Loading...
HomeMy WebLinkAboutBIRCH HILLS ESTATES #1 BLK 1 LT 5Birch Hills Estates #1 Block i Lot 5 #050-081-06 Inspectlon hfB 10 Y_y-1-1 L.doc Municipality of Anchorage On -Site Water and Wastewater Program - (907) 343-7904 Page 1 of 2 ON-SITE WASTEWATER INSPECTION REPORT Permit Number: OSP121142 PID Number: 050-081-06 Dwelling: N Single Family (SF) ❑ Duplex (D) ❑ Multiple (SF and/or D) Project: ❑ New 0 Upgrade Name: Mark & Christine Kelliher ABSORPTION FIELD ❑ Deep Trench ❑ Shallow Trench ❑ Bed ❑ Mound ❑ Other Address 12112 Lugene Lane Phone Number of Bedrooms Soil Rating Total depth from original grade 3 GPD/SF Ft. LEGAL DESCRIPTION Depth to pipe invert from original gradeGravel FL depth beneath pipe Ft. Subdivision Block Lot Birch Hills Estates #1 1 5 Fill added above original grade Ft. Gravel length Ft. Township Range Section Gravel width Ft. Beds: Number of Lines Distance between lines I Ft. SEPARATION DISTANCES To From Septic Tank Absorption Field Lift Station Holding Tank Sewer Line Total absorption area Ftp Number of trenches Dist. between trenches I Ft. well 102.3 N/A N/A N/A 83.9 TANK r.❑ Septic ❑ S.T.E.P. ❑ Holding ❑ Other Manufacturer Anchorage Tank Capacity 1500 Gal. Surface Water100+ N/A N/A N/A Material Number of compartments Lot Line 33.0 N/A N/A N/A NA Steel 2 Foundation 18.6 N/A N/A N/A LIFT STATION Manufacturer Capacity Curtain Drain N/A N/A N/A N/A Gal. Remarks Tank replace only. Pump on level at in. Pump off level at in. High water alar at in. Pump make and model Electrical Inspections performed by " Installer Jr's Septic Pumping PIPEMATERIAL Housetotan Tank to iNS drainfield PVC Drainfield C01MT Inspector Pannone Engineering Services BENCH MARK (Assumed elevation)100 it Inspection 1"6/16/12 dates: 2m a" 4" Location and description Garage FF COMMUNITY DEVELOPMENT DEPARTMENT APPROVAL Engineers Stamp Conditional Approval: Date g �teven ♦i. F�annome -7E /8149 �gGE , 44l��� < Approve Date Inspectlon hfB 10 Y_y-1-1 L.doc A B ¢o z zmo FCO 41.2 16.0 T1 51.4 28.7 10 Do T2 45.1 26.3 fl-ss.z DCO 41.9 24.5 NEW t500g SEPTIC TANK , / 1 q�3 INSTALLED /1500g SEPTIC TANK WITH DCO LOT UNDEVELOPED NO WELLS OR SEPTICS �6^^ -M LOT UNDEVELOPED /NO WELLS OR SEPTICS IN77111111 y =� 3BR HOUSE (E) 4 J v EXISTING COLLAPSED 1000g SEPTIC TANK 1 D 42 ABANDONED PER CODE /`L' pRLF W WSW � �qY NOTES:PANNONE ENG SVC LLC -�oF q V\ Date RECORD DRAWING P.O. BOX 100217 ANCHORAGE, AK 99510 S C� •" ' C \io 9724712 PHONE (907) 272-8218 FAX (907) 272-8211 /�GU�p fy�1 Scale P•I.D. NO BIRCH HILLS ESTATES #1, BLOCK 1, LOT 5 �... .... 050-081-08 MARK & CHRISTINE KELLIHER Steven annane % PERMIT NO. 12112 EUGENE LANE I�+�c • 1 81,• AW osP121142 PLAN EAGLE RIVER, AK 99577 ��p'' p sheet z of 2 On -Site Wastewater Disposal System Permit MUNICIPALITY OF ANCHORAGE Development Services Department On -Site Water & Wastewater Program 4700 Elmore Road, PO Box 196650 Anchorage, AK 99519-6650 Telephone: (907) 343-7904 Permit Number: OSP121142 Tax Code Number: 05008106000 Work Type: Septic Upgrade Permit Effective Dates: June 15, 2012 to June 15, 2013 Design Engineer: PANNONE ENGINEERING SERVICE Subdivision: BIRCH HILLS ESTATES #1 Site Legal Address: BIRCH HILLS ESTATES #1 BLK 1 LT 5 G:0253 6110112- `7 pr/\ Owner/Address: KELLIHER MARK HEINRICH & SOIK CHRISTINE M AKA KELLIHER CHRISTINE 12112 LUGENE LANE EAGLE RIVER AK 995777902 Site Mailing Address: 12112 LUGENE LN, Eagle River Lot Size in Sq Ft: 23086 Total Bedrooms: 3 This permit is for the construction of: N Disposal Field Y Septic Tank N Holding Tank N Privy N Private Well N Water Storage All construction must be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80). 3. The wastewater code requires inspections during the installation. The engineer must notify the Development Services Department at least 2 hours prior to each inspection. Provide notification by calling (907) 343-7904 (24 hours). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must either: A. Open and Close on the same day. B. Covered, sealed, and heated to prevent freezing. +m ct g�.hbn 7'061k11z %�eey�neer contecorrecrr�j. Received Issued By: /yVj _ Date: 6 /Z MUNICIPALITY OF — (ric, �It, Community Development Department Development Services Division On -Site Water & Wastewater Program Mayor Dan Sullivan ON-SITE SEWER/WELL PERMIT APPLICATION FOR A SINGLE FAMILY DWELLING Phone: 907-343-7904 Fax: 907-343-7997 Parcel I.D. Q,O-0461-0& Property owner(s) AAAK 9=C4&167%4M &2--0 Mt R Day phone Mailing address 12117— Lu69.V6" L -.IJ �A L ,_"d 1f4K !"6-77 Site address 12112- LJ6.cdE 4"6 Legal description (Sub'd., Block & Lot) Rjec* HILLS e-tyrArCS 0) .61-1< � 1 � Lo? 5� Legal description (Township, Range & Section) Lot Size�Sq. Ft. Number of Bedrooms -3 THIS APPLICATION IS FOR: THIS APPLICATION IS AN: (M all that apply) Initial ElAbsorption Field ❑ Septic Tank Upgrade Holding Tank ❑ Renewal ❑ Privy ❑ Private Well ❑ RUSH! Water Storage ❑ THIS APPLICATION INCLUDES A VARIANCE / WAIVER REQUEST FOR: I certify that the above information is correct. I further certify that this application is being made for a Single Family Dwelling and is in accordance with applicable Municipal Codes. Permit/Rush Fees: k Zco Date of Payment: 6,/..r�2 Receipt Number: O q/ Ll 1 G Permit No. 0S121 -L 114 L Waiver Fees: Date of Payment: Receipt Number: GABuilding\On Site\FormsUient Forms\Permit App_010411.doc (Rev. 1/11) Pannone Engineering Services LLC Steven R. Pannone, Principal Registered Professional Engineer E-mail: steve@panengak.com June 15, 2012 Municipality of Anchorage RUSH! Development Services Department On -Site Water & Wastewater Program 4700 S. Bragaw Street Anchorage, Alaska 99519 Subject: Birch Hills Estates #1, Block 1, Lot 5 Emergency Septic Tank Replacement Permit Request Ladies and Gentlemen: isao I am writing to request that a permit to install a new j.000 gallon septic tank be issued for this lot. The proposed systems will serve an existing three-bedroom house. Currently the lot is developed. The existing septic system was designed and installed for a three-bedroom house and is operating adequately for three bedrooms. The existing 1000 gallon septic tank has collapsed and is exposing raw sewage to the environment. The existing tank will be abandoned per code. The surrounding lots are served by private wells, and there are no wells within 100 feet of the proposed septic tank. This lot is served by a private well that is over 100 feet from the existing drain field and proposed tank. PES will verify all required separation distances at time of installation. 1. Upgrade Tank Design. a. See Sheet 1 of 1 of the plan set 2. Surface Water: There is no surface water within 100 feet of the proposed system. The proposed systems will maintain at least 100 feet from all surface water and drainage ditches. 3. Topography: Lot 5 slopes from east to west at approximately 2% in the area of the tank replacement. The proposed installation will be located in the central portion of the lot next to the existing septic tank and absorption system. Mailing: P.O. Box 1.0023.7, Anchorage, AK 99510 0217 Physical: 332 1%2 East Manor Ave, Anchorage, AK 99501 Telephone: (907) 272-8218 FAX: (907) 272-8211 Page 2 of 2 The proposed installation will not affect the future development of the surrounding or existing lots. There are no wells or septic systems within 100 feet of the proposed septic location. If you have any questions or concerns, please contact me at 272-8218. Sincerely, Steven R. Pannone, P.E. Owner/Civil Engineer Attachments: Mailing: P.O. Box 100217, Anchorage, AK 99510-0217 Physical: 332 1/2 East Manor Ave, Anchorage, AK 99501 Telephone: (907) 272-8218 FAX: (907) 272-8211 WELL I 6m --A, Al LOT UNDEVELOPED /NO WELLS OR SEPTICS WELL (E) 'IAVC e� FSMr °R 5313R HOUSE (E) � g SEPTIC TANK (P) J ^O /5009 WITH DCO J EXISTING COLLAPSED S 10009 SEPTIC TANK / � 5.0 yt, ABANDON PER CODE —W/ 01 G W WSW F)y9 y LOT UNDEVELOPED NO WELLS OR SEPTICS 4 NOTES: PANNONE ING SVC, LLC ,�e� 2�' Date EMERGENCY TANK REPLACE , 9( ACgs1�+ 3/2/12 P.O. BOX 100217 ANCHORAGE, AK 99510 r PHONE (907) 272-8218 FAX (907) 272-8211 'ow - �- # Scale ... ... .. .. :... P.I.D. NO BIRCH HILLS ESTATES #1, BLOCK 1, LOT 5' ' ,,,,4 oso-oal-as MARK & CHRISTINE KELLIHER even R.Pann, one PERMIT NO. 12112 EUGENE LANE +� , t CE s14 OSPXXXXXX 1 s . zv6tr PLAN EAGLE RIVER, AK 99577 �f1,Z.. `=.. Sheet 1e0F 1 GREI"ER ANCHORAGE AREA 606�JGH aa u/M4 sR�a De artment of ro En vit I Q I't p nmen a ua : y 3330 C Street Anchorage, Alaska 99503 INSPECTION REPORT ON-51TE SEWAGE DISPOSAL SYSTEM NAME IISSOCIArE IS'OWDEM MAILING ADDRESS KcX (101 1=A&LC k,&CR PHONE ��.A LOCATION,`�(4 -4/u.AA LEGAL DESCRIPTION �r S Q(OCK � X45/IZL/l �'t/LL$ EI 46 SEPTIC TANK: ` DISTANCE NUMBER OF FROM WELL MANUFACTURER IY.E )e MATERIAL Tru(. COMPARTMENTS '2 - INSIDE INSIDE LENGTH INSIDE WIDTH LIQUID DEPTH I (QUID CAPACITY /Oa0 GALLONS. SEEPAGE PIT: �� NUMBER OF PITS �. DIAMETER SL� OR WIDTH -r, LENGTH 16/, DEPTH LINING MATERIAL IC& CRIB SIZE: DIAMETER —DEPTH— DISTANCE FROM: WELL p� TOTAL EFFECTIVE BUILDING FOUNDATION2_9) , NEAREST LOT LINE 70 ABSORPTION AREA (WALL AREA) 31 SQ. FT. ADDITIONAL ABSORPTION WELL.: C TYPE 7ILI LLFb CONSTRUCTION SrN�7>��'D DEPTH DISTANCE FROM: BUILDING NEAREST NEAREST SEPTIC SEEPAGE FOUNDATION LOT LINE SEWER LINE TANK—,SYSTEM_ CESSPOOL OTHER SOURCES APPROVED DISAPPROVED REMARKS DISTANCES: INSTALLED BY: J QL.F PIPE MATERIAL: &r JI" cAr LOT SLOPE: REMARKS: Form No. EQ -031 DIAGRAM OF SYSTEM 11/05/1997 10:03 9076941211 S AND S ENGINEERING l n GREATER ANCHORAGE AREA BOROUGH DEPARTMENT OF ENVIRONMENTAL QUALITY 1130"C"STREET ANCHORAGE. ALASKA 99501 TELEPHONE 274-4561 SEWAGE DISPOSAL SYSTEM - APPLICATION AND PERMIT NAME OF APPLICANT /�Gt INSTALLATION LOCATION LEGAL DESCRIPTION 314 INSTALLATION OF: SEPTIC TANK I TYPE AND SIZE OF FACILITY TO BE SERVED FINANCED THROUGH SOIL TEST RESULTS COMPLETION DATE ANTICIPATED ADDRESS S LI PERMIT NO. PHONE NOTEI THIS PERMIT 13 NOT VALID WITHOUT SOIL TEST FINAL INSPECTION: 24 HOUR NOTICE REQUIRED. BACKFILLING OF ANY SYSTEM WITHOUT FINAL INSPECTION BY THE DEPARTMENT OF ENVIRONMENTAL QUALITY AUTHORITY WILL BE SUBJECT TO PROSECUTION. SEPTIC TANK SIZE /Cl<50 TYPE 61 SEEPAGE AREA SIZE MINIMUM DISTANCES. REQUIREMENTS FOUNDATION TO SEPTIC TANK :3::l FOUNDATION TO SEEPAGE PIT `! Y 6 DRAIN FIELD I�SAL / SEPTIC TANK TO SEEPAGE PIT WALL V I SEPTIC TANK �5-- SEEPAGE PIT e` � DRAIN FIELD TO NEAREST LOT LINE. WELL TO SEPTIC TANK �D SEEPAGE PIT DRAIN FIELD ALSO CONSIDER AREA WELLS. WATER MAIN TO SEPTIC TANK SEEPAGE PIT - DRAIN FIELD SEPTIC TANK. SEEPAGE PIT .fav DRAIN FIELD TO RIVER. LAKE. STREAM. CAST IRON INTO AND OUT OF SEPTIC TANK AND INTO CRIB CROSSING GAP OF EXCAVATION S FEET INTO UNDISTURBED SOIL. 4 INCH DIAMETER CAST IRON SIPHON PIPES ON SEPTIC TANK AND SEEPAGE PIT FITTED WITH AIRTIGHT REMOVABLE CAPS. GRAVEL BACKFILL CONFORM TO BOROUGH REGULATIONS REg"DING INSTALLATION. G.A.A.S. OR LICENSED DESIGNER TYPE DIAGRAM OF SYSTEM 1 CERTIFY THAT 1 AM FAMILIAR WITH THE REQUIREMENTS OF GREATER ANCHORAGE AREA BOROUGH ORDINANCE NO. 28.66 AND THAT THE ABOVE DESCRIBED S STEM S IN ACCORDANCE WITH SAID CODE. DATE APPLICANT'S SIGNATURE FORM NO. O -0I O MUNICIPALITY OF ANCHORAGE 4P'tIjjOFANt HU1tA0!DEPARTMENT OF HEALTH &HUMAN SERVICESE�p�OEKYICES DlYlllON Division of Environmental Services E On -Site Services Section OU 221997 P.O. Box 196650 Anchorage, Alaska 99519-6650 343.4744 RECEIVED CERTIFICATE OF HEALTH AUTHORITY APPROVAL FOR A SINGLE FAMILY DWELLING Parcel l.D.# 060 -OSI —O(c HAA# 1. GENERAL INFORMATION 1u2O11oc� lob Complete legal description 5;, Bl; let'lA Nlcts Fs+04L5- SID Uvi_"�l Location (site address or directions)�I LLa L 1 N Fnl F L Anl F Property owner %21� TC"* Day phone(or, 14" 3.49 ' 1 Mailing address P.O- 210011 AX ccl5T;� Lending agency Day phone Mailing add Agent Address Day phone Unless otherwise requested, HAA will be held for pickup. 2. NUMBER OF BEDROOMS: 7H2r_F 3. TYPE OF WATER SUPPLY: Individual well X Community well Public water NOTE: If community well system, provide written confirmation from State ADEC attest Ing to the legality and status of system. 4. TYPE OF WASTEWATER DISPOSAL: Individual on-site X Holding tank Community on-site Public sewer NOTE: If community wastewater system, provide written confirmation from State ADEC attesting to the legality and status of system. 72-0251RH. 11911 Fwl MOA 821 5. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation of this Health Authority Approval application shows that the on-site water supply and/or wastewater disposal system is safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I furtherverify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is in compliance with all Municipal and State codes, ordinances, and regulations in effect on the date of this inspection. S & S ENGINEERING Name of Firm 17034 Earle River i ,,..Road Ne 1204 Phone C `t Y - A °r 7 y Address Eagle River, Alaska 99577 Engineer's signature 6. DHHS SIGNATURE Approved for bedrooms. I a Disapproved. Conditional approval for Date Le / -�k � / K 7 ROBERT C COWAN Q. GE-88ol bedrooms, with the following stipulations: Date !(5 9 The Municipality of Anchorage Department of Health and Human Services (DHHS) Issues Health Authority Approval Certificates based only upon the representations given in paragraph 5 above by an independent professional engineer registered in the State of Alaska. The DHHS does this as a courtesy to purchasers of homes and their lending institutions in order to satisfy certain federal and state requirements. Employees of DHHS do not conduct inspections or analyze data before a certificate is issued. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. 72MQbv.1N11 Beet MOAn1 e Municipality of Anchorage t4jovnurr OF 1hON DEPARTMENT OF HEALTH & HUMAN SERVICES ewvtM"►stl� Environmental Services Division n� 825 L Street, Room 502 • Anchorage, Alaska 99501 • (907) 343 4744'1 2 2 Health Authority Approval Checklist RECEIVED Legal Description: L 5 ; L31 ; ( PC,V+ WILLS EeTATES =iJ VN "r Parcel I.D.: 050 -08 ( - 06 A. WELL DATA Well type & wATE It A, B, or C, attach ADEC letter. ADEC water system number Log presen6N) !:I e -c, Date completed (o i 2.4 Total de 320' Casedto 33'+I ' Cro Bsne' )Z,ri- depth Casing height (above ground) Sanitary sea6N) UfA, Wires properly protectedj9iN) uft� FROM WELL LOG Date of test �3 I Static water level 915, Well production WATER SAMPLE RESULTS: AT INSPECTION 10-10—C)-;1 94/ 9-5, g.p.m. t o4 12 S�d1,� 56-v-4. -Its Coliform Ci Nitrate • 4-41 Other "tjrQIGINEEFJNG 1 Date of sample: La I 1319-4 17034 EaQ a ver a o.204 q Collected by: —1 Le r'r"'( Eagle mar, Alaska 99577 B. SEPTICJHOLDINGTANK DATA (urdrr rvoA Clriwwo no ;rccZo;y V -W' J" iAsvlaWj U?x"k, r"scrs a x'd .or �,dL�pes� Date installed 161311J4 Tank size (000 Number of Compartments 2_ CleanoutsJ&N) v^ Foundation cleanout (Y V� rJ 0 Depression (Y® �Q High water alarm (Y/N) a Date of Pumping 1010.1 Pumper C. ABSORPTION FIELD DATA. [05,d MtLrr;&-(-\ 4rivewa2 - sa r�. ta��L iic+ s apF as jedc cakd 44 4 nC� aln.t., Date installed toI 3i 1-44 Soil rating (g.p.d./it' or fts/bdrn) v /k System type r,Lt r� Length 1 h� Width ¢ r Gravel thickness below pipe (ol Total depth 1 D r Effective absorption area � Monitoring Tube present &N),JL�- Depression over field (Yo Q Date of adequacy test 16 — Results ail) ?ASS For TU 2 i� bedrooms Fluid depth in absorption field before test (in.); I �L Immediately after gal. water added (in.): �i5Y2-, V2 II t Fluid depth 3 I V (ins) Minutes later: mAbsorption rate - O g.p.d. Peroxide treatment (past 12 months) (YM) I"E J pl ,tJ If yes, give date 72-028 (Rev. 3rg8)• D. UFTVTAJION d Date installed Manhole/Access (Y/N) High water alarm level at' _ Cycles tested E. SEPARATION DISTANCES Size in gallons on" level at' SEPARATION DISTANCES FROM WELL ON LOT TO: "Pump Ott" level at' Septic/holding tank on lot q o CW �rr�mi J On -adjacent lots (bU Absorption field on lot l b v ' On adjacent lots 1 o o ' } Public sewer main 16 m+ Public sewer manhole/cleanout o Sewer /septic service line 25 m F Litt station Ip SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK ON LOTTO: Foundation ib" + Property line mo, -1 Absorption field 5 Water maintservice line —Lo ,4- Surface water/drainage It o ' � Wells on adjacent lots icy, } SEPARATION DISTANCE FROM ABSORPTION FIELD ON LOT TO Property line 10a { Building foundation lo' + Water maintservice line 10, + • + - ¥ VN Dr.QI:HttN l�R.w EwM Surface water the Driveway, parking/vehicle storage area S»su 120 w I PaacPe+E � R�SEfcS Curtain drain tID'Ar, Wells on adjacent lots IN) F. ENGINEER'S CERTIFICATION I cerlify that I have determined thru field inspections and review of Municipal in conformance��OAA HIAA gui eAnes in effect on this date. Signature 'r� Engineer's Name /` 0i9 t.47– C_ Co 4,14 � Date m a Z 2L -a-/ 9 7 HAA Fee Date of Pe Receipt Ni 72-028 (Rev. 3/96)' Waiver Fee $ Date of Payment Receipt Number i ROU0 C. cower 1`,,`• CE•8801 It 'Co G.�. `1ew� N LL–L Municipality of Anchorage Department of Health and Human Services 825 "L" Street Rick MyP.O. Box 196650 Anchorage, Alaska 99519-6650 Mayoror . 343-4744 November 5, 1997 Robert C. Cowan, P.E. S S S Engineering 17034 Eagle River Loop Road Suite 204 Eagle River, Alaska 99577 Subject: Waiver Request for Lot 5 Block 1 Birch Bills Estates Unit 1 Waiver Request 9WR970069, PID 9050-081-06, HA970492 Dear Mr. Cowan: Your request for waiver(s) of the required 100 foot horizontal separation of an on—site wastewater disposal system to a private well has been approved. The approved separation distance(s) are the septic tank on lot to the private well onllot of 90 feet. This waiver approval applies to the existing on—site wastewater disposal system to well separation only. Any future upgrade to either will require all separation distances be met or another approval from this department. If there are any further concerns or questions regarding this waiver, please call our office at 343-4744. Sincerely, C olelo Donna C. Mears Civil Engineer On—site Services Program ljm:96 Johnson MUNICIPALITY OF ANCHORAGE Department of Health and Human Services On-site Services Section Waiver Review Worksheet WR# WR970069 PID# 050-081-06 HA# BA970492 Permit # Date Received: October 22, 1997 Legal Description: Lot 5 Block 1 Birch Hills Estate 01 Engineer: Robert C. Cowan P.E., S & S Engineering 17034 Eagle River Loop Road, suite 204, Eagle River, Alaska 99577 Applicant: Eric Johnson Waiver Requested: Septic tank to the well on the referenced property of 90 feet Criteria: 1. Geology: Points: A. Water Table _T6 - B. 6- B. Soil Sorption (• 0 C. Permeability O.9 D. Water Table Gradient (r7• Z E. Horizontal Separation Z (o TOTAL: ( • Z 2. Special Conditions: 3. Other: Waiver is Granted: ✓ Waiver is NOT Granted: List Conditions or Reasons for above: Date: By: E ewer Rec #: 03348/4228 Amount: $ 625.00 Date Paid: Oct 22. 1997 Lot 5, Block 1 Birch Hills Estates Unit #1 Waiver for 90 feet from existing tank to existing well. Issued November 5, 1997 General 1. The septic tank is located at a lower level than the well by 17 feet. 2. The house is located between the well and septic system. 3. The nitrate sample taken from the subject well Is only 0.474 mg/l. WO The well was installed in 1974 at a total depth of 320 feet. The static water level at that time was 215 feet, and is currently 236 feet. The well Is cased to a depth of 33'-4'. Septic Tank The septic tank was also installed in 1974 and is a 1,000 gal, 2 compartment steel tank. It is located under the driveway and is accessed by capped steel risers. The location of the septic tank and disposal field under the driveway has not affected the system's performance In the past 13 years and there Is no Indication of freezing or other problems associated with this placement. ADEC Point Calculations Points Values Water Table 7.5 1-3, B5 Seidler 285 ft. 1-5, B5 Seidler 90 ft. 1-3, B1 Birch Hills Est. Unit #1 195 ft. 1-5, B1 Birch Hills Est. Unit #1 236 ft. Average Water Table 200 ft. Soil Sorption 1 In all well logs bedrock was encountered from very near Permeability 0.9 the surface to the bottom of the wells. Water Table Gradient 6.2 Horizontal Separation 2.6 Total Points 18.2 Elevation of well = 589' Elevation of Tank = 572' Slope = (589'- 572) / 90' = 18.9% 0 As per ADEC waiver guidelines a point value of 18.2 is almost sure to be free of any form of contamination from household sewage. S& KALTHAITHORTTY October 21, 1997 ROBERT C. COWAN, P.E. CMLENGINEERS (907) 6942979 FAX(907)694-1211 APPAMALS MUNICIPALITY OF ANCHORAGE Department of Health and Human Services P.O. Box 196650 SEWER &WATER Anchorage, AK 99519 MAIN DDENSIONS REFERENCE: Lot 5; Block l; Birch Hills Estates #1 SEWER& WATER INSPECTION Request you issue a Health Authority Approval on the referenced property and grant a waiver for the horizontal separation distance between the septic tank and well on the referenced property at 90 feet. The mitigation factors involved which support the END/NEERINGSTUDIES issuance of the waiver are as follows: AND REPORTS 1. The location of the septic tank is at a lower elevation than the well. This would alleviate any surfacing effluent from reaching the well head. The plot plan contained WELL INSPECTION within this report shows the well 16 feet higher in elevation than the septic tank. & ROW TEST 2. The house is located between the well and the septic system which would also alleviate surfacing effluent from reaching the well head. SITE PUNS 3. The nitrate sample taken from the well located on the referenced property indicated .474 mg/1 Y. AI/a Ar 74C Mia Tv 4.IL WSJ PN4r. '•A4ov,.4I,.4 I'G UAS 4fl •r / I.JL.0 AF CHO'1 ROAD DESIGN /^^AE'P ,^4L4, RNR•Gr, Pro r4G rV, C. 44 ri.t PRO/... •.G Nom. r4Av4L( Ar )P If you require additional information, please contact us. Sincerely, SOILTEST '0 7 Robert C. Cowan, P.E. PERCOLATION TEST RCC/gk STRUCTURAL & MECHANICAL INSPECTIONS ONSITE WASTEWATER DISPOSAL SYSTEM DESIGN 17034 NORTH EAGLE RIVER LOOP • SURE 204 • EAGLE RIVER, ALASKA 99577 1" =� 30' f� 2�.I�! 0 oS FIR 0 0 LUCEN �-- s H r � � 0 0 Z SIC 44)V oLDmo \ E V\m0V4 \ o O C y \ Zyee \ n r \Dn0 y C N z v 0 0 N � ter• �� n C O � 00"0y z2VIN ONO 2A 0Z<N NFn aA 1 b 'BOAS IZC fqC MOM Ezm � rt�Or N am o;a O 4 C. s "_ opA O KOOO*ZO V Zm Z mA Vl0=N�W-ZN O..>0= MO.' >0 m SSb Z N H oy= MO .'O A y OX3. oo0 _z O 2 0 O N x _ 44)V oLDmo \ E V\m0V4 \ o O C y \ Zyee \ n r \Dn0 y C N z v 0 0 GREATER ANCHORAGE AREA BOROUGH Department of Environmental Quality 3330 "C" Street, Anchorage, Alaska 99503 274-4561 Date Received 2/3/75 Time of Inspection Date of Inspection 2/3/75 REQUEST FOR APPROVAL OF INDIVIDUAL SEWER & 14ATER FACILITIES FOR 1. Approval requested by: Eric Johnson Mailing Address: MY 1101 Fagte River Phone: 2. Property Owner: Aaanriare Builders Phone: Mailing Address: Engle River b -A 3. Legal Description: Lot S. Block 1 Birch Ilills Teraeee 4. Location: 5. Type of facility to be inspected Single No. of bedrooms 3 6. Well Data: A. Type Drilled B. Depth 310' C. Construction Standard D. Bacterial Analysis 7. Sewage Disposal System: A. Installed 1974 B. Installer Self C. Septic Tank: 1. Size 1000 gals 2. Manufacturer Greer D. Seepage Pit: 1. Absorption Area 360 sq/ft 2. Material Log E. Disposal Field: Total length of lines 8. Distances: A. Well to: Septic tank Absorption area Sewer Lines Nearest lot line Other contamination B. Foundation to septic tank 18.5' Absorption area 29' C. Absorption area to nearest lot line 20' EQ -034 (1/74) Page 1 of two pages n Page 2 of two pages - Re�for Approval of Individual Water Facilities Legal Description Lot 5 Block 1 Birch Hills Terrace Comments Approval for well based on dZth and location_ 10e11 not vimd -it time of request for approval P. re, ,C.f Disapproved Date 2/3/75 Approval,Valid for one year from date signed Greater Anchorage Area Borough, Department of Environmental Quality DIAGRAM OF SYSTEM I certify that the information contained in this request for approval to be a true and accurate representation of the subject sewer and water facilities and these facilities are operating satisfactorily. SIGNED EQ -034 (1/74) Date