HomeMy WebLinkAboutT15N R1W SEC 5 LT 8T15N R1W SEC 5 SM LOT 8 051-032-01 EXPIRED PERMIT Mayor Mark Begich Municipality of Anchoragc Department December 6, 2007 Frank Melke PO BOX 670287 Chugiak, AK 99567 Subject: NOTICE OF VIOLATION T15NR1WSEC 5 SM LOT8 On-Site Water & Wastewater Permit (s,~)60139) Certified Mail #:70042510000198885206 Dear Frank Melke: The final inspection report for your wastewater system has not been received by the On- Site Water and Wastewater Program office. This letter will serve as a Notice of Violation that there is an unapproved water and/or wastewater system at this location. Anchorage Municipal Code requires: · Within 30 working days from the date of the final inspection of an on-site wastewater disposal system, an inspection report, shall be submitted to the department by the owner or his agent. The report must bear the seal of an engineer and be on a form and to standards prescribed by the department. · No person may cause or permit any wastewater to be discharged or disposed of except into an on-site wastewater disposal system conforming to state and municipal standards. In order to avoid future enforcement actions, which may include fines, please contact your engineer to resolve this violation. An inspection report for the subject wastewater system must be received by this office ~fithin two weeks ofthe date on this letter. Thank you for your cooperation in this mat~er. Please call the On-Site Water and Wastewater Program at 343-7904 if you have any questions. Sincerely, Jeff Poet Engineering Technician On-Site Water & Wastewater Program Community, Security, Prosperity ~ PO BOX 670287  Chugiak, AK 99567 Wockenfuss, Deborah M. From: Sent: To: Subject: Moeller, Laura Jo Wednesday, April 30, 2008 1:45 PM Wockenfuss, Deborah M. RE: Mielke Status Right of Way section says MOA has jurisdiction. Refer any questions to Larry Ison or Tom Knox (because I sure as heck can't explain it). Are you back at your desk? I took this paperwork over to you, but you had stepped away. From: Wockenfuss, Deborah M. Sent: Monday, April 14, 2008 8:22 AM To: Moeller, Laura Subject: RE: Mielke Status Thank you, Deb Wockenfuss Onsite Water/Wastewater Department Municipality of Anchorage 343-7906 From: Moeller, Laura .lo Sent: Friday, April 11, 2008 3:13 plVl To: Wockenfuss, Deborah M. Subject: rvlielke Status Hi Debbie! Vicki Gerken and Tom Knox are helping determining MOA interest in the BLM Patented ROW along the north side of the Mielke lot. Some of the documentation provided to me by Mielke is irrelevant, but they need to look more into the Small Tracts deal. It is taking some time to do the research, and Tom is going on vacation tonigh, but meanwhile, if you have questions re the status, please contact Vicki Gerken. Municipality of Anchorage Development Services Department Building Safely Division On-Site Water and Wastewater Program 4700 South Bragaw St. P.O. Box 196650 Anchorage, AK 99519-6650 wv~v. munLorg/onsite (907) 343-7904 ON-SITE SEWER/VVELL SUBMITTAL COMMENT SHEET To: Bob Legal description: _'I'15N RIW ,5~ctlon 5 Lot R The attached paperwork has been reviewed and is being returned for the following reasons: Original signature or stamp missing on Calculation error in design.. Additional soils information needed. Water monitoring results inadequate. ,, Discrepancy in information submitted. Topographic information missing or inadequate. Incomplete; missing ~Dl~ovel f~m Right of Way Department fro' trench in easement, Incomplete; missing. Additional adequacy test information needed. Water sample unacceptable.. Measured/proposed distances/dimensions missing. Locations of all soils, percolation and water monitoring tests not shown.. Proposed system too deep for soils information submitted.. Well log required., Omission in narrative. Insufficient fill over tank or field. Other. Name of reviewer: 3'eff Date: .12-22-O6 Please supply the necessary information and re-submit your request. LEA VE THIS FORM ATTACHED TO THE PAPERWORK O Municipality of Anchorage Development Services Department Building Safety Division On-Site Water and Wastewater Program, 4700 Bragaw St. P.O. Box 196650 Anchorage, AK 99519-6650 Page ~ of~,' www.ci.anchorage.ak.us (907) 343-7904 ON-SITE WASTEWATER DISPOSAL SYSTEM AND/OR WELL INSPECTION REPORT Permit Number: ~ [.'~,,q~ C) ~ 0' i '~ ~' PID Number: Name: ~¢~*q~ ~l ~ WastewaterSystem: ~ New ~Upgrade '"" ' q~S-~'7 ABSORPTION FIELD Phone: /~~ ?'7~~ Number Deep Trench ~Shallow Trench ~Bed ~Mound Soil Rating: Total Depth from original grade: ~ Ft. LEGAL DESCRIPTION J, ~ Block: Lot: ~ Subdivision: Depth to pipe bottom fro~ original grade:~ Gravel depth beneath pipe: Tow,~hi~: ~? Rano.: ~ L.~) S~ot,on:~ "i"~dd~d~v~°~i*a'~'~d~--3¢ I ~'. ~,~w,~.¢h: :~ ,t. Well: ~ New ~ Upgrade G~aw~ w~dth: ~~t. N~m~e~,~of ~i~e~: D~st~*o~ ~t~en~ ~in~:~t. C,Bssifioation (~,ivate, A. ,~): , ; Total Depth: Cased to: Total absorption area: ('/10 P,e M~teria,: Dril~__.~ Date D[,,~: Static Water Level: Instafler: Date Installed: Yield: ............... [~mp Set at: Casing ~e~~d: ~ ~ O~ ~ ~' ............ GPM/ Ft. ~Ft. TANK SEPARATION DISTANCES ~Semio D Holdi~ D S.T.E.P. Tank Field Station Tank Sewer Line ~ ~-~ I~:, ~ ~! ~% ~ ~ Material: Well i¢~i j ~.} ~ ~ I I / ~.. ~ P¢¢ Number°fC°mpadments: Lot Line Manufact ..... Cu~ainDrain '- -- ~?'~''~* ~O'2:~1~ ~'t~*~j~r~-~umpMake&MOde, Electrioallnspectionspedormedby:~X ! - Location and Description: Inspections performed by:lT~E~leRiv~L~R~d, Ne'g~s' 1~t g-/ '/-L~ Development Se~ice~ B~nndment Approval Conditional Approval ~ O ¢ Date: ~,~i,~Ted and approvec Date: PERMIT NO. SW060139 PAGE 2 OF 4 Hunicip, aLi-t;v o¢' Anchoro, ae DEPARTMENT OF HEALTH AND HUH'AN SERVICES ENVIRONMENTAL $ERVlCE$ DIVI$10N P,D, Box 196650 eAnchorage, ALaska 99519-6650 e TeLephone: 343-4744 ON-SITE WASTEWATER DISPOSAL SYSTEM AND/OR WELL INSPECTION REPORT r.EGA~. LOT 8, SECTION 5, T15N, RlW P.I.D. NO. 051--032--01 CONLEY AVENUE (NOT CONSTRUCTED) ENg~STAUP 717: - I PERMIT NO, SW060139 PAGE 3 OF 4- Plunici~Li~y oF Anc½omaQe DEPARTiVlENT OF HEALTH AND HUIVTAN SERVICES ENVIRONMENTAL SERVICES DIVISION P,EI, ]}ox 196650 e Anchomage, A(~sk~ 99519-6650 ® TeLephone', 343-4744 ON-SITE WASTEWATER DISPOSAL SYSTEN AND/OR WELL INSPECTION REPORT LEGAL LOT 8, SECTION 5, T15N, RlW P.I.D. NO. 051--0,.52--01 MT1 TRENCHES CONLEY AVENUE (NOT CONSTRUCTED) gI TH MT4 TMT ] 300 GALLON f HDPE SEPTIC TANK MT2 ST2 iNSU LATED~NN~ UNDER ~. D R~V~co ~ EWAY '~ ~gS,~oo,' ~0' '~'~ - I ENGINEER STAMP-: ~Oo, ' .c~~ ~1 ?'..:' ~' -N¢~ PERMIT NO SW060139 PAGE 3 OF 3 Municip, o,(i-i:...¥_..oF Anchor'a(:e DEPARTMENT OF HEA~LTHAND HUMAN SERVICES ENVIRONMENTAL SERVICES DIVISION P,O, ]3ox 196650 ·Anchorage, Alaska 99519-6650·TeLephone: 343-4744 ON-SITE WASTEWATER DISPOSAL SYSTEM AND/OR WELL INSPECTION REPORT LEGAL LOT 8, SECTION 5, T15N, RlW P.I.D. NO. 051-032-01 FINAL GRADE--N ST1 ST2 C01 MT2 100 7'~MT1 [-] [] , , MT3n n MT4 ' kll 11/--101.4 101.5-x II II 101 ........... 1.1 ........... 1}.... II 1i ,'~:'.:,i:i:'! S A N D (i;!i,~:f' - 997 MT2 - ga a' i 8' MT1 - - ....... - .... / ~,.;~,~q x_ MT4 98. MT3 -- 98.7' ~' A B ST1 14.5' 21.0' ST2 12.5' 24.0' TMT 1,.5.0' 26.5' CO 12.0' 26.5' MH 12.0' 28.5' MT1 82.0' 88.5' MT2 24.5' 4,5.0' MT,.5 80.0' 81.0' MT4 22.5' 50.0' · WATER FOUND ® 88.2' 86.7' B.O.H. N. T. S. EN( STAMP METRO ELECTRIC,, INC. ELECTRICAL CONTRACTING P.O. BOX 671189. CHUGIAK · ALASKA 99567 PHONE (907) 277-1392 · FAX (907) 274-4705 DATE: INVOICE NO. July 12, 2006 2686 A-I-rENTION: Frank Mielke TO: Frank Mielke Chugiak, AK 99567 REFERENCE: Kurt Koehler Instil ~er furnished ~uipment or ~er I~ ~taflon. Provide ~m and mi~eflan~us ele~ical items. 210' ~12 THHN s~n~ wire ~s.2~ $ 55.91 280' ~18 THHN s~id ~re ~ 14.74~ 32.12 I lot misc wire n~, ~ ~, etc. 2.00 6 Houm labor et~dans 70.O0thr 420,00 NO~: nl mate,als ~ ~ui~'fi~;~~~~and I~1 ~0~. We have ~ ~a~:~~~~~h~ materials MUNICIPALIT~ OF ANCHORAGE Development Services Department On-Site Water & Wastewater Program 4700 South Bragaw Street P.O. Box 196650, Anchorage, AK 99519-6650 (907) 343-7904 ON-SITE WASTEWATER DISPOSAL SYSTEM PERMIT Upgrade Date Issued: Jun 07, 2006 Expiration Date: Jun 07, 2007 Permit Number: SW060139 Legal Description: T15N R1W SEC 5 SM LOT 8 Design Engineer: 0003 S & S Engineering Owner Name: FRANK MELKE Owner Address: PO BOX 670287 CHUGIAK, AK 99567- Parcel ID: 051-032-01 Site Address: 22713 MARGARET MELKE STREET Lot Size: 108900 SQ. FT. Total Bedrooms: 4 Permit Bedrooms: 4 This permit is for the construction of: [] Disposal Field [] Septic Tank [] Holding Tank [] Privy [] Private Well [] Water Storage All construction must be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal Code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations ( 18AAC72 ) and Drinking Water Regulations ( 18AAC80 ). 3. The engineer must notify DSD at least 2 hours prior to each inspection. Provide notification by calling (907) 3437904 ( 24 hours ). ( Not required for a Water Supply Permit only ). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must be either: A. Open and closed on the same day. B. Covered, sealed, and heated to prevent freezing. 5. The following special provisions. -THE UPPER SIX INCHES OF THE MOUND SYSTEM MUST CONSIST OF TOP SOIL AND THE MOUND MUST BE VEGETATED SUFFICIENTLY TO PREVENT EROSION. Received By: ~ Issued By'~. Date: ~/7/~ Municipality of Anchorage Development Services Department Building Safety Division On-Site Water and Wastewater Program 4700 Bragaw Street P.O. Box 196650 Anchorage, AK 99519-6650 www.muni.org/onsite (907) 343-7904 ON-SITE SEPTIC/~/ELL PERMIT APPLICATION FOR A SINGLE FAMILY DWELLING Parcel I.D. O51 ' O32"O I Propertyowner(s) F~O. VI~ ./41~ I~ Mailing address PO ~ (70~7 Legal description (Sub'd. Block & Lot) ~o ~ ~ Legaldescription(Township, Section& Range) ~,~. ~ %/:~ Lot Size IO~, ~VO Sq. Ft. Number of Bedrooms Day phone zip Codo 75Y7 THIS APPLICATION IS FOR (~3all that apply): Absorption Field [~ Septic Tank [] Holding Tank ~ Privy Private Well ~] Water Storage THIS APPLICATION IS AN: Initial ~ Upgrade Renewal [] I certify that the above information is correct. I further certify Ihat this application is being made for a Single Family Dwelling and is in accordance with applicable Municipal Codes. (Signature of property owner or authorized agent) Permit/Rush Fees: Date of Payment: Receipt Number: (Rev. $1/05) J~ (~ O. '~' Waiver Fees: S'-/~ ¥/O (¢, Date pf Pa~ent: 0 ~ 0 ~ ~ ~~eceiPt Number: r~3BERT C. COWAN. RE. ROBERTA. SHAFER, RE. May 22, 2006 CML ENGINEERS (907) 694-2979 FAX (907) 694-1211 MUNICIPALITY OF ANCHORAGE Development Services Department P.O. Box 196650 Anchorage, AK 99519 REFERENCE: Lot 8, Section5, TI5N, RIW, S.M. It is requested that you issue a permit to install a ne~v septic system to serve the existing four bedroom dwelling on the referenced property. A test hole was excavated and a percolation test performed. The approximate location of the test hole is located on the attached site plan. At the time of excavation 5/11106, ground water was not found. After monitoring, ground water was found at 12.5 feet. We do not anticipate any adverse effects on neighboring wells, septic systems, reserve areas or drainage patterns by the installation of the proposed septic system. The construction of this system will not prevent any future development on any of the adjacent properties. If you require additional information, please contact us. Sincerely, RCC_.mjj Enclosure 17034 NORTH EAGLE RIVER LOOP * SUfTE 204 · EAGLE FINER, ALASKA 99577 1" = 60' DESIGN SITE-PLAN 0 O0 < MARGARET MELKE STREET ~ .. ~ 50 PATENT R.O.W. EASEMENT ~ · ~o 1" = 40' DESIGN SITE-PLAN ~ ~ ~ ~ ~ o < m ~RET MELKE STREET ~ ~ .2;....? ...... ,.~ x ~ .' .' · ' ~ /~.HIE, ~ ~ I ~ WATER WELL RECORD STAT[ OF ALASKA OEPARTMENT OF NATURAL RESOUR[S Olvllion oIGeoIoglcQI 6 Gdophy~lcalSurvey~ .'..".;: l; I ~--ef--*,--u -- ~1~1 DISTANCE AN00IR[¢TION FWOId ROAD INTEREECTIONS ,ri{ wi-1 [.OWNER OF WEkL: 4. w~L.~]OtPTH:fq).(ll.el) I 8. DATE.~ OF_ C.C~MPLETIOM,.=..;,L.j _ ..~ i I--~ Irrillllin [--] #,lhe,e, [--I 1. CAOlND~ 0 Th,lodid ~:] Welded dial.. ~', I.. Io I;3. ft. Oel~lh Wellhi ? Ibl./h. IO. ITATIC WATER LEVEL: fl. / // Dele 19. water TI,,I,e,QIu,, ' ~ Ir r'l C Performed For: Legal Description: 8- 9. 11- 20- COMMENTS Municipality of Anchorage ...~.,~...~ .--. Development Se~lces Department ~,~[,~ , On-Site Water and Wastewater Program 4700 South Bragaw St. p.o. ~o~ ~6~o ~c~o~ge. ~K ~S~-~O Soils Log - Percolat,on Test j Slope Site Plan i // ? / / Reading Date Gross Time Net Time Depth lo Water Net Drop /~u~D. TEST RUN BETWEEN '~ FT AND I.~ FT $ & S ENGINEERING oadNo 2,~ '//~ / ~' PERFORMED DY: 17034 Eagle River L.pR · '~ ~~ CERTIFY THAT THIS ~ W~ PERFORMED IN AC~~ AND MUNICIPAL ~UIDELINES IN EFFECT ON THIS DATE. DATE: ~ ROBERTC. COWAN, RE. ROBERTA. SHAFER, RE. CIVIL ENGINEERS (907) G94-2979 FAX (907) 694-1211 ON-SITE WASTEWATER DISPOSAL SYSTEM CONSTRUCTION PRACTICES and MATERIAL SPECIFICATIONS REFERENCE: Lot 8, Section 5, TISN, RIW, S.M. May 22, 2006 GENERAL: The scope of this project includes the installation of a new 1300 gallon HDPE septic tank, pump basin, and pressurized trenches to serve the existing four bedroom residence located on the referenced property. Construction shall be in accordance with the approved site plan and design drawings, Municipal permit with any special provisions or conditions, and all applicable State and Municipal Wastewater Disposal Regulations. 3. The contractor shall be responsible for obtaining any necessary underground utility locates. Unless specifically agreed otherwise, the property owner shall be responsible for final grading areas subsequently depressed from soil settling. Contractors installing wastewater disposal systems must be certified by the Municipal Development Services Department or ADEC if required, for system installations. Owners installing their own systems must also receive prior approval from the respective agency. SEPTIC TANK INSTALLATION: A septic tank is to be constructed by a certified septic tank manufacturer. Construction shall include two 4" cleanouts for pumping access. The septic tank shall be sufficiently bedded to prevent settling or smiting of the tank. All standpipes on the septic tank shall extend a minimum of 12 inches above final grade. 17034 NORTH EAGLE RIVER lOOP * SUITE 204 · EAGLE R~ER. ALASKA 99577 P~ge 2 I..~ 8, S~:~::~ 5, T15N, R1W, S.M. 4. 5. 6. Septic tanks installed with less than 4 fl. ofcover shall be insulated. A foundation eleanout shall be installed one to four feet from the building foundation. Final grading over the septic tank shall be such that a positive slope exists away from the septic tank. ABSORPTION TRENCH/DRAINFIELD INSTALLATION: Excavate the proposed trench to the dimensions shown on the design. The bottom of the excavation shall be within 2 inches of level. If the sidewalls of the excavation become smeared, they must be raked or scratched (ruffed-up) before gravel (sewer rock) placement. Once the gravel is installed, the distribution pipe is to be installed level with the holes faced downward. The distribution piping is to be ofPVC (ASTM D3034 or equal). Ail joints are to be solvent cemented. Gravel is then to be placed over the distribution pipe to provide a minimum of 2 inches of cover over the pipe. A silt barrier must be installed between the final gravel layer and the native soil backfill. Ensure the silt barrier covers the entire gravel surface before placing backfill. Monitor tubes shall be of four (4) inch diameter, installed approximately in the locations shown on the design, and extend a minimum of 12 inches above final grade. The portion of the monitoring tube extending through the gravel shall be perforated from the bottom of the trench to the invert of the distribution pipe. This is equivalent to the effective depth of the gravel as noted on the design. Backfill over the final gravel layer must not be less than twenty-four (24) inches. Insulation must be installed when the backfill depth is less than thirty-six (36) inches. The finish grade over the trench must be mounded to prevent the formation of a depression after settling. Page 3 IJX 8, SectJ~ 5, T15N. RIW. $.M. MINIMUM MATERIAL SPECIFICATIONS: Any septic tank proposed for installation must be constructed by a Municipally approved septic tank manufacturer. The following pipe materials are approved for use in septic system installations in the Municipality of Anchorage: Type of Pipe Perforated Solid Cast Iron Yes Yes ASTM D3034 (PVC) Yes Yes ASTM F810 (I-ff)PE) Yes No ASTM D2662 (ABS) Yes Yes Use of a type of pipe other than listed above must be approved by the inspecting engineer. 3. Insulation shall be at least 2" thick extruded direct burial polystyrene (Dow Chemical Company Styrofoam HI or equal). 4. Septic tank inlets and outlets shall be fitted with watertight couplings (Caulder, Femco, or equal). 5. A permeable nontoxic silt barrier (Typar 3401, Mimfi 140N, or equal) must be installed between the final leachfield gravel layer and the native soil backfill. 6. All leachfield gravel (sewer rock) shall be 0.5"-2.5" screened gravel with less than 3% passing the #200 sieve. 7. When sand is being used as a filter material, its gradation specifications must conform to current M.O.A. or D.E.C. requirements, which ever epecifieations applies. Page Lot 8. ,~ 5. 715N. R1W. $.M. INSPECTIONS: Typically there will be a minimum of three (3) inspections required during the installation of the wastewater disposal system. These inspections will occur as follows: The first inspection must be conducted after the excavation of ditches, pits, trenches, or beds and before the installation of any gravel A septic tank maybe set in place, but may not be backfilled before this inspection. The second inspection must be conducted after the placement of the silt barrier, gravel, distribution lines, standpipes, cleanouts, and insulation, but before the placement of any other backfill. 3. The final inspection is to occur upon final grading of the property. Often there will be more than these 3 inspections required. Especially with the installation of multiple trenches, sand filters, pressurized distribution systems, etc. Thus, the inspecting engineer is to be contacted at least 24 hours prior to the start of construction. If necessary, a pre-construction meeting will take place on-site. The inspecting engineer will not coordinate, direct or control in any way the contractors activities. The owner shall conlxact with the contractor to perform the work outlined in these specificatio~ and plans and in accordance with the attached M.O.A. permit. There will be no contractual arrangement existing between the contractor and S & S Engineering. S & S Engineering shall be the owner's representative and will inspect the work as stated above to document the contractors activities. Final acceptance of the contractors work rests with the owner and the M.O.A. S & S Engineering shall have no liability to the owner or to others for acts or omissions of the contractor or any other persons performing work on this project or the failure of the contractor to carry out the work in accordance with these construction documents. S & S Engineering's inspecting engineer will not be responsible for the construction means, methods, techniques, sequence, procedures or the safety precautions incident to this project. CONTRACTOR / INSTALLER Municipality of Anchorage Development Services Department Building Safety Division On-Site Water and Wastewater Program 4700 South Bragaw St. P.O. Box 196650 Anchorage, AK 99519-6650 www.ci.anchorage.ak.us (907) 343-7g04 ON-SITE SEWER/WELL SUBMITTAL COMMENT SHEET To: Legal description: .T.~a~&~ The attached paperwork has been reviewed and Is being returned for the following reasons: Original signature or stamp missing on Calculation error in design. Additional soils information needed. Water monitoring results inadequate. Discrepancy in information submitted. Topographic information missing or inadequate. Incomplete; missing Incomplete; missing_ Additional adequacy test information needed. Water sample unacceptable. Measured/proposed distances/dimensions missing. Locations of all soils, percolation and water monitoring tests not shown. __ Proposed system too deep for soils information submitted. Well log required. Omission in narrative. Insufficient fill over tank or field. [] Other. Is them any well Ico or exlsflna eeotlc Info? what Is the seoaraflon from orooosed to extslno seotlc? Name of reviewer: JOE GOODA/t. Date: 5/3112006 Please supply the necessary information and re-submit your request. LEAVE THIS FORM ATTACHED TO THE PAPERWORK