Loading...
HomeMy WebLinkAboutKENO HILLS #1 BLK 5 LT 1Keno Hills #1 Block 5 Lot 1 #020- 171 - 12 Municipality of Anchorage Development Services Department Building Safety Division On -Site Water & Wastewater Program, 4700 South Bragaw St. P.O. Box 196650 Anchorage, AK 99519-6650 www.ci.anchorage.ak.us (907) 343-7904 Page 1 of 3 On -Site Wastewater Disposal System and/or Well Inspection Report Permit Number: SW030017 PID Number: 020-171-12 NamesWastewater 'PEPPER'S CONSTRUCTION System: ■ New E] Upgrade Y Address: 10224 W. FRONTAGE ROAD * EAGLE RIVER, AK. 99577 ABSORPTION FIELD Phone: No. of Bedrooms: (907) 694-9681 4 []Deep Trench ❑ Shallow Trench ❑ Bed ❑Mound ■Other LEGAL DESCRIPTION Sail Rating: 6 DGPD/Sg. Total Depth from adgia2 grad.: MAX Ft Ft. Block: Lot: Subdivision: Depth to pipe bottom from original grade: Gravel depth beneath pipe: 5 1 KENO HILLS W1 SEE DWG. Ft. 0.5+ Ft. Township: Range: Section: Pit added above original grade: Gravel length: — — — SEE DWG. R. 40 n. Gravel width: - Number of lines: Dielonce beMeen lines: WELL: ■ New ❑ Upgrade 5 R. 1 — Ft, ClassYcaHon (Private, A.B.C): Total Depth: Cased Ta:IBEaROCK) Total absorption area: Pipe motedal: D 3034/ F-810 PRIVATE 300 Ft. 21 Ft. 200+ so. R Driller. Date Drilled: Static Water Level: Installer. GEG, Ltd. Dote installed: 3/7/2003 SULLIVAN WATER WELLS 3 11 03 12 Ft. Yield: Pump Set At: Casing Height Above Ground:TANK 2.5 cPM UNKNOWN Ft. 2 Ft. SEPARATION DISTANCES ❑ Septic ❑ Holding ❑ S.T.E.P. ■ other* To Septic Absorption Lift Holding Public/Pdvote Manufacturer. ORENCO SYSTEMS Capacity in gallons: 1500 From Tank Feld Station Tank Sewer Ones Well 100'+ 1 Oo'+ — — 25'+ Material: _ FIBERGLASS Number of comportments: 2 Surface Water 100'+ 100'+ — — — LIFT STATION Lot Line 5'+ 10'+ — - — Size in gallons: 1500 Manufacturer: ANCHORAGE TANK ORENCO SYSTEMS 'Pump on' level at: Pump off' level at: High water alarm at: Foundation 5'+ 10'+ — — — TIMER TIMER 46" 11 Pump Make k Model: Electrical Inspections "domed by: Curtain Drain NONE KNOWN #20 051 OS HHF M.O.A. BENCH MARK Remarks: Location and Description: *THIS IS AN ADVANTEX TREATMENT SYSTEM TOP OF MANHOLE LID Aosumed Ekvogon: 100.00 Ft. --REVISED EMBED q..JO4 ENGINEER'S S L 006>0� OF gab o� Inspections performed by: GEG, Ltd. Dates: 1st 3/7/2003 TM� ..... - ......... �.aO 2nd 3/7/2003 r .......` 3rd 5/13/2004 QO Je e A. r essr Development Services Department Approval � 0� s . -79.• foo 30�f�coo0 Reviewed and approved by: MW 17rvio Date: 0 /y (Rev. 12/01) �p0"PrafISSs;o�°o� 4OOD��p� i Jeri YoQ1, Mo/4, rlg5 CO/I'rl✓MPN 40.d C044'0115 Wert PERMIT NUMBER: AS—BUILT D RA T 1 I N G PARCEL ID NUMBER: SW030017 020-171-12 r,,,, ° ---------- A!// ----- 33' SECTION UNE EASEMENT / .:.-,•,�,.� . .f / -NEW WELL 1 ALTERNATE SITE �} \ II M72 2 I ¢� NEW DRAINFIELD---- I Mit "3 REVISED 11/19/041_,_ 1 19 04 GARNESS ENGINEERING GROUP, Ltd. -..--.. -. CONS€7LTANTS& GENERAL CONTRACTORS RAL PARED FOR: PHONE NU muL r�ac numocn: PEPPER'S CONSTRUCTION (907) 694-9681 2 OF 3 \L DESCRIPTION: KENO HILLS SUBDIVISION; LOT 1, BLOCK 15, OF WORK: AS -BUILT DRAWING OF NEW WELL LOCATION AND SEPTIC SYSTEM –NEW 1500 GALLON FIBERGLASS ADVANTEX TREATMENT SYSTEM %AM 51.49 31.36 54.50 41.46 82.01 63.53 79.75 61.68 54.71 160.55 55.87 1 70.62 X04 D . ...^. 5.: .. 951 .• a O PERMIT NUMBER: AS -BUILT DRAWING PARCEL ID NUMBER: SWO3O017 020-171-12 TOP OF ADVANTEX POD TOP OF MANHOLE _ 98.62 (AVG.) 100.00 (AVG.) FINAL GRADE = 96.07+ 2' INSULATION TOP OF TANK� II I 94.00 94.07 II TOP OF TANK INVERT OF PIPE = 93.11 - FILTER FABRIC 2' INSULATION - TOP OF SAND -� - 91.24 (AVG.) BOTTOM OF TRENCH = 88.74 (AVG.) - REVISED 11/19/ APPROVED 5'� GARNESS ENGINEERING GROUP, Ltd. CONSULTANTS & GENERAL CONTRACTORS 3701 E. ROAD, SUITE 101• ANCHORAGE, AK 99507 • PHONE (907)337-6179 ' FAX (907)330-3246 '.PREPARED FOR: - PHONE NUMBER: PEPPER'S CONSTRUCTION (907) 694-9681 LEGAL DESCRIPTION: KENO HILLS SUBDIVISION; LOT 1, BLOCK 5, TYPE OF WORK: PROFILE AS—BUILT DRAWING OF NEW SEPTIC SYSTEM ORIGINAL GRAI = 90.74 HIGH POINT INVERT OF PIPE = 91.90 (AVG.) RELATIVE ELEVATION OF BOTTOM OF TEST HOLE = 84.74 (TEST HOLE DRY) DATE: 000bpp 11/18/2004 0! of DRAWN BY: C.J.G. SCALE: �..••. f oI C 4 - N.T.S. . . ...... ........ PAGE NUMBER: 3 OF 3 :.. . IQ.. . ` . cc:... .0 Oct 24 05 06:08p From +19078308507 P. Scott Peppers Mon Oct 24 05:46:01 2005 907-694-9680 page 1 of 1 INSPECTION REPORT MUNICIPALITY OF ANCHORAGE, BUILDING SAFETY DIVISION 4700 SOUTH BRAGAW INSPECTION INFORMATION &HELP: S43-7882 X07 249-7777 www.muni.org/SSD/inspeotions.ufm INSPECTION: VOICE 343-8300 INSPECTION. FA ( ) - NAME: NG COMPANY: ACCESS ELECTRICAL PHONE#: 301-1646 PHONE#: ADDRESS: 17267 ASHLAND DR LOT 1 BLOCKS SUBDIVISION: KENO HILLS #1 COMMENTS or DIRECTIONS CALL 1 HR S4 FOR ONSITE MTG TYPE OF INSPECTION: Final Eleatrloal PERMIT #: 04-1256 INSPECT DATE: 10/24/2005 PHONE #: GRID C SW3438 COMMENTS: (FOR INSPECTOR USE ONLY) ��Eri�� i✓tKoM Io - I a - oS ! r.>� t��L--rf oc.1 ��(-ZK�c.-r�.[�, DATE: PRINTED NAME i -I!�' •�L ( �! . 10 O~ 04.: ~4p Peppers :' by DOC CO. dba 907-GS4-SGSO SULLIVAN' WATER. WELLS...:. P.O. B0X670272, CHUGIAK,. ALASKA 9.9567 · TELEPI:tONE688'2..7.5~.:' ' '. IWNER OF LAND: ,DDRESS: i ' . '...I .... '""' ': -"'" .-....-..,. :.,. , .................. ' .:", ............ ~ t~: f,,~. ~; ;:-7/ s we~'l~a~d~b.ap~ved permit'~cali~' ~s 'J No ._,. ..................... :--_~ , ~ethod of Drilling: :~{ota~, ~ cablgtool · .' )~pth of wel~; ~ ~ ~ ;asing Type ~ ~EE~ Wal. I T. bjckqes% ; ~ ~ D inches 1 ''-'. -'" ' · .' }iA~te~F{~'~'~ .'. ". in~h~'s,.depth .~"[,~' : fe~t.. · - ~ . ::' ' ...:; '... -. :iner~ype: "::~'~'"~' '"' :' -" " ;asing Stickup Above Ground: ~ ' feet 3tatic Water Level: /~' feet ~ecover Rate: ~ · ~ gpm Method of Testing: ~/~ ~ell Intake Opening Type: ~ o~n end ~hole , ..... ,.. b,., ,...,. ~, i.. , .~.:' J Scree~; -'.t' .-Start.- f~;.,: ..... ~t~ Stopp~fl-:~"..-.,:'... ;, ~t~tt ~ Perforations Sta~ fee .~)opped . feet Grout Type:~c~ I Volume / bo ~' Depth: [rom O feet, to ~O feet Well Disinf~t~ Upon Completion? ~s O No Method of Dis~nf~tion: ~au~,O~- b--O ~/~ ' BORE HOLE DATA DEPTH F~om To .2P~ p.1 ATTENTION: It is the responsibility.o~ the I~'l~'erty owner to submit a'c~by of'the well log tO the proper 'adtho¢ity.. Municipality of ~ch~age: :Deparlm~nt of H~hlth ~:'Hu~nan:Ser~Ices and/or Department of Environmental Conservatiom MatSi. l Borough: Departmer~t of Envi~:6nm'ental C6hservation. .' · ..' · ' '" ., .1 ..... ...'.. .!.... ~..;-..;: 'i".i':": :,-:...'":-..~-, .'. ':.,.~- '- ': '.,,: '" ....... ' .... ' "' ' '""':" "' : ' ' '" "'"'"" ..... ' " " ...... "'""'?'" '"" ' ' ' t..- :.. .:-..,.,~' "· '... '.', .~..'..,:, · . .' .... . ~.:,i,-.'".~, ' :" :'-' '-"'.'"., .' ' '.' .'..~: ".~:~": · :."J- '-., · ". , ,'.;." .. '.' '. ' . . . · , · . ~ .:...'. · ::-.-. .......' .... ...,..:;,.'.. ..,:..:, .,, . ~'..~.,...,.,,... ;~:'f.: .o,' ;.,.'.;~,~,. ..,.:.. - .. · >' .... ~ . .., · ~.....',.:~..:.. .; ' ,;.;:,..~ ,' .:~'t~:-~'>>,..:4 .-',~ '.',. :.?: ,',r:' ..',C · :%' ..:'~,.,..'. ':: ." .~...; · ....,. ..,.. :..:. .'11~:... '...: '. . . . · .. . . ~ . ..- .... · . --.'/..' . -.. ,.._g_.._ ... ~ ,....._ MUNICIPALITY OF ANCHORA GE Development Services Department On-Site Water & WaStewater Program 4700 South Bragaw Street P.O. Box 196650, Anchorage, AK 99519-6650 (907) 343-7904 t/ 12. '3 ON-SITE WASTEWATER DISPOSAL SYSTEM I WATER SUPPLY PERMIT Initial Date Issued: Feb 06, 2003 Expiration Date: Feb 06, 2004 Permit Number: SW030017 [ L-e'~l ~D~'~C?ilSt i~':-.~iK E N O: ~I!;I~-~I.~LK ~.~5.'LT._-.'~I i~ Design Engineer: 0041 AK Water & Wastewater Consultan' Owner Name: Scott Peppers Owner Address: 10224 West Frontage Road Eagle River, AK 99577- Parcel ID: 020-171-12 Site Address: 017267 ASHLAND DR Lot Size: 128502 SQ. FT. Total Bedrooms: 4 Permit Bedrooms: 4 This permit is for the construction of: r~ Disposal Field r~ septic Tank Holding Tank [--] Privy [] Private Well [] Water Storage All construction must be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal Code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations ( 18AAC72 ) and Drinking Water Regulations ( 18AAC80 ). 3.. The engineer must notify DSD at least 2 hours prior to each inspection. Provide notification by calling (907) 343-7904 ( 24 hours ). ( Not required for a Water Supply Permit only ). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must be either: A. Open and closed on the same day. B. Covered, sealed, and heated to prevent freezing. Received By: Issued By: Date: ~ Date: ~___~~,~ ALASKA WATER & WASTEWATER errs„=ramm.«m�sn++a:ama esaa..ae CONSULTANTS, INC.m” January 3, 2003 Municipality of Anchorage Development Service Department Building Safety Division On -Site Water & Wastewater Program 4700 South Bragaw Street P.O. Box 196650 Anchorage, AK 99519-6650 Ref: Proposed Well Septic System for Lot 1, Block 5; Keno Hills Subdivision ADVANTEX' TREATMENT SYSTEM To whom it may concern: 1. GENERAL: The proposed 4 bedroom Home will be served by a private well and septic system. Two test holes were excavated on the property. We are proposing to design the septic system around the 30 foot radii of these test holes. Due to the shallow bedrock and the desire to minimize the size of the drainfield area we are proposing to use an Advantex treatment system and a 5 -wide trench type drainfield. The well is to be located in the area shown on the site plan and design drawing. 2. SOILS: See the attached log, which shows the soil classifications, groundwater monitoring, and the percolation test results. 3. DRAINFIELD APPLICATION RATE: The intent is to install an Advantex Treatment System that will allow the use of a small drainfield in the area around the 30 foot radii of the test holes. A percolation test was perfonned in each test hole between the depths of 2.0 to 2.5 feet. and found the rates were both <1 minute/inch. The Advantex system has received class III approval and we are going to conservatively assume an application rate of 3.0 GPD/FT2. 4. TRENCH DESIGN: a. Percolation Rate: <1 minutes/inch b. Proposed Application Rate: 3.0 gallons/day/ft2 c. Number of Bedrooms: 4 d. Design Flow: 600 gallons per day e. Minimum Absorption Area: 200 ft' f. Total Depth: 2.0 feet (max.) g. M.O.A. Approved Sand Filter Depth: 2.5+ feet It. Effective Depth: 0.5 feet 6901 Debarr Road, Suite 2B — Anchoraee, AK 99504 —Ph: (907)337-6179 —Fax: (907)338-3246 i. Width: 5 feet j. Minimum Length: 40 feet long k. Effective absorption area: 200 ftZ 5. ORENCO PACKAGE SYSTEM: The STEP tank with the Advantex Treatment System will be manufactured by Anchorage Tank & Welding to meet the latest design criteria established by Orenco Systems, Inc. The point of contact at Anchorage Tank is Lowell McNutt. As with their standard STEP tank, it is equipped with a high water alarm per M.O.A requirements. 6. SURFACE WATER: There is a drainage easement 100+ feet south of the proposed drainfield: In short there are no concerns. 7. TOPOGRAPHY: The average topography around the proposed drainfield range from 10%- 15% slopes. In short there are no slope concerns. 8. CLOSING: - I am open to any suggestions from your department that would be an improvement to the proposed system. I am unaware of any negative impacts that this installation would impose on adjacent wells, or septic systems. If you have any questions, please call us at ZI�n .E., M.S. NOTE: Attached is a site plan drawing, a topography drawing, a design drawing, an Advantex detail, a trench detail, two soil logs, and a 7 page construction specification letter which are all part of the design package for this septic system. 6901 Debarr Road, Suite 2B —Anchorage, AK 99504 — Ph: (907)337-6179 —Fax: (907)338-3246 LOT 7:' ASHLAND S/D i y /rte TRACT A; ASHLAND S/D ' 'SF,PTIC'JJ%a LOT 2; ASHLAND S/D// �J/ > ....... THpl, klt3 PROPOSED WELL \ t TH#2 PROPOSED 4 BEDROOM HOUSE LOT 5, BLOCK 4; �� _ PROPOSED SEPTIC SYSTEM (SEE DESIGN, PAGE 2 OF 4) I `I 1 KENO HILLS S/D \�G II I1 + — ----------------------------- ---I 1 j IVI ----------� / \ I 1 1 V 1 +00WFII RArnus I V I I I LOT 2, BLOCK 5; I I 1 I 1 V + KENO HILLS S/D I ( !! NO ENCROACHMENT CONCERNS \ I J LOT 6, BLOCK 4; � I ! I 1 KENO HILLS S/D I I I Q 1 1 1 DATE: 1/3/2003 - .).. .. .. .• .... '^ ...... .. DRAWN BY: Z.T.G. ALASKA WATER & WASTEWATER CONSULTANTS, INC. SCALE: - - 1 — 100, 6901 DEBARR ROAD, SUITE 28' ANCHORAGE. AK 99506' PHONE (907)337-6179' FAX (907)338-321,6 r/ i^ PREPARED FOR PHONE NUMBER: PAGE NUMBER: SCOTT PEPPER 694-9681 1 OF 4• /, ft ey A. Go �Ijn 9, C 7953 IiI" LEGAL DESCRIPTION: KENO HILLS SUBDIVISION; LOT 1, BLOCK 5 `P +�"tlprofession°<'� TYPE OF WORK: PROPOSED WELL AND SEPTIC LOCATION LZ _1_1_.Z_1_ -Z-1— L1_G1� ALTERNATE FrA I�1�11i#1 ' STALL DOUBLE CLEKNOUTs—( r0 I PROPOSED 4 BEDROOM HOUSE i f' SECTION LINE EASEMENT \ PROPOSED WELL \\ I / �O- S / FOUNDATION PROPOS D 1500 GALLON ADVANTEX TREATMENT SYSTEM (SEE DETAIL PAGE 3 OF 4) -PROPOSED DRAINFIELD. EXCAVATE A TRENCH THAT IS 2 FEET DEEPMAXIMUMBY 5 FEET WIDE BY 40 FEET LONG. ADD 2.5 TO 3.0 FEET OF M.OA. APPROVED FILTER SAND AND THEN ADD 0.5 FEET OF CLEAN, WASHED SEWER DRAINROCK. (SEE DETAIL PAGE 4 OF 4). NOTE: THE CONTRACTOR SHALL HAVE THE SECTION LINE EASEMENT AND THE CREEK SETBACK FLAGGED BY A REGISTERED LAND SURVEYOR_ PRIOR TO CONSTRUCTION. ----------------- 10' UTILITY EASMENT — -- — — -- 1/3/2003 DRAWN BY: o �� ..........s°a ALASKA WATER & WASTEWATER Z.T.G. CONSULTANTS, INC. «-_�=— scA�E` 50' ........ .. ... ............ _ 6901 pE84RR R04D. SUITE 2B ' ANCHORAGE AK 99504' PHONE (90])33]-61]9' FAX (907)338-3246 _ PREPARED FOR: PHONE NUMBER: PAGE NUMBER: p SCOTT PEPPER (907) 694-9681 2 OF 4�' �p J r Garn ss: LEGAL DESCRIPTION: O o _ �G KENO HILLS SUBDIVISION•' LOT 1' BLOCK 5 TYPE OF WORK: _ °�4P f'40fessloY�Q�� DESIGN OF PROPOSED WELL LOCATION AND SEPTIC SYSTEM �04p0000� INLET _ FINAL 6" ABS F 6" ADS GLUED 30 INCH 6" JIM CAP/—ADVANrEX INSULATED fFYP.2)—\ . / AX20 PDD RISER �pg�p EWEK rp✓)@+ .RSOCK. INLET _ Advan.Tex" _Treatment System n. PE%AS THEOSS, NOTE. THE BOARD BE INSTALLED OVER THE SEPTICIOTANK do 4" AX20 - Mode la c ADVANTIX MANUAL BEYOND ON ALL SIDES EXCEPT UNDER THE AFILTER. THIS WILL ALLOW 40x94Pod Or�o�Byslemsf _ Ll FOR HEAT T TO ESCAPE FROM TANK & RISE TO THE FILTER ABOVE IT. INLET _ FINAL 6" ABS F 6" ADS GLUED 30 INCH 6" JIM CAP/—ADVANrEX INSULATED fFYP.2)—\ . / AX20 PDD RISER DATE: 1/3/2003 DRAWN BY: ALASKA WATER & WASTEWATER Z.T.G. CONSULTANTS, INC, SCALE` 6901 DEBARR ROAD. SUITE 29 . ANCHORAGE. AK 99506' PHONE (901)33) 6119 ` FAX (901)33832L6 N.T.S. PREPARED FOR. PHONE NUMBER: PAGE NUMBER: SCOTT PEPPER (907) 694-9681 1 3 OF 4 LEGAL DESCRIPTION: KENO HILLS SUBDIVISION; LOT 1, BLOCK 5 TYPE OF WORK: DETAIL OF ADVANTEX TREATMENT SYSTEM BIOTUBE - SCREENED VAULT EFFLUENT PUMP 9500 GALU FIBERGLASS UFTSTATION a TH ''7."Q `-�y . arne s:'� IO sf 79 a 0 404eC F'rOfes5i0X` - oDODOOoo� �pg�p EWEK rp✓)@+ .RSOCK. INLET _ OPTIONAL SUDE SECTION OF 8" PIPE OVER THIS CONNECTION TO PROVIDE Ll '. SHEER PROTECTION— ' EXTEtJD TO BRIDGE EXCAVATION DATE: 1/3/2003 DRAWN BY: ALASKA WATER & WASTEWATER Z.T.G. CONSULTANTS, INC, SCALE` 6901 DEBARR ROAD. SUITE 29 . ANCHORAGE. AK 99506' PHONE (901)33) 6119 ` FAX (901)33832L6 N.T.S. PREPARED FOR. PHONE NUMBER: PAGE NUMBER: SCOTT PEPPER (907) 694-9681 1 3 OF 4 LEGAL DESCRIPTION: KENO HILLS SUBDIVISION; LOT 1, BLOCK 5 TYPE OF WORK: DETAIL OF ADVANTEX TREATMENT SYSTEM BIOTUBE - SCREENED VAULT EFFLUENT PUMP 9500 GALU FIBERGLASS UFTSTATION a TH ''7."Q `-�y . arne s:'� IO sf 79 a 0 404eC F'rOfes5i0X` - oDODOOoo� I( I. . 0 I ' MT -FROM ADVANTEX TREATMENT SYSTEM 1 -------==------ -------------1 I I I CO I O I ------------------------------J MT -40 FEET LONG. - - 03 MIM JAR FILTER FABRIC FINAL GRADE INSTALL BRACING AND INSULATION - STAKING AS NEEDED T �5 FEET ALASKA WATER R WASTEWATER CONSULTANTS, INC.,­­l=s " - 6901 DEBARR ROAD, SUI TE 29 •ANCHORAGE. AK 99506 • PHONE (907)53]-6179 - FAX (907)339-3266 PREPARED FOR: PHONE NUMBER: SCOTT PEPPER (907) 694-9681 LEGAL DESCRIPTION: KENO HILLS SUBDIVISION; LOT 1, BLOCK 5 TYPE OF WORK: DETAIL OF PROPOSED DRAINFIELD ADD 0.5 FEET OF EFFECTIVE ADD 2.5 TO 3.0 FEET OF FILTER FEET DEEP MAXIMUM J BY: Tj .z.T.c.O�1gN.T.S.NUMBER: p4 OF 4P. ffP. A. (i lI1 P.SR ALASKA WATER & WASTEWATER — - CONSULTANTS.JNC. _ •__-- .:-x�= SOIL LOG - PERCOLATION TESTI . LEGAL DESCRIPTION: KENO HILLS SUBDIVISION; LOT 1, BLOCK 5 PERFORMED FOR: SCOTT PEPPER DATE: 10/2/2000 DEP_ Z_ (feet==== =E ORGANICS TEST HOLE #1. 7 BEDROCK B.O.H. 8 9- 10- 11 1011 12 13 14 16- 17- 18— I GROUNDWATOER I DATE ------------------------------------ ---------- q�-- / PROPOSED WELL '\ -- ----=--=----�- ----- --- ---------------- TH#1 ♦1 1 / ____ TH#2 * / PROPOSED 4 BEDROOM HOUSE \------- _____ SITE PLAN _ 1"=1D0' DATE READING CLOCK TIME NET TIME (MINUTES) CLASSIFICATIONS NET DROP (INCHES) rrSOIL yr GW O. ■GP ML M --PS FPSZ II�(1T�11 GM CIL �P.�ER r r G�/.moi.GC OL ZOOQ e50RgE0 P SWSM l�CH ,0 r r �y16 'SiYSt7i � f1114�!SC 7 BEDROCK B.O.H. 8 9- 10- 11 1011 12 13 14 16- 17- 18— I GROUNDWATOER I DATE ------------------------------------ ---------- q�-- / PROPOSED WELL '\ -- ----=--=----�- ----- --- ---------------- TH#1 ♦1 1 / ____ TH#2 * / PROPOSED 4 BEDROOM HOUSE \------- _____ SITE PLAN _ 1"=1D0' DATE READING CLOCK TIME NET TIME (MINUTES) WATER LEVEL READING NET DROP (INCHES) PQ�ED --PS FPSZ �P.�ER --- ZOOQ e50RgE0 P ,0 2 19 PERCOLATION RATE <1 (MIN./INCH) PERC. HOLE DIA. 6 (INCHES) TEST RUN BETWEEN 2.0 FT. AND 2.5 FT. 20 A FOUR HOUR PRESOAK WAS PERFORMED: ❑ YES ® NO SOILS LOGGED BY: JEFF GARNESS PERCOLATION TEST PERFORMED BY: SUSAN OSWALT COMMENTS: PERFORMED BY AKWWC, INC. I, JEFFREY A. GARNESS, CERTIFY THAT THIS VpS ERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE: I7 ALASKA WATER & WASTEWATER CONSULTANTS, INC - 3901 OEBARR ROAG, SURE 28 c ANCHORAGE. M. 99504 • PHONE (907)337-6179 • FA%:907 336-3246 •`WEBSRE: ak...com SOIL LOG — PERCOLATION TEST LEGAL DESCRIPTION: KENO HILLS SUBDIVISION; LOT 1, BLOCK 5 PERFORMED FOR; SCOTT PEPPER DATE: 10/2/2000 DEPTH (feet) ORGANICS ITEST. HOLE #21 1 SOIL CLASSIFICATIONS 2 GW ORG GM GM.' CL 4 GC OL ism SW MH 5 SP CH ; OH . 6 SC BEDROCK 7 8 9 10 11 12- 13. 14- 15- 16- 17- 18 - DEPTH TO GROUNDWATER DATE DRY' 10/2/00 DRY 10/11/00 DATE READING CLOCK TIME NET TIME (MINUTES) WATER LEVEL READING NET DROP (INCHES) RgF,� 2000 Pg50 . 1� 2 19� PERCOLATION RATE <1 (MIN./INCH) PERC. HOLE DIA. 6 (INCHES) TEST RUN BETWEEN 2.0 FT. AND 2.5 FT. 20 A FOUR HOUR PRESOAK WAS PERFORMED: ❑ YES ®NO SOILS LOGGED BY: JEFF GARNESS PERCOLATION TEST PERFORMED BY: SUSAN OSWALT PERFORMED BY AKWWC, INC. I, JEFFREY A. GARNESS, CERTIFY THAT THIS WASI PERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE: Contit'4ibrn5 have, beer "ref. I' Municipality of Anchorage Development Services Department Building Safety Division On -Site Water & Wastewater Program 4700 South Bragaw St. P.O. Box 196650 Anchorage, AK 99519-6650 www.cl.anchorage.ak.us (907)343-7904 CERTIFICATE OF HEALTH AUTHORITY APPROVAL FOR A SINGLE FAMILY DWELLING Parcell.D. 020-171-12 HAA# d�Fq 1. GENERAL INFORMATION Expiration Date:—L — 3 i —o6 Complete legal description KENO HILLS SUBDIVISION #1; LOT 1, BLOCK 5, Location (site address or directions) 17267 ASHLAND DRIVE * ANCHORAGE. AK 99516 Current Property owner(s) Mailing address Lending agency Mailing address Real Estate Agent Mailing address ROBERT & VICKI LUNDGREM Day phone 694-9681 5706 FLAGSTONE CIRCLE * ANCHORAGE, AK 99502 Unless otherwise requested, HAA will be held by DSD for pickup. 2. NUMBER OF BEDROOMS: 4 Day phone Day phone 3. TYPE OF WATER SUPPLY: TYPE OF WASTEWATER DISPOSAL: Individual Well Individual On-site 0 Individual Water Storage ❑ Individual Holding tank ❑ Community Class Well ❑ Community On-site ❑ Public Water System ❑ Public Sewer ❑ The Municipality of Anchorage Development Services Department (DSD) Issues Certificates of Health Authority Approval (HAA) based only upon the representations given in paragraph 4 by an independent professional civil engineer registered in the State of Alaska. Certificates of Health Authority Approval are required for the transfer of title (except between spouses) for properties served by a single-family on-site wastewater disposal and/or water supply system. DSD also issues HAAs upon request to homeowners. Certificates of Health Authority Approval are valid for 90 days from the date of issue for properties served by a private or Class C well and may be reissued with new water samples. (Certificates may be reissued for a period of up to one year with valid water samples.) Certificates are valid for one year for properties served by Class A or B wells or a public water system. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. 4. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based on procedures outlined in the Health Authority Approval Guidelines for this application, shows that the on-site water supply and/or wastewater disposal system is(are) safe, functional and adequate for the number of bedrooms and type of structure indicated herein, i further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation. Name of Firm GARNESS ENGINEERING GROUP, Ltd. Address 3701 E. TUDOR ROAD, SUITE 101 * ANCHORAGE, AK 99507 Engineer's Printed Name JEFFREY A. GARNESS, P. Engineer's Comments: In conducting this evaluation, GEG, Ltd. attempted to provide a thorough, conscientious engineering analysis of the system in accordance with ADEC and MOA DSD Guidelines & Regulations. The reported results described the performance of the system under the conditions encountered at the time of the test, and separation distances measured to readily identifiable features. The operational life of all wells and septic systems depend on the local soils condition, groundwater levels that may fluctuate during the year, and the water usage of the family being served by the system_ These conditions are outside the control of the evaluator of the system. Satisfactory test results do not guarantee future performance of the system, nor do they guarantee that there are no hidden defects or encroachments. GEG, Ltd. can therefore not provide any warranty or future estimate of how long the system will continue to meet the operational requirements of the ADEC or MOA DSD. The content of this report is for the sole benefit of the owner listad above. AnyjptLmj2e upon or use of tblsrspert-ley-a[ry Phone 337-6179 Date f° — oc P .Je C )'A, -Beefiness: CE -7953 0� c Oils',.%z����Ao otherperson orparty t authorized,il�ill it confer afiYlqrt whatsoever. I V SD SIGNATURE Mai ha3 co��y QOM i{)qi ih� Co i�t'an5 X Approved for oedrooms. 'lI av- BMW I0/Z/5 es beef) I'r'le � Conditional approval for bedrooms, with stipulations: Attachments: Chtecklist Maintenance Agreements J�0NT SENA Septic System Advisory Supplemental Engineer's Report Well Flow Advisory Other By. Original Certificate Date: (Rev. 12101) Municipality of Anchorage • '"` Development Services Department Building Safety Division On -Site Water & Wastewater Program 4700 South Bragaw St. P.O. Box 196650 Anchorage, AK 99519-6650 www.ei.anchorage.ak.us (907)343-7904 HEALTH AUTHORITY APPROVAL CHECKLIST Legal Description: KENO HILLS SUBDIVISION #1; LOT 1, BLOCK 5 Parcel ID: 020-171-12 A. WELL DATA *CASED TO BEDROCK Well type PRIVATE If A, B, or C provide PWSID# N A Well Log (Y/N) Date completed 3/11/2003 Sanitary seal (Y/N) YES Total depth 300 ft. Cased to *21 ft. FROM WELL LOG Date of test 3/11/2003 Static water level 12 Well production 2.5 WATER SAMPLE RESULTS: YES Wires properly protected (Y/N) YES Casing height (above ground) 18 in. AT INSPECTION 10/21/2005 34" BTOC ft, 3.9 g.p.m. Coliform 0 colonies/100 ml. Nitrate 0.613 mg./L. Other bacteria 6 colonies/100 ml. Arsenic: N/A mg./L. Date of sample: 10/14/05 Collected by: GEG, Ltd. B. SEPTIC/HOLDING TANK DATA Tank Type/Material ADVANTEX/FIBERGLASS Date installed 3/7/2003 Tank size 1500 gal. Number of Compartments E Foundation cleanout (Y/N) YES Depression over tank (Y/N) NO Date of pumping NEW C. ABSORPTION FIELD DATA "BELOW FINAL GRADE Date installed 3/7/2003 Soil rating Oid. r ft2/bdrm) 6_0 Cleanouts (YIN) YES High water alarm (Y/N) YES System type SHALLOW TRENCH Length 40 ft. Width 5 ft. Gravel below pipe 0.5+ ft. Total depth 6.58/5.08 ft. Eff. absorption area 200 ft2 Monitoring tube YES Depression over field NO Date of adequacy test NEW SYSTEM Results (Pass/Fail) For_�db werrts Fluid depth in absorption field before test _ in. Water Elapsed Time: _ min. in. Absorption rate >= New depth _in. treatment (past 12 mo.) (Y/N & type) If yes, give date ... D. LIFT STATION Date installed 3/7/2003 Size in gallons 1500 Manhole/Access (YIN) YES "Pump on" level at TIMER in. "Pump off' level atTIMERin. High water alarm level at 46" in. Datum BOTTOM OF TANK Cycles tested NEW Meets alarm & circuit requirements? YES E. SEPARATION DISTANCES SEPARATION DISTANCES FROM WELL ON LOT TO: Septic tank/lift station on lot 100'+ On adjacent lots 100'+ Absorption field on lot 100'+ On adjacent lots 100'+ Public sewer main N/A Public sewer manhole/cleanout N/A Sewer/septic service line 25'+ Holding tank N/A SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK ON LOT TO: Building foundation 5'+ Property line 5'+ Absorption field 5'+ Water main N/A Water service line 10'+ Surface water 100'+ Wells on adjacent lots 100'+ SEPARATION DISTANCE FROM ABSORPTION FIELD ON LOT TO: Property line 10'+ Building foundation 10'+ Water main N/A Water service line 10'+ Surface water 100'+ Driveway, parking/vehicle storage 10'+ Curtain drain NONE KNOWN Wells on adjacent lots 100'+ F. COMMENTS G. ENGINEER'S CERTIFICATION p•v. r 'I I certify that l have determined through field inspections and Q e ,4 T'•� review of Municipal records that the above systems are in conformance with MOA HAA guidelines in effect on this date. Engineer's Printed Name JEFFREY A. GARNESS 11009 E - Date z�62 ja e^e t0 S �n Prni HAA Fee $ C) Date of Payment Receipt Number (Rev. 12101) Waiver Fee $ Date of Receipt Number ADVANCED WASTEWATER TREATMENT SYSTEM MAINTENANCE AND REPAIR AGREEMENT MEMORANDUM OF UNDERSTANDING BETWEEN -MUNICIPALITY OF ANCHORAGE AND THIS MEMORANDUM OF UNDERSTANDING made and entered into as of this -> day of ( �' � )t ,t of 20(. j by and herein the "OWNER," and the Municipality of Anchorage, herein the "MUNICIPALITY." In consideration of the mutual covenants contained herein, the parties to this Memorandum of Understanding agree as follows: 1. ADVANCED WASTEWATER TREATMENT SYSTEMS. Municipality grants permission to Owner to utilize and operate an Advanced Wastewater Treatment System (AWWTS), described as located III - at Il <t1r�t i� ti�S ' 1 f t t< Anchorage, Alaska. 2. Definitions. A. Alteration. Any change to the design or function of an AWWTS that includes the installation or removal of any parts, components or pieces not included in the original construction permit and design. Prior to performing any alterations to an AWWTS the owner must obtain a Wastewater Disposal System Construction Permit from the Municipality pursuant to Anchorage Municipal Code (hereinafter, "AMC") 15.65. B. Certificate of On -Site Systems Approval. An approval by the Municipality of existing water and wastewater disposal systems given at the time of property sale and title transfer in accordance with AMC 15.65. The term begins on the date of approval by the Municipality of the installed system and shall continue while the AWWTS system is in use or operational or until the property is sold or title is transferred by owner and a new certificate of On -Site approval is issued to the new owner or transferee of the property. 5. Alterations, Installation and Removal of Additional Equipment. Owner agrees not to make any alterations, removal of parts or additions to the AWWTS without a Construction Permit from the Municipality. 6. Maintenance and Repairs. A. Throughout the term of this Memorandum of Understanding, the Owner shall maintain AWWTS in good repair. In addition, it shall be the responsibility of the Owner during the term of this Memorandum of Understanding, and any extensions or renewals thereof, at the owner's sole expense, to pay for any and all: (1) repair(s), (2) maintenance, (3) adjustment(s), (4) replacement costs, and (5) inspection costs. Further, Owner agrees to comply will all applicable ordinance, laws, regulations, rules and orders for the AWWTS. B. Omer agrees to provide the Municipality a written schedule of routine maintenance and repairs which have been performed on the system pursuant to the terms and conditions contained in the Owner's AWWTS Operating Permit. This schedule shall be submitted to the Municipality annually upon the renewal of the permit. The schedule of maintenance and repair contained in the Owner's AWWTS Operating Permit is: 1 :-i i,ti. C. Owner acknowledges that the fine schedule for failing to maintain and repair an AWWTS are codified in AMC 14.60. Owner: Anchorage: Purchasing Officer C. Any attempt to amend, modify, or change this contract by either an unauthorized representative or unauthorized means shall be void. 9. Jurisdiction: Choice of Law. Any civil action arising from this Memorandum of Understanding shall be brought in the Superior Court for the Third Judicial District of the State of Alaska at Anchorage. The laws of the State of Alaska shall govern the rights and obligations of the parties under this Memorandum of Understanding. 10. Severability. Any provisions of this Memorandum of Understanding decreed invalid by a court of competent jurisdiction shall not invalidate the remaining provisions of the Memorandum of Understanding. OWNER: By.. c „ Date: MUNICIPALITY: By: Title: Date: STATE OF ALASKA ) ) ss. TI3IRD JUDICIAL DISTRICT ) f: The foregoing instrument was acknowledged before me this day of 20 ,rh b}% ! '` Z l tir. i '7 the of on behal of the Municipality of Anchorage. NO ARY PUBLIC FOq ALASKA < My Commission expires: /jy` Municipality of Anchorage Development Services Department Building Safety Division On -Site Water & Wastewater Program 4700 South Bragaw St. P.O. Box 196650 Anchorage, AK 99519-6650 a www.ci.anchorage.ak.us (907)343-7904 Lsn CD�!>oNA-t_ 4-&A CERTIFICATE OF HEALTH AUTHORITY APPROVAL FOR A SINGLE FAMILY DWELLING Ar Parcel I.D. 020-171-12 HAA# `V 1. GENERAL INFORMATION Expiration Date: /7 r d Complete legal description KENO HILLS SUBDIVISION #1; LOT 1, BLOCK 5 Location (site address or directions) 1.7267 ASHLAND DRIVE * ANCHORAGE, AK 99516 Current Property owner(s) Mailing address Lending agency Mailing address Real Estate Agent Mailing address GEORGE STECKO Day phone 349-1183 2406 FANTAIL CIRCLE * ANCHORAGE, AK 99515 Unless otherwise requested, HAA will be held by DSD for pickup. 2. NUMBER OF BEDROOMS: 4 3. TYPE OF WATER SUPPLY: Individual Well E Individual Water Storage ❑ Community Class Well ❑ Public Water System ❑ Day phone Day phone TYPE OF WASTEWATER DISPOSAL: Individual On-site E Individual Holding tank ❑ Community On-site ❑ Public Sewer ❑ The Municipality of Anchorage Development Services Department (DSD) Issues Certificates of Health Authority Approval (HAA) based only upon the representations given in paragraph 4 by an independent professional civil engineer registered in the State of Alaska. Certificates of Health Authority Approval are required for the transfer of title (except between spouses) for properties served by a single-family on-site wastewater disposal and/or water supply system. DSD also issues HAAs upon request to homeowners. Certificates of Health Authority Approval are valid for 90 days from the date of issue for properties served by a private or Class C well and may be reissued with new water samples. (Certificates may be reissued for a period of up to one year with valid water samples.) Certificates are valid for one year for properties served by Class A or B wells or a public water system. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. 4. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, i verify that my investigation, based on procedures outlined in the Health Authority Approval Guidelines for this application, shows that the on-site water supply and/or wastewater disposal system is(are) safe, functional and adequate for the number of bedrooms and type of structure indicated herein. 1 further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation. Name of Firm GARNESS ENGINEERING GROUP, Ltd. Phone Address 3701 E. TUDOR ROAD, SUITE 101 * ANCHORAGE, AK 99507 Engineer's Printed Name JEFFREY A. GARNESS, P.E. Engineer's Comments: In conducting this evaluation, GEG, Ltd. attempted to provide a thorough, conscientious engineering analysis of the system in accordance with ADEC and MOA DSD Guidelines & Regulations. The reported results described the performance of the system under the conditions encountered at the time of the test, and separation distances measured to readily identifiable features. The operational life of all wells and septic systems depend on the local soils condition, groundwater levels that may fluctuate during the year, and the water usage of the family being served by the system. These conditions are outside the control of the evaluator of the system. Satisfactory test results do not guarantee future performance of the system, nor do they guarantee that there are no hidden defects or encroachments. GEG, Ltd. can therefore not provide any warranty or future estimate of how long the system will continue to meet the operational requirements of the ADEC or MOA DSD. The content of this report is for the sole benefit of the owner listed above. Any reliance upon or use of this report by any other person or party is not authorized, nor will it confer any legal right whatsoever. 5. DSD SIGNATURE Approved for bedrooms. Disapproved. 337-6179 Date 5-f 7 X Conditional approval for 4 bedrooms, with the fllowing stipulations: At the time of title transfer the new property owner Shad sign the nttacbed Maintenance Agreement which shall he returned t -n chis office befeae -- unconditional approval iq jcc,pciMen n f A r• i be 'ns1=911ed, well wires properly protected and add•rinnal f.31 $laee4 ever s3staeme Attachments: HAA Checklist ✓ Septic System Advisory Well Flow Advisory Manitenance Agreements Supplemental Engineer's Reort Other BOriginal Certificate Date: (Rev. 1MI) Municipality of Anchorage • Development Services Department Building Safety Division On -Site Water & Wastewater Program 4700 South Bragaw St. P.O. Box 196650 Anchorage, AK 99519-6650 www.ci.anchorage.ak.us (907)343-7904 HEALTH AUTHORITY APPROVAL CHECKLIST Legal Description: KENO HILLS SUBDIVISION #1; LOT 1 A. WELL DATA *CASED TO BEDROCK Well type PRIVATE If A, B, or C provide PWSID# N/A Date completed 3/11/2003 Sanitary seal (Y/N) YES Total depth 300 ft. Cased to *21 ft. FROM WELL LOG Date of test 3/11/2003 Static water level 12 Well production 2.5 WATER SAMPLE RESULTS: Coliform 0 colonies/100 ml. Nitrate 0.01 mg./L. Parcel ID: 020-171-12 Well Log (Y/N) YES Wires properly protected (Y/N) ***NO Casing height (above ground) 24 in. AT INSPECTION g.p.m. Other bacteria 0 colonies/100 ml. Arsenic: N/A mg./L. Date of sample: N/A Collected by: GEG, Ltd. B. SEPTIC/HOLDING TANK DATA Tank Type/Material ADVANTEX/FIBERGLASS Date installed 3/7/2003 Tank size 1500 gal. Number of Compartments E Foundation cleanout (Y/N)***NO Depression over tank (Y/N) NO Date of pumping NEW Pumper C. ABSORPTION FIELD DATA BELOW EXISTING GRAC Date installed 3/7/2003 Soil rating 02> ft%drm) 6.0 Cleanouts (Y/N) High water alarm (Y/N) YES System type 5—WIDE TRENCH Length 40 ft. Width 5 ft. Gravel below pipe 0.5+ ft, Total depth 2.0 ft. Eff. absorption area 200 ft2 Monitoring tube YES Depression over field NO Date of adequacy test NEW SYSTEM Results (Pass/Fail) For—bgdroGm Fluid depth in absorption field before test _ in. Water ad New depth _in. Elapsed Time: —min. epth _ in. Absorption rate >= g.p.d. enation treatment (past 12 mo.) (Y/N & type) If yes, give date **WILL BE INSTALLED WHEN PANEL IS MOUNTED ® THE HOUSE. ***WILL BE DONE WHEN THE HOUSE IS CONSTRUCTED D. LIFT STATION Date installed 3/7/2003 Size in gallons 1500 Manhole/Access (Y/N) YES "Pump on" level at TIMER in. "Pump off' level at- IMERin. High water alarm level at 46" in. Datum BOTTOM OF TANK Cycles tested NEW Meets alarm & circuit requirements? YES E. SEPARATION DISTANCES SEPARATION DISTANCES FROM WELL ON LOT TO: Septic tank/lift station on lot 100'+ Absorption field on lot 100'+ Public sewer main N/A Sewer /septic service line 25'+ On adjacent lots 100'+ On adjacent lots 100'+ Public sewer manhole/cleanout N/A Holding SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK ON LOT TO: Building foundation 5'+ Property line 5'+ Absorption Feld 5'+ Water main N/A Water service line 10'+ Surface water 100'+ Wells on adjacent lots 100'+ SEPARATION DISTANCE FROM ABSORPTION FIELD ON LOT TO: Property line 10'+ Building foundation 10'+ Water main N/A Water service line 10'+ Surface water 100'+ Driveway, parking/vehicle storage 10'+ Curtain drain NONE KNOWN Wells on adjacent lots 100'+ F. COMMENTS tr�a:ar_elc�_� G. ENGINEER'S CERTIFICATION I certify that I have determined through field inspections and review of Municipal records that the above systems are in conformance with MOA HAA guidelines in effect on this date. Engineer's Printed Name JEFFREY A. GARNESS Date 57/1 -7/04 - HAA /1'1/04 - HAA Fee $ 011 Date of Payment Receipt Number (Rev. 12!01) Waiver Fee $ Date of Payment Receipt Number ................... P A. essr 4s —7953 t1.er_ � cPAo Oct 18 05 04:56p P. Scott Peppers 907-694-9680 4 C*] ASBUILT HEREBY CERTIFY THAT I HAVE SURVEYED THE -OLLOWING DESCRIBED PROPERTY: '/E/t/o �Y/GG%tGO�dO.• �/O,/ GoT/ 6'.f%S NO THAT NO FNCROACHMEN�i EXIST EXCEPT AS NDICATED. IT IS THE RESPONSIBILITY OF THE IWNER TO DETERMINE THE EXISTENCE OF ANY 'ASEMENTS, COVENANTS, OR RESTRICTIONS !HIGH DO NOT APPEAR ON THE RECORDED SUBDI- 'ISION PLAT. UNDER NO CIRCUMSTANCES SHOULD NY DATA HEREON BE USED FOR CONSTRUCTION IF FENCE LINES, OR FOR ESTABLISHING BDUND- RY LINES. i 6bWJUW & ASSOCIATES LAND SURVEYING 694 -0:16 �? R t �� ... q e 4B: �.... .7` Dune Merk Sew d LS -5919 44:x�'�Ilk 1- cv l X'al m 121 P SO0'06'O0"E 270.06 (1~) L.SOO'13'OO"E 269.51 (M) 10' UTIUTY' ~AS'EME~N~ ' I I ~ d