Municipality of Anchorage
On -Site Water and Wastewater Section • (907) 343-7904 Page 1 of 2
ON-SITE WASTEWATER INSPECTION REPORT
Permit Number: OSP191334 PID Number: 020-541-22
Dwelling: ❑ Single Family (SF) ❑ with ADU ❑ Duplex (D) ❑ Two Single Family Project: ❑ New ❑ Upgrade
Name
HARLAND &SANDRA HANNON
ABSORPTION FIELD
❑ Deep Trench ❑ Wide Trench ❑ Bed ❑ Mound
Site Address
16373 DIANE DR, ANCH AK
❑ other
Phone
Number of Bedrooms
Soil Rating
depth from original grade
4
5.0 GPD/SF
JTotal
+1.0 Ft.
LEGAL DESCRIPTION
Depth to pipe invert from original grade
+1.5 Ft.
Gravel depth beneath pipe
0.5 Ft.
Subdivision Block Lot
RABBIT CREEK VIEW & HEIGHTS BLK 3H LT 14A
Fill added above original grade
4.1+ Ft.
Gravel length
59 Ft.
Township Range Section
Gravel width
5.0 Ft.
Beds: Number of Lines
Distance between lines
Ft.
SEPARATION DISTANCES
To
Septic
Absorption
Lift Station
Holding
Sewer
Total absorption area
Number of trenches
Dist. between trenches
From
Tank
Field
Tank
Line
120+ Ft z
2
10 Ft.
Well'
5�+
!!
50 '+
TANK 0 Septic 0 S.T.E.P. 0 Holding Other
I
(
Manufacturer Capacity
Surface Water
54'+
Gal.
Material
Number of compartments
i
1
Lot Line
!
5'+
NA
Foundation
*51+
LIFT STATION
Manufacturer
Capacity
Remarks Advantex POD RE -LEVELED
Gal.
"NO STRUCT, IMPACTS, OUTSIDE 1:1 BEARING AREA
Alarm location
Electrical installed by
PIPE MATERIAL House to tank Tank to 3034
drainfield
Installer
MIKE N ANDERSON, P.E.
Drainfieid 3034 CO/MT3034
Inspector MIKE N ANDERSON, P.E.
BENCH MARK (Assumed elevation) 101.2 ft
Inspeection 1s, 8/23/20 8/23/20
Location and description
ction 2M
GARAGE SLAB
3'd 4'^
ON-SITE WATER AND WASTEWATER SECTION APPROVALP
Conditional Approval: Date
�,...:...... ;
N.
Septic System
Approved a 6"ZZedl Date
C,
Note: this approval does not include well permit requirements.
trcev vo/uzrnu)
Municipality of Anchorage
P.O. Box 196650 ® 4700 Elmore Road
Anchorage. Alaska 99519-6650 a (907) 343-7904 © Fax (907) 343-7997
http://www.muni.org/Onsite
Development Services Department
On -Site Water and Wastewater Section
�p�enr Sn
Depa tnieni
x x x x VARIANCE/WAIVER REVIEW x* x x
Waiver#: OSV201041 COSA#: Permit#:OSP191334
PID#: 020-541-22
Legal Description: Rabbit Creek View & Heights Block 3H Lot 14A
Engineer: Forge Engineering
Applicant: Harland & Sandra Hannon
Your request for a waiver of the maximum 3 to 1 mound side slope requirement has been
approved. The approved mound side slope is Imaximum 2 toI 1. See engineer's waiver request for
justifications. Cl �S�r �1cJv� ��c\o�cl -Tp �u nda,o� c�,p�Y 1c v2� hoz
This waiver approval applies to the proposed absorption field only. Any future upgrade to the
on-site wastewater disposal system will require all code requirements be met or another approval
from this department.
.............................................................................. 1
Waiver is Granted: X Waiver is not Granted:
Date: 7/�d d Approved by:j\.C,C�ii�A CSX
Name of Reviewer
............................................... ■ ............................. ■ t
**** VARIAN C EIWAIVE R REVIEW ****
Permit No. OSP191334
Page 2 of 2
Municipality of Anchorage
DEPARTMENT OF HEALTH AND HUMAN SERVICES
ENVIRONMENTAL SERVICES DIVISION
P.O. Box 196650 Anchorage, Alaska 99519-6650 Telephone: 343-4744
On—Site Wastewater Disposal System and/or Well Inspection Report
Legal Description: RABBIT CREEK VIEW & HEIGHTS BLK 3H LT 14A PID No.: 020-541-22
MARK
A
B
MT1
40
33
MT2
66
32
MT3
64
20
MT4
40
20
100' WELL RADIUS \
EXISTI7I/G 1500 GALLON FIBERGLAS TANK
EXISTING PUMP BASIIl
III O
I
I
1
ASBUILT 1
SCALE: 1"=50'
MT1 /4 MT2/3 0
4.2 •
RUSH GRADE TOPSOIL &SEED 100 OG Ar Aw
.� . .
i
,/-FILTER FABRIC &INSULATION FILL � 49 TFi : � •
101.5 101.5 •.......•
101 ORO
MICHAEL N. ANDERSON: AIF
GM/ML i
No. CE 9469 �.' � AF95
WATER ®96.5 JUNE 2020 .♦ �.�...11/5/20 ��
N.T.S.
SEPTIC
SSECTION �♦♦,11_••••.,,,� .�`
EXISTING WELL W/ 50' 'RADIUS
�
� I
I
� I
II
\
\
\
\\
MT —
/MT /
\\N
_TOPSOIL
EEDED
H, GARAGE SLAB DRIVEWAY
- --- —
\
/ OLD DRAIN PIPE DECOM
100' WELL RADIUS \
EXISTI7I/G 1500 GALLON FIBERGLAS TANK
EXISTING PUMP BASIIl
III O
I
I
1
ASBUILT 1
SCALE: 1"=50'
MT1 /4 MT2/3 0
4.2 •
RUSH GRADE TOPSOIL &SEED 100 OG Ar Aw
.� . .
i
,/-FILTER FABRIC &INSULATION FILL � 49 TFi : � •
101.5 101.5 •.......•
101 ORO
MICHAEL N. ANDERSON: AIF
GM/ML i
No. CE 9469 �.' � AF95
WATER ®96.5 JUNE 2020 .♦ �.�...11/5/20 ��
N.T.S.
SEPTIC
SSECTION �♦♦,11_••••.,,,� .�`
PLOT PLAN ___
AS BUILT _X_ SCALE 11 __ 40L _
GRID --SW-32-41- Project
No.
11500 Daryl Avenue, Anchorage, Alaska
99515-3049
Lang &
Associates, in c ,
(907) 522-6476 Phone
opp0
Professional Land Surveyors
(907) 522-4625 Fax
ken®longsurvey.como��
oo Op
()F q��o
jonothan®langsurvey.com
I hereb certif that
I have surveyed the following described
property:
O�'`P'•
L
y14Ao , BLOCK 3H, RABBIT CREEK VIEW & RABBIT CREEK HEIGHTS * 49TH
LOT.v*"
SUBDIVISION REPLAT PLAT No. 2004-91
Anchorage Recording District, Alaska, and that the improvements situated thereon are
within the property lines and do not encroach onto the property adjacent thereto, that �,• .. .
no improvements on the property lying adjacent thereto encroach on the surveyed O KENNETI{ LAN 00 -
premises and that there are no roadways, transmission lines or other visiblerl�' ►IjZpZp •.• o
easements on sold property except as Indicated hereon. o�4FRFo' SLS -5202 gJp4�
Dated this the � � _ Day of ___�vu�� _r.= Ya,2a _, at Anchorage, Alaska 44�nZOFPSS10NAL\'e0
It is the responsibility of the owner to determine the existence of any easements, AECC963
covenants, or restrictions which do not appear on the recorded subdivision plat.
8/4/20
Development Services DepartmentPhone: 907-343-7904
`'f ``-J
On -Site Water & Wastewater Section Fax: 907-343-7997
ON-SITE SEPTIC/WELL PERMIT APPLICATION
Parcel I.D. 020-541-22
Property owner(s) Harland and Sandra Hannon
Mailing address 16373 Diane Drive, Anchorage, AK 99516
Site address 16373 Diane Drive, Anchorage, AK 99567
Day phone
Legal description (Sub'd., Block & Lot) Rabbit Creek View & Heights; Block 3H, Lot 14A
Legal description (Township, Range & Section)
Lot Size Sq. Ft. Number of Bedrooms 4
APPLICATION IS FOR:
APPLICATION IS AN:
TYPE OF DWELLING:
(® all that apply)
Absorption Field
©
Initial ❑
Single Family (SF) 0
(w/wo ADU)
Septic Tank
ElUpgrade
ElDuplex
(D) EJHolding
Tank
ElRenewal
❑
Multiple Dwellings ❑
Privy
❑
(SF and/or D)
Private Well
❑
Water Storage
❑
TH✓I�S APPLICATION INCLUDES A WAIVER REQUEST FOR:
t% 1 M o h d S I L S�v pe Distance:
I certify that the above information is correct. I further certify that this is in accordance with
applicable Municipal Codes.
(Signature of property owner or authorized agent)
Permit/Rush Fees: n5
Date of Payment: 21149
Receipt Number: o?q6
Permit No. OL 12dq 13 3V
Waiver Fees: '$ 1(og. 7 5
Coy (_D -1q)
Date of Payment:f (e 1202-0
Receipt Number: o 1 (0 3 1 -I
Waiver No. 0 S N R01 (>4 1
GADevelopment Services\Building Safety\On Site Water and Wastewater\Forms\Client FormsTermit Application.doc
PO BOX 240773
ANCHORAGE, AK 99524
522-7773 677-7766 (FAX)
July 31, 2020
MOA Development Services Department
On-Site Water & Wastewater Program
4700 Elmore Road
Anchorage, AK 99507
Subject: Rabbit Creek View and Heights, Block 3H, Lot 14A – 16373 Diane Drive
Septic System Design
Dear On-Site Services Engineer:
The absorption trench on the subject lot has failed and must be replaced. We are therefore
requesting a permit be issued to allow the construction of a new septic system. The system will
be designed and constructed to accommodate four bedrooms even though the house currently has
only three. The existing Advantex treatment tank and pod was placed in 2014 and will remain in
service. The existing absorption trench will be decommissioned and abandoned in place.
The attached Site Plan and backup documentation identify the location and configuration of the
existing well and septic system and proposed absorption trench. No existing wells are less than
100’ from the proposed septic system and the well on the lot is more than 50’. The surface drainage
on the lot is to the northwest as shown by the surface contour lines on the plan. The drainage
pattern will not be changed as a result of this project.
The new absorption trench will be constructed to accommodate horizontal conveyance to transport
the effluent through the organic material surrounding the absorption trench and away from the
area. The distribution line in the trench will be placed at 1.5’ above the existing ground with the
bottom of the drain rock at 1.0’ above ground to provide 3.0’ of clearance from the in situ silt
below which has been found to be impermeable based on a test hole completed on the lot in June
of this year. Other test holes completed on the lot indicate permeable material may be encountered.
The water table was recently monitored at 3.5’ below the surface. A minimum of 3’ of MOA
approved coarse sand will be placed below the trench and above the in situ layer. A 1’ sidewall
composed of organic material and peat will be utilized for the horizontal conveyance.
A subdrain is in place on the lot near the proposed absorption trenches location. This drain will
be removed in its entirety to a minimum of 10’ from the new trenches. The excavated area will be
backfilled with in situ material. The backfill material will be compacted to the same extent as the
in situ material currently in place.
The trenches will be placed a minimum of 5’ from all lot lines and more than 10’ from the house
foundation and foundation drain. We are requesting the side slopes of the mound over the trench
be constructed with 2:1 slopes to minimize the area required for the mound. The slopes will be
stabilized with landscaping fabric, topsoil and grass seed after construction.
The ground surface on the lot in the area of the absorption bed slopes to the northwest at a shallow
grade. The new trenches will be constructed on a flat section of the lot, but slightly out of parallel
with the contours of the slope. MOA approved sand will be utilized as necessary to level the
trenches above the in situ GM/ML material. The new septic system will be constructed a minimum
of 50' from all wells and any surface water. If the system is constructed in accordance with our
design it will not conflict with adjacent wells and septic systems.
Sincerely,
Michael E. Anderson, P.E.
Attachments
®®®QEF 4< Ar
®°®e
•®�P' • •••.yS ®®®
AV
ff
Z
tr
......................................°:..... o
:......:::::..:....C:::-:... :..®
`'0 MICHAEL E. ANDERSON 1
0C :'®
_
4 ��? NO. CE -4381 ,
®®0/20.•••' Fay®
®� ®®OAe®ES
®®a®®®®®®s
FCO
1"=50'
3-BDRM HOME
NOTE:
NO SLOPES >25% WITHIN 50' OR SURFACE WATER WITHIN 50' OF THE
PROPOSED SEPTIC SYSTEM.
ALL WELLS ON SURROUNDING LOTS WITH IMPACTS TO THIS
PROPERTY ARE SHOWN. NO CONFLICTS WITH WELLS OR SEPTIC
SYSTEMS.
CO - CLEANOUT
2CO - DOUBLE CLEANOUT
FCO - FOUNDATION CLEANOUT
FS - FLOW SPLITTER VALVE
MH - MANHOLE
MT - MONITORING TUBE
SV - SEPTIC VENT
TH - TEST HOLE
LEGEND
RABBIT CREEK VIEW & HEIGHTS, BLOCK 3H, LOT 14A
7/31/20 FEET
0 50 100
EXISTING WELL
EXISTING WELL
50' RADIUS
EXISTING SUBDRAIN. TO BE
REMOVED & BACKFILLED WITH SILT
TO CREATE A PLUG TO 10' FROM THE
EDGE OF THE NEW TRENCHES.
EXISTING ADVANTEX
TREATMENT SYSTEM
w/PUMP VAULT
EXISTING ABSORPTION TRENCH
TO BE DECOMMISSIONED
2-25' LONG x 5' WIDE x
.5' EFFECTIVE DEPTH
ABSORPTION TRENCH
MT
MT
TH1
1195
1190
1185
TOE OF MOUND. GRADE TO
DRAIN AROUND HOUSE
FOUNDATION.
RABBIT CREEK VIEW & HEIGHTS, BLOCK 3H, LOT 14A
DESIGN FACTORS:SYSTEM REQUIREMENTS:
600 GPD PEAK FLOW
PERK RATE: 5.5 MIN/IN
APPLICATION RATE: 5 GPD/SF
5' WIDE SHALLOW TRENCH SYSTEM
EXISTING FOUR BEDROOM ADVANTEX
TREATMENT SYSTEM w/PUMP VAULT
TYPICAL TRENCH SECTION
(NO SCALE)
1" PERFORATED
PVC (HOLES DOWN)
DRAINFIELD ROCK
5'
6"
2'
NOTES:
1.GRADE AREA OVER TRENCH TO DRAIN AWAY
2.PROVIDE 3' OF COVER OVER TRENCHES AND 4' OVER SEPTIC TANK, OR 2'
WITH 2" OF INSULATION
3.CHECK GROUNDWATER AT TIME OF CONSTRUCTION. IF LEVEL IS HIGHER
THAN PREVIOUSLY OBSERVED, CALL ENGINEER IMMEDIATELY
BOTTOM OF TRENCH: 1' ABOVE GRADE
FLOW LINE ELEVATION: 1.5' ABOVE GRADE
TOP OF TRENCH: 4.0' ABOVE GRADE
600 GPD / 5 GPD/SF /1 LF ORGANIC DEPTH = 120 LF PERIMETER REQUIRED (120 LF SPECIFIED)
7/31/20
6"
MOA APPROVED SAND
2" INSULATION
HORIZONTAL FLOW DESIGN - 1' ORGANIC/PEAT
NOTE:
15 - 3
16" Diameter Holes per Trench @ 1.7' Spacing.
2
1
2
1
6" TOPSOIL &
REVEGETATE MOUND
2'
1'
EXISTING GROUND
Municipality of Anchorage .� fl. ,. ® £PaL
Development Services Department AL
Development
On -Site Water and Wastewater Section 00* `• �° ��
v •°
� yRr 4700 Elmore St. � � , C,TH
P.O. Box 196650 Anchorage, AK 99519-6650 �• • • • • ° • • ° • • • • • • • • ....
G
www.muni.org/onsite
(907) 343-7904 /I� ° ° • ° • "' " • •
9 �•° MICHAEL N. ANDERSON , ak-'0
Soils Lo9 - Percolation Test ��,���F,; •U/ry°•���`
11
Performed For: W- 0 ✓40M r I �Dhh o4... J Date Performed:
Legal Description: Pat 6(n , f r'* -C -e kl /4 TI Sin T S Township, Range, Section:
�- Vl evO Slope
(3�k.3�,
1-I (9 Jo)
4-I
6-
7-
8 -
Date
Gross Time
Net Time
Depth to Water
WAS GROUND WATER
9-
ENCOUNTERED?
S
10-
IF YES, AT WHAT DEPTH? S ' L
(v `
0
Depth to Water After P
11-
Monitoring? 3' Z E
12-
Date: (p r? 20
13-
14-
15-
16-
17-
18-
19-
20 -
COMMENTS
Site Plan
Ov-y—,—S.,Nkr 2-L4 k✓ S.
Reading
Date
Gross Time
Net Time
Depth to Water
Net Drop
(v `
5 //z
13 '/21
5-y 2,
PERCOLATION RATE Si � (minutes/inch) PERC HOLE DIAMETER & if
TEST RUN BETWEEN kj L FT AND ( FT
PERFORMED BY: Nflur, f I CERTIFY THAT THIS TEST WAS
PERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE. DATE: V I q
10' T&E EASEMENT
WELL
LOT 13A
R-100'
PROTECTIVE RADIUS N
22
Ilk
1 STORY
RESIDENCE <'x
TREATMENT 0
POD
MANHOLES
0,
The Of the StrU0",Ur0(8)aS
shown on this record drawing
ka,5-built) con Plies with Tifle 21 AMC.
By:
Oate-7-1
PLOT PLAN AS BUILT X SCALE 1" = 40' GRID SW 3241 _ Project No. 14-036Z65
11500 Daryl Avenue, Anchorage, Alaska 99515-3049
Lang & Associates, inc. (907) 522-6476 Phone
(907) 522-4625 Fax
Professional Land Surveyors ken 0longsuryey.com\OF 4 � . ......... .
jonathan0langsurvey.corn
1 hereby certify that I have surveyed the following described property:
LOT 14A, BLOCK 3H, RABBIT CREEK HEIGHTS (PLAT 2004-91) 49TH
Anchorage Recording District, Alaska, and that the Improvements situated thereon are ....... .......
within the property lines and do not encroach onto the property adjacent thereto, that
no Improvements on the property lying adjacent thereto encroach on the surveyed
KEN LA
premises and that there are no roadways, transmission lines or other visible
easements on said property except as Indicated hereon.
N
0, , *-
"-.LS-5202.-
Day Of at Anchorage Alaska
Dated this the I
It is the responsibility of the owner to determine the existence of any easements, 0)�ZSSIONA- 'y
covenants, or restrictions which do not appear on the recorded subdivision plot. AECC963
ury
Municipality of Anchorage
Community Development Department DEC F11e ply 01 3
On -Site Water and Wastewater Program
4700 Elmore St. • P.O. Box 196650 Anchorage, AK 99519-6650 • hftp://www.muni.org/onsite • (907) 343-7904
ON-SITE WASTEWATER INSPECTION REPORT
Permit Number: OSP141188 PID Number 020-541-22 ❑� New ❑ Upgrade
Narm
Harland & Sandra Hannon
ABSORPTION FIELD
❑ Deep Trench ❑� Shallow Trench ❑ Bed ❑ Mound
Address
16373 Diane Drive
El Other
Phone
Number of Bedrooms
Soil Rating
Total depth from original grade
-7 Q. -7 (�
32g' V / �I
4
2GPD/SF
+1 F1.
LEGAL DESCRIPTION
Depth to pipe invert from original grade
+1.5 Ft.
Gravel depth beneath pipe
0.5Fl.
Subdivision Block Lot
Rabbit Creek View and Heights 3H 14A
Fill added above original grade
4 Ft.
Gravel length
60 Fl.
Township Range Section
Gravel width
5.0Ft.
Beds: Number of Lines
N/A
Distance between lines
N/A Ft
SEPARATION DISTANCES
To
Septic
Absorption
Holding
Sewer
Total absorption area
Number of trenches
Dist. between trenches
From
Tank
Field
Lift Station
Tank
Line
300 '
Ft
1
N/AFt.
Well
124.3
127.63
133.5
N/A
25+
TANK ❑ Septic J❑ S.T.E.P. ❑ Holding .❑ Other
Manufacturer
Anchorage Tank/ Orenco
Capacity
1500G,1
Surface Water
100+
100+
100+
N/A
Material
Steel
Number of compartments
2
Lot Line
30.9
12.0
34.7
N/A
NA
Foundation
21.3
14.4
31.9
N/A
LIFT STATION
Manufacturer
Orenco
Capacity
250Gal
Curtain Drain
50+
50+
50+
N/A
Pump on level at
Pump off level at
High water alarm at
Remarks
43 in.
40m.1
45,n.
Pump make and model
Electrical Inspections performed by
P2005
MoA Building Safety
PIPE MATERIAL Housetotank 3034 Tank to 3034
drainfield
Installer
A+ Home Services
Drainfield 3034 CO/MT 3034
Inspector Pannone Engineering Services
BENCH MARK (Assumed elevation) 100ft
Inspection1° 12/2/2014
dales: 2m 12/2/2014
Location and description
P 12/2/2014 4
Nearest Door Jam
COMMUNITY DEVELOPMENT DEPARTMENT APPROVAL
Engineer's Stamp
OF AC
Conditional Approval: Date
� � • • • • • q��Js �`
irg�P �911A
• • ��even .� fsanrior�ej
r.�"-
CE 81 g�/
Approve (,wi �k Date
Inspection Report_t-1-12.doc
FA B \
T1
T1 29.7 24.6 \
72.5 70.9
M '
� I
M � ,
12
-- - _
0
LOT VACANT \ 'F'
WELLS OR SEPTICS F \ s --- o
o. F,pv2
\ �O
113 99y° �,� � ��y°y
y �0
LOT VACANT NEWT WELL
NO WELLS OR SEPTICS.
124.3
NEW 15008 S.T. E.P. TANK ,//LOT 1
W/ AX20 POD & AUX. PUMP VAULT
_ -. - 4BR
\
- - `Y A HOUSE
RESERVE DRAIN FIELD (P)/. y�Py _�
/ y
60lFxOS'EDxS'W\, +1.0'70 o��J� - T1 -FCO W
V LSI B
LS2 / \
g •M1 �
M2
y� NEW PRIMARY DRAIN FIELD F 15
° 60LFx O.5'EDx5'W, +1.0'TD I
M�MPLF�M _
'
/WELL (E)
16
NIS
I
SEPTIC AREA (E) W
3
NOTES: ���� \\ Date
PANNONE ENG SVC, LLC —�oF q�q�1�' 12/15/2016
RECORD DRAWING P.O. BOX 100217 ANCHORAGE, AK 99510 S S
PHONE (907) 272-8218 FAX (907) 272-8211 ig�P �yff Scale
j*:497►+ *�� 1"=so'
RABBIT CREEK VIEW & HEIGHTS, BLOCK 3H, LOT 4A .. • 0IiD-54 -22
HARLAND & SANDRA HANNON Steven PonnoSe j PERMIT N0.
f f�� CE 8149 ��
16373 DIANE DRIVE f c OSP 141188
PLAN ANCHORAGE, AK 99516 �Il``\ 5�==_ Sheett
SPECIAL PROVISIONS TO SPECIFICATIONS
1. ALL CONSTRUCTION WAS INSTALLED AS SPECIFIED IN THE MOST CURRENT EDITION OF THE MUNICIPALITY OF ANCHORAGE
STANDARD SPECIFICATIONS (MASS) FOR COMPONENT PARTS AND MATERIALS USED IN CONSTRUCTION OF ON-SITE
WASTEWATER DISPOSAL SYSTEMS AND ATTACHED SPECIAL PROVISIONS.
2. SCOPE OF WORK: INSTALLED NEW 1500g S.T.E.P. TANK WITH AX20 POD, SOIL ABSORPTION SYSTEM, AND WELL.
3. GROUNDWATER WAS MONITORED AT 3.1 FEET BELOW EXISTING GRADE AS EVIDENCED BY THE SOIL TEST HOLE. AN
APPARENT WATER TABLE WAS NOT OBSERVED IN ANY OF THE EXCAVATIONS LESS THAN 3.0 FEET BELOW EXISTING GRADE
NOTIFY THE ENGINEER IMMEDIATELY.
INSULATION a
ER FABRIC r
OIN ROCK 6' ABOVE PIPE INV FO
25• a PERF PIPE p
/,y' HOLES DRILLED IS O.C. 1
TOPSOIL A''
`/EGETATEL
��
COPPER
DIP
J
6.¢ _
¢
TH-1
FOUNDATION CLEAN OUT
NEIN 15009
O >
>
0 i
4 a
M#
QO
O
S.T. E.P. TANK
HOUSE ON
ju
w
F
'^ n
BUILDING PAD
0-
u
= 7
FFA 1000
ORIGINAL GRADE
FG
FINISH GRADE
INSULATION a
ER FABRIC r
OIN ROCK 6' ABOVE PIPE INV FO
25• a PERF PIPE p
/,y' HOLES DRILLED IS O.C. 1
TOPSOIL A''
`/EGETATEL
��
COPPER
DIP
DUCTILE IRON PIPE
6.¢ _
¢
TH-1
FOUNDATION CLEAN OUT
NEIN 15009
TANK CLEAN OUT N0.
9a.4- --'
-944 -1
M#
MONITOR TUBE NO.
92-e
S.T. E.P. TANK
DCO
DOUBLE CLEAN OUT
DV
92.3
91.9
FS
WlAX20 POD
MAINTAUILL -''dumelnm _T : LLT _v
-4'0
OG
ORIGINAL GRADE
FG
FINISH GRADE
NATIVE UNSATURATED SOIL BENEATH
-3.1' (5/15/:
SAND.
GM
-3.5' (10/1
PROFILE
-70
ML
-10.0
-85.¢
DESIGN PARAMETERS
PRIMARY/ RESERVE SEPTIC SYSTEM
NO. BEDROOM: 4 (600 gpd)
TANK SIZE: 15009 S.T.E.P.
W/ AX20 POD & AUX. PUMP VAULT
PERC RATE = 40 MPI
SOIL RATING: 2 GPD/SF
AREA ROD: 300 SF
SYS. TYPE: WIDE TRENCH 0.5' E.D.
MIN LENGTH: 60 LF
USED:
60 LF X 5' WIDE, 0.5' E.D..
+1.0' TO
TOTAL AREA: 300.0 SF
LEGEND
W WATERLINE/
WELL RADIUS
— SS — NEW SEPTIC
ABBREVIATIONS
CU
COPPER
DIP
DUCTILE IRON PIPE
TH
TEST HOLE
FC
FOUNDATION CLEAN OUT
T#
TANK CLEAN OUT N0.
C#
CLEAN OUT NO.
M#
MONITOR TUBE NO.
R. 1.
RIGID INSULATION
DCO
DOUBLE CLEAN OUT
DV
DIVERTER VALVE
FS
FLOW SPLITTER
BFG
BELOW FINISH GRADE
OG
ORIGINAL GRADE
FG
FINISH GRADE
NOTES: ������\\� Dale
PANNONE ENG SVC, LLC OF A( �� „/z,/,B
RECORD DRAWING P.O. BOX 100217 ANCHORAGE, AK 99510 ?'C� ..
PHONE (907) 272-8218 FAX (907) 272-8211%aj�p syl+� Scale
/* NTs
�....... .... P.I.D. NO
RABBIT CREEK VIEW & HEIGHTS, BLOCK 3H, LOT 1 -541-22
HARLAND & SANDRA HANNON �'te've'r ann&;+ ' j PERMIT No
c. OSP,au88
CE 8149 .•�?��
DIANE DRIVE fM ��
DESIGN DETAILS ANCHORAGE, AK 99516 1111 .......P��s Sheet
`�\PROF-'
� 3 OF 3
04/15/2014 00:27 907-345-0202 ALPINE DRILLING PAGE 02/02
Alpine Drilling & Enterprises
Well Log
Permit Number: 4SW 141188 Date of Issue: Parcel Identification Number: 02054122000
Date Started: A;,1-14 Date Completed. 8-1_14 Is well located at approved permit location? x Yes ❑ No
Legal Description: Rabbit Creek View & Heights Fll13N A•f 1*4
Property Owner Name & .Address: Hannon Hadand N & Sandra L
1946 W Athena Drive
North Pole, Alaska 99705
Borehole Data: Deptb (ft)
Soil Type. Thickness & Water Strata From To
Method of Drilling x air rotary ❑ table tool
Casing type: "Eel
Stick-up 0
3
Wall Thickness: �210 inches
Rock fill 3
Organics & silt S
5
?
Diameter: 6 inches Depth: E feet
Liner Type:
Diameter: _ inches Depth: _ feet
silt 7
11
Casing stickep above round: 2 fee:
Static water level (from ground level): Meet
gravelly silt 11 54
silty water sand & gravel 54
gravelly silt 56
56
.57
Pamping level: -15 feet after
2 hours ptunping Z gpm
Recovery hate: 7 gpm
Method of Testing: &M
Well Intake Opening Type:
x Open End ❑ Open Hole
❑ Screened Start _ feet Stopped feet
❑ Perforations Start_ feet Stoppedfeet
Grout Type: bearonite gwules Volume:
F4ATIR �q� STING
Depth: 0 feet Stopygd9feet
Pump: Intake Depth ^ feet
CoV100mi-
U91V
Pump size —,_ hp Brand Name_tSenir,
Well Disinfected Upon Completion! x Yes [,] No
lortne tablets
Method of Disinfection: ch_
Comments:
Well Driller: Alpine Drilling & .Enterprises
PO Box 110496
Anchorage AK 99511
I
Apr 0717 04:26p Anchorage Well & Pump Ser 9072430742 p.2
Development Services Department
Building Satety Division
On -Site Water & Wastewater Program
4700 Efmore Road
P.O. Box 196650
Mark Becrich Anchorage, A K 99507
Mayor www.muni.org/onsite
(907) 343-7904
rUFIIIlr firt5tallation L_Uq
Well Drilling Permit dumber: SW Date of Issue: /3o/1 `I
Parcel: Identification Number: �O- .5�22
Legal Description Property Owner Name & Address:
3-L V ie� I-felf,` Gfs /AR�4�a 5q�tdKA Nt�nt�o�f
/3 H L-1 y f1
Pump Installation Date: 0-24>-141 �j '7 95I
Pump Intake Depth Beloit/ Top of Well Casing: ��j feet
Pump Manufacturer's Name: ' jEb JACKET
Pump Model: 8812
Pump Size '/2 hp
Pitless Adapter Burial Depth: 8 feet
Pitless Adapter Nfanufacturer's Name: —3A K6-72
Pitless Adapter Installer: A WAS
Well Disinfected upon Completion? X Yes ❑ No
Method of Disinfection:
Comments:
Pump Installer Name:WIN'
ANCHORAGE WELL & PUMP SERV.
330 EAST 76 '� AVENUE
ANCHORAGE, AK 99518
PHONE: 907-243-0740
AWPS.COM
Attention: The pump installer shall provide a pump installation lag to the DSD udthin 30 days of pump installation.
ADVANCED WASTEWATER TREATMENT SYSTEM
MAINTENANCE AND REPAIR AGREEMENT
BETWEEN MUNICIPALITY OF ANCHORAGE
AND Y �'a J
THIS MAINTENANCE AND REPAIR AGREEMENT made and entered into as of this
Day of of 20/1 by and between
herein the "O ER," and the Municipality of Anchorage, herein the
"MUNICIPALITY." In consideration of the mutual covenants contained herein, the
parties to this Maintenance and Repair Agreement agree as follows:
1. Advanced Wastewater Treatment Systems. Municipality grants permission to
Owner to utilize and operate an Advanced Wastewater Treatment System
(AW WTS), described as
2. vei masons.
located at (legal description).
Alteration. Any change to the design or function of an A W WTS that
includes the installation or removal of any parts, components or pieces not
included in the original construction permit and design.
Certificate of On -Site Systems Approval (COSA). An approval by the
Municipality of existing water and wastewater disposal systems given at
the time of property sale and title transfer in accordance with Anchorage
Municipal Code (hereinafter, "AMC") 15.65. These approvals certify that
the systems are adequate for the homes that they support and meet the
codes that were in place at the time of system construction.
Damage. Any man-made or natural change in a system that would inhibit
the system from performing as designed.
Maintenance and Repair. The scheduled and as needed replacement of
existing parts, components and pieces of an AW WTS that were included
in the original design which would allow the AW WTS to continue to
perform as designed.
Permit. An On -Site Wastewater Disposal Permit as required by AMC
15.65 to construct and operate an AW WTS.
3. Term. The term of this Maintenance and Repair Agreement shall begin on the
date of approval by the Municipality to operate the installed system or issuance of a
COSA, and shall continue while the AW WTS is in use or is operational or until the
property is sold or title is transferred by the owner and a new COSA is issued to the
new owner or transferee of the property.
4. Alterations, Installation and Removal of Additional Euuipment. Prior to
performing any alterations to an AW WTS, the owner agrees to obtain an On-site
Wastewater Disposal Permit from the Municipality in accordance with AMC 15.65.
5. Maintenance and Repairs.
A. Throughout the term of this Maintenance and Repair Agreement, the Owner shall
maintain their AW WTS in a satisfactory condition capable of producing treated
septic effluent in accordance with the equipment's approval for operation in the
Municipality. The owner shall enter into a service agreement with an AW WTS
service and maintenance provider approved by the municipality and the
manufacturer of the AWWTS for the entire term of the AWWTS. In addition, it
shall be the responsibility of the Owner during the term of this Maintenance and
Repair Agreement, and any renewals thereof, at the owner's sole expense, to pay
for any and all: (1) repair(s), (2) maintenance, (3) adjustment(s), (4) replacement
costs, and (5) inspection costs.
B. Owner agrees to comply with all applicable ordinance, laws, regulations, rules
and orders for the AWWTS.
C. Upon request by the Municipality, the owner agrees to provide the Municipality a
written schedule of routine maintenance and repairs which have been performed
on the system. When a record of maintenance is documented and maintained by
the system vendor, the owner agrees to allow the Municipality access to this
information.
D. Owner acknowledges that the fine for failing to maintain and repair an AWWTS
may be assessed in accordance with AMC 14.60 for improper discharge.
E. Owner agrees that only maintenance and repair personnel approved by the
Municipality will inspect and make any necessary maintenance, repairs or
permitted alterations to the system.
F. Owner agrees to grant the Municipality reasonable access to test and inspect the
AWWTS upon 24 hours written notice.
G. Owner agrees that any sale or transfer of title of the property will not occur
without a new Certificate of On -Site Systems Approval.
H. Owner agrees that the AW WTS installation and maintenance requirements as
provided by the AWWTS vendor/installer and approved by the Municipality are
the governing guidelines for the construction, maintenance and repair of the
Owner's AW WTS.
6. Nonwaiver. The failure of either party at any time to enforce a provision of this
Maintenance and Repair Agreement shall in no way constitute a waiver of the
provisions, nor in any way affect the validity of the Maintenance and Repair
Agreement or any part hereof, or the right of such party thereafter to enforce each and
every provision hereof.
7. Amendment.
A. This Maintenance and Repair Agreement shall only be amended, modified or
changed by a writing, executed by authorized representatives of the parties, with
the same formality that this Maintenance and Repair Agreement was executed
with, and such writing shall be attached to this Maintenance and Repair
Agreement as an amendment.
B. For the purposes of any amendment modification or change to the terms and
conditions of this agreement, the only authorized representatives of the parties
KTIM
a. Owner:
b. Municipality: Director, Community Development or designated authority
C. Any attempt to amend, modify, or change this contract by either an unauthorized
representative or unauthorized means shall be void.
8. Jurisdiction: Choice of Law. Any civil action arising from this Maintenance
and Repair Agreement shall be brought in the Superior Court for the Third Judicial
District of the State of Alaska at Anchorage. The laws of the State of Alaska shall
govern the rights and obligations of the parties under this Maintenance and Repair
Agreement.
9. Severability. Any provisions of this Maintenance and Repair Agreement decreed
invalid by a court of competent jurisdiction shall not invalidate the remaining
provisions of the Maintenance and Repair Agreement.
STATE OF ALASKA )
ss.
THIRD JUDICIAL DISTRICT )
Date: oiD%�/
The foregoing instrument was acknowledged before me this day of ju-'t e-
20ji , by 1 v vioo
TAR "LC
PU
N•O=TSAR+Y�PUBL[C FOR ALASKA °O )0 S
C 0k tE^cut
STATE OFILC
ALASKA
'M fOt1Ml^"i.�tl Fxa,F SAquST1A, 9015
My Commission expires: 0 i S
MUNICIPALITY: ` _
By: �w 'v"l (signature)
Date: 3 —� r7-1
name) Title:
On -Site Water & Wastewater System Permit
Permit Number: OSP141188
Tax Code Number: 02054122000
MUNICIPALITY OF ANCHORAGE
Development Services Department
On -Site Water & Wastewater Program
4700 Elmore Road, PO Box 196650
Anchorage, AK 99519-6650
Telephone: (907) 343-7904
Work Type: WellSeptic Initial
Permit Effective Dates: June 30, 2014 to June 30, 2015
Design Engineer: PANNONE ENGINEERING SERVICE
Subdivision: RABBIT CREEK VIEW & HEIGHTS
Site Legal Address: RABBIT CREEK VIEW & HEIGHTS BILK 3H LT 14A G:3241
Owner/Address: HANNON HARLAND N & SANDRA L
1946 W ATHENA CIRCLE NORTH POLE AK 997050000
Site Mailing Address: Lot Size in Sq Ft: 19204
Total Bedrooms: 3
This permit is for the construction of:
Y Disposal Field Y Septic Tank N Holding Tank N Privy Y Private Well N Water Storage
All construction must be in accordance with:
1. The attached approved design.
2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater
Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80).
3. The wastewater code requires inspections during the installation. The engineer must notify the Development Services
Department at least 2 hours prior to each inspection. Provide notification by calling (907) 343-7904 (24 hours).
4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must either:
A. Open and Close on the same day.
B. Covered, sealed, and heated to prevent freezing.
Special ProvisionsVIM6ZHOlhal maintenance agrerement shall b6 suliffiitt prior to apj3i&t ik4,
f!.0�1 ifrtion I'e�s
Receivs
Issued
MUNICIPALITY OF ANCHORAGE
aaa
Community Development Department Phone: 907-343-7904
Development Services Division Fax: 907-343-7997
On -Site Water & Wastewater Program
ON-SITE SEWER/WELL PERMIT APPLICATION
Parcell.D. 020-541-22
Property owner(s) Harland & Sandra Hannon
Mailing address 1946 W. Athena Cir., North Pole, AK 99705
Day phone
Site address NSN Diane Dirve
Legal description (Sub'd., Block & Lot) Rabbit Creek View and Heights, Block 3H, Lot 14A
Legal description (Township, Range & Section)
Lot Size 19,204 Sa. Ft. Number of Bedrooms 3
APPLICATION IS FOR: APPLICATION IS AN: TYPE OF DWELLING:
(® all that apply)
Absorption Field
Septic Tank
Holding Tank
Privy
Private Well
❑X Initial ❑X Single Family (SF) ❑X
(w/wo ADU)
❑X Upgrade ❑ Duplex (D) F1❑ Renewal ❑
® n �- u IpleDwellings ElElC t B M I 1 TA F and/or D)
FX V L
Water Storage ❑
JUN 1 1 2014
THIS APPLICATION INCLUDES A VARIANCE / WAIVER REQUEST FOR:
Distance:
I certify that the above information is correct. I further certify that this is in accordance with
applicable Municipal Codes.
(Signature of property owner or
Permit/Rush Fees:
Date of Payment: l
Receipt Number: 61 (ztega
Permit No. osell 1199
Permit App_:- > :L..:c-
Waiver Fees:
Date of Payment:
Receipt Number:
Waiver No.
Pannone Engineering Services LLC
Steven R. Pannone, Principal
Registered Professional Engineer
E-mail: steve@panengak.com
June 12, 2014
Municipality of Anchorage
Development Services Department
On -Site Water & Wastewater Program
4700 Elmore Road
P. O. Box 196650
Anchorage, Alaska 99519
Subject: Rabbit Creek View and Heights, Block 3H, Lot 14A
Septic System Permit Request
Ladies and Gentlemen:
I am writing to request a permit to install a new septic system be issued for this property. The proposed
systems will serve a proposed three (3) bedroom house. Currently the lot is undeveloped. The proposed
system will utilize a 1500g S.T.E.P. tank with AX20 Pod and auxiliary pump vault. The surrounding
developed lots are served by private wells. There are no wells on surrounding lots within 100 feet of this
system and there are no septic systems installed on the surrounding lots within 100 feet of the proposed
well.
Soils. One test hole was performed on this lot by Pannone Engineering Services in 2005, and groundwater
was monitored for seven days. Ground water was observed at three point one feet (3.1') below the
surface in the test hole monitor tube in May of 2005. Bedrock was not encountered in the test hole. It is
my opinion, based on the results of the percolation tests and overall soils appearance; an application rate
of 2.0 gallons/day/square feet should be used for a CAT III wastewater system.
1. Soil Absorption System Design.
a. See Sheet 2 of the design package.
2. Surface Water: There is no surface water within 100 feet of the proposed septic tank and drain
field. The proposed drain field upgrade will maintain at least 100 feet from all surface water and drainage
ditches.
3. Topography: The existing topography slopes from the south to north at approximately 5% in the
area of the proposed drain field. There are no steep slopes within 50' of the proposed drain field. The
proposed drain field will maintain 50' separation all steep slopes.
4.
(flailing: P.O. Box 100217, Anchorage, AK 99510-0217
Physical: 332 East Manor, Anchorage, AK 99501
Telephone: (907) 272-8218 FAX: (907) 272-8211
Page 2 of 2
5. Drawing Markings: The Drawings are marked "For MoA Review Only". When written notification
that the review is complete and that there are no further comments is received from MoA On -Site
Department, the note will be removed and "Issued for Construction" drawings will be issued.
The proposed installation will not affect the future development of the surrounding or existing lots. There
are no surrounding wells within 100 feet of the proposed septic location.
If you have any questions or concerns, please contact me at 272-8218.
Sincerely,
Steven R. Pannone, P.E.
Owner/Civil Engineer
Mailing: P.O. Box 100217, Anchorage, AK 99510-0217
Physical: 332 East Manor Ave, Anchorage, AK 99501
Telephone: (907) 272-8218 FAX: (907) 272-8211
12o... .. .
LOT VACANT
WELLS OR SEPTICS
0,
41-
v03
92
13
-
LOT VACANT WELL (P)
NO WELLS OR SEPTICS
l 03.7
4234.1
BR OT 14 TO RABBIT CREEK
HOUSE
(P) N\
NN
CD 1500g S.T.E.P. TANK (P)
W/ AX20 POD & AUX. PUMP VAULT
T - H ' -1
PRIMARY DRAIN FIELD (P)
45LFxO.5'EDx5'W, + 1.0'TD
15
N\ 44 RESERVE DRAIN FIELD (P)
45LFx0.5'EDx5'W, +1.0'TD
Is
ZWELL (E)
16
SEPTIC AREA (E) w
N
NOTES: �A Dote
PAMONE ENG SVC, LLC 6/23/14
FOR CONSTRUCTION P.O. BOX 100217 ANCHORAGE, AK 99510 . ......... 4,9
PHONE (907) 272-8218 FAX (907) 272-8211 Scale
W:
........ . . P.I.D. NO
RABBIT CREEK VIEW & HEIGHTS, BLOCK 3H, LOT 14A- .. -029-541-22
HARLAND & SANDRA HANNON M'e'v*e'n' '�. an '8.n;' PERMIT NO.
1, -. CE 8149 ..-
%
DIANE DRIVE OSP141188
PLAN ANCHORAGE, AK 99516 ........ Sheet
1 OF 3
SPECIAL PROVISIONS TO SPECIFICATIONS
1. ALL CONSTRUCTION SHALL BE INSTALLED AS SPECIFIED IN THE MOST CURRENT EDITION OF THE MUNICIPALITY OF
ANCHORAGE STANDARD SPECIFICATIONS (MASS) FOR COMPONENT PARTS AND MATERIALS USED IN CONSTRUCTION OF
ON–SITE WASTEWATER DISPOSAL SYSTEMS AND ATTACHED SPECIAL PROVISIONS.
2. SCOPE OF WORK: INSTALL NEW 1500g S.T.E.P. TANK WITH AX20 POD, SOIL ABSORPTION SYSTEM, AND WELL.
3. GROUNDWATER WAS MONITORED AT 3.1 FEET BELOW EXISTING GRADE AS EVIDENCED BY THE SOIL TEST HOLE. IF AN
APPARENT WATER TABLE IS OBSERVED IN ANY OF THE EXCAVATIONS LESS THAN 3.0 FEET BELOW EXISTING GRADE
NOTIFY THE ENGINEER IMMEDIATELY.
1.25" 0 DRAIN PIPE
W/)¢" HOLES DRILLED 18" O.C.
FILTER FABRIC
RIGID INSULATION
DRAIN ROCK
3 (NP) TOPSOIL AND
1 VEGETATE (NP)
TH-1 1.D t.„
–1.0 OR 4I.1 - .. ,
ML _1
–4.0. 1' (5/75/2005) MAINTAIN A MINIMUM OF 2.0 FEET OF
NATIVE UNSATURATED SOIL BENEATH
GM –3.5' (10/15/205)
SAND.
–7.0
ML SECTION
–10.0
J
G m RIGID INSULAPON m
O� j p a r RLTER FABRIC r
p ¢ DRAIN ROCK G" ABOVE PIPE INV o
~ 01.25" 0 PERF PIPE o
O 9 x W/ 1y" HOLES DRILLED 18" O.C.
HOUSE (P) �� _ TOPSOIL AND
ON BUILDING PAD J a VEGETATE (11'P)
NEW 1500 g,a.
RIGID INSULATION S.T.E.P. TANK MAINTAIN A MINIMUM OF 2.0 FEET OF
W/ AX20 POD TRENCH SEE DESIGN NATIVE UNSATURATED SOIL BENEATH
SAND.
PROFILE
LEGEND ABBREVIATIONS
DESIGN PARAMETERS CU COPPER
PRIMARY/ RESERVE SEPTIC SYSTEM W WATER LINE/ DIP DUCTILE IRON PIPE
NO. BEDROOM: 3 (450 gpd) WELL RADIUS TH TEST HOLE
TANK SIZE: 15009 S.T.E.P. FC FOUNDATION CLEAN OUT
W/ AX20 POD & AUX. PUMP VAULT — SS NEW SEPTIC T# TANK CLEAN OUT NO.
PERC RATE = 40 MPI C# CLEAN OUT NO.
SOIL RATING: 2 GPD/SF M# MONITOR TUBE NO.
AREA ROD: 225 SF R.I. RIGID INSULATION
SYS. TYPE: WIDE TRENCH 0.5' E.D. DCO DOUBLE CLEAN OUT
MIN LENGTH: 45 LF DV DIVERTER VALVE
USE: FS FLOW SPLITTER
45 LF X 5' WIDE, 0.5' E.D., BEG BELOW FINISH GRADE
+1.0' TD OG ORIGINAL GRADE
TOTAL AREA: 225.0 SF FG FINISH GRADE
NOTES: PANNONE ENG SVC, LLC '''OF q(\i 5ate 6/23/14
FOR CONSTRUCTION P.O. BOX 100217 ANCHORAGE, AK 99510 i '��.... qS 1,
PHONE (907) 272-8218 FAX (907) 272-8211* 49 TH �/ Scale
..... - .. :.. NTS
P.I.D. NO
RABBIT CREEK VIEW & HEIGHTS, BLOCK 3H, LOT 14 ..... 020-541-22
HARLAND & SANDRA HANNON Steven R. Pannone' PERMIT NO.
CE 8149 OSP141188
DIANE DRIVE
DESIGN DETAILS ANCHORAGE, AK 99516IHtOFESSp� Sheet
`\\ 2 OF 3
4" JIM
4" PUMP -
SLIDE SEC-
OF6"f
OVER THIS CONNEC-
TO PROS
SHEER PROTECTI(I .—
EXTEND TO
BRIDGE EXCAVATION
ADVANTEX DESIGN
ADVANTEX ".1
TANK BEDDING DETAIL
r-8,
SECTION
NOTES:
FOR CONSTRUCTION
SITE SECTION
3.6' NATIVE MATERIAL
�2' MOA TYPE II GRAVEL (NFS)
ABED TANK W/
SEWER ROCK
2000 S.T.E.P. TANK
L -LIMITS OF EXCAVATION
I- 2' TYP..
PASSIVE
AIR
BUOYANCY CALCULATION
WEIGHT CALCULATIONS
Buoyant Force = Weight of Water Displaced
((Plx(5.3)-2/4)x12)x62.4 PCF = 16,728 # Up
COUNTER WEIGHT
Assume water ® surface - all soil saturated
Assume angle of repose = 0 Degree
Assume bedding does not add to force down
Assume tank has no weight
Weight of MoA Type II (135 PCF - 62.4 PCF)=72.6
pcf
(2'x5.3x12)x72.6 PCF = 9,234 # Down
Weight of Native Soil (120 PCF - 62-4 PCF)=57.6
pcf
(3.6'x5.3x12)x57.6 PCF = 13,188 # Down
Total Weight on Tank = 22,422 # OK!
PANNONE ENG SVC, LLC
P.O. BOX 100217 ANCHORAGE, AK 99510
PHONE (907) 272-8218 FAX (907) 272-8211
RABBIT CREEK VIEW & HEIGHTS, BLOCK 3H, LOT 14A
HARLAND & SANDRA HANNON
DIANE DRIVE
ANCHORAGE, AK 99516
IAI�,
c3/14
Sale
NTNG
*:49TH *�/�
•Steven•F�)•Penrione•/
020-541-22
19�•. CE 8149 j
1
PERMIT N0.
OSP141188
.: 1P}'70FESSlO
Sheet
eOF
3
Municipality of Anchorage
Development Services Department
• +� Building Safety Division
On -Site Water and Wastewater Program
4700 South Bragaw St.
P.O. Box 196650 Anchorage, AK 99519-6650
www.muni.org/onsite
(907)343-7904
ON-SITE SEWER/WELL SUBMITTAL COMMENT SHEET
To: Pannone Engineering
Legal description: Rabbit Creek Heights, Block 3H. Lot 14A
The attached paperwork has been reviewed and Is being returned for the following reasons:
❑ Original signature or stamp missing on
❑ Calculation error in design. _
❑ Additional soils information needed.
❑ Water monitoring results inadequate.
❑ Discrepancy in information submitted. _
❑ Topographic information missing or inadequate. _
❑ Incomplete; missing
❑ Incomplete; missing
❑ Additional adequacy test information needed.
❑ Water sample unacceptable. _
❑ Measured/proposed distances/dimensions missing. _
❑ Locations of all soils, percolation and water monitoring tests not shown.
❑ Proposed system too deep for soils information submitted.
❑
Well log required.
❑ Omission in narrative.
❑ Insufficient fill over tank or field._
® Other. 1.) Need additional test holes: 2.) Due to high groundwater, need to conduct
groundwater through May 15, 2006; 3.) Six (6) inches of top soil required on mound system
Name of reviewer: Julie Makela, P. E.
Date: 12/22/2005
Please supply the necessary information and re -submit your request.
LEAVE THIS FORM ATTACHED TO THE PAPERWORK
Municipality of Anchorage
• Development Services Department
Building Safety Division
On -Site Water and Wastewater Program
4700 South Bragaw St.
P.O. Box 196650 Anchorage, AK 99519-6650
www.cf.anchorage.ak.us
(907)343-7904
ON-SITE SEWER/WELL PERMIT APPLICATION
FOR A SINGLE FAMILY DWELLING
Parcel I.D. 020.541.22 Permit Number SW
Property
Mailing address (1
phone (305) 6513072
Mailing address (2) /JmN NAAjt; � Zip Code qa to
Legal description (Lot, Block & Sub'd.) _ Lot 14A. Block 3H Rabbit Creek Heights
Legal description (Section, Township & Range)
Lot Size 19,204 Acreq.
.
THIS APPLICATION IS FOR:
Site Location: Diane Drive
Number of Bedrooms
Sewer Only ❑ Well Only ❑
Sewer and Well ® Water Storage ❑
Sewer Upgrade ❑
THIS PROPERTY CONTAINS:
Hot Tub ❑ Jacuzzi ❑
Swimming Pool ❑ Water Softening Unit ❑
Therapy Pool ❑
certify that the above information is correct. I further certify that this application is being made for a
Single Family Dwelling and is in accordance with applicable Municipal Codes.
(Signature of property owner or authorized agent)
Permit Fees: 4&o '°a W Y5 -JD // '' Waiver Fees: _
Date of Payment: ISI Iy�, I d5 IZ�c/G�ate of Payment:
Receipt Number: 1 LI%W y,
(Rev. 12100) �C/?ke�eipt Number:
T—^
#4
102OU
AKMIO
Pannone Engineering Services, LLC P.O. Box 102954
Consulting Engineers Anchorage, Alaska, 99510
(907) 272-8218 (907) 272-8218 Fax
December 14, 2005
Municipality of Anchorage
Development Services Department
On -Site Water & Wastewater Program
4700 S. Bragaw Street
P. O. Box 196650
Anchorage, Alaska 99519
Subject: Lot 14A, Block 3H Rabbit Creek Hts S/D
Well and Septic System Permit Request
Ladies and Gentlemen:
I am writing to request a permit to construct new well and septic system be issued for
this property. The proposed systems will serve a proposed three-bedroom house.
Currently the lot is undeveloped. The well will be located in the northeast comer of the
lot, over 100 feet from the proposed septic system.
1. Soils. See the attached soils log. Ground water was monitored for through the
seasonal high ground water of spring and fall of 2005. Ground water was measured at a
depth of 3.1 feet below ground surface on May 15th of this year and 3.5 feet on October
15th. Bedrock was not encountered in the test hole. It is my opinion that the overall soils
appearance of the soils, an application rate of 0.3 gallons/day/square feet should be
used using a conventional system and 2.0 gpd/sf using a class III advanced treatment
system.
2. Trench Design.
a.
Percolation Rate:
b.
Application Rate:
c.
Number of Bedrooms:
d.
Design Flow:
e.
Min. Absorption Area:
L
Total depth:
g.
Effective Depth:
h.
Width:
i. Reduction Factor:
j. Minimum Length:
k. Design Length:
1. Effective Absorption Area:
m. Septic Tank Size:
Cont'd on page 2
C:\Work\Letters\l4A-3H Rabbit Creek Hts.doc
40 Min Per Inch
0.3 gpdpsf
3
450 gallons per day
1500 sf
1 feet
0.5 feet
25 feet
0.0
60 feet
60 feet
1500 sf
1000 gallon Septic.
Page 2
3. Surface Water: There is no surface water within 100 feet of the proposed system.
The proposed systems will maintain at least 100 feet from all surface water and drainage
ditches.
4. Topography: The average topography in the area of the proposed septic system is
approximately 2 percent in the area of the SAS (based on existing topographic survey
conducted in 1988).
S. Reserve System: The reserve system is based on the use of an Advantex AX20
system. The site plan shows the reserve system size and location, as well as the design
calculations and details.
6. House Location: This lot is sized to the minimum area required by the municipal
code. The location for the septic system is the only location that is acceptable on this lot.
The Owner agrees that they will not move the house from the area shown on the
Engineering Site Plan, or they will coordinate with the Engineer before moving the
house. Moving the house into the reserve septic area can cause the approval of the
entire system to be denied.
The proposed installation will not affect the future development of the surrounding or
existing lots. There are no wells or septic systems within 100 feet of the proposed septic
location.
If you have any questions or concerns, please contact me at 227-3522 or 272-8218.
Sincerely,
Steven R. Pannone, P.E.
Civil Engineer
Attachments:
C:\W0RK\LETTERS\14A-3H RABBIT CREEK HTS.DOC
PERMIT NO: DESIGN DRAWING
WASTEWATER DISPOSAL SYSTEM
LOT 14A BLOCK 3H RABBIT CREEK HTS
DITCH.
I\
0
2%J 100' OFFSET TO \
EXISTG CREEK—�
113
LOT UNDEVELOPED
NO WELLS OR SEPT,
WAN 100 FEET 8T
/ \ID\ LOTUNDEVELONO WELLS OR
WAN 100 FEET
Steven R. Par
CE
.., CE 8 zlg
�..
\WELL
PROPOSED 3 \
SR HOUSE
i
P.I.D. NO: 020.541-22
n
v \
15
PROPOSED 10009
y SEPTIC TANK \
•\ \\!� 10.0 PROPOSED RESERVE SAS
15LFx15Wx0.5 ED, M
\ Y0.1 INSTALL NEW 15009
Y ADVANTEX TANK WIAX20
POD
PROPOSED PRIMARY SAS
PROPOSED 60LFx25W4.5 ED. 17D
'--EXISTG DRAINAGE SUBDRAIN
DITCH. \SEE DETAIL
LOT UNDEVELOPED
\ NO WELLS OR SEPTIC
WAN 100 FEET
\
DESIGN CALCULATIONS:
=RAE
\
PERCOLATION MPI
\
APP RATE 0.3 GPDSF (500 S R
BEDROOMS:3
\
1,500 SF REQUIRED
\
BED 25W x 60 LF
MIN SIZE TANK -10009
)TES:
3) Maintain 10' separation to all 6) The house shall be located In
All work shall be performed
lot lines and proposed water the location shown.
accordance with
Ones. 7)11 the house needs to be
dC15.65.
4) Lots served by a private well. moved Into the septic area,
Materials used shall be In
No wells within 100' of proposed thesystem type shall be changed
xordance with those
system. to an Advantex System.
,ecified In AMC15.65.
5) Reserve field size based on
astewater Disposal.
use of Advantex System.
EPARED FOR: PANNONE ENG. SVC, LLC
Harland & Sandra Hannon P. O. BOX 102954
373 N. E. 173rd Street ANCHORAGE, ALASKA 99510
North Miami Beach, FL 33162 227-3522 P, 272-8218 Fax
(305) 651-3072
DATE: 12.14-05 PLAN
PERMIT NO:
DESIGN DRAWING DETAILS
WASTEWATER DISPOSAL SYSTEM
LOT 14A BLOCK 3H RABBIT CREEK HTS
P.I.D. NO: 020-541-22
-It
�
e
]Wllgl.•]..
I
w
PP
aw
F
N
„ 0O
a
§
F
_
a
------------
l
0
0 o e r,..nWv.o
��s
�8 uwwno
1
ua.m>
•ou.a+a.
♦i
�.... ............s.....
PREPARED FOR:
PANNONE ENG. SVC, LLC
,Steven R Pannone .0Harland
•
b Sandra Hannon
E. 173rd Street
P. O. BOX 102954
♦♦�
CE 6149
♦♦♦ •.,,i•�c7n/L�•••��
373 N.
North Miami Beach, FL 33162
ANCHORAGE, ALASKA 99510
Fax
♦-® ^�.......iA
(305)651-3072
227.3522 P. 272$218
♦♦♦, CF......�
ESS��Dl ••
12NTS 5 DETAILS
�,
SCALE:
PERMIT NO:SW04 DESIGN DETAILS
WASTEWATER ABSORPTION SYSTEM
LOT 14A BLOCK 3H RABBIT CREEK HTS
P.I.D. NO: 020-541-22
FRENCH DRAIN SEC ION
DESIGN CALCULATIONS
RESERVE SYSTEM ONLY
Number of Bedrooms - 3
Total Bedrooms -3
Design Now -150 gal/br/day,
Total Now - 450g/day
''7'. • 9
{x;7 49TM ri
...............1...
Steven R. Pannone.
1-11
)No. CE 149 - 4
TANK SIZE:
1500 gallon Advantex tank
SOIL ABSORPTION SIZE:
Advantex Sewer System
AX20 Pod - Class III System
Perc Rate= 40 min/inch
Application Rate= 2 GPD/SF
Size Required= 450 GPD/2 GPD/SF = 225 SF
Use bed, 0.5' effective
15' Long by 15' Wide
15 LF x 15Wx 0.5'ED = 225 SF Total
Harland d Sandra Hannon
373 N. E. 173rd Street
North Miaml Beach, FL 33162
(305)651-3072
PANNONE ENG. SVC.
P. O. BOX 102954
ANCHORAGE, ALASKA 99510
272-8218 PHONE & FAX
DETAIL
SOILS LOG - PERCOLATION TEST ����� ������♦
PANNONE ENGINEERING SERVICES +��P♦♦
P.O. BOX 102954 i3 49 TH °:♦♦i
�...... ..... .. ...........%.....♦
ANCHORAGE, AK 99510 0 ' 0
(907) 272-8218 ........... ...... ................
1♦'.Steven R. Pannone
♦ .' CE 8149 .
PERFORMED FOR:
Harland 8 Sandra Hannon DATE PERFORMED: 4130105 ♦♦♦.Od;�7/��,.,.�,,•yy�
LEGAL DESCRIPTION: LOT 14A BLOCK 3H Rabbit Creek His SID •�illill
TEST HOLE 1
SLOPE / SREPLAN .
IN
1 OR Organo nn
13
2
ML Gray/Brown SILT `
3 Wrrmce Sand-
C,
FF
5 Bandy W Silly 14 � �-
GM GRAVEL wIMSA
8 W. Hard digging .
1OcY O li
7 THI
15
ML Gray SILT tight LB
9
TEST
10 HOLE
BOH
" 16
12 /
13
WAS GROUND WATER SLOPE
14 ENCOUNTERED? Y (2005)
1s IF YES, AT WHAT TEST HOLE
18 DEPTH? -8'
17 DEPTH TO WATER AFTER
MONITORING? -3.1'
18 DATE: 5.15.2005
@-3.5' ON 10-15.2005
19
READING DATE CLOCK WATER
20
PEROLATION RATE 40 (mlMnch) PERC HOLE DIAMETER 6 inches
TEST RUN BETWEEN 2.5 FT AND 3.5 FT
COMMENTS: Test hole excavated by Dan Beeks. Test Hole was presoaked before pert test
PERFORMED BY: Steven R. Pannone, P.E. 1 CERTIFY THAT THIS TEST WAS PERFORMED IN ACCORDANCE
WITH ALL STATE AND MUNICIPAL GUIDLINES IN EFFECT ON THE DATE OF THIS TEST
TIME NET TIME LEVEL NET DROP
READING
1/30/05
8:58
S"
0-
2
9:28
JO MIN
{ 1/2-
1 1/2'
J
9:28
8-
0-
1
9:58
JO MIN
4 1/2-
1 1/2'
S
9:58
8-
0"
8
10:28
JO MIN
1 1/2-
1 1/2-