HomeMy WebLinkAboutTHE TABLELANDS BLK 5 LT 3Onsite File � f W Y IRMW r Alk . Municipality of Anchorage WOW On -Site Water and Wastewater Program • (907) 343-7904 5 Page of ON-SITE WASTEWATER INSPECTION REPORT JUL ,1 6 2018 Permit Number: SW040219 PID Number: 05181161 Dwelling: ❑■ Single Family (SF) ❑ Duplex (D) ❑ Multiple (SF and/or D) Project: ❑■ New ❑ Upgrade Name: Rodger Sullivan ABSORPTION FIELD ❑ Deep Trench El Shallow Trench EJ Bed E] Mound Address 23342 Muley Cir Chugiak Alaska 99567 ❑■ Other Phone Number of Bedrooms Soil Rating Total depth from original grade 907-39-00301 5 0.6 GPD/SF 10.2 Ft. LEGAL DESCRIPTION Depth to pipe invert from original grade 6,2 Ft.4 Gravel depth beneath pipe Ft. Subdivision Block Lot The Tablelands Block 5 Lot 3 Fill added above original grade See Dwg Ft. Gravel length (2) C«@ 69' Ft. Township Range Section T 15 N R 1 W Sec 4 Gravel width 5 Ft. Beds: Number of Lines NA Distance between lines NA Ft. SEPARATION DISTANCES To Septic Absorption Lift Station Holding Sewer Total absorption area Number of trenches Dist. between trenches From Tank Field Tank Line 1380 Ft2 2 10 Ft. Well NA NA NA NA NA TANK ❑■ Septic ❑ S.T.E.P. ❑ Holding ❑ Other Manufacturer Anchorage Tank Capacity 11500 Gal. Surface Water +100' +100' NA NA Material Steel Number of compartments 2 Lot Line 31.3' 10.0' NA NA NA Foundation 11.4' 22.6' NA NA LIFT STATION Manufacturer NA Capacity NA Gal. Curtain Drain NA �Unkown� NA NA Remarks5' Wide Trench Pump on level at NA in. Pump off level at NA in. High water alarm at NA in. Pump make and model NA Electrical Inspections performed by NA PIPE MATERIAL House to tank D3034 Tank to D3 drainfield 034 Installer Unknown Drainfield D3034 CO/MT Inspector Rod Kinney, Chris Kinney BENCH MARK (Assumed elevation) 300.5 ft Inspection 15' 7/l/04 8/12/04 Location and description 2ntl 3`e 8/13/04 4" 8/13/04 Garage Finished Floor COMMUNITY DEVELOPMENT DEPARTMENT APPROVAL Engian g' Stamp Conditional Approval: Date? •• •: 'V • q • Y s4A NaD a .. 3660 O ®6000 040 OOQ@i wift is °s Approved tivL,6b LDate '� i (� 8 •41 d� ; • ° � ► Inspection Report_9-1-12.doc 33' SECTION EASEMENT o\ I I V\ I I 1 HOUSE I I I LOT 4 I I \ I I \ to I I I I m � I � 1 � I� \ 1La I I lu LOT 5 I � m IIUI I :d.Q, PROPERTY LINE ADJACENT PROPERTY LINE - - - - - - - EASEMENT SETBACK RIGHT-OF-WAY CENTERLINE -----300----- CONTOUR (20' MAJOR) CONTOUR (4' MINOR) s TBM-GARAGE F.F. = 300.5' ,,,—WETLANDS ID 102 �'A' DESIGNATION h � I I I lU I I W I —15' UTILITY V I j I EASEMENT Q) I LOT 1 I LOT 6 GRAPHIC SCALE 100 0 50 100 1 inch = 100 feet SEPTIC, SEE FIGURE 2 GLENN VIEW ES TA TES NOR TH SUBDI VISION TRACT C - AS—BUILT low OF `\7k\ 4 TH d............... �, p .Rodney P. Kinney Jr.: 1 �f• CE7955 q % P'Ofessio LOT 3, BLOCK 5, SITE PLAN Og) RodneYP. Kinney AssociatetilL THE TABLELANDS SUBDIVISION COOftl11100 Eo01n@@r$ s SMOVOrS (PLAT 2004-25) ANCHORAGE RECORDING DISTRICT 7�6�2018 FIGURE 1 I I I 10' SETBACK I I C0#6 CO#7 I I0 MT#1 15.3' I 4 I -v I � A< I I / `96, ' 4 I S CO#4 P � I � LOT 4 22.5' ELBOW CO#3 I CO#2 ST I � I Q 2g6 \ n SWING TIE TABLE STRUCTURE OCORNER @CORNER CO#1 34.4' 19.3' CO#2 19.9' 51.4' CO#3 21.0' 52.3' CO#4 27.9' 64.3' CO#5 30.5' 52.5' CO#6 96.1' 118.2' CO#7 97.1' 112.5' FS#1 23.2' 55.1' ST#1 17.8' 38.4' ST#2 18.5' 48.1' MT#1 85.7' 109.9' MT#2 41.8 60.6' n NEW TOP OF SLOPE NOTES: 0 \ \\ SEE THE SET BACK A Z \ DETAIL IN THE ORIGINALLY SUBMITTED SITE PLAN FOR THE ON-SITE SEWER \ 2 \ \ PERMIT APPLICATION. M T#2 OLID \ 1 VC CO#5 FS#1 1.8 L.F. 4" SOLID PVC 5.3 L.F. 4" SOLID PVC \ LOT 3 #2 1500 GAL SEPTIC TANK` ST#1 22.7 L.F. 5.7 L.F. 4" SOLID PVC 4" SOLID 45' ELBOW PVC O AS -BUILT I \ OF .4 HOUSE /���� . • • • ... I 4%9T� �i i Ri l......... ................. IA Vo '. Rodriey P. Kinney Jr..' �c so GRAPHIC SCALE 20 CE7955 14 40, 1AW e 11 lofessio�� 1 inch = 20 feet \������� LOT 3, BLOCK 5, SEPTIC LAYOUT RodleYP. Kinney Associatet ioc. THE TABLELANDS SUBDIVISION Consulting Engineers a Surveyors (PLAT 2004-25) ANCHORAGE RECORDING DISTRICT 7/6/2018 FI GURE O O O O O O O 00 00 `r) r7 r7 N N N N _ ............�.. .... . . . . . . . . . .I . . . . .II ........� > o rn I co N 1 II I II J J J !, w I . :.....^....I.........I........ . 00 T3SflOH 00)M� 11 1 10 01 1 1 1 1 N o � N Ki _ W H Z � Q Z � O Fw- w > 1-- < Q w U X Y W U Of O w o a m Lj 00 H WO W LLJ CD Q 0C 3:: N Ld 0 >- a za O a fz z 0O =O w¢ �> U W Q O O X z zw N AS—BUILT �,0K`A ZL x OR 9TH V6 '. Rodney P. Kinney Jr..' �-4 a',• ' • CE7955 q LOT 3, BLOCK 5, PROFILE RedleYP. Kinney AssocimilL THE TABLELANDS SUBDIVISION Csaseltlr0 Engineers a Surveyors (PLAT 2004-25) 7 6 2018 FIGURE ANCHORAGE RECORDING DISTRICT V ! U w Q N co ............. I.. p I: � .II... .Q N I. _j w 11. w 0_ w co WOJ °° N - J i — w t7 o! . ....... ..........�.........I........ sem- ---J. o c � J. .-- G W �J J 00 w N0- (n > . . . . . . . . . . . . . . . . . . . . . . . . . . . .. . . . . . . . . . . . . U �' zw as � . (9 N. �0 OU w II. OCA Lna w. w N �. w 00 UD �. �. o Q o N m DD 00 N N. Z II N II LJ W W W U > . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .O J U00 0 : CL o O _ II of W. . . . . LL . . . . .6. . . . . . . . .0) . . . . . . . . . . . . . . .N L` r .6 W U N N LO <II ; II w w 00 T3SflOH 00)M� 11 1 10 01 1 1 1 1 N o � N Ki _ W H Z � Q Z � O Fw- w > 1-- < Q w U X Y W U Of O w o a m Lj 00 H WO W LLJ CD Q 0C 3:: N Ld 0 >- a za O a fz z 0O =O w¢ �> U W Q O O X z zw N AS—BUILT �,0K`A ZL x OR 9TH V6 '. Rodney P. Kinney Jr..' �-4 a',• ' • CE7955 q LOT 3, BLOCK 5, PROFILE RedleYP. Kinney AssocimilL THE TABLELANDS SUBDIVISION Csaseltlr0 Engineers a Surveyors (PLAT 2004-25) 7 6 2018 FIGURE ANCHORAGE RECORDING DISTRICT EL. =289.3' EL. =285.3' BOTTOM OF TRENCH 5 5' M T#1 M T#2 EXISTING GROUND J �i i NATIVE SOIL,_ I/ NATIVE SOIL BACKFILL ,i w / BACKFILL , 8" GRAVEL 00 CL o Li _ w a > 3 m FINISH GRADE LEVEL 4" PERFORATED PIPE FILTER FABRIC, TYP. 1/2" TO 2-1/2" SCREENED, TYP. 10' 15.3' 4 z A SEASONALLY HIGH STATIC A GROUNDWATER TABLE BEDROCK OR OTHER IMPERMEABLE BARRIER SS�SS�SS�SS�iS SS�SS�SS�iS�SS, 5' WIDE TRENCH SECTION A -A DESIGN CRITERIA: 5 BDRM = 750 GPD SOILS = 0.6 GPD/SQ. FT. LENGTH REDUCTION FACTOR = 0.5 750/0.6 = 1250 SQ. FT. 1250 x 0.5 = 625 SQ. FT. 625 SQ. FT. + 10% = 687.5 SQ. FT. MAX GRAVEL DEPTH = 285.3' MIN. DEPTH 4' EFFECTIVE 5' WIDE 138' TOTAL TRENCH LENGTH - (1) 69' = 69' 1 69' = 69' 138' NOTES: SEPTIC SYSTEM INSTALLED IN ACCORDANCE WITH MOA WASTEWATER DISPOSAL CODE (AMC 15.65). -NTS- 10, NTS - AS -BUILT �* 4 9TH � Rodney P. Kinney Jr.: �4 I oa°1• ' • • CE7955erl q % LOT 3, BLOCK 5, 5' WIDE TRENCH IOWA Kinney Ameciates, inc. THE TABLELANDS SUBDIVISION CROSS SECTION Consulting Engineers a Surveyors (PLAT 2004-25) ANCHORAGE RECORDING DISTRICT 7/6/2018 FIGURE 4 �- Rodney P. Kinney Associates, inc. Consulting Engineers a Sureevors July 6, 2018 Municipality of Anchorage Development Services Department On -Site Water and Wastewater Program 4700 Elmore Road Anchorage, Alaska 99507 Attention: Becca Carrol Subject: Alternate Disposal Field Soil Percolation Rate The Tablelands Subdivision, Block 5, Lot 3 Chugiak, Alaska 99567 Acceptance of As -Built and Inspection Report Dear Becca Carrol: The purpose of this letter is to demonstrate that the proposed alternate disposal field location for the subject property is likely to have soils consistent with soils found in the area, in lieu of conducting a test hole. Attached for your use are the following items: 1. RPKA Inspection Report 2. As -Built 3. Supporting Historical Soil Logs — Percolation Test Reports The enclosed Inspection Report and As -Built are for the conventional wastewater disposal system for residential structure totaling five (5) bedrooms located on property and which is privately owned by Rodger Sullivan. Reviewed percolation rates in the area range from 4 to 28 min/in. It appears that as the poorly graded sand with gravel becomes siltier, the percolation rate increases. Based on the reports reviewed, percolation rates and soil logs for the area suggest that the time required to percolate water in the poorly graded sand with gravel also tends to increase with depth. Of the soil logs reviewed, no impermeable layers were detected. The typical soil profile for the area is composed of 6 to 12 inches of organic soil followed by a combination of varying percentages of sand, gravel, and silt. The soil logs suggest an increase in fine particle sized materials from north to south and west to east, however, the soil logs consistently show that percolation rates are within acceptable ranges in the area. 16515 Centerfleld Drive ■ suite 101 ■ Eagle River, Alaska ■ 99577 907.694.2332 1 Fax 907.694.1807 1 www.rpka.net Alternate Disposal Field Soil Percolation Rate The Tablelands Subdivision Block 5 Lot 3 Chugiak, Alaska 99567 Acceptance of As -Built and Inspection Report Page 2 of 2 Please contact me if you have any questions at: Rodney P. Kinney Associates, Inc. 16515 Centerfield Drive, Suite 101 Eagle River, Alaska 99577 Phone: (907) 694-2332 Email: jaredk@rpka.net Sincerely, RODNEY P. KINNEY ASSOCIATES, INC. Jared Kinney, EIT, AK-CESCL Attachments: • Soil Log — Percolation Test: Tablelands Subd. Bk5Lt2 • Soil Log — Percolation Test: Tablelands Subd. Bk5Lt3 • Soil Log — Percolation Test: Tablelands Subd. Bk5Lt4 • Soil Log — Percolation Test: Tablelands Subd. Bk 5 Lt 5 (TH 2, TH 3, and TH 4) RPK:jbk Rodney . Kinney, Jr., P.E., S.E. Principal . OF -w%, 49TH �y*) ...... . .... / .. ......... ,p Ro ey P. Kinney Jr..' (I��• '• CE7955 q 11`\� �'+'ofessiori�� Permit Number: SWO40219 MUNICIPALITY OF ANCHORAGE Development Services Department On -Site Water 8 Wastewater Program 4700 South Bragaw Street P.O. Box 196650, Anchorage, AK 99519-6650 (907) 343-7904 ONSITE WASTEWATER DISPOSAL SYSTEM PERMIT Initial Date Issued: Jun 24, 2004 Expiration Date: Jun 24, 2005 Parcel ID: 051-811-61 Legal Description: THE TABLELANDS SUBDIVISION BLOCK 5 LOT 3 Design Engineer: 0018 Rodney P. Kinney Associates Site Address: 23342 MULEY CIRCLE Owner Name: ROGER & BRENDA SULLIVAN Lot Size: 400002 SQ. FT. Owner Address: 23342 MULEY CIRCLE Total Bedrooms: 5 Permit Bedrooms: 5 CHUGIAK , AK 99567 - This permit is for the construction of., Q Disposal Field ❑✓ Septic Tank ❑ Holding Tank ❑ Privy ❑ Private Well ❑ Water Storage All construction must be in accordance with: 1. The attached approved design. 2. All requirements specked in Anchorage Municipal Code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72 ) and Drinking Water Regulations ( 18AAC80 ). 3, The engineer must notify DSD at least 2 hours prior to each inspection. Provide notification by calling (907) 343-7904 ( 24 hours ). ( Not required for a Water Supply Permit only). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must be either: A. Open and closed on the same day. B. Covered, sealed, and heated to prevent freezing. 5. The following special provisions. 1.) AT THE TIME CONSTRUCTION THE ENGINEER SHALL PERFORM AN ADDITIONAL PERCOLATION TEST IN ACCORDANCE WITH AMC 15.65 FOR THE ABSORPTION FIELD UPGRADE SITE. 2.) THE MAXIMUM DEPTH FROM ORIGINAL GRADE TO THE BOTTOM OF THE PROPOSED ABSORBTION FIELD SHALL BE, TFEET. lZe /{00 /UNd1BYTR. 5Tfi7F_S IfF IS CVAs VIAICEd 79i97- 6RovND wliTFiq /s Ivor n FacTofr Mepm(.H Dlbb1N6 ;-Hc- i-FSi H0,4,6 IAe4*r ,400 MoN' Or¢1A•&, 7,v EARGr XuAN,(_ IN THL- I-E.T r Holp Foie Ago06tiv& Received By: Issued By: t 0x10121a1- neart w14rr-R, ruF' soil Date: 4. 12,/ o Y, Date: IO 2¢ O4 Municipality of Anchorage Development Services Department Building Safety Division i On -Site Water and Wastewater Program 4700 South Bragaw St. P.O. Box 196650 Anchorage, AK 99519-6650 www.ci.anchorage.ak.us (907) 343-7904 ON-SITE SEWER/WELL PERMIT APPLICATION FOR A SINGLE FAMILY DWELLING Parcel I.D. 0.5- I— R (f - (e% Permit Number SW 040219 Property owner(s) - 4 94041cj& Day phone 6W-05'1�K Mailing address (1) 10yl f /4o /-k � C. r. SITE dweifim address (2) 23.34?- L E 1 ROLE Zip Code 77 Legal description (Lot, Block & Sub'd.) L Z 9 f ) c-S(e- Legal description (Section, Township & Range) Lot Size 40, 00 2 Acresq.Ft). Number of Bedrooms <� THIS APPLICATION IS FOR: Sewer Only ® Well Only ❑ Sewer and Well ❑ Water Storage ❑ Sewer Upgrade ❑ THIS PROPERTY CONTAINS: Hot Tub ❑ Jacuzzi ❑ Swimming Pool ❑ Water Softening Unit ❑ Therapy Pool ❑ I certify that the above information is correct. I further certify that this application is being made for a Single Family Dwelling and is in accordance with applicable Municipal Codes. of property owner or authorized agent) Permit Fees: Date of Payment: 46. l7/0¢ Receipt Number. Os -3 8 gr (Rev. 12/00) Waiver Fees: _ Date of Payment: Receipt Number: June 6, 2004 Municipality of Anchorage Development Services Department On -Site Water and Wastewater Program 4700 S. Bragaw Street Anchorage, Alaska 99519-6650 Subject: Request for Review and Approval for Onsite Wastewater Lot 3, Block 5, The Tablelands Subdivision To Whom It May Concern: We respectfully request your review and approval to construct the subject septic system. Attached are: 1. A site plan with stamp and original signature of engineer. 2. Design and calculations with stamp and original signature of engineer. 3. Results of soils, percolation and water table test with stamp and original signature of engineer. An onsite sewer system is proposed for a new 5 -bedroom house. There are no existing onsite water or sewer systems located on adjacent lots or within 100 feet of the proposed system. The ground surface slopes across the lot from northwest to southeast, varying approximately to 4 to 6 percent. An existing natural slope of greater than 25 percent (avg. 2H to IV) is located on the east side of the lot, reference attached site plan. Onsite surface runoff is directed to the south and east. This drainage condition is to be maintained after construction is completed. An area of reserved space will be provided south of the proposed drain field for replacement or modification of the disposal field. The both the proposed and replacement drain field locations are placed on the lot based on MOA slope setback memorandum dated April 7, 2004, attached. No groundwater or bedrock was detected at the time of excavation on May 26, 2004 or on June 3, 2004. We do not anticipate any impacts to adjacent properties. Please note that a test hole and percolation test has not been performed for the alternate field site. We respectfully request that a conditional approval by the Municipality to begin construction of the subject system, provided that a test hole and percolation test is completed by the undersigned for the alternate field site and submitted to MOA for approval prior to construction of the proposed system. A test hole has also been excavated on Lot 4 to the north, as well as two other test holes for the subdivision within 75 feet, all of which have the same soil characteristics to Lot 4, reference attached test hole logs. Please call me at 694-2332 if you have any questions or need additional information. 599 /C/Z�/Zn /_ �& R6dney P. IC>Xnney, Jr., P.E. RODNEY P. KINNEY ASSOCIATES. INC. CONSULTING ENGINEERS Dela mnoannn Own. curt IOL -(W) w zisu woun "« lw? Ti+,g« a<wo r suP,o, Project- LD°T 9 p 6",-A- S Page. � oi_Iq ,cve a:&�et w,✓s+.� G 6 r y Job No., Date, By. �E C i 1 �'I \\tY=CO! O k CO I Z fn \ p / W � I u / o m pL t. I M 0O 1-- W -im�%/ o C M l l ney P. Kinney. Jr. C E195/ h o Q w , 9 ~' \ w ----- gOe k W I is°' ji w , 9 ~' \ w ----- gOe DATE: April 7, 2004 MUNICIPALITY OF ANCHORAGE Building Safety Division Il�ll�l�lf���✓/G,\I�I�idl� TO: On - Site Services Program FRI s oss, P.E. ��ktger, On -Site Water Wastewater Program SUBJ:' Slope setbacks from >25% z .1- i41 In situations where slope conditions will not allow a wastewater disposal field to be located 50 feet horizontally up gradient from a change in slope to greater than 25%, as required in AMC 15.65.060A.1.b the following requirements apply: (As allowed by AMC 15.65.030.G) 1. A point shall be determined two and one half feet above the invert of the distribution piping Df -the -septic -field atlhe field's.closest-point-tG4he-slepe-9reater than 25%. 2. A line shall be drawn from this point and perpendicular to the distribution piping at a down slope of 25% In the direction towards the slope greater than 25%. 3. The intersection of this hypothetical line and the actual slope shall be a minimum of 35 feet horizontally from the point established in #1. 4. This 35 foot horizontal separation shall be the minimum allowed between a disposal field and a slope of greater than 25%. If a property has a wastewater disposal system that was constructed prior to 1986 and the absorption field encroaches a change In slope greater than 25%, an upgrade of the failed system may be approved in the same location if the following applies: 1. No other location exists on the property to construct an upgrade drain field with proper separations. 2. The engineer field verifies that no effluent ever surfaced on the slope surface. 3. The engineer maximizes the separation from the field to the slope as much as possible. 7Ai24.r j"A"JAs Su60. RODNEY P. KINNEY ASSOCIATES, INC. Project. LOT 3 r /3u�X S Page. 3 of Iv CONSULTING [womaes 1tl1! mnonG.D DorlL sm 101 Q� i�iM>� w 1i= FALOUn n.-�wY Job No* �G�C >Lt tUysliV Date• S L8 Jy Tice• 5i -op By, A' i I I I I i ! I ! ! i � I 44 I I I I �\ ! � � v " 44 �oQv,v 7,4134L- RODNEY P. KINNEY ASSOCIATES, INC. Project. Gtr 30 j;caLk S Page. Y of 1`I CONSULTING ENG"WIMI MIS CDOONIRD a am 101 ^LA" ii � . F"410"M 100)dGr< �NlL� ✓IL✓ /o by Job NO.* Date* rue:�N[/�QL, E/� sYSTrnn �csln� ey. QK h� •• C'`lTt`i, 9 •,iron 0 Rodney P. Kinney: Jr. . �,• I I •, CE 95 •moi I I I 1�•° I I ' i I. • IF h ? �d••u a! � ! z �ti \ Z I ►. , ��ti�� I tZ �i, c II��Y io i o f v O v o V' M p g v � � •�+� eC ' y53So✓J .li , %A \41N 4N %Stl V h h s ;v c � ee • •s�Eis>�,fv/u s aeo, RODNEY P. KINNEY ASSOCIATES. INC. Project- Q�otx Page. S of fY CONSOLTINO EM0INCERS MIS Cilllael6e O.M sm 101 ll i RNa• .Iwau ren %Inl e R . �)/LL/ ✓i)� O Y n -(rT) r.-..., rA"Wy) r. SW Job No.* Date' Title- 6 itle 6 500 ZAs IL 2°10 7W M. 21 i ! NO Tc 5 I , 'tEVi+T/o�S ALL Z, Sr/vG -r*luc SIH�4u i4E ea4c=v 4Rr7)mt TnAN `out '4 � ?t.. Of. .. Sti ! ! i �� Radn Y P. Kinney.CE _ I �•� 95 70. I/ 6r�S7i.�•4 GRoa.un ! I I ! ! i I gem,") SSE i'a G' LO C.K--� I o N N �6,/louvo m I w�Y,G i I N fv)o cwc i i ! NO Tc 5 I , 'tEVi+T/o�S ALL Z, Sr/vG -r*luc SIH�4u i4E ea4c=v 4Rr7)mt TnAN `out 7A13 cC4AOJOS RODNEY P. KINNEY ASSOCIATES. INC. Project- 4-O 7— 3 iLOG,C S -Page* 6 of_q CONSULmOiion Dom am lot rw, u It Me" Job No., RD/�' SU tl)✓fW Date* G fltle/QE T/LFit)GN SEGTIoN — S� c��0� gy. RK F�iJ/IN bRADe' / /»ouN•�EO� T y� �— �}�• F,rE - 1 ECF—Dow/ .ry P WrDr TRFNG/� SEGTIoN - 5�� t✓i/�r i SCE %f TTi�Gh`G D T//REE T/tO ys — 2 - S6 /•✓ aTs+ c.V[rr1 i ow w �a /�� • M :Olney P. Kinney. Jr.. •v CE 193 : $moi Roger Sullivan Wide Drainfield Size Design 1 trench - 5 feet wide No. of Bedrooms: Perc Rate: Depth of Gravel Below Pipe Length Reduction Factor. Application Rate: Area per Bedroom: Trench Width Drain Field Length: Lot 3, Block 5, The Tablelands Subd. 5 beds 4 min./inch 48 fl 0.5 0.6 g.p.d./s.f. 150 s.f. 5 ft. 7 e,C ly �����• OF A14%%, * H *1 .. ...... ...... f,- Rodney P. Kinney, Jr. �lr'• CE795j S` A G/7 AVaS,= 150 sf/Bedroom X No. of Beds X Reduct. Fact. Application Rate Trench Width 125 ft. plus 10% = 137.5 ft. S!%E!�tIa 8 OF AI\�� W Municipality of Anchorage's - •s sE + Development Services Department 0 * : TH •••'• �� Building Safety Division � 2 1 On -Site Water and WastematerProgram /� • 4700 South Bragaw SL • • • • • . .... • .. P.O. Box 1966°.0 Andlomge.AK 95519-60:0 �r a,: Rod P. Kinney, Jr. car�% ...... Ci anc� hc2ce ak.us f • CEP955 (c07) 343-M �����Fo:� ��O i Soils Log - Percolation Test I ""ki"F ITSSW Performped For: f -"p 2t I S« I I 1 VA's __Da12 FeronnM:ti�oy _ Petr Legal Description: L04 3 IeGk S Township. Range. Sedcn: 'r I S IJ , (L I VV , set -3 Site Plan TP -IR Oepth o1LL-,AN10 4 fl51LT w MM GNnL� Te kcz op -G ANte-s SILY SAMD w1?N PPE' 5- ' &aAvfrL- 65M) 6- 7- 9- 0- 12- -7- 9- 0- WAS GROUND WATER ENCOUNT'RE07 t4ID _ s IF YESWatOtp 512.& 104 Depth toWater After p Monitoring? Out E 1�, b et1 ro c. L Date 41oy ) Reading Date Gross Time Net Time Depth to Water Net Drop S yT ,y -1;38:10 S.S63 8:08:10 00:30:00 7,H38 I.$7S 6:x1;7.0 o0:T0:o0 -7,438 1.8-1f 0 18'Y5.OS I 9:15:05 00:30:0 al I S•SG'S 7.501 1.938 15 15 Imx�rssrtl FERC !CLE CI:.I: icR PP.?I T:STRUNE_T:::ltl FAXD /7�FT KNI) WA%fL (eY CO1?1cNTS Ii9G,L 59Ai< aO112 PERFORMED BY: P-00�••��IAV 1 got-)140,lef CERTIFY THAT THIS TEST WAS PERFOR?.IED IN ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES C: EFFECT ON THIS CATE. DATE: L S%AA Steel Residential Septic Anchorage Tank& Steel Residential Septic Tanks Welding Inc. �oYae 2 SutJ�t V4 I.oT 3 --gS ,rt4-r 'j�At3L111 sb�1 DS 49415,90 Features: • Constructed to the requirements of the Uniform Plumbin�c Code. • Watertight manholes prevent seeping of groundwater. • Coated inside and out with coal tar pitch. • Custom tanks, including special interior and/or exterior coatings, are available. • Dimensions and weights are approximate. • Approved by the Municipality of Anchorage. Anchorage Approx. Steel Diam. Length Tank Model Gallons Gauge (inches) (feet) Number (feet) 5'-4" (A) (B) AT1000S 1,000 12 58 8 AT1250S 1,250 12 58 10 AT1250S10 1,250 10 58 10 AT1500S 1,500 12 58 12 AT1500S10 1,50 10 58 12 AT2000S 0 10 58 10'-8" AT2500S 2,500 3/16 64 17 AT3000S 3,000 3/16 76 15 AT3500S 3,500 3/16 76 16 AT4000S 4,000 3/16 76 18 Length Length Shipping Maximurr Compt.1 Compt.2 Weight Burial Dep, (C) (D) (LBS) (feet) 5'-4" 2'-8" 927 6.79 6'-8" T-4" 1,061 5.45 6'-8" 3'-4" 1,177 8.75 8'-0" 4'-0" 1,203 4.01 8'-0" 4'-0" 1,377 7.22 10'-8" 5'-4" 1,772 6.13 11'-4" 5'-8" 2,650 11.85 10'-0" 5'-0" 3,508 10'-8" 5'-4" 3,508 12'-0" 6'-0" 3,757 Back to Septic Sy_ptems_home_page. http://wwv.anchtank.conVSeptic_SystemsISteel_Residential_Septiclsteel_residential_septic.html 5/24/2002 Municipality of Anchorage Development Services Department ` Building Safety Division , On -Site Water and Wastewater Program • ' ' 4700 South Bragaw St. 46is „ , r P.O. Box 196650 Anchorage, AK 99519-6650 www.cl.anchorage.ak.us (907)343-7904 ON-SITE SEWER/WELL SUBMITTAL COMMENT SHEET To: Rod Kinney Legal description: The Tablelands block 5 Lot 3 The attached paperwork has been reviewed and is being returned for the following reasons: ❑ Original signature or stamp missing on ® Calculation error in design. P ❑ Additional soils information needed. ❑ Water monitoring results inadequate. ® Discrepancy in information submitted. Perk rate is 4 on work sheet and 15.5 on perk form ❑ Topographic information missing or inadequate. ® Incomplete; missing Proposed water line ® Incomplete; missing Total depth of trenches ❑ Additional adequacy test information needed. ❑ Water sample unacceptable. _ ❑ Measured/proposed distances/dimensions missing. ❑ Locations of all soils, percolation and water monitoring tests not shown. ❑ Proposed system too deep for soils information submitted. ❑ Well log required. ❑ Omission in narrative. _ ❑ Insufficient fill over tank or field._ ® Other. Identify slope setback to alternate site Name of reviewer: Jeff Date: 6-22-04 Please supply the necessary information and re -submit your request. LEAVE THIS FORM ATTACHED TO THE PAPERWORK