Loading...
HomeMy WebLinkAboutSOUTHFORK NORTH BLK 4 LT 10outhfork North Block 4 Lot 10 #078-141-24 • .. Municipality of Anchorage Development Services Department Building Safety Division A ' On -Site Water and Wastewater Program, 4700 S. Bregaw St P.O. Box 196650 Anchorage, AK 99519-6650 Pagel of 2 www.ci.anchorage.ak.us (907) 343-7904 ON-SITE WASTEWATER DISPOSAL SYSTEM AND/OR WELL INSPECTION REPORT Permit Number. SWO60062 PID Number. 078-141-24 No" Wastewater System: EINew ❑ Upgrade "aei" )WHIE DR. EAGLE RMR ABSORPTION FIELD ". Huner of e.aoan. O D..n TI«cn ® SMO Trial D Old 0 L^M 0 Ottw sod Ftm v Tar DOOM Mao agrol arr1R LEGAL DESCRIPTION 0.8 GPD/F? 8.5 FL el&* Lot eIOONFgn D•PIMb PM Roean Ram aig�^•1 W C/Rwl aeFlll DalrM PM 4 10 SOUTHFORK NORTH +1-3.5 FI. 4.5 FI Np Brwl Kg* sma Fe ea000 auwt, wiaw V•a0 creLrgm 0.5 Ft. 56 FI. Tawn rxRvr rMM H- � W IM D�rU%R RRIWRM was Well: ® New ❑ Upgrade 5 Ft. 1 0 Ft cW'&f 1PmrR. A B. c)' Tar o.Pm Cu.a b TWr tl.aPem r'.� 5 6 0 W FP ASTM 3034 PRIVATE 73 Ft. 72 FL �y0 D,ar� DRU (XdW Suter Wrr LRrr FMrur Dal YMHr4a BILL SULNAN 612912006 35 FL GREY'S CONSTURCTION 711012006 Y+ Pump sr r C .a ComV HRight Aoo.R Dour TANK s DPM 6 I Ft. 2 Ft SEPARATION DISTANCES 0 septic ❑ Holding ❑ S.T.E.P. 0 Other. To Septic Absorption Lift Holding ublWF`rivate WWW SIT From Tank Field Station Tank sewer Line ANCHORAGETANK 1000 Dr Mrrw Humor a co-wmrn. w" +100' +100' — — +25' STEEL 2 se"wew +100' +100' — — LIFT STATION Sao adur LW t„O +5 +10' — —V NO LIFT Dr 'Pa.p R11I•vrr -PI WFN 0High"IV rrmr cutin Dion +5' +10' — — u•DMMIn M ti 50 PR♦Moat Elrxncr n.P•Wwrn Prlom'•a RY cun Drrn +50 +50 — R~, BENCH MARK DRAINFIELD WAS INSTALLED IN SOILS CONSRENT WITH SOILS Loutwn rr pRFaplwn LOGGED AND TESTED. BOTTOM STEP OFF SHED rm.o NvRuon 100 FL Engineer's Stamp Inspections performed by: CHARLES BALZARINI Dates: 1' 71612006 2ne 711012006 i Development Services partment Approval WRISTOPMRWDOD � CE , • 1�3 7 Reviewed and approved by: Date: 5� � % .' IRV ILWI Eagle River Engineering Services Christopher R. Wood, P.E. PO box 773664 (907) 694-5195 tel Eaele River, AK 99577 (907) 694-3297 fax September 17, 2008 Deb Wockenfuss MOA Development Services Department On -Site Water and Wastewater Program 4700 Elmore St. RE: South Fork North Lot 10 Block 4 Dear Ms. Wockenfuss, The following memo is to address the review comments issued on the inspection report for this property 1) Grey's Construction is OK as an installer, per Dan Roth. 2) Please see visual depiction of water monitor tube vs. perc test location on revised Inspection report. 3) Homeowner will provide this information to On-site. 4) Tank has 2" insulation plus 3' fill, as shown on revised Inspection Report. 5) Separation distances have been added. 6) Absorption Area has been updated. Please contact us if you have any questions, or require further clarification. Sincerely, EAGLE R VER ENGINEERING SERVICES 049j�-_l Christopher R. Wood, P.E. Permit No. SWO60062 Page 2 of 2 Municipality of Anchorage DEVELOPMENT SERVICES DEPARTMENT ON—SITE WATER & WASTEWATER PROGRAM 4700 SOUTH BRAGAW STREET P.O. BOX 196650, ANCHORAGE, AK 99519-6650 On—Site Wastewater Disposal System and/or Well Inspection Report Legol Description: SOUTHFORK NORTH LOT 10 BLOCK 4 078-141-24 LOT 10+ N J y / 4 - SHED + B.1� wAY • � s • , OR1VE 6 • o � t 5'X56'RESERVE�j' LOCATION OF DEEP AREA F o )W GROUND WATERrr B MONITORING TUBE D s LOCATION OF SHALLOW !� m NOVS'c PERC TEST BENCH WELL $ Z 1000 tiAL 36 SEPTIC TANK 5'X56' — CLEANOUT E M T+,y71S — WELL TTOM STEP FF SHED D MONITOR TUBE ASSUMED ELEVATION • 100' ELEVATIONS ORIGINAL GROUND (NOT TO SCALE) LEVEL AT, 101.4 MT -1 FILL MT -2 \ TH-1 A .5' ISULffl10N' 3'5 8.2� YPAa 97.4 TANK.o.oo . •• ND .V.T.•4. oo98.5• GRAVED . • ' • ?e ° o, 92.9 86.4 .o BOTTOM OF T.H. 6/2006 ENGINEER'S SEAL 9000�p�0 �F,• OF At 4 CHMSTOPHER R. NV00.• J'• CE -10387 04/27/2007 12:46 6882259 SLLLIVAN PAGE 01/01 uCertif f eb ;3riffing log by ooc co. dba SULLIVAN WATER WELLS P.O. BOX 670272, CHUGIAK, ALASKA 99567 •TELEPHONE 686.2759 OWNER OF LAND: JCR rvWY D I-OLA&Ml 1 ADDRESS: LEGAL DESCRIPTIONS, -MI Ao4 r rUOrTti DATE: PERMIT NUMBER: D 6M Q- Date of lssueY— -i 4-" TAX IDENTIFICATION NUMBER. 0—la-11q1Z�_-alq Is well located at approved permit location? Q'Qes 0 No Method o1 Drilling: r rotary 0 cable tool Depth of well: -70 Casing Typer/ a `' Wall Thicknesses Inches Diameter Inches, depth —7A• feet Liner Type: ht a s.3„ Casing Stickup Above Ground: r1 • feet Static Water Level: :?j feet Recover Rate: (o gpm Method of Testing: j4 iA- Well Intake Opening Type: pen end O open hole 0 Screened: Startfeet Stopped feet 0 Perforations Start feet Stopped .� C.N!/1 GroutType:%f;.J$ o Volume Depth: from e> feet, to X a feet Well Disinfected Upon Completion? 6-f s 0 No Method of Disinfection: t�ll� a sr. �lrx' tM 00/0.+t feet Comments: tS J&e AJW4,-� I-1i4.c 1'q'j ico08ke-� I�I�Kd�i4� '� ISJ 1r4AFr�s Driller's Name ATTENTION: It is the responsibility of the property owner to submit a copy of the well lop to the proper authority. Municipality of Anchorage: Department of Health & Human Services and/or Department of Environmental Conservation. Matsu Borough: Department of Environmental Conservation. ARCTIC PUMP & WELL INC. Jim Sullivan, CPI PO Box 770197 II 11 Eagle River, AK 99577 (907) 688-2510 (907)258-2510 (907)745-2510 nmv n eci net Pump Installation Log Well Drilling Permit Number: SW060062 Parcel Identification Number: 078-141-24 Date of Issue: 4-19-06 Legal Description:Southfork N Property Owner Name B. Address: Lot: 10 John Ilollaway Block:9 2218 N River Drive P.M. Rivor AU ooe77 Pump Installation Date: 7-23-08 Pump Intake Depth Below Top of Well Casing:61.2 Feet Pump Manufacturer's Name: Flotec Pump Modcl:FP3212-09 Pump Size:1/2 hp Pitless Adapter Burial Depth:11.2 feet Pitless Adapter Manufacturer's Name:Martinson M310 Pitless Adapter Installer: Arctic Pump & Well, Inc. Well Disinfected Upon Completion? Yes Method of Disinfection: Chlorine Comments: Pump Installer Name: Arctic Pump & Well, Inc. Arctic PUMP & Well, Inc. Page I of I MUNICIPALITY OF ANCHORAGE Development Services Department Onsite Water d Wastewater Program 4700 South Bragaw Street P.O. Box 196650, Anchorage, AK 99519.6650 (907) 343-7904 ON-SITE WASTEWATER DISPOSAL SYSTEM / WATER SUPPLY PERMIT Renewal Permit Number: SW060062 Date Issued: Apr 19, 2006 Expiration Date: Apr 19, 2007 Parcel ID: 078-141-24 Legal Description: SOUTHFORK NORTH SUBDIVISION BLOCK 4 LOT 10 Design Engineer: 0848 EAGLE RIVER ENGINEERING SEI Owner Name: JOHN HOLLAWAY Owner Address: 2218 NORTH RIVER CIRCLE EAGLE RIVER. AK 99577 - Site Address: 2218 NORTH RIVER CIRCLE Lot Size: 97831 SO. FT. Total Bedrooms: 3 Permit Bedrooms: 3 This permit Is for the construction of: ❑✓ Disposal Field ❑✓ Septic Tank ❑ Holding Tank ❑ Privy ❑✓ Private Well ❑ Water Storage All construction must be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal Code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72 ) and Drinking Water Regulations (18AAC80 ). 3, The engineer must notify DSD at least 2 hours prior to each Inspection. Provide notification by calling (907) 343-7904 ( 24 hours ). ( Not required for a Water Supply Permit only ). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must be either: A. Open and closed on the same day. B. Covered, sealed, and heated to prevent freezing. 5. The following special provisions. LOCATION OF WELL ON ENGINEERS SITE PLAN DATED 1/9/06, IS THE PERMITTED LOCATION OF WELL. Received I Issued By: =0491900 Date: 4,111,112V Municipality of Anchorage Development Services Department Building Safety Division On -Site / Water and Wastewater Program 4700 Bragaw Street P.O. Box 196650 Anchorage, AK 99519-6650 www.muni.orglonsite (907)343-7904 ON-SITE SEPTIC/WELL PERMIT APPLICATION FOR A SINGLE FAMILY DWELLING 1)767111-2-4-o007rod n Parcel I.D., Property owr Mailing adds Site address phone ` 4,)—T73_ Code Code99 5-77 Legal description (Sub'd, Block & Lot) Legal description (Township, Section Lot Size 9 -47 q 3 I Sq. Ft. THIS APPLICATION IS FOR (®all that apply): Absorption Field Q Septic Tank l Holding Tank ❑ Privy ❑ Private Well Water Storage ❑ Number of Bedrooms 3 THIS APPLICATION IS AN: Initial ❑ Upgrade ❑ Renewal 9 certify that the above information is correct. 1 further certify that this application is being made for a Single Family Dwelling and is)r9 accordance with applicable Mugcipal Codes. (Signature of property owneryr-606rized agent) Permit/Rush Fees: Date of Payment: Receipt Number: (Rev. 11105) Waiver Fees: Date of Payment: Receipt Number: Municipality Of Anchorage ° Po. Box 19GG50 • Amboragc. Alaska 99519-GG50 • Tcicpl,m,c (907) 343.5301 • Pax (907) &S3.62(X) < � .: 4700 Iimpw Strcel •:lnchnm¢c, :Unsla 99507 s. e.. _-" aI"c.mMl.org Mayor Hark Begich i3tiading Safety Division January 17, 2006 John & Sylvia Hollaway, Jr. 22222 Brownie Drive Eagle River, Alaska 99577 Re: Water Supply Permit SW050122 Southfork North Subdivision Block 4 Lot 10 Dear Mr. & Mrs. Hollaway, Thank you for the site plan submitted to this office on January 9, 2006 showing a new location for a water well to serve the subject property. Because of this new proposed location of the water well the subject permit has been reinstated. If you have questions on the above please contact me at 343-7907. Sincerely, f Daniel J. R th Program Manager On -Site Water & Wastewater Program cc: Chris Wood, PE, Eagle River Engineering Services Kristin Cada, Deputy Ombudsman Community, Security, Prosperity Daniel J. Roth Program Manager On -Site Water & Wastewater Program I have received your letter rescinding my well permit SW050122 and believe that action is in error. My permit was issued using all available data known to your office and my Engineer. Your acceptance of a later permit submission and approval of that permit has now impacted development of my property and lead to your decision to rescind my well permit. The data used in this later permit submission has been available since 2003, but withheld from your office and therefor not available to me or my Engincer. AMC 15.55.050.C. provides the basis for the Director to revoke, suspend, and restrict permits approved. 1- No false statements were made in my permit, 2- No violations of the permit terms were made, 3- No act or omission violating requirements of AMC15.55 where made, and 4- There has been no failure to comply with state or federal regulations. Your action to rescind my permit is not supported by AMC I5.55.050.C. I can fmd no other provision allowing or requiring you to rescind my permit. Your acceptance of a later permit submission, providing data previously withheld from your office, in favor of my approved permit, must be reversed. AMC I5.55.050.A.3. provides a one year expiration for well permits. My permit was issued to expire in May 2006. Please re -instate my permit without further delay. Sincerelyy`� .12/8/05 John H. Hollaway 22222 Brownie Drive Eagle River, AK 99577 cc: Chris Wood, PE, Eagle River Engineering Services cc: Kristi Cada, Deputy Ombudsman DEC -05-2005 03:52 PM ATTENTION: DAN ROTH, ON-SITE WATER AND WASTE WATER Chris Wood, PE Eagle River Engineering 10421 VFW Rd, STE 201 Eagle River, AK 99577 Three of the five test holes certified by Jeff Garness, PE, for use in the soil log and percolation testing provided the Muni for Block 4, Lot 11, of South Fork North subdivision are located on my property, (Block 4, Lot 10). Test hole 04 has now beeti'certified by Brian Harten, PE and incorporated into a septic system design submitted to the Muni. I have Identified this discrepancy to Mr. Dan Roth of the Muni on-site office. He explained to me that Brian Harten, PE had certified the submission and that if you identified the discrepancy he could then act on it. I don't understand why he requites you, to make this known to his office. Mark Seward petfbrmed the survey and test holes 1,2, and 4 aro clearly on my lot, or dissected by the property line with more than balf on my side. As a side note for my reference, could the results of test holes # 1,2, and 4 be used by the for any future on site designs for Block 4, Lot 10., or is there a limit to how long ago the tests wbere performed? Mr. Dan Roth of on-site has advised me to take no action to install a well under my currently approved permits, and to expect a stop work notice In the mail. I contest the stop work notice and the grounds used to take this action. The submission for Blk 4, Lot 11, arrived We and long after my approved permits. The submission for Blk 4, Lot I I is based in part on the performance of my soils and must not be accepted as usable for permitting. I have had an approved permit for some time Dow and had to this point delayed implementation for convenience. I desire to install the well at this time, without Auther delay. I require a meeting with you on these concerns and ask that no changes be made to my permits. SI V4 John H. Hollaway Jr. 22222 Brownie Drive Eagle River, AK 99577 cc. Dan Roth cc. Mark Seward cc. Anna Fairclough P.01 Aluideipality of Anehorage \C l , �' i / P.U. Box 196650 t Anclhomgc, Alaslut 99.i19.6rsi0 t Telephone (1107) 34&&9(11 t Fac (ltt)7) 333.6'(X) (Y.607 �, 4700 Bmgaa• Stmet t ,Utchongc, Alaska Mayor Mark Begich .".,�.ma��l.arg BitUding Safety Division November 30, 2005 John & Sylvia Hollaway, Jr. 22222 Brownie Drive Eagle River, Alaska 99577 Re: Water Supply Permit SWO50122 Southfork North Subdivision Block 4 Lot 10 Dear Mr. & Mrs. Hollaway, At this time the water well portion of the subject permit has been rescinded. This letter will serve as your notice that you do not have a valid permit to drill the water well in the proposed location. Anchorage Municipal Code (AMC) 15.55 does not allow a water well to be constructed on a property in such a way that it AU prohibit the future development of an adjoining property with a conventional 'wastewater disposal system. The engineer, Brian Harten, PE, has been hired to design a wastewater disposal system to serve Lot 11, the property adjoining yours. He has determined through soils testing that the only practical location of a wastewater system will be in an area that is within the 100 foot radius of the proposed water well location on your property. Reinstating the water well portion of your permit will require you to authorize your engineer to resubmit a design plan of your property. This design plan should show a new location for a water well to be constructed on your property that will not preclude the proposed wastewater disposal system site on the adjoining Lot 11. If you have questions on the above please contact me at 343-7907. Sincerely, 1 ;P1-/� Daniel J. Roth Program Manager On -Site Water & Wastewater Program cc: Chris Wood, PE, Eagle River Engineering Services Community, Security, Prosperity MUNICIPALITY OF ANCHORAGE Development Services Department Onsite Water Q Wastewater Program 4700 South Bragaw Street P.O. Box 196650, Anchorage, AK 99519-6650 (907) 343-7904 ON-SITE WASTEWATER DISPOSAL SYSTEM I WATER SUPPLY PERMIT Initial Permit Number: SWO50122 Date Issued: May 16, 2005 Expiration Date: May 16, 2006 Parcel ID: 078-141-24 Legal Description: SOUTHFORK NORTH SUBDIVISION BLOCK 4 LOT 10 Design Engineer: 0848 Eagle River Engineering Services Site Address: 2218 NORTH RIVER CIRCLE Owner Name: JOHN HOLLAWAY Lot Size: 97831 SO. FT. Owner Address: 2218 NORTH RIVER CIRCLE Total Bedrooms: 3 Permit Bedrooms: 3 EAGLE RIVER. AK 99577 - This permit is for the construction of: ❑✓ Disposal Field ❑✓ Septic Tank ❑ Holding Tank ❑ Privy ❑✓ Private Well ❑ Water Storage All construction must be in accordance with: 1. The attached approved design. 2. All requirements specked in Anchorage Municipal Code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations ( 18AAC72 ) and Drinking Water Regulations (18AAC80 ). 3, The engineer must notify DSD at least 2 hours prior to each Inspection. Provide notification by calling (907) 343-7904 ( 24 hours ). ( Not required for a Water Supply Permit only ). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must be either: A. Open and closed on the same day. B. Covered, sealed, and heated to prevent freezing. Received By: "Z/Z10�_ Date: Issued BDate: a6 1 -1Ti� Municipality of Anchorage Development Services Department Building Safety Division _ On -Site Water and Wastewater Program 4700 South Bragaw St. P.O. Box 196650 Anchorage, AK 99519-6650 www.ci.anchorage.ek.us (907) 343-7904 ON-SITE SEWERMELL PERMIT APPLICATION FOR A SINGLE FAMILY DWELLING Parcel I.D. /r:iq8- xll-�2, Permit Number SW Property owner(s) Day phone Mailing address (1) 227-22 61zewo r'6 DR, Mailing address (2) &A -CIA- f?Tt)&,YZ Ar `19577 Zip Code Legal description (Lot, Block & Sub'd.) SovRtt FORK— AjoRT►i Ski DoT ro a t-oc-y Legal description (Section, Township & Range) T 1 3 Al R / kl Se G q Lot Size Q7$51 Acre Sq.FL Number of Bedrooms THIS APPLICATION IS FOR: 3 Sewer Only ❑�,/ ElWell Only Ly Sewer and Well Water Storage ❑ Sewer Upgrade ❑ THIS PROPERTY CONTAINS: Hot Tub ❑ Jacuzzi ❑ Swimming Pool ❑ Water Softening Unit ❑ Therapy Pool ❑ I certify that the above information is correct. I further certify that this application is being made for a Single Family Dwdfling and,islA accoronce withypplicable Municipal Codes. (Signature of property owner or authorized Permit Fees: 4b0 rD } 19ci' tD Waiver Fees: Date of Payment: 6-11(105 Date of Payment: Receipt Number: %� i Receipt Number: (Rev. 72/00) Eagle River Engineering Services Christopher R. Wood, P.E. 10421 VFW RD. Suite 201 Eagle River, AK 99577 May 11, 2005 Dan Roth Manager, On -Site Services Municipality of Anchorage P.O. Box 196650 Anchorage, AK 99519 Re: Southfork North B 4 Lot 10 Narrative & Permit Application Dear Mr. Roth: (907) 694-5195 tel (9o7) 694-3297 fax Eagle River Engineering Services (ERES) was contracted to obtain a septic and well permit for a 3 bedroom single family home at the above referenced property. The proposed septic system will have very limited impact on adjacent properties for the following reasons: 1. The surrounding lots are all relatively large, so there is ample room for wells, septic systems and alternate sites. 2. Immediate neighboring septic systems are all +20' distance, and no private (or community) wells within 200' of the proposed septic system. 3. This permit is for a well and septic system. 4. Drainage will not be affected and is not a major consideration in our design. Development of this lot will not adversely affect the wells or septic systems or reserve areas on adjacent developed lots, or prohibit development on large, adjacent undeveloped lots. If you have any questions please call our office at 694-5195. Sincerely, Christopher R. Wood, P.E. Principal \2003\05-011 SEPTICNARRATIVE Eagle River Engineering Services Christopher R. Wood, P.E. 10421 VFW Rd. Suite 201 Eagle River, AK 99577 (907) 694-5195 tel (907) 694-3297 fax SPECIFICATIONS FOR ON-SITE SEPTIC SYSTEM LEGAL: South Fork North B 4 Lot 10 May 11, 2005 A. GENERAL 1. The well and septic plan is for a 3 bedroom single family residence only. 2. The drawing and or site plan shall be a part of this specification. 3. All materials and workmanship shall meet the Anchorage Department of Health and State Department of Environmental Conservation requirements. 4. All soil tests are advisory to the design and are to be verified or modified in the field by the engineer. 5. All excavations and depths are advisory and are to be verified in the field by the contractor to meet Municipality of Anchorage, Department of Environmental Conservation requirements. 6. It is the responsibility of the owner to obtain all necessary permits or easements and to locate any adjacent multi -family wells. 7. The excavation is to be exactly in the area shown on the site plan, any deviation requires engineer approval. 8. Any remaining open test hole excavations shall be filled and monitor tube removed. B. SEPTIC TANK 1. The sewer piping from the house shall be 4" PVC 3034 laid at 2% grade maximum — 1% minimum and insulated with 2" of burial foam if shallower than 3 R., with 2 fl. minimum. A foundation cleanout shall be installed within 4' of the house foundation. 2. The septic tank shall be an Anchorage Tank 1,000 gallon 2 chambered septic tank. Contractor may submit alternate tank and for approval, as long as it meets MOA requirements. Two opposing after - tank cleanouts shall be installed. C. DRAWFIELD TRENCH 1. The drainfield is to be located as shown on the site plan. 2. The total depth of the initial drainfield excavation is to be 9' max. relative to existing ground elevation at ground water monitor tube. The bottom of the drainfield shall be level, plus or minus 1.5". 3. A 4 foot layer of sewer rock is to be placed over the native sand and gravel. The 4" effluent piping is to be laid on top of the gravel layer with, with 6" additional gravel added as follows: 4" along sides of effluent pipe, and 2" of gravel cover over the piping. 4. The completed drainfield gravel and piping is to be covered with lypar fabric material. 5. Soil or combination of soil and extruded board insulation to a depth of +3' or equivalent is to be placed over the leachfield. Soil shall be mounded over the trench to prevent runoff from ponding. Continued on next page \\Eres\dm\WPD0CS\2005\05-0l ldrainficid- spcc.doc Eagle River Engineering Services Christopher R. Wood, P.E. 10421 VFW Rd. Suite 201 Eagle River, AK 99577 Continued: RECOMMENDED LEACHFIELD DIMENSIONS: (907) 694-5195 tel (907) 694-3297 fax TOTAL DEPTII = 9' GRAVEL DEPTH = 4' under effluent pipe, 2" over pipe DRAINFIELD LENGTH = 56' DRAINFIELD WIDTH = 5' SOIL RATING= 0.8 GPD/fl? BEDROOM CAPACITY= 3 SEPTIC TANK= 1,000 gallons EFFLUENT PIPE= 4" diameter of Muni and Engineer approved materials and construction Twenty-four (24) hours notice required for all inspections. \\Ercs\docs\WPD0CS\2005\05-0I I drainficld- spcc.doc EAGLE RIVER ENGINEERING SERVICES 10421 VFW RD Suite 201 Eagle River, Alaska 99577 (907)694.5195 ERES Project No.: 05-011 Calculated By. CW Date: 5/11/2005 Legal: South Fork North Block 4 Lot 10 TEST HOLE 2 Single Family 3 Bedroom Dwelling Shallow Trench Subsurface Wastewater Disposal Field Water use at 150 gallons per bedroom = 450 gallons Percolation rate = 11 minutes per inch Wastewater application rate = 0.8 gallons per day per square foot Required absorption area = 583 square feet Trench width (W) = 5 feet Gravel depth (D) = 4 feel Required length = Shallow trench factor • Required absorption area / W Shallow trench factor = (W + 2) / (W + 1 +2 D) Shallow trench factor = 0.50 Total Excavation Depth = 8.5 feet Required length = 58 feet "11.7i�n i• ��� r �c�: 05-011 drainfieldCalc 11:48 AM5/11/2005 (�EV�jc� D�slSrJ . 2' t. ,a I �aON R 3AIa0 MAN ah' nit . r� oo• yy F- 0 o EK O z ` 1U 00-1. 9PO OSO f s or .. I or 3, 00 ' O W co L)_ V SCO 0040' df �203:2nCL.Lio J CL i Is o EK O z ` 1U 00-1. 9PO OSO f s 00 O W co L)_ V SCO W i < df �203:2nCL.Lio J CL i o W. W � VI N m W z zz W O o Y � J O U 00 O W co L)_ V SCO W i < df �203:2nCL.Lio 00 Municipality of Anchorage Development Services Department Building Safety Division • �.t On -Site Water and Wastewater Program 4700 South Bragaw SL P.O. Bax 196650 Anchorage. AK 99319.6650 wwvr.d.anchoraee ak us (907) 3417904 Soils Log - Percolation Test Performed For. --e) H , r 144-t r. oro s4 y Date Performed:_ g"/,47 /0Y Legal Description: - , 17 1,,1 s A - ..>,\. o, iii„oTownship, Range, Section:T� SrTf� r-1 �f T/ 2. Site Plan Depth Feet �^.onAti�f, 3 1- 2- 3- 4- 5- 6 z ry -3- 4- 6zry 13- 14- 15- 16-1 17- 80'rpe,M 3-14- 15- 16- 17- %3/))OM I,- i/” 0 A10 /Ja O ,A,e Z.-Vocr c WAS GROUND WATER Date ENCOUNTERED? Net Time Depth to Water 8 IF YES, AT WHAT DEPTH? L Depth toWaterABer O Monitoring? F E Date:.`]///(' S Reading Date Gross Time Net Time Depth to Water Net Drop 30 'e / U /y DCD/`M aTn\I D�1C mm"ULt UWMETER _ l r TESTRUNBETWEEN c/ Fr AND l FT COMMENTS PERFORMED BY: CERTIFY THAT THIS TEST WAS PERFORMED IN ACCORDANCE WITH ALL STATE AND�; MUNICIP L GUIDELINES IN EFFECT ON THIS DATE. DATE: S/(//oM�