Loading...
HomeMy WebLinkAboutTHE TABLELANDS BLK 4 LT 11AMunicipality of Anchorage !/ Development Services Department }ti Building Safety Division .., .. - On-Sfle Water and Wastewater Program, 4700 Bragaw St. P.O. Box 196650 Anchorage, AK 99519-6650 Page / of 3 www ci.anchorage.ak.us (907)3417904 i ON-SITE WASTEWATER DISPOSAL SYSTEM AND/OR WELL INSPECTION REPORT I Permit Number. S_ _ W U X33 PID Number: O_KI Naa. S7Piti1E1 L FiMtES .rA Q. Wastewater System: rR New ❑ Upgrade A6 os% do Vf f rQ N- Q'J LiGNrs -`Zdd ABSORPTION FIELD I ell' Number a aebaxns p,D„p Trento 0 shallow Tnnrll O Bea O Mouse I D Oe+ar slsal LEGAL DESCRIPTION Ral•p Total Depth Iran wipes araee I GPD/F? R F1. 91ockJ la aVeeiYnMll Depth b ppo bonom Iran or •taias W ee GravN Beaiapipen barh p L N� r 3, S FI. I q FI Tw .p Rarq• sov.w Fe aeose aDow arpnY gape i Z Gravel Lenpin / I z F1. b FI. WeII:gWLJt� ew ❑ grade C."e`,dlh S Nim ofIrs Ehlll ahe1~1IMa I FI. FI Ciasamp"I'm (Proal•. A S. C Total Depth caw to Taal Wsorgion W" / �O PpaM .0 i1 Ft. Ft b F12 C JQ DNix Date Daley $u wml at InalalM� P1114 o Dale inalDee d a FL I naePiro s« M Caarq Nepn Grouse TAN K GPM FI. Fl SEPARATION DISTANCES Wseptic ❑ Holding ❑ S.T.E.P. ❑ Other. To Septic Absorption Litt Holding lublictPrivate " esu« +pant From Tank Field Station Tank Sewer Line F f OR Afk- 2 SQ " wait _ — — — — Mai w STEEL Nu a Convart ns I Z. s,xfapa waler Q(jJ`1- 160 's- _ IFT STATION La Lela �I�'f ���~ .za WI •uu« l d �t Plan, o^ level« 'perp 0"' Wr Jit ,yl 1. ala. at in i A Calan Gran Pump Moxa 6 Elect," lnspxro lnsW .,y ReMxs BENCH MARK I LOCapM an0 Dow,plim l 6 a .J '+" a.t/ "W,wi ».a4IX1 I CoQ FL � Inspections performed by: �%O 10% 2fwbT rte Dates: 1" /U Q Engineer's Stamp QF I - 2ne a O� �^ a: .•.....,,,�;i� r49TH' '•••'••��2d Development Services Department Approval x Conditional Approval Date: 00 !aA�............ •. r^ : Steven W. En W A Imo. 4� �f J'J,'•, PE 6456 V Reviewed and approved by: k4Date: 3- O(v V I�dpROF ��$1QNr�rr ,\"`a0'r✓� IRw 01'961% o� W ;Nm r w22 V In OS GiO m N CD < CLCD °a N < v �02ll� �a r N 0 P) EJ p--- ---- r y R- 117 h� 3 f t7 to U h N 'O IO UI U1 + < -qzn -5 0 V) o .+.< 3 UI 3 :3 + InDN3 3 n ;FE C7 P ry 3 O Ln 3 QZ � C o n 5'd 3 O (p 3 30 nt70to-1 �o pi-»�h on o ro on fU � r -t� UI r r �, r+ r-. u F-. N Ln Ln Y O) pp CJI v W ai ty ch � x < :2. P p -n 0 0 3Q ' 3 L ? W N r --I In rt f(1)M N 7 S m N CD < CLCD N < v m r c c 3 m a- 3 0 0 0 l rt O C 3 3 0 rt N CD r- 3 3 5 v° o� A� O vCD m 2T N ° O , m m M b n �� va 4 Ib N N bd r- 0 m n 7K -4 D -C�- tz r m rr O D � z d � I d i 1 N N h 2 O N rq m p h O 3 u co °S Ln 41 W N f'1 m +* p -oh Z oN-5-1 h37 ��'D i �n0 0 3 X.M-40n�'b-4 3 —I -h S1 O 3 h0 N F .+ X,Z Ooh f")O -nQ°3 R'3 O � r -m t43 (4 3N° O 5 Cl) -n Q M n h m !n N p _D CU f1 0 !+ 3 3 3. 0 h 3 3 O h ET C O 3 1311 fl 3 N S D N N P V1 -u h to A `< o n -0 (D '0h N IZ 3 n W r') o O 1 O p < A r0 n � Z h n N D Q f1 n v N p h m 3 r m M n v h m h CO mO 3 O t 11 %D S e+ .s II O n ~C I� 0 i m_ o m h O < O e+ II O kO 3 J> II Ln CP �. O A D N i o n o m 3p h 3 0 P O 27 p ^ - C-) 0 m 3 < ON -40 i N3 p h 0 3 c h N rr N p C+ O 3 II oiO% o i+ 3 Q I 0 O 00 h 3 O h � O °n -0 ry S O v 'O O N 3 f0 0 p 3 O C h N w h f N 3 rn m A .i p 3 R° --I I N 3 A S MUNICIPALITY OF ANCHORAGE Development Services Department On -Site Water & Wastewater Program 4700 South Bragaw Street P.O. Box 196650, Anchorage, AK 99519-6650 (907) 343-7904 ON-SITE WASTEWATER DISPOSAL SYSTEM PERMIT Initial Date Issued: Nov 15, 2005 Expiration Date: Nov 15, 2006 Permit Number: SW050433 Parcel ID: 051-801-19 Legal Description: THE TABLELANDS BLOCK 4 LOT 11 Design Engineer: 0838 North Rim Engineering Site Address: NHN WHISPERING BIRCH DRIVE Owner Name: SPINELL HOMES, INC Lot Size: 40000 SO. FT. Owner Address: 1900 W. NORTHERN LIGHTS BLVD #2( Total Bedrooms: 4 Permit Bedrooms: 4 ANCHORAGE. AK 99517 - This permit is for the construction of: Q Disposal Field r;� Septic Tank ❑ Holding Tank ❑ Privy ❑ Private Well ❑ Water Storage All construction must be in accordance with: 1. The attached approved design. 2. All requirements specked in Anchorage Municipal Code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72 ) and Drinking Water Regulations (18AAC80 ). 3. The engineer must notify DSD at least 2 hours prior to each inspection. Provide notification by calling (907) 343-7904 ( 24 hours ). ( Not required for a Water Supply Permit only ). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must be either: A. Open and closed on the same day. B. Covered, sealed, and heated to prevent freezing. Received By: _ Date: (k� OS Municipality of Anchorage Development Services Department \ Building Safety Division On -Site Water and Wastewater Program 4700 Bragaw St. P.O. Box 196650 Anchorage, AK 99519-6650 www.ci.anchorage.ak. us (907) 343-7904 ON-SITE SEWER/WELL PERMIT APPLICATION FOR A SINGLE FAMILY DWELLING Parcell.D. Iq Permit Number SW Property rn s. D phone3tJ[/" s671"' Mailing address /loci IA) ,(/,,, fq eih (,P -j gl j Zoo _Zip Code 9 9-7'7 Site address Code !i.Sl 7 v � / Legal description (Lot, Block & Sub'd.) 6 Legal description (Section, Township & Range) Lot Size Not b60 Acr s/Sq.Ft. THIS APPLICATION IS FOR: Number of Bedrooms y Sewer Only Well Only ❑ Sewer and Well ❑ Water Storage ❑ Sewer Upgrade ❑ THIS PROPERTY CONTAINS: Hot Tub ❑ Jacuzzi ❑ Swimming Pool ❑ Water Softening Unit ❑ Therapy Pool ❑ I certify that the above information is correct. I further certify that this application is being made for a Single Family Dwelling and is in accordance with applicable Municipal Codes. E (Signature of property owner or Permit/Rush Fees: 11 L41 0(1 00 Waiver Fees: Date of Payment: IDate of Payment: Receipt Number: ��� �/�j Sfiq) Receipt Number. (Rev. 09/04) 1TF ENGINEERING Northitim Engineering 17237 Bear Paw Circle Eagle River, AK 99577 907.694.7028 November 10, 2005 MOA On -Site Water & Wastewater Program 4700 Bragaw St Anchorage, AK 99519 RE: Tablelands, Block 4, Lot 11 A lot is being developed. The soil test was good. Groundwater was monitored during the high water month of October and is not present. A conservative design has been completed, similar to Block 4, Lots 22 & 23. The neighboring lots are mostly developed. This site should not negatively impact any of the other area lots. The lot slope is relatively flat and drops off in the rear of the lot. Please review the wastewater system design for the single family home. I have included design plans & specs, design guidelines, & soil tests. If there is need for additional information or clarification please give me a call. Sincerely, leve Eng, PE, PH Design Enclosures �C2TI�r�IM ENGINEERING Tablelands S/D, Lot 11, Block 4 SPECIFICATIONS & DESIGN GUIDELINES Wastewater System Sizing: This is a new 4 -bedroom, single family home. Some of the neighboring lots are not yet developed. Groundwater was monitored during the high time of the year in existing subdivision test holes and was not present. A conventional septic system is designed similar to the designs on lots 22 & 23, Block 4. This lot is over 1 acre in size and no adverse impacts are expected from development. The neighboring lots are similar. The lots are served by a public water system. No conflicts to the other lots will take place by this septic system construction. The easements are located on the drawing and are not encroached upon. Soil tests revealed sandy soil with low silt. An application rate of l GPD/FT2 with 0.5 reduction factor for utilizing a 5' wide trench. Trench Length = 600 FP/5'x .5 reduction factor = 60'; 1 line @ 60'. No bedrock was encountered. Specification Requirements: All components and work must comply with the Municipality of Anchorage Specifications (AMC) & State of Alaska Drinking Water Regulations and Wastewater Regulations. • Two compartment, 1250 gallon septic tank. Watertight couplings on inlet & outlet. • 5' minimum between the tank and bed. 10' to property lines. • 3' of cover or insulation is required for trench; an equivalent of 1" insulation for each foot soil cover. • Tank & solid pipe must be set on well compacted, stable soil. • 4 inch diameter cleanouts with airtight caps are required 1' to 4' from foundation wall, prior to any 90 degree bend in 4 inch line, in each tank compartment, and two adjacent opposing cleanouts between the tank and the absorption field, not more than 10' from the tank positioned to provide cleanout access towards the tank and towards the absorption field. • All cicanouts must extend to at least ground level. • In solid pipe runs, ASTM D-3034 may be used in lieu of cast iron. • Trench to be placed level, minimum of 4' to groundwater, 6' to bedrock from drain -rock. • Drain rock to be %2 inch to 2'/2 inch screened. Drain rock to be distributed uniformly throughout the trench. • Perforated pipe to be installed level with perforations down. • Silt barrier (filter fabric) to be installed above the drain rock. • Smeared trench sides must be raked or scarified before drain rock placement. • Backfill over drain rock must not be less than 36". • The finish grade must be mounded to promote drainage over the trench. • Insulation must be placed over any pipe installed under driveways or parking areas. • Approved pipe materials include cast iron, PVC ASTM D3034, PVC ASTM F789, ABS ASTM D2661, • Sewer Service Line is minimum 2% slope. • Septic Tank to be pumped every two years or when required. • Insulation board to be extruded direct burial polystyrene (Dow Styrofoam FII or equal) O� C E O J w-. O �+ N J (n E E 0 00 7 O V) �C E O C E E T Q p �^ o > r_ •n J J W Vis o � > v a� J p°' ` cn N °' pq Q Z 0 c` u N Y F-u to o 3: c y W Q m (n F- (n F- J F PPI y^ W D CV M Z W A CD a CD ° W ~ W N V)/ :p S 3 u o� 3 W Q O Z IA V) Q •N 3 d. �✓ a�9npp/. v w u £ (U o N L (n N t: •• �pQ 4tn v W E O Oc T}.p� �= C) p uz(i jt !! Rd;' 3 Cl-N -P a, ^, u, o o a £ > .. L\ A a)o \yam PCI�ta °2K eq mISIZ Y 4 O N g V) A J 0 W J Y a t,) C3 = J F- PQ1 g J b N J VI E E t io E k } £ o u $Z N = G o ri u V1 A 121 N J 0 r l`) Ih 'f Y 4 O N g V) A J 0 W J Y a t,) C3 = J F- PQ1 S u C L L I -- C$ d H u 4' CL N c w o, 3 W 0.l tA 0 O C d a, U (3) C in O CL O. O i t 0 z �L w A �0 f s Q O H J J w CL J �^ PQd- a, A Q A F— Y N U L wo U u F— Pq d 4. N _ ¢ 4. U ~ p� W a CL 'O U N f v w d V N u L C U N O) d 0 d OO £ O U JZ - L) U U c o Q cx o o CJ f a L +fid N F- ALN O. d U N S2-0 �£p) £ 033 7C) U� O d -P O £ Q 3 os U . C'o_£� op4 0 °ow t� vric °oaoNC)s£a, tN L �O NQ .+ • N.a4 — d LON a Jo£L O oil UNL O CO A L+. aJ U d U N U {+ fn O --5 c.O 4,FN Oi�U £ FW- e O N CXL L 0— Z t US L LN z Lo N 3 N Q N Q N N (L M -t Ln ,.0 0 z N w A J s Q O H J J w W J �^ PQd- Q A F— Y U L wo C3 F— Pq z N _ z w 3 J H LL > A A C z w w z N _ ¢ >- U ~ N w F- CL w w V N c j \u \[ )'a £c cs �u i:p CL 75 tun \ E , b]m ODd w £L�-p /�\� Atm§ tj�\ §(§ § 9 rr=I »UT zQe EI e0% L 0eme� Ld Nw4CV) 'v ti 4t ,� J. / 0 E ILLJILN G Q �!� /Z §N/( w tI — ) �■w - 23)t �� _a \ \/ t a® �A E \ f \ • '0 ,� ®t } ,� ®t i; k �V. - �� � \ • L — § :;� # 0 •i i 3 • w @ / \ \ ti 4t ,� J. / . !,m ILLJILN G Q �!� /Z §N/( — .,� �■w - 23)t �� _a t a® ,� ®t ,� ®t i; �V. - �� :;i®� • — :;� # •i i 3 • ti / !,m ILLJILN G Q �!� /Z §N/( 23)t _a FRIM\ S❑ILS LOG - PERC❑LATI❑N TEST r' IIM Date Performed: 11/2/05 INEERING Performed For; Spinell Homes Legal Description, Lot 11, Block 4 1 - 2 - 3 - 4 - 5 - 6 - 7 - 8 - 9 - 10 - 11 - 12 - 13 - 14 - 15 - 16 - 17 - 18 - 19 - 20 - 21 - DEPTH (FEET) Slope < 5% Groundwater? Nb Depth Water Depth AC+o" Mnn1+nr1nn. Nnna Date, 11/8/05 & 10/25/05 #` Organic Gross Time Net Time Depth Net Drop 1 SP ' -- 7' Sand 2 11/2 ;;• •:? w/Gravel .:'. 0.5' 3 11/2 5 -- ;j. -- 4 11/2 7 2 min. 8' 0.5' 5 11/2 10 -- 7.5' -- 6 11/2 12 2 min. Slope < 5% Groundwater? Nb Depth Water Depth AC+o" Mnn1+nr1nn. Nnna Date, 11/8/05 & 10/25/05 #` Date Gross Time Net Time Depth Net Drop 1 11/2 0 -- 7' -- 2 11/2 2 2 min. 7.5' 0.5' 3 11/2 5 -- 7.5' -- 4 11/2 7 2 min. 8' 0.5' 5 11/2 10 -- 7.5' -- 6 11/2 12 2 min. 8' 0.5' Percolation Rate 4 min./inch Perc Hole Diameter 6' Test Run Between 3' and 4' Comments)Pre-SankPCI Performed By NorthRim Eng. I Performed in Accordance with All ON THIS DATE. DATE, 11/8/05 Z CERTIFY THAT THIS TEST WAS State/Municipal Guidelines in Effect THE TABLELANDS S/D GEOTECHNICAL T.H. 1 LOT 11 BLOCK 4 /8/05 11 of 2 NORTHRIM :~ism. y' ENGINEERING ... 17237 Bear Paw circle Alaska 99577 Eagle River, 907-694-7028 Z CERTIFY THAT THIS TEST WAS State/Municipal Guidelines in Effect THE TABLELANDS S/D GEOTECHNICAL T.H. 1 LOT 11 BLOCK 4 /8/05 11 of 2 S❑ILS LOG - PERC❑LATI❑N TEST TH, IM— Date Performed: 11/2/05 pt" GINEERING Performed For: Spinell Homes Legal Description: Lot 11, Block 4 1 - 2 - 3 - 4 - 5 - 6 - 7 - 8 - 9 - 10 - 11 12 - 13 - 14 - 15 - 16 - 17 - 18 - 19 - 20 - 21 - DEPTH (FEET) Slope < 5% r Groundwater? No Depth Water Depth n ACI-- u....^1+�r.i.•^J•a Alnno nn+OI tt/Ans #` Organic TIr1e Net TIme De th SP ' Sand 0 •. oc-�w �{' 8' w/Gravel 2 11/2 2 2 Min. 8.5' 0.5' 3 11/2 5 -- 8' -- 4 11/2 7 2 rain. 8.5' 0.5' w 11/2 �ttom^ -- 8' -- Slope < 5% r Groundwater? No Depth Water Depth n ACI-- u....^1+�r.i.•^J•a Alnno nn+OI tt/Ans #` Date IGross TIr1e Net TIme De th Net Drop 1 11/2 0 •. oc-�w �{' 8' 2 11/2 2 2 Min. 8.5' 0.5' 3 11/2 5 -- 8' -- 4 11/2 7 2 rain. 8.5' 0.5' 11/2 10 -- 8' -- 11/2 12 2 Min. 8.5' 0.5' P65 Percolation Rate 4 Min./inch Perc Hole Diameter 6' Test Run Between 3' and 4' Comments: - Performed By NorthRim Eng. I CERTIFY THAT THIS TEST WAS Performed In Accordance with All State/Municipal Guidelines in Effect ON THIS DATE. DATE: 11/8/05 THE TABLELANDS S/D GE❑TECHNICAL T.H. 2 LOT 11 BLOCK 4 2 of 2_' OF NORTHRIM ENGINEERING 17237 Boor Pow Clrclo Cagle Ri"r, Alosko 99577 •. oc-�w �{' ?07-694-7028 THE TABLELANDS S/D GE❑TECHNICAL T.H. 2 LOT 11 BLOCK 4 2 of 2_' 4 r..,, Municipality of p y Anchorage -ji A '-a - Development s� • Development Services Department Building Safety Division y. On -Site Water and Wastewater Program ' 4700 Bragaw Street " "' P.O. Box 196650 Anchorage, AK 99519-6650 www.muni.org/onsite (907)343-7904 CERTIFICATE OF ON-SITE SYSTEMS APPROVAL FOR A SINGLE FAMILY DWELLING Parcel I.D. �%Jr/- So/- �S COSA #_ Expiration Date: — �� — p -7 1. GENERAL INFORMATION Complete legal description 7-144-' 407-11 Location (site addressQ_ JDR (n/l-i t $PE/eIA16 B /RCI A /z&zz- Current Property owner(s) .SP/.t1A5ZL 90.o►F f 7 -AX Day phone _Wc j-54C7J' Mailing address r.✓ x oencv?rt/ G7 --r -0-oO Lending agency Day phone Mailing address Real Estate Agent Day phone Mailing Address Unless otherwise requested, COSA will be held by DSD for pickup. 2. NUMBER OF BEDROOMS: 3. TYPE OF WATER SUPPLY: TYPE OF WASTEWATER DISPOSAL: Individual Well ❑ Individual On-site Individual Water Storage ❑ Individual Holding tank ❑ Community Class Well ❑ Community On-site ❑ Public Water System Public Sewer ❑ The Municipality of Anchorage Development Services Department (DSD) Issues Certificates of On -Site Systems Approval (COSA) based only upon the representations given in paragraph 4 by an independent professional civil title (except between spouses) for properties served by a single-family on-site wastewater disposal and/or water supply system. DSD also Issues COSAs upon request to homeowners. Certificates of On -Site Systems Approval are valid for 90 days from the date of issue for properties served by a private or Class C well and may be reissued with new water sample results. (Certificates may be reissued for a period of up to one year with valid water samples.) Certificates are valid for one year for properties served by Class A or B wells or a public water system. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. 4. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below. I verify that my Investigation, based on procedures outlined in the Certificate of Onsite Systems Approval Guidelines for this application, shows that the on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from my Investigation and Inspection, the on-site water supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal and State codes, ordinances, and regulations In effect at the time of installation. Name of Firm A16 c f i letotl EAG Phone 49' 9 — %OLS Address �/ 7.2 3 7 13EA2 P,A7..-r r204 -E Engineer's Printed Name Date 'PZzlooe 01F AHL _ s. Cir_._ it F '. Stemo w. E C•, 5. DSD SIGNATURE `�t:�F� •,,. PE 6256 M _� Approved for bedrooms. Disapproved. Conditional approval for bedrooms, with the following stipulations: Attachments: COSA Checklist X Septic System Advisory Well Flow Advisory Arsenic Advisory Maintenance Agreements Supplemental Engineer's Report Nitrate -Advisory Other (Rw.11,05) Certificate Date: S —2,? -06 Municipality of Anchorage ,• Development Services Department Building Safety Division On -Site Water & Wastewater Program 4700 Bragaw Street P.O. Box 196650 Anchorage, AK 99519-6650 www.muni.org/onsite (907) 343-7904 CERTIFICATE OF ON-SITE SYSTEMS APPROVAL CHECKLIST Legal Description: 'FPO-' 77#444`1 n/41 &Qr. - fOrit Parcel ID: A. WELL DATA I) -W W U — PUB 4Cr Well type & If A, B, or C provide PW SID # _ B. Date completed Total depth ft. Date of test Static water level Well production WATER 77c,ColiformArsenic: FROM TS: Sanitary sea YIN) Caged t ft. iNEL OG ft. g.p.m. mL Nitrate mg/L Date of sample: TANK DATA Well Log (Y/N) Wires properly protected IN) Casing height (above nd) in. AT INSPECTION ft. g.p.m. i I Other bacteria colonies/100 mL Collected by Tank Type/Material < X 6fa9406-5- lC ^ .S!CEL Tank size [ZSO gal.- Number of Compartments 2 Foundation cleanout (Y/N) V Depression over tank (Y/N) --Ar Date of pumping NiffAn 1 Pumper C. ABSORPTION FIELD DATA Date installed a_/_E Q�_�'6 Soil rating (g.p.d./ft2 oof�lbdrm) 1. Length �2 ' ft. Width Date installed 1/dZ0 I Cieanouts (YM) High water alarm (Y/N) System type T�2�i�1cN Gravel below pipe ft. I Total depth jL4_ ft. *" Eff. absorption area L� ftz Monitoring tube 4— Depression over field Al— Dale of adequacy test Ah5A- ) Results (Pass/Fail) For I I bedrooms Fluid depth in absorption field before test _ in. Water added_ gal. New depth_ in. Elapsed Time: _ min. Final fluid depth _ in. Any rejuvenation treatment (past 12 mo.) (YIN & type) I Absorption rate >= I g.p.d. If yes, give date D. LIFT STATION Date installed Size in gallons Manhole/Access (YIN) 'Pump on' level at_i 'Pump off" level at_ in. High water alarm level at in. Datum Cycles tested Meets alarm & circuit requi ements? E. SEPARATION DISTANCES SEPARATION DISTANCES FROM WELL ON LOT TO: PUE I C tr,. ,47'£r2. Septic tanknift station on lot Absorption field on lot Public sewer main Sewer /septic servj6e line Animal containgfent areas On adjacent lots On adjacent lots Public sewer m Holding tank excrete storage areas SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK ON LOT TO: / / r Building foundation s -E Property line /Gf f Absorption field s 4 Water main a A0 /•f Water service line 16 r'r Surface water 0 /•i .200' -'e - SEPARATION Wells on adjacent lots �Q -t' SEPARATION DISTANCE FROM ABSORPTION FIELD ON LOT TO: Property line /O r{ Building foundation G rt Water main Water Service line / (S /� Surface water ��Q /� Driveway, parking/vehicle storage Z 0 t'r' Curtain drain I Wells on adjacent lots 2-00 rt' F. COMMENTS G. ENGINEER'S CERTIFICATION I certify that I have determined through field inspections and review of Municipal records that the above systems are in conformance with MOA COSA guidelines in effect on this date. Engineer's Printed Name .57-i5\6E Date P- 2,Q COSA Fee $ 7 r�us Z, Waiver Fee $ Date of Payment g - Z Z ' Date of Payment Receipt Number g S O G Receipt Number (Rev. 11/05) y Sieftn W. Eng PE 6256 Te,;! ........ **,-t