Loading...
HomeMy WebLinkAboutSUSITNA VIEW ESTATES BLK 1 LT 10S usitna View Estates Block 1 Lot 10 #020-091-17 MOA has confirmed that the on-site systems have not been installed. Altu icipality of Anchorage 1!0.IAI\1!Ai(:i(1•.lnchum;:C. Alaska !M6i1!Idi(Ci(1•;i(N) Hlnu,ri R.Kel ( Illicc: 0171 3;3.9U)i • F'am (!K)7) 343 R3(M) litildhimmumimrr Mayor 3lark Begich Development Scritices Department 19 November 2008 Michael R Dana Sharrock 10101 ]Hillside Drive Anchorage, AK 99516 Subject: Expired On -Site Water and/or Wastewater Permit Permit Number: SW070322 Legal Description: Susitna View Estates Block 1 Lot 10 Dear Michael R Dana Sharrock: Dent CoQ Sr,� y�v n s Department An On -Site Water/Wastewater Permit, number SW070322 issued by this office for a single-family system, will expire on 12 December 08. Permits are valid for 365 calendar days from date of issue. If this was a well permit and the well has been drilled, a well log and a pump install log must be sent to this office for documentation of the installation and to close the permit. If this permit was for a wastewater disposal system, an original as -built inspection report must be sent to this office for review, approval and documentation. This as -built inspection report must be signed by the licensed Professional Engineer who inspected the installation of the system. As -built inspection reports are required to be submitted within 30 days of the completion of the system. If no system was installed under this permit, and you are still planning to install a well or wastewater disposal system, a new permit must be obtained from this office. A one-time renewal fee for a second year may be issued for a $115.00 if the renewal application is received on or before the expiration date of the original permit. When applying for a new permit, the fees are $460.00 for a wastewater permit and $175.00 for a well permit. If you have any questions, please call this office at 343-7904. Sincerely, Kaa leen Maricle Permit Clerk II On -Site Water and Wastewater Program Enc: Copy of permit Community, Security, Prosperity MUNICIPALITY OF ANCHORA GE Development Services Department On -Site Water & Wastewater Program 4700 South Bragaw Street P.O. Box 196650, Anchorage, AK 99519-6650 (907) 343-7904 ON-SITE WASTEWATER DISPOSAL SYSTEM / WATER SUPPLY PERMIT —Initial 2�rtt,,�k Permit Number: SW070322 Date Issued: Dec 13, 2007 Expiration Date: Dec 12, 2008 Parcel ID: 020-091-17 Legal Description: SUSITNA VIEW ESTATES BLOCK 1 LOT 10 Design Engineer: 0014 ANDERSON ENGINEERING Site Address: 16800 FEODOSIA DRIVE Owner Name: MICHAEL & DANA SHARROCK Lot Size: 25880 SO. FT. Owner Address: 10101 HILLSIDE DRIVE Total Bedrooms: 4 Permit Bedrooms: 4 ANCHORAGE. AK 99516 - This permit Is for the construction of: 0 Disposal Field ❑✓ Septic Tank ❑ Holding Tank ❑ Privy Private Well ❑ Water Storage All construction must be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal Code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72 ) and Drinking Water Regulations (18AAC80 ). 3, The engineer must notify DSD at least 2 hours prior to each inspection. Provide notification by calling (907) 343-7904 ( 24 hours). ( Not required for a Water Supply Permit only). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must be either: A. Open and closed on the same day. B. Covered, sealed, and heated to prevent freezing. Received By Date: �Q L / Issued By: � Date: ' aI wva, Municipality of Anchorage Development Services Department Building Safety Division On -Site Water and Wastewater Program 4700 Bragaw Street P.O. Box 196650 Anchorage, Alaska 99519.6650 www.muni.org/onsite (907) 343-7904 ON-SITE SEWER/WELL PERMIT APPLICATION FOR A SINGLE FAMILY DWELLING Parcel I.D. _ OCX) – bq I- I 'T Property owner(s) r l'Yi d 471)tanA Sb V YVY_Day phone Mailing address _I n I b I Q f 2 i sc/W 'Dr. Zip Code Site address Ito%M _ _ Ef n' `►Aui, e Zip Code Legal description (Sub'd., Block & Lot) 'SUSc.' M V le to GSA 11 LID Legal description (Township, Range & Section) Lot Size .,-CJS Sq. Ft. Number of Bedrooms 4 THIS APPLICATION IS FOR (® all that apply): Absorption Field Septic Tank �] Holding Tank ❑ Privy Private Well Water Storage I certify that the above information is Single Family Dwelling and is in acct 1)( lu_^_ (Signature of property owner or ■ ■ THIS APPLICATION IS AN: Initial ❑ Upgrade ❑ Renewal . I further certify that this application is being made for a with applicable Municipal Codes. Permit/Rush Fees: — Waiver Fees: Date of Payment: /0// t 497 Date of Payment: Receipt Number. AE t7 Receipt Number. (Rev. 11/05) MUNICIPALITY OF ANCHORAGE Development Services Department On -Site Water& Wastewater Program 4700 South Bragaw Street P.O. Box 196650, Anchorage, AK 99519-6650 (907) 343-7904 ONSITE WASTEWATER DISPOSAL SYSTEM / WATER SUPPLY PERMIT Initial Permit Number: SWO60337 Date Issued: Oct 17, 2006 Expiration Date: Oct 17, 2007 Parcel ID: 020-091-17 Legal Description: SUSITNA VIEW ESTATES BLOCK 1 LOT 10 Design Engineer: 0014 ANDERSON ENGINEERING Site Address: 16800 FEODOSIA DRIVE Owner Name: MICHAEL & DANA SHARROCK Lot Size: 25880 SO. FT. Owner Address: 10101 HILLSIDE DRIVE Total Bedrooms: 4 Permit Bedrooms: 4 ANCHORAGE, AK 99516 - This permit is for the construction of: ❑✓ Disposal Field ❑✓ Septic Tank ❑ Holding Tank ❑ Privy ❑✓ Private Well ❑ Water Storage All construction must be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal Code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations ( 18AAC80 ). 3. The engineer must notify DSD at least 2 hours prior to each inspection. Provide notification by calling (907) 343-7904 (24 hours). ( Not required for a Water Supply Permit only). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must be either: A. Open and closed on the same day. B. Covered, sealed, and heated to prevent freezing. Received By: Date: 161() 0 ANDERSON ENGINEERING P.O. BOX 240773 ANCHORAGE, AK 99524 522-7773 677-7766 FAX MEMORANDUM DATE: October 3, 2006 TO: Jeff Poet FROM: Mike Anderson, P.E. SUBJECT: Lot 10, Block 1, Susitna View Estates Subdivision Well and Septic System Permit We recently cross sectioned the slopes fronting the proposed absorption trench on Lot 10, Block 1, Susitna View Estates Subdivision. We then plotted the 25% slope from 2' above the distribution line to its daylight point on the slope. The distance on Section No. 1 is slightly more than 35'. At Section No. 2 the 25% slope does not daylight. The results of our survey and the cross section of the slope is shown on the attached drawings. In addition we are submitting a request for a waiver to allow the separation distance to a slope greater than 25% to be reduced to 35'. Please let me know if you have further questions. WAIVER FEE: PAYMENT DATE: 2o %3 - RECEIPT#: ANDERSON ENGINEERING P.O. BOX 240773 ANCHORAGE, AK 99524 -7773 677-7766 (F October 3, 2006 Municipality of Anchorage Development Services Department On -Site Water and Wastewater Program 4700 South Bragaw Street Anchorage, AK 99519-6650 Subject: Lot 10, Block 1, Susitna View Estates Subdivision Absorption Trench to Slope Waiver Dear Onsite Services Engineer: Lot 10, Block 1, Susitna View Estates Subdivision has limited area for construction of a septic system due to steep slopes and the presence of a stream to the east. We have located an area with acceptable soils, but it is situated slightly more than 35' from a break in grade greater than 25%. We are therefore applying for a waiver allowing placement of the absorption trench at this location. We have designed an Advantex Treatment System f requirements for the absorption trench. The use of this possibility of contaminated effluent surfacing on the face recommend a waiver be issued allowing placement of the 35' of a slope greater than 25%. Sincerely, Michael E. Anderson, P.E. 49th MICHAEL E. ANDERSON or the lot to limit the area system nearly eliminates the of the slope. We therefore new absorption trench within Ln O co O U! O O N J O N N O N C Ci a O U) —� c) oD (A --i m m o � O L D o D CO m --i N 0U UO n c m o cn V: CO O O z Q� CT J N O cLI—TH2 Vm O N O co co O O N J O J N O N N C,^ p`ss V / CA o ' ^ y / 0poD N m , m o 0 D P. Z C/) N W --i N0 Cl)n mac o z,CO 0 U) w 0 0 z Ln J O V N ' N 00 O TMz ANDERSON ENGINEERING P.O. BOX 240773 ANCHORAGE, AK 99524 September 18, 2006 Municipality of Anchorage Development Services Department On -Site Water and Wastewater Program 4700 South Bragaw Street Anchorage, AK 99519-6650 Subject: Lot 10, Block 1, Susitna View Estates Subdivision Septic System Design and Permit Application Impacts to Adjacent Properties Dear Onsite Services Engineer. The owner of Lot 10, Block 1, Susitna View Estates Subdivision intends to construct a four-bedroom home on the lot. We are therefore requesting a permit be issued for a well and septic system to serve the new home. The available area for the septic system is limited due to the location of wells in the area, step slopes and the stream to the west making it difficult to place a conventional septic system. We have therefore decided to place an Advantex Treatment System on the lot to provide the most effective treatment of the septic effluent prior to discharge into the surrounding soil strata. The location of the absorption system is shown on the attached Site Plan. Drainage patterns are also shown on the plan and will not be modified as a result of the proposed construction. The test holes placed on this lot revealed silty gravel with some sand. The percolation rate in the materials encountered was close to 60 minutes per inch. Groundwater seeps were found between 15' and 16' during the excavation but were noted at 12' below the surface during monitoring. Our design provides for the bottom of the absorption trench to be as shallow as possible. We are therefore proposing to place a four-bedroom Advantex Treatriient System. The absorption trench will be 60' long x 5' wide x 4' effective depth. The distribution line in the trench will be placed at 2' below the existing ground level. Total depth of the trench will be 6' below the surface. 3' of fill will be placed above the trenches and 4' over the septic tank to meet Municipal Code and prevent freezing. The ground surface of the lot slopes at 30% to the west from the Feodosia Drive, but becomes shallower near the location of the primary absorption trench. The trench will be constructed parallel with the slope as much as possible in conformance with Municipal requirements. All components of the new septic system will be constructed a minimum of 100' from any surface water and 100' from the well proposed for this lot. Lot 10, Block 1, Susitna View Estates Subdivision September 18, 2006 Page Two No conflicts exist between the proposed well and septic system and those in the area. If the system is constructed in accordance with our design the following statements apply: The system, if constructed as designed, will have no adverse impact on the wells in the area or those to be constructed in the future. 2. The system, if constructed as designed, will have no adverse impact on existing septic systems in the area or those to be constructed in the future. 3. The system, if constructed as designed, will have no adverse impact on reserve space, either surface or subsurface, on any lots located in the area. 4. The system, if constructed as designed, will have no adverse impact on drainage patterns in the area. The current drainage pattern will be maintained. Sincerely, Michael E. Anderson, P.E. Attachments 49;_ 4C`IAC E. AN:ERSCN 0 1+4rf ❑ C3 IM6� Yw• f.rr. r � r � f i � f 49th AREA MAP �'& i1tlCJUEL•L N10ERSai I SCALE V - 30' ����,iy•.._ No. CE-�3mV:� N WONVE 130.']• 10• ML ESR. f I n i� I SSS® I 43 S• C ® I N U) la • • I v Z D 11A of 9 Igo 3 a C N j Im Q 13 r D �7-� d m m o r1 1- 1 N I In 1 ,nm Dm N T r 0 m m r U) U) D JU) Z CC) I � I C I I U) I o I Z I A� S •••�•a `5�•••.n P,Ot. 3Nap03�� S SQj off IN MUNICIPALITY OF ANCHORAGE DEVELOPMENT SERVICES DEPARTMENT 4700 BRAGAW STREET ANCHORAGE, AK 99519-6650 SOILS LOG - PERCOLATION TEST LEGAL DESCRIPTION: Lot 10 Block 1. Susitna View Estates Sub. PERFORMED FOR: Dana Sharrock DATE: 7/17/2006 PROJECI'No.: PARCELID#: TECHNICIAN: A. Harala Drrm TEST MOLE # 1 (fCCI) 1 2 3 :. 4 •. 5 .t. .. �: 6 r:..'.;.'. 7 .+..i;:�.. 8 9 10 ;. ..�. 12 A 13 ::.. ••,, 14 '� 15 ' � i�;=• 17 1 Grass/Organics Silty Gravel GM O 1 61 SITE P1 AN SEE SITE PLAN GROUND WATER ENCOUNTERED' 15' p� IFYES®WIIATDEFTn 15•y to 25,% Very Dense DEPTH®MONITORING DATE OFMONITORING. 9 1S OB Groundwater Seeps ® 15' - Mm DATE READING NUNt IME (MINUTES) NET TIME (MINUTES) DEPTH To JNET WATER (INCHES) DROP (INCHES 7/30/06 TEST HOLE PRESOAKED PRIOR TO TESTING: 1 7:19 7.38" CIIARGE 2 7:49 30 8.13" .35" 3 7:50 7.5" RECHARGE 4 8:20 30 8.06" .56" 5 8:21 6.75" RECIIARGE 6 8:51 30 6.25" .5" PERCOLATION PATEL —60(MIN/INCII) PERC. HOLE DIA. 6 (INCHES) TEST RUN BETWEEN.--J—FT. and_fl_FT. COMMENTS: TEST HOLE PRE SOAKED PRIOR TO TEST. TEST PERFORMED BY ANDERSON ENGINEERING. 1, MICHAEL E. ANDERSON CERTIFY THAT THIS TEST WAS PERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPLE GUIDELINES IN EFFECT ON THIS DATE, 9/182006 MUNICIPALITY OF ANCHORAGE DEVELOPMENT SERVICES DEPARTMENT 4700 BRAGAW STREET ANCHORAGE, AK 99519-6650 I SOILS LOG - PERCOLATION TEST I LEGAL DESCRIPTION: Lot 10 Block 1. Susitna View Estates Sub. PERFORMED FOR: Dana Sharrock DATE: 7/17/2006 PROJECT No.: PARCEL IDN: TECHNICIAN: A. Harala DErnl TEST HOLE # 2 MCI) 1 2 3 •• .4 4 5 6 7 8 9 •� ''r 10 r' �•aA •1 13 14 15i�; 16 17 18 ' 19 Grass/Organics Silty Gravel GM SITE PLAN SEE SITE PLAN GROUNDWATER ENCOUNTERED' IFYFS®WIIATDEmn 15% to 25% Very Dense DF.m1®MONITORING + DATE OF MONITORING.9 135 OB Groundwater Seeps ® 15' BOH 18' DATE READING tUMOUSNSE NET TIMEJ (MINUTES) DEPTH To WATER (INCHES) N�T DROP (INCHES IME (MINUTES) 7/30/06 TEST HOLE PRESOAKED PRIOR TO TESTING: 1 7:41 5.13" 1 CIIARGE 2 8:21 30 5.75" .62" 3 8:22 5.06" RECIIARGr: 4 8:52 30 5.62" .56" 5 8:53 5.25" RECHARGE 6 9:23 30 4.75" .5" PERCOLATION RATE 60 (MIN/INCII) PERC. IIOLE DIA• 6 (INCHES) TEST RUN BETWEEN:__FT. and 6 FT. COMMENTS: TEST HOLE PRE SOAKED PRIOR To TEST. TEST PERFORMED BY ANDERSON ENGINEERING. 1, MICHAEL E. ANDERSON CERTIFY THAT TI IIS TEST WAS PERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPLE GUIDELINES IN EFFECT ON THIS DATE* 9/182006 ONSITE WASTEWATER DISPOSAL SYSTEM CONSTRUCTION AND MATERIAL SPECIFICATIONS SUBJECT: LOT 10, BLOCK 1, SUSITNA VIEW ESTATES SUBDIVISION GENERAL: 1. The scope of this project includes the procurement and placement of a new Four Bedroom Advantex Treatment System with an AX -20 -Mode 1a 40x94 Pod to serve the new home on the lot. System will be placed at the location shown on the Site Plan. The new septic system also includes the construction of a new 60' long X 5' wide X 4' effective depth absorption trench at the location also shown on the Site Plan. The distribution line in the trench will be placed 2' below the existing ground surface. The total depth of the trench will be 6' below the surface. The new system must be placed a minimum of 100' from the proposed well on the lot and those on adjacent lots and 100' from any surface water located on or near or on the lot. 2. Construction shall be in accordance with the approved site plan, design drawings, Municipal Permit with any special provisions or conditions, and all applicable State and Municipal Wastewater Disposal Regulations. 3. The Contractor shall be responsible for obtaining all underground utility locates and for the layout of the septic system and verification of the location of all lot lines. 4. Unless specifically agreed otherwise, the contractor shall be responsible for final grading areas subsequently depressed from soil settling. Property owner shall be responsible for revegetation of affected areas unless specifically agreed otherwise. 5. Contractors installing wastewater disposal systems must be certified by the Municipal Department of Health and Human Services for system installations. Owners installing their own systems must receive prior approval from D.H.H.S. before beginning system installation. SEPTIC TANK INSTALLATION 1. The Advantex Treatment System must be installed in conformance with specifications and regulations furnished by the manufacturer, Anchorage Tank and Orenco Systems Incorporated. No variances from the manufacturer's specifications will be allowed without permission from the manufacturer and Municipal representatives. 2. A septic tank is to be constructed by a certified septic tank manufacturer. Construction shall include two 4" cleanouts for pumping access. Lot 10, Block 1, Susitna View Estates September 18, 2006 Page 2 of 4 3. The septic tank shall be sufficiently bedded to prevent settling or shifting of the tank. 4. All standpipes on the septic tank shall extend a minimum of 12 inches above final grade. 5. Tanks installed without 4' of cover shall have a minimum of 2" of direct burial insulation. 6. A foundation cleanout shall be installed one to four feet from the building foundation. Two cleanouts are required between the tank and the drainfield. 7. Final grading over the tank shall be such that a positive slope exists away from the septic tank. DRAINFIELD CONSTRUCTION: 1. The drainfield shall be constructed to the dimensions shown on the design. The bottom of the bed shall be within 2" of level. 2. Distribution piping must be placed level with perforations down atop a level bed of drainfield rock. Rock should then be placed over the pipe to provide a minimum of 2" of cover. 3. A silt barrier or geotextile fabric must be placed between the drainfield rock and the natural soil backfill. 4. Monitor tubes must be 4" in diameter and installed at the locations shown on the design. The portion below ground must be perforated. 5. Contractor shall verify the septic tank and drainfield are a minimum 100' away from any private water wells in the area, 150' from a Class "C" Well or 200' from any community well. 6. Direct bury insulation must be placed over the distribution system if less than 3' of backfill depth is available. Finish grade over the trench must be mounded to prevent settlement or depressions. 7. Grade area surrounding the absorption trench to drain away. 8. A minimum 2' of accepting soil is required below the drainfield rock for a 5' wide trench. Contractor shall verify this condition prior to placement of the rock. All pockets of unacceptable materials must be removed and replaced. Lot 10, Block 1, Susitna View Estates September 18, 2006 Page 3 of 4 MATERIAL SPECIFICATIONS: 1. Septic tanks must be constructed by a municipally approved septic tank manufacturer. 2. The following pipe materials are approved for use in septic system installations in the Municipality of Anchorage: Cast Iron (perforated and solid), ASTM D3034 or P.V.C. (perforated and solid), ASTM F810 or H.D.P.E. (perforated, but not solid) and ASTM D2662 or A.B.S. (perforated and solid). 3. Insulation shall be at least 2" thick extruded direct burial polystyrene (Dow Chemical Co. Styrofoam HI or equal). 4. Septic tank inlets and outlets shall be fitted with watertight couplings (Caulder, Femco, or equal). 5. A permeable geotextile fabric (Typar, Mirafi or equal) must be installed between the final drain rock layer and the native soil layer. 6. All drain rock shall be .5' to 2.5" in diameter with less than 3% passing the #200 sieve. SAND GRADATION: 1. Sand used to level the new absorption bed must have the following gradation: 50% Passed the No. 4 Sieve 2% Passed the No. 100 Sieve 1% Passed the No. 200 Sieve 2. The sand source must be approved prior to use. INSPECTIONS: Municipal Ordinance requires a minimum of two inspections. These inspections must be conducted under the supervision of a professional engineer registered in the State of Alaska. The first inspection must be conducted after the excavation of trenches, beds or pits and before the installation of any gravel. A septic tank may be set in place, but may not be backfilled. The second inspection must be conducted after the placement of the geotextile fabric, gravel, distribution piping, standpipes, cleanouts and insulation. No backfill should be in place at the time of inspection. Lot 10, Block 1, Susitna View Estates September 18, 2006 Page 4 of 4 Contractor shall provide a copy of all field survey layout and construction notes for use in preparing the certified as -built of the completed system. Municipality of Anchorage Development Services Department Building Safety Division On-site Water and Wastewater Program 4700 Bragaw Street P.O. Box 196650 Anchorage, Alaska 99519-6650 www.muni.org/onsite (907) 343-7904 ON-SITE SEWERMELL PERMIT APPLICATION FOR A SINGLE FAMILY DWELLING Parcel I.D. 020-091-17 Property owner(s) Michael and Dana Sharrock Day phone 884-3457 Mailing address 10101 Hillside Drive Anchorage, AK Zip Code 99516 Site address 16800 Feodosia Drive Anchorage, AK Zip Code 99516 Legal description (Sub'd., Block & Lot) Lot 10 Block 1 Susitna View Estates Subdivision Legal description (Township, Range & Section) Lot Size 25,880 Sq. Ft. THIS APPLICATION IS FOR (❑ all that apply): Absorption Field M. Septic Tank 0 Holding Tank ❑ Privy ❑ Private Well (] Water Storage ❑ Number of Bedrooms Four (4) THIS APPLICATION IS AN: Initial El Upgrade ❑ Renewal ❑ I certify that the above information is correct. I further certify that this application is being made for a Single Family Dwelling and is in accordance with applicable Municipal Codes. (Signature of property owner or authorized agent) Receipt Number. Receipt Number. (Rev. 11/05) OPINION OF COMPLIANCE ANCHORAGE GENERAL PERMIT 93-10N File Number: POA -2006-1424 Municipal Reference: Little Survival Creek 06-A Permittee: Mary Kron Expiration Date: September 6, 2008 The permittee will perform work In waters of the U.S. (wetlands) in accordance with the terms and conditions of the Anchorage General Permit, as specified below: Project Location: 16800 Fedosia, Anchorage, Alaska. Lot 10, Block 1, Susitna View Estates. Map M 106 Wetland Unit #: 85A Work Description: s.f. home construction, with driveway, well and septic system. Wetlands fill amounts: 600 Cubic Yards, 0.1 Acres All work will be performed in accordance with the attached plan, sheets 1 of 1, dated August 14,2006; updated 8131106. Anchorage General Permit Conditions: General conditions: 1. Water Quality Certification. You must comply with all conditions specified as part of the Alaska Department of Environmental Conservation Water Quality Certification, which is part of these General Permits (GPs). 2. Historic and Archaeological Sites. These GPs do not authorize activities, Including the use of material borrow sites, In or that adversely affect known historic properties listed or potentially eligible for the National Register of Historic Places, nor any such sites listed or found to be potentially eligible in the future. The permittee shall stop work when cultural resources are Inadvertently discovered during the course of work and notify the Corps. The Corps will enter Into consultation with the Alaska State Historic Preservation Office to determine If historic properties will be affected by the permitted work. Work shall resume after cultural resources have been evaluated pursuant to Section 106 of the National Historic Preservation AcL 3. Inspections. You must permit the District Engineer, or his designated representatives, to Inspect the authorized activity at any time deemed necessary to ensure that it Is being, or has been accomplished In accordance with the terms and conditions of these GPs. 4. Maintenance. You must maintain the authorized activity In good state, and in conformance with the terms and conditions of these GPs. You are not relieved of this requirement even if you abandon the authorized activity, although you may make a good faith or legal transfer to a third party, as described below. Should you wish to cease to maintain the activity or abandon it without a good faith transfer, you must obtain a modification of the GP authorization from the Corps Regulatory Branch either directly, or through Municipal Planning Staff. Such modification may require restoration of the area. 6. Sate or Transfer of Property. If you sell or transfer the property associated with the authorized activity, you must obtain the signature of the new property owner as the transferee In the space provided on this document and submit a copy of that page to the Municipal Planning Department and/or Corps Regulatory Branch, along with appropriate documentation of the transaction. You Mary Kron POA -2006-1424 Little Survival Creek 06-A must submit this Information within 30 days of the property transfer, to validate transfer of the GP authorization to the new party. Project site restrictions and design criteria: 1. Construction Timing Window. To protect nesting migratory birds, as required by the Migratory Bird Treaty Act, no work p.e., Gearing, grading, excavation• stockpiling, or placing of fill) may occur on the site between April 15 and July 15, unless: a) the site is sufficiently disturbed prior to April 15 to eliminate suitable nesting habitat: and, b) construction activity will occur continuously through June 15. Note., Clearing orotherdisturbanceofthe site prfortoApril 15may require Corps orother authorization. 2. Local Flooding. The project shall Incorporate design and construction featureshnethods necessary to ensure that the proposed project will not cause flooding of adjacent properties or public Infrastructure. 3. Stormwater Functions. The applicant shall demonstrate that the project plans Include sufficient measures to effectively replace the she's pre -project stormwater retention and filtration capacity. The measures shall be sufficient to approximate zero net runoff increase for storms with 2 -year frequency and no more than two times net runoff Increase for storms with a 10 -year frequency, including flows from subdrains. Verification that the project's stormwater design meets this criterion must be obtained from the Municipal Wetland Management Section or its designee, and must be Included with the GP application package. Project -specific conditions: 1. Time Umit GP authorization of this project expires on: September 6, 2008. If you need more fime to complete the authorized activity, submit a request for extension under these GPs to the Municipal Planning Department prior to the expiration date. You may not continue work beyond the expiration date until receiving notification to that effect from the Municipal Planning Department or the Corps Regulatory Branch. of : Pernitlees should slow at least one month for processing of extension requests. 2. Other Approvals Required Before Starting Work. You must not disturb wetlands for this project until you have obtained all applicable Municipal and Stale approvals required for the work. These approvals include, but are not limited to: unlcioarrty ofAnchora ❑ Land Use Permit ® Grading & FlII Permit ® Building Permit ® Right -of -Way Permit ❑ Flood Hazard Permit ® UglilyAgreement(s) ❑ Rezoning Approval ❑ Preliminary Plat Approval ❑ Subdivision Agreement ® StormvaterTreatment Plan ❑ Parks Right -of -Entry Permit ® Wastewater Disposal ❑ Urban Design Commission ❑ Geotechnical Commission 1••%III/ 1 • 1\ l•J.II'1 ..1 ❑ StormwalerTreatment Plan ® Wastewater Disposal ❑ Soil Remediation Plan Mary Kron POA -2006-1424 Little Survival Creek 06-A If any of these—or other --approvals result In a change to the attached plans, you must provide a description of the change and a revised plan(s) to either Municipal Planning Department Staff or the Corps Regulatory Branch, and may not proceed with the project until the change Is au8wrized. 4. Offset Unavoidable Impacts. To offset the unavoidable adverse Impacts of the project to the aquatic environment, the permittee: ❑ shall provide an In -Lieu Fee In the amount of ($(2.939 x acreage a) $ prior to disturbing wetlands for this project. You may either submit this fee directly to the Great Land Trust or other nonprofit conservation group with whom the Corps has a Memorandum of Agreement or request that Municipal Planning Department Staff forward it to them. In either case, the fee transmittal shall Include both the GP reference number for the project and the extent of wetlands Impact (square feet or acres) it Is Intended to offset. ® Excluding lots located In new subdivision developments, single family homes kmpacting less than 16,500 square feet of wetlands are exempt from this requirement ❑ shall sign a Tolling Agreement with the Corps of Engineers, Regulatory Branch 5. Limits on Work Area. You must not conduct any of the following activities In wetlands or waterbodles beyond the approved project footprint (or In any other avoidance area Identified above) during either construction or operation of the project/facility. D Discharge of fill material (even temporarily), Including stockpiles; or, D Excavation and sidecastinglbackfilling; or, D Mechanized landdearing: or, D Operation, parking/storage or servicing of equipment S. Construction Runoff. You must employ runoff control measures necessary to preclude or minimize both erosion and the transport of sediment, pollutants, and solid waste beyond the approved project footprint These measures shag Include, but are not limited to: Phasing of Site Preparation (to minimize the extent of exposed soil); Sgt Fence; Reroute Offshe Runoff around Disturbed Soils (e.g., dike/ditch) Mulching (e.g., wood chips, straw, grass clippings, gravel); Matting (e.g., jute, straw, coir); Sheeting for Stockpiles, Temporarily Exposed Slopes (e.g., plastic, geotextile fabric); Check Dams in Dhches/Drainageways (e.g., hay bales, sand bags, gravel berms); Surface Roughening (to slow runoff down slope); Terracing of Slopes; Sediment Trap(s); Temporary Sediment Basin; Storm Drain Inlet Protection (e.g., hay bales, sand bags, gravel berm) Outlet FlItering/Stabilization for Construction Dewatering; Revegetation of Fills and Disturbed Soils Onsite petroleum spigAeak response equipment and supplies and provision for their proper disposal T. Contaminated Soil. If contaminated soils are discovered during consbuction, you must immediately cease all work in the vicinity of the contamination, contact the Alaska Department of Environmental Conservation for Instructions, and defer any further activity until you receive ADEC approval to continue. 8. Endangered Species. The activity must not jeopardize the continued existence of a threatened or endangered species, as identified under the Endangered Species Act, nor endanger the critical habitat of such species. Mary Kron POA -2006-1424 Little Survival Creek 06-A Your signature below, as permittee, confirms that you accept and agree to comply with the terms and conditions of Anchorage General Permit 93-10N, as supplemented in this document "MR, ll$1i�41 f 1 . I r, 11IuI 111 . 11, �1:%lI a se,�' ��.1'J • i Opinion �Jlaxna.- of Compliance The signature below confirms the Municipality of Anchorage's opinion that the project described above meets the terms and conditions of Anchorage General Permit 9340N. SIGN tMUNICIPAJ ;OFFICIAL' NAME;&<_TITLE DATE 144Arr% K-rsccec r— P it PRINT MUN DATE When the work authorized by the Anchorage General Permit is still in existence at the time the property is transferred the terms and conditions of the permit will continue to be binding on the new owner(s) of the property. To validate the transfer of the permit and the associated liabilities associated with compliance with its terms and conditions have the transferee sign and date below. (TRANSFEREE) (DATE) Attachments: Final Project Plans (sheet 1 of 1, dated August 14, 2006; updated 0131106) Mary Kron POA -2006-1424 Little Survival Creek 06-A SUSITNA VIEW ESTATES SUBDIVISION LOT 10, BLOCK 1 Scale: 1' = 50' Plan View Profile Notes: 1. All Revegetation Will Be Done With Topsoil And Grass. 2. All Cut And Fill Slopes Will Be Revegetated To Prevent Erosion. 3. Grades Will Not Be Changed At the Boundaries. 4. Excavated or Filled Areas Will Be Graded To Prevent Ponding/Flooding. Municipality of Anchorage Development Services Department �.r Building Safety Division *A. Onsite Water and Wastewater Program4700 South Bragaw St. P.O. Box 196650 Anchorage, AK 99519-6650 www.muni.orglonsite (907) 343-7904 ON-SITE SEWER/WELL SUBMITTAL COMMENT SHEET To: Mike Anderson Legal description: Susitna View Estates Block 1 Lot 10 The attached paperwork has been reviewed and is being returned for the following reasons: ❑ Original signature or stamp missing on ❑ Calculation error in design. _ ❑ Additional soils information needed. _ ❑ Water monitoring results inadequate. ® Discrepancy in information submitted. Found 25% slope less then 50 feet from Proposed system and altenote site. ❑ Topographic information missing or inadequate. ❑ Incomplete; missing ❑ Incomplete; missing ❑ Additional adequacy test Information needed. ❑ Water sample unacceptable. _ ❑ Measured/proposed distances/dimensions missing. ❑ Locations of all soils, percolation and water monitoring tests not shown. ❑ Proposed system too deep for soils Information submitted. ❑ Well log required. _ ❑ Omission in narrative. ❑ Insufficient fill over tank or field._ ❑ Other. _ Name of reviewer: Jeff Date: -29 1-06 Please supply the necessary information and re -submit your request. LEAVE -THIS- ORM ATTACHED TO THE -PAPERWORK Municipality of Anchorage Development Services Department �! Building Safety Division Onsite Water and Wastewater Program 4700 South Bragaw St. P.O. Box 196650 Anchorage, AK 99519-6650 www.ci.anchorage.ak.us (907)343-7904 ON-SITE SEWER/WELL SUBMITTAL COMMENT SHEET To: ANDERSON ENG Legal description: SUSITNA VIEW ESTATES BL 1 LT 10 The attached paperwork has been reviewed and Is being returned for the following reasons: ❑ Original signature or stamp missing on ❑ Calculation error in design. ❑ Additional soils information needed. _ ❑ Water monitoring results inadequate. _ ❑ Discrepancy In information submitted. _ ❑ Topographic information missing or inadequate. ❑ Incomplete; missing ❑ Incomplete; missing ❑ Additional adequacy test information needed. ❑ Water sample unacceptable. _ ❑ Measured/proposed distances/dimensions missing. ❑ Locations of all soils, percolation and water monitoring tests not shown. _ ❑ Proposed system too deep for soils information submitted. ❑ Well log required. ❑ Omission In narrative. ❑ Insufficient fill over tank or field._ ® Other. SEPTIC DESIGN ON WETLANDS PERMIT DIFFERS FROM PROPOSED LOCATION OF SEPTIC DESIGN ON ON-SITE PERMIT APPLICATION. Name of reviewer: JOE GOODALL Date: October 9, 2006 Please supply the necessary information and re -submit your request. LEAVE THIS FORM ATTACHED TO THE PAPERWORK ADVANCED WASTEWATER TREATMENT SYSTEM MAINTENANCE AND REPAIR AGREEMENT MEMORANDUM OF UNDERSTANDING BETWEEN MUNICIPALITY OF ANCHORAGE ANDVAiCIJetej e1t'I)Cvin gV%a -y- THIS MEMORANDUM OF UNDERSTANDING made and entered into as of this �a Dayof SaPrGyAlt of200L,byand between HjhQej QnC1tJCUt0.ghAYrlX herein the "OWNER," and the Municipality of Anchorage, herein the "MUNICIPALITY." In consideration of the mutual covenants contained herein, the parties to this Memorandum of Understanding agree as follows: 1. ADVANCED WASTEWATER TREATMENT SYSTEMS. Municipality grants permission to Owner to utilize and operate an Advanced Wastewater ADVA.iTay, 7-a-c4T&ts-" — Treatment System (AWWTS), described as Sy Srtsm located at LoTI D, $uoe.1`I SVerf NA tllt^j Anchorage, Alaska. 2. Definitions. 957*-rES A. Alteration. Any change to the design or function of an AW WTS that Includes the installation or removal of any parts, components or pieces not included in the original construction permit and design. Prior to performing any alterations to an AW WTS the owner must obtain a Wastewater Disposal System Construction Permit from the Municipality pursuant to Anchorage Municipal Code (hereinafter, "AMC") 15.65. B. Certificate of On -Site Systems Approval. An approval by the Municipality of existing water and wastewater disposal systems given at the time of property sale and title transfer in accordance with AMC 15.65. These approvals certify that the systems are adequate for the homes that they support and meet the codes that were in place at the time of system construction. C. Damage. Any man-made or natural change in a system that would inhibit the system from performing as designed. D. Ntaintenance and Repair. The scheduled and as needed replacement of existing parts, components and pieces of an AWWTS that were included in the original design which would allow the AWWTS to continue to perform as designed. E. Permit (Construction) An On -Site Wastewater Disposal System Construction Permit as defined by AMC 15.65. F. Permit (Operating) An Advanced Wastewater Treatment System Operating Permit. An annual permit, issued by the Municipality, that allows the Owner to operate an AWWTS, upon meeting all the requirements of this agreement, the conditions of Operating Permit, the requirements of the On -Site Wastewater System Construction Permit and all relevant provisions of AMC 15.65 3. Fee. Owner shall pay to Municipality an annual fee of /jO�j L- ($ 0.00), payable on or before the issuance of the operating permit and annually thereafter. The annual fee is due on or before the anniversary date of the approval by the Municipality of installed system. 4. Tenn. The term of this Memorandum of Understanding shall be for the life of the AWWTS. The term begins on the date of approval by the Municipality of the installed system and shall continue while the AWWTS system is in use or operational or until the property is sold or title is transferred by owner and a new certificate of On -Site approval is issued to the new owner or transferee of the property. 5. Alterations, Installation and Removal of Additional Equipment. Owner agrees not to make any alterations, removal of parts or additions to the AWWTS without a Construction Permit from the Municipality. 6. Maintenance and Repairs. A. Throughout the term of this Memorandum of Understanding, the Owner shall maintain AWWTS in good repair. In addition, it shall be the responsibility of the Owner during the term of this Memorandum of Understanding, and any extensions or renewals thereof, at the owner's sole expense, to pay for any and all: (1) repair(s), (2) maintenance, (3) adjustment(s), (4) replacement costs, and (5) inspection costs. Further, Owner agrees to comply will all applicable ordinance, laws, regulations, rules and orders for the AWWTS. B. Owner agrees to provide the Municipality a written schedule of routine maintenance and repairs which have been performed on the system pursuant to the terms and conditions contained in the Owner's AWWTS Operating Permit. This schedule shall be submitted to the Municipality annually upon the renewal of the permit. The schedule of maintenance and repair contained in the Owner's AW WTS / Operating Permit is: 1 eARL1( C. Owner acknowledges that the fine schedule for failing to maintain and repair an AWWTS are codified in AMC 14.60. D. Owner agrees that only maintenance, repair personnel certified by the Municipality will inspect and make any necessary maintenance, repairs or permitted alterations to the system. E. Owner agrees to grant the Municipality reasonable access to test and inspect the AWWTS upon 24 hours written notice. F. Owner agrees that any sale or transfer of title of the property will not occur without a new Certificate of On -Site Systems Approval. G. Owner agrees that the relevant provisions of the standard specification guidebook for AWWTS is the governing professional guidelines for the construction, maintenance and repair of the Owner's AWWTS. 7. Nonwaiver. The failure of either party at any time to enforce a provision of this Memorandum of Understanding shall in no way constitute a waiver of the provisions, nor in any way effect the validity of the Memorandum of Understanding or any part hereof, or the right of such party thereafter to enforce each and every provision hereof. 8. Amendment. A. This Memorandum of Understanding shall only be amended, modified or changed by a writing, executed by authorized representatives of the parties, with the same formality of this Memorandum of Understanding was executed and such writing shall be attached to this Memorandum of Understanding as an amendment. B. For the purposes of any amendment modification or change to the terms and conditions of this contract, the only authorized representatives of the parties are: Owner: Anchorage: PurchasingOflice C. Any attempt to amend, modify, or change this contract by either an unauthorized representative or unauthorized means shall be void. 9. Jurisdiction: Choice of Law. Any civil action arising from this Memorandum of Understanding shall be brought in the Superior Court for the Third Judicial District of the State of Alaska at Anchorage. The laws of the State of Alaska shall govern the rights and obligations of the parties under this Memorandum of Understanding. 10. Severability. Any provisions of this Memorandum of Understanding decreed invalid by a court of competent jurisdiction shall not invalidate the remaining provisions of the Memorandum of Understanding. OWNER: MUNICIPALITY: By: l/} r/jAt� By. �`—f Title: Date: 7 v Date: STATE OF ALASKA ) ) ss. THIRD JUDICIAL DISTRICT ) The foregom instrumgnt was acknowledged before me this Il day of lej-41a 292C , by NO—A-0. Ji LKLAtAl &tY0 NOTARY PUBLIC FOR ALASKA My Commission expires:,13, L'q