HomeMy WebLinkAboutBEAR RIDGE LT 10Bear Ridge Lot 10 #067-621-16 Municipality of Anchorage Development Services Department it Building Safety Division ; On-Site Water 8 Wastewater Program, 4700 Bragaw St. P.O. Box 196650 Anchorage, AK 99519.6650 www.ci.anchorage.ak.us (907) 343-7904 Page 1 of 3 Onsite Wastewater Disposal System and/or Well Inspection Report Permit Number: SW060257 PID Number: 067-621-16 Name: KELLY GRAY Wastewater System: ■ New ❑ Upgrade Address: 562 WEST 19TH AVE a ANCHORAGE, AK 99503 ABSORPTION FIELD Phone: No. of Bedrooms: (907) 230-3910 4 D Deep Trench ■ Shallow Trench O Bed D Llound 0Other LEGAL DESCRIPTION WRwng: 1 2 Tater ow f 8 MAX GPD/Sq. rL In. Black: Lot: Subdivision: Depth to pipe Canso frau arg" grade. Gravel depth beneath pipe: — 10 BEAR RIDGE SEE DWG. r< 4.11 rL Township: Range: Section: M oaded above oNguwl grade: Grmwl lw%gth. — — — SEE DWG. R 50 rL WELL: ■ New ❑ Upgrade Gravel width: 5 IA,ma.r of Isere:D'atanae 1 W~lkwe: — rt r< cia"coation Prhate, AB.0 : Total Depth. Coeed To: Total oa.orption area; Ppb material: PRIVATE 245 244 500 D 3034/ F-810 n n so. ,L Oneer: SULLIVAN WATER WELLS Date Drilled: /17/2007 static waly l.w.N: ARTESIAN Yw1wMr. NORTH COUNTRY Date I wtalled: 5/7-9/2007 T.W:Pup 25 Set At: m199 Cowng Neight AOaove G,: e2 TANK GP„ rl r< SEPARATION DISTANCES 11111 Septic ❑Holding ❑S.T.E.P. 0Other* 7o Septic Absorption Lift Holdingbrw/Pd ate Maadaclwr. GREER TANK Capacity N gwl 1250 ham Tank Field Station Tank sewer ones Well too'+ 100'+ — — 25'+ tataw: STEEL NwnMr a ewnpartmenl.: 2 Surface water 100'+ 100'+ - - - LIFT STATION Lot Line 5'+ 10'+ — _ _ Sue in gwlar: aaadacturer: Foundation 5'+ 10'+ _ _ _ ° on.level at` °° Nigh water Glean at: Curtain Drain NONE KNOWN Pyne Nuke '� Elecukal ktepwtf performed r7 Remarks: a CASING HEIGHT IS AT 2 FEET BUT THERE IS A BENCH MARK loeouon and D..alpum DEPRESSION AROUND WELL. FIXING THE DEPRESSION WILL BOTTOM OF SIDING ®NORTH EAST CORNER RESULT IN LOWERING THE CASING HEIGHT UNDER 2 FEET. BOTH ISSUES WILL BE FIXED IN SPRING OF '08. A.evm Elevouon: 106.05 rt Inspections performed by: GEG, Ltd. Dates: 1st 5/7/2007 ENGINEER'S SEAL 2nd s/s/zoo? 00000 o OF...... 3rd _ •••••.. Development Services Department Approval p'?` I �.......... ............�*.� 1,70 0 0 Conditional approval: Date: 111.4 I Ii O p '•.J r Go ess: A /A f A R nc/ Gcr iF D Q e E- �) Reviewed and approved by: rU Date: FIZ 6 Od d'roressla�°oma (R.v. 4/05) QQ0�D�p0 GARNESS ENGINEERING GROUP, Ltd. CONSULTANTS 3 GENERAL CONTRACTORS May 7, 2009 Municipality of Anchorage Development Service Department On -Site Water & Wastewater Program 4700 South Bragaw Street P.O. Box 196650, Anchorage, Ak 99519-6650 (907)343-7904 Ref: Bear Ridge Subdivision, Lot 10: To whom it may concern: Per our site visit on 5/6/09, the well was found to extend 24 inches above grade and there is no depression 3701 E. Tudor Road, Suite 101 • Anchorage, AK 99507-1259 Ph: (907) 337.6179 • Fax: (907) 338-3246 • Website: www.gamessenginecring.com GARNESS ENGINEERING GROUP, Ltd. I ma CONSULTANTS & GENERAL CONTRACTORS January 18, 2008 Municipality of Anchorage Development Service Department On -Site Water & Wastewater Program 4700 South Bragaw Street P.O. Box 196650, Anchorage, Ak 99519-6650 (907)343-7904 Ref: Drainage Concerns regarding Bear Ridge Subdivision; Lot 10, Mr. Goodall: It is our understanding that you may have some concerns regarding the drainage easement along the south lot line of the referenced property. This drainage easement does have surface run-off during heavy rainfalls and during melt -off periods. However, during our multiple site visits for the inspection of this and neighboring septic systems, and also the inspection of the road, we have not seen any surface water within 100 feet of the septic system. From our observation, the surface water flows from the culvert in the cul-de-sac and runs 50 to 75 feet downhill and then disappears subsurface. Based upon this information, it is our opinion that there are no concerns regarding separation distance from the septic system to surface water. We request the as -built 3701 E. Tudor Road, Suite 101 * Anchorage, AK 99507-1259 Ph: (907) 337-6179 * Fax: (907) 338-3246 * Website: www.garnessengineering.com PERMIT NUMBER: AS—BUILT DRAWING PARCEL ID NUMBER: - SW060257 067-621-16 DRIANFIELD \ bhp / 1 / A 8 ST1 70.55 68.97 ST2 75.17 72.94 DBLl 82.82 80.05 / DBL2 81.54 78.82 C01 118.00 125.93 HE 4 HOUSE\ L 4nnRADIUS e MT1 113.83 81.00 MT2 85.48 120.29 :�NEW DRIANFIELD \ bhp i I I I I i P H NS _ALTERNATE SITE WILL REQUIRE _ AN ADVANCED SYSTEM TREATMENT i / GARNLSS ENGINEERING GROUP, Ltd. - CONSULTANTS 3 GENERAL CONTRACTORS M L nAa RGAA fuII Ib • NK110 ML MFM wwi . Fq[ b 1-Im • »Jl (/07)%Y -]IM • Y092 waysn,�wFyasn i 0 IREPARED FOR: PHONE NUMBER: PAGE NUMBER: KELLY GRAY 230-3910 2 OF 3 4L DESCRIPTION: BEAR RIDGE, LOT 10 OF WORK: AS—BUILT DRAWING 1 K.D.M. �Am i \ / -.00 ey A. arness: C)-7,953 `F`o .l & F8.•.��Ad� / 1 I BEDROOM HE 4 HOUSE\ :�NEW 1250 GALLON SEPTIC TANK i I I I I i P H NS _ALTERNATE SITE WILL REQUIRE _ AN ADVANCED SYSTEM TREATMENT i / GARNLSS ENGINEERING GROUP, Ltd. - CONSULTANTS 3 GENERAL CONTRACTORS M L nAa RGAA fuII Ib • NK110 ML MFM wwi . Fq[ b 1-Im • »Jl (/07)%Y -]IM • Y092 waysn,�wFyasn i 0 IREPARED FOR: PHONE NUMBER: PAGE NUMBER: KELLY GRAY 230-3910 2 OF 3 4L DESCRIPTION: BEAR RIDGE, LOT 10 OF WORK: AS—BUILT DRAWING 1 K.D.M. �Am i \ / -.00 ey A. arness: C)-7,953 `F`o .l & F8.•.��Ad� PERMIT NUMBER: PARCEL ID NUMBER: SW060257 AS -BUILT DRAWING 067-621-16 TOP OF TANK AT INLET = 91.94 STI IFINAL CRADE — 96.21-96.57 ST2 — TOP OF TANK AT OUTLET = 91.82 I I NEW 1000 GALLON I I INVERT OF BUNG SEPTIC TANK INVERT OF BUNG AT INLET = 91.15 AT OUTLET = 90.73 ORIGINAL GRADE = 93.08 GRADE — 93.01-95.47 FABRIC TIVE ELEVATION OF BOTTOM OF TEST HOLE = 76.08 (NO H20) GARNESS ENGINLLRING GROUP, Ltd. 40'r 4 T 7 - CONSULTANTS d GENERAL CONTRACTORS >AI L T.°M LOU, WW 101 • AWIMML M M]0) F1C1[ (I01}U)-�I7r IM (PD)u.IY.VN 09R waysiwr�Yr/YyNn PREPARED FOR: PHONE NUMBER: PAGE NUMBER: ••• •• •••••• .......•••• KELLY GRAY 230-3910 3 OF 31p ee If A. mess. LEGAL DESCRIPTION: DRAWN BY: OQn J Y. CE— 11 53 BEAR RIDGE) LOT 10 K.D.M. OO �e�e ''1 V g•' TWE OF WORK: DATE: 400dProfesslo°°oo AS—BUILT PROFILE 12/11/2007 �40�0000 (R. 01005) C��rtf f teb' �rir�it�g �,.Dg by Doc co. dba SULLIVAN WATER WELLS P.O. BOX 670272, CHUCIAK, ALASKA 99567 -TELEPHONE 698-2759 /OWNER OF LAND: k Y tS % 4r Y ADDRESS: LEGAL DESCRIPTION:—!3C/fC kg. -7— JG DATE: %Off— , PERMIT NUMBER: 1X-Oz2T'� Date of Issue -1--126 TAX IDENTIFICATION NUMBER: OYi -7 _16 Is well located at approved permit location? fifes O No Method of Drilling: 4C�Ifffrotary O cable tool Depth of well: -c1`,,4 Casing Type o L Wall Thickness , aS*Z inches Diameter 16 inches, depth- a feet Liner Type: _- N 1•0s , Casing Stickup Above Ground: _r 2 feet Static Water Level: % l"Ip l & feet Recover Rate: 025- gpm Method of Testing: !91& Well Intake Opening Type:n end O open hole O Screened; Start feet Stopped feet O Perforations Stan feet opped feet a'e�P3e Grout Type: Air T� ^1►T�z o ume Depth: from D feet, to -WO4 feet Well Disinfected Upon Completion? 4k3rrs O No Method of Comments: ' C.r".S,.y& S:,4cKJP j M -4-9j ,e aF.j S'A"y i ctBrlia 17 9fowP4' ^j .< ce8r3cSJ S/YIt�✓ 4�I.r�rFC. ���� Tip N i S`!� ; r 66c �'✓�c S'!t iY j6A,4-Zt 44AY .4 64if J1sc- T/6r-!T Tli.: J 614j� �,-L S4, ro &4:ry 1 Gk�;grA Drifter's Name _ CO L E S c{ Iit an �j_ ATTENTION: It is the responsibility of the property owner to submit a copy of the well log to the proper authority. Municipality of Anchorage: Department of Health & Human Services and/or Department of Environmental Conservation. MatSu Borough. ■ Department of Envlronmental Conservation. 0■ r r ■ r � r � r �■ Tone, 3DVd N"AI-IYIS 6SZZ889 rE:TT LeeZ/eT/ZT ---- ... ARCTIC PUMP & WELL INC. �J1 Jim Sullivan r� PO Box 770197 �In U11 mn6 Eagle River, AK 99577 mii�oma - (907)688-2510 �' t• (907)258.2510 (907)745-2510 91M r-11 Zd2q Pump Installation Log Well Drilling Permit Number: SW060257 Parcel Identification Number: Date of lssue:8-11-06 Legal Description:Bear Ridge Property Owner Name & Address: Lot:10 Kelly Grey Block: 562 W 19'h ave e.,�ti er<oosm Pump Installation Date:5-23-07 Pump Intake Depth Below Top of Well Casing: 199 Feet Pump Manufacturer's Name: Dempster Pump Model:II-75-150 Pump Size: 1.5 hp Pitless Adapter Burial Depth: 10 feet Pitless Adapter Manufacturer's Name Baker Pitless Adapter Installer: Arctic Pump & Well, Inc. Well Disinfected Upon Completion? Yes Method of Disinfection: Chlorine Comments: Pump Installer Name: Arctic Pump & Well, Inc. Arctic Pump & Well, Inc. Page I of I 01/04/2008 16:24 7532530 r /Z/L 17 ASBUILT I HEP.EBY CERTIFY THAT I HAVE SURVEYED THE FOLLOWING DESCRIBED PROPERTY! AND THAT NO ENCROICCHMENTS EXIST D(CEPT AS OoicATED. IT IS THE RSPONSIBILITY OF WNER TO DETERMINE THE DOSTENCE OF ANYE EASEMENTS, COVENANTS, OR RESTRICTIONS WHICH DO NOT APPEAR ON THE RECORDED SUBDI- VISION PLAT. UNDER NO CIRCUMSTANCES SHOULD ANY DATA HEREON BE USED FOR CONSTRUCTION OFFENCE LINES, OR FOR ESTABLISHING BOUND- ARY LINES. W N h J SRWARD & ASSOCIATES LARD SURQEYING 6_ 4-0E SCALE/may 36� Aata,R' DATE, .OF GRID, 4' .......' Fffi t ���/e - o7�y`A DRAWN f-- MUNICIPALITY OF ANCHORAGE Development Services Department 07D On -Site Water 8 Wastewater Program�j\\�/k \ b0 0 4700 South Bragaw Street O P.O. Box 196650, Anchorage, AK 99519-6650 3 7904 ON-SITE WASTEWATER DISPOSAL SYSTEM / WATER SUPPLY PERMIT\ Initial Date Issued: Aug 11, 2006 Expiration Date: Aug 11, 2007 Permit Number: SWO60257 Parcel ID: 067-621-16 Legal Description: BEAR RIDGE LOT 10 Design Engineer: 0855 GARNESS ENGINEERING GROUF Site Address: 3344 BEAR RIDGE CIRCLE Owner Name: KELLY GRAY Lot Size: 42253 SO. FT. Owner Address: 562 WEST 19TH AVE Total Bedrooms: 4 Permit Bedrooms: 4 ANCHORAGE. A 99503 - This permit is for the construction of: M Disposal Field 0 Septic Tank ❑ Holding Tank ❑ Privy ❑✓ Private Well ❑ Water Storage All construction must be in accordance with: 1 The attached approved design. 2. All requirements specified in Anchorage Municipal Code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72 ) and Drinking Water Regulations (18AAC80 ). 3. The engineer must notify DSD at least 2 hours prior to each inspection. Provide notification by calling (907)343-7904( 24 hours). ( Not required for a Water Supply Permit only). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must be either: A. Open and closed on the same day. B. Covered, sealed, and heated to prevent freezing. Date: Y WY 0 Received By: Issued By: _1140�5 Date: Offj�N Municipality of Anchorage • Development Services Department Building Safety Division On -Site Water& Wastewater Program 4700 Bragaw St. P.O. Box 196650 Anchorage, AK 99519.6650 www.ci.anchorage.ak.us (907) 343-7904 ON—SITE SEWER/WELL PERMIT APPLICATION FOR A SINGLE FAMILY DWELLING p�4•'•. �44•i Parcel I.D. 047-621-16 Property owner(s) KELLY GRAY Day phone 230-3910 Mailing address WEST RIa�i1�C•P.[il:d�iC�kl•�•I\ RIDGE9-ite address 3344 BEAR Code 99577 '-eQal descrintion fSub'd, Block & Lot), BEAR RIDGE SURDIMSION, LOT J�L_ '.ega description gownship, Section & Range) N/A Lot Size 92,253 Sq.Ft. THIS APPLICATION IS FOR ( ®all that apply): Absorption Field Septic Tank ED Holding Tank ❑ Privy ❑ Private Well Water Storage ❑ Number of Bedrooms 4 THIS APPLICATION IS AN: Initial Upgrade ❑ Renewal ❑ I certify that the above information is correct. I further certify that this application is being made for a Single Family Dwelling and is in accordance with applicable Municipal codes. GARNESS ENGINEERING GROUP, Ltd. i Permit/Rush Fees: `/G 0 4 1 7_5 Waiver Fees:_ Date of Payment: R/ C(/O ( Date of Payment: Receipt Number. —7 -1 5 3 Receipt Number., (Rev. 11/05) GARNESS ENGINEERING GROUP, W. CONSULTANTS & GENERAL CONTRACTORS August 4, 2006 Municipality of Anchorage Development Service Department On -Site Water & Wastewater Program 4700 South Bragaw Street P.O. Box 196650, Anchorage, Ak 99519-6650 (907) 343-7904 Ref: Proposed Septic Upgrade for Bear Ridge Subdivision; Lot 10, To whom it may concern: The proposed 4 bedroom house will be served by a private well and septic system. We are proposing to install a new 1250 gallon septic tank and a 5 -wide trench type drainfield. One test hole was excavated on the property. The drainfield will be designed around the 30 foot radius of this test hole. Comments regarding the design are summarized as follows: 1. SOILS: See the attached logs which shows the soil classifications, groundwater monitoring, I and the percolation test result. As can be seen on the attached soil log the pecolation rate was <1 minute inch. The soil was classified as a GP -GM material, based upon our visual assessment the insitu silty, sandy soils should act as a sand filter. 2. DRAINFIELD DESIGN: See attached design drawing for drainfield specifications. 3. SURFACE WATERS: There is a drainage ditch that runs along the south lot line. A site visit was made on 8/4/06 and the ditch was found to be dry and have no evidence of water running through it. The septic system is to be installed 100+ feet from any surface water. 1 4. TOPOGRAPHY: As can be seen on the attached design drawing the average topography below the dminfield is a 1-5 percent slope running approximately northeast to southwest. In short, there are no slope concerns. We are unaware of any adverse impacts this installation would have on adjacent wells or septic systems. you have any questQns, please contact us at 337-6179. Thank you for your assistance. 1 M.S. If NOTE: Attached is a site plan drawing, a design drawing, one soil log, which are all part of the design package for this septic system. (Contact G.E.G. Ltd. for 7 page construction specification letter.) 3701 E. Tudor Road, Suite 101 • Anchorage, AK 99507-1259 Ph: (907) 337-6179' Fax: (907) 338-3246' Website: www.gamessenginecring.com EXISTING PROPOSED SEPTIC SYSTEM (SEE DESIGN PAGE 2 OF 2) Pa /I IF LL U / I LOT 12 i LOT 11 /�-r _-`\ 1 100' WELL RADI r PROPOSED I 4 HOUSE / LOT 9 I 1 GARNESS ENGINEERING GROUP, Ltd. CONSULTANTS i GENERAL CONTRACTORS • • • • • .oc e:ooc goo, F/R 10, . wiaoklo - w eo3oi . F10.S Mn In . FM (W)3M-32" • eosin, w PREPARED FOR: PHONE NUMBER: PAGE NUMBER: ••••• KELLY GRAY 230-39' 1 OF 2 LEGAL DESCRIPTION: DRAWN 8: oOOwO, BEAR RIDGE SUBDIVISION; LOT 10 8.F.M. �Q TWE OF WORK: DATE' 0� SITE PLAN FOR PROPOSED WELL AND SEPTIC SYSTEM 8/4/2006 (R.. OIMS) I i � � 1 PROPOSED 100' _I W LL ID I / LOT NUMBER OF BEDROOMS:4 GALLONS PER DAY (GPD): 600 PERCOLATION RATE/S: <1 MIN./INCH PROPOSED APPLICATION RATE: 1.2 MINIMUM DPNNFlELD SO.FT.: 500 IM DEPTH:8 FEET S FEET 1:50 FEET APPROVED SAND FILTER:N/A NE:4 FEET RON FACTOR:N/A . SO.FT.: 500 LETTER THAT PERTAINS TO THIS DESIGN. TO OBTAIN A COPY OF THE LETTER CONTACT CEG. BY PROCEEDING FORWARD WITH THIS INSTALLATION, THE ENGINEER, WELL DRILLER, CONTRACTOR AND PROPERTY OWNER AGREE THAT THEY HAVE READ THESE SPECIFICATIONS AND AGREE TO ACCEPT THE TERMS AND INSTALL FOUNDATION CLEANOUT --, NOTE: THE CONTRACTOR SHALL HAVE THE SOUTH AND WEST LOT LINE FLAGGED BY A REGISTERED LAND SURVEYOR PRIOR TO CONSTRUCTION. ALTERNATE SITE N PROPOSED �DRRAJNNFlELD \ \ \ CAL V/ NEW 4 BEDROOM HOUSE 100' WELL RADIUSI ....................., • '.• .�. .1,• i 4.l / I •may � pDRpOFOpOµ`'�NOU`�E \ j BE DOSED 1250 \/ I SEPTIC TANK / \ / !♦/y / 5 \ `INSTAIl DOUBLE \ I CLEANOUTS / \ GARNESS ENGINEERING GROUP, Ltd. CONSULTANTS & GENERAL CONTRACTORS Q• • • • • • • 1 L TDM IOW. l 101 • ^4000RfL M 0 7 • NOK (907)SA-01n • rM (001)138-M" • �U511[ w�.rwnr•MjivKy�w O PREPARED FOR: PHONE NUMBER: E NUMBER: KELLY GRAY 230-3910 PAC2 OF 2 (LEGAL DESCRIPTION: BEAR RIDGE SUBDIVISION. LOT 10 B.F.M. OF WORK: DESIGN FOR PROPOSED WELL AND SEPTIC SYSTEM 8/4/2006 �s,'001 'ey �y0rn ess.- CE -7953 IlIcc FFG GARNESS ENGINEERING GROUP, Ltd. CONSULTANTS & GENERAL CONTRACTORS SOIL LOG — PERCOLATION TEST LEGAL DESCRIPTION: LOT 10; BEAR RIDGE SUBDIVISION PERFORMED FOR: JOE CIZEK DI DEPTH ____ ORGANICS (feet) TEST HOLE 1 t 'w 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 GP—GM DEPTH TO GROUNDWATER DATE DRY 5/30/2003 DRY 6/12/2003 DRY 8/4/2006 \� I lo 11191 rZZ01 /.% NNE • 0-0. 111111111 SCALE: S0{{' - )� `f71lli Y/f/� • DEPTH TO GROUNDWATER DATE DRY 5/30/2003 DRY 6/12/2003 DRY 8/4/2006 \� DATE IREADING I CT MEK I (MINUTES) NET TIME I W RTEAD ER NG LEVELI NET DROP (INCHES) \N 19 PERCOLATION RATE <1 (MIN./INCH) PERC. HOLE DIA. 6 (INCHES) TEST RUN BETWEEN 3.5 FT. AND 4.0 FT. 20 A FOUR HOUR PRESOAK WAS PERFORMED: ❑ YES ® NO SOILS LOGGED BY: JODY MAUS PERCOLATION TEST PERFORMED BY: JOE MARCHETTI COMMENTS: THE INSITU SILTY SANDY SOILS SHOULD ACT AS A SAND FILTER, PERFORMED BY GEG, Ltd. I, JEFFREY A. GARNESS, CERTIFY THAT THIS WAS IPEJRFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE: 06 I / I / 4T1-111 t I \\ V \� I lo �TH#10 SCALE: I � t' -too' DATE IREADING I CT MEK I (MINUTES) NET TIME I W RTEAD ER NG LEVELI NET DROP (INCHES) \N 19 PERCOLATION RATE <1 (MIN./INCH) PERC. HOLE DIA. 6 (INCHES) TEST RUN BETWEEN 3.5 FT. AND 4.0 FT. 20 A FOUR HOUR PRESOAK WAS PERFORMED: ❑ YES ® NO SOILS LOGGED BY: JODY MAUS PERCOLATION TEST PERFORMED BY: JOE MARCHETTI COMMENTS: THE INSITU SILTY SANDY SOILS SHOULD ACT AS A SAND FILTER, PERFORMED BY GEG, Ltd. I, JEFFREY A. GARNESS, CERTIFY THAT THIS WAS IPEJRFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE: 06 I Municipality of Anchorage a, N On-Site Water & Wastewater Program =(907) 343-7904 CERTIFICATE OF ON-SITE SYSTEMS APPROVAL Parcel LD, 067-621-16 Expiration Date: ( (— 13 1. GENERAL INFORMATION Complete legal description BEAR RIDGE 5/D; LOT 10 Location (site address) 3344 BEAR RIDGE CIRCLE, EAGLE RIVER, AK, 99577 Current Property owner(s) KELLY GRAY Day phone Mailing address Real Estate Agent 3344 BEAR RIDGE CIRCLE, EAGLE RIVER, AK, 99577 PEGGY FRENCH W/ DYNAMIC 2. TYPE OF DWELLING: 0 Single Family (w/wo ADU) ❑ Duplex ❑ Multiple Dwellings (Single Family and/or Duplex) 3. NUMBER OF BEDROOMS: 4 4. TYPE OF WATER SUPPLY: Day phone 230-3910 865-4700 TYPE OF WASTEWATER DISPOSAL: Individual Well 0 Individual On-site 0 Individual Water Storage ❑ Individual Holding tank ❑ Community Class Well ❑ Community On-site ❑ Public Water System ❑ Public Sewer ❑ Received by: Date: L' E"L' COSA to be released to the engineer, unless otherwise requested by the engineer. COSA Fee $ ,-A �t — Date of Payment (mak Receipt Number LII COSA # CSC l3\ a Waiver Fee $ Date of Paymen Receipt Number Waiver # 5. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, i verify that my investigation, based on procedures outlined in the Certificate of On -Site Systems Approval Guidelines for this application, shows that the on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate for the number of bedrooms and type of structure indicated herein. 1 further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation. Name of Firm GARNESS ENGINEERING GROUP, Ltd. Address 3701 E. TUDOR ROAD, SUITE 101 * ANCHORAGE, AK, 99507 Engineer's Printed Name JEFFREY A. GARNESS, P.E. Engineer's Comments: In conducting this evaluation, GEG, LN). attempted to provide a thorough, conscientious engineering analysis of the system in accordance with ADEC and MOA DSD Guidelines B Regulations. The reported results described the performance of the system under the conditions encountered at the time of the test, and separation distances measured to readily identifiable features. The op amtiona/ life of all walls and septic systems depend on the local soils condition, groundwater levels that may fluctuate during the year, and the water usage of the family being served by the system. These conditions are outside the control of the evaluator of the system. Satisfactory test results do not guarantee future performance of the system, nor do they guarantee that there are no hidden defects or encroachments. GEG, LTD. can therefore not provide any warranty or future estimate of how long the system will continue to meet the operational requirements of the ADEC or MOA DSD. The content of this report is for the sole benefit of the owner listed above. Any reliance upon or use of this report by any other person or party is not authorized, nor will it confer any legal right whatsoever. 6. DS'IG D SIGNATURE System #1 Approved for bedrooms. System #2 Approved for Disapproved. Conditional approval for By: bedrooms. bedrooms, with the following Phone 337-61779 Date .. .. .......... ........ P e f y . Go r ess., CE -7953 O'� � . jj ij J y •' . c¢G �n e„ ''La).!'f:.}�•' coo Q4ed pr o f es sl000a ��OO�ood� ,kvv.:SY tOF An;' Original Certificate Date: ON-SITE WATER AND WASTEWATER PROGRAM r)nl 6 -v2/ -f The Mbmicipdrt#%o horage Develop,emt Services Division (DSD) issues Certificates of On -Site Systems Approval (COSA) based only upon the represenatations given in paragraph 5 by an independent professional civil engineer registered in the State of Alaska. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. 7. ATTCHMENTS: COSA Checklist Nitrate Advisory Septic System Advisory Arsenic Advisory Well Flow Advisory Other (Rev. 11/05) If more than 1 septic system is on the lot: COSA Checklist # of_ Structure served by this system Certificate of On -Site Systems Approval Checklist Legal Description: BEAR RIDGE S/D; LOT 10 ParcellD: 067-621-16 A. WELL DATA *ACTUAL PRODUCTION RATE IS LIKELY HIGHER. EXACT WELL PRODUCTION UNABLE TO BE VERIFIED DUE TO PACKER OBSTRUCTING DRAWDOWN MEASURMENTS. Well type PRIVATE If A, B, or C provide PWSID# N/A Well Log (Y/N) YES Date completed 5/17/2007 Sanitary seal (Y/N) YES Total depth 245 ft. Cased to 244 ft. FROM WELL LOG Date of test 5/17/2007 Static water level ARTESIAN ft. Well production 25 — 9 -p.m -WATER SAMPLE RESULTS: Coliform 0 colonies/100 ml Arsenic: / A y Jyug./L. B. SEPTIC/HOLDING TANK DATA NitrateCL j ing./L. Wires properly protected (YIN) YES Casing height (above ground) 24+ in. AT INSPECTION 6/4/2013 SURFACE ft, *2.4+ g.p.m. 695 GALLONS PUMPED FROM THE WELL IN 135 MINUTES Date of sample: 6/4/2013 Collected by: GEG, Ltd. Tank Type/Material SEPTIC/STEEL Date installed 5/7-9/2007 Tank size 1250 gal. Number of Compartments 2 Cleanouts (Y/N) YES Foundation cleanout (Y/N) YES Depression over tank (YIN) NO High water alarm (YIN) N/A Date of pumping 6/3/2013 Pumper JR'S PUMPING C. ABSORPTION FIELD DATA Date installed 5/7-9/2007 Soil rating (.p.d./ r Obdrm) 1-2 Length 50 ft. Width 5 ft. System type TRENCH Gravel below pipe 4.11 ft. Total depth *8.5 ft. Eff. absorption area 500 ft2 Monitoring tube YES Depression over field NO Date of adequacy test 6/4/2013 Results (Pass/Fail) PASS For 4 bedrooms Fluid depth in absorption field before test DRY in. Water added 695+ gal. New depth DRY in. Elapsed Time: min. Final fluid depth DRY in. Absorption rate >= 600+ g.p,d. Any rejuvenation treatment (past 12 mo.) (Y/N & type) NONE KNOWN If yes, give date — D. LIFT STATION Date installed Size in gallons Manhole/Access "Pump on" level at in. "Pump off' level at wa er alarm level Cycles tested - Meets alarm & circuit requirements? E. SEPARATION DISTANCES SEPARATION DISTANCES FROM WELL ON LOT TO Septic tank/lift station on lot 100'+ On adjacent lots 100'+ Absorption field on lot 100'+ On adjacent lots 100'+ Public sewer main Sewer /septic service line 25'+ Public sewer manhole/cleanout N/A Holding tank Animal containment areas 50'+ Manure/animal excrete storage areas 100'+ SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK ON LOT TO: Building foundation 5'+ Property line 5'+ Absorption field 5'+ Water main N/A Water service line 10'+ Surface water 100'+ Wells on adjacent lots 100'+ SEPARATION DISTANCE FROM ABSORPTION FIELD ON LOT TO: Property line 10'+ Building foundation 10'+ Water main N/A Water service line 10'+ Surface water 100'+ Driveway, parking/vehicle storage 10'+ Curtain drain NONE KNOWN Wells on adjacent lots 100'+ F. COMMENTS G. ENGINEER'S CERTIFICATION I certify that i have determined through field inspections and review of Municipal records that the above systems are in conformance with MOA COSA guidelines in effect on this date. Engineer's Printed Name JEFFREY A. GARNESS Date /ig-lb (Rev. 11105)