ON-SITE WASTEWATER DISPOSAL SYSTEM AND/OR WELL INSPECTION REPORT
Permit Number: SW060120 PID Number:
Wastewater System: (] New ❑ Upgrade
Nye'
SPINELL HOMES, INC.
Add,"" 1900 W. NORTHERN LIGHTS BLVD, SUITE 200
ABSORPTION FIELD
Ptaro 344-5676 Numb" of Bedroema 4
to Do" Trach 0 Shall" Trach O Bed t] Mwrtd O o"W
Sot Rahn;
Total DepN Iron ON" emote
LEGAL DESCRIPTION
0.8 GPDn,t"
6 Ft.
B10"`sLa.
nep N" PM tcmm foal ogmal pude
GavddeptbbenoMh PW
THE TABLELANDS
5
3.5 Fl.
4 Ft
Tov * Ranee Saacn'
FM added above orgelal Grade
Gravel Length1+ 79
FI.
FI.
Gravel Wb
Number d Mlsa
DeWtV Dehvsen Ynlea.
Well:VIA ❑ New ❑ Upgrade
S FI.
1
Ft
claxdcaton (P ate. A, B. CT
Taal Depen
Cased a
Taal aeaadm raa
790
P" Mal"ul PVC 30341SHED 40 PVC
N/A
FI.
Ft
Ft'
pale,
Date Dnbd
Slaic water Level
Irnlalbr
PISANO
Data Mtaaad
7/1/06
FI
Tield
Pump se'"
Ca••a H"M Above G,a"d
TANK
GPM
FI.
FL
SEPARATION DISTANCES
0 Septic ❑ Holding 0 S.T.E P. O Other:
To
Septic
Absorption
Litt
I Holding
ubbr/Pnvale
ManuWww
ANCHORAGE TANK
Am cad 1-5,00
From
Tank
Field
Station
Tank
Sewer Line
Melena
NudWar d CanPadmema
wee
NIA
NIA
NIA
NIA
N/A
STEEL
2
LIFT STATION
sd" atet
100' +
100'+
100'+
N/A
a
MIU JUVnM
WL"
10'+
10'+
101+
N/A
1500 "
ANCHORAGETANK
•Poop o^ bed ad
-Pump W oval at
Hpb wader Gam"
S
Found~
S +
10'+
51+
NIA
42 In
36 in
in.
PMAO 8 Mods
ump
Elecea:al napeobaq pedmwd by
Cuda" On"
N/A
N/A
NIA
N/A
Pj>l �/ OS7(R
R•m•Ms
BENCH MARK
Loral"n aM Dewpead.
TOP OFi■IRd ALARAvL nQF
Ataunwd iavad"n.
100 FL
Er�WL+��PaICiJ;
Inspections performed by: NORTHRIM ENG. Dates: 1f1 7/19/06
Or 4, atiQ
2nd 11/10/06
• ••''rfi9�J
,!�'�Q,:'
•::
Development Services Department Approval
* 4gT►+ s:• .
•
Conditional Approval Dale:
i'
••.. .. .-
✓ ,e,,,,,,...•'
�'srC a• Stevan W. Eng •„
f sf a PE 6256
Date: /'
4 >
Reviewed and approved by:
1Rev WW)e'r•�• 14,--, /)
D ✓l//l/l✓
AS—BUILT
MEASUREMENTS
A
B
Tank C.O.
1 45
21
Tank C.O.
2 49.5
29.5
Manhole
50
31
C01/MT
32
18
Foundation
C.O. 29.5
8
CO2
87
94
DESIGN NOTES:
1. Total Depth of Trench is 8'.
Terrain relatively flat.
2. Sewer Service Line minimum 2% slope.
3. Trench is Minimum 10' from Lot Line.
4. Lots Served by Public Water System.
MULEY CIRCLE
5' T & E Easement 0C5
0)
A
rKeyH2
Absorp n Tr nch
Z 10 4 BcIrm
CO
\ � / Horne
EXCAVATE TH
e C❑NS�TRUCTI❑' °
1500 Gallon STEP Tank
A (0 f/a
��f2C \ 00 $ �01
�f Q/
�rL� P3P7z<�
Septic System Construction
Does Not Preclude Adjoining
Lots From Sanitation
Improvements.
NOR THRIM
ENGINEERING
17237 Beor Pow Circle
Eagle River. A100a 99577
907.694. 7028
1' = 40'
THE TABLELANDS S/D AS -BUILT
--- ----- - _-LAYOUT
BLOCK 5, LOT 1 �•
11/8/06 22 6F 3
0
0
L
C5
ai
U
Y
L
C5
H
4I
0
O
L
d
ar
U
L
0
d
L
0
0
lL
L
d
f
u
L
i
0
L-
u
CL
(U CU
s
u
L
i
f-
0
F -
W
(U
co
II
L
O
-P
d
N
W
N
O
x
tA
N
o,
M
Ci
o
Q
r—�
w
�\-i
'—'
LL.
lu
n
pa
+II
Z F—
z
C
U
~
J J
W
U
W
V
J
+S
OL
m L J
L
o
a+
a
O
d
O�mY�
U
>
wo
U
2 J
W L
ON
F— pa
d W
ZW
�a
v
W�
U
f
v
a!
U i; N
U N OI
d > d
0 U S
(7 L
O .� Q
a cl o
n •
WC
U 0 >,
d N +'
F -d
dN. d
yr
a, i iU n.
VN
Q0)
Cl L
d
rQ L_CD
O
C
�d O N 0)at
£
LO<
'"•
-0(4" S N
90 i0
UI y Q
O a, L CL 4.N
Uy iJ O O Ldf
`a L` a)u dU Na)
U {+
yFCD iCoL(3)LF-
0I—
II H
c)
0 dY N
o z I L N 0 3
aj Dc
d vj a a+°� 3 d a, aa-
> y Q cn N to 3 to a
W A ^:ci 64U7,,6
W
(U
co
II
L
O
-P
d
N
W
N
O
x
tA
N
o,
M
Ci
o
Q
9
w
�\-i
'—'
LL.
n
pa
Z F—
z
O
U
~
J J
W
U
W
V
J
W
N
m L J
Q
O
f— Y
O�mY�
U
wo
11
2 J
M
F— pa
3
-i
w
�\-i
'—'
LL.
/
A
O
Z
w
z
::D
pa
U
~
Q
Z
w
U
W
V
U_
W
p I�
�Z
Ua
I W
a° .
R
LLJ
Q
2
L
p
e
O
O�mY�
2
na
ZW
�a
W
SOILS LOG — PERCOLATION TEST
r -
TF, Date Performed: 6/28/06
ENGINEERING
Performed For: Si)inetl Homes
Legal. Description: Lot 1, Block 5
DEPTH
(FEET)
Organic
2
SM
Silty Sand
4
w/Gravet
5
6
7
8
9
10
12
13
14 -
15 -
16 -
17 -
I8 -
19
20
21 - I
Comments:
Slope = -5%
Groundwater? No
Depth
Water Depth
After Monitorina, None
Dater 5/10/06
Percolation Rate 7.5 min./inch Perc Hole Diameter 6'
Test Run Between 4' and 5'
Performed By NorthRim Fng, I —
Performed In Accordance with All
ON THIS DATE. DATE: 6/28/06
NORTHRIM
ENGINEERING
77237 Bear Pow Circle
Fogle River, Alaska 99577 ata
907-694-7028
CERTIFY THAT THIS TEST WAS
State/Municipal Guidelines in Effect
THE TABLELANDS S/D ',LOT 1
--�BLOCK 5
GEOTECHNICAL TH2 'We'
6/28/06 12 of -2
11/14/2006 17:43 9073731694 ALLIED AV ELE`;TRIC PAG_ 01/01
ELECMICAG
_ COJVrmAACTIA/G
November 14, 2006
Attn: Steve
Subject: Lift Station inspection at property stated below.
This letter is to confirm that the lift station(s) at:
• Lot 1, Block S — The Tablelands
FAX: (907) 694-7026
was wired by a licensed Journeyman Electrician in accordance kith the 2002 National
Electric Code requirements.
If you would like any further information, please feel free to call our office at the
numbers listed below.
Thank you.
Sincerely,
ALLIED .ALASKA ELECTRIC, L.L.C.
to L. Brown,
PrmidentlCFO
CC.* file
j NOV I 1_COE
y.
1? Q Nrzb7631�; �ssifla..6daska 1�8T (9R.Ta 3�T1.393 �f t�7J ll:-R�cdt!(S�9?j 323-
384i,�icr
THS IM
ENGINEERING MEMO
Steve Eng, PE, PH
P.O. Box 770724, Eagle River AK 99577
(907) 694-7028 tel
NorthRimEng@aol.com
Date: 12/5/06 Number of Pages: 3
To: Joe Goodall/Jeff Poet
l%IOA On -Site Services
Subject: The Tablelands, B4 L7, B4 L12, & B5 Ll
Comment Sheets
Joe & Jeff,
This is in reply to the three comment sheets. The steepest slope was measured downslope of the
constructed trench & the replacement trench. Analysis was conducted in accordance with the
4/17/04 guidance by James Cross, PE. A profile was drawn with the existing ground slope, the
25% slope line and a line intersecting a point 2.5' above the system extended to the existing
ground at a 35' distance.
The Tablelands, B4 L7: The existing ground dips over 25% at a distance of 15'to 29' from the
replacement trench. The overall slope stays above the 25% line. The slope of the line 2.5' above
the system is @17%.
The Tablelands, B4 L12: The existing ground dips over 25% at a distance of 25' from the
replacement trench. The overall slope dips below the 25% line at a distance of 30' from the
replacement trench. The slope of the line 2.5' above the system is @ 21%.
The Tablelands, B5 Ll: The existing ground dips over 25% at a distance of 22' from the
constructed trench. At this distance a cut -bank is present. This cut -bank requires grading to less
than a 25% slope. Spinell Homes Inc. requests that a conditional approval be granted in order for
the work to be completed next construction season.
Thanks -Steve
Municipality of Anchorage
• Development Services Department
Building Safety Division
On -Site Water and Wastewater Program
4700 South Bragaw St.
P.O. Box 196650 Anchorage, AK 99519-6650
www.ci.anchorage.ak.us
(907)343-7904
ON-SITE SEWER/WELL SUBMITTAL COMMENT SHEET
To: NORTH RIM ENG
Legal description: THE TABLELANDS BLOCK 5 LOT 1
The attached paperwork has been reviewed and is being returned for the following reasons:
❑ Original signature or stamp missing on
❑ Calculation error in design. _
❑ Additional soils information needed. _
❑ Water monitoring results inadequate.
❑ Discrepancy in information submitted.
❑ Topographic information missing or inadequate.
❑ Incomplete; missing
❑ Incomplete; missing _
❑ Additional adequacy test information needed. _
❑ Water sample unacceptable. _
❑ Measured/proposed distances/dimensions missing.
❑ Locations of all soils, percolation and water monitoring tests not shown. _
❑ Proposed system too deep for soils information submitted.
❑ Well log required. _
❑ Omission in narrative.
❑ Insufficient fill over tank or field._
® Other. PRIMARY AND PROPOSED RESERVE TRENCH MAY BE TOO CLOSE TO TOP OF CUT BANK OR
SLOPE GREATER THAN 25%. TRENCH NEEDS TO MAINTAIN 50 FOOT SETBACK FROM SLOPE GREATER THAN 25%.
OR 35 FOOT HORIZONTAL SEPARATION USING INSTRUCTIONS ON ATTACHED MEMO DATED APRIL 7, 2004 AND
WAIVER FEE. PARCEL I.D. AND ELECTRICAL MISSING ON INSPECTION REPORT AND COSA - j eorros,y /
OR,f;414IS
Name of reviewer: JEFF fob Date: November 17, 2006
Please supply the necessary information and re -submit your request.
LEAVE THIS FORM ATTACHED TO THE PAPERWORK
61is/oc Srs1�.. raae59nec( 440114OWd
'FMw
MUNICIPALITY OF ANCHORAGE
Development Services Department
On -Site Water 8 Wastewater Program
4700 South Bragaw Street
P.O. Box 196650, Anchorage, AK 99519-6650
(907) 343-7904
ONSITE WASTEWATER DISPOSAL SYSTEM PERMIT
Initial
Permit Number: SWO60120
Legal Description: THE TABLELANDS BLOCK 5 LOT 1
Design Engineer: 0838 NORTH RIM ENGINEERING
Owner Name: SPINELL HOMES
Owner Address: 1900 W. NORTHERN LIGHTS #200
ANCHORAGE. AK 99517 -
Date Issued: May 31, 2006
Expiration Date: May 31, 2007
Parcel ID: 051-811-59
Site Address: NHN MULEY CIRCLE
Lot Size: 40000 SQ. FT.
Total Bedrooms: 4 Permit Bedrooms: 4
This permit is for the construction of:
0 Disposal Field Q Septic Tank ❑ Holding Tank ❑ Privy ❑ Private Well ❑ Water Storage
All construction must be in accordance with:
1. The attached approved design.
2. All requirements specified in Anchorage Municipal Code Chapters 15.55 and 15.65 and the State of Alaska
Wastewater Disposal Regulations (18AAC72 ) and Drinking Water Regulations ( 18AAC80 ).
3, The engineer must notify DSD at least 2 hours prior to each inspection. Provide notification by calling
(907) 343-7904 ( 24 hours). ( Not required for a Water Supply Permit only).
4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather
must be either: A. Open and closed on the same day.
B. Covered, sealed, and heated to prevent freezing.
5. The following special provisions.
The subsurface disposal field is not within a 30 foot radius of a test hole. The Engineer needs to do an additional test
hole during the construction of the septic field. Please submit stamped and signed results with the As -built Inspection
Report. If the results require a design change, construction of the system will stop pending Onsite review and
approval.
Received By.
Issued By.
Date:
Date: Jr -31-06
Municipality of Anchorage
Development Services Department
Building Safety Division
On -Site Water and Wastewater Program
4700 Bragaw Street
P.O. Box 196650
Anchorage, AK 99519-6650
www.muni.org/onsite
(907)343-7904
ON-SITE SEPTIC/WELL PERMIT APPLICATION
FOR A SINGLE FAMILY DWELLING
Parcell.D. %.5!' Sll59
-
Property owners1-f 0.4f (5,P Day phone 3 42677 5-4"700
Mailing address O c _ /fid�,, 4 Ta fZ00 Zip Code ff 5-/7
Site address
Code ff5e7
Legal description (Sub'd, Block & Lot)3L tG.4�/0 A Lac.% S , /-07—/
Legal description (Township, Section & Range)
Lot Size Ky, 000 Sq. Ft.
THIS APPLICATION IS FOR (®all that apply):
Absorption Field
9
Septic Tank
02
Holding Tank
❑
Privy
❑
Private Well
❑
Water Storage
❑
Number of Bedrooms Y
THIS APPLICATION IS AN:
Initial
Upgrade
❑
Renewal
❑
certify that the above information is correct. I further certify that this application is being made for a
Single Family Dwelling and is in accordance with applicable Municipal Codes.
(Signature of property owner or autVrized agent)
Permit/Rush Fees: Li Gy Waiver Fees:
Date of Payment: �' / _ 0 6 Date of Payment:
Receipt Number: Receipt Number:
(Rev. 11105)
FROM :NortWimEng Engtneering
t.
Y
TH, IR M
FENyCz�INEERING
FAX NO. :907 694-47026
FAX
Jun. 28 2006 08:21PM P1
Steve Eng, PE, PH
17237 Bear Paw Circle, Eagle River AK 99577
(907) 694-7028 tel
(907) 694-7026 fax
NorthRimEng@aol.com
Date: 6/28/06 Number of Pages: 6
To: Deb Wockenfuss 3 i t ,3 -t> - `)
MOA On -Site Services T
Subject: The Tablelands, Block S, Lot 1
REVISED DESIGN
Deb,
We had to revise the design to a STEP system instead of conventional. The house drain was too
low in elevation to use conventional. We will submit good copy.
Thanks -Steve
NQIN 1M_
ENGINEERING
Northitim Engineering
17237 Bear Pow Circle
Eagle River, AK 99577
907.694.7028
May 10, 2006
MOA On -Site Water & Wastewater Program
4700 Bragaw St
Anchorage, AK 99519
RE: Tablelands, Block 5, Lot 1
A lot is being developed. The soil test was good. Groundwater was monitored during the
high water month of May and is not present. A conservative design has been completed,
similar to other lots along this ridge line.
The neighboring lots are mostly developed. This site should not negatively impact any of
the other area lots. The lot slope is relatively flat and drops off in the rear of the lot. A
large greenbelt is present in the back of the lot.
Please review the wastewater system design for the single family home. I have included
design plans & specs, design guidelines, & soil tests. If there is need for additional
information or clarification please give me a call.
Sincerely
Steve Eng, PE, PH5
Design Enclosures
FROM :NortWimEng Engineering
A.
� E l�C, NEERIN"�G
FAX NO. :907 694-47026 Jun. 28 2006 08:21PM P2
The Tablelands S/D, Block 5, Lot 1
SPECIFICATIONS & DESIGN GUIDELINES
Wastewater System Sizing: This is a new 4 -bedroom, single family home. Most of the
neighboring lots are developed. Groundwater was monitored during the high time of the
year was not present. A STEP system is redesigned due to the house elevation. This lot is
over 1 acre in size and no adverse impacts are expected from development. The
neighboring lots are similar. The lots are served by a public water system. No conflicts
to the other lots will take place by this septic system construction. The easements are
located on the drawing and arc not encroached upon. Soil tests revealed silty sandy soil.
An application rate of 0.8 GPD/FT= with 0.5 reduction factor for utilizing a 5' wide
trench. Trench Length - 750 FT=/5'x .5 reduction factor = 75'; 1 line @ 75'. No bedrock
was encountered.
Specification Requirements: All components and work must comply with the Municipality
of Anchorage Specifications (AMC) & State of Alaska Drinking Water Regulations and
Wastewater Regulations.
• Two compartment, 1500 gallon S.T.S.P, tank conforming to Anchorage Tank &
Welding/Orenco Systems Specifications, allowing gravity -flow from outlet.
• Watertight couplings on inlet & outlet
• 5' minimum between the tank and bed. 10' to property lines.
• 2' of cover is required for trench + 1 inch insulation board.
• Tank & solid pipe must be set on well compacted, stable soil
• 4 inch diameter cleanouts with airtight caps are required 1 to 4 feet from foundation wall,
prior to any 90 degree bend in 4 inch line.
• All eleanouts must extend to at least ground level
• Trench to be placed level, minimum of 4' to groundwater, 6' to bedrock from drain -rock
Drain rock to be''/� inch to 2'/i inch screened. Drain rock to be distributed uniformly
throughout the trench.
• Distribution pipe shall be 1.25" Schedule 40 PVC w/ 1/8" orifices @ 27" on center.
• Force main shall be 1.25" Schedule 40 PVC, conforming to Anchorage Tank &
Welding/Orenco Systems specifications. Force main burial to he 4' minimum.
• Silt barrier (filter fabric) to be installed above the drain rock
• Smeared trench sides must be raked or scarified before drain rock placement
• Approved pipe materials Include cast iron, PVC ASTM D3034, PVC ASTM F789. ABS
ASTM D2661, PVC Schedule 40.
• Sewer Service Line is minimum 2% slope
• Septic Tank to be pumped every two years or when required
• Insulation board shall be extruded direct burial polystyrene (Dow Styrofoam M or equal)
• Maintain minimum 10' separation between water line & wastewater system.
FROM :NortWimEng Engineering FAX NO. :907 694-47026 Jun. 28 2606 08:22PM P3
DESIGN NOTES:
1. Total Depth of Trench is 8'.
Terrain relatively flat.
2. Sewer Service Line minimum 2% slope.
3. Trench is Minimum 10' from Lot Line.
4. Lots Served by Public Water System.
MULEY CIRCLE
I E : cnt
1500 Gallon STEP Tank
n
\�
EXCAVATE TW
e C❑NTRIiCTI❑ �No, \ Start of 25% Slope
•°o ' I /Fill WILL Not Impact
A��f2 \oAP 8
c d�
F
��fLF °SP3Ph�
a
o,
i Key
P4 Box
4 Bdrm
Home
Septic System Construction
Does Not Preclude Adjoining
Lots From Sanitation
Improvements.
i--......... _.. ... ........
NOTE, EXISTING S.�
GREATER THAN 25;
TO BE FILLED WIT
50' OF TRENCH
FINAL SLOPE TO B
LESS THAN 25%
Ease
OPE
NOR THRIM 'THE TABLELANDS S/D
ENGINEERING REVISION
177237 Bear Pow Cirele;;,•:: ` ---- 'LAYOUT
. Cagle Rhe. Aloako 99377 �eA
BLOCK 5, LOT 1
907.694.7028 6/28/06 11 of -4
FROM :NortWimEng Engineering
c �
s
V
�W
I
�Z i
�'
O
O
N
s
i
C+
�'
O
� 0
1
L^
-O
�
I
5 p
2
• v o`
n
c�
rl
1 p
o
a
a
m
a
rrl
70
d
m
1--4
m
Z
N t
Mr-=
\ M
1--1
M a
d VI
r- M
o�
a
t=j
i
I
3
m
0
x
R
s
r
o
s
�
C+
�'
••1
� 0
+-4
L^
-O
�
I
5 p
2
n
'wn
$s
3
c
M
�'
••1
N
+-4
L^
S
:
5 p
2
$s
c
Q
1
Yr
V
50
Z7
f
�
0
P
FROM :NorthRirfEng Engineering
!
1
�
V
Y
"
o
q
p
b
225 V
O
U i
V
bo
R
i
w
Z �
N 3
m
�
2.
G
wn
;
a;
�
V O
7 felh
i
FAX NO. :907 694-47026 Jun. 28 2006 08:23PM PS
mcns.w Mt- m
m m p M MM
a^m*O+-D'M Z
�oN��6nSz
m -1-b 7Z03...I fn
hp n h� "s
N0h17M?!p3
'O Q, Vi
n MtnH0O-OCR
F7 p'+ 33 3
od
hto
3 3 O'F
O
33 3 Q
ln9 N� rao
'F In D
0 N Q.
a eo o
3
w
o 0 0
v
m m P
m n
h
9 =-
3
n
v
ry
m
v
Sh
r P
....
fU RI
o
p
O 3
p
U i
9 0
'�°
= O
X
N 3
p
OI
G
;
a;
0
0
7 felh
z` :D
....
fU RI
o
j
� CD
O 3
p
S�3
9 0
'�°
= O
X
N 3
p
N
G
o
0
0
7 felh
z` :D
0
z
A
3
n
S
M
�o
z
FROM :NorthRlmEng Engincerl
C N
eN
G
1
mz i
�
V
im
1
i �S.�a 11•s�;h,
i
i ,
Y.
i p
t N
�y
w -4
r=
om
Lll
n
td
r�
oz
--q ty
d
i
FAX NO. :907 694-47626 Jun. 28 2006 08:23PM P6
-o
C)
0
A
rn
g
M
b
s
3
i.i.wro ty
(.n --4.0
mp n
� 3 fn Z
5' Z— -I p
!3g: 43 m
is cin"
IQM < 3
�3 < 3h
�tr- S
M eM
a¢Mvl
N\p m
p O
�nz
tea..
Q3
N
7nsp
�o h
�D
T7 N
.+ Q
n d
A p
7C' 3
Roo
�n
N � A
n N
S
0
O
N
r
N
�LL S❑ILS LOG - PERCOLATION TEST
�r` I� Date Performed; 5/2/06
E�1�INEERING
Performed For: -Spinet( Homes
Legal Description/ Lot 1, Block 5
DEPTH
(FEET)
Slope = -20%
Groundwater? No
Depth
Water Depth
After Monitoring. None Tinter 9/in/nr;
#
Date
Gross Time
Organic
1 -
Net Drop
'
5/23
0
--
6'
--
2
5/23
30
30 min.
10'
4'
3
SM
3
--
5.5'
Silty Sand
4
-
62
30 min.
9.5'
4'
;: • •:'
w/Gravel
65
--
r.:'.
--
5
-
95
30 min.
9.5'
4'
6
-
7
8
9 -
10-
'•,•N,,,...
11
12
13
14
15 -
16 -
17 -
18 -
19 -
20 -
Slope = -20%
Groundwater? No
Depth
Water Depth
After Monitoring. None Tinter 9/in/nr;
#
Date
Gross Time
Net Time
Depth
Net Drop
1
5/23
0
--
6'
--
2
5/23
30
30 min.
10'
4'
3
5/23
32
--
5.5'
--
4
5/23
62
30 min.
9.5'
4'
5
5/23
65
--
5.5'
--
6
5/23
95
30 min.
9.5'
4'
21 - Percolation Rate 7,5 min./inch Perc Hole Diameter 6'
Test Run Between 3' and 4'
Commentsi_PrP-Conked
Performed By NorthRim Eno. I CERTIFY THAT THIS TEST WAS
Performed in Accordance with All State/Municipal Guidelines in Effect
ON THIS DATE. DATEI 5/23/06
pe�6 OF !iC
if NORTHRIM ; ae THE TABLELANDS S/D
ENGINEERING L ❑ T I
17237 Bear Pow Circle """""" BLOCK 5
.. b.
Epple Rtror, Alas 99377 awe ' ,/
07-694-7028 v' GE❑TECHNICAL T.H. 1 - --
5/23/06 11f 2
Municipality of Anchorage
Development Services Department
• '� Building Safety Division
On -Site Water and Wastewater Program
4700 South Bragaw St.
P.O. Box 196650 Anchorage, AK 99519-6650
www.muni.org/onsite
(907)343-7904
ON-SITE SEWERIWELL SUBMITTAL COMMENT SHEET
To: Steve Eng
Legal description: The Tablelands, Block 5. Lott
The attached paperwork has been reviewed and Is being returned for the following reasons:
❑ Original signature or stamp missing on
® Calculation error in design. Incorrect application rate.
❑ Additional soils information needed. _
❑ Water monitoring results inadequate. _
❑ Discrepancy in information submitted.
❑ Topographic information missing or inadequate.
❑ Incomplete; missing _
❑ Incomplete; missing _
❑ Additional adequacy test information needed.
❑ Water sample unacceptable. _
❑ Measured/proposed distances/dimensions missing. _
❑ Locations of all soils, percolation and water monitoring tests not shown.
❑ Proposed system too deep for soils information submitted.
❑ Well log required.
❑ Omission in narrative.
❑ Insufficient fill over tank or field._
® Other. 1, The whole subsurface disposal -field Is not within a 30 foot radius of a test
hole. Please provide an additional test hole(s) placed accordingly.
2, Engineer needs to do percolation tests that follow the procedure called out in Table 3-8
of the EPA Design Manual, Please submit stamped and signed _results for review,
3. 32% slope found at test hole.
Name of reviewer: Deb Wockenfuss
Date: 05/15/06
Please supply the necessary information and re -submit your request.
LEAVE THIS FORM ATTACHED TO THE PAPERWORK
Municipality of Anchorage
Development Services Department
• +1 Building Safety Division
On -Site Water and Wastewater Program
4700 South Bragaw St.
P.O. Box 196650 Anchorage, AK 9951M650
www.muni.org/onsite
(907)343-7904
ON-SITE SEWER/WELL SUBMITTAL COMMENT SHEET
To: Steve Eng
Legal description: The Tablelands, Block S. Lotl
The attached paperwork has been reviewed and is being returned for the following reasons:
® Original signature or stamp missing on revised sheets.
❑ Calculation error in design.
❑ Additional soils information needed. _
❑ Water monitoring results inadequate.
❑ Discrepancy in information submitted. _
❑ Topographic information missing or inadequate. _
❑ Incomplete; missing
❑ Incomplete; missing
❑ Additional adequacy test information needed.
❑ Water sample unacceptable. _
❑ Measured/proposed distances/dimensions missing.
❑ Locations of all soils, percolation and water monitoring tests not shown.
❑ Proposed system too deep for soils information submitted.
❑ Well log required.
❑ Omission in narrative. _
❑ Insufficient fill over lank or field._
® Other. Please show, by existing and proposed topography,how the fill will affect the
Slope and Drainage Easement
Name of reviewer: Deb Wockenfuss
Date: 05/25/06
Please supply the necessary information and re -submit your request.
LEAVE THIS FORM ATTACHED TO THE PAPERWORK
JU �e�5e�e�
NTF-2�M
EIVGINEER�NG The Tablelands S/D, Block 5, Lot 1
1
SPECIFICATIONS & DESIGN GUIDELINES
Wastewater System Sizing: This is a new 4 -bedroom, single family home. Most of the
neighboring lots are developed. Groundwater was monitored during the high time of the
year was not present. A conventional septic system is designed similar to other designs
along this ridge line. This lot is over 1 acre in size and no adverse impacts are expected
from development. The neighboring lots are similar. The lots are served by a public
water system. No conflicts to the other lots will take place by this septic system
construction. The easements are located on the drawing and are not encroached upon.
Soil tests revealed silty sandy soil. An application rate of 1 GPD/FT2 with 0.5 reduction
factor for utilizing a 5' wide trench. Trench Length = 600 FT'/5'x .5 reduction factor =
60'; 1 line @ 60'. No bedrock was encountered.
Specification Requirements: All components and work must comply with the Municipality
of Anchorage Specifications (AMC) & State of Alaska Drinking Water Regulations and
Wastewater Regulations.
• Two compartment, 1250 gallon septic tank. Watertight couplings on inlet & outlet.
• 5' minimum between the tank and bed. 10' to property lines.
• 3' of cover or insulation is required for trench; an equivalent of I" insulation for each foot
soil cover.
• Tank & solid pipe must be set on well compacted, stable soil.
• 4 inch diameter cleanouts with airtight caps are required 1' to 4' from foundation wall, prior
to any 90 degree bend in 4 inch line, in each tank compartment, and two adjacent opposing
cleanouts between the tank and the absorption field, not more than 10' from the tank
positioned to provide cleanout access towards the tank and towards the absorption field.
• All cleanouts must extend to at least ground level.
• In solid pipe runs, ASTM D-3034 may be used in lieu of cast iron.
• Trench to be placed level, minimum of 4' to groundwater, 6' to bedrock from drain -rock.
• Drain rock to be %= inch to 2 %x inch screened. Drain rock to be distributed uniformly
throughout the trench.
• Perforated pipe to be installed level with perforations down.
• Silt barrier (filter fabric) to be installed above the drain rock.
• Smeared trench sides must be raked or scarified before drain rock placement.
• Backfill over drain rock must not be less than 36".
• The finish grade must be mounded to promote drainage over the trench.
• Insulation must be placed over any pipe installed under driveways or parking areas.
• Approved pipe materials include cast iron, PVC ASTM D3034, PVC ASTM F789, ABS
ASTM D2661,
• Sewer Service Line is minimum 2% slope.
• Septic Tank to be pumped every two years or when required.
• Insulation board to be extruded direct burial polystyrene (Dow Styrofoam FII or equal)
DESIGN NOTES:
1.
Total Depth of Trench
is 8'.
Terrain relatively flat.
2.
Sewer Service Line minimum
2% slope.
3.
Trench is Minimum 10'
from
Lot Line.
4.
Lots Served by Public
Water
System.
MULEY CIRCLE
/
T at E Easementrij
cs
L Key
A Box
1250 Galion Septic --T
Double C.O.'s�
T.H.1 ;
\I Absorption Trench
coo s�
\ 'CP
Q1
Q9 N"
\ P
QS
Septic System Construction
Does Not Preclude Adjoining
Lots From Sanitation
Improvements.
NORTHRIM Tjr
ENGINEERING ' '�9m *•
17257 Bear Paw Circles'
£ogle River. Alaska 99377 a•afw r
907.694.7028 l
4 Bdrm
Home
P� \
Ph l`
K
THE TABLELANDS S/D
BLOCK S, LOT 1
LOT
LAYOUT
V = 40':
ET.— -
of 4
DESIGN NOTES:
1. Total Depth of Trench is 8'.
Terrain relatively flat.
2. Sewer Service Line minimum 2% slope.
3. Trench is Minimum 10' from Lot Line.
4. Lots Served by Public Water System.
MULEY CIRCLE
T&E;a.
1250 Gallon Septic Tank
Double C.O.'s--,-.
-h T.H.1f-
EXCAVATE TH
\\
@ CONST\RUCTI❑
No I`
0
tiftp
��f2C \APBd\
�r Q1
F
��rLF °SP�PhK
Septic System Construction
Does Not Preclude Adjoining
Lots From Sanitation
Improvements.
NORTHRIM
p•:; -1
ENGINEERING
9m
17237 Bear Paw Circle......••'••"
(�\
Eagle Rhes, Alaska 99577
cl
........
907.694.7028
.
L
M
4 Bdrm
Home
r5c'C� ed
Key
Box
N❑TEl EXISTING S OPE
GREATER THAN 25'
TO BE FILLED WIT IN
50' OF TRENCH
FINAL SLOPE TO BE
LESS THAN 25%
I' I'
= 40'
THE TABLELANDS S/D M".
BLOCK 5, LOT 1
E ISI❑N
LAY❑UT
oe1.:
5/23/06 11 of 4
L
d
a
N
A
L
N
ice-'
•--�
N
ZD
I
_a
L
J
iu u
a
O
-1
i''
1
pq Y J
Q
F- Y
Y
U
L
Y o
I�
+�
L
= J
a°O3I
O
a,
W
C
L
Y
C% d
L t- I
N
4_
E
A u(
-O:p
3
E
= W
J
f
� CLI
WL`
o
�
F
W 06
A_
3 N N
Q
N
LO CL
tn
L S fn
O N
d -
30
a0d
i
UI N 3 a
O
.f._ s
L
o
{. S >
O. N :3
Qi
U
41
J
F1 Qi N
> Qi o
S O S C
N cUD
0I
H L 3� 7
Z F E E
cu C
z ,~ Gi
c7 L
H F-
W
F7 .-: (V Cl �r
N
s
3
H
Y
N d
Q1...
au
a o.
N V)
c
3
O
PI
N
N
O
S
QI
o,
J
N 0-
L
d
L
O
4-
i
u a
L a
s
d
L
N
i-1
l..
0
a
in
u I
W IN
IV)
ttoioS
O A
V l h
�2 Ua
OD
ZW (OL o
m
Zw�o
.. ty
A
L
N
ice-'
•--�
C5
ZD
o
Q J
L
J
L7
W
O
-1
i''
1
pq Y J
Q
F- Y
Y
U
u
W O
L
= J
a,
W
O
Y
E
3
E
= W
J
f
Z
WL`
o
�
F
W 06
A_
3 Z
Q
J
LO CL
in
u I
W IN
IV)
ttoioS
O A
V l h
�2 Ua
OD
ZW (OL o
m
Zw�o
.. ty
� L \S❑ILS LOG — PERC❑LATI❑N TEST
Th IM Date Performed: 5/2/06
ENGINEERING
Performed For:Spinell Homes
Legal Description: Lot 1, Block 5
DEPTH
(FEET)
Slope = -20%
,e
T�-
Groundwater? No
Depth
Water Depth
After Monitoring. Nnne nntai 5/in/nA
#
Date
Gross Time
Organic
Depth
Net Drop
1
5/2
0
--
7'
--
3 -
5/2
' ''' "' •`
SM
Silty Sand
a -
0.5'
•:'
w/Gravel
5
--
r.:'.:•
--
5
5/2
8
3 min.
6 -
0.5'
5
5/2
7
--
7.5'
--
8
5/2
13
3 min.
9 -
0.5'
10
ti
13-
".
14 -
15 -
16 -
17 -
18 -
19 -
20 -
Slope = -20%
,e
T�-
Groundwater? No
Depth
Water Depth
After Monitoring. Nnne nntai 5/in/nA
#
Date
Gross Time
Net Time
Depth
Net Drop
1
5/2
0
--
7'
--
2
5/2
3
3 min.
7.5'
0.5'
3
5/2
5
--
7.5'
--
4
5/2
8
3 min.
8'
0.5'
5
5/2
10
--
7.5'
--
6
5/2
13
3 min.
8'
0.5'
21 - Percolation Rate 6 min./inch Perc Hole Diameter 6'
Test Run Between 3' and 4'
Comments -
Performed By NorthRim Fng, I CERTIFY THAT THIS TEST WAS
Performed in Accordance with All State/Municipal Guidelines in Effect
ON THIS DATE. DATES 5/10/06
NOR THRIM* THE TABLELANDS S/D I�
ENGINEERING L❑T 1
77237 Bear Paw Clrcl
BLOCK 5
Ec9le Rimr, Aloska 99577 •'.• ams •:
907-694-7028 s GE❑TECHNICAL T.H. 1 �•-----
--- — -- - - 1------- - - --5/10/06 1 of 2
1 \
L \, SOILS LOG - PERC❑LATI❑N TEST
�F IM Date Performed: 5/2/06
[ IVq NEERING
Performed For: Spinell Homes
Legal Description: Lot 1, Block 5
DEPTH
(FEET)
Slope = -20%
Groundwater? No
Depth
Water Depth
After Monitorino. None Date: 5/10/06
#
Date
Gross Time
Organic
Depth
Net Drop
1
5/23
2SM
--
6'
--
2
5/23
30
30 min.
3 -
4'
< ' ••'' :`
Silty Sand
4 -
--
5.5'
--
4
5/23
;:. •:'
w/Gravel
9.5'
4'
r.:'.
5/23
5
--
5.5'
--
6
5/23
95
30 min.
6 -
4-
7 -
9 -
10
12 -
13 -
14 -
15 -
16 -
17 -
18 -
19 -
20 -
Slope = -20%
Groundwater? No
Depth
Water Depth
After Monitorino. None Date: 5/10/06
#
Date
Gross Time
Net Time
Depth
Net Drop
1
5/23
0
--
6'
--
2
5/23
30
30 min.
10'
4'
3
5/23
32
--
5.5'
--
4
5/23
62
30 min.
9.5'
4'
5
5/23
65
--
5.5'
--
6
5/23
95
30 min.
9.5'
4-
21 - Percolation Rate 7.5 min,/inch Perc Hole Diameter 6'
Test Run Between 3' and 4'
Comments: PrP-SonkPd
Performed By NnrthRim Fng, I CERTIFY THAT THIS TEST WAS
Performed in Accordance with All State/Municipal Guidelines in Effect
ON THIS DATE. DATE: 5/23/06
NOR THRIM * asm: THE TABLELANDS S/D
ENGINEERING •• ......••• •• I LOT 1
77257 Clear Pow Cl Cl ••�q••••••� BLOCK 5
Eagle River, Alaska 99577
907-694-7028 GE❑TECHNICAL T.H. 1 �6: �
— ---- — ---- -- _5/23/06 Il of 2
C
d
a
( l0(5
Y
L
CIF -
CL 6
_a F-
d U
a a
WO
U
L
J2
d
L-
L
ON
L�
C
3
O
m
N
W
O
S
W
W
J
N
CL
a
Qj
N
d
i
p
s
W
N
0
N
cu
lf)
Fo,p-j.�r#I
A
L
C/)
Itis«'.
a
A I --
Uoa
Z O
o
cl
Q° o
J
Lit
W
p
-ry1�
4'
W
N
0
N
cu
lf)
Fo,p-j.�r#I
A
L
C/)
Itis«'.
a
A I --
Uoa
Z O
o
Q J
Q° o
J
Lit
W
p
-ry1�
4'
LO /�
hal Y J
A �
Q
v
F— Y
Y
U
o
W0
L
2 J
a
F- W
N
pg
O
7
= w
U—J
—�
2
Z �
LyJ [::I
0'
F
W o6
A
~ Z
3
Q
J
W
N
0
N
cu
lf)
Fo,p-j.�r#I
Itis«'.
on
n
�
\
Uoa
o H
Q° o
ltl
o < a
a
A �
2W
n P
.- W
er�e W
tNOINENMING_TI=
S
The Tablelands S/D, Block 5, Lot 1
SPF,CIFiCAT10NS & DESIGN GUIDF.LINF,S
Wastewater System Sizing: This is a new 4 -bedroom, single family home. Most of the
neighboring lots are developed. Groundwater was monitored during the high time of the
year was not present. A conventional septic system is designed similar to other designs
along this ridge line. This lot is over 1 acre in size and no adverse impacts are expected
from development. The neighboring lots are similar. The lots are served by a public
water system. No conflicts to the other lots will take place by this septic system
construction. The easements are located on the drawing and are not encroached upon.
Soil tests revealed silty sandy soil. An application rate of 0.8 GPD/FP with 0.5 reduction
factor for utilizing a 5' wide trench. Trench Length = 750 FT2/5'x .5 reduction factor =
75'; 1 line @ 75'. No bedrock was encountered.
Specification Requirements: All components and work must comply with the Municipality
of Anchorage Specifications (AMC) & State of Alaska Drinking Water Regulations and
Wastewater Regulations.
• Two compartment, 1250 gallon septic tank. Watertight couplings on inlet & outlet.
• 5' minimum between the tank and bed. 10' to property lines.
• 3' of cover or insulation is required for trench; an equivalent of 1" insulation for each foot
soil cover.
• Tank & solid pipe must be set on well compacted, stable soil.
• 4 inch diameter cleanouts with airtight caps are required 1' to 4' from foundation wall, prior
to any 90 degree bend in 4 inch line, in each tank compartment, and two adjacent opposing
cleanouts between the tank and the absorption field, not more than 10' from the tank
positioned to provide cleanout access towards the tank and towards the absorption field.
• All cleanouts must extend to at least ground level.
• In solid pipe runs, ASTM D-3034 may be used in lieu of cast iron.
• Trench to be placed level, minimum of 4' to groundwater, 6' to bedrock from drain -rock.
• Drain rock to be %2 inch to 2 %2 inch screened. Drain rock to be distributed uniformly
throughout the trench.
• Perforated pipe to be installed level with perforations down.
• Silt barrier (filter fabric) to be installed above the drain rock.
• Smeared trench sides must be raked or scarified before drain rock placement.
• Backfill over drain rock must not be less than 36".
• The finish grade must be mounded to promote drainage over the trench.
• Insulation must be placed over any pipe installed under driveways or parking areas.
• Approved pipe materials include cast iron, PVC ASTM D3034, PVC ASTM F789, ABS
ASTM D2661,
• Sewer Service Line is minimum 2% slope.
• Septic Tank to be pumped every two years or when required.
0 Insulation board to be extruded direct burial polystyrene (Dow Styrofoam Fll or equal)
bTI��IM
ENGINEERING
S/D, Block 5, Lot
Wastewater System Sizing: This is a new 4 -bedroom, single family home. Most of the
neighboring lots are developed. Groundwater was monitored during the high time of the
year was not present. A conventional septic system is designed similar to other designs
along this ridge line. This lot is over 1 acre in size and no adverse impacts are expected
from development. The neighboring lots are similar. The lots are served by a public
water system. No conflicts to the other lots will take place by this septic system
construction. The easements are located on the drawing and are not encroached upon.
Soil tests revealed silty sandy soil. An application rate of 0.8 GPD/FT2 with 0.5 reduction
factor for utilizing a 5' wide trench. Trench Length I I /` AoV D
75'; 1 line @ 75'. No bedrock was encountere
Specification Requirements: All components and work must comply with the Municipality
of Anchorage Specifications (AMC) & State of Alaska Drinking Water Regulations and
Wastewater Regulations.
• Two compartment, 1250 gallon septic tank. Watertight couplings on inlet & outlet.
• 5' minimum between the tank and bed. 10' to property lines.
• 3' of cover or insulation is required for trench; an equivalent of 1" insulation for each foot
soil cover.
• Tank & solid pipe must be set on well compacted, stable soil.
• 4 inch diameter cleanouts with airtight caps are required V to 4' from foundation wall, prior
to any 90 degree bend in 4 inch line, in each tank compartment, and two adjacent opposing
cleanouts between the tank and the absorption field, not more than 10' from the tank
positioned to provide cleanout access towards the tank and towards the absorption field.
• All cleanouts must extend to at least ground level.
• In solid pipe tuns, ASTM D-3034 may be used in lieu of cast iron.
• Trench to be placed level, minimum of 4' to groundwater, 6' to bedrock from drain -rock.
• Drain rock to be %= inch to 2 %: inch screened. Drain rock to be distributed uniformly
throughout the trench.
• Perforated pipe to be installed level with perforations down.
• Silt barrier (filter fabric) to be installed above the drain rock.
• Smeared trench sides must be raked or scarified before drain rock placement.
• Backfill over drain rock must not be less than 36".
• The finish grade must be mounded to promote drainage over the trench.
• Insulation must be placed over any pipe installed under driveways or parking areas.
• Approved pipe materials include cast iron, PVC ASTM D3034, PVC ASTM F789, ABS
ASTM D2661,
• Sewer Service Line is minimum 2% slope.
• Septic Tank to be pumped every two years or when required.
0 Insulation board to be extruded direct burial polystyrene (Dow Styrofoam Eli or equal)
DESIGN NOTES:
1. Total Depth of Trench is 8'.
Terrain relatively flat.
2. Sewer Service Line minimum 2% slope.
3. Trench is Minimum 10' from Lot Line.
4. Lots Served by Public Water System.
MULEY CIRCLE
a
C'
5'T& R
L Key
ra Box
1250 Gallon Septic Tank
Double C.O.'s�
bsor n rench T.H,1
4 Bdrm
\ \r x IHome
EXCAVATE TH 1
@ CON-
CTIO
\-TRI4\No. I Start of 25% Slope
yrs q' �{ Fill Will Not Impact Drai
A��f2
\0 a,
d
c d�
F
���LF QSP�Ph�
Septic System Construction
Does Not Preclude Adjoining
Lots From Sanitation
Improvements,
EASE
NOTE, EXISTINGS ❑PE
GREATER THAN 25'
TO BE FILLED WITIN
50' OF TRENCH
FINAL SLOPE TO BE
LESS THAN 25%
THE TABLELANDS S/D
BLOCK 5, LOT 1
V=40'�
REVISI❑N
LAYOUT
.:
5/2106 1 of 4
NORTHRIM
* �9m�•••:
ENGINEERING
117237 Bear Paw Circle
Eagle Rier• Alaska 99577
•. a -us t,
907.694.7028
EASE
NOTE, EXISTINGS ❑PE
GREATER THAN 25'
TO BE FILLED WITIN
50' OF TRENCH
FINAL SLOPE TO BE
LESS THAN 25%
THE TABLELANDS S/D
BLOCK 5, LOT 1
V=40'�
REVISI❑N
LAYOUT
.:
5/2106 1 of 4
x
0
cn
u
is
Lay
yn
vr¢
f
N
O
J
o
e
V 00
L ,i
N V
a '�o
J
W
W
Z
W
W
'�
V
O
N
b
C
o �
�
J J
N
W
J
�
L
W
N J
(n
W O
J O
J
P21
m
ZLi
N
.. W
O
(�
u c
E
d
~
J
T
tii r o
� 3
c
o
Z c
h r
to
o
� F
V1 H
J
o
ci ri
-W
CIM
o9
3
15�
Y<c
N
O'D O
L).2 Y
u C
Y LW,
N C
Cy
uzl 6
O
moos
N p-14
x
0
cn
u
is
Lay
yn
vr¢
f
N
O
J
o
e
V 00
L ,i
N V
a '�o
J
W
W
Z
W
W
'�
V
O
N
b
Z
LD
t--1
V)
W
A
Q�
W Z
F— ¢
J
W 0
H ¢
N W
3 ¢
�0
Yr
�2Uw
J J
N
W
J
�
L
W
kD
c
1�
F" Y
U
W O
o
J
P21
X�
ZLi
Z
LD
t--1
V)
W
A
Q�
W Z
F— ¢
J
W 0
H ¢
N W
3 ¢
�0
Yr
�2Uw
�`y
ti
N
O n
4LLJl
(�W
iOri '
O
_
ZLi
.. W
s
U
C
0,
L
F
Y
c
d
F-
u
CL
Q,
N
c
w
w
a
a
w
N
•1�
7
O
C
C5
v
v
Ol
c
N
O
CL
a
a
O
u3 Cl Cl)
0,
F- N
p Y
d
H
L
NF -
O
Z 0UNNL O.' -L
141
O
T ti ;
s—s 3
+• w aN3
0 ••�.{ �^
a o
O OI
C
rLvqlo-
O
;.
CL
i
�S
.2
O
f-
tA
-P
7
�2
p Y
d
CN
NF -
Z 0UNNL O.' -L
141
Nd
p
s—s 3
+• w aN3
a o
O OI
U
rLvqlo-
= d
a"i Qcu
0 c)3w<
Y
�S
0L
4N
U"c
.
v
U
d
N W
a
n.
U
f
N �
u v
+' L N
U N L
d> doq
CL 0 U U U
M rz
o ca
0
U O T
d N t
d to .- C
p, L N Q
U to
4� £L O
O 3 3 3 _
i o £ Y
PQ L d
p O U
a£ y+�
Co (L L in tea, £ u
N— 0).S(4 LO O.
O�LQ �N
U N L J O o L
Celt L� yU+'V N
(00)
A
Z F-
O
J J
W
J
PQ Lo
Q
F- Y
U
W O
2 J
F-- PCI
3 �
W
h-,
i Q
Q �
Z Y
w z
Q
U ~
Z U
W
W
0
•
4-
O
in
M
N
0
N
W
Q
W
F-
V)
U
f--4
F-
COOI
L1J
�I
N U d
L _y 75;
�2
w e
o0,
Z 0UNNL O.' -L
141
o„$
p
s—s 3
+• w aN3
a o
n
a"i Qcu
0 c)3w<
A .4 fU vi 4 ui ,D
Ln
P
.3wo2
m
m 0
gm
r
<
n
.r.�.
:°
p
O
O
.
V
aN P S
N
e
0
!Z F 2 N
\
F
•
3
F
p 0
tclsz
tib'
hQ:3
tn
�rDNC:
1
iii
N m
N
N
a
n�
d
-�'
p P
1
tclt
O
A
200
C+
Ln
n
I i
a
is
__0SIU
U
N
X11 •11•'
h
I O
N
I
N
CJI ..
•�•r•!•r:
1
•� •r.� •}.
I.
Ln
P
v
.3wo2
m
m 0
-0Q
r
<
n
:°
p
O
O
N
V
aN P S
N
e
0
!Z F 2 N
\
F
3
F
p 0
tclsz
hQ:3
tn
�rDNC:
3 Z h
N m
N
N
a
n�
d
-�'
p P
1
tclt
O
A
200
C+
Ln
n
I i
a
is
__0SIU
U
N
h
I O
N
►
N
CJI ..
•�•r•!•r:
1
•� •r.� •}.
I.
tj
K�K�ti
I
v
.3wo2
m
m 0
-0Q
r
<
n
:°
p
O
O
N
V
aN P S
N
e
0
!Z F 2 N
\
F
3
s
3
M
:Aw Nr tl
m
.3wo2
ci
3:3 3C Z
;3n3
.3 33 -1O
C C Z --1
3 c 3 3 m
:c c)n rn
Qt O S
h� iTN
V
aN P S
!Z F 2 N
\
__
P W
io
F
p 0
tclsz
hQ:3
tn
�rDNC:
3 Z h
N m
N
N
a
n�
d
-�'
p P
1
z 7
O
A
200
C+
Ln
n
I i
a
is
__0SIU
U
N
h
I O
N
N
MUNICIPALITY OF ANCHORAGE
OF S
Development Services Department -8 Phone: 907-343-7904
On -Site Water & Wastewater Section Fax: 907-343-7997
Certificate of On -Site Systems Approval
Parcel I.D. 051-811-59
Legal description THE TABLELANDS BLK 5 LT 1
Site address 23316 Muley Cir Chugiak
Expiration Date: Z 3
Current property owner(s) Angeli Mohanani-Posey & Daniel Posey
X The On-site system(s) is/are approved for 4 bedrooms
Conditional approval for bedrooms, with the following stipulations:
Comments or advisories:
0
Original Certificate Date: 4/10/2023
This Certificate of On -Site Systems Approval (COSA) is intended to demonstrate the subject
system(s) is/are in substantial compliance with municipal code. The Municipality of
Anchorage, Development Services Department (DSD) issues COSAs based upon
representations provided by an independent professional engineer. The Municipality of
Anchorage is not responsible for errors or omissions in the professional engineer's work.
ATTACHMENTS:
COSA Checklist X Well Flow Advisory
Absorption Field Advisory Nitrate Advisory
Tank Age Advisory Arsenic Advisory
Other
COSA Approva"une 2022
MUHMPAUTY OF ANCHORAGE
Development Services Departments r� Phone: 907-343-7904
On -Site Water & Wastewater Section Fax: 907-343-7997
Certificate of On -Site Systems Approval Application
1. GENERAL INFORMATION
Parcel I.D. 051-811-59
Complete legal description THE TABLELANDS BLOCK 5, LOT 1
Location (site address) 23316 MULEY CIRCLE, CHUGIAK, AK 99567
Current property owner(s) ANGELI MOHANANI-POSEY& DANIEL POSEY Day phone
2. ON-SITE SYSTEMS SIZED FOR 4 BEDROOMS
3. TYPE OF WATER SUPPLY: ❑ Private Well ❑ Private Well serving 2 dwelling units
❑ Private Well serving 3+ dwelling units ® Community Well or Public
❑ Water Storage
4. TYPE OF WASTEWATER DISPOSAL: ® Private Septic ❑ Private Septic serving 2 dwelling units
❑ Holding Tank ❑ Community Septic or Public Sewer
5. SEPTIC TANK: ® Steel ❑ Plastic ❑ Concrete ❑ Fiberglass
Age 17 - See advisory if steel older than 20 years
6. ABSORPTION FIELD: ❑ AWWTS ❑ Bed ❑ Deep Trench ® Wide Trench ❑ Seepage Pit
Waiver request for:
Expedited review requested: ❑
Distance:
By applying for this entitlement, this property is subject to inspection by municipal On-site staff
to verify the accuracy of the information provided.
COSA Fee $ / 1/ S Waiver Fee $
Date of PaymentJZ -7 Date of Payment
COSA # ac -2G2 -;J077 Waiver#
COSA Application.doc
COSA Checklist.docx
COSA Checklist
Legal Description: THE TABLELANDS BLOCK 5, LOT 1 Parcel ID: 051-811-59
If more than 1 well and/or septic system on lot, provide separate checklist. Structure served by this system ____
A. WELL DATA - PUBLIC &/OR CLASS “A” WATER
Well log is filed with Onsite (or attached)
Date drilled Total depth ft
Cased to ft
Sanitary seal is functioning correctly
Wires are properly protected
Casing height (above ground) in.
Date of flow test for COSA
Static water level at beginning of test ft.
Well production at time of test gpm
Water storage tank volume NA gallons
Well disinfected for coliform test? Yes No
Coliform bacteria is Negative
Nitrate mg/L Nitrate less than MRL (ND)
Arsenic ug/L Arsenic less than MRL (ND)
Collected by
Date
Comments __________________________________________________________________________________
B. TANK DATA
Measured operating fluid level in septic tank *NA
Date of pumping 3/29/23
Required maintenance completed, if AWWTS
Comments: STEP TANK - *FLOATS
C. LIFT STATION
Required maintenance completed
Age of lift station 17 years
Lift station material STEEL
Comments:
D. ABSORPTION FIELD DATA – TESTED BY CURTIS TOWNSEND & TEST DATA NOTED 8/3/3021 <2YRS
Which system tested (date installed) 2006
ALL standpipes present per record drawing
Total measured depth from grade 7.4 ft (max)
Measured depth to pipe invert from grade 4.1 ft (min)
N/A – pressurized field.
Per record drawings, field is insulated.
Monitor tubes go to bottom of effective.
If not, state depth into effective *3.84’ OF 4’ IR ED
Presoaked required if
(Required if house vacant or field not used for more
than 30 days prior to date of test)
Gallons introduced gallons date
Any rejuvenation treatment (past 12 months) N
If yes, enter date
Adequacy test date 8/3/2021
Results Pass
Fluid depth prior to test 26 in
Water added 616 gal
New fluid depth 31 in
Elapsed time 1440 min
Final fluid depth 26 in
Absorption rate 600+ gpd
FIELD STATUS – POST RECOVERY
Effective depth (per record drawings) 48 in
Effective depth used 26 in
Effective depth remaining 22 in
Comments/Deficiencies: *Elevation shots show 3.84’ effective depth (ED) or 0.16’ / 2” ED approximately
missing. Fluid measurements taken on 3/30/2023 show 20” of standing fluid & absorption field apparently
operating in the midpoint of the ED and the top half of the system.
COSA Checklist.docx
E. SEPARATION DISTANCES
From Private Well on Lot to: (Please enter distances if less than required or if community well on lot) - NA
Septic Tank/Lift Station on Lot > 100’
Yes if No ft
Neighboring Tank > 100’ Yes if No ft
Absorption Field on Lot > 100’ Yes if No ft
Neighboring Absorption Fields > 100’
Yes if No ft
Community Sewer Main > 75’ Yes if No ft
Community Sewer Manhole/Cleanout > 100’
Yes if No ft
Private Sewer/Septic Line > 25’ Yes if No ft
Holding Tank > 100’ Yes if No ft
Animal Containment > 50’ Yes if No ft
Manure/Animal Excreta Storage > 100’
Yes if No ft
N/A – Served by Community Well (not on lot) or Public Water
From Septic/Holding Tank and Absorption Field(s) on Lot to: (Please enter distances if less than required)
Building Foundations > 10’ Yes if No ft
Tank to Property Line > 5’ Yes if No ft
Field to Property Line > 10’ Yes if No ft
Water Main > 10’ Yes if No ft
Water Service Line > 10’ Yes if No ft
Surface Water > 100’ Yes if No ft
Wells on Adjacent Lots:
Private Wells > 100’ Yes if No ft
Community Wells > 200’ Yes if No ft
If tank or field is under driveway comment below
F. ENGINEER’S COMMENTS
G. CERTIFICATION & STATEMENT OF INSPECTION BY ENGINEER
As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based
on procedures outlined in the Certificate of On-Site Systems Approval Guidelines, indicates that the on-site water
supply and/or wastewater disposal system appears to comply with applicable Municipal and State codes,
ordinances, and regulations in effect at the time of installation, unless noted otherwise.
Name of Firm FIRST WATER CONSULTING Phone 907-350-9566
Engineer’s Printed Name CURTIS HUFFMAN, PE Date 4/3/2023
Comments: This investigation was completed in compliance with MOA guidelines, regulations,
and best industry practices / methods. The assessment of the condition of the well and septic
applies only to the conditions as of the day tested. The flow and absorption rates may change
due to subsurface conditions that may not be observed from the surface, changes in land use,
local soil characteristics, groundwater levels that may fluctuate during the year, quality of
construction (workmanship & materials), the water usage of the family being served by the
system and maintenance. The operational life of all well and septic systems are subject to
these various and dynamic characteristics and are outside the control of the evaluator of the
well and septic system. Therefore, any or NO estimate of how long a system will function satisfactory
for current or future occupants or guarantee that no unseen encroachments, deficiencies or
discrepancies exist can be given by First Water Consulting &
4/3/2023
MUNICIPALITY CE ANCHORAGE
Development Services Department Phone: 907-343-7904
On -Site Water & Wastewater Section Fax: 907-343-7997
Parcel I.D. 051-811-59
Certificate of On -Site Systems Approval
Expiration Date:
Sl- 3-2ozz
-1.--GENERAL INFORMATION
Complete legal description THE TABLELANDS' BLK 5 LT 1
Location (site address) 23316 Muley Cir Chugiak
Current property owner(s) LANGE MARK & FRANCES
Mailing address
Real estate agent
23316 Muley Cir Chugiak
2. TYPE OF DWELLING:
0 Single Family (w/wo ADU)
❑ Duplex
❑ Multiple Dwellings (Single Family and/or Duplex)
3. NUMBER OF BEDROOMS: 4
AK 99567
Day phone
AK 99567
Day phone
4. TYPE OF WATER SUPPLY: TYPE OF WASTEWATER DISPOSAL:
Private Well ❑ Private Septic Z
Water Storage ❑ Holding Tank ❑
Community Well ❑ Community ❑
Public Water System E Public Sewer ❑
Waiver request for: Distance:
Received by: Date:
COSA to be released to the engineer, unless otherwise requested by the engineer.
COSA Fee $ 55 O Waiver Fee $
Date of Payment g loh-1
Receipt Number oy 73 z D
COSA # D SC 21 1 y ( 40
Date of Payment
Receipt Number
Waiver #
5. STATEMENT OF INSPECTION BY ENGINEER
As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based
on procedures outlined in the Certificate of On -Site Systems Approval Guidelines for this application, shows that the
on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate for the number of
bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the
Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater
disposal system is (are) in compliance with all applicable Municipal and State codes, ordinances, and regulations in
effect at the time of installation. I acknowledge that On -Site staff may visit the site to verify the information submitted.
Name of Firm Eklutna Engineering, LLC
Address 19162 Mountain Rd Chugiak AK 99567
Engineer's Printed Name Curtis Townsend, PE
Phone 907.406.1058
Date D 9
,� OF
AL-IMi—O co
6. DS SIGNATURE
oil
oPP4o• s.•orp
System #1 Approved for L bedrooms��y'; ..
NAS L.'{ • lid
System #2 Approved for bedrooms �� �F�• °�o. E11904�`��'�
Disapproved �'kil 9FROFESSIONP'�
Conditional approval for bedrooms, with the following stipulations:
`g ON-SITE �
K AND m�
m WASTEVv ATER z;
JQ_� PR0GF\AM o�
By: Original Certificate Date: " Z
The Municipality of Anchorage Development Services Division (DSD) issues Certificates of On -Site Systems Approval (COSA) based only upon the
representations given in paragraph 5 by an independent professional civil engineer registered in the State of Alaska. The Municipality of Anchorage is
not responsible for errors or omissions in the professional engineer's work.
7. ATTACHMENTS:
COSA Checklist X Nitrate Advisory
Septic System Advisory Arsenic Advisory
Well Flow Advisory Other
COSA Checklist blue sheet
r
Legal Description: THE TABLELANDS BLK 5 LT 1
If more than 1 septic system on lot: COSA Checklist # of
A. WELL DATA
❑ Well log is filed with Onsite (or attached)
Date drilled
Total depth ft
Cased to ft
❑ Wires are properly protected
Casing height (above ground) In.
Date of flow test for CO
Static water at beginning of test ft.
Ce ments public water
B. TANK DATA
Age of tank(s) 15 years
Tank type/material STEP gCg
Measured operating fluid level in septic tank 48
0 Standpipes/foundation cleanout per record drawing
Date of pumping May 2021
D. ABSORPTION FIELD DATA
Which system tested (date installed) 2006
❑ ALL standpipes present per record drawing
Total measured depth from grade 8.2 ft (max)
Measured depth to pipe invert from grade 4.2 ft (min)
❑ N/A — pressurized field
❑ Monitor tubes go to bottom of effective. If not, state
depth into effective
❑ Code -required soil cover over field
❑ System presoaked
(Required if vacant for greater than 30 days prior to
date of test)
Gallons introduced gallons
Comments/Deficiencies:
COSA Checklist yellow sheet
Parcel ID: 051-811-59
Structure served by this system
Well production at abiform
test M____
Water storage tane gallons
Well disinfected test? ❑ Yes ❑ No
❑ Wiferrm bacteria is Negative
Arsenic ug/L ❑ Arsenic less than MRL (ND)
Collected by
Date of Sample
C. LIFT STATION
❑ Required maintenance completed
Age of lift station 15 years
Lift station material steel
Comments:
Adequacy test date ""2021
Results El Pass For 4 bedrooms
Fluid depth prior to test 26 in
Water added 616 gal
New depth 31 in
Elapsed time 1440 min
Final fluid depth 26 in
Absorption rate ' 600 gpd
Any rejuvenation treatment (past 12 months) no
If yes, enter date
E. SEPARATION DISTANCES
From Private Well on Lot to: (Please enter distances if less than required or if community well)
Septic Tank/Lift Station on Lot > 100'
0
Yes
Community Sewer Manhole/Cleanout > 100'
❑✓ Yes
if No
ft
Q Yes
if No
Neighboring Tank > 100' M Yes
if No
ft
Private Sewer/Septic Line > 25' 7 Yes
if No
Absorption Field on Lot > 100' 0 Yes
if No
ft
Holding Tank > 100' M Yes
if No
Neighboring Absorption Fields > 100'
p✓ Yes if No.
Water Main > 10'
Animal Containment > 50' M Yes
if No
M Yes
if No
ft
Yes if No.
Water Service Line > 10'
0
Yes
if No
Manure/Animal Excreta Storage > 100'
If septic tank is under driveway comment below
Community Sewer Main > 75' ❑✓ Yes
if No
ft
P( Yes
if No
From Septic/Holding Tank on Lot to: (Please enter distances if less than required)
Building Foundations > 10'
0
Yes
if No
ft
Surface Water > 100'
R Yes if No.
Property Line > 5'
✓V
Yes
if No
ft
Wells on Adjacent Lots:
Q
Absorption Field > 5'
if No
Yes
if No
ft
Private Wells > 100'
p✓ Yes if No.
Water Main > 10'
ft
Yes
if No
ft
Community Wells > 200'
Yes if No.
Water Service Line > 10'
0
Yes
if No
ft
If septic tank is under driveway comment below
From Absorption Field on Lot to: (Please enter distances if less than required)
Building Foundation > 10' 1 2✓ Yes if No ft If absorption field is under driveway comment below
Property Line > 10'
0
Yes
if No
ft
Wells on Adjacent Lots:
Water Main > 10'
Q
Yes
if No
ft
Private Wells > 100'
Water Service Line > 10'
Q
Yes
if No
ft
Community Wells > 200'
Surface Water > 100'
0
Yes
if No
ft
F. ENGINEER'S COMMENTS
G. ENGINEER'S CERTIFICATION
I certify that I have determined through field inspections and review
of Municipal records that the above systems are in conformance with
MOA COSA guidelines in effect on this date.
COSA Checklist yellow sheet
qt
b
'49
eana .............
rh L. Tawny d
�pp ��• Cate Tai
S� `n0liJ '. No. CE 11904 ®AV
-h,-10
PROFESSNt� �
ft
ft
ft
ft
ft
ft
ft
ft
�✓ Yes if No ft
❑✓ Yes if No ft
Lift Station/Pump Vault
Maintenance Log
Owner Street Address
Septic Tank:
--veslh�o -Pumping- completed Y�CR71�
c -h -es' '--P, ping: -required
Slu 1, t-)
Lift station: TY_)?_Q � 2- �
-Pump basket cleaned 'T&no -Effluent filter cleaned f - no
Control floats cleanedno
0 Lno -Proper float settings confirmed e
-Operation satisfactory s no
e
Alarm System:
-Dedicated electrical alarm circuit /,_s no -Audible and visual alarm inside dwelling 148 no
-Alarm system operatioC satisffor Lnot satisfactory
Manhole Riser
-Ground water intrusion at riser to tank connectionves (n6\
-Ground water intrusion around pipe penetrations. es -Weep hole functionally`_ no
-Manhole lid: Functional,(?R�no Insulated fes no Properly secured es no
Other
*All manufacturer required inspections and maintenance completed ,yds no
Comments:
Qualified Maintenance Provider:
Technician ,
echnician'��eLA-Y) Date of maintenance
Company MOD t -Se Date
I
Signature
. d
Mumc><pahty of Anchorage ��Zp�
-- Development Services Department *A1
Building Safety Division
On -Site Water and Wastewater Program
4700 Bragaw Street
P.O. Box 196650
Anchorage, AK 99519-6650
www.muni.orglonsite
(907) 343-7904
CERTIFICATE OF ON-SITE SYSTEMS APPROVAL
FOR A SINGLE FAMILY DWELLING
Parcel I.D. 661- 811- Sq COSA#- U00-56-3
Expiration Date: o tt
1. GENERAL INFORMATION
Complete legal description 72f` 7;4ff1r[.*q J S 7$.40 C k S LOT f
Location (site address)
Current Property owners)
Mailing address
Lending agency
Day phone—;?W "7 00._... _ .
Day phone
Mailing address .
Real Estate Agent
Day phone
Mailing Address
Unless otherwise requested, COSA will
be held by DSD for pickup.
2. NUMBER OF BEDROOMS:
3. TYPE OF WATER SUPPLY:
TYPE OF WASTEWATER DISPOSAL:
Individual Well
❑
Individual On-site
Individual Water Storage
❑
Individual Holding Tank
❑
Community Class Well
❑
Community On-site .
❑
Public Water System
P
Public Sewer
❑
The Municipality of Anchorage Development Services Department (DSD) issues Certificates of Onsite Systems
Approval (COSA) based only upon the representations given in paragraph 4 by an Independent professional civil
engineer registered In the State of Alaska. Certificates of On -Site Systems Approval are required for the transfer of
tide (except between spouses) for properties served by a single-family on-site wastewater disposal and/or water
supply system. DSD also Issues COSAs upon request to homeowners. Certificates of Onsite Systems Approval
are valid for 90 days from the date of Issue for properties served by a private or Class C well and may be reissued
with new water sample results. (Certificates may be reissued for a period of up to one year with valid water
samples.) Certificates are valid for one year for properties served by Class A or B wells or a public water system.
The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work.
4. STATEMENT OF INSPECTION BY ENGINEER
As certified by my seal affixed hereto and as of the validation date shown below. I verify that my Investigation,
based on procedures outlined In the Certificate of Onsite Systems Approval Guidelines for this application,
shows that the on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate
for the number of bedrooms and type of structure indicated herein. 1 further verify that based on the information
obtained from the Municipality of Anchorage files and from my investigation and Inspection, the on-site water
supply and/or wastewater disposal system Is(are) In compliance with all applicable Municipal and State codes,
ordinances, and regulations in effect at the time of installation.
Name of Firm A104 Qim E:,1 9.
Address%aff_7 Ria✓ ��.� �✓r-�Qo
Engineer's Printed Name_ FniG
5. DSD SIGNATURE
—11 Approved for to bedrooms.
Disapproved. �7�
Phone (9 W-70e—e
Date //�/��JG
.�y�e Or AC'40r0a
d•�".1 •. ��
��'c'•`�: Steren Y1. Eng �u
ag A, A PE 6256 .` N
•AN
Conditional approval for bedrooms, with the following stipulations:
Attachments:
COSA Checklist X
Septic System Advisory
Well Flow Advisory
Nitrate Advisory
Arsenic Advisory
Maintenance Agreements
Supplemental Engineer's Report
Other
By: Original Certificate Date: 11('
(Rev 11105)
Municipality of Anchorage
Development Services Department
Building Safety Division
On -Site Water & Wastewater Program
4700 Bragaw Street
P.O. Box 196650
Anchorage, AK 99519-66W
www.muni.org/onsite
(907)343-7904
CERTIFICATE OF ON-SITE SYSTEMS APPROVAL CHECKLIST
Legal Description: THF 'T—i413LFL.4�d f RL Ct:P' c LOT/ Parcel ID:
A. WELL DATA
We"
tyje
Date cTotal dft.
Dale of test
Static water level
Well production
WATER SAMPLE
If A, B, or C provide PW D #
Sanitary seal
Cased to ft.
FROM WELL LOG
ft.
Coliform colon' x/100 mL Nitrate mg/L
Arsenic: m Date of sample:_
B. SEPTICIHOLDING TANK DATA
Tank Type/Material STEP T4AIK.
Tank size Sda gal, Number of Compartments Z
Foundation cleanout (YIN)Depression over tank (Y/N) .4L
1t
Date of pumping / - Pumper
C. ABSORPTION FIELD DATA
Date installed 24, o or Soil rating (g.p.d./ft' or ft�/bdrm) Q. 8
Length 7f ft. Width S ft.
Total depth —it ft. Eff. absorption area %per ft:
Date of adequacy test A1ryJ
Well Log (YM)
Wires properly protect (Y/N)
Casing height (abo ground) in.
AT INSPECTION
ft.
g.p.m.
Other bacteri colonies/100 mL
Collected Ify.
Date installed
Cleanouts (Y/N)
High water alarm (Y/N)
Monitoring tube
Results (Pass/Fail)
System type % �j6Ate- f
Gravel below pipe _ ft.
Depression over field Af
For _ bedrooms
Fluid depth in absorption field before test _ in. Water added_ gal. New depth_ in.
Elapsed Time:_ min. Final fluid depth _ in. Absorption rate >= g_p,d,
Any rejuvenation treatment (past 12 mo.) (YIN & type) If yes, give date
D. LIFT STATION
Date installed- Size in gallonsZSQ0 Manhole/Access (YIN)
"Pump on' level atZJ2 in. 'Pump off level at.3C in. High water alarm levet at in.
DatumT�t(K M0TlO6•t t Cycles tested 3 Meets alar s circuit requirements?
E. SEPARATION DISTANCES
SEPARATION DISTANCES FROM WELL ON LOT TO: )>✓BLfC VL1e17-0O3Z
Septic tankAift station on
Absorption field on lot
Public sewer main
Sewer /septic se(vice line
Animal containment areas
On adjacent lots
On adjacent lots
Public sewer
Holding tank
Manure/animal exgfete storage areas
SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK ON LOT TO:
i
Building foundation Property line rf Absorption field 'f
Water main 6 If Water service line / d -e- Surface water /Q 0 It
Wells on adjacent lots - -7'()Q rf'
SEPARATION DISTANCE FROM ABSORPTION FIELD ON LOT TO:
rF
Property line / Q 'r" Building foundation / Q 'r Water main
rrt y rkin ehicte storage
Water Service Zine Q fi Surface water LOQ Driveway, pa g/v r / O -F
r
Curtain drain — Wells on adjacent lots — r
F. COMMENTS
G. ENGINEER'S CERTIFICATION
1 certify that I have determined through field inspections and
review of Municipal records that the above systems are in
conformance with MOA COSA guidelines in effect on this date.
Engineers Printed Name � 7! E✓E L�6ti'
Date
COSA Fee $ �q - � Waiver Fee $ _
Date of Payment 11/1-61/06 Date of Payment
Receipt Number 3$1.051 Receipt Number
(Rev. 11/05)
......sem
Siena Y7. Eng
PE 6256 <>e
2004-25
THE TABLELANDS SUBDIVISION
LOT 1, BLOCK 5
40,000 S.F.
MULEY0 CIRCLE
M
N 90'00'00"E 101.75'
/ w— — JCRAVELDR] --—
/ �•,h� / / /
�1 10 /
O m
NM
\ \
\ \ SEPTIC yysTEy EXISTING
\\ BUILDING
s
s�\\ s(\ \
�0• '. CTS\\ 0'0F�,o `\
1 11=40' \
AS
GASTALDI LAND
SURVEYING, LLC
JEFF A. GASTALDI, R.L.S.
4726 WEST 88TH AVENUE
ANCHORAGE, ALASKA 99502
PHONE 248-5454
GRID I DATE
NW1559 8/18/2006
F.B. JOB N0.
06-11 TLS15
BUILDING DETAIL
SCALE: 1 "=20'
I HEREBY CERTIFY THAT I HAVE SURVEYED THE
PROPERTY DEPICTED ABOVE AND THAT NO
ENCROACHMENTS EXIST EXCEPT AS INDICATED.
IT IS THE RESPONSIBILITY OF THE OWNER TO
DETERMINE THE EXISTENCE OF ANY EASEMENTS.
COVENANTS OR RESTRICTIONS WHICH DO NOT
APPEAR ON THE RECORDED SUBDIVISION PLAT.
UNDER NO CIRCUMSTANCES SHOULD ANY DATA
HEREON BE USED FOR CONSTRUCTION OR FOR
ESTABLISHING BOUNDARY OR FENCE LINES.
ANCHORAGE RECORDING DISTRICT, ALASKA
NOTE: NO CORNERS SET THIS DATE
T. do E. ESWr.
i * 49Iu go -'•9
.*
aeeH Idl : o`
♦o, �•
♦. �' '. LS -6091
a
•��
I. of
�•amuis*
Date: 1/29/07
To: Joe Goodall/Jeff Poet
l%lOA On -Site Services
MEMO
Steve Eng, PE, PH
P.O. Box 770724, Eagle River AK 99577
(907) 694-7028 tel
NorthRimEng@aol.com
Subject: The Tablelands Block 5 Lot 1
Joe,
Number of Pages: 1
Pisano brought in about 40 loads of soil & flattened out the slope to less than 25% within 50 feet
of the septic system trench. Photos below. Please issue COSA.
Thanks -Steve
Municipality of Anchorage
Development Services Department
Building Safety Division
_ Onsite Water and Wastewater Program
4700 South Bragaw St.
P.O. Box 196650 Anchorage, AK 99519-6650
www.ci.anchorage.sk.us
(907)343-7904
ON-SITE SEWER/WELL SUBMITTAL COMMENT SHEET
To: NORTH RIM ENG
Legal description: TABLELANDS BL4 LT7, BL4 LT12 B E�
(REFERENCE: TABLELANDS #1 BL9 LT4 & TABLELANDS BL9 LT3 DATED 1015106, FOR
CONSISTENT ENGINEER ERRORS)
The attached paperwork has been reviewed and is being returned for the following reasons:
® COMMENTS:
-SWING TIE NUMBERS INCORRECT
-PLEASE CHECK CROSS-SECTIONAL ELEVATION NUMBERS AND COMPARE WITH INSPECTION REPORT PAGE?
NOT CORRECT, TOTAL DEPTHS ARE DIFFERENT,
SITE PLAN NEEDS TO BE TO SCALE.
SITE PLAN DOES NOT MATCH SURVEY.
-INSPECTION REPORT SITE PLAN SHOULDN'T BE THE SAME AS PROPOSAL SITE PLAN WITH SWING TIES
PLASTED, UNLESS IT ACCURATELY REFLECTS WHAT WAS INSTALLED.
-NEED TO CHECK ELEVATIONS IN CROSS-SECTIONAL DRAWING. ELEVATIONS INACCURATE?
•TABLELANDS BLOCK 5 LOT 1- NORTH RIM ENG. STATES. THERE IS A CUTBANK OVER 25% AT A DISTANCE OF
22' FROM THE CONSTRUCTED TRENCH, AND THAT THE CUTBANK REQUIRES GRADING LESS THAN 25% SLOPE. A
CONDITIONAL APPROVAL IS REQUESTED ASSUMING THE WORK TO BE COMPLETED IN THE NEXT CONSTRUCTION
SEASON.
-NORTH RIM ENG. NEEDS TO PROVIDE THE DESIGN FOR WORK TO BE COMPLETED IN THE NEXT
-MONEY NEEDS TO BE ESCROWED 1.5 TIMES THE HIGH BID FROM A MINIMUM OF 3 EXCAVATORS TO
CONSTRUCT & FINISH GRADING ACCORDING TO ENGINEERS DESIGN APPROVED BY ONSITE PROGRAM.
Name of reviewer: JOE
Cv✓'1:4t0a0V1 Fre?
Geigy Aa. f,TIr �Owpww7 M^�T +��c�+oWtcl�%
Date: December 11, 2006
Please supply the necessary information and re -submit your request.