HomeMy WebLinkAboutTHOMAS L BOYLE BLK 2 LT 6A S2• � • � • � �J Municipality of Anchorage Page of 2 - DEPARTMENT OF HEALTH AND HUMAN SERVICES ENVIRONMENTAL SERVICES DIVISION P.O. Box 196650 * Anchorage, Alaska 99519-6650 • Telephone: 343-4744 On -Site Wastewater Disposal System and/or Well Inspection Report Permit Number. 5U% g80 `15'7 PID Number: 0/5- 282 - .36 Na1Te ar'o/d /-�a Wastewater System: ❑ New XLUpgrade Address: /0 hC%J r t ,� ABSORPTION FIELD Phone: - ?8 &,& 71 No. o Ba ms: T O Mound O Other O Deep Trench g Shallow Trencht�e1❑p LE AL DESCRIPTION Soil Rating:• y5 "Beed TFB +Ih-` ;O 61 QnEs: PD/S Ft. Lot: f.skil %vl • f Block: Subdivision: 5/� Delth to Dile iphpm from 011glnaI grade: EGk: /. re Z.44 Grev� I�ep th ben jPlh pipe LJESTT 4•D r L t< O Tp , Ft. 1 2.97 FI. Township: Range: Ion: Fill added above original grape: •rV Gravel length: /.•7 3.8 Ft,70 Ft. WELL tcfst:r ❑New ❑Upgrade Gravel width: Numberoflines: Detulcebetrm lines: 15 Ft, Ft. Classification (Privets. A.B.C): Total Delth: C o: Total absorption &me: Pips material: rr Ft. 9 O. Ft. Driller. tilled: Static Water level: In ta0er Ser Date Install /-�,'-9 — /-7-99 Ft. me / e Yield: mp Set at Casing Height Above Ground: TANK GPM Ft. Ft. SEPARATION DISTANCES Fl septic 0Holding 0S.T.E.P. To 8W`4: Absorption Lin, Holding Pubik,,Prhats Manufacturer. Gpacify In gallons: From Tsnk Field Station Tank a•w•r Un„ Welt /OOf N� — IO + Material: 5��� ♦ C Number of Compartments: urfacre WateLotv IDDe /00 4- — — —' LIFT STATION r Size In gallons: Manufacturer. / Une •F- 14- -' �' Foundation/ —„ —, "pump onIavel at: •Pump Hiph water alarm at: /- 'O f Curtain O n � �/Ro /� PumD Make 8 M ElWrical Inspections perfohned by. Drain Remarks: PP -2. Co.i A%,t-., BENCH MARK F it", ) & tow'rs CLOSER- -CF " 25' Lobation ane Osxrip(ion: •�r'o,--;t 0 r r we// FIZ.o-� 'tike wEL+- wFR� �cs�4�D to FrQ ]JI QE L'C1�a �TLo"1 Assumed Elevation. D++sK poNaa MSS • 1! IN BEwI , LOF�� 1 1 Inspections performed byf�bsE'., l✓ar� f ln�oslt4n Dates: 1st Vql'79 Cron SU/r&n4S,.1nG. 2nd /�-45-/99 ««w«• ..� Department of Health and Human Services appfdd �t1 Eo .w,•�r ��� Reviewed and approved by: IS&AI Date: / 30 -99 °+�osessto`e 727(rtw. aNt)MOA�S ,Sa/Ili I 0�� ���/� PERMIT -UMBER: SW980457 t ' 1 SHED r / D7 31.6 17.6 70.3 02 31.7 15.6 69.3 St 21.6 15.6 64.1 S2 21.9 19.1 58.2 CO 20.1 20.5 56.1 FS18.4 22.4 52.8 Lol 14.7 26.0 54.0 MT1 11.5 29.5 54.2 v 5irrefrw)i 4250-4'x.70 AV -BUILT DRAWING PARCEL 10 NUM 015-282—. TRENCHES \ WELL , WELL NOTE: THE ENTIRE NEW 1 SYSTEM WAS INSUU7ED. \\ �SHEO FCO \ IF EXISTING 2 1I BEDROOM yp1U5 WELT HOUSE /r/NL O'KR -96,05 5 / 512 -9580 mror - KNN-4555 f.751 i!'�V11 KNl!-4285 r vox (LNr 4580-4450 ww 1000 GALLON %m TANK „ wcp N,EYfQ T. 2 I (t `N 4205 40i10N Or M n" � 017TGE1 a 11OJ7: M6 at-&" t o-CBJI ALASKA WATER AND WASTEWATER CONSULTANTS, INC. 6901 DESARR ROAD, SURE 2B. ANCHORAGE, AK. 99504 PHONE: (907) 337-6179/FAX: (907) 338-3246 .LGAL DL5CR:PllON: BOYLE SUBDIVISION, LOT 6A, BLOCK 2 YPL OF WORK: DESIGN OF SEPTIC SYSTEM UPGRADE 'HLPARLU ICR: PHONL NUMULK: HAROLD HAYNES 345-6781/249-3667 JAIL: JNAMN by: l t: YA.L: 2/3/98 A.C.C. 1 = 40' 2 OF 2 e 4 -R7RfMX I KQIDl1."." K oluf-4260 1 7953 `$ .•• � cS4v� .� Municipality of Anchorage Department of Health and Human Services 825 "L" Street Rick Mystrom' P.O. Box 196650 Anchorage. Alaska 99519-6650 Mavor http:fl w xi.anchorage.ak.us AK Water & Wastewater Consultants, Inc. ATTN: Jeffrey Garness, PE _ 6901 De Barr Road, Suite 2B Anchorage, AK 99504-0000 June 30, 1999 Subject: Waiver Request forTHOMAS L BOYLE BLK 2 LT 6A S2 Waiver # WR990008 Lot Line Request for Parcel ID 015-282-36 Dear Engineer: Your request for a waiver of the required 10 feet horizontal separation of the on-site wastewater disposal system to the lot line has been approved. The approved separation distance is 1 feet. This waiver approval applies to the current on-site wastewater disposal system and lot line separation only. Any future upgrade to the on-site wastewater disposal system and lot line will require all separation distances to be met or another waiver approval from this department. If there are any further concerns or questions regarding this waiver, please call our office at 343-4744. Sincerely; Jeff Poet" ' a — e�— Engineering Technician III On -Site Water Quality Program 0(y\ MUNICIPALITY OF ANCHORAGE Department of Health and Human Services On-site Services Section Waiver Review Worksheet WR# j10ggrrn9, PID# HA# Permit # Date Received: �r F, Ci \C�gc1 Legal Description: /1 c PC 11 ff I Engineer: �\s�(-Y 1-ftnnoRv, _Znneo, �.t l�V{n (n 1y,nA,II -y r.,N(n ry --, Cnt- lt1q(_)\ Applicant: , n . \ A iJn .�//� S n -Fn \ ****** p P 1 n (� Waiver Requested: 'A 01 r\I t'Nt + i. -P �,-A � Z,, 4i,j Criteria: 1. Geology: A. Water Table B. Soil Sorption C. Permeability D. Water Table Gradient E. Horizontal Separation TOTAL: 2., Special Conditions: 3. Other: Points: Waiver is Granted: Waiver is NOT Granted: List Conditions or Reasons for above: Date: By: Name of Reviewer ****** Rec #: nL1(„4)<(M_)CpAmount: $ Date Paid:1�S.n� Permit Number: SW980457 MUNICIPALITY OF ANCHORAGE Department of Heafth and Human Services On -Site Services Program 825 L Street, Room 502 P.O. Box 196650, Anchorage, AK 99519.6650 (907) 343-4744 �i u� t11a-%}as-`ifs 1�C .23,9fs 3:ooprh ?Work ImPAe. . ONSITE WASTEWATER DISPOSAL SYSTEM PERMIT Upgrade Date Issued: Nov 25, 1998 Expiration Date: Nov 25, 1999 Parcel ID: 015-282-36 a P Yr.-, Legal Description: THOMAS L BOYLE BLK 2 LT 6A S2 LO Prr, Design Engineer. 0041 AK Water & Wastewater Consulta Site Address: 012210 CANGE ST f — cin Owner Name: HAROLD HAYNES Lot Size: 24900 SO. FT. Owner Address: 12210 CANGE STREET Total Bedrooms: 2 Permit Bedrooms: 2 ANCHORAGE. AK 99516-2033 This permit is for the construction of: Disposal Field Q Septic Tank ❑ Holding Tank ❑ Privy ❑ Private Well ❑ Water Storage All construction must be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal Code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72 ) and Drinking Water Regulations (18AAC80 ). 3. The engineer must notify DHHS at feast 2 hours prior to each inspection. Provide notification by tailing (907) 3434744 ( 24 hours ). ( Not required for a Water Supply Permit only ). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must be either. A. Open and closed on the same day. B. Covered, sealed, and heated to prevent freezing. Received By: Issued By: Date: 0 _ !G Date: — 2S ' /U Alaska Water & Wastewater Consultants, Inc. 6901 Debarr Road, Suite 211 -- Anchorage — Alaska 99504 (907) 337-6179 — Fax (907) 338-3246 Consulting Engineers November 25, 1998 Municipality of Anchorage Department of Health & Human Services Division of Environmental Services On -Site Services Section P.O. Box 196650 Anchorage, Alaska 99519-6650 Ref: Septic Design Upgrade for Boyle Subdivision, South 1/2 of Lot 6A, Block 2, To whom it may concern: The existing 2 bedroom house is served by a private septic system and a private well. The existing septic system is currently overflowing and must be upgraded immediately. We are requesting a expedited permit because of the potential health hazard. We also are requesting a 1 foot lot line waiver from the proposed drainfield to the north property he and a 5 foot separation distance waiver from the proposed west drainfield to the existing drainfield. As can be seen on the attached site plan and design there are no other options, besides installing a holding tank, for the location of a drainfield upgrade. Comment regarding the proposed upgrade are summarized as follows: 1. SOILS: Attached is a log which shows the soil profile, and the percolation tests results. The soils below the organic layer are a MUSM material to a depth of 14 feet (bottom of the test hole). No groundwater was encountered during the excavation of the test hole. After 12 days, the monitoring tube was checked and water was found at 13 feet. Two percolation tests were performed between the depths of 1.5 feet to 2.0 feet and 5.5 feet to 6.0 feet. The percolation rates were 30 & 60 minute/inch 2. TRENCH DESIGN: a. Percolation Rate: 30 & 60 minutestinch b. Allowable Application Rate: 0.45 gallons/day/ft2 c. Number of Bedrooms: 2 d. Design Flow: 300 gallons per day e. Minimum Absorption Area: 667ft2 f. Total Depth: 6 feet (max.) g. Effective Depth: 4 feet h. Width: 5 feet i. Minimum Length: 70 feet total length (2 @ 35 feet long each) j Effective absorption area = 700 ft (667 ft OK) 3. SURFACE WATERS: There are no surface waters within 100 feet of the proposed upgrade. 4. TOPOGRAPHY: As can be seen on the design, the average slope of the lot is a 3 to 4 percent slope running from east to west. In short, there are no slope concerns.. We are unaware of any adverse impacts this installation would have on adjacent wells or septic systems. If you have any questions, please contact us at 337-6179. Thank you for your assistance. Sincere I�l U 1 ames P. Williams, P.E. Civil Engineer ti II LOT 4B. BLOCK 2 LOT 3B. BLOCK 2 BOYLE S/D BOYLE S/D II I NORTH 1/2 OF LOT 5A, AR2D BLOCK 2, BOYLE S/O- C C II NORTH 1/2 OF LOT 6A. WELL (APPROX. I� I LOCATION) ' I 'BLOCK 2. BOYLES/D I� \ SOUTH 1/2 OF LOT 5A. BLOCK 2. BOYLE S/O DP�E%ISTRJ TMJ1 SEPTICSYSS \ell, TEM PROPOSED SEPTIC \ / /SYSTEM (SEE DESIGN. 9 PAGE 2 OF 2). EXISTING APPROX. LOC. I / ` 1 2 BHOUSEEDROOM 00 Z APPRax. LOT 58, BLOCK 2 I LOC. I I BOYLE S/O II \ LOT LOC 2 BOYLE II II II I y\o I �o�"5\0 I mot 000 LOT S. BLOCK 2 BOYLE S/D ry0�-(v ,\'L• I I\h• 5� II II II HUFFMAN ROAD ALASKA WATER AND WASTEWATER CONSULTANTS, INC. 8901 DEBARR ROAD, SUITE 28. ANCHORAGE, AN. 99504 PHONE (907) 337-8179/FAX: (907) 338-3248 _LGAL OLSCHIH14 : BOYLE SUBDIVISION, SOUTH 1/2 OF LOT 6A, BLOCK 2 IYPE OF WORK: SITE PLAN FOR SEPTIC UPGRADE DESIGN 'RLPARLD lOR: PHONL NUMtlLR: HAROLD HAYNES 345-6781/249-3667 .wit: JKAWN dY: SLAIL rALu 11/25/98 A.C.C./J.L.M. 1 = 100' 1 OF 2 I I 49 d :yl p. WES P. WIWAMFF NO. 9608 .I C.E. �o� d�1I O'1=691 BOYLE SUBDIVISION, SOUTH 1/2 OF LOT 6A, BLOCK 2 0 :' 49 ........ . . . 4 IYPL OF WORK: ` DESIGN OF SEPTIC SYSTEM UPGRADE p... .. t .. ............. 'NLPARLU FOR: PHONL NUMULN: TAMES P. WILUAM$F a HAROLD HAYNES 345-6781/249-3667 ��v NOCE 08 `A xlc11/25/98 1MWA C.G./J.L.M. ��� 1 = 40' rAi,c: 2 OF 2 �04p0 es.w NOTES: AM 1 20' 1) THE CONTRACTOR SHALL HAVE THE NORTH NOTE: A 5 FOOT WAIVER IS REQUESTED FROM I PROPERTY LINE AND THE 100' WELL RADIUS THE PROPOSED WEST DRAINFIELD TO THE I I I INSTALL FLAGGED BY A REGISTERED LAND SURVEYOR EXISTING DRAINFIELD. THERE ARE NO OTHER SEPTIC TANK SUCH THAT THE OUTLET PRIOR TO PRE -CONSTRUCTION SITE VISIT WITH OPTIONS FOR THE POSITIONING OF A NEW THE ENGINEER. DRAINFIELO. 2) All NEW PIPING IS TO BE INSTALLED FROM I °IVT THE EXISTING FOUNDATION CLEANOUT AND THE UNDISTURBED SOILS (SEE DIAGRAM). 5' ENTIRE PROPOSED SEPTIC SYSTEM IS TO BE I INSULATED. INo INSTALL S(ARU ULL RUN � DSL CO 3) THE CONTRACTOR IS TO FIELD VERIFY THAT EXISTING DRANFIELD TO REMAIN FOR ALL SEPARATION DISTANCES WILL BE MET PRIOR I I TO CONSTRUCTION OF THE UPGRADE / I I Cs'FPTIC ARI`&� / I' A NEW MONITORING TUBE IS TO BE \ / INSTALLED IN THE EXISTING DRA:NFIELD. -�. �• .� I LOT 6B, BLOCK 2 I PROPOSED TRENCHES � I / �^ 100' WELL RADIDS BOYLE S/D 2035'LONG BY 5' WIDE BY 6' DEEP WITH"" NORTH 1/2 OF LOT 6A, /EXISTING 4' OF CLEAN, WASHED , pOYLE SD BLOCK 2 / II SEWER ORNNR CK. 1 I SEPTIC TANK OF NEW 1000 GALLON cranr TANK - / NE SETBACK LOT UREQUESTED) I (WA'VER1* I 100' WELL RADIUS EXISTING / CLEAN-OUT, WELL NEW'� I I I I .�5- EXISTING FOUNOATION1 /\� C CLEAN-OUT \ \ I I I Nv `SHED (TPRO)(-, PRO. \\\r 0TO BE 5[I1iJL i LOUTON 1 II IIE MOVED 0� REMOVED. VT (:Q1TH%1 . -4% EXISTING 2 1 WE BEDROOM •� LFfTU- RADIUS HOUSE WFZ= —, r-li BOYLE SUBDIVISION, SOUTH 1/2 OF LOT 6A, BLOCK 2 0 :' 49 ........ . . . 4 IYPL OF WORK: ` DESIGN OF SEPTIC SYSTEM UPGRADE p... .. t .. ............. 'NLPARLU FOR: PHONL NUMULN: TAMES P. WILUAM$F a HAROLD HAYNES 345-6781/249-3667 ��v NOCE 08 `A xlc11/25/98 1MWA C.G./J.L.M. ��� 1 = 40' rAi,c: 2 OF 2 �04p0 es.w EXISTING SEPTIC TANK t5 TO BEWAGE PUMPED, CRUSHED, AND REMOVED WELL TO BE EXPOSED COMPLETELY. REPLACE WITH NEW 1000 -(A'•" I^ DECK) AM 1 20' f f f / I GALLON SEPTIC TANK. ROTATE NEW I I I INSTALL SEPTIC TANK SUCH THAT THE OUTLET I I I FLOW SPUTTER FACES NORTH AND INSTALL ON I °IVT UNDISTURBED SOILS (SEE DIAGRAM). 5' of T L k0 I INo INSTALL S(ARU ULL RUN � DSL CO EXISTING DRANFIELD TO REMAIN FOR VALVE IiTi�1 / FUTURE USE AS A RESERVE SITE o I' A NEW MONITORING TUBE IS TO BE \ / INSTALLED IN THE EXISTING DRA:NFIELD. -�. �• .� I LOT 6B, BLOCK 2 °�/—INSTALL �^ 100' WELL RADIDS BOYLE S/D J DBL co APPROXIMATE LOCATION WELL /EXISTING I II PROPOSED LOCATION 1 I SEPTIC TANK OF NEW 1000 GALLON cranr TANK ALASKA WATER AND WASTEWATER CONSULTANTS, INC. 690PHONER(907) 337SUITE 6 79/FAX: (07) 338 32423. ANCHORAGE. AK. 64 e�000ss00000 �I.,��•Or 'A�q��9o. BOYLE SUBDIVISION, SOUTH 1/2 OF LOT 6A, BLOCK 2 0 :' 49 ........ . . . 4 IYPL OF WORK: ` DESIGN OF SEPTIC SYSTEM UPGRADE p... .. t .. ............. 'NLPARLU FOR: PHONL NUMULN: TAMES P. WILUAM$F a HAROLD HAYNES 345-6781/249-3667 ��v NOCE 08 `A xlc11/25/98 1MWA C.G./J.L.M. ��� 1 = 40' rAi,c: 2 OF 2 �04p0 es.w WATER & WASTEWATER CONSUL: I ZUIL Lw — rLK6ULAi iUn I w I I LEGAL DESCRIPTION: BOYLE SUBOMSION, SOUTH 1/2 OF LOT 6A. BLOCK 2 PERFORMED FOR: HAROLD HAYNES DATE PERFORMED: 11/7/98 D(toe et1 TEST HOLE #71 1 I ORG PAGE I OF 2 2 3 4 5 6 11 12 13 14 15 16 17 18 DEPTH TO ROLINDWATER B.O.H.DATE SOIL CLASSIFICATIONS o .o GW DRY ORG _c__: 11/18/98 ' GP 1111111 ML r,116;1 GM /, CL 1 5:55 — GC 111 OL 2 6:25 30 SW SITE PLAN MH I 'O100' 1, �• o 6' — OH ML/SM 4 to S _ _ VERY DENSE SILT ✓✓o3Zd SC W/ FEW SILTY SAND 6 7:25 30 POCKETS/LENSES DEPTH TO ROLINDWATER B.O.H.DATE READING DRY 11/7/98 13' 11/18/98 LE WAS PRESOAKED 4+ HO LOCK 2, BOYLEI S/D DATE READING CLOCK NET TIME TIME (MINUTES) Irs� ARE!D 1/9/98 NOR�N 172 OF�.&A, LE WAS PRESOAKED 4+ HO LOCK 2, BOYLEI S/D TH/1 P I 1 5:55 — 6' — 2 6:25 30 5 1/4' 3/4' SITE PLAN I I 'O100' 1, DATE READING CLOCK NET TIME TIME (MINUTES) WATER LEVEL NET DROP READING (INCHES) 1/9/98 PERC. HC LE WAS PRESOAKED 4+ HO JRS PRIOR TO TE STING 1 5:55 — 6' — 2 6:25 30 5 1/4' 3/4' _ _ 3 6:25 — 6' — 4 6:55 30 5' 1' _ _ 5 6:55 — 6' — 6 7:25 30 5' 1' 19 —� I PERCOLATION RATE 30 (MIN./INCH) FERC. HOLE DIA. 6 (INCHES) 20—fl—jl TEST RUN BETWEEN 1-5 FT. AN 2.0 FT. COMMENTS: it PERFOMED BY ALASKA WATER do WASTEWATER I,VUJAY—"n - CERTIFY THAT THIS WAS PERFOR ED N ACCORDANCE WITH ALL T AND MUNICIPAL GUI EUNES IN EFFECT ON THIS DATE. DATE o► .• I AI.ASRA 'ASTEWATER INC. SOIL LOG — PERCOLATION TEST LEGAL DESCRIPTION: _80YLE SUBDMSION, SOUTH 1/2 OF LOT 6A, BLOCK 2 PERFORMED FOR: HAROLD HAYNES DATE PERFORMED: 11/7/98 (EM feet) ITEST HOLE #1 1 PAGE 2 OF 2 y DATE SOIL CLASSIFICATIONS NET DROP (INCHES) 11/11/91 • GW - c: ORG 3 STING • . •' GP 111111, ML r,11w,GM !// CL 4 —_ 7574! GC '1'1' OL 6' 5 1/2' - 1/2' •` SW I I MH 5k4wv 2:37 — 6' SP CH _ _ 4 tis SM OH 6 1/2' Sc N 6 u - O 9 10 LJ (7 Q 11 � w w 12 (n 13 14 15 16 17" 19 20 COMMENTS: PERFOMED BY ALASKA THIS WAS PERFOR ED DATE. DATE DEPTH TO GROUNDWATER DATE SEE PAGE 1 OF 2 NET DROP (INCHES) 11/11/91 PERC. HC LE WAS PRE SOAKED 4+ HO JRS PRIOR TO TE STING SEE PAGE 1 OF 2 DATE READING CLOCK NET TIME TIME (MINUTES) WATER LEVEL READING NET DROP (INCHES) 11/11/91 PERC. HC LE WAS PRE SOAKED 4+ HO JRS PRIOR TO TE STING — — -_ —_ 1 2:07 — 6' 5 1/2' - 1/2' 2 2:37 30 3 2:37 — 6' — _ _ 4 3:07 30 5 1/2' 1/2' 5 4:07 60 4 1/2' 1' PERCOLATION RATE 60 (MINJINCH) TEST RUN BETWEEN f 5.5 FT. AND TER do WASTEWATER I, ACCORDANCE WITH ALL PERC. HOLE DIA. 6 (INCHES) I.e. CERTIFY THAT I EFFECT ON THIS MUNICIPALITY OF ANCHORAGE ' DEPARTMENT OF HEALTH & ENVIRONMENTAL PROTECTION ENVIRONMENTAL ENGINEERING DIVISION 825 L Street - Anchorage, Alaska 99501 Telephone 264-4720 ONSITE SEWAGE DISPOSAL SYSTEM AND/OR WELL INSPECTION REPORT NAME t W PHONEp -� /8 NEW ❑UPGRADE MAILING =ESS I ^ LEGAL DESCRIPTION / 4C1()/l�.�. C /� lJl L LOCATION NO. OF BEDR OMS Use DISTA CE TO: Well (poir Absorption area DwellingI I O PER T O 7 _ aQ E� Manufacturer Material No. of compartw�nts O/ Liq. a gallons IF HOMEMAD : Inside length Width Liquid depth d Y J v Z DISTANCE TO: Well Dwelling PERMIT NO. I=FQ- Manufacturer Material Liquid capacity in gallons d W = DISTANCE TO: Well Foundation Nearestlothne / PERMI f 2 W No. of lines Lang at_h{lin / 7' Total length of ines I Trench widt Chas Distance twee nes Q¢ f o Top of tile to finish grade I Material beneaththe aches Total effective bsor do arty L f� W 0 Length Width Depth PERMIT NO. Q H W d Type of crib Crib diameter Crib depth Total effective absorption area DISTANCE TO: Well Building foundation Nearest lot line J J Class Depth Driller Distance to lot line PERMIT NO. W DISTANCE TO: Building foundation Sewer line Septic tank Absorption area(s) OTHER PIP MATERIALS .Vr, A17 D Z72 f SOI L TEST RATING Orn Vill-eHrCrM INST L REMARKS n' o ' v' 1 hu Aim 6v?ni% F: g APPROVED DATE LEGAL Crilober-17,8 i I lr)i110 72-013 (Rev. 3/76) I'1ut-7I C. I /"1L_ I TY OF nY4GH "fZFfCiE DEPARTMENT 6. HEALTH AND ENVIRONMENTAL r.ATECTION 3 825 'L' STREET, ANCHORAGE, AK. 99501 264-4720 GFJ—'S I TE 0EWEFZ F'EFRII I T PERMIT NO. C =762:-) APPLICANT CAROL D. WILKINSON SRA BOX 1548-E ANCH. 265-4187 LOCATION LEGAL LOT 6A ELF; 2 BOYLE SUB LOT SIZE 999999 SQUARE FEET TYPE OF SOIL RESORPTION SYSTEM IS: TRENCH MAXIMUM NUMBER. OF BEDROOMS = 3 SOIL RATING CSO FT/BR)= 200 THE REQUIRED SIZE OF THE SOIL ABSORPTION SYSTEM IS: GEFlTH= i LEtJCiTH= 75 GRFik EL GEF?IF"= 4 THE LENGTH DIMENSION IS THE LENGTH CIN FEET) OF THE TRENCH OR DP,AINFIELD. THE DEPTH OF A TRENCH OR PIT IS THE DISTANCE BETWEEN THE SURFACE OF THE GROUND AND THE BOTTOM OF THE EXCAVATION CIN FEET). THERE IS NO SET WIDTH FOR TRENCHES. THE GRAVEL DEPTH IS THE MINIMUM DEPTH OF GRAVEL EETWEEN THE OUTFALL PIPE AND THE BOTTOM OF THE EXCAVATION CIN F9ET). FcEI}!U I F<EG S.EF'T I �- THF -.IF, � I �E_. 1Fa� Fa GFiLLOtiS} PERMIT APPLICANT HAS THE RESPONSIBILITY TO.INFORM THIS DEPARTMENT DURING THE INSTALLATION INSPECTIONS OF ANY WELLS ADJACENT TO THIS PROPERTY AND THE NUMBER OF RESIDENCES THAT THE WELL WILL SERVE. --- TWO xz 2= 7 I t4foF'ECT I CAtJ"3 FA Fm a: ' FzE:(PU I REG --- BACKFILLING OF ANY SYSTEM WITHOUT FINAL INSPECTION AND APPROVAL BY THIS DEPARTMENT WILL BE SUBJECT TO PROSECUTION. MINIMUM DISTANCE'SETWEEN A WELL AND ANY ON-SITE SEWAGE DISPOSAL SYSTEM IS 100 FEET FOR A PRIVATE WELL OR 150 TO 200 FEET FROM A PUBLIC WELL DEPENDING UPON THE TYPE OF PUBLIC WELL. MINIMUM DISTANCE FROM A PRIVATE WELL TO A PRIVATE SEWER LINE IS 25 FEET AND TO A COMMUNITY SEWER LINE IS 75 FEET. OTHER, REQUIREMENTS MAY APPLY. SPECIFICATIONS AND CONSTRUCTION DIAGRAMS ARE AVAILABLE TO INSURE PROPER INSTALLATION. F E=FTtl I T EXF=> I FSE GECE1lE3EF;Z: = 11 =1.'_L . I CERTIFY THAT is I AM FAMILIAR•WITH THE REQUIREMENTS FOR ON-SITE SEWERS AND WELLS AS SET FORTH BY THE MUNICIPALITY OF ANCHORAGE. 2: I WILL INSTALL THE SYSTEM IN ACCORDANCE WITH THE CODES. 3: I UNDERSTAND THAT THE ON-SITE SEWER SYSTEM MAY REQUIRE ENLARGEMENT IF THE RESIDENCE IS REMODELED TO INCLUDE MORE THAN -s BEDROOMS. SIGNED APPLI ISSUED BY CAROL D. WILKINSON V4. 0 f� SOILS LOG MUNICIPALITY OF ANCHORAGE • DEPARTMENT OF HEALTH AND ENVIRONMENTAL PROTECTION ❑ PERCOLATION TEST 825 L. Strom, Anchorage, Alaska 89501 2644720 SOILS LOG - PERCOLATION TEST PERFORMED FOR,non on t 1V-l.I\ � � I/ DATE PERFORMED: � u V 3 LEGAL DESCRIPTION: QoVle f-ki 'iyi-s1or1 [boil Z Lo+ &A 5112 -' SLOPE j SITE PLAN 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 (OL) NO brown si 11 O=Siona15 aVC15 becoming Plush( - ((am) very dense Slli, qravels and toWles WAS GROUND WATER Alp L ENCOUNTERED? O P IF YES, AT WHAT E DEPTH? --A# Reading Date Gross Time Net Time Depth to Water Net Drop PERCOLATION RATE TEST RUN BETWEEN FT AND FT PERFORMEDBY: VV//Ul� l.L(/'/JU// CERTIFIEDBY: DATE: Ll V6'j_ M014 5T 3 -Oz / D3 / 7z-goe (6/79)ODS LOT (DA Th Z 1 2 ----�3 4 5 6 8 9 10 1: 1: p V li 1' 1 1 2 ALASKA EI � R011MMAL COIITROL SERVI�EB, Inc. Engmetrinq t'. Enu:ronmemal Studies Supplemental Soils Information. Subdivision h `J LOT Block Z LOT TH 711 COL, DEPTH (FEET) DEPT" (FEET) (ML) , 1 brown silt z dry,few z 9r0.vCl5 3 3- 20D dlbdyw 4- 5- 5 (50) 150a,lbdrtt6 6l 7 (4M) tro�e e y 9 9 (W) to 10 ve dense Qr�ie►►Asue11 11 l�r,Q cob►es 1z 12- 13- 13- 14- 14 15 V 15 J 16 16- 17- 17- 181 18 19 19 in 20 U U 0'00 11s1 33rd Avenue. Suit6 An6cragt, Alasla 99503 • (907) 2761361 LOT 7 t� 2 3. 4 5' 6 7 e 9 10 12 13 14 15 16 17 18 19 20 I ALASKA EnUIROWI)TAL COnTROL SERUICES, Inc. Enginecrinq 6 Environmental Studio PERCOLATION TEST DATA SHEET CLIENT Cion Mack DATE SU113. I9R3 ADDRESS ` ZIP CODE LEGAL LOCATION (Flock Z. Lof 6n 5'/z. TOTAL DEPTH OF HOLE v ft. ZONE TESTED V2 ft TO ft T 2 V1 diaxnei-er hole READING A CLOCK TIME NET TIME DEPTH TO DATUM NET DROP RATE (min/in) 1-Hs052S r z 2 5 27 /Omit. /0 /!7%/!• .5o go • 50 2 .10 . o q 2p. 8 4.N:o 5.3s /D min, ;ySO •09 •50 . 12 11 6;05 /0 min. •'0 FINAL PERCOLATION RATE . l ' (min/in) PERFORMED BY l .huc.k C0.61SoYl 200 ❑'/ bed roorn !-4 =0 Wast 33rd Avenue. Sui.:•,F• Anchoragt. Alaska 99503 • (9071276-1361 n r ime APPLI(14�,NT FILLS OUT UPPER HAI'ONLY Time Time Property Owner /1 �\ �, (✓(,, i.li' ( L `". 1 Ai ..(_ J A% +;7 rPh I,._,`^�� '�v ,� Zip Code Mailing Atltlress ..'.� �%f-1`�\: inspector Buyer Y :..i..Ll . � ". CL. CrC. � Address Zip Code Lending Institution \L .1 _i 1-- "� -_: -� +�-� �_ JA r—i (�' Phone Address ZIP Code It Realty Co. d Agent ,r Phone Address Zip Code Legal Description SZ �`- L � L, �, n I(` 2 r' !Y 'CONDITIONS OF APPROVAL Street Location Type of Residence t C],'Single Family (� �' BY: ctb'n n `riT ❑ Multiple Family No. of Bedrooms ❑ Other Oate Installed Well To Absorption Area /' 4 --Da Water upply Septic Tank Size -;� 0 / t Individual ATTACH WELL LOG. A well log Is required for all wells drilled since June 1975. ❑ Community For wells drilled prior to that date, give well depth (attach lop If available). ' ❑ Public Utility Sewer Disposal i?nYaciC �y>^ Gi'Individual Year Individual Installed: Il ❑ Public Utility When Connected to Public Utility: ❑ Holding Tank NOTE: THE INSPECTION FEE MUST ACCOMPANY EACH REQUEST BEFORE PROCESSING CAN BE INITIATED. n r ime Time Time Time Date Date Date Date Inspector inspector Inspector Inspector Field Notes: MUNICIPALITY OF ANCHORAGE CEPT. OF H`!•.LTII Y. ENVIROX�d=NTAL PROTECTION i OCT IS 1033 A dam' RECEIVED. .amu ( 3) APPROVED BEDROOMS 'CONDITIONS OF APPROVAL ( ) DISAPPROVED ( ) CONDITIONAL APPROVAL' DATE z--s-g3 (� �' BY: ctb'n n `riT Solis RatingSewer Oate Installed Well To Absorption Area /' 4 --Da Well Lop Received Septic Tank Size -;� 0 / t Well to Tank M October 25, 1983 Carol wilkinson SRA Box 1548-E Anchorage, AK 99507 Subject: Boyle Subdivision Block 2 Lot 6 A Skil Approval for the individual sewer and water facilities cannot be granted until the following items have been completed: ;he septic tan), pumped with a receipt submitted to this department. ° Expose the well for our inspection to determine proper tr construction, also to insure minimum distance requirements are met between the well and sewer system. I: (nae L02Ls ease notify this department for a reinspection when the noted discrepancies have been corrected. If there are any further questions, please call this office at 264-4720. 1 A Sincerely, Jim Roberts Associate Environmental Specialist ' JR94IPIE1I z- J i � f �(j 1 14 Mi ticipality of Ancho^age MEMORANDUM DATE: December 8, 1983 TO: Laura Crow FROM: Environmental Health Division SUBJECT: Request for Refunds - Account # 2460 Please make the following arrangements for refunds: (1) They paid twice for their 1983 Excavator's Permit. Acreage Systems, Inc. 601 East Northern Lights Boulevard #165 Anchorage, Alaska 99503 Receipt #267502 Amount: $10.00 Account # 2460 (2) They had a private engineer do the inspections for the installation of the on-site sewer system. Carol D. Wilkinson Star Route A Box 1548-E Anchorage, Alaska 99507 Receipt # 247415 Amount # 20.00 Account # 2460 Laura J. Ward Office Associate attachments 81-010 14/76) Sewer permit #830725