Loading...
HomeMy WebLinkAboutTHE VILLAGES-PINE RIDGE LT 9The Villages Pine Ridge Lot 9 #020-291-46 Municipality of Anchorage On-Site Water and Wastewater Program • (907) 343-7904 Page of ON-SITE WASTEWATER INSPECTION REPORT Permit Number: OSP181092 PID Number: 020-291-46 Dwelling: ® Single Family (SF) ❑ Duplex (D) ❑ Multiple (SF and/or D) Project: El New ® Upgrade Name: THOMAS & REGINA DIETRICH ABSORPTION FIELD Address ❑ Deep Trench ® Shallow Trench El Bed [' Mound 19100 PINE RIDGE CIR., ANCHORAGE El Other Phone Number of Bedrooms Soil Rating Total depth from original grade 3 1.2 GPD/SF 4 Ft. LEGAL DESCRIPTION Depth to pipe invert from original grade Gravel depth beneath pipe Subdivision Block Lot 1.5 Ft. 2.5 Ft. THE VILLAGES-PINE RIDGE 9 Fill added above original grade Gravel length Township Range Section Varies 1.94 —2.18 Ft. 48 Ft. Gravel width Beds:Number of Lines Distance between lines SEPARATION DISTANCES 5 Ft. Ft. To Septic Absorption Holding Sewer Total absorption area Number of trenches Dist.between trenches From Tank Field Lift Station Tank Line 375+ Ft2 1 -- Ft. Well -- 100'+ -- NA NA TANK ❑ Septic ® S.T.E.P. 0 Holding ❑ Other Manufacturer Capacity Gal. Surface Water -- 100'+ -- NA EXISTING STEP . Material Number of compartments Lot Line -- 10'+ -- NA NA Foundation -- 10'+ -- NA LIFT STATION Manufacturer Capacity Curtain Drain NA *50'+ NA NA -- -- Gal. Pump on level at Pump off level at High water alarm at Remarks *None known. Existing field removed & replaced per code / permitted design. in. in. in. Pump make and model Electrical Inspections performed by PIPE MATERIAL House to tank 3034 Tank to 3034 Installer A+ Home Services drainfietd Drainfield 3034 Co/MT 3034 Inspector ARCTERRA BENCH MARK (Assumed elevation) 100 ft Inspdates:ection 15 `5/25/18 2ne 5/25/18 Location and description 3'°5/25/18 4" 5/25/18 Bottom of door sill COMMUNITY DEVELOPMENT DEPARTMENT APPROVAL Engin 0 ' AL \ Conditional Approval: Date `S ' `4..��� � 1 *'49TH* Age * ) Arrw.......47,fr, # - ................,.... , KENNETH M.Of / r 7 1a F --ZT 1F 1 Approv-. t.,,... . `�.. Date S ,1%F> ,r F. ion'��.``i Ilk\`+4111' eer's Stamp Inspection Report_9-1-12.doc AS-BUILT SYSTEM DETAILS/SITE PLAN Pe-reit DSP181092 THE VILLAGES - PINE RIDGE LOOT 9 PID# 020-291-46 o EX\.NOUS- w \ 1 $ �: 3 3- a 0 0 54.3 i" i C0180 (0 LOT 9 ,°E A 2°!ANS p,.;xw� inCO EXISTING Ai n`�� 0 v 41114:C1250—GAL STEP s�qn 1 " r:.►11r=• d MH sliIl, ‘t tO NR�N D‘SCH 1996 TH#1 \ AO IC> // MT ------ SCREENING ES REMOVED & REPLACED EXISTING Fl LD O Z W/ 46' LX 5' ED LO 0 T TRENCH O '43c. D -PP- 0 1996 TH t3 c0 W E T RJ 1996 TH#2 �1, c201•10 200• c:t CP N'S 26' 53„E \ °° LOT 2 SCALE! 1' = 30' u v cc 2 101 LO IA tr-A-C=.112.,os g = q B-C= 5(0.0' W °A-D= 43.a' _ - C106.3� FINAL GRADE _ C106.0�- 104.2-v y o .�B-D=.7o.s _ 1 Di1GNOL(RADE VARIES SA-E=1'9.s' A �.,ER FA Q --'EXISTING '''. T B—E=.$O,O y 1250-GAL 102.6” (102.6 - 'v STEP SEWER ROCK 2.5' 714113 2 1/29/1996 IZ 100.1 I 94.15 MOA APPROVED SAND 1.5'+/- (3.15„) DEB' a ___` I 48' I c" OF Az \ SCALE! NTS W / �� • 4.6 1 PREPARED FOR! gCTERh' Ar�� 1 THOMAS & REGINA DIETRICH 1 / ��� "7 A 19100 PINE RIDGE CIRCLE ��' "i4 )1\ 'eo * .4 9 TH /\ * ANCH❑RAGE,AK 99516 `��907-441-6334 v / _ Ad at / • '*0r D ` • FIELD BOOKS ooMPU1ED: Q ` F2C)L''- 18 �,w�' I BOUNDARY:N/A ORANN: BMW Z 4" 1 L' S�o?7 !8' / STAONG N/A CHECKED: KMD ta ) \ 1� ASBUILT: SLS DATE: 5/26/18 I�•••"'-•1'"- 06 d \\ FESSo E _� D . FILE: GRID: 3637 lt. 004 i�G��\ `_ "CAD FlLE: FILE JOB No.: 18-143 '4,4.4, AK,99571• JN`�-,Pn"TYO MUNICIPALITY OF ANCHORAGE On-Site Water&Wastewater Program Awe, PO Box 196650 4700 Elmore Road ` Anchorage,Alaska 99519-6650 Phone:(907)343-7904 Fax:(907)343-7997 http://www.muni.org/onsite Depart mcnt NC Ii O R 1Vt On-Site Wastewater Disposal System Permit Permit Number: OSP181092 Effective Date: 5/22/2018 Work Type: Septic Upgrade Expiration Date: 5/22/2019 Tax Code Number: 02029146000 Site Legal Address: THE VILLAGES-PINE RIDGE LT 9 G:3637 Site Mailing Address: 19100 PINE RIDGE CIR, Anchorage Owner: DIETRICH THOMAS E JR & Lot Size in Sq Ft: 40000 Design Engineer: ARC TERRA CONSULTING INC Total Bedrooms: 3 This permit is for the construction of: Q Disposal Field ❑ Septic Tank ❑ Holding Tank ❑ Privy 0 Private Well 0 Water Storage All construction shall be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80) 3. The wastewater code requires inspections during the installation. The engineer shall notify the Development Services Department per AMC 15.65. Provide notification by calling (907) 343-7904 (24/7). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather shall be either: a. Opened and Closed on the same day, or b. Covered, sealed, and heated to prevent freezing • Received By: ," Date: ZL �2 Issued By: AL Date: 5AF/6 Or ‘IP. MUNICIPALITY OF ANCHORAGE •Community Development Department Phone: 907-343-7904 Development Services Division Fax: 907-343-7997 On-Site Water & Wastewater Program ON-SITE SEWER/WELL PERMIT APPLICATION Parcel I.D. 020-291-46 THOMAS & REGINA DIETRICH 907-441-6334 Property owner(s) Day phone Mailing address 19100 PINE RIDGE CIRCLE, ANCHORAGE, AK 99516 Site address 19100 PINE RIDGE CIRCLE, ANCHORAGE, AK 99516 Legal description (Sub'd., Block & Lot) THE VILLAGES-PINE RIDGE LOT 9 Legal description (Township, Range & Section) Lot Size 40,000 Sq. Ft. Number of Bedrooms 3 APPLICATION IS FOR: APPLICATION IS AN: TYPE OF DWELLING: (® all that apply) Absorption Field t Initial I I Single Family (SF)(w/wo ADU) Septic Tank ❑ Upgrade Duplex (D) n Holding Tank LJ Renewal I IMultiple Dwellings I Privy n (SF and/or D) Private Well ❑ Water Storage THIS APPLICATION INCLUDES A VARIANCE I WAIVER REQUEST FOR: Distance: I certify that the above information is correct. I further certify that this is in accordance with applicable Municipal Codes. (j . re property owner or authorized agent) Permit/Rush Fees: CS • Waiver Fees: Date of Payment: 5/i a/l8 Date of Payment: Receipt Number: n Receipt Number: Permit No. oSF I" 1012 Waiver No. PermitApp_9-1-12.doc ' �RCTERR9 • ARC TERRA 1R CONSUL'T'ING, INC �`..E S „No.•;;;��� 212 E. 51st Ave,Anchorage,AK. 99503 Office(907)868-3791, Fax(907)868-3793 May 16, 2018 Municipality of Anchorage Development Services Department On-Site Water & Wastewater Program P.O. Box 196650 Anchorage, AK 99519-6650 Subject: Upgrade Sewer Permit—THE VILLAGES-PINE RIDGE LOT 9 It has been determined that the absorption field of the subject property is saturated. Subsequently, the owner has requested we proceed forward to obtain a septic permit to upgrade the septic system. The general slope of this lot is from southeast to northwest at a grade of approximately 7-12% over the septic area. We are proposing to remove and replace the existing field per the attached design. The property and adjacent lots are served by private water. There is no surface water within 100' of the proposed system and there are no known curtain drains within 50'. We do not expect there to be any adverse effect on adjacent lots by the development of this system. If you have any questions, please contact me at 868- 3791 / FAX 868-3793. Respectfully submitted, ArcTerra Consulting, Inc. Kenneth M. Duffus, P.E. Attachments: On-Site Sewer Application Wastewater Absorption System Details/Site Plan 20441 PTARMIGAN BLVD • EAGLE RIVER,AK 99577-8736 • PH(907)868-3791 • FAX(907)868-3793 WELL & WASTEWATER DISPOSAL SYSTEM DETAILS/SITE PLAN THE VILLAGES — PINE RIDGE LOT 9 \ / / / y1 b e.RC .. b :1, 10 \ 6 /I�ttttl\ ''' Ili . ctirei '• 4lNIat ;.- Mir. . . I A • It LOT II a / 1 1.-.."-- V UP= \ 3 1 \ \ X \-- W FLAG PROPERTY LINES Scale. 1°= 100' WELL RADII & EASEMENTS PAGE 1 OF 2 PRIOR TO CONSTRUCTION DESIGN DETAILS 0 GPD = 450 GPD cr 450 GPD/1.2 GPD PER SQ. FT. = 375 SQ. FT (375 / 5 x .64 RF (2.5' ED) = 48 FT. TRENCH a USE 1 TRENCH - 48' (L) X 5' (W) X 2.5' (ED) i Total depth of system Is 4' max from original grade, o Total depth of gravel below distribution pipe Is 2.5' . REMOVE & REPLACE' REMOVE ALL BI❑MATTED MATERIAL & INSTALL WITH MOA NO PUBLIC WELLS WITHIN 200. OF APPROVED SAND PRIOR TO INSTALLING FIELD PER DESIGN SPECS. a' NO PRIVATE 73 DPOSED YWELLS WITHIN 200' OF STEM. NOTES: PROPOSED SYSTEM EXCEPT AS NOTED. 1. CONNECT TO EXISTING 1250-GAL STEP. l' 142oZIT WELL EXCEPT AS NOTED. 2. INSULATE TRENCHES WITH 2' HD BURIAL FOAM IF < 3' OF FILL. MIN. 2' FILL WITH INSULATI❑N, >3' COVER NO INSUL REQ. c. 3. CONTRACTOR WILL ENSURE MINIMUM 2% SLOPE INT❑ SEPTIC TANK. I 4. CONTRACTOR WILL ENSURE ALL SEPARATIONS TO ADJACENT WELLS, SEPTICS EASEMENTS, PROPERTY LINES, ETC... 41 OF A\ Air�S• •�,��1 PREPARED FOR: RCTER DD THOMAS & REGINA DIETRICHf[� v A 19100 PINE RIDGE CIRCLE4,401, 114 sr ° ;* .49 i\ . * A ANCHORAGE,AK 99516 . ��� �_ , 907-441-6334 a '� co 2 I • iN --'D # - ELD BOOKS COMPUTED: i ` CE- �,wa' / BOUNDARY:N/ DRAWN: BMW i ' �,.,I . 1�G' testi$ STAKING: N/A CHEa®: KMDco % '1 k -ii,.��. . / ASBUILT: SLS DATE: 5/15 18 • ..........40—\ / C `w1EsSIO� � 0 \\ '� DWG.FILE: crno: 3637 (.�00I l�C`cip `` ACAD FILE`FILE JOB NQ' 18143 SFR, K.99577''6 WASTEWATER DISPOSAL SYSTEM DETAILS THE VILLAGES - PINE RIDGE LOT 9 W C) ,- \ 0 50' Y PAVED D/W \ �in � 0 ` 0 N \ 54.3 (22 -1? te9ie \ (J! • }„aomoArro, ` EX I1Np SE \ \ Npv o.(= lilS) -'e.'”3o�� gj' 54.3 , i C018A 19.cL \ 10 LOT 9 1110'�cK °- 2iP S CO EXISTING \ \ �O 1250—GAL STEP N.. tcpsMH \ \ Try 1996 TH#1 R • OC"` s \ 0 0.0 A R% / �i 5 REEN`NG v 1996 TM�J'2 •EMOVE & R LACE z • EXISTING Fl LD rndol \ \ • ? rn ,, 1177M 1996 TH#3 to ;s3 CA ET R) Z (20 .10 3"E 200. 1 q °' GT ,,3,,E. / N15.26 • ao ✓ LOT 2 0 7) u • Scale: 1'- 30' PRESSURIZED DISTRIBUTI❑N SYSTEM HOLE SPACING DESIGN a 1. RESIDUAL HEAD = 5' LZ PAGE 2 OF 2 2. HOLE SIZE = 3/16' = 1.00 GAL. PER HOLE @ 30 PSI 1 3. 30 GALS (PUMP DELIVERY)/1.00 GALS./HOLE = 30 HOLES o 4. 135 LF LATERAL/30 HOLES = 1.3' SPACING PER HOLE Q_ LAJ 116:1‘1►:‘,\ 5. ALL HOLES SHALL HAVE CAPS INSTALLED PER MANUFACTURES SPECS. mimi %oc' O•• <Q,& PREPARED FOR: gCTER 3 �� ' THOMAS & REGINA DIETRICH A, A �� `� 19100 PINE RIDGE CIRCLE I s41 o61:• /* .4., Til ,� , . * I ANCHORAGE,AK 99516 / �� '` , 907-441-6334 7� \ 16;- I, • S FIELD BOOKS COMPUTED: �22 � x 4. a 4. E ` ' C 71 "if I BOUNDARY:N/A DRAWN: BMW z !`� R, 1 s4,/5 ,f A. STAKING: NSA CHECKED' K M D _ % \ / `:In' \X FESSIOItNS' ASBUR.T: SLS DATE' 5/15/18 •..�Fc, ��� \ _� DWG. �: GRID: 3637 (FR co,,,,. 1lyCSULTING ',rye,`9o�-) Z `` AGAR FIE FILE JOB"°: 18-143 fF•• 995n— / - 1 'Zg'S3E r 1 N75 J , / 'S `Y 26 1 / / C2' G6 tf) \ / oo , 1 1 .�/ / q!). 1(?) o• \ \ \ WELL o \ / / \ 2Sq 1 'Cr,w 1 rn \ �N �1o 1 � 44.d \ . CPt W1/ ES, \ (.71. 50' a? 40 rcl \ 1 PAVED O40 D/W e IQ �N 54.3 4,`•DECK 1 01. � / // 42.6 0 v o .P 0. Iliii E.\i`\ \\\1G : 1 i 18.0 F9• 1.00 DO( - 20.5 0 0, CAMS O • 1 c5 •0 MH �� LOT 9 1 1 N \ P _ 5p0 / .REEM ...----r6 ESM 1 SEPTIC • VEVT 1 (typ) \ (.0 O -P W CA= Ad R) cs) 411 (2-0AN�5.26'53 E 200' G0 N --L-013--8— aw LoT 2 ANCHORAGE RECORDING DISTRICT,ALASKA ASBUILT OF: THE VILLAGES V- PINE RIDGE LOT 9 PLAT 79-255 _+_`"\\ SURVEY CERTIFICATE:I,John L.Schuller,Have conducted a i O F 4 \\` 'y4 LAW"�� physical survey of this property as shown on this drawing and that the / �..••'''' •. - 1t �4. \0 S improvements situated hereon are within the property lines and no /�(s • `) S ' w� � enchroachments exist other than noted.Under no circumstance should / .' 49TH \ . '' N O ••-' 0 any information on this drawing be used for construction of fences, a , . r structures,improvements,or for establishing boundary lines. r EXCLUSION NOTES:It is the owners responsibility to determine I,m . A J N L. SCHULLER.' o:• , the existence of any easements,covenants,or restrictions which LS-10408 A,40 do not appear on the recorded subdivision plat. rX tea'/ •�• ...•�" etna Street WORK ORDER NUMBER: DAIS: SCALE: E-4NL• '' eo '.. •. .1$•• n5i/� An1cchorage,31 eA1 Alaska 99508 APR 28, 2018 1'=30' 1` p • n 1 8—023 BRAMN BY:CBEa(m BY CFD I&I , BOOK/PACE X�'ofessionaA =.�r (907) 227-1455 office JLS 3637 180137 \\N���� (907) 274-4992 fax Municipality of Anchorage Page I of? ' DEPARTMENT OF HEALTH AND HUMAN SERVICES ENVIRONMENTAL SERVICES DIVISION P.O. Box 196650 • Anchorage, Alaska 99519-6650 • Telephone: 343-4744 On -Site Wastewater Disposal System and/or Well Inspection Report Permit Number: Sw Is 6 00 15 PID Number: oz0 - za 1 -Y 6 Name: Wastewater System: ;9 New ❑ Upgrade R.a O,xe Address: ABSORPTION FIELD • f. o. ox -773%7'1 E Rvdac INC. -11191'7 Phone: SLZ -n7o No. of Bedrooms: 1 3 D Deep Trench IH Shallow Trench O Bed O Mound D Other LEGAL DESCRIPTION Soil Rating: I Z Total Depth fs riglnal grade: PD/ Ft Lot: Block: Subdivislon: Depth to pipe bottom from original grade: Gravel depth beneath pipe Cl -ME 4ILLa," - PnIfE R,ncr 2e Ft. 3.5 Ft. Township: Range: Section: Fill added above original grade: Gravel length: )--2- Ft Ft. WELL:IQ New ❑Upgrade Gravel width' Number of lines: I Daana be ween anee � • Ft. Ft. Classification (Private. A.B.C): Total Depth: Cased To: Q R Total absorption area: y01 Pipe material: A T 7 n PKI•!A'CE 3 'y Ft. ;l 0 Ft. SO. Ft d 3-4 AvC Driller. Date Drilllad: static Water Level: Installer. p $- So. Date installed: ♦ / �y / 9 G {O ALrf,ve DRnLLIIv(r 3/)'1)96 1'i Ft. Kt-f,;.o .s Yield: Pump Set at: I Casing Height Above Ground: TANK K 3 GPM V /K Ft. 1 i Ft. SEPARATION DISTANCES ❑Septic ❑Holding IRS.T.E.P. To Septic ADWrptlorl Lift Holding bikJPdvete Manufacturer. '14.1 Capacity In gallons: 1�•'S� From Tank Fwd Station Tank Sr Urom ewe AN, e1G A0RAGG 1 Material: Number of Compartments: Welt �c," 1001+ /DOf•1• 2S4 S -M 2 Surface -- LIFT STATION Water loo loo'* Lot ( 1{, 1-� Size In gallons: Manufacturer. CRCwco Svzrvnj T Line 65 l0 1250 ASM C Ha AAc[ - Foundation Cje-0-44 �- 'Pump on" level at: "Pump otr level at: „ High water alarm at: Curtain _ - 1 Pump Make & Model EleeMcal mepectiona performed by: O. q• Drain SI eSNN BENCH MARK Remarks: PaEsfi„xnteo Olsr.tra�rre.✓ 1-1.4E 30 IAr,014. U er/J Location and Description: 'fRM = CoRrlep.. of= OeuL N,tS Naa{ S �aever4 4r- I.y'O-C, L4T"41L In Assumed Elevation: 100.E S%tL = I DIS. FtE a f INOINteRING G _ •� _ q[ . •• I• Inspections performed y &.9011i rN- 2aftDates:1st 6-14-96 .}}}}}}._.. A ROBERT C. COWAN � hRiver,Alaska"STIF 2nd .^` �rti.;,OE'a..01 3rA 12 Department of Healt and H a ices approvaT— •-• "". �'= Reviewed and approved by: ate: v 1 72-013 IRev. 9191) MOA 25 V r Permit No. 6w 9 L oo ($ Municipality of Anchorage Page 2 of 2 DEPARTMENT OF HEALTH AND HUMAN SERVICES ENVIRONMENTAL SERVICES DIVISION P.O. Box 196650 • Anchorage, Alaska 99519-6650 • Telephone: 343-4744 On -Site Wastewater Disposal System and/or Well Inspection Report Legal Description: LOT 9, THE VILLAGES - PINE RIDGE PIDNo.: pzo -Z91 -462 A \ WELL ` B FCO 46' 4' \ IOD, ADS ST1 38. 15.5' ST2 35' 20.5' MH 34' 21.5'Uzi 77' � � a MT2 83' T 2 ASS •C* '.Ll W DECK \ N A � 1 ,G % 3 � 6 USE z 1` it ALT SITE 5T1 \ I\ ` ��G r H S T. SYSTEM .P? / / \ ENI PRESSLI IZED //// Y1F TRENCH `` jo ACP /ATH#1 #3A " \ i00' Sv `1 r - 40• ATHj 2 .. MT. MT .. •j 106.4'. 106.6' _ SCALE STI ST2 FINAL GRADE MT E OF A(' 94.1' MH4 y"�P -. �N _...:__..�7 ;!;; ;�--• A ROSE Rr c COWAN G .T.E.P. 10 3'(LEVEL) SYSTEMCE-8801 - �tittJ�`i1L'i'i'���~ MT2 99.3' ♦94.3' 72-015 A(R". 9AI) MOA 25 B.U.H. as.a 9075638453 PfiRKb y ATRIUM ELIILG MAR 1819% ri •., 251 P02 JUN 20 '96 10:05 STATE OF ALASKA DEPARTMENT OF NATURAL RESOURCES DIVISION OF MINING & WATER MGMT WATER WELL RECORD LUca I IUrt Ur vrcu eorlouoN ve• LOT eocK acrna+nTMs xcxxT OMsron � ON EIS Ow LOCATION/SKETCH: Y WELL OWNER: DEPTHS MEASURED FROMMcasing top Elground surface WELL DEPTH: ATE OF COMPLETION Depth of hale: 3C 1t it BOREHOLE DATA! Depth Depth of easing: Material Type and Color From To DEPTH TO STATIC WATER LEVEL: zk —Ule[� 7 t below )M top of casing IJ ground surface Date: -5 IP•16;7 ? r.' METHOD OF DRILLING: t5air rotary 11 cable tool ❑ other USE OF WELL: Qdomestic ❑ Irrigation O monitor 13 public supply ❑ other CASING STICKUP: '� ft. Dam: 6 in. to'V t Casing type: in. to F_ot WELL INTAKE OPENING TYPE: 0 open end O screened . Sd J O perforated 0open hale Depths of openings: t0 it 360 yy 36 SCREEN TYPE: Diam: in. Slat/Mesh Size: Length: It GRAVEL PACK TYPE: Volume used: Depth to top: GROUT TYPE: Volume. Depth: from it to It VE NT MET OD: UH 21 �n.. ['490 EVEL AND�(IELD: i t atter hrc pumping gom kPUMtP •''r9aith8 ) " KE DEPTH: ft Horsepower. ti FECTED UPON COMPLETION? irYES O NO REMARKS: PLEASE MAIL WHITE COPY OF LOG TO: DNR/ONISION OF MINING & WATER MGMT 3601 C St, Suite 800 Anchorage, Ak 99503-5935 Ph(907)762-2538,Fax(907)562-1386 PAGE 1 OF • MUNICIPALITY OF ANCHORAGE p DEPARTMENT OF HEALTH AND HUMAN SERVICES /� (�'.- P.O. BOX 196650, 825 "L" STREET, ROOM 502 rAl ANCHORAGE, ALASKA 99519-6650 1111100000 __ ON-SITE WELL AND WASTEWATER DISPOSAL SYSTEM PERMIT LO -OL -OlV 1�0M PERMIT NUMBER:SW960015 DATE ISSUED: 1/39/56 DESIGN ENGINEER:S & S ENGINEERING EXPIRATION DATE: 1/30/97 OWNER NAME:SWIFT MARLENE L SQ(Y\ OWNER ADDRESS:19100 PINE RIDGE CIR ANCHORAGE, ALASKA 99516 �-10 cru PARCEL ID:02029146 LEGAL DESCRIPTION: THE VILLAGES -PINE RIDGE LT 9 LOT SIZE: 40000 (SQ. FT.) NUMBER OF BEDROOMS: 3 THIS PERMIT: 3 THIS PERMIT IS FOR THE CONSTRUCTION OF: DISPOSAL FIELD /SEPTIC TANK / WELL SYSTEM ALL CONSTRUCTION MUST BE IN ACCORDANCE WITH: 1. THE ATTACHED APPROVED DESIGN. 2. ALL REQUIREMENTS SPE�ZIFIED IN ANCHORAGE MUNICIPAL CODE CHAPTERS 15.55 AND 15.65 AND THE STATE OF ALASKA WASTEWATER DISPOSAL REGULATIONS (18AAC72) AND DRINKING WATER REGULATIONS (18AAC80). 3. THE ENGINEER MUST NOTIFY DHHS AT LEAST 2 HOURS PRIOR TO EACH INSPECTION. PROVIDE NOTIFICATION BY CALLING 343-4744 ( 24 HOURS ) . (NOT REQUIRED FOR WELL ONLY PERMIT) 4. FROM OCTOBER 15 TO APRIL 15 A SUBSURFACE SOIL ABSORPTION SYSTEM UNDER CONSTRUCTION DURING FREEZING WEATHER MUST BE EITHER: A. OPENED AND CLOSED ON THE SAME DAY B. COVERED, SEALED AND HEATED TO PREVENT FREEZING 5. THE FOLLOWING SPECIAL PROVISIONS. SPECIAL PROVISIONS: RECEIVED BY ISSUED BY: Z' � DATE: 11,30116 DATE • / — 3 U ' 7� 1 January 26, 1996 ROBERT C. COWAN. P.E. ROBERTA. SHAFER, P.E. CML ENGINEERS (907)694.2979 FAX(907)694-1211 MUNICIPALITY OF ANCHORAGE Department of Health and Human Services P.O. Box 196650 APPROVAgfNOitlTM Anchorage, AR. 99519 REFERENCE: Lot 91 The Villages -Pine Ridge MAINORErSara This is to resubmit our request for a permit to drill a well and install a septic system to serve the proposed three bedroom house on the referenced property. A separation distance waiver to the class "C" well located on SEWERBWATER lot 2 is no longer necessary. By copy of this letter, the INSPECTION State of Alaska Department of Environmental Conservation is notified of this waiver cancellation. Three test holes were excavated and percolation tests ENGINEERINGSTUDIES performed. The approximate location of the test holeSare ANGREPGRTS located on the attached site plan. At the time of excavation no water was encountered in test holes $1 and $2. Water was found at 10.5 feet in test hole WELL INSPECTION 6PLOWTEST $3. After five day ground water monitoring, the monitoring tubes was found to be dry for test holes 81 and $2 and water in test hole $3 was at 10 feet. SITEPANS This property has enough area for a future septic upgrade which can be seen on the attached site plan. We do not anticipate any adverse effects on neighboring ROAD DESIGN wells, septic systems or drainage patterns by the installation of the proposed septic system. There are no points of contamination within the proposed SOIL TEST well radius which can be seen on the attached site plan. If you require additional information, please contact us. PERCOLATION Sincerely, TEST i�ff.. Cowan, P.E. STRUCTURALS RCC/gk MED""T+ICAL Enclosure INSPECTIONS c: Alaska Department Environmental Conservation Attention: Mr. Michael Lu ONSITE WASTEWATER DISPOSAL SYSTEM DESIGN 17034 NORTH EAGLE RIVER LOOP • SURE 204 • EAGLE RIVER. ALASKA 99577 LEGAL z c� w w O J La r V) 0 U-) E VI DESIGN CRITERIA: 3 BDRMS = 450 GPD SOILS = 1.2 GPD/SQ.FT. 450/1.2 = 375 SQ.FT, REQ'D. REDUCTION FACTOR = 0.54 TRENCH DESIG 5' DEEP 3.5' EFFECTIVE 5' WIDE 41' LONG PRESSURIZED DISTRIBUTION SYSTEM: PUMP=20 OSI 05HH-5 STAGE( -30 GPM) V 1 LATERAL® 41' LONG 30 GPM/LATERAL 30 HOLES/LATERAL(1.2' O.C.) , 30 HOLES TOTAL = 1 GPM/HOLE i 4 1�4" DIA. HOLES FACED DOWNWARD Q; 1' DIA LATERAL LOT 2 U CLASS LOT 4 ALL PORTIONS OF SYSTEM WITH LESS THAN 3.5' OF COVER REQUIRE INSULATIC LOT 7 LOT IDGE SHT. STRUCTURES, EASEMENTS, OR ENCROACHMENTS�... ••• ,,..„ i'••• •• SHOWN ON THIS SITE PLAN ARE AS SHOWN ON S; � ANA 1 SURVEY DRAWN BY: '� .,% arear G cavae F IT IS THE RESPONSIBILLIITY OF�THHETCONTRRACTOR rye. f^� `CE•E601 rani TO VERIFY EASEMENTS, REQUIRED SEPARATION +, c DISTANCES, AND PROPERTY LINES PRIOR TO CONSTRUCTION. ALT. SITE DESIGN: SOILS = 1.2 GPD/SO.FT. 1' DEEP(1' ABOVE GRADE) \ , s 2'+ LAKE OTIS GRAVEL OR EOW \ G 0.5' EFFECTIVE 5- IDE \\1\ PROP. \1\ o 75' LONG \ ` WELL `\ % REDUCTION FACTOR = 1.0 \ r00. \ o \ \ \ N pROppSE g 9 3. �OV51, \� 7+,\ CC ,1 N 1 V INSTALL a \ \ SCO %, \ r. SITE \ ROPOSED 1250 GAL \CONTRACTOR IS \ S.T.E.P. SEPTIC\ TANK OBTAIN UTILITY UT v 11 \ 3-S�'PROPOSED TRENCH PRIOR TO ANY \ i � � WORK. Its, \ �\ CLIENT 1 \ \ LOT 8 REQUIRED LOCATES EXCAVATION �UGnILA Wl VYfI N( K:f>:M.. M •LP 4�{ c«.on4G 1En16tfiEER'S'SEALI Municipality of Anchorage I DEPARTMENT OF HEALTH & HUMAN SERVICES r?^ ` A 825 "L" Street, Anchorage, Alaska 99502-0650 SOILS LOG — PERCOLATION TEST %:••• n % RO£ER7 C. COWAN f' - PERFORMED FOR: '%O 14 0 E L U 1 KG DATE PERFORM E t�i IJF �ti /p,0 4 O LEGAL DESCRIPTION: L a T' 41 r„a. v,t.L4L4#5 –04'"4' Township, Range. Section: SLOPE SITE PLAN 4FEEF) ti 1 o• 2- 3- 4- 6 3 46 7• 8• 8 10 11 12 13 14 15 16 17 18 19 O A4.AJ, C.S GMIS M &/ZAvE C -i S)LrY S11 -15J C 0OAL4, 3 UP 13,0.//. REe..SAL Svi/'e1740 R403aCK WAS GROUND WATER ENCOUNTERED? IF YES, AT WHAT DEPTH? IV 0 DepN to Water After 44I /9C Monitaring7 p 4 7 Date: Reading Date Gross Time Net Time Depth to Water Net Drop ,� SVAK Jab a:S-o – y'z" – 7 :S'6 3 / G '/Z.., / 20 UPERCOLATION RATE � (minutes/inch) PERC MOLE DIAMETER TEST RUN BETWEEN 3 FT AND Al FT COMMENTS PERFORMED BY. S & S ENO Nrr iNG I j4j!S / 6!•f!= CERTIFY THAT THIS TEST WAS PERFORMED IN 17034 Eagle Rived / CI % ACCORDANCE WITH �kTRT&ANRl Sy 9KdR a;bW 204N EFFECT ON THIS DATE. DATE: 72-008 (Rev. 4/8.5) rc PERFG LEGAL 1 2 3 4 5 6 7 8 9 10 11 12 U 14 V tf 1. 11 V 21 TEST RUN BETWEEN FT AND FT COMMENTS FOR PERGG SL 4- TF -ST NOL(. HI -' SAM( 5 8 S ENCINEERING I -11-141-� CERTIFY THAT THIS TEST WAS PERFORMED IN PERFORMED BY: Eagle River LOOP Road No. 204 __ / a -q / C) It, ACCORDANCE WITWAgteR#,T*t %WJ 44*� GUIDELINES IN EFFECT ON THIS DATE. DATE- 72-008 ATE72-008 (Rev. 4/85) • •. . Municipality of Anchorage p�} DEPARTMENT OF HEALTH 8 HUMAN SERVICES r! '' \ 825 "L" Street, Anchorage, Alaska 99502-0650 SOILS LOG — PERCOLATION TEST ROBERT C. COWAN f PERFORMED FOR: PC Itj AJD E t. DIKE- DATE PERFORM Ea fD�rt•"�•!f',F?.-'- "ZZ`''.��...,o `yam ,rlj' R,OGE LEGAL DESCRIPTIONLpT R T'N �- v,,.cAcE s - P Township, Range, Section: r—� SLOPE SITE PLAN (FEET) 1 1 It I Lt + 2- 3- 4- 5 34 5 . • t� o F �I 7- 8- 10 8 10 O:s 11 12 13- 14- 15- 16- 17- 18- 191 3141516171819 20 COMMENTS O 0 (-A,-4i c .S SANny (,RAvjc t„/ s/t_T cossi.e S //.2R /°7L WASGROUNDWENCOUNTERED? ATER yE S R.O.l1. R, / IF YES, AT WHAT /O Suf/ric')L4 BEDRJCK DEPTH? Depth to Water Alter /p / /�dq �96 Monitoring? Date Reading Date Gross Net Time Time Depth to Net Water Drop /Z S K 3-1 Z ' S. 9 io,La_ '7 PERCOLATION RATE D- (mmutes/mCh) PERC HOLE DIAMETER TEST RUN BETWEEN y 1/2 FTAND S ,/Z FT S 1t, S ENGINEERING Y�+/.� �+ �i�� CERTIFY TH T THIS TEST WAS PERFORMED IN PERFORMED BY1 ate a Iver o0 Roado. t ACCORDANCE lGjTjle Rj rajjk fAND"8"IPAL GUIDELINES IN EFFECT ON THIS DATE. DATE: / 72-0081Rev. 4/95) ROBERT C. COWAN, P.E. ROBERTA. SHAFER, P.E. ON—SITE WASTEWATER DISPOSAL SYSTEM CMLE(907) 6944-2979-2979 RS CONSTRUCTION PRACTICES FAX(907)694-1211 and MATERIAL SPECIFICATIONS IEALTNAUTIgNTYAPPROVALS REFERENCE: Lot 9, The Villages -Pine Ridge January 25, 1996 GENERAL: SEWER& WATER MAINEXTENSION5 1. The scope of this project includes the installation of a 1250 gallon wastewater S.T.E.P. system (septic tank) and a five foot wide pressurized leachfield trench to serve the proposed three bedroom residence located on SEWERQWATER the referenced property. INSPECTION 2. Construction shall be in accordance with the approved site plan and design drawings, Municipal permit with any special provisions or conditions, and all ENGNEERINGSTLOES applicable State and Municipal Wastewater Disposal ANOREPORTS Regulations. 3. The contractor shall be responsible for obtaining any necessary underground utility locates. WELLNSPECf10N 8 FLOW TEST 4. Unless specifically agreed otherwise, the property owner shall be responsible for final grading areas subsequently depressed from soil settling. SITE PLANS 5. Contractors installing wastewater disposal systems must be certified by the Municipal Health Department for system installations. Owners installing their own RonoESICN systems must also receive prior approval from the Municipal Health Department. SEPTIC TANK INSTALLATION: SOILTEST 1. A septic tank is to be constructed by a certified septic tank manufacturer. Construction shall include two 4" cleanouts for pumping access. PERCOLATION TEST 2. The septic tank shall be sufficiently bedded to prevent settling or shifting of the tank. STRLCTUNLa 3. All standpipes on the septic tank shall extend a WIECHAICAL minimum of 12 inches above final grade. INSPECTIONS ONSITE WASTEWATER DISPOSALSYSTEM DESIGN 17034 NORTH EAGLE RIVER LOOP - SURE 204 - EAGLE RIVER. ALASKA 99577 Page Two Lot 9, The Villages -Pine Ridge January 25, 1996 4. Septic tanks installed with less than 4 ft. of cover shall be insulated. 5. A foundation cleanout shall be installed one to four feet from the building foundation. In the line between the tank and the leachfield there shall be two adjacent cleanouts (unless an effluent pumping system exists within the septic tank). These cleanouts shall be located on undisturbed soil not more than 10 ft. from the tank. The first cleanout, in line, shall be to clean toward the leachfield. The second cleanout shall be to clean toward the septic tank. 6. Final grading over the septic tank shall be such that a positive slope exists away from the septic tank. ABSORPTION TRENCH/DRAINFIELD INSTALLATION: 1. Excavate the proposed trench to the dimensions shown on the design. The bottom of the excavation shall be within 2 inches of level. If the sidewalls of the excavation become smeared, they must be raked or scratched (ruffed -up) before gravel (sewer rock) placement. 2. Once the gravel is installed, the distribution pipe is to be installed level with the holes faced downward. The distribution piping is to be of PVC (ASTM D3034 or equal). All joints are to be solvent cemented. Gravel is then to be placed over the distribution pipe to provide a minimum of 2 inches of cover over the pipe. 3. A silt barrier must be installed between the final gravel layer and the native soil backfill. Ensure the silt barrier covers the entire gravel surface before placing backfill. 4. Monitor tubes shall be of four (4) inch diameter, installed approximately in the locations shown on the design, and extend a minimum of 12 inches above final grade. The portion of the monitoring tube extending through the gravel shall be perforated from the bottom of the trench to the invert of the distribution pipe. This is equivalent to the effective depth of the gravel as noted on the design. Page Three Lot 91 The Villages -Pine Ridge January 25, 1996 5. Backfill over the final gravel layer must not be less than twenty-four (24) inches. Insulation must be installed when the backfill depth is less than thirty-six (36) inches. The finish grade over the trench must be mounded to prevent the formation of a depression after settling. MINIMUM MATERIAL SPECIFICATIONS: 1. Any septic tank proposed for installation must be constructed by a Municipally approved septic tank manufacturer. 2. The following pipe materials are approved for use in septic system installations in the Municipality of Anchorage: Type of Pipe Perforated Solid Cast Iron Yes Yes ASTM D3034 (PVC) Yes Yes ASTM F810 (HDPE) Yes No ASTM D2662 (ABS) Yes Yes Use of a type of pipe other than listed above must be approved by the inspecting engineer. 3. Insulation shall be at least 2" thick extruded direct burial polystyrene (Dow Chemical Company Styrofoam HI or equal). 4. Septic tank inlets and outlets shall be fitted with watertight couplings (Caulder, Fernco, or equal). 5. A permeable nontoxic silt barrier (Typar 3401, Mirafi 140N, or equal) must be installed between the final leachfield gravel layer and the native soil backfill. 6. All leachfield gravel (sewer rock) shall be 0.5"-2.5" screened gravel with less than 3% passing the $200 sieve. 7. When sand is being used as a filter material, its gradation specifications must conform to current M.O.A. or D.E.C. requirements. Page Four Lot 9, The Villages -Pine Ridge January 25, 1996 INSPECTIONS: Typically there will be a minimum of three (3) inspections required during the installation of the wastewater disposal system. These inspections will occur as follows: 1. The first inspection must be conducted after the excavation of ditches, pits, trenches, or beds and before the installation of any gravel. A septic tank may be set in place, but may not be backfilled before this inspection. 2. The second inspection must be conducted after the placement of the silt barrier, gravel, distribution lines, standpipes, cleanouts, and insulation, but before the placement of any other backfill. 3. The final inspection is to occur upon final grading of the property. Often there will be more than these 3 inspections required. Especially with the installation of multiple trenches, sand filters, pressurized distribution systems, etc. Thus, the inspecting engineer is to be contacted at least 24 hours prior to the start of construction. If necessary, a pre -construction meeting will take place on-site. The inspecting engineer will not coordinate, direct or control in any way the contractors activities. The owner shall contract with the contractor to perform the work outlined in these specifications and plans and in accordance with the attached M.O.A. permit. There will be no contractual arrangement existing between the contractor and S & S Engineering. S & S Engineering shall be the owner's representative and will inspect the work as stated above to document the contractors activities. Final acceptance of the contractors work rests with the owner and the M.O.A. Page Five Lot 91 The Villages -Pine Ridge January 25, 1996 S & S Engineering shall have no liability to the owner or to others for acts or omissions of the contractor or any other persons performing work on this project or the failure of the contractor to carry out the work in accordance with these construction documents. S & S Engineering's inspecting engineer will not be responsible for the construction means, methods, techniques, sequence, procedures or the safety precautions incident to this project. CONTRACTOR/INSTALLER DEPT. OF ENVIRON!HENTAL CONSERVATION ANCHORAGE/WESTERN PUBLIC SERVICE AREA OFFICE 555 CORDOVA ST. ANCHORAGE, ALASKA 99501 Mr. Robert Cowan TONYKNOWLES, GOVERNOR I✓='o - CY ' 1 -Ll W (907) 269-7505 December 29, 1995 RECEIVED S& S Engineering " JAN 2 1°1°It° Q M 17034 Eagle River Loop, Ste. 204 Nlwiic.pa!ity of Anchorage Eagle River, AK 99577 Dept. Health & Human Services Vi VJ RE: Lot 91,' -Villages -Pine Ridge Subdivision; Horizontal Waiver Separation Request From Class "C" Public Water System. ADEC Project No. 9621 -WV -348-030. Dear Mr. Cowan: This letter is in reference to the materials received in this office December 14, 1995, requesting a waiver from the required 150 foot horizontal separation distance between an on-site wastewater disposal system on the above the referenced lot and a neighboring class "C" public water system. The Department has completed its review of the submitted information which included a well log for the Class "C" well on Lot 4, soils percolation test logs for the above site, and a completed checklist for a request for waiver of separation distances system plan review checklist. Based upon this review it appears that from the information provided this well which is down gradient may be susceptible to contamination from a continuous source such as a leach field, however, this area has little development and there are no present indicators of groundwater contamination. Therefore, in accordance with State Drinking Water Regulations (18 AAC 80.030) and Wastewater Disposal Regulations (18 AAC 72.015) approval of the requested waiver for a lesser horizontal separation is granted subject to the following conditions: Satisfactory results from a raw water sample analysis for total coliform bacteria and nitrate for the well on Lot 2. These results will be used to establish background information for water quality in this area. 2. A higher level of treatment for the effluent from the wastewater disposal system is required for further consideration of this waiver to the proposed Class "C" well located on Lot 2. 3. If the on-site wastewater disposal system on Lot 9 or surrounding lots fail, the replacement system must be placed outside the 150 foot protective radius of this class "C" well. 0 Mr. Robert Cowan December 29, 1995 Page 2 This approval does not imply the granting of additional authorizations nor does it obligate any other state, federal or local regulatory agency to grant required authorizations. Thank you for your cooperation with this Department, if there are any further questions please do not hesitate to call. Sincerely, Michael Lu, E.I.T. Environmental Engineer cc: Jim Cross, DHHS/On-Site Well & Septic MLU/pt 7 :-, .. YILLAOSS AT 'PINE RIDDE - - -r- - - - - - - - - - - - - - - �tBIN 3. .3 :CORRECTIONS ESSENTIAL AS.. 3 Do Not CONCEAL UNTIL REIN -------------- 7 99 196 13:15 V Ktk� -1 JUL 101996 Municipality 0" kncnoragenServices DepLjiealth&Huma rl :51- ol. 4 DATE: -7_`x.6 ---------- --- UHEN CORRECTIONS ARE HAD19 PLEASE CALL POR INSPECTION DO NOT REMOVE THIS NOTICE Municipality of Anchorage REQUEST FOR VOUCHER CHECK FROM: DHHS, ESD, On-site Services (DEPARTMENT) TO: MUNICIPAL CONTROLLER DATE: JUne 28, 1996 R *;7dgq THIS SECTION FOR ACCOUNTS PAYABLE USE ONLY 1099 VOUCHER NO. PAYMENT DT. V I VENDOR NO. REFERENCE NO. INVOICE DATE INVOICE NO. DESC AUTHORIZED USE ONLY (t)Xi5XMA1LT0 PAYEE (6) D NOTIFY DEPARTMENT EMPLOYEE WHEN CHECK is READY IN FINANCE (2) D WILTO PAYEE W/ATTACNMENT (3) D NOTIFY PAYEE TO PICK UP IN TREASURY CHECK NO. CHECK DATE PREP APPA 1. REQUEST THAT A MUNICIPALITY OF ANCHORAGE CHECK BE ISSUED TO: Name S & S Engineering Address 17034 Eagle River Loop Road Suite 204 Eagle River Alaska 99577 2 THIS PAYMENT IS FOR THE FOLLOWING (SUBSTANTIATION ATTACHED): Please refund the following fee. The engineer, S & S Engineer notified this office that NBA was not requiring the Health Authority Approval Certificate to be completed on this property. Review and inspectionsrhave not been performed on this paperwork so a refund can be obtained 'Lot 9 The Villages -Pine Ridge S/ 3. DISPOSITION OF CHECK: AUTHORIZED USE ONLY (t)Xi5XMA1LT0 PAYEE (6) D NOTIFY DEPARTMENT EMPLOYEE WHEN CHECK is READY IN FINANCE (2) D WILTO PAYEE W/ATTACNMENT (3) D NOTIFY PAYEE TO PICK UP IN TREASURY Name: Name: Grg. No.: Phorr No.: Phone No.: 4. ACCOUNTS TO BE CHARGED: ITEM ENTER ALL POSITIONS OF ACCOUNTING DISTRIBUTION O t= Acct/ 'to" Opt I Cost Ctr. WA/WO NO. DESCRIPTION AMOUNT 1 i1ei.41 u o i o rak 2 70 94 6 1 11 11 1111 1 1 1 300.(D do S. TOTAL AMOUNT OF CHECK s 300. S. Employee 7. INSTRUCTIONS 43-4744 hone No. Approving Authority a. To be used only when payment cannot be made by purchase order. trawl expense report. travel authorization or Petty Cash. b. Must be approved by department head unless approvat authority Is delegated In accordance with Policy and Procedure 247. c. Retain Carbon copy for your fib. 40-001 (Rev. 2191) MOA 115 Municipality of Anchorage • -� DEPARTMENT OF HEALTH AND HUMAN SERVICES Environmental Services Division Telephone: 343 -4744 —. ------- ON-SITE SERVICES FEE DOCUMENTATION Date Paid: 6 'o2/— & Name of,Pajer.1Name on Check) Mailing Legal Type of Payment: (Ind/'pate Amo nt Paid) ��� health Authority: Ili( ^�'� Excavator Permit: Sewer & Well Permit: Engineer Permit: Well Permit: / "'? n • e."21 Pumper Permit: Sewer Permit: 3^� ' Well Driller Permit: Copy Request: 72-034 IRw. 10/87) _ Tank Manufacturer: (Waste Treatment) DISTRIBUTION: OS- 01857 Permit Number. Receipt #: 5 �� 7 !7 Check #: S!?1 / y WAIVERS: Lot Line: Well to Tank: Well to Field Field to Surface Water Tank to Surface Water WHITE -MASTER FILE CANARY -PROGRAM FILE MUNICIPALITY OF ANCHORAGE    DEVELOPMENT SERVICES DEPARTMENT    907‐343‐7904  On‐Site Water and Wastewater Section                                                                                           Fax: 343‐7997  www.muni.org/onsite         Mailing Address: P. O. Box 196650 * Anchorage, Alaska 99519‐6650 * www.muni.org      Septic Tank Advisory   Certificate of On‐Site Systems Approval # OSC201155  Subdivision:  The Villages ‐ Pine Ridge  Lot: 9  The septic tank for this property is 24 years old.  The average life for a steel septic  tank is 20 years. Typical replacement costs range from $7,000 to $11,000.   This advisory must be attached to all copies of the subject Certificate of On‐Site  Systems Approval.               This is an example of what the metal of a 30 year old steel tank MAY look like.      • bstt Municipality of Anchors _, 4'A,'@4= On-Site Water and Wastewater Program <';"'` (907) 343-7904 s ETY CERTIFICATE OF ON-SITE SYSTEMS APPROVAL Parcel I.D. 020-291-46 Expiration Date: 02� `rV 1. GENERAL INFORMATION Complete legal description THE VILLAGES-PINE RIDGE LOT 9 Location (site address) 19100 PINE RIDGE CIRCLE,ANCHORAGE,AK 99516 Current Property owner(s) THOMAS& REGINA DIETRICH Day phone Mailing address 19100 PINE RIDGE CIRCLE,ANCHORAGE,AK 99516 Real Estate Agent Day phone 2. TYPE OF DWELLING: ® Single Family (w/wo ADU) ❑ Duplex ❑ Multiple Dwellings (Single Family and/or Duplex) 3. NUMBER OF BEDROOMS: 3 TYPE OF WASTEWATER DISPOSAL: 4. TYPE OF WATER SUPPLY: Individual Individual Well ® Holding Tank ❑ Individual Water Storage ❑ Community ❑ Community Class Well ❑ Public Sewer ❑ Public Water System ❑ WaiverNariance request for: Distance: Received by: Date: US/Z?Ai COSA to be release. o the e•• -- ,unless otherwise requested by the engineer. COSA Fee $ 429 /bb Waiver Fee $ Date of Payment 5/Zft/10 Date of Payment Receipt Number d4.12130 Receipt Number COSA# O5I1$l a 3 Waiver# 414 • 5. STATEMENI4Oi SOL • ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based on procedures outlined in the Certificate of On-Site Systems Approval Guidelines for this application, shows that the on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation. Name of Firm ARCTERRA CONSULTING,INC. Phone 868-3791 Address 20441 PTARMIGAN BLVD.,EAGLE RIVER,AK 99577 Engineer's Printed Name KENNETH M. DUFFUS Date 5/25/2018 THIS COSA DOCUMENT CANNOT BE USED TO TRANSFER TITLE UNLESS ALL VENDORS(ENGINEERING,SURVEYING,CONTRACTORS,ETC...ASSOCIATED WITH THIS COSA ARE PAID IN FULL AT OR BEFORE CLOSING. Engineer's Comments: This investigation was completed in compliance with ADEC and MOA regulations. The assessment of the condition of the well and septic applies only to the conditions as of the day tested. The flow and absorption rates may change due to subsurface conditions that may not be observed from the surface, changes inland use, local soil characteristics, groundwater levels that may fluctuate during the year and the water usage of the family being served by the system. The operational life of all well and septic systems are subject to these various and dynamic characteristics and are outside the control of the evaluator of the well and septic system. Therefore, ArcTerra can not give any estimate of how long a system will function satisfactory for current or future occupants or can ArcTerra guarantee that no unseen encroachments,deficiencies or discrepancies exist. OF Az 1 <s," rte , * A 9 TT-I )\ "tea* 6. DSD SIGNATURE / ���r��- S stem#1 Approved for bedrooms. "" ` 0�J Y pp � 1,TN-1;E r a / . System#2 Approved for bedrooms. 4 c`r 1. c���� Disapproved. P%esAir Conditional approval for bedrooms, with the following stipu, t nkKil SCC . SPS Z • ••.•0/<\ ,..'' cyck0 "44P`rrc�. / Original Certificate Date: T 2 d ^1 The Municipal_ of Anchorage Development Services Division (DSD) issues Certificates of On-Site Systems Approval (COSA) based only upon the representations given in paragraph 5 by an independent professional civil engineer registered in the State of Alaska. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. 7. ATTACHMENTS: COSA Checklist X Nitrate Advisory Septic System Advisory Arsenic Advisory Well Flow Advisory Other COSA blue sheet 1°-1°-12.doc If more than 1 septic system is on the lot: COSA Checklist# of Structure served by this system , Certificate of On-Site Systems Approval Checklist Legal Description: THE VILLAGES-PINE RIDGE LOT 9 Parcel ID: 020-291-46 A. WELL DATA Well type PRVT If A, B, or C provide PWSID#_ Well Log (Y/N) Y Date completed 3/14/1996 Sanitary seal (Y/N)Y Wires properly protected (Y/N) Y Total depth 368 ft. Cased to 20 ft. (Bedrock) Casing height(above ground) 24+ in. FROM WELL LOG AT INSPECTION Date of test 311411996 5-2-2018 Static water level 17 ft. 59 ft. Well production 3 g.p.m. 1.92 g.p.m. WATER SAMPLE RESULTS: Coliform NEG colonies/100 mL Nitrate _ 1.4 mg/L Arsenic: ND ug/L Date of sample: 5/16/2018 Collected by: ARCTERRA B. SEPTIC/HOLDING TANK DATA Tank Type/Material STEP/STEEL Date installed 6/14/1996 Tank size 1250 gal. Number of Compartments 2 Cleanouts (Y/N) Y Foundation cleanout(Y/N) Y Depression over tank(Y/N) N High water alarm (Y/N) Y Date of pumping 5/2/2018 Pumper ONE STOP C. ABSORPTION FIELD DATA Date installed 5/25/2018 Soil rating (g.p.d./ft2 or ft2/bdrm) 1.2 System type SHALLOW TRENCH Length 48 ft. Width 5 ft. Gravel below pipe 2.5 ft. Total depth 5.94+ft. Eff. absorption area 375+ft2 Monitoring tube Y Depression over field N Date of adequacy test NA-NEW FIELD Results(Pass/Fail) For bedrooms Fluid depth in absorption field before test in. Water added gal. New depth in. Elapsed Time: min. Final fluid depth in. Absorption rate >= g.p.d. Any rejuvenation treatment (past 12 mo.) (Y/N &type) N If yes, give date D. LIFT STATION Date installed 6/14/1996 Size in gallons 1250 Manhole/Access (Y/N) Y "Pump on" level at 42 in. "Pump off' level at 32 in. High water alarm level at 44 in. Datum BOTTTOM OF TANK Cycles tested 2 Meets alarm&circuit requirements?Y E. SEPARATION DISTANCES WELL ON LOT TO: Septic tank/lift station on lot 100'+ On adjacent lots 100'+ Absorption field on lot 100'+ On adjacent lots 100'+ Public sewer main 75'+ Public sewer manhole/cleanout 100'+ Sewer/septic service line 25'+ Holding tank 100'+ Animal containment areas 50'+ Manure/animal excrete storage areas 100'+ SEPTIC/HOLDING TANK ON LOT TO: Building foundation 10'+ Property line 5'+ Absorption field 5'+ Water main 10'+ Water service line 10'+ Surface water 100'+ Wells on adjacent lots 100'+ ABSORPTION FIELD ON LOT TO: Property line 10'+ Building foundation 10'+ Water main 10'+ Water Service line 10'+ Surface water 100'+ Driveway, parking/vehicle storage 10'+ Curtain drain 50'+(NONE KNOWN) Wells on adjacent lots 100'+ _ F. COMMENTS G. ENGINEER'S CERTIFICATION I certify that I have determined through field inspections and review of Municipal records that the above systems are in conformance with MOA COSA guidelines in effect on this date. i OF A.6 Engineer's Printed Name KENNETH M.DUFFUS Date 5/2612018 * 4• TH Ask\ * r— Akierm, COSA canary sheet_2-6-15.doc # 1) ��� 1 -•. S., •N�` 4 N�5.26 53, t., 2606' c P (2 . / 00 I• / \, WELL ,n, J / 0 f b / W 2$• w 2s' `" ,-c / r f 4.7 N 'q7 0 u, I w � 3 0 50, -444 io � { PAVED ( �� 116, t 0/W N 722, 1 54.3 , j i , tit., tJ DECK 04 o tr. 5 EH0�SE o y4.S Ct. N6.t 54.'r. 0 9. • to 00( 4 20.5 FP CAl, O u7 O c.0 • tO ••MH ct.0 LOT 9 l 50. T \ SCREESt4C ESM C) SEPTIC • VEVT (t)p) r2 \ \ Z. O 0 • , :> O P'' I O) • l 1. 200'41ol C20A• 0' IR) •26,53' E NI 5 1 7C LOT 8 73 ANCHORAGE RECORDING DISTRICT,ALASKA ASBUILT OF: THE VILLAGES V— PINE RIDGE O =FND Sib" REBAR LOT 9 PLAT 79-255 !`"` vn SURVEY CERTIFICATE:I.John L.Schuller,Have conducted a ...."....c‘ O F A' \ yt, LAND R„. physical survey of this property as shown on this drawing and that the ,.00'Air S... '' c.,<Q�,` 4,' NC'''- T,, r improvements situated hereon are within the property lines and no _ "�' enchroachments exist other than noted.Under no circumstance should //& .• 4 9j )c .. �# '`7 6' �f Gl any information on this drawing be used for construction of fences. structures,improvements.or for establishing boundary lines. * J) y•-' 0 a' r a th �`. .� C) EXCLUSION NOTES: It is the owners responsibility to determine I the existence of any easements,covenants,or restrictions which y '.30HN L. SCHUI,LER. / = y do not appear on the recorded subdivision plat. Ira;; LS-10408 4Q',/ .r,,,,.••„`.. WORK ORDER rtuueat: DAIS s s-Lw r�;�, ' •• ���/ 1831 Talkeetna Street MAY 25, 2018 1"=30' O'p C' ”I I'.' oa i Anchorage, Alaska 99508 18-023 DRAM BY:OIEO 8Y;pdo Nuuspt BOOK/PAGE ,��Pofessionot %'`� (907) 227-1455 office JLS 3637 180145 �►����.��� (907) 274-4992 fax • MUNICIPALITY OF ANCHORAGE • / " wongeomnamoomosimmulatismasmeserma======.100..,.,.......—mm 14-A..° welopment Services Department" Phone: 9O/ 3 7904 n-Site Water&Wastewater Section Fax: 907-34 -7997 lift Station/Pump Vault Maintenance Log -Dceiric • mmer. "-ThOsnaa.±7 '12\ Sse-et Address 11011e. Legai besc. MD_ Sludge level LeTincties ,Pumping: required xel___DS2. 'Pumping completed yes..g l`g.• 6 PücnpbSketCieafldygO_Llict.441. Effluent fitter OSPed Ya§ , Coiltroi iidatS cleaned O13g2 'Proper fiatit settfts confirmed.Q. no Operation.satiStactorY Nwin System; 'Dedicated electrical alarm circuit np -Audible and visual alarm inside dwelling •Alarrn system operation _ 7:,1._+ . a atis.faCtory Manhole Riser -Ground water intrusion at.:riaer totank connection *Sig) !(ird'und water iritrusion around pipe penetrations. yeliZ) *Witep.holeltinctional .Mintiolelki: Functional (a po Insulated Propeily Secured 4:4 ri.0 PAW .Aillnaritifacturer reqsAiredinspections and rnaintenarme completed ya_n_ci 900xnetOsi: .... — ( ..... ........ .. .... ......... ........ . . ..... Mitnance *3t' - Date of t-TaiiitenarIce.a6:MaiViCompattr • • .• Signature • • :t&i Adei 4.:'.3fi;: P. 0.eigX.,..t0P5t3 AnchoVaciP,A „_ ''• • Municipality of Anchorage •• Development Services Department r; Building Safety Division On -Site Water & Wastewater Program 4700 Bragaw Street j I P.O. Box 196650 Anchorage, AK 99519-6650 www.muni.orglonsite (907) 343-7904 CERTIFICATE OF ON-SITE SYSTEMS APPROVAL ^ ��11 FOR A SINGLE FAMILY DWELLING yy �—I Parcel I.D. d,6J ' d a�' COSA# i'J 4o 139— 1. GENERAL INFORMATION Expiration Date: 9=1 !/ —07 Complete legal description Location (site address) Current Property owner(s) Mailing address Lending agency Mailing address Real Estate Agent Mailing address THE VILLAGES—PINE RIDGE, LOT 9 19100 PINE RIDGE CIRCLE * ANCHORAGE, AK 99516 RON DIKE Day phone 229-2427 19100 PINE RIDGE CIRCLE ' ANCHORAGE, AK 99516 Day phone BARBARA BOWDEN w/ PRUDENTIAL Day phone 273-7268 3801 CENTERPOINT DRIVE #200 * ANCHORAGE, AK 99503 Unless otherwise requested, COSA will be held by DSD for pickup. 2. NUMBER OF BEDROOMS: 1 3 3. TYPE OF WATER SUPPLY: TYPE OF WASTEWATER DISPOSAL: Individual Well E Individual On-site E Individual Water Storage ❑ Individual Holding tank ❑ Community Class Well ❑ Community On-site ❑ Public Water System ❑ Public Sewer ❑ The Municipality of Anchorage Development Services Department (DSD) Issues Certificates of On -Site Systems Approval (COSA) based only upon the representations given In paragraph 4 by an independent professional civil engineer registered in the State of Alaska. Certificates of On -Site Systems Approval are required for the transfer of title (except between spouses) for properties served by a single-family on-site wastewater disposal and/or water supply system. DSD also issues COSAs upon request to homeowners. Certificates of On -Site Systems Approval are valid for 90 days from the date of issue for properties served by a private or Class C well and may be reissued with new water samples. (Certificates may be reissued for a period of up to one year with valid water samples.) Certificates are valid for one year for properties served by Class A or B wells or a public water system. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineers work. 4. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based on procedures outlined in the Certiricate of On -Site Systems Approval Guidelines for this application, shows that the on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage riles and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation. Name of Firm GARNESS ENGINEERING GROUP, Ltd. Phone 337-6179 Address 3701 E. TUDOR ROAD, SUITE 101 • ANCHORAGE, AK 99507 Engineer's Printed Name JEFFREY A. GARNESS, P.E. Date Engineer's Comments: In conducting this evaluation, GEG, LtD. attempted to provide a thorough, conscientious engineering analysis of the system in accordance with ADEC and MOA DSD Guidolines 6 Regulations. The reported results described the performance of the system under the conditions encountered at the time of the lost, and separation distances measured to readily idontirtablo features. The operational life of all wells and septic systems depend on the local soils condition, groundwater levels that may fluctuate during the year, and the water usage of the family being served by the system. These conditions are outside the control ofthe evaluator of the system. Satisfactory test results do not guarantee future performance of the system, nor do they guarantee that there are no hidden defects or encroachments. GEG, LTD. can therefore not provide any warranty or future estimate of how long the system will continue to meet the operational requirements of the ADEC or MOA DSD. The content of this report is for the sole benefit of the owner listed above. Any reliance upon or use of this report by any other person or party is not authorized, nor will it confer any legal right whatsoever. S. DSD SIGNATURE ___z Approved for bedrooms. Disapproved. Conditional approval for bedrooms, with the fllowing stipulations: Attachments: COSA Checklist Septic System Advisory Well Flow Advisory Arsenic Advisory Maintenance Agreements Supplemental Engineers Reort Nitrate Advisory Other By: (Rev. 11105) • ON-SITE WATER AND WASTEWATER : PROGRAM Original Certificate Date: '6�"' / t1— 0 7 I C. ' Game s� "P4 E-79 FFG Q ao°o Pro Conditional approval for bedrooms, with the fllowing stipulations: Attachments: COSA Checklist Septic System Advisory Well Flow Advisory Arsenic Advisory Maintenance Agreements Supplemental Engineers Reort Nitrate Advisory Other By: (Rev. 11105) • ON-SITE WATER AND WASTEWATER : PROGRAM Original Certificate Date: '6�"' / t1— 0 7 Municipality of Anchorage Development Services Department Building Safety Division On -Site Water 6 Wastewater Program 4700 Bragaw Street P.O. Box 106650 Anchorage, AK 99519.6650 www.muni.orglonsite (907) 3437904 CERTIFICATE OF ON-SITE SYSTEMS APPROVAL CHECKLIST Legal Description: THE VILLAGES–PINE RIDGE, LOT 9 Parcel ID: A. WELL DATA • BEOROCK Well type PRNATE K A, B, or C provide PWSID# N/A Date completed 3/14/1996 Sanitary seal (Y/N) YES Total depth 368 ft. Cased to $20 ft. FROM WELL LOG Date of test 3/14/1996 Static water level 17 ft. Well Log (YIN) YES Wires properly protected (Y/N) YES Casing height (above ground) 12+ in. AT INSPECTION 5/2/2007 24 ft. Well production 3 g.p.m. 5.27 g.p.m. WATER SAMPLE RESULTS: ' C3' ^� Coliform 0 colonies/100 ml. Nitrate r • mg./L� `7" Other bacteria colonies/100 ml. C Arsenic: &Laug./L. Date of sample: Collected by: GEG ltd. B. SEPTIC/HOLDING TANK DATA Tank Type/Material S.T.E.P./STEEL Date installed 6/14/1996 Tank size 1250 gal. Number of Compartments 2 Cleanouts (Y/N) YES Foundation deanout (YIN) YES Depression over tank (Y/N) NO High water alarm (Y/N) YES Date of pumping 1 7 OL Pumper T Sp„p.GrS Pvl__tPf'J l7 - C. ABSORPTION FIELD DATA Date installed 0/14/1996 Soil rating OEVor ft'/bdrm) 1-2 System type TRENCH Length 44 ft. Width 5 ft. Gravel below pipe 3.5 ft. Total depth •5.13 ft. Eff. absorption area 407 W Monitoring tube YES Depression over field NO Date of adequacy test 5/2/2007 Results (Pass/Fail) PASS For 3 bedrooms Fluid depth in absorption field before test 31 In. Water added560 gal. New depth40 in. Elapsed Time: 165 min. Final fluid depth 36 in. Absorption rate >= 450+ g.p-d- Any rejuvenation treatment (past 12 mo.) (YIN & type) NONE KNOWN If yes, give date – D. UFT STATION Date installed 6/14/1996 Size in gallons 1250 Manhole/Access (YIN) YES "Pump on" level at 42 in. "Pump off" level at 32 in. High water alarm level at 44 in. Datum BOTTOM OF TANK Cycles jested 3 Meets alarm & circuit requirements? YES E. SEPARATION DISTANCES SEPARATION DISTANCES FROM WELL ON LOT TO: Septic tank/lift station on lot 100'+ On adjacent lots 100'+ Absorption field on lot 100'+ On adjacent lots 100'+ Public sewer main N/A Sewer /septic service line 25'+ Public sewer manhole/deanout N/A Holding tank N/A Animal containment areas 50'+ Manureianimal excrete storage areas 100'+ SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK ON LOT TO: Building foundation 5'+ Property line 5'+ Absorption field 5'+ Water main N/A Water service line 10'+ Surface water 100'+ Wells on adjacent lots 100 PVT & 150'+ CLASS C SEPARATION DISTANCE FROM ABSORPTION FIELD ON LOT TO: Property line 10'+ Building foundation 10'+ Water main N/A Water service line 10'+ Surface water • 105' Driveway, parking/vehicle storage 10'+ Curtain drain NONE KNOWN Wells on adjacent lots 100 PVT & 150'+ CLASS C F. COMMENTS *MEASURED 105' TO MONITORING TUBE CLOSET TO SURFACE WATER. G. ENGINEER'S CERTIFICATION I certify that I have determined through field inspections and review of Municipal records that the above systems are in conformance with MOA COSA guidelines in effect on this date. Engineer's Printed Name JEFFREY A. GARNESS Date COSA Fee S 1 JlJ . C7 D Waiver Fee E _ Date of Payment qS.11 O1()-7 Date of Payment Receipt Number t 3 Receipt Number, (R". i V06) 05-03-200T 10:49a From -PHILLIPS AK INC 9072656574 T-826 P.002/003 F-980 il•, h. oa 61 M..1.1<IuH.I ,W Co MM r.<o-e M.w..9 (u Wnq OMy1.0.1ii.1 Tin •.tC. Dy! 111=30' P79-235 THE VILLAGES - PINE RIDGE LOT 9 .0.000 SJ. �f ef- 1 1 1 1 1 1 ' w[LL W1 1 1 :1 1 • 1 1 1 \ \ 1 M 1 11 G 50. n \ 1•� o ww 1 \ .iw•,'. 1 1 °. el.lo..c \ 54Y • 1 .� T 1 \I iYt 1 fl 1 �\ 1 1 1 lw.e n+t1 1 1 • 1 � 1 1 LOT 9 \ 1 20\ 14 6 N,5.26.� I 'FKIL STRUCNRE tis -guar AS —B u I L r ..,.., .«..............»........ :V�� M..v.......... »... »....... 1 F f# "It I. ann... ..a.c. 1. t. ». r•..».nn... •. »• ..... .. 49*r ......0 «.ov uno..+u. «... .u.«•a. .0»...aet ...y,/ ..S ...e.l ...a». .»w » .» ».«.» .w.•4w •u.. 7.. ./Cw... i fit! v.0 •..........• 1« u.. ........ t., 15+0...•1 Y.N1�/11h0 ............ 0»wm. I. r»» u•» �f ^•4.. :� ..G..OLY[ ORn.0 �.0 Olfn a.. M.M• �a /1\s\\� 1.0. i I ._ ..——_•rG..L�i �r"_...�'.r-_ T:r�r.Y�1•aCoYc'�.s:S�'.s�` •�.:.-- . MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH 6 HUMAN SERVICES Division of Environmental Services an On -Site Services Section P.O. Box 19WW Anchorage, Alaska 99519-6650 343-4744 CERTIFICATE OF HEALTH AUTHORITY APPROVAL FOR A SINGLE FAMILY DWELLING Parcel I.D. # O a 0 — a '71 — y 6 HAA # _V W-- OENERAL INFORMATION Complete legal description Lot 9, ,The !ViCCagea-P.ine Ridge. Location (site address or directions) 11FIN Pine Ridge. Cu.clz Ancho•tage., AK Property owner `'i4®et 9 Ron Dihe. Day phone 562-1170 `..Mailing address P• Boz 773173 Eagle. Riven AK 99577 Lending agency ` Day phone .x Mailing address Agent Address Unless otherwise requested, HAA will be held for pickup. 2. NUMBER OF BEDROOMS: 3. TYPE OF WATER SUPPLY: Individual well Community well Public water 3 XXX Day phone NOTE: If community well system, provide written confirmation from State ADEC attest- ing to the legality and status of system. 4. TYPE OF WASTEWATER DISPOSAL: Individual on-site XXX Holding tank Community on-site Public sewer NOTE: If community wastewater system, provide written confirmation from State ADEC attesting to the legality and status of system. T2-026 (P... 1/91) Front MOA 021 S. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation of this Health Authority Approval application shows that the on-site water supply and/or wastewater disposal system Is safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is in compliance with all Municipal and State codes, ordinances, and regulations in effect on the date of this inspection. Name of Firm S a S ENGINEERING Phone 6 9 k/ - a g '7y 17034 Eeplo River Loop Road UM 204 Address Engineer's signature 71, Date /;x, 9 C ROBERT C. COWAN g CE -8801 6. DHHS SIGNATURE htrp.l'RcFzn;:� ..; Approved forbedrooms. Diss roved. Con itional pr 1 fo f1 / bedrooms, with the following stipulations: Additional Comments By: Date The Municipality of Anchorage Department of Health and Human Services (DHHS) Issues Health Authority Approval Certificates based only upon the representations given in paragraph 5 above by an independent Professional engineer registered in the State of Alaska. The DHHS does this as a courtesy to purchasers of homes and their lending institutions in order to satisfy gain federal and state requirements. Employees of DHHS do not conduct inspections or analyze data before a certificate is issued. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. 7225 01w 1A+) ft c GOA 821 e Municipality of Anchorage DEPARTMENT OF HEALTH & HUMAN SERVICES Ett Environmental Services Division 825 L Street, Room 502 • Anchorage, Alaska 99501 • (907) 343-4744 SUN 2 X96 Health Authority Approval Checklist RECEIVED p VED Legal Description: Sw19`oo�s Parcel I.D.: 0Zo-4RLG GI A. WELL DATA well type kvwrs If A, B, or C, attach ADEC letter. ADEC water system number Log present (YM) Yf s Date completed 3/ 17 9 G Total depth 3 (+ 8 Cased to 1344-1,1< a O Casing height (above ground) Sanitary seal &N) Y f S Wires properly protected (!YN) Y f 3 FROM WELL LOG AT INSPECTION Data of test 3 /9 Static water level 1 7 Well production 3 g.p.m. 91p.m. WATER SAMPLE RESULTS: Coliform Nitrate O. 10 o Other bacteria Date of sample: 6 - I7 - 9(. Collected by: S 4- S G,44.4cca l ac B. SEPTIGHOLDINGTANK DATA Date installed 6 / 14 / %, Tank size I a- S O Number of Compartments Z ' Cleanouts (9/N) Y Foundation cleanout (9M) Y Depression (YAR) 4 High water alarm �% s Data of Pumping I"/A ' N E v Pumper C. ABSORPTION FIELD DATA pro/� Date installed 6 - 14/=9 C Soil rating (g.p.d.tW or tt°/bdrm) / z System type iRe�IcW Length Width S Gravel thickness below pipe 3.5Total depth Effective absorption area 467 1� Monitoring Tube present (ON) Y Depression over field (YAC Date of adequacy test N /4 - M E w Results (Pass(Fail) Fluid depth In absorption field before test (in.); Fluid depth Peroxide 72-026 (Rev. 3/913)• (ins) Minutes months) (YM) For gal. water added (in.): Absorption rate = a.p.d. If yea, give date D. LIFT STATION Date installed C//.Y/ 4 G Size in gallons 1 7 5 0 11 Manhde/Aocess (®N) Y "Pump on" level at* 4 "Pump off" level at' 3 High water alarm level at- Y —*Datum TANK d u yr o,.., Cycles tested 3 E. SEPARATION DISTANCES SEPARATION DISTANCES FROM WELL ON LOT TO: [3,gDt11jholding tank on lot /'0'+ On adjacent lots Absorption field on lot 10014 On adjacent lots loo I+_ 1001.4 Public sewer main rJ /A Public sewer manhole/cleanout N /A Sewer/septic service line 25'+ Lift station l oo r+ SEPARATION DISTANCES FROM g9ffVHOLDING TANK ON LOTTO: Foundation to,+ Property line LSA± Absorption field 3o'± Water main/service line r 0'+ Surface water/drainage 1061+ Wells on adjacent lots SEPARATION DISTANCE FROM ABSORPTION FIELD ON LOT TO: 1001+ Property line W Building foundation 101+ Water main/service line )01+ Surface water loo'+ Driveway, parkingivehicle storage area GQ,= Curtain drain Wells on adjacent lots loo'4 F. ENGINEER'S CERTIFICATION I certify that I have determined thru Held inspec7lons and review of Municipal records in conlrnmance�ggpt idell s In effect on this date. Signature �_ � Engineers Name ed4f4 r ' C Cc✓#., Date C/ x t HAA Fee $ dD Date of Payment /2/ Receipt Number 1X 7 -7 r 6 72-026 (Rev. 3/98)" Waiver Fee $ Date of Payment Receipt Number ROBERT •C. COWAN CE -8_01 Is are