HomeMy WebLinkAboutKENO HILLS #5 BLK 6 LT 4Keno Hills #5 Block 6 Lot 4 #020-171-32 Municipality of Anchorage Page 1 of 3 Development Services Department On -Site Water and Wastewater Program 4700 South Bragaw Street P.O. Box 196650 Anchorage, AK 995196650 www.d.anchorage.ak.us (907) 945.7904 ON-SITE WASTEWATER DISPOSAL SYSTEM AND/OR WELL INSPECTION REPORT Permit Number. SW040023 PID Number. 020.171.32 Name Jeff Gorton Wastewater System: New Addreea 17815 Ashland Drive Anchors a AK 99516 ABSORPTION FIELD ft� 345-9105 our A 5' Wide Trench LEGAL DESCRIPTION � a TdalDep"r`d"d'° "°"°" 1.2 cpofe 8 FI. 11 d LAX BtLdwe.m Depth to Ddlom adn dpvw pads Cravel depth 1,erYh ppe 6 4 Keno Hills No. 5 3 Ft. 4 FL To.mrep Rana, swan FY added eeore w9" U•de Q> Length 1.3 Ft. 50 Fl. Well: New Gravel v.dN. N m of Irw D. W Eelraen Ynee 5 Fl. 1 - FL CWUGutan 1pnvne,A B. Q. Total Dean cuedto dal aGeaptm res ppe" arw Private 186 FLI 27 FL 500 Fe ASTM 3034 PVC Ordrr Date Droved stat: We. Level inwal.. rw---Ww� Alpine 7121104 21 FL Alaska Pro Truck 71112004 YeW 3 Funp set cee•a Aewe Grd.W >2 TANK cpm Ft. Ft SEPARATION DISTANCES ® Septic ❑ Holding ❑ S.T.E.P. ❑ Other. To Septic Absorption Lift Holing utgripmate From Tank Field Station Tank Sewer Line Anchorage Tank 1,250 well >100' >100' NIA N/A >25'Steel Two (2) Suranw"er >100' >100' NIA NIA LIFT STATION — NONE ON LOT Ld Line >5' >10, NIA NIA cr FouM"m >5' >10, NIA NIA '�'p"' "�° ,Qh'" " in ti k Cute: Dile, None Noted Pump /AeLe Lw"4drullneped.ene pedpmed GF RemaMa BENCH MARK Garage Slab 100.0 FL Engineer's Stamp ���.�waaaaa ?4 i `7 +P'•'' 1� Inspections Inspections performed by: AH Dates: 1" 711104 % 49th '� L : ........; nd 2 711104 r . ............._. ..__.......�.� Department of Health and Human Services approval 0 .A, y N4tut L L. A"DI RSch W Reviewed and approved b QA4 Date: -2 -OS9 -29-0f`'" eb "•• Rt<. tarvpd 14 ............. P� :. s4aa�;5;;��e.• X m o ASHLAND DRIVE a — rr 3 --I c p0 Z� WIJ N 00'04'4514 220.24' CO m OO'pC3 ,* 'g r v 91.24 0 A za w a, o z z 0 N 0 V I O N t \ W O � c N Co T N O lJ O O i � \ 1 l O D oSC) N + z u �z z co ow�� Pi co fig a �^ u o' N� V N a MO vO C14 Q®E N �_ o F--1 h• N _i `° 1O S I m NLn O � N I o u CA 1 V b O U + � WO{yVJ4C uOV'—S m V+bbIG '•���\\\\\,1Sb------------------------------------ ••�• � E 4• 10' UTIL ESML a ..•�h�`••.,�yLN 00'11'1514280.24' o to. FF {# • o :i� "S t E it 1%j .... .•� u u Municipality of Anchorage Page 3 of 3 DEVEOPMENT SERVICES DEPARTMENT 4700 South Bragaw Street Anchorage, AK. 99519-6655 - 343-7904 On -Site Wastewater Disposal System or Well Inspection Report Permit Number. SWO40023 PID No. 020-171-32 PROFILE AS -BUILT - Scale: I"- 11(r ANDERSON ENGINEERING P.O. BOX 240773 ANCHORAGE, AK 99524 522-7773 677-7766 FAX MEMORANDUM DATE: September 28, 2005 TO: Jeff Poet FROM: Mike Anderson, P.E. SUBJECT: Lot 4, Block 6, Keno Hills Subdivision No. 5 Certificate of Health Authority Approval The septic system on the subject lot was constructed by Alaska Pro Truck. They were a certified septic system constructor at the time of the work. Their name has been added to the inspection report. The well log has been modified to reflect the proper legal description. We are unsure as to why the well was placed in the location shown on the as -built. We cannot verify the changed location was coordinated with the City so have paid the $115.00 review fee. Please advise if you have further questions. WAIVER FEE: 1 t5 • Do PAYMENT DATE: 91a s OS PC RECEIPT#: 44OWS 44n MUNICIPALITY OF ANCHORAGE (MINUTES) (INCHES) •OF DEVELOPMENT SERVICES DEPARTMENT 7/1/04 •••�Q� �•'• �� ' 4700 SOUTH BRAGAW STREET ANCHORAGE, AK 99519-6650 • `'• 10:30 9.375" 49th SOILS LOG i..• !!!^��� � 0 2 10:40 ....... _ .._ . _..._.. y 40�.RICINEL E ANIIERSQI j t 2" LEGAL DESCRIPTION: LOT 4, BLOCK 6, KENO HILLS ��s+ No. cE e3e1 rf�: �i •p�L9-or••�.• PERFORMED FOR' JEFF GORTON •�����::::`'••• 10:41 DATE: 7/1/2004 PROJECT No 9.125" PARCEL ID (/• TECHNICIAN: Q. HARALA Pro/essio of Engine" Stamp: DEM 4 TEST HOLE # 4 (fan) 2.125" 7" OB/OG SLOPE SITE PLAN 10:52 9.5" 2 6 11:02 10 3 7" 4 oQs_a:VY; S SEE SITE PLAN .Q ;> 8 o�•'-•• .- •'`a'•�` ° SILTY SAND ,• . ; '� SOME GRAVEL 9 SM •'t` 4 I SEE FUTURE ASSUILT WAS GROUND WATER ENCOUNTERED? No L, •. IF YES ®WHAT DEP'1T i7 4% ^s DEPCH OF WATER AFTER MONITORING: Name a • •' ` o, DATE OF MONITORING: 718N 12 v ,�11 13 e DATE READING GLOSS TIME NET TIME DEPTH 14—o 15—":Q�:o.; 16 4..: BOH 17 18 19 20 PERCOLATION RATE; -1-4 PERC. HOLE DIA 6`•(INCHES) TEST RUN BETWEEN: 4 FT, and 5 FT. NONE COMMENTS: TEST HOLE PRE SOAKED PRIOR TO TEST. SAME MATERIAL AS TEST HOLE 3. TEST PERFORMED BY VETECH ENGINEERING TECHNICAL SERVICE. I, MICHAEL E. ANDERSON CERTIFY THAT THIS WAS PERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPLE GUIDELINES IN EFFECT ON THIS DATE: 4/5/2005 `MINUTES) (MINUTES) (INCHES) NyFE;T DRQQP (INCHES) 7/1/04 TEST HOLE PRESOAKED PRIOR TO TESTING: 1 10:30 9.375" 2 10:40 10 2" 7.375" 3 10:41 9.125" 4 10:51 10 2.125" 7" 5 10:52 9.5" 6 11:02 10 2.5" 7" Y Mayor Municipality of Anchorage Department of Health and Human Services 825 'L' Street P.O. Box 196650 Anchorage, Alaska 99519650 http:/A w.e1.enchonge.aRoe Permit Number: #SW 040023 Date of Issue: 2-18-04 Parcel Identification Number. 020-971-32 Date Started: 7-20-04 Date Completed:? 21-04 Is well located at approved permit location? ® Yes Q No Legal Description: Keno HiNs # 5 Lot 4, Block 6 <r�' 'Property Owner Name & Address: Jeff Gorton PO Box 110384 Anchorage. Alaska 99611 Borehole Data: Depth (it) Method of Drilling ® air rotary Q cable tool Soil Type, Thidmess & Wata Strata From To Casing type: steel Stick up 0 2 Wall Thickness: J_50 inches organks & alit 2 3 Diameter. 6 inches Depth: 2Z feet gravelly sift 3 14 Liner Type: bedrock 14 186 Diameter: inches Depth feet Casing stickup above ground: 2 feet Static water level (from ground level): ,ZLfcct Pumping level: Mfect after 2 how pumping 2 gpm Recovery Rate: I gpm Method of Testing !e r o Well Intake Opening Type: ® Open End ❑ Open Hole ❑ Screened Startfeet Stopped feet ❑ Perforations Start feet Stopped feet Grout Type: bentonite # 8 Volume: L feet Stopped 2 feet If Pump: Intake Depth feet u Pump size _ ho Brand Name Well Disinfected Upon Completion? ® Yes ❑ No Method of Disinfection: chlorine tablets Comments: Well Driller. Alpine Drilling & Enterprlses PO Box 110496 Anchorage Alaska 99511 Attention: The well driller shall provide a well log to the property owner within 30 days of completion and the properly .........A.�..1/./.1//...t.//.....!�..�..///.. .. .L. n... .ftp.. W. � •/...-...I...:......!.4 •. in ./.... .t ......1..l.. MUNICIPALITYOFANCHORAGE Development Services Department On-Site Water & Wastewater Program 4700 South Bragaw Street P.O. Box 196650, Anchorage, AK 99519-6650 (907) 343-7904 ONSITE WASTEWATER DISPOSAL SYSTEM I WATER SUPPLY PERMIT Initial Permit Number: SW040023 Date Issued: Feb 18, 2004 Expiration Date: Feb 17, 2005 Parcel ID: 020-171-32 Legal Description: KENO HILLS #5 SUBDIVISION BLOCK 6 LOT 4 " Design Engineer: 0014 Anderson Engineering Site Address: 17815 ASHLAND DRIVE Owner Name: JEFF GORTON Lot Size: 104544 SO. FT. Owner Address: 17815 ASHLAND DRIVE Total Bedrooms: 4 Permit Bedrooms: 4 ANCHORAGE. AK 99516 - This permit is for the construction of: ❑✓ Disposal Field 0 Septic Tank ❑ Holding Tank ❑ Privy Private Well ❑ Water Storage All construction must be in accordance with: 1. The attached approved design. 2. All requirements specified In Anchorage Municipal Code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations ( 18AAC72 ) and Drinking Water Regulations (18AAC80 ). 3, The engineer must notify DSD at least 2 hours prior to each Inspection. Provide notification by calling (907) 343-7904 ( 24 hours ). ( Not required for a Water Supply Permit only). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must be either: A. Open and closed on the same day. B. Covered, sealed, and heated to prevent freezing. Received By: Issued By. Date: 9 Date: 2 Ile 0 ¢ Municipality of Anchorage • Development Services Department Building Safety Division On -Site i Water and Wastewater Program 4700 South Bragaw St. P.O. Box 196650 Anchorage, AK 99519-6650 www.ci.enchorage.ak.us (907) 343-7904 ON-SITE SEWER/WELL PERMIT APPLICATION FOR A SINGLE FAMILY DWELLING ZD Parcel I.D. 020.17132 Permit Number SW 0 400 2 3 Property owner(s) Jeff Gorton Day phone 229.2220 Mailing address (1) P.O. Box 110384 Anchorage, AK 99511 Slrf -Mnitiag address (2)179/S pSHLgivD DR. r AV[N. 7Zip Code Legal description (Lot, Block & Sub'd.) Legal description (Section, Township & Range) 104 F44 Lot Size 2.4 kres Acre q.Ft THIS APPLICATION IS FOR: Number of Bedrooms Four (4) Sewer Only ❑ Well Only ❑ Sewer and Well ® Water Storage ❑ Sewer Upgrade ❑ THIS PROPERTY CONTAINS: Hot Tub ❑ Jacuzzi ❑ Swimming Pool ❑ Water Softening Unit ❑ Therapy Pool ❑ certify that the above information is correct. I further certify that this application is being made for a Single Family Dwelling and is in accordance with applicable Municipal Codes. (Signature of property owner or authorized agent) Permit Fees: Date of Paymi Receipt Numb (Rev. 12100) Waiver Fees: Date of Payment: Receipt Number: ANDERSON ENGINEERING P.O. BOX 240773 ANCHORAGE, AK 99524 522-7773 522-6779 FAX February 13, 2004 Municipality of Anchorage Development Services Department On -Site Water and Wastewater Program 4700 South Bragaw Street Anchorage, AK 99519-6650 Subject: Lot 4, Block 6, Keno Hills Subdivision No. 5 Septic System Design and Permit Application Impacts to Adjacent Properties Dear Onsite Services Engineer: The owner of Lot 4, Block 6, Keno Hills Subdivision No. 5 intends to construct a four- bedroom home on the lot. We are therefore requesting a permit be issued for the construction of a new well and septic system to serve the new home. The attached Site Plan and backup documentation identify the location and configuration of the proposed well, septic system and alternate site. The lot is nearly 2.4 acres in surface area and no conflicts exist between the well and septic system on this lot and those on adjacent properties. Drainage arrows with representative surface slopes are shown on the Site Plan. The drainage pattern will be maintained after development of this lot is complete. Test holes placed on the lot in the area of the new absorption trench indicated sand with silt and minor amounts of gravel with percolation rates ranging from 2 to 5 minutes per inch. No groundwater was found during excavation and none was noted during the monitoring period. We are therefore proposing to place a new 1,250 -gallon septic tank along with a 50' long by 3' wide by 4' effective depth absorption trench to collect and treat the sewage generated in the house. The bottom of the trench will be 8' below the surface. A minimum of 3' of cover will be placed atop the trench and 4' atop the new septic tank. The ground surface on the lot slopes at shallow grades from east to west as shown on the Site Plan. The absorption trench will be constructed parallel with the slope of the ground surface as much as possible in conformance with Municipal requirements. The new septic system will be constructed a minimum of 100' from the well proposed for the lot and on adjacent lots. It will also be constructed a minimum of 100' from any surface water in the area. Lot 4, Block 6, Keno Hills Subdivision No. 5 February 13, 2004 Page Two If the system is constructed in accordance with our design the following statements apply: The system, if constructed as designed, will have no adverse impact on the wells in the area or those to be constructed in the future. 2. The system, if constructed as designed, will have no adverse impact on existing septic systems in the area or those to be constructed in the future. 3. The system, if constructed as designed, will have no adverse impact on reserve space, either surface or subsurface, on any lots located in the area. 4. The system, if constructed as designed, will have no adverse impact on drainage patterns in the area. The current drainage pattern will be maintained. Sincerely, IACX� E-a� Michael E. Anderson, P.E. Attachments *" L *V' lr MIDNAEL E. MDERSON 4 No. cE-4381 � N89 5vi" 373 07 8 g � O 6 �,/ 6 o �8 3 s 1189 5515E MOO 0 co s 1Li7Ile 30, • nr N 1 325.7E N895S1 3S+ 6 O ♦�*$V*uu%%tA 5 �O E............ 49 � �i MCM/iEl E.uoEnwN � '^ �v�J, L, No. ce.aet� .I,,w JAI 8 toM+E�n AREA MAP SCALE V • 100' I .�� '..,,...., I r. ,4Z'08Z M.913 3.00 N ♦♦hrr ••��� •� ---------------1WS3 -iiin ,OL— S o � n z x � m W N a`d Q LL,v LO c°fp 00 ,^ •z H•Z N Off- N all + 0 h Q� "J rg� 32.1 S 450.00 tZ'OZZ M.94,40.00 N LS32 00 R.Sp. O "� 3AIaG dNVIHSV LOT 4, BLOCK 6, KENO HILLS, ADDN. NO.5 DESIGN FACTORS: SYSTEM REQUIREMENTS: Four Bedroom House 5' Wide Trench System Perc. Rate: <5 Min./Inch 1,250 Gallon Septic Tank Application Rate: 1.2 GPD/SF 4' Drainfield Rock 4 Bedrooms X 150 GPD/1.2 GPD/SF (Application Rate) = 500 SF Absorption Area 500 SF/5 LF (Width)' .5(Red. Factor) = 50 LF Trench Length THEREFORE: Construct a 50' Long x 5' Wide x 4' Effective Depth Absorption Trench. Flow Line Elevation in Trench to be 4' Below Original Ground Surface. Total Depth to be 8' Below Existing Ground. Provide 4' Cover Over Septic Tank and 3' Cover Over Absorption Trench. TV 6" 4'0" Natural Backfill 5' FI Geotextile Fabric 4' Perforated PVC (Holes Down) Drainfield Rock TYPICAL 5' WIDE TRENCH SECTION P* E OF 4 (NO SCALE) �� p(.. ».._•' NOTE: Grade Area Over Trench to Drain Away. : a/ Minimum 6' Separation From Bedrock. .'.... 49 Minimum 4' Separation From Groundwater. i. Minimum 100' Separation From Well. 0 MC UEL E.ANOE0.50H Minimum 100' Separation From Surface Water or Streams. 10, sA No. u4mi MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH & HUMAN SERVICES 825 L STREET, ANCHORAGE, AK 99502-0605 SOILS LOG - PERCOLATION TEST PROJECT #: PERFORMED FOR: - Jeff Gorton DATE PERFORMED: 7/9/03 LEGAL DESCRIPTION: Lot 4. Block 6. Keno Hills Subdivision TEST HOLE # 1 SLOPE SITE PLAN Organic Layer - OL 2 S NET TIME L IF YES, WHAT DEPTH? 0 3 :.: AFTER MONITORING: 4 1 Silty Sand 30 Dry SM 5 5:46 6 Some Gravel 7 30 Dry 12" Recharge 6:17 8 12.0" 3 6:47 30 9 10—. I I Silty Sand Tighter with Depth 12 v :..'.::; SM 13 .•'LE0 49th 15 OA 1.... � 17-� I BOH - s :j WAS GROUNDWATER ENCOUNTERED? NO S NET TIME L IF YES, WHAT DEPTH? 0 DEPTH OF WATER None P AFTER MONITORING: E MIn41LLL/JD[HSOH u4ml Vi DATE: 7/15/2003 �I o TH20 ,� TH30 a I TH10 4% i READING DATE GROSS TIME NET TIME DEPTH OF WATER NET DROP Start 7/9/03 5:15 12.0" 1 5:45 30 Dry 12" Recharge 5:46 12.0" 2 6:16 30 Dry 12" Recharge 6:17 12.0" 3 6:47 30 Dr PERC RATE: 2.5 MIN./INCH PERC. HOLE DIAMETER: 6" TEST RUN BETWEEN 3.0 FT. AND 4.0 T. COMMENTS: Test Hole Pre Soaked Prior to Percolation Test. TEST PERFORMED BY: MEA I, MICHAEL E. ANDERSON, CERTIFY THAT THIS TEST WAS PERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES ON THIS DATE: 2/12/2004 MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH 8 HUMAN SERVICES 825 L STREET, ANCHORAGE, AK 99502-0605 SOILS LOG - PERCOLATION TEST PROJECT #: PERFORMED FOR: Jeff Gorton DATE PERFORMED: 7/9/03 LEGAL DESCRIPTION: Lot 4. Block 6. Keno Hills Subdivision TEST HOLE # 2 SLOPE SITE PLAN z GROSS TIME Organic Layer- OL DEPTH OF WATER NET DROP Start 7/9/03 4:30 3 8.5" 4 5:00 Silty Sand Dry 8.5" SM 5 8.5" 6 2 5:31 30 Dry Some Gravel 7 5:32 8 3 6:02 30 Dry BY ,•,. WAS GROUNDWATER 9— ENCOUNTERED? Silty Sand 10 Tighter with Depth IF YES, WHAT DEPTH? �. $M DEPTH OF WATER I I AFTER MONITORING: DATE: 12 - OF �...i%.� 49th....... .....0 E AMERSOR j W W� .�.. •' •� J`::, No. Cavi i ire 17--1 I BOH - 16' NO None 7/1S/2003 S L 0 P E �I o` TH2O TH30 a I THP 4% READING DATE GROSS TIME NET TIME DEPTH OF WATER NET DROP Start 7/9/03 4:30 8.5" 1 5:00 30 Dry 8.5" Recharge 5:01 8.5" 2 5:31 30 Dry 8.5" Recharge 5:32 8.5" 3 6:02 30 Dry BY FERC RATE: 3.5 MIN./INCH FERC. HOLE DIAMETER: TEST RUN BETWEEN 4.0 FT. AND S.0 T. COMMENTS: Test Hole Pre Soaked Prior to Percolation Test. TEST PERFORMED BY: MEA I, MICHAEL E. ANDERSON, CERTIFY THAT THIS TEST WAS PERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES ON THIS DATE: 2/12/2004 MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH & HUMAN SERVICES 825 L STREET, ANCHORAGE, AK 99502-0605 SOILS LOG - PERCOLATION TEST PROJECT #: PERFORMED FOR: Jeff Gorton DATE PERFORMED: 7/9/03 LEGAL DESCRIPTION: Lot 4. Block 6. Keno Hills Subdivision • 49th='••':�}I�r ;h. DOURLAWERUONL o. a4341 W 4. 17 -JI BOH - 16'r••�"�" SLOPE NO None 7/15/2003 S L 0 P E SITE PLAN �I o` TH2O TH30 a I TH10 4% READING DATE GROSS TIME TEST HOLE # 3 Organic DEPTH OFEDROP WATERStart 7/9 Layer- OL 2 5:10 30 Dr 3 :. 5:11 8.5"2 Silty Sand 5:41 SM 5 � , Recharge 6 1 Some Gravel 7 3 6:12 8 Dr ~ WAS GROUNDWATER 9 ENCOUNTERED? Silty Sand 10 :..' : Tighter with Depth IF YES, WHAT DEPTH? �. SM DEPTH OF WATER 11 AFTER MONITORING: . ' DATE: 12 Y .. .. • 49th='••':�}I�r ;h. DOURLAWERUONL o. a4341 W 4. 17 -JI BOH - 16'r••�"�" SLOPE NO None 7/15/2003 S L 0 P E SITE PLAN �I o` TH2O TH30 a I TH10 4% READING DATE GROSS TIME NET TIME DEPTH OFEDROP WATERStart 7/9 4:40 8.5"1 5:10 30 Dr Recharge 5:11 8.5"2 5:41 30 Dr Recharge 1 5:42 1 8.5" 3 6:12 30 Dr PERC RATE: 3.5 MIN./INCH PERC. HOLE DIAMETER: TEST RUN BETWEEN 5.0 FT. AND 6.0 T. COMMENTS: Test Hole Pre Soaked Prior to Percolation Test. TEST PERFORMED BY: MEA I, MICHAEL E. ANDERSON, CERTIFY THAT THIS TEST WAS PERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES ON THIS DATE: 2/12/2004 ON-SITE WASTEWATER DISPOSAL SYSTEM CONSTRUCTION AND MATERIAL SPECIFICATIONS SUBJECT: LOT 4, BLOCK 6, KENO HILLS, ADDITION NO.5 GENERAL: 1. The scope of this project includes the procurement and placement of a new 1,250 -gallon septic tank at the location shown on the Site Plan. Work also includes the construction of a new 50' long X 5' wide X 4' effective depth absorption trench at the location also shown on the Site Plan. The distribution line in the trench will be placed at 4' below the existing ground surface. Total depth of the trench will be 8' below the existing ground surface. The new septic tank and absorption trench must be placed a minimum of 100' from the well on this and adjacent lots. 2. Construction shall be in accordance with the approved site plan, design drawings, Municipal Permit with any special provisions or conditions, and all applicable State and Municipal Wastewater Disposal Regulations. 3. The Contractor shall be responsible for obtaining all underground utility locates and for the layout of the septic system and verification of the location of all lot lines. The Contractor must also verify the location of wells in the area and assure that the separation distances are met. 4. Unless specifically agreed otherwise, the contractor shall be responsible for final grading areas subsequently depressed from soil settling. Property owner shall be responsible for revegetation of affected areas unless specifically agreed otherwise. 5. Contractors installing wastewater disposal systems must be certified by the Municipal Department of Health and Human Services for system installations. Owners installing their own systems must receive prior approval from D.H.H.S. before beginning system installation. SEPTIC TANK INSTALLATION A new 1,250 -gallon septic tank must be procured from an approved source and installed at the location shown. 2. A septic tank is to be constructed by a certified septic tank manufacturer. Construction shall include two 4" cleanouts for pumping access. 3. The septic tank shall be sufficiently bedded to prevent settling or shifting of the tank. Lot 4, Block 6, Keno Hills No. 5 February 13, 2004 Page 2 of 3 4. All standpipes on the septic tank shall extend a minimum of 12 inches above final grade. 5. Tanks installed without 4' of cover shall have a minimum of 2" of direct burial insulation. 6. A foundation cleanout shall be installed one to four feet from the building foundation. Two cleanouts are required between the tank and the drainfield. 7. Final grading over the tank shall be such that a positive slope exists away from the septic tank. DRAINFIELD CONSTRUCTION: 1. The drainfield shall be constructed to the dimensions shown on the design. The bottom of the trench shall be within 2" of level. 2. Distribution piping must be placed level with perforations down atop a level bed of drainfield rock. Rock should then be placed over the pipe to provide a minimum of 2" of cover. 3. A silt barrier or geotextile fabric must be placed between the drainfield rock and the natural soil backfill. 4. Monitor tubes must be 4" in diameter and installed at the locations shown on the design. The portion below ground must be perforated. 5. Contractor shall verify the septic tank and drainfield are a minimum 100' away from any private water wells in the area, 150' from a Class "C" Well or 200' from any community well. 6. Direct bury insulation must be placed over the distribution system if less than 3' of backfill depth is available. Finish grade over the trench must be mounded to prevent settlement or depressions. 7. Grade area surrounding the absorption trench to drain away. 8. A minimum 2' of accepting soil is required below the drainfield rock for a 5' wide trench. Contractor shall verify this condition prior to placement of the rock. All pockets of unacceptable materials must be removed and replaced. MATERIAL SPECIFICATIONS: 1. Septic tanks must be constructed by a Municipally approved septic tank manufacturer. Lot 4, Block 6, Keno Hills No. 5 February 13, 2004 Page 3 of 3 2. The following pipe materials are approved for use in septic system installations in the Municipality of Anchorage: Cast Iron (perforated and solid), ASTM D3034 or P.V.C. (perforated and solid), ASTM F810 or H.D.P.E. (perforated, but not solid) and ASTM D2662 or A.B.S. (perforated and solid). 3. Insulation shall be at least 2" thick extruded direct burial polystyrene (Dow Chemical Co. Styrofoam HI or equal). 4. Septic tank inlets and outlets shall be fitted with watertight couplings (Caulder, Femco, or equal). 5. A permeable geotextile fabric (Typar, Mirafi or equal) must be installed between the final drain rock layer and the native soil layer. 6. All drain rock shall be .5" to 2.5" in diameter with less than 3% passing the #200 sieve. INSPECTIONS: Municipal Ordinance requires a minimum of two inspections. These inspections must be conducted under the supervision of a professional engineer registered in the State of Alaska. The first inspection must be conducted after the excavation of trenches, beds or pits and before the installation of any gravel. A septic tank may be set in place, but may not be backfilled. The second inspection must be conducted after the placement of the geotextile fabric, gravel, distribution piping, standpipes, cleanouts and insulation. No backfill should be in place at the time of inspection. Contractor shall provide a copy of all field survey layout and construction notes for use in preparing the certified as -built of the completed system. Municipality of Anchorage • -� Development Services Department Building Safety Division On -Site Water 8 Wastewater Program 4700 Bragaw Street P.O. Box 196650 Anchorage, AK 99519-6650 www.muni.org/onsite (907)343-7904 CERTIFICATE OF ON-SITE SYSTEMS APPROVAL V2 �11 FOR A SINGLE FAMILY DWELLING??,, Parcel I.D. —'7I -�V 2_ COSA# q 0307 1. GENERAL INFORMATION Expiration Date: Complete legal description Location (site address) Current Property owner(s) Mailing address Lending agency Mailing address Real Estate Agent Mailing address KENO HILLS #50 BLOCK 6 LOT 4 17815 ASHLAND DRIVE • ANCHORAGE. AK * 99516 KYLE AND SALLY RANDICH Day phone 345-4134 17815 ASHLAND DRIVE " ANCHORAGE, AK . 99516 Day phone JERI JEFFREY W/ PRUDENTIAL JACK WHITE Day phone 762-3108 3801 CENTERPOINT DRIVE #200 * ANCHORAGE. AK " 99503 Unless otherwise requested, COSA will be held by DSD for pickup. 2. NUMBER OF BEDROOMS: 1 4 3. TYPE OF WATER SUPPLY: Individual Well 0 Individual Water Storage ❑ Community Class Well ❑ Public Water System ❑ TYPE OF WASTEWATER DISPOSAL: Individual On-site N Individual Holding tank ❑ Community On-site ❑ Public Sewer ❑ The Municipality of Anchorage Development Services Department (DSD) Issues Certificates of On -Site Systems Approval (COSA) based only upon the representations given in paragraph 4 by an independent professional civil engineer registered in the State of Alaska. Certificates of On -Site Systems Approval are required for the transfer of title (except between spouses) for properties served by a single-family on-site wastewater disposal and/or water supply system. DSD also issues COSAs upon request to homeowners. Certificates of On -Site Systems ' Approval are valid for 90 days from the date of Issue for properties served by a private or Class C well and may be reissued with new water samples. (Certificates may be reissued for a period of up to one year with valid water samples.) Certificates are valid for one year for properties served by Class A or B wells or a public water system. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. 4. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based on procedures outlined in the Certificate of On -Site Systems Approval Guidelines for this application, shows that the on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage (les and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation. Name of Firm GARNESS ENGINEERING GROUP, Ltd. Phone 337-6179 Address 3701 E. TUDOR ROAD. SUITE 101 • ANCHORAGE. AK 99507 Engineer's Printed Name JEFFREY A. GARNESS. P.E. Date f I c 1 Engineer's Comments: In conducting this evaluation, GEG, UD. attempted to provide a thorough, conscientious engineering analysis of the system in accordance with ADEC and MOA DSD Guidelines d Regulations. The reported results described the performance of the system under the conditions encountered at the time of the test, and separation distances measured to readily identifiable features. The operational life of all wells and septic systems depend on the local soils condition, groundwater levels that may fluctuate during the year, and the water usage of the family being served by the system. These conditions are outside the control of the evaluator of the system. Satisfactory test results do not guarantee future performance of the system, nor do they guarantee that there are no hidden defects or encroachments. GEG, LTD. can therefore not provido any warranty or future estimate of how long the system will continue to meet the operational requirements of the ADEC or MOA DSD. The content of this report is for the sole benefit of the owner listed above. Any reliance upon or use of this report by any other person or party is not authorized, nor will It confer any legal right whatsoever. 5. DSD SIGNATURE Approved for bedrooms. Disapproved. 13.1 •"I� f A. Go ness. 0 a CE -a` ' • qrl o� • VC Conditional approval for bedrooms, with the flowing stipulations: Attachments: COSA Checklist Septic System Advisory Well Flow Advisory Arsenic Advisory Maintenance Agreements Supplemental Engineer's Report Nitrate Advisory Other (Rw JIM) 'R�4�vY OF',., c�Q.•' do ONSITE WATER AND WASTEWATER PROGRAM ' Original Certificate Date: - I - q - 0 Municipality of Anchorage .0 , �• -�� Development Services Department Building Safety Division On -Site Water 8 Wastewater Program 4700 Bragaw Street P.O. Box 196650 Anchorage, AK 99519650 www.muni.org/onsite (907) 343-7904 CERTIFICATE OF ON-SITE SYSTEMS APPROVAL CHECKLIST Legal Description: KENO HILLS #5; BLOCK 6, LOT 4 Parcel ID: 0 V, o- /'7 1- 3.9, A. WELL DATA *INTO BEDROCK Well type MOTE If A, B, or C provide PWSID# N/A Date completed 7/21/2004 Sanitary seal (Y/N) YES Total depth 186 ft. Cased to '27 ft. FROM WELL LOG Date of test 7/21/2004 Static water level 21 ft. Well production 3 g.p.m. WATER SAMPLE RESULTS: Coliform n colonies/100 ml. Arsenic: fJ0ug./L. B. SEPTIC/HOLDING TANK DATA Well Log (Y/N) YES Wires properly protected (Y/N) YES Casing height (above ground) 2 in. AT INSPECTION 8/19/2009 31 ft. 2.26 g.p.m. Nitrate mg./L. Date of sample: 8 19/2 009 Tank Type/Material SEPTIC/STEEL , Tank size' 1250 gal. Number of Compartments 2 Other bacteria b colonies/100 ml. Collected by: GEG Ltd. Date installed 7/1/2004 Cleanouts (YIN) YES Foundation cleanout (Y/N) YES Depression over tank (Y/N) NO High water alarm (Y/N) N/A Date of pumping 8/20/2009 Pumper _ MCDONALDS PUMPING C. ABSORPTION FIELD DATA E ow EXISTING GRAD Date installed 7/11/2004 Soil rating (2Yor ft'/bdrm) 1_2 System type SHALLOW TRENCH Length 50 ft, Width 5 ft. Gravel below pipe 4 ft. Total depth •9.6 ft. Eff. absorption area 500 ft' Monitoring tube YES Depression over field NO Date of adequacy test 8/19/2009 Results (Pass/Fail) PASS 1 For 4 bedrooms Fluid depth in absorption field before test 20 in:. Water added 600 gal. New depth 26.5in. Elapsed Time: 140• min. Final fluid depth 25 in. Absorption rate >= 600+ g.p.d. Any rejuvenation treatment (past 12 mo.) (YIN 8 type) NONE KNOWN If yes, give date D. LIFT STATION Date installed Size In gallons Manhole/Access (Y/N "Pump on" level at in. "Pump off' level i . High water alarm level at Cycles tested Meets alarm & circuit requirements? E. SEPARATION DISTANCES SEPARATION DISTANCES FROM WELL ON LOT TO: Septic tankfift station on lot 100'+ On adjacent lots 100'+ Absorption field on lot 100'+ On adjacent lots 100'+ Public sewer main N/A Sewer /septic service line 25'+ Public sewer manhole/cleanout Holding tank N/A Animal containment areas 50'+ Manure/animal excrete storage areas 100'+ SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK ON LOT TO: Building foundation 5'+ Property line 5'+ Absorption field 5'+ Water main N/A Water service line 10'+ Surface water 100'+ Wells on adjacent lots 100'+ SEPARATION DISTANCE FROM ABSORPTION FIELD ON LOT TO: Property line 10'+ Building foundation 10'+ Water main N/A Water service line 10'+ Surface water 100'+ Driveway, parking/vehicle storage 10'+ Curtain drain NONE KNOWN Wells on adjacent lots 100'+ F. COMMENTS G. ENGINEER'S CERTIFICATION I certify that I have determined through field inspections and review of Municipal records that the above systems are in conformance with MOA COSA guidelines in effect on this date. Engineer's Printed Name JEFFREY A. GARNESS Date q/I Joe, ��i�i1.r' "i'"i►y�� A. Lorne s, O� C 953 ,•';`FOS q vA*'00resStu / COSA Fee S �1 / 0 " Waiver Fee $ Date of Payment 131/1 0 9 Date of Payment Receipt Number_ O Co 03 7 3 Receipt Number (Rev. 11/05) SCS Retia 1094304001 Client Name Garness Engineering Group, Ltd Project Name/9 Keno Hills #5 B6,LA Client Sample 11) Keno Hills #5 B6,1A Matrix Drinking Water Printed Dau/rime 08312009 15:12 Collected Daterrime 08.'192009 18:00 Received Date/rime 08202009 8:10 Technical Director Stephen C. Ede Sample Remarks: Alloxable Prep Analysis Parameter Results PQL Units Method Container lD Limits Date Date hot Metals by ICP/MS Arsenic ND 5.00 ug/L EP200.8 C (<10) 0826/09 0888/09 NRB Waters Department Total Nitrate .Nitrite -N ND 0.100 mg(L SM20 4500NO3-F D (<10) 0821/09 RJT Microbiology Laboratory Colonv Count 0 col/100mL SM209222B A (<200) 0820/09 SDI' 'rotalColiform 0 col/IOOmL SM209222B A (<1) 0820/09 SDP FecalCuliform 0 col/100mL SM20922213 A (<i) 0820/09 SUP RA lAM1 MYA ff�0. Ir ►R►Iw IIa�P AM YRY 7I1 w Vj SlmxY CSrFICArCN\\ssa� Prepared by �•• OF *�.� ROL'tert E. Johns, Jr. & Assoc. PLIFT MAN «IAw.A/wwM�/ 1P� ! Professional Land Surveyors rra�rrw+�+.n ►+1 (.� �. 17M MMII ORM loot �I wlr w `•rA� M 1� / Y Y ARU107Aa, AuitA M-504 ••�• R••�•• t Scale: T," 60, Roo. Lot S.F. R« plot no Ro. R7VMD a Aa. ftwArw, M Y Art a r a. rw r I Der vY.y 0-21-09 a••" 63r 1717 aKwoa ►sJMK rn rr�. w raM / r R T JR. a•...A r r.�r► . o.. r� .�.rL i norOro.n:" B-24-09 a"' 3438 tY.o 9193 MAL SIRUCTM AS -SLAT �`1y4f 21 �•,I L rw c ►Ap a. Row wr No I v'i�a y7:1'\ 1.1aa1 RAnnplbw: �'�"' `~►"'"` w1Vp. dl•�� IAt 4 Alcok G w.r•w Rarr r.r a,..w� r r.r w aro lw� /RRIa" Ip -m [:f115 f5 am aaMY SURVEY TYPE SYMBOLS R7R1DATg1 AS -alar • SCT RC3AR i° p AZQXZ A`.PMALT w"'a^"� A9"•`v 0 FCAMD RnAR w.DT /tA" ... AT..AM1I ... a01 vMT ... Tt700M1"T Y000 FiTltt ( COML7IEA e a>saeaT � 4-0 R�I$G �i t1� wwR11Nr71 RLC`. �f.-.-�. retk Fef.Ci ® .00O Oed PLOT PLAN5 X LOT SURVEYS OT IT n M wca►ON amLrtY OF TMC e"11-DCR CA OY.N[r.. ►RIOR m f1NlY 7?ICSS upf! J=dun A=J— CrC1'%z A::D vM:u *%.L sq CCkCMUCTIPA, TO KRIFY PROPCSED SUR.DMIO CAADC RSLATI%C I -,IWCN N II,Nry!1, W^.L�, �+!� CLLANp,'T7. SSS71.TUT 3. CF/%Ti71AYS. TO FT03NL0 GRAD[ ANO UTILITY COIINCOT/0NS AND TO DCWMMINC cm. ARS ww0wa IN r4l. APVRO]IMA7S LCCATICM. CNLY. S'NC1 C. THC WTZ7= CF ANY CA3UICM3, COKMANTS OR RC3TRIC7161S MAv OREMCMT SCVC IAIRWOvtMCMT1 rPCM W--.140SS^• AMC 1.tCA7^. Y'a.ICN 00 NOT AI►CAR ON THE WtCOROCD S'AVOC4NAION PLAY. ALL 019TANCCS MC NCC900 UNILLS! OTNRR rASC MOTTO. tRmol NO CPCVMSTANCU 3MCLU AM AS &XT DC U= ►OR CCMS74UCrIC4 Cot rpt CSTARUSIUNO WLWAIIY OR IPPea ulln r4 3URKYM TAM RESPCNStBUTY FCR 7Nr. •anAL TRANSACTIDM WY AND AVUMS FWA+CtAL UAKJ1V CNLY M plc CMT Cr TNC SL WY. USTCD DISTANCES Ii2VAa. OKR SCALIIMA. R(MpOUCTgN MAY rwtla [RRORS IN SCALE. Parcel I.D. 1. I,( VIA W11a(I(e2 Municipality of Anchorage i Development Services Department �•'�� Building Safety Division Onsite Water and Wastewater Program I ` 4700 South Bragaw St P.O. Box 196650 Anchorage, AK 99519-6650 www.ci.enchorage.ak.us (907) 343-7904 CERTIFICATE OF HEALTH AUTHORITY APPROVAL FOR A SINGLE FAMILY DWELLING 171.32 HAA Expiration Date: ,/ 2 L Z — D S INFORMATION I Complete legal description Lot 4. Block 6. Keno Hills Subdivision No. 5 Location site address or directions) _17815 Ashland Drive Current FIroparty owners) Jeff Gorton Day phone 3459105 Mailing address 17815 Ashland Drive. Anchorage AK 99516 Lending agency Day phone Mailin address Real Estate Agent Day phone Mailing Address Unless o erwise requested, HAA will be half by DSD for pickup. 1 2. NUMBE OF BEDROOMS: Four 4 1 3. TYPE O WATER SUPPLY: TYPE OF WASTEWATER DISPOSAL: Individ IndividL Iat Well ® Individual On-site al Water Storage I Community ❑ Individual Holding tank ❑ Class Well ❑ Community On-site ❑ Public 1 II Vater System ❑ Public Sewer ❑ The Municipality of Anchorage Development Services Department (DSD) Issues Certificatesbf Health Authority Approval (HAA) based only upon the representations given in paragraph 5 by an Independent professional civil engineer registered In the State of Alaska. Certificates of Health Authority Approval are requiro for the transfer of title (except b6tween spouses) for properties served by a single family on-site wastewater disposal and/or water supply system DSD also Issues HAAs upon request to homeowners. Certificates of Health Authority Approval are valid for 90 days from the date of Issue for properties served by a private or Class C well and may be reissued with new water sample results less than 30 days old. (Certificates may be reissued for a period of up to one year with valid water samples.) Certificates are valid for one year for properties served by Class A or B wells or a public water system. The Municipality of Anchorage is not responsible for errors or omissions In the professional engineer's work. 4. STATEMENT:OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, 1 verify that rn 1 Investigation, based on procedures outlined In the Health Authority Approval Guidelines for this application, shows that the on- site water supply and/or wastewater disposal system is(are) safe, functional and adequate for the number of bedrooms and type of structure Indicated herein. I further verify that based on the Information obtained from the Municipality of jAnchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disp,osal system Is(are) in compliance with all applicable Municipal and State code ordinances, ordinances, and regulations in effect at the time of installation. Name of Address Phone Engineer's Printed Name _Michael E. Anderson, P.E. Date _ :a 5. DSD SIGNATURE Approved for _ bedrooms. •ssi /:L•Clfif•Trf.7I HAA C Septic Well F 02 (I«. IZW) approval for bedrooms, with the following stipulations: A ow SITE WATER AND •: n'. AGER—r—= PRO RAM :• X Maintenance Agreements Advisory Supplemental Engineer's Report Other Original Certificate Date: 'I Legal A. WELL wen type Municipality of Anchorage Development Services Department Building safety Division On.Ske Water & Wastewater Program 4700 South Bragaw, SL P.O. Box 198050 Anchorage, AK 995198650 www.cLanchorage.ek.us (907) 343-7904 HEALTH AUTHORITY APPROVAL CHECKLIST If A. e, or C provide PWSID a _ Wen Log (1 Data comP�led 71211 4 Sanitary seal (Y" Y Wires property protected !(1'IN) Y Total depth 14Lft. Cased to , jLR Casing height (above ground) —B—In. FROM WELL LOO AT INSPECTION j Date of tm t 7@18004 Static wat�r level Z1 rt• R ! Well prod II _ 3 g.p.m. e,p� WATER SgMI PLE RESULTS: Coliform I colonleV100 ml.' Nitrate -tL mg.A. Other bacteria -L colonies/100 ml. Data of= iple: ➢1128005 Collected by. _ AH B. SEPTICAi )LDING TANK DATA Tank Type ftterhd SeoticMeel Date Installed 1-tIMM! Tank size gal. Number of Compartments a Clearouta (YIN) Y Foundation cleanout (Y/N) X Depression over tank (YIN) if High water alarm (YIN N Dab Of ping Pumper -Now construction C. ABSORPTION FIELD DATA Dab insfan 7118004 $oil rating (g.p.dA? or %Y/bdrm) 1.2QEM System type ode Trench Length IL Width 5 fk Gravel below pipe 4 It. Total depth IM R Eft absorption area AMfe Monitoring tube X Depression over field t( Date of ade quacy test Results (Pass/Fan) For _ bedrooms Fluid depth absorption field before teat _ in. Water added_ gal. New depth_ In. Elapsed The: _ min. Final fluid depth _ in. Absorption rate # g.p.d, Ilrlation Any reJwe Vestment (past 12 mo.) (YM S type) N If yes, give date D. LIFT STATION - Date installed 'Pump on' level at _ In. Datum E. SEPARATION DISTANCES Size In gallons 'Pump ofi level at _ lo. Cycles tested Manhole/Access (YIN) High water alarm level at Meets slam d dress SEPARATION DISTANCES FROM WELL ON LOT TO: Septi tanMifE atWn on lot MW On adjacent ids Absorption field on lot >tW On adjacent lots Public sewer main WA Public sewer manhole/deanout WA Sewer hhepou service one >25' Holding tank _NIA SEPARATION DISTANCES FROM SEPTICIHOLDING TANK ON LOT TO: Building foundation )f Property line _),I Absorption field >S Water main WA Water service One >1C Surface water XW Wells on adjeceet lots MW SEPARATION DISTANCE FROM ABSORPTION FIELD ON LOT TO: i Property line Air Building foundation Mir Water main Mg' Water Service l tie M(r Surface water MW Driveway, paddngNehide •forage >2S Curtain drain None Noted Wells on adjacent lots >1W F. COMMENTS G. ENGINEER'S CERTIFICATION I ca►tlfY Met I have determined through field inspections and review ofMunA*al recants Mat the above systems am in conformance with MOA HAA guidelines in effect on this date. Engineers Pdntm Name JA chsel E. Anderson. P.E. Date 9t2glgS I HAA Fee $ Date of Payment 4 f AS Waiver Fee $ Date of Payment z 30 x N a 76-30 KENO HILLS SUED., ADDN. NO. 5 LOT 4, BLOCK 6 2.40 ACRES N 89055'15"E 374.22' GASTALDI LAND SURVEYING, LLC JEFF A. GASTALDI, R.L.S. 4726 WEST 88TH AVENUE ANCHORAGE, ALASKA 99502 PHONE 248-5454 IGRID 3438 103/1/2005 I BUILDING DETAIL SCALE. 1 "=20' I HEREBY CERTIFY THAT 1 HAVE SURVEYED THE PROPERTY DEPICTED ABOVE AND THAT NO ENCROACHMENTS EXIST EXCEPT AS INDICATED. IT IS THE RESPONSIBILITY OF THE OWNER TO DETERMINE THE EXISTENCE OF ANY EASEMENTS, COVENANTS OR RESTRICTIONS WHICH DO NOT APPEAR ON THE RECORDED SUBDIVISION PLAT. UNDER NO CIRCUMSTANCES SHOULD ANY DATA HEREON BE USED FOR CONSTRUCTION OR FOR ESTABLISHING BOUNDARY OR FENCE LINES. ANCHORAGE RECORDING DISTRICT, ALASKA F.B. JOB NO. 05-02 KHS546 I NOTE: NO CORNERS SET THIS DATE. 111=50' AV �. •' 'f � 9 w49TH.* 0 ..• .................41F P • Jeffery aetaldi ; AV �� •. LS -6091 °^ : Ao . B^BO' p ••........ yJ.I a royeeoional LI Ole 09-20-05;11:16 ; r SGS Ref. #: Client Name: Project Name: Client Sample ID: Matrix: PWStD Sample Remarks: 1055929 Anderson Engineering Keno Hills No 5, L4, B6 Keno Hills No 5. L4, B6 Drinking Water :907 561 5301 SGS Environmental Services Inc 200 W. Potter Drive Anchorage, AK 99518 Tel: (907) 562-2343 Fax. (907) 561-5301 Ali dates/times are Alaska Standard Time Printed DateMme: 09/20/05 11:10 Collected DateMme: 09/12/05 10:50 Received DateMme: 09/12/05 11:15 Technical Director. Stephen Ede/% Allowable Prep Analysis Parameter Results PQL Units Method Limits Date Date Init Bacteria 0.00 9222B 09/12/05 09/12105 if Nitrate 1.20 0.10 mglkg EPA 300.0 10.00 09/12/05 09/12/05 mx