Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
STUCKAGAIN HEIGHTS #1 BLK 1 LT 1
'0 tuckagain Heights #1 Block 1 Lot i #051-021-29 Municipality of Anchorage 44., 4 . •,tom � a 1_ Development Services Department Building Safety Division AL On-Site Water and Wastewater Program,4700 Elmore Road P.O.Box 196650 Anchorage,AK 99507 Page of www.ci.anchorage.ak.us (907)343-7904 ON-SITE WASTEWATER DISPOSAL SYSTEM AND/OR WELL INSPECTION REPORT Permit Number: SW070050 PID Number: 01-021-29 Name: Robert and Delores Merchant Wastewater System: ❑✓ New ❑ Upgrade Address: 7532 Eastbrook Circle Anchorage,99504 ABSORPTION FIELD Phone: 529-4844 Number of Bedrooms:4 0 Deep Trench 14 Shallow Trench 0 Bed 0 Mound 0 Other Soil Rating: Total Depth from original grade: LEGAL DESCRIPTION 1.2 GPD/Ft2 8 Ft. Block1 Lot 1 Subdivision: Depth to pipe bottom from original grade: Gravel depth beneath pipe: Stuckagain Heights#1 4 4 Ft. Ft. Township: Range: Section Fill added above original grade: Gravel Length: 2 Ft. 50 Ft. Gravel width: Number of lines: Distance between lines: Well: ©New ❑Upgrade 5 Ft. 1 Ft. Classification(Private.A.B.C): Total Depth: Cased to: Total absorption area: Pipe Material: Private 101 Ft. 101 Ft. 500 Ft2 ASTM D3034 PVC Driller Date Dulled: Static Water Levet: Installer Date Installed: Alpine Drilling 8/6/07 42 Ft. Bob Groenway 8/20-22/2007 Yield: I Pump Set at I Casing Height Above Ground: TANK 30 GPM 90 Ft. >1.5 Ft. SEPARATION DISTANCES la septic ❑Holding 0 S.T.E.P. 0 Other: To Septic Absorption Lift Holding Public./Private Manufacturer capacity From Tank Field Station Tank Sewer Line Greer 1,250 Gal. Material: Number of Compartments: Well >100' >100' N/A N/A >25' Steel Two(2) Surface Water >100' >100' N/A N/A LIFT STATION XSize : Manufacturer Lot Line >5' 7' N/A N/A Gal. 'Pump on'level at: 'Pump off level at High water alarm at Foundation >5' >10' N/A N/A in. in. in. Pump Make&Model Electrical Inspections performed by: Curtain Drain None Noted Remarks: See Lot Line Waiver. BENCH MARK Location and Description: Garage Slab Assumed Elevation: 100.0 Ft. • Engineer's Stamp Inspections performed by: MEA Dates: 1st 8/20/207 ��oeOF'tli%I, � 2nd 8/22/2007 at*tP��........,..,QS`` Development Services Department Approval g I Gj '49 al �.�i Conditional Approval Date: 2 :,.S .... .�' O `r 4 0 0 MICHAEL E. ANDERSON •w r 0 c•• CE-4381 14'00 Reviewed and approved by: Hifi' W .644/1/ fr-j-7Date: 1I/���8 F� O ••••••• * ��r°� � p �� Municipality of Anchorage Page 2 of 3 DEVEOPMENT SERVICES DEPARTMENT 4700 South Bragaw Street Anchorage, AK. 99519-6655-343-7904 Permit Number: SW070050 79-249 PID No. 01-021-29 Z7 5p' CE5 / H / 5p ry/ cc MON —, ESS fSMT, c S �6• M1 3X21 f 3:g?3' \00N3 / Alternate Site 1 A � C4 ci N� S2�S1 0 / om Homy WE>L j ri Nei `, Four Bedro ® / ea / Nv 4 / /�� ,7 GRA,... ...... o , , z., A B / 141 h St 27.8 29.5' / S2 34.T 36.3' / ry' / C4 45.8' 48.4' C5 84.1' 95.6 / Mt 80.1' 91.1' / / J 20' UT1L ESAIT. N 89'57'35'E 397.02' STUCKAGAIN HEIGHTS, ADDN. NO. 1 LOT 1, BLOCK 1 �"1_ oF �(1,i�s,4,� 68,478 S.F. ?�'`p;. 1♦ '%y ? ' 49th * % *♦♦♦ PLAN AS—BUILT (isra.../#0.44_, MICHAEL E.ANDERSON'is •♦♦ No. CE-4381 ~ir SCALE 1' = 50' • '. Municipality of Anchorage Page 3 of 3 DEVEOPMENT SERVICES DEPARTMENT 4700 South Bragaw Street Anchorage, AK. 99519-6655 -343-7904 On-Site Wastewater Disposal System or Well Inspection Report Permit Number: SW070050 PID No. 051-021-29 I97.3 U ci) N ll II II 1 Ground UI Existin. _, 1,250 Gallon Septic Tank \ 92.9 92.75 N in— I UH U 96.2 - - / 94.2 ....* __ Finished Grade // —6n'g-in7-G ouna — ———— ✓J _ Geotextile Fabric 90.2 J Drainfield Rock 90.2 86.2 I 50'(Trench Length) i / 78.7 ✓ No Groundwater efc OF 49th %\ :'���• • ,11 ...�.1 L EA.-IL-1, PROFILE AS BUILT MICHAEL E. ANDERSON =��v�v • •���. NO. CE-4381 '�C� No Scale Ly/-U • es ' ♦♦ !,' ♦�1� �FESS ������ � ALPINE DRILLING & ENTERPRISES • Permit Number: #SW 070050 Date of Issue:.5-4-07 Parcel Identification Number: 451-021-29 Date Started: 5-6-07 Date Completed: 8-6-07 Is well located at approved permit location?® Yes E No Legal Description: Stuckaaain Fights#1 Block 1 Lot 1 Property Owner Name&Address: Robert tEDel ooresk Cn er Merchant 753e Anchorage, Alaska 99504 Borehole Data: Depth (ft) Method of Drilling® air rotary ❑ cable tool Soil Type,Thickness&Water Strata From To Casing type: steel stick-up 0 2 Wall Thickness: .025 inches gravelly silt 2 21 Diameter: 6 inches Depth: 101 feet 21 57 Liner Type: silty gravel Diameter: inches Depth: feet boulder 57 60 Casing stickup above ground: 2 feet sandy silt 60 67 Static water level (from ground level): 42 feet gravelly silt 67 91 Pumping level: 101 feet after silty water sand&gravel 91 101 2 hours pumping 30 gpm Recovery Rate: 30 gpm Method of Testing: air lift Well Intake Opening Type: [E1 Open End ❑ Open Hole ❑ Screened Start feet Stopped feet ❑ Perforations Start feet Stopped feet Grout Type: bentonite granules Volume: 2 Depth: Start 0 feet Stopped ?feet Pump: Intake Depth feet Pump size hp Brand Name Well Disinfected Upon Completion? ®Yes [] No Method of Disinfection: chlorine tablets Comments: Well Driller: Alpine Drilling & Enterprises P.O. Box 110496 Anchorage, AK 99511-0496 Attention: The well driller shall provide a well log to the property owner within 30 days of completion and the property owner or the well driller shall provide a well log to the Development Services Department within 60 days of completion. ■MJHH-24-2009 DS:7,41:1 FROM: TO:6777766 P.1/1 ■ ■ei Derolapmeet Weisel Dep.rt oot e • i■ I iali 1 Safety D)IWI' ■ ' , t On•S is Water &Wastewater Previte 4700 Owl Strait • i `' :. Ra. Mt MOO mtaapaosAlt 49!11!1650 Ali•• Ayer (+loaf i Pump 1 ns�3'Io i Log innt-Wall DAM.Perait Number. 9 Data al!um - - Paul ade>a1ffica lee Nulubt?1 Lop'DaeeiripMw lank Lt +?poly Owner Nims i AAhns ( Ifvcrea-g 9/iA lie' 46 l , / o��r -erc )a w� PIMP hoaft Detet •_1Q..•.12..7 Poop!alto Dsntb Woo llep st Wisp Outlaw tett temp Maaufeefu re Name 6 WWw lL tFO Pomp Model: tJ - �� j '-r c-$..r C 7 Pomp alas ?taw&Asper mei Dap 1 r?- feet Mew Adapter)tsa.heo rw a Nemo w 4e I/ (3~1 C.) Mew Adapter istallen 4a CO F+..1 W�Distatteted Ulu Costptstbet N Yet 0 Nit NNW of bilisteetiool_Lsc t r Commie CALL FOR SERVICE -Complete Water System Service- AAROW PUMP & WEIl SERVICE, LLC `— BRIAN WILLE ANCHORAGE EAGLE RIVER (8O7)34B. 365 (907)8224336 Attaidaat The paten insulter stall provide a pump ta■Wlaties loo to ND whitia 30 daeye of pomp iaeuleaties. 79-249 h 5p. STUCKAGAIN HEIGHTS , ADDN . NO . 1 / LOT 1 , BLOCK 1 —, s0• ry�'/r'ACCcoES 68,478 S.F. SMOEN SMT S• / 76.32 21�E 365 • 23 SEPTIC SYSTEM ni /14j N 1077. 1-47 DO . /ti / °� EXISTING BUILDING WELL / /Cij ,� /� / moi err ei / ti /, / J oO GRAVEL DRIVE // o a. / / / Ai / h / .cv // N0 / / ? / / J 20' UTIL. ESMT. N 89'57.35-E 397.02' AS — BUILT I HEREBY CERTIFY THAT I HAVE SURVEYED THE r. PROPERTY DEPICTED ABOVE AND THAT NO ♦,`lid 11.1 GASTALDI LAND ENCROACHMENTS EXIST EXCEPT AS INDICATED. ♦♦ q w• SURVEYING, LLC • of LAS • IT IS THE RESPONSIBILITY OF THE OWNER TO ♦ �F..•. . k,9 JEFF A. GASTALDI, R.L.SpETERMINE THE EXISTENCE •OF ANY EASEMENTS, 1♦�P:•.• • .* -.. j 2000 E. DOWLING RD., SUITE 8 COVENANTS OR RESTRICTIONS WHICH DO VOT '• • ANCHORAGE, ALASKA 99E 4g TH , SPEAR ON THE RECORDED SUBDIVISION PLAT. ■ • PHONE 248-5454 UNDER NO CIRCUMSTANCES SHOULD ANY DATA rY '■ GRID DATE HEREON BE USED FOR CONSTRUCTION OP FOR j . Jeff LS A. stall�'; 2043 1/4/2008 ESTABLISHING BOUNDARY OR FENCE LINES. �OAe°,�'•.. �� • �°a ANCHORAGE RECORDING DISTRICT, ALASKA �. Arofessionol P" ♦ F.B. JOB NO. *� 111111‘1111' .`, �. 1 "= 40 ' 07-08 SHS111P NOTE: NO CORNERS SET THIS DATE ANDERSON ENGINEERING P.O. BOX 240773 ANCHORAGE, AK 99524 522-7773 677-7766 (FAX) January 7, 2008 Municipality of Anchorage Development Services Department On-Site Water and Wastewater Program P.O. Box 196650 Anchorage, AK 99519-6650 Subject: Lot 1, Block 1, Stuckagain Heights Subdivision No. 1 Separation Distance Waiver Absorption Trench to Lot Line Dear On Site Services Engineer: The surveyed as-built for Lot 1, Block 1, Stuckagain Heights Subdivision No. 1 indicates the northeast corner of the absorption trench was constructed within 7' of the north lot line. Placement of the trench will not conflict with other septic systems or wells in the area. Lot 2 to the north is also a large lot and the septic area is more than 50' from the edge of this trench. In addition, the well on Lot 1 is more than 150' from the trench. We therefore recommend a waiver be issued to allow placement of the trench at 7' from the north property line. Sincerely, a4, Michael E. Anderson, P.E. WAIVER FEES: (-4 s DATE OF PAYMENT: ��`r o� .•�* ,,, A/q4. RECEIPT NUMBER: 01---1a`55 SK * \.4 SCN �i ♦�0♦C' No. CE-438' • �ar Municipality of Anchorage • • Development Services Department ►.r Building Safety Division r x On-Site Water and Wastewater Program a bV I 4700 Bragaw Street SAFETY P.O. Box 196650 Anchorage,AK 99519-6650 www.ci.anchorage.ak.us (907)343-7904 Waiver Review Worksheet WR#: 080003 PID#: 051-021-29 HA/Permit# SW070050 Date Received: January 29, 2008 Legal Description: Stuckagain Heights #1, Block 1 Lot 1 Engineer: Michael E. Anderson Anderson Engineering P.O. Box 240773 Anchorage, AK 99524 Applicant: Robert and Delores Merchant Waiver Requested: 7' lot line waiver Criteria: Geology Points: A. Water Table B. Soil Sorption C. Permeability D. Water Table Gradient E. Horizontal Separation Total: Waiver is Granted: X Waiver is not Granted: List Conditions or Reasons for above: Date: 1/29/08 By: Deb Wockenfuss Name of Reviewer Rec#: 04255 Amount: $175 Date Paid: 1/29/2008 • Municipality of Anchorage (• • . • <-••_ • P.O.Box196650•Anchorage,Alaska ,)<.h51J(�f �0•4700 Elmore Road Office:(907)343.8301 •Fax:(907)343-8200 htip://www.muni.org 61_1 IA Mayor Mark Begich Development Services Department Department January 29, 2008 Michael E. Anderson Anderson Engineering P.O. Box 240773 Anchorage,AK 99524 Subject: Waiver Request for Stuckagain Heights #1, Block 1 Lot 1 Waiver Request WR#: 080003 Parcel ID# 051-021-29 SW070050 Dear Michael E. Anderson: Your request for a waiver of the required 10 feet horizontal separation from the absorption field to the property line has been approved. The approved separation distance is 7.0 feet. This waiver approval applies to the existing absorption field to property line separation only. Any future upgrade to the on-site wastewater disposal system will require all separation distances be met or another approval from this department. If there are any further concerns or questions regarding this waiver, please call our office at 343-7904. Sincerely, Mt) 1, / Deb Wocken s Civil Engine- On-Site Water&Wastewater Program Community, Security, Prosperity 1 I El / a1 / STUCK/AN IEIOHIS/l lar a BLOCK i / / / /1/ / i ' SRICNAGAIN MOWS ' Ems W.I % / LOT 1.aDCX4 / i / / / SNICK/DAN HEIOHIS/1 z s / ile / LOT 2. / / / / ar7/r/'....*----- i ' ... • �•/ _ Ear*: / .�— • N i / N / Jt� /I / /*/ CS / 4 ....--- IX $ilo ••••••1111,1, ori / // STOCKMAN HExa1s n ' ' /• I. un Y.BLOCK 1 / /- / / -/ 2o'Wt.Nn. HILLSIDE NORfH/3 / 0 0011710t WAY l T1,and(1 I c me NORTH/b 41111144‘ ... LOT 2.araC I I Mt rout ----'-'.N.N.\\ >farout I I -•-••••**-----7// G'.° i, '�!y • • � 49th � `, % • • AREA MAP 0 • 0%1..MICHAEL E. ANDERSON ; tV V': No. CE-4381 •':,14„-% SCALE 1' = 100' ••••. '_UY t$SIU�'P� 0 1111\ TVI'' 79-249 STUCKAGAIN HEIGHTS, ADDN . NO. 1 LOT 1, BLOCK 1 117.5' 68,478 S.F. // h COMgO. NACC/ -- ESS SMT. `4'.. ta�� ` J S i 63221 E ...._12_____c 365 23 / " 50' Longx5' de Altemot x 4' Effective Depth 15 .9' \�c/ Site Absorption Trench Proposed well 124.3. 3 /O� o° ® k � ryb, .....121...___ /)IPP / /r/C4- 15 / ® G ��842 // o , �� 14 / b , ► / � Bedroom / / .(11 1,250 Gallon ome / 00 Septic Tank pR / vi PC /may ilt / h/ �/ •''4 / o rya' ,s/ / ry� / . . Jr // J 20' UTIL. ESMT. N 89'57'35"E 397.02' r 94.5' 1163.4' .����U1•% 111 .•�40 OF ki iit' 49th i' • . •' 0 � ';MICHAEL E. ANDERSON �8� j SITE LA \ •. No. CE-4381 ',�2 SCALE 1" = 50' NIESS1����•• MUNICIPALITY OF ANCHORAGE Development Services Department Onsite Water 6 Wastewater Program 4700 South Bragaw Street P.O. Box 196650, Anchorage, AK 995196650 (907) 343-7904 ON-SITE WASTEWATER DISPOSAL SYSTEM / WATER SUPPLY PERMIT Initial Date Issued: May 04, 2007 Expiration Date: May 03, 2008 Permit Number: SW070050 Parcel ID: 051-021-29 Legal Description: STUCKAGAIN HEIGHTS #1 BLOCK 1 LOT 1 Design Engineer: 0014 ANDERSON ENGINEERING Site Address: NHN BASHER DRIVE Owner Name: ROBERT & DELORES MERCHANT Owner Address: 7532 EASTBROOK CIRCLE ANCHORAGE. AK 99504 - Lot Size: 68478 SO. FT. Total Bedrooms: 4 Permit Bedrooms: 4 This permit is for the construction of: ❑✓ Disposal Field ❑✓ Septic Tank ❑ Holding Tank ❑ Privy ❑✓ Private Well ❑ Water Storage All construction must be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal Code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations ( 18AAC72 ) and Drinking Water Regulations ( 18AAC80 ). 3. The engineer must notify DSD at least 2 hours prior to each inspection. Provide notification by calling (907) 343-7904 (24 hours). ( Not required for a Water Supply Permit only). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must be either: A. Open and closed on the same day. B. Covered, seated, and heated to prevent freezing. Received Y Date: Issued By. 1 1 �I Date: Sblo_ Municipality of Anchorage Development Services Department Building Safety Division Onsite Water and Wastewater Program 4700 Bragaw Street P.O. Box 196650 Anchorage, Alaska 9951 9-66 50 www.muni.org/onsite (907) 343-7904 ON-SITE SEWER/WELL PERMIT APPLICATION FOR A SINGLE FAMILY DWELLING Parcel I.D. 041-021-29 Property owner(5) Robert & Delores Merchant Day phone 529.4844 Mailing address 7532 Easthrook Circle Anchorage, AK Zip Code Site address N P&I Basher Drive Zip Code 99504 Legal description (Sub'd., Block & Lot) _Lot 1, Block 1, Stuckagain Heights Subdivision, Addn. No. 1 Legal description (Township, Range & Section) Lot Size 68,478 Sq. Ft. Number of Bedrooms Four (4) THIS APPLICATION IS FOR (® all that apply): Absorption Feld 0 Septic Tank 0 Holding Tank El Privy Private Well 0 Water Storage 1■1 THIS APPLICATION IS AN: Initial El Upgrade El Renewal El certify that the above information is correct. I further certify that this application is being made for a Single Family Dwelling and is in accordance with applicable Municipal Codes. (Signature of property owner or authorized agent) Permit/Rush Fees: LEU F ( tT� Waiver Fees: Date of Payment: //B IUI Date of Payment: Receipt Number. —1 Zol Receipt Number. (Rev. 11105) ANDERSON ENGINEERING P.O. BOX 240773 ANCHORAGE, AK 99524 522-7773 677-7766 FAX April 30, 2007 Municipality of Anchorage Development Services Department On -Site Water and Wastewater Program 4700 South Bragaw Street Anchorage, AK 99519-6650 Subject: Lot 1, Block 1, Stuckagain Heights Subdivision, Addition No. 1 Septic System Design and Permit Application Impacts to Adjacent Properties Dear Onsite Services Engineer. The owner of Lot 1, Block 1, Stuckagain Heights Subdivision, Addition No. 1 intends to construct a new four-bedroom home on the lot. We are therefore requesting a permit be issued for the construction of a new well and septic system to accommodate the home. The attached Site Plan and backup documentation identify the location and configuration of the proposed well and septic system along with the alternate site. Also identified on the plans are the existing wells and septic systems on surrounding lots. No conflicts exist between the proposed well and septic system and wells or septic systems on adjacent lots. Drainage arrows are shown on the site plan showing the grade and direction of flow on the lot. The drainage pattern will not be changed as a result of this project. The test holes were placed on the lot in the area of the absorption trench and alternate site in 2003 by Alaska Water and Wastewater Consultants, Inc. The logs indicate clean poorly graded sandy gravel (GP) underlain by poorly graded sand The percolation rate of the soil was determined to be less than 5 minutes per inch. Sufficient sand is in the soil to filter the effluent. No filter is required. No groundwater was found during the placement of the test hole and none was noted during the monitoring period. An application rate of 1.2 gallons per day per square foot was used in the design of the absorption system. We are proposing to place a new 1,250 -gallon septic tank and a 50' long by 5' wide by 4' effective depth absorption trench to treat and dispose of the effluent generated in the house. The elevation of the distribution line in the absorption trench will be 4' below the surface and the total depth will be 8'. A minimum of T of fill or 2' of insulation and 2' of fill will be placed over the absorption trench and 4' over the septic tank. Lot 1, Block 1, Stuckagain Heights Subdivision No.1 April 30, 2007 Page Two The ground surface on the lot in the area of the septic system slopes to the southwest. The new trench will be constructed parallel with the slope as much as possible in conformance with Municipal requirements. The new septic system will be constructed a minimum of 100' from all wells and any surface water and 10' the proposed and existing water services in the area. If the system is constructed in accordance with our design the following statements apply: The system, if constructed as designed, will have no adverse impact on the wells in the area or those to be constructed in the future. 2. The system, if constructed as designed, will have no adverse impact on existing septic systems in the area or those to be constructed in the future. 3. The system, if constructed as designed, will have no adverse impact on reserve space, either surface or subsurface, on any lots located in the area. 4. The system, if constructed as designed, will have no adverse impact on drainage patterns in the area. The current drainage pattern will be maintained. Sincerely, Michael E. Anderson, P.E. Attachments V C�AEL E. A\9E4$CV 1 SI / SI a.1 / a.1 / SRICNAONI MONTS/1 LOT 3.BLOCK 1 i / j 1 / / / / / / i / SRICKAGMN HMOS / p�M TIS i LOT 1.BLOCK 4 / ( , / STUCK/GAIN BLOTS/1 / LAT 2.BLOCK 1 / / / � i / / 7.....****---. O0'Abr i / 151.67 VI" / .....78.7 .M.-- i \NN''''\ ii / ....... .3:11/ ..' r / i , i s 1 / % , STOCKMAN MONTS#2 / 1011 Cr• tia* ..10"--* / • / _, 4 / ---4J -T�e mar HIIL�E NORM/3 LOT 1.BLOCK 1 HI11510E NORTH/S 4111444 LOT 2.BLOCK 1 1 IM0t >1b'Spee SaAh I ..7v.„ _,......,�_, :r9�i J. ' I. .. •� 49th i• • AREA MAP .. • ,MICHAEL E. ANDERSON i f: I.ff". NO. CE-4381 s SCALE 1' = 100' 4li11l....lhs 79-249 STUCKAGAIN HEIGHTS, ADDN . NO. 1 LOT 1 , BLOCK 1 117.5' 68,478 S.F. / / 5 47 COMM0' / `�ACCS'S E ry4tir ) �a� __J S 63221 f 365.23. / ts.� " 50' Long x 5' Wide Altemat x 4' Effective Depth 15..9' ��C/ Site Absorption Trench Proposed Wee 124.3' / oons aB x poxQ 0' ® /a30 /).':.41 "4/ / , G ��p042 / / illP/ o E�• / N Bedroom / / = 1,250 Gallon ome / o0 al Septic Tank c / h• . pG . , ,' '.f /: e1/4/ 1 iio ta✓ / N, x / .. 's?. / J 20' UTIL. ESMT. N 89'57'35"E 397.02' 94.5' 163.4' ��*11111‘11%:1Z4);........4 � :57.7 49th ''*♦AV �. ;MICHAEL E. ANDERSON : SITE P �A \ •v,•. No. CE-4381 tiN SCALE 1" = 50' �•PRE/F'ESSISfi••� LOT 1, BLOCK 1, STUCKAGAIN HEIGHTS SUBDIVISION, ADDITION NO. 1 DESIGN FACTORS: SYSTEM REQUIREMENTS: Four Bedroom Home Perc. Rate: <1 Min./Inch Application Rate: 1.2 GPD/SF 5' Wide Trench System 1,250 Gallon Septic Tank 4' Drainfield Rock 4 Bedrooms X 150 GPD/1.2 GPD/SF (Application Rate) = 500 SF Absorption Area 500 SF/5 SF/LF•.5 (Red. Factor) = 50 LF Trench Length THEREFORE: Construct a 50' Long x 5' Wide x 4' Effective Depth Absorption Trench at the Location Shown. Flow Line Elevation in Trench to be 4' Below Original Ground Surface. Total Depth to be 8' Below Existing Ground. Provide 4' Cover Over Septic Tank and 3' Cover Over Absorption Trench. Maintain 100' Separation from Wells in the Area. Natural Backfill Geotextile 3-6"—ICU Jc 6" O 4"P erforated PVC (Holes Dawn) 4'0" 5' Drainfield Rock TYPICAL 5' WIDE TRENCH SECTION ,.......� (NO SCALE) •���p(E OF A4-1 NOTE: Grade Area Over Trench to Drain Away.,.''* Minimum 6' Separation From Bedrock. '_...{„„ 4 .„ Minimum 4' Separation From Groundwater. �_..—....... Minimum 100' Separation From Wells in the Area. .R f MMJMEIE W0ERe0 Minimum 100' Separation From Surface Water or Streams. airy%+ No. e I 0 GROUNDWATER ooaoo p •, . oe OF pp4 11/04/03 NO H2O �s ALASKA WATER &; WASTEWATER H .7 CONSULT T NC. 4 .: ... .. ...........:.°,O • • • • 7� /.2!.: O 5101 CT1 DOR ROAD. SWE 101 MICM AK 09507 90 13 i1 9 AIC W -3346 SII 8 SOIL LOG — PERCOLATION TEST r A. Gor ess. O LEGAL DESCRIPTION: STUCKAGAIN HEIGHTS ADDITION #1; BLOCK 1, LOT 1 0 A OQQ� PERFORMED FOR: 7953 •' `FOTO SANDRA FREDERICK DATE: 11/04/03 DEPTH_ �e^eoP o(aesio�°���� Opp4Oood000 (feet) __=_ ORGANICS TEST HOLE 1 SOIL CLASSIFICATIONS • 2 OR GW G 7t w GM CL GC OL TH/z im lkT SW MH + TH/1 SP CH + :. GP OH ' Sc 6 ::.> :; 12Z 7 1✓ DEPTH TO DATE 8 SITE PLAN 1•-100' 11 ,*: oes loom :••• .•.. s12— o. ., 13 •; ,"s " ' SP ;, 14—.... .: ; .• :::: 15 •:•• ' B.O.H. 16 17 ,8 PERCOLATION RATE <1 (MIN./INCH) PERC. HOLE DIA. 6 (INCHES) 19 TEST RUN BETWEEN 5 FT. AND 6 FT. ZO A FOUR HOUR PRESOAK WAS PERFORMED: ❑ YES ENO SOILS LOGGED BY: CARLA JEAN SMITH PERCOLATION TEST PERFORMED BY: CARLA JEAN SMITH COMMENTS: NO WATER FOUND IN TEST HOLE PERFORMED BY AKWWC, INC. I, JEFFREY A. GARNESS,. CERTIFY THAT THIS ERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE: ///18/0? GROUNDWATER NO H2O 11/04/03 NO H2O 11/11/03 ��®aaaa 2 .�� "---..4 .'sip, ALASKA WATER & WASTEWATER o QQ, CONSULTANTS, INC. Jg' .. / .. O0 3701 E. TUDOR ROAD. SUITE 101 • ANCHORAGE, AK 99507 • PHONE: (907)337-6179 • FAX: (907)338-3246 • WEBSITE: akwwc.com 0 I I D ,SOIL LOG — PERCOLATION TEST O •.L. ..1/ v LEGAL DESCRIPTION: STUCKAGAIN HEIGHTS ADDITION #1; BLOCK 1, LOT 1 �On •.Je i EI•;•,• ess. e`, $ PERFORMED FOR: SANDRA FREDERICK DATE: 1 1/04/03 Q4,,i ••• It •- ••,c�O DEPTH �44Qap ....• no\foo feet - ORGANICS ��04ro 0000Q (feet) • TEST HOLE #2 •••• .• SOIL CLASSIFICATIONS ,� i••••••. d,••,o: GW •_ ORG :Yee. SP GM j/14 CL 4 ••i•'i•. GC 1 III OL TH#2 ••:i•••. (;)0P0V SW J MH ♦ TH#1 I •••••l ,•• 's P J CH •••6•10. • SM .� OH .•,i�,• �� SC w DEPTH TO 7— GP GROUNDWATER DATE _...__..._____ 8 .:•.,� . NO H2O 11/04/03 _-.... S,,.?•. NO H20 11/11/03 9—••• ••••• SITE PLAN •▪••r••i l''=100' 10- i,•41, ••••••• CLOCK NET TIME WATER LEVEL NET DROP 11 -4:5;:;: SP DATE READING TIME (MINUTES) READING (INCHES) '*••.'• 11/07/03 1 - - 6" 12-a•••,•i s•i••••. 2 - 1.8 0" 6" 41.4040.0 13- 11:t.:' 3 - - 6" - .•,s,,• 0" 6" 14 *******6` 5 — — 6" — B.O.H. ---- — 6 — 2.0 0" 6" 15- 16- -_. ............ -- 17- _- ._._...._......................__.. - -- - - 18- PERCOLATION RATE <1 (MIN./INCH) PERC. HOLE DIA. 6 (INCHES) 19- TEST RUN BETWEEN 5 FT. AND 6 FT. 20 A FOUR HOUR PRESOAK WAS PERFORMED: ❑ YES U NO SOILS LOGGED BY: CARLA JEAN SMITH PERCOLATION TEST PERFORMED BY: CARLA JEAN SMITH COMMENTS: NO WATER FOUND IN TEST HOLE PERFORMED BY AKWWC, INC. I, JEFFREY A. GARNESS, CERTIFY THAT THIS W S P RFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE: /t / 6/0_?� MUNICIPALITY OF ANCHORAGE .4,6101 nivirii,' DEVELOPMENT SERVICES DEPARTMENT •���P� •..., •44. 4700 ELMORE DRIVE ANCHORAGE, AK 99519-6650 ? \ 49th " SOILS LOG - PERCOLATION TEST 11444-1-•1. c W.MICHAEL E. ANDERSON ai= LEGAL DESCRIPTION: LOT I, BLOCK I, STUCKAGAIN HEIGHTS SUBDIVISION N04,f '••••• °' CE=4381 :'��,��• PERFORMED FOR: ROBERT MERCHANT •��1 Va�..... �:as DATE: 6/5/2007 PROJECT No.: Ni ��� ��• PARCEL ID#: TECHNICIAN: A. HARALA Professional Engineers Stamp: DEPTH TEST HOLE 3 (feet) 1 V// OB/OG SLOPE SITE PLAN OL 2 WELL LGRADED GRAVEL 3 4 5 SEE SITE PLAN 6 GW/GP 7 SOME SILT 8 9 10- WAS GROUND WATER ENCOUNTERED? NO IF YES @ WHAT DEPTH'? DEPTH OF WATER AFTER MONITORING: 11 DATE OF MONITORING: 12 SAND WITH SILT SP/SM GROSS TIME NET TIME DEPTH TO NET DROP 13 DATE READING (MINUTES) (MINUTES) WATER (INCHES) (INCHES) 14 BOH 15 16 17 18 19 20 PERCOLATION RATE: (MIN/INCH) PERC. HOLE DIA. (INCHES) TEST RUN BETWEEN: FT. and FT. COMMENTS: MATERIAL IN TEST HOLE IS IDENTICAL TO TEST HOLE NOS. I AND 2 AS COMPLETED BY AWWC. No PERC. TEST COMPLETED. ESTIMATED AT < 5 MIN./INCH. TEST PERFORMED BY ANDERSON ENGINEERING. I, MICHAEL E. ANDERSON CERTIFY THAT THIS WAS PERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPLE GUIDELINES IN EFFECT ON THIS DATE: 1/5/2007