HomeMy WebLinkAboutDEL'S LT 4Del's
Lot 4
#015-492-04
Municipality of Anchorage Page I of
DEPARTMENT OF HEALTH AND HUMAN SERVICES
ENVIRONMENTAL SERVICES DIVISION
P.O. Box 196650 • Anchorage, Alaska 99519-6650 is Telephone: 343-4744
On -Site Wastewater Disposal System and/or Well Inspection Report
Permit Number: .5u/9700('Z PID Number: 016'402 oy
Name: SFC J7 en l<¢rm
Wastewater System: ® New 54 Upgrade
Addfess:62oo a Jrz"'hoe, hnch 99516
ABSORPTION FIELD
Phone: y
2 % Z — 2 z 2
No. of S rooms:
Il Deep Trench ❑Shallow Trench ❑Bed ❑Mound ❑Other
LEGAL DESCRIPTION
Soil Retina: 0- 49
Total Depth from original Grade:
y
GPD/Sq Ft
Lot: u Block— Subdivision:
Depth to pitta bottom from original grade:
Gravel depth beneath pipe
_7 I)e 1 S
2.3 Ft
S / Ft.
Township: --range
Township:
Range:
Section:
Fill added above Original grade:
Gravel length:
771
/. o t Ft
Ft.
WELL: F�7ST O New ❑ Upgrade
p9
aaN.:w(
Gravel 6 W
Numberof li es:
1 (en�
Disunce Deraeen linea:
2.0 Ft.
Ft.
Classification (Private. A,B.C):
Total Depth:
Cased To:
Total absorption area:
PipemateriaC f erjc`
Ft.
I Ft.
S SO Ft.
Q -SO 3'r
Driller.
Date Drilled:
Static Water Level:
Installer: a
Car'!s CAMoalrYn
Date Installed:
6/I! /97
Ft.
yield:Pump
set at:
Cuing Height Above Ground:
TANK
GPM
Ft.
Ft.
SEPARATION
DISTANCES
CK Septic 0Holding ❑S.T.E.P.
To
Septic
AMorpaon
Lin
Holdep
PubllWVdvals
Manufacturer.
Capacity In gallons:
From
Tana
Field
station
Tank
aswwLines
AAChorQ e Tank
J.Yoo
Well
16s'
l6r
>zs'
Material: SfY e l
!z
Number of Compartments:
2
Surface
—
—
—
LIFT STATION •.
NA
Water
Water
>Inc'
>IGU'
LotSize
In gallons:
Manufacturer:
Line
36'.
1
—
—
—
FoundationI
UG'
I Zo'
_
—
r
'Pump on" level at:
"Pump off' level at:
Migh water alarm at:
Curtain
Pump Make d Model
Electrical Inspections performed by:
Drain
—
—
—
—
Remarks: -rrcnch ,nre ImA-a W. 2° rr ek
BENCH MARK
ual Tank d -a 1fcria [ lint itoAe-e
Location and Description:
Top of Susie Cate
ria/ COW' 3' pL&V rnra.efMAO /, ee�hs, .
of 1qW pe-operfy propercornu
Assumed Elevation:
od- etuc./aa le lent T-vT a t ".,A,cA
fUO.OFt
ser t/ uno/r o[rts.tcs✓�e snr«/u!-etoC sir. y" ry l � M
ENGlfdU*MftlkL
"'� '' r
.tai♦ �',�• �'i: t � ZT
p• nu! t Ac %rak ti f a6tnclone
FtafioP T-tch Sr.e
Inspections performed by: Dates:1st G/9 / 9 7
rw:
la........' :...... .....:e:
s;
2nd Gllo/9�
'rr . .. ..:.fin•:•
P. M:
�TH_a.:cg:
?
Department of Health ari Human Services approval
�;
� fir....
Reviewed and approved by: Date: G— /947
`fi�VLt
72-017 (1A1) MOA 25
Permit No. SW 970012
Parcel I.D. No. 01549204
T.B.M.7 EAST 112TH AVENUE
r,. 1. 33
Page 2 of 3
r -
GARAGE
LOT 3
WELL
do- .
A AV
\\1 e* 49
-' 49 n
I•......••.••. •••.••••.•
BUILDING �, �• THEOOORE F. MOORE
CE -3589 ,
LOT 4, DEL'S S/D
�R 10o WELL SEPTIC SYSTEM UPGRADE
AS -BUILT INSPECTION REPORT
NOTE: THIS DRAWING IS BASED ON FLATTOP TECHNICAL SVCS. SCALE: I"= 30'- 0"
AN AS -BUILT PROPERTY SURVEY 14530 ECHO ST. DRAWN BY: T.F.M.
PREPARED BY JEFFERY GASTALDI ANCHORAGE, AK 99516 JUNE, 1997
DATED 6/13197
.
I
J.
LOT 4
p
p
NEW 97' LONG
p
SOIL ABS. TRENCH
p
W.5.1'SEWERGVL.
—
9
BELOW DIST. PIPE
C.O. p.
/
.®
H.
/
p
/
SWING TIES:
FROM:
BLDG. COR. "A"
COR. "C"
—DBL. C.O. "G"
TO:
.F.
/
C.O. "D
67'
63'
NEW 1500 GAL.
S.T. C.O. "E"
111.5'
85'
.E.
SEPTIC TANK
S.T. C.O. "F"
120.5'
95'
DBL. C.O. "G"
123'
98'
TR. C.O. "H"
127'
107'
hvTR.
M.T. "1"
169'
166'
TR. C.O. "J"
159'
171'
I
R 100
r -
GARAGE
LOT 3
WELL
do- .
A AV
\\1 e* 49
-' 49 n
I•......••.••. •••.••••.•
BUILDING �, �• THEOOORE F. MOORE
CE -3589 ,
LOT 4, DEL'S S/D
�R 10o WELL SEPTIC SYSTEM UPGRADE
AS -BUILT INSPECTION REPORT
NOTE: THIS DRAWING IS BASED ON FLATTOP TECHNICAL SVCS. SCALE: I"= 30'- 0"
AN AS -BUILT PROPERTY SURVEY 14530 ECHO ST. DRAWN BY: T.F.M.
PREPARED BY JEFFERY GASTALDI ANCHORAGE, AK 99516 JUNE, 1997
DATED 6/13197
PERMIT NO: SW970012
PID NO: 01549204
RIGID INS.
1500 GAL. SEPTIC TANK
INV.
101.3'
2' SOIL COVER
RIGID INS.
PAGE 3OF3
101.0' INV.
100.1'
W -• os
49 m
..................
THEODORE F. MOORE
0_ CE -3589
!ofesslo -4
TRENCH ELEV. 95.0' INV.
100.1'
T.H. #1
H2O@
91.0'
6/9/97
LOT 4 DEUS SID
SEPTIC SYSTEM UPGRADE
AS -BUILT CROSS-SECTION
FLATTOP TECIINICAL SERVICES
NOT TO SCALE
97' LONG SOIL ABS. TR.
DRAWN BY TFM
101.0' INV.
100.1'
W -• os
49 m
..................
THEODORE F. MOORE
0_ CE -3589
!ofesslo -4
TRENCH ELEV. 95.0' INV.
100.1'
T.H. #1
H2O@
91.0'
6/9/97
LOT 4 DEUS SID
SEPTIC SYSTEM UPGRADE
AS -BUILT CROSS-SECTION
FLATTOP TECIINICAL SERVICES
NOT TO SCALE
14530 ECHO STREET
DRAWN BY TFM
ANCHORAGE.ALASKA99516
JUNE, 1997
,TJN-06-1997 15:04
0
FLATTOP TECH. SVCS.
9073451355 P.01
ClYM & ENYMONMENTAL ENG]NEERING • ENERGY
THEODORE F. MOORE, P.E.
PH: (907) 345-1355
FAX COVER LEITER
Date: T-C^e 6 199 7
To: Dao) Ra A
D N !fJ
FAX ;9: 3 V3 _ y756-
• ANALYSIS
14530 ECHO ST.
AINCHORAGE, ALASKA 99516
RECEIVED
JUN 9 1991
Municipality of Ancnw ude
Dept. Health & Human Services
Subject: L.of `1 P --Ir S/D - Dvr•n m-C./,1-.ca/io'.,
From: �-
Total : of Pages (incl. cover letter) 2
Fv dow - or groa�aCcuc■�C� /AG n. %� rr� �i /w� % Sk*�f o�
dont k'uc.Ae,c.a<of ctn .sgexPCACai SC'g+lo+o/
IG✓G/ at Il.S r "(" ey ,,..+d five/ x T, K, ft-/. Acco- PO o7 y�
S Orn K✓c[in/ J�AC %r t✓^c�, )n fhb
bof/�rn o f / 7^e f/q r.✓"</ of 7.S d clew �.w^iC
r Or C I v @ 2-S" � .- S ' e / 'f J'«
/yC e c ii v h 'u < 7on ro.v
7 G !'.r o.�e.� 70 9f
e GlRf'n o� 9.7 �J C7, df GooV-�C/i✓C CcS tv��7 �snn RiL 4.
me
.Q
O'MALLEY
SCHOOL
TRACT
L5, 84, SO. LAKEWOOD HILLS #1
Y W
ol 0
�
Q:
---
C.O.
CONSTRUCT 94' LONG _
SOIL ABS. TRENCH W.
V GRAVEL BELOW PIPE
BOTTOM OF TRENCH
AT 7.5' BELOW GROUND
LEVEL IN VICINITY OF
TEST HOLE #1. TEE
FEED LINE INTO PERF.
PIPE AT A POINT NO
MORE THAN 50 FEET
FROM ANY END OF TR.
INSULATE AS NEEDED
WHERE <T SOIL COVER
ABANDON
SEPTIC
TANK
FORSYTHE
PARK
45'
EAST 112th AVENUE
iL T.H.
O. e• �
�. M.T.
T.H.
#1 1 "
4 DBL.
C.O. C.O.
�
DRIVE 'oo
INSTALL
NEW 1500 GAL.
C.O. , SEPTIC TANK
I ULATE
GAR.
�•R 10(y
LOT 4
DEUS S/D
=R 100' FROM WELL
-------- r
NEW 4" DIA
ASTM D-3034
EXISTING
HOUSE
WELL
o
SEPTIC
' o SYSTEM
N
HOUSE
I
—WELL
LOT 3
DEL'S S/D
,
F
p.
co,.• •:�
././...........49
•//•0�•••�•••••..•
I. THEODORE F. MOORE : k
(p�� '•• CE -3589 .�Q
Ar
/4AV
� �ofeaslof-•
' ---- ---------------------- ---------- -------------
IL
20 0 20 40 60 80 100
ewn
LOT 3, SHADOWBROOK S/D FEET
SEPTIC SYSTEM
GREATER THAN
100 FEET FROM
LOT 4
SHADOWBROOK S/D
5l r
LATTT0P TEGI
CIVM& ENVIRONMENTAL ENGINEERLVG - ENERGY CONSERVATION & ANALYSIS
THEODORE F. MOORE, P.E. 14530 ECHO ST.
PH: (907) 345-1355 April 29, 1997 ANCHORAGE, ALASKA 99516
M.O.A. DIMS - Attn: Dan Roth
P.O. Box 19-6650
Anchorage, AK 99519
Dear Mr. Roth:
As we discussed over the phone, the purpose of this letter is to request a modification of permit #
SW970012 issued on 1/30/97 for Lot 4, Del's S/D to increase the number of bedrooms from 3 to 5. A
lot line waiver is also being requested allowing the soil absorption trench to be constructed within I foot
of the north property line. Revised design drawings and specifications are enclosed.
The general location and cross-section of the proposed trench will remain unchanged, however the
length will be increased from 36 to 60 feet.
Since the lot line involved in the requested waiver fronts on a street, granting the waiver will have no
impact on the ability of adjoining property owners to construct future wastewater disposal systems.
Please give me a call at 345-1355 if you have any questions on this submittal.
Sincerely,
Ted Moore, P.E.
NIGAL
SERVICES.a
CIVM& ENVIRONMENTAL ENGINEERLVG - ENERGY CONSERVATION & ANALYSIS
THEODORE F. MOORE, P.E. 14530 ECHO ST.
PH: (907) 345-1355 April 29, 1997 ANCHORAGE, ALASKA 99516
M.O.A. DIMS - Attn: Dan Roth
P.O. Box 19-6650
Anchorage, AK 99519
Dear Mr. Roth:
As we discussed over the phone, the purpose of this letter is to request a modification of permit #
SW970012 issued on 1/30/97 for Lot 4, Del's S/D to increase the number of bedrooms from 3 to 5. A
lot line waiver is also being requested allowing the soil absorption trench to be constructed within I foot
of the north property line. Revised design drawings and specifications are enclosed.
The general location and cross-section of the proposed trench will remain unchanged, however the
length will be increased from 36 to 60 feet.
Since the lot line involved in the requested waiver fronts on a street, granting the waiver will have no
impact on the ability of adjoining property owners to construct future wastewater disposal systems.
Please give me a call at 345-1355 if you have any questions on this submittal.
Sincerely,
Ted Moore, P.E.
r^ n
Municipality, of Anchorage
Department of Health and Human Services
825 "L" Street
Rick Mystrom, P.O. Box 196650 Anchorage, Alaska 99519-6650
Mayor
343-4744
April 30, 1997
Ted Moore, P.E.
Flattop Technical Services
14530 Echo Street
Anchorage, Alaska 99516
Subject: Waiver Request for Lot 4 Del's Subdivision
Waiver Request OWR970012 , PID 0015-492-04
Dear Mr. Moore:
Your request for a waiver of the required 10 foot separation
between an on-site wastewater disposal system and a lot line has
been approved. The waived distance is within one (1) foot of the north
property line.
This approval applies to the existing on-site wastewater disposal
system lot line separation only. Any future upgrade to the on-site
wastewater disposal system will require all separations be met or
another approval from this department.
If there any further questions or concerns regarding this waiver,
please call our office at 343-4744.
Sincerely,
Daniel J. Roth
Civil Engineer
On-site Services
ljw 07
MUNICIPALITY OF ANCHORAGE
Department of Health and Human Services
On-site Services Section
Waiver Review Worksheet
WR# 970017 PID# 015-492-04
Date Received: 04/29/97
HA# Permit #SW970012
Legal Description: Lot 4 Del's Subdivision
Engineer: Flattop Technical Services/Ted Moore
Applicant: Steven Keim
Waiver Requested: Lot line waiver:allowing soil absorption trench to be constructed
within 1 foot of the north property line
Criteria: 1. Geology: Points:
A. Water Table
B. Soil Sorption
C. Permeability
D. Water Table Gradient
E. Horizontal Separation
TOTAL:
2. Special Conditions:
3. Other:
Waiver is Granted: k Waiver is NOT Granted:
List Conditions or Reasons for above: SEE t7w6/Nfe6 o9mge"ArO L E7reR
01Z yt45r7F/Ci9Yi0A1
Date: 4 - 30-27 By: 19AN
Name of Reviewer
Rec #: 02863 Amount: $ 115.00 Date Paid: 04/29/97
TEGHNIGAL SER�'�ICES`__
CIVIL & ENVIRONMENTAL ENGINEERING • ENERGY CONSERVATION S ANALYSIS
TitEODORF. F. MOORE, P.E. 14530 ECHO ST.
Pit: (907) 345.1355 January 29, 1997 ANCHORAGE, ALASKA 99516
M.O.A. DHHS
P.O. Box 19-6650
Anchorage, AK 99519
Dear Sirs:
The purpose of this letter is to provide the required design narrative in support of our application for a
permit to upgrade the wastewater disposal facilities serving the existing 3 bedroom residence on Lot 4 of
Del's S/D, located at 6200 East 112th Avenue. A recent adequacy test showed the present system to be
operating in a surcharged condition. Soils logs, pert test results, a site plan, design drawings and
specifications are enclosed for your review. Due to a misunderstanding between the Realtor and lender, it
has only now become apparent that a conditional HAA certificate is essential for the sale of the property to
close as it is very important for it to do this week. Accordingly; your utmost cooperation is requested in
expediting the requested upgrade permit and conditional HAA certificate.
The proposed system will be constructed in the vicinity of test hole # 1. As can be seen from the soil
log, the native material between 2.5' and 16' is a silty gravely sand with a measured pert rate of 8 minutes
per inch. Using the soil application rate of 0.8 gpd/sq. ft. specified in the wastewater ordinance, this 3
bedroom residence requires a total absorption area of (3 x 150)/0.8 = 563 square feet. The proposed 36
foot long trench design with 8 feet of sewer gravel beneath the distribution pipe has a total absorption area
of 576 square feet.
The topography of the lot in the area of the proposed construction is generally level.
The proposed project will have no significant impact on present or future water supply and wastewater
disposal systems serving adjacent properties, nor will it have any significant impact on reserved space -
surface and subsurface, or on drainage.
Please give me a call at 345-1355 if you have any questions on this submittal.
Sincerely,
J—C+c -
Ted Moore, P.E.
O'MALLEY
SCHOOL
TRACT
r
ABANDON
SEPTIC
TANK
FORSYTHE
PARK
L5, B4, SO. LAKEWOOD HILLS #1 1
of o --___-_--r 0'
1-=R 109 WELL
0I -
L� — — — — EAST 112th AVENUE
;TRACT 60' LONG
ABS. TRENCH
18' GVL. BELOW PIP 15'
O. L T.H. 0 0
,I
1, &�� _ _ _ _ _ _ _ SEPTIC
N o SYSTEM
c M.T._T.H.
#1 1 e
DBL.
C.O. C.O.'
I A
I HOUSE
DRIVE ° �$,
INSTALL
°v NEW 1500 GAL.
C.O. , SEPTIC TANK
IN ULATE
LIN \
UN ER NEW 4" DIA --WELL
DR E ASTM D-3034
_ LOT 3
DEUS S/D
EXISTING
GAR. HOUSE
R IOU AV
�- 0
LOT4 WELL .........................
DEL'SSID 0,.....yV�.o
1 i THEODORE F. MOORE i
� '.• CE -3589 •� Ar
,11�wAV
Aofe3S10T0
L
"20 0 20 40 60 -80 100
LOT3,SHADOWBROOKS/D FEET
SEPTIC SYSTEM LOT 4, DEL'S SID
GREATER THAN SEPTIC SYSTEM UPGRADE
SITE PLAN
100 FEET FROM
I
WELL FLATTOP TECI MCAL SERVICES 1 INCH = 50 FEET
LOT4 14530 ECHO STREET DRAWN BYTFM
SHADOWBROOKS/D ANCIIORAGE,ALASKA 99516 REV. APRIL, 1997
I .I�Te-. TIJIC IC \I/1T A CI ID\/GVG11 OI 11T
-------------
-- ------------
;; C.O.
M.T.
CONSTRUCT 60' SOIL ABS. LONG TRENCH
WITH 8' GRAVEL BELOW DISTRIBUTION PIPE
4" DIA F-810 PERF PIPE
PLAN VIEW
DIA D-3034 PIPE SCALE: 1" =10' - 0"
N u
u
1
DBL C.O.
INSTALL
NEW 1500 GALLON
SEPTC TANK
----4" DIA D -D034 WASTE LINE FROM HOUSE
MONITOR TUBE
CLEANOUT ��P•'. •��
MOUND COVER MATERIAL 17' r y,
000
�.ii.."...Y:lr%
p :� THEODORE F. MOORE �;
CE -3589. 0: �<�
ORIGINAL GROUND ��,e^ ..0..�' e
Professlot`s��.. `--.
FILTER FABRIC 1�%\���� •
4" DIA F-810 PERF. DIST. PIPE
i.
1/7'-212" SEWER GRAVEL
BOTTOM OF EXCAVATION
SECTION "A - All
SCALE: I" = 5'- 0"
N
cd
m
DBL C.O.
INSTALL
NEW 1500 GALLON
SEPTC TANK
----4" DIA D -D034 WASTE LINE FROM HOUSE
MONITOR TUBE
CLEANOUT ��P•'. •��
MOUND COVER MATERIAL 17' r y,
000
�.ii.."...Y:lr%
p :� THEODORE F. MOORE �;
CE -3589. 0: �<�
ORIGINAL GROUND ��,e^ ..0..�' e
Professlot`s��.. `--.
FILTER FABRIC 1�%\���� •
4" DIA F-810 PERF. DIST. PIPE
i.
1/7'-212" SEWER GRAVEL
BOTTOM OF EXCAVATION
SECTION "A - All
SCALE: I" = 5'- 0"
Flattop Technical Services
14530 Echo Street, Anchorage, AK 99516
Phone (907) 345.1355
Lot 4, Del's S/D
6200 East 112"Avenue
Wastewater disposal system installation
Revised Specifications - 4/97
1.0 General:
1.1 The scope of the project consists of abandonment of an existing 1000 gallon septic tank and
installation of a new 1500 gallon septic tank followed by 60 lineal feet of soil absorption trench
containing a total of 8.5 feet of sewer gravel.
1.2 Construction shall be as depicted on the approved site plan and design drawings. Minor
deviations from these drawings may be allowed or required by the engineer conducting the inspections.
All construction procedures and material specifications shall conform with Municipal and State
requirements. All separation distances shall be in conformance with Municipal requirements, unless
specifically waived.
1.3 The contractor shall be responsible to obtain any necessary utility locates, and to work around
any buried utilities.
1.4 The contractor shall provide adequate cover material and rough grading over all system
components to ensure that proper drainage is achieved after settlement and that there are no residual
depressions. Insofar as possible the contractor shall minimize damage to trees and existing lawn areas.
1.5 Unless specifically agreed otherwise, the homeowner shall be responsible for finish grading after
the soil is compacted, as well as placement of topsoil and reseeding all areas disturbed by the
construction.
1.6 The property owner shall be responsible for arranging a survey delineating the location of the
north property line in the vicinity of the proposed construction.
2.0 Septic Tank:
2.1 The existing septic tank must be properly abandoned by thoroughly pumping, removing the top
and backfilling with soil.
2.2 The new 1500 gallon, 2 compartment septic tank shall be Municipally approved and shall be set
level on undisturbed soil. Each compartment shall be equipped with a watertight manhole cover and a 4"
cleanout. If the tank is buried less than 4 feet, it shall be insulated with 2 inches of approved burial type,
rigid insulation.
2.3 All pipe connections to the tank shall be equipped with waterproof mechanical couplings. The
waste line from the residence to the septic tank shall have a minimum slope of 1/4"' per foot, and the
waste line between the tank and the soil absorption system shall have a minimum slope of 1/8" per foot.
A cleanout shall be installed within 5 feet of the building foundation, and a double cleanout shall be
installed within 5 feet downstream of the septic tank.
2.4 The portion of the waste line leading from the garage to the new septic tank which passes
underneath the paved driveway shall be insulated with 4 inches of rigid foam insulation, 2 feet wide.
3.0 Soil absorption system:
3.1 The soil absorption system shall be constructed by excavating a 60 foot long trench to a total
depth of 11 feet below original ground level in the vicinity of test hole # 1.
3.2 The bottom of the excavation shall be level. Any compacted or smeared surfaces shall be raked
to allow proper infiltration. Sand for leveling or serving as filter material shall comply with Municipal
specifications.
3.3 A total of 8.5 feet of approved sewer gravel shall be placed in the bottom of the excavation with
the perforated distribution pipes laid level such that the pipe inverts are no less than 8.0 feet above the
bottom of the sewer gravel. Sewer gravel shall be 0.5" - 2.5" screened gravel, with less than 3% passing
the 9200 sieve.
3.4 Monitor tubes and cleanout pipes shall be of 4" diameter and installed in the locations shown on
the design drawings. The portion of the monitor tube extending through the sewer gravel shall be
perforated.
3.5 Approved filter fabric shall be placed over the entire top surface of the sewer gravel. A minimum
of 2 feet of soil cover is to be placed over the filter fabric. If the soil cover thickness is less than 3 feet,
two inches of rigid, burial type insulation is to be placed over the entire top surface of the gravel, in
addition to the filter fabric.
3.6 The top surface of the cover material shall be raised a minimum of 12 inches higher than the
surrounding terrain to allow for subsequent settlement, and shall be graded to smooth contours. Fill
slopes shall be no steeper than 3:1.
3.7 Unless specifically agreed otherwise the homeowner shall be responsible for arranging to have
the site finish graded after the backfill material has stabilized, and for placement of adequate topsoil and
seed to promote rapid revegetation of all areas disturbed by the construction.
4.0 Inspections:
4.1 A minimum of 4 engineering inspections will be required during the course of the project: (I)
initial stakeout with the contractor to establish the location of the system and to discuss the plans,
specifications and construction procedures, (2) after the native material has been excavated to expose the
infiltrative surface to ensure that it is level and at the right elevation, and conforms with the soil test
information, (3) after the sewer gravel is in place and the distribution pipes have been laid and connected
up to the septic tank, but prior to placement of insulation or filter fabric, and (4) after rough backfill and
grading is complete. The septic tank requires one inspection after it is set level and the piping connected,
but prior to backfill. This inspection may be incorporated with any of the above inspections.
4.2 The installer shall coordinate the timing of the inspections with the engineer sufficiently far in
advance to ensure the availability of the engineer.
PAGE 1 OF 1 q
MUNICIPALITY OF ANCHORAGE
DEPARTMENT OF HEALTH AND HUMAN SERVICES
P.O. BOX 196650, 825 "L" STREET, ROOM 502
ANCHORAGE, ALASKA 99519-6650
ON-SITE WASTEWATER DISPOSAL SYSTEM (UPGRADE) PERMIT
PERMIT NUMBER:SW970012
DESIGN ENGINEER:FLATTOP TECHNICAL SERVICES
OWNER NAME:BARRACK MARTIN J & PATRICIA N
OWNER ADDRESS:6200 E 112TH AVE
ANCHORAGE, ALASKA 99516
PARCEL ID:01549204
LEGAL DESCRIPTION:
DEL'S LT 4
LOT SIZE: 49404 (SQ. FT.)
NUMBER OF BEDROOMS: THIS PERMIT:�j /
THIS PERMIT IS FOR THE CONSTRUCTION OF:
DISPOSAL FIELD /SEPTIC TANK SYSTEM
ALL CONSTRUCTION MUST BE IN ACCORDANCE WITH:
DATE ISSUED: 1/30/97
EXPIRATION DATE: 1/30/98
1. THE ATTACHED APPROVED DESIGN.
2. ALL REQUIREMENTS SPECIFIED IN ANCHORAGE MUNICIPAL CODE CHAPTERS
15.55 AND 15.65 AND THE STATE OF ALASKA WASTEWATER DISPOSAL
REGULATIONS (18AAC72) AND DRINKING WATER REGULATIONS (18AAC80).
3. THE ENGINEER MUST NOTIFY DHHS AT LEAST 2 HOURS
PRIOR TO EACH INSPECTION. PROVIDE NOTIFICATION BY
CALLING 343-4744 ( 24 HOURS ) . (NOT REQUIRED FOR WELL ONLY PERMIT)
4. FROM OCTOBER 15 TO APRIL 15 A SUBSURFACE SOIL
ABSORPTION SYSTEM UNDER CONSTRUCTION DURING FREEZING
WEATHER MUST BE EITHER:
A. OPENED AND CLOSED ON THE SAME DAY
B. COVERED, SEALED AND HEATED TO PREVENT FREEZING
5. THE FOLLOWING SPECIAL PROVISIONS.
SPECIAL PROVISIONS:
RECEIVED BY:
ISSUED BY:
DATE: lhwoll
09 DATE: 1-30-477-
I
4`30-L77 SEE EN6l*veEJ6 4)r�4"F0 AKeuoao Pesl6.v phreo ¢-2f-f7
S- Y- Q% SAF F,161-vPZ-kS A%/i9CHr-Q ApjrvOFp D£S/GA �EsucT�/vG FPo,y
GIPUua,o w�i �� <'u/y.ri,vG GtP.
TEST HOLE# 1
FLATTOP TECHNICAL SERVICES
14530 ECHO ST.
ANCHORAGE, ALASKA 99516
SOILS LOG - PERCOLATION TEST
LEGAL DESCRIPTION: Lot 4. Del's S/D
DATE PERFORMED: December 27, 1996
PERFORMED FOR: Patty Barrack
DEPTH SLOPE
(feet) _ "_' _ Pl. 1—TT-I
SM Silty sandy loam
SP/SM Silty gravelly sand
Variable with lenses of SP
Dry, dense, many cobbles
NIL Gravelly silt
Dense, caked, damp
B il.
O
Depth to GroundwaterDate
No Groundwater 1
Monitor tube 1 7
w
a
O
N
r....................f ,aa.
TWOOCAS F. MCOke j
ICE -'25'; :f '
•�4�'s'.�'•... .. ••�r:J
SITE PLAN
EAST 112th AVE.
T.N. 61 T.M.
or .t
4 c
T p V
O`
EXIST
SEPTIC tia3e
SEPTIC
eqq, HOUSE
WELL
:.....:.....:.....:.....:..........:..........:10%
Date Reading
Clock
Time'
Net Time
(minutes)
Percometer
Reading
Net Dro
(Inches
1
7 In
Add water
23-271/2
Start
--IL57
4
NI12,02
5
22112
314
Add water
12:02:45
231/4
N2
12:07:45
11 I _•
12:08
237/16
N3
12:13
5
221'16
4
Add water
12:13:30
23 !/-1'6-
2: 8:30
5
2211/164
I I PERCOLATION RATE 8 (minutesAnch) PERC HOLE DIAMETER 6
TESTRUNBETWEEN 6.5 FTAND 70 FT
COMMENTS: The soil absomtion system should be constructed in the vicinity of this test hole Size trench on basis of 0.8 Eod/sn ft
PERFORMED BY FLATTOP TECHNICAL SERVICES. I CERTIFY THAT THIS TEST WAS PERFORMED IN
ACCORDANCE WITH ALLSTATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE. DATE:-44�
1/29/47
FLATTOP TECHNICAL SERVICES
14530 ECHO ST.
ANCHORAGE, ALASKA 99516
TEST HOLE # 1 SOILS LOG - PERCOLATION TEST
LEGAL DESCRIPTION: Lot 4 Del's S/D
DATE PERFORMED: December 27, 1996
PERFORMED FOR: Patty Barrack
ncmT SLOPE
(feei) 5� PL
SM Silty sandy loam
SP/SMI Silty gravelly sand
Variable with lenses of SP
Dry, dense, many cobbles
ML Gravelly silt
Dense, caked, damp
B.H.
Depth to Groundwater Date
No Groundwater
Monitor lube d 1 7
W
n.
O
N
:>..... '
SITE PLAN
Date Readin 9
EAST 112th AVE.
Net Time
(minutes)
T H. 61 T H.
T
Net Dro
(Inches
n
'�. W_
Add
23-271/2
Stan
11 7JL4
EXIST
SEPTIC oravE
—12-LO2
5
SYST.
314
Add water
O�q, HOUSE
WELL
Date Readin 9
Clock
Time
Net Time
(minutes)
Percometer
Reading
Net Dro
(Inches
1-2111Z-
Add
23-271/2
Stan
11 7JL4
# 1
—12-LO2
5
22 It2
314
Add water
12:02:45
23 114
#2
12:07,45
11/16
at
12:08
#3
1213
5
1 2211116 1
3/4
Add water
12:13:30
123216
12:18:30
22 11 16
4
V I I PERCOLATION RATE 8 (minutesAnch) PERC HOLE DIAMETER 6
u TESTRUNBETWEEN 6,5 FT AND 7.0 FT
COMMENTS: The soil absorption system should be constructed in the vicinity of this test hole. Size trench on basis of 0.8 epolsq. ft.
PERFORMED BY FLATTOP TECHNICAL SERVICES. 1�,��'9k[ , CERTIFY THAT THIS TEST WAS PERFORMED IN
ACCORDANCE WITH ALLSTATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE. DATE: I / 29 1.9 7
FLATTOP TECHNICAL SERVICES
14530 ECHO ST.
ANCHORAGE, ALASKA 99516
TEST HOLE # 2 SOILS LOG - PERCOLATION TEST
LEGAL DESCRIPTION: Lot 4 Del's S/D
DATE PERFORMED: December 27, 1996
PERFORMED FOR: Pattv Barrack
PL
SM Gravelly silty loam
ML Gray gravelly silt
GM Brown silty gravel
Lenses of SPISM
Siltier and harder digging than T}I. M I
indistinct transition
ML Gravelly sandy silt
Dense, becomes
increasingly caked
with depth
Sidewalls do not smear
B.H.
SLOPE
Depth to Groundwater Date
No Groundwater 12127/96
Monitor tubed 1 7
w
Q.
O
m
Cc•s5�119
t ..;:.::
SITE PLAN
EAST 112th AVE.
T.H 61 IL
•1
c �+
m
EXIST
SEPTIC DHwE
SYST.
ya HOUSE
......................................... ............ au'70
017,
PERCOLATION RATE (minuteMnch) PERC HOLE DIAMETER
TEST RUN BETWEEN FT AND FT
COMMENTS: The soil encountered in this test hole is wgrifficantly sillier than &it encountered in T.H. l
PERFORMED BY FLATTOP TECHNICAL SERVICES. I � %1ti.CERTIFY THAT THIS TEST WAS PERFORMED IN
ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE. DATE: 1/2 9 /9 7
Tfattop ?echnica[Sen*es
14530 Echo Street, Anchorage, A 99516
Phone (907) 345-1355
Lot 4, Del's S/D
6200 East 112th Avenue
Wastewater disposal system installation
Specifications
1.0 General:
1.1 The scope of the project consists of abandonment of an existing 1000 gallon septic tank and
installation of a new 1000 gallon septic tank followed by 36 lineal feet of soil absorption trench containing
a total of 8.5 feet of sewer gravel.
1.2 Construction shall be as depicted on the approved site plan and design drawings. Minor
deviations from these drawings may be allowed or required by the engineer conducting the inspections.
All construction procedures and material specifications shall conform with Municipal and State
requirements. All separation distances shall be in conformance with Municipal requirements, unless
specifically waived.
1.3 The contractor shall be responsible to obtain any necessary utility locates, and to work around any
buried utilities. Z
1.4 The contractor shall provide adequate Otter aterial and rough grading over all system
components to ensure that proper drainage is achievad7fter settlement and that there are no residual
depressions. Insofar as possible the contractor shalE ' imiize damage to trees and existing lawn areas.
1.5 Unless specifically agreed otherwise, the homeoo6ner shall be responsible for finish grading after
the soil is compacted, as well as placement of topsoil and resgeding all areas disturbed by the construction.
2.0 Septic Tank:
2.1 The existing septic tank must be properly abandoned by thoroughly pumping, removing the top
and backfilling with soil.
2.2 The new 1000 gallon, 2 compartment septic tank shall be Municipally approved and shall be set
level on undisturbed soil. Each compartment shall be equipped with a watertight manhole cover and a 4"
cleanout. If the tank is buried less than 4 feet, it shall be insulated with 2 inches of approved burial type,
rigid insulation.
2.3 All pipe connections to the tank shall be equipped with waterproof mechanical couplings. The
waste line from the residence to the septic tank shall have a minimum slope of 1/4"' per foot, and the waste
line between the tank and the soil absorption system shall have a minimum slope of 1/8" per foot. A
cleanout shall be installed within 5 feet of the building foundation, and a double cleanout shall be installed
within 5 feet downstream of the septic tank.
3.0 Soil absorption system:
3.1 The soil absorption system shall be constructed by excavating a 36 foot long trench to a total depth
of 11 feet below original ground level in the vicinity of test hole #1.
3.2 The bottom of the excavation shall be level. Any compacted or smeared surfaces shall be raked to
allow proper infiltration. Sand for leveling or serving as filter material shall comply with Municipal
specifications.
3.3 A total of 8.5 feet of approved sewer gravel shall be placed in the bottom of the excavation with
the perforated distribution pipes laid level such that the pipe inverts are no less than 8.0 feet above the
bottom of the sewer gravel. Sewer gravel shall be 0.5" - 2.5" screened gravel, with less than 3% passing
the #200 sieve.
3.4 Monitor tubes and cleanout pipes shall be of 4" diameter and installed in the locations shown on
the design drawings. The portion of the monitor tube extending through the sewer gravel shall be
perforated.
3.5 Approved filter fabric shall be placed over the entire top surface of the sewer gravel. A minimum
of 2 feet of soil cover is to be placed over the filter fabric. If the soil cover thickness is less than 3 feet,
two inches of rigid, burial type insulation is to be placed over the entire top surface of the gravel, in
addition to the filter fabric.
3.6 The top surface of the cover material shill iced a minimum of 12 inches higher than the
surrounding terrain to allow for subsequent settle nt nd shall be graded to smooth contours. Fill
slopes shall be no steeper than 3:1.
3.7 Unless specifically agreed otherwise the homeown r s be responsible for arranging to have the
site finish graded after the backfill material has stabilized, and placement of adequate topsoil and seed
to promote rapid revegetation of all areas disturbed by the construction.
4.0 Inspections:
4.1 A minimum of 4 engineering inspections will be required during the course of the project: (1)
initial stakeout with the contractor to establish the location of the system and to discuss the plans,
specifications and construction procedures, (2) after the native material has been excavated to expose the
infiltrative surface to ensure that it is level and at the right elevation, and conforms with the soil test
information, (3) after the sewer gravel is in place and the distribution pipes have been laid and connected
up to the septic tank, but prior to placement of insulation or filter fabric, and (4) after rough backfill and
grading is complete. The septic tank requires one inspection after it is set level and the piping connected,
but prior to backfill. This inspection may be incorporated with any of the above inspections.
4.2 The installer shall coordinate the timing of the inspections with the engineer sufficiently far in
advance to ensure the availability of the engineer.
' "A..
IF CONSTRUCT 36' SOIL ABS. LONG TRENCH
�— WITH 8' GRAVEL BELOW DISTRIBUTION PIPE
I
4• DIA F-810 PERF PIPE
T PLAN VIEW
SCALE: 1" =10' - 0"
;; y /----4• DIA. D3034 PIPE
u
.: I "A" <�
3
DBL C.O.
INSTALL
NEW 1000 GALLON
./—SEPTC TANK
DIA. D•D034 WASTE LINE FROM HOUSE
MONITORTUBE
CLEANOUT
MOUND COVER MATERIAL 12'
ORIGINAL GROUND
FILTER FABRIC
4• DIA. F-810 PERF. DIST. PIPE
SECTION "A - A"
SCALE: I" = 5'- 0"
-21/2• SEWER GRAVEL
TOM OF EXCAVATION
Ri
cd
co
,
Al
DBL C.O.
INSTALL
NEW 1000 GALLON
./—SEPTC TANK
DIA. D•D034 WASTE LINE FROM HOUSE
MONITORTUBE
CLEANOUT
MOUND COVER MATERIAL 12'
ORIGINAL GROUND
FILTER FABRIC
4• DIA. F-810 PERF. DIST. PIPE
SECTION "A - A"
SCALE: I" = 5'- 0"
-21/2• SEWER GRAVEL
TOM OF EXCAVATION
O'MALLEY ;
SCHOOL
Y
w
TRACT
�IQ
ABANDON
SEPTIC
TANK
FORSYTHE
PARK
L5, B4, SO. LAKEWOOD HILLS #1
EAST 112th AVENUE
CONSTRUCT 36LONG
SOIL ABS. TRENCH
WITH 8' GVL. BELOW PIPE
T.H.
M.T.
I
T.H.
0--#2
DBL.."
C.O. C.O.
,
\TANK oINSTNEW SEPT
DRIVE;
-------
��
GAR. 3 BOW
HOUSE
,
1 '
VR 1
LOT 400'
WELL
DEUS S/D
♦
♦
-------- --------------------------
100' FROM WELL
0 0
SEPTIC
c SYSTEM
0
HOUSE •••
,
,
,
,
—WELL
:
:
LOT 3
DEUS S/D
ALI
So$ 4c
�. ..... .- ..............
.
y
t • c-
h•ry
------------'---------------------- =20----0---20---40---60---80---100'
LOT 3, SHADOWBROOK S/D FEET
SEPTIC SYSTEM
GREATER THAN
100 FEET FROM
\ WELL
LOT 4
SHADOWBROOK S/D
MUNICIPALITY OF ANCHORAGE
J/• �� DEPARTMENT OF HEALTH & ENVIRONMENTAL PROTECTION
II ENVIRONMENTAL ENGINEERING DIVISION
825 L Street • Anchorage, Alaska 99501 Telephone 2644720
ONSITE SEWAGE DISPOSAL SYSTEM AND/OR WELL INSPECTION REPORT
I .
NAME l� .!
LAL)
'l
N NCk)�
HONE n1
EW
❑UPGRADE
MAILINGADDRESS to f� i7
LEGA/4 DESCRIIPPTION <
l� 0 1 I rJ
LOCATION R
NO. OF BEDROOMS
D
DISTANCE TO:
Well
/
�
Absorpto area
Dwelling
/
PERMIT NO ?
OO S3
E 2
W
ManufacturerMater
C Qe
me
No. of comps ms
Fa.
0
Liq.c �city�n gallons
(J
IF HOMEMADE:
Inside length
Width
Liquid depth
6 le
J0Z
DISTANCE TO:
Well
Dwelling
PERMIT NO.
_?~
Manufacturer
Material
Liquid rapacity in gallons
OWell
W =
DISTANCE TO:
QD
Foundation
Nearest lot line
�Q
PERMIT NC,? p
O 6
LL Z
H 2 W
No. of lines
Length of iqo
"/
Total lengt qj lines_7.
�" t •
Trench WI h
inches
Distance bejw, n ' as.
Ill
H
Top of the to finish grade
Material beneath tile
inches
Total eller - absorption area
W
Length
Width
Depth
PERMIT NO.
61-
Wd
Type of crib
Crib diameter
Crib depth
Total effective absorption area
W
a
DISTANCE TO:
Well
Building foundation
Nearest lot line
J
Class
Depth
Driller
Distance to lot line
PERMIT NO.
W
i
DISTANCE TO:
Building foundation
Sevaer line
Septic tank
Absorption area(s)
OTHER
PIPE 8447 1C tC.
SOIL TEST RATING ,
INSTALLER R
K
REMARKS
APPROVED DATE LEGAL b
znQ Q
72-013 IRev. 3178) L1
MUN I C I FFFL_ I TY OF= F=fr40H0RnGE a�k�
DEPARTMENT OP HEALTH AND ENVIRONMENTAL P�,TECTION
825 'L! STREET, ANCHORAGE, AK. 99S man in -�D
r, 264-4720�v
WELL FiNO ON—SITE SEFJER F='EFZM I
PERMIT NO. ( 800538 )
rn6Y1. 1
APPLICANT ALAN HANNON PO BX 10-473 ANCH 99511 344-2 7
LOCATION ROCKRIDGE P.D.
LEGAL 11LT 4 DEL'S S?D. LOT SIZE 53540 SQUARE FEST
TYPE OF SOIL ABSORPTION SYSTEM IS: TRENCH �' D
4D t�iws
i
MAXIMUM NUMBER OF BEDROOMS = 3 SOIL P.RTING CS FTlBP,>= 125
THE REQUIRED SIZE OF THE SOIL ABSORPTION SYSTEM IS: S;L5
E>EPTH= O LENGTH= 47' GRAVEL- DEPTH= 4 /()-
THE LENGTH DIMENSION IS THE LENGTH CIN FEET) OF THE TRENCH OR DRAINFIELD.
THE DEPTH OF R TRENCH OR PIT IS THE DISTANCE BETWEEN THE SURFACE OF THE
GROUND AND THE BOTTOM OF THE EXCAVATION CIN FEET).
THERE IS NO SET WIDTH FOR TRENCHES.
THE GRAVEL DEPTH IS THE MINIMUM DEPTH OF GRAVEL BETWEEN THE OUTFALL PIPE
AND THE BOTTOM OF THE EXCAVATION (IN FEET).
REGtiU I REQ SEF T I C -rnNK S1=— 1I+00 GFFLLOtJS
PERMIT APPLICAFJT HAS THE RESPONSIBILITY TO INFORM THIS DEPARTMENT DURING THE
I14STALLATION INSPECTIONS OF ANY WELLS ADJACENT TO THIS PROPERTY AND THE
NUMBER OF RESIDENCES THAT THE WELL WILL SERVE.
--- TWO <2> I NSP'ECT I ONS RFRE REG+U I REG
BACKFILLING OF ANY SYSTEM WITHOUT FINAL INSPECTION AND APPROVAL BY THIS
DEPARTMENT WILL BE SUBJECT TO PROSECUTION.
MINIMUM DISTANCE BETWEEN A WELL AND ANY ON-SITE SEWAGE DISPOSAL SYSTEM IS
100 FEET FOR A PRIVATE WELL OR 150 TO 200 FEET FROM A PUBLIC WELL DEPENDING
UPON THE TYPE OF PUBLIC WELL.
MINIMUM DISTANCE FROM A PRIVATE WELL TO A PRIVATE SEWER. LINE IS 25 FEET AND
TO A COMMUNITY SEWER LINE IS 75 FEET.
WELL LOGS ARE REQUIRED AND MUST BE RETURNED TO THE DEPARTMENT WITHIN 30 DAYS
OF THE WELL COMPLETION.
OTHER REQUIREMENTS MAY APPLY. SPECIFICATIONS AND CONSTRUCTION DIAGRAMS ARE
AVAILABLE TO INSURE PROPER INSTALLATION.
F=�ERM I T EXP I RES D>ECEME aFZ 31.. 15?OE9
I CERTIFY THAT
1: I AM FAMILIAR WITH THE REQUIREMENTS FOR ON-SITE SEWERS AND WELLS AS SET
FORTH BY THE MUNICIPALITY OF ANCHORAGE.
2: I WILL INSTALL THE SYSTEM IN ACCORDANCE WITH THE CODES.
3: I UNDERSTAND THAT THE ON-SITE SEWER SYSTEM MAY REQUIRE ENLARGEMENT IF THE
RESIDENCE IS REMODELED TO INCLUDE MORE THAN 3 BEDROOMS.
SIGNED
Ij'ISSUED 8
i V4. 0
�Isr1 I c\�
OrEpwifivw of
0-s 'L'
a wEIS nir-4 ?
r�eM r tol ( sPkV5 33 )
-f -FLICANT num t"iFFC+Ft
uxarism Rocw.IDqE P.O.
LLQ -1- YT 4 OEL'�; 5/D.
1LL It 'r`l' r31~ f�Nti. 13Rf1(3�
t ll_rH Aii0'i7NER�31ihlENTFiI. PR�TECTIOH
osrPE£T, FkK,9"3E, FLK 93'S9 i
2134-472e r
ocTJ--sZ •f' �staE=R F -Etat -I r T
c^i
rtt RX
19-473 AWH -5r- ISLE -344-22T3 a
Lor b-tzc 33549 S9J R£ f 6Ef
rYP£ t3F SOIL Ao-;iVPrIOH SYSTEM TS: TROO:)i
TC,'�tlmum WTIOER OF •ECOPON45 a -3 SOIL Rnrim <se FT/BR>- 125
Sj
rW REQUIRCO s[Z£ OF THE 'SOIL Ficzt 'rtam StSTEM TS:
a
s<c;• rs 1= T_�r�r�'}-1� .-A-?
THE L:EIt3til OINF?751OM I5 THE L843T)1 <tN mo Of TFiE TMX -.H OR DRAINFIELO. ,�?
}I
TW- OEPTif OF A TMJCH OR PIT tS TWEDtifAt>'� 8Er1.1I�-N DIE-9JPFFiCE L THE
;,
*3RrXJNO r�[iO THE sormw OF THE oi:�mrIOtt <tN FEEr).
THERE tS TIO SET WIDTH FUR TR£Tr'-ES.
'
__ rHE_33A23VQ.f Tti IS. THE AEIA in.Lct'TH.OF .OkWELZEcnz°m-THE._OUTF.ilt..gff'£-
r iD ime oorrort aF rw £ o. -4T, Triom <t# rasm.
S:ErAw f i f�:Ei3 fsT Z r-• 'T'T--tt.tTC 5 1 vF� LL ►3s� rAL..t .ots[
r£RM[r FVPLICANT )3R% THE-RE51%5IBILIN TO INFORM THIS D RRTMENT tX1fM THE`
{
iN=TNLtRTtON [NSFEs;TifU i lTt pA::ENT TO THIS KOX'£QTY FM 71HE
mrw—R OF R£'SIDaces niRr TTA: W -L HILL %SCRdE
--- -r-wc-� <� sra•�f- Ec�-z r�ras t�rs� set;•�su =vi=a —
f3tN F[LLitMI OF ANY SrSTEM wtrimr-rmsL tNspw.rloN t14D PPPROVAL 9Y THIS
}
DEPPRITPUff wim ,ac --f3,tC k -:r To f`R<Tscurim
r
itlFliP$JM 0[STtlt#% 8=rt4E 4 A M -J- fV40 W? ON-SITE ISDIIlE OV-- SAL Vx5TE74 15
j
lEjiT FEET FOR A *ARIvATE wii- oR i59 TO dfiN rEEr FMN A PUSLiC 14ELL DEPEMINr3
i
UFFON THE rrPE OF -PUBLIC WELL.
MINIMUM DISTMX FROM tt-PRIVAT£ LIEU N A PR[VArC SEWr-R .LfHE IS .25 FEET ANO
T+3 n rY triN I TY 504ER LINE i5 ?5 ra f.
W -1-t. Will ARC-REaF1IRED AND w.;r 86 R£rURW-o To rw cycrApTFIENr 141THIN 30 cgr5
OF THE WELL CONPL.£ r L h
O T W -R W -GU I .REMENTS MW AAALY. SPEC rF I CR T I ONS FWD =6 TRUCT ION D I AOfi"ir 3 ARE
NdrlllflQLE To tIVS;URC PF.Of'ER W.5DI.LRTIOM
i-��r<•M 3 *r f-=:>Gf3 I
t CERTIFY THRT
L: I Ri FfIMiLIAR w[rH T'tie'. RcouIREFIE2Ir5-FOR ON -SIT£ SOrJ;2i At1D WF.LLa•ti5 5£f
FORTH 8Y TW- PliN I C I Ptd.. I TY LF W.Wlb)Rt3vlr-
2: [ 14ILL fWa iLL THC SeSTEM IN FiGCOR FOX WIT14 THE OJOE3.
-3: 1 LRIO£RS"rAW TMT TIE i3N-SITE SELLER SiSTEM FAY REojtR£ •op-i!p3cmcmr CF THE �
-RESIDE}t:;E IS RQ900CLED O tpo:LUOE mm TI4pm 3 sEDROOtK.
stcrsr-D�
•;f
V4. H
a
F_
r
P r;"
SPAE OF ipto A n-
:. f1Ai[IM6 ADORESS�,
5 WSTALtA7HHI tOCATI
LE6At SESCRW71W.-
MESA
DEIARTME F A17HhTWRDNMAMTALfRUTE NJ
• oWT&!¢r"RMfELIKRUrT/lFPLWATION
N- :
In
OPORADE
tO7 fizf: i /� .a S 30. fi. .: ; •.i: TYlf SF tERR11T: SEiIER
WELLHAMDWRMIN
oxowAel OWN?
COMBINED
.NUMBER OF fEDROOMS: 13 S®ILAA71N6:
TOTAL SE►1H: FT-
-7RESCR �oRAVE[ DFFTH: FT.
DRAW If to
FDR OF6RADE ONLY ADD
if 1 COLLECTED t'
"12 pmt
N6THANOWBADD CALLONTANK.
SEF ICER: IXT^
n SOILS LOG
MUNICIPALITY OF ANCHORAGE
*\NW DEPARTMENT OF HEALTH AND ENVIRONMENTAL PROTECTION ❑ PERCOLATION
Pouch 6
650, Anchorage, Alaska 99602 218-2221 TEST
SOILS LOG - PERCOLATION TEST
PERFORMED FOR: AL,,4♦\/ AIA"Amo4z DATE PERFORMED: Sr ---P7— !Z♦.CiRv
LEGAL
1I
2-
3,
4,
5
6'
7
8
9
10
11
12
13
14
15
16
17
18
19
--=.LOAAe --- - -
Sant o Y G-AvPL
- _ y(/�OGGA570n/AL
S/LT--�L NSE ;jw
_51 VJC
,IANoy G A
8oT_r0M_ _
�G _LEIJ,jES
ENCOUNTERED?
WATER L
ENCOUNTERED? 0
P
ay IF VES, AT WHAT E
MDEPTH7
A/Sz j 1.
110. =I.
i ffimmmmm
Reading
Date
Gross
Time
Net Depth to Net
Time Wim&-� � •�� Drop
.-- ; J
i'10011 It. 5 roar d fir/
754- •,: ��
��`ROFES 00P.�
20 -{
IL_ JI PERCOLATION RATE (minutes/inch)
TEST RUN BETWEEN SFT AND FT
�J
COMMENTS F - lA,4 n Ane, 7-1 A// L2•S �/g iPy
♦ - r '7 /
.�
PERFORMED BY: F --a s"_�, I�A.f'NA �-� CERTIFIED BV
72 008
72008 (7/78)
57-
I,r
r' n
{ `•' kov x uer 2 1975
'Paul 6. Hansen, P.E.
2525 t ast 88th Averilie
Anchorage, Alaska 99007
MUNICIPALITY OF ANCHORAGE
DEPT, OF HEALTH &
Mr. Ken Del fionlco ENJIROIWv1ENTAL PROTECTION
Star P.oute 'A" Box 26 950 $ � 141980
Anchorage, Alaska 97
SOILS EXPI"Vilom MI) PF.SOMIQi MIS RECEIVED
PROPOSED DEL'S SI,^ NYISIM.. LOTS 2, 3, 4 11
KEAJR O' A! t EY SCh^oL, f:;G"< " .°, ALI.M'
In accordance with your request, soils expinration and percolation testing
for on-site sewage disposal were perfon-ed on the three proposed lots.
Drilling was perfor.ed on Octo`Ser b, 1875 by Denali Drilling, Inc. of
Anchorage emloying a B-50 ibbile drill and consisted of three 20 -ft.
test holes; logging end percolation testing were perrorcited by vysPir
in accordance with the United Soil Classification Systm, the Sail Triangle,
and the "Manual or Septic -Tan! Practice'. Soils Here &ascribed and elassifi:d
in the field by means of i3tmaerous grab sagles.
Logs of test holes are found on Sheet 1; percolation test results are
on Shrats 2 and 3. Test hole locations have bezn plotted on yunr proposed
suk!ivisfon plat.
The property has ver; satisfactory draina;e to the norther^st, with it
atdxisurT relief of about 60 feet throu;hout the three lots. )!o standing
eater was noted. f:uxerous lar5e spruce and birch trees, up to 15 inches
in diameter, were observed,
In Senerel. the soils consisted of sand, silty sand, sandy silt, and
grav;,lly sandy silt (SP. 5K, M) of rxdi;,m d'ansity. Gravel end stall
coth,les were occusiontlly.encountcrcd. A tiater Cable was cncountarad
in Test Kole 0 (tot 4) only, at a depth of 1) feat. for this. Mason,
DO percolation test rias p,:rforc-d in 1.11. 3; hoxever, if necessary, an
on-site sewdge dispcs*.1 s}stm could be located in tis seus.harn 1•a -Ir
of tot 4, at a highzr ele aticrl, where the hater table is ex,% cteJ to
be at a greater depth. 1#R. 2 started to slough during the percolation
test, giving erratic rasults, so another test was performd in an ,adjacent
test hole (2A) with a staidpipt. ie -,t holes here fillW with t/atPr and
Saturated for at least 'Mbours prior.to p^rcolatien testinn. Tte two
percolation tests yielded!percolation rates or 2bout 9 vinute%/irrh,
3-1/2 to 4 hours artcr the tests b:.3an, corresNnding to z4out M square
fret or LbsoilTtion ere•c rtquired per t^drocrs- The test hale lot; :;euld
suggest a value of abntrt 2U0 square feet.
r
Hr. Ken Del Konica
hovenber 29; 1975 #
In my opinion, the three Pots appear satisfactory for thL, proposed
e development, in terms of surface drainage, founddtion soils, and on-
-site sewage disposal.
Of A g��i
PIItJL L. HIIPISEM, P.f. i�t1 _.� i •:��
s
...i f ._ •.•.��� y
Enclosures
PAVL C. IIA:SSL'1
1)YI
�'• � 1 LEST l±<lLE_I.0c;5 l) •
r '
lest Hole 1
Location: Lot 2
Elevation: 6841
Water Table While Drilling`- None
1. Water Table 24 Hours After Drilling - Hone
Dem Descrintion
0 to 6" Brown Organic Lover
6' to 4' Brown, FI Si%Sandy. Gravel, GR
4' to 12' Brown. fIES;:ry fodac�p, rine to reJiun Sand, Sp
with irequnt- gravel and cobbles, (maxiazm ize 40)
12' to 20' Bro:.m. F2, mi'st Silty Sand, Sit (possibly M.).
with randoat fine gravel--
lest Hole 2
Location: lot 3
Lleration: 680.1
Water Table While Drilling - pone
Water Table 24 Hours After Drilling - Rone
Depth Description
0 to 6" Broom OrgaAic Cover
6" to 3'Brown, roi.�i2 Silty cand, sii
3' to 6' Brown, mist, F4'9,irdy�, it
6' to 20' Brown, dist-dzPp, F�, t;onplastic Silty Sand, S,'4
with random fine to redlLm Gravel and 13-1/2 - 141.
Location: Lot 4
ticyation: 662' -
Water Table Pbile CrM ing - 12'?
Water lable 60 Hoers.11ftcr Drilling - 11'
Depth C�s�rip_ion
y OA
`JO 1 S 7
OJ,4- 5 M A r,b M uST' EF -
0
E
0 to 4" Brown Oric Cover
4' to 2' Brown.—F4.`tNf; nonplastic fine Sandy Silt, KI
2' to 4' Bram, F4, Grare_11 S'n8Y Silt, IENaci vn Size - 1-1J2'
4' to 7-1/2 Brw+n, F2,-rofst Siltg fine Sznd with random fine. gravel, Si•l
7-1/2' to 12' Brown, F2.• moist'Sii,Y fine - Ii-diw. Sand, Sii, possibly S4
12.' to 15' Bram, F2. vat SiTty �2ad, SM with rood,m Fine gravel m;jxiF%x;:
size - 1/2'
15' to 20' Brown, F4. bcit Gravelly Sandy Silt, KL with 10 to 20; Gravel
AIa E_ ._BV
Municipality of Anchorage
On -Site Water and Wastewater Program -
(907) 343-7904 s x E r Y
CERTIFICATE OF ON-SITE SYSTEMS APPROVAL
Parcel I.D. 015-492-04
1. GENERAL INFORMATION
Complete legal description
Expiration Date: `7 / °'[' —
Location (site address) 6200 E 112TH AVE. ANCHORAGE AK 99516
Current Property owner(s) RAJ DEO CHOUDHURY & MARGAERETE HAEUSLER Day phone
Mailing address
Real Estate Agent
6200 E 112TH AVE. ANCHORAGE AK 99516
2. TYPE OF DWELLING:
® Single Family (w/wo ADU)
❑ Duplex
❑ Multiple Dwellings (Single Family and/or Duplex)
Day phone
3. NUMBER OF BEDROOMS:
4
Receipt Number
Receipt Number
4. TYPE OF WATER SUPPLY:
Waiver #
TYPE OF WASTEWATER DISPOSAL:
Individual Well
®
Individual
Individual Water Storage
❑
Holding Tank
❑
Community Class Well
❑
Community
❑
Public Water System
❑
Public Sewer
❑
Received b J'
y: % � � � %'- � � Date: x /t
COSA to be released to the engineer, unless othep efyquested by the engineer.
COSA Fee $
Date of Payment 13
Waiver Fee $
Date of Payment
Receipt Number
Receipt Number
� 1 Na1� G�
COSA 4 V 7L/► -1 CID 0
Waiver #
5. STATEMENT OF INSPECTION BY ENGINEER
As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation,
based on procedures outlined in the Certificate of On -Site Systems Approval Guidelines for this application,
shows that the on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate
for the number of bedrooms and type of structure indicated herein. I further verify that based on the information
obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water
supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal and State codes,
ordinances, and regulations in effect at the time of installation.
Name of Firm ARCTERRA CONSULTING, INC. Phone 868.3791
Address 20441 PTARMIGAN BLVD., EAGLE RIVER. AK 99577
Engineer's Printed Name KENNETH M. DUFFUS Date ew�
Engineer's Comments: This investigation was completed in compliance with ADEC and MOA regulations. The assessment of the condition
of the well and septic applies only to the conditions as of the day tested. The flow and absorption rates may change due to subsurface
conditions that may not be observed from the surface, changes inland use, local soil characteristics, groundwater levels that may fluctuate
during the year and the water usage of the family being served by the system. The operational life of all well and septic systems are
subject to these various and dynamic characteristics and are outside the control of the
evaluator of the well and septic system. Therefore,
ArcTerra can not give any estimate of how long a
system will function satisfactory for current or future �t�,.
occupants or can ArcTerra guarantee that no unseen OF�I,
encroachments, deficiencies or discrepancies exist.
6. DSD SIGNATURE
System #1 Approved for bedrooms.
System #2 Approved for, bedrooms.
Disapproved.
Conditional approval for bedrooms, with the following stipulations:
Original Certificate Date:
of Anchorage is not responsible for errors or omissions in the professional engineer's work. i'l__
7. ATTACHMENTS:
COSA Checklist X
Septic System Advisory
Well Flow Advisory
J
Nitrate Advisory -Arsenic Advisory,
T
Other
4
If more than 1 septic system is on the lot:
COSA Checklist # of
Structure served by this system _
Certificate of On -Site Systems Approval Checklist
Legal Description: DEL'S LOT 4 Parcel ID: 015.492.04
A. WELL DATA
Well type PRVT
Date completed 1980
Total depth >162 ft.
Date of test
Static water level
Well production
If A, B, or C provide PWSID #
Sanitary seal (YIN) Y
Cased to *40+ ft.
FROM WELL LOG
WATER SAMPLE RESULTS:
ft.
9 -
p.m -
Coliform NEG colonies/100 mL Nitrate ND mg/L
Arsenic: ND ug/L Date of sample: 1117/12
B. SEPTIC/HOLDING TANK DATA
Tank Type/Material SEPTIC/STEEL
Tank size 1500 gal. Number of Compartments 2
Foundation cleanout (Y/N) Y Depression over tank (Y/N) N
Date of pumping 111712 Pumper A+
Well Log (Y/N) N
Wires properly protected (Y/N) Y
Casing height (above ground) 12+ in.
AT INSPECTION
111712012
134 ft.
9 -p -111 -
Collected by: ARCTERRA
Date installed 6/1011997
Cleanouts (Y/N) Y
High water alarm (Y/N) N
C. ABSORPTION FIELD DATA
Date installed 611011997 Soil rating (g.p.d./ft2 or ft2/bdrm) 0.8 System type TRENCH
Length 97 ft. Width 2 ft. Gravel below pipe 5.1 ft.
Total depth 7_6 ft. (Measured 1117112) Eff. absorption area 989 ft Monitoring tube Y Depression over field N
Date of adequacy test 111712012 Results (Pass/Fail) PASS For 5 bedrooms
Fluid depth in absorption field before test 34.2 in. Water added 1000 gal. New depth 46.8 in.
Elapsed Time: 1350 min. Final fluid depth 34.2 in. Absorption rate >= 600+ g.p.d.
Any rejuvenation treatment (past 12 mo.) (Y/N & type) N If yes, give date
D. LIFT STATION
Date installed
"Pump on" level at _ in
Datum
E. SEPARATION DISTANCES
WELL ON LOT TO:
Size in gallons
"Pump off' level at _ in.
Cycles tested
Septic tank/lift station on lot 1004
Absorption field on lot 1001+
Public sewer main 75'+
Sewer /septic service line 254
Animal containment areas 50'+
SEPTIC/HOLDING TANK ON LOT TO:
Manhole/Access (Y/N)
High water alarm level at
Meets alarm & circuit requirements?
On adjacent lots 1004
On adjacent lots 100'+
Public sewer manhole/cleanout 100'+
in.
Holding tank 100'+
Manurelanimal excrete storage areas 8T/Clt� f 3�
Building foundation 5'+ Property line 5'+ Absorption field 5'+
Water main 10'+ Water service line 101+ Surface water 1004
Wells on adjacent lots 100'+
ABSORPTION FIELD ON LOT TO:
Property line 1' (WR970012) Building foundation 10'+ Water main 10'+
Water Service line 10'+ Surface water 1004 Driveway, parking/vehicle storage 10'+
Curtain drain 50'+(NONEKNOWN) Wells on adjacent lots 100'+
F. COMMENTS
`Well casing depth per MOA records.
G. ENGINEER'S CERTIFICATION
I certify that 1 have determined through field inspections and review of
Municipal records that the above systems are in conformance with MOA
COSA guidelines in effect on this date.
Engineer's Printed Name KENNETH M. DUFFUS
Date 1 210 412 01 2
COS.A brown sheet9-1-12.doc
Municipality of Anchorage
Development Services Department
Building Safety Division E
On -Site Water and Wastewater Program `
4700 Bragaw Street
P.O. Box 196650
Anchorage, AK 99519-6650
www.muhi.org/onsfte
(907)343-7904
CERTIFICATE OF ON-SITE SYSTEMS APPROVAL
FOR A SINGLE FAMILY DWELLING
Parcell.D. 015.492-04
1. GENERAL INFORMATION
Complete legal description Dees Lot 4
Location (site address) 6200 E 112th Avenue, Anchorage
COSA # 08 6 13 1
Expiration Date: R— 13 - 0 Q
Current Property owner(s) Ian & Sharon Purdue Day phone
Mailing address 6200 E 112th Avenue, Anchorage, AK 99516
Lending agency
Mailing address
Real Estate Agent
Mailing Address
Day phone
Bill Babylon/ Prudential Real Estate Day phone 351.4762
3801 Centerpoint Dr., Suite 200, Anchorage, AK 99503
Unless otherwise requested, COSA will be held by DSD for pickup.
2. NUMBER OF BEDROOMS:
3. TYPE OF WATER SUPPLY:
Individual Well
Individual Water Storage
❑
Community Class Well
❑
Public Water System?
❑
TYPE OF WASTEWATER DISPOSAL:
Individual On-site ✓❑
Individual Holding Tank ❑
Community On-site ❑
Public Sewer ❑
The Municipality of Anchorage Development Services Department (DSD) issues Certificates of On -Site Systems
Approval (COSA) based only upon the representations given in paragraph 4 by an independent professional civil
engineer registered in the State of Alaska. Certificates of On -Site Systems Approval are required for the transfer of
title (except between spouses) for properties served by a single-family on-site wastewater disposal and/or water
supply system. DSD also issues COSAs upon request to homeowners. Certificates of On -Site Systems Approval
are valid for 90 days from the date of issue for properties served by a private or Class C well and may be reissued
with new water sample results. (Certificates may be reissued for a period of up to one year with valid water
samples.) Certificates are valid for one year for properties served by Class A or B wells or a public water system.
The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work.
4. STATEMENT OF INSPECTION BY ENGINEER
As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation,
based on procedures outlined in the Certificate of On -Site Systems Approval Guidelines for this application,
shows that the on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate
for the number of bedrooms and type of structure indicated herein. I further verify that based on the information
obtained from the Municipality of Anchorage flies and from my investigation and Inspection, the on-site water
supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal and State codes,
ordinances, and regulations in effect at the time of installation.
Name of Firm Watkins Engineering, Inc. Phone 907-349-1851
Address PO Box 110443, Anchorage, AK 99511-0443
Engineer's Printed Name Cindy W. EllisDate 5/6108
9
49-TH
Cifidy W. Ellis
5. DSD SIGNATURE CE -110S77 ;
Y,
J� Approved for bedrooms. .....
Disapproved. Wim.
Conditional approval for bedrooms, with the following stipulations:
Attachments:
COSA Checklist X Arsenic Advisory
Septic System Advisory
Well Flow Advisory
Nitrate Advisory
Maintenance Agreements
Supplemental Engineer's Report
Other
By: ( G^ Original Certificate Date: 7 _
(R. 11M)
Municipality of Anchorage ;
Development Services Department
Building Safety Division
On -Site Water & Wastewater Program '
4700 Bragaw Street
P.O. Box 196650
Anchorage, AK 99519-6650
www.muni.orglonsite
(907)343-7904
CERTIFICATE OF ON-SITE SYSTEMS APPROVAL CHECKLIST
Legal Description: Del's Lot 4 Parcel ID: 015-492-04
A. WELL DATA
Well type Private
Date completed 1980
Total depth >162 ft.
Date of test
Static water level
If A. B, or C provide PWS ID # NIA
Sanitary seal (YIN) Yes
Cased to 40+ ft.
FROM WELL LOG
ft.
, Well Log (YIN) No
Wires property protected (YIN) Yes
Casing height (above ground) 12+ in.
AT INSPECTION
5/92006 Test conducted by Gamess Engr.
135 ft.
Well production g.p.m. 5.2 g.p.m.
WATER SAMPLE RESULTS:
Coliform 0 colonies/100 mL Nitrate 0.211 mg/L Other bacteria 0 colonies/100 mL
Arsenic: ND mgA Date of sample: 4/042008 Collected by: Rocky TrainorANatkins Engr
B. SEPTIC/HOLDING TANK DATA
Tank Type/Material Septic/ Steel Date installed 6/11/1997
Tank size 1500 gal Number of Compartments 2 Cleanouts (YIN) Yes
Foundation cleanout (YIN) Yes Depression over tank (Y/N) No_ High water alarm (YIN) NIA
Date of pumping 08/072007 Pumper A+ Home Services
C.'ABSORPTION FIELD DATA
Date installed 6/11/1997 Soil rating (g.p.d./ft2 or ft=/bdrm) 0.8 System type Deep Trench
Length 97 ft. Width 2 - ft. Gravel below pipe 5.1 7 ft.
Total depth 7.2 ft. Eff. absorption area 989 ft2 Monitoring tube Yes Depression over field No
Date of adequacy test 5/92006' Results (PasslFail) Pass For 4 bedrooms
Fluid depth in absorption field before test 23 In. Water added 1005 gal. New depth 41 in.
Elapsed Time: 150 min. Final fluid depth 36 in. Absorption rate >= 600+ g.p.d.
Any rejuvenation treatment (past 12 mo.) (YIN & type) None Known If yes, give date
D. LIFT STATION
Date installed NA Size in gallons Manhole/Access (YIN)
`Pump on' level at _ in. 'Pump oft level at _in. High water alarm level at
in.
Datum Cycles tested Meets alarm & circuit requirements?
E. SEPARATION DISTANCES
SEPARATION DISTANCES FROM WELL ON LOT TO:
Septic tankllift station on lot 100'+ On adjacent lots 100'+
Absorption field on lot 100'*
Public sewer main 100'+
On adjacent lots 100'+
Public sewer manholelcleanout 100'+
Sewer /septic service line 25'+ Holding tank 100'+
Animal containment areas 5U+ Manure/animal excrete storage areas 88"
SEPARATION DISTANCES FROM SEPTICIHOLDING TANK ON LOT TO:
Building foundation 5'+ Property line 5'+
Water service line 90+ Surface wzter 100'+
Absorption field 10'+
Water main 100'+
Wells on adjacent lots 100'+
SEPARATION DISTANCE FROM ABSORPTION FIELD ON LOT TO:
Property line 1' "' Building foundation t0'+ Water main 100'+
Water Service line 90+ Surface water 100'+ Driveway. parking/vehicle storage 10'+
Curtain drain 50'+ Wells on adjacent lots 100'+
F. COMMENTS: ' Tested )y Gamess: "Horse corral on adjacent lot to east. "'Lot line waiver M970012
G. ENGINEER'S CERTIFICATION
I certify that I have determined through field inspections and
review of Municipal records that the above systems are in
conformance with MOA COSA guidelines in effect on this date.
Engineer's Printed Name Cindy W. Ellis
Date
COSA Fee $
Date of Payment 6LE )(4
Receipt Number 167 119
(Rev. 11/05)
Waiver Fee E
Date of Payment
Receipt Number
My W. Ellis
CE • 10577 : .
Municipality of Anchorage
• Development Services Department
Building Safety Division .. , .
On -Site Water& Wastewater Program
4700 Box Box19
wStreet
P.O. 19 650
Anchorage. AK 99519-6650
/onsit
www.muni.org/onsite
343-7 onsite
(907)343-7904
CERTIFICATE OF ON-SITE SYSTEMS APPROVAL
FOR A SINGLE FAMILY DWELLING
Parcell.D. 015'2-O7uCOSA# 01r)IQb
1. GENERAL INFORMATION Expiration Date: R - I .Si- 0
Complete legal description
Location (site address)
Current Property owner(s)
Mailing address
Lending agency
Mailing address
Real Estate Agent
Mailing address
DEL'S S/D• LOT 4
6200 EAST 112th • ANCHORAGE. AK 99515
DANA SEAGARS (C/O AGENT) Day phone 242-6388
(C/O AGENT)
Day phone
BARBARA HUNTLEY w/PRUDENTIAL Day phone 273-7269
3801 CENTERPOINT DRNE #200 • ANCHORAGE, AK 99503
Unless otherwise requested, COSA will be held by DSD for pickup.
2. NUMBER OF BEDROOMS: 4
3. TYPE OF WATER SUPPLY:
Individual Well
0
Individual Water Storage
❑
Community Class Well
❑
Public Water System
❑
TYPE OF WASTEWATER DISPOSAL:
Individual On-site
Individual Holding tank
❑
Community On-site
❑
Public Sewer
❑
The Municipality of Anchorage Development Services Department (DSD) Issues Certificates of On -Site Systems
Approval (COSA) based only upon the representations given in paragraph 4 by an Independent professional civil
engineer registered in the State of Alaska. Certificates of On -Site Systems Approval are required for the transfer
of title (except between spouses) for properties served by a single-family on-site wastewater disposal and/or
water supply system. DSD also Issues COSAs upon request to homeowners. Certificates of On -Site Systems
Approval are valid for 90 days from the date of issue for properties served by a private or Class C well and may
be reissued with new water samples. (Certificates may be reissued for a period of up to one year with valid water
samples.) Certificates are valid for one year for properties served by Class A or B wells or a public water system.
The Municipality of Anchorage Is not responsible for errors or omissions in the professional engineer's work.
4. STATEMENT OF INSPECTION BY ENGINEER
As certified by my seal affixed hereto and as of the validation date shown below, I verify that y _
investigation, based on procedures outlined in the Certificate of On -Site Systems Approval Gfiidelines for this application,
shows that the on-site hater supply and/or wastewater disposal system is (are) safe, functional and adequate_
for the number_ort( drooms and type of structure indicated herein. I further verity that based on the
inforAatidn obtained from the Municipality of Anchorage riles and from my investigation and inspection, the
on-site water supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal
and State codes, ordinances, and regulations in effect at the time ofinstallation.
Name of Finn GARNESS ENGINEERING GROUP, Ltd. Phone
Address 3701 E. TUDOR ROAD, SUITE 101 • ANCHORAGE, AK 99507
Engineer's Printed Name JEFFREY A. GARNESS, P.E.
Engineer's Comments:
In conducting this evaluation, GEG, Lt D. attempted to provide a thorough,
conscientious engineering analysis of the system In accordance with ADEC and MOA
DSD Guidelines B Regulations. The reported results described the performance oftho
system under the conditions encountered at the time of the test, and separation
distances measured to readily idontifiable features. The operational life of all wells and
septic systems depend on the local soils condition, groundwater levels that may
fluctuate during the year, and the water usage of the family being served by the system.
These conditions are outside the control of the evaluator of the system. Satisfactory test
results do not guarantee future performance of the system, nor do they guarantee that
there are no hidden defects orencroachments. GEG, LTD. can therefore not provide
any warranty,or future estimate of how long the system will continue to meet the
operational requirements of the ADEC or MOA DSD. The content of this report Is for
the sole benefit of the owner listed above. Any reliance upon or use of this report by any
other person orparty is not authorized, nor will it confer any legal right whatsoever.
5. DSD SIGNATURE
Approved for 4 bedrooms.
Disapproved.
337-6179
Date _d,74
Conditional approval for bedrooms, with the fllowing stipulations:
Attachments:
COSA Checklist
Septic System Advisory
Well Flow Advisory
Nitrate Advisory
Arsenic Advisory
Maintenance Agreements
Supplemental Engineer's Reort
Other
ON-SITE
WATER AND
WASTENIATER
PROGRAM
is ••....• .c
By: V /Oct^' ` Original Certificate Date: S—_ " O
IRr f R51
Municipality of Anchorage
• Development Services Department
Building Safety Division .
Onsite Water b Wastewater Program
4700 Bragew Street
P.O. Box 196650
Anchorage, AK 995198850
www.muni.orglonsite
(907)343-7904
CERTIFICATE OF ON-SITE SYSTEMS APPROVAL CHECKLIST
Legal Description: DEL'S S/D: LOT 4. Parcel 113:016' 4 9 Z - 01�
A. WELL DATA
Well type PRIVATE If A, B, or C provide PWSID# N A
Date completed 1980 Sanitary seal (YIN) YES
Total depth > 162 ft. Cased to 40+ ft.
FROM WELL LOG
Date of test �C)G
Static water level
Wee production �G o.p.m.
WATER SAMPLE RESULTS:
Coliform 0 colonies/100 ml. Nitrate _NQ rngA.
Well Log (YIN) NO
Wires property protected (YM) YES
Casing height (above ground) 12+ in.
AT INSPECTION
5/9/2006
135 ft.
5.2 g.p.m.
Other bacteria 0 oolonies/100 mi.
Arsenic: N_ug./L. Date of sample: 4/27/2006 Collected by: GEG Ltd.
B. SEPTIC/HOLDING TANK DATA
TankTypelMateriat SEPTIC/STEEL Date installed 6/10/1997
Tank size 1500 gal. Number of Compartments 2 Clesnouts (Y/N) YES
Foundation cleanout (Y/N) YES Depression over tank (YIN) NO High water alarm (Y/N) N/A
Date of pumping 4/27/2006 Pumper McDONALDS PUMPING
C. ABSORPTION FIELD DATA 16AELOW EXISTING EM
Date installed 6/10/1997 Soil rating .p.d. ft%drn) 0_8 System type TRENCH
Length 97 ft. Width 2 ft. Gravel below pipe 5.1 ft.
Total depth 7.2 ft. Eft. absorption area 989 ft' Monitoring tube YES Depression over field NO
Date of adequacy test 5/9/2006 Results (Pass/Fall) PASS For 4 bedrooms
Fluid depth in absorption field before test 23 In. Water added 1005 gal. New depth 41 in.
Elapsed Time: 150 min. Final fluid depth 36 k1. Absorption rate >= 600+ g.p.d.
Any rejuvenation treatment (past 12 moa (YM & type) NONE KNOWN If yes, give date
D. LIFT STATION
Date installed
"Pump on" level at _in.
E. SEPARATION DISTANCES
Size in gallons
High water alarm level at
Cycles tested Meets alarm & circuit requirements?
SEPARATION DISTANCES FROM WELL ON LOT TO:
Septic tank/lift station on lot 100'+ On adjacent lots 100'+
Absorption field on lot 100'+ On adjacent lots 100'+
Public sewer main N/A
Sewer /septic service line 25'+
Public sewer manhole/cleanout N/A
Holding tank
Animal containment areas 50'+ Manurelanimal excrete storage areas 87'
SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK ON LOT TO:
Building foundation 5'+ Property line 5'+ Absorption field 100'+
Water main N/A Water service line 10'+ Surface water 100'+
Wells on adjacent lots 100'+
SEPARATION DISTANCE FROM ABSORPTION FIELD ON LOT TO:
Property line *11 Building foundation 10'+ Water main N/A
Water service line 10'+ Surface water 100'+ Driveway, parkingivehicie storage 10'+
Curtain drain 50'+ Wells on adjacent lots 100'+
F. COMMENTS
•WR970012
G. ENGINEER'S CERTIFICATION
I certify that I have determined threugh field inspections and
review of Municipal records that the above systems are in
conformance with MOA COSH guidefines in effect on this
date.y . Go ... ss........
'• a
Engineer's Printed Name JEFFREY A. GARNESSpew ' CE //
Date 5117 06 ��•r a 5//7'!¢66 `
COSA Fee S
LJ
Date of Payment
5/
Receipt Numbera/�o
(Rev. 1 IM)
Waiver Fee $
Date of Payment
Receipt Number
MAY -17-2006 1325 PRUDENTIAL. VISTA REAL EST 907 562 5485 P.02
FFft : G2JLERT ✓ FAX N0. : 9073450037 " 1 Apr. 16 2001 11:39AM P2
• O
•t M
S 88'59103"E 165.00'
a
P-41
1 "=30'
30.3'
smnc %Ws
1i
t
AG DRIVE
CWU4 1,
gl a
WELL
■
LOT 4
45.7
F0' T.dcE------------1
.,.
£0'd -"101
£d Wd6£:TT TOOZ 91 •add
£0'd serS Z9S L06
�•
n N
4MOSt£4E6 : 'ON XVd lar - J WMU
lS3 -AM VISM-UI1N3(IrOd SZ:£T 90OZ-LT-),W
J
e
w
,
r
•
�
I
W
:►ori
b
o
s
C
t
o
per
a
e
Qs
P c
O
£d Wd6£:TT TOOZ 91 •add
£0'd serS Z9S L06
�•
n N
4MOSt£4E6 : 'ON XVd lar - J WMU
lS3 -AM VISM-UI1N3(IrOd SZ:£T 90OZ-LT-),W
uwM-
Municipality Of Anchorage
. .mea ee
Development Services Department
Building Safety Division
On -Site Water and Wastewater Program ,$ • r
4700 South Bragaw St.
P.O. Box 196650 Anchorage, AK 99519-6650.
www.ci.anchorage.ak.us .
(907) 343-7904
..CERTIFICATE OF HEALTH AUTHORITY APPROVAL'
FOR A SINGLE FAMILY DWELLING
Parcelit! - 9Z-011 _ HAA#
Expiration Date: g • O /
1. GENERAL INFORMATION
Complete legal description L o11 -1,1—P e /Jr S iD
Location (site address or directions) • e Z o0 E l l Al- eA.e
Current Propertyowner(s) : fkL en keir, Day phone'•2-r2-ZZzy
Mailing address 62oa E I t 2 M A—L A++c6o- Ak .99s11
Lending agency
Mailing address
Real Estate Agent
Day phone
Real Est Day phone 2'7. - Z i I Y
Mailing Addressy 2 yl �t3 S>t. , A,_CA&r-uye, A -k 915-07 -
Unless otherwise requested, HAA will be held by DSD for pickup.
2. NUMBER OF BEDROOMS:
S
3. TYPE OF WATER SUPPLY:
TYPE OF WASTEWATER DISPOSAL:
Individual Well
®
Individual On-site
Individual Water Storage
❑
Individual Holding tank
❑
Community Class Well
❑
Community On-site
❑
Public Water System
❑
Public Sewer
❑
The Municipality of Anchorage Development Services Department (DSD) Issues Certificates of Health Authority
Approval (HAA) based only upon the representations given in paragraph 5 by an Independent professional civil
engineer registered in the State of Alaska. Certificates of Health Authority Approval are required for the transfer of
title (except behveen spouses) for properties served by a single family on-site wastewater disposal and/or water
supply system. DSD also issues HAAs upon request to homeowners. Certificates of Health Authority Approval are
valid for 90 days from the date of issue for properties served by a private or Class C well and may be reissued with
new water sample results less than 30 days old. (Certificates may be reissued for a period of up to one year with
valid water samples.) Certificates ere valid for one year for properties served by Class A or B wells or a public
water system. The Municipality of Anchorage is not responsible for errors or omissions in the professional
engineer's work.
4. STATEMENT OF INSPECTION BY ENGINEER
As certified by my seal affixed hereto and as of the validation date shown below. I verify that my investigation,
based on procedures outlined in the Health Authority Approval Guidelines for this application, shows that the
on-site water supply and/or wastewater disposal system is(are) safe, functional and adequate for the number of
bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the
Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or
wastewater disposal system is(are) in compliance with all applicable Municipal and State codes, ordinances,
and regulations in effect at the time of installation.
NameofFirm Flu1-101 icchnfta/ Sucf Phone 3`/5• 1?S'S—
Address /'/S?0 Ertie SZ. ,4AC erc4G Ak 99S1�
Engineer's Printed Name T/+eo dui F /` rte oK Date raiz I4 2-00 i
5. DSD SIGNATURE
.Approved for Jr bedrooms.
Disapproved.
�r�r R4 ee....•• 1Y•w�O.
'i' ,•' Ty-d'>„� NGINEER'S
4ISTAMP
: THCM0:!. F.
Cz-35.9 x`
Conditional approval for bedrooms, with the following stipulations:
Additional Comments
Attachments:
HAA Checklist x
Septic System Advisory
Well Flow Advisory
WATERAND
: WAS I L WATF'
PROGRea
Y•�
Maintenance Agreements
Supplemental Engineers Report
Other
By: �� Original Certificate Date: 3 O — t7 /
(Rev. I=C)
Municipality of Anchorage
Development Services Department
Bullding Safety Division
On -Site Water & Wastewater Program :
4700 South Bragew St.
P.O. Box 196650 Anchorage, AK 995196650
www.dAnchorageAk.us
(907)343-7904
HEALTH AUTHORITY APPROVAL CHECKLIST
Legal Description: % o A '�, D e/ 's S /'D
Parcel ID: O 15 - 1 9 2- 0 Y
A. WELL DATA
Well type Pvf If A. B. or C provide PWSID 0 _
Well Log (YM) N
Date completed Y 9 6p Sanitary seal (Y/N) Y
Wires properly protected (YIN) Y
Total depth > 2±i t ft. Cased to> i 62 tt.
Casing height (above ground) i_in.
FROM WELL LOG
AT INSPECTION
Date of test
5,/ 16 /0 /
Static water level ft.
17'3 ft.
Well production 9•p•m•
6. i g.p.m.
WATER SAMPLE RESULTS:
Coliform _ _cdonies/100 ml. Nitrate 0. mg.A.
Other bacteria 0 colonies/100 ml.
Date of sample: S//6/o1 Collected by: F/wNcf.
B. SEPTIC/HOLDING TANK DATA
Tank Type/Material 94,. he / Il—rat
Date installed
Tank size 150// gal. Number of Compartments 2_
Cleanouts (Y/N) 1'
Foundation cleanout (Y/N) Y Depression over tank (YM)
At High water alarm (Y/N) N. A _
Date of pumping 9!2.61 2000 Pumper DeAR 1 i
C. ABSORPTION FIELD DATA
Date installed 6/ 1or97 Soil rating (g.p.d./ft= or ft21bdrm) O. A System type Teenci
Length 9-7 ft. Width T-0
ft. Gravel below pipe S• 1 ft.
Total depth 7, 2 ft. Eff. absorption area ,QB9 ft' Monitoring tube Y Depression over field A/
Date of adequacy test S'11,<161 Results (Pass/Fail) Pal t For _- bedrooms
Fluid depth in absorption field before test 2_%Xin. Water added 75'3 gal. New depth4= in.
Elapsed Time: 147 min. Final fluid depth 3 in.
Absorption rate >= -75ld g.p.d.
Any rejuvenation treatment (past 12 mo.) (Y/N 8 type) N6n e- feno w^ If yes, give date N • A.
i
D. UFT STATION Noe e
Date installed
"Pump on" level at _ in.
Datum
E. SEPARATION DISTANCES
Size in gallons
"Pump otr level at _ in.
Cycles tested
SEPARATION DISTANCES FROM WELL ON LOT TO:
Septic tankfltft station on lot 16 S
Absorption field on lot
Public sewer main M • A•
Manhole/Access (YIN)
High water alarm level at in.
Meets alarm & circuit requirements?
On adjacent lots > 10c'
On adjacent lots > lac.
Public sewer manhole/cleanout IJ.
Sewer /septic service line z s ' Holding tank N. A
SEPARATION DISTANCES FROM SEPTICIHOLDING TANK ON LOT TO:
Building foundation 100 Property line ?6" Absorption field 1 C '
Water main > 2r, Water service line 2s'' Surface water > rao'
Wells on adjacent lots > t UG '
SEPARATION DISTANCE FROM ABSORPTION FIELD ON LOT TO:
Property line 1 ' Building foundation 12 6" Water main > ts"
Water Service line > >-s' Surface water > ! as ' Driveway, perking/vehicle storage 10 '
Curtain drain Moee tern Wells on adjacent lots fir' '
F. COMMENTS
G. ENGINEER'S CERTIFICATION
1 certify that 1 have determined through Recd inspections and
review of Municipal records that the above systems are in
conformance with MOA HAA guidelines in effect on this date.
Engineer's Printed Name TAsada rG F. 1'1&0 -'e -
Date S/ZS /&f
G 2a
-it
A
HAA Fee $ 3 oG Waivgr, $
h+N
Date of Payment / 2 /O f DateWayment
Receipt Number S Rec"umber
.4
(Rsv. 12M) 0
N \
•+ N
ID VI
a\
N O
r
r
r
M u
WA
C� A
GD
n
4J
;-49T=r'i F1
cr
rprpF. LtOORE'• �c
T .3589 F
.• �' f
MUNICIPALANCHORAGE
DEPARTMENT OF HEALTHEALTH8 HUMAN SERVICES.
• Division of Environmental Services
On -Site Services Section
P.O. Box 196650 Anchorage, Alaska 99519-6650
343-4744
CERTIFICATE OF HEALTH AUTHORITY
APPROVAL FOR A SINGLE FAMILY DWELLING
Parcel l.D.# 0157 192 0Y cmcp HAA# "(12 )LVO3a
GENERAL INFORMATION
Complete legal description Vf `l. De I s SID
Location (site address or directions) 6 200 E f, 2 t" Ate
Pro pertyowner MQ-rh^ i P�tf-r(eiu ecvf�xck- Day phone .Y6'2i.7
Mailing address 6200 E f 1 Z r" f}ve A} c�, h+•c 995-ier,
Lending agency VIS Aa "00,)Lg4e Day phone Z 73 - 7 7&3
Mailing address ye ql 'C s/Is Asch ofayg f}cc 99S03
Agent Ctiru Sw(,-u, 1/uj4x 8ee' r=A*/e Dayphone .76z -6Y641
Address y e bi �6 S�, i4�ge. Air 99S03
Unless otherwise requested, HAA will be held for pickup.
2. NUMBER OF BEDROOMS: •S
3. TYPE OF WATER SUPPLY:
Individual well t'
Community well
Public water
NOTE: If community well system, provide written confirmation from State ADEC attest-
ing to the legality and status of system.
4. TYPE OF WASTEWATER DISPOSAL:
Individual on-site V_�
Holding tank
Community on-site
Public sewer
NOTE: If community wastewater system, provide written confirmation from State ADEC
attesting to the legality and status of system.
72425(RN.+A+) From MOAK1
S. STATEMENT OF INSPECTION BY ENGINEER
As certified by my seal affixed hereto and as of the validation date shown below, l verify that my
Investigation of this Health Authority Approval application shows that the on-site water supply
and/or wastewater disposal system is safe, functional and adequate for the number of bedrooms
and type of structure indicated herein. I furtherverify that based on the information obtained from
the Municipality of Anchorage files and from my investigation and inspection, the on-site water
supply and/or wastewater disposal system is in compliance with all Municipal and State codes,
ordinances, and regyfations in effect on the date of this i spection.
RGi1-r"4tR cC o reeY tact( l%f}N k' elemma% cono(;Ae:AA�sooee •./.�•r.d¢ fu.••r
Name of Firm F/crf-L4 T�cAn%cu/ Sa•-v;cPhone 3Y.S- i?S3-
Address HS'3o Echo Sf.. AncAor;ge Ak 99S/,<
Engineers signature -71 -4 - 1: 9' Date 6/ i6 19 7
The Municipality of Anchorage Department of Health and Human Services (DHHS) issues Health Authority
Approval Certificates based only upon the representations given in paragraph 5 above by an independent
professional engineer registered in the State of Alaska. The DHHS does this as a courtesy to purchasers of homes
and their lending institutions in order to satisfy certain federal and state requirements. Employees of DHHS do not
conduct Inspections or analyze data before a certificate Is issued. The Municipality of Anchorage is not
responsible for errors or omissions in the professional engineers work.
rams (a+. M) 8• MOA M
mac. ,,�,-
4J ;Gal�r.
'B,t
6. DHHS SIGNATURE
;:,�•.� Cc • CSo�
PP for
Approved S
•��••""
bedrooms. �_•: � ..�
V+•C+ s„S1.7
Disapproved.
Conditional approval for
bedrooms, with the following stipulations:
Additional Comments
BY:
Date LZL27
The Municipality of Anchorage Department of Health and Human Services (DHHS) issues Health Authority
Approval Certificates based only upon the representations given in paragraph 5 above by an independent
professional engineer registered in the State of Alaska. The DHHS does this as a courtesy to purchasers of homes
and their lending institutions in order to satisfy certain federal and state requirements. Employees of DHHS do not
conduct Inspections or analyze data before a certificate Is issued. The Municipality of Anchorage is not
responsible for errors or omissions in the professional engineers work.
rams (a+. M) 8• MOA M
Municipality of Anchorage
DEPARTMENT OF HEALTH HUMAN SERW E I V E D
Environmental Services Division
825*V Street, Room 502 0 Anchorage, Alaska 995010 (907) 343-4744
JUN 17 1997
Municipality of Anchorage
Health Authority Approval ChecklisPept. Health A Human services
Legal Description: L o t X Del 's' S /D Parcel I.D.: O IS- 'V 9 z G Y 0 0 0
A. WELL DATA
Well type P v t If A. B, or C. attach ADEC letter. ADEC water system number
[.08 Present (Y/N)
N
Date completed Now - O•c , 1960
Total depth 15-6 Cased to IS -6, Casing height (above ground) I if "
Sanitary seal (YIN) Y Wires Properly protected (YIN) `r
FROM WELL LOO
Dau of test
Static water level
Well production
WATER SAMPLE RESULTS:
AT INSPECTION
26'
&P.m. 6. os
&P•>a
Coliform O
cam( /tun m -C
Nitrate < o. / �'t
/-t
Odderbacteria
Ne,4w Reoa�imd
Date of sample:
1 /3/?7
Collected by:
F (a
Ncr TecA
S -c
B. SEMCOOLDING TANK DATA
Date installed 461 u /9 7 Talc dze1s 9 Number of Compartments Z_ Cieanouts
Foundation cleanout (Y" Y Depression (Y" N high water alarm (Y/M M.4.
Dau of Pumping N. A 07 dwJ bumper N. A.
C. ABSORPTION FIELD DATA
Dau installed 0/11 / 9 7 Soil rating (g p d /ft= or ftrlbdtm) yate o type 7-reA c A
r�
Length 97' Width 2 Gravel thickness below pipe S • 1 Total depth 7. '/
Effective absorption area 989 0' Monimmg Tube present(Y/N) Y Depression over Geld (Y" N
Date0f adetluacy test N-4. 60~) )results (Paas/Fdq Pau For s bedrooms
Fluid depth in absorption Geld before test (in.), 0 Immcdisteky after_ gal. water added 00:
Fluid depth (ins.) Minutes later: Absorption rate . s.pd.
Permude treatment (past 12 months) (YHA N If yes, give daze N• 6.
D. LIFT STATION N• A.
Date installed
Manhole/Acoess (Y/1)
High water alarm level at*
Cycla tested
E. SEPARATION DISTANCES
Size in gallons
"Pomp on" level aN
*Datum
"Pomp or level at*
SEPARATION DISTANCES FROM WELL ON LAT TO:
Septidbolding tank on tot 16 S , ; On adjacent lots > t o o
Absorption fold on lot los" ; On agjamnt tors > tat,,
Public server main N. A. Public sewer manhoWcleanoot N• �.
Sewer /septic service line > ZS' Lift station N. A
SEPARATION DISTANCESS FROM SEPTICJHOIDINO TANK ON LOT TO:
Building frundadon 100- ply Une 3f' Absorption field f o '
Water main/servtee line >10_Surface wateddtainage > t co ' Wetts on adjaccut lots > tog'
SEPARATION DISTANCE FROM ABSORPTION FIELD ON LOT TO:
Building foundation 1 ?01 Property Line 1' Water mmuftrvm line _ > t o '
Surfacewater > t ori ' Driveway, patkingNehicle storage area t S' '
Curtain drain None s e to Wells on adjacem lots > t uo
F. ENGINEER'S CERTIFICATION
I off* that I have detemuned Aru Jleld hapections and review ofMmridpal records that the Symms mr
In conformance with MOA HAA guidelines in e•(feei on this date. oG'Fc of "E"
u n ton .A. fw.►s / µi}A �� t„ ,rF e47
Signadne T— % t.. �.
Eugineer's Name %X err oda, �e F. nvc,-
Date 6/l6 /97
HAA Fee S
Date of Paymtmt
Receipt Number
Rev. 8/95 OSS: haawk.doc
Waiver Fee S
Date of Payment
Receipt Number
..................:
MUNICIPALITY OF ANCHORAGE
• DEPARTMENT OF HEALTH & HUMAN SERVICES.
Division of Environmental Services
On -Site Services Section
P.O. Box 196650 Anchorage, Alaska 99519-6650
343-4744
CERTIFICATE OF HEALTH AUTHORITY
APPROVAL FOR A SINGLE FAMILY DWELLING
Parcel I.D. # Ors 192 oy Dao HAA 4 "(� 'C 1 rnL�
1. GENERAL INFORMATION
Complete legal description Gof °ly De/s -S/D
Location (site address or directions) 4r2aa /1 z
Propertyowner i Va}rlc1g barrack Dayphone 3y6^2139
Mailing address 20o E rr2 f"f}vr A^�A&. aye ,4r� 9151
LendingagencyV1t�l�O^t_yage ('A4m^ScotlDayphone a73-7797_
Mailing address At 2 If 1 "13 SA A,,cA&r a4 A k 99So3
Agent C4r4 Sc.;#re _ Vtxlu Rear JQ�afe Day phone S6 z -6yGy
Address H 2 y 1 "6" Sf. /F^ �o 7 . f/ k 91S'03
Unless otherwise requested, HAA will be held for pickup.: Pl t -'adi1 2z3 -778 ASAP
2. NUMBER OF BEDROOMS:
9 � •�,;A' : r�e�ry:"- ar Pickap
3. TYPE OF WATER SUPPLY:
Individual well
Community well
Public water
NOTE: If community well system, provide written confirmation from State ADEC attest-
ing to the legality and status of system.
4. TYPE OF WASTEWATER DISPOSAL:
Individual on-site '� ^
Holding tank -
Community on-site =
Public sewer
NOTE: If community wastewater system, provide written confirmation from State ADEC
attesting to the legality and status of system.
72-MCA"AM) imm MOA121
5. STATEMENT OF INSPECTION BY ENGINEER
As certified by my seal affixed hereto and as of the validation date shown below, I verify that my
Investigation of this Health Authority Approval application shows that the on-site water supply
and/or wastewater disposal system Is safe, functional and adequate for the number of bedrooms
and type of structure indicated herein. I further verify that based on the information obtained from
the Municipality of Anchorage files and from my investigation and inspection, the on-site water
supply and/or wastewater disposal system Is in compliance with all Municipal and State codes,
ordinances, and regulations in effect on the date of this inspection. Canpffxcna/ ftAA
rlrr U Ae,(. r ee ct, complehc4 otf-{'I�fi� 4�9'vw c(( rn tu�nw+lr r97
Name of Firm 1=ruf��7 TitfAnrcalSPivrr¢i ✓ Phone 7Ns-13sS
Address lyS3v .9 is,
Engineers signature Date //?-:P/ 97
6. DHHS SIGNATURE
Approved for bedrooms.
"WE F. NOORE
CE -Z589
Disapproved.
Conditional approval for -kms bedrooms, with the following stipulations:
Additional Comments Money shall be put in escrow to construct an upgraded waste—
water system to serve this dwelling pursuant to permit number SW970012 attached.
The construction shall he rnmaleted no later than jtinp 15, 1997 Mnney in "
escrow shall not be released until final approval has been given by'this
By ��9`--r7" Date / " 30 — 2 %
CAUTION
The Municipality of_'
Department of Health and Human Services (DHHS)'issues Health Authority
Approval Certificates based only upon the representations given In paragraph 5 above by an independent
professional engineer registered in the State of Alaska. The DHHS does this as a courtesy to purchasers of homes
and their lending Institutions in orderto satisfy certain federal and state requirements. Employees of DHHS do not
conduct inspections or analyze data before a certificate Is issued. The Municipality of Anchorage is not
responsible for errors or omissions in the professional engineers work. '
724025 p+«. 1N9 Beck MOAM
Municipality of Anchorage
DEPARTMENT OF HEALTH & HUMAN SERVICES
Environmental Services Division
825wV Street, Room 502 • Anchorage, Alaska 99501 • (907) 343-4744
Health Authority Approval Checklist
Legal Description: ko>` MjDela S/fi Parcel I.D.: O /S `192 OY D00
A. WELL DATA
Well type P v 1 if A. B. or C. attach ADEC letter. ADEC water system number
Log present (YIN) N Date completed No v - De c , 19 80
Tara) depth iso' Cased to 13- 6 Casing height (above ground) 16
Sanitary scat (YIN) Y Wires properly protected (YIN) Y
FROM WELL LOO AT INSPECTION
Date of test 12 / uz / 94r
Static water level
Well production g.p.m. 6. GS g.p.m.
WATER SAMPLE RESULTS:
Coliform 0
co I
/ Ino dm L
Nitrate /-4-"
Other bearria Alone --4001-Oro!
Date of sample:
1/3/27
Collected by: F
/a /`/y o T.-cA S'c-c
B. SEPTIC/HOLDING TANK DATA
Date installed lO / 13 /8ev Tonic sit j&oo,,X Number of Compartments ? Cleanouts (Y/M—r_
Foundation cleanest (Y/M Y' Depression (Y" N High water alarm (YRS 14 -A -
Date of Pumping 8/ 26!96 Pumper A +-
C. AMRP'I'ION FIELD DATA
Date installed 101131,*V Soil rating (g p.d./il= or Rr/bdrm) I ZS - System type -Tee C ti
jwrr
Length S Width 3 Gravel thidmeas below pipe Y' Total depth 9
Effxtive absorption area '/S6 O' MOWtDnng Tube present(Y/N) 1 Depression over field (Y" IV
Date of adequacy test I Z / 12 / 96 Results (Pass/Fad) f:; -t; / For 3 bedrooms
Fhdd depth in absorption field before test (im.); CJ lm wftt b aflerAKZ gal. water added (in.): ��_
Fluid depth Kr ins.) Minutes later: 123 Absorption rate - < 'f S0 a P-4.
Peroxide treatment (past 12 months) (Y" Nooe kvw~ V yes, give dato N •.4.
ado rre bAq M a Sarchan�caoC Gc,n ori>4an - Mee e1- is %t tq+rra o&w(
,er � 1,4wche� d ��0D.
D. LIFT STATION
N. A.
Sia in gallons
Manhole/Access (Y/N) "Pump on" level at* "Pump otf' level at*
High water alarm level at* *Datum
Cycles tested
fw SEPARATION DISTANCES
SEPARATION DISTANCES FROM WELL ON IAT TO:
Septidholding tank on lot 1/0' : On adjacent lots > too '
Absorption Recd on tot 1 ZO , : On adjacent lots > 1&0'
Public sever main N. A. Public sewer manhole/deanaa N. 14.
Sewer /septic service line > Zs-' Lin •nation N..) .
SEPARATION DISTANCES FROM SEP710HOLDING TANK ON LOT TO:
Building foundation 10 ' property line 25 - Absorption Reid 5
Water mainhwvice line > to • Surfacewater/drainage > 1&0' Wella on adjacent tots > / CiO '
SEPARATION DISTANCE FROM ABSORP71ON FIELD ON LOT TO:
Building foundation 2,q'' Property Line —Lo --Waw main/service line > 10
Surface water > too ' Driveway, parlong/vebiele storage axes S
Curtain drain AI one S e eo Wells on adjacent lots > t ao
F. ENGINEER'S CERTIFICATION
I eerdfy that I have determined thra fteld inspections and review ofMrmidpat records l haus gWreiu
in conformance with MOA HAA guideNnea in effect an this date. "ti', •
49
Signature /jam '
Engianeer'sName TAto�O�e F. Muo� I • !•" tir�r,:•'.+:
i CE - 3 id9 •" ,tr i
Date Jeenuary Z9 1997
HAA Fee S 3 00 -ft
Date of Payment I
Receipt Numbs
Rev. 8/95 OSS: haa.wk.doc
Waiver Fee $
Date of Payment
Receipt Number
MUNICIPALITY OF ANCHORAGE
• DEPARTMENT OF HEALTH & HUMAN SERVICES
Division of Environmental Services
On -Site Services Section
P.O. Box 196650 Anchorage, Alaska 99519-6650
343-4744
CERTIFICATE OF HEALTH AUTHORITY
APPROVAL FOR A SINGLE FAMILY DWELLING
Parcel l.D. # (l 111- L\� a - �� NAA # 1A Q0 \ 0 1-16
1. GENERAL INFORMATION
Complete legal description Lot 4 • Deta Subd.Lvi4ion;
2.
3.
4.
Location (site address or directions) 6200 Eab# 112th. Avenue
Property owner ALASKA PF HANENT FUND Day phone
Mailing address
Lending agency G M A C Day phone
Mailing address
Agent Datlone ALL STAR REALTY Day phone 561-7821
Address 2 FnAt Trtrfn4 Road nchoXa9e,_Ata6lzo.-QQS07
Unless otherwise requested, HAA will be held for pickup.
NUMBER OF BEDROOMS:
TYPE OF WATER SUPPLY:
Individual well
Community well
Public water
3
XX
NOTE: If community well system, provide written confirmation from State ADEC attest-
ing to the legality and status of system.
TYPE OF WASTEWATER DISPOSAL:
Individual on-site XX
Holding tank
Community on-site
Public sewer
NOTE: If community wastewater system, provide written confirmation from State ADEC
attesting to the legality and status of system.
72-02S (Aw. 1/91) Front MOA 621
S. STATEMENT OF INSPECTION BY ENGINEER
As certified by my seal affixed hereto and as of the validation date shown below, I verify that my
Investigation of this Health Authority Approval application shows that the on-site water supply
and/or wastewater disposal system is safe, functional and adequate for the number of bedrooms
and type of structure indicated herein. I furtherverify that based on the information obtained from
the Municipality of Anchorage files and from my investigation and inspection, the on-site water
supply and/or wastewater disposal system is in compliance with all Municipal and State codes,
ordinances, and regulations in effect on the date of this inspection.
Name of FirmPhone —�`?
L1 ..4SG:.uY
Address ME RivarLook Road tJo.20q
. -:a Rivcr, as a ai
Engineer's signature
6. DHHS SIGNATURE
Approved for T/jO 3 bedrooms.
22
Date
• • - A- SNttx•- • r'
i117•P. r
Disapproved.
Conditional approval for bedrooms, with the following stipulations:
Additional Comments
«... C Date 6—/7-9/
The Municipality of Anchorage Department of Health and Human Services (DHHS) Issues Health Authority
Approval Certificates based only upon the representations given in paragraph 5 above by an independent
professional engineer registered in the State of Alaska. The DHHS does this as a courtesy to purchasers of homes
and thei r lending institutions in order to satisfy certain federal and state requirements. Employees of DHHS do not
conduct Inspections or analyze data before a certificate is issued. The Municipality of Anchorage is not
responsible for errors or omissions in the professional engineer's work.
72425(RWAA1) e.x MOAm
Municipality of Anchorage
Department of Health & Human Services
HEALTH AUTHORITY APPROVAL CHECKLIST
Legal Description: R%� Lk C)10 S SSS Parcel I.D.
A. WELL DATA
Well type.' If A, B, or C, attach ADEC letter. ADEC water system number }}..
Log present (Y/N) A% Date completed A)A.) -Nec. 1962 Driller f UiIV L sl[sl
_
Total depth I �� Cased to / 5 e Casing height / ;L
Sanitary seal (Y/N) 4 Wires properly protected (Y/N)
Date of test
Static water level
Well flow
Pump level J •
FROM WELL LOG
10 g.p.m.
SEPARATION DISTANCES FROM WELL TO:
AT INSPECTION fN�lq
MAV 141991
Septic/holding tank on lot (I S /
; On adjacent lots no �t
Absorption field on lot 2 I
; On adjacent lots / 00 f
Public sewer main N
Public sewer manhole/cleanout did
Public sewerservice line �/lA
Petroleum tank &)oNa Know nl
WATER SAMPLE RESULTS:
Coliform Sa f6'.1-/tH �Nitrate �Other bacteria J t�.lrn
Date of sample: Collected by: t n)G rA) F.C_d'J J
B. SEPTIC/HOLDING TANK DATA
Date installed If) f 3- O Tank size _ ICOO Compartments 2
Cleanouts (Y/N) T Foundation cleanout (Y/N) Depression (Y/N) hi
High water alarm (Y/N) IA `LII Alarm tested (Y/N) AYA �`
Date of pumping -12 '!' D I�OUSe A n !E> `eMr l l4 _f12.DA1 CIAfe o/ n
10U""P/N9 x"40011�-
SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK TO:
1 I •D
Well(s)onlot f I `-a Onadjacentlots I -Foundation
Topropertyline Absorptionfield 5 Water main/service line SS
i
Surface water/drainage / cc)-
724M(Aw. 191) F=1 MOA 21 CONTINUED ON BACK PAGE
C. LIFT STATION
Date Installed
Size in gallons
Manufacturer _
��— Manhole/Access (Y/N)
Vent (Y/N) "Pump on vel vel at
High water alarm level
Meets MOA electrical codes (Y/N) I v s
SEPARATION DISTANCE FROM LIFT STATION TO:
Well on lot On adjacent lots —
"Pump off" level at
Cycles tested
Surface water
D. ABSORPTION FIELD DATA
Date installed lo- f 3 -69 Soil rating Z — � System type I XX?PJCJA
Length / Width ,
Gravel thickness Total depth �
A
Total absorption area h Cleanouts present (Y/f.4) U
Depression'over field (Y/N) - Ai Date of adequacy test 3 b
Results (pass/fail) D i4 S S for 3 bedrooms
Peroxide treatment (Past 12 months) (Y/N) N/A If yes, give date I
SEPARATION DISTANCE FROM ABSORPTION FIELD TO:
Well on lot - (Z P On adjacent lots ( no 't Property line 7-2—
To
2To building foundation 7 o To existing or abandoned system on lot 0/14
Onadjacentlots �� it Cutbank��Watermain/service line (ED r�
i r
Surface water _too 'f Driveway, parking/vehicle storage area �(
Curtain drain AJ /b4
E. ENGINEER'S CERTIFICATION
I certify that I have checked, verified, or conformed to all MOA and HAA guidelines in effect on
5 E 5 ENGINE!ZR:NG
17034 Eagla River Loop Road No, 204
Eagle River, Alaska 99:577
Signature
Engineer's Name
Date
HAA Fee $ _
Date of Payment a — I tt`c%
Receipt Number
72-M(Rw. 3/91) Back MOA 21 bSX02 X01
Waiver Fee: $
Date of Payment
Receipt Number
e.date of this inspection.
No. 1157
p MUNICIPALITY OF ANCHORAGE lie4
•t Department of Health & Human Services p�
C•, DIVISION OF ENVIRONMENTAL SERVICES
343-4744
CERTIFICATE OF INSPECTION FOR HEALTH AUTHORITY APPROVAL OF
ON-SITE SEWER AND WATER FACILITY FOR SINGLE FAMILY DWELLING
Parcel l.D. # 01"�,— Lim - f1i HAA # 1-\ 12�qry-,114
1. GENERAL INFORMATION (Must be completed prior to submittal)
(a) Legal Description (include lot, block, subdivision, section, township, range)
Lot 4; 01�; De.0 Subdiv.iaion;
Location (address or directions)
6200 East 112th Avenue
(b) Property owner Ar RFRHANFUT Ft1ND Telephone : (home) Business
Mailing Address
(c) Lending Institution
Mailing Address
Telephone
(d) Real Estate Company and Agent AFISTAR REALTV ATT11• Pat Johnson
Address 2207 East Tudoa Road Suite #33 An6Fokage,, AeaAha 99507
Telephone
(e) Mail the HAA to the following address: (or check here rbc if hold for pick up.)
List contact person and day phone number below:
S & S ENGINEERING
17034 Eanle River Loop Road No. 204
Eagle River, Alaska 99577
2. TYPE OF RESIDENCE
Single -Family OX Number of bedrooms 3
3. WATER SUPPLY
Individual Well CRX Community ❑ Public ❑
Note: If community well system, must have written confirmation from the State Department of Environmental
Conservation attesting to th legality and status.
4. SEWAGE DISPOSAL
On-site I%X Public ❑ Community ❑ Holding Tank ❑
Note: If community well system, must have written confirmation from the State Department of Environmental
Conservation attesting to the legality and status.
72.025 (Rev. 7/881 Page 1 of 2
Z;o Z a6ed
4"S (BOIL -»e)szo-zL
'>IJom s,iaaul6ua leuo!ssa;ad eyl ui
suo!ss!wojosjajajo;alglsuodsailou sio6ejogouy;oLl!led!o!unlnlayl'panss!s!aleo!;!ljaoeejo;agelepaz lLuejo
suo!loodsul lonpuoolou opSHHO;O SOaAoldw3'sluawailnbaj elels pue lejapa; u!etjooAls!lesoljapio u! suo!lnl!lsu!
6u!pual i!ayl pup sawoy;o siasegand o1 Asalinoo a se s!yl saop SHHO ayl'elsely;o a1e1S ay1 u! paIals16aJ
Jaau16ua leuo!ssa;ojd luapuadapul ue Aq anoge S ydei6ejed u1 u9A16 suolleluasajdaj ayl uodn 6luo paseq paleo!;!iao
lenwddV Aj!jo41ny Ll11eaH sanssi (SHHO) sooimeS uewnH Pup g11eaH;o luawuedaO a6ejo4ouy;o Pled!o!uny4 ayl
IeuollipuoO
:? � il•LTI '�N
n 1gsiS 'Y V^S'r
............J.�.�
�wir"y
lenaddy leuo!1!puoO;o swial
panoiddes!O Y panaddy
Aq swoolpa,y,/uo; panaddy
1VAOaddV SHHO '9
LL966 e)lseltlJQAI-d UJOU3 ssaippV
POZ'ON Peob dool joAlll 016e3 V£OLL
6G Z 746 f auoydalal CNI2133NIJN3 w1!d10eweN
'uo!loodsui s!yl;o alep ayl uo loa;;a u! suo!leln6ai pup 'saoueu!pio'sopoo elelS
pup IediownIN Ile ql!m eouelldwoo ut s! wags (s lesods!p jalemalsem jo/pue Alddns jalem al!s-uo ayl 'uogoadsui
Pup u011e611Sanu! Aw wa; pup sal!; a6eioyouy;o 41!led!o!unW eyl woj; pau!elgo uo!1ewjo;ul eyl uo paseq
leyl A;!JOA jayUnl 1 'u!ajaq paleo1pu! amlonuls;o edAj pup swoojpaq;o jagwnu ag1 jo; alenbape put leuo!loun;
'ales s! walsAs Iesods!p Jalemalsem jo/pue Alddns jalem ells-uo 6y1 1et11 smogs lenoiddy L(1!jotllny ylleaH
.slyl;o uo11e611S8nu! Rw legl Aj!19A I'molaq umogs alep uo!lep!IeA eyl to se Pup olaJay paxy;e leas Ltw Aq pa!;!Uao sy
NOI1VWaOdNI CNV V.LVC'H0aV3S 311d'S1S31'SNOl1O3dSNl ONIC1AOad Wald ONIa33NION3 'S
MUNICIPALITY OF ANCHORAGE (MOA)
NICIPALIT'yc�jl q,(K�ty Approval (HAA) r0 /S-- 4/9� - 40
• IMBRUARY 1984
IROtiMENTAL 3.4744
MAR 2 71990
A.WELL DATA RECEIVED
Legal Description:u"L 4j 6- L -1i
-bels 5.�.
Well Classification r nJy (e- P- L M'1. If A. B. C. D.E.C. Approved (Y/N) —(
Well Log Present (Y/N) N Date Completed f j Ulla- 14 RO Yield
(3-fb -90
Total Depth I Sf3 Cased to 1'S11)_ Depth of Grouting
Static Water Level Pump Set At U K�
Casing Height Above Ground 1 r 1t Sanitary Seal on Casing (Y/N) y
Electrical Wiring in Conduit (Y/N) �i Depression Around Wellhead (Y/N) IJ
SEPARATION DISTANCES FROM WELL:
To Septic/Holding Tank on Lot 11!5 ; On Adjoining Lots t70 f
To Nearest Edge of Absorption Field on Lot / ; On Adjoining Lots / o
To Nearest Public Sewer Line/i/T To Nearest Public Sewer Cleanout/Manhole l4
To Nearest Sewer Service Line on Lot -z 5 'f
Water Sample Collected by 646 �w14 jAINtt� ; Date
Water Sample Test Results 1 vic- I u7 `1 _
Comments
B. SEPTIC/HOLDING TANK DATA
Date Installed 10-13-80 Size 1000 No. of Compartments
Standpipes (Y/N) 4 Air -tight Caps (Y/N) L( Foundation Cleanout (Y/N)
Depression over Tank (Y/N) A) Date Last Pumped 3 _ / 2 — `/ D
Pumping/Maintenance Contact on File (Y/N)NIA : for ���
Holding Tank High -Water Alarm (Y/N) A) Temporary Holding Tank Permit (Y/N) A rt—
SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK:
To Water -Supply Well I S r To Building Foundation 1
To Property Line 3U r To Disposal Field r
To Water Main/Service LineTo Stream, Pond, Lake or Major DrainageCoursel 00 t
Comments C4T1C. pt)M Ped t)`(
72-M IRw. 7/881 Fro -1 Page 1 of 2
C. ABSORPTION FIELD DATA
Soils Rating In Absorption Strata f 2 s am Type of System Design 77c! -A
Date Installed / 0/1�>/ eo Length of Field 6_7
Width of Field 3 Depth of Field 8
Gravel Bed Thickness
Square Feet of Absortion Area Statndpipes Present (Y/N)
Depression over Field (Y/N) Date of Last Adequacy Test
Results of Last Adequacy Test Sa4!Gro
SEPARATION DISTANCE FROM ABSORPTION FIELD:
To Water -Supply Well f :;,-a / , To Property Line 72- 7
To Building Foundation .20 To Existing or Abandoned System on
Lot /J/14 ; On Adjoining Lots 3 O +
To Water Main/Service Line /o O f To Cutback (if present) x)14
To Stream, Pond, Lake, or Major Drainage Course co rIL
r
To Driveway, Parking Area, or Vehicle Storage Area eZ
Comments c�Z to �4>Ti�J6r
D. LIFT STATION
Date Installed
Size in Gallons
"Pump On" Level at
High Water Alarm Level at
Tested for
Meets MOA Electrical Codes (Y/N)
Comments
Dimensions
Manhole/Access (Y/N)
"Check Permitted Bedroom Rating Against HAA Request"
"Pump Off" Level at
Vent(Y/N)
Pumping Cycles during Adequacy Test.
I certify that 1 have checked, verified, or conformed to all MOA and HAA guidelines in effect on the date of this
Inspection.
Signed S & S ENGINEERING
17034 Eagle RiverLoop Road No. 204
Company—Eegle-Wver7-Ala�ka-89577
Date a—?-,—
MOA No. CF_ 90 —c90 ?
Receipt No. ��Z%c' 2
Date of Payment - 2
Amount: $ _ /'%D- ct)
72-M (Rev. ABB) Back
Receipt No.
Waiver Fee:
Date of Payment
Page 2 of 2
CHEMICAL & GEOLOGICAL LABORATORIES OF ALASKA, INC.
5633 8 STREET ANCHORAGE, ALASKA 99518 TELEPHONE (907) 562.2549
FEDERAL TAX ID N 92-0040440
ANALYSIS REPORT BI SAMPLE for Work Order 1 20446
Date Report Printed: MAR 20 90 t 10:14
Client Sample ID:L4. 11: DELS S/D
PWSID :UA
Collected MAR 16 90 1 16:20 hrs.
Recerred MAR 16 90 t 17:00 hrs.
Preserved with :AS REQUIRED
Analysis Completed :MAR 19 90
Laboratory Supervisor :STEPHEN C. LDE
Released By �(�f�si�'�,../ �j,
......................................................................
Special
Instruct:
Client Name S b S INCH
Client Acet SNSENCP
P.0./ NONE RECEIVED
Req t
Ordered By : ROBERT SHAFER
Send Reports to:
I)S 8 S ENCR,
2)
Chemlab Ref t: 900505 Lab Smpl ID: 1 Matrix: WATER
Allowable
Parameter Tested Result Units Method Limits
--------------------------------------------------------------------------------------------------------------
NITRATE-N NO(0.10) mg/l EPA 551.2 10
Sample ROUTINE SAMPLE
Remarks: SAMPLE COLLECTED BY R.D.J.
..............................................................................................................
1 Tests Performed See Special Instructions Abore Uk•Onarailable
N0• None Detected See Sample Remarks Abore
NA- Not Analyzed LT -Less Than, GI•Creater Than
..5,N54Fitr-7?
CHEMICAL R GEOLOGICAL LABORATORIES OF ALASKA, INC.
TELEPHONE (907) 5622343 5633 B Street
_ Anchorage. Alaska 9951E
Drinking Water Analysis Report for Total Coliform Bacteria
TO BE COMPLETED BY WATER SUPPLIER TO BE COMPLETED BY LABORATORY
❑ PUBLIC WATER SYSTEM LDA Analysis shows this Water SAMPLE to be:
A PRIVATE WATER SYSTEM
Satisfactory
Name Phone No. ❑ Unsatisfactory
S & S ENGINEERING ❑ Sample too long In transit; sample should
17034Y4o-Rtvertoapita3t1 9, not be over 30 hours old at examination
Mailing Address Eagle River, Alaska 99571, to Indicate reliable results. Please send
new sample via special delivery mail.
City
State
SAMPLE DATE: O 3 ® FEE
Mo. Day Year
SAMPLE TYPE:
Zip Code
❑ Routine
❑ Check Sample (for routine sample
with lab ref. no. 1 ❑ Treated Water
❑ Special Purpose ❑ Untreated Water
SAMPLE Time Collected
NO. LOCATION Collected By
L/
2 I I
3 1 1
4
5
Date Received .9 -46 -?o
Time Received / 70-D
Analytical Method: Membrane Filter
No. of colonies/100 ml.
Lab Ref. No. Result' Analyst
90 osa3 a ®_
U m
U m
U m
U m
BACTERIOLOGICAL WATER ANALYSIS RECORD /qV
Cy
READ INSTRUCTIONS Membrane Filter. Direct Count C�) Coliform/100mi
BEFORE Verification:
BGS
COLLECTING SAMPLE Final Membrane Filter Results Coliform/100mt
Reported B _Date
Time: /v, a.m.
p.m.
TNTC = Too Numberous To Count
I
PART ONE OF TWO
OB = Other Bacteria
MIAINMER TO FOLLOW
1.
MUNICIPALITY OF ANCHORAGE
DIVISION OF ENVIROt�NTAL HEALTH
DEPARTMENT OF HEALTH AND ENVIRONMENTAL PROTECTION
APPLICATION FOR HEALTH AUTHORITY APPROVAL CERTIFICATE
1. General Information
Application Date
_ 01 h< -
(a) Legal Description (include lot, block, subdivision, section, township, range)
Location (address or directions)
(b) Applicants Name Telephone - Rome Business----'
Applicants Addresses �'�= �/ U %%r✓l-?;nom, a� G�I,S�/
(c) Applicant is (check one) Lending Institution Owner/ wilder ;
Buyer ED ; Other [= (explain);
(d) Lending Institution �/ R/' Telephone
Address POU C ! %��J / /�/� ( 11 - �•5 ��
(e) Real Estate Co. S Agent
Address
Telephone
(f) Mail the HAA to.the following address:
2. Tvve of Residence
Single -Family
Number of Bedrooms
multi -Family
Other (describe)
3. Water Supply'
Individual Well Community Public
Note: If community well system, must have written confirmation from the State
Department of Environmental Conservation attesting to the legality and status.
4. Sewaee Disposal
Onsitel Public Q Community Holding Tank r_7
Note: If community well system, must have written confirmation from the State
Department of Environmental Conservation attesting to the legality and status.
[Page 1 of 21
Gi
Tests. Fil
.eool�
oartified by my seal affixed hereto and as of the validation date shown below, I
WArify that Ly investigation of this Health Authority Approval shows that the on-site
Ater supply and/or wastewater disposal system is safe, functional and adequate for
LW amber of bedrooms and type of structure indicated herein. I further verify that.
based on the information obtained from the Municipality of Anchorage files and from my
19vestigation and inspection, the on-site water supply and/or wastewater disposal
system is in compliance with all Municipal and State codes, ordinances, and regula-
tio^.s in effect on the date of this inspection.
Name of
Addres
Datez-
L�
(ENGINEER SEAL)
E. D�oval
Approved for bedrooms By
Approved Disapproved
Ter --s of Conditional Approval
:ai�r�iS�Zll
Conditional
Telephone / /- Li/' /(
C. Raid, Jr..
2251-B , •'� '
TF'r ,V;ICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH AND ENVIROlL`fENTAL pROTECTION
(DHEP) ISSUES IMNLTH AUTHORITY APPROVAL CERTIFICATES BASED SOLELY UPON TRE REPRESE%T-
ATIO!S GIVEN LH PARAGRAPH 5 ABOVE BY AN INDEPENDENT PROFESSIONAL ENGINEER REGISTERED
IN I= STATE OF ALASKA. THE DHEP DOES THIS AS A COURTESY TO PURCHASERS OF HO2 S AND
=IH LENDING INSTITUTIONS IN ORDER TO SATISFY CERTAIN FEDERAL AND STATE REQUIRE-
!! .:IS. EMPLOYEES OF DHEP DO TOT CONDUCT INSPECTIONS OR ANALYZE DATA BEFORE A
CEETIFICATE IS ISSUED. THE MUNICIPALITY OF ANCHORAGE IS NOT RESPONSIBLE FOR ERRORS
OR .jISSIONS IS TEE PROFESSIONAL ENGINEER'S FORK.
RR4/ej/D18
[Page 2 of 2]
(DHEP SEAL)
7-19-84
. .. MTAridPALRV OF ANCHORAGE
Of HEALTH 6
EMAROWENTAL PROTECTION
MUNICIPALITY OF ANCHORAGE (MOA)
HEALTH AUTHORITY APPROVAL (HAA)
✓�
RECEIVED CHECKLIST - FEBRUARY 1984
A. WELL D4TA Legal Description: L1/ 155
r -12-.A) 9 310 !:a -c R,3
Well Classification viva If A, B, or C, D.E.C. Approved(Y/N) 01,4
��
Well Log Present (YpTv/1 O Date Colleted Nov -Dec /4gp Yield
Total Depth 1 SFS' (D Cased to /50T Depth of Grouting .t/1,4 U
Static Water Level :;;_/.g{ dD Pump Set At
Casing Height Above Ground /..2.1 Sanitary Seal on Casing N)
Electrical Wiring ir. Conduit K'N) Depression Around Wellhead (Y
IO
Separation Distances from Wall:
To Septic/Holding Tank on Lot //,S "x`" On Adjoining Lots 7-100
To Nearest Edge of Absorption Field on Lot /Zlo On Adjoining Lots ,4-100
To Nearest Public Sewer Line ,t//4 To Nearest Public Sewer
Cleancut/Manhole To Nearest Sewer Service Line on Lot
Water Sample Sample Collected By 6bA_Date G/av'Aas
Water Sample Test Results �,4TySFACT -MV �! / /
Cavments ©%�.,��PM rm �wa w. 1A&;"kAo.J -u .1a"1 /1 � 4 . tY1 all4rka (V we" vq'�
B. SEPTIC/HOLDING TANK DATA
Date Installed Size 11W No. of CaTpartments 2—
Standpipes M) Air -tight Caps N) Foundation Clearout N)
Depression over Tank ( ) Date Last Pumped
Pumping/Maintenanoe Contract o1 File (Y/N) for
Holding Tank High -Water Alarm (YIN) Temporary Holding Tank Permit (YM)
Separation. Distances from Septic/Holding Tank:
To Water -Supply Wall 11S "'If— To Building Foundation /
To Property Line 3D To Disposal Field
To Water Main/Service Line sS� To Stream, Pond, Lake, or Major Drainage
[Page 1 of 21
Receipt # '� tl C1UO U
Date Paid: Q—(O-�64T-
Amount: w5-.00
2-15-84
l -q Dels
C. ABSORPTION FIELD DATA
Soils Rating in Absorption. Strata Type of System Design PELr-„l
Date Installed /Oft Length of Field S;./
Width of Field 3 Depth of Field
Gravel Bed Thickness
Square Feet of Absorption Area _ y$j, Dr Standpipes Present �ttJ)
Depression over Field (YA Date of Last Adequacy Test
Results of Last Adequacy Test pssea/ry-)— 3 Zpalpe"+s
Separation Distance from Absorption. Field:
To Water -Supply Well /a.0 To Property Lire ZZ�
To Building Foundation 2e , To Existing or Abandoned System on
Lot IV /4- ; On Adjoining Lots 74-.30 ice.
To Water Main/Service Lire f-&tj "A- To Cutbank(if present) N /'�L
To Stream/Pond/Lake/or Major Drainage Course -A/00 " )f -
To Driveway, Parking Area, orLI.. Vehicle/ Storage Area 9 '�+ /
Comments tib MAUACtrvv -4 Yui
D. LIFT STATION
Date Installed
Size in Gallons
"Pump On" Level'at _
High Water Alarm Level
Tested for
Electrical
Comments
Dimans ions
at
Vent (Y/N)
Cycles during Adequacy Test. Meets MOA
** Check Permitted Bedroom Rating Against HAA Request **
I certify that I have checked, verified, or oonfcrmed to all MDA HAA Guidelines in effect
on the date of this inspection.
Signed Date
Company MDA No. 5T Qel
KB1/d5/s up
1-6-06
(Page 2 of 21 Ll� cb
2-15-84
j1
ALASKA EI01ROfl nTAL C0nTROL SMICCS, InC.
Enginetrinq & Enuironmenial Studies
JULY 16 1985
BECKY AND AL HANNON SELLER—SAME BECKY AND AL HANNON
P.O. BOX 110473 P.O. BOX 110473
ANCHORAGE ALASKA ANCHORAGE ALASKA
99511 99511
50364
LEGAL:DELS SUBDIVISION IAT 4 BLACK 0
ADEQUACY TEST FOR SEWER SYSTEM
ADEQUACY TEST DATE—JUNE 27 1985
THE TYPE OF ABSORPTION SYSTEM IS A TRENCH WITH AN AREA OF 456 SQFT.
THE SYSTEM IS CAPABLE OF ACCEPTING 450 GALLONS OF WATER PER DAY.
THE SURGE CAPACITY OF THE SYSTEM IS 628 GALLONS.
BASED UPON THE TEST DATA THE SYSTEM IS ACCEPTABLE FOR A
3 BEDROOM HOME.
SEPTIC TANK ADEQUACY
THE EXISTING SEPTIC TANK VOLUME OF 1000 IS ADEQUATE FOR
THIS 3 BEDROOM HOUSE.
THE SEPTIC TANK/PACKAGE PLANT WAS PUMPED ON JULY 16 1985 .
FLOW TEST ON WELL
WELL FLOW DATE—W?Juhl`27, 1985
A FLOW TEST WAS PERFORMED ON THE WELL. 628 GALLONS OF WATER WAS
PUMPED AT A RATE OF 5.2 GPM OVER A DURATION OF 2 HOURS.
THE DRAWDOWN WAS 26 ' WITH A RECOVERY TIME OF 90 MINUTES
AND THE STATIC WATER LEVEL WAS 71.8 FEET.
THE WELL IS ADEQUATE FOR THIS 3 BEDROOM HOME.
OF Q — LO
t9in j
1
Lamy Ret.l, Jr.
22S1•E ,... v
1200 West 33rd Auenue. Suite B • Anehoroge. Alaska 995039(9071561-5040
Anchorage Well Pump Service
N
N
July 12, 1985
To Whom It May Concern:
eol�s.
6901 Tanalno Drive • Anchorage, Alaska
Anchorage Well Pump Service was involved in the
installation of a pump on Lot 4 Dell's Subdivision
in December 1980.
The subject well was originally drilled and cased
to a depth of 147' by Arvin Langston, and then later
drilled and cased to a depth of 158' by Jim Booze.
Anchorage Well Pump Service was involved prior to
the second drilling and are aware of the enclosed
Enclosure
• Domestic and Industrial Pump Sales and Service • Water Wen Service. Water Treatment and Conditioning
JUNE 27, 1985
TO WHOM IT MAY CONCERN:
I, THE UNDERSIGNED OWNERS OF HOUSE LOCATED AT LOT Q DEL'S S/D
DO HEREBY GUARANTEE THERE IS AT LEAST 158 FEET OF 611 WELL CASING
IN WELL ON SAID PROPERTY.
ate- Z' /
an W. Hannon
-�' Q. b"4tot
Becki A. Hannon
Q
my (ommbdon Expina
FaWuW V,1989
v
Il
�i / 1
5336 •C Street - 894-4661
January Y. 1996 Pile No.:., 4-1
Mr. Kan Del Monico
SF.A Boz 46
Anchorage. Alaska "901
SUPJSCT. $-SO" Del's S"rision
Dear Mr. Del Monteo:
On January 6. 1946 the Platting Authority approved the subdivision of your
land into tour lots. As a condition of Ming the final plat, you will need to
do the following:
1. Obtain a proper soil test an lot 1 in an ores. approxiasstely 100 feet
from the existing well, or any surrounding wells;
2. Obtain a permit for upgrading the sewer systems (the present system
is about 45 foot from the well.
3. Install a new system in conformity with the permit (atter break-up).
Due to winter weather, this department would be willing to great a waiver for
obtaining the soil test and permit providing you submit a legal document of
agreement for the upgrading of the sewer system as well as proof that funds
have been escrowed for the improvements. Upon receipt of time documents
we will notify this Planning Department that our oo ittiona have been met.
We would then eapeet the eampletion of items 1 through 3 as soon " weather
permitted.
Plea" notify this offies as soon as possible of your intent in regard to complying
.with the conditions on the plat.
If you
have any questins. pleasII O=taet ase at
194-4b61.
Sincerely,
RECEIPT FOR CERTIFIED MAIL --30¢ (plus postage
'? SPOSTMARK
SENT TO
OR D((ATTE
'
STREET AND N0.
1
_
/�Sarin E.JDlwalt
P.O.. STATE ANO IIP CODE
;zv
8enitarlan
M
�
•
V•-
OiT10K�1 fE6Vl C_[f 103 �ODIfiIOMAL I[[1_
SWAM3[{FRT
�
�}'
SETUSM 11 She. to Whom ie! dated
' wain de01"r to address only ..._...� 656
i.WAM .
�
1. tbo to Who gate end WNen 60111"116. 351
111 VICES W.Ih dehmy to Addressee only _.......... 65f
' .
DELIVEM TO AODR[SSFE ONLY ......................................... 30f
_ —
ee: Lee 3JuahAeis11 8anitarien
Q
- _ T (e.ere Iw rewired)—•--_..__......_...._......
SPECIAL OEUVER
•
eZ
PS Ferm 3800 NO INSURANCE COVERAGE PROVIDED— (See ash., aid.
Apr. 1971 NOT FOR INTERNATIONAL MAIL .OPo:E111 o -neo -T.
October 13. 197E
11111 Jones. Planning Department
Sm. for Environmental Specislist
5-3939 - Del's SubdtAtion
The conditions placed on the prellydnary plat for the sewer system upirrade
have been satisfied. Mr. Del Mouioo has c;reed to obtain final inspection
on bis sewer system upgrade by Juan 1, 1911. This department is
astisfied that all conditions have been mot.
Suesu E. Oswalt
Senior Environmental Specialist
SEO/iw
cc: ken Del Monleo
ftmicip"ty
Of
Anchorage
--
POUCH 6-650
ANCHORAGE, ALASKA 99502
(907) 279-2511
GEORGE M. SULLIVAN,
MAYOR
DEPARTMENT OF HEALTH AND ENVIRONMENTAL PROTECTION
(625 "L" Stmet)
May 12, 1977
TO: Whom It May Concern
SUBJECT: On-site Sewer Dells Subdivision
The requirements for sewer system upgrade on Lot 1
Del's Subdivision have been met and the system is
approved as meeting the minimum requirements of this
department.
On-site sewer permit #76542 issued by this office on
July 20, 1976 by R. Strickland has been modified to
allow the utilization of a..septic tank.
If there are any further questions, please contact
this office at 279-2511, extension 224 or 225.
Sincerely,
�C/
_kI
0 s S. Blair, R.S.
nvironmental Services Manager
JSB/ljh
cc: Ken Del Monico
Star Route A Box 26
Anchorage, Alaska 99507
By .................................DATE
CHKD. BY ................ DATE
SUBJEC:................................. _.... ............................. __................... ^.SSHEET NO. .................. OF.................
F..
.............................................. JOB NO. ......... _....................................
i vi.J•i o a
p6`/
Gev.:e y
I CoQ PJG i F o
,lo 71
fAlfz
DEP?F*TMENT OF ENVIRONMENTAL QUA^TY
PLATTING OR PLANNING & ZONINC CASE REVIEW
CASE NO.
TITLE: oQt�a S�O
Date Case Received BY
Suspense Date Comments to Planning Department /z For Planning & Zoning Commission Meeting Date
ROUTING
Environmental Engineering
Air Pollution
Noise 1 ��
Environmental Sanitation
8y'
J
COM14ENTS: _ �,{ 0/'—'
6
1• h
0
November 29, 1975
Paul G. Hansen, P.E.
2526 East 88th Avenue
Anchorage, Alaska 99507
Mr. Ken Del Monico
Star Route "A" Box 26
Anchorage, Alaska 99507
SOILS EXPLORATION AND PERCOLATION TESTS
PROPOSED DEL'S SUBDIVISION, LOTS 2, 3, 4
NEAR W HALLEY SCHOOL, ANCHORAGE, ALASKA
In accordance with your request, soils exploration and percolation testing
for on-site sewage disposal were performed on the three proposed lots.
Drilling was performed on October 6, 1975 by Denali Drilling, Inc. of
Anchorage employing a B-50 Mobile drill and consisted of three 20 -ft.
test holes; logging and percolation testing were performed by myself
in accordance with the United Soil Classification System, the Soil Triangle,
and the "Manual of Septic -Tank Practice". Soils were described and classified
in the field by means of numerous grab samples.
Logs of test holes are found on Sheet 1; percolation test results are
on Sheets 2 and 3. Test hole locations have been plotted on your proposed
subd0ision plat.
The property has very satisfactory drainage to the northwest, with a
maximum relief of about 60 feet throughout the three lots. No standing
water was noted. Numerous large spruce and birch trees, up to 15 inches
in diameter, were observed.
In general, the soils consisted of sand, silty sand, sandy silt, and
gravelly sandy silt (SP, SM, ML) of medium density. Gravel and small
cobbles were occasionally encountered. A water table was encountered
in Test Hole G3 (Lot 4) only, at a dept o eet. For this reason,
no percolation tes wa-s per orme in 1.11. 3; however, if necessary, an
on-site sewage disposal system could be located in the southern half
of Lot 4, at a higher elevation, where the water table is expected to
be at a greater depth. T.H. 2 started to slough during the percolation
test, giving erratic results, so another test was performed in an adjacent
test hole (2A) with a standpipe. Test holes were filled with water and
saturated for at least 24 hours prior.to percolation testing. The two
percolation tests yielded percolation rates of about 9 minutes '
3-1/2 to 4 hours after the tests began, corresponding o about
square
feet of absorption area required per bedroom. The test hole logs would
suggest a value of about 200 square feet.
S3929 -JA" 1F16
mr. Ken Del Monico
t:ovember 29, 1975
Page 2
In my opinion, the three lots appear satisfactory for the proposed
development, in terms of surface drainage, foundation soils, and on-
site sewage disposal.
OF A4
w p�yPr•''�':.fy0
PAUL G. HANSEN* P.E. ,r TH V • «gyp
PGH: sh......... ..Y� ••o
' P%VLG ul�srr
Enclosures + y"•. 3710
oa041 /ONAL E� 1
9 2 1AfJ 6 1971G
PC- RCOLATIOrJ Tcsrs
l � Hole I DI��II}eJ{ p/cfoGu 4,,})M to 20'
- DSGlvff.l,o�--d G.1.7/�5.y ry ,
. Percoj, 1, ln� (f'S'�' /'V!1 (NI 0, t,, be, Y,�S
TMe
Tt�ne 46,,, S rwr
/ ri
Aew , A;f
6:35 Pro.
slewr
5"
63 PMS
�.27 Ph
52 r.,,,,,,7er
/' �"
1"2"= 14 •'
35 .P14
.3 hr.
3� Z,,
33"
/0: /S P/1
3 Ar 90.,
73
31.i
T
14o le Z(ZA) O(�n,/i1eif O/cf6e�r.� 6(, _i5 to 7-0'
J4 ,Zt�e.O O -/d Ger /7- 16, !J
PercoU,rm r,/r, on Oc-t %, 1f%S
P '
T,rNP �ro,,, StGrt
/ ri
Dell,
63 PMS
37 ✓n,il r„r
6' l"
�� •,
73
73
31.i
� n�Y
Ynet /
n
Test Hole 1
TEST HOLE LOGS
Location: Lot 2
Elevation: 6841
Water Table While Drilling - None
Water Table 24 Hours After Drilling - None
Depth Description
0 to 6" Brown Organic Cover
6" to 4' Brown. SP Sand Gravel, GM
4' to 12' Brown, NFS, dry to damp, fine to medium Sand, SP
with frequent gravel and cobbles, (maximum size 4")
12' to 20' Brown, F2, moist Silt Sand, SM (possibly ML),
with random fine gravel
Test Hole 2
Location: Lot 3
Elevation: 6801
Water Table While Drilling - None
Water Table 24 Hours After Drilling - None
Depth Description
0 to 6" Brown Organic Cone
6" to 3' Brown, moist, F2Silt Sand, SM
3' to 6' Brown, moist, F4 SaM Silt, ML
6' to 20'- Brown, moist -damp, F2, Nonp astic Silt
y Sand, SM
with random fine to medium Gravel P 8 , TOT; and 13-1/2 - 14'.
Test Hole 3
Location: Lot 4
Elevation: 662±
Water Table While Drilling - 12'?
Water Table 60 Hours After Drilling - 11'
Depth
Description
0 to 4"
Brown
Organic Cover
4" to 2'
Brown,
F4,
�•iet, nonplastic fineSandy Silt, VL
2' to 4'
Brown,
F4,
Gravelly Sandy Silt, ML, Maximum Size - 1-1/2"
4' to 7-1/2
Brown,
F2,
moist Silty fine Sand with random fine gravel, SM
7-1/2' to 12'
Brom,
F2,
moist fine - Ftedium Sand, SM, possibly SP
12' to 15'
Brown,
F2,
_Si
wet Si tyl Sand, SMwith ram fine gravel maximum
size -
1/2"
15' to 20'
Brown,
F4,
wet Gravelly Sandy Silt, ML with 10 to 20% Gravel
S 2 a JAS,
:9 6 1976
ko
70
REP
20
,e
,S%ee't3
�c=R��LAT I O N T;
. {rvrn iii to Q lrn.rt
PC -r -() Ie un �2G`fe
7rorbl 3k,
�''��,:� :rte• T �:'i
,r
,S%ee't3
�c=R��LAT I O N T;
. {rvrn iii to Q lrn.rt
PC -r -() Ie un �2G`fe
7rorbl 3k,
�''��,:� :rte• T �:'i
n
STATEMENT OF QUALIFICATION
PAUL G. HANSEN, P.E.
n
EDUCATION: Geological Engineer (Geol.E.), Colorado School of Mines, 1968
MSE, Soil Engineering, Princeton University, 1969
Doctoral work, 1970
EXPERIENCE: Soil Mechanics & Foundation Engineering, Alaska Testlab
(ACLW, later DOWL Engineers) 1970 - 1974
REGISTRATION: Civil Engineer 3710-E, State of Alaska