HomeMy WebLinkAboutFOREST CREEK LT 1Forest Creek Lot 1 #015-292-49 Municipality of Anchorage On -Site Water and Wastewater Program • (907) 343-7904 Page 1 of 3 ON-SITE WASTEWATER INSPECTION REPORT Permit Number: OSP191015 PID Number: 015-292-49 Dwelling: 9 Single Family (SF) ❑ Duplex (D) ❑ Multiple (SF and/or D) Project: ❑ New X Upgrade Name: Andrew S. Wakefield ABSORPTION FIELD ❑ Deep Trench ❑ Shallow Trench ❑ Bed ❑ Mound Address 10161 Our Rd. Anchorage, AK 99507 ❑ Other Phone Number of Bedrooms Soil Rating Total depth from original grade (907) 563-5656 5 EXISTING GPD/SF Ft. LEGAL DESCRIPTION Depth to pipe invert from original grade Ft. Gravel depth beneath pipe Ft. Subdivision Block Lot Forest Creek 1 Fill added above original grade Ft. Gravel length Ft. Township Range Section Gravel width Ft. Beds: Number of Lines Distance between lines Ft. SEPARATION DISTANCES To Septic Absorption Lift Station Holding Sewer Total absorption area Number of trenches Dist. between trenches From Tank Field Tank Line Ft Ft. Well >100' N/A N/A N/A >25' TANK 9 Septic ❑ S.T.E.P. ❑ Holding ❑ Other Manufacturer Anchorage Tank Capacity 1500 Gal. Surface Water >' 100 N/A N/A N/A Material Number of compartments Lot Line >10' N/A N/A N/A Steel 2 NA Foundation >10' N/A N/A N/A LIFT STATION Manufacturer Capacity Curtain Drain None N/A Gal. Remarks Insulation was used over septic tank. Pump on level at in. Pump off level at in. High water alarm at in. Pump make and model Electrical Inspections performed by PIPE MATERIAL House to tank D3034 Tank to D3034 drainfield Installer GLW Drainfield D3034. CO/MT Inspector J. Williams BENCH MARK (Assumed elevation) 100 ft Inspection15 5/6/19 Location and description dates: 2nd aro 4th Garage slab COMMUNITY DEVELOPMENT DEPARTMENT APPROVAL Engineer's Stamp Conditional Approval: OF Date ����P,,.••°°°" 'e 49th . ...... .... ....p.....m 6 .u..nan..nu.....u..a.uvvu..uau..mmum� %n MICHAEL E. ANDERSON e /)_6�.6 � �^ �v� ��C% '•� No. CE -4381 �� ,,, 10/28/19 e••°° Fp m............. Approved Date -021 #o P� ®� inspection Keport_y-i-iz.aoc PROFILE AS-BUILT (NO SCALE) 83.8 79.6 84.5 88.5FCOSV1 SV22CO1500 GAL SEPTIC TANK 83.65 PERMIT # OSP191015 PID # 015-292-49 FOREST CREEK LOT 1 10/28/19 2" INSULATION 1 I• 10' T&E EASEMENT X z � I II 30.00' I I II I I \ I PLOT PLAN ___ AS BUILT —X SCALE 1 Lot 1 40,122 s.f NOTE: PAVED PARKING ENCROACHES INTO ADJACENT RIGHT—OF—WAY Qt u A 5� G� z � I II 30.00' I I II I I \ I PLOT PLAN ___ AS BUILT —X SCALE 1 Lot 1 40,122 s.f NOTE: PAVED PARKING ENCROACHES INTO ADJACENT RIGHT—OF—WAY I Lot 2 10' T&E EASEMENTS METAL FENCE i'46"E 299.42' \ SEPTIC PIPES 1 WELL - .. ___ .._. ,. —._.._. _ Lang & Associates, inc. (907) 522-6476 Phone (907) 522-4625 Fax Professional Land Surveyors kenOlongsurvey.com jonathanOlongsurvey.com I hereby certify that I have surveyed the following described property: Lot 1, FOREST CREEK SUBDIVISION (Plat No. 2005-83) Anchorage Recording District, Alaska, and that the Improvements situated thereon are within the property lines and do not encroach onto the property adjacent thereto, that no improvements on the property lying adjacent thereto encroach on the surveyed premises and that there are no roadways, transmission lines or other visible easements on said property except as indicated hereon. Dated this the Day of —�a�->cU �__, "(tid"_tip_, at Anchorage, Alaska It is the responsibility of the owner to determine the existence of any easements, covenants, or restrictions which do not appear on the recorded subdivision plat. .ASPHALT.. PAVEMENT WOODEN FENCE r] SEE "HOUSE DETAIL GRAVEL 1 I I PATIO I Lot 5 NOTE: RETAINING WALL ENCROACHES ONTO ADJACENT LOT Lot 6 WOODEN FENCE I J./ II I „J N 89'56'45"WI 299.42' — WOODEN FENCE 10' UTILITY EASEMENTS / I Lob 4A2 Alaska 99515-3049 0F A.��S�4� I 49TH v, KE .. NG 940440 Z.Ls°� 02 Qp„ ESSIONA� _ AECC963 FISCHER Lot 3A5 S�1B 1VISION I 2.0 5.3' HOUSE DETAIL SCALE: 1"=30' Qt 5� G� �O Q I Lot 2 10' T&E EASEMENTS METAL FENCE i'46"E 299.42' \ SEPTIC PIPES 1 WELL - .. ___ .._. ,. —._.._. _ Lang & Associates, inc. (907) 522-6476 Phone (907) 522-4625 Fax Professional Land Surveyors kenOlongsurvey.com jonathanOlongsurvey.com I hereby certify that I have surveyed the following described property: Lot 1, FOREST CREEK SUBDIVISION (Plat No. 2005-83) Anchorage Recording District, Alaska, and that the Improvements situated thereon are within the property lines and do not encroach onto the property adjacent thereto, that no improvements on the property lying adjacent thereto encroach on the surveyed premises and that there are no roadways, transmission lines or other visible easements on said property except as indicated hereon. Dated this the Day of —�a�->cU �__, "(tid"_tip_, at Anchorage, Alaska It is the responsibility of the owner to determine the existence of any easements, covenants, or restrictions which do not appear on the recorded subdivision plat. .ASPHALT.. PAVEMENT WOODEN FENCE r] SEE "HOUSE DETAIL GRAVEL 1 I I PATIO I Lot 5 NOTE: RETAINING WALL ENCROACHES ONTO ADJACENT LOT Lot 6 WOODEN FENCE I J./ II I „J N 89'56'45"WI 299.42' — WOODEN FENCE 10' UTILITY EASEMENTS / I Lob 4A2 Alaska 99515-3049 0F A.��S�4� I 49TH v, KE .. NG 940440 Z.Ls°� 02 Qp„ ESSIONA� _ AECC963 FISCHER Lot 3A5 S�1B 1VISION I 2.0 5.3' HOUSE DETAIL SCALE: 1"=30' to I, 14FiUNICIPALITY OF ANC110RAGE 0 "ite Water & Wastewater Proyriirn n PC) Box '196650 4700 Elmore Pond Phone: (907)343-7904 Fm: (907)343-799/ On -Site Wastewater Disposal Systean Permit Permit Number: OSP191015 Effective Date: 1/23/2019 Work Type: SepticTank Upgrade Expiration Date: '1/23/2020 Tax Code Number-. 01529249000 Site Legal Address: FOREST GREEK LT 'I G:2537 Site Mailing Address* '10161 OUR RD, Anchorage Owner: WINSLOW MARK P 50% & I...ot Size in Sq Ft: 40122 Design Engineer: FORGE ENGINEERING Total Bedrooms: 5 This permit is for the construction of: El Disposal Field R Septic Tank El Holding Tank El Privy 0 Private Well El Water Storage All construction shall be in accordance with: 1. The attached approved design, 2. All requirements specified in Anchorage Municipal code Chapters 15,55 and 15,65 and the State of Alaska Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80) 3. The wastewater code requires inspections during the installation. The engineer shall notify the Development Services Department per AMC 15.65. Provide notification by calling (907) 343-7904 (2417), 4. From October 15 to April '15, a Subsurface soil absorption system under construction during freezing weather shall be either: a. Opened and Closed on the same day, or b. Covered, sealed, and heated to prevent freezing Received By: Issued By. Date: i/rDate: EPL,9NS MUNICIPALITY OF ANCHORAGE Community Development Department Phone: 907-343-7904 Development Services Division Fax: 907-343-7997 On -Site Water & Wastewater Program ON-SITE SEWER/WELL PERMIT APPLICATION Parcel I.D. 015-292-49 Property owner(s) Andrew S. Wakefield Mailing address 10161 Our Rd. Anchorage, AK 99507 Site address 10161 Our Rd Day phone Legal description (Sub'd., Block & Lot) Forrest Creek Lot 1 Legal description (Township, Range & Section) Lot Size 40,122 Sq. Ft. Number of Bedrooms 5 APPLICATION IS FOR: APPLICATION IS AN: TYPE OF DWELLING: (M all that apply) Absorption Field ❑ Initial ❑ Single Family (SF) ❑X Septic Tank 1ZUpgrade ❑X (w/wo ADU) Holding Tank ElRenewal ElDuplex (D) El Privy ❑ Multiple Dwellings ❑ (SF and/or D) Private Well ❑ Water Storage ❑ THIS APPLICATION INCLUDES A VARIANCE / WAIVER REQUEST FOR: Distance: I certify that the above information is correct. I further certify that this is in accordance with applicable Municipal Codes. U (Signature of property owner or authorized agent) Permit/Rush Fees: 1919 Date of Payment: /ei2-1 Iq Receipt Number: 61050D Permit No. (15PI9 1 1[' - Permit App_:• :- :'-._c Waiver Fees: Date of Payment: Receipt Number: Waiver No. January 22, 2019 MOA Development Services, On-Site Water & Wastewater Program 4700 Elmore Rd Anchorage, AK 99507 1/22/19 Subject: Forest Creek Lot 1 – 10161 Our Rd. Septic system design Dear On-Site Services Engineer: The owner of the above lot intends to build an addition to his home that encroaches over the existing septic tank, so we are submitting this permit application for the installation of a new septic tank that does not interfere with the addition. The attached site plan identifies the location of the home as well as the existing well, adjacent wells and septic location. No conflicts exist between this proposed system and any other well or septic system, whether on this lot or adjacent lots. The ground surface on the lot slopes toward the northwest. Stormwater drainage will not impact this septic system. The septic tank will be a minimum of 100’ from all wells and surface water, 10’ from the foundation, and more than 5’ away from the septic trench. Please refer to the attached plan. If this design is followed, there will be no adverse impacts to adjacent properties. Sincerely, Benjamin Schiller, PE Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP191015, Rebecca Carroll, 01/23/19 // // // // // // // // // // // // // // // // // // // // // // // // // // // // // // // // // // // // // // // // // // // // // NOTE: NO SLOPES >25% WITHIN 50' OR SURFACE WATER WITHIN 100' OF THE PROPOSED SEPTIC SYSTEM ALL WELLS ON SURROUNDING LOTS WITH IMPACTS TO THIS PROPERTY ARE SHOWN. NO CONFLICTS WITH WELLS OR SEPTIC SYSTEMS. CO - CLEANOUT 2CO - DOUBLE CLEANOUT FCO - FOUNDATION CLEANOUT FD - FLOW DIVERTER VALVE MH - MANHOLE MT - MONITORING TUBE SV - SEPTIC VENT TH - TEST HOLE LEGENDOUR ROADFOREST CREEK LOT 1 1"=50' FEET 0 50 100 Jan 22, 2019 10' T&E EASEMENT10' T&E EASEMENT10' UTILITY EASEMENT 5-BDRM HOME DECOMMISSION EXISTING TANK IN ACCORDANCE WITH MOA CODE EXISTING TRENCH 100' RADIUS EXISTING WELL INSTALL NEW 1500 GALLON SEPTIC TANK INSTALL DOUBLE CLEANOUT AFTER TANK NEW ADDITION NEW FOUNDATION CLEANOUT Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP191015, Rebecca Carroll, 01/23/19 l\ Municipality of Anchorage Development Services Department Building Safety Division .. . Onsite Water and Wastewater Program, 4700 Elmore Road P.O. Box 196650 Anchorage, AK 89507 Page of www .c"' chorage.ak.us (907) 343-7904 ON-SITE WASTEWATER DISPOSAL SYSTEM AND/OR WELL INSPECTION REPORT Permit Number. SW080024 PID Number. 015-29249 wn. The Dittrich Company Wastewater System: ❑� New ❑Upgrade Ada P.O. Box 90411 Anchorage, AIL 99509 ABSORPTION FIELD pl� 345.6277 or a ' 5 O D..p Ttrrm ld Swww Tram O SW O Mane 0 DFRr LEGAL DESCRIPTION Sa+R+mu Tar D.qn". mpnr QMW 1.2 GPD,Fr 6-9 FI 0� Lac 1 6�rmwrac Forest Creek D.oa M Pip. . aora alw p.M Grn Moa MrwM PM 4.5 FL 4 FL Tmn" R.V. S. . Fi apMa.ma mg." Vb Gravr Lrrpn. 2-3 Ft.63 Ft. Well: 21 New ❑Upgrade wr.'r w. DRtr axwwrMa. 5 Ft. FL Cn.rncrm (P . A e. 4 Tar D nm Caaa o. Tau" .awgxm r.a PP. M.ww Private 272 n 272 FL 630 Fl IASTM 03034 PVC Daw Dow Drr.a swop wa L. II w Dr. Imre.a MW Drilling 4/19/08 238 Fc Glacier Masonry 4/162008 yawPure Su u Da" Hegm a.� Grana. I TANK 10 GPM 253 - Ft. 2 FL SEPARATION DISTANCES 0 Septic ❑ Holding ❑ S.T.E.P. ❑ Other. To Septic ADsorptlon LM Holding lubiriPrivate '°"'0 y Ftom Tank Field Station Tank SrwrrUna Anchorage Tank 11,500 ON wu >100' >100' NIA WA >25' Mr.w Steel Irnr.r r CarpumarM Two (2) sMr.a.w" >100' >100' NIA N/A LIFT STATION s. wua. Lo U"' >5' >10' NIA NIA Gr 'KovwM a •Pure air Yw.L h.Yn wrr rarma Fantl"'"' >5' >10' WA N/A h M h C~ Drat None Noted Puny MM. a Moat El.canr hrap. Prtamua q Rwa.nu BENCH MARK Lamson ua D.•aipaa^. Garage Slab 100.0 FL Inspections performed by: A. Harala Dates: 10 4/162008 .,E�adtr,rer, w ,e �(� • v;,,•.44 Ep! a �Q.••••s �> �� '• 2nd 2 4/162008 r !7: 4 Development Services Department Approval *; 49-1H •, Conditional Approval Date: S� •,••, 0 1, I MICHAEL E ANDERSON•• - op J� ; CE-4381 •\�� r�,F� Reviewed and approved by: ate: PR-0iCSS10�A�' a:' i ilko...o�.`` (R. watt rn.o,� 1 �y4� N N POW I M.M.Q0.00 N -� r +"•••'' '"ti -V��1 3 F '1 i ; '#� -------------- —------ •� m Lr) IL S • Ne i IL r d O i oil 1. I � � I O I rn r I h O _ Ce) CL W y I F 'n o z zCDU O _ I LO 1 tl 0) Q O rndm� 0 pD I� F— W Y m a I a L❑ Q O N N U C LU rn (U Q; O N N c U I io cc v U) w 0= m I m _Z�Wcm wJd ,� N m Q o P -e b N , Q P cw dp U ¢ n �g 1 , F I W 0 m�H�hP I Q W eil:roe i Z y wU, o�m ®__ Q hW C.) iU I co y I IL o O 0 I V I I I I I I ,p I N 1 O I co '1N53 3 V '1 ,01 ,00'Kt MC,90D0 N .0 17 E _ z avow ano a �� Municipality of Anchorage DEVEOPMENT SERVICES DEPARTMENT 4700 South Bragaw Street Anchorage, AK. 99519-6655 - 343-7904 On -Site Wastewater Disposal System or Well Inspection Report Permit Number. SWO80024 v U 82.1 85.8 93.0 rN N UU 1,500 Gallon Septic Tank 84.7 Geotextile Fabric 78.1 Drainfield Rock I i 74.1-� — 64.1 No Groundwater 5121/07 PROFILE AS -BUILT - No Scale Page 3 of 3 PID No. 015-292-49 czS 78.1 zt � �oNF ZL COMMENTS PERCOLATION RATE I (mb•e M• ) PERC HOLE DUIMETER TEST RUN SETWEENTFT .'AND FT PERFORMED BY: j I 1wI r✓lL CERTIFY THAT THIS TEST WAS PERFORMED IN ACCORDANCE WITH ALLSTATE AND MUNICIPAUGUIDELINES IN EFFECT ON THIS DATE. DATE: Q- Z L - O is a Municipality of Anchorage *J' �+j'JYEYIJ�SEA41 *•� Development Services Department Building Safety Division �•_..`. •»• •» �••• On-SheWater and Wastewater PrO ram 9 """"""' "" ••• •••••••• E ANDERSON �`04, AW 4700 South Bragaw St. P.O. Box 195650 Anchorage, AK 99519.6550 �AVt]iAa 0 ciJ, :� , CE -4381 w (90anchor7904Y..us # e.,.. 40*0 ?.LZ O.�j`�Z.`4 . t,1�►giiw����'. Soils Log - Percolation Test ,,�' / Performed For. ' ►{, yi ffK " 4o. Date Performed: 3 3 f Legal Description: {�(/1 l�/j�eT.. Township, Range, Section:,...___ Slope Sde Plan Depth (Feet e•� OZr 1- 2- 3_ �M 4- 1 �- e ... 6 Rw!u•trs 7- 8- WAS GROUND WATER 9- ENCOUNTERED? �_ • 5 10- IF YES. AT WHAT DEPTH7 L 0 11- Depth to Water After Monitoring? E 12- Dale: 13- 14_ Reading Date Gross Time I Not Time Depth to Water Net Dino 15- ?J G. Co IIv 17- }aLt3o / 16- ibt 3 I 20- 5%4�1I I<rV zt � �oNF ZL COMMENTS PERCOLATION RATE I (mb•e M• ) PERC HOLE DUIMETER TEST RUN SETWEENTFT .'AND FT PERFORMED BY: j I 1wI r✓lL CERTIFY THAT THIS TEST WAS PERFORMED IN ACCORDANCE WITH ALLSTATE AND MUNICIPAUGUIDELINES IN EFFECT ON THIS DATE. DATE: Q- Z L - O is a 89/18/2008 11:51 9073453287 MW DRILLING PAGE 02/02 M -W Drilling, Inc. *P.O. Box 110378*Anchorcge, AK 99511• •907-345-4000 • 907-345-3287 Fax• Job No. 08.120 Well Owner. Dittrich Legal Description: Lot 1, f GROUNDWATER WELL AS -BUILT & LOG Use of Well: Domestic CONSTRUCTION Hole Depth: 272' Casing Size: a' Cased To: 272' Material: A 53 Steel Drill Method: Air otary Wall: =. Well Completion: Open end X Screen Perforated Pert. Method: Screen/ Perforation description: Grout Notes: ( 2) Sack(s) of No. Bentonite granuies Notes: Disinfected: No Meth Well Development Method Air Surge Notes: Static water level (SWL) 238' below top of casing (TDC). Well yield test at 10 Tag.—per minute (GPM) for 1 hour(s) with l00% of drawdown (DD) from static level(SWL). Method: Air Litt — Stan Date: / /O8 Completion Date: 4/24/08 Pump Install Date: 8/27/08 w�p—q pthof test from top Details; of formations penetrated, size of material, colorand miscellaneous details. 0 2.5 TO TO 3 5 Casing Stick Up Overburden 5 TO 108 Gravel: silty with Inter -bedded, cobbly zones 108 TO 111 Water Gravel: Silty, l-2gpm, med(um to fine 111 TO 253 Gravel: Silty, cobbly, brown 253T0 259 Water Gravel: medium, 2-3 gpm 259 TO 266 Gravel: silty, wet, light brown 266 70 272 Water Gravel: medium to coarse, 10gpm TO T TO I►YNE-EAMTISERG S-'- MW6tDr9lhlaJnc N0A C&5W Mama Gmimdr*K C0nbX or TO To TO TO Cantredors irre�JAo. TO 09/18/2008 15:17 9073453287 IMI DRILLING PAGE 03/03 Development Services Department Building Safety Division 0 ay On -Site Water & Wastewater Program P* 4700 Elmore Road P.O. Box 196650 Mark Begteh Anchorage, AK 99507 Mayo! eww.mvni.erd�en9itt (907)343-7904 Pump Installation Log Well Drilling Permit Number: SWj2_1�_c92L4 Date of Issue: _q_$— 08 Parcel Identification Number: 292 ^ yQ Legal Description Lot 1. Foneet Creek Subdivision Anchorage, AK 99509 Pump Installation Date: &27,08 Pump Intake Depth Below Top of Well Casing: 253 Pump Manufacturer's Name: arunfos Pump Model: losoE1s.100 Pump Size Kone) hp Pitless Adapter Burial Depth: 10' feet Piticss Adapter Manufacturer's Name: s^enens0n Pitlam Adapter Installer: &w Drtuing. Inc, Well Disinfected Upon Completion? ❑ Yes ® No Method of Disinfection: Comments, Pump Installer Name: rv1-wmitiing.lm feet Jarele DeIrk:h dbe DinAch Company 10161 Our Road (P.O. Bow 90,411) Anchcrege. AK 99309 Attention: The pump installer shall provide a pump installation log to the DSD within 30 days of pump Installation. MUNICIPALITY OF ANCHORAGE \ Development Services Department On -Site Water 8 Wastewater Program ` t 4700 South Bragaw Street P.O. Box 196650, Anchorage, AK 99519-6650 �t (907) 343-7904 ON-SITE WASTEWATER DISPOSAL SYSTEM / WATER SUPPLY PERMIT Initial Permit Number: SW080024 Legal Description: FOREST CREEK LOT 1 Design Engineer: 0014 ANDERSON ENGINEERING Owner Name: THE DITTRICH COMPANY Owner Address: PO BOX 90411 ANCHORAGE. AK 99509 - Date Issued: Apr 03, 2008 Expiration Date: Apr 03, 2009 Parcel ID: 015-29239 IOIL4PI Site Address: NHN OUR ROAD Lot Size: 40122 SQ. FT. Total Bedrooms: 5 Permit Bedrooms: 5 This permit is for the construction of: ❑; Disposal Field [?] Septic Tank ❑ Holding Tank ❑ Privy Q Private Well ❑ Water Storage All construction must be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal Code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72 ) and Drinking Water Regulations ( 18AAC80 ). 3. The engineer must notify DSD at least 2 hours prior to each inspection. Provide notification by calling (907) 343-7904 ( 24 hours ). ( Not required for a Water Supply Permit only ). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must be either: A. Open and closed on the same day. B. Covered, sealed, and heated to prevent freezing. 5. The following special provisions. THE ENTIRE SUBSURFACE DISPOSAL FIELD IS NOT WITHIN A 30 FOOT RADIUS OF A PERCOLATION TEST OR GROUNDWATER MONITORING. THE ENGINEER NEEDS TO DO A COMPLETE SOILS LOG PRIOR TO THE CONSTRUCTION OF THE SEPTIC FIELD. PLEASE SUBMIT STAMPED AND SIGNED RESULTS WITH THE AS -BUILT INSPECTION REPORT. IF THE RESULTS REQUIRE A DESIGN CHANGE, CONSTRUCTION OF THE SYSTEM WILL STOP PENDING ON-SITE REVIEW AND APPROVAL. Received By: Date: el - 0 \ Municipality of Anchorage • -� Development Services Department ���" : n �• Building Safety Division On -Site Water and Wastewater Program ' 4700 Bragaw Street P.O. Box 196650 Anchorage, Alaska 99519-6650 www.muni.org/onsite (907)343-7904 ON-SITE SEWER/WELL PERMIT APPLICATION FOR A SINGLE FAMILY DWELLING Parcel I.D. 015-29249 Property owner(s) The Dittrich Company Day phone 632-5790 Mailing address P.O. Box 90411 Anchorage, AK Zip Code 99509 Site address N 4i fJ Our Road Zip Code 99516 Legal description (Sub'd., Block & Lot) Forest Creek, Lot 1 Legal description (township, Range & Section) Lot Size 40.122 Sq. Ft. Number of Bedrooms Five (5) THIS APPLICATION IS FOR (® all that apply): THIS APPLICATION IS AN: Absorption Field Q Initial Q Septic Tank Q Upgrade ❑ Holding Tank ❑ Renewal ❑ Privy ❑ Private Well Water Storage ❑ certify that the above information is correct. I further certify that this application is being made for a Single Family Dwelling and is in accordance with applicable Municipal Codes. 1q—jL1 .0 (Signature of property owner or authorized agent) Permit/Rush Fees: 'Waiver Fees: Date of Payment: 3 /p Date of Payment: Receipt Number. 105n9 5 Receipt Number. (Rev. 11105) ANDERSON ENGINEERING P.O. BOX 240773 ANCHORAGE, AK 99524 MEMORANDUM DATE: April 1, 2008 TO: Deb Wockenfuss FROM: Mike Anderson, P.E. SUBJECT: Lot 1, Forest Creek Subdivision Septic System Construction Permit The following information is provided to resolve comments concerning our application for a well and septic system permit for Lot 1, Forest Creek Subdivision: 1. The subdivision was originally called Dittrich Subdivision. The File No. was S- 11250-1. 2. Existing soil logs were submitted with the original application. Logs from adjacent lots can be found in the subdivision file. 3. No well was located on the lot during the subdivision phase. An application for construction of a well was made, but the well was not constructed. 4. Easements have been added to the Area Map. 5. The existing well on Lot 3A5 Fischer Subdivision has been added. All wells within 200' of the new absorption system are now shown on the Area Map. 6. An additional test hole will be completed prior to construction of the new absorption trench. The new trench will be constructed entirely within the 30' radius of this hole. Construction of the system will stop pending further review and approval if soils encountered in the test hole vary from other test holes on the lot. ANDERSON ENGINEERING P.O. BOX 240773 ANCHORAGE, AK 99524 March 12, 2008 Municipality of Anchorage Development Services Department On -Site Water and Wastewater Program 4700 South Bragaw Street Anchorage, AK 99519-6650 Subject: Lot 1, Forest Creek Subdivision Septic System Design and Permit Application Impacts to Adjacent Properties Dear Onsite Services Engineer: The owner of Lot 1, Forest Creek Subdivision intends to construct a new five -bedroom home on the lot. We are therefore requesting a permit be issued for the construction of a new well and septic system to accommodate the home. The attached Site Plan and backup documentation identify the location and configuration of the proposed well and septic system along with the alternate site. Also identified on the plans are the existing wells and septic systems on surrounding lots. No conflicts exist between the proposed well and septic system and wells or septic systems on adjacent lots. Drainage arrows are shown on the site plan showing the grade and direction of flow on the lot. The drainage pattern will not be changed as a result of this project. The test holes were placed on the lot in the area of the absorption trench and alternate site during the subdivision phase. Additional test holes will be required as these holes are further than 30' from the new sites due to placement of the well on the lot. We are requesting the test holes be placed during the construction phase of the new absorption trench. All test holes in the subdivision have revealed the same or similar soils. The logs indicate well graded sand (SP/SW) to depths of 18'. The percolation rate of the soil was determined to be between 1 and 5 minutes per inch. No groundwater was found during the placement of the test hole and none was noted during the monitoring period. An application rate of 1.2 gallons per day per square foot was used in the design of the absorption system. We are proposing to place a new 1,500 -gallon septic tank and a 63' long by 5' wide by 4' effective depth absorption trench to treat and dispose of the effluent generated in the house. The elevation of the distribution line in the absorption trench will be 4' below the surface and the total depth will be 8'. A minimum of 3' of fill or 2" of insulation and 2' of fill will be placed over the absorption trench and 4' over the septic tank. Lot 1, Forest Creek Subdivision March 12, 2008 Page Two The ground surface on the lot in the area of the septic system slopes to the northwest. The new trench will be constructed parallel with the slope as much as possible in conformance with Municipal requirements. The new septic system will be constructed a minimum of 100' from all wells and any surface water and 10' the proposed and existing water services in the area. The system will be constructed outside the Class B Wetland Boundary shown on the Site Plan. If the system is constructed in accordance with our design the following statements apply: The system, if constructed as designed, will have no adverse impact on the wells in the area or those to be constructed in the future. 2. The system, if constructed as designed, will have no adverse impact on existing septic systems in the area or those to be constructed in the future. 3. The system, if constructed as designed, will have no adverse impact on reserve space, either surface or subsurface, on any lots located in the area. 4. The system, if constructed as designed, will have no adverse impact on drainage patterns in the area. The current drainage pattern will be maintained. Sincerely, w n — Michael E. Anderson, P.E. Attachments TRACT A (VACANT) - uc O LOT 3 LOT 4 ; �r LOT 2 1 LOT 5 , (VACANT) LOT 6 LOT t 1 .� IG . o JGJ i `. • AREA MAP ai49th � `:'�•i - ---- �- SCALE 1' = 100' f^ j NIC/NR L NIpERSW i� •��`,1 N0. cc-ate ............. .� ••••�, ��. ,• J M.0 LO U 3.°i� OWL A.M.BODO N •!1193 sr -110 I N z N ms t 1 m oWo^ r 11 0 4; I r W ___l a L' -J y W O LL -it / ®_ I I I I I I •i • - ---- •• - - - - -- d1 Lam[ 1V:', 11"m 3 s .1 .0 T ;�. i^' 7 a`•"� ,OOYCI M,ZC.BOAON � 00, v; U�•:t T Z 1��••.• M1 F i i M 0•Y. • avoa ano - LOT 1, FOREST CREEK SUBDIVISION DESIGN FACTORS: SYSTEM REQUIREMENTS: Five Bedroom Home 5' Wide Trench System Perc. Rate: 1.2 Min./Inch 1,500 Gallon Septic Tank Application Rate: 1.2 GPD/SF 4' Drainfield Rock 5 Bedrooms X 150 GPD/1.2 GPD/SF (Application Rate) = 625 SF Absorption Area 625 SF/5 LF (Width)•.5 (Red. Factor) = 62.5 LF Trench Length THEREFORE: Construct a 63' Long x 5' Wide x 4' Effective Depth Absorption Trench at the Location Shown. Flow Line Elevation in Trench to be 4' Below Original Ground Surface. Total Depth to be 8' Below Existing Ground. Provide 4' Cover Over Septic Tank and 3' Cover Over Absorption Trench. Maintain 100' Separation from Welts in the Area. NOTE: Natural Backfill 3'6" G.5 4'0" I 5' -; ICAL DEE (NO Geotextile Fabric Perforated 'C (Holes Down) Drainfield Rock TRENCH SECTION Grade Area Over Trench to Drain Away. Minimum 6' Separation From Bedrock. Minimum 4' Separation From Groundwater. Minimum 100' Separation From Wells in the Area. Minimum 100' Separation From Surface Water or Streams. MUNICIPALITY OF ANCHORAGE DEVELOPMENT SERVICES DEPARTMENT 4700 SOUTH13RAGAW STREET ANCHORAGE, ALASKA 99519-6650 SOILS LOG - PERCOLATION TEST PERFORMED FOR: Jamie Dittrich DATE PERFORMED: 2/92004 LEGAL DESCRIPTION: Proposed Lot 1. Dittrich Subdivision j�j��TTj�TT�� TEST HOLE # 11 SL—OPE—SITE PLAN IIIIIIIII OG/OL I I '1111:11 0 3- 5- 6 56 7a 8 9 10 11 17J .° O SP/SM Poorly Graded to Silty Sand Olive Dry WAS GROUNDWATER GROSS TIME NET TIME ENCOUNTERED? No S 2:15 L IF YES, WHAT DEPTH? 1 0 DEPTH OF WATER None P AFTER MONITORING: 2:26 E DATE: 2242004 2 2:36 s7 -1v -77 -,Do ve Dry _49th _ 0. %M c�woemaw ♦ No. eea i e444ea';;71�. BOH @ 20' SEE SITE PLAN FOR TEST HOLE LOCATION Varies READING DATE GROSS TIME NET TIME DEPTH OF WATER NET DROP Start 222 2:15 8.75' 1 2:25 10 Dry 8.75' Recharge 2:26 8.5' 2 2:36 10 Dry 8.5' Recharge 2:37 8.5' 3 2:47 10 Dry 8.5' PERC RATE:1_1 MIN./INCH PERC. HOLE DIAMETER:8" TEST RUN BETWEEN 6 FT. AND 6 T. COMMENTS: Test Hole Pre Soaked Prior to Test TEST PERFORMED BY: ALAN HARALA I, MICHAEL F. ANDERSON, CERTIFY THAT THIS TEST WAS PERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES ON THIS DATE: 2/242004 MUNICIPALITY OF ANCHORAGE DEVELOPMENT SERVICES DEPARTMENT 4700 SOUTH BRAGAW STREET ANCHORAGE, ALASKA 99519-6650 SOILS LOG - PERCOLATION TEST PERFORMED FOR: Jamie Dittrich DATE PERFORMED: 2/9/2004 LEGAL DESCRIPTION: Proposed Lot 1. Dittrich Subdivision �jT�� TEST HOLE # 12 SLOPE SITE PLAN II1111111 OG/OL II I 2 a 3 4 ° 5- 6- 7- 8- 9 67 89 4 10 11 12 13 a SP/SM Poorly Graded to Silty Sand Olive WAS GROUNDWATER ENCOUNTERED? No Dry IF YES, WHAT DEPTH? DEPTH OF WATER None AFTER MONITORING: DATE:2/24/2004 srs •a#y r 49th BOH @ 21' S L 0 P E SEE SITE PLAN FOR TEST HOLE LOCATION Varies READING DATE GROSS TIME NET TIME DEPTH OF WATER NET DROP Start 2/22 2:50 8,75- 1 3:00 10 Dry 8.75' Recharge 3:01 8.5' —2— —1-3:10-1-10— _Dry Recharge 3:11 8.5' 3 3:21 10 Dry 8.5' PERC RATE:1_1 MIN./INCH PERC. HOLE DIAMETER: 8_ TEST RUN BETWEEN 5 FT. AND 8 T. COMMENTS: Test Hole Pre Soaked Prior to Test. 28% to 30% Slope Down Hill From Test Hole. TEST PERFORMED BY: ALAN HARALA I, MICHAEL F. ANDERSON, CERTIFY THAT THIS TEST WAS PERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES ON THIS DATE: 2/24/2004 ON-SITE WASTEWATER DISPOSAL SYSTEM CONSTRUCTION AND MATERIAL SPECIFICATIONS SUBJECT: LOT 1, FOREST CREEK SUBDIVISION GENERAL: 1. The scope of this project includes the procurement and placement of a new 1,500 -gallon septic tank at the location shown on the Site Plan. Work also includes the construction of a new 63' long X 5' wide X 4' effective depth absorption trench at the location also shown on the Site Plan. The distribution line in the trench will be placed at 4' below the existing ground surface. Total depth of the trench will be 8' below the existing ground surface. The new absorption trench and septic tank must be placed a minimum of 100' from all private wells and any surface water in the area and 10' from the water service line proposed for the lot. A minimum of 3' of cover is required over the absorption trench and 4' of cover over the septic tank. 2. Construction shall be in accordance with the approved site plan, design drawings, Municipal Permit with any special provisions or conditions, and all applicable State and Municipal Wastewater Disposal Regulations. 3. The Contractor shall be responsible for obtaining all underground utility locates and for the layout of the septic system and verification of the location of all lot lines. The Contractor must also verify the location of wells in the area and assure that the separation distances are met. 4. Unless specifically agreed otherwise, the contractor shall be responsible for final grading areas subsequently depressed from soil settling. Property owner shall be responsible for revegetation of affected areas unless specifically agreed otherwise. 5. Contractors installing wastewater disposal systems must be certified by the Municipal Development Services Department Building Safety Division On Site Water and Wastewater Program for system installations. Owners installing their own systems must receive prior approval from the On Site Water and Wastewater Program before beginning system installation. SEPTIC TANK INSTALLATION A new 1,500 -gallon septic tank must be procured from an approved source and installed at the location shown. 2. A septic tank is to be constructed by a certified septic tank manufacturer. Construction shall include two 4" cleanouts for pumping access. Lot 1, Forest Creek March 12, 2008 Page 2 of 3 3. The septic tank shall be sufficiently bedded to prevent settling or shifting of the tank. 4. All standpipes on the septic tank shall extend a minimum of 12 inches above final grade. 5. Tanks installed without 4' of cover shall have a minimum of 2" of direct burial insulation. 6. A foundation cleanout shall be installed one to four feet from the building foundation. Two cleanouts are required between the tank and the drainfield. 7. Final grading over the tank shall be such that a positive slope exists away from the septic tank. DRAINFIELD CONSTRUCTION: 1. The drainfield shall be constructed to the dimensions shown on the design. The bottom of the trench shall be within 2" of level. 2. Distribution piping must be placed level with perforations down atop a level bed of drainfield rock. Rock should then be placed over the pipe to provide a minimum of 2" of cover. 3. A silt barrier or geotextile fabric must be placed between the drainfield rock and the natural soil backfill. 4. Monitor tubes must be 4" in diameter and installed at the locations shown on the design. The portion below ground must be perforated. 5. Contractor shall verify the septic tank and drainfield are a minimum 100' away from any private water wells in the area, 150' from a Class "C" Well or 200' from any community well. 6. Direct bury insulation must be placed over the distribution system if less than 3' of backfill depth is available. Finish grade over the trench must be mounded to prevent settlement or depressions. 7. Grade area surrounding the absorption trench to drain away. 8. A minimum 2' of accepting soil is required below the drainfield rock for a 5' wide trench. Contractor shall verify this condition prior to placement of the rock. All pockets of unacceptable materials must be removed and replaced. Lot 1, Forest Creek March 12, 2008 Page 3 of 3 MATERIAL SPECIFICATIONS: Septic tanks must be constructed by a municipally approved septic tank manufacturer. 2. The following pipe materials are approved for use in septic system installations in the Municipality of Anchorage: Cast Iron (perforated and solid), ASTM D3034 or P.V.C. (perforated and solid), ASTM F810 or H.D.P.E. (perforated, but not solid) and ASTM D2662 or A.B.S. (perforated and solid). Insulation shall be at least 2" thick extruded direct burial polystyrene (Dow Chemical Co. Styrofoam HI or equal). 4. Septic tank inlets and outlets shall be fitted with watertight couplings (Caulder, Femco, or equal). A permeable geotextile fabric (Typar, Mirafi or equal) must be installed between the final drain rock layer and the native soil layer. 6. All drain rock shall be .5" to 2.5" in diameter with less than 3% passing the #200 sieve. INSPECTIONS: Municipal Ordinance requires a minimum of two inspections. These inspections must be conducted under the supervision of a professional engineer registered in the State of Alaska. The first inspection must be conducted after the excavation of trenches, beds or pits and before the installation of any gravel. A septic tank may be set in place, but may not be backfilled. The second inspection must be conducted after the placement of the geotextile fabric, gravel, distribution piping, standpipes, cleanouts and insulation. No backfill should be in place at the time of inspection. Contractor shall provide a copy of all field survey layout and construction notes for use in preparing the certified as -built of the completed system. r MUNICIPALITY OF ANCHORAGE Development Services Department On -Site Water & Wastewater Program 4700 South Bragaw Street P.O. Box 196650, Anchorage, AK 99519-6650 (907) 343-7904 ON-SITE WATER SUPPLY PERMIT Initial Date Issued: Jun 18, 2004 Expiration Date: Jun 18, 2005 Permit Number: SWO40208 +ii1b1TrR(e _ Lo7; f 1 Parcel ID: 015-292-29 Legal Description: FtSGHER-13116 J.QJ Design Engineer: 0014 Anderson Engineering Owner Name: DITTRICH COMPANY Site Address: OUR RD Lot Size: 0 SO. FT. Owner Address: PO BOX 90411 Total Bedrooms: 1 Permit Bedrooms: 1 ANCHORAGE. A 99509 - This permit is for the construction of: ❑ Disposal Field ❑ Septic Tank ❑ Holding Tank ❑ Privy Private Well ❑ Water Storage All construction must be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal Code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72 ) and Drinking Water Regulations (18AAC80 ). 3, The engineer must notify DSD at least 2 hours prior to each inspection. Provide notification by calling (907) 343-7904 ( 24 hours ). ( Not required for a Water Supply Permit only ). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must be either: A. Open and closed on the same day. B. Covered, sealed, and heated to prevent freezing. 5. The following special provisions. - WHEN THE WELL HAS BEEN COMPLETED AND SATISFACTORY WATER PRODUCTION HAS BEEN DETERMINED, THE WELL DRILLER SHALL PLACE AN APPROVED SANITARY SEAL ON THE WELL HEAD AND NO PITLESS ADAPTER OR PUMP SHALL BE INSTALLED UNTIL AN APPROVED WASTEWATER DISPOSAL SYSTEM HAS BEEN CONSTRUCTED. TN 'S r6ttp .i T rs Ford THE 1'e0P0j.'G ArTTr2 r c r/ sG G.o7 i Received By: Date: G — ZZ -0 y Issued By: l l l r Date:'60 Parcel I.D. Municipality of Anchorage Development Services Department Building Safety Division On -Site Water and Wastewater Program 4700 South Bragaw SL P.O. Box 196650 Anchorage, AK 99519-6650 www.ci.anchorage.ak.us (907)343-7904 ON-SITE SEWER/WELL PERMIT APPLICATION FOR A SINGLE FAMILY DWELLING sr- _Zy Scy(E2 Lo7 , Number SW Property owner(s) Dittrich Company Day phone 636.8730 Mailing address (1) P.O. Box 90411 Anchoraae, AK 99509 Mailing address (2) Zip Code Legal description (Lot, Block & Sub'd.) Lot 1. Block 2, Fischer Subdivision • (Lot 1, Dittrich Sub. Proposed) Legal description (Section, Township & Range) Lot Size TBD Acres/Sq.Ft. THIS APPLICATION IS FOR: Number of Bedrooms TBD Sewer Only ❑ Well Only ED Sewer and Well ❑ Water Storage ❑ Sewer Upgrade ❑ THIS PROPERTY CONTAINS: Hot Tub ❑ Jacuzzi ❑ Swimming Pool ❑ Water Softening Unit ❑ Therapy Pool ❑ certify that the above information is correct. I further certify that this application is being made for a Single Family Dwelling and is in accordance with applicable Municipal Codes. (Signature of property owner or authorized agent) Permit Fees: a I '� Waiver Fees: Date of Payment: ( D I q I Date of Payment: Receipt Number. <-� 1 Receipt Number. (Rev. 12100) ANDERSON ENGINEERING P.O. BOX 240773 ANCHORAGE, AK 99524 FAX MEMO DATE: 6116/2004 TO: Dan Roth WITH: MoA/On Site Services FROM: Mike Anderson SUBJECT: Dittrich Subdivision Test Well Locations MESSAGE: Attached is the revised drawing showing the location of the wells for the subject lots. Let me know what you think. 2 Pages Being Transmitted. Please call 522-7773 If not complete. 1 LJ I VY LLL_ LV V/'1 I I V I V J wac 1'-100' G TEST MOLE LOCAnON5 ANDERSON ENGINEERING P.O. BOX 240773 ANCHORAGE, AK 99524 MEMO DATE: 6/9/2004 TO: Joe Goodall WITH: MoA/OnSite Water and Wastewater FROM: Mike Anderson SUBJECT: Lots 1 and 2, Block 2, Fischer Subdivision Well Construction Permits Lots 1 and 2 of Fischer Subdivision are currently being subdivided into 6 lots and a tract. An aquifer test is required prior to the completion of the subdivision. We are therefore applying for permits to construct 3 wells on the property to complete the aquifer test. The locations of the wells are shown on the attached drawings. Please refer the information and issue the permits so the well can be constructed and the test completed. Please let me know if you have additional questions. Feb -24. 2004 10:I6AM 9015226119 No -5361 P. 14/15 9 m J 111 -- -�- VENUE KOO 3A4I SFLDON CIRCLE `" I 112 x 48-1 49-2 3A3 / / 3A2 \) Z) 3A1 30, 30, z 0 O N SNOI1V301 310H 1S31 0 -== . 31V3S �IV134 1M .Ob'666 3_2S.6G_6p S ,vn vVn >„VV,VV.vu N cry 3'S ZLO'Ob n 'J'S ILO'04 W 9 10l w 4 w O - O N N U N 3 � 3.Zf,6S.E8 S of LG6Z 3„Z9 — —if . ,G9 O O� 'A'S Z1O'04 �' 4 i S 1 u L R 2 101 p U v In U O OL ® 06C "L,9'69.6d S o�" w'_'S b I:i O 7C4 a ,3�5 04CA r -V io-ILM • b4 O N c � 101 I „Z£,6;,68 S 0 \ OddS N3d0 'J'S L69'99L v 1odN1 06L k8VONnOB SONVl13M 8 SSM- SV13—.-41 -41 'ON 310 33S r d�' r ----- - -- -- -- ,vn vVn >„VV,VV.vu N • G C �L • tom Municipality of Anchorage .�' On-Site Water and Wastewater Program (907) 343-7904 s, F E T Y Certificate of On-Site Systems Approval Parcel I.D. 015-292-49 Expiration Date: I 0 "2-C9 `11 1. GENERAL INFORMATION Complete legal description Forest Creek, Lot 1 Location (site address) 10161 Our Road Current Property owner(s) Andrew Wakefield Day phone Mailing address 10161 Our Rd, Anchorage, AK 99507 Real Estate Agent Shannon Ingram Day phone 748-7861 2. TYPE OF DWELLING: El Single Family (w/wo ADU) ❑ Duplex ❑ Multiple Dwellings (Single Family and/or Duplex) 3. NUMBER OF BEDROOMS: 5 4. TYPE OF WATER SUPPLY: TYPE OF WASTEWATER DISPOSAL: Individual Well Individual Individual Water Storage ❑ Holding Tank ❑ Community Class Well ❑ Community ❑ Public Water System ❑ Public Sewer ❑ WaiverNariance request for: Distance: Received by: ,00/0/60 fiV. Date: I/ i4/I / COSA to be released to the engineer,unless otherwise requested by the engineer. COSA Fee $ 5.9 Waiver Fee $ Date of Payment .3-1(94R Date of Payment Receipt Number (i 3 - ' C Receipt Number COSA# 3C f -12 t2 Waiver# 5. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based on procedures outlined in the Certificate of On-Site Systems Approval Guidelines for this application, shows that the on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation. Name of Firm Anderson Engineering Phone 522-7773 Address 1399 W 34th Ave, Anchorage, AK 99503 Engineer's Printed Name Benjamin Schiller Date 7-16-2017 o 1:77 e 49ii-+ P. • •� 6. DSD SIGNATURE o 'ems System #1 Approved for tok � .e. ..,•u • pp 5 bedrooms d • a: •°. }3•It! j '`T ea w System #2 Approved for bedrooms vt, ,, -12592 .; 4, Disapproved i4JI41 Conditional approval for bedrooms, with the following stipLili tl' trtsr ON-SITE WATER AND i`' WASTEWATER c PROGRAM Original Certificate Date: 7-2._c_5 — The —ZC5 —The Municipality of Anchorage Development Services Division (DSD) issues Certificates of On-Site Systems Approval (COSA) based only upon the representations given in paragraph 5 by an independent professional civil engineer registered in the State of Alaska. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. 7. ATTACHMENTS: `r COSA Checklist X Nitrate Advisory Septic System Advisory Arsenic Advisory Well Flow Advisory Other • COSA blue sheet r .. c If more than 1 septic system is on the lot: COSA Checklist# of Structure served by this system Certificate of On-Site Systems Approval Checklist Legal Description: Forest Creek, Lot 1 Parcel ID: 015-292-49 A. WELL DATA Well type Private If A, B, or C provide PWSID# _ Well Log (Y/N) Y Date completed 4/24/08 Sanitary seal (YIN) Y Wires properly protected (Y/N) Y Total depth 272 ft. Cased to 272 ft. Casing height(above ground) 31 in. FROM WELL LOG AT INSPECTION Date of test 4/24/08 7/14/17 Static water level 238 ft. 245 ft. Well production 10.0 g.p.m. 4.7 g.p.m. WATER SAMPLE RESULTS: Coliform l••;I. , colonies/100 mL Nitrate -1. mg/L Arsenic t..,'. . ug/L Date of sample: ? - 5= 1-7 Collected by: Anderson Eng B. SEPTIC/HOLDING TANK DATA Tank Type/Material Septic / Steel Date installed 4/1 6/08 Tank size 1 500 gal. Number of Compartments 2 Cleanouts (Y/N) Y Foundation cleanout(Y/N) Y - Depression over tank (Y/N) N High water alarm (Y/N) N Date of pumping 7 - ZC0-! I7 Pumper A+ Home Services C. ABSORPTION FIELD DATA Date installed 4/16/08 Soil rating (g.p.d./ft2 or ft2/bdrm) 1 .2 gpd/sf System type 5-Wide Length 63 ft. Width 5'0 ft. Gravel below pipe 4.0 ft. Total depth 13.6 ft. Eff. absorption area 630 ft2 Monitoring tube Y Depression over field N Date of adequacy test 7/1 4/1 7 Results (Pass/Fail) Pass For 5 bedrooms Fluid depth in absorption field before test 2 in. Water added 750 gal. New depth 27 in. Elapsed Time: 1 440 min. Final fluid depth 2 in. Absorption rate >= 750 g.p.d. No Any rejuvenation treatment (past 12 mo.) (Y/N &type) If yes, give date D. LIFT STATION Date installed Size in gallons Manhole/Access (Y/N) "Pump on" level at in. "Pump off' level at in. High water alarm level at in. Datum Cycles tested Meets alarm&circuit requirements? E. SEPARATION DISTANCES WELL ON LOT TO: Septic tank/lift station on lot >100' On adjacent lots >1001 Absorption field on lot '100 On adjacent lots >100' Public sewer main >75' Public sewer manhole/cleanout >100' Sewer/septic service line >25' Holding tank >75' Animal containment areas >50' Manure/animal excrete storage areas >100' SEPTIC/HOLDING TANK ON LOT TO: >5' >5' >5' Building foundation Property line Absorption field Water main >10' Water service line >10'0 Surface water >100' Wells on adjacent lots >100' ABSORPTION FIELD ON LOT TO: Property line Building foundation >10 Water main _ X10 Water Service line Surface water >100Driveway, parking/vehicle storage >10' Curtain drain None Noted Wells on adjacent lots '100' F. COMMENTS G. ENGINEER'S CERTIFICATION •�¢� •Or�el4 �Od � I certify that I have determined through field inspections and .... dA review of Municipal records that the above systems are in 0 : 4q:Ili f" 1. •v I.conformance with MOA COSA guidelines in effect on this date. 0 ., Benjamin Schiller • -°•••' Engineer's Printed Name / in )1 $Chit!@!' . Date 7/16/17 �i '•, GE-12532 ; ;e' ,'••7/I(.-((7 COSA brown sheet 10-10-12.doc 2005-83 FOREST CREEK SUBDIVISION LOT 1 40,122 S.F. S 89'56'46-E 299.42' • • . • SEPTIC SYSTEIJ o i, o pI o L,, • • o Q i PO PO 0 W • ►- U) M w173'�I DECK Li m 0 o • 'D L O o 4 t 4,7' •� n bb - ~ o Z - 3.2' o o 0 0 Cork. WAU----« o r' io Z 16.8' 0 N - 6•0' 1 ? =30' 0' EXISTING BUILDING •0 A.C. DRIVE '° 60.0' WELL i 0• T. & E. ESOT. "' ♦ 217.4' A :te =A ---rI• 22 4' S 89'55'451 299.42' A } `FENCE (APx) AS - BUILT I HEREBY CERTIFY THAT I HAVE SURVEYED THE PROPERTY DEPICTED ABOVE AND THAT NO *1tr �� + GASTALDI LAND ENCROACHMENTS EXIST EXCEPT AS INDICATED. SURVEYING, LLC ♦ F, �� A.. '� IT IS THE RESPONSIBILITY OF THE OWNER TO ♦ '� •••••••. 4 JEFF A. GASTALDI, R.L.S. DETERMINE THE EXISTENCE OF ANY EASEMENTS. t'�Q. • 4. . �' 2000 E. DOWUNG RD., SUITE 8 COVENANTS OR RESTRICTIONS WHICH DO NOT *C°:: 4gl�i d' *•f ANCHORAGE, ALASKA 99507 APPEAR ON THE RECORDED SUBDIVISION PLAT. as s PHONE 248-5454 UNDER NO CIRCUMSTANCES SHOULD ANY DATA lipt.3,44------1,-4........„_ GR.D DATE HEREON BE USED FOR CONSTRUCTION OR FOR ` v J�H�ry A. Gastalal 1 2537 8/26/�C:.B ESTABLISHING BOUNDARY OR FENCE LINES. ♦ '�,.•.� Ls-��1 ,:� • ANCHORAGE RECORDING DISTRICT, ALASKA �. •aP•'••••••••• t. F.B. JOB NO. `4 rCf•1f10nOt'' +• 08-07 FCS1 NOTE: NO CORNERS SET THIS DATE +alias1'‘w • Municipality of Anchorage Gr,' Q Apt. L. • � ,1��_i° Development Services Department Building Safety Division SAFETY On-Site Water and Wastewater Program 4700 Elmore Street P.O. Box 196650 Anchorage, AK 99519-6650 www.muni.org/onsite (907) 343-7904 Nitrate Advisory Certificate of On-Site Systems Approval # OSC 171298 A Certificate of On-Site Systems Approval inspection and test of potable water was recently conducted on the well water supply on Block 1, Lot of Forest Creek subdivision. This inspection revealed a nitrate concentration of 7.82 milligrams per liter (mg/L) was reported for the property's well water sample. The Environmental Protection Agency (EPA) has established a maximum contaminant level (MCL) of 10.0 mg/L for public drinking water systems. While private wells are not subject to this regulation, EPA standards are based on existing health information and can therefore be used to gauge the relative quality of water from private wells. Please see the attached "Nitrate Fact Sheet" for important information regarding nitrate. This advisory must be attached to all copies of the subject Certificate of On- Site Systems Approval. Nitrate Fact Sheet From Northern Testing Laboratories,Inc. Nitrate is a negatively charged compound of nitrogen and oxygen, which is very soluble in water. Nitrate is not readily filtered or otherwise removed in the soil and can pass rapidly into ground water wells. SOURCE: Nitrate is a major component of fertilizer and wastewater. Often the nitrate is in the form of ammonia or protein first, which through contact with oxygen and certain bacteria, converts to the oxidized form known as nitrate. Sources of nitrate from wastewater include urea, ammonia cleaners, food solids, and bacterial cells. It may also result from the breakdown of organic matter buried in the soil. TOXICITY: Nitrate is generally not toxic to adults or children over the age of two or three years, but is associated with a potentially fatal infant disease called methemoglobinemia. In the digestive system of young children, nitrate converts to nitrite, which can pass through the intestinal wall into the blood stream. There it combines with the hemoglobin and interferes with the ability of the blood to carry oxygen. For this reason, methemoglobinemia is referred to as "blue baby" disease. The EPA limits the concentration of nitrate in public drinking water supplies to 10 mg/L. The standard has been lowered from a previous level of 45 mg/L set by the US Public Health Service and the World Health Organization. TREATMENT: due to its solubility in water and negative ionic charge, filtration and other common home water treatment systems such as softening or iron filtration does not readily remove nitrate. The best method for limiting nitrate in well water is source control. This can include avoiding overdosing of fertilizer near the well and maintaining good separation distances between septic tank leach fields and the well. A special anion exchange filter that contains a media with a strong affinity for negatively charged ions in water, or by a reverse osmosis treatment system or distillation can remove nitrate. TESTING: Nitrate analysis is usually done by one of the several "wet chemical" methods using a spectrophotometer to read the final color endpoint. Specific ion electrodes also can be used to detect the activity of nitrate in water. This laboratory uses several different wet chemical methods approved under the public water supply laboratory certification program. They also have test kits available, which the laboratory uses to perform an inexpensive "screening test", and with which the homeowner can monitor the change in nitrate levels from their well. They recommend comparing the test kit results against a certified analysis from the lab occasionally to verify the accuracy of the kit. We recommend using a specially prepared bottle that has been rinsed in hydrochloric acid for collecting samples. • Municipality of Anchorage On -Site Water and Wastewater Program (907)343-7904 Parcel I. D. 015-292-46 Certificate of On -Site Systems Approval 1. GENERAL INFORMATION Complete legal description Location (site address) FOREST CREEK LOT 1 Expiration Date: tl _o? 3 - 10161 OUR RD., ANCHORAGE, AK 99516 Current Property owner(s) RONEL STEPHENS Mailing address Real Estate Agent MARY STEPHENS 2. TYPE OF DWELLING: (] Single Family (w/wo ADU) ❑ Duplex ❑ Multiple Dwellings (Single Family and/or Duplex) 3. NUMBER OF BEDROOMS: 5 Day phone Day phone 273-7706 4. TYPE OF WATER SUPPLY: TYPE OF WASTEWATER DISPOSAL: Individual Well 0 Individual 0 Individual Water Storage ❑ Holding Tank ❑ Community Class Well ❑ Community ❑ Public Water System ❑ Public Sewer ❑ Waiver/Variance request for: NONE Distance: Received by: l! )'r a> -- Date: COSA to be released to the engineer, unless otherwise requested by the engineer. COSA Fee $ !_i I 0 / Waiver Fee $ _ Date of Payment -7 ��i I Z 3 Date of Payment Receipt Number U 7 w Receipt Number COSA # / 3 /.3 3 1? Waiver # 5. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based on procedures outlined in the Certificate of On -Site Systems Approval Guidelines for this application, shows that the on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation. Name of Firm SPURKLAND ENGINEERING Phone 279-3916 Address 203 W. 25TH AVE.,STE.202A, ANCHORAGE, AK 99501 Engineer's Printed Name LARS SPURKLAND 6. DSD SIGNATURE System #1 Approved for S� bedrooms System #2 Approved for bedrooms Disapproved Date 1121L19.. _°_...,; i s @t{d Conditional approval for bedrooms, with the following stipulations: By: �a• Original Certificate Date: 1 — 02- 3 _/ The niId nchorage Development Services Division (DSD) issues Certificates of On -Site Systems Approval (COSA) based only upon the representations given in paragraph 5 by an independent professional civil engineer registered in the State of Alaska. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. ATTACHMENTS: COSA Checklist X Nitrate Advisory Septic System Advisory Arsenic Advisory Well Flow Advisory Other COSA blue sheet f , - If more than 1 septic system is on the lot: COSA Checklist # 1 of 1 Structure served by this system 1 Certificate of On -Site Systems Approval Checklist Legal Description: FOREST CREEK LOT 1 A. WELL DATA Well type PRIVATE If A, B. or C provide PWS ID # - Date completed 4/19/08 Sanitary seal (Y/N) Y Total depth 272 ft. Cased to 272 ft. FROM WELL LOG Date of test 4/19/08 Static water level 238 Well production 10 WATER SAMPLE RESULTS ft. Coliform NEG colonies/100 mL Nitrate 6.32 mg/L Arsenic ug/L Date of sample: 1/10114 B. SEPTIC/HOLDING TANK DATA Tank Type/Material SEPTIC/ STEEL Tank size 1500 gal. Number of Compartments 2 Foundation cleanout (Y/N) Y Date of pumping 7/15113 C. ABSORPTION FIELD DATA Date installed 4116/08 Parcel I D: 015-292-49 Well Log (Y/N) Y Wires properly protected (Y/N) Y Casing height (above ground) >24 in. AT INSPECTION 6/18/13 245 3.2 ft. Collected by: Lars Spurkland Depression over tank (Y/N) N Pumper A+ HOME SERVICES Soil rating (g.p.d./ft2 or ft2/bdrm) 1_2 Date installed 4/16/08 Cleanouts(Y/N) Y High water alarm (Y/N) N System type 5 -WIDE Length 63 ft. Width 5 ft. Gravel below pipe 4 ft. Total depth 14 ft. Eff. absorption area 630 fe Monitoring tube Y Depression over field N Date of adequacy test 6/18/13 Results (Pass/Fail) PASS For 5 bedrooms Fluid depth in absorption field before test 14,0 in. Water added 610 22.5,3 p rp gal. New depth in. Elapsed Time: 20 min. Final fluid depth 19'0 in. Absorption rate >= 750 9 p d Any rejuvenation treatment (past 12 mo.) (Y/N & type) NO If yes, give date - D. LIFT STATION Date installed "Pump on" level at _ Datum Size in gallons Manhole/Access(Y/N) in. "Pump off' level at in. High water alarm level at in. E. SEPARATION DISTANCES WELL ON LOT TO: Cycles tested Septic tank/lift station on lot >100' - Absorption field on lot >100' Public sewer main »5 Sewer /septic service line 25 Animal containment areas >50' Meets alarm & circuit requirements? On adjacent lots >100, On adjacent lots >100, Public sewer manhole/cleanout >100, Holding tank NA Manure/animal excrete storage areas >100' SEPTIC/HOLDING TANK ON LOT TO: Building foundation >5 Property line >5 Water main NA Water service line >10 Wells on adjacent lots >100' ABSORPTION FIELD ON LOT TO: Property line >10 Building foundation >10, Water Service line >10 Surface water >100'(N.O.) >50' (N.O.) >100, Curtain drain Wells on adjacent lots F. COMMENTS * Arsenic Sample Date 6-18-13 G. ENGINEER'S CERTIFICATION t certify that l have determined through field inspections and review of Municipal records that the above systems are in conformance with MOA COSA guidelines in effect on this date. Engineer's Printed Name LARS SPURKAND Date 1/21114 COSA brown sheet -1 0-10-1 2.doc Absorption field >5 Surface water >100' (N.O.) Water main NA gNehicle Driveway, arkin >25 y p storage 9 spuNmfid Enah emong Environmental Consulting and Design 0 1 SEPTIC SYSTEM DESIGN Municipality of Anchorage January 22, 2014 Development Services Department On Site Water and Wastewater Program 4700 Elmore Road Anchorage, Alaska 99519 Subject: COSA- Forest Creek Lot 1 Ladies and Gentlemen: On June 18, 2013 the septic system at the above reference property was tested. The septic system was design for a 5 bedroom single family residence and consists of a 1500 gallon steel septic tank and a shallow trench absorption field with four feet of effective absorption depth. Prior to the testing on June 18th, a liquid level of 14 inches and 0 inches were observed in each of the trench monitor tubes. A total of 610 gallons was added to the absorption field, causing the liquid level in each monitor to rise 8.5 and 3 inches respectively. During a 20 min period the liquid level dropped 3.5 and 3 inches in each monitor tube. A calculated absorption rate of 14.4 gallons per minute was observed during the recovery period. The equals in excess of 20,000 gallons per day, greatly exceeding the minimum required for a 5 bedroom system (750 gpd). A well production rate of 3.2 gallons per minute was observed. This also exceeds the minimum required for a 5 bedroom residence (0.52 gpm). If you have any questions or concerns, please contact me at 279-3916. Lars S urkland. P.E. 203 West 15th Avenue Suite 203, Anchorage, AK 99501, Phone: (907) 279-3916 Fax: (866) 354-1597, Lspurkland@gci.net • '� Municipality of Anchorage `>. On -Site Water and Wastewater Program (907)343-7904 �^ s =e„ Certificate of On -Site Systems Approval Parcel I.D. 015-292-46 Expiration Date: "I /Z 1 �1 `i 1 GENERAL INFORMATION Complete legal description FOREST CREEK LOT 1 Location (site address) 10161 OUR RD., ANCHORAGE, AK 99516 Current Property owner(s) RONEL STEPHENS Mailing address Real Estate Agent MARY STEPHENS 2. TYPE OF DWELLING: Fx� Single Family (w/wo ADU) ❑ Duplex ❑ Multiple Dwellings (Single Family and/or Duplex) 3. NUMBER OF BEDROOMS: 4 Day phone Day phone 273-7706 4. TYPE OF WATER SUPPLY: TYPE OF WASTEWATER DISPOSAL: Individual Well Individual 0 Individual Water Storage ❑ Holding Tank ❑ Community Class Well ❑ Community ❑ Public Water System ❑ Public Sewer ❑ WaiverNariance request for: NONE Distance: Received by: " f tl� l %' Date. 6 i1' COSA to be released to the eng(neer, unless otherwise requested by the engineer. - COSA Fee $ Lq Go Date of Payment 717113 Receipt Number 02557 G COSA # 05G / 3133 5 Waiver Fee $ Date of Payment Receipt Number Waiver # 5. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based on procedures outlined in the Certificate of On -Site Systems Approval Guidelines for this application, shows that the on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation. Name of Firm SPURKLAND ENGINEERING Phone 279-3916 Address 203 W. 25TH AVE.,STE.202A, ANCHORAGE, AK 99501 Engineer's Printed Name LARS SPURKLAND 6. DSD SIGNATURE ✓ System #1 Approved for r bedrooms System #2 Approved for bedrooms Disapproved Date 1121/14 Conditional approval for bedrooms, with the following stipulations: ,,. By: k1nk/ f, � 3e ODed" (rc cer+; s,ca+ Original Certificate Date: 7,A-311-3 The Municipality of Anchorage Development Services Division (DSD) issues Certificates of On -Site Systems Approval (COSA) based only upon the representations given in paragraph 5 by an independent professional civil engineer registered in the State of Alaska. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. 7. ATTACHMENTS: COSA Checklist X Nitrate Advisory Septic System Advisory Arsenic Advisory Well Flow Advisory Other COSA blue sheet -E - If more than 1 septic system is on the lot: COSA Checklist # 1 of 1 Structure served by this system 1 Certificate of On -Site Systems Approval Checklist Legal Description: FOREST CREEK LOT 1 A. WELL DATA Well type PRIVATE If A, B, or C provide PWSID # - Date completed 4/19/08 Sanitary seal (YIN) Y Total depth 272 ft. Cased to 272 ft. FROM WELL LOG Date of test 4/19/08 Static water level 238 Well production 10 WATER SAMPLE RESULTS P ..- Coliform NEG colonies/100 mL Nitrate 6.32 mg/L Arsenic ND I ug/L Date of sample: 1/10/14 4 61163/ 1_5 B. SEPTIC/HOLDING TANK DATA Parcel ID: 015-292-49 Well Log (Y/N) Y Wires properly protected (Y/N) Y Casing height (above ground) >24 in. AT INSPECTION 6/18/13 245 3.2 ft. NO00 Collected by: Lars Spurkland Tank Type/Material SEPTIC/ STEEL Date installed 4/16/08 Tank size 1500 gal. Number of Compartments 2 Cleanouts (Y/N) Y Foundation cleanout (Y/N) Y Depression over tank (Y/N) N High water alarm (Y/N) N Date of pumping 7/15/13 Pumper A+ HOME SERVICES C. ABSORPTION FIELD DATA Date installed 4/16/08 Length 63 ft. Soil rating (g.p.d./ft2 or ft2/bdrm) 1_2 System type 5 -WIDE Width 5 ft. Gravel below pipe 4 ft. Total depth 14 ft. Eff. absorption area 630 ft2 Monitoring tube Y Depression over field N Date of adequacy test 6/18/13 Results (Pass/Fail) PASS For 4 bedrooms Fluid depth in absorption field before test 14 in. Water added 610 gal. New depth 22.5 in. Elapsed Time: 20 min. Final fluid depth 19 in. Absorption rate >= 600 g p d Any rejuvenation treatment (past 12 mo.) (Y/N & type) NO If yes, give date - D. LIFT STATION Date installed Size in gallons "Pump on" level at in. "Pump off" level at Datum E. SEPARATION DISTANCES WELL ON LOT TO: Cycles tested Septic tank/lift station on lot '100' - Absorption field on lot '100' Public sewer main '75 Sewer /septic service line '25 Animal containment areas '50' Manhole/Access(Y/N) in. High water alarm level at in. Meets alarm & circuit requirements? On adjacent lots '100' On adjacent lots '100' Public sewer manhole/cleanout '100' Holding tank NA Manure/animal excrete storage areas '100' SEPTIC/HOLDING TANK ON LOT TO: Building foundation 'S Property line >5 Water main NA Water service line '10' Wells on adjacent lots '100' ABSORPTION FIELD ON LOT TO: Property line '10 Building foundation '10' Water Service line '10' Curtain drain '50' (N.O.) F. COMMENTS G. ENGINEER'S CERTIFICATION Surface water '100'(N.O.) Wells on adjacent lots '100' 1 certify that / have determined through field inspections and review of Municipal records that the above systems are in conformance with MOA COSA guidelines in effect on this date. Engineer's Printed Name LARS SPURKAND Date 1121/14 COSA brown sheet 10-10-12.doc Absorption field's Surface water '100' (N.O.) Water main NA Driveway, parking/vehicle storage25� Iq Parcel I.D. 015-2924 �P4 Municipality of Anchorage On -Site Water and Wastewater Program (907)343-7904 Certificate of On -Site Systems Approval 1. GENERAL INFORMATION Complete legal description FOREST CREEK LOT 1 Expiration Date: / 0 a 3-13 Location (site address) 10161 OUR RD., ANCHORAGE, AK 99516 Current Property owner(s) RONEL STEPHENS Mailing address Real Estate Agent MARY STEPHENS 2. TYPE OF DWELLING: Fx� Single Family (w/wo ADU) ❑ Duplex ❑ Multiple Dwellings (Single Family and/or Duplex) 3. NUMBER OF BEDROOMS: 4 Day phone Day phone 273-7706 4. TYPE OF WATER SUPPLY: TYPE OF WASTEWATER DISPOSAL: Individual Well El Individual 0 Individual Water Storage ❑ Holding Tank ❑ Community Class Well ❑ Community ❑ Public Water System ❑ Public Sewer ❑ WaiverA.ariance request 'or: NONE Distance: --- Received by _"L Date COSA to be released to the engineer, unless otherwise requested by the engineer. COSA Fee $ l o Date of Payment 1 111 Receipt Number Oo't JrJ 1 tn' COSA# 65L t ?-) 1335 Waiver Fee $ Date of Payment Receipt Number Waiver # 5. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based on procedures outlined in the Certificate of On -Site Systems Approval Guidelines for this application, shows that the on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation. Name of Firm SPURKLAND ENGINEERING Address 203 W. 25TH AVE.,STE.202A, ANCHORAGE, AK 99501 Engineer's Printed Name LARS SPURKLAND 6. DSD SIGNATURE _,z System #1 Approved for Tj / bedrooms System #2 Approved for bedrooms Disapproved Phone 279-3916 Date 7/8/13 \� OF qq lit 49 LA aXSPU�F�1,KLAND.,t2j: i roo/ Conditional approval for bedrooms, with the following stipulations: By: Z41, Original Certificate Date: / -,2 3 The' nib' al�/ Anchorage Development Services Division (DSD) issues Certificates of On -Site Systems Approval (COSA) based only upon the representations given in paragraph 5 by an independent professional civil engineer registered in the State of Alaska. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. 7. ATTACHMENTS: COSA Checklist X Nitrate Advisory Septic System Advisory Arsenic Advisory Well Flow Advisory Other COSA bluesheet f y c If more than 1 septic system is on the lot: COSA Checklist # 1 of 1 Structure served by this system 1 Certificate of On -Site Systems Approval Checklist Legal Description: FOREST CREEK LOT 1 A. WELL DATA Well type PRIVATE If A, B, or C provide PWSID # Date completed 4119108 Sanitary seal (Y/N) Y Total depth 272 ft. Cased to 272 ft. Parcel ID: 015-292-49 Well Log (YIN) Y Wires properly protected (Y/N) Y Casing height (above ground) >24 in. FROM WELL LOG AT INSPECTION Date of test 4/19/08 6/18/13 Static water level 238 ft 245 ft Well production 10 g.p.m. 32 g.p.m. WATER SAMPLE RESULTS Coliform NEG colonies/100 mL Nitrate 9.17 mg/L Arsenic ND ug/L Date of sample: 6/18/13 Collected by: ANSON MOXNESS B. SEPTICIHOLDING TANK DATA Tank Type/Material SEPTIC/ STEEL Date installed 4/16/08 Tank size 1500 gal. Number of Compartments Cleanouts (YIN) Y Foundation cleanout (Y/N) Y Date of pumping 7/XX/13 Depression over tank (Y/N) N High water alarm (YIN) N Pumper A+ HOME SERVICES C. ABSORPTION FIELD DATA Date installed 4/16108 Soil rating (g.p.d./ftZ or ft2/bdnn) 1.2 System type 5 -WIDE Length 63 ft. Width 5 ft. Gravel below pipe 4 ft. Total depth 14 ft. Eff. absorption area 630 fe Monitoring tube Y Depression over field N Date of adequacy test 6118/13 Results (Pass/Fail) PASS For 4 bedrooms Fluid depth in absorption field before test 14 in. Water added 610 gal. New depth 225= n. Elapsed Time: 20 min. Final fluid depth 19 in. Absorption rate >= 600 g p d Any rejuvenation treatment (past 12 mo.) (Y/N & type) NO If yes, give date — D. LIFT STATION Date installed Size in gallons _ Manhole/Access (YIN) "Pump on" level at in. "Pump off' level at in. High water alarm level at Datum E. SEPARATION DISTANCES WELL ON LOT TO: Cycles tested Septic tank/lift station on lot >100' - Absorption field on lot >100' Public sewer main >75 Sewer /septic service line >25 Animal containment areas >50' Meets alarm & circuit requirements? On adjacent lots >100, On adjacent lots >100, Public sewer manhole/cleanout >100, Holding tank NA Manure/animal excrete storage areas >100, SEPTIC/HOLDING TANK ON LOT TO: Building foundation >5 Property line >5 Water main NA Water service line >10' Wells on adjacent lots >100' ABSORPTION FIELD ON LOT TO: Property line >10 Building foundation >10, Water Service fine >10' Surface water >I00'(N.O.) Curtain drain >50' (N.O.) Wells on adjacent lots >100, F. COMMENTS G. ENGINEER'S CERTIFICATION I certify that t have determined through field inspections and review of Municipal records that the above systems are in conformance with MOA COSA guidelines in effect on this date. Engineer's Printed Name LARS SPURKAND Date 7/8/13 COSA brown sheet 10-10-12.doe Absorption field >5 Surface water >100' (N.O.) Water main NA Driveway, parking/vehicle storage >25 Municipality of Anchorage s , Community Development Department Development Services Division On -Site Water and Wastewater Program 4700 Elmore Street P.O. Box 196650 Anchorage, AK 99519-6650 www.muni.org/onsite (907)343-7904 Nitrate Advisory Certificate of On -Site Systems Approval # 131335 A Certificate of On -Site Systems Approval inspection and test of potable water was recently conducted on the well water supply on Block , Lot 1 of Forest Creek subdivision. This inspection revealed a nitrate concentration of 9.17 milligrams per liter (mg/L) was reported for the property's well water sample. The Environmental Protection Agency (EPA) has established a maximum contaminant level (MCL) of 10.0 mg/L for public drinking water systems. While private wells are not subject to this regulation, EPA standards are based on existing health information and can therefore be used to gauge the relative quality of water from private wells. Please see the attached "Nitrate Fact Sheet" for important information regarding nitrate. This advisory must be attached to all copies of the subject Certificate of On - Site Systems Approval. Municipality of Anchorage Development Services Department Building Safety Division Onsite Water and Wastewater Program 4700 Bragaw Street P.O. Box 196650 Anchorage, AK 995196650 www.muni.org/onsite (907)343-7904 CERTIFICATE OF ON-SITE SYSTEMS APPROVAL FOR A SINGLE FAMILY DWELLING Qp x Parcel I.D. 015-29249 COSA # [)00✓� Expiration Date: / — f — d 1. GENERAL INFORMATION Complete legal description Lot 1, Forest Creek Subdivision Location (site address) 10161 Our Road Anchorage, AK 99516 Current Property owner(s) The Dittrich Company Day phone 632-8970 Mailing address P.O. Box 90411 Anchorage, AK 99509 Lending agency Day phone Mailing address Real Estate Agent Day phone Mailing Address Unless otherwise requested, COSA will be held by DSD for pickup. 2. NUMBER OF BEDROOMS: Five (5) 3. TYPE OF WATER SUPPLY: TYPE OF WASTEWATER DISPOSAL: Individual Well Individual On-site ❑d Individual Water Storage ❑ Individual Holding Tank ❑ Community Class Well ❑ Community On-site ❑ Public Water System ❑ Public Sewer ❑ The Municipality of Anchorage Development Services Department (DSD) issues Certificates of On -Site Systems Approval (COSA) based only upon the representations given in paragraph 4 by an Independent professional civil engineer registered in the State of Alaska. Certificates of Onsite Systems Approval are required for the transfer of title (except between spouses) for properties served by a single-family on-site wastewater disposal and/or water supply system. DSD also issues COSAs upon request to homeowners. Certificates of Onsite Systems Approval are valid for 90 days from the date of issue for properties served by a private or Class C well and may be reissued with new water sample results. (Certificates may be reissued for a period of up to one year with valid water samples.) Certificates are valid for one year for properties served by Class A or B wells or a public water system. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. 4. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my Investigation, based on procedures outlined In the Certificate of On -Site Systems Approval Guidelines for this application, shows that the on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from my Investigation and inspection, the on-site water supply and/or wastewater disposal system is(are) In compliance with all applicable Municipal and State codes, ordinances, and regulations In effect at the time of installation. Name of Firm Anderson Engineering Phone 522-7773 Address P.O. Box 240773 Anchorage. AK 99524 Engineer's Printed Name Michael E. Anderson, P.E. Date SIM= * 491H 6. DSD SIGNATURE Ir"- Q a 50'x: � i I. Ir" - CE -4381 �..' �Approvedfor bedrooms. i@epfo.9�zt�?�•��4 Disapproved. t��1 fta`ss oO-' Conditional approval for bedrooms, with the following stipulations: Attachments: COSA Checklist Septic System Advisory Well Flow Advisory Nitrate Advisory X Arsenic Advisory Maintenance Agreements Supplemental Engineer's Report Other By: Original Certificate Date: 0 O (rs« 11M) Municipality of Anchorage •,, Development Services Department Building Safety Division ' ' On -Site Water& Wastewater Program 4700 Bragaw Street P.O. Box 196650 Anchorage, AK 995196650 www.muni.org/onsfte (907)343-7904 CERTIFICATE OF ON-SITE SYSTEMS APPROVAL CHECKLIST Legal Description: Lot 1. Forest Creek Subdivision Parcel ID: 015-29249 A. WELL DATA Well type Pdvate Date completed 479/08 Total depth 272 ft. Date of test Static water level Well production If A. B, or C provide PWSID # _ Sanitary seat (Y/N) Y Cased to 272 fL FROM WELL LOG 4119108 238 ft. WATER SAMPLE RESULTS: 10 Coliform 0 colonies/100 mL Arsenic: NID mg/1 _ 9 -P.M. Well Log (Y/N) Y Wires properly protected (Y/N) Y Casing height (above ground) >24 in. AT INSPECTION ' ft. g.p.m. Nitrate 7.72 mg/I­ Other bacteria 0 colonies/100 mL Date of sample: 9m�s Collected by: J. Davis B. SEPTICIHOLDING TANK DATA Tank Type/Material Septic/Steer Tank size ,1,500 gal. Number of Compartments Two Foundation cleanout (Y/N) Y Depression over tank (YM) N Date of pumping New Conswction Pumper Date installed 4i1e10e Cleanouts (Y/N)_ High water alarm (Y/N) Y N C. ABSORPTION FIELD DATA Date installed 4/18108 Soil rating (g.p.dAlt or ft=/bdrn) t2 GPD1SF System type S vnde Trend, Length 83 ft. Width 5 ft. Gravel below pipe 4 R Total depth 12-13 ft. Eff. absorption area 830 ft2 Monitoring tube Y Depression over field N Date of adequacy test New Const. Results (Pass/Fail)For_bedrooms Fluid depth in absorption field before test in. Water added Bal. .New depth in. Elapsed Time: min. Final fluid depth in. Absorption rate >= g.p.d. Any.rejuvenation treatment (past 12 mo.) (Y/N & type) N If yes, give date D. LIFT STATION �+rVl4 •'�J;f t, N Date installed Size in gallons Manhole/Access (Y/N) 'Pump on' level at — In. 'Pump oft level at_ in. High water alarm level at . In. Datum Cycles tested Meets alar 8 circuit requirements? E. SEPARATION DISTANCES .Mrd1a ' yO : 2t t7WDER5pry �� r SEPARATION DISTANCES FROM WELL ON LOT TO: G��✓�E''i38� �\y= / O v Septic tankAift station on lot 21100' On adjacent lots 21100• Absorption field on lot >100' On adjacent lots >100, Public sewer main WA Public sewer manhole/cleanout WA Sewer/septic service line >25' Holding tank WA Animal containment areas None Manurelanimal excrete storage areas None SEPARATION DISTANCES FROM SEPTICIHOLDING TANK ON LOT TO: Building foundation >S Property line>S Absorption field >5' Water main 2110' Water service line 2110 Surface water >100, Wells on adjacent lots >100' SEPARATION DISTANCE FROM ABSORPTION FIELD ON LOT TO: Property line >10' Building foundation >10' Water main >10' Water Service line >70' Surface water >100' Driveway, parkingtvehicie storage >2S Curtain drain None Noted Wells on adjacent lots >100! F. COMMENTS - 44 G. ENGINEER'S CERTIFICATION �+rVl4 •'�J;f t, N 1 cer* that I have determined through field inspections and •.9 y * • ,49-TH , • *�0 • 10 review of Municipal records that the above systems are in P 1 s ...% .. conformance with MOA COSA guidelines In effect on this date. �.... ..�•00 � ^ •••••••r .Mrd1a ' yO : 2t t7WDER5pry �� r Engineer's Printed Name Michael E. Anderson, P.E. G��✓�E''i38� �\y= / O v Date 9182008 r,✓I �� pB!)ireeinNp` wva COSA Fee $_ Date of Payment Receipt Number, (Rev. 11/05) Waiver Fee $ Date of Payment Receipt Number Municipality of Anchorage r , `•� Development Services Department ./ Building Safety Division On -Site Water and Wastewater Program 4700 Elmore Street P.O. Box 196650 Anchorage, AK 99519-6650 www.muni.org/onsite (907)343-7904 Nitrate Advisory Certificate of On -Site Systems Approval # 80332 A Certificate of On -Site Systems Approval inspection and test of potable water was recently conducted on the well water supply on Block , Lot 1 of Forest Creek subdivision. This inspection revealed a nitrate concentration of 7.72 milligrams per liter (mg/L) was reported for the property's well water sample. The Environmental Protection Agency (EPA) has established a maximum contaminant level (MCL) of 10.0 mg/L for public drinking water systems. While private wells are not subject to this regulation, EPA standards are based on existing health information and can therefore be used to gauge the relative quality of water from private wells. Please see the attached "Nitrate Fact Sheet" for important information regarding nitrate. This advisory must be attached to all copies of the subject Certificate of On - Site Systems Approval.