Loading...
HomeMy WebLinkAboutTRAILS END BLK 3 LT 7 Municipality of Anchorage Development Services Department Building Safety Division On-Site Water and Wastewater Program, 4700 Elmore Read P.O. Box 196650 Anchorage, AK 99507 Page of www.ci.anchorage.ak, us (907) 343-7904 ON-SITE WASTEWATER DISPOSAL SYSTEM AND/OR WELL INSPECTION REPORT Permit Number: sw060158 PID Number: 015-191-44 Name: Innovative Building Solutions Wastewater System: [] New [] Upgrade Address: 17510 Snowcrest Lane Anchorage, AK 99516 ABSORPTION FIELD Phone: 929-4922 Number of Bedrooms: 3 [] DeepTrench [] Shallow Trench [] Bed ~ Mound [] Other: Soil Rating: Total Depth from odginal grade: LEGAL DESCRIPTION 4 GPD/Ft2 1.5 Ft. Block: 3 Lot: 7A Subdivision: Depth to pipe bottom from odginal grade: Gravel depth beneath pipe: Trails End 0 Ft. .5 Ft. Township: Range: Section: Fill added above odginat grade: Gravel Length: 4-5 Ft. 20 Ft. Well: [] New [] Upgrade Grave~ width: Number of lines: Distance between lines: 10 Ft. 3 3.5 Ft, Classification (Private, A. B, C): Total Depth: Cased to: Total absorption area: Pipe Matehah Private 226 Ft. 92 Ft. 200 Ft2 ASTM D3034 PVC Ddller: Date Drilled: Static Water Level: Instelfer: Date Installed: Alpine Drilling 4/7/07 0 Ft. Alaska Excavating 7/10-11/2007 Yield: Pump Set at: Casing Height Above Ground: TAN K 20 GPM *** Ft. >1.5 Ft. SEPARATION DISTANCES [] Septic [] Holding [] S.T.E.P. [] Other: '~ To Septic Absorption Lift Holding ~ublic/Private Manufacturer: Capacity: Tank Field Station Tank Sewer Line Advantex/Anchorage Tank 1,500 Gal, Matedai: Number of Compartments: Well >100' >100' >100' N/A >25' Steel Two (2) surface water >100' >100' >100' N/A ~ / LIFT STATION Size: Gal, Manufacturer: Lot Line >5' 1' >5' N/A 500 Orenco/Anchorage Tank "Pump on" level at: "Pump off' level at: in. High water alarm at: Foundation >5' >10' >5' N/A 28 in, 28 32 in, Pump Make & Model Electhcat Inspections performed by: Curtain Drain >20' >20' >20' N/A Orenco Model 20 Municipality of Anchorage Remarks: See Lot Line Waiver. BENCH MARK Location and Description: Landscaping Over Mount to be Completed by 6/15/09. Garage Slab Assumed Elevation: .... Well is Artesian. No Pump Required. 100.00 Ft. Inspections performed by: MEA Dates: 1st 7/10/07 2nd 7/11/07 Development Services Department Approval C.~°nditi°nalAppr°va'.>>/~- *v'~''/..~, / _ /~' ,ff__~' Date: /.L~-,~,~-~¢, Reviewed and approved by: ?,~/¢/..~ ~ Z{..,' /~,~ Date:/./- / ~ / ~ o~oo,oo-~ ~o.oo, / ,, ,~ ~1. I / ~ ~ I~1 / I ~l~ I ~ I ~ /, -J ~ I / / - ~ ~ ~1. / I ~ ~ / N O0'O0'O0"E 120.00' / / ~"'i~ '~ BROWDER AVENUE ' ? ......... Municipality of Anchorage DEVEOPMENT SERVICES DEPARTMENT 4700 Elmora Road Anchorage, AK. 99519-6655 - 343-7904 On-Site Wastewater Disposal System or Well Inspection Report Permit No.: SW060158 Page 3 of 3 PID No, 015-191-44 97.2 Existing Grade 90.5 Groundwater at 955' 1050 PROFILE AS-BUILT Scale: NONE SGS Ref.# 1091438001 Client Name Anderson En$inccring Printed Date/rime 04/20/2009 9:$8 ?roject Name~# Lot 7, Block 3, Trails End Collected Date/Time 04/13/2009 14:20 Client Sample ID Lot 7, Block 3, Trails End Received Dale/'rlme 04/13/2009 15:40 Ms~x Drinking Watcr Technical Director Stephen C. £de PWSID 0 Samvl¢ Remar 'l'~: Allowable Prep Analysis Paramet~' Result~ PQL Units Method Conlatner ID Limits Date Date Init Metals b~' ICP/MS Arsenic ND 5.00 ug/L EP200.8 C (<101 04/14/09 04/16/09 NRB Waters De~&r~aent Total Nitrate/Nitrite-lq 2.28 0.100 mg/L S.~L?.0 4500NO3-F B (<10) 04/17/09 J-DZ Microbiology Laboratory Colony Count 0 Total Coliform 0 Fecal Coliform 0 col/100mL SM20 9222B A ¢<200) col/100mL SM20 9222B A (<1) col/100mL SM20 9222B A (<11 04113/09 DLC 04113/09 DLC 04/13/09 DLC 20f4 N O0'O0'O0'E 120.00' 5' UTIL. ESMT. 30.5' 28.9' 14.0' N O0'O0'O0'E 120.00' BROWDER AVENUE 0 Z Inspection Report Municipality of Anchorage, Building Safety Division 4700 Elmore Road INFO & HELP (907) 343-8211 INSPECTION: VOICE (907) 343-8300' FAX (907)249-7777' www.muni.org Name Bill Company Brickwell, Inc. Address 11300 BROWDER AVE Grid SW2641 Subdivision TRAILS END Work Description Permit # 07-0635 Inspection Date 15-Apr-2009 AM Phone 440-9351 LOT 7 BK3 TR n/a 2491 sq ft living / 985 sq ft garage Permit Technician MORIsA, MARIAMENE G. Comments or Directions Please Call- Thanks Inspection Type Electrical:Final Elect'rical Comments (for inspector use qnly) ALPINE DRILLING & ENTERPRISES Permit Number: #SW060158, Date oflssuc: Date Started: 4-6-07 Dale Completed: 4-7.07, Legal Description: Property Owner Name & Address: Borehole Data: Soll Type, T~.ickness & Water Strata stick-up 0 3 organics 3 9 silt 9 25 silty gravel 25 42 gravelly silt 81 84 bedrock 84 226 H20 202 226 Parcel Identification Number:. 015-191-44 Is x~cll located at approved permit location? [] Yes [--] No Trails Ends B#c 3 Lot 7 Innovative Building Solutions PO Box 230666 Anchorage, Alaska 99523 Depth (ft) Method of Drilling [] air rotary From To [] cable tool Casing type: stee! Wall Thickness: .250 inches Diameter:. _6 inches Depth: 92 feet Liner T)'pe: __ Diameter: ~ inches Depth: Casing stickup above ground: _3 feet feet Static water level (f~om ground level): Ofcct Pu~ping level: 226,feet after _2 hours pttmping 20 gpm Recovery Rate: 20 gpm Method of Testing: air lift ~,Vell Intake Opening Type: [] Open End [] Open Hole [] Screened Start feet Stopped feet [] Perforations Start feet Stopped ~ feet Grout Type: bentonite gramdes Volume:/_ Depth: Start 0 feet Stopped_? feet Pump: Intake Depth feet Pum~ ~z=. - hp Br~d Name Well Disinfected Upon Completion? [] Yes [] No Method of Disinfection: .chlorine tablets · Comments: Well Driller: Alpine Drilling & Enterprises PO Box 110496 Anchorage Alaska 99511 Attention: The well driller shall provide a well log to the property owner within 30 days of completion and the prope~ owner or the well drillcr shall provide a well !o§ to tile Development Services Dcp~u~ent within 60 days cf'completion. 15:16 F,4~ 907 343 7997 .,, ON SITE May 30, 2007 Mike Anderson, p.£. Ande~on En~neefing P.O. Box 240773 A~chorage, Ahska 99524 Subject: 'Pi'ails End S/D Block 3 Lot 7 On-Site Water & Waslewater Permit (SW060158) Dear Mr. Anderson, This letter will servc as notice the On-Site Water & Wastcwater Permit SW060185 been rcinstated for Trails End S/D Block 3 Lot 7. The memorandum dated May 4'~ by Anderson Enginccdng provided information that an upgrade site for a n~w septic system on Trails End $/D Block 3 LOt 4 can be found. Anchorage Municipal Code requires thc wcll on subject lot to any original and replacement Set,tlc Absorption System m~fntain a 100 foot rain/mum scparation. This does not appear to exist on your property. Reinstating this po'mit is based on thc information Anderson Engineering provided addressing all of the above issues. If you have questions on the above plcasc contact mc at 341-7904. Sincerely, On'-Site Water & Wast~,at~r Program Community, Security, Pros_verity of Anchorage · Telephone (907) ~L~-&'~)I * I:~x (907) ~TO0 Bragw. v S~rcct * Anchorngc, Alaska 99507 Ma!/or Mark Beglch ~:m..Lo~ Building S~ety Dhqslon May 1,2007 Mike Anderson, P.E. AndersonEngineering P.O. Box 240773 Anchorage, Alaska 99524 Subject: Trails End S/D Block 3 Lot 7 On-Site Water & Wastewater Permit (SW060158) Dear Mr. Anderson, At this time the On-Site Water & Wastewater Permit SW060185 has been revoked. This letter will serve as notice that there is no valid permit to construct a water-well and septic system. · Anchorage Municipal Code requires the well on subject lot to any original and replacement Septic Absorption System maintain a 100 foot minimum separation. ............ This does not appear to exist on your property. - .... Reinstating the permit will require documentation of Trails End S/D Block 3 Lot 7 well location addressing all ofthe above issues. If you have questions on the above please contact me at 343-7907. Daniel J. Roth Program Manager On-Site Water & Wastewater Program Comntunil.y, Security, Prosperity ANDERSON ENGINEERING P.O. BOX 240773 ANCHORAGE, AK 99524 522-7773 677-7766 (FAX) MEMORANDUM DATE: May 4, 2007 TO: Joe Goodall FROM: Mike Anderson, P.E. SUBJECT: Lot 7, Block 3, Trails End Subdivision Septic System Permit No. SW060158 The attached drawing shows the location of the well as constructed on Lot 7, Block 3, Trails End Subdivision. The septic system on Lot 4 is totally outside the 100' protective radius. The upgrade site for the system would be an Advantex or similar type system. The percolation test completed on the lot indicates a 12 minute per inch rate. The three bedroom home on the lot would then require a 90 square foot absorption area based on an application rate of 5 gallons per day per square foot. This area is shown within the 30' radius of the test hole placed in 1998 and more than 10' from the existing bed. It appears based on all available information that an upgrade site for a new septic system for Lot 4 can be found. Please review the attached data and let me know if you have further questions. r- N O0'O0'~Q'[ 120,00' BROWDER AVENUE Z Z MUNICIPALITY OF ANCHORAGE Development Services Department On-Site Water & Wastewater Program 4700 South Bragaw Street P.O. Box 196650, Anchorage, AK 99519-6650 (907) 343-7904 ON-SITE WASTEWATER DISPOSAL SYSTEM I WATER SUPPLY PERMIT Initial Date Issued: Jun 15, 2006 Expiration Date: Jun 15, 2007 Permit Number: SW060158 Parcel ID: 016-191-44 Legal Description: TRAILS ENDS SUBDIVISION BLOCK 3 LOT 7 Design Engineer: 0014 ANDERSON ENGINEERING Site Address: 11300 BROWDER AVENUE Ov~3er Name: INNOVATIVE BUILDING SOLUTIONS Lot Size: 22800 SQ. FT. Owner Address: 17510 SNOWCREST LANE Total Bedrooms: 3 Permit Bedrooms: 3 ANCHORAGE, AK 99516- This permit is for the construction of: [] Disposal Field [] Septic Tank [] Holding Tank [] Privy [] Private Well [] Water Storage All construction must be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal Code Chapters 15.55 and 15.65 and the State of Alaska Wa stewater Disposal Regulations ( 18AAC72 ) and Drinking Water Regulations ( 18AAC80 ). 3. The engineer must notify DSD at least 2 hours prior to each inspection. Provide notification by calling (907) 343-7904 ( 24 hours ). ( Not required for a Water Supply Permit only ). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must be either: A. Open and closed on the same day. B. Covered, sealed, and heated to prevent freezing. 5. The following special provisions. -THE UPPER SIX INCHES OF THE MOUND SYSTEM MUST CONSIST OF TOP SOIL AND THE MOUND MUST BE VEGETATED SUFFICIENTLY TO PREVENT EROSION. Received By: Issued By:. Date: Date: Municipality of Anchorage Development Services Department Building Safety Division On-Site Water and Wastewater Program 4700 South Bragaw St. P.O. Box 196650 Anchorage, AK 99519-6650 www. ci.anchorage.ak.us (907) 343-7904 ON-SITE SEWER/VVELL PERMIT APPLICATION FOR A SINGLE FAMILY DWELLING Parcel I.D. _ Permit Number SW Property owner(s)..Innovative Bu1'ldin!~ Solutions" Mailing address (1)17510 Snowcrest L~ne Anchorage, AK 99516 Mailing address (2)11300 Browder Avenue Zip Code Legal description (Lot, Block & Sub'd.) Lot 7. Block 3, Trails End Subdivision Legal description (Section, Township & Range) . Lot Size 22,800 SF Acres/Sq. Ft. Number of Bedrooms .Three (3) Day phone _929-4922 [] Well Only [] [] Water Storage [] THIS APPLICATION IS FOR: Sewer Only Sewer and Well Sewer Upgrade THIS PROPERTY CONTAINS: Hot Tub Swimming Pool Therapy Pool [] Jacuzzi [] [] Water Softening Unit [] I certify that the above information is correct. I further certify that this application is being made for a Single Family Dwelling and is in accordance with applicable Municipal Codes. (Signature of property owner or authorized agent) Permit Fees: Date of Payment:_ I~!?/o~' Receipt Number:.. '-7~--'~ I~ (Rev, 12/00) Waiver Fees:.~ 17 ~" Date of Payment: /~ Receipt Number. ANDERSON ENGINEERING P.O. BOX 240773 ANCHORAGE, AK 99524 522-7773 677-7766 (FAX} October 7, 2005 Municipality of Anchorage Development Services Department On-Site Water and Wastewater Program 4700 South Bragaw Street Anchorage, AK 99519-6650 Subject: Lot 7, Block 3, Trails End Subdivision Septic System Design and Permit Application Impacts to Adjacent Properties Dear Onsite Services Engineer: The owner of Lot 7 Block 3, Trails End Subdivision intends to construct a three bedroom home on the lot. We are therefore requesting a permit be issued for a well and septic system to serve the new home. The soil conditions, groundwater elevation and house location make the construction of a conventional septic system nearly impossible. We have therefore decided to place an Advantex Treatment System on the lot to provide the most effective treatment of the septic effluent prior to discharge into the surrounding soil strata. The location of the absorption bed is shown on the attached Site Plan. Additional documentation is furnished which identifies the wells and septic systems on adjacent lots. The test holes placed on this lot revealed silty sand and gravel. The percolation rate in the materials encountered was 1 to 5 minutes per inch. Groundwater was found during the excavation from 3' to 6' below the surface. A sub drain was placed this summer to lower the groundwater level. Recent water monitoring indicates the groundwater levels have fallen below the bottom of the monitor tubes. We are therefore proposing to place a three-bedroom Advantex Treatment System. The absorption bed will each be 20' long x 10' wide. The distribution line in the trench will be placed at the existing ground level. Coarse sand will be required to replace the existing organic material and fill on the lot. 3' of fill will be placed above the trenches and 4' over the septic tank to meet Municipal Code and prevent freezing. The ground surface of the lot is basically fiat with only minor grades sloping to the west. The absorption bed will be constructed parallel with the slope as much as possible in conformance with Municipal requirements. All components of the new septic system will be constructed a minimum of 100' from any surface water and 10' from the water service proposed for this lot. 'Lo~ 7, Block 3, Trails End October 7, 2005 Page Two If the system is constructed in accordance with our design the following statements apply: The system, if constructed as designed, will have no adverse impact on the wells in the area or those to be constructed in the future. 2. The system, if constructed as designed, will have no adverse impact on existing septic systems in the area or those to be constructed in the future. 3. The system, if constructed as designed, will have no adverse impact on reserve space, either surface or subsurface, on any lots located in the area. 4. The system, if constructed as designed, will have no adverse impact on drainage patterns in the area. The current drainage pattern will be maintained. Sincerely, Michael E. Anderson, P.E. Attachments ANDERSON ENGINEERING P.O. BOX 240773 ANCHORAGE, AK 99524 522-7773 677-7766 (FAX) October 7, 2005 Municipality of Anchorage Development Services Department On-Site Water and Wastewater Program P.O. Box 196650 Anchorage, AK 99519-6650 Subject: Lot 7, Block 3, Trails End Subdivision Separation Distance Waiver Absorption Trench to Lot Line Dear On Site Services Engineer: The wells located on this and adjacent lots reduce the surface area for construction of a septic system on this lot. We have located an area in the northeast corner which is acceptable for an Advantex Treatment System. The absorption bed will be constructed within 1' of the north lot line. Placement of the absorption bed at this location will have no adverse affect on wells or septic systems in the area. The use of the Advantex is also less harmful to the environment than a standard system. We therefore request a waiver be issued allowing the bed to be 1' from the north property line. Sincerely, Michael E. Anderson, P.E. ANDERSON ENGINEERING P.O. BOX 240773 ANCHORAGE, AK 99524 522-7773 677-7766 {FAX) MEMO DATE: 12/1912005 TO: Joe Goodall WITH: MoA/On-Site Water and Wastewater FROM: Mike Anderson SUBJECT: Lot 7, Block 3, Trails End Subdivision Septic System Construction Permit Attached is a drawing showing the location of all wells and septic systems in the area of Lot 7, Block 3, Trails End Subdivision. There are no conflicts between the proposed well and septic system on Lot 7, Block 3 and those located on adjacent lots. We have also included a note on the Site Plan concerning surface water. Some grading and ditching will be required to insure the 100' separation distance is met. The homeowner maintenance agreement has been completed. Please let me know if you have further questions. Shebonof Avenue 189.06 10 2 VAt. O' VACANT 3 4 V~A~' 5 190.00 Troil Street NOTE: AREA MAP SCALE 1' = 100' Shebanof Avenue Trail ..- ~..-.:...' _C......~-Oo. Street NOTE: AREA MAP ~;CALE I' = 100' 7 0 N~ mo :~ 0 ,,- mo (DC) ]nN3^V W3aMOWB __ u.mo.~O qnS .Il b u!oJO qnS ~ 3.00,00.00 N 0 ' I I I I b '.1.~53 '911~ .S ~ .00'0: & ~.00.00~0 N o~ Z I,I I mo DO,,' m8 I (DC) __ u:oJ0 qn$ ,1 .oo'o~6j ]tnNqAV ~I]OMOSB u!oJa qnS '4.00,00.00 N P o -o~E:= .11 'J.I~S3 "llJ. f] .g ,00'0~ I, 3.00,00.00 N Z LOT 7, BLOCK 3, TRAILS END SUBDIVISION DESIGN FACTORS: SYSTEM REQUIREMENTS: 3 Bedroom Home Raised Bed System Perc. Rate: 1-5 Min./inch 4 Bedroom Advantex Treatment System Application Rate: 4 GPD/SF 500 Gallon Add On Lift Station Raised Bed Absorption System 3 Bedrooms X 150 GPD/4 GPD/SF = 112.5 SF Absorption Area 112.5 SFI10 SF (~dth) = 11.5 LF Bed Length THEREFORE: Construct an Oversized Raised Bed 20' Long x 10' V~de as Shown Below, Place Distribution Piping at Odginal Ground Surface, Remove Organics and Fill and Place Coarse Sand to Provide 4' Separation From Groundwater. Place Insulation and 2' of Cover Over Bed or Mound Over Bed Minimum of 3', Place 4' of Fill Over Tank. Top 6" of Mound Must Be Topsoiled and Vegetated to Prevent Erosion, Natural Backfill 2' Insulation & 2' Cover (Min.) J / / / { { / 0 0 Drainfield Rock Coarse Sand (See Spedficetion) As Required for Levelling And Replacement of Fill and Organics. In Situ GM Soil 1' PVC ~ 3/16" Holes ...... ~-- 10 Each Lateral r-x~sung GmunC 1.75' 3.5' 3.5' 1.75' NOTE: TYPICAL BED SECTION (NO SCALE) Grade Area Sun'ounding Bed to Drain Away, Minimum 6' Separation From Bedrock. Minimum 4' Separation From Groundwater. Minimum 100' Separation From Wells In the Area. Minimum 100' Separation From Surface Water or Streams. Minimum 10' Separation From Water Service Line. AdvanTex* Treatment System' AX20- Mode la :~' ': 40x94Pod ' ~ YAIJ1.T SYSTEM SECTION "~' "~'"'~ NOT TO SCALE NOTE.' SYSTEM MUST BE P~CED IN STRICT CONFORMANCE WITH MANUFACTURER'S RECOMMENDATIONS. D~PTII (feet) I 2 3 4-- 5-- 6 7-- 8 9 20' MUNICIPALITY OF ANCHORAGE DEVELOPMENT SERVICES DEPARTMENT /-*700 SOUTH BRAGAW STREET ANCHORAGE, AK c)c)51c)-6650 SOILS LOG - PERCOLATION TEST LEGAL DESCRIPTION; Lot 7, Block 3, Trails End Subdivision PERFORMED FOR; Innovative Buildinc,; Solutions DATE: 5/11/2004 PROJECT No · PARCEL ID~/' TECHNICIAN: A. Harolo TESTIIOLE# I ] OG/OL SLOPE Oraganlc Fill Silty Sand With Gravel SM WAS G ROUND WATER £NCO~h'qTERED? Yes BOH IF Xl~ ~ WIIAT DEPTI{? DEPTII OF WATER AFTER MONITORING: DATE OF MONITORIN(]: SITE PLAN See Site Plan See Site Plan READ NG GROSS TIME NET T MEI DwEP ' R°F iNET DROF (MINUTES) (MINUTES)I (INCHES) [ (INCHES) TEST HOLE PRESOAKED PRIOR TO TESTING: I 11:09 11.25" O,AR~. 2 11:19 10 7.75" 3.5" 3 11:20 11" REC.AR~E 4 11:30 10 8" 3" 5 11:31 10.88" RECnARC,~ 6 11:41 10 7.75" 3.13" PERCOLATION RATE:3.2 (MIN/INCII) PERC. IIOLE DIA, 6 TEST RUN BETWEEN: ,..3 FT. and ~. FT. (INCI lES) COMMENTS: TEST HOLE PRE SOAKED PRIOR TO TEST. TEST PERFORMED BY ANDERSON ENGINEERING SOILS TECHNICIAN. I, MICI IAEL E. ANDERSON CERTIFY TI IAT Tills WAS PERFORMED IN ACCORDANCE WITI I ALL STATE AND MUNICIPLE GUIDELINES IN EFFECT ON Tills DATE:. 10/7/~005 ON-SITE WASTEWATER DISPOSAL SYSTEM CONSTRUCTION AND MATERIAL SPECIFICATIONS SUBJECT: LOT 7, BLOCK 3, TRAILS END SUBDIVISION GENERAL: The scope of this project includes the procurement and placement of a new Throe Bedroom Advantex Troatment System, which includes a septic tank sized for three bedrooms with an AX-20 Pod to serve the proposed home on the lot. An add on lift station will be requirod as gravity flow from the Advantex Filter is not possible. The new system will be placed at the location shown on the Site Plan. The new septic system also includes the construction of a new 20' long X 10' wide absorption bed at the location also shown on the Site Plan and at the configuration shown. The distribution line in the bed will be placed at the existing ground surface. Coarse sand will be roquirod to roplace the existing organics and fill material, which must be romoved to the in situ material below. Total depth of the bed may be as much as 3' below the ground surface. The new system must be placed a minimum of 10' from the water service on the lot and those currontly in place on adjacent lots and 100' from any surface water located on or near the lot. The new tronch must be covered with a minimum of 3' of cover. In lieu of cover 2" of direct bury insulation and 2' of cover is acceptable. Construction shall be in accordance with the approved site plan, design drawings, Municipal Permit with any special provisions or conditions, and all applicable State and Municipal Wastewater Disposal Regulations. The Contractor shall be responsible for obtaining all underground utility locates and for the layout of the septic system and verification of the location of all lot lines. Unless specifically agreed otherwise, the contractor shall be responsible for final grading aroas subsequently depressed from soil settling. Property owner shall be rosponsible for revegetation of affected aroas unless specifically agroed otherwise. Contractors installing wastewater disposal systems must be certified by the Municipal Department of Health and Human Services for system installations. Owners installing their own systems must receive prior approval from D.H.H.S. before beginning system installation. · · ' Lot 7, Block 3, Trails End .October 7, 2005 Page 2 of 4 SEPTIC TANK INSTALLATION The Advantex Treatment System must be installed in conformance with specifications and regulations furnished by the manufacturer, Anchorage Tank and Orenco Systems Incorporated. No variances from the manufacturer's specifications will be allowed without permission from the manufacturer and Municipal representatives. A septic tank is to be constructed by a certified septic tank manufacturer. Construction shall include two 4" cleanouts for pumping access. 3. The septic tank shall be sufficiently bedded to prevent settling or shifting of the tank. 4. All standpipes on the septic tank shall extend a minimum of 12 inches above final grade. 5. Tanks installed without 4' of cover shall have a minimum of 2" of direct burial insulation. A foundation cleanout shall be installed one to four feet from the building foundation. Two cleanouts are required between the tank and the drainfield. 7. Final grading over the tank shall be such that a positive slope exists away from the septic tank. DRAINFIELD CONSTRUCTION: 1. The drainfield shall be constructed to the dimensions shown on the design. The bottom of the bed shall be within 2" of level. Distribution piping must be placed level with perforations down atop a level bed of drainfield rock. Rock should then be placed over the pipe to provide a minimum of 2" of cover. 3. A silt barrier or geotextile fabric must be placed between the drainfield rock and the natural soil backfill. 4. Monitor tubes must be 4" in diameter and installed at the locations shown on the design. The portion below ground must be perforated. Contractor shall verify the septic tank and drainfield are a minimum 100' away from any private water wells in the area, 150' from a Class "C" Well or 200' from any community well. ' Lot 7, Block 3, Trails End .October 7, 2005 Page 3 of 4 Direct bury insulation must be placed over the distribution system if less than 3' of backfill depth is available. Finish grade over the trench must be mounded to prevent settlement or depressions. 7. Grade area surrounding the absorption trenches to drain away. A minimum 2' of accepting soil is required below the drainfield rock for a 5' wide trench. Contractor shall verify this condition prior to placement of the rock. All pockets of unacceptable materials must be removed and replaced. MATERIAL SPECIFICATIONS: 1. Septic tanks must be constructed by a municipally approved septic tank manufacturer. 2. The following pipe materials are approved for use in septic system installations in the Municipality of Anchorage: Cast Iron (perforated and solid), ASTM D3034 or P.V.C. (perforated and solid), ASTM F810 or H.D.P.E. (perforated, but not solid) and ASTM D2662 or A.B.S. (perforated and solid). 3. Insulation shall be at least 2" thick extruded direct burial polystyrene (Dow Chemical Co. Styrofoam HI or equal). 4. Septic tank inlets and outlets shall be fitted with watertight couplings (Caulder, Femco, or equal). 5. A permeable geotextile fabric (Typar, Mirafl or equal) must be installed between the final drain rock layer and the native soil layer. 6. All drain rock shall be .5" to 2.5" in diameter with less than 3% passing the #200 sieve. SAND GRADATION: 1. Sand used to level the new absorption bed must have the following gradation: 50% Passed the No. 4 Sieve 2% Passed the No. 100 Sieve 1% Passed the No. 200 Sieve 2. The sand source must be approved prior to use. .... Lot 7, Block 3, Trails End October 7, 2005 Page 4 of 4 INSPECTIONS: Municipal Ordinance requires a minimum of two inspections. These inspections must be conducted under the supervision of a professional engineer registered in the State of Alaska. The first inspection must be conducted after the excavation of trenches, beds or pits and before the installation of any gravel. A septic tank may be set in place, but may not be backfilled. The second inspection must be conducted after the placement of the geotextile fabric, gravel, distribution piping, standpipes, cleanouts and insulation. No backfill should be in place at the time of inspection. Contractor shall provide a copy of all field survey layout and construction notes for use in preparing the certified as-built of the completed system. 10/20/2005 ~ 10:13 F,~ 907 343 8250 MOA RIG*ET OF WAY OFFICE POST IN A CONSPICUOUS PLACE ALL WORK MUST BE INSPECTED Field Inspection Request required 48 hours In advance of staxt wol'k and 48 hours in advance for final Inspection. Ca11(907) 343-8206 (voice recorder) for scheduling inspections. MUN'~ClPALITY OF ANCHORAGE RIGHT OF WAY DM$1ON 4700 SOUTH BRAGAW STREET TELEPHONE (907) 343-8240 FAX (SOT) ~4~-8250 RIGHT OF WAY PERMIT Type; ROW USE Date Applied: 06/06/2005 Construction Start Date: 0W00/0000 Permittee: BTH CONSTRUCTION, LLC Gen. Contractor. Utility Account: Primary Inspectm': WALTERS, MICHAEL S. Site Address: BROWDER AVENUE Subdivision: TRAIL'S END Work LocaUon: 11300 BROWDER AVE Status: OPEN Date Issued: 06/0C~/2005 Last Updated: 06/06/2005 Grid: 2641 Issued By: PINKSTON. MiKE ~002/004 2OO5O672 Latest CO#: 0 Contact: BRIAN HARTEN (907) 230-3992 Contact: Building/Land Use Permlt #; Cross Street: TRAIL STREET Lot: 7 BIock.rTract: 3 Orkjinal FRENCH DRAIN ON THE WEST SIDE OF BROWDER AVE AT LOT 7 Work Descrl~lon: Partial Road Closure: L..J Full Road Closure: I '1 TCP Required: [--] Pavement Break: Winter Requirements: Safety Devlc~ Requlred: Driveway; Approved Drawings: ~'~ Special Provisions: I I Other (aaa back): I I Traffic Control Plan Inf.or_m_.aflon (M. os.t__R.e.c_s_n~ Closure Type: From: To: Agencies Notified - Fire/Poilce: ~ State of AK: r-~ People Mover:. ~ School Bus: Approved?U Summarized Financial Transactions (as of 61612005) Lest payment date: 06,'06/2005 Total fees: S430.00 Total payments: $430.00 Total Prepay:. $230.00 See reverse for requirements I remarks I construction notes I special provisions. I have read en.d understand both sides of this pewniL I agree to the terms and conditions; and I certify that all v;ork wl comply w~th federal, state, and municipal codes and regulations and the prov s ohs of this pennR, 10/20/2005 THU 10:13 FAT 907 343 8250 ~0A RIGITT OF WAY OFFICE 1~003/004 CONSTRUC~ON. SEE DETAILS ~ PIPING AT BOSOM OF TRENCH DRA~N TO BE RUN~l: AT .5~ NOR~ TO SOU~.~ {:~::.::;:~:;. :::::~:C:{:: ~': 5' U~ii Eem[ I~ ~;;{;~ ~::~;~:;:;; OPEN DITCH ~O~ DA%IGHT ~ENCH DRAIN INTO~ EXIS~NG SWALE ~ERE SLOPE A~O~, GENERAL AREA SHO~, ' EXIS~NCcuL~R~ROAD LOT 7 BLOCK 3 R [:~:'~:~l~[[;[;]~:::[~:l :~:~:~ ~:~:~:~:~::~:~: ~:~:~:: ~~/~ ~ LOT 7 ~OCK ~ TRAIL'S E~D SU~DI~SIO~ P.O. BOX t103~ PRCPO~I) IH~CH DRA]~ PLaN 10/20/2005 TIPJ 10:14 FA~ 907 343 8250 ~OA RIGHT OF WAY OFFICE ~]004/004 PRO~CT NOT~$: CONSTRUCl10N OF' THIS 1RENCH DRAIN IS CONS~ST?...NT ~TH ~E O~L~ENT PAz I~NS ON ~E ~RROUN~NG PR~ER~E~ CONS~UC~ON ~ ~IS ~EN~ ~AIN ~ NOT AD~Y ~CT ~E E~NO D~OPUENT. OR P~T ~E g~T ~ ~JA~NT PR~ER~S. ~IS ~EN~ DRNN ~LL NOT ~UPR~ISE ~E ~JA~T RO~WAY ~D ~N~RSELY, ~ H~ TO KEEP ~E ~B-BA~ DRNNED. CEN~UNE ~ ~ ROAD ~A~ ~ /GRADE R~~O MATm ~6' P~FORA~ ~.~ hex II03~ PHOP05[O ~ENCtl D~AIN NO~S AND ~)k POST IN A CONSPICUOUS PLACE ALL WORK MUST BE INSPECTED Field Inspection Request required 48 hours In advance of start work and 48 hours In advance for final inspection. Call(907) 343-8206 (voice recorder) for scheduling nspect ons. · . MUNICIPALITY OF ANCHORAGE RIGHT OF WAY DMSION 4700 BRAGAW STREET TELEPHONE (907) 343-8240 FAX (907) 343-8250 RIGHT .OF WAY PERMIT Type: ROW USE Date Applied: 06/15/2006 Construction Start Date: 00106/0000 Permiltee: EARTHWORK SOLUTIONS, INC Gen. Contractor: Utility Account: Primary Inspector:. WALTERS, MICHAEL S. Site Address: 11300 BROWDER AVENUE Subdivision: TRAILS END Work Location: Status: OPEN Date Issued: 06/15/2006 Last Updated: 06/15/2006 Grid: 2641 NORTH OF TRAIL STREET. · ~o c n r ,~ ~epartment 20060643 Latest CO#: 0 Issued By: MOELLER, LAURA J. Contact: ScoTrA. MCLEOD (907) 562-5545 Contact: Building/Land Use Permit #: Cross Street: TRAIL STREET Lot: 7 Block/Tract: 3 Original INSTALL DRAIN AND ROCK IN EXISTING DITCH 25-FT EAST OF PROPERTY. INSTALL NEW Work Description: DRIVEWAY WITH NO CULVERT AT 11300 BROWDER AVENUE. Latest Work Description: Partial Road Closure: [] Full Road Closure: [] TCP Required: [] Closure Type: From: To: Pavement Break: [] Winter Requirements: [] Safety Device Required: [] Driveway:. Approved Drawings: Special Provisions: Traffic Control Plan Information (Most Recent) Agencies Notified - Fire/Police: [] State of AK: [] People Mover: [] School Bus: [] Summarized Financial Transactions (as of 6115/2006) Last payment date: 06/15/2006 Total fees: $780.00 Last payment comments: CREDIT CARD Other (see back): [] Approved? [] Total payments: $780.00 Total Prepay: $230.00 See reverse for requirements I remarks I construction notes I special provislons. I have read and understand both sides of this permit. I agree to the terms and conditions; and I certify that all work will comply with federal, state, and municipal codes and regular ons and the provisions of this permit. RIGHT OF WAY PERMIT 20060643 CO Construction Requirements and Notes: 1 - The pennittee shall post a copy ot the permit in a conspicuous location at the place to which the permit pertains before any work there is started and shall remove the permit only after the Right of Way Inspector has accepted Ihs wed¢ as being performed In compliance with the permit 2 - Aft construction shall be in accordance to the Municipality of Anchorage Staeda~ Specifications, (MASS), 1994 EdilJon, applicable municipal codes and regulations, and the approved drawings and special provisions of this permit 3 - Permanent paving, recycled asphalt pavement (RAP), chip seal, sidewalks and cod) and gutter must be replaced within 7 working days after underground work Is cornpleled 4 -This permit has been issued based on the assumption thai the information contained in the plans and supportJng information is correcL Any and all omissions ara the responsibility of the permittee. Any change in the scope of wod[ requlras a revised or new permit and TCP 5 - Permlttce is responsible for locating end protecting all utilities and survey markers In the work vicinity. For incat~ons, call 'Locate Call Center of AJaska'. (907) 278-3121 OR (800) 478-3121 6 - Ail underground installations within a public place shall be buried at a minimum depth of k~ty-two Inches (42') below the IJnal surface elevation. I.e., bottom of drainage ditches, road shoulder, or tinished grade ? - The r~ght of way shall be restored Io the same, If not better condition, than It was in prka' to the contractors work being performed. The work shall be performed vigorously and continuously, until completed to the satisfaction of the Municipal P3ght of Way Inspector 8 - Changes in the appeoved road ciosuras or scope of wo~ resulting fi-om emergency circumstances may be allowed during construction. It shall be the responsibility of the contractor to notify the Pem~tt Office 343-8206. and/or obtain an approved Traffic Control Plan (TCP). It shall be the contractor's responsibility to notify the following agencies: Fke Dispatch 267-4950. Police Dispatch 786-8900, A~aska State Tronpe~ Dispatch 428-7200, People Mover 3436543 and School Bus 742-1207 or 742-1209 9 - The contractor shall erect signs, benlcades and detours in accordance with the U.S. Department of Transportation 'Manual on Uniform Traffic Control Devices', Part VI - Traffic Controls for Street and Highway Constmc'tion, Maintenance. Utility and Emergency Operations. Failure to do so may result in tines being assessed under Title 14 ~or wod¢ not in confom~ance with a permit 10 - The Municipality has the right to Inspect and/or roject materials and wod~maeship not lo Municipal standards, to stop work unUI corrections are made. or to require removal of the facility and to charge time and equipment to the Pe~rnittee to con'eet the facility tf they fail co comply with the conditions of the permit 11 - Contractods acceptance of this permit constitutes acceptance of the Municipality's bonding requirements, and is contractods represents§on that contractor has and will comply with those requiraments. Unless a speci§c bond is applied to this permit by written reference, the contractors pedonnance bond on tile with Development Se~lces and Public Works. Right of Way Division, shall suffice as the required bond 12 - Special Previsions: N/A. 13 - Winter Requirements: 14 - Driveway Requirements: N/A. 15 o Other Requirements: ,O'Og ~..o', @~ '.U'(S3 "llifl .cj .O0'O~l 3,,00,00.00 N I§ mo Shebonof Avenue $89.06 IO]UI~ ~"mt 3 4 4 VACA,*4T VACANT S Trail Street NOTF.: AREA HAP SCALE 2' = I00' Woter F~v In Ditch AJohg East SkJe of Browder Avenue b Seoso*qol In Nature end Composed of Runoff. ~. ashed ~R=ck .to 3' Over Pipe NOTE: Th, Ends of the Sock Drain to be o Minimum of 100' Fram the Absorption Bed on Lot 7, Block 3, Trails End Subdlvls~on (Approximately 200') DITCH DETAIl NO SCALE 04/26/2006 89:44 98?-562-7883 POLAR ~L~PLY CO PAGE 83/84 Th~s specification applies to high density corrugated polyethylene pipe, Type C. Nominal sees for which this specification is acceptable are 75 - 600 mm (3 - 24 Inch) diameters. Requlrements for test methods, dimensions and rharklngs are found in AASHTO designation M-252 and M-294. Pipe and li~ings shall be made of vtrgln PE compounds ~hat conform with the requirements of cell classification 3354200 as defined and described In ^STM D-,.~50. Compounds that have higher cell classifications In one or more properties are accopt~t~le provided product requirements, are met. The minimum parallel plate stiffness values when tested In accordance with D-2412 shall be as follows: Dlar~eter Pipe SlJffness Diameter 1 l~iPo Stiffness . (nominal)' ' (m nlmum) · (nora rm.)I (minimum) 75 mm (3"} 240 kN/mz (35 I~ii) 250 mm (103 240 kN/m= (35 pii} 100 mm (4') 240 kN/rez (35 pll) 300 mm (12") 345 kN/mz (50 pii) 125 mm (5") 240 kN/mz (35 pli) 375 mm (15") 290 kN/m2 (42 pii) 1.50mm(6') 240kNlm= (35 pll} 450mm(18') 275kN/m= (40 p~l) 200 mm (8') 240 kN/m= (35 l~li) 600 mm (24") 235 kN/mz (34 pli) The pipe and fittings shall be free of foreign Inclusions and visible defects. For pipe sizes 300 mm (12 Inch) diameter and greater, designed drainage perforations shall be permitted in corrugation valleys only. All holes of any Idnd In the corrugation crests or sidewalls shall be considered unacc61:~table. Standard pedoratlons for 75 - 250 mm (3 - 10 Inch) shall be AASHTO M-252 Class 2 and for 300 - 600 mm (12 - 24'Inch) shall be AASHTO M-294 Class 2. The ends of the pipe shall be cut squarely and cleanly so as not to adversely affect Joining. The nomlnal size for the pipe and fittings is based on the nominal Insl~le diameter o! the pipe. Corrugated f'~tngs may be either molded or fabricated by the manufacturer. Fittings supplied by manufacturers griper than the supplier of the pipe shall not be permitted without approval of the Project Engineer. Joints for 75 - 150 mm (3"--6.1Q~;.h.) shall be made with snap Couplings. ,Joints for 200 - 600 mm (8 - 24 Inch) sba, Il be made wi~ split ~l.,'pling~.to engage the plpe corrug,tti.0ns. Installation shall be In accordance with A$~'~'"R~commended Practice I~-~"~ ~'r-~s specified by Ihs Pro~ect Engineer or local approval agency. A manulacturer's certification that the product was manufactured, tested and supplied in accordance with this specification shall be furnished to the Project Engineer upon request. 04/26/200G 89:44 907-562-7003 ~ SUPPLY CO PAGE: 82/84 '..'.~..'~'; ~ ;'~.""..." "!"'"'.:"' . i .... i~'.'...: --;. · .. -... f* ..~.... · '".: ~.-' .'..'~. ....~;~'2:'~,~ ;'~ '.~*~'?~ ~,.~.¢;. ..._... ~ . ~ ..... ,[~:~- ~ ~;r:.~ -. · ~ ..,,~:..:~¢?: ~ .'* ~.~,:,,~:,?.(..:~,: f:~ *." ~,.~D~]~:. ~H~'.~' :..;;,'~-~.~'~ *'. ~ ~-:-' ,..~ ....~,: '~. · ~,.:~.~. ~-.] ,.. ,~..:].~. ~.,~,~..,..,~., ....~0%t . .,,~.. ~ ~. ~ t .....(~0~7 ,...... , - ~;~,~.,~,.~t~:~..;?~l~,~;,~ ~r~, .' ,:~'~e : z-i,-~:~.,~ ..', J~t-~: .L:;~5'tO35., .- ,-" ' ,~:~m~rinch~.'.~+~'.:~,~[t,;~'.,,.. :' '~;~:~"~'~:~?~,~,1'~~:' .-d' "'' ~'1~00-~- ' . (¢F~ D~r~rm'~.;' I ' · . , ''~ '~.~'~;'~?~;-?'~{a.':'. . ,,~-~:I..~ -' ;.,,~.~' ~.' · :.r~-~ :. · .', .. . .~ ulv,l~.~ ,S~e ... ~ ~ ~.,...;,, ,,~.? · . ~ ...... .:....~ ...~. . .... (A~SM D 37e~:~,~;~-:; '1" ' , -": ":'" :;~ ~,, ,",~i~, - , ' ' ' ' ' - · ' ~"'"'" ..~Woa~[~,~b~,.~e~'~~l~.- ':. '..~:*.~.~i~;":..,~.~?jt:: ~ ' ~ ..*:'.~:. :;..? ?:':. · '~at~t~Dr~i~'t6~l~&~{~l~;.; ' . . :.' ,. : ' ,..~.~....-~ .'~-:~....'.';t ..,...~,.~.~ ~d~, ~S ~ ~e ~e~c ~ envelo~ for eve~ job. Each Is s~ong, non-biodegradable and gives you the ex- cellent filtering and soil stabilizing cham~erlsU~ you need. Bo~ D~IN GUARD and ADS SOCK perform equally well In ~e ground for ~e llfe of your drainage in- stallation. And, because ~ese materials are facto~ Installed on ADS pipe, ~u'll save ~luable labor cos~ In .,',' · the field. STANDARD FEATURES ADS DRAIN GUARD AND SOCK synthetic wrap materials -- admit fine silt and clay; restmln sands and coarse silts -- non-toxic, non-lrfltatlng -- inert in soil -- non- biodegradable -- resist alkalis and acids -- will not rot-- not affected by freezing or thawing -- confinu- ouslengths up to 5000'-- available for drainage pipe sizes from 3" to 24" diameter-- factory applied, ready for Installation -- lower labor costs In the field. 0412612006 09:44 907-562-7003 POLAR StJPPLY CO PAGE 0[/04 Product Notes Product Notg ..... / Re: ADS I~i'aln ~uar~f' and Sock Date: March 1, 20%/ '"~'"'-.-. Solutions to Tough Siltation Problems Now Advanced Drainage Systems offers you two ways to meet tough siltation challenges head on. These synthetic wrap materials combine with ADS corrugated polyethylene pipe to give en extra-strong, tough screen that stabilizes soils and keeps water flowing, Both feature opening sizes that have proven effective for moving water without blockage In a wide range of soils. The entire length of drain Is covered, and corrugations are spanned by the materials, maintaining effective Inlet areas which promote rapid drainage. For drainage in, radiations that requffe a tough, durable screen under normal h~ndltng condtUons: ~t~. DRAIN GUARD* protective wrap, a complete, ona-~tep drainage sys- tem for sandy and other problem soils, Installed with conventional drainege equlpment. For Jobs where the protective covering is subjected to unusually rough instoll. lailon and handling conditions: ~.SOCK a flexib~e drain envelope Ihst meets the needs of a wide range of soil conditions, Installed with conven- tional drainage equipment. Choose the ADS Synthetic envelope that's right for each job. ~/~. DRAIN GUARD' For normal routine Installations. Manufactured or' 100% nylon, tough and durable DRAIN GUARD WEIGHS Just 0,85 ounce per square yard. The material's unique bonding process gives you an ultraporous filter that restrains and stabilizes the soil, yet allows free entr7 of water. ~i~J~.SOCK For more rough, and-tumble Installatio~s. A polyester machine-knitted envelope [hat provides the needed water entry and sediment protection. SOCK weighs approximately three ounces per square yard. SOCK stretches to fit snugly ever [he pipe end gives ~he extra protections required by rough handling conditions, 464S TRUEMAN BLVD. HILLIARD, OH 4302a (800) 821-67t0 http'.#www..d~plpe.com 04/26/2006 09:44 907-562-7003 POI~ SLIMY CO PAGE~ 04/04 Municipality of Anchorage Development Services Department Building Safety Division ~ ~' ~*-~'~;:~ ~.~ ~ On-Site Water and Wastewater Program 4700 South Bragaw St. P.O. Box 196650 Anchorage. AK 99519-6650 www.ci.anchorage.ak.us (907) 343-7904 ON-SITE SEWER/VVELL SUBMITTAL COMMENT SHEET To: ANDERSON ENG Legal description: TRAILS END BL 3 LOT 7 The attached paperwork has been reviewed and is being returned for the following reasons: Original signature or stamp missing on Calculation error in design. Additional soils information needed. Water monitoring results inadequate. Discrepancy in information submitted. Topographic information missing or inadequate. Incomplete; missing Incomplete; missing Additional adequacy test information needed. Water sample unacceptable. __ Measured/proposed distances/dimensions missing. Locations of all soils, percolation and water monitoring tests not shown. Proposed system too deep for soils information submitted. __ Well log requir~ Omission in narrative. Insufficient fill over tank or field. Other. NEED PERMIT FROM RIGHT OF WAY FOR ROAD DITCH & ADDITIONAL GROUNDWATER MONITORING OF PROPOSED SEPTIC AREA THRU MAY 15m~ Name of reviewer: JOE GOODALL Date: 5/11/2006 Please supply the necessary information and re-submit your request. LEAVE THIS FORM ATTACHED TO THE PAPERWORK Municipality of Anchorage Development Services Department Building Safety Division On-Site Water and Wastewater Program 4700 South Bragaw St. P.O. Box 196650 Anchorage, AK 99519-6650 www.ci.anchorage.ak.us (907) 343-7904 ON-SITE SEWEPJVVELL SUBMITTAL COMMENT SHEET To: ANDERSON ENGINEERING Legal description: TRAILS END BLOCK 3 LOT 7 The attached paperwork has been reviewed and Is being returned for the following reasons: Original signature or stamp missing on Calculation error in design. Additional soils information needed. Water monitoring results inadequate..__ Discrepancy in information submitted. Topographic information missing or inadequate. Incomplete; missing Incomplete; missing Additional adequacy test information needed. Water sample unacceptable. Measured/proposed distances/dimensions missing. Locations of all soils, percolation and water monitoring tests not shown. Proposed system too deep for soils information submitted. Well log required. Omission in narrative..__ Insufficient fill over tank or field. [] Other. PLEASE SEE MIKE ANDERSON'S 30 SCALE SITE PLAN ATI'ACHED. 'ALL SURFACE WATER MUST BE A MINIMUM OF 100 FEET FROM ALL COMPONENTS OF SEPTIC SYSTEM & ALTERNATE SITE. GRADING AND DITCHING WILL BE REQUIRED." MIKE ANDERSON REQUIRES GRADING AND DITCHING TO BE DONE TO MAINTAIN 100 FOOT SETBACK FROM ANY SURFACE WATER, ALL SURFACE WATER ISSUES NEED BE APPROVED BY MIKE ANDERSON PRIOR TO AN ISSUANCE OF SEPTIC PERMIT. MIKE ANDERSON'S 30 SCALE SITE PLAN MISSING STAMP AND SIGNATURE Name of reviewer: JOE GOODALL Date: 2/2112006 P/ease supply the necessary information and re-submit your request. Municipality of Anchorage Development Services Department Building Safety Division On-Site Water and Wastewater Program 4700 South Bragaw St. P,O. Box 196650 Anchorage, AK 99519-6650 www.ci.anchorage.ak.us (9O7) 343-79O4 ON-SITE SEWERJVVELL SUBMITTAL COMMENT SHEET To: ~,NDERSON ENGINEERING Legal description: TRAILS END BLOCK 3 LOT 7 The attached paperwork has been reviewed and is being returned for the following reasons: Original signature or stamp missing on Calculation error in design. Additional soils information needed. Water monitoring results inadequate. Discrepancy in information submitted. Topographic information missing or inadequate. Incomplete; missing Incomplete; missing Additional adequacy test information needed. Water sample unacceptable. Measured/proposed distances/dimensions missing. Locations of all soils, percolation and water monitoring tests not shown. Proposed system too deep for soils information submitted. Well log required. Omission in narrative. Insufficient fill over tank or field. [] Other..NEED MAINTENANCE AGREEMENT. -THE SITE PLAN NEED TO SHOW MEASURED DISTANCES TO ALL WASTE'WATER DISPOSAL SYSTEMS, WELLS, SURFACE WATER OR DRAINAGE COURSES, ROADS, PROPERTY LINES AND STRUCTURES WITHIN 200 FEET OF THE LOCATION OF ANY EXISTING OR PROPOSED ON-SITE WASTEWATER DISPOSAL SYSTEMS. Name of r'e~ew~r: .JOE GOODALL Da{e: 10/24/2005 Please supply the necessary information and re-submit your request. Oct. 19, 2006 3:01PM anderson engineering No. 2698 P. 1 DATE: TO: WITH: FROM: SUBJECT: MESSAGE: Jeff: FAX MEMO 1011912006 Jeff Poet DHHS Mike Anderson Lot 7, Block 3, Trails End Subdivlslon Attached is the revised location for the well. It has been moved 10' further to the east and 10' further south. I have moved the alt=mate site on Lot 3 to where it Is now 40' from the property line. It looks like everythlng will work. Let me know If you have any questions. .3Pages Being Transmitted. Please call 522-7773 if not complete. 0ct. 19. 2006 3:02PM anderson engineering No. 2698 P. 2 0ct. 19. 2006 3:02PM anderson en~ineerlng No. 2698 P. 3 Municipality of Anchorage ::~:~ Development Services Department.'~,~,:" ~' Building Safety Divfsion ,,~,, On-Site Water and Wastewater Program, 4700 Elmora Road-- P.O. Box 196650 Anchorage. AK 99507 Page of www. cJ.anchorage.sk.us (907) 343-7904 ON-SITE WASTEWATER DISPOSAL SYSTEM AND/OR WELL INSPECTION REPORT Permit Number. Sw060158 PID Number. 015-191-44 Innovative Building Solutions Wastewater System: [] New [] Upgrade 17510 Snowcrest Lane Anchorage, AK 99516 ABSORPTION FIELD 929-4922 3 ODe~Tn,,'~ OS~o~rm,~'~ Os,~ E3Mo,~ LEGAL DESCRIPTION 4 o~o~e ~.5 I~ 3 ~'~ 7A Su~,~et Trails End 0 ri. .5 rt 4-5 r~. 20 F~. Well: [] New [] Upgrade a~,*~ 10 F,. "'~'~ ~"3 I ~'~"~ ~"~"'3'5 Pdvate 226 ~. 92 F~ 200 re ASTM D3034 PVC Alpine Drilling 4/7/07 0 F~ Alaska Excavating 7110-11/2007 20 o~M "' ~. >1.5 r~ TANK SEPARATION DISTANCES ri Septic [] Holding [] S.T.E.P. 1'~ Other: w,~ >100' >100' >100' N/A >25' Steel Two {2) s~,w,,, >1oo' >1oo' >1oo' N/A ~ ~ LIFT STATION Fo~t,~ >5' >10' >5' N/A 28 ,, 28 ~] 32 ~ m'~n >20' >20' >20' N/A Orenco Model 20 Municipality of Anchorage See Lot Line Waiver. BENCH MARK Landscaping Over Mount to be Completed by 6/15/09. Garage Slab Inspections performed by: ~EA Dates: 1~ 7/10/07 Development Services Department Approval *' ~' --- '~ ~'.: 49~_:.-~ Reviewed and approved by: Date: qJ j ?,~0f[$S~.e,, Municipality of Anchorage DEVEOPMENT SERVICES DEPARTMENT 4700 Elmore Road Anchorage, AK. 99519-6655 - 343-7904 On-Site Wastewater Disposal System or Well Inspection Report Permit No.: SW060158 Page 3 of 3 PID No. 015-191-44 PROFILE AS-BUILT ScaPe: NONE SGS Ref.# 1091438001 Client ,Name Anderson Engineering Printed Date/Time 04/20/2009 9:58 Project Name/# Lot 7, Block 3, Trails End Collected Date/Time 04/13/2009 14:20 Client Sample ID Lot 7, Block 3, Trails End Received Dale/Time 04/13/2009 15:40 ~latrix Drinking Water Technical Director Stephen C. Ede PWSID 0 Sample Remarks: Allowable Prep Analysis Parameter Resu~ L~ POL Uni~ Method Comamer iD Limi~ Date Date Init Metals b~' ICP/NS Arscnic ND 5.00 ug/L EP200.8 C (<10) 04114/09 04/16/09 NRB Waters Department To~l N[u~tWNi~tc-N 2.28 0.100 mg/L SM204500NO3-F B (<10) 04/17/09 JDZ M~crobioloc~, ~aborato~r Colony Count 0 Toul Coli~rm 0 Fecal Coli~rm 0 c01/100mL SM20 9222B A (<200) col/100mL SM20 9222B A (<1) col/100mL SM20 9222B A (<1) 04/13/09 DLC 04/13/09 DLC 04/13/09 DLC 2of4 N 00'00'00'£ 120.00' 5' UTIL. ESMT. 30.5' 28.9' N 00'00'00'£ 20.00' BROWDER AVENUE