Loading...
HomeMy WebLinkAboutTERRACE HEIGHTS BLK 1 LT 19, 20Terrgce Height Block I Lot 19&20 #017-074-60 U. M UTA Municipality of Anchorage FEB 0 6 2020 On -Site Water and Wastewater Section • (907) 343-7904 Page of ON-SITE WASTEWATER INSPECTION REPORT Permit Number: OSP191336 PID Number: 017-074-60 Dwelling: ® Single Family (SF) ❑ with ADU ❑ Duplex (D) ❑ Two Single Family Project: ❑ New ® Upgrade Name STEPHANIE ILLANES ABSORPTION FIELD - EXISTING ❑ Deep Trench ❑ Wide Trench ❑ Bed ❑ Mound Site Address 7800 UPPER DE ARMOUN RD. ANCH., AK 99516 ❑ Other Phone Number of Bedrooms Soil Rating Total depth from original grade 4 GPD/SF Ft. LEGAL DESCRIPTION Depth to pipe invert from original grade Ft. Gravel depth beneath pipe Ft. Subdivision Block Lot Fill added above original grade Ft. Gravel length Ft. TERRACE HEIGHTS 1 19,20 Township Range Section Gravel width Ft. Beds: Number of Lines Distance between lines Ft. SEPARATION DISTANCES To Septic Absorption Lift Station Holding Sewer Total absorption area Number of trenches Dist. between trenches From Tank Field Tank Line Ft2 Ft. Well 100'+ -- 25'+ TANK ® Septic ❑ S.T.E.P. ❑ Holding ❑ Other Manufacturer ANCHORAGE TANK Capacity 1500 Gal. Surface Water 100'+ -- Material 10 GA. STEEL Number of compartments 2 Lot Line 10'+ -- NA Foundation 10'+ __ LIFT STATION Manufacturer Capacity Gal. Remarks Existing septic tank removed / decommissioned per code installed, new tank installed in same hole & Alarm location Electrical installed by 5'+ to existing field. Epoxy coated ST. Installer NORTHERN EXCAVATION Tank to PIPE MATERIAL House to tank 3034 dra of eld 3034 Drainfield CO/MT 3034. Inspector FWCS BENCH MARK (Assumed elevation) 100 ft Inspection �' 8/16/19 11 /13/19 Location and description 2nd 3'd 4`h BOTTOM OF TRIM ON-SITE WATER AND WASTEWATER SECTION APPROVAL Conditional Approval: Date 111 - = ' *: 49 TH r .. .. .....�..I` Septic System Approved- A QI/�tJ�-i r •••• ••••..... / Curtis Huffman li Date o� .2��� Note: this approval does not include well permit requirements. p ' ' ' ' ' • ,l ROFEMQp�-.. kmuv uDiu/i 1 D/ TERRACE HEIGHTS BLOCK 1, LOTS 19 & 20 ASPHALT WALKWA A -C=56.5' B -C=23.8' A -D=60.8' B -D=31.2' A -E=62,0' B -E=33.1' A -F=62.8' B -F=34,3' 'L4.v y I � __4 o_ 0o s� CO ;a A D o mo rn z w �rn 93 o 28-C DECK 2.6'x6.3' CANT DFCO FCO PID: 017-074-60 PERMIT: OSP191336 INSTALLED NEW 1500 -GAL SEPTIC TANK PER CODE. O O N D r� MH CO E MH N o 500 CA LS e s O e O MH p PH CD 0 EXISTING MOUND V) MH f Cor CO CO � i,50EPo� ON I 93 59 1500 ST GA I EXISTING FIELD COATED STEEL TANK L.S. SEPTIC SECTION LOT SCALEi 1' = 30 SCALE, NTS PREPARED FOR: SUPPORT®SERVICES: STEPHANIE ILLANES��� OF A' �� TERRACE HEIGHTS BLOCK 1, LOTS 19 & 20 Fe. �`� V7 7800 UPPER DEARMOUN RD, ANCH., AK 99516 10 9TH FIRST WATER CONSULTING DATE: 02/5/2020 rtis Huffman wx "I CE 128991 6p13030 SUES WAY DRAWN: FWCS 2/5/2020 Af ANCHORAGE, AK 99516 '�?orzssio-t0dv 907.350.9566 firstwaterAK@gmaii.com SCALE: 1" = 30' Sl4/q MUNICIPALITY OF ANCHORAGE N On-Site Water&Wastewater Program o�, " ', ,a.e1 PO Box 196650 4700 Elmore Road Anchorage,Alaska 99519-6650 Phone:(907)343-7904 Fax:(907)343-7997 http://www.muni.org/onsite \\ -/ / Department On-Site Wastewater Disposal System Permit Permit Number: OSP191336 Effective Date: 8/8/2019 • Work Type: SepticTank Upgrade Expiration Date: 8/7/2020 Tax Code Number: 01707460000 Site Legal Address: TERRACE HEIGHTS BLK 1 LT 19, 20 G:2940 Site Mailing Address: 7800 UPPER DE ARMOUN RD, Anchorage Owner: ILLANES STEPHANIE Lot Size in Sq Ft: 40744 Design Engineer: ANDERSON CONSTRUCTION & ENGINEERING Total Bedrooms: 4 This permit is for the construction of: ❑ Disposal Field Q Septic Tank 0 Holding Tank 0 Privy 0 Private Well 0 Water Storage All construction shall be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72)and Drinking Water Regulations (18AAC80) 3. The wastewater code requires inspections during the installation.The engineer shall notify the Development Services Department per AMC 15.65. Provide notification by calling (907)343-7904 (24/7). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather shall be either: a. Opened and Closed on the same day, or b. Covered, sealed, and heated to prevent freezing 8/8/19 Received By: Date: �y Issued By: ---/W C/(/. Date: 7/ .lI E,POKT MUNICIPALITY OF ANCHORAGE Development Services Department %1 Phone: 907-343-7904 On-Site Water & Wastewater Section Fax: 907-343-7997 ON-SITE SEPTIC/WELL PERMIT APPLICATION Parcel I.D. 017-074-60 Property owner(s) STEPHANIE ILLANES Day phone 9095781381 Mailing address 7800 UPPER DE ARMOUN ROAD, ANCHORAGE, AK 99516 Site address 7800 UPPER DE ARMOUN ROAD, ANCHORAGE, AK 99516 Legal description (Sub'd., Block & Lot) TERRACE HEIGHTS B1 , LOTS 19 & 20 Legal description (Township, Range & Section) Lot Size 40,744 Sq. Ft. Number of Bedrooms 4 APPLICATION IS FOR: APPLICATION IS AN: TYPE OF DWELLING: (®all that apply) Absorption Field n Initial LJ Single Family (SF) (w/wo ADU) Septic Tank ® Upgrade ® Duplex (D) ❑ Holding Tank Renewal L— Multiple Dwellings ❑ Privy ❑ (SF and/or D) Private Well Water Storage THIS APPLICATION INCLUDES A WAIVER REQUEST FOR: Distance: I certify that the above information is correct. I further certify that this is in accordance with applicable Municipal Codes. FWCS - Brent Western (Signature of property owner or authorized agent) Permit/Rush Fees: Waiver Fees: Date of Payment: B/5119 Date of Payment: Receipt Number: ( $OJgJ) Receipt Number: Permit No. 6$P`Q/,3(7, Waiver No. G:\Development Services\Building Safety\On Site Water and Wastewater\Forms\Client Forms\Permit Application.doc Municipality of Anchorage On-site Water and Wastewater • , P.E. REVIEWED FOR CODE COMPUAN( Michael N. Anderson OSP191336.Deb IMxkenfuss.0840f Civil/Structural Engineering and Construction 4661 Natrona Ave.Anchorage, Alaska 99516 Phone 345-3377 /Fax 345-1391 August 3, 2019 • • Municipalities of Anchorage On-Site Water&Wastewater Program • 4700 Elmore Road Anchorage, AK 99507 RE: SEPTIC TANK UPGRADE PERMIT LEGAL: TERRACE HEIGHTS BLOCK 1, LOTS 19 & 20 To whom it may concern: The owner has requested we proceed forward to obtain a septic permit to upgrade the damaged septic tank on the subject lot. The tank has already been removed and MOA issued a stop work order on the property so we are requesting an expedited, emergency septic tank permit at this time. The proposed upgrade will serve the existing 4-bedroom house. The lot and adjacent lots are served by private wells. The proposed design will not impact any of the neighboring properties due to the lot layout. Please contact Brent M.Western or me if you have any questions. Sincerely, "4400/44c, Michael N. Anderson, P.E. • Support Services Brent M.Western 907-440-4601 Munidpality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMFUAN( OSP191336.Deb Wockenfus; 08/Ot DESIGN CRITERIA: DECOMMISSION EXISTING SEPTIC TANK & INSTALL NEW 1500 GAL. 10GA STEEL S.T. MAINTAIN 10'+ FROM FOUNDATION, 5'+ TO FIELD & 100' TO WELL WITH 4' OF COVER OR INSULATION. o, 24.0' o o �O� o ASPHALT WALKWAlik O cIN �L _X 4.0' 2'x16' CANT tI` N) m o 10.3'x24' DECK <r ` v rn Z Z(7 m OtP 2'x11.6' CANT r — � 4.2' 28.0' L----- STAKE WELL RADIUS 0 O DECK ��� PRIOR TO CONST. O N O N 1 2.6'x6.3' CANT COs rn N N MH CO W INSTALL NEW 1501-GAL • ©MH o SEPTIC TANK PER CODE. 0 O • •• 0 CO • • MH LC O (T)M H O 5 • O O 0 Z (n • •• SEPTIC • VENT (typ) O O (Ni r (N LOT 20 o LOT 19 20,371 s.f. co 20,371 s.f. /— 10' UTIUT' PREPARED FOR: SUPPORT3SERVICES: 41110:111116: 1116`\ OF AL \) STEPHANIE ILLANES i '9 TERRACE HEIGHTS BLOCK 1 , LOTS 19 & 20 FkCS ,62 ,,,- �1, 1- 7800 UPPER DEARMOUN RD, ANCH., AK 99516 .�3 �� �* 49TH " * ,0 Off440/I1/44--# Michael N. Anderson, P.E. DATE: 8/3/2019QMICHAELNoCE N. ANDERSON / �1 9469 � < . `� DRAWN: 4661 Natrona Ave. FWCS F,�,Q 8/3/2019 c r Anchorage, Alaska 99516 1\ pEsslolok`' i (907)727 8864/FAX: (907)345 1391 SCALE: 1" = 30' \\_`4111P. OM :Alpine Drilling FAX NO. :907 345 0202 Sep.26 2011 08:30PM P1 Alpine Drilling & Enterprises Well Log Permit Number: #S'WOSP111220 Date of Issue: &31-11 Parcel Identiifiication Number: 01707460000 Date Started: 9-10-11 Date Completed: 9-11-11 Is well located at approved permit location? x Yea 0 No Legal Description: Terrace Heights Block 1 Lot 19, 20 Property Owner Name & Address: Sean T. Lincoln PO Box 112464 Anchorage, Alaska 995116- 2464 Borehole Data: Soil Type, Thickness & Water Strata Depth (ft) From To Method of Drilling x air rotary ❑ cable tool Casing type: steel Stick-up 0 2 Wall Thickness:.250 inches silt 2 5 Diameter: 6 inches Depth: 221 feet gravelly silt 5 33 Liner Type: Diameter: inches Depth: feet silty cohhly gravel 33 97 Casing stickup above round: 21 feet gravelly silt 97 115 Static water level (from ground level): 154 feet silt 115 137 Pumping level: 221 feet after water .sand &gravel 4gpm 137 141 hours pumping 1 gpm Recovery 1<tute- 4 gpm gravelly silt 191 167 Method of Testing: a li silty gravel 167 198 Well Intake Opening Type: gravelly sandy silt 198 219 x Open End ❑ Open Hole silty water sand & gravel 219 221 ❑ Screened Start feet Stopped feet ❑ Perforations Start feet Stopped feet Grout Type: bentonite granules Volume: 2 bQs Depth: Start 0 feet Stopped ? feet Pump: Intake Depth feet Pump size hp Brand Name Well Disinfected Upon Completion? x Yes ❑ No ®— WATER QUALITY TESTING Method of Disinfection: chlorine tablets COiilaDlTYt v Col/100nnL Nit tes :7 3 nVLAMON Comments: C rJ ug ``i i `I 10 I1 Well Driller: Alpine Drilling & Enterprises PO Box 110496 Anchorage AK 99511 Mark Begich Mayor Development Services Department Building Safety Division On-Site Water & Wastewater P~ogr~m 4700 Elmore Road P.O. Box 196650 Anchomge, A K 99507 www. muni.o~q/o nsj?e (907) 343-7904 Pump Installation Log Well Drilling Permit Number: Date of Issue: Parcel Identification Number: Legal Description Pump Installation Date: ~//'~~0// Pump Intake Depth Below Top of Well Casing: o~0~/feet Pump Size Pitless Adapter Burial Depth: I (~) feet Sep, 28 2011 09:21AH Pi IIProperty Owner Name & Address: I A-gA' ,_Ar, ~16 , INticss Adapter Manufacturer's Name: Pitless Adapter.,,.,. lu,tailer:~/~n Well Disinfected Upon Completion? ~ Yes [] No Method of Disinfection:~f, Cornmeal: Attention: The pump installer shall provide a pump installation log to the DSD within 30 days of pump installation. Page I of I FZPT�—NIIMI From: Sonja Blewett [Sonja@garnessengineering.com] Sent: Thursday, March 28, 2013 1:11 PM To: Poet, Jeff W. Subject: FW: 7800 Upper Dearmoun Road Here is the email from Dave. Thanks! Sonja From: David Harper [mailto:dlharper2@gmail.com] Sent: Thursday, September 22, 2011 10:33 PM To: Sonja Blewett Subject: Re: 7800 Upper Dearmoun Road Sonja, the original well at the above address, which was loeated in the road easement, has been decommissioned as per DEC and MOA requirements. We will send the pump log and Well log via fax. David L. Harper Aarow Pump & Well Service LLC On Thu, Sep 22, 2011 at 2:38 PM, Sonja Blewett <Soni a_ac ,,garnessengineering.com> wrote: Hi Dave. When you are complete with the work on 7800 upper Dearmoun, we will need a copy of the pump log, well log, and a letter from you stating that the other well has been abandoned. Thanks so much! Sonja Blewett Corporate Secretary/Treasurer Garness Engineering Group, Ltd. 3701 E. Tudor Road, Suite 101 Anchorage, AK 99507 Phone: (907) 337-6179 Fax: (907) 338-3246 3/28/2013 Permit Number: Tax Code Number: Work Type: On-Site Water System Permit OSPl11220 O17O74600OO Well MUNICIPALITY OF ANCHORAGE Development Services Department On-Site Water & Wastewater Program 4700 Elmore Road, PO Box 196650 Anchorage, AK 99519-6650 Telephone: (907) 343-7904 Upgrade Permit Effective Dates: August 31, 2011 Design Engineer: GARNESS ENGINEERING GROUP LTD Subdivision: TERRACE HEIGHTS Site Legal Address: TERRACE HEIGHTS BLK 1 LT 19, 20 Owner/Address: LINCOLN SEAN T PO BOX 112464 ANCHORAGE AK 995112464 to August30,2012 G:2940 Site Mailing Address: 7820 Upper De Armoun RD, Anchorage Lot Size in Sq Ft: 40744 Total Bedrooms: 4 This permit is for the construction of: N Disposal Field N Septic Tank N Holding Tank N Privy Y Private Well N Water Storage All construction must be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80). 3. The wastewater code requires inspections during the installation. The engineer must notify the Development Services Department at least 2 hours prior to each inspection. Provide notification by calling (907) 343-7904 (24 hours). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must either: A. Open and Close on the same day. B. Covered, sealed, and heated to prevent freezing. Special Provisions: Prior to final approval, the existing well is to be decommissioned MUNICIPALITY OF ANCHORAGE Community Development Department Development Services On-Site Water & Wastewater Program Phone: 907-343-7904 Fax: 907- 343-7997 Mayor Dan Sullivan On-Site Sewer/Well Permit Application For A Single Family Dwelling Property owner(s) SEAN LINCOLN Mailing address 7800 UPPER DEARMOUN ROAD *ANCHORAGE, AK Day phone 748-9463 Site address 7800 UPPER DEARMOUN ROAD *ANCHORAGE, AK Legal description (Sub'd, Block & Lot) TERRACE HTS; BLOCK 1, LOT 19 & 20 Legal description (Township, Section & Range) Lot Size Sq. Ft. Number of Bedrooms 4 THIS APPLICATION IS FOR: ( [] all that apply) Absorption Field [] Septic Tank [] Holding Tank [] Privy [] Private Well [] Water Storage [] THIS APPLICATION IS AN: Initial [] Upgrade [] Renewal [] THIS APPLICATION INCLUDES A VARIANCE/WAIVER REQUEST FOR: N/A I certify that the above information is correct. I further certify that this application is being made for a Single Family Dwelling and is in accordance with applicable Municipal codes. GARNESS ENGINEERING GROUP, Ltd. (Signature of property owner or authorized agent) /i~' Permjt/-Rush Fees: Date of Payment: Receipt Number: Permit No. Waiver Fees: Date of Payment: Receipt Number: Waiver No. (Rev. 01/11) GAR. NESS ENGINEERING :GROUP, Ltd. CONSULTANTS & GENERAL CONTRACTORS, ~::~::; :: August 12, 2011 Municipality of Anchorage Development Service Department On-Site Water & Wastewater Program 4700 Bragaw Street P.O. Box 196650, Anchorage, Ak 99519-6650 (907) 343-7904 Ref: Proposed Well upgrade for Terrace Heights; Block 1, Lots 19 & 20 To whom it may concern: The existing 4 bedroom house is currently served by a private well and septic system. The existing well is located in the road Right-of-Way and letters of non-objection were obtained in the past; however, the property is in the process of being sold and the lending company will not approve the loan with the well located in the Right-of-Way. To resolve the problem the parties have retained GEG to do a well design and request for a permit. In short, we are requesting for a well permit to drill a new well on property and permanently decommission the existing well. We are unaware o~f~any adverse impacts this installation would have on adjacent wells. If you have any questions, pleaso'~0atact us at 337-6179. Thank you for your assistance. ~ ~-~erely, ,:~' Pres s, P.E., M.S. 3701 E. Tudor Road, Suite 101 * Anchorage, AK 99507-1259 Ph: (907) 337-6179 * Fax: (907) 338-3246 * Website: www.garnessengineering.com I I TH#2 ~ I I / ~,~ I I I \~,~ / / ASPEN HIGHLAND S/D;I I \ / LOT 15, BLOCK 3, I I x / (VACANT) I I ~ I I WlNDCHIMES S/D~ ~T~ ~ ~ / ~PEN HIGH.ND S/D; I I WELL WlNDCHIMES S/D; LOT 2 ~-~ I IELD VE ~~~_ /z ~'~1 L /' ~// ~__ ,~ UPPER D~RMOUN ROAD X ~, / o100, WELL ~us ~ / / ~ / / ~ ~ISTING / / WELL / ~ / / HOLDING /-- DRILLER ' / FIELD VERI~I ~ ~ ~ ~ a~~ KIMBERLY MANOR; ~ ~o~ ~, ~oc~ , LOT 9, BLOCK 1 ~ / / .~______~ ...... . / ~g~ APPROXIMATEx SCALE: ~ ~ WELL LOCATION ~ / / I 1. = 100' I (FIELD ~RI~)~ ~ PREPARED FOR: J PHONE NUMBER: ~ PAGE NUMBER: TE~.ACE HEigHTS; LOT 20~19, ~LOCK 1 PNe SITE P~N 8/1 2/11 UPPER I/eARMOUN RO/, D \ / / ~ -- / EXISTING WELL TO B~'/ -- -- \ / PERMANENTLY \\ / / /DECOMMISSIONED. / / I '":"'' .... :'' ""...' "..':.. I PROPOSED WELL DRILLER IS .. .. RESPONSIBLE FOR VERIFYING ..~~" ..~';.".:.'.. J// v WATER LINE MUST HAVE 10' OF COVER ~'~ OR EQUIVALENT. / ~ % 10' UTILI~ ~SEMENT I I / ~ 1" m 40' CONSULTANTS & GENE~L CO~T~CTORS SEAN LINCOLN 748-9465 LE6AL DESCRIPTION- ~'E ¢;;~;SE, WELL LOCATION DATEs/12/11 (Rev. 01/05)  Municipality of Anchorage Development Services Department Building Safety Division ~.~,~: On-Site Water & Wastewater Program, 4700 South Bragaw St. P.O. Box 196650 Anchorage. AK 99519-6650 www.ci.anchorage.ak.us (907) 343-7904 Page 1 of On-Site Wastewater Disposal System and/or Well Inspection Report Permit Number:. SW060289 PID Numbe~ 017-074-60 JOHN &: GAlL HOWE Wastewater System: n New · Upgrade 7800 U. DEARMOUN RD * ANCHORAGE, AK 99516 ABSORPTION FIELD Ph°ne:(,907)' ' ,345 - 6110 a Deep Trench r'l Shaftow Trench · Bed D Mound LEGAL DESCRIPTION 1 19 &: 20 TERRACE HEIGHTS ../,.:x ",.c" WELL: [3 New r-i Upgrade ,,,,,,~,-"' n. n. GEG, Ltd. ~ I ' ' : TANK SEPARATION DISTANCES aso.t~c o.o~d~.. ·s.T.~.P. Tank F~eld StationTank S~er Une~ ~ w., X / ,oo.. .u..c..., ,oo.. I Lot Line ,/N 5'+ / 500 ANCHORAGE TANK Foundation 5'+ TIMER TIMER 46" Curtain Oroln ~P-$E-13T NOT REQUIRED ~ernorks: REPLACED OLD LIFT STATION (FAT ALBERT) BENCH MARK THAT WAS CRUSHED, WITH A NEW STEEL I'IFT STATION BOTI'OM OF SIDING NEAR POINT 100.00 Inspections performed by: GEG. Ltd. Dates: 1st 2/22/2007 ~,z~.~."~_~,~) ,,- 2nd _~,'~?.'"';'/'i; "-~,,.fi~,, 3rd ~"4- ~ " Development Services Department Approval ] (J'/'~ ~' '~ Reviewed and approved by:. Date: R,viewed and approved by~ate:~ _~. 0 ~ (~i~!: !/~'~; ~'~=, ,,..,,u.sE,. AS BUILT DRAWING SW060289 - Ol 7-074-60 / ~ UPPER DeARMOUN ROAD ' / ~ / I ~ I I ~ I I t I I I I J ~ 1~' WELL ~IUS J I t o I '1 ~.0-,., ... ~ I / I I ~, .. ,'' ."~..~ x...,,. J I · I I~ ... ~... ,;.. I I x t~..J... I I ~ I .:.,.*..: ,, I I -:'r'"? · ~ I ~ I .,..,..:... ~I~NG 1250 / / ~ / ~ / A B ~ / k ST~ 72 47 ~ / ~ ,, , ,, GARNESS ~~ OR~ Ltd. f,~:"~4¢~ "~'~) ~~a~o~s~ - ' .... ~ ~,.x.:.., ..l...t../ ...... :....~ JOHN A GAlL HOWE J 545-6110 2 OF 5 [')~ '.~ '~Y ~'~ .. TERRACE HEIGHTS SUBDIVISION,' LOT 19 & 20, BLOCK 1, K,D.M.~__ ~~A"-"~/'~'/~'~t~ AS-BUILT DRAWING OF SEPTIC SYSTEM UPGRADE o/i/zuu/ AS-BUILT DRAWING '°O,,-O,,-,oNU"B£": NUMBER: SW060289 TOP OF' TANK AT' INLET -- ST3 MH MANHOLE = 99.02 500 GALLON LIFT STATION WITH QUANICS PUMP AND CONTROLS NEW 500 GALLON LIFT STATION TOP OF TANK AT OUTLET = 92.82 GAl{NESS ENGINEERING GROUP, Ltd. [~',~..'~'4~-~L":'F,7~< ,,,,, ~ ~.'~,;7 ~°~'~'2¢~"~ JOHN & GAlL HOWE I ~ .~c.,~o.: I TERRACE HEIGHTS SUBDIVISION; LOT 19 & 20, BLOCK DETAIL DRAWING OF SEPTIC SYSTEM UPGRADE 3/I/2007 (Rev. 01tO5)  Municipality of Anchorage Development Services Department ~* '~%' Building Safety Division On-Site Water & Wastewater Program, 4700 South Bragaw St. ' ~' P.O. Box 196650 Anchorage. AK 99519-6650'~ ~' www.ci.anchorage.ak.us (907) 343-7904 Poge 1 of On-Site Wastewater Disposal System and/or Well Inspection Report Permit Numbe~ SW060289 PID Number: 017--074--60 Nome: JOHN & GAlL HOWE WastewaterSystem: I-I New · Upgrode 7800 U. DEARMOUN RD * ANCHORAGE. AK 99516 ABSORPTION FIELD (907) 345-6110 4 I-IDeep Trench ri Shotlow Trench · Bed rlMound r=lOther LEGAL DESCRIPTION ~' "~: '"~ 1.0 ~o,~. 1 19 & 20 TERRACE HEIGHTS SEE DWG. .. 0.5 n - - - SEE DWG. WELL: D New n Upgrode 15 ~ ~ 600 so. ~-. D 3034/ F-810 / ~ CNG, Ltd. 9/7/2006 SEPARATION DISTANCES ,s.,tic O,o~d;n, as.r.i.P. Tonk Field Station Tonk S...~ U~. ANCHORAOE TANK 1250 Well 100'* 100% 100% -- 25'+ ~"~: STEEL ~ '~ ~"~"~'~': 2 s,,oce wore, ~oo', ~oo', lOO', - - LIFT STATION 500 PREMIER PLASTIC Found=t;on 5'+ 10'+ 5'+ - -- TIMER TIMER 46" Cu~ain Dra;n NON[~ KNOWNi IP-SE-13TI M.O.A. ~emorks: OLD SEPTIC TANK AND CRIB PUMPED. BENCH MARK CRUSHED AND COMPLETELY ABANDONED. Bo'rroM OF' SIDING NEAR POINT "B" THIS IS A SCAT AEROCELL TREATEMENT SYSTEM Inspections performed by: GE(:;. Ltd. Dates: 1st 9/7/2006 3rd 9../7/2006 Development Services Department Approval ~.~'"~ ~/T.T~_~ Reviewed and approved by: Date: R(~viewed and approved b ate:~ PI:RUITNUMeER: AS BUILT DRAWING PARC[LIO NUMBER: SW060289 - O! 7-074-60 / UPPER DeARMOUN ROAD ~ ~N~ 1250 ~ON / A B ST1 50 24 % x / DBL1 60 33 / xx~~/ DB~ 63 36 DB~ 65 40 MH 70 45 C01 57 36 --N~ 5oo ~ON ~AT C03 50 32 ~ PU~P ~o co~o~ UTI 50 33 T C04 82 70-- /FO~(~ C05 84 71 C06 87 73 MT2 88 73 GAYNESS ENGINEERING G~OUP, Ltd. [~:'" 4~:J ~[ '~ CONSULTAN~ & OENE~L CONT~CTORS r, ~J:.:., JOHN · GAL HOWE 345-6t10 2 Or 3 t ~p,y~mess/ AS-BUILT DRAWING Or SEPTIC SYSTEU UPGRADE 9/19/2006 (Rev. 01/0$) PERMIT NUIdBER: AS BUILT DRAWING PARCEL ID NUUBER: SW060289 - O17-074-60 ST1 -] NL'W 1250 GALLON SEPTIC TANK I 500 GN..LON 'PREMIER pLAStiCS" UFT STATION IV~ SCAT PUMP N~ID CONTROLS SCAT RLT[R F1N~ GR.~E TH.~2 TH~'~ ELEVA~ON OF' eoT'roM o~ [XCAVAT1ON - 95.33 ELEVATION OF BOTTOM OF 1EST HOLE - 85.90 15' II',~RT Ot~ PIPE 98.73 (AV~.) EXCAVATION "96.25 OF TEST HOLE i h Rev. 01~05) GARNEsS k}, INEER-i G-bROUP, Ltd.'{ PR~ED FOR: [PHONE NUMBER; I P~[ NUMBER: JOHN & GAlL HOWE [ 345-6110 [ 3 OF 3 V~ TERRACE HEIGHTS SUBDIVISION, LOT 19 · 20, BLOCK I,~ C.J.G. ~ ~E OF WORK: I~Te; DETAIL DRAWING OF SEPTIC SYSTEM UPGRADE J 9/19/2006 From Appltedgtcrosyst~.~s Tue 19 Sep 2006 05:36-'52 AU AY, DT Page 1 of 1 MUNICIPALITY OF ANCHORAGE, BUILDING SAFETY DIVISION 470o SOUTH BRAGAW INSPECTION INFORMATION & HELP: ~43-7962 INSPECTION: VOICE 343-8300 INSPECTION: FAX (907)24g-???? www.muni.org/BSD/Inspections.cfm NAME: Kevin PERMIT#: 06.-~g63 COMPANY: R,sing Son Electric IN=PECT DATE: 9/19!2008 PM PHONE#: 250-1100 PHONE#: PHONE #: ADDRESS: 7800 UPPER DE ARMOUN RD ; LOT20 BLOCK 1 SUBDIVI~,,ION: TERRACE HEIGHTS GRID #: SW2840 COMMENT~ or DIRECTION~-, Lilt Stat[on Thanks Kevin I : , '~ 'TYPE OF INSPECTION: Retro Electrical COMMENT*3: (FOR INSPECTOR USE ONLY) ~enrs MUNICIPALITY OF ANCIIORAGE Development Services Department ' t2 Right of Way Division Department ENCROACIIMENT PERMIT 20061240 Tills AGREEMENT, made this 14th day of September, 2006, by and between Gail P. tlowe and their heirs, administrators, and assigns, hereinafter called "PERMITTEE", and the Municipality of Anchorage, a munielpal corporation organized and existing under its Charter and the laws of the - State of Alaska, hereinafter called the "PERMITI'ER". WITNESSETII: WHEREAS, PERMITTEE is the owner of the following described real property:. TERRACE tlEIGIITS, BLOCK 1, LOT 19 AND LOT 20, according to the official records thereof, on file in the office of the District Recorder, Anchorage Recording District, Alaska, and; WtIEREAS, PERMITTER owns and/or maintains the real property more particularly described as follows: Sixty (60) feet of Upper DeAnnoun Road, immediately to the north of PERMITT£ES property as shown on Plat No. 66-82, on file in the office of the District Recorder, Anchorage Recording District, Alaska, and; WHEREAS, PERMII-IEE has placed a well upon the referenced real property which encroaches 6 feet upon the PERM1TTER'S 60-foot fight of way of Upper DeArmoun Road. NOW, TtlEREFORE, it is mutually agreed between the parlies hereto that: 1. The PERMII-I£1L acting through the Director of Development Services, hereby grants to the PERMITTEE the privilege of allowing well to encroach 6 feet upon the PERMII-IER'S 60-foot fight of way of Upper DeArmoun Road, as shown on "Attachment A," included herewith. 2. The PERMITTEE agrees forever to indemnify, defend, save and hold harmless, the Municipality, its officers and employees, from any and all lawsuits, claims or actions brought to any person for or on account of damage to property or injury, disease, illness or death of persons, including all costs and expenses incident thereto, arising wholly or in par~ from or in connection with the existence of, alterations, maintenance, repair, renewal, reconstruction, operation, use or removal of the encroaching well, as placed upon the PERMITTER'S 60-foot right of way of Upper DeArmoun Road. 3. The PERMITTEE shall not assign or transfer any of the rights granted herein to another individual or company without first notifying and securing the approval of the Director of Development Services. ., This Agreement and Perm{t grants PERMITTEE no inter~st in PERM1TTER'S real property whatsoever, except only the encroachment fights described herein. The PERMITI'ER reserves the right to revoke this permit upon twenty (20) days written notice to the PEP, MI l-I EE. The PEP. MITTEE agrees upon such notice ofrevocation, to move said encroachment(s) from the Upper DeArmount Road Right of Way in which it is placed. Should the PERMHTEE refuse or fail to comply with said written notice, the PERMITI'ER may, without further notice to the PERM1TTEE, remove or cause to be removed 'the encroachment(s), and the PEP, MIFIEE hereby agrees to reimburse the PEPdViI FIER for all ensts incidental to the removal thereof. In addition to the mutual promises heretofore made, the PERMI 1-1 EE hereby promises to pay the PERMIYIER a one-time permit fee of $ ! 15.00. The annual $300.00 is waived. IN WITNESS WtlEREOF, the parties hereto have hereunto set their hands and seal the day and year first hereinabove written. GRANTEE: GRANTOR: MUNICIPALITY OF ANCHORAGE L Frost, J~/ Right of Way Supervisor STATE OF ALASKA ) THIP~D ~UDICIAL DISTRICT ) TIllS IS TO CERTIFY that on this 14~h day of September, 2006, before me, the undersigned, a Notary Public in and for the State of Alaska, duly commissioned and sworn as such, personally appeared Jack L. Frost, Jr., known to me to the Right of Way Supervisor for the Municipality of Anchorage, Alaska, who executed the foregoing instrument, and he acknowledged to me that he 'executed said instrument as the free and voluntary act and deed of said corporation for th6 uses and purposes therein mentioned, and that he was authorized to execute said instrument. WITNESS my hand and official seal on the day and year fa'st above written. STATE OF ALASKA ) ) SS. THIRD JUDICIAL DISTRICT ) TEllS IS TO CERTIFY that on this ~/~_day of~u~., 2006, before me, the undersigned, a Notary Public in. and fpr the State of Alaska, duly commissioned and sworn as such, personally appeared ('rtt~. p/Lrff, d~ , known to me to be the individual(s) named herein who executed the foregoing instrument, and {s)he acknowledged that {s)he did so freely and voluntarily for the used and purposes therein mentioned, and on oath stated that (s)he was authorized to execute said instrument. official seal on the day and year first above written. NM(~ cT~o RmYm .Ps?o nL IECx ~?rea;d for POST IN A CONSPICUOUS PLACE ALL WORK MUST BE INSPECTED IField Inspection Request required 48 hours In advance of start work and 48 hours In advance for final Inspection. Ca11(907) 343-~206 (voice recorde~') for scheduling Inspections. . I MUNICIPALITY OF ANCHORAGE epartment RIGHT OF WAY DMSION 4700 BRAGAW STREET TELEPHONE (907) 343-8240 FAX (9O7) 343-825O Status: OPEN Date Issued: 09/14/2006 Last Updated: 09/14/2006 RIGHT OF WAY PERMIT Type: ENCROACHMENT Date Applied: 08/30/2006 Construction Start Date: 0010010000 Permittee: GAlL P. HOWE Gen. Contractor:. Utility Account: Primary Inspector:. WALTERS, MICHAEL S. Site Address: 7800 UPPER DEARMOUN ROAD Subdivlslon: TERRACE HEIGHTS Work Location: 20061240. Grid: 2940 Latest CO#: 0 Issued By: PWLJM Contact: GAIL P. HOWE (907) 345-6110 Contact: Building/Land Use Permit #: Cross Street: OLD RABBIT CREEK ROAD Lot: 19, 20 Block/Tract: 1 EAST OF OLD RABBIT CREEK ROAD, NORTHERN PROPERTY BOUNDARY OF LOTS 19 AND 20 Original WELL ENCROACHES 5'7" INTO 60' RIGHT OF WAY OF UPPER DEARMOUN ROAD. Work Description: Latest Work Description: Partial Road Closure: [] Full Road Closure: [] TCP Required: [] Pavement Break: [] Winter Requirements: [] Safety Device Required: [] Driveway: [] Approved Drawings: [] Special Provlslons: [] Other (see back): [] Traffic Control Plan Information (Most Recent) Closure Type: From: To: Agencies Notified - Fire/Police: [] State of AK: [] People Mover: [] School Bus: [] Approved? [] Summarized Financial Transactions (as of 911412006) Last payment date: 09/14/2006 Total fees: $115.00 Total payments: $115.00 Total Prepay: $.00 Last payment comments: CHECK #3261 FROM GALE PARTCH $115 See reverse for requirements I remarks I construction notes I special provisions. ! have read and understand both sides of thls permit. I agree to the terms and conditions; and I certify that all work Iwill comply with federal, state, and munlcipal codes and regulations and the provisions of this permit. Signature: Date: Mmficipality of Anchorage PO. Box 19C~3,q0 * Anchorage, Alaska co0519-6(150 * TelePhone: (907) 313-7900 * Fax: (907) 3!3-79g'/ I~yslcal Address: -~700 Braga~' Street * Anchorage, Alaska 99607 * ~a,. m u hi.or t~/o] a nnl np Mayor Mark Beglch Planning Dcpartmcnt September 12, 2006 Gall P. Howe P. O. Box 110277 Anchorage, AK 99511 Dear Ms. Howe: This letter is in response to your request for a determination of the nonconforming status of the property located at 7800 Dearmoun Road. {Parcel: 017-074-60, Grid: SW2940) This determination is based on the follow~g irfformati0n: · Terrace tIeights, Block 1, Lots 1'9 ahd 20 .w. as createdby~lat 66-82, filed June 27, 1966. · The property was zoned R-6 on June 6, 1974. · Anchorage Municipal Code 21.40,050.F.l.a require~ a mi.nimum lot size of $4,450 square feet, and allows the inclusion ofone'halfofthe abutting dedicated fight-of-way and a 1% variation in lot size for the p ..urp0. se of de{e.rmi.'ning conforn~_ity. · Anchorage Municipal Code 21!40.080(G) rei/luirbs a front'yard setback ofS0-feet, a side yard setback of 25-feet, and a rear yard/~ctb~ck 0f $0Zfeet. · Building permit number 06-827i~-i.ss~e~':~uly 10;12006 for a retrofit, to replace unit heater. · Municipal property apprais~i r. ordl indichi'6 a ~i.figle-family on a 40, 744 square foot lot, (lots 19 and 20).. · Municipal property inven{ory'i;heets i~di~.~Teii'h;T°llowing:' · November 22, 1974, new h. ou~e ~t~mate~60~A.complet.e and 100% for 1975. · February 16, 1978, interior inii~e~iion, ~'~emefit 50% finish, one bath down, one up, four bedrooms.. · July 5, 1978, no change, unfinished basement, exterior only. · September 19, 1979, re-measured garage, is 24x24. · An as-built survey by I.znd & Associates dated August 24, 2006 shows a house on Lot 20 and an encroachment onto Lot 19. · An aerial photo dated May 19, 1974 shows vacant land. The following conclusions are drawn from the above information: Lot 19 and LOt 20 have less than the minimum area required in the R-6 district. Since they were platted prior to zoning, the sub]ect properties are Legal Nonconforming Lots of Record and are governed by AMC 21.55.020. Community, Security, Pros_pcrity Nonconforming Status determination Terrace Heights, Block 1, Lots 19 & 20 Page2 Per AMC 21.55.020.A the yard and lot coverage requirements are "those of the zone with the largest lot area requirement within which the lot would be conforming." The subject property would be conforming in the R-lA use district. Therefore, the following requirements apply to the subject properties: Front yard: 20 feet Side yard: 5 feet Rear yard: 10 feet Lot coverage: 30% maximum All other R-6 standards apply. The house encroaches entirely into the required 5-foot East side yard setback. The above information indicates that the house was constructed after zoning but before 1986. AMC 21.55.040 (D) (1) allows for existing structures with dimensional encroachments into required yards which were constructed prior to January I, 1986, may continue in existence provided the encroachment does not pose a life/safety hazard." The location of the house does not appear to pose a life/safety hazard and is granted a Certificate of Nonconforming Encroachment and enjoys all of the protections and privileges afforded a nonconforming structure under AMC 21.55. The house is encroaching 2.2 feet onto Lot 19. The encroachment of the house onto the adjoining lot (Lot 19) along the East property line is a civil matter between property owners and not an issue with the Municipality of Anchorage. This letter does not grant permission for the encroachment onto an adjoining lot. Note: This determination is based on the information listed above, which was provided by~e applicant orwas in the files ofthe administrative official. If additional information is obtained, or the information provided above is later determined to be inaccurate or false, and materially changes the conclusion herein, the administrative official may revise or revoke this determination. Anchorage Municipal Code Title 21 is available on the intemet at http://www.municode.com. If I can be of further assistance, please contact me at 343-8380. Respectfully, SEP-15-2f~6 gS:J.t PRUDI3,1TII:~ $1qC~ IAIITE P.132 Municipality of Anchorage Anchorage Water & Wastew, ater utility ff~_~.~ Gall P. Howe PO Box 110277 Anchorage AK 99511 .September 14, 2006 Re: Terrace Heights B1 Lt 19, 20 (Grid SW2940) Request for Letter of Non-objection to EncrOachment The Anchorage Water & Wastewater Utility received a request on your behalf f~om Gale Partch on September 13. 2006, for a letter addressing AWWU's position regarding an existing ~ located in ~Announ Road. According to the site plan as-built, lhe well is located approximately 10 feet west and 5.7 feet north of the norltmast property comer of Terrace Heights B1, Lot 20. AWW1J has no utifi6es located in the Upper DeArmoun Road right-of, way, has no ebjeotion to the encroachmenL and hereby issues this letter with stipulations to allow the encroachment of tile existing well. By continuing to keep the well in tile right-of, way the property owner(s) agrees to lhe following: 1. AWWU will be held harmless, now and forever, for any damages or injury to any person as a result of the encroa~; 2. All applicable codes and regulations will be observed and maintained within the right- of-way; 3. This letter will in no way preclude AWWU from full use and enjoyment of its rights within any potion of lhe easement;, 4. The property owner shall pay any additional and/or ex~aordinary costs incurred to accxx'nmodate the encroachment dudng any future required constmctk~n or reconstruction of AWWU facilities; Including but not limited to relocating the well or decommissioning the well and connecting to public water;, AWWU's non-objection does not Imply other approvals that may be required for this encroachment; and, AWWU does not provide a position for any other parcel or utility impacted by the en~oachmenL S~P-IST2~ ~8:11 P~i~I)~D'~II~L JA(]< I~HITE p.~ Should you have any questions, please call the AWWU Planning Section at ~64-2739. ~~a ,.. Engineering Technician III t TOTAL P. EL',',~ SEP-14-2II~, 10:19 1:gJDENTiq.. JaCK I.~IITE P.04 September 13, 2006 F_.NSTAR Nalural Gas Company A DIVISION OF SEMCO ENEI~GY ~nglneering'IX'partment 401 E. Iut~'natlonal Airport Road. P. O. Box 190288 Anchorage, Alaska ~)519-0288 (907) 334-7753 FAX (0o'7) 334-7798 Ms. Gaile Howe P.O. Box 110277 Anchorage, Alaska 99511 Re: Letter of Non-Objectlon GHd: 2940 To whom it may concern: ENSTAR Natural Gas Company has no obj~tlon lo an exlsti~g well ~croachm~t imo thc Sixty F~t (60 1t) wide DeArmoun Road Right of Way situated adjac~ to the North boundary line of Lot 20, Block 1, Terrace Heights Subdi~sion, according lo Plat No. 66-82, located within thc SWl/4, Scction 25, Tow~shlp 12 North, Range 3 West, $~ward M~rldian, Records of the Anchorag~ Recording District, Third Judicial Dislrici, Sta~ ofAla~lca_ Acceptance and use of Ibis lct~er of non-obj~-tlon by yourself, your heirs, 3~mr a-~il~s, or your successors, vie constitute agrozment 1o the following stipulations: * ENSTAR will be held harmless, now and forever for any damages or injurg to any lX~On or properly as a result of this cncmachmcnL · Any ENSTAR facility ~maged or destroyed, as a result of this eacroacluncat will be repaimt at no cost lo ENSTAR. · Any corts incurrcd by ENSTAI~. for special construction necc.~itatcd by this cncmachment will be borne b7 thc propcrty owner. · All applicable safety code ~gulatiom will be obse~.d and maintained. · This letter of non-objection will in no way preclude I~STAR from full usc and ~njo~maeat of its rights within any poi~ion of its right-of, way. $1nce~cly, Andrew Frais~r ENSTAR Natural Gas Company co: File ACS Alask~ Communlc~i~ns Systems Scvtcmbcr 13, 2006 Oail P. tlowc P.O. Box 110277 Anchorage, Alaska 99511 AC;S has Isu ubj~'~tlu, t~ dso c.~o~.hmcnt o£the w~ll ~nto the platt~l o~mont r~E~ht e~'way ot'Upl~r r,.aA ~nnn I~ e~d f~r I .or ~7.0. FIIk i. Ten'a~e Hei£hts. as depicted on the as-bulk drawinR submitted. Acceptance and use of this letter of non-objection by yourself, your heirs, your assigns, or your ACS will be hHd harmless, now nad forever, for any damages or injury to nay person or Any ACS facility damaged or destroyed as a result of this encroachment will be repaired at no cost to ACS. Any costs [ncun~d by AC~ for special ~:~trut;tiozz necessitated by thLs cnctoachmcnt will be borne by lh~ property owner. 4. All applicabla ~af'o~ oodo r~b-ulatio~ will be ol~er~d ~d main~ined. This letter of non-objection will in no way preclude ACS from full use nad enjoyment of its rights within any portion of its right-of-way. Sioccrcly, ~, Outside Pbmt Engin~rlng ACCEPTANCE: DATE: Grid # 2940 600 Telephone Avenue Anchorege, Alasl~a 99S03-6091 tel 907.$64.1000 www.~cs~laska.co~n 10:19 ~RUDE~TlPL JAC~ I~HI~E P.8~ September i 3. 200~ Oail P. lloxve(Ov~er) ?g0O Upper DeArmoun Rd. Anchor-gu. AIa.~Ln, 99516 To whom this ma)' concern, Subject to your agreement to indcm~ry Ihe company ~,~ ~ fo~ ~Iow. ~l ~b]¢ l~c. 1O.~d ~0 RI~[: I. T~w. Tt~i~ht~ R.~i~sion. ~no~ ~ ~g~ U~ DcA~oun Roa~ Anchorage Ala~h, 99516), ~ city ~d ~2940. Th;,~ I~.,~,' nf n^noe, l'~o~tlon [n n~ w~' ~zeclud~ GC[ CaMe from full ~ end cajo~m~t of~y righ~ k may ~w wi~ ~y potion or~c u~llty os~ent and or the gght-of- cx~ordin~y cos~ incu~d during any ~rc ~ui~ cons~uc6on, r~ir or paid by the ~o~y owner. forever, for ~y damage, cos~% cx~e (including rc~oaablc attomcl's fc~), Iiabiljti~ indicate your acceptance by signing and rctu[ning ~his letter to mysell'ac ~he address bclow._I.f. ,a. ot_~ned and returned to GCl?i.~hln 30 d~ys of i~suanee~ this Sincerely, Prope~y~)~vncr/$ signature (Void until sig~ocd by thc Propert~ Owncr/s and returned.) Rob l.la~ca CAD Operator Level E-frail- IM1AN,gEIq'I ~,O C(.CO M g.~CC/~ t'Jul) AO8-O1 F~x ~ (907) 86g-B580 $~ptembe~ 13, 2006 Gall P. Howe P.O Box 110277 Anchorage, Alaslo~ 99511 Letter of Non-objcction for Existing Well Lot 20, Block 1, Terrace Heights Subdivision SW½ of Section 25, TI2N, R3W, S.M., Alaska Grid 2940, OB06034, PID #017-074-60 D~ar Ms. Howe: Chugach Electric Association, Inc. (Chugach) provides its ~on-objcction to the existing dated August 24. 2006. It must be your understanding that the location of thc existing well ia the road fight of way is at your risk, and that this non-objection i~ givca wifl~out prcjudice to Chugaeh'~ full enjoyment of any and all fights it may have in the mad fight of way. Enclosed for your use arc Chugach' s Etectrical Facility Clearance Requirements, Wh~t is an Easement? handora, and the locale Call Center card. If you have any questions, please call Susan Tmskett, Right of Way Agent, at 7624735. Sincerely, Jim K, Topolski Manager of_I ~,~d See&es Enclosure Chugach Electric Association, Inc. 5601Elearan O,ve. P O 8ox lg~30O. Anc~o~o~*, Alasla 99519-6300 * 1907156.1.7.~94 Fax [9071562'O027 · lB001~78'7494 MUNICIPALITY OF ANCHORAGE Development Services Department On-Site Water & Wastewater Program 4700 South Bragaw Street P.O. Box 196650, Anchorage, AK g9519-6650 (907) 343-7904 ON-SITE WASTEWATER DISPOSAL SYSTEM PERMIT Upgrade Date Issued: Sep 01, 2006 Expiration Date: Sep 01. 2007 Permit Number: SW060289 Legal Description:., H,e;gl~f$ BLOCK 1 LOT 20 Design Engineer: 0855 GARNESS ENGINEERING GROUF Owner Name: JOHN & GAlL HOWE Owner Address: PO BOX 110277 ANCHORAGE, AK 99516- Parcel ID: 017-074-60 Site Address: 7800 UPPER DEARMOUN ROAD Lot Size: 40744 SQ. FT. Total Bedrooms: 4 Permit Bedrooms: 4 This permit is for the construction of: [] Disposal Field [] Septic Tank [] Holding Tank [] Privy [] Private Well [] Water Storage Ail construction must be in accordance with: 1. The attached approved design. 2. Ail requirements specified in Anchorage Municipal Code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations ( 18AAC72 ) and Drinking Water Regulations ( 18AAC80 ). 3. The engineer must notify DSD at least 2 hours prior to each inspect[on. Provide notification by calling (907) 343-7904 ( 24 hours ). ( Not required for a Water Supply Permit only ). 4. From October 15 to April 15. a subsurface soil absorption system under construction during freezing weather must be either: A. Open and closed on the same day. B. Covered, sealed, and heated to prevent freezing. 5. The following special provisions. THIS PERMIT IS ISSUED FOR TERRACE HEIGHTS, BLOCK 1 LOT 20 Municipality of Anchorage Development Services Department Building Safety Division On-Site Water and Wastcwatcr Program 4700 Bragaw Street P.O. Box 196650 Anchorage, AK 99519-6650 www.ci.anchorage.ak.us (907) 343-7904 Waiver Review Worksheet WRY: 0054 PI~: 017-074-60 HA~ermi~ SW 060054 Date Received: September 1, 2006 Legal Description: Terrace lleights, Block l Lot 20 Engineer:. Jeffrey Garness, P.E. Garness Engineering Group 3701 E. Tudor Road, Suite 101 Anchorage, AK 99507 Applicant: John and Gail Howe Waiver Requested: Lot Line Waiver Criteria: Geology Points: A. Water Table B. Soil Sorption C. Permeability D. Water Table Gradient E. Horizontal Separation Total: Waiver Is Granted: X Waiver is not Granted: Est Conditions or Reasons for above: Date: 9~1/~¢} By: Deb Wg~,kenfus~ Name of Reviewer Rec#: 23124 Amount: $175 Date Paid:9/1/2006 Municipality of Anchorage Mayor Mark Begich September 1, 2006 Jeffrey Garness, P.E. Garness Engineering Group 3701 E. Tudor Road, Suite 101 Anchorage, AK 99507 Subjeet: Waiver Request for Terrace Ilcights, Block 1 Lot 20 Waiver Request WR#: 0054 Parcel ID # 017-074-60 SW 060054 Dear Jeffrey Garness, P.E.: Your request for a waiver of the required 10 feet horizontal separation from the absorption field to the property line has been approved. The approved separation distance is 0.0 feet. This waiver approval applies to the existing absorption field to property line separation only. Any future upgrade to the on-site wastewater disposal system will require all ......... ~patatioxx di~toa~:c~_b~ mci o~ unoth~_'dpl~p_v/d! fi~n] fl:i~, d~pa~ tmc~lt If there are any further concerns or questions regarding this waiver, please call our office at 343-7904. Sincer_ely, Deb Wocken f~ Civil Engineer On-Site Water & Wastewater Program Community, Security, Prosperity Municipality of Anchorage Development Services Department Building Safety Division On-Site Water & Wastewater Program 4700 Bragaw St. P.O. Box 196650 Anchorage, AK 99519-6650 www.ci.anchorage.ak.us (907) 343-7904 ON-SITE SEWER/WELL PERI'lIT ~,PPLICATION FOR ,b, SINGLE FAHILY DWELLING Parcel I.D. Property owner(s) JOHN &: GAlL HOW[ Mailing address P.O. BOX 110277 ANCHORA~;[, Site address ,/~)~) L)~ir'~"~ ~t-~l'~l)l.') I'1~'~ Day phone Zip Code 345-6110 Legal description (Sub'd, Block & Lot ) TFRRACE HEIGHTS: LOT 20. BLOCK 1 Legal description (Township, Section & Range) Lot Size f-~; ~/-~/ Sq. Ft. I't/A Number of Bedrooms 4 THIS APPLICATION IS FOR ( [~all that apply): Absorption Field Septic Tank Holding Tank Privy Private Well Water Storage [] THIS APPLICATION IS AN: [] Initial [] [] Upgrade [] Renewal [] I certify that the above information is correct. I further certify that this application is being made for a Single Family Dwelling and is in accordance with applicable Municipal codes. GARNESS ENGINEERING GROUP, Ltd. Permit/Rush Fees: Date of Payment: Receipt Number:, ~-~ (Rev. 11/05) Waiver Fees: fl~ Date of Payment: Receipt Number. GARNESS ENGINEERING GROUP, Ltd. CONSULTANTS & GENERAL CONTRACTORS ............. , August 3, 2006 Municipality of Anchorage Development Service Department On-Site Water & Wastewater Program 4700 South Bragaw Street P.O. Box 196650, Anchorage, Ak 99519-6650 (907) 343-7904 Ref: Proposed Septic Upgrade for Terrace IIelghts; Lot 20, Block 1, To whom it may concern: The existing 4 bedroom house is served by a private well and septic system. The septic system is in a state on failure and needs to be upgraded. We are proposing to install a new 1500 gallon S.T.E.P. tank with SCAT aerocell controls, a SCAT trickling filter and a bed type drainfield. Two test holes were excavated on the property. The drainfield will be designed around the 30 foot radii of these test holes. Comments regarding the design are summarized as follows: 1. SOILS: See the attached logs which shows the soil classifications, groundwater monitoring, and the percolation test results. 2. DRAINFIELD DESIGN: See attached design drawing for drain field specifications. 3. SURFACE WATERS: There are no surface waters within 100 feet. 4. TOPOGRAPIIY: As can be seen on the attached topography drawing the average topography in the area of the proposed drainfield is generally flat. In short, there are no slope concerns. 5. LOT LINE WAIVER: We request a 0 foot lot line waiver to the west lot line on Lot 19. We are unaware of any adverse impacts this waiver would have on adjacent lots. 6. WAIVER TO IMPERMEABLE SOIL: As shown on the attached soil log there is an impermeable layer of soil at approximately 3 feet. We request that your department waive the vertical separation from impermeable soils from 6 feet to 4 feet. Justification for this reduced separation distance is summarized as follows. The effluent being discharged to the drainfield is from a Scat treatment system, which has CBOD and TSS levels that are expected to be less than 15 mg/L. In addition, the total nitrogen levels are expected to be less than the effluent from a lined Intermittent Sand Filter (effluent from an ISF can be discharged into a drainfield that is only 4 feet from bedrock and impermeable soils) · There will still be a 6 feet separation distance between the bottom of the drainfield and groundwater · There will be no discernable benefit (reduced BOD, TSS, or total nitrogen) achieved by passing the effluent through 6 feet of soil vs. 4 feet of soil. It is generally agreed upon that the pathogen 3701 E. Tudor Road. Suite 101 * Anchorage, AK 99507-1259 Ph: (907) 337-6179 * Fax: (907) 338-3246 * Website: www.gamessengineering.com reduction occurs within the first 4 feet of soil, hence thc 4 feet required separation distance to groundwater. It is reasonable to assume that by the time the effluent passes through 2 feet of imported sand and then 2 feet of the insitu 20 minute per inch soil that the BOD and TSS levels will be essentially zero (0). It is further assumed that there will be no more reduction in total nitrogen achieved by building the mound several feet higher. The highly treated effluent will probably not see further reduction in nitrogen levels without introduction of a carbon source (as is the case with ISF effluent). We are unaware of any adverse impacts this installation would have on adjacent wells or septic systems. lfyou have any q,~estions, please contact us at 337-6179. Thank you for your assistance. Presi ~VOTE: dttached ~s a site plan drawing, a design drawing, one soil log, which are all part of the design paclcage for this septic systetn. (Contact G.E.G. l. td. for 7 page ¢onstruction specification letter.) 3701 E. Tudor Road, Suite 101 * Anchorage, AK 99507-1259 Ph: (907) 337-6179 * Fax: (907) 338-3246 * Website: www.gamessengineering.com I I I T + I I % . I I I ~ ! .... ~ LOT 15, 8L~ 3, I I ~%~. LOT 14, BL~K 3. I I ~N~HIMES S/D; LOT 2 I I ~N~HIM~ S/D; LOT 1, I I I I 1% ~/ ~ ~ , ~/ % PROPOSED / ~ s[~ ~ ~lz/ ~ .... ~:-- -~---~v ..... : , //// -/ ~' WEL~ ~fUS 't~ x s~: / ___~ · II .... ' ' ~ 0 ~o~[,~,~ · o~ ~[ ~o~,o~ ~ ~"":' k' ~ ~ ........ :'"'~ JOHN ~ GAlL HOWE 345-6110 I OF 5 ~ ~..~< lrey~;omess.: ~'~ TERRACE HEIGHTS; LOT 20~19, BLOCK 1 B.F,M. ~q~7~ "'~.~3~/~ SITE P~N FOR PROPOSED SEPTIC SYSTEM UPGRADE 7/25/2006 (Rev. NUMBER OF BE)ROOla$: 4 ~ONS PER ~Y (GPD): ~ / .~o~ ~/~:~o ~,../,.~. UPPER DeARMOUN ROAD M.O~ ~PR~D ~O ~L~: 2.0 ~ ~ 0 I I ~ER ~T PERT~NS TO ~ms o~sec.. / ~ ~ CO~ GEO. ~ PR~EED[NG FO~D ~ ~lS INfO, ON. ~E ENGINEER. PROPE~ O~ER ~REE ~T ~ ~ ~REE TO ~C~ ~E ~RUS ~D ~ . ~NED~C 9 ~ [ / S.T.E.P. T~K ~ ~!2 ~o ~PRO~SED / ~ PR[P~O FOR: PHONE NUMBER P~E NUMB~ i ~J' J'~ ........... DESIGN FOR PROPOSED SEPTIC SYSTEM UPGRADE 8/~/2006 MT SCAT A~ROC£LL UNIT's. / I eo ~o O0 II Oc° I 0~ TO S.T.E.P. TA~K 0 4O MT I 8C)ITOId OF' ~XCAVATION GARNESS ENGINEERING GROUP, Ltd. JOHN · GAlL HOWE I 345 6110 I 3 OF 5 PROPOSED DESIGN FOR SEPTIC SYSTEM UPGRADE 8~5~2006 ICa 15, WlNDCHIMES B/D; HOUSE BLOCK PREPARED FOR: PHONE NUMBER: $45-6110 7/2s/2~ ................. · "' , ¢o~o"~"~o~ ~· DEP~ ~ ('~.~ORO*N,CS ITEST HOLE ~IAI ' ' SOIL C~SSIFICATIONS I GM CL x t ~ / ~ / ~ / GC OL N ~ / ~ / · : ? s. c. X-' -" '- SH OH ' ' SC [[l SM/GH DEPTH TO GROUNDWATER DATE 9' 7/21/2006 -~ 4' B* 7/24/2006/~/~ ~.~' 7/=~/~ ¢- ............ 11 DATE ~EADING CLOCK NET TIHE WATER LEVEL NET DROP TIHE (HINUTES) READING (INCHES) 7/24/2006 1 2:52 - 6- _ 1 2 2 ~:22 50 5 1~ 5 5:22 - 6- _ 4 5:52 50 6" O' 14 5 5:52 - 6- _ 6 4:22 50 6' 15 16 17 18 19 PERCOLATION RATE 120+ (HIN./INCH) PERC. HOLE DIA. 6 (INCHES) TEST RUN BETWEEN 1.0 FT. ~D 1.5 FT. 20 A FO~ HO~ PRESO~ WAS PERFORHED: ~ YES D NO SOILS LOGGED BY: SU~N OSWALT PERCOLATION TEST PERFORNED BY: BEN~ MAUS COHHENTS: PERFORMED BY CRC, Ltd. I, JEFFR~ A. GARNESS, CERTI~ T~T THIS WAS PERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPAL ~UID[LIN[S IN EFFECT ON THIS DATE: DEPTH TO GROUNDWATER DATE 9' 7/21/2006 4' 8" 7/24/2006 ~,o' GARNESS ENGINEERING GROUP, Ltd. CONSULTANTS & OENEP, AL CONTRACTORS ·.. ISOIL LOG PERCOLATION TESTI ............................ LEG~ DESCRI~ON: TER~C[ HEIC~S; LOT 20, BL~K 1 PERFORMED FOR: JOHN ~ ~L H~[ DATE: 7/21/2006 (LOWER BENCH) ~PTH ~ '~'~ O~O~N,CS iT[ST HOLE ~ 1 BJ I1 111111 SOiL O~SSIFIOATIONS II ~l u~PE~ ~ou~ R~ll GM CL ~ //I ~ ~x // GC OL N ~ ~ / SW MH sP CH SM OH ' ' SC GROUNDWATER __ g' 7/21/2006 -~ -- 4' 8" 7/24/2006 -~/ ......... ~ ............................... ~.¢ ~ ~/zs/~~ ........... ~ ......... ~ .... 11 DATE READING CLOCK NET TINE WATER LEVEL NET DROP TINE (HINUTES) READING (INCHES) 12 7/24/2006 1 2:52 - 6- _ 2 3:22 30 5 3/4" 1/4" 15 5 5:22 - 6- - 4 5:52 50 6' O' 14 5 5:52 - 6- - 6 4:22 50 6' O' 15 16 17 18 19 PERCOLATION RATE 120+ (HIN./INCH) PERC. H~E DIA. 6 (INCHES) TEST R~ BETWEEN 5.5 FT. ~D 4.0 FT. 20 A FOUR HOUR PRESO~ WAS PERFORHED: ~ YES ~ NO SOILS LOGGED BY: SU~N OSW~T PERCOLATION TEST PERFORHED BY: BEN~ UAUS COHHENTS: PERFORMED BY GEG, Ltd. I, JEFFR~ A. GARNESS, CERTI~ T~T THIS WAS~ PERFORMED IN ACCORDANCE W~H ALL ~ATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE: DEPTH TO DATE GROUNDWATER 9' 7/21/2006 4' 8' 7/24/2006 .~.~ , CONSULTANI'$ & GENERAL CONTRACTORS~~ ~I'/~7~- ISO;L LOG - PERCO~TION TESTI~ IIIlll~ .., .......... ....... /~A/ ~r~R ~ . TER~CE HEIG~S LOT 20, BL~K 1 r y A. Gorness. ~EPTH ~ IT ST HOL I1 111111 SOIL C~SSIFICATIONS I ~ UPP[R ~MOUN GW ===== ORG I I ~ I ~ GP ML ~ I GM ~ CL ~ / ~ / GC OL N ~ / % ~ SW MH / SM OH ''  SM/GM SC DEPTH TO GROUNDWATER DATE 9' 7/21/2006 ~ - ~ 4' 5" 7/24/2006 ~.~' 7/z~je~ ~ ...... ~ ...... x ~[: ~o SP I ~ ~ ~' ~' 11 DATE READING CLOCK NET TIHE WATER LEVEL NET DROP TIME (HINUTES) READING (INCHES) ~ = ~/~/~oos ~ =:s= - s' - 2 5:22 ~0 4" 2' 15 5 5:22 - 6- - 4 ~:52 50 4 ~/2" ~ ¥2" 14 5 5:52 - 6- - 6 4:22 50 4 I/2' 1 1/2" 15 16 17 19 PERCOLATION RATE 20 (~IN./INCH) PERC. HOLE DIA, 6 (INCHES) TEST RUN BETWEEN 1.0 FT. ~D 1.5 FT. 20 A F0~ HO~ PRES0~ WAS PERFORHED: ~ YES ~ N0 SOILS LOGGED BY:, SU~N OSW~T PERCOLATION TEST PERFORHED BY: BEN~ UAUS COMMENTS: ~ ~v~ ~, ~ l~.c~ ~ PERFORMED BY GEG. ~N. I. ~EFFR~ A. OARNESS. ~ERTI~ T~T THIS WAS ~ERFOR~ED IN WITH AL~ STATE AND ~UNICIPA~ ~UIDEUNE$ IN EFFECT ON THIS DATE: DEPTH TO GROUNDWATER DATE 9' 7/21/2006 ~ 4' 3" 7/24/2006 ~.o' 7/z~/~ CONSULI'ANT$ & GENERAL CONTRACTORS ~ ." ISOIL LOG - PERCO~TION TESTJ ~R~CE HEIC~S; LOT 20, BL~K 1 LEG~ DESCRIP~ON: (LOWER BENCH) f~e~ORGANICS JTEST HOLE ~2BI SOIL C~SSIFICATIONS I t I I GM CL GC 'OL · · SP CH SM OH DEPTH TO ~!~+ GROUNDWATER DATE 9' 7/21/2006 ~ 4' 3" 7/24/2006 ~.~' ~/~/~ c .............. ~ ......... ~ .... 10 SP " 11 DATE READING CLOCK NET TIME WATER LEVEL NET DROP TIHE (HINUTES) READING (INCHES) 12 7/24/2006 1 2:52 - 6- _ 2 5:22 50 6' O" 15 5 ~:22 - 6- - 4 5:52 50 6' O" 14 5 5:52 - 6- - 6 4:22 50 6' O' 15 16 17 18 19 PERCOLATION RATE ~ 120+ (HIN./INCH) PERC. H~E DIA. 6 (INCHES) TEST R~ BETWEEN 5.5 FT. ~D 4,0 FT. 20 A FOUR HOUR PRESO~ WAS PERFORHED: ~ YES D NO SOILS LOGGED BY: SU~N OSWALT PERCOLATION TEST PERFORMED BY: BEN~ ~US COHHENTS: * MAY HA~ BEEN IN~UENCED ~ CROUND PERFORMED BY GEG, Ltd, I, JEFFR~ A. GARNESS, CERTI~ T~T THIS WAS ~ER[ORMED IN ACCORDANCE W~H ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE: ~[~0~ DEPTH TO GROUNDWATER DATE 9' 7/21/2006 ~ 4' 3" 7/24/2006 s.o' ~/~/~ n~Sep, 1. 2006~ 8:09^~/ Garness Engineerins Group, Ltd. N0,5001 P. 2. e~/e2 L ' ~ecording Diet: 301 - Anchorage A s 8/31/2006 12:13 PM Pages: 1 of 1 K A .This £asement is by GAIL P. shall become cf£ecdvc on it is thc benefit of all owners and future ow ~crs of thc subject Recitals. WH£REAg, Owner is Lo;.s 19 and :20, Block I, T£RRAC;.£ ?let No. 66-82, Records or Alaska; and :~ accol iomge Recordln WH£REAS, to install real properties described above over across thc described above. WHEREAS, Owner r~in desires to access to said septic system t NOW, br the re I. grant a I Of Owner's properties for thc which will cross through and over the property 2. Said e~semcnt shel be fur purpos~, a private septic system, shall benefit to and binding upon the gn properties, OAILP, STATE OF ALASKA THIRD JUDICIAL DISTRICT ,~ Thc foregoing instru rant wu '__/~,~,/./ZT)/- ,2006, by iAIL P. HOWE. a married person, whose adclress is . .. (o ~s ;Owner". 'This Easement the land and shall in.ur~ toand be for ng described rcal properties: thc official plat thereof filed un~le~ Third Judicial Oisvict,' State of ~d operate a septic system upon thc property linc between thc two lots perpetual septic e~sement to pr0vidc enhance of the septic system. ova, Owner declar~ as follows: casement through and over a ponlon ~intcnance of a private septic system ; two IoLs, dlatlon and continued maint~nanc~ of ,attics described herein and shall be a shall hereafter acquire title to said before me this ~/ day of' ~laska Sep, I, 2006 8:09AM P. 3 TOTRL P. 02 · :-C RTIFICATE Parcel I.D. 017-074-60 1. GENERAL INFORMATION Municipality of Anchorage Development Services Department Building Safe~ Division On-Site Water & Wastewater Program 4700 Elmore Road P.O, Box 196650 Anchorage, AK 99519-6650 www.muni.org/onsite (907) 343-7904 OF ON-SITE SYSTEMS FOR A SINGLE FAHILY DWELLING Expiration Date: Complete legal description Location (site address) Current Property owner(s) Mailing address Lending agency Mailing address Real Estate Agent Mailing address TERRACE HEIGHTS; BLOCK 1, LOT 19 &: 20 7800 UPPER DEARMOUN ROAD *ANCHORAGE, AK 99516 SEAN LINCOLN Day phone 748-9463 7800 UPPER DEARMOUN ROAD *ANCHORAGE, AK 99516 Day phone CYNDI PARTCH W/ PRUDENTIAL Day phone 44-0-7775 .3801 CENTERPOINT DRIVE *ANCHORAGE, AK 9950.3 Unless otherwise requested, COSA will be held by DSD for pickup. 21 NUMBER OF BEDROOMS: 4- 3. TYPE OF WATER SUPPLY: TYPE OF WASTEWATER DISPOSAL: Individual Well · Individual On-site · Individual Water Storage [] Individual Holding tank [] Community Class Well [] Community On-site [] Public Water System [] Public Sewer [] The Municipality of Anchorage Development Services Department (DSD) Issues Certificates of On-Site Systems Approval (COSA) based only upon the representations given in paragraph 4 by an independent professional civil engineer registered in the State of Alaska. Certificates of On-Site Systems Approval are required for the transfer of title (except between spouses) for properties served by a single-family on-site wastewater disposal and/or water supply system. DSD also issues COSAs upon request to homeowners. Certificates of On-Site Systems Approval are valid for 90 days from the date of issue for properties served by a private or Class C well and may be reissued with new water samples. (Certificates may be reissued for a period of up to one year with valid water samples.) Certificates are valid for one year for properties served by Class A or B wells or a public water system. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. 4, STATEMENT OF INSPECT~ON BY ENG!NEER As certified by my seal affixed hereto and as of t,5e validation date shown below, I verify that my investi~qafion, based on procedures outlined in the Certificate of Qn-Site Systems Approval Guidelines for this application, sho~4~ that the on-site water supp!y and/or wastewater disposal system is (are) safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify t,Sat based on the information obtained from the Municipafity of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation. Name of Firm GARNESS ENGINEERING GROUP, Ltd. Phone 557-6179 Address 5701 Eo TUDOR ROAD, SUITE 101 * ANCHORAGE, AK 99507 Engineer's Printed Name JEFFREY A. GARNESS, P.E. Date Engineer's COmments: In conducting this evaluation, GEG, LtD. attempted to provide a thorough, conscientious engineering analysis of the system in accordance with ADEC and MOA DSD Guidelines & Regulations. The reported results described the performance of the system under the conditions encountered at the time of the test, and separation distances measured to readily identifiable features. The operational life of afl wells and septic systems depend on the local soils condition, groundwater levels that may fluctuate during the year, and the water usage of the family being served by the system. These conditions are outside the control of the evaluator of the system. Satisfactory test results do not guarantee future performance of the system, nor do they guarantee that there are no hidden defects or encroachments. GEG, LTD. can therefore not provide any warranty or future estimate dhow long the system will continue to meet the operational requirements of the ADEC or MOA DSD. The content of this report is for the sole benefit of the owner listed above. Any reliance upon or use of this report by any other person or party is not authorized, nor will it confer any legal right whatsoever. DSD SIGNATURE ~"~ Approved for Disapproved. Conditional approval for bedrooms. bedrooms, with the following stipulations: ON-SITE ~ATER AND WATER WASTE · . PROG~M Attachments: COSA Checklist Septic System Advisow Well Flow Advisory Nitrate Advisory (Rev. 11/05) Arsenic Advisow MaintenanCe Agreements Supplemental Engineer's Report utner Original Certificate Date: ~- ~ ~ -// Municipality of Anchorage Development Services Department Building Safety Division On-Site Water & Wastewater Program 4700 Elmore Road P.O. Box 196650 Anchorage, AK 99519-6650 www.muni.org/onsite (907) 343-7904 CERTIFICATE OF ON-SITE SYSTEMS APPROVAL CHECKLIST Legal Description: TERRACE HEIGHTS; BLOCK 1, LOT 19 & 20 Parcel ID: 017-07~--60 WELL DATA Well type PRIVATE Date completed Total depth 221 Date of test Static water level Well production WATER SAMPLE RESULTS: If A, B, or C provide PWSID# N/A Well Log (Y/N) YES 9/11/11 Sanitary seal (Y/N) YES Wires properly protected (Y/N) YES __ft. Cased to 221 ft. Casing height (above ground) 24+ in. FROM WELL LOG AT INSPECTION 9/11/11 NEW WELL 154 ff. ~ft. 4 g.p.m. ~ g.p.m. Coliform O colonies/100 mi. Nitrate 2.73 mg./L. Collected by: Arsenic: ND ug./L. Date of sample: 9/19/11 SEPTIC/HOLDING TANK DATA Tank Type/Material STEEL/PLASTIC Date installed 1250/ Tank size 500 gal. ' Numberof Compartments 2/1 Foundation cleanout (Y/N) YES Date of pumping 9/19/10 ABSORPTION FIELD DATA Date inStalled '. 9//7/2006 Length 40 .ft. Depression over tank (Y/N) NO Pumper I'BELOW EXISTING GRADEI Soil rating (g.p.d./ft~or~ 1.0 Width 15 .ff. Total depth *4.1 6 ft. Date of adequacy test 9/7/2006 Depression over field NO For 4 bedrooms System .type BED Gravel below pipe 0.5 YES YES Fluid depth in absorption field before test 0 in. Elapsed Time: 0 min. Final fluid depth 0 Any rejuvenation treatment (past 12 mo.) (YIN & type) Water added 600 gal. Newdepth 0 in. in. Absorption rate >= 600+ g.p.d. NONE KNOWN If yes, give date - , Eft. absorption area 600 ft2 Monitoring tube YES 8/1/11 Results (Pass/Fail) PASS GEG, Ltd. Cleanouts (Y/N) High water alarm (Y/N) ATCP D. LIFT STATION Date installed 9/7/06 "Pump on" level atTIMER in. X Datum BOTTOM OF TANK * E. SEPARATION DISTANCES SEPARATION DISTANCES FROM WELL ON LOT TO: F= *MAINTENANCE AGREEMENT WITH ATCP Size in gallons "Pump off" level at Cycles tested 100'+ Septic tank/lift station on lot Absorption field on lot 100'+ Public sewer main N/A Sewer/septic service line 25'+ Animal containment areas. 50'+ 5OO in. Manhole/Access (Y/N) YES High water alarm level at 46 Meets alarm & circuit requirements?. YES in. On adjacent lots 100'+ On adjacent lots 100'+ Public sewer manhole/cleanout Holding tank N/A Manure/animal excrete storage areas N/A 100'+ SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK ON LOT TO: Building foundation 5' + Property line 5' + Water main N/A Water service line 10'+ Wells on adjacent lots 100'+ Absorption field Surface water. SEPARATION DISTANCE FROM ABSORPTION FIELD ON LOT TO: 5'+ 100'+ Property line 10'+ Building foundation. 10'+ Water service line 10'+ Surface water 100'+ Curtain drain NONE KNOWN Wells on adjacent lots 100'+ COMMENTS Water main N/A Driveway, parking/vehicle storage 10'+ G. ENGINEER'S CERTIFICATION I certify that I have determined through field inspections and review of Municipal records that the above systems are in conformance with MOA COSA guidelines in effect on this date. Engineer's Printed Name JEFFREY A. GARNESS Date Data of Payment ~/?/-~//// Receipt Number (Rev. 11105) Waiver Fee $ Date of Payment Receipt Number U/IdPER DeARMOUN ROAD ° j o S 8 54'00"E 87.81' S 89'54'00"E'~87.81' , t' ~ ~. 4.0] ~2'x16' CANT ~ 2.6'x6.5' CANT LOT 8 ~ ~~_-~~HO~C~S o LOT 20 o LOT 1 9 0 20,371 s.f. ~ 20,371 s.f. N 89'54'00~ 87.81' N 8n'54'nn~ LOT 7 LOT 1 LOT 2 LOT 3 \ / LOT 18 PLOT PLAN AS BUILT X SCALE 1" -- 40' GRID 2940 ProJecf No. 11-124well Lang &: Associates, inc. 11500 Darvl Avenue, Anchorage, Alaska 99515-5049 (907) 522-6476 Phone Regisfered Land Surveyors (907) 522-4625 Fax kglanglaOalaska.nef / JclanglsOalaska.nef I hereby certify fhaf I have surveyed fhe following desorlbed properly.* LOTS 19 & 20, BLOCK 1, TERRACE HEIGHTS SUBDIVISON Anchoroge Recording Disfrlcf, Alaska, and fhaf fhe Improvemenfs slfuafed fhereon are wlfhin fhe ProPerly Ilnes and do nor encroach onfo fhe properly odJacenf fherefo, fhof no Improvemenfs on fhe properly lying (3dJocenf fherefo encrooch on fhe surveyed premises' and fhaf fhere are no roadwoys, fronsmlsslon lines or ofher vlslble easemenfs on said properly excepf es lndlcafed hereon. Dared fhls fhe %~> Day of ~,~,~'F,~ , 'Z~[ , af Anchoroge, Aloska If is fhe responslbillly of fhe owner fo defermlne fhe exlsfence of any easemenfe, covenanfs, or resfrloflons which do nor appear on fhe recorded subdivision plaf. eP--~O--:;'01 I 02:19 P.01 UNIT # 18 Legal Description: Terrace height BIK 1 LT lg,20 Street Address: 7800 u Deermoud Rd, Owner Name: Sean& Wendy Lincoln Billing Address: PO aox 84~8 Fairbanks, AK 99708 Phone #1 Renters Phone #2 907 699-2336 Wendy's Work Phone #3 907 - 328-9022 Start up date: 9/19/2006 Contract End Date: 9/19/2010 .......... Dates of service 10/3112010 5/29i:~010 ....... ~imer - Off 10 ' 10 t0 ......... Override - On 2 "2 2 ............... Over'ride - Off 5 '5 5 Timer' -'On ....... 2 ...... 2 ...... 2 Pump Run Time ....... 95221 83295 67386 Low Level Count 1374 " 1374 137'3- . High Level Count 78 ~6 64 On9ce clogged (Y/N) n , n n .... Orfice Cleaned (Y/N) y ,y y Phone Line Checked (Y/N) y y y -¥ank'i'~vels Checked (Y/N) ok y y pUmping Needed (Y/N) '"~ n .... No Floats checked (Y/N); ,,' Monitoring Tubesdry.... all dry _ all dry - -Filter Plates Cleaned (Y/h) ' y y' y Pressure Filter Cleaned (Y/N) y y y All Lids secUred (Y/N) y ..... y, y ' Door Hanger_Left. (Y/N) .... y y Notes: System Pumped Oct 2009 Photos: 3329-31 ADVANCED WASTEWATER TREATMENT SYSTEM MAINTENANCE AND REPAIR AGREEMENT MEMORANDUM OF UNDERSTANDING BETWEEN MUNICIPALITY OF ANCHORAGE THIS MEMORANDUM OF UNDERSTANDING made and entered into as of this herein the "OWNER," and the Municipality of Anchorage, herein the "MUNICIPALITY." In consideration of the mutual covenants contained herein, the parties to this Memorandum of Understanding agree as follows: 1. ADVANCED WASTEWATER TREATMENT SYSTEMS. Municipality grants permission to Owner to utilize and operate an Advanced Wastewater Treatment System (AWWTS), described as !-~t.~,oo.t ~'~ ~ located at ~/~-t~££C~('~_.. ]-J'[<o. /~1 Ll~r'~C),Anchorage, Alaska. 2. Def'mitions. A. Alteration. Any change to the design or function of an AWWTS that Includes the installation or removal of any parts, components or pieces not included in the original construction permit and design. Prior to performing any alterations to an AWWTS the owner must obtain a Wastewater Disposal System Construction Permit from the Municipality pursuant to Anchorage Municipal Code (hereinafter, "AMC") 15.65. Certificate of On-Site Systems Approval. A_n approval by the Municipality of existing water and wastewater disposal systems given at the time of property sale and title transfer in accordance with AMC 15.65. These approvals certify that the systems are adequate for the homes that they support and meet the codes that were in place at the time of system construction. C. Damage. Any man-made or naXural change in a system that would inhibit the system from performing as designed. D. Maintenance and Repair. The scheduled and as needed replacement of existing parts, components and pieces of an AWWTS that were included in the original design which would allow the AWWTS to continue to perform as designed. E. Permit (Construction) An On-Site Wastewater Disposal System Construction Permit as defined by AMC 15.65. F. Permit (Operating) An Advanced Wastewater Treatment System Operating Permit. An annual permit, issued by the Municipality, that allows the Owner to operate an AWWTS, upon meeting all the requirements of this agreement, the conditions of Operating Permit, the requirements of the On-Site Wastewater System Construction Permit and all relevant provisions of AMC 15.65 3. Fee. Owner shall pay to Municipality an annual fee of (2) ($ (D .00), payable on or before the issuance of the operating permit and annually thereafter. The annual fee is due on or before the anniversary date of the approval by the Municipality of installed system. 4. Term. The term of this Memorandum of Understanding shall be for the life of the AWWTS. The term begins on the date of approval by the Municipality of the installed system and shall continue while the AWWTS system is in use or operational or until the property is sold or title is transferreA by owner and a new certificate of On-Site approval is issued to the new owner or transferee of the property. 5. Alterations~ InstalLation and Removal of Additional Equipment. Owner agrees not to make any alterations, removal of parts or additions to the AWWTS without a Construction Permit from the Municipality. 6. Maintenance and Repairs. A. Throughout the term of this Memorandum of Understanding, the Owner shall maintain AWWTS in good repair. In addition, it shall be the responsibility of the Owner during the term of this Memorandum of Understanding, and any extensions or renewals thereof, at the owner's sole expense, to pay for any and all: (1) repair(s), (2) maintenance, (3) adjustmem(s), (4) replacement costs, and (5) inspection costs. Further, Owner agrees to comply will all applicable ordinance, laws, regulations, rules and orders for the AWWTS. B. Owner agrees to provide the Municipality a written schedule of routine maintenance and repairs which have been performed on the system pursuant to the terms and conditions contained in the Owner's AWWTS Operating Permit. Th_is schedule shall be submitted to the Municipality annually upon the renewal of the permit. The schedule of maintenance and repair contained in the Owner's AWWTS Operating Permit is: l'-"'~,,~,,~ ~.//~ V¢ ~ r~ C. Owner acknowledges that the fine schedule for failing to maintain and repair an AWWTS are codified in AMC 14.60. D. Owner agrees that only maintenance, repair personnel certified by the Municipality will inspect and make any necessary maintenance, repairs or permitted alterations to the system. E. Owner agrees to grant the Municipality reasonable access to test and inspect the AWWTS upon 24 hours written notice. F. Owner agrees that any sale or transfer of title of the property will not occur without a new Certificate of On-Site Systems Approval. G. Owner agrees that the relevant provisions of the standard specification guidebook for AWWTS is the governing professional guidelines for the construction, maintenance and repair of the Owner's AWWTS. 7. Nonwaiver. The failure of either party at any time to enforce a provision of this Memorandum of Understanding shall in no way constitute a waiver of the provisions, nor in any way effect the validity of the Memorandum of Understanding or any part hereof, or the right of such party thereafter to enforce each and every provision hereof. 8. Amendment. A. This Memorandum of Understanding shall only be amended, modified or changed by a writing, executed by authorized representatives of the parties, with the same formality of this Memorandum of Understanding was executed and such writing shall be attached to this Memorandum of Understanding as an amendment. B. For the purposes of any amendment modification or change to the terms and conditions of this contract, the only authorized representatives of the parties are: Owner: Anchorage: Purchasing Qfficer C. Any attempt to amend, modify, or change this contract by either an unauthorized representative or unauthorized means shall be void. 9. Jurisdiction: Choice of Law. Any civil action arising from this Memorandum of Understanding shall be brought in the Superior Court for the Third Judicial District of the State of Alaska at Anchorage. The laws of the State of Alaska shall govern the rights and obligations of the parties under this Memorandum of Understanding. 10. SeverabiliW. Any provisions of this Memorandum of Understanding decreed invalid by a court of competent jurisdiction shall not invalidate the remaining provisions of the Memorandum of Understanding. OWNER: MUNICIPALITY: By: Title: Date: STATE OF ALASKA THIRD JUDICIAL DISTRICT The foregoing insmunent was acknowledged before me this [¢;"day of.. ;~,:~-17~ ~-.~.~-' , 20'~ ~, , by .~,~'~q.\~ ....... ~c.,~.ii%C._ ,, ......... NOTARY ~BI~iC FOI~ ALASKA My Commission expires: State of Alaska NOTARY PUBLIC Ashlee ~aVigne My Corem Expires .4~:~ ! ~ !~'~ Municipality of Anchorage · Development Services Department Building Safety Division. On-Site Water & Wastewater Program 4700 Bragaw Street P.O. Box 196650 Anchorage, AK 99519-6650 www.munl.org/onsite (907) 343-7904 CERTIFICATE OF ON-SITE SYSTEHS ,A, PPROVAL FOR ,5, SINGLE FAHILY DWELLING GENERAL INFORMATION cos^# Expiration Date: /,~,,. - ~ ~ - 0 ~-, Complete legal description Location (site address) Current Property owner(s) Mailing address Lending agency Mailing address TERRACE HEIGHTS SUBDIVISION; LOT 19 & 20, BLOCK 1, 7800 UPPER DEARMOUN ROAD * ANCHORAGE, AK 99516 JOHN & GAIL HOWE Day phone 345-6110 P.O. BOX 110277 * ANCHORAGE~ AK 99511 Day phone R~t~Agent CYNOI[PARTCH w,/ PRUDENTIAL J.W. Dayphone ~l[~~gaddress .3801 CENTER POINT DRIVE*ANCHORAGE, AK 9950.3 Un~ess otherwise requested, COSA will be held by DSD for pickup. 2. NUMBER OF BEDROOMS: 4 762-3189 3. TYPE OF WATER SUPPLY: Individual Well Individual Water Storage Community Class Well Public Water System TYPE OF WASTEWATER DISPOSAL: Individual On-site ~ Individual Holding tank Community On-site E]~ Public Sewer The Municipality of Anchorage Development ~ervicas Departmen~SDTl~ues C(~rtific~tes of Ot~Site-S?stei'ns Approval (COSA) based only upon the representations given in paragraph 4 by an independent professional civil engineer registered in the State of Alaska. Certificates of On-Site Systems Approval are required for the transfer of title (except between spouses) for properties served by a single-family on-site wastewater disposal and/or water supply system. DSD also issues COSAs upon request to homeowners. Certificates of On-Site Systems Approval are valid for 90 days from the date of issue for properties served by a private or Class C well and may be reissued with new water samples. (Certificates may be reissued for a period of up to one year with valid water samples.) Certificates are valid for one year for properties served by Class A or B wells or a public water system. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. 4. STATEMENT OF INSPECTION BY ENGINEER AS certified by my seal affixed hereto and as of the validation date shown below, I verify that my · investigation, based on procedures outlined in the Certificate of On-Site Systems Approval Guidelines for this application, sho~vs th~ lhe 'on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate for lhe I~um, b..er o.f bedrooms and type of structure indicated herein. I further verify that based on the information' obtait~&d from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation. Name of Firm GARNESS ENGINEERING GROUP, Ltd. Address 3701 E. TUDOR ROAD, SUITE 101 * ANCHORAGE, AK 99507 Engineer's Printed Name JEFFREY A. GARNESS, P.E. Phone 337-6179 Date Engineer's Comments: In conducting this evaluation, GEG, LtD. attempted to provide a thorough, conscientious engineering analysis of the system in accordance with ADEC and MOA DSD Guidelines & Regutations. Tho repealed results dosc~bed the perfo~rnance of the system under the conditions encountered at the time of the test, and separetico distances measured to readily identifiable features. The q~erationat life of all wells and septic systems depend on the IGC. at soils condition, groundwater levels that may £uctuate during the year, and the water usage of the family being served by the system. These conditions ere outside the control of the evaluator of the system. Satisfactory test results do not guarantee future performance of the system, nor do they guarantee that there ere no hidden defects ~ encroachments. GEG, LTD. can therefore ncr provide any warranty or future estimate of how long the system will continue to meet the operational requirements of the ADEC or MOA DSD. The content of this report is for the sole benefit of the owner listed above. Any reliance upon or use of this report by any other person or pady is not authorized, nor will it confer any legal dght whatsoever. 5. DSD SIGNATURE II Approved for '7' bedrooms. Disapproved. Conditional approval for .~ Attachments: COSAChecldist Septic System Advisory Well Flow Advisory Nitrate Advisory bedrooms, with the fllowing stipulations: Arsenic Advisory Maintenance Agreements Supplemental Engineer's Reort Other ~~ Original Certificate Date: Municipality of Anchorage Development Services Department Bu~d~lg Safely OMsk3n On-Site Water & Wastewater Program 4700 Bragaw Slreet P.O. Box 196650 Anctx~rage, AK 99519-665O www.munLarg/onsJte ¢g07) 343-70O4 CERTIFICATE OF 0N-SITE SYSTEMS APPROVAL CHECKLIST LegstDescdpfie~: ii. RACE HEIGHTS S/Di LOT 19 & 20~ BLOCK. 1~ ParcellD: A. WELL DATA *PER 8/21/1975 REQUEST FOR APPROVAL. Well ~ PRIVATE: If A, B, or C provide PW'SID~ N/A Wall Log (Y/N) NO Datecompleted ~ 1975 Sanitary ,,est (Y/N) YES Wires propedy protected (Y/N) YES Totaldepth *190 ft. Casedtu f0+ ft. Casing height (above gmund) 12+ in. FROM WELL LOG AT INSPECTION Date of test 6/29/2006 Static--r., ~.~.~~'~ft. ,10 ft. Well pro~uclion .- g.p.m. 6.0 g.p.m. WATER SAMPLE RESULTS: Coliform O colonEts/lO0 mi. Amenic~ Nn ugJt.. Nilmte ~ mg./L. Other bacteria @ colonies/lO0 mi. Date ofsampEt: 6/29/2006 Collected by: GEG, Ltd SEPllC/HOLDINO TANK DATA Tank Type/Matedst STEEL/PLASTIC 1250/ Tanksize 500 gal. Number of Comperlmenta 2/1 FoundatJon deanout (Y/N) YES Depression over tank (Y/N) NO Date of pumping NEW Pumper Date installed 9/7/2006 Cleanoute (Y/N) YES High water alarm (Y/N) YES C. ABSORPllON FIELD DATA ~ Date installed 9/7/2ooe Soil rating ~or fl~/bdrm) 1.0 System type BED Length 40 fl. Width 15 ft. Gravel below pipe 0.5 Total depth °3.0 .ft. Eft. absorption area 600 ft= Monltedng tube YES Depression over field Date of adequacy test NEW Results (Pass/Fall) - For 4. NO bedrooms Fluid depth in abeorptlon fleet before test - in. Water added - gal, Now depm - in. Elapsed Time: - min. Final fluid depth - in. Abeorptton rate >= - g.p.d. Any rejuvenation treatment (past 12 mo.) (y/N & type) - If yes, give data - O. UFT STATION Date installed 9/7/2006 "Pump on" level at TIMERIn. Datum BOTTOM OF TANK E. SEPARATION DISTANCES Size in gallons 500 "Pump off" level at ~M_~_~in. Cycles tested NEW SEPARATION DISTANCES FROM WELL ON LOT TO: Septic tenk/llff station on lot 100'-t' Absorption field on lot 100'+ Public sewer main N//A Sewer/~epflc service line 25'+ Animal containment areas 50'+ Manholel.~_ _~_ (Y/N) YES High water alarm level at 46 in. Meets alarm & circuit requirements?. YES On edJacent lots 100'+ On edjacem lots 100'+ Public sewer manhole/cleanout Holding tank N/A Manure/animal excrete storage ames 100'+ SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK ON LOT TO: Building foundation 5'+ Property line 5'+ Water main N/A Water service line 10'+ Wells on adjacent lots 100'+ SEPARATION DISTANCE FROM ABSORPTION FIELD ON LOT TO:. Property line 10'+ Building foundation 10'+ Water sewice line 10'+ Surface water 100'+ Curtsin drain NONE KNOWN Wells on adjacent lots 100'+ At)so~tlon field ~'+ Sudace water. 100'+ Water main N/A Driveway, parking/vehicle storage 10'+ F. COMMENTS G. ENGINEER~ CER~FICA~ON / cerefy tlmt I have determined through field/nspe~ end re~4ew of Municipal records Itmt the ebove ~ystems ere in conformance with MOA COSA guidelines in effect on this date. Engineers Pd0ted Name JEFFREY A. GARNESS Date ~/ Waiver Fee $ Date of Payment Receipt Number LOT 8 UPPER DeARIdOUN ROAD S 89'54'O0'E87.81'-'ITS.7' S 8g'54'OO'E 87.81' LOT 18 LOT 7 LOT 20 20,~71 a.f. N 89'54'00'W 87.81' LOT 1 LOT 20.371 N 8g'54'OO'W 87.81' LOT 2 PLOT PLAN AS BUILT X SCAL~ 1" - 40' GRID I 2940 Project No. 06-154 'Lang & Associates, inc. (g07)522-6476 Phone Reglstered Land Surveyors (go7) s22-~25 kglangle~,alaeka.nat / Jclangl~alaska.nat I hereby cer~fy that I have lum'eyed the following deeer~bed properly:. LOTS 19 ac 20, BLOCK 1, TERRACE HEIGHTS SUBDIViSON Anchorage Reeordlng Dl~frlct, Alaeka, and that the Improvements Iltuated thereon are within the properly Ilne~ and do not encroooh onto the properly adjacent therato, that no Improvement~ on tho properly lylng adJooent therato enoroaoh on the euweyed premleee and that there are no roadways, traneml$$1on Ilnee or other ~letble ea~emeata on ~ald properly ex~ept a~ Indloated hereon. Dated thio the ~z>~ Day of ~ 'boC~ , at Anohorage, Ala=ka It le the reeponelblllfy of the owner to defermlne the exl~fen~e of any eo~emenf~, covenanfa, or roefrlatlons which do not appear on the recorded eubdlvlelon plat. 11500 Daryl Avenue, Anchorage, Alaeka 99515-~049