Loading...
HomeMy WebLinkAboutTIMBERLANE PARK #1 BLK 4 LT 7BMunicipality of Anchorage _, Development Services Department == _ __ '. (• Building Safety Division ' \ On-Site Water 8 Wastewater Program, 4700 South Bragaw St. P.O. Box 196650 Anchorage, AK 99519-6650 www.cl.anchorage.ak.us (907) 343-7904 Page 1 of 3 On-Site Wastewater Disposal System and/or Well Inspection Report Permit Number. SW060241 PID Number. 019-152-34 Nome: Wastewater System: ■ New ❑ Upgrade RICO FERNANDEZ Address: 12140 HILLTOP DRIVE * ANCHORAGE, AK 99515 ABSORPTION FIELD Phone: No. of Bedrooms: (907) 349-9925 4 ■Deep Trench Cl Shallow Trench O Bed ONound OOther LEGAL DESCRIPTION sw R": 1.2 GPD/Sq. R Tow D.Wh nem erlelnal pee.: 9.5 MAX R Block: Lot: Subdivision: D.Wh m pro. batt— foo` "kW goer Cre..l d.Wn bwwalh OP.: 6.14 4 78 TIMBERLANE PARK #1 SEE DWG. R R Township:Range: Section: — Tel edeas ebev. «lglrwl pile'' a'wx Wgum. 51 - - SEE DWG. R R Clovis wlwn: Number al M: /bland bNw.m edr WELL: [INew ❑ Upgrade 2.5 R 1 — R Cb.whaalwn Prlwl.. A.11.0. Tow Caw To: Taw eb.orpDon ane: 626 Pp. mat.rlol: D 3034/ F-810 R R sa.R slava was« to,*:FL swan« RED DOG We swa 11/22/2006 odw P`� Dw. oww: 8�\C moot Ab. Graend: d lin s.t Arces" TANK til R R SEPARATION DISTANCES ■Septic C! Holding 13S.T.E.P. OOther io Septic Absorption Lift Holding abr¢/Prlvat.'"'"''° CHORAGE TANK " 1250 From Tank Field Station Tank S.w« Ude Water line 10'+ 10'+ — — — yw«ly. STEEL NwMw of aanipart^wnt•: 2 Surface Water 100'+ 100'+ — — — LIFT STATION Lot Line 5'+ 10'+ — — — s4. In paean: bk.Maatwr. en M..l ul: ell W: wpn will« alarm al: Foundation 5'+ 10'+ — — — pump tdaY. Electrical krp.enod p«fomwd by. Curtain Drain NONE KNOWN BENCH MARK Remarks: leeelbn ane D.walpuon: TOP OF CMU NEAR POINT "A" A.""dd E" soon' 101.31 R ENGINEER? SEAL Inspections performed by: GEG, Ltd. Dates: 1st 11/22/2006 11/22/2006 0000004 P ���4p 2nd .. 3rd 11/22/2006 ..F 4A, • sr00o Development Services Department Approval 0�'�: •.:•.� Reviewed and approved by: Date: D Je ..• •••• •• nese•••: • 0 rr A. �Q e CE-79P3 4KOdPro Date: 2-A 0 Reviewed and approved by: #ell ressja0aco (R.r. 4/06) 1000��p00 PERMITNUMBER: AS -BUILT DRAWING PARCEL NUMBER: SW060241 019-11 52-34 SW0 WATER UNE •;•�'•;. •�• A B C '. STI 1 19.1 1 50.7 28.7 „• �.. ••;; ' •• •• ST2 18.4 50.1 36.6 + •' •" DBLI 18.5 49.7 41.2 + ••" .y OBL2 19.7 50.2 43.9 4 ' • ' COt 22.2 51.7 47.3'�•��• MTI 27.8 56.0 94.1 C t� "•�'; ��. CO2 65.4 81.7 96.0 MT2 61.3 86.1 53.0 NEW 4 BEDROOM HOUSE FCO I B 2 1 NEW 1250 GA2 n SEPTIC TANI I JK 2DRAINFIFIELD Ld2 TM,� ALTERNATE SITE O y 5 E: QS= oc60� � o o OF 4p �4 GARNESS ENGINEERING GROUP, Ltd. pe'?' 4..°V, CONSULTANTS & GENERAL CONTRACTORS ' )AI L 1N000 W W. AlllC 101 • M9QIIILL M( M�°l • A1011C 00.11-11T • 14l (�01}WJ]H • gSRL �.pn•�p�wKow O PREPARED FOR: PHONE NUMBER: PACED 3OQQBY: rCE-. Gar ess: RICO FERNANDEZ 349-9925 2 OF 000 LEGAL DESCRIPTION: DRAWN B F.M. 01.��.•' q�POG '1��5 TIMBERLANE PARK f1; LOT 7B. BLOCK 4 �o ppOOQODOO�d�o DATE. TWE OF WORK: AS -BUILT FOR NEW SEPTIC SYSTEM 12/5/2006 (Rwv 01M) NUMBER: PARCEL NUMBER: PERMrTSW0 AS -BUILT DRAWING I SW060241 019-11 52-34 FINAL GRADE - 101.39 STI 512 TOP OF TANK TOP OF TANK AT INLET 97.31 AT OUTLET 97.31 NEW 1250 GALLON INVERT of BUNG SEPTIC TANK INVERT OF BUNG AT INLET - 96.70 AT OUTLET - 96.53 GRADE - 100.26-100.81 ORIGINAL GRADE 99.4Z-\ I O HIGHEST POINT I I' / FILTER FABRIC �\�I n INVERT OF PIPE 96.06 M OF - 89.92 RELATIVE ELEVATION OF BOTTOM OF TESTHOLE - 83.92 (NO H20) - .. ...-... _. - __ _.. . -. GARNESS ENGINEERING GROUP, Ltd. CONSULTANTS & GENERAL CONTRACTORS 3NI L 1110011 11010. f 101 . NOOiuOL NI M • ATOM[ (901)"73 In • TNI (10I)3,D o • �U30C W.gyn. wMYymi PREPARED FOR: PHONE NUMBER: PAGE NUMBER: 1 RICO FERNANDEZ 349-9925 3 OF 3 LEGAL DESCRIPTION: DRAWN BY: TIMBERLANE PARK #1: LOT 7B, BLOCK -4 B.F.M. DATE: TYPE OF WORK: 12151200 PROFILE DRAWING FOR NEW SEPTIC SYSTEM (RWAIX5) MUNICIPALITY OF ANCHORAGE Development Services Department On -Site Water d Wastewater Program 4700 South Bragaw Street P.O. Box 196650, Anchorage, AK 99519-6650 (907) 343-7904 ON-SITE WASTEWATER DISPOSAL SYSTEM PERMIT Initial Date Issued: Aug 04, 2006 Expiration Date: Aug 04, 2007 Permit Number: SWO60241 Parcel ID: 019-152-34 Legal Description: TIMBERLANE PARK #1 BLOCK 4 LOT 7B Design Engineer: 0855 GARNESS ENGINEERING GROW Site Address: 12140 HILLTOP DRIVE Owner Name: RICO FERNANDEZ Lot Size: 80150 SO. FT. Owner Address: 12140 HILLTOP DRIVE Total Bedrooms: 4 Permit Bedrooms: 4 ANCHORAGE. AK 99515 - This permit is for the construction of: ❑✓ Disposal Field ❑✓ Septic Tank ❑ Holding Tank ❑ Privy ❑ Private Well ❑ Water Storage All construction must be in accordance with: 1. The attached approved design. 2. All requirements specked in Anchorage Municipal Code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72 ) and Drinking Water Regulations (18AAC80 ). 3, The engineer must notify DSD at least 2 hours prior to each Inspection. Provide notification by calling (907)343-7904(24 hours). ( Not required for a Water Supply Permit only). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must be either: A. Open and closed on the same day. B. Covered, sealed, and heated to prevent freezing. Received By: Issued By. Date: �%L" O� Date: �� -\ Municipality of Anchorage -�` Development Services Department Building Safety Division On -Site Water & Wastewater Program 4A. • 4700 South Bragaw St. P.O. Box 196650 Anchorage, AK 99519.6650 www.ci.enchorage.ak.us (907)343-7904 ON-SITE SEWER/WELL PERMIT APPLICATION FOR A SINGLE FAMILY DWELLING Parcel I.D. m tl-- _t -5A-34 Property owner(s) RICO FERNANDEZ Day phone 349-9925 Mailing address 1 140 HILLTOP DRIVE • ANCHORAGE. AK 99515 Site address 12140 HILLTOP DRIVE • ANCHORAGE. AK Zip Code 99515 Legal description (Sub'd, Block & Lot ) TIMBERLANE PARK #1. LOT 7B. BLOCK 4 Legal description (Township, Section & Range) Lot Size 21! 7 Acres/Sq.Ft. THIS APPLICATION IS FOR ( ®all that apply): Absorption Field 19 Septic Tank ❑ Holding Tank ❑ Privy ❑ Private Well ❑ Water Storage ❑ Number of Bedrooms THIS APPLICATION IS AN: Initial Upgrade ❑ Renewal ❑ I certify that the above information is correct. I further certify that this application is being made for a Single Family Dwelling and is in accordance with applicable Municipal codes. GARNESS ENGINEERING GROUP, Ltd. Permit/Rush Feed➢ /e o • O �� Date of Payment: 7� %lo Receipt Number. O7G v_3/�2 (Rev. 11/05) Waiver Fees: Date of Payment: Receipt Number. GARNESS ENGINEERING GROUP, Ltd. c _-_— •=�T� -1 CONSULTANTS & GENERAL CONTRACTORS -- June June 30,2006 Municipality of Anchorage Development Service Department Building Safety Division On -Site Water & Wastewater Program P.O. Box 196650 Anchorage, Alaska 99519-6650 Ref: Proposed Septic System for Timbcrlane Park #I Subdivision, Lot 7B, Block 4 To whom it may concern: The proposed 4 bedroom house is to be served by city water and a private septic system. Two test holes where dug on the property. The drainfield will be designed around the 30 foot radius of test hole #2 which has a percolation rate of 2.67 min/inch. We are proposing that a 1250 gallon septic tank and a deep trench type drainfield be installed. Comments regarding the design are summarized as follows: 1. SOILS: See the attached log which shows the soil classifications, groundwater monitoring, and the percolation test results. 2. DRAINFIELD DESIGN: See the attached design drawing for drainfield specifications. 3. SURFACE WATERS: There are no surface waters within 100+ feet of the proposed septic system. 4. TOPOGRAPHY: As can be seen on the attached tonography site plan. the average topography in the area of the proposed drainfield is fairly flat. In short, there are no slope concerns. We are unaware of any adverse impacts this installation would have on adjacent wells or septic systems. please contact us at 337-6179. Thank you for your assistance. /1.S. NOTE: Attached is a site plan drmving, a design drawing, Avo soils logs, and a 7 page construction specification letter which are all part of the design package for this septic system. 3701 E. Tudor Road, Suite 101 • Anchorage, AK 99507 Ph: (907) 337-6179 • Fax: (907) 338-3246 4 Website: gamcssengineering.com I I i I I I . I I I I I I I I I I I I I I / I / I / I / I � I � I I TIMBERLANE PARK S/D /1 LOT 9, BLOCK 4, SERVED BY PUBLIC WATER TIMBERLANE PARK S/D /I; LOT B, BLOCK 4, r \ SERVED BY PUBLIC WATER I `\ i I cr I TIC 'SPL Yx ` TIMBERLANE PARK S/D /1; n� I \ LOT 10, BLOCK 3. u SERVED BY PUBUC WATER I \ W9 I F I I [SEPTIC I uta I SERVED BY I PUBLIC WATER '�_ HILLTOP DRIVE CS—EPTIC ARA I I I PROPOSED 4 IBEOROOM HOU! M. TTM/+1 -PROPOSED SEPTIC SYSTEM (SEE DESIGN PAGE 2 OF 2) TIMBERLANEPARK S /1 LOT 6,, 4, BLOCK 4, CSEPTIC ARS / THOMASSON DRIVE \ - ------------------------- GARNESS ENGINEERING GROUP, Ltd. ;?:` —•-•- .--�W—•++• CONSULTANTS S GENERAL CONTRACTORS — • • • • 701 [. R I . w 101 . w.baq.GC, we WM) . w (907)337-4170 • FM ae13M-)]N . KBLN: PREPARED FOR: PHONE NUMBER: PACE NUMBER: ee. I RICO FERNANDEZ 907-349-9925 1 OF 2 LEGAL DESCRIPTION: DRAWN BY: TIMBERLANE PARK #1: LOT 7. BLOCK 4 1 K.D.W./J.N.T. TYPE OF WORK: SITE PLAN FOR PROPOSED SEPTIC SYSTEM (Rev 01105) 6/30/06 I I OF BEDROOMS:4 PER DAY (GPD): 600 ION RATE/S: 2.67 MIN./INCH D APPUCATON RATE: 1.2 DRAINFIELD SOTT.: 500 AINF MAXIMUM DEPTH:9.5 FEET WIDTH: 2.5 FEET LENGTH:45 FEET M.O.A. APPROVED SAND FILTER:N/A EFFECTTVE:6 FEET REDUCTION FACTOR: N/A ACTUAL SORT.: 540 LETTER THAT PERTAINS TO THIS DESIGN. TO OBTAIN A COPY OF THE LETTER CONTACT CEG. BY PROCEEDING FORWARD WITH THIS INSTALLATION, THE ENGINEER, WELL DRILLER, CONTRACTOR AND PROPERTY OWNER AGREE THAT THEY HAVE READ THESE SPECIFICATIONS AND AGREE TO ACCEPT THE TERMS AND I PROPOSED I •i ���•• WATER UNE •: ". PROPOSED FOUR •.7 :;• �/ BEDROOM HOUSE / PROPOSED 1250 GALLON SEPTIC TAI INSTALL FOUNDATION CLEANOUT CO INSTALL DOUBLE CLEANOUTS II II + I I PROPOSED / DRAINFIELD _J CO MT PROPOSED ALTERNATE SITE / + THII GARNESS ENGINEERING GROUP, Ltd. CONSULTANTS 6 GENERAL CON •••• •• .• ..... .••••*• ]MI C TIOOR IIO.D. LIR 101 • NOORMr M( "W7 • FIdS (107J=J li 0 Mi ("7)M -N" OCB4I[: �w.pn�r.pN.wYFOM� O PREPARED FOR: PHONE NUMBER: PACE NUMBER: 0 ••• ••••••• RICO FERNANDEZ 907-727-3794 2 OF 2 Q .Je A. ess:• LEGAL DESCRIPTION: DRAWN BY: UO v 79 `SpQ TIMSERLANE PARK S/D; LOT 7B. BLOCK 4 K.D.W./J.N.T. •!<,(10. e4o e F o TYPE OF WORK: DATE: ���dfrOfesS'W'0\ DESIGN DRAWING FOR SEPTIC PERMIT 6/30/06 (R..OL05) ALASKA NNIXrER & NNASTE AVXrE4 R CONSULTANTS.INC. _ nwn.nn .....n w....w wn w ............ nw ... w...... -------- w.n.. - w... '--- ..��..w LEGAL DESCRIPTION: TIMBERLANE PARK SUBDIVISION A1; LOT 7, BLOCK 4 PERFORMED FOR: RICO FERNANDEZ DATE: 4/8/2003 DEPT] ____ ORGANICS feet TEST HOLE 1 1 GM/SM LOOSER w/ DEPTH DEPTH TO GROUNDWATER DATE DRY 4/8/2003 DRY 4/15/2003 4:52 — 6- 1 I 2 4:54 1 0. 6' 3 4:54 , 6- 1GW i ; \ \ 3 •. 6- i i I TM/2+ — 6. ; 6 5:00 IIIIIIIIIML 0' 6' 7 5:00 I i ; — GM ; ; SITE PLAN CL 6' 9 5:03 10-100' 6' — 10 5:06 H/NHS 0'1 • 11 5:06 — 6' 1 — 12 5:09 3 IIIIIIIII 6' MH _ II!�l,4li�l,�ll • SC GM/SM LOOSER w/ DEPTH DEPTH TO GROUNDWATER DATE DRY 4/8/2003 DRY 4/15/2003 4:52 — 6- 1 I DATE READING t � / WATER LEVEL READING NET DROP (INCHES) 4/9/2003 1 4:52 — 6- 1 I 2 4:54 1 0. 6' 3 4:54 , 6- i I i ; \ \ 3 0' 6- i i I TM/2+ — 6. ; 6 5:00 I 7H/1* 0' 6' 7 5:00 I i ; — I i I ; ; SITE PLAN 0' 6' 9 5:03 10-100' DATE READING CLOCK TIME NET TIME (MINUTES) WATER LEVEL READING NET DROP (INCHES) 4/9/2003 1 4:52 — 6- — 2 4:54 2 0. 6' 3 4:54 — 6- — 4 4:57 3 0' 6- 5 4:57 — 6. — 6 5:00 3 0' 6' 7 5:00 — 6' — 8 5:03 3 0' 6' 9 5:03 — 6' — 10 5:06 3 0'1 6' 11 5:06 — 6' 1 — 12 5:09 3 0' 1 6' 19 PERCOLATION RATE <1 (MIN./INCH) PERC. HOLE DIA. 6 (INCHES) TEST RUN BETWEEN 5.0 FT. AND 5.5 FT. 20 A FOUR HOUR PRESOAK WAS PERFORMED: ❑ YES NO SOILS LOGGED BY: JODY MAUS PERCOLATION TEST PERFORMED BY: MATT FISHER PERFORMED BY AKWWC, INC. I, JEFFREY A. GARNESS, CERTIFY THAT THIS AS ERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE: G W ALASKA NNIXrLR & NVASTL'NWAT M CONSULTANTS. INC. IZPUIL. LUy — rcr%V ULNrrUN IL,311 LEGAL DESCRIPTION: TIMSERLANE PARK SUBDMSION #1; LOT 7, BLOCK 4 PERFORMED FOR: RICO FERNANDEZ DATE: 4/8/2003 DEPTH ORGANICS (feet) --— TEST HOLE 1 tSOIL I � NET TIME (MINUTES) WATER LEVEL READING CLAS I ICATIO 4/19/2003 E 4:43 1 I ; � i 1GW 2 ,. 10 I 3 3/4" , , 111111111ML — 6" — 4 5:05 TRi2 2 1/4" 3 3/4" 1 5 5:06 j I�111'GM H,NN� CL TM11+ i 5:16 10 1 i , ; • 1 t I ; FsITE PLAN 6" — 8 5:26 10 2 1/4- 3 3/4" II1111111MH 5:27 — 6- GM// ////.CHSM 10 2 1/4- 3 3/4- 11 (CO — 6" — 12 5:47 10 X OHSC 7- 8- 9— lo- 11 891011 GM/SM 12 LOOSER w/ DEPTH 13- 14- 16- 17- 18--4 314161718 DEPTH TO DATE GROUNDWATER DRY 4/8/2003 DRY 4/15/2003 DATE I � NET TIME (MINUTES) WATER LEVEL READING NET DROP (INCHES) 4/19/2003 E 4:43 1 I ; � 1 1 2 4:53 10 I 3 3/4" , , 4:55 — 6" — 4 5:05 TRi2 2 1/4" 3 3/4" 5 5:06 — I — TM11+ i 5:16 10 1 i , ; 1 t I ; FsITE PLAN 6" — 8 DATE READING CLOCK TIME NET TIME (MINUTES) WATER LEVEL READING NET DROP (INCHES) 4/19/2003 1 4:43 — 6" — 2 4:53 10 2 1 4" 3 3/4" 3 4:55 — 6" — 4 5:05 10 2 1/4" 3 3/4" 5 5:06 — 6" — 6 5:16 10 2 1/4- 3 3/4" 7 5:16 — 6" — 8 5:26 10 2 1/4- 3 3/4" 9 5:27 — 6- 10 5:37 10 2 1/4- 3 3/4- 11 5:37 — 6" — 12 5:47 10 2 1/4 19 I PERCOLATION RATE 2.67 (MIN./INCH) PERC. HOLE DIA. 6 (INCHES) TEST RUN BETWEEN 5.0 FT. AND 5.5 FT. 20 A FOUR HOUR PRESOAK WAS PERFORMED: N YES ❑ NO SOILS LOGGED BY: JODY MAUS PERCOLATION TEST PERFORMED BY: MATT FISHER COMMENTS: PERFORMED BY AKWWC, INC. I, JEFFREY A. GARNESS, CERTIFY THAT THIS AS PERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE: 3a Cop - No NP.ny. I 3- \ � •'. - \ P Lot 10 Lot 9 I � • .Eormrr.t S � .Rvc.o. '..... 009Hy�b� ler Ur Eeummt�l Y. LOT _-A __.__ _ .tt. '1 "-'v_�'_b LI 0•�hE ' S1T410 E 61.611 NSS-Z33W NVV1'00"r 69.211 ,37.13 Z.�Ea..mml Fa9.o x' co, - No M~g. T" ;..._._.... ~ •.,•'.Gr -__ _ _ 5697T10'M 171.01'(Y) [AST 171.00'(Rl) f�-. _ 5, �1,•� $ Lot 6 6 8 I 410047.3 sfftt 8 = N I � Lot 6 I I §�J--10• UE .. I Co..mmi I �neLrtil�� HTC R j 1 L6 LEM S.1 3 1/4' ALmY.+.. Cop l7B L6 . 3 1 r 1 N 6.10=1_111 umumr.f m 2 1/x•.30• e. 6. uPN�P3..w.1 /I Row 0 pa Ftu.N 911; Gouts % Ror AMn. pb LS 7e» ///17 TtE j L=am m.as(o n x00) �Ep.r..ml N69'19•4119' 170.91'(Y) N6 N V EAST 170.00*(RI)EAST ln.60'(Rt) b BASIS OF _BEARING 06.60'(Y) _-- EAST 6603.q'!Rt) • Municipality of Anc rage o 1 M5 R' Ax On -Site Water and Wastewater Progr r tct-iat studkiii- < (907)343-7904 S A 1 9 7 $Certificate of On -Site Systems Approval //�� l��3 1 Parcel 1. D. 019-152- Expiration Date: I l DJ 1. GENERAL INFORMATION Complete legal description Timberlane Park #1, Block 4, Lot 713 Location (site address) 12170 Hilltop Dr. Current Property owner(s) Kamsiah Fernandez Day phone Mailing address 12170 Hilltop Dr. Anchorage, AK 99515 Real Estate Agent 2. TYPE OF DWELLING: i] Single Family (w/wo ADU) ❑ Duplex ❑ Multiple Dwellings (Single Family and/or Duplex) 3. NUMBER OF BEDROOMS: 4. TYPE OF WATER SUPPLY: Individual Well Individual Water Storage Community Class Well Public Water System Waiver/Variance request S Day phone TYPE OF WASTEWATER DISPOSAL: ® No's rl Individual ❑ ❑ Holding Tank ❑ ❑ Community ❑ ® Public Sewer ❑ Received by: 011-,a4 Date: COSA to be released to the engineer, unless otherwise requested by the engineer. COSA Fee $ �5o26' Waiver Fee $ Date of Payment 10 1K Date of Payment Receipt NumberQ g4,1eG Receipt Number (l COSA# Ji�E15 'a Waiver# 5. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based on procedures outlined in the Certificate of On -Site Systems Approval Guidelines for this application, shows that the on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation. In conducting an adequacy test, I attempt to provide a thorough, conscientious engineering analysis of the system in accordance with MoA COSA guidelines and regulations. The reported results describe the performance of the system under the conditions encountered at the time of the test, and separation distances measured to readily identifiable features. The operational fife of all wells and septic systems depend on the local soil condition, ground water levels that may fluctuate during the year, and the water usage of the family being served by the system. These conditions are outside the control of the evaluator of this system. All systems eventually fail and satisfactory test results do not guarantee future performance of the system, nor do they guarantee that there are no hidden defects or encroachments. Therefore we cannot provide any warranty for future performance, nor can we estimate remaining life of the system. The content of this report is for the sole benefit of the owner listed above. Name of Firm Pannone Engineering Services LLC Address P.O. Box 100217, Anchorage Ak. 99510 Engineer's Printed Name Steven R Pannone 6. DSD SIGNATURE / System #1 Approved for `7 bedrooms System #2 Approved for bedrooms Disapproved Phone (907) 272-8218 Date 9/29/2015 Conditional approval for bedrooms, with the following stipulations: By: A jAAPj_\11 (ry V Original Certificate Data: l� Th unicipality of Anchorage Development Services Division (DSD) issues Certificates of On -Site Systems Approval (COSA) based only upon the representations given in paragraph 5 by an independent professional civil engineer registered in the State of Alaska. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. 7. ATTACHMENTS: COSA Checklist X Nitrate Advisory Septic System Advisory Arsenic Advisory Well Flow Advisory Other COSA blue sheet <, .., . If more than 1 septic system is on the lot: COSA Checklist # + of 1 Structure served by this system .Certificate of On -Site Systems Approval Checklist Legal Description: Timberlane Park #1, Block 4, Lot 7B A. WELL DATA Well type Public Date completed Total depth ft. Date of test Static water level Well production YS Parcel ID: 019-152-x, If A, B, or C provide PWSID # AWWU Well Log (Y/N) Sanitary seal (Y/N) _ Wires properly protected (Y/N) Cased to ft. FROM WELL LOG WATER SAMPLE RESULTS: ft. g.p.m. Coliform colonies/100 mL Nitrate mg/L Arsenic ug/L Date of sample: B. SEPTIC/HOLDING TANK DATA Tank Type/Material Septic/Steel Tank size 1,250 gal. Number of Compartments 2 Foundation cleanout (Y/N) Y Depression over tank (Y/N) N Casing height (above ground) in. AT INSPECTION ft. g.p.m. Collected by: Date installed _11/22/2006 Cleanouts(Y/N) Y High water alarm (Y/N) N Date of pumping 10 ` — Pumper [)"I.J A[j Wafu C. -ABSORPTION FIELD DATA Date installed 11/22/2006 Soil rating (g.p.d./ft2 or ft2/bdrm) 1.2 GPD/SF System type Deep Trench Length 51 ft. Width 2.5 . ft. Gravel below pipe 6.14 ft Total depth 9.7 ft. Eff. absorption area 626 fe Monitoring tube Y Depression over field N Date of adequacy test 9/28/2015 Results (Pass/Fail) Pass For 4 bedrooms Fluid depth in absorption field before test 37 in. Elapsed Time: 1 440 min. Final fluid depth 37 Water added 605 gal New depth 4 1 in. in. Absorption rate >= 600+ g.p.d. Any rejuvenation treatment (past 12 mo,) (Y/N & type) NO If yes, give date D. LIFT STATION Date installed Size in gallons "Pump on" level at in. "Pump off' level at Datum Cycles tested E. SEPARATION DISTANCES WELL ON LOT TO: Manhole/Access (Y/N) in. High water alarm level at _ Meets alarm & circuit requirements? Septic tank/lift station on lot On adjacent lots Absorption field on lot On adjacent lots Public sewer main Public sewer manhole/cleanout Sewer /septic service line Holding tank Animal containment areas Manure/animal excrete storage areas SEPTIC/HOLDING TANK ON LOT TO: Building foundation 5+ Property line 5+ Water main 10+ rb Water service line 10+ Wells on adjacent lots C.00+ ABSORPTION FIELD ON LOT TO: Property line 10+ Building foundation 10+ Water Service line 10+ Surface water 100+ Curtain drain 50+ Wells on adjacent Iots4_00+ F. COMMENTS G. ENGINEER'S CERTIFICATION I certify that f have determined through field_ inspections and review of Municipal records that the above systems are in conformance with MOA COSA guidelines in effect on this date. Engineer's Printed Name Steven R. Pannone Date 9/29/2015 COSA.canary sheet 2-&15.doc Absorption field 5+ Surface water 100+ Water main 10+ Driveway, parking/vehicle storage 10+ ... M;Y n V.,Ao* inane Lot 7A S 2 0 � 177 s11, bo, \o N 24. ^G09 16.0 r 8 `,lz Asphalt J M v MCO M o 32.0 ° I ° ° N I o'aa 2 Story Frame HousJ o P4 I 'N I Lot 7B I I I L---------------- N89°59'41 "W 170.01 0 uc THOMASSON DRIVE — EASEMENTS OF RECORD, OTHER THAN THOSE SHOWN ON THE RECORDED PLATARE NOT SHOWN HEREON. FB 15-9, pg 63-64 8425V �10' T &Easem;nt Lot 8 SCALE: V= 50' OF 49th 0410 �` 1000 i.:... >/. Fred Walatko 3255 -S ` I �rE5510NP� � AS -BUILT NO CORNERS SET THIS DATE 1 hereby certify that I have performed a Mortgagee's inspection of the following described property: LOT 7B, BLOCK 4, TIMBERLANE PARK SUBDIVISION No 1 Anchorage Recording District, Alaska, and that the Improvements situated thereon are within the property lines and do not overlap or encroach on the property tying adjacent thereto, that no improvements on the property lying adjacent thereto encroach on the premises in question and that there are no roadways, transmission lines or other visible easements on said property except as indicated hereon. Dated at Anchorage, Alaska 1st dayof October ,2816. FRED WALATKA & ASSOCIATES BE(987-248-1868) Engineers and Surveyors