HomeMy WebLinkAboutSANDY ACRES LT 4Sandy Acres Lot 4 #015-501-43 Municipality of Anchorage Development Services Department Building Safety Division On -Site Water and Wastewater Program. 4700 Bragaw St. P.O. Box 196650 Anchorage. AK 99519-6650 Page of www ei.anchorage.akus (907) 343.7904 ON-SITE WASTEWATER DISPOSAL SYSTEM AND/OR WELL INSPECTION REPORT Permit Number. SWO5043251 PID Number. 015.50143 Marianne Braund Wastewater System: ❑0 New [3 Upgrade Am 6345 Fairweather Drive Anchorage, AK 99516 ABSORPTION FIELD Fear 317-5844 Fames a e.000ar Four P Dmo Tiod DSI Taw, DOW! D Mand 0011W Taro.rannanawaada LEGAL DESCRIPTION .45 GPlwr eFI. SMK 1a:4 NMWPVseammnanagiM Vp am eeara CTal dVP Sand Anes Y 2 Fl, 6 Fr Tawrqft sol Faaddadaddwagrrl Vsds Ca Vga, 1-3 Fl, 112 FI. Well: New Upgrade C" �'dtl'. anon aMw, Ddrinlerwa ; 3 A. CMaamraem (FMre, A Is. Q ued Tar 0"th Cb TaanFl r aand ana Pq Marin Private 117 p, 117 FT 1,344 FP ASTM D3034 PVC Dar Ona Dalad. SM WarU MrrYsr. orswraaad Alpine Drilling 3/10/2006 1 63 Fl Red Dog Excavating 228 to 322006 wand pu "vamCrapH.gnaod `7 TANK 20 GPM R 2 FL SEPARATION DISTANCES 0 Septic ❑ Holding ❑ S.T.E.P. ❑ Other. To Septic Absorption t.M Holding Mdk•JPrNaW 'a'"°r M Flom Tank Field Station Tank Sdo<r Lk,,, Anchorage Tank 1,250 Gr 101 r rano. aCanprwnsre W+ >100' >100' WA WA WA Steel Two (2) S.d Wr >107 >100• WA WA LIFT STATION 1.01uP• >s >17 WA WA Gr 'Pare an' MM r 'FnQ df YM al I.p� carr aYnn k Foneam' >6 >17 WA WA h k k PVnq Maks & Mar Elscn:r Inws Prbmod W Carr or— Nona Noted Rr . BENCH MARK lnrmd w D.aapiad. Garage Stab 100.00 FL 2128/06 UaaaAt ole Inspections performed by: A-Harala Dates: 11 .r.'� z 3106 NG;,: Development Services Department Approval s : 49-U .'* Conditional Approval Date: ....... ...........a T, •a . MICHAEL 9. ANURIZY� • It 17 6c► / Date: OC �:. all Rorts314^y4:1 Reviewed and approved by: — <<llits�ti Ina,. Indw.m Municipality of Anchorage DEVEOPMENTSERVICES DEPARTMENT 4700 Bragaw Street Anchorage. AK 99519-6655 - 343.7904 On -Site Wastewater Disposal System or Well Inspection Report Permit No. SW050451 MM S2 35.0' 49.8' C4 537 64.8' 1 C5 78.9' 72.5' I M7 79.0' 73.3' I I SV 54.2' 57.8' 1 C6 73.5' 83.8' 1 C7 93.0' 89.6 bg I M2 93.6' 90.5' 8 31 WI o �I 01 z I I I LOT 4 SANDY ACRES SUBDIVISION 44,229 S.F. 49th ' A eMICHAEL E. ANDERSON N 8T56'15'E 185.00' 10' T. & E. ESNT.-------L— I ®TH3 I � I I M2 1 C6 C7 TH3A M1 1 SV C5 i � � S2 , 0 j y ., LULIAD I i0 CIRCLE J 1 1 PLAN AS -BUILT SCALE 1' - 50' W* Page 2 of 3 PID No. 015-501-43 Municipality of Anchorage Page 3 of 3 DEVEOPMENTSERVICES DEPARTMENT 4700 South Bragaw Street Anchorage, AK 99519-6655 - 343.7904 On -Site Wastewater Disposal System or Well Inspection Report Permit Number. SWO50323 (u cum N N PID No. 015-50141 Ln U F= f U d U SOUTH TRENCH 4YVA Drainfield Rock SG (Trench Length) NORTH TRENCH PROFILE AS -BUILT No Scale MUNICIPALITY OF ANCHORAGE DEVELOPMENT SERVICES DEPARTMENT 4700 BRAGAW STREET ANCHORAGE, AK 99519-6650 SOILS LOG — PERCOLATION TEST LEGAL DESCRIPTION: LOT 4, SANDY ACRES SUBDIVISION PERFORMED FOR: MARIANNE BRAUND DATE: 2/28/06 PROJECT No.: PARCEL ID#: TECIINICIAN: A. HARALA DEPTI l TEST HOLE A (rap 1ZZ4 OB/OG 2 is 3 4 5 ... 6 •, SILTY SAND W/GRAVEL 7 r :. SM 8 9 SITE PLAN SEE SITE PLAN q BOH @ 10' WAS GROUND WATER ENCOUNTERLDt No 10 IF YES p WIIA DEI Ill' DEPIII OF WATER AFTER MON RORMG: 0-20X0 I I DATE OF MONITORING: 12 13 14 15 16 17 18 19 DATE READING GROSS TIME (MINUTES) NET TIME (MINUTES) DEPTH To WATER(INCHES) (INCHES) INET DROP TEST HOLE PRESOAKED PRIOR TO TESTING: 2/28 1 2:11 4.38" 2 2:41 30 5.75" 1.37" 3 2:43 3.75" 4 3:13 30 5.12" 1.37" 5 3:15 4.00" 6 3:45 30 5.37" 1.37' PERCOLATION RATE. 22 (MIN/INCIn PERC. HOLE DIA 8. �� IINCHES) TEST RUN BETWEEN---7—FT. and 5 FT. COMMENTS: TEST HOLE PRE SOAKED PRIOR TO TEST. TEST PERFORMED TO VERIFY UNIFORMITY OF SOILS. SOILS ENCOUNTERED ARE VERY SIMILAR TO THOSE ENCOUNTERED IN TEST HOLE 3. TEST PERFORMED BY ANDERSON ENGINEERING. 1, MICHAEL E. ANDERSON CERTIFY THAT THIS WAS PERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPLE GUIDELINES IN EFFECT ON THIS DATE' 12/7/2006 man 0j t Marianne Braund 907-248-5522 P.1 ALPINE DRILLING & ENTERPRISES Permit Number: #SW050451 Date of Issue: 12-9-05 Parcel Identification Number: 015-501-43 Date Started: 3-10-06 Date Completed: 3-10-06 Is well located at approved permit location? ® Yes ❑ No Legal Description: Sandy Acres Lot 4 Property Owner Name & Address: Marrianne Braund 6345 Fairweather Dr Anchoraae. Alaska 99518 Borehole Data: Depth (ft) Method of Drilling ® air rotary ❑ cable tool Soil Type, Thickness & Water Strata From To Casing type: steel gravelly silt silt gravelly silt silty gravel! 0 11 31 50 50 31 50 61 Wall Thickness: .250 inches Diameter: 6 inches Depth: 117 feet Liner Type: Diameter: inches Depth: feet Casing stickup above ground: 2 feet silty water sand &gravel 61 64 Static water level (from ground level): 63 feet gravelly silt 64 85 Pumping level: 115 feet after silt 85 101 2 hours pumping 20 gpm silty water sand & gravel 101 117 Recovery Rate: 20 gpm Method of Testing: airlift Well Intake Opening Type: ® Open End ❑ Open Hole ❑ Screened Startfeet Stopped feet ❑ Perforations Startfeet Stoppcd feet Grout Type: bentonite vranulest Volume: 1bg Depth: Start 0 feet Stopped 7 feet Pump: Intake Depth feet Pump size hp Brand Name Well Disinfected Upon Completion? ® Yes ❑ No Method of Disinfection: chlorine tablets Comments: Well Driller: Alpine Drilling & Enterprises PO Box 110496 Anchorage AK 99511 Attention: The well driller shall provide a well log to the property owner within 30 days of cpmplction and the property owner or the well driller shall provide a well log to the Development Services Department within 60 days of complr.1n. MUNICIPALITY OFANCHORAGE Development Services Department On -Site Water d Wastewater Program 4700 South Bragaw Street P.O. Box 196650, Anchorage, AK 99519-6650 (907) 343-7904 ON-SITE WASTEWATER DISPOSAL SYSTEM / WATER SUPPLY PERMIT Initial Permit Number: SWO50451 Legal Description: SANDY ACRES LOT 4 Date Issued: Dec 09, 2005 Expiration Date: Dec 09, 2006 Parcel ID: 015-501-43 Design Engineer: 0014 Anderson Engineering Site Address: 10674 LULIAD CIRCLE Owner Name: MARIANNE BRAUND Lot Size: 44229 SO. FT. Owner Address: 6345 FAIRWEATHER DRIVE Total Bedrooms: 4 Permit Bedrooms: 4 ANCHORAGE. AK 99518 - This permit is for the construction of: 0 Disposal Field E Septic Tank ❑ Holding Tank ❑ Privy ❑✓ Private Well ❑ Water Storage All construction must be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal Code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations ( 18AAC72 ) and Drinking Water Regulations ( 18AAC80 ). 3, The engineer must notify DSD at least 2 hours prior to each inspection. Provide notification by calling (907) 343-7904(24 hours). ( Not required for a Water Supply Permit only). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must be either: A. Open and closed on the same day. B. Covered, sealed, and heated to prevent freezing. 5. The following special provisions. a.) Additional test holes and percolation tests shall be conducted in the locations shown on the Site Plan prior to the construction of the on-site wastewater disposal system. Soil togs including percolation test results shall be submitted with the Installation Report. Received By. Issued By. Date: 12 -1 Z a S Municipality of Anchorage Development Services Department Building Safety Division `i Onsite Water and Wastewater Program 4700 South Bragaw St. P.O. Box 196650 Anchorage, AK 99519-6650 www.ci.anchorage.ak.us (907)343-7904 ON-SITE SEWER/WELL PERMIT APPLICATION FOR A SINGLE FAMILY DWELLING Parcel I.D. ny5 - 6t w 43 Permit Number SW Property owner(s) Marianne Braund Day phone 317.5844 Mailing address (1) 6354 Fairweather Drive Anchorage AK 99518 Mailing address (2) It &gq Luliad Circle Zip Code Legal description (Lot, Block & Sub'd.) Lot 4. Sandy Acres Subdivision Legal description (Section, Township & Range) Lot Size 44,229 SF Acre q.Ft:" THIS APPLICATION IS FOR: Number of Bedrooms Four (4) Sewer Only ❑ Well Only ❑ Sewer and Well ® Water Storage ❑ Sewer Upgrade ❑ THIS PROPERTY CONTAINS: Hot Tub ❑ Jacuzzi ❑ Swimming Pool ❑ Water Softening Unit ❑ Therapy Pool ❑ certify that the above information is correct. i further certify that this application is being made for a Single Family Dwelling and is in accordance with applicable Municipal Codes. (Signature of property owner or authorized agent) Permit Fees: a SfGD=Sr►nc. �l7f~�.+ Date of Payment: Receipt Number.3G3 d��r (Rev. 12100) Fees: Date of Payment Receipt Number. ANDERSON ENGINEERING P.O. BOX 240773 ANCHORAGE, AK 99524 522-7773 677-7766 FAX November 17, 2005 Municipality of Anchorage Development Services Department On -Site Water and Wastewater Program 4700 South Bragaw Street Anchorage, AK 99519-6650 Subject: Lot 4, Sandy Acres Subdivision Septic System Design and Permit Application Impacts to Adjacent Properties Dear Onsite Services Engineer: The owner of Lot 4, Sandy Acres Subdivision intends to construct a new four-bedroom home on the lot. We are therefore requesting a permit be issued for the construction of a new well and septic system to accommodate the home. The attached Site Plan and backup documentation identify the location and configuration of the proposed well and septic system along with the alternate site. Also identified on the plans are the locations of wells and septic systems on the surrounding lots. No conflicts exist between the proposed septic system and those on adjacent lots. Drainage arrows are shown indicating the surface slope of the property in the area of the new septic system. Test holes were placed on the lot in the area of the absorption trench and alternate site, which indicated a silty sand with some gravel (SM/SP) material.. The percolation rate of the materials was determined to be 17 to 60 minutes per inch. No groundwater was found during the placement of the test holes, but was noted at 13' and 14' during the monitoring period. An application rate of .45 gallons per day per square foot was used in the design of the absorption system. We are proposing to place a new 1,250 -gallon septic tank and 2-56' long by 3' wide by 6' effective depth absorption trenches to treat and dispose of the effluent generated in the house. The elevation of the distribution line in the absorption trench will be 2' below the surface and the total depth will be 8'. A minimum of 3' of fill will be placed over the absorption trenches and 4' over the septic tank. A flow splitter valve will be installed to insure even flow to each trench. The ground surface on the lot in the area of the septic system slopes gently to the northwest. The new trenches will be constructed parallel with the slope as much as possible in conformance with Municipal requirements. The new septic system will be constructed a minimum of 100' from all wells and any surface water and 10' the Lot 4, Sandy Acres November 17, 2005 Page Two proposed and existing water services in the area. If the system is constructed in accordance with our design the following statements apply: 1. The system, if constructed as designed, will have no adverse impact on the wells in the area or those to be constructed in the future. 2. The system, if constructed as designed, will have no adverse impact on existing septic systems in the area or those to be constructed in the future. 3. The system, if constructed as designed, will have no adverse impact on reserve space, either surface or subsurface, on any lots located in the area. 4. The system, if constructed as designed, will have no adverse impact on drainage patterns in the area. The current drainage pattern will be maintained. Sincerely, n� " OW'4 , 4f GCa•dc- Michael E. Anderson, P.E. Attachments lee, e 4i0 Ai.l C. AADER50'. IC NO. CE -4381 f �' Z IQ— � i 7 Y ••° iLWJ r DiOf � m s 4 .••;C't i Z 101 W78 •♦•� ����i..�.••'••••• .WWI xalr-m WWI a� to co ,jy,a, N 10I ct� a • •ye-• 4 • N WC. A = (— • O WV Q Z Q A�aaaa26 0b 021 .1311b'W, 0 SANDY ACRES SUBDIVISION LOT 4 44,229 S.F. 504' 510' N 89'56'15*E 165.00' i 10' T. & E. ESMT. L---- v - ---------------i I ws 4` 'rlIs2-56' Long x 3' Wld I o{e Oe x 6' Effective Dept • I P`{err Absorptlon Trenchei I 1 � *'ni3 I I 1! Flow Sputter I Valve 1 I Ic 5 n V) i I W t3 I I z O o I 1250 Gallon19 N ,Y I Septic Tank I o 4. 1 PJ�J Non.. 1 O d1 + bo �1 I I Z I f Hom v. ♦ + I Ole. I o I I +JiB, PrRd ®d d I I I I , 1 / I � LULIAD CIRCLE SITE PLAN SCALE V = 40' 1"I z 518' th�j �. �y �•��( a�lv.4r.`... it L L mDmsm,f i o. CE 4]el .% �i tom— �_. N 89'56'15'E 114. 522' 15' T. k E. do GAS ESM . 518, SITE PLAN SCALE V = 40' 1"I z 518' th�j �. �y �•��( a�lv.4r.`... it L L mDmsm,f i o. CE 4]el .% �i tom— �_. LOT 4, SANDY ACRES SUBDIVISION DESIGN FACTORS: SYSTEM REQUIREMENTS: Four Bedroom Home Deep Trench System Perc. Rate: 17.60 Min./Inch 1,250 Gallon Septic Tank Application Rate: .45 GPD/SF 6' Drainfield Rock 4 Bedrooms X 150 GPD/.45 GPD/SF (Application Rate) = 1,333.3 SF Absorption Area 1,333.3 SF/12 SF/LF =I 11.1 LF Trench Length THEREFORE: Construct 2-56' Long x 3' Wide x 6' Effective Depth Aborption Trenches at the Location Shown. Flow Line Elevation in Trenches to be 2' Below Original Ground Surface. Total Depth to be 8' Below Existing Ground. Provide T of Cover Over Trench and 4' Over Tank or Provide 2" of Insulation and 2' of Cover. Maintain 10' Separation From Water Services in the Area. Natural Backfill 1'6" Geotextiie Fabric 6" (sPVC HoleDown) 6'0" 3' Drainfield Rock TYPICAL DEEP TRENCH SECTION (NO SCALE) i NOTE: Grade Area Over Trench to Drain Away. a Minimum 6' Separation From Bedrock. •.....i Minimum 4' Separation From Groundwater. i Minimum 100' Separation From Private Wells in the Area. i �, Minimum 100' Separation From Surface Water or Streams. .1iO � Minimum 10' Separation From Water Service Line. ;16� 49th No. CE4381 ALASKA WATER & WASTEWATER *;' CONSULTANTS. INC. 7 5:10 — IIJI m.xu• .....� — nrrmwi•SOIL LOG — PERCOLATION TEST LEGAL DESCRIPTION: SANDY ACRES SUBDMSION• LOT 1-4 QQ4 PERFORMED FOR: - TOM' BLOMDELD DATE: s/23/2003 1 T/-4 EPRI�T. (feet - == ORGANICS TEST HOLE 1 .B.O.H. SILTY LOAM SOIL CLASSIFICATIONS 2 Y o; GW ORG TH13f 17- 718PERCOLATION GPML 3 18— GMCL a GCOL Iy" PERCOLATIONRATE -+ PERC. HOLE DIA. 6 (INCHES) 4 .• •o.: SWMH z TEST RUN BETWEEN 6.0 FT. AND 6.5 FT. •. ••. •. $PCH A FOUR HOUR PRESOAK WAS PERFORMED: m SOILS LOGGED BY: SUSAN 5 COMMENTS: SM OH' LOT 4 cRFORMED IN ACCORDANCE SC 7 SM DEPTH TO DATE GROUNDWATER 15' 5/23/2003 B OF A , us' 6/4/2003 9 •`P:• �',_0 13 10/15/ 4 70 •• ..TE READING CLOCK 17 :AUCHAEL E. ANDER:C :A' • TIME r' CE -4331 bx(/2003 1 3:40 12 •;•.: j dip'•.......• ` 1 '17E �:2 4:10 ;• ��� pdOTES510��a.41 3 4:10 //iA e�a�rrtw a a:aD wAllpisli re A. ess.' —7953 prof l q%odig T+ ♦THj2 w j LOT 3 0 J SRE PUW 1'-100' NET TIME. WATER LE% (MINUTES) READING 6• ao 2 1/2' L.= NET DROP (INCHES) 3 1/2- 2 7/8* 15 •. ;: 7 5:10 — 6" — .; •... •••••• 6 5:40 30 4 1/4- 1 T/-4 .B.O.H. Y 17- 718PERCOLATION 18— PERCOLATIONRATE 17.1 (MIN./INCH) PERC. HOLE DIA. 6 (INCHES) 19' TEST RUN BETWEEN 6.0 FT. AND 6.5 FT. 20 A FOUR HOUR PRESOAK WAS PERFORMED: N YES ❑ NO SOILS LOGGED BY: SUSAN OSWALT PERCOLATION TEST PERFORMED BY: NICK HEITMMAN COMMENTS: PERFORMED BY AKWWC, INC., 1, JEFFREY A. GARNESS, CERTIFY. THAT THIS cRFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE: • - • fi'''x • AI ,A.SKA.- WATER &. WASTEN VATER CONSULTANTS. INC. hUIL LUU - YLKL,UL.AIIUN ILJII LEGAL DESCRIPTION: SANDY ACRES SUBDIVISION: LOT 1-4. PERFORMED FOR: TONY BLOLIFIELD DATE: 5/23/2003 DEPTH ____ (reel) __=_ ORGANICS TEST HOLE 3 = e 9 I 10 1 11 I 12 13 I. 14J `E-•OF•q:ge 49TH A:a I^Y, 14• hO/15/04 OF [�mlm Fi11ml Aness.- C —7903 a' e O4o -_- SANDY LOAM SOIL CLASSIFICATIONS LOT UNE .L E. ANCER.:CN•,�UHTc TH13$ CLOCK 4TH12 WATER LEVEL NET DROP ' T+ .. 0 TIME . (MINUTES) READING (INCHES) —1 3 z GP I I ML 5:55 m 6• GM / CL 4 5 5/8• 3/8' LOT 4 7 LOT 3 GC 1. OL °• •°• : J ' SW MH 5 1'-100• •'• SP CH T INS SM %; OH 6 SC 7 SM DEPTH I DATE ' t GROUNDWA ER 3•"�IL e 9 I 10 1 11 I 12 13 I. 14J `E-•OF•q:ge 49TH A:a I^Y, 14• hO/15/04 OF [�mlm Fi11ml Aness.- C —7903 a' e O4o 3 6:25 — 6' 4 6:56 30 5 1/2- 1/2- 5 /2'5 6:57 6• 6 7:27 30 5 1/2* 1 /2' 15 µ)'1 .'• 16 — 'B.O.H. . C ' 17 18 19 .PERCOLATION RATE 60 (MIN./INCH) PERC. HOLE DIA. 6 (INCHES) TEST RUN BETWEEN 6.S PT. AND 7.0 -FT. 20 A FOUR HOUR PRESOAK WAS PERFORMED: E YES ❑ NO SOILS LOGGED BY: SUSAN OSWALT PERCOLATION TEST PERFORMED BY: NICK HEUMLIAN COMMENTS: PERFORMED BY AKWWC. INC.. I, JEFFREY A. GARNESS. CERTIFY THAT THIS 1/AS VERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPAL CUIDEI,.INES IN EFFECT ON THIS DATE: m LOT UNE .L E. ANCER.:CN•,�UHTc TH13$ CLOCK 4TH12 WATER LEVEL NET DROP ' T+ .. 0 TIME . (MINUTES) READING (INCHES) —1 C z 5/28/2003 1 - 5:55 m 6• Li 30 5 5/8• 3/8' LOT 4 7 LOT 3 0 J ' SITE PLAN 1'-100• LOT LING T INS 3 6:25 — 6' 4 6:56 30 5 1/2- 1/2- 5 /2'5 6:57 6• 6 7:27 30 5 1/2* 1 /2' 15 µ)'1 .'• 16 — 'B.O.H. . C ' 17 18 19 .PERCOLATION RATE 60 (MIN./INCH) PERC. HOLE DIA. 6 (INCHES) TEST RUN BETWEEN 6.S PT. AND 7.0 -FT. 20 A FOUR HOUR PRESOAK WAS PERFORMED: E YES ❑ NO SOILS LOGGED BY: SUSAN OSWALT PERCOLATION TEST PERFORMED BY: NICK HEUMLIAN COMMENTS: PERFORMED BY AKWWC. INC.. I, JEFFREY A. GARNESS. CERTIFY THAT THIS 1/AS VERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPAL CUIDEI,.INES IN EFFECT ON THIS DATE: m .L E. ANCER.:CN•,�UHTc READING CLOCK NET TIME WATER LEVEL NET DROP ' E•4331 .. TIME . (MINUTES) READING (INCHES) •.....••' 5/28/2003 1 - 5:55 — 6• .6:25. 30 5 5/8• 3/8' 3 6:25 — 6' 4 6:56 30 5 1/2- 1/2- 5 /2'5 6:57 6• 6 7:27 30 5 1/2* 1 /2' 15 µ)'1 .'• 16 — 'B.O.H. . C ' 17 18 19 .PERCOLATION RATE 60 (MIN./INCH) PERC. HOLE DIA. 6 (INCHES) TEST RUN BETWEEN 6.S PT. AND 7.0 -FT. 20 A FOUR HOUR PRESOAK WAS PERFORMED: E YES ❑ NO SOILS LOGGED BY: SUSAN OSWALT PERCOLATION TEST PERFORMED BY: NICK HEUMLIAN COMMENTS: PERFORMED BY AKWWC. INC.. I, JEFFREY A. GARNESS. CERTIFY THAT THIS 1/AS VERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPAL CUIDEI,.INES IN EFFECT ON THIS DATE: m ON-SITE WASTEWATER DISPOSAL SYSTEM CONSTRUCTION AND MATERIAL SPECIFICATIONS SUBJECT: LOT 4, SANDY ACRES SUBDIVISION GENERAL: The scope of this project includes the procurement and placement of a new 1,250 -gallon septic tank at the location shown on the Site Plan. Work also includes the construction of 2 new 56' long X 3' wide X 6' effective depth absorption trenches at the location also shown on the Site Plan. The distribution line in the trench will be placed at 2' below the existing ground surface. Total depth of the trench will be 8' below the existing ground surface. The new absorption trenches and septic tank must be placed a minimum of 100' from all private wells and any surface water in the area and 10' from the water service line proposed for the lot. A minimum of 3' of cover is required over the absorption trench and 4' of cover over the septic tank. A flow splitter valve must be placed to insure even flow from each trench. 2. Construction shall be in accordance with the approved site plan, design drawings, Municipal Permit with any special provisions or conditions, and all applicable State and Municipal Wastewater Disposal Regulations. 3. The Contractor shall be responsible for obtaining all underground utility locates and for the layout of the septic system and verification of the location of all lot lines. The Contractor must also verify the location of wells in the area and assure that the separation distances are met. 4. Unless specifically agreed otherwise, the contractor shall be responsible for final grading areas subsequently depressed from soil settling. Property owner shall be responsible for revegetation of affected areas unless specifically agreed otherwise. 5. Contractors installing wastewater disposal systems must be certified by the Municipal Department of Health and Human Services for system installations. Owners installing their own systems must receive prior approval from D.H.H.S. before beginning system installation. SEPTIC TANK INSTALLATION A new 1,250 -gallon septic tank must be procured from an approved source and installed at the location shown. 2. A septic tank is to be constructed by a certified septic tank manufacturer. Construction shall include two 4" cleanouts for pumping access. Lot 4, Sandy Acres November 17, 2005 Page 2 of 3 3. The septic tank shall be sufficiently bedded to prevent settling or shifting of the tank. 4. All standpipes on the septic tank shall extend a minimum of 12 inches above final grade. 5. Tanks installed without 4' of cover shall have a minimum of 2" of direct burial insulation. 6. A foundation cleanout shall be installed one to four feet from the building foundation. Two cleanouts are required between the tank and the drainfield. 7. Final grading over the tank shall be such that a positive slope exists away from the septic tank. DRAINFIELD CONSTRUCTION: 1. The drainfield shall be constructed to the dimensions shown on the design. The bottom of the trench shall be within 2" of level. 2. Distribution piping must be placed level with perforations down atop a level bed of drainfield rock. Rock should then be placed over the pipe to provide a minimum of 2" of cover. 3. A silt barrier or geotextile fabric must be placed between the drainfield rock and the natural soil backfill. 4. Monitor tubes must be 4" in diameter and installed at the locations shown on the design. The portion below ground must be perforated. 5. Contractor shall verify the septic tank and drainfield are a minimum 100' away from any private water wells in the area, 150' from a Class "C" Well or 200' from any community well. 6. Direct bury insulation must be placed over the distribution system if less than 3' of backfill depth is available. Finish grade over the trench must be mounded to prevent settlement or depressions. 7. Grade area surrounding the absorption trench to drain away. 8. A minimum 2' of accepting soil is required below the drainfield rock for a 5' wide trench. Contractor shall verify this condition prior to placement of the rock. All pockets of unacceptable materials must be removed and replaced. Lot 4, Sandy Acres November 17, 2005 Page 3 of 3 MATERIAL SPECIFICATIONS: Septic tanks must be constructed by a municipally approved septic tank manufacturer. 2. The following pipe materials are approved for use in septic system installations in the Municipality of Anchorage: Cast Iron (perforated and solid), ASTM D3034 or P.V.C. (perforated and solid), ASTM F810 or H.D.P.E. (perforated, but not solid) and ASTM D2662 or A.B.S. (perforated and solid). 3. Insulation shall be at least 2" thick extruded direct burial polystyrene (Dow Chemical Co. Styrofoam HI or equal). 4. Septic tank inlets and outlets shall be fitted with watertight couplings (Caulder, Fernco, or equal). 5. A permeable geotextile fabric (Typar, Mirafi or equal) must be installed between the final drain rock layer and the native soil layer. 6. All drain rock shall be .5" to 2.5 in diameter with less than 3% passing the #200 sieve. INSPECTIONS: Municipal Ordinance requires a minimum of two inspections. These inspections must be conducted under the supervision of a professional engineer registered in the State of Alaska. The first inspection must be conducted after the excavation of trenches, beds or pits and before the installation of any gravel. A septic tank may be set in place, but may not be backfilled. The second inspection must be conducted after the placement of the geotextile fabric, gravel, distribution piping, standpipes, cleanouts and insulation. No backfill should be in place at the time of inspection. Contractor shall provide a copy of all field survey layout and construction notes for use in preparing the certified as -built of the completed system. ANDERSON ENGINEERING P.O. BOX 240773 ANCHORAGE, AK 99524 522-7773 677-7766 FAX MEMORANDUM DATE: November 30, 2005 TO: Julie Makela, P.E. FROM: Mike Anderson, P.E. SUBJECT: Lot 4, Sandy Acres Subdivision Well and Septic System Permit Attached ;is the modified area map showing wells and septic systems surrounding Lot 4, Sandy Acres Subdivision. A Class A Well is in service on the property immediately to the west. The well is located more than 200' from the property lines of Lot 4. No other wells or septic systems in the area conflict with the proposed well or septic system for this lot. The proposed absorption trench system and alternate site are located slightly outside the 30' radius of the test hole on the lot. This test hole was completed during the subdivision phase of the project and was the only area where soil absorption characteristics were slower than 15 minutes per inch. We anticipate that actual conditions found surrounding this test hole will yield soils with much better absorptive characteristics. We therefore request that a condition be placed on the permit requiring the submittal of an additional test hole and percolation testing to verify soil conditions. This work can be accomplished at the time of the construction of the system and will result in a substantial monetary saving to the owner of the property. Please let me know if you have further questions. Municipality of Anchorage Development Services Department Building Safety Division On -Site Water and Wastewater Program 4700 South Bragaw St. P.O. Box 196650 Anchorage, AK 99519-6650 www.muni.orglonsite (907)343-7904 ON-SITE SEWER/WELL SUBMITTAL COMMENT SHEET To: Anderson Engineering Legal description: Sondy Acres Subdivision, Lot 4 The attached paperwork has been reviewed and is being returned for the following reasons: ❑ Original signature or stamp missing on _ ❑ Calculation error in design. _ ® Additional soils information needed. Need additional test hole(s) d pert test(s) ❑ Water monitoring results inadequate. _ ❑ Discrepancy in information submitted. _ ❑ Topographic information missing or inadequate. _ ❑ Incomplete; missing ❑ Incomplete; missing ❑ Additional adequacy test information needed. ❑ Water sample unacceptable. _ ❑ Measured/proposed distances/dimensions missing. _ ❑ Locations of all soils, percolation and water monitoring tests not shown. ❑ Proposed system too deep for soils information submitted. ❑ Well log required. ❑ Omission in narrative. ❑ Insufficient fill over tank or field._ ® Other. 1.) Please verify effective depth on site plan: 2.) Please show I Name of reviewer: Julie Makela, P.E. Date: 11/18/2005 Please supply the necessary information and re -submit your request. LEAVE THIS FORM ATTACHED TO THE PAPERWORK Municipality of Anchorage Development Services Department +� Building Safety Division On -Site Water and Wastewater Program 4700 South Bragaw St. P.O. Box 196650 Anchorage, AK 99519-6650 www.muni.orglonsite (907)343-7904 ON-SITE SEWER/WELL SUBMITTAL COMMENT SHEET To: Anderson Engineering Legal description: Sandy Acres Subdivision, Lot 4 e SA tTY The attached paperwork has been reviewed and is being returned for the following reasons: ❑ Original signature or stamp missing on ❑ Calculation error in design. _ ® Additional soils information needed. Need to show location of additional test holes/percolation tests to be done at time of construction. ❑ Water monitoring results inadequate. _ ❑ Discrepancy in information submitted. ❑ Topographic information missing or inadequate. ❑ Incomplete; missing _ ❑ Incomplete; missing _ ❑ Additional adequacy test information needed. ❑ Water sample unacceptable. _ ❑ Measured/proposed distances/dimensions missing. ❑ Locations of all soils, percolation and water monitoring tests not shown. ❑ Proposed system too deep for soils information submitted. _ ❑ Well log required. ❑ Omission in narrative. _ ❑ Insufficient fill over tank or field._ ® Other. Please verify effective depth on area plan. Name of reviewer. Julie Makela. P. E. Date: 12/7/2005 Please supply the necessary information and re -submit your request. LEAVE THIS FORM ATTACHED TO THE PAPERWORK Municipality of Anchorage ��b' •br �- Development Services Department Building Safety Division Onsite Water and Wastewater Program , b 4700 Bragaw Street P.O. Box 196650 Anchorage, AK 995196650 www.muni.org/onslte (907) 343-7904 CERTIFICATE OF ON-SITE SYSTEMS APPROVAL FOR A SINGLE FAMILY DWELLING Parcel I.D. 015-501-43 COSA # ftPO J 8 &- Expiration Date: 1. GENERAL INFORMATION Complete legal description Lot 4. Sandy Aces Subdivision Location (site address) 10674 LOW circle Current Property owner(s) Marianne Braund Day phone 317'58" Mailing address SUS Fairweather Dive Andwrage, AK 99518 Lending agency Day phone Mailing address Real Estate Agent Day phone Mailing Address Unless otherwise requested, COSA w771 be hold by DSD forpickup. 2. NUMBER OF BEDROOMS: Four (4) 3. TYPE OF WATER SUPPLY: TYPE OF WASTEWATER DISPOSAL: Individual Well Individual On-site Individual Water Storage ❑ Individual Holding Tank ❑ Community Class Well ❑ Community On-site ❑ Public Water System ❑ Public Sewer ❑ The Municipality of Anchorage Development Services Department (DSD) issues Certificates of On -She Systems Approval (CASA) based only upon the representations given in paragraph 4 by an independent professional civil engineer registered in the State of Alaska. Certificates of OnSfte Systems Approval are required for the transfer of title (except between spouses) for properties served by a single-family on-site wastewater disposal and/or water supply system. DSD also issues COSAs upon request to homeowners. Certificates of Onsite Systems Approval are valid for 90 days from the date of issue for properties served by a private or Class C well and may be reissued with new water sample results. (Certificates may be reissued for a period of up to one year with valid water samples.) Certificates are valid for one year for properties served by Class A or B wells or a public water system. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. 4. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, 1 verify that my investigation, based on procedures outlined in the Certificate of Onsite Systems Approval Guidelines for this application, shows that the on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate for the number of bedrooms and type of structure indicated herein. 1 further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation. Name of Finn Anderson Engineering Phone 522-T173 Address P.O. Box 240773 Anchorage, AK 99524 Engineer's Printed Name Michael E. Anderson, P.E. 5. DSD SIGNATURE Approved for bedrooms. Disapproved. Date 12/7r2W6 Conditional approval for bedrooms, with the following stipulations: VVJ/1 161I1U M151 A Arsenic Aavisory Septic System Advisory Maintenance Agreements Well Flow Advisory Supplemental Engineer's Report Nitrate Advisory Other BY: `� Original Certificate Date: .Z 11—D 6 ra« 11MM Municipality of Anchorage ' Development Services Department `•: Building Safety Division On-Sfte Water 6 Wastewater Program 4700 Bntgew Street P.O. Box 196850 Anchorage, AK 9951943650 www.muni.orglonsne (907) 343-7904 CERTIFICATE OF ON-SITE SYSTEMS APPROVAL CHECKLIST Legal Description: Lot 4. Sandy Acrm Subdivision Parcel ID: WS -5011-43 A. WELL DATA Wen type PYvats H A, B, or C provide PWSID 1t _ Wed Log (YM) Y Date completedONA05 Sanitary seal (YM) Y Wires property protected (YIN) Y Total depth 1t7 R Cased to 117 fl. Casing height (above ground) >24 in. FROM WELL LAG AT INSPECTION Date of test 3normoe Static water level e3 ft. 1l Well production 2e g.p.m. g.p.m. WATER SAMPLE RESULTS: Coliform a colonieal100 mL Nitrate No mgli. Other bacteria 2 colonies/100 ml- Anionic: LArsenic: WD mgA Date of sample: al21rA0e Collected by: F. LeOmm B. SEPTICMOLDING TANK DATA Tank TypelMatadal SepucJSted Date installed 2r WON Tank sae i= gal. Number of Compartments Two Cleanouts (YM) Y Foundation deanout (YM) Y Depression over tank (YM) N High water alarm (Y/N) N Date of pumping New Co o"cu n Pumper C. ABSORPTION FIELD DATA Date installed 2r2S-V2= Soil rating (g.p.d.Ae or fefbd1rm) as OP0W Symon type Dssp Tnndr Length 112 fL vylft 3 R. Gravel below pipe e R Total depth 1211 h, Elfabsorption area 1.34 tt7 Monitoring tube Y Depression over field N Data of adequacy Last New cw0L Results (PasslFail) For _ bedrooms Fluid depth in absorption field before test in. Water added gal. New depth in. Elapsed Time min. Final fluid depth in. Absorption rate >= g.p.d. Any rejuvenation beebrant (past 12 rw.) (YM 6 type) N N yea, give date D. LIFT STATION Date installed Size in gallons 'Pump on' level at _ in. 'Pump ofr level at _ in. Dattxn Cycles tested E. SEPARATION DISTANCES SEPARATION DISTANCES FROM WELL ON LOT TO: Septic tankfitft station on lot >iW Absorption field on lot >1W Public sewer main WA Sewer hreptlC service line >25 Manhole/Access (Y/N) High water alarm level at in. Meets alarm 6 circuit rapusarnents? On adjacent lots On adjacent lots >iw Public sewer manhokweanout WA Holding tank NIA Animal containment areas None ManumAw*n i atcerete storage areas None SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK ON LOT TO: Building foundation >s' Property line >S Water main >10, Water service line >to' Surface water >1W Weds on adjacent kits >iw SEPARATION DISTANCE FROM ABSORPTION FIELD ON LOT TO: Property line »a Building foundation »e' Water main >te' Water Service Nne »a Curtain drain Now Noted F. COMMENTS: G. ENGINEER'S CERTIFICATION Surface water >Iw Wells on adjacent kts >1W I cer* that I have determined through field ktspacbbw and review d Murritdpat records that the above systems are in cm* mance with MOA COSA guldelines lo affect on this date. Engineer's Printed Name Michael E. Anderson, P.E. Data 127r2o05 Driveway, pargnghghide storage >2S COSH Fee $ �� f .6D Waiver Fee $ Date of Payment l plcy lob Date of Payment Receipt Number ?qAq Receipt Number (Rev. t tm! ) SGS ReEN 1061874001 Client Name Anderson Engineering Project Name/a Lot 4 Sandy Acres Client Sample ID Lot 4 Sandy Acres Matris Drinking Water All Dates/Times ore Alaska Standard Time Printed Date/Time 08292006 8:01 Collected Date/Time 08212006 13:00 Received Date/rime 08212006 13:25 Technical Director Stephen C. Ede Sampie Remarks: ICP/MS Arsenic pa a ctcr Allo, -able Results PQL Units Method Conwiner ID Limits Prep Date Analysis Date but Metals by ICP/MS Arsenic Waters Department Nitrate -N Microbiology Laboratory Total Coliform ND 5.00 ND 0.100 <2 00, No Coli ug/L EP200.8 m8/L EPA 353.2 C (<10) 0822/06 0825/06 Mll B (<IO) col/IOOmL SK1209222O A (<1) 0821/06 ALR 0821/06 TLF 1 11=40' 2004-148 SANDY ACRES SUBDIVISION LOT 4 44,229 S.F. [,`-Pli-T-414FAW 0J� 44.E 0 N 89.56'15"E 114.94' 15' T. k E. do GAS ESWr. WELL I I I I 10' T. do E. ESMT. I I I I I ENCROACHMENTS EXIST EXCEPT AS INDICATED. I I I SEFIM SYSTEMS I I I A I + I APPS ON THE RECORDED SUBDIVISION PLAT. PHONE 248-5454 UNDER NO CIRCUMSTANCES SHOULD ANY DATA HEREON BE USED FOR CONSTRUCTION OR FOR GRID DATE I 12/7/2006 11`3 WI F.B. IW 8 `aI SAS4 Iz 0 as N .*d t o IJI I '8 a 64.8' z I �� 0J� 44.E 0 N 89.56'15"E 114.94' 15' T. k E. do GAS ESWr. WELL (APX) AS -BU I LT I HEREBY CERTIFY THAT I HAVE SURVEYED THE PROPERTY DEPICTED ABOVE AND THAT NO GASTALDI LAND ENCROACHMENTS EXIST EXCEPT AS INDICATED. SURVEYING, LLC R IS THE RESPONSIBILITY OF THE OWNER TO JEFF A. GASTALDI, R.L.S. A ^y~ c T � ANCHORAGE, ALASKA 99502 (APX) AS -BU I LT I HEREBY CERTIFY THAT I HAVE SURVEYED THE PROPERTY DEPICTED ABOVE AND THAT NO GASTALDI LAND ENCROACHMENTS EXIST EXCEPT AS INDICATED. SURVEYING, LLC R IS THE RESPONSIBILITY OF THE OWNER TO JEFF A. GASTALDI, R.L.S. DETERMINE THE EXISTENCE OF ANY EASEMENTS, 4726 WEST 88TH AVENUE COVENANTS OR RESTRICTIONS WHICH DO NOT ANCHORAGE, ALASKA 99502 APPS ON THE RECORDED SUBDIVISION PLAT. PHONE 248-5454 UNDER NO CIRCUMSTANCES SHOULD ANY DATA HEREON BE USED FOR CONSTRUCTION OR FOR GRID DATE 2537 12/7/2006 ESTABLISHING BOUNDARY OR FENCE LINES. ANCHORAGE RECORDING DISTRICT, ALASKA F.B. JOB NO. 06-04 SAS4 NOTE: NO CORNERS SET THIS DATE BUILDING DETAIL SCALE: 1"=20' OF • ��••.� 49Th •9 . a • Jeffery ;waldl : o` Alr .�Ar . LS— 091 : �°Ar iPa •...� .�?p. f..`.• �p .