Loading...
HomeMy WebLinkAboutNETTLETON ACRES #1 LT 1AOnsite File Nettleton Acres #1 Lot 1A PID# 015-062-69 Formerly Nettleton Acres #1 Lot 1 Municipality of Anchorage Community Development Department Page 1 of 3 Onsite Water and Wastewater Program 4700 Elmore St. • P.O. Box 196650 Anchorage, AK 99519-6650 • http://www.muni.org/onsite • (907) 343-7904 ON-SITE WASTEWATER INSPECTION REPORT Permit Number: OSP151168 PID Number: 015-062-62 ❑ New 21 Upgrade Name: Kelley Brockway ABSORPTION FIELD Q Deep Trench ❑✓ Shallow Trench ❑Bed ❑Mound Address 9410 Nettleton Drive Anchorage, AK 99507 ❑ Other Phone Number of Bedrooms Soil Rating - Total depth from original grade 6 2 GPDlSF 5.3 Ft. LEGAL DESCRIPTION - Depth to pipe invert from original grade 2.3 Ft. Gravel depth beneath pipe 3Ft. Subdivision Block Lot - Nettleton Acres #1 1 Fill added above original grade - - 1-2 Ft, Gravel length 53 Ft. Township Range Section Gravel width 5Ft. Beds: Number of Lines Distance between lines Ft. SEPARATION DISTANCES To Septic Absorption Holding Severer Total absorption area Number of trenches Dist. between trenches From Tank Field Lift Station Tank Line -913 Ft' TwD >10 F1. Well >100' >100' >100' >75' >25' TANK ❑ Septic ❑ S.T.E.P. ❑ Holding El Other Manufacturer Existing Capacity I Gal. Surface Water >100' >100' >100' >100' Material Steel Number of compartments Two Lot Line >5' >10' N/A N/A NA Foundation >5' >10' N/A N/A LIFT STATION Manufacturer Capacity Curtain Drain None Noted Gal. RemarksAbsorption Trench Only Constructed Under Pump on level at in. Pump off level at in. High water alarm at in. This Permit. Flow Diverter Valve Placed and Existing Trench Connected for Future Use. Pump make and model Electrical Inspections performed by Installer PIPE MATERIAL Housetotank D3034 Tank to D3034 drainfeld PCN Construction, Inc. Drainfield F810 CO/MT D3034 Inspector M. Anderson BENCH MARK (Assumed elevation) 100.Oft Inspdates: 1" 6/17/15 6/18/15 Location and description 2"tl P 6/30/15 a"' Garage Slab. COMMUNITY DEVELOPMENT DEPARTMENT APPROVAL 11�+ O '' A Conditional Approval: Date �J� •'•, so MICHAEL E. ANDERSON ,pROfESSIONp� Approved /i(/. Date'%`% tie, �fO ��� Inspection Report _1-1-12.d • i; A q'9��� N N K 0OL %N:�m :Oi N N O co D o' 0 N C O [1N / (D A < Y o / OBD OD •OW) al Co !A *Ail CA tico rl o < m I m ^ /' o 3 p O O 3 F O O _ Z Co 0 m O a UlN m 3ri _ 00 1 Z �m s z co r 0 < 0, X D N m m T� W M N DOo ,�/i /\ \�� . W OND m SON DOD J Z 6m\ m \ s ._.m In r 2 I o m I 0�d 0 0 . m m.. H s� Poll,11I\\\F D —�LZ'8ti l 3„ l L,Z0.00 S 3AINO N013-1113N Z m — O m ..osa:o...�wxeau O_ O W O O N 6 N Municipality of Anchorage Page 3 of 3 DEVEOPMENT SERVICES DEPARTMENT 4700 Elmore Road Anchorage, AK. 99519-6655 - 343-7904 On -Site Wastewater Disposal System or Well Inspection Report Permit Number: OSP151168 PID No. 015-062-62 EXISTING Ui F- 89.4 FinWhed erede 88.0 20 85.7 11 Draintield Rock II I —� 85.7 82.7 1 11 82.7 75.0 53' (Trench Length) Groundwater @ 77.0' 6-8-92 NOTE: Absorption Trench Only Constructed Under This Permit. PROFILE AS -BUILT No Scale -'gni —!b; MUNICIPALITY OF ANCHORAGE DEVELOPMENT SERVICES DEPARTMENT 4700 BRAGAW STREET ANCHORAGE, AK 99519-6650 DEPTH (feet) 1- 2- 3 - 4 - 5 - 6 - 7 - 8- 9- 10- 11- 14 15 16 17 18 19 SOILS LOG - PERCOLATION TEST LEGAL DESCRIPTION: NETTLETON ACRES No. I, LOT I PERFORMED FOR: KELLEY BROCKWAY DATE: 6/17/15 PROJECT No.: PARCEL ID#: TECHNICIAN: MEA TEST HOLE A OB/OG SILTY SAND WITH GRAVEL SM/GM BOH @ 16' SLOPE WAS GROUND WATER ENCOUNTERED? No IF YES @ WH DEPTH OF WATER AFTER MON DATE OF MO 49th.`: MICHAEL E. ANDERSON NO. CE -4381 ••.,_ 6-23-15 ,lC SI I L PLAN SEE SITE PLAN B i AT DEPTH? TORINO NITORING: P E DATE READING GROSS TIME (MINUTES) NET TIME (MINUTES) DEPTH TO WATER (INCHES) NET DROP (INCHES) TEST HOLE PRESOAKED PRIOR TO TESTING- ESTING:6/17 6/17 1 1:15 2 1:45 30 3.75° 2.25„ 3 1:46 1.75^ 4 2:16 30 4.00^ 2.251, 5 2:17 Lso^ 6 2:47 30 3.75^ 2.25" PERCOLATION RATE: 13.3 (MIN/INCH) PERC. HOLE DIA. 6„ (INCHES) TEST RUN BETWEEN: 4 FT. and 5 FT. COMMENTS: TEST HOLE PRE SOAKED PRIOR TO TEST. PERCOLATION TEST ONLY. TEST PERFORMED BY ANDERSON ENGINEERING. 1, MICHAEL E. ANDERSON CERTIFY THAT THIS WAS PERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPLE GUIDELINES IN EFFECT ON THIS DATE: 6/60/15 On -Site Wastewater Disposal System Permit MUNICIPALITY OF ANCHORAGE Development Services Department On -Site Water & Wastewater Program 4700 Elmore Road, PO Box 196650 Anchorage, AK 99519-6650 Telephone: (907) 343-7904 Permit Number: OSP151168 Tax Code Number: 01506262000 Work Type: Septic Upgrade Permit Effective Dates: June 10, 2015 to June 09, 2016 Design Engineer: ANDERSON ENGINEERING Subdivision: NETTLETON ACRES #1 Site Legal Address: NETTLETON ACRES #1 LT 1 G:2439 Owner/Address: BROCKWAY KELLEY E 9410 NETTLETON DR ANCHORAGE AK 995076006 Site Mailing Address: 9410 NETTLETON DR, Anchorage This permit is for the construction of: Lot Size in Sq Ft: Total Bedrooms: 611715- -�;! So 53140 6 N Disposal Field N Septic Tank N Holding Tank N Privy N Private Well N Water Storage All construction must be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80). 3. The wastewater code requires inspections during the installation. The engineer must notify the Development Services Department at least 2 hours prior to each inspection. Provide notification by calling (907) 343-7904 (24 hours). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must either: A. Open and Close on the same day. B. Covered, sealed, and heated to prevent freezing. Received Issued By By: Date: C —J// —/S Date: fK !� MUNICIPALITY OF i.. ,�,� Community Development Department ��, Development Services Division I/bnlSite Water & Wastewater Program H RUSH! ANCHORAGE (a( JUN o 9 2015 Phone: Fax: ON-SITE SEWER/WELL PERMIT APPLICATION Parcel I.D. 015-062-62 Property owner(s) Kelley E. Brockway Mailing address 9410 Nettleton Drive Anchorage, AK 99507 Site address Same Day phone Legal description (Sub'd., Block & Lot) Nettleton Acres #1, Lot 1 Legal description (Township, Range & Section) Lot Size 53,140 Sq. Ft. Number of Bedrooms Six APPLICATION IS FOR: APPLICATION IS AN: TYPE OF DWELLING: (N all that apply) Absorption Field ❑J( Initial ❑ Single Family (SF) ❑x (w/wo ADU) Septic Tank ElUpgrade [ADuplex (D) ElHolding Tank ElRenewal ❑ Multiple Dwellings ❑ Privy ❑ (SF and/or D) Private Well ❑ Water Storage ❑ THIS APPLICATION INCLUDES A VARIANCE / WAIVER REQUEST FOR: Dis tance: I certify that the above information is correct. I further certify that this is in accordance with applicable Municipal Codes. (Signature of property owner or authorized agent) 1-x..51\ Permit/Rush Fees: t%g +3%qo= 91o,yO Waiver Fees: Date of Payment: le q IS rrjoi Date of Payment: Receipt Number: 001It3a Receipt Number: Permit No. Osels 11 U9 Waiver No. Permit App_" :-:L..:c. ANDERSON ENGINEERING P.O. BOX 244773 ANCHORAGE, AK 99524 522-7773 677-7766 FAX June 8, 2015 Municipality of Anchorage Development Services Department On -Site Water and Wastewater Program 4700 Elmore Road Anchorage, AK 99519-6650 Subject: Lot 1, Nettleton Acres Subdivision No. 1 Septic System Design and Permit Application Impacts to Adjacent Properties Dear Onsite Services Engineer: The absorption system on the subject lot has failed and must be replaced prior to the issuance of a COSA. We are therefore requesting a permit be issued for the upgr@de of the septic system to accommodate the six -bedroom home on the lot. The new absorption trench will be constructed at the alternate site approved by the permit issued in 2006. The attached Site Plan and backup documentation identify the location and configuration of the existing and proposed septic system. The existing Advantex Treatment Tank has been in service since 2006 and is suitable for continued use according to maintenance records. The existing absorption trench will remain in service and be connected for future us with a flow diverter valve. We have also identified the locations of the existing well on this lot and adjacent lots. No conflicts exist between the proposed septic system and the wells or water services on this or adjacent lots. Drainage arrows are shown indicating the current drainage patterns. The ground surface in the area of the proposed trench is virtually flat. The drainage patterns will be maintained after construction. The test hole utilized during the initial design indicated Silty Gravel (GM) in the absorption zone of the trench. The percolation rate was determined to be 12 minutes per inch. No groundwater was encountered during the placement of the test hole and none has was found during the monitoring period. The previously approved design however was completed with a water table at 11' below the surface. We have designed the new trench with an application rate of 2 gallons per day per square foot which is much more conservative than the previous design. We are proposing to place a 53' long trench by 5' wide with a 3' effective depth. The total depth of the system will be 6' with the distribution line at 3' below the existing surface. Lot 1, Nettleton Acres #1 June 9, 2015 Page Two The ground surface on the lot in the area of the new trench is flat. The trench will be placed parallel to the contours of the ground as much as possible and in conformance with design criteria. A minimum of 100' will be maintained between all components of the septic system and the proposed well and from any surface water in the area. If the system is constructed in accordance with our design the following statements apply: The system, if constructed as designed, will have no adverse impact on the wells in the area or those to be constructed in the future. 2. The system, if constructed as designed, will have no adverse impact on existing septic systems in the area or those to be constructed in the future. 3. The system, if constructed as designed, will have no adverse impact on reserve space, either surface or subsurface, on any lots located in the area. 4. The system, if constructed as designed, will have no adverse impact on drainage patterns in the area. The current drainage pattern will, be maintained. Sincerely, xt'-e Michael E. Anderson, P.E. Attachments i 4 I I I r ------------------------------------J 5 --------------------------- I I I n / I C C 4C 13 I Ir Exieling � well \ - -4�--------------------- \ / \ f \I \ \ i ��Exiatin9 2 I wWing ell E49in9 / 1 \ Well ® / / � / I / 15 `�Y. x` I Existing 16 C CC /' ---' 49th •�/ /.....e. .... .... ......... ...` ;MICHAEL E. ANDERSON Q+ AF 19 j \\ \` •��fr No. CE -4361 1\ I E ®1 n9 I 2 \, REA MAP SCALE i" = 100' 3AIa0 NO1311DN 0 N ,LZ'84L MJU0.00 N — — — 1N3W3SV3 3 V 1 ,0[ 1N3W3SV3 NOINJ0313 ,£Z/ 1 1 JxnA O O f,✓d/ w x w fY' U vy \ 3 mt \ > �c inua \, n XVC�Xy9 \V\So y oc oa �Wn V ho�0 Np CN Mm c c E N 3 > 3 F L] o yr �j n3 z W ('J F 3x r'():l 0 N 3 > 3 F L] o 3°° z Z _ O N 0 U /r uj9 J �0� J n LOT 1, NETTLETON ACRES SUBDIVISION NO. 1 DESIGN FACTORS: SYSTEM REQUIREMENTS Six Bedroom Home 5' Wide Trench System Perc. Rate: 12 Min./Inch Existing Advantex Treatment System Application Rate: 2 GPD/SF 3' Drainfield Rock 6 Bedrooms' 150 GPD/Bedroom = 900 SF Absorption Area 900 SF/2 GPD/SF/5 SF/LF` .58 (Red. Factor) = 52.2 LF Trench Length THEREFORE: Construct a 53' Long x 5' Wide x 3' Effective Depth Absorption Trench. Flow Line Elevation in Trench to be 3' Below Original Ground Surface. Total Depth to be 6' Below Existing Ground. Provide 3' Cover Over Trench and 4' of Cover Over Tank. Place Flow Diverter Valve and Connect Existing Trench for Future Use. 3' Cover (Minimum) 5' TYPICAL 5' WIDE TRENCH SECTION (NO SCALE) _A NOTE: Grade Area Over Trench to Drain Away. Minimum 6' Separation From Bedrock. Minimum 4' Separation From Groundwater. I Minimum 100' Separation From Wells in the Area. Minimum 100' Separation From Surface Water or Streams: Municipality of Anchorage Development Services Department Building Sally Division - OnSlte Water and Wastewater Program, 4700 Bragaw St. P.O. Box 196650 Anchorage. AK 995198850 Page I of '3 www.clanchoragesk.us (907) 3417901 ON-SITE WASTEWATER DISPOSAL SYSTEM AND/OR WELL INSPECTION REPORT Permit Number. SWO60166 PID Number. 015-062.62 " Kelly Brockway Wastewater System: 0 New ❑ Upgrade A . 9410 Nettleton Dr., 99507 ABSORPTION FIELD Plnrr '" CO e.d o 5 O D,Fp Tn m Volim Tr,rrn O 8a O MW4 D D,tr LEGAL DESCRIPTION 0 �"a s o G,o,F- n. Bo LO11 Nettleton Acres #1 DWMW Poo b—ftW1«fir 711. 2.8 Gn a.o,i e~i Py. 3.11 Ft, Ft iowrrp ROV S,ceart FrW MatrW"ga Gn LWVM 1.0 Fl. 32.0 Fl. Well: [I New [I Upgrade G"Prrra" r..b Cold 1 NA 5.0 Ft. FL Gi� (Pn .i A B. Q T" D,qn Caws w 7",brorp,o",n, 276 Pp MrwW ASTM D3034 private F. Ft Fr Dr Dr, DFM, 2003 sM WawL w xru..r Red Dog Masonry DmxrMw, 620/06 Ft PMS G.M°1«,w"" G� TANK GPM FI. Fl SEPARATION DISTANCES ❑ Septic ❑ Holding ❑ ST ER FA—dy—ah—Te-x-j 0 othBr To From Septic Tank Absorption Field Lift Station Holding Tank ub(r/PMata Serer Lal, Anchorage Tank & Welding 2500r Gal MM RunEr r WtprvnFr+e VM 128 145 NA NA 102 steel 2 swf. wa too+ 100+ NA NA LIFT STATION Laue 50+ 40+ NA NA NA Gr 'Ptnp an lMrtK 'Fury rr M.MK Iglr,Mr ramM F� 120 20+ NA NA M r M cMla+t or,n NA NA NA NA Pump Mlle a Moor t:rrnirrai lr-p F pnornra W R, AdvanTex control panel is inside the house. BENCH MARK lorrm.w D.awoor. top of manhole rrran 103.32 FL . Engineer's Stamp Inspections performed by: Cindy W. Ellis. P.E. Dates: 10 620106 4 2 620/06 OF •��,..........,q� Devel oprnenj Services Department Approval Conditional Approval Date: lot• mr� ✓CM o 1lt5 f;le� C12, W. Ellis ; C>i Ot.�S t-'• Reviewed and approved by: Date- :' OCE -16577 � rx.. rruel ••••.. ' "�ESSIONrJ-GCS•' moi.-� �y ST1 6 Garage I o S s FCO � \N • � / Driveway I— � dio vo 5BR House I/ o ti I WELL S 8959=E 288.41' AS -BUILT \ / / i ST1 14.0 13.4 MH 15.9 16.0 C01 19.0 19.7 19.3 MT1 21.5 21.3 21.6 CO2 43.1 42.9 43.1 MT2 39.9 40.2 40.6 O MT2 CO2 0) 3V I ti Z I C01 H1 I ansa MT1 MH " C I s 0 �y ST1 6 Garage I o S s FCO � \N • � / Driveway I— � dio vo 5BR House I/ o ti I WELL Nettleton Acres #1, Lot 1 Record Drawing of Septic Installation Kelley Brockway Parcel ID, 015-062-62 Permit No. SWO60166 Cindy W. Ellis, P.E. January 8, 2008 Scale 1'- 40' � I / y�W Based upon a survey by \` ` 05a Jeff Gastaldi, LS -0091 !,. �' April 27, 2007 / q,. 31.41' 20.00' \ Watkins Engineering, Inc P.O. Box 110443 Anchorage, AK 99511-0443 Phone: (907) 349-1851 Fax (907) 349-1934 OF A QGjr 49 TH 7µi ............................... �.-.Y.W..VitEWS.: W --S- CED CE • 105r/ .a 'o •• ...... •mss O A B C ST1 14.0 13.4 MH 15.9 16.0 C01 19.0 19.7 19.3 MT1 21.5 21.3 21.6 CO2 43.1 42.9 43.1 MT2 39.9 40.2 40.6 Nettleton Acres #1, Lot 1 Record Drawing of Septic Installation Kelley Brockway Parcel ID, 015-062-62 Permit No. SWO60166 Cindy W. Ellis, P.E. January 8, 2008 Scale 1'- 40' � I / y�W Based upon a survey by \` ` 05a Jeff Gastaldi, LS -0091 !,. �' April 27, 2007 / q,. 31.41' 20.00' \ Watkins Engineering, Inc P.O. Box 110443 Anchorage, AK 99511-0443 Phone: (907) 349-1851 Fax (907) 349-1934 OF A QGjr 49 TH 7µi ............................... �.-.Y.W..VitEWS.: W --S- CED CE • 105r/ .a 'o •• ...... •mss O FCO FINAL GRADE ST1 103.0 103.11 Q r— 103.32 TEX MAN - 99.67 V I I 1 AX-20ADVAPOD I I HOLE STEEL ADVANTEX TANK 99.05 2500 GALLON E , MT1 C01' ".FINAL GRADE= 102.1-102.6 MT2 CO2 RA I MM — 4"0 PIPE FILTER FABRIC SEWER ROCK 95.58 32' — NOTE: RELATIVE DEPTH OF TRENCH TEST HOLE = 88.50 N.T.S. WATER @ 90.50 Ml 95.48 NOTE: ORIGINAL GRADE _ 101.00-101.50 AS -BUILT Nettleton Acres #1, Lot 1 c600000pppp OF At Record Drawing of Septic Upgrade . ............ Kelley Brockway Parcel ID: 015-062-62 Watkins Engineering, Inc. oo p;O�P49TH .7 p Permit No. SW060166 4.,.�...' ///// �GTllGL7i �lf64;,....p Q . •, CJ�DY W. ELLIS Q 4p� : • ce - iosn 4 ���pp00000000���o Cindy W. Ellis, RE P.O. Box 110443 January2008 Anchorage, No Sc Phone: ( 07) 349-1851, Fa (907) 349-1934 s 1'I=40' 92-114 NETTLETON ACRES, UNIT 1 LOT 1 53,140 S.F. BUILDING DETAIL SCALE: ll' -20' GASTALDI LAND SURVEYING, LLC JEFF A. GASTALDI, R.L.S. 4726 WEST BETH AVENUE ANCHORAGE, ALASKA 99502 PHONE 248-5454 GRID , 2439 F.B. 07-04 DATE 4/27/2007 JOB NO. NA511 288.44' SEPOC Sys?tm SH[p •• O 4p.v � 1•x�e 0.' �3. Si t7: i i \ R� ?00.0.000'1 . N � I HEREBY CERTIFY THAT I HAVE SURVEYED THE PROPERTY DEPICTED ABOVE AND THAT NO ENCROACHMENTS EXIST EXCEPT AS INDICATED. IT IS THE RESPONSIBILITY OF THE OWNER TO DETERMINE THE EXISTENCE OF ANY EASEMENTS, COVENANTS OR RESTRICTIONS WHICH DO NOT APPEAR ON THE RECORDED SUBDMSION PLAT. UNDER NO CIRCUMSTANCES SHOULD ANY DATA HEREON BE USED FOR CONSTRUCTION OR FOR ESTABLISHING BOUNDARY OR FENCE LINES. ANCHORAGE RECORDING DISTRICT, ALASKA NOTE: NO CORNERS SET THIS DATE 63.0' N O I O 52.7' I lz GRAVEL DRIVE .*mss\■11• � ll'<* ......... .�F.. q� 01 �1 Th ; *�0 • e.r A. G°s1°IdiAir v : LS -6091 1 AV • rOJesslo,o-ol, ••f�0Rik;;** cr 10 20'.0 MUNICIPALITY OF ANCHORAGE Development Services Department I n 1) I I �-0-d On -Site Water 8 Wastewater Program 4700 South Bragaw Street P.O. Box 196650, Anchorage, AK 99519-6650 (907) 343-7904 ON-SITE WASTEWATER DISPOSAL SYSTEM PERMIT Initial Permit Number: SWO60166 Legal Description: NETTLETON ACRES #1 LT 1 Design Engineer. 0844 WATKINS ENGINEERING Owner Name: KELLY BROCKWAY Owner Address: P.O. BOX 232445 ANCHORAGE. AK 99523 - Date Issued: Jun 19, 2006 Expiration Date: Jun 19, 2007 Parcel ID: 015-062-62 Site Address: Lot Size: 53140 SQ. FT. Total Bedrooms: 5 Permit Bedrooms: 5 This permit is for the construction of: E Disposal Field [✓ Septic Tank Holding Tank E] Privy Ej Private Well ❑Water Storage All construction must be In accordance with: 1. The attached approved design. 2. All requirements specified In Anchorage Municipal Code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations ( 18AAC72 ) and Drinking Water Regulations ( 18AAC80 ). 3, The engineer must notify DSD at least 2 hours prior to each Inspection. Provide notification by calling (907) 343-7904 (24 hours). ( Not required for a Water Supply Permit only). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must be either: A. Open and closed on the same day. B. Covered, sealed, and heated to prevent freezing. Received By. Date: _6, Issued By. \ Date: G Municipality of Anchorage .� Development Services Department Building Safety Division On -Site Water and Wastewater Program $ • C,. 4700 Bragaw Street P.O. Box 196650 Anchorage, AK 99519-6650 www.muni.org/onsite 343-7904 �encwe�L ON-SITE SEPTICMELL PERMIT APPLICATION FOR A SINGLE FAMILY DWELLING Parcel I.D. D 15 - C) 10,9 Property Mailing Ala phone 105g-1410 Code gG!5':93 Site address 941 r) tic 'IZl?zo Df' y& Zip Code Legal description (Sub'd, Block &Lot) J� tfA ter kjrj>'o S 441 COT I Legal description (Township, Section & Range) Lot Size 531gQ Sq. Ft. THIS APPLICATION IS FOR (®all that apply): Absorption Field E3_ Septic Tank 0' Holding Tank ❑ Privy ❑ Private Well ❑ Water Storage ❑ Number of Bedrooms C-5 THIS APPLICATION IS AN: Initial E3_ Upgrade ❑ Renewal ❑ certify that the above information is correct. I further certify that this application is being made for a Single Family DAelling an" in accordance with applicable Municipal Codes. (Signature) f property owner or authorized agent) Permit/Rush Fees: Date of Payment: Waiver Fees: Date of Payment: Receipt Number: �6) q �30 Receipt Number: (Rev. 7 tros) MUNICIPALITY OF ANCHORAGE Development Services Department On -Site Water 6 Wastewater Program 4700 South Bragaw Street P.O. Box 196650, Anchorage, AK 99519-6650 (907) 343-7904 ONSITE WASTEWATER DISPOSAL SYSTEM / WATER SUPPLY PERMIT Initial Permit Number: SWO50182 Legal Description: NETTLETON ACRES #1 LT 1 Date Issued: Jun 17, 2005 Expiration Date: Jun 17, 2006 Parcel ID: 015-062-62 Design Engineer: 0003 S & S Engineering Site Address: Owner Name: KELLY BROCKWAY Lot Size: 53140 SQ. FT. Owner Address: P.O. BOX 232445 Total Bedrooms: 5 Permit Bedrooms: 5 ANCHORAGE. AK 99523 - This permit Is for the construction of: ❑✓ Disposal Field ❑? Septic Tank ❑ Holding Tank ❑ Privy ❑✓ Private Well ❑ Water Storage All construction must be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal Code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations ( 18AAC72 ) and Drinking Water Regulations (18AAC80 ). 3. The engineer must notify DSD at least 2 hours prior to each Inspection. Provide notification by calling (907) 343-7904 (24 hours). ( Not required for a Water Supply Permit only). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must be either: A. Open and closed on the same day. B. Covered, seated, and heated to prevent freezing. 5. The following special provisions. -THE UPPER SIX INCHES OF THE MOUND SYSTEM MUST CONSIST OF TOP SOIL AND THE MOUND MUST BE VEGETATED SUFFICIENTLY TO PREVENT EROSION. n 4j tjjob- ReJ tS -j^J SJt3m,Trzo 61 WAI-ko.Vs EA',,ve Rj� jDwrco ogpA%f 11 � r ZGOb 4Z. AN -jJvavTtx 'N Rs-awnr:rA -'WCA, . cjga' ovib o yq' Received By. Date: % Z( 0S Issued By. ML Date: �, /L1•r Mu ildpality UAttehoegige • bevelopment Services Department Building Safety Division On -Site Water and Wastewater Program 4700 South Bragaw St. P.O. Box 196650 Anchorage, AK 99519-6650 www.ci.anchorage.ak.us (907)343-7904 ON-SITE SEWER/WELL PERMIT APPLICATION FOR A SINGLE FAMILY DWELLING Parcel I.D. _ Q kS- O 1,9 7- — to 7- Permit Number SW Property rMW (phone 565— q 10(0 Mailing address f Q. 80X a3agy-5 . %� Zip Code 995 Site address "13eJD Nee TLZ 1-00 T)r. Zip Code Legal description (Lot, Block & Sub'd.) _ LA i Nzktl� ACtZLSi S�� Legal description (Section, Township & Range) Lot Size S -6, � h6 Acres/Sq.Ft. Number of Bedrooms THIS APPLICATION IS FOR: Sewer Only ❑ Well Only ❑ Sewer and Well JR1 Water Storage ❑ Sewer Upgrade ❑ THIS PROPERTY CONTAINS: Hot Tub ❑ Jacuzzi ❑ Swimming Pool ❑ Water Softening Unit ❑ Therapy Pool ❑ 1 certify that the above Information is correct. I further certify that this application Is being made for a Single Family Dwelling and Is in accordance with applicable Municipal Codes. ... .. , _ S L S ENGINEERING (Signature of property owner or authorized agent) Alas Eagle � River, Aloka 99517 Permil/Rush Fees: Date of Payment: Receipt Number. (Rev. 09/04) Dale of Payment: Receipt Number: Watkins Engineering, Inc. P.0 Box 110443, Anchorage, AK 99511 (907)349-1851 cwellis@gci.net April 17, 2006 Municipality of Anchorage Development Services Department Building Safety Division On -Site Water and Wastewater Program P.O. Box 196650 Anchorage, AK 99519-6650 RE: Nettleton Acres #1, Lot 1 Proposed Septic System Design Change To Whom It May Concern: Permit No. SW0500182 was issued on June 17, 2005 to install a septic system on the subject lot. It is proposed to change the design from an Intermittent Dosing Sand Filter to an AdvanTex AX20 advanced wastewater treatment system. The proposed design is based upon a test hole dug by Roger Shafer, P.E., of S&S Engineering on March 19, 1992. The hole was dug to 13.0 ft with no water encountered. After a 7 day monitoring period, no water was detected, but on June 8, 1992, water was detected at 11 ft. The proposed design is based upon a 5 ft separation to this level, with the bottom of the drainfield at a maximum depth of 6 ft. On April 11, 2006, the test hole was dry. The proposed drainfield will be installed in a silty gravel layer between 3.0 ft and 6.0 ft. A percolation test was conducted in March 1992 by S&S between 5.5 ft and 6.5 ft and resulted in a rate of 16 minutes per inch. An application rate of 4.0 gpd/ft' is used in the design. The soil log is attached. The drainfield is designed for 6 bedrooms, which is over -sized. The proposed house is 5 bedrooms, and the tank is sized for 5 bedrooms, at 2500 gallons. One AX -20 pod is planned for the system, which has been approved by the manufacturer, Orenco. The system will be maintained by Anchorage Tank & Welding, monitored 2417 with the VeriComm system, and inspected at least twice annually. If conditions dictate, another AX -20 pod will be installed. There is space available on site for a reserve drainfield. Proposed Septic System Design Change for Nettleton Acres Of Lot 1 Watkins Engineering, Inc.;April 17,2006; page 2 Proposed Soil Absorption System: 6 Bedrooms x 150 GPD/BR = System Type: Application rate: 900 GPD / 4.0 gpd/ftz = Maximum Depth: Effective Depth: Reduction Factor: Proposed Length: Absorption Area: 900 GPD Shallow trench 4.0 gpd/ ft? 225 ft? required 6.0 ft 3.0 ft 0.58 30 ft 258 ft' There are no surface waters or private wells within 100 ft of the proposed septic system. There are no slope concerns. I am not aware of any adverse effect that this upgrade would have on any adjacent properties' water and wastewater treatment needs. Thank you for consideration of this permit application. If you have any questions or need further information, please call me at 349-1851. Yours truly, Cindy .Ellis, P.E. President NETTLETON ACRES I 3 ,-I / I Approx well location \ `-------7m4M Esmt \ %\ well 14 1 \ \ Proposed /� septic system H . O Septic \�/L Area \ F Proposed \ \ 5 BR \ House 15 \ \ Existing Wel \I� i 19 \--� Silver Crest Subdivision 20 \ \. Septic Area \ \ / I ApProz well lions 1 I \ \ 0 z z Panorama' Subdivision 3 2 septic IA area Block 2 I Block 1 septic area 8A I septic I I area 6 _I Nettleton Acres #1 Lot 1 Proposed QpvS�iuO 0�� OF A C 040 Septic Installation -Site Plan Watkins Engineering Inc Kelley Brockway ooP� '•........''9d' �p �: ' Parcel IU 015-062-62 o p „c?: 49 TH CO 0�1�i l.. ....... 0 : '. ciN Y W. ELLIS O Opo '•. E - 10577 Cindy W. Ellis, P.E. P.O. Box 110443 April 14, 2006 Anchorage, AK 99511-0443 Scale 1' - 100 Phone: (907) 349-1851 Fax: (907) 349-1934 Nettleton Acres #1, Lot 1 Proposed Septic Design Kelley Brockway Parcel ID: 015-062-62 Cindy W. Ellis, P.E. April 14, 2006 Scale Y - 40' Watkins Engineering, Inc. P.O. Box 110443 Anchorage, AK 99511-0443 Phone: (907) 349-1851 Fax (907) 349-1934 �POF A 4p ,� ........... qs p0o 49 TH '9„i ....`�......... CI� W. ELUS CE - 10577 i •� G \ DESIGN DETAILS 6 BR, 900 GPD \ 4.0 gpd/ft2 _ 'S. Requires 225 1112 W Shallow Trench IIII 5 ft wide Vq p W 3.0 ft effective (���TH RF=0.58 30 ft deep sN Z Max E ft T F] OC Abs. Area = 258 ft2 Proposed .W_I CO & MT I Proposed W Garage I Z Proposed 2500 gal steel AdvanTex tank w/ AX -20 pod. Propose \ DrK*"y 51311 House \ i \ I Test Hole #1 I S&S Engr Proposed 3-25-92 Trench / Organics 0.5 4' perf ' 3.0 pipe 100' Existing Well GM 3.0 R sewer rock 6.0 \01X\ 1 Water 11.0 s ca�cGpy� \ / / @11' on s O55Og0 6-8-9213.0 BOH Nettleton Acres #1, Lot 1 Proposed Septic Design Kelley Brockway Parcel ID: 015-062-62 Cindy W. Ellis, P.E. April 14, 2006 Scale Y - 40' Watkins Engineering, Inc. P.O. Box 110443 Anchorage, AK 99511-0443 Phone: (907) 349-1851 Fax (907) 349-1934 �POF A 4p ,� ........... qs p0o 49 TH '9„i ....`�......... CI� W. ELUS CE - 10577 i •� G June 10, 2005 ROBERT C. COWAN, P.E. CML ENGINEERS (907) 694.2979 FAX(907)694-1211 HEALTHALRHORITY MUNICIPALITY OF ANCHORAGE APPROVALS Development Services Department P.O. Box 196650 Anchorage, AK. 99519 SEWERS WATER MAw UTENSIONS REFERENCE: Lot 1, Nettleton Acres S/D #1 SEWERSWATER It is requested that you issue a permit to install well & septic system to serve the INSPECTION proposed five bedroom dwelling on the referenced property. A test hole was excavated and a percolation test was performed. The approximate location ENGNEERWGSTUOIES of the test hole is located on the attached site plan. At the time of excavation 3/19/92 water ANOREPORTS was not found. Ager seven days of ground water monitoring the test hole was found to be dry. On 6/8/92 water was found at 11 feet and then not found again on 6/15/92. WELLINSPECTION We do not anticipate any adverse effects on neighboring wells, septic systems, reserve SPLOWTEST areas or drainage patterns by the installation of the proposed septic system. The construction of this system will not prevent any future development on any of the adjacent properties. SITE PLANS If you require additional information, please contact us. Sincerely, ROAD DESIGN / NEST Robert C. Cowan, P.E. RCC/jhm Enclosure PERCMTIO, TEST STRUCTURAL S MECKANIGY INSPECTIONS ON SITE WASTEWATER OISPOSALSISTEM DESIGN 17034 NORTH EAGLE RNER LOOP • SURE 204 • EAGLE RNER, ALASKA 99577 SITE PLAN o ti r DESIGN " = 60' SCALE �IAQ C ~ \D=N �f 900 f.� i •?.. eO 0Z0 \ SonSewer Esmt 85.00 m , O � _ owl CD 9 Z o ., cry •..- _•;': / NN O I� / rn10 F Z� 8N mp - gZ +9 Pi y0;o 0 co -4 f-0 R„ / zV T.z0 O D 0 �A fJ " ci ^"" .4 N N d Go P1O U- CPO sm� � osv Ul zmtn"o:,h Min N I z x C) NON 0-00 t23 Ent) a ►3 .O ti v� m z v 'n~ < N e O � + Oo A V\v W oA y :p 00 o z NETTLETON Drive CU)t I d7 O N �f 900 f.� i •?.. eO 30' SonSewer Esmt 85.00 m , owl CD 9 Z o ., cry •..- _•;': I" = 60' DESIGN SITE -PLAN SCATr- g F 0NWC i,'•'� = � rn -n Zorn u �IYA 9IX m PIS �i v Nay g C/) r gg i 9 �ooilt�� `x o Ln �� n (A z i' a .• 0 p o p t� 1 0 M. ;0 o o C) . o oil z z cn m � p ` � j R�» ,,,_, $ � » M v w 0 cn F-Fa z wLn �;. �8 " osmo �•�;y'yj s�1�.1 f� by �ps N • ai! �'�n N 'millndg� o� it Wit. G^,%S\•may. •. � t+ (p) �" n i jOP 8 ��•,i oy^' / 7 :. V a Municipality of Anchorage DEPARTMENT OF HEALTH 6 HUMAN SERVICES 825 "L" Street, Anchorage, Alaska 99502-0650 SOILS LOG — PERCOLATION TEST PERFORMED FOR: K—�c--1'�+��_ 7 ��1-1�-Y' 1 DATE LEGAL Section: vR %W- -1 1 Vcr-r I L, M 9- lo - ll 10 „ 12 or • r 13 -1 I Q_3 0. {•1', 14 15 16 17 18 19 pay pal 6/15/9-2 / 5 N - WAS GROUND WATER , I ENCOUNTERED? IV S IF YES, AT WHAT L O DEPTH? P /1' G A/4;LE Depth No wua e� Manw�-, , ilarin07 �— OiIC 4� SITE PLAN s 20 I ' / uPERCOLATION RATE ���� (minuteymch) PERC HOLE DIAMETER TEST RUN BETWEEN � L"L-fT AND LC!17�FT COMMENTSv4,E=> PERFORMED BY:17034 Eagle River Loop Road No, 204 I ' J CERTIFY THAT THIS TEST WAS PERFORMED IN Eag a River, Alaska 99577 ACCORDANCE WITH ALLSTATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE. DATE: 72-M (Rev. 4185) WOO- WE= s 20 I ' / uPERCOLATION RATE ���� (minuteymch) PERC HOLE DIAMETER TEST RUN BETWEEN � L"L-fT AND LC!17�FT COMMENTSv4,E=> PERFORMED BY:17034 Eagle River Loop Road No, 204 I ' J CERTIFY THAT THIS TEST WAS PERFORMED IN Eag a River, Alaska 99577 ACCORDANCE WITH ALLSTATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE. DATE: 72-M (Rev. 4185) MUNICIPALITY OF ANCHORAGE Development Services Department On -Site Water & Wastewater Program 4700 South Bragaw Street P.O. Box 196650, Anchorage, AK 99519-6650 (907) 343-7904 ON-SITE WASTEWATER DISPOSAL SYSTEM / WATER SUPPLY PERMIT Renewal Permit Number: SW040030 Legal Description: NETTLETON ACRES #1 LT:_ 1 Design Engineer: 0003 S & S Engineering Owner Name: John Faschan Date Issued: Mar 15, 2004 Expiration Date: Mar 15, 2005 Parcel ID: 015-062-02 Site Address: q-bo5D N L--rxA-_7u0 'Dv -- Lot Size: 53140 SQ. FT. Owner Address: 7431 Solarset Cir. Total Bedrooms: 3 Permit Bedrooms: 3 Anchorage , AK 99507 - This permit is for the construction of: Q Disposal Field ❑D Septic Tank ❑ Holding Tank ❑ Privy ❑✓ Private Well ❑ Water Storage All construction must be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal Code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72 ) and Drinking Water Regulations (18AAC80 ). 3_ The engineer must notify DSD at least 2 hours prior to each inspection. Provide notification by calling (907) 343-7904 ( 24 hours ). ( Not required for a Water Supply Permit only). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must be either: A. Open and closed on the same day. B. Covered, seated, and heated to prevent freezing. Received By. Issued By Date: Y/2-7 A it g 42"4 Date: Municipality of Anchorage • Development Services Department Building Safety Division On -Site Water and Wastewater Program 4700 South Bragaw St. P.O. Box 196650 Anchorage, AK 99519-6650 www.ci.anchorage.ak.us (907)343-7904 ON-SITE SEWER/WELL PERMIT APPLICATION FOR A SINGLE FAMILY DWELLING Parcel I.D. OIS- cf"-7— G Z Permit Number SW 0401 ?w Property owner(s) 1 C) H 4 �AS C#1, i n1 Day phone I 2177 -O(o OS Mailing address (1) -741 ( SAIc, cc, t j [t rr LD Arrx.ht, to,k.-F 15 Sal Mailing address (2) Zip Code Legal description (Lot, Block & Sub'd.) N e AAilo ra Acztr S -A I LT 1 Legal description (Section, Township & Range) Lot Size 53 ILII Acres4OD THIS APPLICATION IS FOR: Number of Bedrooms 3 Sewer Only ❑ Well Only ❑ Sewer and Well Q� Water Storage ❑ Sewer Upgrade ❑ THIS PROPERTY CONTAINS: Hot Tub ❑ Jacuzzi ❑ Swimming Pool ❑ Water Softening Unit ❑ Therapy Pool ❑ certify that the above information is correct. I further certify that this application is being made for a Single Family Dwelling and is in accordance with applicable Municipal Codes. or authorized agent) Date of Payment: Receipt Number: 4Q 1 7 3 Receipt Number: (Rev. 12/00) MUNICIPALITY OF ANCHORAGE Development Services Department On -Site Water & Wastewater Program 4700 South Bragaw Street P.O. Box 196650, Anchorage, AK 99519-6650 (907) 343-7904 ON-SITE WASTEWATER DISPOSAL SYSTEM I WATER SUPPLY PERMIT Renewal Permit Number: SW030050 ',Legal Description: NETTLETON ACRES #1 LT 1 Date Issued: Mar 18, 2003 Expiration Date: Mar 17, 2004 Parcel ID: 015-062-62 Design Engineer: 0003 S & S Engineering Site Address: Owner Name: John Faschan Lot Size: 53140 SO. FT. Owner Address: 7431 Solarset Cir. Total Bedrooms: 3 Permit Bedrooms: 3 Anchorage , AK 99507 - This permit is for the construction of. [; Disposal Field G Septic Tank ❑ Holding Tank F� Privy [j Private Well Water Storage All construction must be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal Code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations ( 18AAC72 ) and Drinking Water Regulations ( 1 BAAC80 ). 3, The engineer must notify DSD at least 2 hours prior to each inspection. Provide notification by calling (907) 343-7904 (24 hours). ( Not required for a Water Supply Permit only). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must be either: A. Open and closed on the same day. B. Covered, sealed, and heated to prevent freezing. Received By: Issued By: Date: 3 ZWlo3 Date: / Oj Municipality of Anchorage • Development Services Department Building Safety Division i Onsite Water and Wastewater Program 4700 South Bragaw St. P.O. Box 196650 Anchorage, AK 99519-6650 www.ci.enchorage.ak.us (907) 343-7904 ON-SITE SEWERMELL PERMIT APPLICATION FOR A SINGLE FAMILY DWELLING Parcel I.D. o[ S-- D (�- a-- (�^ a Permit Number SW 03Wa W Property owner(s) , -V, n t:f:L5c4V-'- ►1 Day phone Mailing address (1) 7N 3 i �C �A ( ,e + C Mailing address (2) /.1CAr'etaAe N Zip Code 9q5a7 Legal description (Lot, Block & Sub'd.) ETTL F_ r0v ACRES # / L or / Legal description (Section, Township & Range) Lot Size S��, 111 D Acres/ .Ft THIS APPLICATION IS FOR: Number of Bedrooms 3 Sewer Only ❑ Well Only ❑ Sewer and Well Water Storage ❑ Sewer Upgrade ❑ THIS PROPERTY CONTAINS: Hot Tub ❑ Jacuzzi ❑ Swimming Pool ❑ Water Softening Unit ❑ Therapy Pool ❑ I certify that the above information is correct. I further certify that this application is being made for a Single Family Dwelling and is in accordance with applicable Municipal Codes. Permit Fees: %�%b • pC> Date of Payment: Receipt Number: (Rev. 12100) Waiver Fees: Date of Payment: Receipt Number: R- F:�jao A L_ - 3(i.0 /o3 .10/21/2003 12:43 FA.[ EDC, Inc. rtR 45, C• +f:..P%moi �,;M ;•�..�� U��w:ir.;r»rti taf I-l�sftia alta tjutn�n 5�;vi�a 0251! Stre -t P.O. P_ox 1x03950 Anchnrarye. Alaska 03519 GG50 Rick Mystrom hap thrma tanchuraye a� us Mayor Q002/00;" 9 Permit Number: 4SW 0g00Sa Date Of Issue; 3-18-02 Parcel Identification Number: 015-062-62 Date Started: °_v=9-03 Date Completed: ' 9-03 is well located at approved permit location? ® Yes ❑ No Legal Description: NPltleton Acres #1 Lot 1 Property Owner Name & Address: J--hn Faschan 7431 Solarset Cir. Anchorage. Alaska 99507 Borehole Data: Soil Type, Thickness & Water Strata Depth (ft) from To Method of Drilling ® air rotary ❑ cable tool Casing type: steel stick-up 0 2 Wall Thickness: ,250 inches gravelly silt 2 15 Diameter: 6 inches Depth: 141 feet silty gravel 15 41 Liner Type: gra vellysilt silty sand siltygravel gravelly silt 41 55 Gl 93 55 61 93 104 Diameter: inches Depth: feet Casing stickup above ground: 2 feet Static water level (front ground level): 77 feet Pumping level: 141 feet after 2 hours pumping 20 gpm gravelly silt wet 104 138 Recovery Rate: 20 gpm water sand & gravel 138 141 Method of Testing: airlift Well Intake Opening Type: ® Open End ❑ Open Hole ❑ Screened Start feet Stopped feet ❑ Perforations Start feet Stopped feet Grout Type: bentonite * 8 Volume: I Depth: Start0 feet Stopped 7 feet Pump: Intake Depth_ feet Pump size _ lip Brand Name Well Disinfected Upon Completion? ® Yes ❑ No Method of Disinfection: Comments: Well Driller: Alpine Drilling & Enterprises PO Box 110496 Anchorage Alaska 99511 Attention: The well driller shall provide a well log to the property owner within 30 days of completion and the property MUNICIPALITY OFANCHORAGE Development Services Department On -Site Water 8 Wastewater Program 4700 South Bragaw Street P.O. Box 196650, Anchorage, AK 99519-6650 (907) 343-7904 ONSITE WASTEWATER DISPOSAL SYSTEM / WATER SUPPLY PERMIT Initial Permit Number: SW020036 +; Legal Description: NETTLETON ACRES #1 LT 1 Date Issued: Mar 18, 2002 Expiration Date: Mar 18, 2003 Parcel ID: 015-062-62 Design Engineer: 0003 S & S Engineering Site Address: Owner Name: John Faschan Lot Size: 53140 SO. FT. Owner Address: 7431 Solarset Cir. Total Bedrooms: 3 Permit Bedrooms: 3 Anchorage , AK 99507 - This permit is for the construction of. ❑✓ Disposal Field ❑� Septic Tank ❑ Holding Tank ❑ Privy ❑✓ Private Well ❑ Water Storage All construction must be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal Code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72 ) and Drinking Water Regulations (18AAC80 ). 3, The engineer must notify DSD at least 2 hours prior to each inspection. Provide notification by calling (907) 343-7904 (24 hours ). ( Not required for a Water Supply Permit only ). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must be either: A. Open and closed on the same day. B. Covered, sealed, and heated to prevent freezing. Received By: Date: 'Z - 20— e ` Issued By: Municipality of Anchorage • Development Services Department Building Safety Division On -Site Water and Wastewater Program 4700 South Bragaw St. P.O. Box 196650 Anchorage, AK 99519-6650 www.ci.anchorage.ak.us (907) 343-7904 ON-SITE SEWERIWELL PERMIT APPLICATION FOR A SINGLE FAMILY DWELLING Parcel I.D. U21-10;_7 Permit Number SW020036 Property owners) Sohn T ascitaYl Day phone L�Is-i33 Mailing address (1) `1431 Solarst� C1Rcic. Mailing address (2) "Q. MALVA Zip Code `1950} Legal description (Lot, Block & Sub'd.) 'Lot 1 . 4-ftII--} an ACRh.S Sob&w%Crr'_ # t Legal description (Section, Township & Range) r n �-,n Lot Size - -rv-� /Sq.Ft. Number of Bedrooms 3 11-10 / THIS APPLICVION IS FOR` 3 Sewer Only ❑ Well Only ❑ Sewer and Well Water Storage ❑ Sewer Upgrade ❑ THIS PROPERTY CONTAINS: Hot Tub ❑ Jacuzzi ❑ Swimming Pool ❑ Water Softening Unit ❑ Therapy Pool ❑ I certify that the above Information is correct. I further certify that this application is being made for a Single Family Dwelling and is in accordance with applicable Municipal Codes. (Signature of property owner or authorized agent) 17034 Eagle River Loop Road, NQ.;9V% Eagle River, Alaska 99577 Permit Fees: SSO - 14 Waiver Fees: Date of Payment: 3 / g / 0 .Z— Date of Payment: Receipt Number: 0 f 700.5" Receipt Number: (Rev. 12100) IIG n00Enr C. COWAN, P.E. :V9iA CML ENGINEERS (907)694-2979 FAX(907)694.1211 March 4, 2002 TCALnTATnNOTaTv APPROVALS NS MUNICIPALITY OF ANCHORAGE Development Services Department P.O. Box 196650 SEWERSWATEn Anchorage, AK. 99519 MNNE)NENSIONS REFERENCE: Lot 1, Nettleton Acres S/D #1 SEWER6WA,En - INSPECTION It is requested that you issue a permit to install well & septic system to serve the proposed three bedroom dwelling on the referenced property. ENGiNEETTWOSTUEMES A test hole was excavated and a percolation test was performed. The approximate location ANOTIEPORTS of the test hole is located on the attached site plan. At the time of excavation 3-19-92 water was not found. After seven days of ground water monitoring the test hole was found to be dry. Ow 6/$'Iyz. T„A4r4.t wqJ For"o 47- 1/ r -k: . or WELL INSPECTION FJJND AC -4-'l a N G/. rlq 2 . '. &FLOW,EST We do not anticipate any adverse effects on neighboring wells, septic systems, reserve areas or drainage patterns by the installation of the proposed septic system. The construction of this system will not prevent any future development on any of the adjacent SNEPIANS properties. If you require additional information, please contact us. ROAD OESTO, Sincerely, SOIL TEST /—&/z Robert C. Cowan, P.E. RCC/Jhm PERCOLATION TEST Enclosure smuauw a MECHANICAL 'INSPECTIONS Ce SITE WASTEWATER DISPOSALSYSTEM OESNiN 17034 NORTH EAGLE RNER LOOP • SURE 204 • EAGLE RIVER ALASKA 09577 / Z its O N0Nn / p CIO :7 p90 w N 0 gN 9^ jo. +> m mD0� r �z ^ c i 500 tr*t0 / Zy D0 �r D 0 0 m /n• i z ZZo -Im /O C] Q o � n 05 O r w^ cl r 4 "\9<,\\\+°� m Y v 0 -zV\,JP\�, PI l� SITE PLAN DESIGN 1" = 60' M C A rrA' F n 0. p=r 10 y0 ro kip as AAo pSVI \ \ / / =uug •� �O N <v Z / o �m m m Or _ _N_ O _ / Z its O N0Nn / p CIO :7 p90 w N 0 gN 9^ jo. +> m mD0� r �z ^ c i 500 tr*t0 / Zy D0 �r D 0 0 m /n• i z ZZo -Im /O C] Q o � n 05 O r w^ cl r 4 "\9<,\\\+°� m Y v 0 -zV\,JP\�, PI l� D Ili 10 111,\t4w' N VI A 0. 10 y0 as AAo �O 5C m � �O A m ;u = z Z�00 Z0 N <v = Ln �m m m Or _ _N_ O _ I Telecom & Elec Esmt O TJ NETTLETON Drive J dt 0 W o Lo Lo _ Ml =?: -. Ny �! �0 r 30 SanSewer Esmt J pyo _ rnav 37s X Onn y <In a,. Municipality of Anchorage DEPARTMENT OF HEALTH & HUMAN SERVICES 825 "L" Street, Anchorage, Alaska 99502-0650 SOILS LOG — PERCOLATION TEST PERFORMED FOR:—��/-t'�+�� 1-i��t' 1 DATE PE LEGAL DESCRIPTION: ��l 1 L �f.J I�CQ IoWnship, Range, Section: :Dcr� B¢ I l.i�� I SLOPE SITE SITE PLAN 1 'I t' 2 e. 3- 4 dl 5- 6- 7- 9- 101 69 10 , P 11 , 12 it. 0, N F1 6/S/qa. 13— V. f't'. 14 15 16 17 1s 19 20 PAY r/7/q7- L pfk j I&/15/92 WASGROUND WATER ENCOUNTERED) s IF YES, AT WHAT - L O DEPTH? p /1 6 hTi:aE Depthto Wrier A Monitoring? Orie: ®mmm W�NMFN �• PERCOLATION RATE (minuteLinch)PE�RC MOLE DIAMETER TEST RUN BETWEEN �T AND fje /� FT COMMENTS "'/"6'-122�-24- � PERFORMED BY: 17034 Eagle River Loop Road No.2W 1 v CERTIFY THAT THIS TEST WAS PERFORMED IN Eagle River, Alaska 99577 3'ZS�Z ACCORDANCE WITH ALLSTATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE. DATE: 72 -MB (Rev. 485) (,)01 a 9 10 77 MUNICIPALITY OF ANCHORA ry $110! �'�. : € 7 kA NR 2 2 2019 Development Services Department `�, / one: 907-343 •14 On-Site Water & Wastewater Section z x: 907-34 " •97 a68 Certificate of On-Site Systems Approval Parcel I.D. 015-062-62 Expiration Date: 1. GENERAL INFORMATION Complete legal description Nettleton Acres #1 Lot 1 Location (site address) 9410 Nettleton Drive, Anchorage, AK 99507 Current property owner(s) Raymond Schulte Day phone Mailing address 5624 Grandmother Hat Street, N. Las Vegas, NV 89081 Real estate agent Rhonda Richie Day phone 907-250-9098 2. TYPE OF DWELLING: H Single Family (w/wo ADU) n Duplex I I Multiple Dwellings (Single Family and/or Duplex) 3. NUMBER OF BEDROOMS: 6 4. TYPE OF WATER SUPPLY: TYPE OF WASTEWATER DISPOSAL: Private Well U Private Septic I x Water Storage I I Holding Tank I I Community Well I I Community I I Public Water System Li Public Sewer I I Waiver request for: Distance: Received by: Date: COSA to be released to the engineer. unless otherwise requested by the engineer. COSA Fee $ 550 Waiver Fee $ Date of Payment 31.9d1 Date of Payment Receipt Number OC9Pgt Receipt Number COSA# Gi ci`t 103.2 Waiver# 5. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based on procedures outlined in the Certificate of On-Site Systems Approval Guidelines for this application, shows that the on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is (are) in compliance with all applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation. I acknowledge that On-Site staff may visit the site to verify the information submitted. Name of Firm Forge Engineering Phone 907-522-7773 Address 1399 W. 34th Ave Suite 101, Anchorage AK 99503 Engineer's Printed Name Michael E. Anderson, P.E. Date 3/20/19 4740 {s f �zrI 6. DSD SIGNATURE ;"99th �� System #1 Approved forCbedrooms • t Tn.": MICHAEL E. ANDERSON L.,it • • No. CE-4381 .{ System #2 Approved for bedrooms •,),%. 3/20/19_,��`'� Disapproved ��otRos �••� Conditional approval for bedrooms, with the following stipulations: J� 3 ON-SITE WATER ANL WAS R PnGRAM R 4,t4'AT CFPoc' 'The: ,: (`� � / Original Certificate Date: 3 --7-S2- The Municipality of Anchorage Development Services Division (DSD) issues Certificates of On-Site Systems Approval (COSA) based only upon the representations given in paragraph 5 by an independent professional civil engineer registered in the State of Alaska. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. 7. ATTACHMENTS: COSA Checklist X Nitrate Advisory Septic System Advisory Arsenic Advisory Well Flow Advisory Other COSA Checklist blue sheet COSA Checklist Legal Description: Nettleton Acres#1 Lot 1Parcel ID: 015-062-62 If more than 1 septic system on lot: COSA Checklist# of Structure served by this system A. WELL DATA [' Well log is filed with Onsite (or attached) Well production at time of test 4.3 gpm Date drilled 3-9-03 Water storage tank volume N/A gallons Total depth 141 ft Well disinfected for coliform test? ❑ Yes 0 No Cased to 141 ft ❑■ Coliform bacteria is Negative ❑■ Sanitary seal is functioning correctly Nitrate,7 37 mg/L El Nitrate less than MRL (ND) 0 Wires are properly protected Arsenic ug/L ®Arsenic less than MRL(ND) Casing height(above ground) 16 in. Collected by Forge Engineering Date of flow test for COSA 3.13.19 Date of Sample 3/7/19 Static water level at beginning of test 94 ft. Comments B. TANK DATA C. LIFT STATION Age of tank(s) 13 years ❑ Required maintenance completed Tank type/material Advantex/Steel Age of lift station years Measured operating fluid level in septic tank Lift station material ■❑ Standpipes/foundation cleanout per record drawing Comments: Date of pumping Advantex maintenance 5/4/18 D. ABSORPTION FIELD DATA Shallow Trench Which system tested (date installed) 6/17"5 Adequacy test date 3113/19 ❑■ ALL standpipes present per record drawing Results ['Pass For 6 bedrooms Total measured depth from grade 6.5 ft(max) Fluid depth prior to test 7 in Measured depth to pipe invert from grade 3.5 ft (min) Water added 910 gal ❑ N/A—pressurized field New depth 13 in ❑■ Monitor tubes go to bottom of effective. If not, state Elapsed time 1440 min depth into effective Code-required soil cover over field Final fluid depth 0 in ■❑ System presoaked Absorption rate 910 gpd (Required if vacant for greater than 30 days prior to Any rejuvenation treatment(past 12 months) None date of test) 2058 If yes, enter date Gallons introduced gallons Comments/Deficiencies: COSA Checklist yellow sheet E. SEPARATION DISTANCES From Private Well on Lot to: (Please enter distances if less than required or if community well) Septic Tank/Lift Station on Lot> 100' Community Sewer Manhole/Cleanout> 100' 0✓ Yes if No ft 0 Yes if No ft Neighboring Tank > 100' El Yes if No ft Private Sewer/Septic Line >25' 0 Yes if No ft Absorption Field on Lot> 100' 0✓ Yes if No ft Holding Tank > 100' 0✓ Yes if No ft Neighboring Absorption Fields > 100' Animal Containment> 50' ElYes if No ft -Yes if No ft Manure/Animal Excreta Storage > 100' Community Sewer Main > 75' 9 Yes if No ft 2 Yes if No ft From Septic/Holding Tank on Lot to: (Please enter distances if less than required) Building Foundations > 10' 0 Yes if No ft Surface Water> 100' El Yes if No ft Property Line > 5' 0 Yes if No ft Wells on Adjacent Lots: Absorption Field > 5' 9 Yes if No ft Private Wells > 100' 9 Yes if No ft Water Main > 10' 9 Yes if No ft Community Wells > 200' 0 Yes if No ft Water Service Line > 10' 9 Yes if No ft If septic tank is under driveway comment below From Absorption Field on Lot to: (Please enter distances if less than required) Building Foundation > 10' 9 Yes if No ft If absorption field is under driveway comment below Property Line > 10' 0 Yes if No ft Wells on Adjacent Lots: Water Main > 10' 9 Yes if No ft Private Wells > 100' 9 Yes if No ft Water Service Line > 10' 9 Yes if No ft Community Wells > 200' 0 Yes if No ft Surface Water> 100' 0 Yes if No ft F. ENGINEER'S COMMENTS OF G. ENGINEER'S CERTIFICATION .••'' .. .... C��'�±�., • I certify that I have determined through field inspections and review a / �1,.. .\' •• of Municipal records that the above systems are in conformance with �! = 49th •`0 MOA COSA guidelines in effect on this date. r.. �, ... ....... .... .i • im �.HH..H..H......H..1tH11.H.H.fa■ .., r.-2°(.11; MICHAEL E. ANDERSON •;t w .. ..._(Q tw • ar v �J,•••. No. CE-4381 l( i •.♦f'(jp•"••• 3/20/19 ..s•' (c r COSA Checklist yellow sheet ., p pc�'�;.,,,,\``��♦ MUNICIPALITY OF ANCHORAGE DEVELOPMENT SERVICES DEPARTMENT • f 907 343 7904 • On-Site Water and Wastewater Section / Fax: 343-7997 www.muni.org/onsite Nitrate Advisory Certificate of On-Site Systems Approval # 0SC191082 Subdivision: Netttleton Accres #1, Lot: 1 A water sample revealed a nitrate concentration of 7.37 milligrams per liter (mg/L). The Environmental Protection Agency (EPA) has established a maximum contaminant level (MCL) of 10.0 mg/L for public drinking water systems. While private wells are not subject to this regulation, EPA standards are based on existing health information and can therefore be used to gauge the relative quality of water from private wells. Please see the attached "Nitrate Fact Sheet" for important information regarding nitrate. This advisory must be attached to all copies of the subject Certificate of On-Site Systems Approval. Mailing Address: P.O. Box 196650* Anchorage,Alaska 99519-6650 *www.muni.org • MUNICIPALITY OF ANCHORAGE ADVANCED WASTEWATER TREATMENT SYSTEM MAINTENANCE AND REPAIR AGREEMENT THIS MAINTENANCE AND REPAIR AGREEMENT,herein the"AGREEMENT" made and entered into as of this if Day of f.1arc,.i of 20 / ,by and between rr eh. S. Ana- . herein the"OWNER,"and the Municipality of Anchorage,herein the"MUNICIPALITY". in accordance with Anchorage Municipal Code (AMC) 15.65.365. In consideration of the mutual covenants contained herein, the parties to this Agreement agree as follows: 1. Advanced Wastewater Treatment Systems. The Municipality grants permission to the Owner to utilize and operate an Advanced Wastewater Treatment System(AWWTS), described as Advantex Treatment System located at(legal description) Nettleton Acres#1 Lot 1 2. Maintenance,Renairs and Alterations. (Owner is required to read,understand and initial each section) 47/1/- Throughout the term of this Agreement,the Owner shall enter into a service agreement with an AWWTS service and maintenance provider approved by the Municipality or the manufacturer's representative. The AWWTS shall be maintained in a satisfactory condition capable of performing as designed and producing treated septic effluent in accordance with the equipment's approval for operation in the Municipality. -bta It shall be the responsibility of the Owner during the term of this Agreement to pay for all repair(s), maintenance,adjustment(s), replacement costs,and inspection costs. This includes an annual maintenance fee(typically$400 to$600). \it• Owner agrees that only maintenance and repair personnel approved by the Municipality or the manufacturer's representative will inspect and make any necessary maintenance. repairs or permitted alterations to the system. Owner acknowledges that regular maintenance of an AWWTS reduces the potential failure of the system,which could include sewage backup and costly repairs or drainfield replacement. (rev. 05118/2018) Page 1 of 3 VI •Owner acknowledges that the Municipality may request records of maintenance and repairs from the manufacturer's representative or maintenance provider. hili?' Owner acknowledges that the fine for failing to maintain and repair an AWWTS may he assessed in accordance with AMC 14.60.030. 'lx--- Owner agrees to grant the Municipality reasonable access to test and inspect the AWs"l S. The Municipality will give at least 24-hour notice. Owner agrees that any sale or transfer of title of the property will not occur without a new Certificate of On-Site Systems Approval. 4c,p- Owner agrees that the AWWTS installation and maintenance requirements as provided by the AWWTS vendor/installer and approved by the Municipality are the governing guidelines for the construction,maintenance and repair of the Owner's AWWTS. - ' Owner agrees to maintain remote monitoring of the AWWTS as required by the AWWTS approval. 3. Term. The term of this Agreement shall begin on the date of approval by the Municipality to operate the installed system,or upon transfer of title,and shall continue while the AWWTS is operational or until title is transferred. 4. Nonwaiver. The failure of the Municipality at any time to enforce a provision of this Agreement shall in no way constitute a waiver of the provisions,nor in any way affect the validity of the Agreement or any part hereof,or the right of the Municipality thereafter to enforce every provision hereof. 5. Amendment. This Agreement shall only be amended by authorized representatives of the Owner and Municipality. Any attempt to amend this agreement by either an unauthorized representative or unauthorized means shall be void. 6. Jurisdiction: Choice of Law. Any civil action arising from this Agreement shall be brought in the Superior Court for the Third Judicial District of the State of Alaska at Anchorage. The laws of the State of Alaska shall govern the rights and obligations of the parties under this Agreement. 7. Severability. Any provisions of this Agreement decreed invalid by a court of competent jurisdiction shall not invalidate the remaining provisions of the Agreement. (rev. 05/18/2018) Page 2 of 3 Qw By: -fi (signature) Date: ga ,770/ 747LA.)2--- (print name) STATE OF ALASKA ) )ss. THIRD JUDICIAL DISTRICT ) The foregoin instrument was acknowledged before me this (5 day of , 20., by &iblo f, /U/ci 4704 r SPI fl'AC55 NOTARY PUBLIC FOR ALASKA My Commission expires: -(7-fat �- tire, Ili Giss Susie of Alaska C_____a/1/0613013**OS Ob`f 3.12022 MUNICIPALITY: By: (signature) Date: (print name) Title: (rev. 05/18/2018) Page 3 of 3 Parcel I.D. 015-062-62 1 Municipality of Anchorage On -Site Water and Wastewater Program (907) 343-7904 Certificate of On -Site Systems Approval 1:23, Expiration Date: /0 — >/ 15� GENERAL INFORMATION Complete legal description Nettleton Acres #1, Lot 1 Location (site address) 9410 Nettleton Drive Anchorage, AK 99507 Current Property owners) Kelley Brockway Day phone_ Mailing address 9410 Nettleton Drive Anchorage, AK 99507 Real Estate Agent Day phone 2. TYPE OF DWELLING: 0 Single Family (w/wo ADU) ❑ Duplex ❑ Multiple Dwellings (Single Family and/or Duplex) 3. NUMBER OF BEDROOMS: Five 4. TYPE OF WATER SUPPLY: TYPE OF WASTEWATER DISPOSAL: Individual Well Individual Individual Water Storage ❑ Holding Tank ❑ Community Class Well ❑ Community ❑ Public Water System ❑ Public Sewer ❑ WaiverNariancerequest for: Distance: Received by: Date: COSA to he released to the engineer, unless othemise requested by the engineer. COSA Fee $ 0�{o8-f ((af I o= �� Waiver Fee $ Date of Payment 1,2P30115- Receipt pP30117Receipt Number ObPL G COSA#1. SSC I� 1� o Date of Payment Receipt Number Waiver # 5. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based on procedures outlined in the Certificate of On -Site Systems Approval Guidelines for this application, shows that the on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation. Name of Firm Anderson Engineering Phone Address P.O. Box 240773 Anchorage, AK 99524 Engineer's Printed Name Michael E. Anderson, P.E. 522-7773 Date 6/30/2015 6. DSD SIGNATURE System #1 Approved for bedrooms System #2 Approved for bedrooms Disapproved Conditional approval for bedrooms, with the following By; Original Certificate Date:- — — The u ' p y chorage Development Services Division (DSD) issues Certificates of On -Site Systems Approval (COSA) based only upon the representations given in paragraph 5 by an independent professional civil engineer registered In the State of Alaska. The Municipality of Anchorage Is not responsible for errors or omissions In the professional engineer's work. 7. ATTACHMENTS: COSA Checklist X Nitrate Advisory Septic System Advisory Arsenic Advisory Well Flow Advisory Other COSA blue sheelf I- L e If more than 1 septic system is on the lot: COSA Checklist # Structure served by this system Certificate of On -Site Systems Approval Checklist Legal Description: Nettleton Acres No. 1, Lot 1 A. WELL DATA Well type Private If A, B, or C provide PWSID # Date completed 6-9-2003 Sanitary seal (Y/N) Y Total depth 141 ft Cased to 141 ft Date of test Static water level FROM WELL LOG 6-9-2003 77 ft. Well production 20 g.p.m. WATER SAMPLE RESULTS Parcel ID: 015-062-62 Well Log (Y/N) Y Wires properly protected (Y/N) Y Casing height (above ground) >18 in. AT INSPECTION 5/18/15 74 ft. 4.9 g.p.m. Coliform 0 colonies/100 mL Nitrate ND mg/L Arsenic ND ug/L Date of sample: 5/18/15 collected by: ArcTerra Consulting B. SEPTIC/HOLDING TANK DATA Tank Type/Material Septic/Advantex Date installed 6/20/2006 Tank size 2,500 gal. Number of Compartments 2 Cleanouts (YIN) Y Foundation cleanout (Y/N) Y Depression over tank (Y/N) N High water alarm (Y/N) Y Date of pumping Pumper Advantex Maintenance - Anchorage Tank C. ABSORPTION FIELD DATA Date installed 6/18/15 Soil rating (g.p.d./if orit2/bdrm) 2 GPD/SF System type 5' Wide Length 53 ft. Width 5 ft. Gravel below pipe 3 ft. Total depth 8.5 ft. Eff. absorption area 913 ftp Monitoring tube Y Depression over field N New Const. Date of adequacy test Results (Pass/Fall) For _bedrooms Fluid depth in absorption field before test in. Water added gal. New depth in. Elapsed Time; min. Final fluid depth in. Absorption rate >= g.p.d. Any rejuvenation treatment (past 12 mo.) (YIN & type) N If yes, give date D. LIFT STATION Date installed Size in gallons Manhole/Access (YIN) "Pump on" level at in. "Pump off' level at in. High water alarm level at In. Datum Cycles tested Meets alarm & circuit requirements? E. SEPARATION DISTANCES -AWWU Water System WELL ON LOT TO: Septic tank/lift station on lot 00 On adjacent lots >100 Absorption field on lot >100 On adjacent lots >100' Public sewer main >75' Public sewer manhole/cleanout >100' Sewer /septic service line >25 Holding tank >75 Animal containment areas >50 Manure/animal excrete storage areas >100' SEPTIC/HOLDING TANK ON LOT TO: Building foundation >5' Property line >5' Water main >10' Water service line >10 Wells on adjacent lots >100' ABSORPTION FIELD ON LOT TO: Property line >10' Building foundation >10, Water Service line >10, Surface water >100 Curtain drain None Noted Wells on adjacent lots >100' Absorption field >5' Surface water >100' Water main N/A Driveway, parking/vehicle storage >10, F. COMMENTS Flow Diverter Valve in Place. Two Absorption Trenches are Connected for Future Use as Required. G. ENGINEER'S CERTIFICATION I certify that t have determined through field inspections and review of Municipal records that the above systems are in conformance with MOA COSA guidelines in effect on this date. Engineer's Printed Name Michael E. Anderson, P.E. Date 6/30/2015 COSA brown sheet 10-10-12.dac rA 1p, '. MICHAEL E. ANDERSON `� • GE - 4381 1 M PLOT PLAN AS BUILT X SCALE 1" a 60' GRID SW 2439 Project No. 15-185/A1 Lang & Associates, Inc. 11500 Daryl Avenue, Anchorage, Alaska 99515-3049 (907) 522-6476 Phone Registered Land Surveyors (907) 522-4625 Fax ,=4�� kenOlongsurvey.com / JonathanOlongsurvey.com o`f,..••••••. I hereby certify that i have surveyed the following described property: LOT 1, NETTLETON ACRES UNIT 1 (PLAT 92-114) 491}-J� Anchorage Recording District, Alaska, and that the Improvements situated thereon aro :....... • ............ within the property lines and do not encroach onto the property adjacent thereto, that no improvements on the property lying adjacent thereto encroach on the surveyed promises and that there are no roadways, transmission lines or other visible 4.. KQJNETN G. LAN.. easements on sold property except as indicated hereon. (.�� ,N Dated this the 25" Day of 2x 15 , at Anchorage, Alaska �� 1 ....5?0 ... • It Is the responsibility of the owner to determine the existence of any easements, �pO�SSIONAO� covenants, or restrictions which do not appear on the recorded subdivision plot.