Loading...
HomeMy WebLinkAboutDEBORA #4 LT 23OSO oz.( K.0 o00 NAME Gt"1TER ANCHORAGE AREA BOROI"'aH r HEALTH DEPARTMENT N? 254 .� 327 EAGLE ST. ANCHORAGE, ALASKA 99501 279-2511 INSPECTION REPORT ON-SITE SEWAGE DISPOSAL SYSTEM MAILING ov/-).r .91,11 LOCATION�1�. V5r LCCA/ LEGAL DESCRIPTION SEPTIC TANK: / NUMBER OF DISTANCE FROM WELL / a MATERIAL CONCdt�� COMPARTMENTS LIQUID CAPACITY Z��GALLONS. INSIDE LENGTH % /�:! INSIDE WIDTH / // DEEPTH S SEEPAGE SYSTEM: SEEPAGE PIT: NUMBER OF PITS / OUTSIDE DIAMETERy OR WIDTH �, LENGTH -��', DEPTH LINING MATERIAL Gp C -X SX6�� . DISTANCE FROM WELL �� ' BUILDING FOUNDATION -E'& '7" - NEAREST LOT LINE �a ' TOTAL EFFECTIVE ABSORPTION AREA (WALL AREA) SO. FT. TILE DRAIN FIELD: / i TOTAL LENGTH 3y i DISTANCE FROM WELL , FOUNDATION , NEAREST LOT LINE �V , OF LINES- NUMBER INES NUMBER OF LINES / / DISTANCE BETWEEN LINES TRENCH WIDTH 41 JN. TOTAL EFFECTIVE ABSORPTION AREA Ll' SO. FT. LENGTH OF EACH LINE DEPTH: TOP OF TILE TO FINISH GRADE o2 DEPTH OF FILTER MATERIAL BENEATH TILE__A�_IN. ABOVE TILE WELL: / DISTANCE FROM/ WATER TYPE Od DEPTH , BUILDING FOUNDATION. �A � SAMPLE ✓Q NEAREST iNEAREST 4� SEPTIC / SEEPAGE ��0/OTHER LOT LINE , SEWER LINE , TANK �% , SYSTEM CESSPOOL , SOURCES— DISTANCES: OURCES— DISTANCES: DATE ice" iy�� ......v .....:... .••r :I lir` DATE ice" iy�� GAAB-IID-2 GREATEI�ANCHORAGE AREA,^�LLDROUGH IIEALTFI DEPARTMENT • 327 Eagle St. Anchorage, Alaska 99501 279.2511 SEWAGE DISPOSAL SYSTEM - APPLICATION & PERMIT NAME OF APPLICANT. RESIDENCE ADDRESS LEGAL DESCRIPTIO Case No. S' y,? dzl•/Z n (9Y aue MAILING ADDRESS ��• PHONE NO. LOCATION OF INSTALLATION ' /1 2 77 Y"t, i -_-±rG/ APPLICATION TO INSTALL: SEPTIC TANKLL SEEPAGE PIT , DRAIN FIELD , OTHER TO SERVE THE FOLLOWING FACILITY 1 -`Z -j -p FINANCED THROUGH SeF TO BE INSTALLED BY Sel� PERCOLATION TEST RESULTS /47/AIJTICIPATEO DATE OF COMPLETION BELOW TO BE FILLED OUT BY HEALTH DEPARTMENT THIS IS TO SERVE AS X" r=' , PERMIT TO INSTALL A AS DESCRIBED BELOW. SIZE OF UNIT TO BE SERVED 3 LYY`LC7't� SEPTIC TANK SIZE TVDC errvarc ARrA/Jrsf'C67r?— TVOF DISTANCES: �,,,` //- /S (Z'L111taen A'&k - s ld�cl a/LF}tG.t. Tom- - S'D /o t � p/titcl/� � tom- Gtn C HEALTH AUTHORITY OR LICENSED DESIGNER I certify that I am familiar with the requirements of Greater Anchorage Area Borough Ordinance No. 28-68 and that the above described system is in accordance with said code. w /� •/1 L� /S/ c . DATEjl:�- 17 /�U APPLICANTS SIGNATURE U6�Qtc �'! TO F R O M SUBJECT I/ 3 /� i�� J -L- DATE MESSAGE 41' ey 0 ` C �4.1t�51GNE0 REPLY SIGNED DATE aedFoann 04S472 SIND PARTS t AND a INTACT - POLY PAK r50 SETS) 4P472 PART ] WILL RE RETURNED WITH REPLY. DETACH AND FILE FOR FOLLOW-UP F�.';RSA.TER ANCHORAGE AREA. BOROUGH( HEALTH DEPARTMENT 327 EAGLE STREET ANCHORAGE, ALASKA 99501 Performed For U). _M I NtC6 Legal Description: Lot-Qa—Block buw This Form Reports a: Soils Log 1/ Depth Feet Soil Characteristics _ Depth To B20 Net Drop 1 r Encpllent 9� or Gut Z— Gw poss16 sK tctenf %R- backp:lf rIJLk9Ia1. 61ha 3 GuS Sec+ton k" k l3k 4 Rock corrknf wt#k san 5 &W 4 st(t n%a}a1x; oscu611 srna(( aount o� c,( m �( 6- TTua �e tort 60145 inu e GFA tdenittebetf;m 44iah tcPPeR c-hox. GrK S •seai-ton 1 '34.111 ktq h GM tock Con-[en'I- bA P-oci. 9 5t -2.e. deAwuses. Mace, 10 sand -f 1511+ Pp,.W-nf. Date Performed 8 CASE 0 %%3 %O fest Location Sketch Was Ground Water Encountered? y(p s0 If Yes, At What Depth Reading Date Gross Time Net Tire Depth To B20 Net Drop erco a ion a inu e rroposec Installation: Seepage Pit V Drain Field Depth Of Inlet Z" Deptn To Bottom Of Pit Or Trench COMMEI7TS: Z' c -w !eW RS /MerA 316w -*9 Gm ra) 156 C 79r v Test Performed By:_ }7e e -co Data Certified Dateto %.....� . p �n s DATE RECEIVED r INSPECTION APPOINTMENTS R��D c�6� �IUE12 TIME - TIME SINGLE FAMILY TIME ❑ MULTIPLE FAMILY Three ❑ Six 7. WATER SUPPLY INDIVIDUAL' "C/hI,J /S ATTACH WELL LOG. A well log is required for all wells drilled COMMUNITY 1111 YN,E F1Lf,$ since June 1975. For wells drilled prior to that date, give well ❑ PUBLIC UTILITY DATE DATE DATE - INSPECTOR INSPECTIOn INSPECTO MUNICIPALITY OF ANCHORAG2 MUNICIPALITY OF ANCHORAGE DEPT. OF H'aLTI I :, DEPARTMENT OF HEALTH f4 ENVIRONMENTAL PROTECTIQt}.p/IRONMENTr',L 7� ::i`CTION 825 L Street • Anchorage, Alaska 99501 0*-- % I9"I ENVIRONMENTAL SANITATION DIVISION ..AN Telephone 264.4720 R E C E D E D REQUEST FOR APPROVAL OF INDIVIDUAL WATER AND SEWER FACILITIES- DI RECTI ONS: Complete all parts on page 1. Incomplete requests will not be processed. Please allow ten (10) days for processing. 1. PROPERTYOWNER AAM TER PHONE o -9322- MAILING ADDRESS 1V5 i LaeP 4o 646LC 12 f9Y77 4qox -T0,*A;i PROPERTY RESIDENT (it different from above) PHONE S 2. BUYER PHONE .5fE116 EK VAJ MEND N -1333 -.A75 MAILING ADDRE !71 ,5,,, /� f0 c 9T0 3. LENDING INSTITUTION PHONE 5cwlia A4ridy.4ze 2 - 40760 MAILING ADDRESS f N H '' Sr, ee 4. REALTOR/AGENT PHONE MAILING ADDRESS 5. LEGAL DESCRIPTION 1-07-9,3 _0Er3oQ,4 Sk a t r ty z-ou T+ �-- STREET LOCATION 4s JUM>N1(Q L�aP R��D c�6� �IUE12 6. TYPE OF RESIDENCE NUMBER OFBEDROOMS SINGLE FAMILY 13 One ❑ Four ❑ Other Ej Two ❑ Five ❑ MULTIPLE FAMILY Three ❑ Six 7. WATER SUPPLY INDIVIDUAL' "C/hI,J /S ATTACH WELL LOG. A well log is required for all wells drilled COMMUNITY 1111 YN,E F1Lf,$ since June 1975. For wells drilled prior to that date, give well ❑ PUBLIC UTILITY depth (attach log if available.) Is. SEWAGE DISPOSAL SYSTEM XINDIVIDUAL/ON-SITE" q I YEAR ON-SITE SYSTEM WAS INSTALLED. ❑ PUBLIC UTILITY NOTE: THE INSPECTION FEE MUST ACCOMPANY EACH REQUEST BEFORE PROCESSING CAN BE INITIATED - 72010 (Rev. 6/79) ` 1 s�JT!�a THIS SIDE FOR OFFICIAL USE ONLY 1. TYPE OF RESIDENCE ❑ SINGLE FAMILY ❑ MULTIPLE FAMILY NUMBER OF BEDROOMS ❑ ONE ❑ THREE ❑ FIVE ❑ OTHER ❑ TWO ❑ FOUR ❑ SIX 2. WATER SUPPLY ❑ INDIVIDUAL ❑ COMMUNITY ❑ PUBLIC UTILITY Connection Verified PERMITNUMBER DEPTH OF WELL DATE DRILLED LOG RECEIVED 3. SEWAGE DISPOSAL SYSTEM ❑INDIVIDUAL/ON -SITE ❑PUBLIC UTILITY Connection Verified PERMIT NUMBER DATEINSTALLED INSTALLER ,. ❑Septic Tank or ❑Holding Tank Size: If Tank is homemade give dimensions: SOILS RATING TYPE OF TANK MANUFACTURER TOTAL ABSORPTION AREA MATERIAL 4. DISTANCES WELL TO: Septic/ Holding Tank Absorption AreaSewer Line Nearest Lot Line Absorption Area to nearest Lot Line S. COMMENTS see ff APPROVED FOR _ 3 BEDROOMS ❑ CONDITIONAL APPROVAL (letter must accompany certificate) ❑ DISAPPROVED GATE 1 1 BY 72010 (Rev. 6/79) AL CHEMICAL & GL..LOGICAL LABORATORIES . Z ALASKA, INC. TELEPHONE 1907)-279-4014 ANCHORAGE INDUSTRIAL CENTER 274.3364 6633 8 Street z' Drinking Water Analysis Report for Total Coliform Bacteria TO BE COMPLETED BY WATER SUPPLIER I' TO BE COMPLETED BY LABORATORY WATER SYSTEM: I I I I I I I r I.D. NO. Water System Nems Phone No. / Mailing Address City `� - State Zip Cods.-.- - SAMPLE DATE: © �� Mo. Day Yost SAMPLE TYPE ❑ Routine ❑ Check Sample (for routine sample with lab ref. no. 1 ❑ Treated Water ❑ Special Purpose ❑ Untreated Water SAMPLE NO. LOCATION z 3 4 51 READ INSTRUCTIONS BEFORE Time Collected Collected I By Analysis shows this Water SAMPLE to be: J] Satisfactory ❑ Unsatisfactory ❑ Sample too long in transit: sample should not be over 48 hours old at examination to indicate reliable results. Please send new sample. Date Received Time Received Analytical Method: ❑ Fermentation Tube Membrane Filter Lab Ref. No. Result' Analyst I I � I I m I I m .No M CObn.s/ loom a Ho M I0u1M pONons 06-1220 (e) BACTERIOLOGICAL WATER ANALYSIS RECORD P". 1978 Date Cgl«t.d Souris a.m. ab R«.IvW Tins R«NvM Pm. Lab. No. Hou" EMS Broth, 24 hours) Blolh e8 holsNl COLLECTING SAMPLE M.W014 Tub. R.00rtl 10ml Tubs PoYttNRoW laml Portions Membrane Febll Dlr«t Count Colltorm/100ml ~fkatloni LTS BOB Mal Membrane FBbr Results cculform/100ml Reporltl SY � Dab ---j T1me a.m. P.M. r.. — ` Y MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH & ENVIRONMENTAL PROTECTION MM CIPALITY OF AN RAGE DEPT. OF VEALT \\1� 825 L Street • Androrys, Alaska 99501 • ENVIRONMENTAL ENVIRONMENTAL ENGINEERING DIVISION JAN 12 79 Telephone 2544720 ❑ One ❑ Four ❑ Other— REQUEST FOR APPROVAL OF INDIVIDUAL WATER AND SEWER ft fFVE DIRECTIONS: Complete all pens on page 1. Intompbb rsqussa will not M proceoad. Rsssa allow ten (10) days for processing. 1. PROP Y OWNER i ❑ Three ❑ Six PHONE MAIL GADLyjESS�Y 7� Z .-teals INDIVIDUAL' P OI SI TY RESIDE_%T (If different from abo, ❑ COMMUNITY PHONE ❑ PUBLIC UTILITY depth (attach log if available.) 127 S. SEWAGE DISPOSAL SYSTEM 6 INDIVIDUAL/ON-SITE" 2. BU s rPHONE If system is over two (2) years old an adequacy test is required ❑ PUBLIC UTILITY by this Department NOTE: THE INSPECTION FEE MUST ACCOMPANY EACH REQUEST BEFORE PROCESSING CAN BE INITIATED. MAILING ADDRESS 3. LE N INSTITU710N� l PHONE MAIt,lug ADDRES 4. Revy���R/ ENT PHONE MAILING ADDRESS S. LEGAL OMRIFTION STREET L CON �t S. TYPEOF RESIDENCE NUM OM P SINGLE FAMILY ❑ One ❑ Four ❑ Other— X Two ❑ Five ❑ MULTIPLE FAMILY ❑ Three ❑ Six 7. WATERS PPLY INDIVIDUAL' ' ATTACH WELL LOG. A well log is required for all wells drilled ❑ COMMUNITY since June 1975. For wells drilled prior to that date, give well ❑ PUBLIC UTILITY depth (attach log if available.) 127 S. SEWAGE DISPOSAL SYSTEM 6 INDIVIDUAL/ON-SITE" "If individual/on-site, give installation date_ If system is over two (2) years old an adequacy test is required ❑ PUBLIC UTILITY by this Department NOTE: THE INSPECTION FEE MUST ACCOMPANY EACH REQUEST BEFORE PROCESSING CAN BE INITIATED. 77-010(3/78) dr /7o S/1't c� s� l�ao rn� c vsPlt ern. THIS SIDE FOR OFFICIAL USE ONLY a INSPECTION APPOINTMENTS DATE RECEIVED TIME TIME TIME DATE DATE DATE INSPECTOR INSPECTOR INSPECTOR DIRECTIONS: 1. TYPE OF RESIDENCE ❑ SINGLE FAMILY ❑ MULTIPLE FAMILY NUMBER OF BEDROOMS ❑ ONE ❑ THREE ❑ FIVE ❑ OTHER ❑ TWO ❑ FOUR ❑ SIX 2. WATER SUPPLY ❑ INDIVIDUAL ❑ COMMUNITY ❑ PUBLICUTILITY Connection Verified PERMITNUMBER DEPTH OF WELL DATE DRILLED , LOG RECEIVED 3. SEWAGE DISPOSAL SYSTEM ❑INDIVIDUAL/ON-SITE ❑PUBLIC UTILITY Connection Verified PERMIT NUMBER DATEINSTALLED INSTALLER ❑Septic Tank or ❑Holding Tank Size: If Tank is homemade give dimensions: SOILS RATING TYPE OF TANK MANUFACTURER TOTAL ABSORPTION AREA MATERIAL 4. DISTANCES WELL T0: Septic/Holding Tank Absorption Area Se~ Line eerest Lot Line Absorption Area to nearest Lot Line 5. COMMENTS ❑ APPROVED FOR BEDROOMS ❑ CONDITIONAL APPROVAL (letter must accompany certificate) ❑ DISAPPROVED DATE BY Title LEGAL DESCRIPTION 72-010 (Rev. 3/78) i A sewer system adequacy test was performed at the three bedroom residence located on the referenced property. The septic tank was pumped on June 2, 1979, and found to have a capacity of 1,000 gallons. The seepage pit was charged with 8S0 gallons of water. Measurements taken on June 3, 1979, reflected a loss of approximately 811 gallons or 270 gallons per bedroom. It can be concluded from the above -survey and test that the sewage system serving the residence on the referenced prop erty is adequate. CF: Security National Bank Municipality of Anchorage, Dept of Health $ Environ Protection Ms. Nancy Frost, Box 14S Juanita Loop Road, Eagle River, Alaska 99577 S7S E-i�1Giiti !NG MVN,.IPALITY C; ANCHORAGE 2a:C1i:;�rC;J.•C;:%I;:r.L't 1•:L'CHADICAL P::GT::::;::": DEPT. C. 1:.'LTICIJTI. rN1_.TF%n" D:. JI_. ..�.I•.::i:h:il' J t..., �,,. CT' 1L JCi:C ..�.C..� EP;/1.^..NTA: IG c• r �'R(li°�1' A. .tL1_ER 6;4-9055 SK", 196X ral;lc River, %la -La 695-2979 99577 JUN5 1979 RECEIVED June 4, 1979 REF: Lot 23, Debra #4 Subdivision Sun Realty AWN: Pete Ostdiek P.O. Box 1201 Eagle River, AK 99577 i A sewer system adequacy test was performed at the three bedroom residence located on the referenced property. The septic tank was pumped on June 2, 1979, and found to have a capacity of 1,000 gallons. The seepage pit was charged with 8S0 gallons of water. Measurements taken on June 3, 1979, reflected a loss of approximately 811 gallons or 270 gallons per bedroom. It can be concluded from the above -survey and test that the sewage system serving the residence on the referenced prop erty is adequate. CF: Security National Bank Municipality of Anchorage, Dept of Health $ Environ Protection Ms. Nancy Frost, Box 14S Juanita Loop Road, Eagle River, Alaska 99577 � w r iLr C�1 %1OL7 S. LEGAL !9C91PTi0N MUNICIPALITY OF ANCHORAGE MUNICIPAUTY CF ANCHORAGE 3 DE►XRTMENT OF HEALTHENVIRONMENTAL PROTECTION DEPT. 0, f.='1P! & E, �y1.. ON,V.ENTAL K0,"CTION STREET ON T' - SL Street -• Anrtdraape, Alaska 99601 ` 26 r] -ter ENVIRONMENTAL ENGINEERING DIVISION JUN 71979 6. TYPE OF RESIDENCE Telephone 264.472D REQUEST FOR APPROVAL OF INDIVIDUAL WATER AND SEWER•PA(.•tLlilW4E D DIRECTIONS: Complete all parts on pope 1. Itwontplote requets will not be processed. Rene allow ten 00) days for processing. 1. PROPS TY OWNER Fe PHONE 95/- ❑ Three ❑ Six e L7- X MAILING ADO E3$ *ATTACH WELL LOG. A well log is required for all wells drilled ❑ COMMUNITY rio since June 1975. For wells drilledr to that date, give well ❑ PUBLIC UTILITY depth (attach log if available.) PHONE r - C.LL rUtie' '_ i '7 7 of If system is over two 121 Years old an adequacy teat is required ystem is over two (2) 2 BUYER by this Department. NOTE:HE INSPECTION FEE MUST ACCOMPANY EACH REQUEST BEFORE PROCESSING CAN BE INITIATED. 71Z 0 MAILING ADDRESS r) O 5 -NJ RYn/ Jett LENDING NJSL ST1T TION U T i o til (f"- 7-9 PHONE MAILING ADDRESS 4. REAL OR/AOF�NT LI Wi1=1 PHONE /ll L 7—V -3z1l MAILIN ODRESS 6. He tin ;✓tom' 77 S. LEGAL !9C91PTi0N 3 STREET ON T' r] -ter 6. TYPE OF RESIDENCE NUMBER I SINGLE FAMILY ❑ One ❑ Fout ❑ Other ❑ Two ❑ Five ❑ MULTIPLE FAMILY ❑ Three ❑ Six 7. WATER SUPPLY �( INDIVIDUAL' *ATTACH WELL LOG. A well log is required for all wells drilled ❑ COMMUNITY rio since June 1975. For wells drilledr to that date, give well ❑ PUBLIC UTILITY depth (attach log if available.) S. SEWAGE DISPOSAL SYSTEM 0 INDIVIDUAL/ON-SITE" I "If individual/on-site,ion date�0: years of If system is over two 121 Years old an adequacy teat is required ystem is over two (2) ❑ PUBLIC UTILITY by this Department. NOTE:HE INSPECTION FEE MUST ACCOMPANY EACH REQUEST BEFORE PROCESSING CAN BE INITIATED. THIS SIDE FOR OFFICIAL USE ONLY INSPECTION APPOINTMENTS DATE RECEIVED' , t TIME TIME TIME DATE DATE DATE INSPECTOR INSPECTOR INSPECTOR DIRECTIONS: " 1. TYPE OF RESIDENCE ❑ SINGLE FAMILY ❑ MULTIPLE FAMILY NUMBER OF BEDROOMS ❑ ONE ❑ THREE ., ❑ . FIVE__.__ ❑ OTHER ❑ TWO ❑ FOUR ❑ SIX 2. WATER SUPPLY ❑ INDIVIDUAL ❑ COMMUNITY ❑ PUBLIC UTILITY Connection Verified PERMIT NUMBER - DEPTH OF WELL DATE DRILLED LOG RECEIVED 3. SEWAGE DISPOSAL SYSTEM ❑INDIVIDUAL/ON -SITE ❑PUBLIC UTILITY Connection Verified PERMIT NUMBER DATEINSTALLED INSTALLER ❑Septic Tank or ❑Holding Tank Size: If Tank is homemade give dimensions: SOILS RATING TYPE OFTANK MANUFACTURER TOTAL ABSORPTION AREA MATERIAL 4. DISTANCES WELL TO: H Septic olding Tank Absorption Arm Line rest of Lim Alnorption Ares to nsrest LM Line - S. COMMENTS 13 BEDROOMS ❑ CONDITIONAL APPROVAL (letter must accompany certificate) ❑ DISAPPROVED DATE BY (Title) LEGAL DESCRIPTION 72010 (Rev. 3/78) uREATER ANCHORAGE AREA BOROUGH Department of Environmental Quality 3330 "C" Street, Anchorage, Alaska 99503 274-4561 Date Received 2/28/75 Time of Inspection Date of Inspection REQUEST FOR APPROVAL OF INDIVIDUAL SEWER & WATER FACILITIES FOR VA 1. Approval requested by: IV. A. Rust Mailing Address: Box 916 Eagle River Phone: 2. Property Owner: Sane Phone: Mailing Address: 3. Legal Description: Lot 23 Deborah Sub Addition 1 4 4. Location: Juanita Loop Road 5. Type of facility to be inspected Single No, of bedrooms 3 6. Well Data: A. Type Filled B. Depth 122' C. Construction Standard 7. Sewage Disposal System: A. Installed 1970 C. Septic Tank: 1. Size D. Bacterial Analysis Satisfacto B. Installer Self 1091 gal 2. Manufacturer D. Seepage Pit: 1. Absorption Area E. Disposal Field: Total length of lines 8. Distances: 540 sq/ft2. Material 34' Logs A. Well to: Septic tank 781 , Absorption area 104' Sewer Lines Nearest lot line 10, plus Other contamination B. Foundation to septic tank 20' plus, Absorption area 201 plus C. Absorption area to nearest lot line 1361 EQ -034 (1/74) Page 1 of two panes Legal Description, Lot [3 Dcborah Sub Addition 8 4 Comments Approved /l. J. Disapproved Date 3/12/75 Approval,Valid for one year from date signed Greater Anchorage Area Borough, Department of Environmental Quality DIAGRAM OF SYSTEM accurate representation of the Subject sewer and water facilities and these facilities ,are operating satisfactorily. SIGNED Date EQ -034 (1/14) _______—T--- GREATER ANCHORAGE AREA BOROUGH Department of Environmental Quality MEMORANDUM October 9, 1973 TO: Rolf Strickland, R.S. Chief Sanitarian FROM: John R. Lee, R.S. Eagle River District Sanitarian SUBJECT: Hyde residence on Juanita Loop Road The Hydes constructed a sewer system recently on lot 30 Deborah Sub., 4th addition, next to the property owned by Amos Burg. This system was inspected by this Dept, and was found to be 100 feet from the Burg's well and at least 97 feet from the Hyde's well. There was a water table problem so the Hydes had to build a drainfield, which they were able to get four feet above the existing water table. Construction was satisfactory, distance requirements were met, and the Hydes instructed to backfill the system. The goats the Hydes use for milk, and are in a fenced area on their property and a large lot that my records indicate to be lot 35 of the Debora fourth addition. There is a pungent odor from the goats that probably becomes quite bad during break up, but nothing that would warrent any legal action by our Dept., at least at this time. sr