HomeMy WebLinkAboutGREENBROOK BLK 2 LT 7Greenbrook
Block 2
Lot 7
#017-023-59
Municipality of Anchorage
On-Site Water and Wastewater Section • (907) 343-7904 Page of
ON-SITE WASTEWATER INSPECTION REPORT
Permit Number: OSP241349 PID Number: 017-023-59
Dwelling: ® Single Family (SF) ❑ with ADU ❑ Duplex (D) ❑ Two Single Family Project: ❑ New ® Upgrade
Name
AMY &JOHN DELESLINE
ABSORPTION FIELD
❑ Deep Trench ® Wide Trench ❑ Bed ❑ Mound
Site Address
12840 VON SCHEBEN DRIVE, ANCHORAGE
❑ Other
Phone
Number of Bedrooms
Soil Rating
Total depth from original grade
4
0.45 GPD/SF
6 Ft.
LEGAL DESCRIPTION
Depth to pipe invert from original grade
3 Ft.
Gravel depth beneath pipe
3 Ft.
Subdivision Block Lot
GREENBROOK 2 7
Fill added above original grade
VARIES 0.3'- 0.6 Ft.
Gravel length
160 Ft.
Township Range Section
Gravel width
5 Ft.
Beds: Number of Lines
Distance between lines
Ft.
SEPARATION DISTANCES
TO SepticAbsorption
Lift Statin
Holding Sewer
Total absorption area
Number of trenches
Dist. between trenches
From Tank Field
Tank Line
1379 Ftp
4
(PER CODE & MOA) 6+ Ft.
Well-- 1 QQ'+
25'+
TANK Il Septic [IS.T.E.P. E]Holding ElOther
Manufacturer
EXISTING
Capacity
Gal.
Surface Water -- 100'+
(
Material
Number of compartments
j
Lot Line 1 -- 101+
NA
Foundation-- 1 Q'+
LIFT STATION
Manufacturer
Capacity
Gal.
Remarks Existing field decommissioned. Existing septic
tank integrity verified.
Alarm location
Electrical installed by
PIPE MATERIAL House to tank Tank to 3034
drainfield
Installer Mike N Anderson, PE (MNA)
_
Drainfield 3034 CO/MT 3034
Inspector FWC & MNA
BENCH MARK (Assumed elevation) 100 ft
Inspeection 1s` 11/06/2024 2nd 11/06/24
Location and description
3`d 11/07/24 41h 11/08/24
BOTTOM CORNER OF SHED
ON-SITE WATER AND WASTEWATER SECTION APPROVAL
OF A
Conditional Approval: Date
l
f " ' • " " " : "
C
�F••• CE 12 991 n .•�`�%
���c���R•.,I1/13/24..•�C�i
Septic Syste
Approved /
_ Date 1 /
.,
ri
~
\ PROFESS0kW -
ote: this approval does not include well permit requirements.
(Rev 05//18)
S 87°25'12''E 302.68
a
s
p
h
a
l
t
D
R
I
V
E
W
A
Y
4-BR
HOUSE
W
O
O
D
W
A
L
K
W
A
Y
DE
C
K
37.0
2
2
.
6
FIRST WATER CONSULTING
PID:017-023-59 PERMIT:OSP241349
GREENBROOK BLOCK 2, LOT 7
MUNICIPALITY OF ANCHORAGE
On -Site Water & Wastewater Program
PO Box 196650 4700 Elmore Road
Anchorage, Alaska 99519-6650 Phone: (907) 343-7904 Fax: (907) 343-7997
http://www.muni,org/onsite
On -Site Wastewater Disposal System Permit
Permit Number: OSP241349
Work Type: Septic Upgrade
Tax Code Number: 01702359000
Site Legal Address: GREENBROOK BLK 2 LT 7 G:2839
Site Mailing Address: 12840 VON SCHEBEN DR, Anchorage
Owner: DELESLINE AMY & JOHN DAVID
Design Engineer: FIRST WATER CONSULTING
This permit is for the construction of:
Effective Date:
Expiration Date:
Lot Size in Sq Ft:
Total Bedrooms:
10/16/2024
10/16/2025
52137
Q Disposal Field ❑ Septic Tank ❑ Holding Tank ❑ Privy ❑ Private Well ❑ Water Storage
All construction shall be in accordance with:
1. The attached approved design.
2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska
Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80)
3. The wastewater code requires inspections during the installation. The engineer shall notify the Development
Services Department per AMC 15.65. Provide notification by calling (907) 343-7904 (24/7).
4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather
shall be either:
a. Opened and Closed on the same day, or
b. Covered, sealed, and heated to prevent freezing
- Reeey y: 5 y &t e j fid /15"'�5 Ooc%e
Issued By:
Date:
Date:La I Zq
4
MUNICIPALITY OF
Development Services Department
On -Site Water & Wastewater Section
Parcel I.D. 017-023-59
ANCHORAGE Rosk
ON-SITE SEPTIC/WELL PERMIT APPLICATION
Property owner(s) DELESINE AMY & JOHN DAVID Day phone
Mailinq address 12840 VON SCHEBEN DRIVE, ANCHORAGE, ALASKA 99516
Site address 12840 VON SCHEBEN DRIVE, ANCHORAGE, ALASKA 99516
Legal description (Sub'd., Block & Lot) GREENBROOK B2, L7
Legal description (Township, Range & Section)
Lot Size 52,137 Sq. Ft. Number of Bedrooms
M
Phone: 907-343-7904
Fax: 907-343-7997
APPLICATION IS FOR:
APPLICATION IS AN: TYPE OF DWELLING:
(N all that apply)
Absorption Field
Initial El Single Family (SF)
(w/wo, ADU)
Septic Tank
E]
Upgrade
Duplex (D) ❑
Holding Tank
❑
Renewal
Multiple Dwellings ❑
Privy
❑
(SF and/or D)
Private Well
❑
Water Storage
❑
THIS APPLICATION INCLUDES A WAIVER REQUEST FOR:
Distance:
I certify that the above information is correct. I further certify that this is in accordance with
applicable Municipal Codes.
(SignAfOeq , of''rt-
pi�qpe y owner or authorized agent)
Permit/Rush Fees: . 5q 5 3 73 -
Date of Payment: 1 a11'4'Zq
Receipt Number:.?- I 11) '1
Permit No. 0,51029 1:3 q 9
Waiver Fees:
Date of Payment:
Receipt Number:
Waiver No.
GADevelopment Services\Building Safety\On Site Water and WastewaterTormsUient FormsTermit Application.doc
13030 Sues Way, Anchorage, AK 99516
907-350-9566 / firstwaterAK@gmail.com
!
!!
October 10, 2024
Municipalities of Anchorage
On-Site Water & Wastewater Program
4700 Elmore Road
Anchorage, AK 99507
RE: SEPTIC SYSTEM UPGRADE PERMIT
LEGAL: GREENBROOK BLOCK 2, LOT 7
The property owner has requested we obtain a permit to upgrade the failed septic system of the
above referenced lot. We propose to install 4 shallow trenches per the attached design to serve
the existing 4-bedroom residence. The design is based on the recent test hole conducted on
October 2, 2024. Groundwater was observed at test hole excavation and at monitoring. Due to
this monitoring of groundwater at 10.5’ from grade and proximity to the existing field with a
total depth of 11’ from grade, this existing field will be abandoned in place.
The slopes are moderate at 8-13% at the proposed upgrade location. The lot and area are served
by public water. The design will not impact any of the neighboring properties. Please contact us
if you have any questions.
Sincerely,
Curtis Huffman, P.E.
Municipality of Anchorage
On-site Water and Wastewater
REVIEWED FOR CODE COMPLIANCE
OSP241349, Deb Wockenfuss, 10/16/24
S
0
°
0
2
'
1
9
'
'
E
1
4
2
.
7
2
'
S 89°00'00''W 296.25'
S
2
°
45
'
00
"
'
'
W
1
6
5
.
2
0
S 87°25'12''E 302.68
L
=
4
1
.
1
3
D
R
I
V
E
W
A
Y
SHED
4-BR
HOUSE
WO
O
D
W
A
LK
W
A
Y
D
E
C
K
D
E
C
K
VO
N
S
C
H
E
B
E
N
D
R
I
V
E
10
'
U
TI
LI
TY
E
A
S
E
M
E
N
T
67.5
25
'
+
-
52
.
0
3 7.0
2
2
.
6
7.0
29
.4
29.9
FIRST WATER CONSULTING
GREENBROOK BLOCK 2, LOT 7
DESIGN CALCS:
NO WELLS WITHIN
200' OF PROPOSED
SEPTIC SYSTEM.
NO SLOPES >25% WITHIN 50'
OF PROPOSED FIELD.
AREA SERVED BY
PUBLIC WATER.
Municipality of Anchorage
On-site Water and Wastewater
REVIEWED FOR CODE COMPLIANCE
OSP241349, Deb Wockenfuss, 10/16/24
S 87°25'12''E 302.68
D
R
I
V
E
W
A
Y
SHED
4-BR
HOUSE
W
O
O
D
W
A
L
K
W
A
Y
D
E
C
K
D
E
C
K
25
'
+
-
5
2
.0
3 7.0
2
2
.6
7.0
2
9
.
4
29.9
FIRST WATER CONSULTING
DESIGN DETAILS:
GREENBROOK BLOCK 2, LOT 7
Municipality of Anchorage
On-site Water and Wastewater
REVIEWED FOR CODE COMPLIANCE
OSP241349, Deb Wockenfuss, 10/16/24
13030 Sues Way - Anchorage, Alaska 99516
Tel. 907-350-9566 firstwaterAK@gmail.com
SOILS LOG - PERCOLATION TEST
LEGAL DESCRIPTION: GREENBROOK B2, L7
PERFORMED BY: FWCS / FWC - I CURTIS HUFFMAN CERTIFY THAT THIS TEST WAS PERFORMED IN
ACCORDANCE WITH ALL STATE & MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE. DATE: 10/09/2024
DEPTH
FEET OG
SOILS
1
ORG/OL/ML
2
3
4
5
6
7
8
SM/ML
9
10
11
12
SEEPS
13
14
15
16
17
ML
18
19
BOH
20
Reading Date Gross
Time
Net
Time
Depth to
Water
Net Drop
10/08/24 30 min 6” 0 11/16”
30 min 6” 0 11/16”
30 min 6” 0 11/16”
PERCOLATION RATE 44 (MIN / INCH)
TEST RUN BEWTWEEN 6 & 7 FT
PERC HOLE DIAMETER 6”
PRE-SOAKED PRIOR TO TEST & ALL READINGS TO
THE 1/16TH.
GROUND WATER ENCOUNTERED: YES - SEEPS
IF YES, AT WHAT DEPTH: 12’
DEPTH TO WATER AT MONITORING: 10.5’
DATE: 10/09/2024
TESTHOLE # 24-1 DATE PERFORMED: 10/02/24
SEE SITE PLAN FOR SLOPE & LOCATION
COMMENTS:
VERIFY GROUNDWATER MT
AT TIME OF CONSTRUCTION
PERFORMED FOR: JOHN & AMY DELESLINE
10/09/2024
Municipality of Anchorage
On-site Water and Wastewater
REVIEWED FOR CODE COMPLIANCE
OSP241349, Deb Wockenfuss, 10/16/24
Municipality of Anchorage _
Development Services Department
I� Building Safety Division r .
�, ��
On -Site Water 8 Wastewater Program, 4700 South Bragaw St. :
P.O. Box 196650 Anchorage, AK 99519-6650
www.ci.anchorage.ak.us (907) 343-7904 Page 1 of 3
Onsite Wastewater Disposal System and/or Well Inspection Report
Permit Number. SW030453 PID Number. 017-023-59
Name: Wastewater System: ❑ New ■ Upgrade
JOHN McCONNAUGHY
Address:
ABSORPTION FIELD
12840 VON SCHEBEN DRIVE ' ANCHORAGE, AK 99508
Phone: No. of Bedrooms:
(907) 333-1235 4
N Deep Trench a Shallow Trench O Bed 0Mound OOther
LEGAL DESCRIPTION
Sal Ra4rq:
0.6 GPa/sR. R
iolel a.PtA hem plpinel eroew
11 (MAX) R
Block: Lot: Subdivision:
a.Mh to Pb• ealem hem cd0d eras:
GnwW dWh beneath pip.:
8.52
2 7 GREENBROOK
2.48 R
R
Township:—Range: Section: —
rll ma.a sew+ erlpind eras.:
Gry W NrgN:
59
—
SEE DWG. R
R
Gaw wW .
NurM.r N an.e:
D41aww k.b«n tMn.:
WELL: O New ❑ Upgrade
2.5 R
1
— R
Ck,"f4o. Pdrat.. A.B.G :Ce.W
To:
Tocol oe.orpUen ano:
1003
F$i a nip1 :
D 3034/ F-810
UN\� n
R
so. R
tet. X12/2-3/2003
orw.r. GpMM wt. a"l"e:
s"�` wm.r L««:
YM10A+ HOME SERVICES
R
Pu" Sot ALCasks
Height Ae croons:
TANK
CPN
R
R
SEPARATION
DISTANCES
■septic aHolding as.T.E.P. 0Other
Septic
Absorption
Field
Uft
station
Holding
Tank
lc/PdWt.
sewer Un«
VionwlTo
OCAN
ANCHORAGE TANK
��� In p�ww.
1250
From
Tank
w oemvedn•n..
Well
200'+
200'+
—
—
25'+
STEELS
2
Surface water
100'+
100'+
—
—
—
LIFT STATION
5re ti gauorw:
Nanufectwer:
Lot Une
5'+
10'+
—
—
—
'
an k«.l at: vol at.
Hkih woNr alarm et:
Foundation
5'+
10'+
—
—
—
Punp Nob
a.cb4al ewp.aaone p.nomwe Iry:
Curtain Drain
NONE
KNOW
Remarks: OLD SEPTIC TANK AND DRAINFIELD
BENCH MARK
tAOahan ane o..adpuara
COMPLETELY ABANDONED.
TOP OF CONCRETE SLAB AT GARAGE DOOR
1q1.58 R
ENGINEER'S SEA(
qOQ�
oa 4�
AKWWC INC. 12/2/2003
Inspections performed by: r Dates: 1st•••
12/2/2003
..
2nd
3rd 12/3/2003
... .: Gar ess:'
Development S ices Department Approval
�OO� J� ., c 7953 ••'q`FO�
E,
��^00'Professlo"o,
Reviewed and approved by: Date: Z�'
(Rev. "l)
PERMTTNUMBER: AS -BUILT DRAWING P017 0 NUMBER:
SWO
SW030453 017-023-59
APPROXIMATE KEY I
BOX LOCATION
APPROXIMATE LOCATION
OF WATER UNE\\\
_
� I
A B LL,
i —
STI 130.56 18.57 % p
ST2 34.50 26.63 II_..._.
DBLt 36.25 29.84 %//r. EXISTING%:':�, L
DBL2 37.19 30.68 /% 4 BEDROOM
G� HOUSE :;1 LLJ
C01 106.25 81.55
MT1 104.85 80.10O/ q • : U
NEW 1250 GALLON �/B ��•:•!', DBLI fJ7
CO2 79.98 43.27 SEPTIC TANK •`s <.J..•
MT2 82.32 46.34 : •;•:!; Z
cot 51 �` ': • DBL2 O
MT2 I ; �� EXISTING SEPTIC SYSTEM
II 512_x:• ABANDONED IN PLACE
8 II TTH/1 •?tip• ,.:�-`----" I
I
NEW 11 1
11 ' 1110N
12/11/2003
DRAWN BY:
•• :7S14�I
AI.ASRA «'Xrr,,R S WASTEWATERSSE
M.E.W
Qp I
CONSULTANTS. INC.
1 ^ = 40'......
.. .. .... • ......
A0F TUDOR GOeJ. SURF Ifl pvfwOcnGF pK 995C) R•ONF 190)11p.61)9 • FAX (oN).9A3)4M1
..... .......
Q of A. Gar ess.-'
QQO•Pa 79 .•. FFG
PREPARED FOR: PHONE NUMBER:
JOHN McCONNAUGHY (907) 333-1235
PAGE NUMBER:
2 OF 3
LEGAL DESCRIPTION:
GREENBROOK SUBDIVISION; LOT 7, BLOCK 2,
00 ••.,.•,•,..•'�,o
4���Z%m;-000
TrvAS
BUILT DRAWING OF SEPTIC SYSTEM UPGRADE
PERMIT NUMBER:AS-BUILT DRAWING PARCEL ID NUMBER:
SW030453 017-023-59
FINAL GRADE
100.00-101.16
TOP OF TANK AT STIS 2
INLET 96.97--\ F TANK AT n-/�T - 95.99
THJ1
INVERT OF BUNG
AT INLET - 95.39
FINAL GRADE
97.02 (AVO.)
ELEVATION OF
ATER - 79.32
NEW 1250 GALLON
SEPTIC TANK
FABRIC
INVERT OF PIPE
93.01 (AVG.)
"TOM OF TRENCH
. 61.52 (AVG.)
NERT OF BUNG AT
OUTLET . 95.21
Ll—O— RELATIVE ELEVATION OF BOTTOM
OF TEST HOLE - 78.02
DATE:
/) 12/11/2003
F l /f1 I I'� DRAWN BY.
ALASKA IN IT'R & `VASTL«'ATLR SCALE-' G./A.J.G.
CONS_ LTANTS• INC.—s---��� N.T.S.
370. F TUDOR ROAD. SUIT- 10. • ANr.ORAGF AK 00507 • F ONF (907)117-179 • FAX (007MR-Mb
PREPARED FOR: PHONE NUMBER: PAGE NUMBER:
JOHN McCONNAUGHY (907) 333-1235 1 3 OF 3
LEGAL DESCRIPTION:
GREENBROOK SUBDVISION; LOT 7. BLOCK 2
TYPE OF WORK:
PROFILE AS—BUILT DRAWING OF SEPTIC SYSTEM UPGRADE
,9
........ . .........:... �
. ............
f A. Orn ss.. OHO
C —79 :p
io°or •' �d0
�il... eCQv�
MUNICIPALITY OF ANCHORAGE
Development Services Department
On -Site Water & Wastewater Program
4700 South Bragaw Street
P.O. Box 196650, Anchorage, AK 99519-6650
(907) 343-7904
ON-SITE WASTEWATER DISPOSAL SYSTEM PERMIT
Upgrade
Permit Number: SW030453
Legal Description: GREENBROOK BILK `2_L_T-7,'
Design Engineer: 0041 AK Water & Wastewater Consultam
Owner Name: John McConnaughy
Owner Address: 12840 VON SCHEBEN DRIVE
ANCHORAGE. AK 99508 -
Iz) zj 03-� pm
P
Date Issued: Oct 22, 2003
Expiration Date: Oct 21, 2004
Parcel ID: 017-023-59
Site Address: 012840 VON SCHEBEN DR
Lot Size: 52137 SO. FT.
Total Bedrooms: 4 Permit Bedrooms: 4
This permit is for the construction of:
❑✓ Disposal Field ❑✓ Septic Tank ❑ Holding Tank ❑ Privy
All construction must be in accordance with:
1. The attached approved design.
❑ Private Well ❑ Water Storage
2. All requirements specified In Anchorage Municipal Code Chapters 15.55 and 15.65 and the State of Alaska
Wastewater Disposal Regulations (18AAC72 ) and Drinking Water Regulations ( 18AAC80 ).
3, The engineer must notify DSD at least 2 hours prior to each inspection. Provide notification by calling
(907) 343-7904 ( 24 hours ). ( Not required for a Water Supply Permit only).
4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather
must be either: A. Open and closed on the same day.
B. Covered, sealed, and heated to prevent freezing.
Received By.
Issued By.
Date: 10-4-03
Date: 10 2 ZQ3
Municipality of Anchorage
• Development Services Department
Building Safety Division
On -Site Water & Wastewater Program
4700 South Bragaw St.
P.O. Box 196650 Anchorage, AK 99519-6650
www.ci.anchorage.ak.us
(907) 343-7904
ON—SITE SEWER/WELL PERMIT APPLICATION
FOR A SINGLE FAMILY DWELLING
Parcel l.D. (�� �Z3 vl Permit Number 5tVQ30453
Property owner(s) JOHN McCONNAUGHY Day phone 333-1235
Mailing address (1) 4219 SAN ERNESTO AVENUE APRT J4 ' ANCHORAGE. AK
Mailing address (2) Zip Code 99508
Legal description (Lot, Block & Sub'd.) LOT 7 BLOCK 2• GREENBRO`OK/ SUBDMSION
Legal description (Section, Township & Range) 147* I a%"O V 0)'1 SIJ V_—A'n r
Lot Size 5; 71 Acresq.Ft. Number of Bedrooms 4
THIS APPLICATION IS FOR:
Sewer Only ❑ Well Only ❑
Sewer and Well ❑ Water Storage ❑
Sewer Upgrade N
THIS PROPERTY CONTAINS:
Hot Tub ❑ Jacuzzi ❑
Swimming Pool ❑ Water Softening Unit ❑
Therapy Pool ❑
I certify that the above information is correct. I further certify that this application is being made for a
Single Family Dwelling and is in accordance with applicable Municipal codes.
ALASKA WATER & WASTEWATER CONSULTANTS INC.
Permit Fees: 4-400
Date of Payment: 10.11.03G
Receipt Number:��5-
Waiver Fees*
Date of Payment:
Receipt Number:
ALASKA WATER & WASTEWATER
.�I CONSULTANTS, INC.
September 12, 2003
Municipality of Anchorage
Development Service Department
Building Safety Division
On -Site Water & Wastewater Program
P.O. Box 196650
Anchorage, Alaska 99519-6650
Ref: Septic System Upgrade for Lot 7, Block 2, Greenbrook Subdivision
To whom it may concern:
The existing 4 bedroom house is served by a community water system and a private septic
system. The existing septic system is in a state of failure and needs to be upgraded. A test hole
was dug on the property. The drainfield will be designed around the 30 foot radius of this test
hole. We are proposing that a new 1250 gallon septic tank and a deep trench type drainfield be
installed. Comments regarding the design are summarized as follows:
1. SOILS: See the attached log which shows the soil classifications, groundwater monitoring,
and the percolation test results. It is our opinion that due to the overall appearance of the soils, an
application rate of 0.6 gallons/day/ft2 should be used.
2. TRENCH DESIGN:
a.
Percolation Rate: 18.5 minutes/inch
b.
Proposed Application Rate: 0.6 gallons/day/112
c.
Number of Bedrooms: 4
d.
Design Flow: 600 gallons per day
e.
Minimum Absorption Area: 1000 R2
f.
Total Depth: 11 feet (max.)
g.
Effective Depth: 7.5 feet
h.
Width: 2.5 feet
i.
Reduction Factor: N/A
j.
Minimum Length: 67 feet long
k.
Effective absorption area = 1005 fl?
3. SURFACE WATERS: There are no surface waters within 100+ feet of proposed septic
upgrade. In short there are no surface water concerns.
3701 E. Tudor Road, Suite 101 • Anchorage, AK 99507
Ph: (907) 337-6179 • Fax: (907) 338-3246 • Website: akwwc.com
4. TOPOGRAPHY: As can be seen on the attached topography site plan, the average
topography in the area of the proposed drainfield is a 5 to 10 percent slope running
approximately east to west. In short, there are no slope concerns.
I am unaware of any adverse impacts this installation would have on adjacent wells or septic
systems. If you have any questions, please contact us at 337-6179. Thank you for your
accict.qnrP
M.S.
NOTE. Attached is a site plan drawing, a design drawing, a topography site plan, a soils log,
and a 7 page construction specification letter which are all part of the design package for this
septic system.
3701 E. Tudor Road, Suite 101 ' Anchorage, AK 99507
Ph: (907) 337-6179' Fax: (907) 338-3246' website: akwwc.com
\
I
\\\ \\\
CREENSROOK S/D;
\ \
LOT D, BLOCK 2,
\ \
I
\
\ \
I
OTE: ALL PROPERTIES 1
\
SHOWN SERVED BY I
COMMUNITY WATER
\
i
SYSTEM I
I
CREENBROOK S/D;
I
'
I
I
LOT B. BLOCK 2,
GREENBROOK S/D;
I
LOT 7, BLOCK 1, I
I I
EXISTING
1 I
i
4 BEDROOM
1 I
HOUSE I
PROPOSED SEPTIC UPGRADE I
I
(SEE DESIGN PACE 2 OF 2) I
I
I
1
I 1
1
I
EXISTING C I
SYSTEM I
1
I 1
1
I
I
GREENBROOK S/D;
/1
-c •�
I
LAT 12A, BLOCK 2. I 1
I I
I I
1
I
I
I
I 1
I
I
I
CREENBROOK S/D; j
LOT 8, BLOCK L,
I I
' I
W
> '
I
CREENBROOK S/D;
LOT 6, BLOCK 2,
O I
W
W'
I
I
Z/
I
1
GREENBROOK S/D;
/
CREENBROOK S/D;
2 1
LOT S, BLOCK 1,
LAT 5, BLOCK 2.
O I
I
I
DATE:
9/12/2003
•...
��� .... �I (1 .�1�.
DRAWN BY:
C.J.G.
_
ALASKA WATER & WASTEWATER
4 4"
CONSULTANTS,
INC.
SCALE
1" = 100.
;'. !`.:...... ....... ....:.°.%1i
,lm c TNnOP PmAy G. IITc "I . AN!'vAQAfc pc OOCOI � V„Mlc (0nlll�l.A-70 . PAX IONMA.}71.w
........
PREPARED FOR PHONE NUMBER:
PAGE NUMBER:
JOHN McCONNAUGHY
333-1235
1 OF 2
y; if Carne S.:
Dy • — 3
'•
LEGAL DESCRIPTION:y�+�
GREENBROOK SUBDIVISION; LOT
7, BLOCK 2,
............
�.l
.......•• cp =
z4"
TYPE OF WORK:
�ofesslo0a
SITE PLAN FOR SEPTIC SYSTEM
UPGRADE
`• .^.nn
PROPOSED DRAINFIELD. EXCAVATE A
TRENCH THAT IS 11 FEET DEEP
MAXIMUM BY 2.5 FEET WIDE BY 67
FEET LONG. ADD 7.5 FEET OF CLEAN,
WASHED SEWER DRAINROCK.—
NEW 1250 GALLON
SEPTIC TANK -
NOTE: THE CONTRACTOR SHALL HAVE THE
SOUTH LOT LINE FLAGGED BY A REGISTERED
LAND SURVEYOR PRIOR TO CONSTRUCTION.
�AlASKA WATER S WASTEWATER
CONSULTANTS, INC.
X701 F TUDOR ROAD $MTF 101 • AWMORAfF AA ROSO? • Re f (001)117.6170 • FAX f00))338171E
2EPARED FOR: PHONE NUMBER:
JOHN MGCONNAUGHY 333-1235
.GAL DESCRIPTION:
GREENBROOK SUBDIVISION; LOT 7, BLOCK 2,
PE OF WORK:
DESIGN DRAWING OF PROPOSED SEPTIC UPGRADE
•••'•' INSTALL DOUBLE I
.:':. CLEANOUT
-EXISTING DRAINFIELD TO BE USED
AS A RESERVE SITE IF GRAVITY
FLOW CAN BE ACHIEVED.
TALL ROW
DIVERTER
9/12/2003
AWN BY:
C.J.G.
ALL,
1" = 40• .............
GE NUMBER:
2 OF 2 QQ '•: eff G ess.:
Q4°y,J E 7953 •'' `F`e'
Ld
>I
G_
0
Y APPROXIMATE KEY
Z
BOX LOCATION
Ld
ml
w
APPROXIMATE LOCATION
OF WATER UNE
(n I
ZI
i
z
I
i
F-T-��
I
EXISTING
4 BEDROOM
HOUSE EXISTING SEPTIC TANK TO
BE COMPLETELY ABANDONED
PROPOSED DRAINFIELD. EXCAVATE A
TRENCH THAT IS 11 FEET DEEP
MAXIMUM BY 2.5 FEET WIDE BY 67
FEET LONG. ADD 7.5 FEET OF CLEAN,
WASHED SEWER DRAINROCK.—
NEW 1250 GALLON
SEPTIC TANK -
NOTE: THE CONTRACTOR SHALL HAVE THE
SOUTH LOT LINE FLAGGED BY A REGISTERED
LAND SURVEYOR PRIOR TO CONSTRUCTION.
�AlASKA WATER S WASTEWATER
CONSULTANTS, INC.
X701 F TUDOR ROAD $MTF 101 • AWMORAfF AA ROSO? • Re f (001)117.6170 • FAX f00))338171E
2EPARED FOR: PHONE NUMBER:
JOHN MGCONNAUGHY 333-1235
.GAL DESCRIPTION:
GREENBROOK SUBDIVISION; LOT 7, BLOCK 2,
PE OF WORK:
DESIGN DRAWING OF PROPOSED SEPTIC UPGRADE
•••'•' INSTALL DOUBLE I
.:':. CLEANOUT
-EXISTING DRAINFIELD TO BE USED
AS A RESERVE SITE IF GRAVITY
FLOW CAN BE ACHIEVED.
TALL ROW
DIVERTER
9/12/2003
AWN BY:
C.J.G.
ALL,
1" = 40• .............
GE NUMBER:
2 OF 2 QQ '•: eff G ess.:
Q4°y,J E 7953 •'' `F`e'
SEPTIC UPGRADE
N PAGE 2 OF 2)
)OK S/D:
BLOCK 2,
I 1 6
Ll
F T%v+o C: •n9 k.nTP Ali • ANrwPongP nF 00.07
r' ED FOR ���
OHN MCCONNAUGHIL_
WDESCRIPTION:
REENBROOK SUBDIVISION; LQ
OF WORK:
SITE PLAN FOR SEPTIC SYSTEI
LOT 3,
D,
0
I Co -"To (-S'
WATER
4 BEDROOM
HOUSE
IXISTINCSEPTIC
SYSTEA
GATE �
9/,Po),z 0
4p
� . • •' ..
Opp
S
DRAWN BY: -
p
/
p • nY f00T}LP. VI.n
�.. •. �.. .D
T. ......p
E 5 .p
0
04od 1.1 eio oa o
•ore
1
ER:
PAGE N MBER•
2
2.
1
ALASKA
N'E'ATER & WASTEWATER
G, •\ 9 d
yp�
S'..,-.
CONSULTANTNC.
s •
SOIL LOG - PERCOLATION TEST
.. ..
...........
LEGAL DESCRIPTION:
GREENBROOK SUBDMSION; LOT 7, BLOCK 2
O •• of a A.
OQQ�' f•'• —7
Go ness:
a
PERF?O�RMED FOR:
4 3 8'
JOHN McCONNAUGHY • 9 5
DATE. / /2003
4����4000��00000
••' SFO
(f e`)
= ==
TEST HOLE 1
1 =_==�
ORGANICS
SOIL CLASSIFICATIONS
2
RED
r
LOAM GW -_ ORG
3
r=: GP ML
GM CL
4
GC OL
". •°. o SW MH
5
SP CH
s
SM ' i OH
p
6
SC
7
DEPTH TO DATE
GROUNDWATER
8
DRY 9/2/2003
16.2' 9/9/2003
9
SITE PLAN
1100'
10
SM
CLOCK NET TIME
WATER LEVEL
NET DROP
11
DATE READING
TIME (MINUTES)
READING
(INCHES)
9 5 2003 1 1:16 -
6"
—
12
2 1:46 30
4 1/4-
1 3/4-
13
3 1:47 —
6'
—
4 2:17 30
438"
1 58'
14
5 2:17 —
15
16
17
B.O kl.
18
PERCOLATION RATE 18.5 (MIN./INCH) PERC.
HOLE DIA.
6 (INCHES)
19
TEST RUN BETWEEN 7.0 FT. AND 8.0
FT.
20
A FOUR HOUR PRESOAK WAS PERFORMED: N YES [-]NO
SOILS LOGGED
BY:
SUSAN OSWALT PERCOLATION TEST PERFORMED BY:
SUSAN OSWALT
COMMENTS:
PERFORMED
BY AKWWC, INC. I, JEFFREY A GARNESS, CERTIFY THAT THIS WA
P RFORMED IN ACCORDANCE
WITH ALL STATE
AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE:
6
2:47
30
4 3 8'
1 5 B"
�\ MUNICIPALITY OF ANCHORAGE
\l DEPARTMENT OF HEALTH &ENVIRONMENTAL PROTECTION
• ar�
ENVIRONMENTAL ENGINEERING DIVISION
\, 825 L Street • Anchorage, Alaska 99501 Telephone 264.4720
ONSITE SEWAGE DISPOSAL SYSTEM AND/OR WELL INSPECTION REPORT
NAME
a t- Q(- G
PHONE
NEW
UPGRADE
MAILING ADDRESS
LEGALDES IPTION
r C
LOCATION
M«ll �Gve t .
NO.OF BEDROOMS
DY
DISTANCE TO:
Well
Absorption area
Dwelling
PERMITO. N
s-2Manulxturer
w
`r
A
Mate al
iC G
No of compartments
w
Liq. capati in allons
IF HOME DE:
Inside length
Width
Liquid depth
d le
Jv2
DISTANCE TO:
Well
Dwelling
PERMIT NO.
_? F
Manufacturer
Material
Liquid capacity in gallons
O
w=
DISTANCE TO:
Well
Foundation
Nearest t line
PERMIT NO.
J LL E
f ? W
No. of lines/
Length of each line
Total length f Ines
Trench width
inches
Distance between lines
H
o
Top of the to finish grade
Material beneath Zile
VilUL� inches
Total effective absorption area
SV
W
Length
Width
Depth
PERMIT NO.
Q H
W�
Type of crib
Crib diameter
Crib depth
Total effective absorption area
w
DISTANCE TO:
Well
Building foundation
Nearest lot line
.r
Class
Depth
Driller
Dntance to lot line
PERMIT NO.
DISTANCE TO:
Building foundation
Sewer line
Septic tank
Absorption areafsl
OTHER
TO
PIPE MATERIALS �//''
P,�/ V.
SOIL TEST RATING AA _
INSTALLER [
SCsI
REMARKS
13,
_
HOVE DATE ry LEGAL
724** ( ev.3/79!'-
w rl L l rJ 10 I F1; i t> I T'rm O F Fi rJ C Ij.p Fy In
iG E
-� DEPARTMENT r' HEALTH AND ENVIRONMENTAL tOTECTION
-AllR 825 '� STREET. ANCHORAGE, AK. 99..501 S_ 4irzo
01" !3v _
264-4720 c7
OtJ— I TE SEWEFR F='EFRM I T
PERMIT NO. ( 810152 ) 0i s !�. lt.l_g'l a/ U
APPLICANT
LOCATION
LEGAL
I un
GEORGE HARRISON Ur SRA BOX 3738 ANCH. Ad. � tw
VON SCHEBEN DR. 1p jjQI
LOT 7 SLK 2 GREENBINK5U6 LOT SIZE 42032
GRac�%ah'+oK S �i�
TYPE OF SOIL ABSORPTION SYSTEM IS: TRENCH
MAXIMUM NUMBER OF BEDROOMS = 4 SOIL RATING CSO FT/BP.)= 1251,
THE REQUIRED SIZE OF THE SOIL ABSORPTION SYSTEM IS:
F>EF=,TH= 1ID L-ErJGTH= 42 (3FRR4-PEL OEF='TH= 1�-
THE LENGTH DIMENSION IS THE LENGTH CIN FEET) OF THE TRENCH OR DRAINFIELD.
THE DEPTH OF A TRENCH OR PIT I5 THE DISTANCE BETWEEN THE SURFACE OF THE
GROUND AND THE BOTTOM OF THE EXCAVATION CIN FEET).
THERE IS NO SET WIDTH FOR TRENCHES.
THE GRAVEL DEPTH IS THE MINIMUM DEPTH OF GRAVEL BETWEEN THE OUTFALL PIPE
AND THE BOTTOM OF THE EXCAVATION CIN FEET).
FRE:iDLj I FRED SEF='T I iC TFgrJF' S I LE= 1250 GnILLOfJS
PERMIT APPLICANT HAS THE RESPONSIBILITY TO INFORM THIS DEPARTMENT DURING THE
INSTALLATION INSPECTIONS OF ANY WELLS ADJACENT TO THIS PROPERTY AND THE
NUMBER OF RESIDENCES THAT THE WELL WILL SERVE.
--- TWO C ^ ? I rJSPEGT I C7tJS nFtE FREGIIJ I FZEI7 ---
BACKFILLING OF ANY SYSTEM WITHOUT FINAL INSPECTION AND APPROVAL BY THIS
DEPARTMENT WILL BE SUBJECT TO PROSECUTION.
MINIMUM DISTANCE BETWEEN A WELL AND ANY ON-SITE SEWAGE DISPOSAL SYSTEM IS
100 FEET FOR A PRIVATE WELL OR 150 TO 200 FEET FROM A PUBLIC WELL DEPENDING
UPON THE TYPE OF PUBLIC WELL.
MINIMUM DISTANCE FROM A PRIVATE WELL TO A PRIVATE SEWER. LINE IS 25 FEET AND
TO A COMMUNITY SEWER. LINE IS 75 FEET.
OTHER. REQUIREMENTS MAY APPLY. SPECIFICATIONS AND CONSTRUCTION DIAGRAMS ARE
AVAILABLE TO INSURE PROPER INSTALLATION.
F>EFRrl I T E1:F1 I FRES OECEMFE:EFZ = 1s
I CERTIFY THAT
1: I AM FAMILIAR WITH THE REQUIREMENTS FOR ON-SITE SEWERS
FORTH BY THE MUNICIPALITY OF ANCHORAGE.
2: I WILL INSTALL THE SYSTEM IN ACCORDANCE WITH THE CODES.
3: I UNDERSTAND THAT THE OM -SITE SEWER. SYSTEM MAY REQUIRE
RESIDENCE IS REMODELED TO INCLUDE MORE THAN 4 BEDROOMS.
., t
SIGNED:rS=`
GEORGE HAP.P.ISOFt
ISSUED BY
I
ALiR E51 -
AND
1
AND WELLS AS SET
ENLARGEMENT IF THE
1111LI CInL ihhh L151111,D164.
V4. 0
0 Alaska Testlab
4040 "g" Street Anchorage, Alaska 99507
Second and Fourth Anchorage
Limited Partnership
4611 Business Park Blvd.
Anchorage, Alaska 99503
Attention: Mr. Les Pace
Re: Subsurface Investigation
Disposal, Lot 7, Block 2,
Greenbrook Subdivision
Dear Mr. Pace:
n
Phone (907) 278-1551 ( Telecopier (707) 772.57
March 30, 1981
•W.O. #A19708
for Suitability of On -Site Sewage
Lot 11, Block 4, Lot 2, Block 5,
On March 14, 1981, we drilled -a 15 foot boring on each of the
.above three lots and placed a perforated, 3/4 inch PVC pipe in
each hole so that the water table could be monitored over a
period of time and a percolation test run in the hole. The holes
were drilled using a Nodwell mounted, Mobile B50 drill rig owned
-and operated by Denali Drilling, Inc. The drilling was supervised
and the test holes logged by Mr. Ted Krupka, senior technician
with Alaska Testlab.
After the holes were drilled, our technician returned on March 18
and checked the water level in each of the test holes. Fie then
returned again on March 23 and checked the water level again,
then saturated the holes, let them stand for 24 hours and returned
on March 24 to check the water level a third time and then ran a
percolation test. The percolation test was run by monitoring the
drop in the water table elevation at 10 minute intervals for a
minimum of one hour. The percolation rate listed in this report
was computed using the slowest 20 minutes of that percolation
test.
Included with this report is a test hole location sketch for each
lot and a log of the !boring placed on each lot.
The results of this exploration are described as follows:
n
Second and Fourth Anchorage
Limited Partnership
March 30, 1981
Page Two
Lot 7, Block 2
The test hole was placed in the front of the lot, and this is
where we would recommend the placement of the on-site sewage
disposal system. The lot slopes to the back considerably and it
appears there could be a water table problem at the very back end
of the lot. At the time of drilling no observed ground water
table was located. The soil appeared to be moist as the spring
thaw was beginning, and there was some seepage near the top of
the hole from thawing seasonal frost. When the water table was
checked on March 18, there was water standing in the hole at 8.55
feet. When the water table was checked again on March 23, prior
to saturation for the running of the pert test, the water table
had dropped to.10.5 feet. The next day when the percolation test
was run the hole was dry and there was no water table encountered
in the upper 15 feet of the hole. Percolation rate measured was
2.0 minutes per inch. It is our opinion that the relatively high
ground water encountered on March 18 was due to thawing seasonal
frost and runoff associated with breakup. The water table dropped
very quickly. however, it would be prudent to keep the system as
high as possible, in the upper 8 to 10 feet, to avoid problems in
the spring from breakup on the system. We would also recommend
using a more conservative design percolation rate of 5.0 minutes
per inch because the upper soils are slightly siltier than the
lower soils.
Lot 11, Block 4
Again, it would be important to keep the on-site sewage disposal
system in the front of the lot near test hole as it appears that
there is more of a ground water problem to the back of the lot.
No ground water was encountered to 15 feet in the boring at the
time of the exploration on March 14, 1981. on returning on
March 18, the water table was measured at 10.5 feet. It was
again measured at 10.5 feet on march 23, and again on March 24.
The percolation rate measured was 15.0 minutes per inch. Again,
the system should be kept as high as possible, in the upper 8 to
10 feet, because of the water associated with the spring thaw,
but it does appear that we picked up the highest level that the
water rose to during this spring.
Lot 2, Block 5
At the time the test hole was
conditions were encountered a
level was checked on march 18,
drilled on March 14,
t 13 feet. When the
standing water was
1981, saturated
water table
in the pipe, at
:A 1 E , AIASKA 1ES(1.,16
Second and rourth Anchorage
Limited Partership
March 30, 1981
11.5 feet. When it was checked again on ;larch 23, the water
level was at 13.5 feet. On March 24, prior to the running of the
percolation test, the water level was at 11.5 feet. Measured
percolation rate was 2.0 minutes per inch. However, because of
the silty nature of the soil we would recommend a more conserva-
tive value of 5.0 minutes per inch be used. Also, again, the
system should be kept as high as possible to avoid any conflict
with any seasonal fluctuation of the ground water associated with
thaw.
Should you have any questions with regard to these tests, please
do not hesitate to contact us.
very sincerely,
ALASKA TESTLAD
kQ. rte. �\ 1
Melvin R. Nichols, P.E.
Manager
MRN/mg
Attachments
cc: Ralph Westover, Tryck, Nyman & Hayes
Nom• O ...��Z
i Mohan R. N;'h'I'
f'• No. 4113E
"1 I t. I :.IASKA frSTI 'X
^ i o
'••°s.
Vp
�, i e '' .+ •ti! 17].]2
.9 V.. ° 000
p 6.12 6-10 •?1°9.t� o _ _1•
• 166.09
V I
O
•� 0
0 \ ._ " - x•06 ._.'
I
329.60
\0 10
I I
\ \C.: I II , 183.00
N
�%VAO S N 0 O
09 2� 0 ? 00 r B w m - 2
a
I-•
10
O _I _
w I _
O O
oO - 183.00
1, N89'00'00'E o_,
1 296.23 s. I I ,
• I
O N -
O 0.
�t
IST, n >I NB9'57'ai"E S
• _ I „•'l.o �' 180.00 m
QI I iF 183.00
N A iO ~ I I 13
30
75-3 °
- . — . NIN Y. •� I .
•1 �'O w -:O0
I
o Nla NB"2]'12W :ARI =0 n E1 10 I
N' 302.68 W:1
4.. S. •O n
163.00
�O O • �ri I
o
co 0
•� I
N84 -10'06-w
n ,
200.63
+ '-------- ?'2O'04 -w co 1
N '
290 43 No
O I O , L• .
m= n 0 O I 1
pi• W O '
MM 2 O1 5 ' 103.00
o � n
5 p
N7 > NI
646'09- 78•w y 24y1'µ' 0
= "- ?9".89 " 746.94 103.00
A i
i w 30 � 30 1
w 1
. V. 0
C; o
f tt
103.00
6.68• /. , �` 1 _ •
29'67 �•W ._..
`• � w � \ `-"�'+4.06 _ I i q ,'•
Lot 7, Block 2
Depth in Feet
From To
0.0 7.0
7.0 15.0
n ^
Table B V7O #A19708
Date: 3/14/81
Logged by: T. Krupka
Bottom of Test Hole:
Frost Line:
Free Water Level:
Soil Description
F -2/F-4, brown Silty Sand, SM, silt to 408,
moist
F -2/F-4, brown Si try Gravelly Sand, SDt,
particles to 1", silt to 308, saturated by 10'
Set 3/4" perforated PVC pipe to run perc test
and to monitor water table elevation.
Measured perc rhte = 2.0 minutes/inch.
Recommended design rate = 5.0 minutes/inch.
15.0 Feet
1.0 Foot
3/14/81 - 10.0 Feet
3/18/81 - 8.5 Feet
3/23/81 - 10.5 Feet
3/24/81 -.No Water Observed
0
n n
'c n1e.]a e1+0
[
1318.15 T,N.6N.
W 1320.00 G.L.O. .—.__ . _ - ,— •-- .220.00-- - f—
Rood i
26].6] SO ]0
10•U111. [sm 1. ..__ i
O « p O
O O
N.
u
t
oN
' _ I QST RO • p0 > O
T1 vL� ee0 O�:D'1'
-....
O
•O 00 �•>>
1 ] 0 � BJ
9.40
p 165 C`1 00 °O�
Ser•4 / 00 0.,
40-,
1]9.40 40•I]'00/' 1T q•$
Tag T.II-fit 149 \Z 28]j
Drive
1 J 9..q p
P.R. > O J 0' ; �3
p N
O
p Q JO iI
• 8 r \ � V O //
' Q O O
` I
A 9 Fiat., 1'27"i
ee0 /O N 9 C OO 268.32
•O" p ,0
46J.0' °0
00
B 4
P�
.4,
:' M1
o .
M1
Fi
.7
Ur!!
Z
,t -r sT
�jL'G w
V 1•
9
J
G1
/2
A- -O.•Ur.
4�gaa flmr
i ��!•9,J�000`,
t
•� L b
,q
>b
Ot
SI-
.
I -
.w
1
r
I
r
47.t]
O N89•56'10 -W 211.00
18].00
1
i r•
1
' O
105-00
2
IU 3.00
� n .
^Lot 11, Block 4 Table A. Y70 #A19708
Date: 3/14/81
.Logged by: T. Krupka
Depth in Feet
From To Soil Description
0.0 0.5 Organic cover
0.5 15.0 F -2/F-4, brown Silty Sand, sm, with some
gravel (108) to 3 4", silt to 308, firm,
moist
Bottom of Test bole:
Frost Line:
Free Water Level:
Set 3/4" perforated PVC pipe to run perc
test and to monitor water table elevation.
Perc rate = 15.0 minutes/inch.
15.0 Feet
1.0 Foot
3/14/81 - Non Observed
3/18/81 - 10.5 Feet
3/23/81 - 10.5 Feet
3/24/81 - 10.5 Feet
n �
Lot 2, Block 5 Table C WO #A19708
Date: 3/14/81
Logged by: T. Krupka
Depth in Feet
From To Soil Description
0.0 15.0 F -2/F-4, brown Silty Gravelly Sand, SM, gravel
to 3/4", silt content to 40%, saturated by 13.0'
Set 3/4" perforated PVC pipe to run perc test
and to monitor water table elevation.
Measured per rate = 2.0 minutes/inch.
Recommended design rate = 5.0 minutes/inch.
Bottom of Test Hole:
Frost Line:
Free Water Level:
15.0 Feet
1.0 Foot
3/14/81 -
13.0
Feet
3/18/81 -
11.5
Feet
3/23/81 -
13.5
Feet
3/24/81 -
11.5
Feet
k �uo71
IG'
zv
i' /LSv
o' 3 0
c5 "?p Y-� e `I ►t t �-v u c J..ea�
r
© (S-c—
(� w a -t max- a
LUW-IL�3" ;;L `u�.
4A-X-c't v -d - r_-I.f C GQ�P C/� P-oy G2�
MUNICIPALITY OF ANCHORAGE
Development Services Department NtDA__� Phone: 907-343-7904
On -Site Water & Wastewater SectionFax: 907-343-7997
Certificate of On -Site Systems Approval
Parcel I.D. 017-023-59-000
Legal description GREENBROOK BLK 2 LT 7
Expiration Date: 9/10/2025
Site address 12840 VON SCHEBEN DR Anchorage AK 99516
Current property owner(s) DELESLINE AMY & JOHN DAVID
X The On-site system(s) is/are approved for 4 bedrooms
Conditional approval for bedrooms, with the following stipulations:
Comments or advisories:
a
Original Certificate Date: 11/14/2024
Certificate of On -Site Systems Approval (COSA) is intended to demonstrate the subject
system(s) is/are in substantial compliance with municipal code. The Municipality of
Anchorage, Development Services Department (DSD) issues COSAs based upon
representations provided by an independent professional engineer. The Municipality of
Anchorage is not responsible for errors or omissions in the professional engineer's work.
I� i�T�7: I ►�iL�1► � �+�
COSA Checklist X Well Flow Advisory
Absorption Field Advisory Nitrate Advisory
Tank Age Advisory X Arsenic Advisory
Other
COSA ApprovaIjune 2022
MUNICIPALITY OF ANCHORAGE
Development Services Department
On -Site Water & Wastewater Section
Phone: 907-343-7904
Fax: 907-343-7997
Certificate of On -Site Systems Approval Application
1. GENERAL INFORMATION
Parcel I.D. 017-023-59
Complete legal description GREENBROOK BLOCK 2, LOT 7
Location (site address) 12840 VON SCHEBEN DRIVE, ANCHORAGE, AK 99561
Current property owner(s) AMY & JOHN DELESLINE Day phone
2. ON-SITE SYSTEMS SIZED FOR 4 BEDROOMS
3. TYPE OF WATER SUPPLY: ❑ Private Well ❑ Private Well serving 2 dwelling units
❑ Private Well serving 3+ dwelling units ® Community Well or Public
❑ Water Storage
4. TYPE OF WASTEWATER DISPOSAL: ® Private Septic ❑ Private Septic serving 2 dwelling units
❑ Holding Tank ❑ Community Septic or Public Sewer
5. SEPTIC TANK: ® Steel ❑ Plastic ❑ Concrete ❑ Fiberglass
Age 21 - See advisory if steel older than 20 years
6. ABSORPTION FIELD: ❑ AWWTS ❑ Bed ❑ Deep Trench ® Wide Trench ❑ Seepage Pit
Waiver request for:
Expedited review requested:
Distance:
By applying for this entitlement, this property is subject to inspection by municipal On-site staff
to verify the accuracy of the information provided.
COSA Fee $ Waiver Fee $
Date of Payment '0'01 y Date of Payment
COSA # sC 2. y % l 4- � Waiver #
COSA Application.doc
COSA Checklist.docx
COSA Checklist
Legal Description: GREENBROOK BLOCK 2, LOT 7 Parcel ID: 017-023-59
If more than 1 well and/or septic system on lot, provide separate checklist. Structure served by this system ____
A. WELL DATA - PUBLIC &/OR CLASS “A” WATER
Well log is filed with Onsite (or attached)
Date drilled Total depth ft
Cased to ft
Sanitary seal is functioning correctly
Wires are properly protected
Casing height (above ground) in.
Date of flow test for COSA
Static water level at beginning of test ft.
Well production at time of test gpm
Water storage tank volume NONE gallons
Well disinfected for coliform test? Yes No
Coliform bacteria is Negative
Nitrate mg/L Nitrate less than MRL (ND)
Arsenic ug/L Arsenic less than MRL (ND)
Collected by
Date
Comments __________________________________________________________________________________
B. TANK DATA
Measured operating fluid level in septic tank 49”
Date of pumping 9/10/24
Required maintenance completed, if AWWTS
Comments:
C. LIFT STATION
Required maintenance completed
Age of lift station years
Lift station material
Comments:
D. ABSORPTION FIELD DATA
Which system tested (date installed) NEW FIELD
ALL standpipes present per record drawing
Total measured depth from grade 6.6 ft (max)
Measured depth to pipe invert from grade 3.24 ft (min)
N/A – pressurized field.
Per record drawings, field is insulated.
Monitor tubes (MT) go to bottom of effective (ED).
If not, state depth into effective
Presoaked required if
(Required if house vacant or field not used for more
than 30 days prior to date of test)
Gallons introduced gallons date
Any rejuvenation treatment (past 12 months) N
If yes, enter date
Adequacy test date *NA – NEW FIELD
Results Pass
Fluid depth prior to test in
Water added gal
New fluid depth in
Elapsed time min
Final fluid depth in
Absorption rate gpd
FIELD STATUS – POST RECOVERY *NOT TESTED
Effective depth (per record drawings) 36 in (MOA 3’ ED)
Effective depth used 0 in
Effective depth remaining 36 in
Comments/Deficiencies: Approximate total measured depths from existing grade.
COSA Checklist.docx
E. SEPARATION DISTANCES
From Private Well on Lot to: (Please enter distances if less than required or if community well on lot) - NA
Septic Tank/Lift Station on Lot > 100’
Yes if No ft
Neighboring Tank > 100’ Yes if No ft
Absorption Field on Lot > 100’ Yes if No ft
Neighboring Absorption Fields > 100’
Yes if No ft
Community Sewer Main > 75’ Yes if No ft
Community Sewer Manhole/Cleanout > 100’
Yes if No ft
Private Sewer/Septic Line > 25’ Yes if No ft
Holding Tank > 100’ Yes if No ft
Animal Containment > 50’ Yes if No ft
Manure/Animal Excreta Storage > 100’
Yes if No ft
N/A – Served by Community Well (not on lot) or Public Water
From Septic/Holding Tank and Absorption Field(s) on Lot to: (Please enter distances if less than required)
Building Foundations > 10’ Yes if No ft
Tank to Property Line > 5’ Yes if No ft
Field to Property Line > 10’ Yes if No ft
Water Main > 10’ Yes if No ft
Water Service Line > 10’ Yes if No ft
Surface Water > 100’ Yes if No ft
Wells on Adjacent Lots:
Private Wells > 100’ Yes if No ft
Community Wells > 200’ Yes if No ft
If tank or field is under driveway comment below
F. ENGINEER’S COMMENTS
G. CERTIFICATION & STATEMENT OF INSPECTION BY ENGINEER
As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based
on procedures outlined in the Certificate of On-Site Systems Approval Guidelines, indicates that the on-site water
supply and/or wastewater disposal system appears to comply with applicable Municipal and State codes,
ordinances, and regulations in effect at the time of installation, unless noted otherwise.
Name of Firm FIRST WATER CONSULTING Phone 907-350-9566
Engineer’s Printed Name CURTIS HUFFMAN, PE Date 11/13/2024
Comments: This investigation was completed in compliance with MOA guidelines, regulations,
and best industry practices / methods. The assessment of the condition of the well and septic
applies only to the conditions as of the day tested. The flow and absorption rates may change
due to subsurface conditions that may not be observed from the surface, changes in land use,
local soil characteristics, groundwater levels that may fluctuate during the year, quality of
construction (workmanship & materials), the water usage of the family being served by the
system and maintenance. The operational life of all well and septic systems are subject to
these various and dynamic characteristics and are outside the control of the evaluator of the
well and septic system. Therefore, any or NO estimate of how long a system will function satisfactory
for current or future occupants or guarantee that no unseen encroachments, deficiencies or
discrepancies exist can be given by First Water Consulting &
11/13/24
MUNICIPALITY OF ANCHORAGE
DEVELOPMENT SERVICES DEPARTMENT o
On -Site Water and Wastewater Section
www.muni.org/onsite
Septic Tank Advisory
Certificate of On -Site Systems Approval # OSC241465
Subdivision: Greenbrook Block:2, Lot: 7
907-343-7904
Fax: 343-7997
The septic tank for this property is 21 years old. The average life of an asphalt
coated steel septic tank is 20 years. Typical replacement costs are $15,000 or more,
not including engineering, surveying, MOA permitting fees or site restoration.
This advisory must be attached to all copies of the subject Certificate of On -Site
Systems Approval.
This is an example of what the metal of a 30 year old steel tank MAY look like.
C
cl
Lr
C
0
N
Di
c Ra°nn'nn"\AI 295.25'
Of
S 4
49 TH
SHANE A. HOLT.. m i
�40 LS -6914 yo`o0�
44���°Jes sione� �'ocao
N
ti
N
W
rn
N
J
M
r
r
J
LNlWwj'�"�V'jr
AS -BUILT SURVEY 1" = 40`
NO CORNERS SET THIS DATE
OF THE FOLLOWING DESCRIBED PROPERTY
LOT73L00(2 G1?,FA131?00KSUB
INFORMATIONHEREONISFOR THE USE OFLENDINGINSTITUTIONSSPECIFIC LLYTOSHOWANY ANCHORAGE RECORDING DISTRICT, ALASKA, AND THAT THE
FLICTS BETWEEN EXISTING STRUCTURES AND PLA TTED LOTLINESANO/OREASEMENTS. VISIBLE IMPROVEMENTS SITUATED THEREON ARE WITHIN
EMENTS OFRECORD, OTHER THAN THOSEAPPEARING ON THERECORD PLAT, ARENOTSHOWN THE PROPERTY LINES AND NO VISIBLE ENCROACHMENTS
EON(UNLESSINDICATED) EXIST OTHER THAN NOTED.
E. FENCELINESTHATMAYAPPEARONTHISDRAWINGARENOTTOBEUSEDTODETERMNE DATED AT ER THAN NOTED.
THIS I I TH DAV OF
PERTYLINES ORPOSITIONADOMONAL IMPROVEMENTS.
PAVING SHOWN HEREON MA Y BEAPPROXIMA TE DUE TO EXCESSIVESNOWAND/OR ICE. IV�VENlBET� , 2024
HOLT LAND SURVEYING
9309 GROVER DRIVE
9/53 108-25,109-36 239-52 90]23 AK 9950]
8615
e�
Municipality of Anchorage
• Development Services Department
Building Safety Division `
OnSito Water & Wastewater Program i
4700 South Bragaw SL
P.O. Box 196650 Anchorage, AK 99519-6650
www.ci.anchorage.ak.us
(907)343-7904
CERTIFICATE OF HEALTH AUTHORITY APPROVAL
FOR A SINGLE FAMILY DWELLING
Parcel I.D. 017-023-59 HAA# 1250501
1. GENERAL INFORMATION Expiration Date: 9 — a 1
Complete legal description LOT 7. BLOCK 2. GREENBROOK SUBDIVISION
Location (site address or directions) 12840 VON SCHEBEN DRIVE ' ANCHORAGE. AK 99516
Current Property owner(s)
Mailing address
Lending agency
Mailing address
Real Estate Agent
Mailing address
MATTHEW do KRISTINA DAGGM Day phone
C/O AGENT
Day phone
KATHLEEN POULIN w/ PRUDENTIAL JW Day phone 762-7560
3801 CENTERPOINT OR. STE. 200 • ANCHORAGE. AK 99503
Unless otherwise requested, HAA will be held by DSD for pickup.
2. NUMBER OF BEDROOMS: 4
3. TYPE OF WATER SUPPLY:
Individual Well ❑
Individual Water Storage ❑
Community Class *A*
Public Water System ❑
TYPE OF WASTEWATER DISPOSAL:
Individual On-site
Individual Holding tank
❑
Community On-site
❑
Public Sewer
❑
The Municipality of Anchorage Development Services Department (DSD) Issues Certificates of Health Authority
Approval (HAA) based only upon the representations given in paragraph 4 by an Independent professional civil
engineer registered in the State of Alaska. Certificates of Health Authority Approval are required for the transfer
of title (except between spouses) for properties served by a single-family on-site wastewater disposal and/or
water supply system. DSD also issues HAAs upon request to homeowners. Certificates of Health Authority
Approval are valid for 90 days from the date of issue for properties served by a private or Class C well and may
be reissued with new water samples. (Certificates may be reissued for a period of up to one year with valid water
samples.) Certificates are valid for one year for properties served by Class A or B wells or a public water system.
The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work.
4. STATEMENT OF INSPECTION BY ENGINEER
As cerGlied by my seal affixed hereto and as of the validation date shown below, I verify that my
investigation, based on procedures outlined In the Health Authority Approval Guidelines for this application,
shows that the on-site water supply and/or wastewater disposal system is(are) safe, functional and adequate
for the number of bedrooms and type of structure Indicated herein. I further verify that based on the
information obtained from the Municipality of Anchorage riles and from my investigation and inspection, the
on-site water supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal
and State codes, ordinances, and regulations in effect at the time of installation.
Name of Firm GARNESS ENGINEERING GROUP, Ltd.
Address 3701 E. TUDOR ROAD, SUITE 101 * ANCHORAGE, AK 99507
Engineer's Printed Name JEFFREY A. GARNESS, P.E.
Engineer's Comments:
In conducting this evaluation, GEG, Ltd. attempted to provide a thorough,
conscientious engineering analysis of the system in accordance with ADEC and MOA
DSD Guidelines 8 Regulations. The reported results described the performance of the
system under the conditions encountered at the time of the test, and separation
distances measured to readily idontifiable features. The operational life of all wells and
septic systems depend on the local soils condition, groundwater levels that may
fluctuate during the year, and the water usage of the family being served by the system.
These conditions are outside the control of the evaluator of the system. Satisfactory test
results do not guarantee future performance of the system, nor do they guarantee that
there are no hidden defects or encroachments. GEG, Ltd. can therefore not provide
any warranty or future estimate of how long the system will continue to meet the
operational requirements of the ADEC or MOA DSD. The content of this report Is for
the sole benefit of the owner listed above. Any reliance upon or use of this report by any
other person or party is not authorized, nor will It confer any legal right whatsoever.
5. DSD SIGNATURE
Approved for bedrooms.
Disapproved.
Conditional approval for
Phone 337-6179
Date 9 42LI/09
bedrooms, with the following stipulations:
UR5T1 E -
�TERAND
' .
WASTEWATER
• •
Attachments: /
HAA Checklist l/
Septic System Advisory
Well Flow Advisory
Maintenance Agreements
Supplemental Engineer's Report
Other
By: ' 1 Original Certificate Date:
(Rw. 17/01)
Municipality of Anchorage
• Development Services Department
Building Safety Division
OnS4e Water & Wastewater Program
4700 South Bragaw SL
P.O. Box 196850 Anchorage, AK 99519-WSO
www.cl.anchorage.ek.us
(907)343-7904
HEALTH AUTHORITY APPROVAL CHECKLIST
Legal Description: GREENBROOK SUBDIVISION; LOT 7. BLOCK 2. Parcel ID: 017-023-59
A. WELL DATA
Well type -A" If A, B, or C provide PWSID# 210346 Well Log (Y/N)
Date completed Sanitary seat (Y/N)_ Wines props ed (INN)
Total depth ft. Cased to ft. WE1a
FROM WELL LOG GOMMUNtCf
Date of test
Static water level
WATER SAMPLE RESULTS:
Coliform oolonies/100 ml. Nitrate
Date of sample:
B. SEPTICIHOLDING TANK DATA
Tank Type/Material STEEL
(above ground) in.
AT INSPECTION
ft.
g.p.m.
Collected by:
00 ml.
Date installed 12/2-3/2003
Tank size 1250 gal. Number of Compartments E Cleanouts (Y/N) YES
Foundation cleanout (Y/N) YES Depression over tank (YM) NO High water alar (Y/N) N/A
Date of pumping 11/3/2005 Pumper NORTHLAND PUMPING
C. ABSORPTION FIELD DATA *BELOW EXISTING GRADE
Date installed 12/2-3/2003 Soil rating OEr ftibdr) 0_6 System type TRENCH
Length 59 ft. Width 2.5 ft. Gravel below pipe 8.5 ft.
Total depth 'I > •3 ft. Eff. absorption area 1003 ft' Monitoring tube YES Depression over field NO
Date of adequacy test 42 YEARS OLD Results (Pass/Fail) PASS For 4 bedrooms
Fluid depth in absorption field before test 26 in. Water added =gal. New depth =in.
Elapsed Time: = min. Final fluid depth _ in. Absorption rate >= — g.p.d.
Any rejuvenation treatment (past 12 mo.) (Y/N &type) — If yes, give date —
SEPTIC SYSTEM IS LESS THAN 2 YEARS OLD.
THE DRAINFIELD HAD 0-26 INCHES OF H2O ON 9/23/2005.
D. LIFT STATION
Date installed _
"Pump on" level at _in.
E. SEPARATION DISTANCES
Size in gallons
Pump�vaFet�ln. High water alarm level at in.
Cycles tested Meets alarm & circuit requirements?
SEPARATION DISTANCES FROM WELL ON LOT TO: COMMUNITY WELL
Septic tank/lift station on lot
On adjacent lots
Absorption field on lot
On adjacent lots
Public sewer main
Public sewer manholeldeanout
c service line
Holding tank
SEPARATION DISTANCES FROM SEPTICIHOLDING TANK ON LOT TO:
Building foundation 5'+
Property line 5'+ Absorption field 5'+
Water main 10'+
Water service line 10'+ Surface water t 00'+
Wells on adjacent lots 200'+
SEPARATION DISTANCE FROM ABSORPTION FIELD ON LOT TO:
Property line t0'+
Building foundation 10'+ Water main 10'+
Water service line 10'+
Surface water 100'+ Driveway, parkingtvehide storage 10'+
Curtain drain NONE KNOWN Wells on adjacent lots 200'+
F. COMMENTS
G. ENGINEER'S CERTIFICATION
I certify that 1 have determined through field inspecWns and * {4 f r#
review of Municipal records that the above systems are in
i
conformance with MOA HAA guidelines in effect on this date.
.......
'•,Jef G esa.:
Engineer's Printed Name JEFFREY A GARNESS E—
Date 'k 7/os-
OO 7G y trSEo4
��pr6l��tio�d
HAA Fee E 4_-V
Date of Payment 9 -27 -rte
Receipt Number 7y52-7 IBM
(Rev. 12101)
Waiver Fee $ _
Date of Payment
Receipt Number,
'■IE
||||
)
||�
�§!
■
!|
|§�)
w�
/
A /
■
R oX
3n a--------------------
A3e3HOS
love-�
�/
Vp 27 05 10:18a Kathleen Poulin
086'a4P-26-20015 06:57p FROM:
.o
Sao
.414NLAND PUMPING SERVICE, INC.
;b`ur Professional Septic Pumping Service Company
7,501 E. 14091 Avenue
ANCHORAGE. ALASKA 99516
(907) 344-7146 FAX (907) 868-6770
ro - (�istianDaggett
12840 Von Scheben Drive
Anchorage, AK 94516
,�.
907-762-7563 p.1
70:7627563 r:eIc
[NVOIGE1
15883
100.00
Thank you for choosmgNorthlaad.PumpingSelli c,ili-Attactied.is.alist of
P WeaLiamaiLiii�eminder card
Do's;and Dod'ts that we hope you find helpfi+L••
is a years tyme .for year cmvenience. Please don't hesitate;tn call if you have
aay.queitacos. 11anlc•, BEV
_sf
6.17-1059
17103 125 gallons (new system) S 00 ge
THANK YOU
Municipality_of Anchorage
• "` Development Services Department °
/ Building Safety Division .. .,.
On -Site Water 8 Wastewater Program
4700 South Bragaw St.
P.O. Box 196650 Anchorage, AK 99519-6650
www.ci.anchorage.ak.us
(907) 343-7904
CERTIFICATE OF HEALTH AUTHORITY APPROVAL
FOR A SINGLE FAMILY DWELLING
1 f
Parcel I.D. 017-023-59 HAA# (N Or-) 14
1. GENERAL INFORMATION Expiration Date:1 fl ks-
Complete legal description LOT 7
BLOCK 2.
GREENBROOK
SUBDIVISION
Community On-site
❑
Public Sewer
Location (site address or directions)
12840
VON SCHEBEN
DRIVE • ANCHORAGE. AK 99516
Current Property owner(s)
Mailing address
Lending agency
Mailing address
Real Estate Agent
Mailing address
JOHN MCCONNAUGHY Day phone 333-1235
12840 VON SCHEBEN DRIVE • ANCHORAGE. AK 99516
Unless otherwise requested, HAA will be held by DSD for pickup.
2. NUMBER OF BEDROOMS: 4
3. TYPE OF WATER SUPPLY:
Individual Well ❑
Individual Water Storage ❑
Community ClasswAw_Well
Public Water System ❑
Day phone
Day phone
TYPE OF WASTEWATER DISPOSAL:
Individual On-site
0
Individual Holding tank
❑
Community On-site
❑
Public Sewer
❑
The Municipality of Anchorage Development Services Department (DSD) Issues Certificates of Health Authority
Approval (HAA) based only upon the representations given in paragraph 4 by an independent professional civil
engineer registered in the State of Alaska. Certificates of Health Authority Approval are required for the transfer
of title (except between spouses) for properties served by a single-family on-site wastewater disposal and/or
water supply system. DSD also Issues HAAs upon request to homeowners. Certificates of Health Authority
Approval are valid for 90 days from the date of issue for properties served by a private or Class C well and may
be reissued with new water samples. (Certificates may be reissued for a period of up to one year with valid
water samples.) Certificates are valid for one year for properties served by Class A or B wells or a public water
system. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's
work.
4. STATEMENT OF INSPECTION BY ENGINEER
As certified by my seal affixed hereto and as of the validation date shown below, I verify that my
Investigation, based on procedures outlined in the Health Authority Approval Guidelines for this application,
shows that the on-site water supply and/or wastewater disposal system is(are) safe, functional and adequate
for the number of bedrooms and type of structure indicated herein. I further verify that based on the
information obtained from the Municipality of Anchorage riles and from my investigation and inspection, the
on-site water supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal
and State codes, ordinances, and regulations in effect at the time of installation.
Name of Firm ALASKA WATER & WASTEWATER CONSULTANTS, INC.
Address 3701 E. TUDOR ROAD, SUITE 101 • ANCHORAGE, AK 99507
Engineer's Printed Name JEFFREY A. GARNESS, P.E.
Engineer's Comments:
In conducting this evaluation, AKWWC, Inc. attempted to provide a thorough,
conscientious engineering analysis of the system in accordance with ADEC and MOA
DSD Guidelines 8 Regulations. The reported results described the performance of the
system under the conditions encountered at the Lime of the test, and separation
distances measured to readily identifiable features. The operational life of all wells and
septic systems depend on the local soils condition, groundwater levels that may
fluctuate during the year, and the water usage of the family being served by the system.
These conditions are outside the control of the evaluator of the system. Satisfactory test
results do not guarantee future performance of the system, nor do they guarantee that
there are no hidden defects or encroachments. AKWWC, Inc. can therefore not provide
any warranty or future estimate of how long the system will continue to meet the
operational requirements of the ADEC or MOA DSD. The content of this report is for
the sole benefit of the owner listed above. Any reliance upon or use of this report by any
other person or party is not authorized, nor will it confer any legal right whatsoever.
5. DSD SIGNATURE
Approved for bedrooms.
Disapproved.
Conditional approval for bedrooms, with the filowing
Attachments:
HAA Checklist
Septic System Advisory
Well Flow Advisory
Phone —337-6179
Date I2 it Z 03
`�V ,�yo
' . ON-SITE
WATER AND : m
Manitenance Agreements
Supplemental Engineer's Reort
Other
riv , ,Ins Lr\
PROGRAM
M
By: Original Certificate Date: r ILL
(Rev. 1201)
Municipality of Anchorage
Development Services Department
Building Safety Division a „
On -Site Water & Wastewater Program
4700 South Bragaw St.
P.O. Box 196650 Anchorage, AK 99519.6650
www. rd.anctwmge.ak.us
(907)343-79W
HEALTH AUTHORITY APPROVAL CHECKLIST
Legal Description: GREENBROOK SUBDIVISION: LOT 7, BLOCK 2. Parcel ID: 017-023-59
A. WELL DATA
Well type *A" If A. B, or C provide PWSID# 210,346 Well Log (YIN)
Date completed Sanitary seal (Y/N)_ Wires props ed (Y/N)
Total depth ft. Cased to ft. � �l g height (above ground) in.
FROM WELL LOG �MMUN AT INSPECTION
Date of test
Static water level
W�uction 9.p -m.
WATER SAMPLE RESULTS:
ft.
g.p.m.
Coliform colonies/100 ml. Nitrate mg./L. Other bacteria colonies/100 ml.
Arsenic: mg./L. Date of sample: Collected by:
e. SEPTICIHOLDING TANK DATA
Tank Type/Material STEEL Date installed 12/2-3/2003
Tank size 1250 gal. Number of Compartments 2 Cleanouts (Y/N) YES
Foundation cleanout (Y/N) YES Depression over tank (Y/N) NO High water alarm (YIN) N/A
Date of pumping NEW Pumper
C. ABSORPTION FIELD DATA
Date installed 12/2-3/2003 Soil rating .p.d. ft'lbdrm) 0_6 System type TRENCH
Length 59 ft. Width 2.5 ft. Gravel below pipe 8.5 ft.
Total depth 012.5 ft. Eff. absorption area 1003 ft' Monitoring tube YES Depression over field NO
Date of adequacy test NEW Results (Pass/Fail) — For 4 bedrooms
Fluid depth in absorption field before test = in. Water added =gal. New depth =in.
Elapsed Time: = min. Final fluid depth = in. Absorption rate >= — g.p.d.
Any rejuvenation treatment (past 12 mo.) (YIN & type) — If yes, give date —
D. LIFT STATION
Date installed
"Pump on" level at _in.
E. SEPARATION DISTANCES
Size in gallons
High water alarm level at
Cycles tested Meets alarm & circuit requirements?
SEPARATION DISTANCES FROM WELL ON LOT TO:
Septic tank/lift station on lot
Absorption held on lot
Public sewer main
line
COMMUNITY WELL
On adjacent lots
On
Public sewer manhole/cleanout
Holding tank
SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK ON LOT TO:
Building foundation 5'+ Property line 5'+ Absorption field 5'+
Water main 10'+ Water service line 10'+ Surface water 100'+
Wells on adjacent lots 200'+
SEPARATION DISTANCE FROM ABSORPTION FIELD ON LOT TO:
Property line 10'+ Building foundation 10'+ Water main 10'+
Water service line 10'+ Surface water 100'+ Driveway, parking/vehicle storage 10'+
Curtain drain NONE KNOWN Wells on adjacent lots 200'+
F. COMMENTS
G. ENGINEER'S CERTIFICATION
1 certify that I have determined through field inspections and : �•' '\ >r
review of Municipal records that the above systems are in
conformance with MOA HAA guidelines m effect on this date.
$... .... .9....... .
rn
7
s.
Engineer's Print d N e JEFFREY A. GARNESS � ••
Date t L�12.T0;
HAA Fee $ 4�0 Waiver Fee $
Date of Payment Date of Payment
Receipt Number. j-� T Receipt Number
(Rw. rzo1)
.n
eo�',
1 MUNICIPALITY OF ANCHORAGE
DEPARTMENT OF HEALTH AND ENVIRONMENTAL PROTECTION
DIVISION OF ENVIRONMENTAL HEALTH
CERTIFICATE OF INSPECTION FOR HEALTH AUTHORITY APPROVAL
OF ON-SITE SEWER AND WATER FACILITY
264-4720
Application Dale "
1. GENERAL INFORMATION
(a) Legal Description (include lot, block, subdivision, section, township, range) /q�
I ^-r— -7 'r2 t/ n Cdrer=LITkJn.,v SEL K6
Location (address or directions)
�� �D lL}kL��tl' ifs E►.I
(b) Applicant Name _E� ccso_�Je _ elephone: Home Business
Applicant Address
(c) Applicant is (check one): Lending Institution O ; Owner/builder ❑ ; Buyer O ; Other O (explain);
(d) Lending Institution 40A4_ t= n,7 r 7-y Telephone
Address
(e) Real Estate Company and Agent
Address • T2
Telephone Xb 3 - 'i o 0-0
(1) Mail the HAA to the following address:
2. TYPE OF RESIDENCE
Single-FamilyA Multi -Family OO Other
Number of Bedrooms 7
i
3. WATER SUPPLY
Individual Well Community ❑ Public ❑
Note: If com unity well system, must have written confirmation from the State Department of Environmental Conservation
attesting to the legality and status.
4. SEWAGE DISPOSAL
Onsite Public ❑ Community O Holding Tank ❑
Note: 6 communitywell system, must have written confirmation from the State Department of Environmental Conservation
attesting to the legality and status.
72.025 (11,64)
Page 1 of 2
n
tocol+
5. ENGINEERING FIRM PROVIDING INSPECTIONS, TESTS, FILE SEARCH, DATA AND INFORMATION
As certified by my seal affixed hereto and as of the validation date shown below, I verify that my Investigation of this Health
Authority Approval shows that the on-site water supply and/or wastewater disposal system is safe, functional and adequate
for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained
from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or
wastewater disposal system is in compliance with all Municipal and State codes, ordinances, and regulations in effect on
the date of this insppection.
Name of Firm � r^
Telephone
Address
Date
CIF /t(Zt
�P18••.... •'ril'�f
h. ••;' j
4 TO yt�
� '
__*: „ .........: I'D Seal
I ,. 2225-E
Y; 25. 1971 : •;',
6. DHEPAPPROVAL (�) / fJ6
Approved for G bedrooms by bate � a! (6
Approved Disappro ed Conditional
Terms of Conditional Approval
CAUTION
The Muncipality of Anchorage Department of Health and Environmental Protection (DHEP) Issues Health Authority
Approval certificates based solely upon the representations given in paragraph 5 above by an independent professional
engineer registered in the Stale of Alaska. The DHEP does this as a courtesy to purchasers of homes and their lending
Institutions In order to satisfy certain federal and state requirements. Employees of DHEP do not conduct inspections or
analyze data before a certificate is issued. The Municipality of Anchorage is not responsible for errors or omissions in the
professional engineer's work.
Page 2 of 2
72-025 (11,84)
MUNICIPALITY OF ANCHORAGE (MOA)
MtJNK:IPALrTY OF ANO10RAt';KHEALTH AUTHORITY APPROVAL (HAA)
DEPT. OF HEALTH 6 CHECKLIST - FEBRUARY 1984
INVIRONMENTAL PROTECnOI4 264-4720 .
MAY 191986 Legal Description: LOT —7f 5W 2-
_C2_�Es:
f� N Pe e9 t = e �� �" 12N4 ►ifs
A. WELLDATARECE+IVED
/
Well Classification y -1,&5 , A If A. B. C. D.E.C. Approved (Y/N)
Well Log Present (Y/N) Date Completed
Total Depth
Static Water Level
Cased to
Casing Height Above Ground _
Electrical Wiring in Conduit (Y/N)
Depth of Grouting —
Pump Set At
Yield
Sanitary Seal on Casing (Y/N)
Depression Around Wellhead (Y/N)
Separation Distances from Well:
To Septic/Holding Tank on Lot On Adjoining Lots
To Nearest Edge of Absorption Field on Lot _>�� ; On Adjoining Lots
To Nearest Public Sewer Line
Cleanout/Manhole _
Water Sample Collected by
Water Sample Test Results
Comments
B. SEPTIC/HOLDING TANK DATA
— To Nearest Public Sewer
To Nearest Sewer Service Line on Lot
; Date
Date Installed VZY& Size d No. of Compartments "f !Y/0
Standpipes (Y/N) 'EL100 Air -tight Caps (Y/N) y Foundation Cleanout (Y/N) _ _ y
Depression over Tank (Y/N) H Date Last Pumped r11 7/8(
Pumping/Maintenance Contract on File (Y/N) W^ ; for KLA
Holding Tank High -Water Alarm (Y/N) WA Temporary Holding Tank Permit (Y/N) WA
Separation Distances from Septic/Holding Tank
To Water -Supply Well > 140"o To Building Foundation
To Property Line i 10 To Disposal Fieldy
To Water Main/Service Line To Stream, Pond, Lake, or Major Drainage
Course Ney�
Comments
Page 1 of 2
72-026(11184)
C. ABSORPTION FIELD DATA
Soils Rating in Absorption Strata I fi5 Type of System Design Tftiff WeH
Date Installed 0/141ti Length of Field H.Z.
Width of Field 3o t Depth of Field Cl
Gravel Bed Thickness
Square Feet of Absorption Area 5 C 4 Standpipes Present (Y/N) T S* O
Depression over Field (Y/N) N Date of Last Adequacy Test 511g,
Results of Last Adequacy Test �nqg �... y �o�vo.►w3
Separation Distance from Absorption Field:
To Water -Supply Well > J4.0 To Property Line i 20
To Building Foundation Iss To Existing or Abandoned System on
Lot NONg ; On Adjoining Lots 1 50
To Water Main/Service Line > 1P To Cutbank (if present) N ON Ic
To Stream/Pond/Lake/or Major Drainage Course N w4 L
To Driveway, Parking Area, or Vehicle Storage Area V tAJ4%r t e�w4
Comments
D. LIFT STATION
Date Installed
Size in Gallons
"Pump On" Level at —
High Water Alarm Level at
Tested for
Electrical Codes (Y/N) _
Comments
Dimensions
Manhole/Access (Y/N)
— "Pump Off' Level at
Check Permitted Bedroom Rating Against HAA Request ••
Vent(Y/N)
Pumping Cycles during Adequacy Test. Meets MOA
Icertify that Ihave checked, verified , r conformed to all MOA and HAA guidelines in effect on the date of this inspection.
Signed Date Iv 6
Company
Receipt No. 7 q L(qp
Date of Payment S - DU -V�-
Amount: $ < - c)0
Page 2 of 2
72026 411.80
MOA No.
`w N. ♦ e
OF /ki It
*:.490
2225-E
25.1971
Engineer's Seal
3 W 15th AVE **C*'SUITE 203
/ •� U O �' " �+U V �P� WU�1��:1 V ��) PO O � 20ANCHORAGE. ALASKA 99501
•• .CONSULTING ENGINEER TELEPHONE: (9071279-3916
S E P T I C S Y S T E M A D E Q U A C Y T E S T
— — — — — — — — — — — — — — — —
LEGAL:
LOCATION:
OWNER:
RESIDENCE:
WATER SYSTEM:
SEP.TI,C j b,YSTEM:
40
No. 2225-E n
� •,� J:N: aJ. 1971 :qui
f4�)XC cE OF PP
LOT 7, BLOCK 2, GREENBROOK
12840 VAN SCHEBEN
JACK WEAVER
SINGLE FAMILY, FOUR BEDROOMS
CLASS A COMMUNITY SYSTEM
FROM MUNICIPAL RECORDS:
TANK: ANCHORAGE
1250 GAL.
ABSORPTION SYSTEM:
ABSORPTION AREA:
SOIL RATING:
INSTALLATION DATE:
TANK, STEEL, TWO COMP.
TRENCH
504 SQ. FT.
125
MAY 1981
MAY 17, 1986 ANCHORAGE CESSPOOL PUMPING
MAY 16, 1986
TEST PROCEDURE: SYSTEM WAS INSPECTED AND MEASURED. TANK WAS
FOUND WITH FOUR FEET OF COVER. LIQUID DEPTH
WAS 50.5 INCHES. CLEANOUT WAS FOUR FEET DEEP.
HEIGHT ABOVE CROUND 16 INCHES.
SUMP WAS 7 FEET DEEP, WITH FOUR INCHES OF WATER. HEIGHT ABOVE
GROUND WAS 18 INCHES.
WATER WAS ADDED TO THE TRENCH CLEANOUT AT A CONSTANT RATE OF 9.5
GALLONS PER MINUTE. THE WATER LEVELS IN THE TANK AND TRENCH SUMP
WERE MONITORED. A TOTAL OF 700 GALLONS WERE ADDED. DURING THE
FIRST 550 GALLONS NO RISE WAS NOTED IN THE SUMP. THEN DURING THE
LAST 200 GALLONS THE LEVEL ROSE 10 INCHES. NO RISE WAS NOTED IN
THE SEPTIC TANK.
THE INFILTRATION RATE WAS MONITORED FOR 45 MINUTES. DURING THIS
PERIOD A TOTAL OF 62.5 GALLONS WERE ABSORBED. BY EXTENDING THE
OBSERVED INFILTRATION RATE A TOTAL ABSORPTION RATE OF 1000
GALLONS PER DAY WAS ARRIVED AT.
TEST RESULT: THIS SYSTEM MEETS THE CODE REQUIREMENTS OF
THE MUNICIPALITY OF ANCHORAGE.
The operational life of all septic systems depends on the local
soil conditions, groundwater levels that may fluctuate during the
year, and the water usage of the family being served by the
system. These conditions are outside the control of the evaluator
of this septic system. We can therefore not give any estimate of
how long the system will continue to meet the operational requi-
rements of the Municipality and State.
DEPT. OF ENVIRONMENTAI.CONSERTIATION
ANCHORAGE/WESTERN DISTRICT OFFICE
437 "E" STREET, SUITE 3O3
ANCHORAGE_, ALASKA 99501
DATE: M,v 1 S 198E
PWS I.n.N 210346
To Whom it May Concern:
BILL SHEFFIELD, GOVERNOR
Telephone: !9071
Address:
274-2533
According to records on file in this office the GREENBROOK
Water Regulations
Water System is in compliance with the State Drinking
Sincerely,
lvlzc / '
tlichael P. Lewis
Environmental Engineer
1", n
MUNICIPALITY OF ANCHORAGE
DIVISION OF ENVIRONMENTAL HEALTH
DEPARTMENT OF HEALTH AND ENVIRONMENTAL PROTECTION
APPLICATION FOR HEALTH AUTHORITY APPROVAL CERTIFICATE
1. General Information Application Date 1/ V
(a) regal Description (include lot, block, subdivision, section, township, range)
J
(b) Applicants Name
i pplicarts M(;;
.i.
(c) Applicant is,(;
Buyer [::� ; .Ot
Lending Institution
(explain);
2 ner/builder �;
(d) Lending Institution Telephone
Address
(e) Real Estate Co. s Agent 14
Address
Telephone
2. Type of residence
Single -Family Multi -Family
Number of Bedrocros
other (describe)
3. Water Supply 1A
, /I
Individual Fbli Ccmmnityf5<-1 Public
Note: If eom arity well system, must have written ecnfirmation from the State
Department of Environmental Conservation attesting to the legality and status.
Is the well adequate for the number of bedrooms specified in this HAA AN)
4. Sewage Disposal
Orsitey Public Ccmelnity Folding Tark
Is the wastewater disposal system adequate for the number of bedrooms Y )
(Page 1 of 21
2-15-84
/. 7
n
5. Engineering Firm Providing Inspections, Tests, Data and Information
I certify that I have c#iecked, verified, or eonforried to all MSA HAA Guidelines in
effect on the date of this inspection.
ICIL
Name of
Address 1210) /i% . =3sz-1 2% 63
Signed by
Date ` fr Y `l
(ENGINEER SEAL)
Approved for 47" bedrooms By
Date ��IIF"-
'L. Cls ct^a.Gt
Approved Disapproved Q Conditional
Terms of Conditional ARproval
Sr C. a" Jr.
No. !2414
Date a -, olS[
The Municipality of Anchorage Department of Health and Environmental Protection does
not guarantee the continued satisfactory performance of the water supply and/os the
wastewater disposal system. This approval indicates that, as of the validation date
sham above, used on the data and information furnished by an engineer registered in
the State of Alaska, the water supply and wastewater disposal system is safe and func-
tional for the number of bedrooms and type of structure indicated.
(DHEP SEAL)
7. Mail the HAA to the following address:
C�cLCf Cl:. -c ba o�-
RB2/d5/s
[Page 2 of 21
2-15-84
A. WELL DATA
MUNICIPALITY OF ANCHORAGE (MOA)
HEALTH AUTHORITY APPROVAL (HAA)
MUNICIPALITY OF ANCHORAGE
DEPT. OF HEALTH &
ENVIRONMENTAL PROTECTION
Jull 1 Z' SeA;'
CHECKLIST - FEBRUARY 1984 R E C H V E D
Legal Description: L ?L d 2 G;aAeoo K
Well Class ificationC'QM� If A, B, Cr C, D.E.C. Approved(Y ) 31 . '
Well Log Present (Y/N) Iy /it Date Completed N //I Yield
Total Depth AJ 1A Cased to Dep outing
Static Water Level AJ /n Rump Set At ,a!/4
Casing Height Above Ground .I/Q Sanitary Seal on Casing (Y/N
Electrical Wiring in Conduit (Y/N) �AIIA- Depression Around Wellhead (Y
Separation Distances frau Well: �1
To Septic/Holding Tank on Lot 2001-4— On Adjoining Lots
To Nearest Edge of Absorption Field on Lot On Adjoining Lots_&/A_
To Nearest Public Sewer Line To Nearest Public Sewer
Cleanout/Manhole To Nearest Sewer Service Line on Lot /U*%
Water Sample Collected By A/ -
Date
Water Sample Test Results A &
Comments nl/
B. SEPTIC/HOLOING TANK DATA
Date Installed 3 / Size 12,5-6 No. of Compartments `L
Standpipes ((j'N) Air -tight Caps (VN) Foundation Cleanout & N)
Depression over Tank (YVb Date Last Putmped m/ �/ �$�/ U/�/55AC5 L_
Pumping/Maintenance Contract on File (Y/N) P I&for
Holding Tank High -Water Alarm (YIN) Temporary Holding Tank Permit (YIN) Al/a
Separation Distances frau Septic/Hol ng Tank:
To Water -Supply Well ?-On14-To Building Foundation '$')�/b t zwr.
To Property Lire 1-20" To Disposal Field /D 40 -
To Pmsf ice Lire d -/ To Stream, Pond, Lake, or Major Drainage
Cattfsa
..... /� 1 I `1
L CIA UM n.nLie-4-f - 4,AA fnr�
[Page 1 of 21 b
2-15-84
C. ABSORPTION FIELD DATA
Soils Rating in Absorption Strata 1 25 a Type of System Design t PeNc N
Date Installed V/4/81 length of Field 4.2
Width of Field 4� Depth of Field
Gravel Bed Thickness G�
Square Feet of Absorption Area 5-04 Standpipes Present &I)
Depression over Field (y4pk Date of Last Adequacy TestI4ZA(t
Results of Last Adequacy last - �7
Separation Distance from Absorption Field:
To Water -Supply Well 4- To Property LineaE-
To Building Foundation 3cr,S ' �t- To Existing or Abandoned System on
Lot�]y'�`�' ; On Adjoining Lots �[�� r- *
To Water Mair4%ervice Line -t- 10 "f To Cutbank(if present) ill /A
To Stream/Pond/Lake/or Major Drainage Course P 1A—
To Driveway, Parking Area, cr Vehicle Storage Area
rIA
D. LIFT STATION — �JC)JUt✓
J
Date Installed A-) / A . Dimensions
Size in Gallons AfJA Manhole/Access (YIN) Jul/A
"Pump On" level at NTn "Rmg Off" Level at
High Water Alarm level at A//d Vent (Y/N) N/A
Tested for AIIA Pumping Cycles during Adequacy Mast. Meets MDA
Electrical Codes
CLUIT nts
** Check Permitted Bedroan Rating Against HAP. Request **
I cert
on the
that I have checked, verified, or oonfcrmed to all MOA HAA Guidelines in effect
e of this inspection.
KBl /d5/s
(Page 2 of 21
Date
MOA No.
2-15-84
ALASKA bUIROf1 nTAL COnTROL SCRuICCS, InC.
Engineerinq 6 Enuironmental Studies
JUNE 1 1984
BART RICHARDSON
12840 VONSCIDFN DRDIVE
ANCHORAGE AR 99516
SELLER — BART RICHARDSON BUYER —
SUBDIVISION — GREE HOOK BLACK — 2 LOT — 7
ADEQUACY TEST FOR SEWER SYSTEM
THE TYPE OF ABSORPTION SYSTEM IS A TRENCH WITH AN AREA OF 504 SQFT.
THE SYSTEM IS CAPABLE OF ACCEPTING 600 GALLONS OF WATER PER DAY.
THE SURGE CAPACITY OF THE SYSTEM IS 800 GALLONS.
BASED UPON THE TEST DATA THE SYSTEM IS ACCEPTABLE FOR A
4 BEDROOM HOME.
THE SEPTIC TANK TAW PLWED 10a-6 4848 '
SEPTIC TANK ADEQUACY
THE EXISTING SEPTIC TANK VOLUME OF 1250 ADEQUATE FOR
THIS 4 BEDROOM HOUSE.