HomeMy WebLinkAboutT15N R1W SEC 5 LT 8T15N R1W SEC 5
SM
LOT 8
051-032-01
EXPIRED PERMIT
Mayor Mark Begich
Municipality of Anchoragc
Department
December 6, 2007
Frank Melke
PO BOX 670287
Chugiak, AK 99567
Subject: NOTICE OF VIOLATION
T15NR1WSEC 5 SM LOT8
On-Site Water & Wastewater Permit (s,~)60139)
Certified Mail #:70042510000198885206
Dear Frank Melke:
The final inspection report for your wastewater system has not been received by the On-
Site Water and Wastewater Program office. This letter will serve as a Notice of Violation
that there is an unapproved water and/or wastewater system at this location. Anchorage
Municipal Code requires:
· Within 30 working days from the date of the final inspection of an on-site
wastewater disposal system, an inspection report, shall be submitted to the
department by the owner or his agent. The report must bear the seal of an
engineer and be on a form and to standards prescribed by the department.
· No person may cause or permit any wastewater to be discharged or disposed of
except into an on-site wastewater disposal system conforming to state and
municipal standards.
In order to avoid future enforcement actions, which may include fines, please contact
your engineer to resolve this violation. An inspection report for the subject wastewater
system must be received by this office ~fithin two weeks ofthe date on this letter.
Thank you for your cooperation in this mat~er. Please call the On-Site Water and
Wastewater Program at 343-7904 if you have any questions.
Sincerely,
Jeff Poet
Engineering Technician
On-Site Water & Wastewater Program
Community, Security, Prosperity
~ PO BOX 670287
Chugiak, AK 99567
Wockenfuss, Deborah M.
From:
Sent:
To:
Subject:
Moeller, Laura Jo
Wednesday, April 30, 2008 1:45 PM
Wockenfuss, Deborah M.
RE: Mielke Status
Right of Way section says MOA has jurisdiction.
Refer any questions to Larry Ison or Tom Knox (because I sure as heck can't explain it).
Are you back at your desk? I took this paperwork over to you, but you had stepped away.
From: Wockenfuss, Deborah M.
Sent: Monday, April 14, 2008 8:22 AM
To: Moeller, Laura
Subject: RE: Mielke Status
Thank you,
Deb Wockenfuss
Onsite Water/Wastewater Department
Municipality of Anchorage
343-7906
From: Moeller, Laura .lo
Sent: Friday, April 11, 2008 3:13 plVl
To: Wockenfuss, Deborah M.
Subject: rvlielke Status
Hi Debbie!
Vicki Gerken and Tom Knox are helping determining MOA interest in the BLM Patented ROW along
the north side of the Mielke lot. Some of the documentation provided to me by Mielke is irrelevant,
but they need to look more into the Small Tracts deal.
It is taking some time to do the research, and Tom is going on vacation tonigh, but meanwhile, if you
have questions re the status, please contact Vicki Gerken.
Municipality of Anchorage
Development Services Department
Building Safely Division
On-Site Water and Wastewater Program
4700 South Bragaw St.
P.O. Box 196650 Anchorage, AK 99519-6650
wv~v. munLorg/onsite
(907) 343-7904
ON-SITE SEWER/VVELL SUBMITTAL COMMENT SHEET
To: Bob
Legal description: _'I'15N RIW ,5~ctlon 5 Lot R
The attached paperwork has been reviewed and is being returned for the following reasons:
Original signature or stamp missing on
Calculation error in design..
Additional soils information needed.
Water monitoring results inadequate. ,,
Discrepancy in information submitted.
Topographic information missing or inadequate.
Incomplete; missing ~Dl~ovel f~m Right of Way Department fro' trench in easement,
Incomplete; missing.
Additional adequacy test information needed.
Water sample unacceptable..
Measured/proposed distances/dimensions missing.
Locations of all soils, percolation and water monitoring tests not shown..
Proposed system too deep for soils information submitted..
Well log required.,
Omission in narrative.
Insufficient fill over tank or field.
Other.
Name of reviewer: 3'eff Date: .12-22-O6
Please supply the necessary information and re-submit your request.
LEA VE THIS FORM ATTACHED TO THE PAPERWORK
O
Municipality of Anchorage
Development Services Department
Building Safety Division
On-Site Water and Wastewater Program, 4700 Bragaw St.
P.O. Box 196650 Anchorage, AK 99519-6650 Page ~ of~,'
www.ci.anchorage.ak.us (907) 343-7904
ON-SITE WASTEWATER DISPOSAL SYSTEM AND/OR WELL INSPECTION REPORT
Permit Number: ~ [.'~,,q~ C) ~ 0' i '~ ~' PID Number:
Name:
~¢~*q~ ~l ~ WastewaterSystem: ~ New ~Upgrade
'"" ' q~S-~'7 ABSORPTION FIELD
Phone: /~~ ?'7~~ Number Deep Trench ~Shallow Trench ~Bed ~Mound
Soil Rating: Total Depth from original grade: ~ Ft.
LEGAL DESCRIPTION J, ~
Block: Lot: ~ Subdivision: Depth to pipe bottom fro~ original grade:~ Gravel depth beneath pipe:
Tow,~hi~: ~? Rano.: ~ L.~) S~ot,on:~ "i"~dd~d~v~°~i*a'~'~d~--3¢ I ~'. ~,~w,~.¢h: :~ ,t.
Well: ~ New ~ Upgrade G~aw~ w~dth: ~~t. N~m~e~,~of ~i~e~: D~st~*o~ ~t~en~ ~in~:~t.
C,Bssifioation (~,ivate, A. ,~): , ; Total Depth: Cased to: Total absorption area: ('/10 P,e M~teria,:
Dril~__.~ Date D[,,~: Static Water Level: Instafler: Date Installed:
Yield: ............... [~mp Set at: Casing ~e~~d: ~ ~ O~ ~
~' ............ GPM/ Ft. ~Ft. TANK
SEPARATION DISTANCES ~Semio D Holdi~ D S.T.E.P.
Tank Field Station Tank Sewer Line ~ ~-~ I~:, ~
~! ~% ~ ~ Material:
Well i¢~i j ~.} ~ ~ I I / ~.. ~ P¢¢ Number°fC°mpadments:
Lot Line Manufact .....
Cu~ainDrain '- -- ~?'~''~* ~O'2:~1~ ~'t~*~j~r~-~umpMake&MOde, Electrioallnspectionspedormedby:~X
! - Location and Description:
Inspections performed by:lT~E~leRiv~L~R~d, Ne'g~s' 1~t g-/ '/-L~
Development Se~ice~ B~nndment Approval
Conditional Approval ~ O ¢ Date:
~,~i,~Ted and approvec Date:
PERMIT NO. SW060139 PAGE 2 OF 4
Hunicip, aLi-t;v o¢' Anchoro, ae
DEPARTMENT OF HEALTH AND HUH'AN SERVICES
ENVIRONMENTAL $ERVlCE$ DIVI$10N
P,D, Box 196650 eAnchorage, ALaska 99519-6650 e TeLephone: 343-4744
ON-SITE WASTEWATER DISPOSAL SYSTEM AND/OR WELL INSPECTION REPORT
r.EGA~. LOT 8, SECTION 5, T15N, RlW P.I.D. NO. 051--032--01
CONLEY AVENUE
(NOT CONSTRUCTED)
ENg~STAUP
717: -
I
PERMIT NO, SW060139 PAGE 3 OF 4-
Plunici~Li~y oF Anc½omaQe
DEPARTiVlENT OF HEALTH AND HUIVTAN SERVICES
ENVIRONMENTAL SERVICES DIVISION
P,EI, ]}ox 196650 e Anchomage, A(~sk~ 99519-6650 ® TeLephone', 343-4744
ON-SITE WASTEWATER DISPOSAL SYSTEN AND/OR WELL INSPECTION
REPORT
LEGAL LOT 8, SECTION 5, T15N, RlW P.I.D. NO. 051--0,.52--01
MT1
TRENCHES
CONLEY AVENUE
(NOT CONSTRUCTED)
gI
TH MT4
TMT
] 300 GALLON
f HDPE SEPTIC TANK
MT2
ST2
iNSU LATED~NN~
UNDER ~.
D R~V~co ~ EWAY
'~ ~gS,~oo,'
~0'
'~'~ - I ENGINEER STAMP-:
~Oo, ' .c~~
~1 ?'..:' ~' -N¢~
PERMIT NO SW060139 PAGE 3 OF 3
Municip, o,(i-i:...¥_..oF Anchor'a(:e
DEPARTMENT OF HEA~LTHAND HUMAN SERVICES
ENVIRONMENTAL SERVICES DIVISION
P,O, ]3ox 196650 ·Anchorage, Alaska 99519-6650·TeLephone: 343-4744
ON-SITE WASTEWATER DISPOSAL SYSTEM AND/OR WELL INSPECTION REPORT
LEGAL LOT 8, SECTION 5, T15N, RlW
P.I.D. NO. 051-032-01
FINAL GRADE--N ST1 ST2 C01
MT2
100 7'~MT1 [-] [] , , MT3n n MT4
' kll 11/--101.4 101.5-x II II 101
........... 1.1 ........... 1}.... II 1i
,'~:'.:,i:i:'! S A N D (i;!i,~:f'
- 997 MT2 - ga a' i 8'
MT1 - - ....... - .... / ~,.;~,~q x_ MT4 98.
MT3 -- 98.7' ~'
A B
ST1 14.5' 21.0'
ST2 12.5' 24.0'
TMT 1,.5.0' 26.5'
CO 12.0' 26.5'
MH 12.0' 28.5'
MT1 82.0' 88.5'
MT2 24.5' 4,5.0'
MT,.5 80.0' 81.0'
MT4 22.5' 50.0'
·
WATER FOUND ® 88.2'
86.7' B.O.H.
N. T. S.
EN(
STAMP
METRO ELECTRIC,, INC.
ELECTRICAL CONTRACTING
P.O. BOX 671189. CHUGIAK · ALASKA 99567
PHONE (907) 277-1392 · FAX (907) 274-4705
DATE: INVOICE NO.
July 12, 2006 2686
A-I-rENTION:
Frank Mielke
TO:
Frank Mielke
Chugiak, AK 99567
REFERENCE:
Kurt Koehler
Instil ~er furnished ~uipment or ~er I~ ~taflon. Provide ~m and
mi~eflan~us ele~ical items.
210' ~12 THHN s~n~ wire ~s.2~ $ 55.91
280' ~18 THHN s~id ~re ~ 14.74~ 32.12
I lot misc wire n~, ~ ~, etc. 2.00
6 Houm labor et~dans 70.O0thr 420,00
NO~: nl mate,als ~ ~ui~'fi~;~~~~and I~1
~0~. We have ~ ~a~:~~~~~h~ materials
MUNICIPALIT~ OF ANCHORAGE
Development Services Department
On-Site Water & Wastewater Program
4700 South Bragaw Street
P.O. Box 196650, Anchorage, AK 99519-6650
(907) 343-7904
ON-SITE WASTEWATER DISPOSAL SYSTEM PERMIT
Upgrade
Date Issued: Jun 07, 2006
Expiration Date: Jun 07, 2007
Permit Number: SW060139
Legal Description: T15N R1W SEC 5 SM LOT 8
Design Engineer: 0003 S & S Engineering
Owner Name: FRANK MELKE
Owner Address: PO BOX 670287
CHUGIAK, AK 99567-
Parcel ID: 051-032-01
Site Address: 22713 MARGARET MELKE STREET
Lot Size: 108900 SQ. FT.
Total Bedrooms: 4 Permit Bedrooms: 4
This permit is for the construction of:
[] Disposal Field [] Septic Tank [] Holding Tank [] Privy
[] Private Well [] Water Storage
All construction must be in accordance with:
1. The attached approved design.
2. All requirements specified in Anchorage Municipal Code Chapters 15.55 and 15.65 and the State of Alaska
Wastewater Disposal Regulations ( 18AAC72 ) and Drinking Water Regulations ( 18AAC80 ).
3. The engineer must notify DSD at least 2 hours prior to each inspection. Provide notification by calling
(907) 3437904 ( 24 hours ). ( Not required for a Water Supply Permit only ).
4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather
must be either: A. Open and closed on the same day.
B. Covered, sealed, and heated to prevent freezing.
5. The following special provisions.
-THE UPPER SIX INCHES OF THE MOUND SYSTEM MUST CONSIST OF TOP SOIL AND THE MOUND MUST
BE VEGETATED SUFFICIENTLY TO PREVENT EROSION.
Received By: ~
Issued By'~.
Date: ~/7/~
Municipality of Anchorage
Development Services Department
Building Safety Division
On-Site Water and Wastewater Program
4700 Bragaw Street
P.O. Box 196650
Anchorage, AK 99519-6650
www.muni.org/onsite
(907) 343-7904
ON-SITE SEPTIC/~/ELL PERMIT APPLICATION
FOR A SINGLE FAMILY DWELLING
Parcel I.D. O51 ' O32"O I
Propertyowner(s) F~O. VI~ ./41~ I~
Mailing address PO ~ (70~7
Legal description (Sub'd. Block & Lot) ~o ~ ~
Legaldescription(Township, Section& Range) ~,~. ~ %/:~
Lot Size IO~, ~VO Sq. Ft. Number of Bedrooms
Day phone
zip Codo
75Y7
THIS APPLICATION IS FOR (~3all that apply):
Absorption Field [~
Septic Tank []
Holding Tank ~
Privy
Private Well ~]
Water Storage
THIS APPLICATION IS AN:
Initial ~
Upgrade
Renewal []
I certify that the above information is correct. I further certify Ihat this application is being made for a
Single Family Dwelling and is in accordance with applicable Municipal Codes.
(Signature of property owner or authorized agent)
Permit/Rush Fees:
Date of Payment:
Receipt Number:
(Rev. $1/05)
J~ (~ O. '~' Waiver Fees:
S'-/~ ¥/O (¢, Date pf Pa~ent:
0 ~ 0 ~ ~ ~~eceiPt Number:
r~3BERT C. COWAN. RE.
ROBERTA. SHAFER, RE.
May 22, 2006
CML ENGINEERS
(907) 694-2979
FAX (907) 694-1211
MUNICIPALITY OF ANCHORAGE
Development Services Department
P.O. Box 196650
Anchorage, AK 99519
REFERENCE: Lot 8, Section5, TI5N, RIW, S.M.
It is requested that you issue a permit to install a ne~v septic system to serve the
existing four bedroom dwelling on the referenced property.
A test hole was excavated and a percolation test performed. The approximate location of
the test hole is located on the attached site plan. At the time of excavation 5/11106, ground
water was not found. After monitoring, ground water was found at 12.5 feet.
We do not anticipate any adverse effects on neighboring wells, septic systems, reserve
areas or drainage patterns by the installation of the proposed septic system. The
construction of this system will not prevent any future development on any of the adjacent
properties.
If you require additional information, please contact us.
Sincerely,
RCC_.mjj
Enclosure
17034 NORTH EAGLE RIVER LOOP * SUfTE 204 · EAGLE FINER, ALASKA 99577
1" = 60' DESIGN SITE-PLAN
0 O0
<
MARGARET MELKE STREET ~ ..
~ 50 PATENT R.O.W. EASEMENT ~ · ~o
1" = 40' DESIGN SITE-PLAN
~ ~ ~ ~ ~ o
<
m
~RET MELKE STREET ~ ~
.2;....?
...... ,.~
x ~ .' .' · ' ~ /~.HIE, ~ ~
I
~
WATER WELL RECORD
STAT[ OF ALASKA
OEPARTMENT OF NATURAL RESOUR[S
Olvllion oIGeoIoglcQI 6 Gdophy~lcalSurvey~
.'..".;: l; I ~--ef--*,--u --
~1~1 DISTANCE AN00IR[¢TION FWOId ROAD INTEREECTIONS
,ri{ wi-1
[.OWNER OF WEkL:
4. w~L.~]OtPTH:fq).(ll.el) I 8. DATE.~ OF_ C.C~MPLETIOM,.=..;,L.j _ ..~
i
I--~ Irrillllin [--] #,lhe,e, [--I
1. CAOlND~ 0 Th,lodid ~:] Welded
dial.. ~', I.. Io I;3. ft. Oel~lh Wellhi ? Ibl./h.
IO. ITATIC WATER LEVEL: fl. / //
Dele
19. water TI,,I,e,QIu,, ' ~ Ir r'l C
Performed For:
Legal Description:
8-
9.
11-
20-
COMMENTS
Municipality of Anchorage ...~.,~...~ .--.
Development Se~lces Department ~,~[,~ ,
On-Site Water and Wastewater Program
4700 South Bragaw St.
p.o. ~o~ ~6~o ~c~o~ge. ~K ~S~-~O
Soils Log - Percolat,on Test j
Slope Site Plan
i
//
?
/
/
Reading Date Gross Time Net Time Depth lo Water Net Drop
/~u~D.
TEST RUN BETWEEN '~ FT AND I.~ FT
$ & S ENGINEERING oadNo 2,~ '//~ / ~'
PERFORMED DY: 17034 Eagle River L.pR · '~ ~~ CERTIFY THAT THIS ~ W~
PERFORMED IN AC~~ AND MUNICIPAL ~UIDELINES IN EFFECT ON THIS DATE. DATE: ~
ROBERTC. COWAN, RE.
ROBERTA. SHAFER, RE.
CIVIL ENGINEERS
(907) G94-2979
FAX (907) 694-1211
ON-SITE WASTEWATER DISPOSAL SYSTEM
CONSTRUCTION PRACTICES
and
MATERIAL SPECIFICATIONS
REFERENCE: Lot 8, Section 5, TISN, RIW, S.M.
May 22, 2006
GENERAL:
The scope of this project includes the installation of a new 1300 gallon
HDPE septic tank, pump basin, and pressurized trenches to serve the
existing four bedroom residence located on the referenced property.
Construction shall be in accordance with the approved site plan and design
drawings, Municipal permit with any special provisions or conditions, and
all applicable State and Municipal Wastewater Disposal Regulations.
3. The contractor shall be responsible for obtaining any necessary
underground utility locates.
Unless specifically agreed otherwise, the property owner shall be
responsible for final grading areas subsequently depressed from soil
settling.
Contractors installing wastewater disposal systems must be certified by the
Municipal Development Services Department or ADEC if required, for
system installations. Owners installing their own systems must also receive
prior approval from the respective agency.
SEPTIC TANK INSTALLATION:
A septic tank is to be constructed by a certified septic tank manufacturer.
Construction shall include two 4" cleanouts for pumping access.
The septic tank shall be sufficiently bedded to prevent settling or smiting of
the tank.
All standpipes on the septic tank shall extend a minimum of 12 inches
above final grade.
17034 NORTH EAGLE RIVER lOOP * SUITE 204 · EAGLE R~ER. ALASKA 99577
P~ge 2
I..~ 8, S~:~::~ 5, T15N, R1W, S.M.
4.
5.
6.
Septic tanks installed with less than 4 fl. ofcover shall be insulated.
A foundation eleanout shall be installed one to four feet from the building foundation.
Final grading over the septic tank shall be such that a positive slope exists away from
the septic tank.
ABSORPTION TRENCH/DRAINFIELD INSTALLATION:
Excavate the proposed trench to the dimensions shown on the design. The bottom of
the excavation shall be within 2 inches of level. If the sidewalls of the excavation
become smeared, they must be raked or scratched (ruffed-up) before gravel (sewer
rock) placement.
Once the gravel is installed, the distribution pipe is to be installed level with the holes
faced downward. The distribution piping is to be ofPVC (ASTM D3034 or equal).
Ail joints are to be solvent cemented. Gravel is then to be placed over the distribution
pipe to provide a minimum of 2 inches of cover over the pipe.
A silt barrier must be installed between the final gravel layer and the native soil
backfill. Ensure the silt barrier covers the entire gravel surface before placing backfill.
Monitor tubes shall be of four (4) inch diameter, installed approximately in the
locations shown on the design, and extend a minimum of 12 inches above final grade.
The portion of the monitoring tube extending through the gravel shall be perforated
from the bottom of the trench to the invert of the distribution pipe. This is equivalent
to the effective depth of the gravel as noted on the design.
Backfill over the final gravel layer must not be less than twenty-four (24) inches.
Insulation must be installed when the backfill depth is less than thirty-six (36) inches.
The finish grade over the trench must be mounded to prevent the formation of a
depression after settling.
Page 3
IJX 8, SectJ~ 5, T15N. RIW. $.M.
MINIMUM MATERIAL SPECIFICATIONS:
Any septic tank proposed for installation must be constructed by a Municipally
approved septic tank manufacturer.
The following pipe materials are approved for use in septic system installations in the
Municipality of Anchorage:
Type of Pipe Perforated Solid
Cast Iron Yes Yes
ASTM D3034 (PVC) Yes Yes
ASTM F810 (I-ff)PE) Yes No
ASTM D2662 (ABS) Yes Yes
Use of a type of pipe other than listed above must be approved by the inspecting
engineer.
3. Insulation shall be at least 2" thick extruded direct burial polystyrene (Dow Chemical
Company Styrofoam HI or equal).
4. Septic tank inlets and outlets shall be fitted with watertight couplings (Caulder, Femco,
or equal).
5. A permeable nontoxic silt barrier (Typar 3401, Mimfi 140N, or equal) must be installed
between the final leachfield gravel layer and the native soil backfill.
6. All leachfield gravel (sewer rock) shall be 0.5"-2.5" screened gravel with less than 3%
passing the #200 sieve.
7. When sand is being used as a filter material, its gradation specifications must conform to
current M.O.A. or D.E.C. requirements, which ever epecifieations applies.
Page
Lot 8. ,~ 5. 715N. R1W. $.M.
INSPECTIONS:
Typically there will be a minimum of three (3) inspections required during the installation of
the wastewater disposal system. These inspections will occur as follows:
The first inspection must be conducted after the excavation of ditches, pits,
trenches, or beds and before the installation of any gravel A septic tank maybe
set in place, but may not be backfilled before this inspection.
The second inspection must be conducted after the placement of the silt barrier,
gravel, distribution lines, standpipes, cleanouts, and insulation, but before the
placement of any other backfill.
3. The final inspection is to occur upon final grading of the property.
Often there will be more than these 3 inspections required. Especially with the installation of
multiple trenches, sand filters, pressurized distribution systems, etc. Thus, the inspecting
engineer is to be contacted at least 24 hours prior to the start of construction. If necessary, a
pre-construction meeting will take place on-site. The inspecting engineer will not coordinate,
direct or control in any way the contractors activities.
The owner shall conlxact with the contractor to perform the work outlined in these
specificatio~ and plans and in accordance with the attached M.O.A. permit. There will be no
contractual arrangement existing between the contractor and S & S Engineering. S & S
Engineering shall be the owner's representative and will inspect the work as stated above to
document the contractors activities. Final acceptance of the contractors work rests with the
owner and the M.O.A.
S & S Engineering shall have no liability to the owner or to others for acts or omissions of the
contractor or any other persons performing work on this project or the failure of the contractor
to carry out the work in accordance with these construction documents. S & S Engineering's
inspecting engineer will not be responsible for the construction means, methods, techniques,
sequence, procedures or the safety precautions incident to this project.
CONTRACTOR / INSTALLER
Municipality of Anchorage
Development Services Department
Building Safety Division
On-Site Water and Wastewater Program
4700 South Bragaw St.
P.O. Box 196650 Anchorage, AK 99519-6650
www.ci.anchorage.ak.us
(907) 343-7g04
ON-SITE SEWER/WELL SUBMITTAL COMMENT SHEET
To:
Legal description: .T.~a~&~
The attached paperwork has been reviewed and Is being returned for the following reasons:
Original signature or stamp missing on
Calculation error in design.
Additional soils information needed.
Water monitoring results inadequate.
Discrepancy in information submitted.
Topographic information missing or inadequate.
Incomplete; missing
Incomplete; missing_
Additional adequacy test information needed.
Water sample unacceptable.
Measured/proposed distances/dimensions missing.
Locations of all soils, percolation and water monitoring tests not shown. __
Proposed system too deep for soils information submitted.
Well log required.
Omission in narrative.
Insufficient fill over tank or field.
[] Other. Is them any well Ico or exlsflna eeotlc Info? what Is the seoaraflon from orooosed to extslno seotlc?
Name of reviewer: JOE GOODA/t. Date: 5/3112006
Please supply the necessary information and re-submit your request.
LEAVE THIS FORM ATTACHED TO THE PAPERWORK