Loading...
HomeMy WebLinkAboutTHE TABLELANDS BLK 4 LT 7The T bl lands Block 4 Lo? 7 #0§ 1 - 80 ! - 1 §  Municipality of Anchorage Development Services Department Building Safety Division On-Site Water & Wastewater Program, 4700 Bragaw P.O. Box 196650 Anchorage, AK 99519-6650 www.ci.anchorage.ak.us (907) 343-7904 Page 1 of On-Site Wastewater Disposal System and/or Well Inspection Report Permit Number: OSP1 1 1007 PID Number: 051--801 --15 Nome: MICHAEL & CHRISTINA WALLJASPER WastewaterSystem: [] New · Upgrade Address: 22974 WHISPERING BIRCH DRIVE *CHUGIAK, AK 99567 ABSORPTION FIELD Phone: No. of Bedrooms: (907) 210-826-401 5 4 · Deep Trench [3 Shallow Trench [] Bed []Mound []Other LEGAL DESCRIPTION so, Roting: 0045 GPD/Sq. Ft. Total Depth f ..... 9 MAXigln°l grade: Ft. Block: Lot: Subdivision: Depth to pipe bottom from original grade: Grovel depth beneath pipe: 4 7 THE TABLE LANDS 4.85 MAX rt. 4.15 Ft. Township: Range: Section: Fill added above original grade: Grovel length: SEE DWG. rt. 68 rt. WELL: [] Ne~ ~/~[] Upgrade~/~ Gravel width: 5 Ft. Number of 111 .... Dist .... __between Il .... Ft. ClosslficaUon (Private A,B C' Total Dept · Cased To' , ,~: ~,.~ tal Dept~j:~--~ '(BEDROCK) Total absorptlo ...... Pipe material: ,., .n_t,~'"' ,r'" /- . D 50,34/ F-810 , ~ ~-,~ .~.. ~,~ \ ~ / Ft. Ft. 680 SQ. Ft. Driller:. "~" ~~ Dote Drilled: StoUc Water Level: Installer: Date installed: ~~ Ft. WILCO CONTRACTORS 2/3/11 ~e'd: GPM I Set At: Ft. II0°slng Height Above G .... Ft.d: TAN K SEPARATION DISTANCES []Septic [] Ho,ding O S.T.~.P. ~ []Other*  Manufocturen G Capacity in gallons: TO Septic Absorption Lift Holding Public/Private Tank Field StoUon Tank Sewer Lines n Well -- 200'+ -- -- 25% ~ Number of comportments: Surface Water -- 100'+ .... LIFT STATION Lot Line -- 10'-t- _ _ _ size in gallons: I Manufacture~. I Foundation -- 10'-I- -- -- -- 'Pump on" level at: 'Pump off' level at: High water alarm at: Pump Make Ar Model: Electrical inspections performed by: Curtain Drain .. NONE KNOWN I Remarks: TWO BEDROOM TRENCH BENCH MARK LocaUon and Description: BOTTOM OF SIDING SE HOUSE CORNER Assumed Elevation: 104.91 Ft. ENGINEER'S SEAL Inspections performed by: G EG, Ltd. Dates: 1st 2/,3/~ ~ 2nd 2/5/11 ~ OF Development Services Department Approval ~i~~~ 4 - Reviewed and approved by: ,~?/..~"_ ..,~' /~/--'o~ Date:.~. - z¢ - [] u¥,.,..~ PERMIT NUMBER: PARCEL ID NUMBER: OSP111007 051-801-15 AS-BUILT DRAWING / / / / / / THE TABLELANDS BLOCK 4 LOT 6 / / ' "¢':.: i'" ":'" / / / / EXISTING 1250 GALLON TANK SPLITTER EXISTING 4 BEDROOM HOUSE I I I I RESERVE SITE REQUIRE ADVANCED TREATMENT. EXISTING DRAINFIELD ALL SURROUNDING LOTS ARE SERVED BY PUBLIC WATER THE TABLELANDS BLOCK 4- LOT 8 GEG TH#I A B DBL1 57.87 16.95 DBL2 58.45 18.02 FS 59.41 19.85 CO 59.82 21.55 CO1 90.60 65.80 MT1 91.00 68.17 C02 94.65 105.10 MT2 95.88 105.99 2 BEDROOM DRAINFIELD C01 MT2 C02 50+ FEET 25%+ 25%+. 25%+. 1" = 40' 25%+ GARNESS ENGINEERING GROUP, Ltd. CONSULTANTS & GENERAL CONTRACTORS 3701 E TUDOR ROAD, SUITE 101 * ANCHORAGE, AK 99507 * PHONE (907)337-6179 * FAK (907)338-5246 * WEBSITE: www.gamessengineering.com PREPARED FOR: PHONE NUMBER: MICHAEL & CHRISTINA WALL JASPER 210--826--4015 LEGAL DESCRIPTION: THE TABLELANDS S/D; BLOCK 4, LOT 7 PAGE NUMBER: 20F5 ID[~WN BY: DATE: P N B 2/4/2011 TYpe OF WORK: ASBUILT DRAWING (Rev, 01/05) AS BUILT DRAWING OSP111007 - 051-801-15 GEG TH FILTER FABRI( MT CO FINAL GRADE = 95.64+ ORIGINAL GRADE @ HIGHEST POINT= 95410 INVERT OF PIPE = 90.25 BOTTOM OF TRENCH = 86010 'E ELEVATION OF BOTTOM OF TESTHOLE= 80.10 (DRY) GA iR'NESS E NG I NiEE lq liNG G R.O'UP, iLtd. CONSULTANTS & GENERAL CONTRACTORS 3701 F. TUDOR ROAD, SUITE 101 * ANCHOR~GE, AK 99507 * PHONE (907)337-6179 * FAX (907)558-3246 * WEBsrrE: vrew.game~englneering.com PREPARED FOR: I PHONE NUMBER: MICHAEL & CHRISTINA WALL JASPERI 210-826-4015 LEGAL DESCRIPTION: THE TABLELANDS S/D; BLOCK 4, LOT 7 PAGE NUMBER: 30F3 DRAWN BY: PNB 'PfPE Of WORK: DATE: PROFILE DRAWING 2/4/2011 (Rev. 01105) Permit Number: Tax Code'Number: Work Type: On-Site Wastewater Disposal System Permit 'OSPl11007 05180115000 Septic MUNICIPALITY OF ANCHORAGE Development Services Department On-Site Water & Wastewater Program 4700 EImore Road, PO Box 196650 Anchorage, AK 99519-6650 Telephone: (907) 343-7904 Upgrade Permit Effective Dates: January 25, 2011 to January 25, 2012 Design Engineer: GARNESS ENGINEERING GROUP LTD Subdivision: THE TABLELANDS Site LegalAddress: THE TABLELANDS BLK 4 LT 7 G:1559 Owner/Address: GARNESS ENGINEERING GROUP LTD 3701 E TUDOR RD STE 101 ANCHORAGE AK 99507 Site Mailing Address: 22974 WHISPERING BIRCH DR, Chugiak Lot Size in Sq Ft: 40000 Total Bedrooms: 4 This permit is for the construction of: Y Disposal Field N SepticTank N Holding Tank N Privy N Private Well N Water Storage All construction must be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80). 3. The wastewater code requires inspections during the installation. The engineer must notify the Development Services Department at least 2 hours prior to each inspection. Provide notification by calling (907) 343-7904 (24 hours). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must either: A. Open and Close on the same day. B. Covered, sealed, and heated to prevent freezing. Special Provisions: 1. Construction may proceed at your own risk before the 7 day water monitoring is complete. Please submit stamped and signed results with the As-built Inspection Report. If the results require a design change, construction of the system will stop pending On-Site review and approval. MUNICIPALITY OF ANCHORAGE Community Development Department Development Services On-Site Water & Wastewater Program Phone: 907-343-7904 Fax: 907- 343-7997 Mayor Dan Sullivan On-Site Sewer/Well Permit Application For A Single Family Dwelling Parcel I,D. ~...~' ( - ~;~0 ~ -"/~ Property owner(s) MICHAEL & CHRISTINA WALLJASPER Day phone Mailing address 22974. WHISPERING BIRCH DRIVE *CHUGIAK, AK 99567 210-826-4015 Site address 22974 WHISPERING BIRCH DRIVE *CHUGIAK, AK 99567 Legal description (Sub'd, Block & Lot) THE TABLELANDS; BLOCK 4, LOT 7 Legal description (Township, Section & Range) Lot Size ~ O~O00 Sq. Ft. NUmber of Bedrooms 4 THIS N/A THIS APPLICATION IS FOR: ( [] all that apply) Absorption Field · Septic Tank [] Holding Tank [] Privy [] Private Well [] Water Storage [] THIS APPLICATION IS AN: Initial [] Upgrade · Renewal [] APPLICATION INCLUDES A VARIANCE/WAIVER REQUEST FOR: I certify that the above information is correct. I further certify that this application is being made for a Single Family Dwelling and is in accordance with applicable Municipal codes. GARNESS ENGINEERING GROUP, Ltd. (Signature of property owner or authorized agent) Permit/Rush Fees: ~' Date of Payment: Receipt Number: Permit No. 05 F Waiver Fees: Date of Payment: Receipt Number: Waiver NOG (Rev. 01/11) GARNESS ENGINEERING GROUP, Ltd. CONSULTANTS & GENERAL CONTRACTORS January 26, 2011 Municipality of Anchorage Development Service Department On-Site Water & Wastewater Program 4700 Bragaw Street P.O. Box 196650, Anchorage, Ak 99519-6650 (907) 343-7904 Ref: Revisions to Permit Number OSPlll007 for a Septic System Design Upgrade for The Tablelands Subdivision; Lot 7, Block 4 To whom it may concern: Per the special provision of the referenced permit, we excavated a test hole on the property. Our first attempt at excavating a test hole near the reserve drainfield site, we found that buried debris and organics were encountered which made this area not suitable for installing the new drainfield. We then excavated a test hole further downhill and found suitable soils. Attached is a soils log which shows the sols classification and the percolation test data. The percolation rate was found to be 48 minutes/inch. Based upon our septic adequacy test, the existing drainfield has absorption capacity of 313 gpd and is adequate for 2 bedrooms. Since the house is a 4 bedroom residence, we are proposing that a 2 bedroom upgrade be installed around the 30 foot radius of our test hole. A flow divider will be installed after the tank and double cleanouts which will evenly split the flow between the existing drainfield and the new drainfield. Attached is the revised design drawing will shows the new design criteria. The drainfield is to be installed at the base of a 25-35% slope and the slopes downhill from the drainfield are a 15 to 25% running approximately west to east. Over 50 feet downhill from the drainfield, the slopes increase to over 25 percent. In short, there are no slope concerns with this installation. We request that the permit be revised to accept the new drainfield location and design criteria. We are unaware of any adverse impacts this installation would have on adjacent wells or septic systems. If you have any qu~ions, please contact us at 337-6179. Thank you for your assistance. , P.E., M.S. Pres~ 3701 E. Tudor Road, Suite 101 * Anchorage, AK 99507-1259 Ph: (907) 337-6179 * Fax: (907) 338-3246 * Website: www.garnessengineering.com GAR.NESS ENGINEERING GROUP, Ltd. CONSULTANTS & GENERAL CONTRACTORS January l8,2011 Municipality of Anchorage Development Service Department On-Site Water & Wastewater Program 4700 Bragaw Street P.O. Box 196650, Anchorage, Ak 99519-6650 (907) 343-7904 Ref: Proposed Septic System Upgrade for The Tablelands; Lot 7, Block 4 To whom it may concern: The existing 4 bedroom house is served by public water and a private septic system. The system was installed in 2006 and is in a state of failure and needs to be upgraded. We are proposing to install the 5-wide reserve site and utilize the existing 1250 gallon septic tank. The tank is less than 5 years old, so it is reasonable to assume that the integrity of the tank has not been compromised. There are two test holes filed with your department. The drainfield will be designed around the 30 foot radii of these test holes. Comments regarding the design are summarized as follows: 1. SOILS: See the attached logs which show the soil classifications, groundwater monitoring, and the percolation test results. 2. DRAINFIELD DESIGN: See attached design drawing for drainfield specificationso 3. SURFACE WATERS: There are no surface water concerns. 4. TOPOGRAPHY: The average topography below the drainfield is a 20 percent slope running approximately northwest to southeast. We are unaware of any adverse impacts this installation would have on adjacent wells or septic systems. If you have any qu,estig~s, please contact us at 337-6179. Thank you for your assistance~ ,S/~ely~ /, ~ · 5effr~(y A .... t~/4ess,? Prestde~t~ x,..~ NOTE: Attached is the design drawing which is part of the design package for this septic system (Contact G.E. G. Lid. for 7page construction specification letter.) 3701 E~ Tudor Road, Suite 101 * Anchorage, AK 99507-1259 Ph: (907)337-6179 * Fax: (907)338-3246 * Website: www.garnessengineering.com GARNESS ENGINEERING GROUE Ltd. CONSU!LTANTS & GEN EP, AL CONTRACTORS January 10, 2011. Michael & Christina Walljasper 22974 Whispering Birch Drive Chugiak, AK, 99567 REFERENCE: The Tablelands; Block 4, LOt 7; 22974 Whispering Birch Drive, Chugiak, AK: Septic System Adequacy Test, and Upgrade Proposal for a Septic System Serving a Single Family Residence within the Municipality of Anchorage (MOA). Mr. & Mrs. Walljasper, Per your request, we inspected the septic system, which serves the subject property for the purpose of obtaining an MOA Certificate of Onsite Systems Approval (COSA). Our findings are summarized as follows: SEPTIC SYSTEM: The septic system consists of'a 1250 gallon septic tank a trench type drainfield. The system had been vacant for over 30 days and required an initial pre-soak. On 1/6/2011 the drainfield was inspected and found to be dry. Over a period of 395 minutes, a total of 2600 gallons of water was introduced into the system raising the water level in the monitoring tube 2 inches above the invert of the distribution line. The following day the drainfield was inspected and the water level had dropped 8 inches below the invert. Water was introduced into the system for a second time to test the drainfield. Over a period of 90 minutes a total of 630 gallons were introduced into the system which caused a rise in the monitoring tube of 8 inches~ right to the invert of the distribution line. After monitoring the drainfield for 1085 minutes the liquid level had dropped 3 inches in the monitoring tube. This corresponds to an absorption rate of 313 gallons per clay. Based upon this data, it was determined that the drainfield does not meet the MOA absorption requirement of 600 GPD. Althoug~ the system may continue to be functional, a new septic system will need to be designed .and installed prior to transferring title on the house. The following is a summary of the engineering costs associated with upgrading the septic system. · Services to date for the records research, pre-soak, septic test, and preparation of this report: $1150.00 · Engineering ser, Tices to desiD~ the septic system: $420.00*. This is based upon a conventional gravity flow septic system with no waivers to property lines, surface waters, or nearby wells. We intend to use the test hole data on file at the Municipati_s:y of Anchorage for desig-n purposes. · M.O.A. sewer upgrade permit: $530.00* Payable to the M.O.A. · Engineering services to inspect the installation of the septic system and prepare as- built drawings, assuming a conventional gravity flow septic system with a single trench/bed and no sand filter: $900.00.. Upon request, we can provide you with our standard rate sheet, which lists the inspection costs for other types or configurations of septic systems. This information is also available on our website at 3701 E. Tudor Road, Suite 101 * Anchorage, Alaska 99507-1259 Ph: (907) 337-6179 * Fax: (907) 338-3246 * Website: www.garnessengineering.com garnessengineering.com. The items marked with an asterisk must be paid prior to submitting the design package to the Municipality' of Anchorage. For your convenience, we accept all major cretiit cards. The cost for the excavator to perform the installation is un'known at this time. After the soils testing and design have been completed, we will provide you with a bid for the septic installation. Upon completion of the installation we will need to prepare the MOA Certificate of Onsite Systems Approval paperwork and deliver it to the MOA. The MOA will charge $250.00 to process the COSA. If you have any questions, please contact us at 337-6179. For more extensive information on septic system testing and design, see our website at www.gamessengineering.com. We look forward to assisting you with your engineering needs, and will do our best to provide a cost effective solution. Sincerely, U.S. 3701 E. Tudor Road, Suite 101 * Anchorage, Alaska 99507-1259 · Ph: (907) 337-6179 * Fax: (907) 338-3246 * Website: www.garnessengineering.com CO- ( DESIGN CRITERIA: NUMBER OF BEDROOMS: 2 BDRM uPGRADE GALLONS PER DAY (GPD): .300 PERCOLATION RATE/S: 48 PROPOSED APPLICATION RATE: 48 MINIMUM DRAINFIELD SQ.FT.: 66'7 DRAINFIELD DESIGN: MAXIMUM DEPTH: 9 FEET MAXIMUM WIDTH: 5 FEET LENGTH: 67 FEET M.O.A. APPROVED SAND FILTER: N/A EFFECTIVE: 4 FEET REDUCTION FACTOR: 0.50 ACTUAL SQ.FT.: 670 GEG, Ltd. HAS A 7 PAGE SPECIFICATION LETTER THAT PERTAINS TO THIS DESIGN. TO OBTAIN A COPY OF THE LETTER CONTACT GEG. BY PROCEEDING FORWARD WITH THIS INSTALLATION, THE ENGINEER, WELL DRILLER, CONTRACTOR AND PROPERTY OWNER AGREE THAT THEY HAVE READ THESE SPECIFICATIONS AND AGREE TO ACCEPT THE TERMS AND CONDITIONS OUTLINED. THE TABLELANDS BLOCK 4 LOT 6 EXISTING 1250 GALLON SEPTIC TANK TO STAY UNINTERRUPTED AND USED PROPOSED EXISTING BEDROOM HOUSE ~/°KEY /' ALTE REQUIRE ADVANCED ~ EXISTING D~NFIELD. SEPTIC ADEQUACY TEST FOUND TO ABSORB 315 GPD. SIZED FOR 2 BEDROOMS-- APPROXIMATE AR~ OF BURIED FILL/DEBRIS (STUaPS). SCALE: GEG TH~I I THE T~LE~NDS BLOCK 4 LOT 8 1"=40' ALL SURROUNDING LOTS ARE SERVED BY PUBLIC WATER ALT. SITE DESIGN CRITERIA: NUMBER OF BEDROOMS: 4 GALLONS PER DAY (GPD): 600 PERCOLATION RATE/S: 4 TO 48 PROPOSED APPLICATION RATE: 2.0 MINIMUM DRAINFIELD SQ.FT.: 500 DRAINFIELD DESIGN: MAXIMUM DEPTH.'~J FEET MAXIMUM WIDTH: 5 FEET .~."'~. LENGTH: .30 FEET M.O.A. APPROVED SAND FILTER: N/A EFFECTIVE: 4 FEET REDUCTION FACTOR: 0.50 ACTUAL SO.FT.: .300 DOUBLE CLEANOUTS ARE TO BE REMOVED AND NEW DOUBLE CLEANOUT AND FLOW DNIDER ARE TO BE INSTALLED. CO MUST BE MAINTAINED AT BEGINNING OF EXISTING TRENCH I~5~ 2 BEDROOM DRAINFIELD UPGRADE 25%-30% 25%-30%. 15%-25%. FEET- 15%-25~,. 15~-25%. 25%+,. 25~+~ 25% +, 25~+. CHANGE IN GARNESS ENGINEERING GROUP, Ltd. CONSULTANTS & GENER. AL CONTRACTORS lB. TUDOR ROAD, SUITE 101 · ANCHORAGE:, AK 99507 · P~ON~' (907)337-6179 * FAX (907)338-3246 · WEBSITE: w~n~.gamessengineer;ng.com PREPARED FOR: I PHONE NUMBER: I PAGE NUMBER: MICHAEL & CHRISTINA WALLJASPER J 210-826-4015 J 1 OF 1 LEGAL DESCRIPTION: I DRAWN BY: THE TABLELANDS S/D; BLOCK 4, LOT 7 I J.L.M- TYPE OF WORK: IDATE: REVISED DESIGN OF SEPTIC SYTEM UPGRADE I 1/26/2011 GARNESS ENGINEERING GRO~ Ltd. ~ CO"SULTANT~,& GENERAL CONTRACTORS ...... 3701 E. TUDOR ROAD, SUITE 101 ' ANCHORAGE. AK. 99507 ~ONE: (907)337-6179 · FAX: (907).~..x~-3246 · WEBSITE: gorn~mjin~ering.co~ I ]SOIL LOG - PERCOLATION TEST] ORGANICS/ FILL GM TO SM WITH LENSES OF ML (HARDPAN) SOIL CLASSIFICATIONS GW GP GN GC SW SP SM SC ORG ML CL OL MH CH OH DEPTH TO GROUNDWATER DATE DRY 1/25/2011 SEE ATTACHED DESIGN DRAWING DATE READING CLOCK NET TINE WATER LEVEL NET DROP TIME (MINUTES) READING (INCHES) 1/25/2011 1 - _ 6,, _ 2 - .30 5-3/8" 5/8" .3 - _ 6- _ 4 - 30 5-3/8" 5/8" 5 - _ 6- _ 6 - 30 5-3/8" 5/8" PERCOLATION RATE 48 (HIN./INCH) PERC. HOLE DIA. 6 (INCHES) SOILS LOGGED BY: COMMENTS: TEST RUN BETWEEN 6.0 FT. AND 6.5 FT. A FOUR HOUR PRESOAK WAS PERFORHED: · YES ROB CAMPBELL PERCOLATION TEST PERFORHED BY: E~]NO JODY MAUS PERFORMED BY GEG, Ltd. I, ,JEFFREY A. GARNESS, CERTIFY THAT THIS WAS PiERFO~,MED IN ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE:  Municipality of Anchorage :-' Development Services Department Building Safety Division ~. On-S~te Water and Wastewater Program, 4700 Bragaw St. P.O. Box 196650 Anchorage. AK 99519~650 Page / of..~ www ci.anchorage.ak.us (907) 343-7904 ON.~qrrE WASIEWATER DISPOSAL SYSTEM AND/OR WELL INSPECTION REPORT Permit Number: Sw06o15o PID Number: ~ SPINELL HOMES, INC. Wastewater System: [] New D Upgrade 1900 W. NORTHERN LIGHTS BLVD, SUITE 200 ABSORPTION FIELD 344.5678 4 G~'r~ n sha~,~,,T~m 13~ed LEGAL DESCRIPTION 1.o G,~ s ~,. ~ 4 L~ 7 S~,x~,~: THE TABLELANDS 3.5 ~. 4 Ft 1+ r~. 61 F~. Well: j(J/~ DNew r']Upgrade 5 .. ""'"", N/A Ft. ~t 610 F~ PVC 3034 Ft PISANO 6/28106 GPM FL F~- TANK SEPARATION DISTANCES [] Septic [] Hold,ng [] S.T.E.P. [] Other: w~ N/A N/A N/A N/A N/A STEEL 2 ~S~eW~ 100'+10.. 100'+10,+ N/AN/A N/AN/A V ~' N/A . .~,~.LIFT STATION /~'/4 Founda~ 5' + 10' + N/A N/A ~ "'"'"~ BENCH MARK REAR DOOR SILL 100 Ft Inspections performed by: NORTHRIM ENG. Dates: 1" 6/23/06 _~ ,, 2'~ 6/20/06 Development Services Department Approval Conditional Approval Date: Reviewed and approved by: Date: ~ I~J ~1~__ u o Z m,m Ld EERING MEMO Steve Eng, PE, PH P.O. Box 770724, Eagle River AK 99577 (907) 694-7028 tel NorthRimEng~aol.com Date: 12/5/06 Number of Pages: 3 To: Joe Goodall/Jeff Poet MOA On-Site Services Subject: The Tablelands, B4 L7, B4 L12, & B5 L1 Comment Sheets Joe & Jeff, This is in reply to the three comment sheets. The steepest slope was measured downslope ofthe constructed trench & the replacement trench. Analysis was conducted in accordance with the 4/17/04 guidance by James Cross, PE. A profile was drawn with the existing ground slope, the 25% slope line and a line intersecting a point 2.5' above the system extended to the existing ground at a 35' distance. The Tablelands, B4 L7: The existing ground dips over 25% at a distance of 15'to 29' from the replacement trench. The overall slope stays above the 25% line. The slope ofthe line 2.5' above the system is ~17%. The Tablelands, B4 LI2: The existing ground dips over 25% at a distance of 25' from the replacement trench. The overall slope dips below the 25% line at a distance of 30' from the replacement trench. The slope of the line 2.5' above the system is (~ 21%. The Tablelands, B5 LI: The existing ground dips over 25% at a distance of 22' from the constructed trench. At this distance a cut-bank is present. This cut-bank requires grading to less than a 25% slope. Spinell Homes Inc. requests that a conditional approval be granted in order for the work to be completed next construction season. Thanks-Steve 0 -~ ocr OW m, ~'0 C Z W T <E (._) I-- W MUNICIPALITY OF ANCHORAGE Development Services Department On-Site Water & Wastewater Program 4700 South Bragaw Street P.O. Box 196650, Anchorage, AK 99519-6650 (907) 343-7904 ON-SITE WASTEWATER DISPOSAL SYSTEM PERMIT Initial Date Issued: Jun 12, 2006 Expiration Date: Jun 12, 2007 Permit Number: SW060150 Legal Description: THE TABLELANDS BLOCK 4 LOT 7 Design Engineer: 0838 NORTH RIM ENGINEERING Owner Name: SPINELL HOMES, INC Owner Address: 1900 W. NORTHERN LIGHTS BLVD #2[ Total Bedrooms: 4 ANCHORAGE, AK 99517- Parcel ID: 051-801-15 Site Address: 22974 WHISPERING BIRCH DRIVE Lot Size: 40000 SQ. FT. Permit Bedrooms: 4 This permit is for the construction of: [] Disposal Field [] Septic Tank [] Holding Tank [] Privy [] Private Well [] Water Storage All construction must be in accordance with: 1. The attached approved design. 2. Ail requirements specified in Anchorage Municipal Code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations ( 18AAC72 ) and Drinking Water Regulations ( 18AAC80 ). 3. The engineer must notify DSD at least 2 hours prior to each inspection. Provide notification by calling (907) 343-7904 ( 24 hours ). ( Not required for a Water Supply Permit only ). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must be either: A. Open and closed on the same day. B. Covered, sealed, and heated to prevent freezing. 5. The following special provisions. ENGINEER TO SHOW ON THE AS-BUILT INSPECTION THAT THE SUBSURFACE DISPOSAL FIELD AND ALTERNATE SITE IS A MINIMUM 50' UPHILL FROM A SLOPE 25% OR GREATER. ,/ Municipalit3 of Anchorage Development Services Department Building Safety Division On-Site Water and Wastewater Program 4700 Bragaw Street P.O. Box 196650 Anchorage, AK 99519-6650 www.muni.org/onsite (907) 343-7904 ON-SITE SEPTIC/VVELL PERMIT APPLICATION FOR A SINGLE FAMILY DWELLING Parcel I.D. O .~-'~- ~OJ -15' Properly owner(s). ,,. ~ '/~//'t ~ / ~--"~-- ~- - _ _ , Mailing addres~ [~00.~._ ~O~_ ~~ Legal description (Sub d, Block & Lo~ / ~C. ~.r-- Legal description (To~shi~, Section & Range) Lot Size ~. ~ Sq. Ft. Number of Bedrooms THIS APPLICATION IS FOR (~:]all that apply): Absorption Field ~ Septic Tank Holding Tank r~ Privy Private Well E~] Water Storage THIS APPLICATION IS AN: Initial ~ Upgrade Renewal [] I certify that the above information is correct. I fudher cedify that this application is being made for a Single Family Dwelling and is in accordance with applicable Municipal Codes. (Signature of property owner or authorized agent) Permit/Rush Fees: Date of Payment: Receipt Number: (Rev. 11/05) Waiver Fees: Date of Payment: Receipt Number: INEEI?ING NorthRim Engineering 17237 I~ec~r Pow Cbcle Eagle RiveL AK 99577 907-694-7028 May 23, 2006 MOA On-Site Water & Wastewater Program 4700 Bragaw St Anchorage, AK 99519 RE: Tablelands, Block 4, Lot 7 A lot is being developed. The soil test was good. Groundwater was monitored during the high water month of May and is not present. A conservative design has been completed, similar to Block 4, Lot I I. The neighboring lots are mostly developed. This site should not negatively impact any of the other area lots. The lot slope is relatively flat and drops off in the rear of the lot. Please review the wastewater system design for the single family home. I have included design plans & specs, design guidelines, & soil tests. If there is need for additional information or clarification please give me a call. Design Enclosures IN RTF IM Tablelands S/D, Lot 7, Block 4 SPECIFICATIONS & DESIGN GUIDELINES Wastewater System Sizing: This is a new 4-bedroom, single family home. Most of the neighboring lots are developed. Groundwater was monitored during the high time of the year and was not present. A conventional septic system is designed similar to the design on lot I I, Block 4. This lot is over 1 acre in size and no adverse impacts are expected from development. The neighboring lots are similar. The lots are served by a public water system. No conflicts to the other lots will take place by this septic system construction. The easements are located on the drawing and are not encroached upon. Soil tests revealed sandy soil with Iow silt. An application rate of I GPD/FT: with 0.5 reduction factor for utilizing a 5' wide trench. Trench Length = 600 FT:/5'x .5 reduction factor = 60'; I line ~ 60'. No bedrock was encountered. Specification Requirements: All components and work must comply with the Municipality of Anchorage Specifications (AMC) & State of Alaska Drinking Water Regulations and Wastewater Regulations. · Two compartment, 1250 gallon septic tank. Watertight couplings on inlet & outlet. · 5' minimum between the tank and bed. 10' to property lines. · 3' of cover or insulation is required for trench; an equivalent of 1" insulation for each foot soil cover. · Tank & solid pipe must be set on well compacted, stable soil. · 4 inch diameter cleanouts with airtight caps are required 1' to 4' from foundation wall, prior to any 90 degree bend in 4 inch line, in each tank compartment, and two adjacent opposing cleanouts between the tank and the absorption field, not more than 10' from the tank positioned to provide cleanout access towards the tank and towards the absorption field. · All cleanouts must extend to at least ground level. · In solid pipe runs, ASTM D-3034 may be used in lieu ofcast iron. · Trench to be placed level, minimum of 4' to groundwater, 6' to bedrock from drain-rock. · Drain rock to be ½ inch to 2 ½ inch screened. Drain rock to be distributed uniformly throughout the trench. · Perforated pipe to be installed level with perforations down. · Silt barrier (filter fabric) to be installed above the drain rock. · Smeared trench sides must be raked or scarified before drain rock placement. · Backfill over drain rock must not be less than 36". · The finish grade must be mounded to promote drainage over the trench. · Insulation must be placed over any pipe installed under driveways or parking areas. · Approved pipe materials include cast iron, PVC ASTM D3034, PVC ASTM F789, ABS ASTM D2661, Sewer Service Line is minimum 2% slope. If the slope exceeds 25% within 50' of trenches, regrade to maintain it is less than 25%. Septic Tank to be pumped every two years or when required. Insulation board to be extruded direct burial polystyrene (Dow Styrofoam HI or equal) ~,bb Z W W W ~o. c U C C U O. C ~J Lq 0 C ID) 0 CL CL 'q' 0 U C 0 0 [2. 0 I-- (/~ I-.. C~ oC~ U ~ o ~ 0 CL 0 L £ (.J 0 0 c' r~ U 121 ~ ~0u ~oC~ U C O~ --~ ~Co; Ld 0 o 0 I, 0 ~ C c> 0 I~NEERING ', SBILS LDO - PERCDLATIDN TEST Da're PerForMed: 3/8/06 Per?orMed For: Spinett HoMes Legal Descrip'tion: Lo'~ 7, Block 4 5- 6- 7- B- 9- 10- 11 - 13 - 14 - 15- 17 - lB - 20- 21 - DEPTH (FEET) : ~. :....' Drganic SP w/Gr6vet Slope < 20X Groundwater? No Dep%h Wa~er Dep%h AFter Honl~orlng. None D6~e, 5/15/06 D~te Gross Time Net Time Depth Net Drop 3/8 0 -- 5, __ 3/8 24 24 min. 11' 6' 3/8 30 -- 4- __ 3/8 54 24 min. 10' 6' 3/8 60 -- 4. __ 3/8 84 24 min. 10' 6' Percot~¢lon R6¢e 4 min./Inch Pert Hole Di~meFer G' Tes¢ Run BeFween 3' and 4' PerFormed ByNo~hRim Fng. I PerForMed In Accordance with BN THIS DATE. DATE, 5/P4/06 CERTIFY THAT THIS TEST WAS ~'ta'te/Hunlcipcl[ Guidelines in EF?ec't N OR THRIM 907--694-- 7028 THE TABLELANDS S/D GEBTECHNICAL T,H, 1 i LDT 7 i BLDCK 4 5/24/06 1~¢ 2 TH IM I~NEERING SOILS LOG - PERCOLATION TEST Da.te Per?armed: 3/8/06 PerPorMed For~ Spinet[ Homes Le§at ])escrip.tion: Lo.t 7, Block 4 8- 3- 4 - 5- 6- 7- 8- 9- 10 - 11 - 12- 13- 14 - 15 - 16- 17 - 18- 19 - 20 - 81 - DEPTH (FEET) ,.,.: ~.: .'..';' ~..:: ?.'.','... :"i :'.':. :':. :.? '? Organlc SP Sand w/Graver S~ope < 80% Groundwater? No Depth Water Depth APter Monitoring. Date, # Dote Gross Time Ne~ TIMe Depth Ne~ Drop 1 3/8 0 -- 6' -- 2 3/8 24 24 Mtn. 12' 6' 3 3/8 30 -- 5' -- 4 3/8 54 24 Min. 11' G' 5 3/8 60 -- 5' -- 6 3/8 84 24 min. 11' 6' Percolation Rate 4 MIn,/Inch Perc Hate Diameter 6' Test Run Between 3' and 4' Comments~ Pre-.~onkPo; Per?ormed By ~:_~g, PerPormed In Accordance ON THIS DATE, DATE, 5/P4/06 N OR THRIM ENGINEERING 172J7 Beor Pow Circle ~clgle Rt~r. Alosko 99~7~' 907--694-- 7026 I ~ CERTIFY THAT THIS TEST WAS wi'th Att S-I:a'te/Municipa[ GuideUnes in EF?ec.t LOT 7 BLDCK 4 THE TABLELANDS S/D 5/24/06 .... ¢' 2 GEBTECHNICAL T.H, 8 CERTIFICATE FOR A Municipality of Anchorage Development Services Department Building Safety Division On-Site Water & Wastewater Program 4700 Braoaw Street P.O. Box 196650 , Anchorage, AK 99519-6650 www.muni.org/onsite (907) 343-7904 OF ON-SITE SYSTEHS APPROVAL SINGLE FAMILY DWELLING Parcel I.D. 051-801-15 COSA# O-~' ~ 1. GENERAL INFORMATION Expiration Date:__ Complete legal description Location (site address) Current Property owner(s) Mailing address Lending agency Mailing address Real Estate Agent Mailing address THE TABLELANDS S/D; 22974 WHISPERING BIRCH BLOCK 4,' LOT 7 MICHAEL & CHRISTINA WALLJASPER 22974 WHISPERING BIRCH DRIVE * DRIVE * CHUGIAK, AK * 99567 Day phone 210-826-4015 CHUGIAK, AK * 99567 Day phone SALLY CARMAN W/ CENTURY 21' Day phone 227-0506 400 W. TUDOR ROAD, #A-440 * ANCHORAGE~ AK * 99505 Unless otherwise requested, COSA will be held by DSD for pickup. NUMBER OFBEDROOMS: 4 '3. TYPE OF WATER SUPPLY: TYPE OF WASTEWATER DISPOSAL: Individual Well [] Individual On-site · Individual Water Storage [] Individual Holding tank [] Community Class__Well [] Community On-site [] Public Water System · Public Sewer [] The Municipality of Anchorage Development Services Department (DSD) Issues Certificates of On-Site Systems Approval (COSA) based only upon the representations given in paragraph 4 by an independent professional civil engineer registered in the State of Alaska. Certificates of On-Site Systems Approval are required for the transfer of title (except between spouses) for properties served by a single-family on-site wastewater disposal and/or water supply system. DSD also issues COSAs upon request to homeowners. Certificates of On-Site Systems Approval are valid for 90 days from the date of issue for properties served by a private or Class C well and may be reissued with new water samples. (Certificates may be reissued for a period of up to one year with valid water samples.) Certificates are valid for one year for properties served by Class A or B wells or a public water system. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. 4, STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed herefo and as of the validation date shown below, I vet~fy that ,'ny investigation, based on procedUres outlined in the Certificate of Qn-Site Systems Approval Guidelines for this application, shows that the on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation. Name of Firm GARNESS ENGINEERING GROUP, Ltd. Phone 557-6179 Address 5701 E. TUDOR ROAD, SUITE 101 * ANCHORAGE, AK 99507 Engineer's Printed Name JEFFREY A. GARNESS, P.E. Date Engineer's Comments: In conducting this evaluation, GEG,'LtD. attempted to provide a thorough, conscientious engineering analysis of the system in accordance with ADEC and MOA DSD Guidelines & Regulations. The reported results described the performance of the system under the conditions encountered at the time of the test, and separation distances measured to readily identifiable features. The operational life of all wells and septic systems depend on the local soils condition, groundwater levels that may fluctuate during the year, and the water usage of the family being served by the system. These conditions are outside the control of the evaluator of the system. Satisfactory test results do not guarantee future performance of the system, nor do they guarantee that there are no hidden defects or encroachments. GEG, LTD. can therefore not provide any warranty or future estimate of how long the system will continue to meet the operational requirements of the ADEC or MOA DSD. The content of this report is for the sole benefit of the owner listed above. Any reliance upon or use of this report by any other person or party is not authorized, nor will it confer any legal right whatsoever. DSD SIGNATURE Approved for Disapproved. bedrooms. Conditional approval for bedrooms, with the following stipulations: Attachments: COSA Checklist Septic System Advi.sory Well Flow Advisory Nitrate Advisory Arsenic Advisory Maintenance Agreements Supplemental Engineer's Report Other Original Certificate Date: .~_- /'Y) '-'! / Municipality of' Anchorage Development Services Department Building Safety Division On-Site Water & Wastewater Program 4700 Bragaw Street' P.O. Box 196650 Anchorage, 'AK 99519-6650 www.muni.org/onsite (907) 343-7904 CERTIFICATE OF 0N-SITE SYSTEMS APPROVAL CHECKLIST Legal Description: THE TABLELANDS S/D; BLOCK 4, LOT 7 Parcel ID: 051-801-15 A. WELL DATA Well type Date completed Total depth P U B LI C 'WATER If A, B, or C provide PWSID# Well Log (Y/N) Sanitary seal (Y/N). Wires properly protected (Y/N~.,.-/ ft. Cased to _ft. Casing he__round) in. Date of test FROM WELL LOG ~CTION Static water level ft. ff. Well production ,.--/g.p.m. g.p.m. WATER SAMPL~ Rfi~~'~'~ Coliform ,--"'- colonies/100 mi. Nitrate ~ mg./L. Other bacteria __ colonies/100 mi. A,,s~ic: ~ ug./L. Date of sample: Collected by: Date installed 6/25-28/2006 2 Cleanouts (Y/N) YES Depression over tank (Y/N) NO Pumper. High water alarm (Y/N) N/A JR'S PUMPING B. SEPTIC/HOLDING TANK DATA Tank Type/Material SEPTIC/STEEL Tank size 12,~0 gal Number of Compartments Foundation cleanout (Y/N) 'YES Date of pumping 11/6/2011 C. ABSORPTION FIELD DATA [*BELOW EXISTIhG CP, ADEI ' 6/2.5-.28/0,6 1.0 TRENCH Date installed 2/3/2011 Soil rating ~or ft2/bdrm)0.45 System type TRENCH 61 5 ' 4 Length 68 ft. Width 5 ft. Gravel below pipe 4.15 ft. · 12.4 610 YES NO Total depth *9.54+ ft. Eft. absorption area 680 fi2 Monitoring tube YES Depression over field NO · '1/7/2011 PASS 2 Date of adequacy test NEW Results (Pass/Fail) PASS For 2 bedrooms 40 650 48 Fluid depth in absorption field before test - in. Water added - gal. New depth - in. 1085 45 **'515 Elapsed Time: - min. Final fluid depth - in. Absorption rate >= 500+ g.p.d. Any rejuvenation treatment (past 12 mo.) (YIN & type) NONE KNOWN If yes, give date **TRENCH WAS PRESOAKED WITH 2600 GALLONS PRIOR TO TEST (1/6/2011) ***EXISTING TRENCH ONLY PASSED AS 2 BEDROOM. D. LIFT STATION Date installed "Pump on" level at Size in gallons Manhole/Access ~ J in. "Pump off" leveJ_~, High water alarm level at ,in. Datum ~ Cycles tested E. SEPARATION DISTANCES SEPARATION DISTANCES FROM WELL ON LOT TO: Meets alarm & circuit requirements? PUBLIC WATER Septic tank/lift station on lot On adjacent lots Absorption field on lot, On adjacent lots ..-..----~"- Public sewer main ~eanout Animal~ntainment areas Manure/animal excrete storage areas SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK ON LOT TO: Building foundation *5'+ ProPerty line 5'+ Water main 10'+ Water service line. 10'+ Wells on adjacent lots 200'+ SEPARATION DISTANCE FROM ABSORPTION FIELD ON LOT TO: 10'+ 10'+ Property line 10'+ Building foundation 10'+ 10'+ 100'+ Water service line 10'+ Surface water 100'+ NONE KNOWN 200'+ Curtain drain NONE KNOWN Wells on adjacent lots. 200'+ Absorption field Surface water. 2006 TRENCH 2011 TRENCH 10'+ Water main 10'+ **5' 100'+ Driveway, parking/vehicle storage 10'+ 10'+ COMMENTS *PER ORIGINAL 12/13/06 INSPECTION REPORT. **PER G. ENGINEER'S CERTIFICATION ! certify that I have determined through field inspections and review of Municipal records that the above systems are in conformance with MOA COSA guidelines in effect on this date. Engineer's Printed I~lame JEFFREY A. GARNESS Date Z,/~ / Ill 12/13/06 C.O.S.A. 0I: · . CE COSA Fee ~; Date of Payment Receipt Number (Rev. 11/05) Waiver Fee $ Date of Payment Receipt Number Z Municipality of Anchorage, Development Services Department Building Safety Division On-Site Water & Wastewater Program ~QQ B[ag.aw~S.t~e.e~ P.O. Box 196650 Anchorage, AK 99519-6650 www.muni.org/onsite (907) 343-7904 CERTIFICATE OF ON-SITE SYSTEHS APPROVAL FOR A SINGLE FAMILY DWELLING Parcel I.D. 051-801-15 1. GENERAL INFORMATION Expiration Date: ~r-~.~ /,_.. // Complete legal description Location (site address) Current Property owner(s) Mailing address Lending agency Mailing address Real Estate Agent Mailing address THE TABLELANDS S/D; BLOCK 4, LOT 7 22974 WHISPERING BIRCH DRIVE * CHUGIAK, AK * 99567 MICHAEL & CHRISTINA WALLJASPER Day phone 210-826-4015 22974 WHISPERING BIRCH DRIVE * CHUGIAK, AK * 99567 Day phone SALLY CARMAN W/ CENTURY 21 Day phone 227-0506 400 W. TUDOR ROAD, #A-440 * ANCHORAGE, AK * 99503 Unless otherwise requested, COSA will be held by DSD for pickup. NUMBER OF BEDROOMS: 4 TYPE OF WATER SUPPLY: Individual Well [] Individual Water Storage [] Community Class Well [] Public Water System [] TYPE OF WASTEWATER DISPOSAL: Individual On-site [] Individual Holding tank . [] Community On-site [] Public Sewer [] The Municipality of Anchorage Development Services Department (DSD) Issues Certificates of On-Site Systems Approval (COSA) based only upon the representations given in paragraph 4 by an independent professional civil engineer registered in the State of Alaska. Certificates of On-Site Systems Approval are required for the transfer of title (except between spouses) for properties served by a single-family on-site wastewater disposal and/or water supply system. DSD also issues COSAs upon request to homeowners. Certificates of On-Site Systems Approval are valid for 90 days from the date of issue for properties served by a private or Class C well and may be reissued with new water samples. (Certificates may be reissued for a period of up to one year with valid water samples.) Certificates are valid for one year for properties served bY Class A or B wells or a public Water system. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. 4. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and a$ of the validation date shown below, I veery that my investigation, based¢~E procedures outlined in the Certificate of On-Site Systems Approval Guid¢ines for this application, ~::' · ~'~ ~:,,. shows that the on-s~te water supply and/or wastewater disposal system is'(are) safe, functional~hd adequate . for the numb'er of be~trooms and type of structure indicated herein· I further verify that based on the . information obtained from t,~e Municipality of Anchorage files and from my investigation and inspection, the on-site ware[Supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation. .~ Name of Firm GARNESS ENGINEERING GROUP, Ltd. Phone 557-6179 Address· 570.1 E. TUDOR ROAD, SUITE 101 * ANCHORAGE, AK 99507 .Engineer's Printed Name JEFFREY A. GARNESS, P.E. Date Engineer's Comments: In conducting this evaluation, GEG, LtD. attempted to provide a thorough, conscientious engineering analysis of the system in accordance with ADEC and MQA DSD Guidelines & Regulations. The reported results described the performance of the system under the conditions encountered at the time of the test, and separation distances measured to readily identifiable features. The operational life of all wells and septic systems depend on the local soils condition, groundwater levels that may fluctuate during the year, and the water usage of the family being served by the system. These conditions are outside the control of the evaluator of the system. Satisfactory test results do not guarantee future performance of the system, nor do they guarantee that there are no hidden defects or encroachments. GEG, LTD. can therefore not provide any warranty or future estimate of how long the system will continue to meet the · operational requirements of the ADEC or MOA DSD. The content of this report is for the sole benefit of the owner listed above. Any reliance upon or use of this report by any other person or party is not authorized, nor will it confer any legal right whatsoever. 5. DSD SIGNATURE Approved for bedrooms. Disapproved. Conditional approval for ~ bedrooms, with the following stipulations: Attachments: COSA Checklist Septic System Advisory Well Flow Advisory Arsenic Advisory Maintenance Agreements Supplemental Engineer's Repo~ Other Original Certificate Date: c,2 - / - / / Municipality of Anchorage Development Services Department Building Safety Division On-Site Water & Wastewater Program 4700 Bragaw Street P.O. Box 196650 Anchorage, AK 99519-6650 www. muni.org/onsite (907) 343-7904 CERTIFICATE OF ON-SITE SYSTEMS APPROVAL CHECKLIST Legal Description: THE TABLELANDS S/D; BLOCK 4, LOT 7 Parcel ID: 0._~"'/--.{~ 0 1-/0-" A. WELLDATA PUBL C WATER Well type If A, B, or C provide PWSID# Well Log (Y/N) Date completed Sanitary seal (Y/N) Wires properly protected (Y/N~~ Total depth ft. Cased to ft. Casing he__round) in. FROM WELL LOG AT I/I,I,I~CTION Dateoftest ' .. ~ ~ : __~ , Static water level ~_ff./---'~ ' ~__ ft. Well production _ g.p.m. ~~ g.p.m.~ :o~Tf:: SA MP~ Nitrate m g./L. Other bacteria colonies/100 mi. Am~nic: ug./L. Date of sample: Collected by: B. SEPTIC/HOLDING TANK DATA Tank Type/Material SEPTIC/STEEL Date installed 6/23-28/2006 Tanksize 1250 gal. Number of Compartments 2 Foundation cleanout (Y/N) YES Depression over tank (Y/N) NO Date of pumping 1/6/2011 Pumper Cleanouts (Y/N) High water alarm (Y/N) JR'S PUMPING YES N/A ABSORPTION FIELD DATA ~*BELOW EXISTING (;RADEI Date installed 6/2.3-28/06 Soil rating ~or ft2/bdrm) 1.0 System type TRENCH Length 61 ' ft.. Width 5 ft. Gravel below pipe 4 ft. Total depth '12.4 ft. Eft. absorption area 610 ft2 Monitoring tube YES Depression over field NO Date of adequacy test *'1/7/2011 Results (Pass/Faij~~I~ For 4 bedrooms Fluid depth in absorption field before test 40 in. Water added 630 gal. New depth 48 in. Elapsed Time: 1085 min. Final fluid depth ,*5 in. Absorption rate >= **'315 g.p.d. Any rejuvenation treatment (past 12 mo.) (Y/N & type) NONE KNOWN If yes, give date **TRENCH WAS PRESOAKED WITH 2600 GALLONS PRIOR TO TEST (1/6/2011). ***REQUEST CONDITIONAL APPROVAL. SYSTEM TO BE UPGRADED BY 2/11/2011. D. LIFT STATION Date installed "Pump on" level at.__ Size in gallons Manhole/Access ~ ~ .in. "Pump off" levef_.a~, High water alarm level at in. ~ Cycles tested E. SEPARATION DISTANCES SEPARATION DISTANCES FROM WELL ON LOT TO: Meets alarm & circuit requirements? PUBLIC WATER Septic tank/lift station on lot On adjacent lots Absorption field on lot On adjacent lots Public sewer main ......~eanout Sewer/septic service line.~ .-------~ Holding tank ~ent areas Manure/animal excrete storage areas SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK ON LOT TO: Building foundation *5'+ Property line 5'+ Absorption field Water main 10'+ Water service line, 10'+ Surface water. **5' 100'+ Wells on adjacent lots 200'+ SEPARATION DISTANCE FROM ABSORPTION FIELD ON LOT TO: Property line 10'+ Building foundation 10'+ Water service line 10'+ Surface water 100'+ Curtain drain NONE KNOWN Wells on adjacent lots 200'+ Water main. 10'+ Driveway, parking/vehicle storage 10'+ F. COMMENTS *PER ORIGINAL 12/13/06 INSPECTION REPORT. **PER ENGINEER'S CERTIFICATION I certify that I have determined through field inspections and review of Municipal records that the above systems are in conformance with MOA COSA guidelines in effect on this date. Engineer's Printed Name JEFFREY A. GARNESS Date I I~'(~/l' COSA Fee $~'5'.~._ ' Date of Payment Receipt Number (Rev. 11/05) 12/13/06 C.O.S.A. Waiver Fee $ Date of Payment Receipt Number Municipality of Anchorage Development Services Department Building Safety Division On-Site Water and Wastewater Program 4700 Bragaw Street P.O. Box 196650 Anchorage, AK 99519-6650 www.muni.org/onsite (907) 343-7904 CERTIFICATE OF ON-SITE SYSTEMS APPROVAL FOR A SINGLE FAMILY DWELLING Parcel I.D. t. GENERAL INFORMATION Complete legal description '7"7-//~' Location (site address) ..~-P2 ~' 7q Current Property owner(s) 5,F'/AI~6,/ Mailing address /~'~'43 ~ Lending agency Day phone Mailing address Real Estate Agent Dayphone Mailing Address Unless otherwise requested, COSA w#l be held by DSD for pickup. 2. NUMBER OF BEDROOMS: . .. 3. TYPE OF WATER SUPPLY: Individual Well Individual Water Storage Community Class Public Water System Well TYPE OF WASTEWATER DISPOSAL: Individual On-site ,,~ Individual Holding Tank [] [] community On-site Public Sewer [] The Municipality of Anchorage Development Services Department (DSD) issues Certificates of On-Site Systems Approval (COSA) based only upon the representations given in paragraph 4 by an independent professional civil engineer registered In Ihe State of Alaska..Certificates of On-Site Systems Approval are required for the transfer of title (except between spouses) for properties 'served by a single-family on-site wastewater disposal and/or water supply system. DSD also issues COSAs upon request to homeowners. Certificates of On-Site Systems Approval are valid for 90 days from the date of issue for properties served by a private or Class C wall and may be reissued with new water sample results. (Certificates may be reissued for a period of up to one year with valid water samples.) Certificates are valid for one year for properties served by Class A or B wells or a public water system. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. 4. STATEMENT OF INSPECTION BY ENGINEER Address ./'7.~ Engineer's Printed Name As certified by my seal affixed hereto and as of the validation date shown below, I verify that my Investigation, based on procedures outJined in the Certificate of On-Site Systems Approval Guidelines for this application. shows Ihat the on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from my Investigation and inspection, the on-site water supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation. NameofFirm ../_.t~'/3~'~:'¢~1. p~'"~. ~---,,~'c~...p~ Phone 6"~'~-,/'-7d~'oc'' 5. DSD SIGNATURE / Approved for Disapproved. Conditional approval for bedrooms. bedrooms, with the following stipulations: Attachments: COSA Checklist Septic System Advisory Well Flow Advisory Nitrate Advisory X Arsenic Advisory Maintenance Agreements Supplemental Engineer's Report Other By:. {Rev, t 1~5) Original Certificate Date: Municipality of Anchorage Development Services Department Building Safety Division On-Site Water & Wastewater Program 4700 Sragew Street P.O. Box 196650 Anchorage. AK 99519-6650 www.munLorg/onsite (9O7) 343-79O4 CERTIFICATE OF ON-SITE SYSTEMS APPROVAL CHECKLIST Legal Description: A. WELL DATA J'~U Well type / Date eom pl~t~;Y Total depth,,/ft. Dale of test Static water level Well production Parcel WATER SAMPLE RE~LTS: Coliform __.eelool~/~? mL Arsenic: mga B. SEPTIC/HOLDING TANK DATA Tank Type/Material Tank size/.ZS'~, gal. If A, B, or C provide ~y~fSID # / Sanitary sea~J~/N) Cased to / ft. ( FROM WELL LOG g.p.m. Well Log (Y/N) Wires properly protected (~), Casing height (above gro/dnd) AT INSPECTION in. Nitrate mg/L Other bacteria ..~ colonies/100 mL Dale of sample: Collected by:. / Number of Compartments Date installed Cleanouts (Y/N) Foundalion cleanout (Y/N) Date of pumping C. ABSORPTION FIELD DATA Depression over tank (Y/N) . Pumper High waler alarm (Y/N) Dateinslalled~"/~ea.J~:~'' Soilrating (g.p.d./ft=c~lt~) / Systemlype~ Length ~"/ ft. Width ~" ft. Gravel below pipe y ft. Tolal depth I~ ft. Eft. absorption area ~a_/_.~.ft2 Monitoring tube ~ Depression over field /~ Date of adequacy test /4~'~,/ Results (Pass/Fail) For. ~7/ bedrooms Fluid deplh in absorption field before test in. Water added gal. New depth in. Elapsed Time: min. Final fluid depth in. Absorption rate >= g.p.d. Any rejuvenation treatment (past 12 mo.) (Y/N & type) If yes, give dale D. LIFT STATION ~/'~ E. SEPARATION DISTANCES Size in gallons ': Uy(:: :(:t leedVel at ~n' Manhole/Access (/~)/ SEPARATION DISTANCES FROM WELL ON LOT TO: ,,'¢~'// Septic fan.iff station on lot t On adjacent lots / On adjacent lots / Public sewer manhol~.~nout. HM:~iu~ge/t:r~km ea~xcrete storage areas / Absorption field on lot / / Public sewer main / Sewer/septic servi~ line / Animal containrj~ent areas SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK ON LOT TO: Absorption field Surface water Building foundation ,_~' ~ Water main / (~ ~'~ Wells on adjecenl lots ~ Property llne ./~ Water service line /~) ¢'~ SEPARATION DISTANCE FROM ABSORPTION FIELD ON LOT TO: in. COSA Fee $ Dale of Payment Receipt Number (Rev. 11/05) ~ (~ ~--~ Receipt Number Property line / O /4- Building foundation Water Service line ,,/~ ~'~' Surface water fO Curtain drain ~ Wells on adjacent lots .2~'(~ .~ F. COMMENTS ~ s CE.T,.C^T,O" review of Municrp co¢ y conformance with MOA COSA guidelines in effect on this date. ~ ,_~.;~'~.....,.~ En ineer's Printed Name <~"7TM ~/~'/'~') Date /V Z 0 LO