HomeMy WebLinkAboutPROSPECT HEIGHTS #1 BLK 2 LT 22pfosQs�� I�u6hds�l. kA as Oct Municipality of Anchorage Page of? DEPARTMENT OF HEALTH AND HUMAN SERVICES ENVIRONMENTAL SERVICES DIVISION P.O. Box 196650 • Anchorage, Alaska 99519-6650 • Telephone: 343-4744 On -Site Wastewater Disposal System and/or Well Inspection Report Permit Number. 50C1i?01ekL' PID Number: 015-491 —Z3 NameEO At.1D DeetwA SaNE.L.(r.l Wastewater System: ❑ New XUpgrade Address Aga Ar- 9 vc ABSORPTION FIELD 9401. SLALorh I)IzlqE Phone:3L+ _91 o 9 Z No. of B7�edrooms: 0 Deep Trench XShallow Trench O Bed ❑ Mound ❑ Other LEGAL DESCRIPTION Soil Rating: n ' Total Depth from original Qrade: S.Sa — 8 • GPD/Sq Ft Lot: Block: Subdane Z P2o5.PBtf• C1 Depth to pipe bottom from original grade: 1, 4+G— Gravel depth beneath pipe 'q. yOa{ Z2. f1E1(-FfTG 3.9a Ft 07- — Ft Township: Range: Section: Fill added above original grade: 0. Gravel length: ��ttCC 77 —2-8s'— Ft Ft WELL: E3 Upgrade travel width: 5► Num er 1f hoes: Doyne xnveen Imes: E )STRNew Ft ClassitlWion (Private. ".C): Total Depth' sed To: Total absorption area Pipe material: P TIF Ft. Ft SO 5A SO Ft AST - O aI F-810 Dnber. Date Drilled: Static water Levet Installer.Date GhR.L.. Inst led: to jib — to/ 48 Ft. LAGJ1�(ATIn1G Y,eld: Pump Set at: Casing Height ADova Ground: * * TANK GPM Ft. R. SEPARATION DISTANCES gSeptic EXjSTU&ing ❑S.T.E.P. To Septic Ahsontion Lift Holding blUFri"le Manufacturer. Capac' ns: From Tank Field Station Tank Sewer Linn WelhMaterial: 11 Number of Compartments: Surface Water loo k+ — — _- LIFT STATION loo+ Lot1 I't i>S fi Size in gallons: Manufacturer. Line 1$ Foundation 51 1001•} �. 'Pump on' level at: 'Pump o at High water alarm at: curtainNOar: ti rte^ Pump Make Electrical Inspections performed by: Drain Remarks:* IDANFIR 6,zAono BENCH MARK CWS a3oo3) E SeRTIc. Location and Description: rA To of Gr.1:aGe FDdNO ?o BE of 60oo0 6o Aswmed Elevation: III G3 NitP, Tv 1& 4e . . EE�•�g EN+I-E`Ft�`EAL OFA��� r Aw e.Y-A/ LJ k" $ �A$fft4K 2 4*1& lL.TMrrS 10 It: 9 g Inspections performed by: Dates:ls - 1c, 2n 9g :, . ... ..... .•. 3ra to t� L�•� =tire A. Gamins �W Department of Health and Human Services approva •; r44' ,r.., E•795D by Qi�,—=,..✓ ld Date: oo/ .27-98 4PROFESS�� "RO, ES�i�, Reviewed and approved 72-013 Ili 9/91) MOA 25 PENUMBER: AS -BUILT DRAWING PARCEL. ID 1-23NUMBER: SWSW9803w9- `4 015-091-23 FINAL GRADE 96.38+ ( (�� ORIGINAL GRADE Mn COI ORIGINAL GRADE 98.00 J O�� (NORTH ENO) Mfg Cpl (NORTH END) rf+� �O•°`ri APPROXIMATE LOCATION /ORIENTATION RO, f OF SEWER SERVICE LINE —NOT I� INSPECTED BY A.W.W.C., INC. Jiiiii Y I NEW TH# INSULATED f�� \\\ C EXISTING TRENCH PRS \INSTALLED BULL RUN (BR) l \ BLZ CBLI WELL 1 ALASKA WATER AND WASTEWATER CONSULTAN'T'S, INC. 7320 E CHESTER HEIGHTS CIRCLE. ANCHORAGE. AK 99504 PHONE. (907) 337-6179/FAX: (907) 138-3246 1 _LCAL UIL9(;HIPIIUN: 0 PROSPECT HEIGHTS SUBDIVISION ADON. gt, LOT 22, BLK 2, IYPE 01 WORK: A AS—BUILT OF SEPTIC SYSTEM UPGRADE ✓�•• Q f ey Gorness; 'RLYAHL_pD hON: PHONE NUMBER: O E-7 ED AND DONNA SCHELIN 346-9092 d0�; C 9534 AIL: )HA*N BY: bl/•LL: YAUU••r dpr to 10/25/98 J.L.M. 1 = 40 2 OF 2 DOpp/e�feto' A 1 B C 6.0 9.4 40.8 17.5 37.7 22.6 36.8 23.0 N 35.8 24.3 45.9 — .0 104.5 .5 104.0.0 123.0.5 122.5 _LCAL UIL9(;HIPIIUN: 0 PROSPECT HEIGHTS SUBDIVISION ADON. gt, LOT 22, BLK 2, IYPE 01 WORK: A AS—BUILT OF SEPTIC SYSTEM UPGRADE ✓�•• Q f ey Gorness; 'RLYAHL_pD hON: PHONE NUMBER: O E-7 ED AND DONNA SCHELIN 346-9092 d0�; C 9534 AIL: )HA*N BY: bl/•LL: YAUU••r dpr to 10/25/98 J.L.M. 1 = 40 2 OF 2 DOpp/e�feto' MUNICIPALITY OF ANCHORAGE Department of HeaRh and Human Services i On -Site Services Program 825 L Street, Room 502 P.O. Box 196650, Anchorage, AK 99519-6650 (907) 343-4744 ONSITE WASTEWATER DISPOSAL SYSTEM PERMIT Upgrade AoM to- uo-" ik S'.SLUPm to - tot. `lk Date Issued: Oct 05, 1998 Expiration Date: Oct 05, 1999 Permit Number: SW980394 Parcel ID: 015-091-23 Legal Description: PROSPECT HEIGHTS #1 BLK 2 LT 22 Design Engineer. 0041 AK Water & Wastewater Consulta Site Address: 009401 SLALOM DR Owner Name: Ed & Donna Schelin Lot Size: 114563 SQ. FT. Owner Address: 9401 SLALOM DR Total Bedrooms: 3 Permit Bedrooms: 3 ANCHORAGE. AK 99516-1054 This permit Is for the construction of: ❑7 Disposal Field ❑✓ Septic Tank ❑ Holding Tank ❑ Privy ❑ Private Well ❑ Water Storage All construction must be In accordance with: 1. The attached approved design. 2. All requirements specified In Anchorage Municipal Code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80 ). 3. The engineer must notify DHHS at least 2 hours prior to each inspection. Provide notification by calling (907)343-4744(24 hours). ( Not required for a Water Supply Permit only). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must be either. A. Open and closed on the same day. B. Covered, sealed, and heated to prevent freezing. Received By: Issued By: a, 4 � 5, `"%'V j51n Date: O Date: /0 -16�_ R 8 Alaska Water & Wastewater Consultants, Inc. 7320 East Chester Heights Circle — Anchorage — Alaska 99504 (907) 337-6179 — Fax (907) 338-3246 Consulting Engineers October 1, 1998 Municipality of Anchorage Department of Health & Human Services Division of Environmental Services On -Site Services Section P.O. Box 196650 Anchorage, Alaska 99519-6650 Ref: Septic Upgrade Design for Lot 22, Block 2, Prospect Heights Subdivision Addn. #1 To whom it may concern: The existing 3 bedroom house is served by a private septic system and a private well. The existing seepage trench failed an adequacy test and must be upgraded prior to the sale of the house. A test hole was excavated to the northwest of the existing septic system. Comments regarding the proposed upgrade design are summarized as follows: 1. SOILS: Attached is the log which shows the soil profile, and the percolation test result. The soils below th organics is a ML material to a depth of 3 feet and than transitions to a SW/GW material to a depth of 9 feet. At 9 feet, the soils transition to a SP/SW material to a depth of 14 feet (bottom of test hole). A percolation test was performed at 5.0 to 5.5 feet which perked out at a rate of <1 minute/inch. No groundwater was encountered during excavation of the test hole. The insuti soils at 9 feet will act as a sand filter. 2. TRENCH DESIGN: a. Percolation Rate: <1 minutes/mch b. Allowable Application Rate: 1.2 gallons/day/ft2 c. Number of Bedrooms: 3 d. Design Flow: 450 gallons per day e. Minimum Absorption Area: 375 ft2 f. Effective Depth: 4 feet g. Reduction Factor = 0.50 h. Width: 5 feet (minimum) i. Minimum Length: 40 feet j. Effective absorption area = 400 ft2 (375 ft2 OK) k. Maximum depth = 7 feet (on uphill side of trench) 3. SURFACE WATERS: There are no surface waters within 100 feet of the proposed upgrade. 4. TOPOGRAPHY: As can be seen on the attached topography site plan, the lot runs from approximately east/southeast to west/northwest at a grade of 5-10 percent. In short, there are no slope concerns. I am unaware of any adverse impacts this installation would have on adjacent wells or septic systems. If you have any questions, please contact me at 337-6179. Thank you for your assistance. Sincerely, VA;;� James P. Williams, P.E. Civil Engineer LOT 7 PROSPECT kJCMTSK S%D /I SERVED BY PRNATE WELL / AND SEPTIC SYSTEMS PER M.O.A. RECORDS. NO ,/�, 1 HMFNTS ON THE PROPOSED SEPTIC SYSTEM. WELL LOT 21, BLOCK 2 � \ PROSPECT HEIGHTS S/b S�`'v�+ TH/1 ' ) E APPROXIMATE LO ION PROPOSED SEPTIC SYSTEM c~6 Of (SEE DESIGN, PACE 2 OF 2) / 0� \ ' 1 ' 100WELL FMIUS / 1 wETt , i /1 SEPTIC SYSTEM LOT 16A, BLOCK 2. PROSPECT YPRIHEIGHTS 5/D W11 ELL ' ' \ SERVED BY SYSTEM WEIR ANO SEPTIC SYSTEMS PER ' LOT 23, BLOCK 2 i i M.O.A.RECORDS. NO PROSPECT HEIGHTS 5/b p SERVED BY PRNATE WELL AND SEPTIC SYSTEMS PER M.O.A. RECORDS. NO ENCROACHMENTS ON THE PROPOSED SEPTIC SYSTEM. ALASKA WATER AND WASTEWATER CONSULTANTS, INC. 7320 E. CHESTER HEIGHTS CIRCLE, ANCHORAGE, AK 09504 PHONE (907) 117-6179/FAK: (907) 338-3246 PROSPECT HEIGHTS SUBDIVISION ADDN. #1. LOT 22. BLOCK 2, Oh WORK: SITE PLAN RLPARLD fOR: PHONL NUMULR: ED AND DONNA SCHELIN 346-9092 JAIL' )NAMN CY: .al/LL: YA.G: 10/1/98 J.L.M. 1 = 100' 1 OF 2 ENCROACHMENTS ON THE PROPOSED SEPTIC SYSTEM. ............................ -.JAMES P. WLUAMF& NO. 9608 •••., C.E. :' �d �i�e '••........••'' foo �pi.P�olenslo�� APPROXIMATE APPROXIMATE LOCATION OF A CUTBANK. NOTES: 1. THE EXISTING SEPTIC TANK IS TO BE EXCAVATED TO VERIFY THE INTEGRITY. IF OF POOR INTEGRITY THE TANK IS TO BE PUMPED, CRUSHED, AND ABANDONED COMPLETELY; AND A NEW 1000 GALLON OR LARGER SEPTIC TANK IS TO BE INSTALLED OUTSIDE OF THE WELL RADIUS. THE EXISTING SEPTIC TANK HAS BEEN GRANTED A 93 FEET WAIVER ON JUNE 21, 1993. 2. THE CONTRACTOR IS RESPONSIBLE FOR HAVING THE NORTHEAST PROPERTY LINE AND THE 100' WELL RADIUS FLAGGED BY A REGISTERED LAND SURVEYOR PRIOR TO CONSTRUCTION. /L� V QA:) � WELL ALASKA WATER AND WASTEWATER CONSULTANTS, INC. 7320 E CHESTER HEIGHTS CIRCLE, ANCHORAGE, AK 99504 PHONE: (907) 337-6179/FAX: (907) 338-3246 ICAL OLSCRIPIION: PROSPECT HEIGHTS SUBDIVISION ADDN. #1, LOT 22, BLK 2, G I YPL OF WORK: DESIGN OF SEPTIC SYSTEM UPGRADE RLPARLD FOR: rnunc nu,nocn: ED AND DONNA SCHEUN 346-9092 )MWN UY: 10/1/98 J.L.M. 1 = 40' I 2 OF 2 BULL RUN DNERTER DBL CO \ INC GALLON \ TANKK(SEE NOTES) \ 1 1� , , 49:P .v ............. MES P. N1LLAIM$ NO. 9608 ;! C.E. ..... ec4v .01 lo „. INSULATE ALL PORTIONS OF PIPE THAT WILL BE UNDER AND ADJACENT TO THE DRIVEWAY. PROPOSED ORN MAXIM cXGVATE ID DENIMUM)I J fry 8Y 5' WIDE(MINIMUM) BY 40' FEET LONG. ADD 4' OF CLEAN, WASHED DRAINROCK. / O /Co DRAINFIELD TO BE INSTAILED A, / PARALLEL TO SLOPE CONTOURS. TH#17� / EXISTING TRENCH TO BE J MTA \ USED AS A RESREVE SITE” APPROXIMATE APPROXIMATE LOCATION OF A CUTBANK. NOTES: 1. THE EXISTING SEPTIC TANK IS TO BE EXCAVATED TO VERIFY THE INTEGRITY. IF OF POOR INTEGRITY THE TANK IS TO BE PUMPED, CRUSHED, AND ABANDONED COMPLETELY; AND A NEW 1000 GALLON OR LARGER SEPTIC TANK IS TO BE INSTALLED OUTSIDE OF THE WELL RADIUS. THE EXISTING SEPTIC TANK HAS BEEN GRANTED A 93 FEET WAIVER ON JUNE 21, 1993. 2. THE CONTRACTOR IS RESPONSIBLE FOR HAVING THE NORTHEAST PROPERTY LINE AND THE 100' WELL RADIUS FLAGGED BY A REGISTERED LAND SURVEYOR PRIOR TO CONSTRUCTION. /L� V QA:) � WELL ALASKA WATER AND WASTEWATER CONSULTANTS, INC. 7320 E CHESTER HEIGHTS CIRCLE, ANCHORAGE, AK 99504 PHONE: (907) 337-6179/FAX: (907) 338-3246 ICAL OLSCRIPIION: PROSPECT HEIGHTS SUBDIVISION ADDN. #1, LOT 22, BLK 2, G I YPL OF WORK: DESIGN OF SEPTIC SYSTEM UPGRADE RLPARLD FOR: rnunc nu,nocn: ED AND DONNA SCHEUN 346-9092 )MWN UY: 10/1/98 J.L.M. 1 = 40' I 2 OF 2 BULL RUN DNERTER DBL CO \ INC GALLON \ TANKK(SEE NOTES) \ 1 1� , , 49:P .v ............. MES P. N1LLAIM$ NO. 9608 ;! C.E. ..... ec4v i ROSPECT711EGHTSLOT BK S%D /1 S LL .0 SYSTEMS ^RDS. NO ,'CRO ^ PRO .m0 SEP11 WE LOT 1, RDSPECf HEI H 5 / 1 �\ ♦ 1/1 '.SIN °PD T n• S� PRO OSED SEPTIC SYSTEM 'P? (SEE OESICN, PACE 2 OF 2)�y�o4Y! " a ^ IM T ON 18A BOC 2, P PE EIGHT S/D ERVED A ELL AND SEPTIC S PER LOCK 2, L1.O.A RECO S. NO PR ECT HEIGHTS S/O 1 ENCROACHME S ON THE SF +ED 9Y PRIVATE PROPOSED _DTIC SYSTE A J SEPTIC SVSTE PER M.O.A. RECOROS NO ..NCROACH4 ENTS PROPOSED SEPTIC EM. SA ATER + 7320 H C CIRC , AN 9 PHONE: 07) 7— 179/F (9 B ..LCA. OLSCRIPI :N: PROSP T HEI HTS S BDIV 10 DN. 1 L CK 2, E OF WO K: SITE LAN •RLPAR ' IDH: AND NNA SCH 1 0 LV L:T .v r c: 1 F 2 ALASKA WATER & WASTEWATER I SOIL LOG — PERCOLATION TEST I LEGAL DESCRIPTION: PROSPECT HEIGHTS S/D AODN. 11; LOT 22, BLOCK 2, PERFORMED FOR: ED AND DONNA SCHEUN DATE PERFORMED: 9/24/98 (feet ORGANICS TEST HOLE #1 7 � 2 6 9 10 11 12 16 TY/ f tl — TIGHT cf :d- SYV/GW C o:. a d SP/SW B.O.H. SOIL CLAS GIN CATION! ORG :' •' GP 1 11 111 1 ML r 116; I GM ME IN LESS CL i GC :I:I' OL SW MH '� =• SP CH SM OH �✓ard, Sc DATE DRY 1 10/1/8C I /I'll :` SITE PLAN 100' EXISTING TH/ SEPTIC SYSTEM APPROX. LOCATION PROPOSED SEPTIC SYSTEM (SEE OESICN, PACE 2 OF 2) i 5 1i1�F,y1M' WEL) i, WELL 1 DATE READING CLOCK TIME NET TIME (MINUTES) WATER LEVEL READING NET DROP (INCHES) 9/25/98 – FILLEE PERC CA 3 TIMES, DPJ INED OUT EACH ME IN LESS THAN 1 IINUTE. H LE ABSORBI D WATER AS. Fj Sr AS IT WAS Al DED. 19PERCOLATION RATE <1 (MINJINCH) PERC. HOLE DIA. 6' (INCHES) 20�I —JI TEST RLN BETWEEN 5.0 FT. AND 5.5 FT. COMMENTS: INSUTI SAND AT 9 FEET WILL ACT AS A D FlLTER. PERFOMED BY ALASKA WATER & WASTEWATER I, 1 iv– CERTIFY THAT THIS WAS PERFORMEDN ACCORDANCE WITH ALLTE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE. DATE d I `l `\ MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH & ENVIRONMENTAL PROTECTION I ENVIRONMENTAL ENGINEERING DIVISION j 825 L Street • Anchorage, Alaska 99501 Telephone 264.4720 ON-SITE SEWAGE DISPOSAL SYSTEM AND/OR WELL INSPECTION REPORT NAME PHONE /NE .(� 2Y' ._ /f4 ONEW O UPGRADE MAILING ADDRESS s ►e C; r►►t ,e 2 LEGAL DESCRIPTION Lot 22 G e 2 Pivs4led Ileigillf LOCATIONNO.OF {U erONso/V UffSr11u off /a/Ons PfCr u�%/ {6'frer BEDROOMS ' 3 O DISTANCE TO: Well10/ Absorption area ,� Dwelling 7.1 PERMIT NO. _Y HZ Wf- Manufacturer G/rrr Material Nr No. of compartments to Liq. capacilyin allons Inside length Width Liquid depth ti Y DISTANCE TO: Well Dwelling PERMIT NO. S?OzF Manufacturer Material Liquid capacity in gallons DISTANCE TO: Well //� Foundation 22 Nearest lot line ♦ PERMIT NW= O. n D/ZO ZW No. of lines f Lenflth of each line / Total length of lines o Trench width 24einches Distance between lines s.. Top of tile to finish grade Material beneath tile inches Total effective abs or tion area W V Length Width Depth PERMIT NO. i a W Type of Crib Crib diameter Crib depth Total effective absorption area DISTANCE TO: Well Building foundation Nearest lot line Class Depth Driller Distance to lot line PERMIT NO. W � DISTANCE TO: Building foundation Sewer line Septic tank Absorption area(s) OTHER L i PIPE MATERIALS C 1 /P SOIL TEST RATING _ fl '� r r INSTALLER t tr 4 f P Or ACAe;rc/t .f 6• 3G' 0 /9 REMARKS APPHOVED DATE LEGAL 11-12-62- U 72-0 13 1rtev. W78) ff1 0'A ''1' DR,1L L11N V OO l Dox 13GOp STr1R ROUTE A ANciaoxtAGE,, Ax.AsuA 99502 34n-7714 _ SIX INCH WATER WELL DRILLED AND CASED OUT TO THE DEPTH OF Z?S DRILLED AT THE RATE OF 122.00 PER FOOT. PROPERTY OWNER nt. Ed Scheun 276-2363 LOCATION OF WELL SITE Lt. B.tk.. sub. DRILLER Bein c Clain a.A Paapa,tt Dn LLUzu. !Jo&k4. WELL LOG: 0-----23' S.t,Ltty ;,tavaL. A dry. mate4 i.a,L wd th 30;'5 c, cj .L.indet. 23---325' Bedrock.. R 4edircmta uj..tack-. Ro water p&oducti.on 4how.ing unt.i,l. 260 •sect. 7 -ton 260 to 276 ..eet a wet gAar LUat t 1pe tock t�,Letd q ¢Gout 1/2 C,71,7. To•taL urate t p toduati.oa 4howbu7 50 gat4 pet haws. 1200 qzt 4 pet 24 Nowt .t iae J iwm. To•taL water .tecovevj. or_ --uLL draw down eveW 12 houA4. Sone adtcZUonat ltndLLCtion ./tom 300 .to 325 feet. At4a .tht4 1JeU. 4hou.Ld. iacAea e- .tn pto&c, ,loa wZM. u4c .to a aC44,l ie 75 to 85 gala pet howl. R One llorae Subne,%4Z&tc Tuan 4houW be .in�•ta tcd 20 4et ag Lo•tton. Co-dt o;L D.t.LIl irrt: 522.00 pet Pot X 300 deet artb ;;6600.00 COST INCLUDES ALL LABOR AND MATERIAL FOR COMPLETION OF SAID DRILLING. WRITE CHECK PAYABLE TO RAMPART DRILLING WORKS FOR THE SUM OF '$6600.00 THANK YOU VERY MUCH. BERNIE CLAUS OF RAMPART DRILLING WORKS DATE lane 27th, 1982 Q r. � RL I T'r• QF FirJr F 7F?n DEPARTMENT - HEALTH AND ENVIRONMENTAL PROTECTIO,' i 8.-25 'L' STREET, ANCHORAGE, AK. 95501 � 254-4720 i -.IEEE F-IrAE> CDr4-_.ITE SE14EF= PEFRt•1 I T PERMIT NO. ( 820170 ) APPLICANT ED SCHELIN 6910 CRANBERRY 2434554 ) LOCATION LEGAL L22 E2 PROSPECT HTS ADD 1 LOT SIZE 98000 SQUARE FEET TYPE OF SOIL ABSORPTION SYSTEM IS: TRENCH MAXIMUM NUMBER OF BEDROOMS = 3 SOIL RATING CSG FT/SP)= 95` THE REQUIRED SIZE OF THE SOIL ABSORPTION SYSTEM IS: G4EPTH= E+ LEr-IGTH= 25 rF F=ikrEL C•EPTH= THE LENGTH DIMENSION IS THE LENGTH CIN FEET) OF THE TRENCH OR DRAINFIELD. THE DEPTH OF A TRENCH OR PIT IS THE DISTANCE BETWEEN THE SURFACE OF THE GROUND AND THE BOTTOM OF THE EXCAVATION CIN FEET). THERE IS NO SET WIDTH FOR TRENCHES. THE GRAVEL DEPTH IS THE MINIMUM DEPTH OF GRAVEL BETWEEN THE OUTFALL PIPE AND THE BOTTOM OF THE EXCAVATION CIF! FEET). . F= EY,:U I F:EC• SEPTIC _rn"K 1LIDCFO 0nL_L_or4EE; PERMIT APPLICANT HAS THE RESPONSIBILITY TO INFORM THIS DEPARTMENT DURING THE INSTALLATION INSPECTIONS OF ANY WELLS ADJACENT TO THIS PROPERTY AND THE NUMBER, OF RESIDENCES THAT THE WELL WILL SERVE. Tt40 ti_ ? ? AF�E F?C- QU I FR.EC• --- BACKFILLING OF ANY SYSTEM WITHOUT FINAL INSPECTION AND APPROVAL BY THIS DEPARTMENT WILL BE SUBJECT TO PROSECUTION. MINIMUM DISTANCE BETWEEN A WELL AND ANY ON-SITE SEWAGE DISPOSAL SYSTEM IS 100 FEET FOR A PRIVATE WELL OR 150 TO 200 FEET FROM A PUBLIC WELL DEPENDING UPON THE TYPE OF PUBLIC WELL. MINIMUM DISTANCE FROM A PRIVATE WELL TO A PRIVATE SEWER LINE IS 25 FEET AND TO A COMMUNITY SEWER.. LINE IS 75 FEET. WELL LOGS ARE REQUIRED AND MUST BE RETURNED TO THE DEPARTMENT WITHIN 30 DAYS OF THE WELL COMPLETION. OTHER REQUIREMENTS MAY APPLY. SPECIFICATIONS AND CONSTRUCTION DIAGRAMS APE AVAILABLE TO INSURE PROPER INSTALLATION. PEF;:'M I T EXP I F?ES C•ECEME:EFs M:1, 1 E+52 I CERTIFY THAT 1: I AM FAMILIAR. WITH THE REQUIREMENTS FOR ON-SITE SEWERS AND WELLS AS SET FORTH BY THE MUNICIPALITY OF ANCHORAGE. 2: I WILL INSTALL THE SYSTEM IN ACCORDANCE WITH THE CODES. 3: I UNDERSTAND THAT THE ON-SITE SEWER. SYSTEM MAY REQUIRE ENLARGEMENT IF THE RESIDENCE IS REMODELED TO INCLUDE MORE THAN 3 BEDROOMS. SIGNED:--? --------------- APPLICANT EDcCHELIN ISSUED BY -- -- ---DATE------�-�-- o -Z cV4. 0 SOILS LOG MUNICIPALITY OF ANCHORAGE •� DEPARTMENT OF HEALTH AND ENVIRONMENTAL PROTECTION ❑ PERCOLATION 825 L. Street, Anchorage, Alaska 99501 2644720 TEST SOILS LOG - PERCOLATION TEST PERFORMED FOR: C [✓ _ / DATE PERFORMED: LEGAL DESCRIPTION:_ L Z Z rD Q �5 yled r /]'Q /G 4 DEPTH SLOPE / SITE PLAN (FEET) 1 2S 5 6 7 a 10 11 12 13 14 15 16 17 18 19 20 COMMENTS l d9,zJ J )2er p 9 -O%W. L I WASGROUND WATER /�S L ENCOUNTERED) P IF YES, AT WHAT /�� .i E DEPTH? Reading Date Gross Time Net Time Depth to Water Net Drop PERCOLATION RATE (minutes/inch) TEST RUN BETWEEN FT AND FT F . r PERFORMED BY: Jd' /"%. %'4• CERTIFIED BY: 72.008 (6/79) DATE:��1 Municipality of Anchorage Development Services Department 49 Building Safety Division — Onsite Water & Wastewater Program 4700 South Bragaw St. P.O. Box 196650 Anchorage, AK 99519-6650 www.ci.anchorage.ak.us (907)343-7904 CERTIFICATE OF HEALTH AUTHORITY APPROVAL FOR A.SINGLE FAMILY DWELLING (/ (/ Parcel I.D. 015-091-23 HAA# h �) �h' RO 3 1. GENERAL INFORMATION Expiration Date: ! .— — 19 — 03 Complete legal description _PROSPECT HEIGHTS 111 SUBDMSION- LOT 22 BLOCK 2 Location (site address or directions) 9401 SLALOM DRIVE • ANCHORAGE AK * 99507 Current Property owner(s) Mailing address Lending agency Mailing address Real Estate Agent Mailing address DANIEL HOLDER k NINA ANDERSON Day phone 349-6749 9401 SLALOM DRIVE ANCHORAGE AK. 99516 Unless otherwise requested, HAA will be held by DSD for pickup. 2. NUMBER OF BEDROOMS: 3 Day phone Day phone 3.- .TYPE OF WATER SUPPLY: TYPE OF WASTEWATER DISPOSAL: Individual Well 0 Individual On-sfte -Individual Water Storage ❑ Individual Holding tank ❑ Communfty Class Well ❑ Community On-site ❑ Public Water System ❑ Public Sewer ❑ The Municipality of Anchorage Development Services Department (DSD) Issues Certificates of Health Authority Approval (HAA) based only upon the representations given in paragraph 4 by an independent professional civil engineer registered in the State of Alaska. Certificates of Health Authority Approval are required for the transfer of title (except between spouses) for properties served by a single-family on-site wastewater disposal and/or water supply system. DSD also Issues HAAs upon request to homeowners. Certificates of Health Authority Approval are valid for 90 days from the date of Issue for properties served by a private or Class C well and may be reissued with new water samples. (Certificates may be reissued for a period of up to one year with valid water samples.) Certificates are valid for one year for properties served by Class A or B wells or a public water system. The Municipality of Anchorage is not responsible for errors or omissions In the professional engineer's work. 4. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, 1 verify that my investigation, based on procedures outlined In the Health Authority Approval Guidelines for this application, shows that the onsite water supply and/or wastewater disposal system is(are) safe, functional and adequate for the number of bedrooms and type of structure indicated herein. 1 further verify that based on the Information obtained from the Municipality of Anchorage riles and from my investigation and Inspection, the on-site water supply and/or wastewater disposal system is(aro) In compliance with all applicable Municipal and State codes, ordinances, and regulations in effect at the time of Installation. Name of Firm ALASKA WATER k WASTEWATER CONSULTANTS, INC. Address 3701 E. TUDOR ROAD, SUITE 101 • ANCHORAGE, AK 99507 Engineer's Printed Name JEFFREY A. GARNESS, P.E. Engineers Comments: In conducting this evaluation, AKW WC, Inc. attempted to provide a thorough, conscientious engineering analysis of the system In accordance with ADEC and MOA DSD Guidelines 6 Regulations. The reported results described the performance of the system under the conditions encountered at the time of the test, and separation distances measured to readily identifiable features. The operational life of all wells and septic systems depend on the local soils condition, groundwater levels that may fluctuate during the year, and the water usage of the fam#y being served by the system. These conditions are outside the control of the evaluator of the system. Satisfactory test results do not guarantee future performance of the system, nor do they guarantee that there are no hidden defects or encroachments. AKWWC, Inc. can therefore not provide any warranty or future estimate of how long the system will continue to meet the operational requirements of the ADEC or MOA DSD. The content of this report is for the sole benefit of the owner listed above. Any reliance upon or use of this report by any other person or party Is not authorized, nor will H confer any legal right whatsoever. 5. DSD SIGNATURE ✓ Approved for bedrooms. Disapproved. Phone 337-6179 Date 8 Z6 0 Conditional approval for bedrooms, With the Illowing stipulations: `�11tt1YlOFrrq��4 M'i �r VIIF i WATER AND PROGRAM Attachments: ,` HAA Checklist Manitenance Agreements /��� Septic System Advisory Supplemental Engineers Reort Well Flow Advisory Other By:— L /��, / &I Original Certificate Date: (Rw. 1201) Municipality of Anchorage ' Development Services Department Building Safety Division OnStte Water & Wastewater Program •'' " - 47W South Bragaw St. P:O. Bou 196650 Anchorage. AK 995196650 www.d.ardxnge.ek.us (907)943-7904 HEALTH AUTHORITY APPROVAL CHECKLIST Legal Description: PROSPECT HEIGHTS S/D #1: LOT 22, BLOCK 2. Parcel ID: 015-091-23 A. WELL DATA *CASED TO BEDROCK Web type PRIVATE if A, B, or C provide PWSID/f N/A Date completed 6/27/1982 SaNtary seal (YM) YES Total depth –.L25-11. Cased to 023 ft. FROM WELL LOG Data of test 6/27/1982 Static water level U.K. ft. Well production 0.8 g,p,m, WATER SAMPLE RESULTS: dD Coliform �k _ colonies/100 ml. Nitrate 0- 14 *1 mg./L. Well Log (YM) YES Wires property protected (YM) YES Casing height (above ground) 18+ in. AT INSPECTION 8/20/2003 34 lt. 0.42 g.p.m. Other bacteria '1%, colonies/100 ml. Arsenic: N/A mgA. Date of sample: 8/20/2003 Collected by: AKWWC, INC. 8. SEPTICIHOLDING TANK DATA Tank Type/Materhd STEEL Date installed 11/19/1982 Tank size 1250 gal. Number of Compartments 2 Cleanouts (YM) YES Foundation cleanout (Y/N) YES Depression over tank (YM) NO High water alarm (YM) N/A Date of pumping 8/22/2003 Pumper A+ HOME SURVICES C. ABSORPTION FIELD DATA Date installed 10/23/20039 8 Soll rating .p.d r fbd 1§ System type TRENCH Length 45/36 ft. Width 5.0/2.0 fL Gravel below pipe 4.0/4.0 ft. Total depth 8.00-8 0.5 fL Ef, absorption area 285450/7 ft' Monitoring tube YES Depression over field NO Date of adequacy test 8/20/2003 Results (Pass/FalgOtPASS For 3 bedrooms Fluid depth in absorption field before test 0 in. Water added 908 gal, New depth 15.5 in. Elapsed Time: 183 min. Final fluid depth DRY in. Absorption rate >" 450+ g,p,d, Any rejuvenation treatment (past 12 mo.) (Y/N 8 type) NONE KNOWN If yes, give date – **TESTED 1972 DRAINFIELD. NEW DRAINFIELD DRY ON 8/20/2003 D. LIFT STATION Date installed Size in gallons "Pump ore level at _in. E. SEPARATION DISTANCES High water alarm level at -in. Cycles tested Meets alar & circuit requirements? SEPARATION DISTANCES FROM WELL ON LOT TO: Septic tanknift station on lot 093' Absorption field on krt 100'+ Public sewer main N/A Sewer /septic service line 25'+ +WAVER GRANTED ON 6/21/1993 (WR930031) On adjacent Iota 100'+ On adjacent lots 100'+ Public sewer manhole/cleanout N/A Holding tank N/A SEPARATION DISTANCES FROM SEPTICiHOLDING TANK ON LOT TO: Building foundation 5'+ Property line 5'+ Absorption field 5'+ Water main N/A Water service line 10'+ Surface water 100'+ 100'+ Wells on adjacent kyts 100'+ SEPARATION DISTANCE FROM ABSORPTION FIELD ON LOT TO: Property Una 003'+ Building foundation 10'+ Water main N/A Water service line 10'+ Surface water 100'+ Driveway, parking/vehicle storage 1'+ Curtain drain NONE KNOWN Wells on adjacent kits 100'+ F. COMMENTS G. ENGINEER'S CERTIFICATION �4.%'�,r11- 11-: I certify that I have determined through field inspections and 4 ... • • •... review of Municipal records that the above systems ere in conformance with MOA HAA guidelines in effect on this date. • • •. • . • „ .,, ... • • ..,.. , Engineer's Printed Name JEFFREY A. GARNESS 4• -7953 Date Foro59 HAA Fee $ ?) 1 Date of Payment I - 1 03 r Receipt Number (Rev. luoi) Waiver Fee $ I s Q Date of Payment II f9 -6 -os Receipt Number " I k fiz Municipality of Anchorage ' Development Services Department Building Safety Division .... On -Site Water and Wastewater Program 4700 Bragaw Street P.O. Box 196650 Anchorage, AK 99519-6650 www.ci.anchorage.ak.us (907) 343-7904 Water Well Advisory Health Authority Approval # 030468 During a recent Health Authority Approval on-site inspection and test of the potable water supply well on Block 2, Lot 22 of Prospect Heights #1 subdivision, the well's productivity was determined to be 0.42 gallons per minute. The minimum well productivity required by this Department (AMC 15.55) for a 3 -bedroom residence is 0.31 gallons per minute. Although the subject well currently exceeds this minimum requirement, all parties concerned are advised that the production capacity of the well may fluctuate. Restriction of non-critical water uses such as washing cars and watering lawns and gardens may be required. This advisory must be attached to all copies of the subject Health Authority Approval. e— 2-03;11:40AM; SGS Ref # 1035362001 Client Name AK Water& Wastewater Consultants Inc. Project Name/# Prospect Hts N1.1.22. B2 Qient Sample ID Prospect Hts 9l, L22, B2 Matrix Drinking Water Sample Remarks: ;007 5815301 • 2/ 3 All Dates/times are Alaska Standard Time plated Date/time 09/0212003 1126 CollectedDateftime OWI/2003 5:00 Received DoteMme 08212003 1320 Technical Director eStephe .Ede Relaxed Parameter Qualifiers Results PQL Units Metal Comairermk LIMits Prep Mulnts Init to tc Water& Department Nitnte•N 0.147 0.100 mg/L IPA300.0 B (<'10) 0821/03 JJB 6 ALASKA WATER � WASTEWATER CONSULTANTS, INC. July 8, 2003 Municipality of Anchorage Development Service Department Building Safety Division On -Site Water & Wastewater Program P.O. Box 196650 Anchorage, Alaska 99519-6650 Ref: Lot Line Waiver for Lot 22, Block 2; Prospect heights Subdivision. To whom it may concern: We request that your department issue a 3 foot lot line waiver from the northwest property line to the existing drainfield. I am unaware of any adverse impacts this waiver would have on adjacent wells or septic sy ems. If you have any questions, please contact us at 337-6179. Thank you for your assistance 3701 E. Tudor Road, Suite 101 • Anchorage, AK 99507 Ph: (907) 337-6179' Fax: (907) 338-3246 • Website: akwwc.com 9/15/2003 Municipality of Anchorage :tfiirk IIct/ich, Mayor Btlilding Sttfcty Division P.O. Ikrc 196650 • 4700 13ragaw Strect Anchorage, Alaska 1X)511)-((')50 • (907) 343.8:301 • ram ((X)7) 343-82(X) h Iti):H%ti iv.numi.org Jeffrey A. Gamess Alaska Water & Wastewater 3701 E. Tudor Suite 101 Anchorage, AK 99507 Subject: Waiver Request for Prospect Heights #1 Block 2 Lot 22 Waiver Request #WR030081 Parcel ED #015-091-23 IIA030468 Dear Jeffrey Gamess: Your request for a waiver of the required 10 feet horizontal separation from the absorption field to property line has been approved. The approved separation distance is 3 feet. This waiver approval applies to the existing absorption field to property line separation only. Any future upgrade to the on-site wastewater disposal system will require all separation distances be met or another approval from this department. If there are any further concerns or questions regarding this waiver, please call our office at 343-7904. Sincerely, Jeffrey W. Poet Engineering Technician On -Site Water & Wastewater Program s�rrrr Municipality of Anchorage Development Services Department Building Safety Division On -Site Water and Wastewater Program 4700 Bragaw Street P.O. Box 196650 Anchorage, AK 99519-6650 www.ci.anchorage.ak.us (907)343-7904 Waiver Review Worksheet WR#: 30081 PID#:015-091.23 HAM 030468 Permit#: Date Received: 9/15/03 Legal Description: Prospect Hefahts #1 Block 2 Lot 22 Engineer. Alaska Water 8 Wastewater 3701 E. Tudor Road suite 101 Applicant: Daniel Holder & Nina Anderson Waiver Requested:_3 foot Lot Line waiver from the Northwest Prooertv Line to existing Drainneid Criteria: Geology Points: A. Water Table B. Soil Sorption C. Per ieabiiity D. Water Table Gradient E. Horizontal Separation Total: ......... ..................................................... .......... ......r Waiver Is Granted: Waiver is not Granted: List Conditions or Reasons for above: Date: By: Name of Reviewer ............................... was ... ago ... ...... ....... a.... a..... a ... .a.... ar Rec#: 41668 Amount $150.00 Date Paid: 9/15/2003 p LY 42°l 026. (J 7 GRAVE. GRIVMAY � ° � Y } tl 00, d Y '• 4tY�. i 3 EATELLITe DIY. 295.29 PATIO OWELL O 81 AS BUILT SURVEY NO GARNERS SET iH15 DAZE SCALE: 1' Y SP I HEREBY CERTIFY THAT I HAVE PERFORMED A MORTGAGEES INSPECTION OF THE FOLLOWNO DESCRIBED PROPERTY LOT =. BLOCK 3. PROSPECT HEIGHTS NO.1 o.BA.t,y�s�a^ 49 TH THE INFORMATION HEREON IS FOR THE USE OF LENDING INSTITUTIONS SPECIFICALLY TO SHOWANY CONFLICTS BETWEENPROPERTYLINESMDMOVISIBLEENCROACIIMENT; o°Yy" EXISTING STRUCTURES AND RUTTED LOT UNES OR EASEMENTS AND IS NOT TO BE USED FOR POSITIONING ADDITIONAL ............................. STRUCTURES OR FENCELINES SHANE A. HOLT ,• �� LS -8914 v In 'a V`,`°A ....... °. o �OO000�� N HOLT LAND SURVEYING .BSL. F845415.1O T--67 e P N Z°25 N 59 295.29 PATIO OWELL O 81 AS BUILT SURVEY NO GARNERS SET iH15 DAZE SCALE: 1' Y SP I HEREBY CERTIFY THAT I HAVE PERFORMED A MORTGAGEES INSPECTION OF THE FOLLOWNO DESCRIBED PROPERTY LOT =. BLOCK 3. PROSPECT HEIGHTS NO.1 ANCHORAGE RECORDING DISTRICT. ALASKA AND TH THE IMPROVEMENTS SITUATED THEREON ARE WTHI THE INFORMATION HEREON IS FOR THE USE OF LENDING INSTITUTIONS SPECIFICALLY TO SHOWANY CONFLICTS BETWEENPROPERTYLINESMDMOVISIBLEENCROACIIMENT; EXISTING STRUCTURES AND RUTTED LOT UNES OR EASEMENTS AND IS NOT TO BE USED FOR POSITIONING ADDITIONAL OTHER THAN NOTED. STRUCTURES OR FENCELINES DATED ATANCHORAGE, ALASKA THIS EASEMENTS OF RECORD. OTHER THAN THOSE SHOWAR N ON THE RECORDED FLAT. E NOT SHONN HEREON. _-BTM _ DAY OF—AUGUST NOS HOLT LAND SURVEYING .BSL. F845415.1O T--67 NOTEMy FENCELINES SIgNNME LOCATED APPFtOAMATELY AND ME NOT TO BE USED TO DETERMINE PROFERTY UNEI TEL 745-S513 ALIG-20-2003 12:28P FROM:A+ HOME SERVICES, IN 907-868-6770 70:3383246 P:111 h •y1IV � IV« �y0 A+ HOME SERVICES, INC;._ 7501 E. 140th Avenue Anchorage, Alaska 99516 345-1890 �`� CUSTOMER ? �n • an Mee& & can Anderson _ 940�1a14Di Anchorage, AK 995 6 1 AI, A, Inv INVOICE# 22500 DATE DESCRIPTION AMOUNT rump Sew--- -- $95.00 Week of SepL 73rd /D � ie� J�. rz . faX�✓ 349-6749 TOTAL REMARKS �� %� Gallons Septic Leach Area _.Holding Tank r Standpipes o'D Time ❑ PROBLEM AREA —CALL FOR MORE INFORMATION ❑ NEEDS TO BE DONE AGAIN IN 6 MONTHS Good Shape ❑ sludge buildup on bottom Floater on top ❑ Jim cap missing or ❑ Cut standpipe to V above ground ❑ Needs Septictrine needs replacing '010010X7 I� 1, O V0* ••,TOA ►Olt OOJ A+ HOME SERVICES , INC. CUSTOMER 7501 E. 140th Avenue Anchorage, Alaska 99516 345-1890 Lot �.7111 w . - ---I 1 1 1•, 1 INVOICE # 25742 DATE DESCRIPTION AMOUNT Pump Septic for adequacy teat 595.00 45 ti 4 9/021200 pHom 2 Teak local«! 10' from NE comekokhku TOTAL !� RE KS U Gallons ✓Septic Leach Area Holding Tank ❑ PROBLEM AREA— CALL FOR MORE INFORMATION ❑ NEEDS TO BE DONE AGAIN IN 6 MONTHS Good Shape ❑ sludge buildup on bottom ❑ Jim cap missing or ❑ Cut standpipe to 1' above ground needs replacing StandpipeV/i� Qy Time ❑ Floater on top ❑ Needs Septictrine MUNICIPALITY OF ANCHORAGE • �' DEPARTMENT OF HEALTH & HUMAN SERVICES Division of Environmental Services On -Site Services Section P.O. Box 196650 Anchorage, Alaska 99519-6650 343-4744 CERTIFICATE OF HEALTH AUTHORITY APPROVAL FOR A SINGLE FAMILY DWELLING Parcel LD. # 015-091-23 \• GENERAL INFORMATION HAA# Complete legal description —Lot 22; Block 2 • Prospect Heights -TIL Location (site address or directions) 9401 Slalom Drive Anchors a AK Property owner —rA A nnnn- cznhpiin Day phone aaF-Qoa? Mailing address 9401 Slalom Drive Anchorage, AK 99516 Lending agency Mailing add Day phone Agent Careen Nnir a r- rayitn n r Day phone 440-2899 Address Unless otherwise requested, HAA will be held for pickup. 2. NUMBER OF BEDROOMS: 3 y 3. TYPE OF WATER SUPPLY: Individual well XX- Community well Public water NOTE:: If community well system, provide written confirmation from State ADEC attest - Ing to the legality and status of system. 4. TYPE OF WASTEWATER DISPOSAL: Individual on-site XX Holding tank Community on-site Public sewer NOTE: If community wastewater system, provide written confirmation from State ADEC attesting to the legality and status of system. pass (R... war) F, ww On 5. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation of this Health Authority Approval application shows that the on-site water supply and/or wastewater disposal system is safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is in compliance with all Municipal and State codes, ordinances, and regulations In effect on the date o his inspection. Alaska Water & Wr �3 %� 6/75 Name of Firm r 34 .."1 ar •�G•//f� Phone Address 7320 Rj1?2WMFjF ALASKA WATER & WASTEWATER CONSULTANTS INC �(� OF IS TO BE PAID $2450.00 AT CLOSING FOR Q ENGINEERING SERVICES PERFORMED. t1�7�'I7-0 70 J01 � JeH YA. Gammt � W `, t%uT .•• CE -7953 •vii 6. DHHS SIGNATURE Q89Fo••..,«•,..••P��� V Approved for THREE bedrooms. Disapproved. Conditional approval for Additional Comments a 4t1TIC bedrooms, with the following stipulations: Date /0 The Municipality of Anchorage Department of Health and Human Services (DHHS) issues Health Authority Approval Certificates based only upon the representations given in paragraph 5 above by an Independent professional engineer registered in the State of Alaska. The DHHS does this as a courtesyto purchasers of homes. and their lending Institutions in orderto satisfy certain federal and state requirements. Employees of DHHS do not conduct Inspections or analyze data before a certificate is issued. The Municipality of Anchorage Is not responsible for errors or omissions in the professional engineer's work. M= MW IM) e.a uw m FCFIVE Municipality of Anchorage DEPARTMENT OF HEALTH & HUMAN SERVICES OCT6 e Environmental Services Division 825 L Street, Room 502 • Anchorage, Alaska 99501 RACE orvlsra, Health Authority Approval Checklist Legal Description: 1-.1• ZZ &eck 2 Aal t3cr PEJ&Nr Parcel I.D.: 615 -(t91 -Z3 .Suaoinst•r► I A. WELL DATA Well type PiZ vifgf If A, B, or C, attach ADEC letter. ADEC water system number Log present ®N) `(o S Date completed `/27 /+m Total depth :325 Cased to Z 3 (&OKOc$L- Casing height (above ground) 2'f Sanitary seal (VN) %iES Wires properly protected o N) Vp 5 FROM WELL LOO Date of test 6 /27 /SZ Static water level U. K. Well production 0.8 WATER SAMPLE RESULTS: AT INSPECTION g /18 /ma l 1'f I g.p.m. 0-(.(. — g -p.m - Coliform �0 Nitrate 0.43(. M, jL- Other bacteria 0 Date of sample: to /1'1/qB Collected by: _ALAsrA WRrs- 11= Iaiwrewlrlm C.09•~rs I wlc. B. SEPTIC410LDING TANK DATA Date Installed I 1 I Tank size I ISO Number of Compartments Z Cleanouts &N) Y sg_ P. Foundation cleanout (IDN)YF4 Depression OYN) �y High water alarm (Y(fb N o Date of Pumping i8 °%g Pumper A-& l&+c&F C. ABSORPTION FIELD DATA Date installed ID /Z.3/9 E Soil rating jgp.d oMlr/bdrm) 1-7- System type 'faa W -A 1 I Length yS Width S Gravel thickness below pipe 1 Total depth S I -9.6, Effective absorption area 146010 Monitoring Tube present (9/N) YES Depression over field (Y4% IJo Date of adequacy test Results (Pass/Fall) For 3 bedrooms Fluid depth In absorption told before test (in.); -- Immediately after= gal. water added (in.): Fluid depth -- (Ins) Minutes later. Absorption rate = c.p.d. Perodde treatment (past 12 months) (YM) If yes, give date 72-028 (Rev. 3196)• D. LIFT STATION is )ot Date installed Manhole/Access High water alarm E. SEPARATION DISTANCES 'Datum SEPARATION DISTANCES FROM WELL ON LOT TO: Septic/holding tank on lot C 931 Size in gallons 'Pump off" level at' On adjacent lots 100 1t Absorption Held on lot 1001+ On adjacent lots Public sewer main PJ I4 Public sewer manhole/deanout N / A Sewer /septic service line Z!51 + Lift station tiAW&t- C.Axo r&p eel (o/LI /93 iwR R 3oc3I SEPARATION DISTANCES FROM SEPTIVHOLDING TANK N LOT TO: Foundation 5 Property line 1513 Absorption Held 10 �+ It Water maiNe line 10 + Surface water/drainage)Dolt Wells on adjacent lots I UO SEPARATION DISTANCE FROM ABSORPTION FIELD ON LOT TO: � Property line C51f Building foundation I 00,:L Water main/service line I o r Surface water 100 r+ Driveway, parldng/vehicie storage area ZS Curtain drain Nowt ko4or.34 Wells on adjacent lots JOD It F. ENGINEER'S CERTIFICATION 1 certify that I in conforrnan inspections and review of Municipal 1s in effect on this date. / Signature Engineer's Name A * �6SJ i Date /v v6 o� HAA Fee $_,3 D 0. c7 Waiver Fee $ _ Date of Payment /'0 '1 ! Date of Payment Receipt Number T7 b � Receipt Number 72-026 (Rev. 3196)• are %q1I h� .I MUNICIPALITY OF ANCHORAGE M E M O R A N D U M WATER WELL ADVISORY HEALTH AUTHORITY APPROVAL NO. 9 $ 0 3 10 During a recent Health Authority Approval on-site inspection and test of the potable water supply well on Lot Block _� of PI O!SPE'e�T &6JP ZWSubdivision, the well's productivity was determined to be 0,44 gallons per minute. The minimum well productivity required by this Department (AMC 15.55) for a 3 bedroom residence is0 .31 gallons per minute. Although the subject well currently exceeds this minimum requirement, all parties concerned are advised that the production capacity of the well may fluctuate. Restriction of non-critical water uses such as washing cars and watering lawns and gardens may be required. This advisory must be attached to all copies of the subject Health Authority Approval. ALASKA WATER & WASTEWATER CONSULTANTS, INC. 7320 EAST CHESTER HEIGHTS CIRCLE • ANCHORAGE. ALASKA 99504 • PHONE. 337-6179 FAX: 338-3246 LEGAL STREET WELL FLOW TEST DATA CLIENT- En Aao WMA •S OEWJ PHONE NUMBER- 34L-`io9Z NUMBER OF BEDROOMS F.H.A. - FOUR HOUR FLOW TEST: MEASUREMENTS IN ME) YES / gD TEST DATE START____'_1,/_Id1s TEST DATE END `1 lE q8 z4 WELL DEPTH (PER WELL LOG): $zg1 CASING DEPTH (PER WELL LOG): 23' (9EP0_-CK _ CASING HEIGHT (ABOVE GROUND): 2y"+ M DEPRESSION AROUND WELL:- YES SANITARY SEAL:- <0 / NO WIRES IN CONDUIT: (!V) / NO WATER SAMPLES TAKEN: Q/ NO IF YES, DATE: 1,0/1.11116 TIME METER READING FLOWRATE (G.P.M.) WATER LEVEL (BELOW TOP OF CASING) DRAWDOWN H:2N 280-16 STATIC = 114' • O �• SZ' �B ••{•oTh�- �1:53 2 6.S' 1964 71 = G.57 257' —loss - 143' To L 1z 9 3C.0 4.0-7 312 5:1$ 28361.9 0.15 31-4'TAI- 5:2� 1Z83Lc.2 6.61 &test OFF --• 19EZ14 ca4ajtY 5; 21 93 ---- Rcnkea OFF 311' 4- 1' TorhL- 5 1310 +0 /4-7' reT ,. 5.31 • s1S. 0.-7'1 3og 411 tqI 5'ss 0. •74 3o-7 41' •t s 15f so 0.19 799 + ' + 13 5':SB 0.7 -Z +f 4'.4.1.1-r1 6.04 Z$ 60 6:112 8719Ie 0.66 WELL PRODUCTION MEASURED O �• G(o'r' COMMENTS: . OCT -23-93 13:31 FRW{TE ENVIRONI/ENTAL CT&E EnvitOnntontal Services Inc. AL 6615301 T-160 P.02/03 F-261 CUE Re1.N 986099001 CtlenL Pt7r Cllent Name AK Water g Wattcwucr Conml=rs Inc. Printed Da[e/ ITme 10123/98 11.12 Clkmtprojecl Namur nh t3Ff B 007. Printed Date/rime 10,'19/96 18:00 Client Sample ID PROSPECT HTSX L22,R2 Received Date/rime 10,20198 09:38 Hatrix Drinking Weser Ordered By Te"cal DReaor.. Stephen C. Ede Urde PWSID 00000 Rclttased By �wsamNlex=uLiw ►a ranapr OaLAttowame Crop Anilrafs RotulLa IA1ITa vww Lioits Date 04TO Infi MiLnMM O.C36 0.100 ey/L EPA U0.0 10 ets• 10/27/90 10/20/90 ecP rt MUNICIPALITY ANCHORAGE • DEPARTMENT OF HEALTH &HUMAN SERVICES �t Division of Environmental Services On -Site Services Section P.O. Box 196650 Anchorage, Alaska 99519-6650 343-4744 CERTIFICATE OF HEALTH AUTHORITY APPROVAL FOR A SINGLE FAMILY DWELLING Parcel I.D. # D15 -CAI -P-5 1. GENERAL INFORMATION Complete legal description 4or 22, alk 2, P(ioSPECi IferGerS. .AooN.tai Location (site address or directions) 9'y 01 SlaloM prime Property owner 6d ScAe(on Dayphone 273-SZdr Mailing address 9-2`01 Slalac, Or1vc,, Arch005o.e f}cc 995le, Lending agency Norf-hrlm bank Dayphone- 562-0062 Mailing address —3fit 4C" St.; A� ncl�Qe, Ak 99503 Agent N. A. ( Re Fnanc-C) Day phone Address Unless otherwise requested, HAA will be held for pickup. 2. NUMBER OF BEDROOMS: 2 3. TYPE OF WATER SUPPLY: Individual well ✓ Community well Public water NOTE: If community well system, provide written confirmation from State ADEC attest- ing to the legality and status of system. 4. TYPE OF WASTEWATER DISPOSAL: Individual on-site ✓ Holding tank Community on-site Public sewer NOTE: If community wastewater system, provide written confirmation from State ADEC attesting to the legality and status of system. 72-025(Ati'.1r91) Front MOA#21 5. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation of this Health Authority Approval application shows that the on-site water supply and/or wastewater disposal system is safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I furtherverify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is in compliance with all Municipal and State codes, ordinances, and regulations in effect on the date of this inspection. W41( - SephC d- Pro/)erky 4111[ ccw07✓t1-t need,-&( Name of Firm FlafLp 7-[c/1n'tca/ _�'e/✓Ice/ Phone 799--i3Ss- Address /v S' 3 D Echo Siy Ani e, Ak 995-/6 Engineer's signature TA.o-et � Date tun e 7, 993 6. DHHS SIGNATURE M A, Y 49to T" .y c Lot ..................:... . THEODORE F. MOORE ; C �¢ CE - 3539 ihq 'd —,Y\_ Approved for 2 bedrooms. Disapproved. Conditional approval for bedrooms, with the following stipulations: Additional Comments %N/S /y, A . A. / T f/!R R f f /.vAN! t . Date /,- 21- !'-? The Municipality of Anchorage Department of Health and Human Services (DHHS) issues Health Authority Approval Certificates based only upon the representations given in paragraph 5 above by an independent professional engineer registered in the State of Alaska. The DHHS does this as a courtesy to purchasers of homes and their lending institutions in order to satisfy certain federal and state requirements. Employees of DHHS do not conduct inspections or analyze data before a certificate is issued. The Municipality of Anchorage Is not responsible for errors or omissions in the professional engineer's work. 72-025 (Rot. 1/911 Back MOA 121 Municipality of Anchorage Department of Health & Human Services HEALTH AUTHORITY APPROVAL CHECKLIST Legal Description: LoT 22 Bk 2 PRosrccr Nrs Parcel I.D. ADON, #1 A. WELL DATA Weli type PRIVATE If A, B, or C, attach ADEC letter. ADEC water system number Log present (Y/N) %1 Date completed /e12T/82 Driller RAMPART Total depth 325 Casedto 231 6810100:: Casingheight 284 Sanitary seal (Y/N) r Wires property protected (Y/N) Absorption field on lot to 5 ; On adjacent lots >/00, Public sewer main N.A Public sewer manhole/cleanout M•A • Sewer service line X 851 Petroleum tank MJNf otssER✓ED � SGnova%7tn du/c�nc� Gva1✓t�' rKQurlYd WATER SAMPLE RESULTS: Coliform O col`110OM4 Nitrate 0.71 V/ -Q Otherbacteria Am, ederk-C Date of sample: 5113 )93 Collected by: FLATIJP TECH SVC!; B. SEPTIC/HOLDING TANK DATA Dateinstalled ((119182 Tanksize 1250 GA4. Compartments Cteanouts (Y/N) Foundation cleanout (Y/N) N Depression (Y/N) N High water alarm (Y/N) ILA Alarm tested (Y/N) N. A Date of pumping 51f3193 Pumper f SAAB s SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK TO: Well(s)onlot 921* from C•0• Onadjacentlots %1001 Foundation 7 To property line > 101 Absorptionfield S' Water main/service line e=90 Surface water/drainage > /oo' 72-026 (Rev. 791) Front CONTINUED ON BACK PAGE 0 FROM WELL LOG AT INSPECTION K G/2-11gi /I SIISf93 0 �� Date of test C rn Static water level 40 0 °i. Z M Well flow 0.16 g.p.m. 0 8 xo g. rr� co Pump level 3 fS = `0 (n w IT (Do �.m SEPARATION DISTANCES FROM WELL TO: m m Septic/holding tank on lot* 4y • �• ; On adjacent lots > 100' N Absorption field on lot to 5 ; On adjacent lots >/00, Public sewer main N.A Public sewer manhole/cleanout M•A • Sewer service line X 851 Petroleum tank MJNf otssER✓ED � SGnova%7tn du/c�nc� Gva1✓t�' rKQurlYd WATER SAMPLE RESULTS: Coliform O col`110OM4 Nitrate 0.71 V/ -Q Otherbacteria Am, ederk-C Date of sample: 5113 )93 Collected by: FLATIJP TECH SVC!; B. SEPTIC/HOLDING TANK DATA Dateinstalled ((119182 Tanksize 1250 GA4. Compartments Cteanouts (Y/N) Foundation cleanout (Y/N) N Depression (Y/N) N High water alarm (Y/N) ILA Alarm tested (Y/N) N. A Date of pumping 51f3193 Pumper f SAAB s SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK TO: Well(s)onlot 921* from C•0• Onadjacentlots %1001 Foundation 7 To property line > 101 Absorptionfield S' Water main/service line e=90 Surface water/drainage > /oo' 72-026 (Rev. 791) Front CONTINUED ON BACK PAGE C. LIFT STATION Date installed Size in gallons Vent(Y/N) High water alarm level "Pump on" levet at Meets MOA electrical codes (Y/N) Manufacturer Manhole/Access (Y/N) SEPARATION DISTANCE FROM LIFT STATION TO: Well on lot On adjacent lots "Pump off" level at Cycles tested Surface water D. ABSORPTION FIELD DATA Date installed ' 11 /19182 Soil rating q5 D' 4BCRM System type TRENCH Length 361 Width. Gravel thickness 4 Total depth 9 Total absorption area 289 ar Cleanouts present (Y/N) Y Depression over field (Y/N) N Date of adequacy test 5 / 189 3 _ s'/ 21 /9 3 Results (pass/fail) for 2 bedrooms Peroxide treatment (oast 12 months) (Y/N) —NONE KNOWN If yes, give date N.A •• SEPARATION DISTANCE FROM ABSORPTION FIELD TO: Well on lot 105'Onadjacentlots >/O0� Propertyline_30 To building foundation l3� To existing or abandoned system on lot N. A• On adjacent lots > 5°� Cutbank N.A. Water main/service line q' 90' Surface water > too' Driveway, parking/vehicle storage area Sr Curtain drain 1409E o13&1R✓Eb Y, Lol- lint waiver ne"o( E. ENGINEER'S CERTIFICATION I certily that I have checked, verified, or conformed to all MOA and HAA guidelines in effect on QQ&t2 of this inspection. VnQ Signature �%^� J Engineer's Name Th eo w -o --e F. me, a %yLaw .... .............. Date MtnP 7. 1993 Oj � � HEOOORE r. MOORED- ' Yl.; CE -3589 .o Ittvk: ••0 ....... � n Ar HAA Fee$ 170. op Date of Payment Receipt Number `� Lt n Lps 72-026 (Aft. Y➢i) Back MOA 21 Waiver Fee: $ If f/) . o o cue Il — fan k Date of Payment Io" LS3 Receipt Number a�-t7US =r COMMERCIAL TESTING & ENGINEERING CO. ► ENVIRONMENTAL LABORATORY SERVICES $-. Cf 1. RE Chemlab Ref.# :93.2163-3 Client Sample ID :L22 B2 PROSPECT HTS C1 Matrix :WATER Client Name :FLATTOP TECHNICAL SRV Ordered By :T.F. MOORE Project Name Project# PWSID :UA ANALYSIS COURTYARD HOSE* Sample Remarks: ROUTINE SAMPLE COLLECTED BY: T.F. WORK Order Report Completed Collected Received Technical Director Released By 5633 B STREET ANCHORAGE. AK 99518 TEL: (907) 5622343 FAX: (907) 5615301 :66031 :05/17/93 :05/13/93 @ 15:35 hrs. :05/13/93 @ 16:00 hrs. S C. EDE C• G QC Allowable Ext. Anal Parameter Results Qual. Units Method Limits Date Date Init ------------------- ---------- ------------�----------- --------------------------------------- Nitrate -N 0.76 r mg/L EPA 353.2/300.0 10 05/19 LLH * See Special Instructions Above UA = Unavailable ** See Sample Remarks Above NA - Not Analyzed U m Undetected, Reported value is the practical quantification limit. LT = Less Than D = Secondary dilution. CT = Greater Than %hI SGS Member o: the SGS Group (SocidI6 (3dndrale de Surveillance) ENVIRONMENTAL SERVICES IN ALASKA, COLORADO, UTAH, ILLINOIS, OHIO, MARYLAND, WEST VIRGINIA, NEW JERSEY, SOUTH CAROLINA ti Municipality of Anchorage Department of Health and Human Services Tom Fink, 825 "L" Street Mayor P.O. Box 196650 Anchorage, Alaska 99519-6650 343-4744 June 21, 1993 Ted Moore, P.E. Flattop Technical Services 14530 Echo Street Anchorage, Alaska 99516 Subject: Waiver Request for Lot 22 Block 2 Prospect Heights -#-2 }1I Waiver Request #WR930031, PID #015-091-23, HA930285 Dear Mr. Moore: Your request for waiver(s) of the required 100 foot horizontal separation of a septic system to a private well has been approved. The approved separation distance(s) are the private well to the septic tank 93 feet and the property line 3 feet.' This waiver approval applies to the existing septic system to well separation only. Any future upgrade to either will require all separation distances be met or another approval from this department. Sincerely, Daniel J. Roth Civil Engineer On-site Services 13m: #6 Concur: J hn Sm tqP rogram Manager On-site Services MUNICIPALITY OF ANCHORAGE Department of Health and Human Services' On-site Services Section Waiver Review Worksheet WR# WR930031 PID# 015-091-23 HA# HA930285 Permit # Date Received: June 8, 1993 ��{{ Legal Description: Lot 22 Block 2 Prospect Heights #,•"l Engineer: Ted Moore, P.E., Flattop Technical Services 14530 Echo Street, Anchorage, Alaska 99516 Applicant: Ed/Donna Schelin Waiver Requested: Well to septic tank 93 feet; property line - 3 feet Criteria: 1. Geology: Points: A. Water Table B. Soil Sorption C. Permeability D. Water Table Gradient E. Horizontal Separation TOTAL: 2. Special Conditions: 3. Other: Waiver is Granted: x Waiver is NOT Granted: List Conditions or Reasons for above: SEE 19�1�9fflFY> Date: By: Rec #: 24765 Amount: $.410,00 Date Paid: 6-8-93 �"i' � ���fJ/ �/moi// •- - ��"�ti _i.0 �. . , FLAfiTOP T�EGHNICAL SERV CE& CIVI. & ENVIRONMENTAL EINGLNEERLVG • ENERGY CONS ERVAnON & ANALYSis THEODORE F. MOORE, P.E. lune 7, 1993 14530 ECHO ST. P11: (907) 345-1355 ANCHORAGE, ALASKA 99516 M.O. A. DHHS P.O. Box 196650 Anchorage, AK 99519 Dear Sirs: By means of this letter we are requesting issuance of a waiver allowing the septic tank on Lot 22, Block 2, Prospect Heights S/D, Addn. #1, located at 9401 Slalom Drive, to be 93 feet from the well on the same lot instead of the normally required 100 feet. We are also requesting a waiver allowing the soil absorption trench on the same lot to be 3 feet from the property line common with Lot 21. A site plan, HAA application, and other relevant backup documents are enclosed for your review. According to the driller's log the well was completed in June of 1982 and has a total depth of 325 feet and a yield of 50 gph. On May 18, 1993 the static water level stood at 40 feet below the top of the casing. Steady pumping of 374 gallons of water from the well at an average pump rate of 8.5 gpm caused the water level inside the casing to be drawn down to the pump intake at 315 feet. We then measured the actual well yield to be 0.8 gpm over two subsequent recovery and drawdown cycles. Water samples collected on May 13 were satisfactory, with no reported coliform or other bacteria per 100 ml., and 0.76 mg/1 of nitrate -N. The wastewater disposal system was installed in November of 1982 and consists of a 1250 gallon septic tank followed by 36 lineal feet of soil absorption trench with 4 feet of sewer gavel beneath the distribution pipe. According to the as -built inspection report the septic tank is 103 feet from the well and the trench is 11 feet from the property line. Our measurements indicate that the septic tank cleanout is actually 94.6 feet from the well; the waiver request of 93 feet is to allow for underground projection of the tank. When we plotted the location of the cleanouts on an as -built survey of the lot, it appears that the monitor tube at the end of the trench is only 3 or 4 feet from the lot line. Thus, we are requesting a lot line waiver down to 3 feet in addition to the well -septic tank waiver. On May 18 - 21, 1993 we conducted an adequacy test of the wastewater disposal system. The initial fluid depth in the septic tank was a normal 48 inches, and in the sump at the end of the trench was 55 inches. We were able to add 112 gallons of water directly into the sump, causing its fluid level to rise 4.75 inches, without any backup into the septic tank. This unit capacity of 23 gallons per inch indicates that the trench is not operating in a surcharged condition, and the fact that the measured fluid depth is slightly greater than the reported gravel depth probably reflects the fact that the monitor tube was installed in the bottom of a low spot of the trench bottom. When additional water was added to the system, the fluid level in the tank started to rise along with the trench when the fluid depth in the trench exceeded 61 inches. To assess the adequacy of the system we measured the absorption rate when the fluid depth in the trench was between 59 and 60 inches. When the trench is filled to this depth, which is approximately I to 2 inches below the septic tank outlet, we measured the absorption rate to be 326 gallons per day, which is slightly over the minimum acceptable rate for a two bedroom residence. The property owner, Ed Schelin, has informed me that the residence actually has only two bedrooms, and that he is refinancing it as a two bedroom residence. The house is not being sold and in our opinion the wastewater disposal system may continue to function satisfactorily for the Schelins for several more years before it will need to be upgraded. As can be seen from the site plan, the lot is a large one and the topography slopes generally down from the southeast towards the northwest at approximately 15%, with the house being constructed on a bench leveled out of the slope. The house is located between the well and the septic tank, and should the septic system fail in such a manner as to cause effluent to daylight, it would tend to flow away from the well towards the northwest. The soils log indicates that the native material beneath the soil absorption trench is a silty gravel. A water table was encountered during breakup at 14.5 feet below ground level in the soil test hole, but the driller's log reports dry silty gravel extending all the way down to bedrock at 23 feet, and no water production in the bedrock borehole until 260 feet. This low production aquifer is confined and artesian as evidenced by the 40 foot static water level measured this year. The following is a possible assignment of waiver analysis points in conformance with ADEC SCRO's 1985 "Separation Distance Waiver Guidelines". Distance to aquifer (260' - 10' depth of tank bottom= 250') 7.8 Soil Sorption ((13' x 2.5) + (237'x 6))250 = 5.8 Permeability (all material with pert rate > 50 minlnch) 3 Water table gradient (assume 0% parallel to ground elevation differential) 2.9 Total 22.2 By this waiver point assignment it appears that there is little potential for contamination of the drinking water aquifer should the septic tank start to leak. The absence of bacteria in the water sample and the low nitrate reading provides further reassurance that there will be no potential public health problem created as a result of granting this waiver. Because of the large lot size in this area, granting a lot line waiver allowing the existing soil absorption trench to remain within 3 feet of the the property line common with Lot 21 will have no impact on the ability of the owners of Lot 21 to upgrade their wastewater disposal system at such time as it is needed. Please give me a call if you have any questions on this waiver request. I know the property owner will appreciate anything you can do to expedite the granting of the requested waivers and issuance of the HAA certificate. Sincerely, Ted Moore, P.E. cc: Ed Schelin I 1-6, as - L 7, 6,C v C: e LOT 22, 13t.NC 2 PROSPECT HTS., AVON #1 �% L,oT 21 4. r. ?6'LOH4 Sou ACS TCEnCH jk\I-Z-VV FAI,' T,+NN rN 2 CC-RHj p ! HOUSE 07 \ / Ewirtw: weL4 s (NO SEPTIC ' W ITN I N L•oT .23 '�� � / 100,� / Flattop Technical Services 14530 Echo Street Anchorage, Alaska 99516 . 1. 2Z 62/ PROSPECT NTS., ADDN #1 �......................:::.� W E I.I. SE P TI C S YS TE M �. ...........ids....... •THEODORE F. MOORE=• L S I T•E PLA N CE - 3589 A► . •, : B2 +���h^.,�04 .a 4P SCALE: 1"= 6o' Nors: TO a nor A ,A DATE: 6"MT SuRVBYSD ALL LOCATIONS ARE OWN. 0t•: TFP1 APPRO%INATE WAIvE/Y l?EQacsr Fon Lor 22 RLk 2 P/{oSPECr NEI6f17-5' 47-2 WgIv6R /4ERuEST NItMOER wR93D03/ Avg1V6R /{EquEfr foR ON -Loi Iv ELL ro SEPr/c rnowe or 93fffr -SfPrlc Nlsro?Y- TkE SE Pr/c_ sYSTE� _w/9f (va.rrRkCTFD I,v ,vov. /9s2, ...THE Fol? 3 OEDRoo.,� ur/�IZI,vG �+ /2s'o G�ccoti 61?Eari weft TKE fEPr/c r141%Ik v -/4-s CoAvsT?cccrEp L --IT/-/ IN✓6reTs o. 'AIL /t -C c E.rS 6/p rO ME r�tNk r1 -f/9 r k r/L / z E T 16Hr '< 0'"OL /N 65. L 61'k -411F /`14 0.-1 TK/I T7}�✓k r �� sTi1.. �TEO Du P�. :j7N11 >=14R SHoaLO PI` K/u�ngL OR Noti-Ex/JTE.�T• :.t lF_ Ir ELL ►-1qf f atisrRucrfp lav Tuur /982, Tito= c-FLL I1 L v c 4 rro I� RFFrff&V« rO rliC SEPTIC 7*.19AI& Iv QUEST/c ON TMr f4A(E s4PPxvx,*,4rE <a.vrouR, or TKuEgjlOAN 1J 32S DEEP, I .i FP Ar 2 3 FEET T kE SrAT l c L-/9 TER L E vEL /4i r,,/E w r_Lc fEFF rKE SOIL F/?oo-f 7-/1E GRoKtiO SmeFyCE I '.Iry PEORoCK If it S/L rY 61f/70,61 L, lrN .9P?/rcx,,�r.�TELr 30% .5,a r (ov rE uT, V ECI}usE rl-CE f7iS ric I -A rEK L E vcL ; /s Ar .g0' 1~141cH /s /7 "BELL v� rl-ee r4x/a6 -DEDRou� :'/NtERfACL/ 1w0/CItT6s NG IrarER Gorr/N6 /w TC' PY46 U ELL !FlZvlq THE �/9s/a6 - DfD.Pdf/�' /.tiT61Qf/¢CE, THE on. fuour rKE BEOR,,Cl- /S TYPICAL OF A (/poo F/L74,0 � AiArEM1R4 !!Jrl-(gr WILL TAAk C-"jpf,&r <O,KPLE7EL)-; 93�' fEEr J- '--r- 7 - e x=.72 t 2 Ire.. S. C. R, O. Po /" rs G I?AN0 T-0 r-4 3.D 2. 0 2. 9 ,2. 7 /2, 2- ( ( O/UCLt43/ow ,6E(,u.fF cf.solzj- ? PRoxir/Tr AE SEf7ic rAA,,' ro c-ELL� THE fNAutF s of SEP71c 7A,4 -l! Effc kC• ,r RfAtHi.6 Th'E e fc c AR[ v1pe 6 RA -4-,T LAW /✓£R ./ _ . . '!INf}TER TI�BcF 2 3 • �p TA..k DE>rN i'soi� Son e ri ow CRA✓EL I IIPF_Rrr`yy��iry � � fY3 HQo�E it 1.� !'�liA7'EI? Tp OLE GlPno�ENr :.I W ELL StPTiC ;-AP/( tArE %;,�[UN rO µ,'P o 93�' fEEr J- '--r- 7 - e x=.72 t 2 Ire.. S. C. R, O. Po /" rs G I?AN0 T-0 r-4 3.D 2. 0 2. 9 ,2. 7 /2, 2- ( ( O/UCLt43/ow ,6E(,u.fF cf.solzj- ? PRoxir/Tr AE SEf7ic rAA,,' ro c-ELL� THE fNAutF s of SEP71c 7A,4 -l! Effc kC• ,r RfAtHi.6 Th'E e fc c AR[ v1pe 6 RA -4-,T LAW /✓£R ./ _ . . T�C7 LtR`.l(laJ� Time APPLIC "NT FILLS OUT UPPER HACK, ONLY f+opertY Owner Phone Mailing Address S2li i2o �3J Zip Code 5,5 Buyer i C Address 21P Code d'j v y Lending Institution/mss c`1 Jnr. ,� / w Phone Address / U 3 / + 21p Code Realty Co. & Agent Date Mone Address /(Jn `O /1 Zip Code Legal Description �� yC 22 ����G. 2 �OS�iri-JL .✓�p��/„ 7P ���� �` Street Location Inspector Type of Residence (1/Single Family Multiple Family ❑ Other No. of Bedroom Water Supply Individual Community _ ATTACH WELL LOG. A well log Is required for all wells drilled since June 1975. ❑ Public Utility For wells drilled prior to that elate. give well depth (attach log If available). Sewer Disposal t1 ,On e— P v Individual Year Individual Installed: Public Utility ❑ Holding Tank When Connected to Public Utility: NOTE: THE INSPECTION FEE MUST ACCOMPANY EACH RECUEST BEFORE PROCESSING CAN BE INITIATED. T�C7 LtR`.l(laJ� Time TimeTerre Time �11 N r, Date Date Date Date Inspector Inspector Inspector Inspector �z �s P" Field Notes: �l MUNICIPALITY OF ANCHORAGE t1 ,On e— P v DFeT C' !,-".T�! F. ENVIR JX S.'._I,. A_ ; ..U. CCTION Ll.) G O..Jv UEC 17 1582 RECEIVED ( APPROVED BEDROOMS *CONDITIONS OF APPROVAL ( ) DISAPPROVED ( ) CONDITIONAL 4?R AL' DATE 7_ BY: .,� Soils Ratlnp Date Sewer Installed Well To Absorption Area Well Log Received — S—L Well to Tank Q3 Septic Tank Size rxaxvvsa Decenber 27, 1982 11. Edward Schelin SPA Box 2132 L . Anchorage, AR 99507 Subject: Lot 22 Block. 2 Prospect Heights Add. 07 Approval for the individual sewer and water facilities. cannot ////be granted until the following items have been completed: /< A well log cuhnitted to this office for our files and review. The top of the well casing should be sealed so that it is water tight. G (�° The water analysis report needs to be submitted to this office fron the Chen Lab, 5633 B Street, for our review. bl \ A four (4) inch cleanout needs to be installed to the sep- tic tank. A four (4) inch cleanout needs to be installed to the leaching area. Please notify this Department for a reinspection when the noted discrepancies have been corrected. If there are any further.questions, please call this office at 264-4720. Sincerely, K,v Robert C. Pratt Associate Environmental Specinlist RP254/p/E11 A