900 W. Northern Lights, Ste. 200 Anch., AK 99517 ABSORPTION FIELD 344-5678 Foura 4 5' Wide Trench LEGAL DESCRIPTION Sd Rwep Taal Dean ham arpiW Veae. .8 DPD e 31 6b Lat: satee Dsan w PP, tattoo ham a.prw ipr . [xarel a.pn taint Pae. 4 10A The Tablelands 1 Ft. 2 i Ft To. ww: R.pe. wawa Fi.00.a.oar.*N w Vette c a.w Lupin. l 2.3 Ft. 80Ft. Well: AWWUWaterSystem c...a.an. 5 rwro.ar... 1 a.lanC. I Ft. - Cto.rraoal IPnrre, A 9, Ck -Tow D*M: Ca w aw w.a.pwi W"iFe Mwanw. I Ft. I Ft 571 Fe ASTM 3034 PVC Drees Dae Dalee Sewn Wwr Lela. Ft Pisano's Dirtworks 2114-15106 Yea: Nn9 Sw w: Coop Nww Cfaua: TANK CPA, rl Ft SEPARATION DISTANCES Septic i To Septic Absorption Lift Holding umorpowate From Tank Field Station Tank Sewer Line Anchorage Tank 1000 W" >200' >200' N/A WA >25' Steel Two (2) sun.. Wa. >100' >100' WA WA LIFT STATION — NONE ON LOT Lau. >5' >10, WA WA Fauawan >5' >10' WA WA - j e in ti. ti c~Dr None Noted ""°eaLaaa "°'�l`'°°a'a"a.'a"'°w I Ft' BENCH MARK ! Finished Floor. j 100.0 Ft i Engineer's Stamp "Wksya Inspections performed by: T. Kimbrough Dates: 1" 2/14/2006, 49Zh 2 n 2/1512006:._......._ ._.__.........e..e__.......' Department of Health and Human Services approval ;°[ ` -43,11C8- V #w: No Reviewed ��1 and approved by: Date: 0 tt u gf0-9�E* �•' Ixe•. royal ,•a'e�::.�'''' Municipality of Anchorage DEVEOPMENT SERVICES DEPARTMENT 4700 South Bragaw Street Anchorage, AK. 99519-6655 - 343.7904 On -Site Wastewater Disposal System or Well Inspection Report Permit Number. SW050335 92. N to W 1 Page 3 of 3 i PID No. 0511801-18 PROFILE AS -BUILT - Scale: 1-- 10' & ;Cu) O f7 V mc- fn m N =0rn''*1�0 U Nto m�mD� -t61oz6 CD ?grn °y°r' f r-iCD co Z r p o Cn z S 0 m ND D- O —i �oCN Nrn rri :r D —NjrnZ bQ O=1 ZA— o 6) ;00 m o Nzz���D�m zrmozc�'nrz�� m ONO2X�=tmnZmZ A mam ow 0 o CormmQz-oil Zyyoo-fcmi-NiN_WN�Xnm-+ N Z--�(�OMOZC-1� U) 000mom�Q<O- o ;,z oz o o m -9 LIM i z zcom�omlm N 0 0C)r Om m (n -i O 005= O-jEZ D ZzyOO['1*z�< rT' U);u—<zommF)zQ rrl m �o D O o o = �n m ** • "•��♦ +�':;00 �. i • (D p• *�.s�. r + V, •• • : AirAV+ ♦ s ••..: :..• C.7 41V •Rt1e1`�• _ m m r .D r- w O C C7 CC) -P < Cf) O 0CD fel O � oD 0 O N zo 0 o� oN N o r- w O C C7 CC) -P < Cf) O MUNICIPALITY OF ANCHORAGE Development Services Department On -Site Water& Wastewater Program 4700 South Bragaw Street P.O. Box 196650, Anchorage, AK 99519-6650 (907) 343-7904 ON-SITE WASTEWATER DISPOSAL SYSTEM PERMIT Initial Date Issued: Sep 07, 2005 Expiration Date: Sep 07, 2006 Permit Number: SWO50335 Parcel ID: 051-801-18 Legal Description: THE TABLELANDS SUBDIVISION BLOCK 4 LOT 10 Design Engineer: 0014 Anderson Engineering Site Address: 23050 WHISPERING BIRCH DRIVE Owner Name: SPINNEL HOMES, INC. Lot Size: 40000 SO. FT. Owner Address: 1900 W. NORTHERN LIGHTS BLVD #2C Total Bedrooms: 3 Permit Bedrooms: 3 ANCHORAGE. AK 99517 - This permit is for the construction of: ❑✓ Disposal Field ❑✓ Septic Tank ❑ Holding Tank ❑ Privy ❑ Private Well ❑ Water Storage All construction must be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal Code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72 ) and Drinking Water Regulations (18AACBO ). 3. The engineer must notify DSD at least 2 hours prior to each inspection. Provide notification by calling (907) 343-7904 (24 hours). ( Not required for a Water Supply Permit only). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must be either: A. Open and closed on the same day. B. Covered, sealed, and heated to prevent freezing. Received B Issued E Date: i —1—nS Municipality of Anchorage Development Services Department Building Safety Division On -Site Water and Wastewater Program 4700 South Bragaw St. P.O. Box 196650 Anchorage, AK 99519-6650 www.ci.anchorage.ak.us (907) 343-7904 ON-SITE SEWERIWELL PERMIT APPLICATION FOR A SINGLE FAMILY DWELLING Parcel I.D. 0sl - 4>b1 - lis Permit Number SW Property owner(s) Spinell Homes Inc Day phone 344.5678 Mailing address (1)1900 W Northern Lights Blvd Suite 200 Anchorage AK 99517 Mailing address (2).365440 Whispering Birch Drive Zip Code Legal description (Lot, Block & Sub'd.) Lot 10 Block 4. The Tablelands Subdivision,. -- -Legal Legal description (Section, Township & Range) Lot Size 40.000 SF Acres/Sq.Ft. Number of Bedrooms Three (3) THIS APPLICATION IS FOR: Sewer Only ® Well Only ❑ Sewer and Well ❑ Water Storage ❑ Sewer Upgrade ❑ THIS PROPERTY CONTAINS: Hot Tub ❑ Jacuzzi ❑ Swimming Pool ❑ Water Softening Unit ❑ Therapy Pool ❑ certify that the above information is correct. I further certify that this application is being made for a Single Family Dwelling and is in accordance with applicable Municipal Codes. (Signature of property owner or authorized agent) Date of Payment: Receipt Number. dr Receipt Number. (Rev. 12/00) ANDERSON ENGINEERING P.O. BOX 240773 ANCHORAGE, AK 99524 522-7773 677-7766 (FAX August 16, 2005 Municipality of Anchorage Development Services Department On -Site Water and Wastewater Program 4700 South Bragaw Street Anchorage, AK 99519-6650 Subject: Lot 10, Block 4, The Tablelands Subdivision, Addn. No. 1 Septic System Design and Permit Application Impacts to Adjacent Properties Dear Onsite Services Engineer: The owner of Lot 10, Block 4, The Tablelands Subdivision, Addition No. 1 intends to construct a new three-bedroom home on the lot. We are therefore requesting a permit be issued for the construction of a new septic system to serve the new home. The subdivision is currently served by a community water system. No conflicts exist with adjacent septic systems or wells and the proposed septic system on this lot. The attached Site Plan and backup documentation identify the location and configuration of the proposed septic system and alternate site. The current drainage pattern is identified on the Site Plan. The drainage pattern will be maintained after development of this lot is complete. Test holes recently placed on the lot indicated silty gravel with minor amounts of sand in the area of the absorption trench and alternate site. The accepting soils were tested and found to have a percolation rate of 5 minutes per inch. The system is designed with an application rate of .8 GPD/SF which is conservative considering the percolation rate. No groundwater was found in the test holes during placement and none was monitored during the ensuing period. Our design, however, is based on the bottom of the trench at 3' below the surface and includes the placement of a new 1,000 -gallon septic tank along with an 80' long by 5' wide by 2' effective depth absorption trench to collect and treat the sewage generated in the house. The distribution pipe will be 1' below the surface. A minimum of 3' of cover will be placed atop the trench and a minimum of 4' of cover will be placed atop the new septic tank. The ground surface on the lot slopes at varying grades from southeast to northwest as shown on the Site Plan. The absorption trench will be constructed parallel with the Lot 10, Block 4, The Tablelands Subdivision, No. August 16, 2005 Page Two slope of the ground surface as much as possible in conformance with Municipal requirements. The new septic system will be constructed a minimum of 10' from the water service proposed for the lot and on adjacent lots. It will also be constructed a minimum of 100' from any surface water in the area. If the system is constructed in accordance with our design the following statements apply: 1. The system, if constructed as designed, will have no adverse impact on the wells in the area or those to be constructed in the future. 2. The system, if constructed as designed, will have no adverse impact on existing septic systems in the area or those to be constructed in the future. The system, if constructed as designed, will have no adverse impact on reserve space, either surface or subsurface, on any lots located in the area. 4. The system, if constructed as designed, will have no adverse impact on drainage patterns in the area. The current drainage pattern will be maintained. Sincerely, N � Michael E. Anderson, P.E. Attachments •p'41 r� 3r, N O V) 0 M Y � U O /� —JL,: N V / Mtn10 Oti It p h O h C', Q w h J LO Mo Q W W Q w ry N a V) } a n r t� o yJ��B �Ni h t 4.1 C+,z i i •jU� • v: i � �1�d'•• 5 i LOT 10, BLOCK 4, THE TABLELANDS, ADDN. NO. 1 DESIGN FACTORS: Three Bedroom House Perc. Rate: 5 MinAnch Application Rate: .8 GPDISF (AVG. Rate) SYSTEM REQUIREMENTS: 5' Wide Trench System 1,000 Gallon Septic Tank 2' Drainfield Rock 3 Bedrooms X 150 GPD/.8 GPD/SF (Application Rate) = 562.5 SF Absorption Area 562.5 SF/5 LF (Width)' .7(Red. Factor) = 78.75 LF Trench Length THEREFORE: Construct a 80' Long x 5' Wide x 2' Effective Depth Absorption Trench. Flow Line Elevation in Trench to be V Below Original Ground Surface. Total Depth to be 3' Below Existing Ground. Provide 4' Cover Over Septic Tank and 3' Cover Over Absorption Trench. 6" 2'0" Natural Backfill 5' 3' Cover or 2" Insulation and 2' Cover Geotextile Fabric 4" Perforated PVC (Holes Down) Drainfield Rock TYPICAL 5' WIDE TRENCH SE NOTE: SCALE) L-1 Grade Area Over Trench to Drain Away. Minimum 6' Separation From Bedrock Minimum 4' Separation From Groundwater. Minimum 100' Separation From Wells in the Area. Minimum 100' Separation From Surface Water or Streams. MUNICIPALITY OF ANCHORAGE DEVELOPMENT SERVICES DEPARTMENT 4700 SOUTH BRAGAW STREET ANCHORAGE, AK 99519-6650 SOILS LOG - PERCOLATION TEST LEGAL DESCRIPTION. LOT 10, BLOCK 4, TABLELANDS S/D PERFORMED FOR- SPINELL DATE: 6/6/ 005 PROJECT No - M0543 PARCEL IDn• TECHNICIAN: M FI DRIDGE Drrnl I TEST I IOLE # 1 (r�l> F777 OB/OG 2 3 4 i 7 WELL GRADED SANDY - GRAVELS SOME FINES 8 GW -SW 9 SLOPE SITE PLAN THI WAS GROUND WATER ENCOUNTERED? N" 101 IF YES ®WIIAT DEFnit DEIMI OF WATER AFTER MONnORING N— <5% 11 DATE OF MONn ORINO. gni2 S DATE READING GROSS TIME (MINUTES) NET TIME (MINUTES) DEPTH OF WATER (INCHES) NET DROP (INCHES) 6/6/05 TEST HOLE PRESOAKED PRIOR TO TESTING: 1 1435 11.0" CHARGE 2 1505 30 5.0" 6.0" 3 1505 11.0" RECHARGE 4 1535 30 5.0" 6.0" 5 1535 11.0" RECHARGE 6 1605 30 5.0" 6.0" PERCOLATION RATE• 5�O (MIN/INCI I) FERC. HOLE DIA. 6 (INCHES) TEST RUN BETWEEN: L_5 FT. and 5_5 FP, COMMENTS: NO IMPERMEABLE LAYERS ENCOUNTERED. TEST HOLE PRE SOAKED PRIOR TO TEST. TEST PERFORMED BY ANDERSON ENGINEERING. 1, MICHAEL E. ANDERSON CERTIFY THAT THIS WAS PERFORMED IN ACCORDANCE WITI I ALL STATE AND MUNICIPLE GUIDELINES IN EFFECT ON THIS DATE* MUNICIPALITY OF ANCHORAGE DEVELOPMENT SERVICES DEPARTMENT 4700 SOUTH BRAGAW STREET ANCHORAGE, AK 99519-6650 SOILS LOG - PERCOLATION TEST LEGAL DESCRIPTION. LOT 10, BLOCK 4, TABLELANDS S/D PERFORMED FOR- SPINELL DATE: 6/6/2005 PROJECT No - M0543 PARCEL IDn• TECHNICIAN: M FI DRIDGE DI:1'7'1l (fixQ COMMENTS: TEST HOLE #7 2 OB/OG MOIST SILTY SANDS WITH FINES SP -SM WELL GRADED SANDY - GRAVELS SOME FINES GW -SW TH2 O WAS GROUND WATER ENCOUNTERED? Nn IF YES ®WIIAT DFPI1n <5% DEPTH OF WATER AFTER MONITORING: N^ DATE OF MONITORING: !///MOS PERCOLATION RATEL5.0 (MIN/INCII) PERC. HOLE DIA. 6 (INCITES) TEST RUN BETWEEN: 4_5 FT. and 5_5 FI'. NO IMPERMEABLE LAYERS ENCOUNTERED. TEST HOLE PRE SOAKED PRIOR TO TEST. TEST PERFORMED BY ANDERSON ENGINEERING. 1, MICHAEL E. ANDERSON CERTIFY THAT THIS WAS PERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPLE GUIDELINES IN EFFECT ON THIS DATE* READING G OSS TIME MINUTES) NET TIME (MINUTES) Dy ATERF INFT (INCHES) DRDATE NChIES 6/6/05 TEST HOLE PRESOAKED PRIOR TO TESTING: 1 1455 11.01, 1 CHARGE 2 1525 30 4.5" 6.5" 3 1525 11.0" RECHARGE 4 1555 30 5.011 6.0" 5 1555 11.0° RECHARGE 6 1625 30 5.0" 6.011 PERCOLATION RATEL5.0 (MIN/INCII) PERC. HOLE DIA. 6 (INCITES) TEST RUN BETWEEN: 4_5 FT. and 5_5 FI'. NO IMPERMEABLE LAYERS ENCOUNTERED. TEST HOLE PRE SOAKED PRIOR TO TEST. TEST PERFORMED BY ANDERSON ENGINEERING. 1, MICHAEL E. ANDERSON CERTIFY THAT THIS WAS PERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPLE GUIDELINES IN EFFECT ON THIS DATE* MUNICIPALITY OF ANCHORAGE DEVELOPMENT SERVICES DEPARTMENT 4700 SOUTH BRAGAW STREET ANCHORAGE, AK 99519-6650 SOILS LOG - PERCOLATION TEST LEGAL DESCRIPTION. LOT 10, BLOCK 4, TABLELANDS S/D PERFORMED FOR- SPINELL DATE: 8/25/2005 PROJECT No - M0543 PARCEL IDX TECHNICIAN: T I KIMRROtIGH DEPTH (4x0 2 n G 7 n_ 8 w 0 N 9 (ll J 10 I1 ~ w 12 F- 13 COMMENTS: TEST HOLE #73:] OB/OG MOIST SILTY SANDS WITH FINES 99i WAS GROUNDWATER ENCOUNTERED? IF YES® WIIAT DEFnl? DEPTH OF WATER AFTER MONITORING: N. DATE OF MONITORING: swami <5% DATE READING G OSS TIME MINUTES) NET TIME (MINUTES) DEPTH OF INET (IN DROP (INCHES) 8/25/051 TEST HOLE PRESOAKED PRIOR TO TESTING: 1 1220 11.0" CHARGE 2 1235 15 4.25" 6.75" 3 1235 11.0" RECHARGE 4 1250 15 4.25" 6.75" 5 1250 11.0" RECHARGE 6 1305 15 4.375" 1 6.625" PERCOLATION RATE`(MIN/INCII) FERC. HOLE DIA. 6 (INCHES) TEST RUN BETWEEN: 1_5 FT. and 2_5 FT. WAS GROUND WATER ENCOUNTERED? NO IF YES @ WHAT DEPTH? DEPTII OF WATER No IMPERMEABLELAYTER EIRSNENCCOUN E - RD. ST IOLE PRE SOAKED PRIOITORING: DATE OF R To TEST. TEST PERFORMED BY ANDERSON ENGINEERING. 1, MICHAEL E. ANDERSON CERTIFY THAT THIS WAS PERFORMED IN ACCORDANCE WITH ALLSTATE AND MUNICIPLE GUIDELINES IN EFFECT ON THIS DATE* ON-SITE WASTEWATER DISPOSAL SYSTEM CONSTRUCTION AND MATERIAL SPECIFICATIONS SUBJECT: LOT 10, BLOCK 4, TABLELANDS SUBDIVISION, NO. GENERAL: 1. The scope of this project includes the procurement and placement of a new 1,000 -gallon septic tank at the location shown on the Site Plan. Work also includes the construction of a new 80' long X 5' wide X 2' effective depth absorption trench at the location also shown on the Site Plan. The distribution line in the trench will be placed at 1' below the existing ground surface. Total depth of the trench will be 3' below the existing ground surface. A separation distance of 200' from any well and 100' between the septic tank and absorption trench and any surface water must also be maintained. A minimum of 3' of fill is required over the absorption trench and 4' over the septic tank. In lieu of the required fill 2" of insulation and 2' of fill may be placed. 2. Construction shall be in accordance with the approved site plan, design drawings, Municipal Permit with any special provisions or conditions, and all applicable State and Municipal Wastewater Disposal Regulations. 3. The Contractor shall be responsible for obtaining all underground utility locates and for the layout of the septic system and verification of the location of all lot lines. The Contractor must also verify the location of wells in the area and assure that the separation distances are met. 4. Unless specifically agreed otherwise, the contractor shall be responsible for final grading areas subsequently depressed from soil settling. Property owner shall be responsible for revegetation of affected areas unless specifically agreed otherwise. 5. Contractors installing wastewater disposal systems must be certified by the Municipal Department of Health and Human Services for system installations. Owners installing their own systems must receive prior approval from D.H.H.S. before beginning system installation. SEPTIC TANK INSTALLATION A new 1,000 -gallon septic tank must be procured from an approved source and installed at the location shown. 2. A septic tank is to be constructed by a certified septic tank manufacturer. Construction shall include two 4" cleanouts for pumping access. Lot 10, Block 4, Tablelands No.1 August 16, 2005 Page 2 of 3 3. The septic tank shall be sufficiently bedded to prevent settling or shifting of the tank. 4. All standpipes on the septic tank shall extend a minimum of 12 inches above final grade. 5. Tanks installed without 4' of cover shall have a minimum of 2" of direct burial insulation. 6. A foundation cleanout shall be installed one to four feet from the building foundation. Two cleanouts are required between the tank and the drainfield. 7. Final grading over the tank shall be such that a positive slope exists away from the septic tank. DRAINFIELD CONSTRUCTION: 1. The drainfield shall be constructed to the dimensions shown on the design. The bottom of the trench shall be within 2" of level. 2. Distribution piping must be placed level with perforations down atop a level bed of drainfield rock. Rock should then be placed over the pipe to provide a minimum of 2" of cover. 3. A silt barrier or geotextile fabric must be placed between the drainfield rock and the natural soil backfill. 4. Monitor tubes must be 4" in diameter and installed at the locations shown on the design. The portion below ground must be perforated. 5. Contractor shall verify the septic tank and drainfield are a minimum 100' away from any private water wells in the area, 150' from a Class "C" Well or 200' from any community well. 6. Direct bury insulation must be placed over the distribution system if less than 3' of backfill depth is available. Finish grade over the trench must be mounded to prevent settlement or depressions. 7. Grade area surrounding the absorption trench to drain away. 8. A minimum 2' of accepting soil is required below the drainfield rock for a 5' wide trench. Contractor shall verify this condition prior to placement of the rock. All pockets of unacceptable materials must be removed and replaced. Lot 10, Block 4, Tablelands No. 1 August 16, 2005 Page 3 of 3 MATERIAL SPECIFICATIONS: Septic tanks must be constructed by a Municipally approved septic tank manufacturer. 2. The following pipe materials are approved for use in septic system installations in the Municipality of Anchorage: Cast Iron (perforated and solid), ASTM D3034 or P.V.C. (perforated and solid), ASTM F810 or H.D.P.E. (perforated, but not solid) and ASTM D2662 or A.B.S. (perforated and solid). 3. Insulation shall be at least 2" thick extruded direct burial polystyrene (Dow Chemical Co. Styrofoam HI or equal). 4. Septic tank inlets and outlets shall be fitted with watertight couplings (Caulder, Fernco, or equal). 5. A permeable geotextile fabric (Typar, Mirafi or equal) must be installed between the final drain rock layer and the native soil layer. 6. All drain rock shall be .5" to 2.5' in diameter with less than 3% passing the #200 sieve. INSPECTIONS: Municipal Ordinance requires a minimum of two inspections. These inspections must be conducted under the supervision of a professional engineer registered in the State of Alaska. The first inspection must be conducted after the excavation of trenches, beds or pits and before the installation of any gravel. A septic tank may be set in place, but may not be backfilled. The second inspection must be conducted after the placement of the geotextile fabric, gravel, distribution piping, standpipes, cleanouts and insulation. No backfill should be in place at the time of inspection. Contractor shall provide a copy of all field survey layout and construction notes for use in preparing the certified as -built of the completed system. Municipality of Anchorage Development Services Department ae Building Safety Division Onsite Water and Wastewater Program 4700 South Bragaw St. P.O. Box 196650 Anchorage, AK 99519-6650 www.muni.org/onsite (907)343-7904 ON-SITE SEWER/WELL SUBMITTAL COMMENT SHEET To: Anderson Engineering Legal description: The Tablelands. block 4. Lot 10 The attached paperwork has been reviewed and is being returned for the following reasons: ❑ Original signature or stamp missing on ❑ Calculation error in design. ® Additional soils information needed. Need to perc SP -SM soil in TH#2 ❑ Water monitoring results inadequate. ❑ Discrepancy in information submitted. ❑ Topographic information missing or inadequate. _ ❑ Incomplete; missing _ ❑ Incomplete; missing _ ❑ Additional adequacy test information needed. ❑ Water sample unacceptable. _ ❑ Measured/proposed distances/dimensions missing. ❑ Locations of all soils, percolation and water monitoring tests not shown. ❑ Proposed system too deep for soils information submitted. ❑ Well log required. ❑ Omission in narrative. ❑ Insufficient fill over tank or field._ ❑ Other. _ Name of reviewer. Julie Mokela. P.E. Date: 8/23/2005 Please supply the necessary information and re -submit your request. LEAVE THIS FORM ATTACHED TO THE PAPERWORK Municipality of Anchorage Development Services Department Building Safety Division On -She Water and Wastewater Program 4700 Bragaw Street P.O. Box 196650 Anchorage, AK 99519-6650 www.muni.org/onsfte (907) 343-7904 CERTIFICATE OF ON-SITE SYSTEMS APPROVAL FOR A SINGLE FAMILY DWELLING Parcel I.D. 051-901- 714 1. GENERAL INFORMATION COSA # D&[ b3 - Expiration Date: 8fill 4.7 Complete legal description Lot 10A, Block 4, The Tablelands Subdivision Location (site address) 23050 Whispering Birch Drive Chugiak, AK Current Property owner(s) Spinell Homes, Inc. Day phone 344-5678 Mailing address 1900 W. Northern Lights Blvd., Suite 200 Anchorage, AK 99517 Lending agency Day phone II Mailing address Real Estate Agent Day phone Mailing Address Unless otherwise requested, COSA will be held by DSD forpickup. 2. NUMBER OF BEDROOMS: Tree (3) 3. TYPE OF WATER SUPPLY: TYPE OF WASTEWATER DISPOSAL: Individual Well ❑ Individual On-site (] Individual Water Storage ❑ Individual Holding Tank ❑ Community Class Well ❑ Community On-site ❑ Public Water System Public Sewer ❑ The Municipality of Anchorage Development Services Department (DSD) issues Certificates of OnSRe Systems Approval (COSA) based only upon the representations given In paragraph 4 by an independent professional civil engineerucgistemdjr.1he_6tat€9LAlaska,Cedifrcates-ofQtbSite-SySterms APpr9val_prgsequirVdforrJhe_jransfgLgf title (except between spouses) for properties served by a single-family on-site wastewater disposal and/or water supply system. DSD also issues COSAs upon request to homeowners. Certificates of Onsite Systems Approval are valid for 90 days from the date of issue for properties served by a private or Class C well and may be reissued with new water sample results. (Certificates may be reissued for a period of up to one year with valid water samples.) Certificates are valid for one year for properties served by Class A or B wells or a public water system. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. 4. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based on procedures outlined in the Certificate of Onsite Systems Approval Guidelines for this application, shares that the on-sfte water supply and/or wastewater disposal system is (are) safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation. Name of Firm Anderson Engineering Phone 522-7773 Address P.O. Box 240773 Anchorage, AK 99524 Engineers Printed Name Michael E. Anderson, P.E. Date 8/9/2006 5. DSD,SIGNATURE 7 Approved for --3_ bedrooms. Disapproved. Conditional approval for bedrooms, with the following stipulations: Attachments: COSA Checidist X Arsenic Advisory Septic System Advisory Maintenance Agreements Well Flow Advisory Supplemental Engineer's Report Nitrate Advisory Other By. &r Original Certificate Date: 'b I 04 (Rm. I IMS) Municipality of Anchorage Development Services Department Building Safety Division On -Site Water & Wastewater Program 4700 Bragaw Street P.O. Box 196650 Anchorage, AK 995196550 www.muni.ory/onske (907) 3437904 CERTIFICATE OF ON-SITE SYSTEMS APPROVAL CHECKLIST Legai Description: Lot 10, Block 4, The Tabblards Subdivision Parcel ID: 051-01 !18 A. WELL 12ATA Wen type — Date completed — Total depth fL Date of test Static water level Well production IfA, S, or C provide PWSID i/— Sanitary seal (YIN) — Cased to fl FROM WELL LOO WATER SAMPLE RESULTS: Col form colonies/100 mL Nitrate Arsenio _ mgfi B. SEPTICIHOLDINO TANK DATA ll 9— p.m- Wen Log (Y/N) W Ms Property protected (Y/M Casing height (above ground) in. AT INSPECTION mg/L Other Date of sample: _ Collected by: ft. g.P.m. Tank TypeAMatedal SeptlrlSteel Date installed 2H4/2008 ` Tank aim 1,000 gal. Number of Compartments 2 Cleanout, (YIN) Y i Foundation cleanout (YIN) Y Depression over tank (Y/N) N High wader alarm (YIN) !N Data of pumping Now Construction Pumper I C. ABSORPTION FIELD DATA Date installed 2/15/2008 Sail rating (g.p.d.A? or tt=Ibdnn).8 GPD/SF system type 5' Wide Trench Length 80 R Width 5 A. Gravel below pipe 2 R Total depth 67 fL Eftabsorption area 571 fe Monitoring tube V Depression over field N Date of adequacy test New Const. Results (Pass/Fan) For— bedrooms Fluid depth in absorption field before test in. Water added gal. New depth in. Elapsed Time: min. Firm fluid depth in. Any rejuvenation treatment (past 12 mo.) (YIN S type) Absorption rate >= g.p.d. N yes, give date Q LIFT STATION Date installed Size in gallons 'Pump on' level at _ in. 'Pump or level at _ in. E. SEPARATION DISTANCES SEPARATION DISTANCES FROM WELL ON LOT TO: Septic tanUilt station an let Absorption field on krt Public sewer main Sewer /septic service line Manhole/Access (Y/N) High water alarm level at in. Meet slam a circuit ? On adjacent kits On adjacent kits Public sewer manhokr/deanout Holding tank Animal r 1 Inment area Nam Manure/animal excrete storage areas None SEPARATION DISTANCES FROM SEPTICIHOLDING TANK ON LOT TO: Building foundation >S Property One W Absorption field >5 Water main >10' Wefts on adjacent lots >2W Water service One >11Y Surface water >100' SEPARATION DISTANCE FROM ABSORPTION FIELD ON LOT TO: Property One >10' Building foundation >10' Water main >10' Water Service One >1(r Surface water >1W Driveway. parkingNMide steerage >26 Curtain drain Nana Noted Wells on adjacent lots > F. COMMENTS: Lot Is Served by AW WU Water System. G. ENGINEER'S CERTIFICATION e�i I cedtify that I have determined fhrough field Inspections and review of UunA#W records that the above systems are in corAmmance with MOA COSH guidelines m eBed an this date. y Engineer's Printed Name Michael E. Anderson. P.E. Date 9/9/2008 'Vtiap� COSA Fee $ fV".6-0 Waiver Fee $ il 9 Date of Payment to yo Date at Payment Receipt Number o OLM Receipt Number RM. I MM