Loading...
HomeMy WebLinkAboutDEBORA BLK C LT 8V, I f, I �, ipso 01S iotl b13o GREA , ER ANCHORAGE AREA BOR.. jGH � I�1 Department of Environmental Quality P Y 3330 C Street Anchorage, Alaska 99503 INSPECTION REPORT ON-SITE SEWAGE DISPOSAL SYSTEM NAME-� MAILING ADDRESS -- A'S'E �. n99s7y _ PHONE p"� /C5S LOCATION �2 LEGAL DESCRIPTION. /7 L ASL GAJ SEPTIC TANK: DISTANCE%`f / n, NUMBER L FROM WELL �MANUFACTURER � Rei MATERIAL COMPARTMENTS INSIDE LENGTH 8y / INSIDE WIDTH LIQUID DEPTH LIQUID CAPACITY LeGALLONS. TILE DRAIN FIELD: / / TOTAL LENGTH -, DISTANCE FROM WELL /CS FOUNDATION NEAREST LOT LINE /A OF LINES `� / NUMBER OF LINES / DISTANCE BETWEEN LINES TRENCH WIDTH 3 IN. TOTAL EFFECTIVE ABSORPTION AREA 3/n SQ. FT. LENGTH OF EACH LINE S,/ DEPTH OF FILTER DEPTH: TOP OF TILE TO FINISH GRADE MATERIAL BENEATH TILE IN. ABOVE TILE IN. WELL: TYPE BUILDING FOUNDATION CESSPOOL APPROVED DISTANCES: _ CONSTRUCTION NEAREST / NEAREST LOT LINE, SEWER LINE OTHER SOURCES DISAPPROVED REMARKS INSTALLED BY: /11_� SEWER LINE DEPTH: PIPE MATERIAL: LOT SLOPE: REMARKS: Form EQ -032 DEPTH DISTANCE FROM: SEPTIC ��jj[[JJ/ SEEPAGE / TANK, SYSTEM /n'r f'Ie7el � V DIAGRAM OF SYSTEM DATE "Y %//U APPROVED G.A.A.B. a rlur4 ICI nL_ I T',' CAF= f=lrj .H 11F?HGE X/"DEPARTMEFIT �HEALTH AND ENVIRONMENTAL?OTECTION 122516 E. TUDOR P.D., ANCHORAGE, AK. 90507276-2221 /,Dvo& CA PERMIT PUJ. ( 76526 rJ—ITE cEWEFt' F'EF=:r�1 I TI•10 /r:' APPLICANT JIM WFATHERBY GEN DELIVERY E. P,. 99577 4-9551 LOCATION MERCY DRIVE LEGAL LS BC DEBORAH SUE LOT SIZE 10275 SQUARE FEET TYPE OF SOIL ABSOR:BTION SYSTEM IS: TRENCH MAXIMUM NUMBER OF BEDROOMS = 3 SOIL RATING (SO FT/ER)= 100 THE REQUIRED SIZE OF THE SOIL ABSORPTION SYSTEM IS: C•EF•TH= 12 LEr4G1FF-1= ZEAL GFS'fA% EL GEF•TH= THE LENGTH DIMENSION IS THE LENGTH (IN FEET) OF THE TRENCH OR DRAINFIELD. THE DEPTH OF A TRENCH OR PIT IS THE DISTANCE BETWEEN THE SURFACE OF THE GROUND AND THE BOTTOM OF THE EXCAVATION (IN FEET). THERE IS NO SET WIDTH FOR TRENCHES. THE GRAVEL DEPTH IS THE MINIMUM DEPTH OF GRAVEL BETWEEN THE OUTFALL PIPE AND THE BOTTOM OF THE EXCAVATION (IN FEET). F=:E�11_1 I F= EC• QEF T I C TFIrdFC S; I LE= 1 y y i GRLL0r+i55 BACKFILLING OF ANY SYSTEM WITHOUT FINAL INSPECTION AND APPROVAL BY THIS DEPARTMENT WILL BE SUBJECT TO PROSECUTION. MINIMUM DISTANCE BETWEEN A WELL AND ANY ON-SITE SEWAGE DISPOSAL SYSTEM IS 100 FEET FOR: A PRIVATE WELL OR 200 FEET FOR A PUBLIC WELL. SPECIFICATIONS AND CONSTRUCTION DIAGRAMS ARE AVAILABLE TO INSURE PROPER INSTALLATION. F'EF:M I T 'ti�Y-IL I Lti F-L1F: OrJE "r'ERF' F= Ft:0r-1 I E:SL.1E I CERTIFY THAT 1: I AM FAMILIAR. WITH THE REQUIREMENTS FOR ON-SITE SEWERS AND WELLS AS SET FORTH BY THE MUNICIPALITY OF ANCHORAGE. 2: I WILL INSTALL THE SYSTEM IH ACCORDANCE WITH THE CODES. _. I UNDERSTAND THAT THE ON-SITE SEWER SYSTEM MAY REQUIRE ENLARGEMENT IF THE RESIDENCE IS REMODELED TO INPLUDE MORE THAN 3 BEDROOMS. SI IS r I VVV ✓�� , 0 & E GEO , CHNI CAL & DEVEL� MENT CO. Boz 90, Davis St., Eagle River, Alaska 99577 694-2774 or 686-2280 Russell Oyster Earl Ellis 694-2774 SOIL LOG 688-2280 Soils & Foundations Land Development Performed for: Name:_C��. ��.M ��p.�c-�-4�SLy5Y Tel. No. Mailing Address: Legal Description: T1%i84aa'A Depth (feet) Soil Characteristics 0- 1 2 3 4 5 6 7 8 0 10 \41 (y` o ,moo �v.2 �1r� Se•vs. 11 G� - c7q.t�Y c6cUv.L�� W,rh Cac3Bt�c5 A.Jfl r�� . ��Duy,pSJLS 'fid 'z LA a[Lj'+ti 0�1gv. 13 1L 15 16 Ground Water Encountered: Yes No If yes, what depth Proposed Installation: Seepage Pit Drain Field Comments: %V Performed by: -1-" Date' 1a1'7r h.7� p/sem � u4�FSl� hlVNIICWAUTY OF PD,CHORAGE cert: OF HcALTIi r. M -W DRILLING, Inc. _. EM'IBCN!:'.:vTAI P^JTEaICN P.O. Box 4-1224 - 1310C International Airport Road (907) 274-4611 FEAR 15 ANCHORAGE, ALASKA 99509 RECEIVED DRILLING LOG Well Owner Jim b;eatherbv Use of Well Dor? Location (address of: Township, Range, Section, if known; or distance main roars LII. B1k C. Deborah Subdiv., Fa River Size of casing---6---Depth of Hole 75 feet Cased to 75 feet Static water level 63 ft. ' ('a'bove) (below) land surface. Finish of well (check one) open end ( ); Screen ( ); Perforated ( ). Describe screen or perforation None Well pumping test at 5 gallons per (Wi)' (minute) for----I--hours with - 100L ft: of drawdown from static level. Date of completion 24 Feb 76 WELL LOG Depth in feet from ground surface Give details of formations penetrated, size of material, color and hardness TO .2 Casina STickun TO 4 Organics g TO 10 Clayey Gravel 101 TO 11 Silty Grsvel 11 TO 16 C1;\1?Py Gr Ayol 1r TO 1B RoulAer 1 FITO 97 c�hblar TO ao Silty gAn•1 Fn TO A5 S�e9�• C r,wrt e ... t �� TO T1 rr^...,lir f t,�• TO -TO- O 0- O 0- O C..; NE"S. 81-i L 3 2 2 —STATE MIJt�F I iC I C�iL I TY OF RNCHG�RRGE DEPARTMENT ( HEALTH AND ENVIRONMENTAL )TECTION 2510 E. TUDOR. RD., ANCHORAGE, AK. 99507 276-2221 LJELLL F"EFZM I T PERMIT N0.C76022) TIM WERTHERBY GEN LOCH11ON MERCY DP, LEGAL L8 BC DEBORAH LOT SIZE 10000 SOFT MINIMUM DISTANCE FROM WELL TO ANY SYSTEM IS 100 FT FOR A PRIVRTEWELL WELL LOGS MUST BE RETURNED TO THE COMPLETION. DEL E. R. 6949551 SEPTIC TANK./PACKRGE PLANT OR SOIL ABSORPTION AND 200 FT FOR R PUBLIC WELL. DEPARTMENT WITHIN 30 DRYS OF THE WELL SPECIFICATIONS AND CONSTRUCTION DIAGRAMS ARE AVAILABLE TO INSURE PROPER INSTALLATION. I CERTIFY THAT I AM FAMILIAR WITH THE REQUIREMENTS FOR ON-SITE SEWERS AND WELLS AS SETFORTH BY THE MUNICIPALITY OF ANCHORAGE AND WILL INSTALL IN ACCORDANCE WITH THE CODE. /I ) A n SI I 1 DATE. °Z/ T,�� A 1 4 M 5. LEGAL DESCRIPTION DATE RECEIVED STREET LOCATION INSPECTION APPOINTMENTS 4 6. TYPE OF RESIDENCE n SINGLE FAMILY TIME TIMEn' TIME ❑ MULTIPLE FAMILYTwo on LID rt'N 1'.�n- lY1ff 14(190 ItL INDIVIDUAL- DATE DATE L7Z DATE ❑ PUBLIC UTILITY INSPECTOR INbI`LUIUH INSPECTOFj� XINDIVIDUAL/ON-SITE" /_ /) EAR ON-SITE SYSTEM WAS INSTALLED. ❑ PUBLIC UTILITY ''11 n T -i NOTE: THE INSPECTION FEE MUST ACCOMPANY EACH REQUEST BEFORE PROCESSING CAN BE INITIATED. - CcLLS retia rn� yaatLMUNICIPALITYOFANCHORAGE 'ICIPALITY OF ANCHORAGE DEPT. OF HEALTH & DEPARTMENT OF HEALTH & ENVIRONMENTAL PROTECTIOWNVIRONMENTAL F;,OTECTION 1 ` 825 L Street . Anchorage, Alaska 99501 JUL 1 1981 L.L o ENVIRONMENTAL SANITATION DIVISION 1Ge 01-t-12—Lk to Telephone 264-4720 Sl APPROV R C DREU FOR L Ob%1WUAL WATER AND SEWER FC DI RECTIONS: Complete all parts on page 1. Incomplete requests will not be processed. Please allow ten 110) days for processing. 1. PROPERTY OWNER PHONE MAILING ADDRESS /1 / l7 fdifferent PROPERTY RESIDENT (if from above) V PHONE no.. 2. BUYER Fi /A VIP`D MAILING ADDRESS //ll rr �V ' C 3. LENDING INSTITUTIONPHON MAILING ADDRESS ,f e. REALTOR/AGENT PHONE, MAILING ADDRESS M 5. LEGAL DESCRIPTION STREET LOCATION 4 6. TYPE OF RESIDENCE NUMBER OF,BEDROOMS SINGLE FAMILY ❑ One ❑ Four ❑ Other 1:1Five ❑ MULTIPLE FAMILYTwo ❑ Three ❑ Six 7. WATER SUPPLY ItL INDIVIDUAL- ' ATTACH WELL LOG. A well log is required for all wells drilled ❑ COMMUNITY since June 1975. For wells drilled prior to that date, give well ❑ PUBLIC UTILITY depth (attach log if available.) 8. SEWAGE DISPOSAL SYSTEM XINDIVIDUAL/ON-SITE" /_ /) EAR ON-SITE SYSTEM WAS INSTALLED. ❑ PUBLIC UTILITY NOTE: THE INSPECTION FEE MUST ACCOMPANY EACH REQUEST BEFORE PROCESSING CAN BE INITIATED. 72010 (Rev. 6/79) w U 72010 (Rev. 6/79) THIS SIDE FOR OFFICIAL USE ONLY 1. TYPE OF RESIDENCE ❑ SINGLE FAMILY ❑ MULTIPLE FAMILY NUMBER OF BEDROOMS ❑ ONE ❑ THREE ❑ FIVE ❑ OTHER ❑ TWO ❑ FOUR ❑ SIX 2. WATER SUPPLY ❑ INDIVIDUAL ❑ COMMUNITY ❑ PUBLICUTILITY Connection Verified PERMIT NUMBER DEPTH OF WELL DATE DRILLED LOG RECEIVED 3. SEWAGE DISPOSAL SYSTEM ❑INDIVIDUAL/ON-SITE ❑PUBLICUTILITY Connection Verified PERMIT NUMBER DATEINSTALLED 1(� —�(o INSTALLER ❑Septic Tank or ❑Holding Tank Size: I 00o If Tank is homemade give dimensions: SOILS RATING TYPE OF TANK MANUFACTURER TOTAL ABSORPTION AREA MATERIAL v� 4. DISTANCES WELL TO: Septic/Holding Tank Absorption Area Sewer Line Nearest Lot Line Absorption Area to nearest Lot Line 5. COMMENTS r EVAPPROVED FOR Z/ BEDROOMS LT CONDITIONAL APPROVAL (letter must company certificate) ❑ DISAPPROVED DATE --)9C BY y1^/, ` C Z�fi 72010 (Rev. 6/79) CHEMICAL & GL_LOGICAL LABORATORIES ILPF ALASKA, INC. TELEPHONE 19071-2794014 ANCHORAGE INDUSTRIAL CENTER . � 274-3364 SW3 9 Street Drinking Water Analysis Report for Total Coliform Bacteria '" a TO BE COMPLETED BY WATER SUPPLIER TO BE COMPLETED BY LABORATORY WATER SYSTEM: I.D. NO. Water SyaNm Name ( t It No. Meiling Address •� City j State Zip Code = SAMPLE DATE: , Mo. Day Year SAMPLE TYPE: ❑ Routine ❑ Check Sample (for routine sample with lab ref. no. t ❑ Treated Water ❑ Special Purpose ❑ Untreated Water SAMPLE Time Collected No. LOCATION - Colleetad By 3 4I S Analysis shows this Water SAMPLE to be: ❑ Satisfactory ❑ Unsatisfactory ❑ Sample too long in transit: sample should not be over 48 hours old at examination to indicate reliable results. Please send new sample. Date Received Time Received Analytical Method: ❑ Fermentation Tube ❑ Membrane Filter Lab Ref. No. Result' Analyst l I � i m J m •No or C010 r5/100 W a No. or Pe4ere W1,om 06-1220(b) BACTERIOLOGICAL WATER ANALYSIS RECORD - aae. 1979 Dale CoNaelad Source READ INSTRUCTIONS ' A.M. tale RecMrM Tlme ReoNeed P.m. Lao. No. Preturrrott" 1 10M 1 10.1 1 10.1 1 10.1 1 10.1 1 ..ad O.ImI BEFORE EMO arot. 24 heura, wroth 49 hours, COLLECTING SAMPLE Mwaple Tlea R.O.", 10mi Tub" PwtNwrrow 19rrd Parttar Membrane raw, Direct Count CWlrermnppnl Verification, LTO BOB Final MamNana Filter Raal ltz / " Ca117orrn/18"1 Bewailed NY �.• Dale t TN.e• P.m. r r-41 Beatrice ribby Box 187 Mercy Drive Eagle !Uver, Alaska 99577 MUNICIPALITY OFANCHORAGE DEPT. OF H`_ -.LTH & DAVID A. SLENKAMPENVIRONMENTAL i.,CTCCTION MECHANICAL694-9055 ENGINEER JUL n 198 July 5, 1981 RECEIVED Dear Mrs. Ilihby, Reference: Lot 8C: Debra Subdivision NUUUu :.i,,i U, CIVIL I Nt IN, LIt 694 2979 A sewer system adequacy test was performed on the system lbCaL,•.1 on the referenced property as you requested. The septic tank w.,,s pumped and verified to have a capacity in excess of 1100 gallol::. The absorption trench was tested by a continuous flow of 311 gallons of water over a 24 hour period without any rise in tho water level in the sump at the end of the trench. It can be concluded from this test that the waste water dispo;;,! system s(�rvinq the two bedroom residence located on this propc7:v is currently functioning adequately. however it cannot be guaranteed against subsequent failure. If we c.l.. I..• of I art hor assistance, please do not hesitate to c, l : . Sincor,. I ,•, 10 I'Wl' A. :711A171•:I:, I .I:. Municipality of Anchorage Department of Health and Environmental Protection Chugiak :::,,lle Itivljt Realty ATTENTILII:: hell t:il>b:: SR6 196X EAGLE RIVER, ALASKA Department of Health and Environmental Protection 2510 East Tudor Road Anchorage, Alaska 99507 276-2221 March 1, 1976 Mr. and lira. James Weatherby General Delivery Eagle River, Alaska 99577 Dear lir. and Mrs. Weatherby: It has come to our attention that your sewage disposal system on Lot 8 Block C Deborah Subdivision_does not contain a septic tank. It is now requ zed by law that you install a septic tank and we feel that it is reasonable to request that you do so by June 30, 1976. Also, since you mentioned that the cesspool is approximately ten (10) years old we would request that we test its percolation rate at the time of septic tank.installation. If you should decide to sell, this operation would have to be done before the sale of the home. Thank you for your co-operation and if you have any questions, please contact us at 276-2221, extension 283. Since, rhlb>�aL4�//�/ Robert P. Neale lam` Principal Environmental Control officer �f RPN/ljh , C/ `��Z);Jt`' Department of health:and Environmental Protection 2510 East ?"or Road Anchorage, Alaska 99507 276-2221 I:arch 1, 1976 1:r. and Hrs. James Weatherby Cenral Delivery Eagle River, Alaska 99577 Dear Fir. and Mrs. Weatherbys 4.1 It has come to our attention that yo-jr sewage disposal system on Lot 0 Block C Deborah Subdivision does not contain a septic tank. It is now requ ne y lWv that you install a septic tank ani we feel that it is reasonable to request that you do so by June 30, 1976. Also, since you nentioned that the cesspool is approximately tan (10) years old we mould request that we test its percolation rate at the time of septic tank installation. If you should decide to sell, this operation would have to be done before the sale of the, bo ----e. Thakl: you for your co-operation and if you have ary questions, please contact us at 276-2221, extension 203. Sincerily, Robert P. dleale Principal environmental Control officer TPa/ljh