Lot 107
#051-144-28
Inspection report not approved.
Not Eligible for COSA
T15N RIW
Sec 9
Lot 107
#051-144-28
Municipality of Anchorage
Development Services Department
Building Safety Division
Onsite Water and Wastewater Program, 4700 Bragaw St.
P.O. Box 196650 Anchorage, AK 99519-6650 Page 1 of 2
www.ci.anchorage.ak.us (907) 343-7904
ON-SITE WASTEWATER DISPOSAL SYSTEM AND/OR WELL INSPECTION REPORT
Permit Number: SW060378
PID Number: 051.144-28
Name.
BRUCE MILLER
Wastewater System: ® New ® Upgrade
Address:
13140 MIDORI DRIVE
ABSORPTION FIELD
Phone:
Number of Bedrooms.
❑ Deep Trench ❑ Shallow Trench ❑ Bed ❑ Mound D Other:
LEGAL DESCRIPTION
Soil Rating
Total Depth from original grade
0.5 GPDfFI'
2' TO SAND Ft.
Block: Lot: Subdivision:
Depth to pipe bottom from original grede:
Gravel depth beneath pipe:
107
T15N R1W SEC 9
0.7 feet above
0.5
Ft.
Ft.
Township: Range:
Section:
Fill addetl above onglnal gratle'
Gravel Length:
15N 2W
25
3.5 FI.
75 Ft.
Welt, ® New
Upgrade
Gravel witllh:
NumbDistance between Distanbetween lines.
95 Fl.
3 5 Ft.
Classification (Private, A. B, C): Total Depth:
PRIVATE
Cased to:
Total absorption area:
Pipe Material:
280
Ft. 73 FL
1125 Ft=
ASTM 3034
Driller.
M&W
Date Drilled
5/512007
Static Water Level.
103
Installer
Dale Installed'
Ft.
Yield
Pump Set al:Casing
Height Above Ground:
0.5 GPM
Ft.
3 Ft,
TANK
SEPARATION DISTANCES
® Septic ❑ Holding ® S.T.E.P. ❑ Other:
To
Septic
Absorption
Lift
Manufactures
capacity:
From
Tank
Field
Station
ANCHORAGE TANK
1250 cal.
well
Material:
STEEL
Number of Compartments.
3
Surface Water
+100'
+100'
+100'LIFT
Nu,b
STATION
Lot Line
+5'
+1Q'
+5'
Size:
Manufacturer1250
ORENCO
Gal
r
+5
r
+5
t'Pump
+10
on' level at:
'Pump oft' level at
High water alarm atFcundatlon
n.
in.
in.
Curtain Drain
rr
+50
+50
IPump
+50
Make&Model
Electncal Inspections performed by
OSI P20
Remarks:
EXISTING WELLS DECOMISSIONED,
BENCH MARK
-
Location and Oescnplion:
BOTTOM OF SIDING AT SW HOUSE CORNER
_ Assumed Elevation:
100.00 FL
Inspections performed by: ERES
Dates: 1" TLiti1L o7
,.... ,..... q�
z rid
7u&)6 07
Q% •.t��
TN
Development Services Department Approval°
Conditional Approval
Date:
.... _...
,
'o
i1 CHRISTOPHER R. W00
Reviewed and approved by:
Date:
.•••pypt-o�
(Ruv. NM)
-
Permit No. SWO60378
Page 2 of 2
Municipality of Anchorage
DEVELOPMENT SERVICES DEPARTMENT
ON—SITE WATER & WASTEWATER PROGRAM
4700 SOUTH BRAGAW STREET P.O. BOX 196650, ANCHORAGE, AK 99519-6650
On—Site Wastewater Disposal System and/or Well Inspection Report
Legal Description: T15N, R1W, SEC.9 LOT 107 051-144-28
J D TTS.
8/6/2007 %
WELL /
SWING TIES
SHED
C 442' 628'
NJ ,'CRAPE'
STNG
LOT 107
— CLEANOUT
- WELL
T
ELEVATIONS
N89'56'31"E
(NOT TO SCALE)
❑RIC
LEV
MT -1
FILL MT -2
r-
ION
SULe1250
FZ5'
94'7AND
73
"M
ASSUMED
97.3
96.6
sHE
NEW 1250 GAL
S.T.E.P. TANK
4TION = 100'
330.13
ENGINEER'S SEAL
�! OF A
TH-1 0Com...... .... q
CHRISTOPHER R. WOOQ
CE -10387
BEDROCK 1
H w
ln N
(n z
LL1 3
L
LL z
u
M -W ,lob No.: 07-118
M -W Drilling, Inc.
*P.O. Box 110378 *Anchorage, AK 99511♦
♦ 907-345-4000 • 907-345-3287 Fax
Permit No.
Groundwater Well As -Built & Log
♦ Well Owner: Bruce Miller ♦ Use of Well: Private
*LegalDes 2344 Steffes
North Birchwood
Construction
*Hole Depth: 280' ♦Casing Size: 6 5/8" ♦Cased to: 73.09 +Material: A 53 Steel
♦Drill Method: Air Rotary
Perf.
♦ Wefl Completion- Open end _Screen Per _Method.•
*Screen/Perforation description:
♦ Orout Notes: 3 Sacks No. 8 Bentonite Granules Dry Grouted
♦Well Development: Method: Air surge Notes:
*Static water level (SWL) 102.7 (below) top of casing
♦ Well yield test at 1/2 gallons per minute (GPM) I hours)
with 100% of drawdown (DD) from static level (SWL).
*Medhod: Air Lift
♦Dateofeanfledon: 05/05/07 *Pampinstall.
32ss3
Job No.: 07-115
M -W Drilling, Inc.
*P.O. Box 110378+ Anchorage, AK 99511♦
♦907-345-4000 ♦ 907-345-3287 Fax♦
Well Decommissioning Report
*Well Owner: Bruce Miller *Use of Well:
♦Legal Description & Well Id. No. (if applicable): 2344 Steffes, North Birchwood, AK
T15N, R1W, Sec. 9. Lot 107
Original Construction
Domestic
♦Hole Depth: ♦Casing Size: *Cased To: ♦Material: A 53 Steel
♦Casing ID: ♦Static Level: (from ground surface)
♦ Well Bottom: Open end Screen Perforated
• Material:
♦ Material:
♦ Material:
Decommission Materials
3�4" Hole Plug - Bentonite Grout
Quantity: 10 Bags
Quantity:
Quantity:
♦ Notes: This was a hand dug well located at back left corner of house. Well was
3'h square and caved into 8' below grade. We placed hole plug to create a 1'thick
♦ Date ofcompletion: 11/20/07 *Pump Pulled:
uecommisslon Log
Depth in feet from
ground level. Details of sealing and back -filling materials.
TO 7 Used 3/4" hole DluE to make 1' seal on toD of caved in well
17x7
_WA E -E- WESTP-E-m
o.ccirici lL M -W Ddiling, Inc.
M -W Drilling, Inc.
*P.O. Box 110378+Anchorage, AK 99511♦ G
Job No.: 07-115
♦907-345-4000 ♦ 907-345-3287 Fax♦ 0
Well Decommissioning Report
♦ Well Owner: Bruce Miller ♦ Use of Well: Domestic
♦ Legal Description & Well Id. No. (if apprcabie): 2344 Steffes, North Birchwood, AK
T15N, R1W, Sec. 9. Lot 107
Original Construction
♦Hole Depth: 50, ♦Casing Size: 6" ♦Cased To: ♦Material: A53Steel
♦Casing ID: ♦Static Level: (from ground surface)
♦ Well Bottom: Open end Screen Perforated
Decommission Materials
♦ Material: 3/4" Hole Plug - Bentonite Grout Quantity: 11 Bags
♦ Material: Quantity:
♦ Material: Quantity:
♦ Notes: This was the cased well located at the back left corner of house. Filled casing with hole
hole plug and welded 1/4" cap on casing.
♦ Date of completion: 11/20/07 ♦ Pump Pulled:
Decommission Log
Depth in feet from
ground level.
Details of sealing and back -filling materials. _
0 TO 3
Cut casing below grade
3 TO 50
Fill with hole plug
.-...... -.-
TO
_..... _.-----_ -------
-- --. -- -
-
TO
TO- -----
TO
To
. .- .. .
pE E•- -
Uin�� Inc- ..
TO
en��'''�'t
TO
N6WA� No 1
- --
TO
-- -
_..
--- -------- --- -------- ---- . -------------
MUNICIPALITY OF ANCHORAGE
Development Services Department
Onsite Water a Wastewater Program
4700 South Bragaw Street
P.O. Box 196650, Anchorage, AK 99519-6650
(907) 343-7904
ON-SITE WASTEWATER DISPOSAL SYSTEM PERMIT
Upgrade
Permit Number: SWO60378
Legal Description: T1 5N R1 W SEC 9 LOT 107
Design Engineer: 0070 KND ENGINEERING
Owner Name: BRUCE MILLER
Owner Address: 13140 MIDORI DRIVE
ANCHORAGE. AK 99516-
Date Issued: Nov 28, 2006
Expiration Date: Nov 28, 2007
ParcelID: 051-144-28
Site Address: 20334 STEFFES STREET
Lot Size: 108900 SO. FT.
Total Bedrooms: 3 Permit Bedrooms: 3
This permit is for the construction of:
Q Disposal Field ❑✓ Septic Tank ❑ Holding Tank ❑ Privy ❑ Private Well ❑ Water Storage
All construction must be in accordance with:
1. The attached approved design.
2. All requirements specified in Anchorage Municipal Code Chapters 15.55 and 15.65 and the State of Alaska
Wastewater Disposal Regulations (18AAC72 ) and Drinking Water Regulations ( 18AAC80 ).
3. The engineer must notify DSD at least 2 hours prior to each inspection. Provide notification by calling
(907) 343-7904 (24 hours). ( Not required for a Water Supply Permit only).
4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather
must be either: A. Open and closed on the same day.
B. Covered, sealed, and heated to prevent freezing.
5. The following special provisions.
-THE EXISTING WELLS NEED TO BE PERMANENTLY DECOMMISSIONED PER AMC 15.55.060J, PRIOR TO
INSTALLATION OF NEW SEPTIC SYSTEM. THE DECOMMISSIONED WELLS DOCUMENTATION NEEDS TO
BE SUBMITTED WITH INSPECTION REPORT.
Received By.
Date: 3t
Issued By a&Date: !r
�I°
\ Municipality of Anchorage
• --1 Development Services Department
Building Safety Division
On -Site Water and Wastewater Program
4700 Bragaw Street ' " "'
P.O. Box 196650
Anchorage, Alaska 99519-6650
www.muni.org/onsite
(907)343-7904
ON-SITE SEWER/WELL PERMIT APPLICATION
FOR A SINGLE FAMILY DWELLING
Parcel I.D. 051-144-28
Property owner(s) BRUCE & CAROL MILLER Day phone345-2096
Mailing address 13140 MIDORI DR., ANCHORAGE AK Zip Code 99516
Site address 20334 STEFFES, CHUGIAK, AK Zip Code 99567
Legal description (Sub'd., Block & Lot)
Legal description (Township, Range & Section) T15N R1 W SEC 9 LOT 107
Lot Size 108900 Sq. Ft.
THIS APPLICATION IS FOR (® all that apply):
Absorption Field
Septic Tank
Holding Tank
Privy
Private Well
Water Storage
Number of Bedrooms 3
THIS APPLICATION IS AN:
Initial
El
Upgrade
Renewal
❑
I certify that the above information is correct. I further certify that this application is being made for a
Single Family Dwelling and is in accordance with applicable Municipal Codes,
KND ENGINEERING, INC. (WELL FEE PAID 10/25/06)
(Signature of property owner or authorized agent)
Permit/Rush Fees: $460.00 Waiver Fees: /7<�
Date of Payment: 1142JOU Date of Payment: �Z> la'
�1—
ReceiptNumber. gl�Q 1J$ Receipt Number. DQ'l �r1
(Rev. 11/05)
(Oft� e-'�
Municipality of Anchorage
• Development Services Department
Building Safety Division
On -Site Water and Wastewater Program
4700 Bragaw Street
P.O. Box 196650
Anchorage, AK 99519-6650
www.muni.org/onsite
(907)343-7904
ON-SITE SEPTIC/WELL PERMIT APPLICATION
FOR A SINGLE FAMILY DWELLING
Parcel I.D. - 8'
Property owner(s)•�iuce /12'//� G'a o/ /� -/Day phone 3S/s=,2C9�
Mailing address 13/_5 ,�iu2,, 7 Q Zip Code
Site address Zip Code 956-6 '7
Legal description (Sub'd, Block & Lot) ,( T to 7
Legal description (Township, Section &Range) T/r R /W
Lot Size /09>0o Sq. Ft. Number of Bedrooms c>�
nED
THIS APPLICATION IS FOR (®all that apply)��6lf5 �It S AN: .
Absorption Field
❑ Initial
Septic Tank
❑ Upgrade
Holding Tank
❑ Renewal
Privy
❑
Private Well
(�
Water Storage
❑
I certify that the above information is correct. I further certify that this application is being made for a
Single Family Dwelling and is in accordance with applicable Municipal Codes.
(Signature of property owner or authorized agent)
Permit/Rush Fees: 1 /.7 � Waiver Fees:
Date of Payment: _ I012 6-106 Date of Payment:
Receipt Number: D q.78 / / Receipt Number:
(Rev. 11/05)
KN D ENGINEERING, INC.
20441 PTARMIGAN BLVD.
EAGLE RIVER. AK 99577-8736
11/FAX
November 22, 2006
Municipality of Anchorage
Development Services Department
On -Site Water & Wastewater Program
P.O. Box 196650
Anchorage, AK 99519-6650
Subject: New sewer/well permit —T15N R1W SEC 9 LOT 107
Gentlemen:
The owner has requested we proceed forward to obtain aseptic permit on the subject
lot. On November 9, 2006 one testhole was performed for the proposed system. The
results of this test are attached. The general slope of this lot is from east to west at a
grade of approximately 3-5%. The existing undocumented system has been
disconnected from the residence and abandoned in place per code. Three low
producing, nonconforming wells are to be decommissioned and a new well drilled in
the northeast portion of the lot.
We have designed our system utilizing the existing testhole that was excavated for the
existing 3 -bedroom house. The lot will be served by an individual well, located on the
northern portion of the lot. We propose to install two 5' wide shallow trenches. Water
was encountered during the excavation at 6, and during monitoring at 5'.
There are no public or private wells within 200' of our proposed system location except
as noted. There is no surface water within 100' of the proposed system and there are no
known curtain drains within 50'. We do not expect there to be any adverse effect on
adjacent lots by the development of this system.
If you have any questions, please contact me at 696-6111/FAX 696-8111.
Respectfully submitted,
ZED Engineering, Inc.
KennethM. D , P.EIK
Attachments: On -Site Well and Sewer Application
Wastewater Absorption System Details/Site Plan
Soils Log/ Percolation Test
Owner/ Contractor Specs
(WELL & WASTEWATER DISP❑SAL SYSTEM DETAILS/SITE PLAN
T15N, R1W, SEC 9, SM, LOT 107
169011
TIC
m
NO PUBLIC WELLS WITHIN 2W Or
PROPOSED SYSTEM.
NO PRIVATE WELLS WITHIN 2W Or
PROPOSED SYSTEM EXCEPT AS NOTED.
NO SEPTIC SYSTEMS WITHIN RW Or
PROPOSED WELL EXCEPT AS NOTED.
or Ir OF ALq 1 �
.77
%
tAlf. ncnncCE�T nl uWrT /
(w L.wE) /
LOT Tm
W
DESIGN DETAILS
3 BDRM X 150 GPD = 450 GPD
450 GPD/0.6 GPD PER SO. FT. (17 MIN/IN.)= 750 SQ. FT
(750/ 5' (W)) x I(RF) (0.5' GRAVEL) - 150 FT. TRENCH
USE 2 TRENCHES - 75' (L) X 5' (W) X 0.5' (D)
Total depth of system is 2' from original grade.
Total depth of gravel below distribution pipe Is 0.5' .
1. EXCAVATE TOP 2' FROM ORIGINAL GRADE
2. INSTALL 1'* OF MOA APPROVED SAND
3. INSTALL 0.5' SEWER ROCK
PRESSURIZED DISTRIBUTION SYSTEM HOLE SPACING DESIGN
1. RESIDUAL HEAD = 5'
2. HOLE SIZE = 3/16' = 1.00 GAL. PER HOLE 2 30 PSI
3. 30 GALS (PUMP DELIVERY)/1.00 GALS/HOLE = 30 HOLES
4. 150 LF LATERAL/30 HOLES = 5' SPACING PER HOLE
5. ALL HOLES SHALL HAVE CAPS INSTALLED PER MANUFACTURES SPECS
NOTES:
1. INSTALL 1250 GALLON STEP tL INSULATE IF ( 4' COVER
2. INSULATE TRENCHES WITH 2' HD BURIAL FOAM.
3. CONTRACTOR WILL ENSURE MINIMUM 2% SLOPE INTO SEPTIC TANK.
4. ADDITIONAL FILL WILL BE ADDED OVER SYSTEM TO ACHIEVE
MIN. 3' COVER IF REQUIRED.
5. CONTRACTOR WILL ENSURE ALL SEPARATIONS TO ADJACENT
WELLS, SEPTICS, LOT LINES, FOUNDATIONS AND ALL OTHER SETBACKS
PREPARED FOR:
BRUCE MILLER
13140 MIDORI DR.
ANCHORAGE, AK 99516
(907)345-2096
nEU) BOOKS COMPVTM
11OURD�Xd R tN ORA"' km
;T- OcCMED: KMD
NSRXr.. DAT[: 11/18
<
DNc. nr. DRna NW1258
MCN/ nE: rua_*oTc«. •'DR "': 06-120
Scale: 1'= 100'
PAGE 1 OF 3
MID ENGINEERING, INC.
20441 PTARMIGAN BLVD.
EAGLE RIVER, AK 99577-8736
(907)088-3793
gi
J
s
�
I�I
W
DESIGN DETAILS
3 BDRM X 150 GPD = 450 GPD
450 GPD/0.6 GPD PER SO. FT. (17 MIN/IN.)= 750 SQ. FT
(750/ 5' (W)) x I(RF) (0.5' GRAVEL) - 150 FT. TRENCH
USE 2 TRENCHES - 75' (L) X 5' (W) X 0.5' (D)
Total depth of system is 2' from original grade.
Total depth of gravel below distribution pipe Is 0.5' .
1. EXCAVATE TOP 2' FROM ORIGINAL GRADE
2. INSTALL 1'* OF MOA APPROVED SAND
3. INSTALL 0.5' SEWER ROCK
PRESSURIZED DISTRIBUTION SYSTEM HOLE SPACING DESIGN
1. RESIDUAL HEAD = 5'
2. HOLE SIZE = 3/16' = 1.00 GAL. PER HOLE 2 30 PSI
3. 30 GALS (PUMP DELIVERY)/1.00 GALS/HOLE = 30 HOLES
4. 150 LF LATERAL/30 HOLES = 5' SPACING PER HOLE
5. ALL HOLES SHALL HAVE CAPS INSTALLED PER MANUFACTURES SPECS
NOTES:
1. INSTALL 1250 GALLON STEP tL INSULATE IF ( 4' COVER
2. INSULATE TRENCHES WITH 2' HD BURIAL FOAM.
3. CONTRACTOR WILL ENSURE MINIMUM 2% SLOPE INTO SEPTIC TANK.
4. ADDITIONAL FILL WILL BE ADDED OVER SYSTEM TO ACHIEVE
MIN. 3' COVER IF REQUIRED.
5. CONTRACTOR WILL ENSURE ALL SEPARATIONS TO ADJACENT
WELLS, SEPTICS, LOT LINES, FOUNDATIONS AND ALL OTHER SETBACKS
PREPARED FOR:
BRUCE MILLER
13140 MIDORI DR.
ANCHORAGE, AK 99516
(907)345-2096
nEU) BOOKS COMPVTM
11OURD�Xd R tN ORA"' km
;T- OcCMED: KMD
NSRXr.. DAT[: 11/18
<
DNc. nr. DRna NW1258
MCN/ nE: rua_*oTc«. •'DR "': 06-120
Scale: 1'= 100'
PAGE 1 OF 3
MID ENGINEERING, INC.
20441 PTARMIGAN BLVD.
EAGLE RIVER, AK 99577-8736
(907)088-3793
WASTEWATER DISPOSAL SYSTEM DETAILS
T15N, R1W, SEC 9, SM, LOT 107
aPRiPOSED
6 PUBLIC USE LOT EASEMENT 107 � � - � -
EXISTING S PTIC
K N p FIELD A.I.P —11/9
1 O� P2.5'
:C0
SHED
FLAG WELL RADII PRIOR N .0
TO CONST. N N
CRA L
CONSTRUCT TRENCHES22.5' 5.0' D/
PARALLEL TO SLOPE ~ EXISTING
CONTOURS. a i
u 3 BDRM
zn HOUSE o i7
SWING—TIE CHART 4" SOLID PIPE AT
2% MAX GRADE — A 4.' 83.0'
A—C=18.62
B—C=28.35 1250 GAL STEP FCO /
A—D=20.97 SEPTIC ST
B—D=46.17 �1-49. F MT MT C
A—E=93.98
8—E=103.50 SHED
A—F=26.54 / �W
B—F=60.09 11.9'
A—G=95.60 TH06-01
B—G=110.64 `
CONSTRUCT TRENCHES \I 3 WE LS TOE
MIN. OF 5' AWAY FROM DECO MISSI E
TH LOCATION. 10 1 1/4" SOLID
m m
PVC PIPE
V_4% z cZi 1_4%
�
MAX DEPTH O.G. 1' �'_ '�7� ,AO
N /%
A.I.P. =Abandon In Place Per �A
Code & Or Install Diverter MT MT E
tm�
OF ALgs PREPARED FOR:
��.' '• 1 BRUCE MILLER
13140 MIDORI DR. $Cale: 1'= 30�
ANCHORAGE. AK 99516
(907)345-2096 PAGE 2 OF 3
KENN H M. DUFF FIELD BOOKS CoWun
/,'�'•. CE -7118 � m eawmr. SCHULLER M DRAW. krnd END ENGINEERING, INC.
'URNO 0"ECKM.. KMD 20441 PTARMIGAN BLVD.
/ ASDMr.. DAM EAGLE RIVER, AK 99577-8736
�Fessto`W, -ow 11 1 e o6
O+c. mc.ORO.NW1258 �--
ACRD EtC ftm_wvw. '108 M0'` 06-120 (907)808-3791/FAX (907)808-3793
WASTEWATER DISPOSAL SYSTEM MOUND DETAILS
T15N, R1W, SEC 9, SM, LOT 107
4' M[
K
4' MONITORING TUBE
PLAN VIEW_
LEACHFIELD DETAILS
4' MONITORING TUBE
PE MAX
FINAL GRADE 3.1 SLD
TO 2' DEEP
REMOVE ALL ORGi
8 LOAM
AV <� OF AL9S i
! 9 � A- * �l
6 N GI H «.t— 5 ;
CE -711
2'
WIDE
COVER
FINAL GRADE
SEWER ROCK
1'+ MIN M.O.A.
APPROVED
SAND FILTER
NOTE, BOTTOM OF SEWER DRAINROCK MUST BE 4+ FEET
ABOVE GROUNDWATER AND 6+ FEET ABOVE BEDROCK.
PREPARED FOR:
BRUCE MILLER
13140 MIDORI DR.
ANCHORAGE, AK 99516
(907)345-2096
FIELD BOOKS cawrzo-
eaMomr. SCHMLERAND oRAm: km
suR«c ocam KMO
ASOMP. DATE` 11/18 C
o� E. cm NW1258
AC" "IE` 'oB R" 06-120
SCALE, NTS
PAGE 3 OF 3
LAV B ENGINEERING, INC.
20441 PTARMIGAN BLVD.
EAGLE RIVER, AK 99577-8736
f--. . ..
(907)088-3791/FAX (907)868-3793
KNDD ENGINEERING, INC.
20441 PTARMIGAN BLVD.
EAGLE RIVER, AK 99577-8736
SOILS PERCOLATION TEST
Performed for: Bruce Miller Date
Project: T15N R1 W SEC 9 LOT 107 TEST IIOLE x 06-1
1-
2-
3-
4-
5-
6-
7-
8-
9-
10-
11-
12-
13-
14-
15-
16-
17-
18-
19 -
Depth
(Feet)
SEE ATTACHED SITE PLAN
Org/OL I FOR HOLE LOCATION
SM
seeps
GP—wet w/ cobbles to 1'
B.O.H.
HOLE PRESOAKED
20- PRIOR TO TEST
Was Ground water encountered? YES What depth? 6'
Depth to water after monitoring? 5' Date? 11/16/06
Reading
Date
Gross
Time
Net
Time
Dep to
Water
Net
Drop
1
11/10/06
1:00
6"
-
2
1:30
30 min
41/16"
115/16"
3
1:31
-
6"
-
4
2:01
30 min
43/16"
113/16"
5
2:02
-
6"
6
2:32
30 min
43/16"
113/16"
•
Water
Added
Percolation Rate 17 (min/ in) Perc Hole Diameter 6"
Test Run Between 2 feet and 3 feet
1, Kenneth 111. Duffus, certify that this test was performed in accordance with all State and Municipal guidelines in
effect on this date.
FIND ENGINEERING, INC.
20441 PTARMIGAN BLVD.
EAGLE RIVER, AK 99577-8736
696-6111 / FAX (907) 696-8111
ON-SITE WASTEWATER DISPOSAL SYSTEM
CONSTRUCTION PRACTICES AND MATERIAL SPECIFICATIONS
LEGAL DESCRIPTION: T15N R1W SEC 9, LOT 107
GENERAL:
I. The scope of this project includes the installation of aseptic tank and/or drainfield to serve a
single family residence on the referenced property as delineated on the attached Municipality of
Anchorage (MOA) permit and site plan.
1. Construction shall be in accordance with the approved site plan and design drawings; MOA
permit with any special provisions or conditions, and all applicable State and Municipal
Wastewater Disposal Regulations.
1. KND Engineering Inc (KND) assumes no responsibility of the accuraty of the as -built survey
provided by the owner or owner's representative.
1. The owner or contractor is responsible to notify the engineer of any discrepancies noted on the
design plans or drawings prior to commenting
or These discrepancies could be, but not
limited to, possible encroachments, surface water, varying soils, unplatted easements, types or
use of dwellings on or adjacent to property, nearby public wells, etc.
1. The contractor shall be responsible for locating any necessary underground utilities, easements,
property lines and surface water. The owner and/or contractor shall ensure, if deemed
appropriate, that a registered land surveyor prior to construction flags all setbacks.
1. The contractor shall be responsible for verifying all pertinent
component layout. separation distances and
1. Unless specifically agreed otherwise, the property owner shall be responsible for final grading
areas subsequently depressed from soil settling. On all leachfield mound systems, the property
owner shall be responsible for ensuring a satisfactory vegetation growth over the mounded
area.
1. The MOA Development Services Department On -Site Water 6r Wastewater Program must
certify contractors installing wastewater disposal systems. Owners installing their own systems
must also receive prior approval from said MOA Department.
SEPTIC TANK / HOLDING TANK / LIFT STATION INSTALLATION:
1. A septic tank is to be constructed by a certified septic tank manufacturer. Construction shall
include two 4" cleanouts for pumping access.
1. The septic tank shall be sufficiently bedded with proper material and compacting to prevent
damaging, settling or shifting of the tank
1. All standpipes on the septic tank shall extend a minimum of 12 inches above the final grade.
1. Septic tanks installed with less than 4 foot of cover shall be insulated. The contractor will
ensure that the fill over the tank does not exceed the burial depth rating.
1. A foundation cleanout shall be installed one to four feet from the building foundation. In the
line between the tank and the leachfield there shall be two adjacent cleanouts (unless an effluent
pumping system exists within the septic tank). These cleanouts shall be located on undisturbed
soil not more than 10 feet from the tank. The second cleanout, in line, shall be to clean toward
the septic tank.
1. Final grading over the septic tank shall be such that a positive slope exists away from the septic
tank.
Page 1 of 3
Reference: T15N R1W SEC 9 LOT 107
Date: 11/22/06
Page: 2 of 3
7. All H.D.P.E. tanks shall have a vertical length of 4 -inch perforated drainpipe besides the tank
extending to the bottom of the tank to above grade to monitor ground water.
S. All tanks shall be anchored when there is not enough adequate soil cover to resist buoyancy
forces in high -groundwater areas.
9. All holding tanks and lift stations shall have an audible and visual alarm inside the residence.
10. All lift stations shall be wired in compliance with the Uniform Electrical Code and all MOA
guidelines.
11. The contractor shall remove the old tank, or abandon it in compliance with the Uniform
Plumbing Code. The contractor is solely responsible for the abandonment procedure.
ABSORPTION TRENCII/DRAINFIELD INSTALLATION:
1. Excavate the proposed trench to the dimensions shown on the design. The bottom of the
excavation shall be within 2 inches of level. If the sidewalls of the excavaction become smeared,
they must be raked or scratched (roughed -up) before gravel (sewer rock) placement.
1. Once the sewer rock is installed, the distribution'
installed level with the perforations
facing downward. Gravel is then to be placed over the distribution
tribution pipe to provide a minimum
of 2 inches of cover over the pipe.
1. A silt barrier must be installed between the final gravel layer and the native soil backfill. Ensure
the silt barrier covers the entire gravel surface before placing ball.
1. Monitoring tubes shall be four- (4) inch diameter, installed approximately in the locations
shown on the design, and extend a minimum of 12 inches above final grade. The portion of the
monitoring tube extending through the gravel shall be perforated from the bottom of the trench
to the invert of the distribution pipe. This is equivalent to the effective depth of the gravel as
noted on the design.
1. Backfill over the final gravel layer must not be less than twenty-four inches. Insulation must be
installed when the backfill depth is less than thirty-six (36) inches. The finish grade over the
trench must be mounded to prevent the formation of a depression after settling.
1. All advanced technology waste water disposal systems (Advantex, Biocycle, Intermittent
Dosing Sand Filter, etc...) shall be constructed, installed, maintained and monitored per
manufacturer's specifications and MOA requirements.
MINIMUM MATERIAL SPECIFICATIONS:
1. A MOA approved septic tank manufacturer must construct any septic tank proposed for
installation.
1. The following pipe materials are MOA approved for use in septic system installations:
Type of PipesPerforate olid
Cast Iron Yes Yes
ASTM D3034 (PVC) Yes Yes
ASTM F810 (HDPE) Yes No
ASTM D2662 (ABS) Yes Yes
1. Insulation shall be at least Y' thick extruded direct burial polystyrene (Dow Chemical Company
Styrofoam HI or equal).
1. Septic tank inlets and outlets shall be fitted with watertight couplings (Caulder, Fernco, or
equal).
1. A permeable nontoxic silt barrier (Typar 3401, Miraft 140N, or equal) must be installed between
the final leachfield gravel layer and the native soil backfill.
1. All leachfield gravel (sewer rock) shall be 0S"-2.5" screened gravel with less than 37, passing
the #200 sieve. If deemed necessary, a sieve analysis should be performed.
1. When sand is being used as a filter material, its gradation specification must conform to current
MOA or DEC requirements.
Reference: T15N R1W SEC 9 LOT 107
Date: 11/22/06
Page: 3 of 3
INSPECTIONS:
Typically there will be three (3) inspections required during the installation of the wastewater
disposal system. These inspections will occur as follows:
1. The first inspection must be conducted after the excavation of ditches, pits, trenches, or beds
and before the installation of any gravel. A septic tank may be set in place, but may not be
backfilled before this inspection.
2. The second inspection must be conducted after thep
other backfill. lacement of the sewer rock, distribution
lines, standpipes, and cleanouts, but before the placement of the silt barrier, insulation or any
3. The final inspection is to occur upon final grading of the property.
Often there will be more than these 3 inspections required, especially with the installation of multiple
trenches, sand filters, pressurized distribution systems, etc. The inspecting engineer is to be contacted
at least 24 hours prior to the start of construction. If necessary, a pre -construction meeting will take
place on-site. The inspecting engineer will not coordinate, direct or control in any way the contractor's
activities.
The owner shall contract with the contractor to perform the work outlined in these specifications and
attached plans and in accordance with the attached MOA permit. All materials, components, and
construction practices shall comply with the MOA's and the State of Alaska's latest ordinances,
regulations, or policies regarding wells and septic systems. The failure of the inspecting engineer to
notice a material or construction non-compliance does not relieve the contractor of his/her
responsibility to correct such deficiency. There will be no contractual arrangement existing between
the contractor and KND Engineerin&, Inc. KND shall be the owner's representative and will inspect the
work as stated above to document the contractor's activities. Final acceptance of the contractor's work
rests with the owner and the MOA.
KND shall have no liability to the owner or to others for acts or omissions of the contractor or any other
persons performing work on this project or the failure of the contractor to carry out the work in
accordance with these construction documents. KND's inspecting engineer will not be responsible for
the construction means, methods, and techniques, sequence, procedures or the safety precautions
incident to this project.
BY PROCEEDING FORWARD WITH THE INSTALLATION OF THE WATER AND/OR
WASTEWATER SYSTEM (S), THE PROPERTY OWNER, CONTRACTOR, AND WELL DRILLER
ACKNOWLEDGES HAVING READ AND ACCEPTED THESE SPECIFICATIONS.
61 11�1r�/C� //l0.Lt jh �-, OW!'� e��'fO'%w Pi+%y
T ah J
eG/S e i�`'.�-i.`c_s.cC a�"�-4-T'`'S GnsasTi��%.vim eg��me�� tJ .�j
dl{^' worG�f'd G,..-. "S e».-.teri �,.G_� (��i /4 /7.iif
Cc.l44t,9' -,r 2a✓ e- aT irc/ /SIO II,jr i� Gl., c.le�✓'�c(< <
Municipality of Anchorage
't
Development
a•.
Development Services Department
Building Safety Division
On -Site Water and Wastewater Program S • 9 T •
4700 South Bragaw St.
P.O. Bou 196850 Anchorage, AK 99519.6850
www.ci.anchorage.ak.us
(907) 3437904
ON-SITE SEWER/WELL SUBMITTAL COMMENT SHEET
To: BRUCE MILLER
Legal description: T15N R1W SECS LOT 107
The attached paperwork has been reviewed and is being returned for the following reasons:
❑ Original signature or stamp missing on
❑ Calculation error in design.
❑ Additional soils information needed._ \\���ti t ACHO �
❑ Water monitoring results inadequate. _ �� O 4 -•,
El Discrepancy in information submitted. _A : •• •5���,a0 ;
❑ Water sample unacceptable.
❑ Proposed system too deep for soils information submitted.
❑
Well log required. _:• QQ���_�:
0 Omission in
El insufficient fill ver tank or field._ J'J���iJ •�1�EL0�'"' �P�\,\\
• •.••• \
�/JJJ1111)11))111
® Other. -NEED TO SHOW DOCUMENTATION OF EXISTING SEPTIC FIELD.
-NEED AN ACCURATE SITE PLAN TO SCALE SIGNED BY THE PROPERTY OWNER.
-NEED TO SHOW THE LOCATION OF THE PROPOSED WELL SITE AND THE LOCATION OF ALL WELLS AND
WASTEWATER SYSTEMS WITH IN 200 FEET OF THE SUBJECT AND THE ADJASCENT PROPERTIES,
-ALL APPLICABLE WELL RADII.
-PLEASE SEE ATTACHMENT "PERMIT REQUIREMENTS FOR A PRIVATE WATER WELL"
Name of reviewer: jQg
Date: October 30, 2006
Please supply the necessary information and re -submit your request.
LEAVE THIS FORM ATTACHED TO THE PAPERWORK