To Whom it May Concern,
After a thorough inspection, by a qualified electrician, of the waste lift
station and controller at 12101 Wagner St., Anchorage, Alaska. It was
determined that everything is in good working order and conductors
are properly sized. All connections are tight and all appears to be
correct and is functioning properly.
Thank you,
Kent Liska
Superintendent/JM Electrician
UBMIY
Inspection Report_1-1-12.doc
Municipality of Anchorage
Community Development Department DKgi 0 2ofi3 3
On -Site Water and Wastewater Program
4700 Elmore St. • P.O. Box 196650 Anchorage, AK 99519-6650 • http://Www.muni.org/onsite • (907) 343-7904
ON-SITE WASTEWATER INSPECTION REPORT
Permit Number: OSP121394
PID Number: 015-282-21 ❑ New ❑✓ Upgrade
Name:
Mark & Tamara Potter
ABSORPTION FIELD
❑ Deep Trench [E Shallow Trench El Bed El Mound
Address
12101 Wagner Street
❑ Other
Phone
Number of Bedrooms
Soil Rating
Total depth from original grade
3
2 GPD/SF
+0.5 Ft.
LEGAL DESCRIPTION
Depth to pipe invert from original grade
+1.0 Ft.
Gravel depth beneath pipe
I 0.5Ft.
Subdivision
Block Lot
Thomas L Boyle
2 4A
Fill added above original grade
3.5 Ft.
Gravel length
65 Ft.
Township Range Section
Gravel width
5Ft,
Beds: Number of Lines
n/a
Distance between lines
n/aFt.
SEPARATION DISTANCES
To
Septic
Absorption
Holding
Sewer
Total absorption area
Number of trenches
Dist. between trenches
From
Tank
Field
Lift Station
Tank
Line
325 Ft'
1
n/aFt.
Well
102.5
113.9
102.5
N/A
79,3
TANK ❑ Septic O S.T.E.P. ❑ Holding ❑ Other
Manufacturer
Anchorage Tank / Orenco
Capacity
1500Gal.
Surface water
100+
100+
100+
N/A
Material
Number of compartments
Lot Line
27.5
16.0
27.5
N/A
Plastic
2
NA
Foundation
23.6
39.0
23.6
N/A
LIFT STATION
Manufacturer
Capacity
Curtain Drain
N/A
N/A
NIA
N/A
Orenco
5000al.
Remarks
Pump on level at
43 in,
Pump off level at
40 in.
High water alarm at
45 in.
Pump make and model
p2005
Electrical Inspections performed by
Installer
PIPE MATERIAL Housetotank 3034 Tankto drainfield 3034
_
Homeowner / A+ Home Services
Draingeld 3034 CO/MT 3034
Inspector Pannone Engineering Services
BENCHMARK (Assumed elevation) 100ft
Inspection 1•r 5/21/2013
dates: z 6/2/2013
Location and description
30 6/5/2013
4'" 6/7/2013
Garage FF
COMMUNITY DEVELOPMENT DEPARTMENT APPROVAL
Engineer's Stamp
Owl
Conditional Approval:
DateOF'��
" �tevEn 1�� ` annome�
Approved
Date
CE 814
Inspection Report_1-1-12.doc
(E)
W ..
NEW DRAIN FIELD
65LFx5'WxO.5'ED, +0.5' TO
WITH 1.5' SAND
WELL (E)
NOTES:
PLAN
TH-1
—� 17.5 % y
M1 Cs/ 113.9
/ ...
ss
16.0 T1
Me/ 102.5
0' C2 FC A 4 BR
'O HOUSE (E) 4A WELL (E)
DRIVEWAY B
1250g SEPTIC TANK
ABANDONED PER CODE
1 �z NEW 1500g S.T.E.P. TANK
\W/ AX20 POD
INSTALLED DOUBLE CLEAN OUT
DRAIN FIELD (E)
IN FAILURE
RE—USE AS RESERVE>p1 .q1
W_�
'7i
5A 3
PAP.DNNOoozE7 ENGVC, sssLi oC �E OF A�q�s11
PHONE (907) 272-8218 FAX (907) 272-8211
THOMAS L. BOYLE, BLOCK 2, LOT 4A
MARK & TAMARA POTTER
12101 WAGNER STREET
ANCHORAGE, AK 99516
•Steven A.•Pannone•
f PF•. CE 8149 �,�e�
Dote
Scale
1 "=50'
P.I.D. NO
2 OF
A
B
FC
2.1
T1
25.8
46.3
LS
34.1
56.4
C 1
41.4
64.7
M1
44.1
65.9
C2
87.2
97.2
M2
85.0
96.0
TH-1
—� 17.5 % y
M1 Cs/ 113.9
/ ...
ss
16.0 T1
Me/ 102.5
0' C2 FC A 4 BR
'O HOUSE (E) 4A WELL (E)
DRIVEWAY B
1250g SEPTIC TANK
ABANDONED PER CODE
1 �z NEW 1500g S.T.E.P. TANK
\W/ AX20 POD
INSTALLED DOUBLE CLEAN OUT
DRAIN FIELD (E)
IN FAILURE
RE—USE AS RESERVE>p1 .q1
W_�
'7i
5A 3
PAP.DNNOoozE7 ENGVC, sssLi oC �E OF A�q�s11
PHONE (907) 272-8218 FAX (907) 272-8211
THOMAS L. BOYLE, BLOCK 2, LOT 4A
MARK & TAMARA POTTER
12101 WAGNER STREET
ANCHORAGE, AK 99516
•Steven A.•Pannone•
f PF•. CE 8149 �,�e�
Dote
Scale
1 "=50'
P.I.D. NO
2 OF
M
TH-1
—� 17.5 % y
M1 Cs/ 113.9
/ ...
ss
16.0 T1
Me/ 102.5
0' C2 FC A 4 BR
'O HOUSE (E) 4A WELL (E)
DRIVEWAY B
1250g SEPTIC TANK
ABANDONED PER CODE
1 �z NEW 1500g S.T.E.P. TANK
\W/ AX20 POD
INSTALLED DOUBLE CLEAN OUT
DRAIN FIELD (E)
IN FAILURE
RE—USE AS RESERVE>p1 .q1
W_�
'7i
5A 3
PAP.DNNOoozE7 ENGVC, sssLi oC �E OF A�q�s11
PHONE (907) 272-8218 FAX (907) 272-8211
THOMAS L. BOYLE, BLOCK 2, LOT 4A
MARK & TAMARA POTTER
12101 WAGNER STREET
ANCHORAGE, AK 99516
•Steven A.•Pannone•
f PF•. CE 8149 �,�e�
Dote
Scale
1 "=50'
P.I.D. NO
2 OF
SPECIAL PROVISIONS TO SPECIFICATIONS
1. ALL CONSTRUCTION WAS INSTALLED AS SPECIFIED IN THE MOST CURRENT EDITION OF THE MUNICIPALITY OF ANCHORAGE
STANDARD SPECIFICATIONS (MASS) FOR COMPONENT PARTS AND MATERIALS USED IN CONSTRUCTION OF ON—SITE
WASTEWATER DISPOSAL SYSTEMS.
2. SCOPE OF WORK: INSTALLED NEW 1500g S.T.E.P. TANK WITH AX20 POD, AND SOIL ABSORPTION SYSTEM.
3. GROUNDWATER WAS MONITORED AT 3.5 FEET BELOW EXISTING GRADE AS EVIDENCED BY THE SOIL TEST HOLE, AN
APPARENT WATER TABLE WAS NOT OBSERVED IN ANY OF THE EXCAVATIONS LESS THAN 3.5 FEET BELOW EXISTING
GRADE.
INSULATION
ER FABRIC
" 0 DRAIN PIPE
ROCK 6" ABOVE PIPE INV
NEW 1500 g
S.T.E.P. TANK
DESIGN PARAMETERS
PRIMARY/RESERVE SEPTIC SYSTEM
NO. BEDROOM: 4 (600 gpd)
TANK SIZE: 1500g S.T.E.P.
W/ AX20 POD
PERC RATE = 47.6 MPI
SOIL RATING: 2.0 GPD/SF
AREA ROD: 300 SF
SYS. TYPE: WIDE TRENCH 0.5' E.D.
MIN LENGTH: 60 LF
USED:
65 LF X 5' WIDE, 0.5' E.D., +0.5' TD
WITH 1.5' SAND
TOTAL AREA: 325.0 SF
SEE SECTION & PARAMETERS
PROFILE
LEGEND
W WATER LINE/
WELL RADIUS
— SS — NEW SEPTIC
ABBREVIATIONS
CU
COPPER
3
2.0
� 6" TS&V
TEST HOLE
FC
FOUNDATION CLEAN OUT
T#
TANK CLEAN OUT NO.
1
0.5
CLEAN OUT NO.
M#
MONITOR TUBE NO.
TH-i
D'S 975
98.0
DOUBLE CLEAN OUT
',�'
-1 0
FS
� 97.0
0.5 961.0„„.;;-
BFG
BELOW FINISH GRADE
OG
4 0
FG
DRAIN ROCK
TS&V
TOPSOIL & VEGETATE
4
SM, -
REMOVE ORGANICS
ML -3.5 (10/23/2012)
PLACE 1.5t SAND
-6.0
SECTION
z
o;
o
w
jZ
w
60 O
z�
F
N
rci
RIGID INSULATION
m0
�_
OJ
_�
J
FILTER FABRIC
��
F.102.?,
O�
¢
DRAIN ROCK 6” ABOVE PIPE INV
llrir'�4"
o�
�1
-I I�
D
0 DRAIN PIPE
D
NEW 1500 g
S.T.E.P. TANK
DESIGN PARAMETERS
PRIMARY/RESERVE SEPTIC SYSTEM
NO. BEDROOM: 4 (600 gpd)
TANK SIZE: 1500g S.T.E.P.
W/ AX20 POD
PERC RATE = 47.6 MPI
SOIL RATING: 2.0 GPD/SF
AREA ROD: 300 SF
SYS. TYPE: WIDE TRENCH 0.5' E.D.
MIN LENGTH: 60 LF
USED:
65 LF X 5' WIDE, 0.5' E.D., +0.5' TD
WITH 1.5' SAND
TOTAL AREA: 325.0 SF
SEE SECTION & PARAMETERS
PROFILE
LEGEND
W WATER LINE/
WELL RADIUS
— SS — NEW SEPTIC
ABBREVIATIONS
CU
COPPER
DIP
DUCTILE IRON PIPE
TH
TEST HOLE
FC
FOUNDATION CLEAN OUT
T#
TANK CLEAN OUT NO.
C#
CLEAN OUT NO.
M#
MONITOR TUBE NO.
R.I.
RIGID INSULATION
DCO
DOUBLE CLEAN OUT
DV
DIVERTER VALVE
FS
FLOW SPLITTER
BFG
BELOW FINISH GRADE
OG
ORIGINAL GRADE
FG
FINISH GRADE
TS&V
TOPSOIL & VEGETATE
NOTES:
Pt1lV1`IONL' ENG SVC, LLC�
P.O. BOX 100217 ANCHORAGE, AK 99510
PHONE (907) 272-8218 FAX (907) 272-8211
~OF A`.,q
(�•• s`��
/�GU�P Fyt�
�..... ..... ... .�
• • Steven •R• •Pannone'
.•. CE 8149
�+ �s ., � r
�I�IEDq��pPp�
Date
9/1s/zo12
RECORD DRAWING
Scale
NTS
THOMAS L. BOYLE, BLOCK 2, LOT 4A
MARK &TAMARA POTTER
12101 WAGNER STREET
ANCHORAGE, AK 99516
P.I.D. NO
15-282-21
PERMIT N0.
OSP121394
DESIGN DETAILS
sheet
3 OF 3
On -Site Wastewater Disposal System Permit
MUNICIPALITY OF ANCHORAGE
Development Services Department
On -Site Water & Wastewater Program
4700 Elmore Road, PO Box 196650
Anchorage, AK 99519-6650
Telephone: (907) 343-7904
Permit Number: OSP121394
Tax Code Number: 01528221000
Work Type: Septic Upgrade
Permit Effective Dates: November 08, 2012 to November 08, 2013
Design Engineer: PANNONE ENGINEERING SERVICE
Subdivision: THOMAS L BOYLE
Site Legal Address: THOMAS L BOYLE BILK 2 LT 4A G:2734
Owner/Address: POTTER MARK C & TAMARA JO
12101 WAGNER STREET ANCHORAGE AK 995162024
Site Mailing Address: 12101 WAGNER ST, Anchorage Lot Size in Sq Ft: 49500
Total Bedrooms: 4
This permit is for the construction of: _
Y Disposal Field Y Septic Tank N Holding Tank N Privy N Private Well N Water Storage
All construction must be in accordance with:
1. The attached approved design.
2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater
Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80).
3. The wastewater code requires inspections during the installation. The engineer must notify the Development Services
Department at least 2 hours prior to each inspection. Provide notification by calling (907) 343-7904 (24 hours).
4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must either.
A. Open and Close on the same day.
B. Covered, sealed, and heated to prevent freezing.
Received
Issued By:ylU�eE�/ (N�v� �L Date: I/ t3 1---
MUNICIPALITY OF
Community Development Department
Development Services Division
On -Site Water & Wastewater Program
Phone: 907-343-7904
Fax: 907-343-7997
ON-SITE SEWERIWELL PERMIT APPLICATION
Parcel I.D. 015-282-21
Property owner(s) Mark & Tamara Potter Day phone
Mailing address 12101 Wagner Street, Anchorage, AK 99516
Site address 12101 Wagner Street
Legal description (Sub'd., Block & Lot) Thomas L. Boyle, Block 2, Lot 4A
Legal description (Township, Range & Section)
Lot Size 49,500 Sq. Ft. Number of Bedrooms 4
APPLICATION IS FOR:
APPLICATION IS AN: TYPE OF DWELLING:
(® all that apply)
Absorption Field ❑x
Initial ❑ Single Family (SF)
❑X
Septic Tank ❑X
Upgrade FX_1 (w/wo ADU)
Holding Tank El
(D) Renewal ❑
Renewal
❑
Privy ❑
Multiple Dwellings
❑
(SF and/or D)
Private Well ❑
Water Storage ❑
THIS APPLICATION INCLUDES
A VARIANCE / WAIVER REQUEST FOR:
Distance:
I certify that the above information
is correct. I further certify that this is in accordance with
applicable Municipal Codes.
(Signature of property owner or authorized agent)
Permit/Rush Fees: 530
Date of Payment: (O 13011
Receipt Number: U J G1
Permit No. CJP�ae�J�'1
Permit App_'.:-:. :
Waiver Fees:
Date of Payment:
Receipt Number:
Waiver No.
Pannone Engineering Services uc
Steven R. Pannone, Principal
Registered Professional Engineer
E-mail: steve@paneneak.com
October 29, 2012
Municipality of Anchorage
Development Services Department
On -Site Water & Wastewater Program
4700 S. Bragaw Street
P. O. Box 196650
Anchorage, Alaska 99519
Subject: Thomas L. Boyle, Block 2, Lot 4A
Septic System Permit Upgrade Request
Ladies and Gentlemen:
I am writing to request a permit to upgrade the septic system be issued for this property. The proposed
systems will serve an existing four (4) bedroom house. Currently the lot is developed. The existing drain
field is in failure and will be reused as a 4 bedroom reserve. The existing septic tank and will be
abandoned per code, and a new 15008 S.T.E.P. tank with AX20 Pod will be installed. This lot is served by a
private well that is located over 100 feet from this system. The surrounding developed lots are also served
by private wells. There are no wells within 100 feet of this system.
1. Soils. A single test hole was excavated by Pannone Engineering Services in October of 2012, and
the ground water monitored for seven days. Groundwater was observed at 3.5' in the test hole monitor
tube after the seven day monitoring period. Bedrock was not encountered in the test hole. It is my
opinion, based on the results of the percolation tests and overall soils appearance; an application rate of 2
gallons/day/square feet should be used for a CAT III wastewater system.
2. Soil Absorption System Design.
a. See Sheet 2 of the design package.
3. Surface Water: There is no surface water within 100 feet of the proposed septic tank and drain
field. The proposed drain field upgrade will maintain at least 100 feet from all surface water and drainage
ditches.
4. Topography: The topography slopes from southeast to northwest at approximately 4%- 5% in
the area of the proposed drain field. There are no steep slopes in the area.
5. Drawing Markings: The Drawings are marked "For MoA Review Only'. When written notification
that the review is complete and that there are no further comments is received from MoA On -Site
Mailing: P.O. Box 100217, Anchorage, AK 99510-0217
Physical: 332 East Manor, Anchorage, AK 99501.
Telephone: (907) 272-8218 FAX: (907) 272-8211
Page 2 of 2
Department, the note will be removed and "Issued for Construction" drawings will be issued.
The proposed installation will not affect the future development of the surrounding or existing lots. There
are no wells or septic systems within 100 feet of the proposed septic location.
If you have any questions or concerns, please contact me at 272-8218.
Sincerely,
Steven R. Pannone, P.E.
Owner/Civil Engineer
Attachments
-Soils Log
-Septic System Design
Mailing: P.O. Box 100217, Anchorage, AK 99510-0217
Physical: 332 East Manor Ave, Anchorage, AK 99501
Telephone: (907) 272-8218 FAX: (907) 272-8211
'ELL (E)
W�
B
DRAIN FIELD (P) 118.8
60LFx5'WxO.5'ED, +0.5' TO T —1 ss
WITH 1.5' SAND 19.5 99.9
(3
4 BR
OUSE (E)
4A WELL (E)
'41
DRIVEWAY
1250g SEPTIC TANK (E)
w
ABANDON PER CODE
1500g S.T.E.P. TANK (P)
W/ AX20 POD
INSTALL DOUBLE CLEAN OUT
AND DIVERTER VALVE
DRAIN FIELD (E)
IN FAILURE
RE—USE AS RESERVE
W
\N
L WELL"(E)
f
41
xvx
i .9
'77
\N
VV 8
5A
NOTES: PAMONE ING SVC, LLC I o A11\h Date
FOR CONSTRUCTION 11/6/2012
P.O. BOX 100217 ANCHORAGE, AK 99510
PHONE (907) 272-8218 FAX (907) 272-8211 log Scale
TH 1"=50'
..... .. P.I.D. NO
THOMAS L. BOYLE, BLOCK 2, LOT 4A .... .. . P6nnone PERMIT NO.
MARK & TAMARA POTTER Steve R.
12101 WAGNER STREET CE 8149 OSP1 21394
PLAN ANCHORAGE, AK 99516 *
D S'e7t
1 OF 4
SPECIAL PROVISIONS TO SPECIFICATIONS
1. ALL CONSTRUCTION SHALL BE INSTALLED AS SPECIFIED IN THE MOST CURRENT EDITION OF THE MUNICIPALITY OF
ANCHORAGE STANDARD SPECIFICATIONS (MASS) FOR COMPONENT PARTS AND MATERIALS USED IN CONSTRUCTION OF
ON—SITE WASTEWATER DISPOSAL SYSTEMS.
2. ALL WORK SHALL BE IN ACCORDANCE WITH THE ATTACHED SPECIFICATIONS.
3. SCOPE OF WORK: INSTALL NEW 150og S.T.E.P. TANK WITH AX20 POD, AND SOIL ABSORPTION SYSTEM.
4. GROUNDWATER WAS MONITORED AT 3.5 FEET BELOW EXISTING GRADE AS EVIDENCED BY THE SOIL TEST HOLE. IF AN
APPARENT WATER TABLE IS OBSERVED IN ANY OF THE EXCAVATIONS LESS THAN 3.5 FEET BELOW EXISTING GRADE
NOTIFY THE ENGINEER IMMEDIATELY.
INSULATION
ER FABRIC
" 0 DRAIN PIPE
ROCK 6" ABOVE PIPE INV
1500 g S.T.E.P.
TANK (P) W1
AX20 POD
SEE SECTION & PARAMETERS
PROFILE
ABBREVIATIONS
DESIGN PARAMETERS LEGEND
3 2.0
r 0.5
TH-1
PRIMARY/RESERVE SEPTIC SYSTEM W WATER LINE/
_ 3 1 6" TS&V
D.5
NO. BEDROOM: 4 (600 gpd) WELL RADIUS
FC FOUNDATION CLEAN OUT
TANK SIZE: 1500g S.T.E.P.
_1 0
0.5
C# CLEAN OUT NO.
PERC RATE = 47.6 MPI
SOIL RATING: 2.0 GPD/SF
M# MONITOR TUBE N0.
40
R.I. RIGID INSULATION
DRAIN ROCK
DCO DOUBLE CLEAN OUT
MIN LENGTH: 60 LF
DV DIVERTER VALVE
FS FLOW SPLITTER
USE:
BEG BELOW FINISH GRADE
60 LF X 5' WIDE, 0.5' E.D., +0.5' TO
OG ORIGINAL GRADE
WITH 1.5' SAND
FG FINISH GRADE
SM/
TS&V TOPSOIL & VEGETATE
REMOVE ORGANICS
�7� �+7�� LLC
PAM
PAMONE ENG SVC, LLA.
P.O. BOX 100217 ANCHORAGE, AK 99510
PHONE (907) 272-8218 FAX (907) 272-8211
+'pF A x_ kk
.? C� •"
*�P. TH 9*�
.... . .. . ..:..
Date /6/2012
FOR CONSTRUCTION
ML -3.5 (10/23/2012)
Scale
NITS
PLACE 1.5't SAND
THOMAS L. BOYLE, BLOCK 2, LOT 4A
P.I.D. NO
5 282-21
-6.0
MARK &TAMARA POTTER
♦I •Steven f2. *Pannone*
PERMIT NO.
12101 WAGNER STREET
PF •, CE 8149
�� cs . •��
OSP121394
SECTION
Sheet
Z
o7
QO
ANCHORAGE, AK 99516
o
P
w
mo
W
mo
iz
o
w
RIGID INSULATION
�_
z
FABRICr("
�FILTER
ABOVE PIPE INV
/r40
A
FT
n
-_
R
DRAIN PIPE
1500 g S.T.E.P.
TANK (P) W1
AX20 POD
SEE SECTION & PARAMETERS
PROFILE
ABBREVIATIONS
DESIGN PARAMETERS LEGEND
CU COPPER
PRIMARY/RESERVE SEPTIC SYSTEM W WATER LINE/
DIP DUCTILE IRON PIPE
TH TEST HOLE
NO. BEDROOM: 4 (600 gpd) WELL RADIUS
FC FOUNDATION CLEAN OUT
TANK SIZE: 1500g S.T.E.P.
T# TANK CLEAN OUT NO.
W/ AX20 POD SS NEW SEPTIC
C# CLEAN OUT NO.
PERC RATE = 47.6 MPI
SOIL RATING: 2.0 GPD/SF
M# MONITOR TUBE N0.
AREA RQO: 300 SF
R.I. RIGID INSULATION
SYS. TYPE: WIDE TRENCH 0.5' E.D.
DCO DOUBLE CLEAN OUT
MIN LENGTH: 60 LF
DV DIVERTER VALVE
FS FLOW SPLITTER
USE:
BEG BELOW FINISH GRADE
60 LF X 5' WIDE, 0.5' E.D., +0.5' TO
OG ORIGINAL GRADE
WITH 1.5' SAND
FG FINISH GRADE
TOTAL AREA: 300.0 SF
TS&V TOPSOIL & VEGETATE
NOTES:
�7� �+7�� LLC
PAM
PAMONE ENG SVC, LLA.
P.O. BOX 100217 ANCHORAGE, AK 99510
PHONE (907) 272-8218 FAX (907) 272-8211
+'pF A x_ kk
.? C� •"
*�P. TH 9*�
.... . .. . ..:..
Date /6/2012
FOR CONSTRUCTION
Scale
NITS
THOMAS L. BOYLE, BLOCK 2, LOT 4A
P.I.D. NO
5 282-21
MARK &TAMARA POTTER
♦I •Steven f2. *Pannone*
PERMIT NO.
12101 WAGNER STREET
PF •, CE 8149
�� cs . •��
OSP121394
Sheet
DESIGN DETAILS
ANCHORAGE, AK 99516
�,t`FO........
2 OF 4
SOILS LOG - PERCOLATION TEST
TEST HOLE I
SLOPE SITE
PLAN
OR ORGANICS
2— srvv SILTAND
ML SILTY SAND
3—
'7 10123/2012
4— 10/12/2012 TH-1
6— BOH x TH
I BIRD
.E
)S�
)S
HO� E (E) 4A
7 —
'41
.. ....
.. ..
8— DRIVEWAY
9—
af
10
12
13 —
WAS GROUNDWATER
SLOPE
14 — ENCOUNTERED? N
15 — IF YES, AT WHAT
TH
16 DEPTH? -4.Oj
x
17 DEPTH TO WATER AFTER
MONITORING? -3.5�
18 DATE: 10/2312012
DATE PERFORMED: 10112112 READING DATE CLOCK
TIME
WATER
NET TIME LEVEL NETDROP
READING
1 10/23/12 11:15
4.75 -
2 11:45
30 MIN 5.62 0.87
3 11:45
4.75 -
4 12:15
30 MIN 5.38 0.63
5 12:15
4.76 -
6 12:45
30 MIN 5.39 0.64
PEROLATION RATE 47.6 (min/inch)
PERC HOLE DIAMETER 6 inches
TEST RUN BETWEEN 2 FT AND 3 FT
COMMENTS: Test hole excavated by PANNONE ENGINEERING. Prec hole was presoaked.
PERFORMED BY: Steven R. Pannone, P.E. I CERTIFY THAT THIS TEST WAS PERFORMED IN ACCORDANCE
WITH ALL STATE AND MUNICIPAL GUIDLINES IN EFFECT ON THE DATE OF THIS TEST.
NOTES:
PAMOM ING SVC, LLC
P.O. BOX 102954 ANCHORAGE, AK 99510
PHONE (907) 272-8218 FAX (907) 272-8211
. ......
.... .. .. ........
Ste en . onnone
CE 8149
Date
11/6/2012
FOR CONSTRUCTION
Scale
N S
THOMAS L. BOYLE, BLOCK 2, LOT 4A
MARK & TAMARA POTTER
12101 WAGNER STREET
J.D. NO
015-2B2-21
PERMIT NO.
OSP121394
SOILS LOG
ANCHORAGE, AK 99516
Sheet
3 OF 4
4" JIM CAP
4" PUMP—OUT.
SLIDE SECTION
OF 6" PIPE
OVER THIS CONNECTION
TO PROVIDE
SHEER PROTECTION—
EXTEND TO
BRIDGE EXCAVATION
NOTES:
FOR CONSTRUCTION
SITE SECTION
ADVANTEX DESIGN
ADVANTEX 24° PASSIVE
AX20 POD\ INSULATED AUXILIARY AIR
\1 RISER PUMP VENT
BASIN
1500
GALLON
ANCHORAGE
TANK
PANNONE ENG SVC, LLC
P.O. BOX 100217 ANCHORAGE, AK 99510
PHONE (907) 272-8218 FAX (907) 272-8211
THOMAS L. BOYLE, BLOCK 2, LOT 4A
MARK & TAMARA POTTER
12101 WAGNER STREET
ANCHORAGE, AK 99516
Ur Ai 4_e jj 111/6/2012
*; t}9TH •.*1, NTS
... ...... P.I.D. NO
&k5-282-21
Steven F2� annone"� PERMIT NO.
.' CE 8149 �� OSP121394
1��`\R?OFESS10a= Sh4eOF 4
ADVANCED WASTEWATER TREATMENT SYSTEM MAINTENANCE AND
REPAIR AGREEMENT
MEMORANDUM OF UNDERSTANDING
BETWEEN MUNICIPALITY OF ANCHORAGE
AND M a ti �- a; �xVa r -r, v -
T
THIS MEMORANDUM OF UNDERSTANDING made and entered into as of this
7 Day of N Ck1 et —F of 201 , by and between m 0. (- k e PU
herein the "OWNER," and the Municipality of Anchorage, herein the
"MUNICIPALITY." In consideration of the mutual covenants contained herein, the
parties to this Memorandum of Understanding agree as follows:
1. ADVANCED WASTEWATER TREATMENT SYSTEMS. Municipality
grants permission to Owner to utilize and operate an Advanced Wastewater
Treatment System (AWWTS), described as 46611 t/T9X located
at ����� L • UO`iC6' 16/ ii L� L D't Ali'}, Anchorage, Alaska.
2. Definitions.
A. Alteration. Any change to the design or function of an AWWTS that
Includes the installation or removal of any parts, components or pieces not
included in the original construction permit and design. Prior to
performing any alterations to an AWWTS the owner must obtain a
Wastewater Disposal System Construction Permit from the Municipality
pursuant to Anchorage Municipal Code (hereinafter, "AMC") 15.65.
B. Certificate of On -Site Systems Approval. An approval by the
Municipality of existing water and wastewater disposal systems given at
the time of property sale and title transfer in accordance with AMC 15.65.
These approvals certify that the systems are adequate for the homes that
they support and meet the codes that were in place at the time of system
construction.
C. Damage. Any man-made or natural change in a system that would inhibit
the system from performing as designed.
D. Maintenance and Repair. The scheduled and as needed replacement of
existing parts, components and pieces of an AWWTS that were included in
the original design which would allow the AWWTS to continue to
perform as designed.
E. Permit (Construction) An On -Site Wastewater Disposal System
Construction Permit as defined by AMC 15.65.
F. Permit (Operating) An Advanced Wastewater Treatment System
Operating Permit. An annual permit, issued by the Municipality, that
allows the Owner to operate an AWWTS, upon meeting all the
requirements of this agreement, the conditions of Operating Permit, the
requirements of the On -Site Wastewater System Construction Permit and
all relevant provisions of AMC 15.65
3. Fee. Owner shall pay to Municipality an annual fee of
IZ- 5.0—O
($ 0 .00), payable on or before the issuance of the operating permit and annually
thereafter. The annual fee is due on or before the anniversary date of the approval by the
Municipality of installed system.
4. Term. The term of this Memorandum of Understanding shall be for the life of the
AWWTS.
The term begins on the date of approval by the Municipality of the installed system and
shall continue while the AWWTS system is in use or operational or until the property is
sold or title is transferred by owner and a new certificate of On -Site approval is issued to
the new owner or transferee of the property.
5. Alterations, Installation and Removal of Additional Eauipment. Owner agrees
not to make any alterations, removal of parts or additions to the AWWTS without a
Construction Permit from the Municipality.
6. Maintenance and Repairs.
A. Throughout the term of this Memorandum of Understanding, the Owner shall
maintain AWWTS in good repair. In addition, it shall be the responsibility of the
Owner during the term of this Memorandum of Understanding, and any extensions or
renewals thereof, at the owner's sole expense, to pay for any and all: (1) repair(s), (2)
maintenance, (3) adjustment(s), (4) replacement costs, and (5) inspection costs.
Further, Owner agrees to comply will all applicable ordinance, laws, regulations,
rules and orders for the AWWTS.
B. Owner agrees to provide the Municipality a written schedule of routine
maintenance and repairs which have been performed on the system pursuant to the
terms and conditions contained in the Owner's AWWTS Operating Permit. This
schedule shall be submitted to the Municipality annually upon the renewal of the
permit. The schedule of maintenance and repair contained in the Owner's AWWTS
Operating Permit is: /9-S 9Ea1%96,19
C. Owner acknowledges that the fine schedule for failing to maintain and repair an
AWWTS are codified in AMC 14.60.
D. Owner agrees that only maintenance, repair personnel certified by the
Municipality will inspect and make any necessary maintenance, repairs or permitted
alterations to the system.
E. Owner agrees to grant the Municipality reasonable access to test and inspect the
AWWTS upon 24 hours written notice.
F. Owner agrees that any sale or transfer of title of the property will not occur
without a new Certificate of On -Site Systems Approval.
G. Owner agrees that the relevant provisions of the standard specification guidebook
for AWWTS is the governing professional guidelines for the construction,
maintenance and repair of the Owner's AWWTS.
7. Nonwaiver. The failure of either party at any time to enforce a provision of this
Memorandum of Understanding shall in no way constitute a waiver of the provisions,
nor in any way effect the validity of the Memorandum of Understanding or any part
hereof, or the right of such party thereafter to enforce each and every provision
hereof.
8. Amendmeut.
A. This Memorandum of Understanding shall only be amended, modified or changed
by a writing, executed by authorized representatives of the parties, with the same
formality of this Memorandum of Understanding was executed and such writing shall
be attached to this Memorandum of Understanding as an amendment.
B. For the purposes of any amendment modification or change to the terms and
conditions of this contract, the only authorized representatives of the parties are:
Owner: V�
Anchorage: Purchasing Officer
C. Any attempt to amend, modify, or change this contract by either an
unauthorized representative or unauthorized means shall be void.
9. Jurisdiction: Choice of Law. Any civil action arising from this Memorandum of
Understanding shall be brought in the Superior Court for the Third Judicial District of the
State of Alaska at Anchorage. The laws of the State of Alaska shall govern the rights and
obligations of the parties under this Memorandum of Understanding.
10. Severability. Any provisions of this Memorandum of Understanding decreed
invalid by a court of competent jurisdiction shall not invalidate the remaining provisions
of the Memorandum of Understanding.
OWNER:
MUNICIPALITY:
�—
By: �C�yr-tea
( Title:
Date: (l I a Date:
STATE OF ALASKA }
ss.
THIRD JUDICIAL DISTRICT )
The foregoininstrumentvas acknowledged before me this day of /Ulf.
20L by 1, IJ MtiCe e o f Dtu-
,..I...."""•
NOTARY PUBLIC FOR ALASKA
`i• ¢ ,, ati
My Commission exp�&a:Ellen Patterson
My Commission Expires 3/26/2016 p o°`
�S ZQ'1�tt•:
'1. ane .�•a•
MUNICIPALITY OF ANCHORAGE
•.` DEPARTMENT OF HEALTH & ENVIRONMENTAL PROTECTION
ENVIRONMENTAL ENGINEERING DIVISION
*01
11 825 L Street. Anchorage, Alaska 99501 Telephone 264-4720
ONSITE SEWAGE DISPOSAL SYSTEM AND/OR WELL INSPECTION REPORT
NAMEPHONE
(1(', NEW
Jerome Bauer
243-1596
❑UPGRADE
MAILING ADDRESS
4300 Arctic #54, Anchorage, Alaska 99503
LEGAL DESCRIPTION
Lot 4A, Block 2, Boyle Subdivision
LOCATION
NO. OF BEDROOMS
Wagner Road off Huffman
3
DISTANCE TO:
Well 100'
Abslrpson area
1
Dwellilq s
`!
PERMIT NO.
V Y
800 180
2
Manufacturer
Material
No. of compartments
W <
Greer
Steel
2
Liq, capacity in gallons
1000
IF HOMEMADE:
Inside length
Width
Liquid depth
6Y
DISTANCETO:
Well
Dwelling
PERMIT NO.
l7Z
Z'4
=
Manufacturer
Material
Liquid capacity in gallons
0
w=
DISTANCE TO:
Well
Foundation
Nearest lot line
PERMIT NO.
1151
s
,
Boo Igo
u Z
z
No. of lines Length of each line
4
Total len th of lines Trench width
Distance between lines
P
40'
160 36 inches
69
f
Top of the to fila"nish grt0
Material beneath lila
Total effective absorption area
o¢
24"
8 inches
ranch 480 ft Ptotmd 268
W
Length Width
Depth
PEHMIT NO.
a F-
W Is.
Type of crib
Crib diameter
Crib depth
Total effective absorption area
DISTANCE TO:
Well
Building foundation
Nearest lot line
J
Class
Depth
Driller
Distance to lot line
PERMIT NO.
J
W
i
DISTANCE TO:
Building foundation
Sewer line
Septic lank
Absorption area(s)
OTHER
S
e
tt
Ch
d
pages
or
AS
BU
It
PIPE MATERIALS
4" Perforated PVC
set
h.
SOIL TEST RATING
330 sq. ft./ B.R.
INSTALLER
Jerome BaVer
REMARKS
As -Built Inspection performed on
November 15, 1980 by RSM Consultants,
Inc.
Richard S. Giessel,
Staff Engineer
+H+
APPROVED DATE LEGAL
- MIJt+I I C I PSL I TY OFF1tJCH�RFiICaE �lOr f�
DEPARTMENT C 'HEALTH AND ENVIRONMENTAL 7TECTION /u
�' • 825 'L' STREET, ANCHORAGE, AK. 99501
• 264-4720
Hnr-4E >WR I TTEM PERM I T
A COPY MUST BE OBTAINED FROM THE FILES - DATA NOT AVAILABLE IN THE COMPUTER
F.e,e.H,T $1 tF- 00/fo
7'0
6-2
P -*-Port iT EKI.71geL
A// Nr v iv, c//�4 /
12/3i/dro
J- 7
v'E�koML AM,
MU" I C I 1-^F7L I TY OF nNCHJRFIGE
DEPARTMENT OF HEALTH AND ENVIRONMENTAL PROTECTION
825 'L' STREET, ANCHORAGE, AK. 99501
264-4720
W E L L A M O CD R7— S I T E S E W E R F='[=-: R M I T
PERMIT NO. ( 800080 )
APPLICANT JEROME BAUER 4300 ARCTIC BOULEVARD #54 9950 279-1678
LOCATION HILLSIDE
LEGAL jLOT 2'BLOCK %4WBOYLE S, -'D --j4 ` O I LrLT- SIZE 49500 SQUARE FEET
HA _ _ .__...__a iv)
TYPE OF SOIL ABSORPTION SYSTEM IS: TREKi
MAXIMUM NUMBER OF BEDROOMS = 3 SOIL RATING (SQ FT/BR)= 225
THE REQUIRED SIZE OF THE SOIL ABSORPTION'SYSTEM IS
DEPTH= 12 L_EtJGTH= 4so �GRAtirEL_ DEPTH=
THE LENGTH DIMENSION IS THE LENGTH CIN FEET) OF tHE TRENCH OR DRAINFIELD.
THE DEPTH OF A TRENCH OR PIT IS,THE!DISTANCE BETWEEN THE SURFACE OF THE
GROUND AND THE BOTTOM OF THE EXCAVATION CIN FEET>. ",,
THERE IS NO SET WIDTH FOR,TPENCHES. r"
THE GRAVEL DEPTH IS THE MINIMUPIJDEPTH OF GRAVEL BETWEEN THE OUTFALL PIPE
AND THE BOTTOM OF"THE EXCAVATION CIN FEET).
REQU I REG SEP?' 10 }TFit-4K S I E= 1000 (3n L_ _C3r-4
PERMIT APPLICANT HAS THE RESPONSIBILITY TO INFORM THIS DEPARTMENT DURING THE
INSTALLAT ON INSPECTIONS\OF ANY WELLS ADJACENT TO`THIS PROPERTY AND THE
NUMBER, OF�ESIDENCES THAT+ THE WELL WILL SERVE.
TWO <.;2>,\ 7 tVSP �� Ot+iS. faRE REQU I REG —
BACKFILLING'OF ANY,SYSTE:I T N,C INSPECTION AND APPROVAL BY THIS
DEPARTMENT WILL BE\SUBJE T OS Cly � ON.
MINIMUM\DISTANCE BETWEEN A�WELL AND ANY ON-SITE SEWAGE DISPOSAL SYSTEM IS
100 FEET�POF:�A PRIVATE WELL OR 150 TO 200 FEET FROM A PUBLIC WELL DEPENDING
UPON THETYQE,OF PUBLIC WELL.
MINIMUM DISTANCE FROM A PRIVATE WLL TO A PRIVATE SEWER. LINE IS 25 FEET AND
TO A COMMUNIT'SEWER LINE IS 7�5 FEET)
WELL LOGS ARE\ EQUIRED`AND MUS BE RETURNED TO THE DEPARTMENT WITHIN 30 DAYS
OF THE WELL COMPLETION. , �/ `\
OTHER REQUIREMENTS MAY\APPLY.-•I,$PECIFI TIorontIIj CC J TRUCTION DIAGRAMS ARE
AVAILABLE TO INSURE PROPER,,INSTALLATIOtt l LJ
PERM I T EXP I ES '� DECEMBER 31s 1X843
I CERTIFY THAT ,'"
1: I AM FAMILIAR WITH THE REQUIREMENTS FOR ON-SITE SEWERS AND WELLS AS SET
FORTH BY THE MUNICIPALITY OF ANCHORAGE.
2: I WILL INSTALL THE SYSTEM IN ACCORDANCE WITH THE CODES.
3: I UNDERSTAND THAT THE ON-SITE SEWER SYSTEM MAY REQUIRE ENLARGEMENT IF THE
RESIDENCE IS REMODELED TO INCLUDE MORE THAN 3 BEDROOMS.
--------------------
SIGNED:- -- -
APPLICANT JEROME BAUER ---------------- 010C/ud
ISSUED BY ------------------------------DATE V4.0
MUN I C I PF'tL_ I TY CSF= n"CHORACaE
DEPARTMENT n HEALTH AND ENVIRONMENTAL I`;OTECTION
825 'L STREET. ANCHORAGE, AK. 95..v1
X64-4720
LJELFL "r4l> Oro I TE 'c3EWER PERM I T
PERMIT NO. C >
APPLICANT � P morn � Bl u e r- q" 30 0 /C C C So f
LOCATION
LEGAL 5/b LOT SIZE SQUARE FEET
TYPE OF SOIL ABSORSTION SYSTEM IS: fie-" e,v� dl
MAXIMUM NUMBER OF BEDROOMS - 3 SOIL RATING CSQ FTlBR>- a s
THE REQUIRED SIZE OF THE SOIL ABSORPTION SYSTEM IS:
E> EE: FP' -r"— /), LENGT vlhc3RFivaL_ I?EF"TH= 7
THE LENGTH DIMENSION IS THE T CINIFETT OF THE TRENCH OR DRAINFIELD.
THE DEPTH OF A TRENCH OR PIT IS THE DISTAPiCE BETWEEN THE SURFACE OF THE
GROUND AND THE BOTTOM OF THE EXCAVATION CIN FEET).
THERE IS NO SET WIDTH FOR TRENCHES.
THE GRAVEL DEPTH IS THE MINIMUM DEPTH OF GRAVEL BETWEEN THE OUTFALL PIPE
AND THE BOTTOM OF THE EXCAVATION CIN FEET.
REQU I FZEL> f3EF=^T I C TAFdK S 12: E_ , ba O GF1LL_0r4S
1' PERMIT APPLICANT HAS THE RESPONSIBILITY TO INFORM THIS DEPARTMENT DURING THE
�,,INSTRLLATION INSPECTIONS OF ANY WELLS ADJACENT TO THIS PROPERTY AND THE
'NUMBER OF RESIDENCES THAT THE W L S RVE.
--- TWO C 2 � I tJ�F�EiC I F -o F=IRE REQU I REI?
BACKFILLING OF ANY SYSTEM WITHOUT FINAL INSPECTION AND APPROVAL BY THIS
DEPARTMENT WILL BE SUBJECT TO PROSECUTION.
MINIMUM DISTANCE BETWEEN A WELL AND ANY ON-SITE SE14AGE DISPOSAL SYSTEM IS
100 FEET FOR A PRIVATE WELL; OR
150 TO 200 FEET FROM A PUBLIC WELL DEPENDING UPON THE TYPE OF PUBLIC WELL.
WELL LOGS ARE REQUIRED AND MUST BE RETURNED TO THE DEPARTMENT WITHIN 30 DAYS
OF THE WELL COMPLETION.
OTHER REQUIREMENTS MAY APPLY. SPECIFICATIONS AND CONSTRUCTION DIAGRAMS ARE
AVAILABLE TO INSURE PROPER INSTALLATIO .
PERM I T E:XF= I REQ C�
EC M&I ] s 19 80
I CERTIFY THAT
1: I AM FAMILIAR WITH THE REQUIREMENTS FOR OPI-SITE SE14ERS
FORTH BY THE MUNICIPALITY OF ANCHORAGE.
2: I WILL INSTALL THE SYSTEM IPJ ACCORDANCE WITH THE CODES.
3: I UNDERSTAND THAT THE ON-SITE SEWER SYSTEM MAY REQUIRE
RESIDENCE IS REMODELED TO INCLUDE MORE THAN 3 BEDROOMS.
SIGNED
ISSUED
AND WELLS AS SET
ENLARGEMENT IF THE
V3. 2
(907) 243.7893
KEN JOHNSON
KEN'S COMPANY
WATER WELL DRILLING
PUMP SALES & SERVICE
April 5, 1980
Jerry Bauer
Lot 4A BLK 2 Boyle Subdivision
Wagner Road
Anchorage# Alaska
3163 LINDEN DRIVE
ANCHORAGE, ALASKA 99502
MVNICIPAERY CF, ANCI Z' Z
OEPt. OF 1 ..:1_CiION
EPNIRONME IIAE 'r..•
reAy q 1980
R�.cEiv E�
WATER WELL LOG
0 FT.
to
18Ft.
Brown Silt
18 FT.
to
27FT.
Gravel and Gray Silt
27 FT.
to
30FT.
Water Bearing Sand and Gravel
30 Ft.
to
38FT.
Fine dirty sand water bearing
38 Ft.
to
75FT.
Cement Gravel
75FT•
Clean medium gravel and course
sand water bearing
Static. . . 20FT
Test Bail 15 GVM
Drawdown 20FT ( Good Recovery)
Very clean water
Total Depth 75 Ft.
MVNICIPAERY CF, ANCI Z' Z
OEPt. OF 1 ..:1_CiION
EPNIRONME IIAE 'r..•
reAy q 1980
R�.cEiv E�
I M*VtIV SL:PTIC, SYMM ty^v 1 •,1980 OESIGN; R.' ,ess6t
A N..T
,o 'mul. To PRoa[RTT LiHE
T 4A
t
CLEM CLOCK
4IV •"T' ! 6oYLe 5v80IVISIarI
IS' i 391
1 Fi&l T' PLooR
_ _
6�r ..� z I I
,! SEs H4��[ -
U.1 I — IooO ca,� : -- �•�. 110 165
' 5EPTtY
Awe �y t _
•
•: .:rte _.. _ _ •
3 r fi-2 -
`�,JETS`--bVILT OF ,SEPTIC 5-1'5 TEM
ESTim ATE& FLOty 3 eE0EOOM a 50 . SPD
GRAVEL TRENCH BOTTOM VLTIMATE PERM6ADILITy = 1\23 GPD
51LT- SV5GIZADP- PeRMGABILITY ..=.'•2.4 GPD .`.
TkGncN. - Bo'I'TOM RREA--RE@v�REp = 3b6 •F�f z .
"I -j-7-41 of 31 -WIDE- Tf-f:NCV ff-Q'D)
EoF -4%
NOTES �,,«..AAs�
�.
` r ,.• �-, '•..9 001
PLACE A! PERF . , PVC ToPRoVloc i* 4SL
I, • k,0
.N\. \ N
F", GAt, VE.L BELOW 111 VC )LT.
2. MUIIMVNt ItrICRT OF r-PAVEL
� 3 TfUlIcN BOTTOM llfc vE WFITE,s;
"'I• -ABLE; J3 4 FEET • �y .....
3, TOP OF SAND FILL SNALL BE Le i L 'To t p,2 _
6&Mt/t OF._GP-AvcL TRENC115. SHALL. BE LjFVZI� To +o.z'
r`aAoVND SlrPTIC sy
FOR reRRy BAVea ReS.
Z OF 2
1' TO ZiI GRAVEL PLACED
' T 3'WIDE- .SILT CAP.OVEA. ShNO FILL 12"-.
;THICK� SHAPE .FOR, ORAIIlRGE,
MIN:'Top301L, 2",. Dow..SM sTYRoFoArR ;_
VEGErA7E WiTN 4" PEAF.,.PVC PLPLET
yPJFE
'1 PROVIDE 8 GRAVEL dELo
^oacn
SANb�t FILL`
r
To t✓l•'� _ OA4 n
r�A••MUAT
I_
��:: SILT \
-. �
W. {
-' SuBGRADE I —W:T.
CROSS LN.;: A A:,.
11
,SE _Tl
WT. VARIES
INtWCr1T
4'
s
42'.I
-To
t 1
._ IuSULATION LIMITS
.24,X46' AREA—
'
`La Dot✓ SM
7
�oF
_.._
FIX
t:q
dMA"
1 LEVEL .ta
1
r
140
1
I
`
I
�F..O...gt.�
r�F;• .
rte;„
r ..r3TtI s;':a
1
,.........�f
00.... y.._
1.
�J*•.....�......-!... r
K`
.William A. Roberts
No. 4464 - E
L— — - — -24r
�✓1a��eoatml'
.PLAN VIEW
* •e
iQ...,
471
RSM CONSULTANTS, INC. 5024 GOXOOVA . NOX 1047 . ANG.IORAGf. ALASKA 54502—•moi .N, 107.211-04a3 . iLX. 090.4 Salo
f NG�nf
. i.
.'JiVaVo.VOR!
October 11, 1977 RSM No. 751241
Patricia Bond
1200 W. Dimond B1vd.,.Space 1460
Anchorage, Alaska 99502
Subject: Soil Investigation for Sanitary Sewer System, Lot 4A, Block 2,
Boyle Subdivision, Anchorage, Alaska _
Dear Ms. Bond:
At your request of September 29, 1977, we conducted a subsurface soils
investigation at the proposed location of the sanitary sewer system on
the subject lot. The investigation complied with those procedures
required by the Municipality of Anchorage, Department of Health and
Environmental Protection.
This investigation, which was accomplished on October 4, 1977, consisted
of a test hole drilled to a depth of 20 feet below the existing ground
surface. The test hole was sited according to your instructions and its
location is shown in attached Drawing A-01. Drilling was accomplished
with a rotary drill rig using continuous flight solid -stem auger with .
an outside diameter of 6 inches. A sample was taken at the depth shown
on the soils log in Drawing A-01. The sample will be held in storage at
our lab for approximately six months. In addition, all material brought
to the surface by the augers was continuously monitored by an experienced
engineering geologist.
The topography at the drilling site is generally horizontal. At the time
of the investigation the site had original vegetation consisting of
spruce trees. The top of the test hole was located at original ground
surface.
The soils encountered in the bore hole are shown in the test hole log in
Drawing A-01. The symbols used in Drawing A-01 are explained in Drawings
B-01 and B-02. This log displays specific conditions encountered at the
test location. However, subsurface conditions may vary in other parts
of the lot without any apparent surficial evidence of the change.
Groundwater was not encountered. Bedrock was not encountered. At the
time the hole was drilled seasonal frost was not present. Permafrost
was not encountered.
A percolation teat was performed within the bore hole at the depth shown
in the attached Table 1. All depths were measured from the to_ of the
hole. The data in Table 1 show average infiltration from the depths
indicated to the bottom of the hole. The measured percolation rate was
22.81 minutes per inch.
wNCNOw AGI F^IN.wNKS 2UNf AU VALO[i V1A31LL^
n
October'll, 1977
Patricia Bond
Page -2-
n
We appreciate this opportunity to be of service to you. Please contact
us if you have any questions concerning this letter or if we can be of
additional service.
Very truly yours,
R & M CONSULTANTS, INC.
Jeffrey 111. Ayres
Staff G_olcgist
gld
Jim McCaslin Brown,
Head, Earth Science Department
Attachments: Drawings A-01, B-01, B-02, Table 1
-.iz J' .� Y�l-C � Y.7_`��~V'!i [ +MVV. .�i�f`,.Y' ♦y,ii . Y„ ,�...� 4�.r+ R.�c wr. f� N. :w:.v�r Fnt,. � cv.
n
PERCOLATION TEST RSM No. 751241
Patricia Bond
10/5/77
2.63 Inches Total Drop
22.81 Minutes Per Inch
Elapsed
Time
Time
Inches
Droo In Inches
2:00
0
6.25
0.0
2:01
1
8.56
0.31
2:02
2
8.75
0.19
2:03
3
8.88
0.13
2:04
4
8.88
0.00
2:05
5
9.00
0.13
2:06
6
9.06
0.06
2:07
7
9.13
0.06
2:08
8
9.19
0.06
2:09
9
9.25
0.06
2:10
10
9.25
0.00
2:15
15
9.5
0.25
2:20
20
9.75
0.25
2:25
25
9.94
0.19
^ 2:30
30 =
10.13
0.19
2:40
40
10.44
0.31
2:50
50
10.63
0.19
3:00
60'
10.88
0.25
2.63 Inches Total Drop
22.81 Minutes Per Inch
Note: Alaska Water and Wastewater Consultants, Inc. shag be paid $200.00 at, .
or prior, to, closing for the engineering services provided.
5.' STATEMENT OF. INSPECTION BY ENGINEER r' ::..:. > ,; ` •`
As certified by my seal affixed hereto and as of the validation date shown below, l verify that my
Investigation of this Health Authority Approval application shows that the on-site water supply and/or
wastewater disposal system is safe, functional and adequate for the number of bedrooms and type of
structure Indicated herein: I further,verify that based on the Information obtained from the Municipality of r
Anchorage files'and from my.investigation and inspection; the ori - site water supplyand/or wastewater,
disposal system Is In compliance with all Municipal a State codes, ordinances, and regulations in effect
on the date of this inspection. ,
Name of Firm tALASKA'W ; RCONSULTANTS.,�,.INC. Phone_(907) 337-6179
Addres§ 6901 DEBA NC ORAGE. ALASKA, 995W
Engmeer's;Signature Date 5 is'co
In conducting this evaluation; AWWC, l ted to provide a thorough, consdenntlous engineering analysis of the
�tem ln'accordance wittiADEC_and _ D_ S Guidelroes & Regt! a ions The reposed results described the
omrance o/ the system under the condrtrvns encountered et fhe time of the tes4 and sepanition distances '
measured to ieadiy /dentrfiable features. The.operationaf I of all wells and septic systems depend; ,
on the local soils condition: ground water levels that may Buctuate'during the year, and the water
usage 6f the family being served by Bre system. '7hese conditions are outside the control of o�OF �pO
the evaluator of the system. Satisfactory test rssufta cb notran
guatee future peAormance P lam., • . • QO
of the system, nor do they guarantee that there are no hidden detects or encroachments.
AWWC,'/nE can therefore not protide any warranty for future estimate of how long the p�
tem will continue to meet the operational requirements of the ADEC or MOA DHHS Q ° r
system opera . re4. _ .. _ .. Q : �
The content of this report is for the sole benefit of the owner listed above. Any Q
reliance upon or use o/ this report by any other person or party is not authorized, : . •
nor will It comer any legal fight whatsoever
Q7953
6. DHHS SIGNATURE 4P �Fa
Approved for bedrooms 44��40000�ne\�coo
Disapproved
Conditional approval for bedrooms, with the foliowmg stipulations
Additional Comments
it
By:Date
The Municipality of Anchorage Department of Health and Human Services (DHHS) Issues Health Authority
Approval Certificates based only upon the representations given in paragraph 5 above by an independent
professional engineer registered in the State of Alaska. The DHHS does this as a courtesy to purchasers of
homes and their lending Institutions in order to satisfy certain federal and state requirements. Employees of
DHHS do not conduct Inspections or analyze data before a certificate is Issued. The Municipality of
Anchorage is not responsible for errors or omissions in the professional engineer's work.
72-M (Rev. 7181) Back MOA #21 Computer Version
?%ECEIVED
Municipality of Anchorage MAY 15
. .. DEPARTMENT OF HEALTH & HUMAN SERVICES
Environmental Servkes Division muNICIPALITY Of A
825 *V Street. Rm 502 Anchorage. Alaske 99501 (907) 343-4744,mENTAL SFRVI
Health Authority Approval Checklist
Legal Description: BOYLE S/D: LOT 4A. BLOCK 2 Parcel I.D.: 015-282-21
A. WELL DATA
Welt Type PRIVATE H A, B, or C, attach ADEC letter. ADEC water system number N/A
Log prem (Y/N) YES Date completed 4/5/80
Total depth
Sanitary seal (Y/N)
Date of test
Static water level
Well production
Cased to 75' Casing height (above ground) 1.4'
FROM WELL LOG
WATER SAMPLE RESULTS:
4/5/1980
15 g.p.m.
Wires properly protected (Y/N) YES
AT INSPECTION
3/29/2000
6.8 g.p.m.
Coulbrm 0 Nitrate 3.4 mo/L Other bacteria 0
Date of sample: 4/19/2000 Collected by: A.W.W.C.. INC.
B. SEPTIC/HOLDING TANK DATA
Date installed 11/15/80 Tank stns 1000 Number of Compartments 2 Cleanouts (Y/N) YES
Foundation cleanout (Y/N) YES Depression (Y/N) NO High water alarm (Y/N) N/A
Date of Pumping 3/29/2000 Pumper A+ HOME SERVICES
C. ABSORPTION FIELD DATA
*SEE ATTACHED REPORT
Data installed 11/15/80 Soil rating (g.p.dJft2 or t 2/bdrr v 330 System type BED/TRENCHES
Length 64' Width 42' Gravel thlclawn below pipe 8" Total depth 2' — 2.66'
Effective absorption area 2688 SO FT MonitDM9 Tube present (Y/N) YES Depression over field (Y/N) N_
Data of adequacy test 3/29/2000 Results (Pass/Fall) PASS For 3 Bedrooms
Fluid depth in absorption field before test (tn.r 3.5 immediately after 117.8 gal. water added (In.): 8.5
Fluid depth 0 (ins) Minutes later. 983 Absorption rate = *450/0.357 GPM
Pero)dde treatment (past 12 months) (Y/N) NONE KNOWN if yes, give date -----
n-= MW. =r CWVtdW VWWW
D. LIFT STATION
Date installed Size
Mantrola/Access
High water alarm
level at` "Pump ofr level ar
'Datum
E. SEPARATION DISTANCES
SEPARATION DISTANCES FROM WELL ON LOT TO:
Sepddholding tank on lot 96'+/— (WAIVER 5/17/88) On adjacent kits 100'+
Absorption field on lot 100'+ On adjacent lots 100'+
Public sewer main N/A Public sewer manhole/cleanout N/A
Sewedsepdc service line 25'+ Lift station N/A
SEPARATION DISTANCES FROM SEPTICIHOLDING TANK ON LOT TO:
Foundation 5'+ Property line 5'+ Absorption field 5'+
Water maintservice line 10'+ Surface water/dralnege 100'+ Wells on adjacent lots 100'+
SEPARATION DISTANCES FROM ABSORPTION FIELD ON LOT TO:
Property line 10'+ Building foundation 10'+ Water maintservice line 10'+
Surface water 1000+ Driveway, parking/vehide storage area 10'+
Curtain drain NONE KNOWN Wells on a
"1k„ PFJ4rNirderl-104 PAPWIq
F. ENGINEER'S
I certify that 1 I
"
Engineer's Naniq r — JEFFREY A.
HAA Fee S 3 m , 0 0)
Date of Payment
Receipt Number 37 C 6`50
M42e (Rsv. 3Nar CMMUW V081M
kapectlons and review
ams are in conformance
Is date.
Waiver Fee S
Date of Payment
Receipt Number
ALASKA WATER & WASTEWATER
CONSULTANTS, INC.
April 27, 2000
Scott Forrest
12101 Wagner Rd.
Anchorage, Alaska 99516
Ref: Boyle S/D Lot 4A Block 2
Well and Septic Adequacy Test
Dear Mr. Forrest,
Per your request, we performed an evaluation of the water well and septic system which serves
the subject property. The results of our investigation are summarized below.
WF .t[ TF
The well was tested on March 29, 2000. Production was 562 gallons of water over a period of 83
minutes. This is equivalent to 6.8 gpm, which is more than adequate for a 3 bedroom house. The
initial static water level was 33 ft, and the stabilized drawdown was 19 ft. Other conditions for
the Health Authority Approval (HAA) from the Municipality of Anchorage (MOA), i.e. casing
height, sanitary seal, and wires conduited, were also met. The well is located 96 ft from the septic
tank on the property, rather than the required 100 ft. A waiver was obtained for this
encroachment in 1988. The water was tested, and results were 3.40 mg/l nitrates (maximum is 10
mg/1) and no bacteria. Therefore, the well meets all requirements for the HAA.
SEPTIC SYSTEM TEST
As per MOA records, the septic system consists of a 1000 gal tank and an elevated bed drainfield,
both installed in November 1980. The bed consists of 4 individual trenches with 8 inches of
gravel below the distribution pipes. Two monitoring tubes were installed in January, 1994, which
enables observation of 2 of the trenches. It is impossible to detect fluid levels in the other two
trenches. At the time of our inspection, one of the trenches was submerged, with 8.75 inches of
water in the monitoring tube (MT). The MT in the other trench had 3.75 inches of water in it. A
total of 109.8 gallons of water was added to the unsubmerged MT which rose the liquid level 5
inches (22 gallons per inch). Absorption was monitored in this MT 5.5 hours later and the level
had dropped 7.75 inches, indicating the bed had absorbed at least 110 gals. This indicates
absorption of greater than 0.312 gpm, which meets the requirement for a 3 bedroom house.
Our evaluation confirms that one of the trenches has failed and one is still operable. The
condition of the other two trenches is unknown, due to lack ora monitoring tube.
6901 Debarr Road, Suite 2B — Anchorage. AK 99504 — Ph: (907)337-6179 — Fax: (907)338-3246
As per your discussions with the Department of Health and Human Services Onsite Wastewater
Division personnel, we may submit these results to the city and request a HAA. Please notify us
when you are ready to proceed with the HAA application.
Thank you for this opportunity to provide engineering services for your well and septic system. If
you have any questions about this report, please contact me at 337-6179.
Sincerely,
cwe
.E., M.S.
6901 Debarr Road, Suite 2B — Anchorage, AK 99504 — Ph: (907)337-6179 — Fax: (907)338-3246
C4424-00 17:40 FROM -CTE ENVIRONKfITAL 5615301 T-489 P.02/03 F-764
CT&E Environmental Services Inc.
CT&EReitt
100i647001
Client PON
Client Name
AK Water & Wastewater Consultants Inc.
Printed Date/time
04242000 IS. -36
ProjectName/N
Boyle SID LoY4ABk2
Collected Date/time
04/192000 11:00
Client Sample ID
Boyle SID Lot 4A Bk 2
Received Datt/Time
04/192000 11:40
Matrix
Drinking Water
Technical Director
Stephen C. Ede
By
Released
/�
-eow
PWSIOrdered
PWSID
0
Sample Remarks
Allowable Prep Anatysie
Parameter Results POL units Method Limits Daze Date init
LAYERS DEPT
Nitrate -N
MICRO LAR
3.70 Moo ag/L EPA 300.0
010)
04/19/00 SCL
Tozat Coliform 0 eol/t00mL SMIS 92226 O4/19/00 RAP
• 3-51
MUNICIPALITY OF ANCHORAGE
• DEPARTMENT OF HEALTH & HUMAN SERVICES
Division of Environmental Services
On -Site Services Section
P.O. Box 196650 Anchorage, Alaska 99519-6650
343-4744
CERTIFICATE OF HEALTH AUTHORITY
APPROVAL FOR A SINGLE FAMILY DWELLING
Parcell.D.# Q15—a9,a-Q1 HAA# rnQ�
1. GENERAL INFORMATION
art
Complete legal description Lot 4A: RPor,k 2; Bayfo 4uhdly/A,inn
Location (site address or directions) 12101 Wagnea Street
Anrhnnag0 AK
Property owner Patn,f.ch Phe&n Day phone 345-4925
Mailing address 12101 Wagner Sttee.t Anchorage AK 99516
Lending agency Day phone
Mailing address
Agent U -sal SIMPSON CO. REALTORS Day phone 345-6644
Address 12350 TnrInA Y lijej! Anrhn_amcIg, AK 99515
Unless otherwise requested, HAA will be held for pickup.
2. NUMBER OF BEDROOMS: 3 �v
3. • TYPE OF WATER SUPPLY:
Individual well XXX
Community well
Public water
NOTE: If community well system, provide written confirmation from State ADEC attest -
Ing to the legality and status of system.
4. TYPE OF WASTEWATER DISPOSAL:
Individual on-site XXX
Holding tank
Community on-site
Public sewer
NOTE: If community wastewater system, provide written confirmation from State ADEC
attesting to the legality and status of system.
T2-075(Rw.1/91l front MOA471
5. STATEMENT OF INSPECTION BY ENGINEER
As certified by my seal affixed hereto and as of the validation date shown below, I verify that my
Investigation of this Health Authority Approval application shows that the on-site water supply
and/or wastewater disposal system is safe, functional and adequate forthe number of bedrooms
and type of structure Indicated herein. I further verify that based on the information obtained from
the Municipality of Anchorage files and from my invest!gation and Inspection, the on-site water
supply and/or wastewater disposal system is in compliance with all Municipal and State codes,
ordinances, and regulations in effect on thgdateof inspection.
Name of Firm Phone l'9�-2y7 9
Address 5 6 5 ENGINEERING /
Engineer's sign9V
£i,cr, Alaska 995 Date Z y
6. DHHS SIGNATURE gg
Approved for __2— bedrooms.
Disapproved.
By:
Conditional approval for bedrooms, with the following stipulations:
JUonL
Additional Comments
�a -
1n , Date / 2UZ�t4Z
•
The Municipality of Anchorage Department of Health and Human Services (DHHS) issues Health Authority
Approval Certificates based only upon the representations given in paragraph 5 above by an independent
professional engineer registered in the State of Alaska. The DHHS does this as a courtesy to purchasers of homes
and their lending institutions In order to satisfy certain federal and state requirements. Employees of DHHS do not
conduct inspections or analyze data before a certificate is issued. The Municipality of Anchorage is not
responsible for errors or omissions in the professional engineer's work.
724M(a«.1.11) B. k raym .
Municipality of Anchorage
Department of Health and Human Services
HEALTH AUTHORITY APPROVAL CHECKLIST
Legal Description: Lor 4A OL6eK 2 goYt_ES/DParcel I.D.
A. Well Data
Well type P?Iva TE_ If A, B, or C, attach ADEC letter. ADEC water system number N/A
Log present&) `SEC Date completed ��S�BV Driller KE/J S Com' II Jr
Total depth 25" Cased to ?r Casing height 1 r+
Sanitary sea (ON) '?F_ S Wires properly protected (ON) YE51S
FROM WELL LOG AT INSPECTION MUNtGP�� � f),tA( Ot�tStON
Date of test �%5�80 /�9�y¢ EtNteo�^Erzt
r �� 13 1994
Static water level ZO • Z4 - ,
Well flow lSa g.p.m. • �/ g.p.m. ID �D
Pump levelt UK PUMP NO%
SEPARATION DISTANCES FROM WELL TO:
Septic1lWdiAq tank on lot On adjacent lots /UU "'f'
r (t
Absorption field on lot _ _ � � S � ; On adjacent lots /00
i
Public sewer main / n S 4 Public sewer manhole/cleanout
Sewer service line ZS ek Petroleum tank j&IONLE KG _bw N
WATER SAMPLE RESULTS:
Ing
Coliform ��/o�' Nitrate Z.%�y.� Other bacteria /<°
Date of sample: Collected by: S5* S EiCJC,/ivLrfJt'Jiyt;
B. SEPTICARX0111416-TANK DATA
Date installed 1 f 11494) � Tank size /000 GA(_ ' 7 Compartments Z
Cleanouts&) 5�6_i Foundation cleanout((Y ) TE< Depression (YQ U0
High water alarm V6 T Z: Alarm tested (YIN) A ,1A
Date of pumping 104- Pumper _ /qt . R0/4 5 SEIZu/LAS
SEPARATION DISTANCES FROM SEPTICA40I•�TANK TO:
Well(s) on lot /60 On adjacent lots /0 C. �f Foundation
To property line /(> r*- Absorption fielWater main/service line It) �
Surface water/drainage
-�<- rEK 1 k)__ye-cT1,e*J
nazs (3?93)•Fmt CONTINUED ON BACK PAGE
C.LIFTSTATION NONCE P1t(E56_1T
Date installed
Size in gallons
Vent (Y/N)
High water alarm level
Manufacturer
Manhole/Access (Y/N)
'Pump on' level at
Meets MOA electrical codes (Y/N)
SEPARATION DISTANCE
Well on
D. ABSORPTION FIELD DATA
STATION TO:
at
adjacent lots Surface water
�c- ra' � Ezc'v�tTED
Date installed%/f( J'6Soil rating (GPD/Ft2) S30 C System type
Length h4 Width 42' Gravel thickness 0,64 Totai depth Z'— Z'"' rt—
Total absorption area Zo�; Cleanout presentY�i 1) �%ES Depression over field (YJQ N�
Date of adequacy test Resul pas fail) /011. ' for KE LS)
Bedrooms
Water level in absorption field before test C)I/ K) After test /O
Peroxide treatment (past 12 months) (YM) /VIVE K92L fJ AJ If yes, give date
SEPARATION DISTANCE FROM ABSORPTION FIELD TO:
/, �
Well on lot H S On adjacent lots Ice)f f Property tine d 1
To building foundation —To existing or abandoned system on lot
i
On adjacent tots /0(�) Cutbank A)OA,6 P206I/TWatermain/serviceline !D
Surface water �(7 J 't Driveway, parking/vehicle storage area
S.1
Curtain drain .(IO.UE fit.) )AJ ->t-Pe/zIIUS/��G/%orV 9L�02
77
E. ENGINEER'S CERTIFICATION
1 certify that I have checked, verified, or conformed
Signature
Engineer's Name 17034 Eagle
Date
Z /'1oN/7a1u1_JG TUrSCS 11JST.9C4_E0 /A-'
,aFP SY T✓E&D 6-9 oN //&/5 Pt6SVJCe'
OF /PSUL 770/J WAS /,Xr67)-
UA and HAA guidelines in effect on the date of this inspection.
c al }
f' n • 1
No. 204
{r
f ..
14374 r
HAA Fee $ 7L7✓yu
Date of Payment 1 �✓ ���
Receipt Number. oZS 51 C�
72-026 (393)' Back
Waiver Fee $
Date of Payment
Receipt Number
N.kCOMMERCIAL TESTING & ENGINEERING CO.
ENVIRONMENTAL LABORATORY SERVICES
S.hC[ Ip[
Chemlab Ref.# :93.6935-3
Client Sample ID :L4A BLK2 BOYLE S/D
Matrix :WATER
Client Name :S & S ENGINEERING
Ordered By :RAY
Project Name
Project#
PWSID :213483
e Remarks:
Parameter
Nitrate --N
REPORT of ANALYSIS 5633 B STREET
ANCHORAGE, AK 99518
TEL: (907) 562.2343
FAX: (907) 561.5301
RUSH Order :74552
Report Completed :01/04/94
Collected :12/29/93 @ 12:15 hrs.
Received :12/30/93 @ 14:35 hrs.
Technical or: TEPj C.��
Released aced BBy
SAPll'" WLJ.G(;1tU BY: 5.5.
QC Allowable Ext. Anal
Results Qual Units Method Limits Date Date Init
2.73 mg/L EPA 353.2/300.0 10 01/03 LLH
-----------------------------------------
* See Special Instructions Above UA = Unavailable
** See Sample Remarks Above NA = Not Analyzed
U = Undetected, Reported value is the practical quantification limit. LT = Less Than
D = Secondary dilution. GT = Greater Than
��N SGS Member of the SGS Group (Societe Generale de Surveillance)
ENVIRONMENTAL SERVICES IN ALASKA, COLORADO, UTAH, ILLINOIS, OHIO, MARYLAND, WEST VIRGINIA, NEW JERSEY, SOUTH CAROLINA
�l Y,l ark
MUNICIPALITY OF ANCHORAGE
DEPARTMENT OF HEALTH & HUMAN SERVICES V
DIVISION OF ENVIRONMENTAL SERVICES ,f
CERTIFICATE OF INSPECTION FOR HEALTH AUTHORITY APPROVAL N 8!2 -D]a 9
OF ON-SITE SEWER AND WATER FACILITY
264-4744 n LJ z;� TO'0
Application Date A ^I ZL r ( 9 P -r
1. GENERAL INFORMATION (MUST BE COMPLETED PRIOR TO SUBMITTAL)
(a) Legal Description (include lot, block, subdivision, section, township, range)
1.07 xA a IC :Z 13 aN. 2 31t'/
Location (address or directions)
(b) Property Owner
(c)
Telephone: Home LVe- 1191 b Business
Mailing Address rk1a I
A w
k
Lending Institution �i-
R aI3Rr
Mailing Address
(d) Real Estate Company and Agent
Telephone
Address
Telephone
(e) Mail the HAA to the following address: or: Check here If hold for pickup.
List contact person and day phonce� number below.
Ate• 31 IL/.L
2. TYPE OF RESIDENCE
Single -Family 1�
Number of Bedrooms
3. WATER SUPPLY
Individual Wel Community ❑ Public ❑
Note: If community well system, must have written confirmation from the State Department of Environmental Conservation
attesting to the legality and status.
4. SEWAGE DISPOSAL
Onsite Public ❑ Community ❑ Holding Tank ❑
Note: If community well system, must have written confirmation from the State Department of Environmental Conservation
attesting to the legality and status.
Page 1 of 2
71-025 $A" 8'861 From
4398 W9,9 Nm stow Z to Z abed
•iliom s, aau16ua
!euo!ssa)oid a4i ui suo!ssiwo io siaia iol alq!suodsai lou sl a6eio4ouy io pped!olunpy a41 •panss! s! aleo!i!liao a aioiaq
elep azAleue io suo!loadsui lonpuoo lou op SHHO to saaAoldw3 sluawaiinbai alels pue leiapal uieliao /llsiles of iapio
u! suo!inigsui 6u!pual iia41 pue sawo4lo siasegoind of Asalinoo a se s141 saop SHHO 941 •e4sely)o alelS a4i u1 paials168i
iaaui6ua !euoissaiad luepuadapu! ue Aq anoge S 4dekeied ui uaA!6 suoileiuesaidai 841 uodn Aluo paseq saleoggiao
!enoiddy AjtA41ny 41leaH sanss! (SHHO) sao!AiaS uewnH pue 41IeaH to luawpeda(] a6eio4ouy to /4!lediolunyr a41
NOI1f1V0
G9—p7/—J" "p7/J"
Ienoiddy !euog!puo0 )o swial
leuo111Puo(] Panaddesi0 panaddy
ale(], Aq swoaipaq io) panaddy
IVAOHddV SHHO
1L61 'SZ 3KIlf o ��
leas s,iaaw6u
•i- p
- ti~
ale(]
C� �Q ssaippV
euo4dalal � wnj io aweN
uoiloadsu! sN) )o alep a4:
uo loa8a u! suo!leln6ai pue'saoueu!pio'sapoo alelS Pue led!o!unyy Ile 41!m soue!ldwoo uf s! walsAs !esodsip ialemalsem
ioipue Alddns ialem alis-uo a41 'Uoiloadsui pue uo!1e6!lsanu! Aw woil pue saps a6eio4ouy to Apledioiunyi a41 woil
pau!elgo uollewio)ui 941 uo paseq le41 AivaA iaglinl I •uiaia4 paleo!pu! amlonils )o odAl pue swooipaq to iagwnu a43 iol
alenbape pue leuoilouni'ales sl walsAs lesodsip ialemalsem io/pue Aldd ns ialem el!s-uo a4i le41 smo4s lenoiddy Al!ioglny
41leaH s!41 to uo1le61lsanu! Aw Imp AivaA I'molaq UMOLIS alep uo!lep!IeA a41 Jo se pue olaia4 pax!iie leas Aw Aq paipliao sy
9
NOIIVWUOdNI ONV VIVO'H0HV3S 3114'S1S31'SNO1103dSN1 ONIOIAOHd WHId ONIIl33NION3 'S
rr
n
dICIPALITY OF ANCHORAGE (MOA)
r`(Ct S010HEALTH AUTHORITY APPROVAL (HAA)
CHECKLIS2F� �UARY1984.
Legal Description AOT VA Sk g Bay e-
`L�`�7�ax/ e 3 Iv
A. WELL DATA
Well Classification' Kis If A, B, C. D.E.C. Approved (Y/N) L/A
Well Log Present (Y/N) �� Date Completed y/y��0 - Yield IS P?M1
Total Depth q7•s Cased to Depth of Grouting NONE
Static Water Level ' /9 Pump Set At ' SoTTOH
r
Casing Height Above Ground _ ii Sanitary Seal on Casing (Y/N)
Electrical Wiring in Conduit (Y/N') _ Depression Around Wellhead (Y/N) IN/
Separation Distances from Well:
To Septic/Holding Tank on Lot Q�o / ; On Adjoining Lots Nb l lE
To Nearest Edge of Absorption Field on Lot >10�0 ; On Adjoining Lots hl O Wim•
To Nearest Public Sewer Line NONE To Nearest Public Sewer
Cleanout/Manhole H 0 N L To Nearest Sewer Service Line on Lot 1 �O
Water Sample Collected by Y S ; Date �/lILOA4
Water Sample Test Results
Comments
B. SEPTIC/HOLDING TANK DATA
Date Installed 1160 Size lurk No. of Compartments Tfy/D
Standpipes (Y/N) ONE Air -tight Caps (Y/N) Foundation Cleanoo �t ( /N)
IV._
Depression over Tank (Y/N) �Date Last Pumped y„2Bt e,*t
Pumping/Maintenance Contract on File (Y/N) A04 ; for W
Holding Tank High -Water Alarm (Y/N) _y.4 Temporary Holding Tank Permit (Y/N) MIA
Separation Distances from Septic/Holding Tank:
To Water -Supply Well -To Building Foundation �g
To Property Line Z L To Disposal Field In f
To Water Main/Service Line 2 / y To Stream, Pond, Lake, or Major Drainage
Course N O N E
Comments
Page 1 of 2
72 -OM IRr 8 MI Front
C. ABSORPTION FIELD DATA
Soils Rating in Absorption Strata 33o Type of System Design' 'gyp KO v
Date Installed p Length of Field V Y
Width of F' dk �Z. Depth of Field ' y S414
Q N
Gravel Bed Thickness O
Square Feet of Absorption Area Standpipes Present (Y/N) -IV
Depression over Field. (Y/N) _
Results of Last,Adequacy Test
Separation Distance from Absorption Field
Date of Last Adequacy Test Yl20 Ai B
To Water -Supply Well MO f To Property Line - /0
To Building Foundation 30 t • To Existing or Abandoned System on
Lot N O N t : On Adjoining Lots • N O NL
To Water Main/Service Line % To Cutbank (if present) N ON1L0'
To Stream/Pond/take/or Major Drainage Course N o N a
To Driveway, Parking Area, or Vehicle Storage Area O f
Comments _
D. LIFT STATION
Date Installed .
Size in Gallons —
"Pump On" Level at
High Water Alarm Level at
Tested for
Electrical Codes (Y/N)
Comments
— Dimensions —
Manhole/Access (Y/N)
_ "Pump Off' Level at
Check Permitted Bedroom Rating Against HAA Request "
— Vent(Y/N)
Pumping Cycles during Adequacy Test. Meets MOA
Icertify that Ihave checked, verifie or conformed to all MOA and HAA guidelines in effect on the date of this inspection.
Signed Date
Date'Zy"8a
Company MOA No.
Receipt No.
Date of Payment
Amount: $
v
Page 2 of 2
77-078 (Bev 8'881 Pack
Engineer's Seal
OF Af,
,
tx, VE iS. l9rl
J:'i
Engineer's Seal
03
40 �� W )G^3RUrj1Dw poEo 2 A CHORAGE, ALASKA 99501
CONSULTING ENGINEER TELEPHONE: 19071 2 79-3 91 6
SEPTIC.SYSTEM ADEQUACY TEST
� OFA �lk
LEGAL: Lot 4A, Block 2, Boyle �T,•• c t+
LOCATION: 12101. Wagner P,* 4S TM
OWNER: Jerry & Gloria Bauer j••:••"' •:'•
z
7.0 . UNE 2S,97E :.:n
RESIDENCE: Single Family, Three Bedrooms 4`
WELL: On Site Single Family 4
+t`14s��� 5•`
SEPTIC SYSTEM: FROM MUNICIPAL RECORDS:
TANK: Greer Steel, 1000 Gal Two comp.
ABSORPTION SYSTEM: Bed, Mound
ABSORPTION AREA: 2688 sq. ft.
SOIL RATING: 330
INSTALLATION DATE: 1980
DATE OF LAST PUMPING: April 15, 1988 Issac's
DATE OF TEST: April 20, 1988
TEST PROCEDURE: System was inspected and measured. Tank was
found with 1.5 feet of cover and a liquid depth.of 49 inches.
There were no monitor tubes installed in mound...An observation
well was dug at the periphery of the mound. Hole was 5 feet deep
and extended two feet into the sand filtering layer. Water
showed at the bottom of the.hole. The sand was clean with no
color or odor to indicate anaerobic conditions.
370 gallon of clean water were added to the tank: At this point
water back up into the tank. Level in tank rose 13 inches.
Infiltration were monitored for 60 minutes. During the first 15
the level in the tank dropped 7 inches. After 60 minutes the
level had dropped 10 inches. After 15 hours the tank level was
49 inches. The residence was occupied during this period with no
restrictions on water use.
TEST RESULT:. This system meets the.code requirements of
the Health and Social Services Department of the Municipality of
Anchorage.
NOTE The operational life of all septic systems depends on the
local soil conditions, groundwater 'levels that may fluctuate
during the year, and the water usage of the family being served
by the system. These conditions are outside the control of the
evaluator of this septic system. We can therefore not give any
estimate of how.long this system will function satisfactory for
current or future occupants.
Municipality of Anchorage
Department of Health and Human Services
Tom Fink 825 "L" Street
Mayor P.O. Box 196650 Anchorage, Alaska 99519-6650
May 17, 1988
Tobben Spurkland, P.E.
203 West 15th Avenue "C" Suite 203
Anchorage, Alaska 99501
Subject: Waiver Request For Lot 4A Block 2 Boyle Subdivision
Waiver Request Number WR88-019
Dear Mr. Spurkland:
Your request for waiver of the required 100 foot separation of
a septic tank to a private well is approved. The approved
separation is 96.44 feet.
Reasons for granting this approval are: First, the well is
uphill from the septic tank. Second, you have verified water
tight couplings on the septic tank. Thirds there are adequate
points supporting this waiver of separation distance by the
A.D.E.C. waiver guideline procedure.
This waiver applies to the existing well to septic tank
separation only. Any future upgrade to either will require all
separations be met or another approval from this department.
Sincerely,
Daniel J. Roth
Civil Engineer
On -Site Services
cc: Gus Andress, P.E., Manager
On -Site Services/Water Quality Programs
III
P,
V0 t A �NP�-,nmL,AA 1))9 PAA
CONSULTING ENGINEER
Municipality of Anchorage
Division of Environmental Health
Department of Health and Social Services
820 L Street
Anchorage, Alaska 99501
203 W. 151h AVE "C SUITE 203
ANCHORAGE. ALASKA 99501
TELEPHONE: (907) 279-3916
MLMPAUW OF ANOCPAW
Deur. OF HEALTH i
PMRONMENfAL PRoTwnm
MEMO, 1988
Subject: REQUEST FOR WAIVER OF SEPARATION DISTANCES FOR
PRIVATE WELL TO SEPTIC TANK
LOT 4A, BLOCK 2, BOYLE S/D
JERRY BAUER
Gentlemen;
We are submitting a request for waivers from the separation
distances stated in Title 18, Alaska Administrative Code,
Chapter 80.020.
During an Health Authority Inspection on April 20, 1988 is was
discovered that the distance between the tank and the septic
tank was 96.44 feet, 3.5 feet less than the required 100 ft.
The well is located up hill from the septic system. The house
is situated between the well and the tank. The well log
indicates water at 27 feet, however, pounding surface water was
in evidence around the residence as is common in Boyle.
The design of the septic system was based on ground water at 1
feet below ground surface.
By going through the DEC's procedure of analyzing the potential
for contamination I arrive at the following points:
Ground Water
Soil Sorbtion
Permeability
Gradient
Separation
Total
(at 27 ft. )
3.0
( Silt )
3.5
( Silt )
2.0
( 0 )
2.0
( 97 )
3.0
13.5
==-=_=
Conclusion: Chemical contamination possible but unlikely.
As an added safe guard. Tank is a steel tank. Cast Iron
was used as well as water tight couplings.
Please issue an waiver for this well.
Yours
G
pipe
203
TE
- 4O" " •� R R L A VD9 720 �, i20A ANCHORAGE, ALASKA199501
. CONSULTING ENGINEER TELEPHONE: (907) 279-3916
i.
RESIDENTIAL WELL INSPECTION
-
�: � 0F At,qAtl
LEGAL: 'Lot '4A, Block 2, Boyle ••:
LOCATION: 12101 Wagner %*"��C., .H.�..�..
...OWNER - Jerry & Gloria Bauer �� : • o. 2225-E 'o
1 1;, JUNE 25.:971 `.�i
TYPE OF WELL: Residential. Single Family �•- .•��
i.
WELL LOG AVAILABLE: Yes
j INSTALLATION REQUIREMENTS MET: NO. Well is too close to septic
tank. 96 ft. vs. 100 ft..
Waiver applied for.
WELL YIELD FROM WELL LOG: 15 gallons per minute
PUMP YIELD FROM TEST: 7 gallons per minute
i
DATE OF INSPECTION: April 20, 1988
v
TEST PROCEDURE: Well was pumped at a constant rate while the
i
drawdown was monitored with an acoustic probe. At the beginning
of the test water level was found at 19 feet below top of casing.
At a pumping rate of 7 gallons per minute the water level dropped
to 33 feet after 15 minutes of pumping and remained at that
level,for the remainder of the test, 35 minutes. A total of 370
gallons were pumped. The well recovered instantaneously when
pumping stopped.
TEST FOR E.COLI AND TOTAL NITROGEN: Water was tested for E.Coli
and total nitrates on
E.Coli 0. Total Nitrates 1.4mg/1.
Max. allowable Total Nitrates 10mg/1.
TEST. RESULTS: This well meets.the requirements of the
Municipality of Anchorage.
THIS WELL WILL PRODUCE MORE THAN 3 GALLONS PER MINUTE FOR MORE
THAN FOUR HOURS
The Municipal requirement for well flow is 150 gallons of water
per bedroom per day. This well exceed this requirement. The
assessment of the condition of the well applies only to the
.conditions as of the day tested. The flow rate may change due to
subsurface conditions that may not be observed from the surface,
and changes in the land use and other factors that may impact the
aquifer feeding the well.