Press Alt + R to read the document text or Alt + P to download or print.
This document contains no pages.
HomeMy WebLinkAboutWALTER G PIPPEL ADDITION BLK 7 LT 5Walter G *
P"Iel AddPPition
Block 7
Lot 5
#050-124-08
Apr 16 13 11:51a Sullivan 1Naier Vdells 9Q7 688 2759
artttteb �Drttttug 'Log
by
(Y^C CO. dba
SULLIVAN WATER WELLS
P.O. BOX 670"" CHUGIAK, ALASKA 99567 • TELSPHONE 696.2759
OWNER Of- !AN:-):_�` �la�lf5 �.—__..----
ACCRES.S:--
LEGAL
i
PERMIT NUWBER! _J_e, 3,�`; Date of lss-PLS'_-._ __i_2f
Tax IDENTIFICATION NL!MBE;.:
Is well located at approvedoen-nitecati,nl G i'Jo
Mett)od of Drilling: i' rotary 1 carne tool
Deoth of well: _ __!�d_---------�----
Casing Type
s�/%£'' alThiCkness____.�irches
Diameter— _lG�.�..jnCheS,depth
Liner Type: _._ti �"'"!=__—_._--
Casing Stickup
Static Winer Levet..—..- fees
Recove, Rate:——qpm
Method of le3ting: -
Well Intake, Opening Type: .t or.en eia IJ oilerho e
1Sc'eened; Start __—.---feet Stopped ----
- ;eet
t _ r`orat'ons Start._�-U. _feet Stoppedfeet
Grout Type:, la iJ'�'�)'n'Vo I
.._------
Deptn: from feet, to-------.--_-_ teet
4Wif Disinfected Upon Completion? �n-<s IU fjo
Method of Cisinfectior.:sY� t7�? 1- —4
Commarts:
Criller's Name:,_v�
p%7. EN [ION: It is the respors bility of the prooerty owrner to subrr t a Copy of the v:cit log to the proper authority. Municipality
of Anchorage; Ceparmnert or Health & : furnan Services an v+,ror Department of E-tvirormental Conservation. Matsu Borough:
Derartmem of Environmental Conservation.
ARCTIC PUMP & WELL INC.
Jim Sullivan
j{y�7 PO Box 770197
'�'m" Eagle River, AK 99577
(907)688-2510
(907)258-2510
(907)745-2510
aow(weci.net
Pump Installation Log
Well Drilling Permit Number: osp121325
Parcel Identification Number: 05012408000
Date Of Issue: 10/3/2012
Tuesday, February 26, 2013
Legal Description waft g pippel addition B7 L5
Property Owner Name Address:
Paul Gibbs est of
Lot: 5
392 N Eklutna St
Block: 7
Palmer AK 99645
Pump Installaion Date: 2/25/2013
Pump Intake Depth Below Top of Well Casing: 55 Feet
Pump Manufacturer's Name Franklin
Pump Model: 10JS05P4-2W 115
Pump Size: 112
Pitless Adapter Burial Depth: 13 Feet
Pitless Adapter Manufacturer's Name B-10
Pitless Adapter Installer: U1K
Well Disinfected Upon Completion? Yes
Method of Disinfection: Chlorine
Comments:
PumpinstallerName:
Arctic Pump & Well, Inc.
Tuesday, February 26, 2013
On -Site Water System Permit
MUNICIPALITY OF ANCHORAGE
Development Services Department
On -Site Water & Wastewater Program
4700 Elmore Road, PO Box 196650
Anchorage, AK 99519-6650
Telephone: (907) 343-7904
Permit Number: OSP121325
Tax Code Number: 05012408000
Work Type: Well Initial
Permit Effective Dates: October 03, 2012 to October 03, 2013
Design Engineer:
Subdivision: WALTER G PIPPEL ADDITION
Site Legal Address: WALTER G PIPPEL ADDITION BILK 7 LT 5 G:0252
Owner/Address: GIBBS PAUL N
PO BOX 770445 EAGLE RIVER AK 995770445
Site Mailing Address: 16923 EASY ST, Eagle River
This permit is for the construction of:
N Disposal Field N Septic Tank N Holding Tank
Lot Size in Sq Ft: 13500
Total Bedrooms: 1
N Privy Y Private Well N Water Storage
All construction must be in accordance with:
1. The attached approved design.
2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater
Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80).
3. The wastewater code requires inspections during the installation. The engineer must notify the Development Services
Department at least 2 hours prior to each inspection. Provide notification by calling (907) 343-7904 (24 hours).
4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must either:
A. Open and Close on the same day.
B. Covered, sealed, and heated to prevent freezing.
Special Provisions: The well shall be drilled 100 feet minimum from the edge of both the septic
tank and drainfield.
Received
Issued By,
MUNICIPALITY OF ANCHORAGE
Community Development Department Phone: 907-343-7904
Development Services Division Fax: 907-343-7997
On -Site Water & Wastewater Program
C ON-SITE SEWER/WELL PERMIT APPLICATION
Parcel I.D. o56-1ay- O$
Property owner(s) Esf4 )•-e t& Pw� n �A 5 Day phone 961,-07`f5
Mailing address 3 9 F -ml '+rlg S+ Pctjvvl /' /3' i
Site address Easy Supe f E4 y1.- /Z;ev
1511
Legal description (Sub'd., Block & Lot) _,i ®IdXN+tr G• P��� �}1�' �i�k �) Lt J
Legal description (Township,
Range & Section)
Lot Size q. Ft.
APPLICATION IS FOR:
(M all that apply)
Absorption Field
❑
Septic Tank
❑
Holding Tank
❑
Privy
❑
Private Well
91
Water Storage
❑
Number of Bedrooms I
APPLICATION IS AN: TYPE OF DWELLING:
Initial ® Single Family (SF)
(w/wo ADU)
Upgrade ❑ Duplex (D) ❑
Renewal ❑ Multiple Dwellings ❑
(SF and/or D)
THIS APPLICATION INCLUDES A VARIANCE / WAIVER REQUEST FOR:
Distance:
certify that the above information is correct. I further certify that this is in accordance with
applicable Municipal Codes.
90-411n.y
(Signature of property owner or
G=�bbs �sfipt�
Permit/Rush Fees: ILbo ` Waiver Fees:
Date of Payment: nl Id511'3 GL4 100 Date of Payment:
Receipt Number: 151 aOlS Receipt Number:
Permit No. o5eu lbas Waiver No.
Permit App_9-1-12.doc
4d timed
t [
a location of the structure(s)as
3 6 ' 1 � L s own on this record drawing
. -- (a ui) co li 7itle2�f , At�C.
By: t
Pursuant to AMC 21[.�p.33f).B: I ` ti Dat Cp
"Tbe total width of driveway g
entrances to`a lot frog a street �a
shall not exceed two fifths of o o
the_frontage of that 11t on that streeY� y
ivdaxiMUM width j24L
IRI
Loft 5
1692-3aC/n4 Ciiy VA'}'¢
®r Sewer
AS -BUILT
I_hereby certify that I have surveyed the following described
Anchorage Recbiding Precinct Alaska and that the unprave- -
�,, w \ ments'sitirated thereon are within thepropertylines anddo not
$y overlap or encroach on the property.3y g dj nt thereto; that
.` no improvements ori property lying adjacent: thereto encroach
on the premises in question and t%at there are no roadways,
'• �� ,o. transmission 8ries .or other visible easements on said property .
except as indicated hereon.
'"s?"Dated at Eagle River, Alaska
Fol.ertC ¢�firts�'n.° � -
.m this-,! fi' <-;,/.`, . ... 9 ,
day of r 200
SCALE:
ROBERT C. and Su JOHNSON " ;?r.' �y :.
i,. _ Registered Land Surveyor ho 880 -LS
-_C - Sox 77,0456, Eagle River, Alaska 99577
Phone (907) 694-2593
y (oma f
�3
1
r
5
3 L
I
wore
�j a C-wn �
TSR -1'Y j s n b
bit 1 n(ts of C+y Seuf,
®fL'_uny Con'Fctrngj- ny sore,,
-.4
N
V
N
fs
S
'1
�.� Municipality of Anchorage
Development Services Department
-_ Building Safety Division
P.O. Box 196650 Anchorage, AK 99519
On -Site Water and Wastewater Program, 4700 Bragaw St
fi650 page i D13
www.cl.anchorage Bk.us (907) 343-7904
ON-SITE WASTEWATER DISPOSAL SYSTEM AND/OR WELL INSPECTION REPORT
N� I_I - rry ,�uneueC V:JS_l.-I aJC `/ ^(IrJ
G Uf Wastewater System: ❑New ,Upgrade
1 ^ < < S ABS
S/"),3
FIELD
P"' V ) —�* [� NuMwdBModns
�f J � O U•W Tr«rlr AShaMw TwrrUl O Bao O MdaM O OIMr
LEGAL DESCRIPTION $W RNn° Tdn Dope hdndP Wpaw ,�
9ipck Ld r , D GPM'
J\ �•PIn b DSM Dondn hdn dgrul usCe Gr&M dW I Eer Whh
Tp"'^sMP Rnpa �i0^ ' Faa it mmprrnp _ --'J FL Z
Grw«L«rpin
/� ".
Well: ❑New El Upgrade c a ""0tl N� co Wm
as uM1 .I m tPnr«a•A B. C) Twa Depen Cnae b J FI. / •�-
1'J 5 .� tdd'hedq,on«u P Z/,
prar DaTDieNC SIn4 W«« LhN F, V l'�Flr .71 I D�f� L `
M'n'« Ons h 11101 e 1/1
YNW PI«O 5«n F' ©to G 7— —
Gaeq 1rs i
GPM F,. n. TANK
SEPARATION DISTANCES Of Septic ❑Holden
To Septic Absorption Lift Holding ubeicVmate 9 S T.E.P. ❑ Other:
From eu.«
Tank Field Station Tanke"e1"^
G
Sewer Line 'F U/M d
we 1 � L � Mal«nl Hy'I�a' a cdro«rmem
S.f. W««
7 LIFT STATION
Ld Lne 1 Q 1 us ecru«
^''�V�f Gel
Fdne m L S / 1 .P�riP ai MvN n Yh.nP bwl ai _.
h
C~ Dr«nof �PurO MMs a ENdr,cel H
. /'`l, epadrom pMamsdq
AEX 1t r ll
C BENCH MARK
\ loulwn ane Dasoprwn \
(9111 .6� 1 11mac% i Fx�ly �f -5
W� e \\ h.ngn
1rn p IOOF,
S i S KNOINEIRING
Inspections performed by: 17071 L I� Rlwr L En
y w esp Read, Ne.�s: 1" %'� %'�%l OF
nd
Eegb Rlwr, A u a 2-19-06 r ��`�r •••�qS
Development Services Department Approval
Conditional Approval° r
Date: ° �_
p ROBERT G COWAN Q
ev C: 66 1
Reviewed and approved
ram aftr
n
FI
PERMIT No. SW060144
PACE 2 OF 3
Municipalitof Anchorage
DEPARTMENT OF HEAUH AND HUMAN SERVICES
ENVIRONMENTAL SERVICES DIVISION
P.O. Box 196650 *Anchorage, Ataska 99519-6650 • Te�l'ephone 343-4744
ON-SITE WASTEWATER DISPOSAL SYSTEM AND/OR WELL INSPECTION RVPORT
LEGAL LOT 5, BLOCK 61 WALTER G PIPPEL S/D P.I.D. No. 050-124-08
(APPROXIMATE RADIUS
LOCATION)
SEPTIC
C AREA LOT 8 LOT 7
10' M.N.
ALT. SITE
SEPTIC — —
EA 4 SEPTI
1ARATH to, MIN. .AREA
00' WELL RADIUS NEW TRENCH
APPROXIMATE LOCATION) C01 aCO2
OBL2 1 MT2� \
DBL1 / \
ST2 NEW 1000 GALLON
STI SEPTI TANK
TMT
LOT 4 // TOM FED LOT 6
00 100' WELL RADIO
I Fpm (APPROXIMATE LOCATION y
/ MIo� OBJ
W mu QP
^ v
DECK 3`v
•DECOMISSIONED WELL oo
�•'� POSSIBLE FUTURE
WELL LOCATION
SCALE V
j EASY STREET ^`N �•.... qs
1
00' WELL RADIUS �' C) o••+'
1 APPROXIMATE LOCATION) r .j i• ••''.�'9
�,• ROIERT,C•AN
C�p�yyJw
\� LOT 8
E- so
LOT 9A UNDEVELOPED
PERMIT NO. SW060144
PACE 3 OF 3
Municipalit of Anchora e
DEPARTMENT OF HEATH AND HUMAN SERVICES
ENVIRONMENTAL SERVICES DIVISION
hone: 343-4744
ON-SITE WASTEWATER6650 *DISPOSALAlaska SYSTEMIAND/OReIWELL INSPECTION REPORT
LEGAL LOT 5, BLOCK 6 WALTER G PIPPEL S/D P.I.O. NO. 050-124-08
1 ST2 100.0'
FINAL GRADE
97.0'X I NEW 1000 9
GALLON
SEPTIC TANK
MT2 = 92.2'
CO1
MT2C0:'p',--FINAL
CO1 = 100.1'
�CO2 = 9
GR GRADE
MTI = 92.1'
NO WATER FOUND
86.1' B.O.H.
N. T. S.
ROBERT C COWAN
CE -8801
f::r�..,l��•�
Frown ?V "� n G'� 5—,f ^06
�0 m•th:";fdt(ity 4 /'1 Ajrg7t
On s ►k D ;,/.
inSfiz/��� 9 Se01�iL qS c7wtei 115fville. 4f
-Tf" Wet) 11 Sfq 114d �j S4-5 �'�y,n¢er.hc� $Perms 1 O f�j f �ieS� o F Irl
ql &)1--f. I ttichky
For gi�owi�� r'Je �o �oiJS
O4r5 6�- M
MUNICIPALITY OF ANCHORAGE
Development Services Department
On -Site Water d Wastewater Program
4700 South Bragaw Street
P.O. Box 196650, Anchorage, AK 99519-6650
(907) 343-7904
ON-SITE WASTEWATER DISPOSAL SYSTEM PERMIT
Upgrade
Date Issued: Jun 08, 2006
Expiration Date: Jun 08, 2007
Permit Number: SWO60144 Parcel ID: 050-124-08
Legal Description: WALTER G PIPPEL ADDITION BLK 7 LT 5
Design Engineer: 0003 S & S Engineering Site Address: 016923 EASY ST
Owner Name: PAUL GIBBS Lot Size: 13500 SQ. FT.
Owner Address: 392 N. EKLUTNA Total Bedrooms: 3 Permit Bedrooms: 3
PALMER. AK 99645 -
This permit is for the construction of:
❑✓ Disposal Field [?) Septic Tank ❑ Holding Tank ❑ Privy ❑ Private Well ❑ Water Storage
All construction must be in accordance with:
1. The attached approved design.
2. All requirements specified in Anchorage Municipal Code Chapters 15.55 and 15.65 and the State of Alaska
Wastewater Disposal Regulations ( 18AAC72 ) and Drinking Water Regulations ( 18AAC80 ).
3, The engineer must notify DSD at least 2 hours prior to each inspection. Provide notification by calling
(907) 343-7904 ( 24 hours ). ( Not required for a Water Supply Permit only).
4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather
must be either: A. Open and closed on the same day.
Received By:
Issued By:
B. Covered, sealed, and heated to prevent freezing.
Date:
Date: a 9141
Municipality of Anchorage
.� Development Services Department
Building Safely Division
On -Site Water and Wastewater Program
4700 Bragaw Street
P.O. Box 196650
Anchorage, AK 99519-6650
www.muni.orglonsite
(907)343-7904
ON-SITE SEPTIC/WELL PERMIT APPLICATION
FOR A SINGLE FAMILY DWELLING
N
Property owner(s) Pa U�� gql GI 6bs ,/ Day phone!0 3-07q�
Mailing address 3%� N� Fo;jiNa P l n"4.1 1� Zip Code y._
Site address
Legal description (Sub'd, Block & Lot)
Legal description (Township, Section & Range)
Lot Size 13 .50D Sq. Ft.
THIS APPLICATION IS FOR (®all that apply)
Absorption Field
Septic Tank
Holding Tank
❑
Privy
❑
Private Well
❑
Water Storage
❑
Code CA5_1 q -
K
Number of Bedrooms 3
THIS APPLICATION IS AN:
Initial ❑
Upgrade
Renewal ❑
1 certify that the above information is correct. I further certify that this application is being made for a
Single Family Dwelling�In accordance with applicable Municipal Codes.
S & S ENGINEERING
17034 Eagle River Loop Rood No. 204
r -..i -or,... e1n.b.004;77
(Signature of property owner or authorized agent)
Permit/Rush Fees: i DO � Waiver Fees:
S
Date of Payment: rJ� Dale of Payment:
Receipt Number: Receipt Number:
(Rev. 11/05)
Junel,2006
ROBERT C. COWAN, P.E.
ROBERTA. SHAFER PE-
CMLENGINEERS
(907)694-2979
FAX(907)694-1211
W.&TMALITHORITr MUNICIPALITY OF ANCHORAGE
APR°'ALS Development Services Department
P.O. Box 196650
Anchorage, AK 99519
SEWER i WATER
M"MErSIONS
REFERENCE: Lot 5, Block 7, Walter G. Pippel Subdivision
SEWER&W TER It is requested that you issue a permit to install a new three bedroom septic system to
serve the existing one bedroom dwelling on the referenced property.
A test hole was excavated and a percolation test performed. The approximate location of
EWANEERNGSTUMS the test hole is located on the attached sitelan. At the time of excavation 5/25/06
"REPORTS P ,ground
water was not found. After monitoring, no ground water was found.
We do not anticipate any adverse effects on neighboring wells, septic systems, reserve
WELLNSPECTION areas or drainage patterns b the installation of the
4MUOWTEST g P Y proposed septic system. The
construction of this system will not prevent any future development on any of the adjacent
properties.
SITEPLANS If you require additional information, please contact us.
Sincerely,
ROADCESIGN
Robert C. Cowanv! Pw E
SOL TEST RCMjj
Enclosure
PERCOLATION
TEST
STA ICTLRALA
MECNAMCAI
WSPECTIONS
ONSITE
WASTEWATER
OISP06KSTSTEM
DESIGN
17034 NORTH EAGLE RMER LOOP • SUITE 204 • EAGLE MER, ALASKA 99577
1" = 30'
DESIGN
SITE—PLAN
.'to
7,Al Ir
sr
70
�«
I
• W N A V
CE BRNOM
eco
wZ�Y
a^� I
"lb 00
Z�naC
son
AYhd I
r
Om
C
`n�
a
w
zo
Z O n
m
Clyy
UT
m m
N
N0C).�
ti .\Lt
O£ [rJ
I
m
m
ra">
owe
z
Km
Omti
o
I
_H
iCA
d
O
Tily^w
fin
\
.'to
n
sr
70
�«
4
Zpx
CE BRNOM
_'_
\
sm N II
0
e
FA
I
I /
A e /
10,fill` I /
L
N
PEN
Ln 0L4
'B?ALEL ORIVEWAr
1
EXISTING
0 F m
;
0
CE BRNOM
'0o
sm N II
m
M +
O
C
l✓/ N'A
V c) o
Clyy
UT
LP -
N
N0C).�
ti .\Lt
O£ [rJ
ON
O0'p
m
O
A
Km
Omti
A
A
or
_H
iCA
� \
O
N90
s
m �rn
x0a
O
mj
rN
rin OAS
m£
/°
1
O
m Z C �
nm yZr
•-•
O'
0Oc
0
O
0
n
yD0
t R4O I
C y
ti
ZA
I a
`
zco
m
I
I
I
I
I
Rq
H
FA
I
I /
A e /
10,fill` I /
L
N
PEN
Ln 0L4
a
r
0 F m
SNA
�
r
sm N II
m
M +
O
l✓/ N'A
V c) o
Clyy
UT
LP -
N
N0C).�
^
wtVy
W
O0'p
m
O
A
OCy
A
A
_H
iCA
O
a
m �rn
x0a
O
m
rn
O
m
s O
O
n
�
f)
r
0
3
G"'A
a
r
En
N
I
O)
I
M +
O
wtVy
� m 0
O Z
Y
-! D
A
OCy
_H
iCA
m �rn
x0a
O
d
m
s O
y m A
O
0
G"'A
A%
Municipality of Anchorage d_tENGINE L
Development Services Department W�It,
Building Safety DivisionOnsite Water and Wastewater Program4700 South Bragaw SL
C. COWAN
P.O. Box 196650 Anchorage. AK 99519-6650 % Vic` CE -8801
i
(907) 343-7904
til
Soils Log - Percolation Test i''-�'
Performed For. G 7 FSR, '—'5 Date Performed: ZS
Legal Description: t-orr S LOn"MC'6-ToLwnshtp,Range, Section:
Slope Site Plan
Depth
2-
3-
4
5-
6-
8
10- a
—01?6ATUIGS
6P-Kf MAL-
-
L- Mr -t M c
— E,P .
(ifIXT-
13- W414-
15-
19-
COMMENTS
PERFORMED BY:
PERFORMED IN;
WAS GROUND WATER
A 1
��,
ENCOUNTEI
li
_
S
IF YES. AT WHAT DEPTH?
^
L
O
Depth to Water After
Monitoring?
��
P
E
Date:
1 LIP
-filliillYii11•
al"
��,
�,_■ENM�Vsl
©—■®Wlmval%
l�ss���
.
PERCOLATION RATE I 0-wtevLwnl PERC HOLE DIAMETER
TESTRUNSETWEEN If FT AND FT
S & S ENGINEERING CERTIFY THAT THIS TEST A
111031 E�y4 Div.r tp Rn.d Nn 10,1F
£ G€r"fAi�sA4 �s AND MUNICIPAL GUIDIELINES IN EFFECT ON THIS DATE. DATE: G 11 /o 6
S&
ROBERTC. COWAN. P.E.
ROBERT/- SHAFFR. PF
CML ENGINEERS
(907)694.2979
FAx(907)694.1211
ON-SITE WASTEWATER DISPOSAL SYSTEM
HEALMAUTHOO
La
CONSTRUCTION PRACTICES
and
MATERIAL SPECIFICATIONS
SEWERS WATER
MAW D(TENSKM
REFERENCE: Lot 5, Block 7, Walter G. Pippel Subdivision
June1,2006
SEWER&WANSGECTONTER
GENERAL:
1. The scope of this project includes the installation of a new 1000 gallon HDPE
septic tank, and a new septic trench to serve the existing one bedroom
RE ORIS aE5
residence located on the referencedro e
P P rtY•
2. Construction shall be in accordance with the approved site plan and design
drawings, Municipal permit with any special provisions or conditions, and all
WELLMPECTICN
&FLOW TEST
applicable State and Municipal Wastewater Disposal Regulations.
3. The contractor shall be responsible for obtaining any necessary underground
utility locates.
SITE BANS
4. Unless specifically agreed otherwise, the property owner shall be responsible
for final grading areas subsequently depressed from soil settling.
ROAD DESIGN
5. Contractors installing wastewater disposal systems must be certified by the
Municipal Development Services Department or ADEC if required, for
system installations. Owners installing their own systems must also receive
BOIL TEST
prior approval from the respective agency.
T'ERCC ATION
SEPTIC TANK INSTALLATION:
TEST
1. A septic tank is to be constructed by a certified septic tank manufacturer.
Construction shall include two 4" cleanouts for pumping access.
STRUCRSULS
MECNNYGL
MPECUM
2. The septic tank shall be sufficiently bedded to prevent settling or shifting of
the tank.
ONSITE
WASTEWATER
CISPOSALSYSTEM
CESIGN
17034 NORTH EAGLE RIVER LOOP - SUrrE 204 - EAGLE RIVER ALASKA 99577
fc I u 4-1 1.'; y E S "It-'
)6 9 3
c.=may +>•-�`.�-
AS -BUILT
i
1 hereby certify that 1 have surveyed the following described
property; L -C -f- S. �ioc 1 'T
Mid l/Y/.f-�. 1'i/p i..'tai. ✓✓./
Anchorage Recording Precinct, Alaska, and that the improve-
ments situated thereon are within the property lines and do not
overlap or encroach on the property lying adjacent thereto, that
no improvements on property lying adjacent thereto encroach
on the premises in question and tat there are no roadways,
transmission lines or other visible easements on said property
except as indicated hereon.
Dated at Eagle River, Alaska
this 16r ` day of _A 200 G
ROBERT C. JOMNSON • •N , .
SCALE: Registered Land Surveyor No. g&s
a 99
Box 77-0456, Eagle River, Alaska
Phone (907) 6942513 —
Page 2
Lot 5, Block 7, Walter 6. Pippel Subdivislon
June 1, 2005
3. All standpipes on the septic tank shall extend a minimum of 12 inches above final grade.
4. Septic tanks installed with less than 4 ft. of cover shall be insulated.
5. A foundation cleanout shall be installed one to four feet from the building foundation. in
the line between the tank and the leachfield there shall be two adjacent cleanouts (unless
an effluent pumping system exists within the septic tank). These cleanouts shall be
located on undisturbed soil not more than 10 ft. from the tank. The first cleanout, in line,
shall be to clean toward the leachfield. The second cleanout shall be to clean toward the
septic tank.
6. Final grading over the septic tank shall be such that a positive slope exists away from the
septic tank.
ABSORPTION TRENCH/DRAINFIELD INSTALLATION:
Excavate the proposed trench to the dimensions shown on the design. The bottom of the
excavation shall be within 2 inches of level. If the sidewalls of the excavation become
smeared, they must be raked or scratched (ruffed -up) before gravel (sewer rock)
placement.
2. Once the gravel is installed, the distribution pipe is to be installed level with the
perforations faced downward. Gravel is then to be placed over the distribution pipe to
provide a minimum of 2 inches of cover over the pipe.
3. A silt barrier must be installed between the final gravel layer and the native soil backfill.
Ensure the silt barrier covers the entire gravel surface before placing backfill.
4. Monitor tubes shall be of four (4) inch diameter, installed approximately in the locations
shown on the design, and extend a minimum of 12 inches above final grade. The portion
of the monitoring tube extending through the gravel shall be perforated from the bottom of
the trench to the invert of the distribution pipe. This is equivalent to the effective depth of
the gravel as noted on the design.
5. Backfill over the final gravel layer must not be less than twenty-four (24) inches.
Insulation must be installed when the backfill depth is less than thirty-six (36) inches. The
finish grade over the trench must be mounded to prevent the formation of a depression
after settling.
Pago 3
Lot 5, Block 7, Walter G. Plppol Ubdlvl*lon
Jun* 1, 2000
MINIMUM MATERIAL SPECIFICATIONS:
1. Any septic tank proposed for installation must be constructed by a Municipal approved
septic tank manufacturer.
2. The following pipe materials are approved for use in septic system installations in the
Municipality of Anchorage:
TweofPine Perforated Solid
Cast Iron
Yes
Yes
ASTM D3034 (PVC)
Yes
Yes
ASTM F810 (HDPE)
Yes
No
ASTM D2662 (ABS)
Yes
Yes
Use of a type of pipe other than listed above must be approved by the inspecting engineer.
3. Insulation shall be at least 2" thick extruded direct burial polystyrene (Dow Chemical
Company Styrofoam HI or equal).
4. Septic tank inlets and outlets shall be fitted with watertight couplings (Caulder, Femco, or
equal).
5. A permeable nontoxic silt barrier (Typar 3401, Mirafi 140N, or equal) must be installed
between the final leachfield gravel layer and the native soil backfill.
6. All leachfield gravel (sewer rock) shall be 0.5"-2.5" screened gravel with less than 3%
passing the #200 sieve.
7. When sand is being used as a filter material, its gradation specifications must conform to
current M.O.A. or D.E.C. requirements, which ever requirement applies.
Page 4
Lot S, Block 7, Waiter 0. Pippat Subdivision
June 1, 2006
INSPECTIONS:
Typically there will be a minimum of three (3) inspections required during the installation of the
wastewater disposal system. These inspections will occur as follows:
1. The first inspection must be conducted after the excavation of ditches, pits,
trenches, or beds and before the installation of any gravel. A septic tank may be
set in place, but may not be backfilled before this inspection.
2. The second inspection must be conducted after the placement of the silt barrier,
gravel, distribution lines, standpipes, cleanouts, and insulation, but before the
placement of any other backfill.
3. The final inspection is to occur upon final grading of the property.
Often there will be more than these 3 inspections required. Especially with the installation of
multiple trenches, sand filters, pressurized distribution systems, etc. Thus, the inspecting engineer
is to be contacted at least 24 hours prior to the start of construction. If necessary, a pre -
construction meeting will take place on-site. The inspecting engineer will not coordinate, direct or
control in any way the contractors activities.
The owner shall contract with the contractor to perform the work outlined in these specifications
and plans and in accordance with the attached M.O.A. permit. There will be no contractual
arrangement existing between the contractor and S & S Engineering. S & S Engineering shall be
the owner's representative and will inspect the work as stated above to document the contractors
activities. Final acceptance of the contractors work rests with the owner and the M.O.A.
S & S Engineering shall have no liability to the owner or to others for acts or omissions of the
contractor or any other persons performing work on this project or the failure of the contractor to
carry out the work in accordance with these construction documents. S & S Engineering's
inspecting engineer will not be responsible for the construction means, methods, techniques,
sequence, procedures or the safety precautions incident to this project.
CONTRACTOR/INSTALLER
Aug. 0, 1570
Fedoral housing, Acministration
11.0. Box 130
Anchorago, Alaska ODS01
MULCT: Lot S. Block 7,
Walter G. Pidq)le SubUdikision
Lear Sirs:
This Ucpartmcnt mado on inspection of the subject lot to
determine whether or not 'the lot was large enough fur an
individual on-site water supply and sewage disposal system,
since the proposed building will be a miultifamily dwelling
and somd-public distances for well protectieo radiussmust
be mt.
The lot Was determined to be large enough for these facilities
althouph the present well must be abandonod as it would be im-
possible to get semi-public distances for it. The sewer sys-
tem. must bo located in the Northwest corner of the lot and the
well in the Southeast corner. .
It is anticipated that public sewers will be available to the
subject lot in the roar future.
Sinc:orely,
CLIFFORD P. JUDKINS, R.S.
Administrative Director
BY:
Jrdin R, Lket Re -
T. -Sanitarian
JRL:rn
cc: John Vurecka
76 f'.. B4
1• '� Municipality of Anchorage =
On -Site Water and Wastewater Program
(907) 343-7904 < s , E
Certificate of On -Site Systems Approval
Parcel I.D. 050-124-08 Expiration Date: 746' -
Lot
46O"
1. GENERAL INFORMATION
Lot 5, Block 7, Walter G. Pippel Addition
6923 Easy Street Eagle River, Alaska 99577
Paul Gibbs
Day phone 907-863-0745
PO Box 770446 Eagle River, Alaska 99577
Raney Hardman @ Re/Max Day phone
I] Single Family (wlwo ADU)
❑ Duplex
❑ Multiple Dwellings (Single Family and/or Duplex)
907-440-7257
3. NUMBER OF BEDROOMS:
1, 3
4. TYPE OF WATER SUPPLY:
TYPE OF WASTEWATER DISPOSAL:
Individual Well
El
Individual
FX1
Individual Water Storage
❑
Holding Tank
❑
Community Class Well
❑
Community
❑
Public Water System
❑
Public Sewer
❑
WaiverNarianoe request for:
Received by: Date: —00-1
COSA to be released to the en inee un ss otherwise requested by the engineer.
COSA Fee $ 0 Waiver Fee $
Date of Payment (031 1 Date of Payment
Receipt Number 1 b 1"/� t y Receipt Number
COSA# 05C, INIlopWaiver#
5. STATEMENT OF INSPECTION BY ENGINEER
As certified by my seal affixed hereto and as of the validation date shown below. I verify that my investigation,
based on procedures outlined in the Certificate of Onsite Systems Approval Guidelines for this application,
shows that the on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate
for the number of bedrooms and type of structure indicated herein. I further verify that based on the information
obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water
supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal and State codes,
ordinances, and regulations in effect at the time of installation.
Name of Firm Pinard Engineering Phone 907-232-1347
Address PO Box 871347 Wasilla, Alaska 99687
Engineer's Printed Name Paul E. Pinard, P.E.
6. DSD SIGNATURE 2
I� System #1 Approved for 3 bedrooms
System #2 Approved for
Disapproved
Conditional approval for
bedrooms
Date 3/30/13
bedrooms, with the following stipulations:
By: Pa—Original Certificate Date: ( 1&-1-3
The , nici ity A rage Development Services Division (DSD) issues Certificates of On -Site Systems Approval (COSA) based only
upon the representations given in paragraph 5 by an independent professional civil engineer registered in the State of Alaska. The Municipality
of Anchorage is not responsible for errors or omissions in the professional engineer's work.
7. ATTACHMENTS: = ?
COSA Checklist X Nitrate Advisory w ;_ X
Septic System Advisory Arsenic Advisory
Well Flow Advisory *they ~ h V o l U.0-1
COSA blue sheet r c
If more than 1 septic system is on the lot:
COSA Checklist # + of 1
Structure served by this system
Certificate of On -Site Systems Approval Checklist
Legal Description: Lot 5, Block 7, Walter G. Pippel Addition Parcel ID: 050-124-08
A. WELL DATA
Well type Put If A, B, or C provide PWSID #
Date completed 10/17/12 Sanitary seal (Y/N) Y
Total depth 64 ft. Cased to 64 ft.
FROM WELL LOG
Date of test 10/17/12
Static water level
Well production
WATER SAMPLE RESULTS
35
ft.
20
g.p.m.
Coliform 0 colonies/100 mL Nitrate 6.24 mg/L
Arsenic ND ug/L Date of sample: 2/27/13
Well Log (Y/N) Y
Wires properly protected (Y/N) Y
Casing height (above ground) 18+ in.
AT INSPECTION
3/8/13
39.4 ft.
4
9 -
p.m -Collected by: Pinard Engineering
B. SEPTIC/HOLDING TANK DATA
Tank Type/Material Septic/Steel
Tank size 1000 gal. Number of Compartments 2
Foundation cleanout (Y/N) Y Depression over tank (Y/N) N
Date of pumping 3/14/13 Pumper JRs Pumping
Date installed 7/19/06
Cleanouts(Y/N) Y
High water alarm (Y/N) NA
C. ABSORPTION FIELD DATA
Date installed 7/19/06 Soil rating (g.p.cl ftz or ft2/bdrm) 1.2 gpd/sf System type 5 Wide Trench
Lengthy 40 ft. Width 5 ft. Gravel below pipe 4 ft.
. Total depth ' 7 ft. Eff. absorption area 400 ft, Monitoring tube Y Depression over field N
4 A `e t$$if adequacy test 318/13 Results (Pass/Fail) Pass For bedrooms
Fluid depth in absolution field before test 0 in. Water added 600 gal. New depth 0 in.
El ed Tfine ' � 50 min. Final fluid depth 0 in. Absorption rate >= 150 + g.p,d.
1.
•,,4ny rejuvenation treatment (past 12 mo.) (Y/N & type) None Known
If yes, give date
D. LIFT STATION tJA
Date installed
"Pump on" level at in.
Datum
E. SEPARATION DISTANCES
WELL ON LOT TO:
Septic tank/lift station on lot
Absorption field on lot
Public sewer main
Sewer/septic service line,
Animal containment areas
Size in gallons_
"Pump off' level at
Cycles tested
100'+
100'+
NA
25'+
100'+
SEPTIC/HOLDING TANK ON LOT TO
Ii
Manhole/Access (Y/N) _
High water alarm level at
Meets alarm & circuit requirements?
On adjacent lots 100'+
On adjacent lots 100'+
Public sewer manhole/cleanout NA
Holding tank NA
Manure/animal excrete storage areas NA
Absorption field 101+
Surface water 100'+
Water main 25'+
Driveway, parking/vehicle storage 10'+
F. COMMENTS
Well casing is perforated from 48' to 50', per the well log.
G. ENGINEER'S CERTIFICATION
1 certify that I have determined through field inspections and
review of Municipal records that the above systems are in
conformance with MOA COSA guidelines in effect on this date.
Engineer's Printed Name Paul E. Pinard, P.E.
Date 3/30/13
COSA brown sheet 10-10-12.doc
in.
10'+
10'+
Building foundation
Property line
Water main
25'+
Water service line 101+
Wells on adjacent lots
100'+
ABSORPTION FIELD ON LOT TO:
Property line
10'+
Building foundation 101+
Water Service line
10'+
Surface water 100'+
Curtain drain None Known
Wells on adjacent lots 100'+
Absorption field 101+
Surface water 100'+
Water main 25'+
Driveway, parking/vehicle storage 10'+
F. COMMENTS
Well casing is perforated from 48' to 50', per the well log.
G. ENGINEER'S CERTIFICATION
1 certify that I have determined through field inspections and
review of Municipal records that the above systems are in
conformance with MOA COSA guidelines in effect on this date.
Engineer's Printed Name Paul E. Pinard, P.E.
Date 3/30/13
COSA brown sheet 10-10-12.doc
in.
D. LIFT STATION
Date installed
Size in gallons
Manhole/Access (Y/N)
"Pump on" level at in.
"Pump off' level at
in. High water alarm level at
in.
Datum
Cycles tested
Meets alarm & circuit requirements?
E. SEPARATION DISTANCES
WELL ON LOT TO:
Septic tankllift station on lot
100'+
On adjacent lots 1001+
Absorption field on lot
100'+
On adjacent lots 100'+
Public sewer main
NA
Public sewer manhole/cleanout NA
Sewer /septic service line
25'+
Holding tank NA>i
tt't3
ri
Animal containment areas
100'+
Manurefanimal excrete storage areas
+
/jrea
SEPTIC/HOLDING TANK ON LOT TO:
Building foundation 10'+
Property line
10,+ Absorption field +
Water main 25'+
"
Water service line
10,+ Surface water 100,+
Wells on adjacent lots 100'+
ABSORPTION FIELD ON LOT
TO:
Property line 10,+
Building foundation
10,+ Water main 25'+
Water Service line 1 Q'+
Surface water
100,+ Driveway, parking/vehicie storage
10,+
Curtain drain None Known Wells on adjacent lots 100'+
F. COMMENTS
Well casing is perforated from 48' to 50', per the well log.
G. ENGINEER'S CERTIFICATION
�.a��>�ttttUtry
1 certify that I have determined through field inspections and ` ?, OF -A ,i t
review of Municipal records that the above systems are in
conformance with MOA COSA guidelines in effect on this date. = t}�
Engineer's Printed Name Paul E. Pinard, P.E. _:....i 4.L....... -t{._
3/30113 ....... ............................_...._..
Date PAUL E. PWAIID
�4.�"e „ CE -4793 s
COSA brown sheet 10-10-12.doc
Municipality of Anchorage
Community Development Department
Development Services Division E r.
On -Site Water and Wastewater Program
4700 Elmore Street
P.O. Box 196650 Anchorage, AK 99519-6650
www.muni.org/onsite
(907) 343-7904
Nitrate Advisory
Certificate of On -Site Systems Approval # 131118
A Certificate of On -Site Systems Approval inspection and test of potable
water was recently conducted on the well water supply on Block 7, Lot 5 of
Walter G. Pippel Addition subdivision. This inspection revealed a nitrate
concentration of 6.24 milligrams per liter (mg/L) was reported for the
property's well water sample. The Environmental Protection Agency (EPA)
has established a maximum contaminant level (MCL) of 10.0 mg/L for
public drinking water systems. While private wells are not subject to this
regulation, EPA standards are based on existing health information and can
therefore be used to gauge the relative quality of water from private wells.
Please see the attached "Nitrate Fact Sheet" for important information
regarding nitrate.
This advisory must be attached to all copies of the subject Certificate of On -
Site Systems Approval.
100.00' N890 57'00T
cacao
N�wla waxT
maxi .AeNe eslercx
a.awc sElm«
C.o.$ N
o GARAGE
0
b
o
o
LTI
LO
m
4 m
6
EXISTING
HOUSE 29"
N
O
O O
,Fyl,
Ca
0
0
T2.D
ID
0
CANT
o
o
0
0
�
WELL
0
00.00' N890 57'00"E 100.00' N890 57'00"E
N EASY STREET
UNDER NO CIRCUMSTANCES SHOULD AN AS-BUILT BE USED FOR CONSTRUCTION OR FOR ESTABLISHING BOUNDARY OR FENCE LINES.
THE SURVEYOR TAKES RESPONSIBILITY FOR THE INITIAL TRANSACTION ONLY AND ASSUMES FINANCIAL LIABILITY ONLY FOR THE COST OF THE SURVEY.
LISTED DISTANCES PREVAIL OVER SCALING REPRODUCTION MAY CAUSE ERRORS IN SCALE.
Lj LW "WY SURVEY TYPE
SYMBOLS
❑ FOW"TON AS-9WT
• SET REBAR DRAINAGE ASPHALT
❑ RNM. SWUCTURE A WILT
❑ AS-BUILT LOT "WY TOPOGRAPHY
�� WOOD FENCE ....
0 FOUND REBAR" CONCRETE
PIAT PLAN ... ... ...
Ognl ASSUMED ELEV. IL--71—IF METAL FENCE ® WOW DECK
AS- T CWHM SET rl RECERWIGAVok w5 ALT ... W CORNERS
...NO
PLOT PLANS & LOT SURVEYS
NOTE:
IT IS THE RESPONSIBIUTY OF THE BUILDER OR OWNER, PRIOR TO
ONLY THOSE IMPROVEMENTS ABOVE GROUND AND VISIBLE WILL BE
CONSTRUCTION, TO VERIFY PROPOSED BUILDING GRADE RELATIVE
SHOWN. FENCES, WELLS, SEPTIC CLEANOUTS, SIDEWALKS, DRIVEWAYS,
TO FINISHED GRADE AND UTILITY CONNECTIONS AND TO DETERMINE
ETC., ARE SHOWN IN THEIR APPROXIMATE LOCATION, ONLY. SNOW
THE EXISTENCE OF ANY EASEMENTS, COVENANTS OR RESTRICTIONS
MAY PREVENT SOME IMPROVEMENTS FROM BEING SEEN AND LOCATED.
WHICH DO NOT APPEAR ON THE RECORDED SUBDIVISION PLAT.
ALL DISTANCES ARE RECORD UNLESS OTHERWISE NOTED.
SURVEY CERTIFICATION
Oil
*0 Oil
.•-�E OF••�y
Prepared by
Robert E. Johns, Jr. & Assoc.
PLOT PUN
iA..er wrWr urtln.w lA,waar «Awws
ew xL .,., a,e rr er n.e.n. as a. I
�`P,..• ,••j
�.
Professional Land Surveyors
Ica. AW s.waelYMa a a M xe oemo
�• •� iyy
1700 Brink Dri".
ANCHORAGE. ALASKA 99504
a %
I
Scale: n _ I
30
Rea. Lot S.F.
Rec. Plat FUe No.
=
FOUNDATION AS-BUILT
•••••r••
Checked b
6 Rxxrl c iew,e
a
+caTnus
.(`.•p••�/:,
... ..•••••• .
Dale Surveyed:
03/04/13
rawr REJ
JYK
+aw'e.ial'.mW
°
•....•
ERT E.J SJR.
on:
03/04/13
Grid:NW252
WD13-72Dale
FINAL STRUCTURE AS-BUILT,
•.a✓•%
•' <01-
Legal Description:
».:°l : «»'
���a� •................,•na5:�•
LOT 5 BLOCK 7
w10„•.,w.wAs,w'.ue1w1rL ,."moi.
+/,,,Tesstonot
WALTER G PIPPEL ADDITION
;����•
LOCATION: Lot 6, Block 7, Walter G. Pippel Addition
DRILLER: Sullivan Water Wells
DATE WELL COMPLETED: 10/17/12
WELL DEPTH: 64'
STATIC WATER LEVEL (top of casing): 39.4'
PINARD ENGINEERING
P.O. Box 871347
Wasilla, AK 99687
(907) 357-ENGR (3647)
WELL FLOW TEST
JOB NUMBER: 13-039
DATE OF TEST: 318/13
FIELD STAFF: PJ Pinard
1�1
Time
Elapsed
Time
(Minutes)
Static
Water
Level
Flow
Rate
m
Cumulative
Gallons
Pumped
Remarks
2:35 PM
-
39.4'
4.0
- I Start Test - Meter
569320
2:50
15
39.4'
4.0
60
569380
3:05
30
39.4'
4.0
120
569440
3:20
45
39.4'
4.0
180
569500
3:35
60
39.4'
4.0
240
569560
3:50
75
39.4'
4.0
300
569620
4:05
90
39.4'
4.0
360
569680
4:20
105
39.4'
4.0
420
569740
4:35
120
39.4'
4.0
480
569800
4:50
135
39.4'
4.0
540
569860
5:05
150
39.4'
4.0
600
569920
5:20
165
39.4'
4.0
660
569980
5:35
180
39.4'
-
720 Stop Test
570040
RECOVERY
L All well protection features are adequate.
Recovery measurements are not necessary.
Average Flow Rate: 4.0 gpm
Comments: DURING THIS TEST, THIS WATER SUPPLY WELL WAS CAPABLE OF
PRODUCING 4.0 GPM. THIS TEST DOES NOT CONSTITUTE A
WARRANTY OR GUARANTEE THAT THE WATER SUPPLY SYSTEM
WILL CONTINUE TO FUNCTION AND PRODUCE AT THIS RATE.
Reviewed by: Paul Pinard
Date: 3/18/13
_ PINARD ENGINEERING
; 21- I
h P.O. Box 871347
Wasilla, AK 99687
(907) 357-ENGR (3647)
ADEQUACY TEST
LOCATION: Lot 5, Block 7, Walter G. Pippel Addition
APPLICANT: Paul Gibbs
PO Box 770446
Eagle River, Alaska 99577
SEPTIC TANK TYPESIZE: Steel/1000 Gallons, per MOA Records
ABSORPTION SYSTEM: 5 Wide Trench, per MOA Records
DAILY FLOW:
1 BEDROOM x 150 GAL/BR = 150 Gallons
TEST DATA
JOB NUMBER: 13-039
DATE OF TEST: 318113
FIELD STAFF: PJ Pinard
NUMBER OF BEDROOMS: 1
SCUM: 0.1' SLUDGE: 0.4'
NEEDS TO BE PUMPED: Yes XX No
CURRENTLY IN USE: Yes XX No
Time
Flow
Rate
Volume
Cumulative
Volume
Septic Tank
Septic
Tank
Soil Absorption System
Comments
pM
(GPM)
(GALS)
(GALS)
Liquid Level
A Level
Monitor
Tube 1*
A SAS
Level
Monitor
Tube 2*
A SAS
Level
3:05
4.0
-
-
4.0'
-
0.0'
-
Start Flow -Meter 569440
3:20
4.0
60
60
4.1'
0.1'
0.0'
0.0'
569500
3:35
4.0
60
120
4.1'
0.0'
0.0'
0.0'
569560
3:50
4.0
60
180
4.1'
0.0'
0.0'
0.0'
569620
4:05
4.0
60
240
4.1'
0.0'
0.0'
0.0'
569680
4:20
4.0
60
300
4.1'
0.0'
0.0'
0.0'
569740
4:35
4.0
60
360
4.1'
0.0'
0.0'
0.0'
569800
5:05
4.0
120
480
4.1'
0.0'
0.0'
0.0'
569920
5:35
-
120
600
4.1'
0.0'
0.0'
0.0'
Stop Test - 570040
Date I Time SAS MT1 SAS MT2
*ALL MEASUREMENTS IN FT.
TEST: PASSED XXX FAILED
COMMENTS: This system was found to be operating satisfactorily. There was no measurable liquid in the SAS MTs
prior to or at any time during the test.
Reviewed by: Paul Pinard
Date: 3/18/13