Municipality of Anchorage
On -Site Water and Wastewater Section - (907) 343-7904 Page 1 of 3
ON-SITE
WASTEWATER INSPECTION REPORT
Permit Number: OSP171164
PID Number: 015-221-91
Dwelling: ❑ Single Family (SF)
❑ with ADU ❑ Duplex (D) ❑ Two Single Family Project: ❑ New ❑ Upgrade
Name
Jim & Annette Coleman
ABSORPTION FIELD
Deep Trench ❑ Wide Trench ❑ Bed ❑ Mound
Site Address
12131 Upper Heritage Cir. Anchorage, AK
❑ Other
Phone
Number of Bedrooms
Soil Rating iTotal
depth from original grade
770-1536
4
0.8 GPD/SF
8.8 Ft.
LEGAL DESCRIPTION
Depth to pipe invert from original grade
1.8 Ft.
Gravel depth beneath pipe
7.0 Ft.
Subdivision
Block Lot
Cross View Estates
2 3A
Fill added above original grade
2.1 Ft.
Gravel length
54 Ft.
Township Range Section
Gravel width
3.0 ® Ft.
Beds: Number of Lines
Distance between lines
Ft.
SEPARATION DISTANCES
To
Septic
Absorption
Lift Station
Holding
Sewer
Total absorption area
Number of trenches
Dist. between trenches
From
Tank
Field
Tank
Line
756 F6
1
Ft.
Well
>100'
>100'
N/A
N/A
>25'
TANK ❑® Septic ❑ S.T.E.P. ❑ Holding ❑ Other
Manufacturer
Anchorage Tank
Capacity
1,250 Gal.
Surface Water
>100'
>100'
N/A
N/A
Material
Number of compartments
Lot Line
>5'
>10'
N/A
N/A
NA
Steel
2
Foundation
>1 0'
>10'
N/A
N/A
LIFT STATION
Manufacturer
Capacity
Remarks
Gal.
Alarm location
Electrical installed by
PIPE MATERIAL House to tank D3034Tank to D3034
drainfield
Installer
Owner Install
Drainfield D3034 Co/MTD3034
Inspector J. Mlllette
BENCH MARK (Assumed elevation) 100 ft
Inspection15` 5/16/18
5/17/18
Location and description
3 r
2nd
4"'
Bottom of siding @ point B
ON-SITE WATER AND WASTEWATER SECTION APPROVAL
Engineer's Stamp
Sim
OF
Conditional Approval:
Date
° 49th
............................................ ffi
0.MICHAEL E. ANDERSON
Septic System
10(/Qcv()
,No. CE-4381Approved�UUAQDate
�� TF °•.,,,° 1t/7/20
®�
Note: this approval does not include well permit requirements.
•,..••'����'�
a .........N
�r®®gO®®
�f uv VJ/VL/ IO)
CROSS VIEW ESTATES BLOCK 2 LOT 3A
PERMIT # OSP171164 PID # 015-221-91
\ I LOT 2
EXISTING WELL
ALTERNFE SITE n
EDGE A.C. PAVING / / / MT CO2
TH®
—LOT -3A / 54' LONG x 3' WIDE, 7'
/ \ C01 2C0 EFFECTIVE DEPTH
EXISTING ELL SV2 ABSORPTION TRENCI
\\ \' (SERVES -BDR HOUSE) q SVt
BFCO
1,250 GAL SEPTIC TANK/
1 00'WELL RADII
-A\90
71
2�\
LOT 5
1
CN G I N C E AI NG
4-BDRM HOME
0 50 100
FEET
I"=50'
5
� QO
O
OP
A B
FCO
15.0
7.8
SV1
19.5
14.0
SV2
27.2
22.1
2CO
29.8
24.9
C01
21.5
30.1
CO2
76.0
78.3
MT
73.1
76.0
LEGEND
CO - CLEANOUT
2CO - DOUBLE CLEANOUT
FCO - FOUNDATION CLEANOUT
FS - FLOW SPLITTER VALVE
MH - MANHOLE
MT - MONITORING TUBE
SV - SEPTIC VENT
TH - TEST HOLE
CROSS VIEW ESTATES BLOCK 2 LOT 3A
PERMIT # OSP171164
P I D # 015-221-91
94.2 FINISH GRADE
OUB 92.1 ORIGINAL GRADE
AR
DRAINFIELD ROCK
83.3
r® 54'
E- - 76.1
NO GROUNDWATER 6/26/17
PROFILE AS -BUILT
(NO SCALE)
O
0
90.3
RECEIVED 10/31/2019 06:OOPM 9076777766 FORGE
07/13/2019 07:30 907-345-0202 ALPINE DRILLING
MUNICIPALITY OF ANCHORAGE
PAGE 01/03
Development Services Department Phone: 907-343-7904
on -Site Water & Wastewater Section Fax: 907-343-7997
Well Drilling Permit Number: N/A Date of Issue: N/P
Parcel Identification Number: N/,' ----
Lo P'r"X OA Owner Name& Address:
CrgIVIlle iption Block Lot
Cross
le'!C1
SUB. 3A Jim %tte Coleman
6251 Downey Finch Dr.
Anchorage, AK 99516
P=p Installation Date; _08-_27-22.18
Pump Intalm Depth Below Top of Well Casing; 434 feet
Pump Manufacturer's Name: Grundfos
Pump Model: 16530-24
Pump Size: 3 _hp
Pitless Adapter Burial Depth:feet
Pitless Adapter Manufacturer's Name: Maas
_W6'4� &t'
Pitless Adapter Ustaller, Owj'�5ve'
Well Disinfected Upon Completion? J9 yes 0 No
Method of Disinfection., chlorine tablets
Comments*
Please save for COSA.
Pump Installer Name-
Company- Aarow Pump & Well Service, LLC
Mailing Address; P.O. Box 110496
ritw Anchorage State: AK zip-, 99511
Attention., The pump installer shall provide a pump installation log to On-site within 30 days of pump i . astallation.
SGS Ref.#
Printed Date/Time 11/13/2019 15:35
Collected Date/Time 11/04/2019 14:15
Received Date/Time 11/04/2019 14:57
Technical Director Stephen C. Ede
1196612001
Client Name
Forge Engineering Inc.
Project Name/#
CROSSVIEW ESTATES B2 UA -HOUSE
Client Sample ID
CROSSVIEW ESTATES B2 UA -HOUSE
Matrix
Drinking Water
Sample Remarks:
Parameter Results LOQ
Metals by ICP/MS
Arsenic ND 5.00
Waters Department
Total Nitrate/Nitrite-N ND 0.200
Microbiology Laboratory
E. Coli Negative 1
Total Coliform Negative 1
Allowable Prep Analysis
Units Method Container 1D Limits Date Date Init
ug/L
EP200.8
B
(<10)
11/12/19 11/12/19 BMZ
mg/L
SM21 450ONO3-F
C
(<10)
11/05/19 EWW
I00ml- SM219223B A
100ml- SM219223B A
11/04/19 A.L
11/04/19 A.L
f•:
RECEIVED 10/31/2019 06:OOPM 9076777766 FORGE
07/13/2019 07:30 3e7-345-0202 ALPINE DRILLING
PAGE 02/03
i 0 _1� =hone: �907-3=3-79M
Development Services Department Fax: 907-343-7997
On -Site Water & Wastewater Section 0*)
Pump Installation Log 3 _7 06
Well Drilling Permit Number: 060028 Date of Issue:
Parcel Identification Number: 01 x_221.49
e
Block. Lot proXerty owner Name & Address:
-LaJim Annette Coleman
ME View Estates Description 2 3A 6251 Downey Finch Dr,
Anchorage, AK 99516
pump installation Dater 9 -io _q8
- 423
pump intake Depth Below Top of Well Casing'. - feet
Pump Alarufacturer's Name: Go"d'
pump Zvfodel; 5H 3 10
Pump gize. 1 ho
Fitless Adapter Burial Depth: n/a feet
Mess Adapter Manufacturer's Name: lila
Pitless Adapter Installer* n/a
Well Disinfected Upon Completion? S yes 0 Na
�Vethod of Disinfection: chlorine tablets
Comments,
PLEASE SAVE FOR COSA.
Pump Installer Name' David Harper
C..,any, Aarow Pump & Well SVS, LLC
Mailing Address. Po Box 110496
City-' Anchorage state: Alaska Zip; 99511
Attention' The pump installer shall provide a pump installatioll log to 0,a -site withi-a 30 days o£pump iiistallation.
COPY
SGS Ref.#
1196613001
Client Name
Forge Engineering Inc.
Project Name/9
Crossview Estates B2 L3A
Client Sample ID
Landscape Well
Matrix
Drinking Water
Printed Date/Time
11/13/2019 15:35
Collected Date/Time
11/04/2019 14:30
Received Date/Time
11/04/2019 14:57
Technical Director
Stephen C. Ede
Sample Remarks:
Allowable Prep Analysis
Parameter Results LOQ Units Method Container ID Limits Date Date Init
Metals by ICP/MS
Arsenic ND 5.00
Waters Department
Total Nitrate/Nitrite-N ND 0.200
Microbiology Laboratory
E. Coli Negative 1
Total Coliform Negative 1
ug/L
EP200.8
B
(<10)
11/12/19 11/12/19 BMZ
mg/L
SM21 450ONO3-F
C
(<10)
11/05/19 EWW
100mL SM219223B A
100mL SM219223B A
11/04/19 A.L
11/04/19 A.L
2
RECEIVED 10/31/2019 MOM 9076777766 FORGE
07/13/2019 07:30 907-345-0202 ALPINE DRILLING
MUNICIPALITY F ANCHORAGE
DEVELOPMENT SERVICES DEPARTMENT 907-343-7904
On -Site Water and Wastewater Section Fax: 343-7997
www,munI.orzwv"4 e
Well Decommissionin
............. %supp.
Legal Address:
Subdivision —Block _-P— LotY
T R_ Section Lot
On-slte Water & Wntewoter Section certified contractor performing the well decommissioning:
Name: Signature:
David Harper
Company:
Alpine Drilling & rEnterprises,_
Well decommissiorilhg data Method ofdecQrnmisslonlng: AMC 15,55.0601-1 ❑b,
C.
PAGE 03/03
Location: Use the space beton to provide a drawing of the property showing the following itemv: tv
North arrow AN
DG�wmmlssioned well location
Location of other water wells on the property
Two separate swing -tie distances for each well shown on the drawing
Note: The swing-fle distance.9 shall be measured from either permanent structures or the property comms.
VO. n R"+—v k
�
G.Wevelop"'ant
•........ #
'y e10z/or/o1 ••
4C,�•ipa�L609-SI
+pis, sem®
at .........( ..
r+16b
® S y e
®®®® >b JO ®p®®
0d0� NdWjjnN
i
•j•S L60'18
Z >10018 'V5£ 101
NOISIAI(ions S31ViS3 M31A SSO(xJO
Z4 -L I OZ 'ON lvld
Ml
ddZV£3A0
ZO-131
31x0 Si HI 13S S63NHo0 ON :31ON
'ON ear
aD
VASVIV '101HIS10 ONIOM0038 30V80HONV
6tOZ/0£/Ot
L£LZMS
'S3Nil 3ON33 80 A21VONnos ONIHSII8VIS3
210-1 80 NOU:Dn8ISNO0 2103 03Sn 38 N0383H
Diva
0160
VIVO ANv OlnOHS S30Nv1Svm:)8io ON 830Nn
ggpg-gyZ 3NOHd
'lvld NOISIru08nS 03080038 31-i1 NO 6V3ddV
L0666 V>ISVly '3!)V80HONV
ION 00 HOIHM SNOIIDIZIIS38 80 S1NVN3AOO
g DIMS"ON ON11M00 •3 DOW
AN
SIN3n3Sv3 v 30 30N31SIX3 31-11 3NIV483130
S.1.8 'IolvlSVO v 3j3r
01 83NMO 31-11 30 A111181SNOdS38 31-11 S1 11
1OII 'ONIA3A8nS
*031VOlONI SV id30X3 ISIX3 SIN3WHOVO8:)N3
ONYI 10.MISVO
ON 1VH1 ONV 3A08V 03101d30 AI83dO6d
31-11 03A3A2inS 3AVH I IVHI A311830 A83213H I I
11 0 no— G; w
0d0� NdWjjnN
i
•j•S L60'18
Z >10018 'V5£ 101
NOISIAI(ions S31ViS3 M31A SSO(xJO
Z4 -L I OZ 'ON lvld
Ml
r,„,,' "”' MUNICIPALITY OF ANCHORAGE ocnr
On-Site Water & Wastewater Program t° 5,. ,
PO Box 196650 4700 Elmore Road �
Anchorage,Alaska 99519-6650 Phone:(907)343-7904 Fax:(907)343-7997 _
http://www.muni.org/onsite '
-- t):Tai tiut.ni
On-Site Wastewater Disposal System Permit
Permit Number: OSP171164 Effective Date: 7/6/2017
Work Type: Septic Initial Expiration Date: 7/6/2018
Tax Code Number: 01522191000
Site Legal Address: CROSS VIEW ESTATES BLK 2 LT 3A G:2737
Site Mailing Address:
Owner: COLEMAN JIM & ANNETTE Lot Size in Sq Ft: 87091
Design Engineer: ANDERSON ENGINEERING Total Bedrooms: 4
This permit is for the construction of:
0 Disposal Field 0 Septic Tank ❑ Holding Tank ❑ Privy ❑ Private Well ❑ Water Storage
All construction shall be in accordance with:
1. The attached approved design.
2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska
Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80)
3. The wastewater code requires inspections during the installation. The engineer shall notify the Development
Services Department per AMC 15.65. Provide notification by calling (907) 343-7904 (24/7).
4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather
shall be either:
a. Opened and Closed on the same day. or
b. Covered. sealed. and heated to prevent freezing
Special Provisions:
1. To close out this permit, please submit the following:
a) Inspection report and record drawings.
b) Pump install log and water sample results for the well serving the residence.
0_ c) Decommissioning logs for the two additional exploratory wells that were drilled on this lot.
1
Received By: .,2C4(X g fzt� ,�1��//zee 1 Date: /
Issued By: / t,e.� ,,,s_ zz,". Date: 77241 7
MUNICIPALITY OF AI C: RAGE
r■
Community Development Department ►jt J viz 7_ hone: 907-343-7904
Development Services Division a JUN L 7 2 Fax: 907-343-7997
On-Site Water & Wastewater Program lti
6 /
ON-SITE SEWER/WELL PERMS \Af?RLA N
Lb
Parcel I.D. 015-221;66 9
Property owner(s) Jim and Annette Coleman Day phone 770-1536
Mailing address 10380 Nigh Road Anchorage, AK 99515
Site address NHN Upper Heritage Circle Anchorage, AK 99516
Legal description (Sub'd., Block & Lot) Cross View Estates, Block 2, Lot 3A
Legal description (Township, Range & Section)
Lot Size 87,091 Sq. Ft. Number of Bedrooms Four (4)
APPLICATION IS FOR: APPLICATION IS AN: TYPE OF DWELLING:
(®all that apply)
Absorption Field Q Initial ❑ Single Family (SF) E
(w/wo ADU)
Septic Tank Q Upgrade ❑ Duplex (D) ❑
Holding Tank ❑ Renewal ❑
Multiple Dwellings ❑
Privy ❑ (SF and/or D)
Private Well
Water Storage El
THIS APPLICATION INCLUDES A VARIANCE /WAIVER REQUEST FOR:
Distance:
I certify that the above information is correct. I further certify that this is in accordance with
applicable Municipal Codes.
Gltt--,Il-�r
(Signature of property owner or authorized agent)
Permit/Rush Fees: ' L4q -r Waiver Fees:
Date of Payment: to 130 !I i Date of Payment:
Receipt Number: O8 gas G Receipt Number:
Permit No. 051?11 �Ilp� Waiver No.
Permit App_9-1-12.doc
ANDERSON ENGINEERING
P.O. BOX 240773
ANCHORAGE, AK 99524
522-7773 677-7766 (FAX)
June 27, 2017
Municipality of Anchorage
Development Services Department
On-Site Water and Wastewater Program
4700 South Bragaw Street
Anchorage, AK 99519-6650
Subject: Lot 3A, Block 2, Cross View Estates Subdivision
Septic System Design and Permit Application
Impacts to Adjacent Properties
Dear Onsite Services Engineer:
The owner of Lot 3A, Block 2, Cross View Estates Subdivision intends to construct a
new four-bedroom home on the lot. We are therefore requesting a permit be issued for
the construction of a new septic system to accommodate the home. Two wells are in
place on the lot which were used during the aquifer test on the original subdivision.
One of the wells will be abandoned in accordance with ADEC and Municipal Code. The
attached Site Plan and backup documentation identify the location and configuration of
the existing wells and proposed septic system along with the alternate site. Also
identified on the plans are the existing wells in the area and septic systems on
surrounding lots. No conflicts exist between the proposed septic system and well or
septic systems and wells on adjacent lots. Drainage arrows are shown on the site plan
showing the grade and direction of flow on the lot. The drainage pattern will not be
changed as a result of this project.
The test hole placed on the lot in the area of the absorption trench and alternate site
indicate silty sand with gravel (SM/GM). The percolation rate of the soil was
determined to be 14.1 minutes per inch. No groundwater was found during the
placement of the test hole and none was noted during the monitoring period. An
application rate of .8 gallons per day per square foot was used in the design of the
absorption system. We are proposing to place a new 1 ,250-gallon septic tank and a 54'
long by 3' wide by 7' effective depth absorption trench to treat and dispose of the
effluent generated in the house. The elevation of the distribution line in the absorption
trench will be 2' below the surface and the total depth will be 9'. A minimum of 3' of fill
or 2" of insulation and 2' of fill will be placed over the absorption trench and 4' over the
septic tank.
Lot 3A, Block 2, Cross View Estates Subdivision
June 27, 2017
Page Two
The ground surface on the lot in the area of the septic system slopes to the northwest
at a grade approaching 20% with some cross sloping from the east. The new trench
will be constructed parallel with the contours of the slope as much as possible in
conformance with Municipal requirements. The new septic system will be constructed a
minimum of 100' from all wells and any surface water and 10' the proposed and existing
water services in the area.
If the system is constructed in accordance with our design the following statements
apply:
1. The system, if constructed as designed, will have no adverse impact on the wells
in the area or those to be constructed in the future.
2. The system, if constructed as designed, will have no adverse impact on existing
septic systems in the area or those to be constructed in the future.
3. The system, if constructed as designed, will have no adverse impact on reserve
space, either surface or subsurface, on any lots located in the area.
4. The system, if constructed as designed, will have no adverse impact on drainage
patterns in the area. The current drainage pattern will be maintained.
Sincerely, OF .4 81 ikt
#.% ; .'7
Benjamin Schiller, P.E. 9.< ..... ......"•„.y
Attachments �0�y%
t• iW.R" ft•�' }j�F „ u.
IS f r 2 6!
°7 414?•••`vti �
11%CI,Ts,r+,`. ''.
/
`�
1
\ •\ Diana M+ I t
f
t
\ ,
t
LOT 9 1 't / LOT 2
It
� i f
LOT 8
1 I// I
S)11 VACANT i ��,_ t _►
I
' \: :CY/ 4 'I'd
1_______L: , WI 4.,
i ��' / iirm.: r.d)
\ I
d
'41/
ii=1:/// 1
I - '
1 /
/
':/
/
LOT 5 .•\ %
\ a
/,
Z
Cl /�
Nuff � '
iosisrmilitii
• � CROSS VIEW ESTATES
• �`� 49th :E. , LOT 3A, BLOCK 2
1 MICHAEL E. ANDERSON•; i AREA M A P
t/ •• Na. CE-4381 r
V. '.••4-t$ i?.••'
...4).
SCALE 1' = 100'
7x
CROSS VIEW ESTATES
LOT 3A, BLOCK 2 ,/* LOT 2
87.091 S.F. 1/ / // \ 52.2110
204,
'As
�r ... / N''''..°.7.9
�R d.' MT
Alternate
/� ��`03 '� Site TH1
`�Jr w o„ ® 54' Long x 3' Wide r 760 J
c, x 7' Effective Depth r I
2C0
��' Absorption Trench r
I/'/ ;
*N 1.250 Gallon / '
1 Al
= �' Septic Tank / Zi/
1 � FCO
111 / / /
1 ,//
/
i
\ t __- ' /i /
/ /
1 /
1 /
1 % /
1 / /
1 /
1 /
t /
.it °-1 \
LOT 5
„1
A -
r11 1,.* � , / /
,y '� /
LEGEND
1 a�. MT — Monitor Tube
s� ��•/..6'1/4-
� 44 /' MH — Mon Hok
1 ..� . 1 FCO — Foundation Clean Out
�� $. r/ TH — Test Hole
11 �' • CO — Clean Out
.' / FSV — Flow Splitter Valve
1 -'
2C0 — Double Clean Out
-i'
1 '
NOTE: 11, ,. I +Willi•iiiII
No Areas of Excessive Slope or Surface $ 11 • +�4, 4a,
Water are Within 100• of AnyPart of the G
New Septic System. No Wells or Wastewater i �1 / �.44;1\‘>.'rr� .•' '• ,�
Systems on Adjacent Lots Conflict with the 1 —J;'
Proposed Septic System. 1---'� /
f s • 49th * •
10
I117.44-tie-0-4-7..Z (-1-"'1' :�
SITE PIAN _ , =HICHAELE. ANDERSDN ,,�,
SCALE 1' = 60' •:� FE;;*N.\-44
LOT 3A, BLOCK 2, CROSS VIEW ESTATES
DESIGN FACTORS: SYSTEM REQUIREMENTS:
Four Bedroom Home Deep Trench System
Perc. Rate: 6-15 Min./Inch 1,250 Gallon Septic Tank
Application Rate: .8 GPD/SF 7' Drainfield Rock
4 Bedrooms X 150 GPD/.8 GPD/SF (Application Rate) = 750 SF Absorption Area
750 SF/14 SF/LF = 53.57 LF Trench Length
THEREFORE: Construct a 54' Long x 3' Wide x 7' Effective Depth Absorption Trench at the
Location Shown. Flow Line Elevation in Trench to be 2' Below Original Ground Surface. Total Depth
to be 9' Below Existing Ground. Provide 4' Cover Over Septic Tank and 3' Cover Over Absorption
Trench. Maintain 100' Separation from all Wel!sin the Area.
Natural
Backfill
1'6"
Geotextile
Fabric
6" O 4" Perforated
PVC (Holes Down)
7'0"
Drainfield Rock
3'
I I
TYPICAL DEEP TRENCH SECTION �/
(NO SCALE) P( •44
=� .
NOTE: Grade Area Over Trench to Drain Away. Z2v. *
Minimum 6' Separation From Bedrock. 49th s
Minimum 4' Separation From Groundwater. * c �Uf
Minimum 100' Separation From All Wells in the Area. � : •MICHAEL E.ANOEHSON ••LLI
•
Minimum 100' Separation From Surface Water or Streams. 11061-pNo. CE-4381
MUNICIPALITY OF ANCHORAGE _ •ymi1llN
DEVELOPMENT SERVICES DEPARTMENT � a
#� P + .
4700 BRAGAW STREET ANCHORAGE, AK 99519-6650 i•�' % .•
..4: ;
MUNICIPALITY OF ANCHORAGE
Development Services Department
On -Site Water d Wastewater Program
4700 South Bragaw Street
P.O. Box 196650, Anchorage, AK 99519-6650
(907) 343-7904
ON-SITE WATER SUPPLY PERMIT
Initial
Permit Number: SWO60028
Legal Description: HERITAGE HILLS #1 TFt'G` L07'_r
Design Engineer: 0000 None Required
Owner Name: CFM HILLSIDE, LLC
Owner Address: 10380 NIGH ROAD
ANCHORAGE. AK 99515 -
Date Issued: Mar 07, 2006
Expiration Date: Mar 07, 2007
Parcel ID: 015-221-40
Site Address: 012241 BAINBRIDGE RD
Lot Size: 2431955 SO. FT.
Total Bedrooms: 6 Permit Bedrooms: 6
This permit is for the construction of:
❑ Disposal Field ❑ Septic Tank ❑ Holding Tank ❑ Privy Z Private Well ❑ Water Storage
All construction must be in accordance with:
1. The attached approved design.
2. All requirements specified in Anchorage Municipal Code Chapters 15.55 and 15.65 and the State of Alaska
Wastewater Disposal Regulations (18AAC72 ) and Drinking Water Regulations ( 18AAC80 ).
3, The engineer must notify DSD at least 2 hours prior to each Inspection. Provide notification by calling
(907) 343-7904 (24 hours). ( Not required for a Water Supply Permit only).
4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather
must be either: A. Open and closed on the same day.
B. Covered, sealed, and heated to prevent freezing.
5. The following special provisions.
-WHEN THE WELL HAS BEEN COMPLETED AND SATISFACTORY WATER PRODUCTION HAS BEEN
DETERMINED, THE WELL DRILLER SHALL PLACE AN APPROVED SANITARY SEAL ON THE WELL HEAD AND
NO PITLESS ADAPTER OR PUMP SHALL BE INSTALLED UNTIL AN APPROVED WASTEWATER DISPOSAL
SYSTEM HAS BEEN CONSTRUCTED.
i' -THIS PERMIT IS FOR THE PROPOSED HERITAGE HILLS LOT 3 1
Received By:
Date: cpco
Issued By (" — Date: 2 2 0
Municipality of Anchorage
Development Services Department
Building Safety Division
On -Site Water and Wastewater Program
4700 Bragaw St.
P.O. Box 196650 Anchorage, AK 99519-6650
www.ci.anchorage.ak.us
(907)343-7904
ON-SITE SEWER/WELL PERMIT APPLICATION
FOR A SINGLE FAMILY DWELLING
Parcel I.D. _Q jE2-d_aj— 40 — [0o Permit Number SW
Property owner(s) Day phone _,344 —R'>?2
Mailing
Site address
Legal description (Lot, Block & Sub'd.)
Legal description (Section, Township & Range)
Lot Size a) S -1d Acre q.Ft.
THIS APPLICATION IS FOR:
Code gg51 'r;'
Code E'er_
c fl AA : 4. ^,A '-1
Number of Bedrooms to
Sewer Only ❑ Well Only
Sewer and Well ❑ Water Storage ❑
Sewer Upgrade ❑
THIS PROPERTY CONTAINS:
Hot Tub ❑ Jacuzzi ❑
Swimming Pool ❑ Water Softening Unit ❑
Therapy Pool ❑
I certify that the above information is correct. I further Certify that this application is being made for a
Single I,gmily Dwelling and is in accordance with applicable Municipal Codes.
(Signature of property owner or authorized agent)
Permit/Rush Fees: % 15'o Waiver Fees:
Date of Payment: !O A (/t) S Date of Payment:
Receipt Number: -75/2q Receipt Number.
(Rev. 09/04)
J. A. MUNTER CONSULTING, INC.
October 11, 2005
Mr. Dan Roth
Municipality of Anchorage
Development Services Department
Building Safety Division
On -Site Water and Wastewater Program
PO Box 196650
Anchorage, AK 99519-6650
Re: Aquifer Test Plan update, Heritage Hills Subdivision, Anchorage, Alaska
Dear Mr. Roth: C" Ids 3q a .3
I am providing you this plan on behalf of the owners o the proposed Heritage Hills Subdivision
to accompany well permit applications for the drilling,'wo additional test wells at Heritage Hills
Subdivision near the comer of Birch and Huffman Roads in Anchorage. Please see my letter to
you dated September 15 and the map provided to you on this project.
Subsequent to the testing and approval phase for this project we anticipate converting the wells
to private domestic wells and they will be located and constructed to meet municipal standards
for residential wells.
At this time we are only requesting permits for drilling wells. Subsequent hydrologic test plans
need to await the results of the drilling and we will be inform you as the program develops.
Should you have any questions about this plan or the attached well permit applications, please
call me at 345-0165 or on my cell phone at 727-6310.
Sincerely,
J. Munter Consulting, Inc.
lames A. Munter, CGWP, CPG
Principal Hydrogeologist
5701 PENNY CIRCLE, ANCHORAGE, AK, 99516
i amunter(a-`arct ic.n et
PHONE(907)345-0165; FAx (907) 348-8592
c
N Q
Oo
rn l �? \
(Do: v \
Ji N `
v
IT I tN) to
Ln
N 1
\>oJ�
0') Ln N
O Cli\ �C I
d'
y
w
Q
N '
00 (jo I
d- Q
cr w N
to
r0 t I
�r I
ALPINE DRILLING & ENTERPRISES
Permit Number: #SW050352 Date of Issue: 9-19-05 Parcel Identification Number: 015-221-40
Date Started: 9-25-05 Date Completed: 10-2-05 Is well located at approved permit location? ® Yes ❑ No
Legal Description: Heritage Hills L -
Property Owner Name & Address: CFM Hillside, LLC and W2ion L o� Ll
10380 Nigh Road `���� �I W 19>
Anchorage, Alaska 99515 l
Borehole Data:
Depth (ft)
Method of Drilling ® air rotary ❑ cable tool
Soil Type, Thickness & Water Strata
From
To
Casing type: steel
silt
0
2
Wall Thickness: .250 inches
gravelly silty sand
2
16
Diameter: 6 inches Depth: 325 feet
silty gravel
16
24
Liner Type:
Diameter: inches Depth: feet
gravelly silt
24
27
Casing stickup above ground: 2 feet
silty sand
27
56
Static water level (from ground level): feet
gravel
56
59
Pumping level: feet after
silty gravel
59
63
hours pumping gpm
silty sand
63
91
Recovery Rate: gpm
gravelly silt
91
105
Method of Testing:
Well Intake Opening Type:
silty gravel 105 179
gravelly silt
179
235
❑ Open End ❑ Open Hole
❑ Screened Start feet Stopped feet
silt
235
243
❑ Perforations Start feet Stopped feet
gravelly silt
243
262
Grout Type: bentonite granules Volume: 1 biz
silty gravel wet
262
270
Depth: Start 0 feet Stopped ? feet
gravelly silt
270
I%g
Pump: Intake Depth feet
bedrock
319
340
Pump size hp Brand Name
Well Disinfected Upon Completion? ® Yes ❑ No
Method of Disinfection:
Comments: well was not completed due to loss of tools
in bedrock. Enough flow could likely be obtained for a
household at the 262 level by perforating. If not used, will
be decommissioned after a new well is installed.
Well Driller: Alpine Drilling & Enterprises
PO Box 110496
Anchorage 99511 Zip
Attention: The well driller shall provide a well log to the property owner within 30 days of completion and the property
-1 --.--- -.. i7-- ----1, -A..n1-.. .1._11 .... ---•-1- - •---111-- 1.- af_. T----1_._.._.._• 0-.—.7_-..71..- 1.• -n .1--.. .r. -. ... ..1..a0-...
MUNICIPALITY OF ANCHORAGE
Development Services Department
On -Site Water d Wastewater Program
4700 South Bragaw Street
P.O. Box 196650, Anchorage, AK 99519-6650
(907) 343-7904
ON-SITE WATER SUPPLY PERMIT
Initial
Permit Number: SWO50352
Legal Description: HERITAGE HILLS #1 Tiv,=0r, Gor /
Design Engineer: 0000 None Required
Owner Name: CFM HILLSIDE, LLC
Owner Address: 10380 NIGH ROAD
ANCHORAGE. AK 99515 -
Date Issued: Mar 07, 2006
Expiration Date: Mar 07, 2007
Parcel ID: 015-221-40
Site Address: 012241 BAINBRIDGE RD
Lot Size: 2431955 SO. FT.
Total Bedrooms: 6 Permit Bedrooms: 6
This permit is for the construction of:
p Disposal Field ❑ Septic Tank ❑ Holding Tank ❑ Privy Private Well ❑ Water Storage
All construction must be in accordance with:
1. The attached approved design.
2. All requirements specified in Anchorage Municipal Code Chapters 15.55 and 15.65 and the State of Alaska
Wastewater Disposal Regulations (18AAC72 ) and Drinking Water Regulations ( 18AAC80 ).
3. The engineer must notify DSD at least 2 hours prior to each inspection. Provide notification by calling
(907) 343-7904 ( 24 hours ). ( Not required for a Water Supply Permit only ).
4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather
must be either: A. Open and closed on the same day.
B. Covered, sealed, and heated to prevent freezing.
5. The following special provisions.
-WHEN THE WELL HAS BEEN COMPLETED AND SATISFACTORY WATER PRODUCTION HAS BEEN
DETERMINED, THE WELL DRILLER SHALL PLACE AN APPROVED SANITARY SEAL ON THE WELL HEAD AND
NO PITLESS ADAPTER OR PUMP SHALL BE INSTALLED UNTIL AN APPROVED WASTEWATER DISPOSAL
SYSTEM HAS BEEN CONSTRUCTED.
4 -THIS PERMIT IS FOR THE PROPOSED HERITAGE HILLS #1 LOT 4 t
Received By:
Date:
Issued By: Date: 3 7 OG
Municipality of Anchorage
Deveiopment Services Department oil'"`'�
Building Safety Division
_
On -Site Water and Wastewater Program
4700 Bragaw St
P.O. Box 196650 Anchorage, AK 99519.6650
www.ci.anchorage.ak.us
(907) 343.7904
ON-SITE SEWERIWELL PERMIT APPLICATION
FOR A SINGLE FAMILY DWELLING
Parcel 1. D.QIr-3-ca.t- 4,p-rm Permit Number SW
Propertyowners) CFM . tom(` . Day phone 344 - 92VA
Mailing
Site adc
Legal di
Legal description (Section, Township & Range) SE. A. st=C. Aa -r fa ,A�23� S . M .
Lot Size—A.?-5 otwrt Acres/Sq.Ft. Number of Bedrooms (O
THIS APPLICATION IS FOR:
Sewer Only ❑ Well Only 0
Sewer and Well ❑ Water Storage ❑
Sewer Upgrade ❑
THIS PROPERTY CONTAINS:
Hot Tub ❑ Jacuzzi ❑
Swimming Pool ❑ Water Softening Unit ❑
Therapy Pool ❑
I certify that the above information is correct. I further Certify that this application is being made for a
Single Family Dwelling and is in accordance with applicable Municipal Codes.
(Signature of property owner or authorized agent)
Permit(Rush Fees: �'t S. 00 }.115=35oPWaiver Fees:
Date of Payment:
Date of Payment:
Receipt Number. Receipt Number:
(Rev. 09/04)
J. A. MUNTF.R CONSULTING, INC.
September 15, 2005
Mr. Dan Roth
Municipality of Anchorage
Development Services Department
Building Safety Division
On -Site Water and Wastewater Program
PO Box 196650
Anchorage, AK 99519-6650
Re: Aquifer Test Plan, Heritage Hills Subdivision, Anchorage, Alaska
Dear Mr. Roth:
I am providing you this plan on behalf of the owners of the proposed Heritage lulls Subdivision
to accompany well permit applications for the drilling and testing of four test wells at Heritage
Hills Subdivision near the comer of Birch and Huffman Roads in Anchorage. Subsequent to the
testing and approval phase for this project we anticipate converting the wells to private domestic
wells and they will be located and constructed to meet municipal standards for residential wells.
Our plan is to drill one test well on lot 35 to determine whether a sand and gravel aquifer is
present in that area. Existing information indicates that the depth to bedrock in that area is more
than 150 ft. Assuming that a sand and gravel aquifer is present, we propose to drill three
additional test wells on lots 6, 55, and 56 in order to fully test the aquifer at heritage Hills
Subdivision using the Municipality of Anchorage's "Aquifer Test Procedures" handout that you
provide to us at our meeting yesterday. If a sand and gravel aquifer is not present at the site of
the first well drilled, we will subsequently provide you with a plan and additional well permit
applications for testing and evaluating the bedrock aquifer at the site.
We have carefully selected the site of the proposed three -well test to be centrally located in the
largest portion of the development. The locations of the proposed test wells are shown on the
attached map of the subdivision.
Should you have any questions about this plan or the attached well permit applications, please
call me at 345-0165 or on my cell phone at 727-6310.
Sincerely,
J. A. Munter Consulting, Inc.
James A. Munter, CGWP, CPG
Principal Hydrogeologist
5701 PENNY CIRCLE, ANCHORAGE, AK, 99516
iamunternarctic.net
PHHoNE(907)345-0165; FAx(907)348-8592
i
co
to
In
I �
I
0tn
N
00to
C N
N I�
U) L
.47
1 �
v
\
C
Q
N
\C7
V
lD
10
\O
Ld
�
N
N
1
0tn
N
00to
C N
N I�
U) L
.47
1 �