HomeMy WebLinkAboutKRISTAS LT 127BKrl*stas Lot 1276 #051-144-58 mspecvon Kepon_i-T-iz.coc Municipality of Anchorage Community Development Department Page 1 of 3 On-Site Water and Wastewater Program 4700 Elmore St. • P.O. Box 196650 Anchorage, AK 99519-6650 • http://www.muni.org/onsite • (907) 343-7904 ON-SITE WASTEWATER INSPECTION REPORT Permit Number: OSP121019 PID Number: 051-144-58 ❑ Z New El Upgrade Name: Troy Davis Homes, Inc. ABSORPTION FIELD ❑✓ Deep Trench ❑ Shallow Trench ❑ Bed ❑ Mound Address 165 E. Parks Highway, Wasilla, AK 99654 ❑ Other Phone Number of Bedrooms Soil Rating Total depth from original grade 357-9394 3 6GPD/SF 9.7 Ft. LEGAL DESCRIPTION Depth to pipe invert from original grade 3.7 Ft. Gravel depth beneath pipe 6.OFt. Subdivision Block Lot Kristas 127B Fill added above original grade 0-2 FL Gravel length 64.0 Ft. Township Range Section Gravel width 3.01Ft, Beds: Number of Lines Distance between lines I Ft. SEPARATION DISTANCES To Septic Absorption Holding Sewer Total absorption area Number of trenches Dist. between trenches From Tank Field Lift Station Tank Line 768 Ft 2 > 12 Ft. Well >100' >100' N/A N/A >25' TANK Septic ❑ S.T.E.P. ❑ Holding ❑ Other Manufacturer Anchorage Tank Capacity I 1,OOOGal. Surface Water >100' >100' N/A N/A Material Number of compartments Lot Line >5' ><10' N/A N/A Steel Two (2) NA Foundation >5' >10' N/A N/A LIFT STATION Manufacturer Capacity Curtain Drain None Noted Gal. Remarks Pump on level at in. Pump off level at in. High water alarm at I in. Pump make and model Electrical Inspections performed by Installer PIPEMATERIAL Housetotank D3034 Tankto D3034 draintiield Pomraning Excavation Drainfield F810 CO/MT D3034 Inspector M. Anderson BENCH MARK (Assumed elevation) 100.Oft Inspection„ dates: 1 3/16/12 2°d 3/17/12 Location and description 3' 4th Garage Slab COMMUNITY DEVELOPMENT DEPARTMENT APPROVAL Conditional Approval: Date S•p���d...A4 gst�e ���;'., •.,/� e 49m • **i .................................. /Re•AUCHAR & ANDIMMONS �r CE -1381 :$vAW •o�1��••� Approved Date 6-z-1 y mspecvon Kepon_i-T-iz.coc Municipality of Anchorage DEVEOPMENT SERVICES DEPARTMENT Permit Number: OSP121019 4700 Elmore Road Anchorage, AK. 99519-6655 - 343-7904 126A 589'46'03"W 150.0 127A 0 J U N rq N m SI A J 82 M1 ALTERNATE SITE Advantex Treatment System with a 15' x 20' Absorption Bed. EXISTING HOUSE 15' B.L.M. EASEMENT 150.0 WELL m s TARIKA AVENUE s PLAN AS -BUILT SCALE V = 40' Page 2 of 3 PID NO.: 051-144-58 125A 128A Municipality of Anchorage Page 3 of 3 DEVEOPMENT SERVICES DEPARTMENT 4700 Elmore Road Anchorage, AK. 99519-6655 - 343-7904 On -Site Wastewater Disposal System or Well Inspection Report Permit Number: OSP121019 PID No. 051-144-58 00.7 N Ul U F U No Groundwater 3/6/12 NORTHWEST TRENCH U F U SOUTHEAST TRENCH E3 PROFILE AS -BUILT MICHAEL No.E, ANDERSON CE -4381 No Scale 3.0 X1.7 257 SUWVAN 'WATER MfELLS r namesfie_Gamreeretal-Seolhsrmal l _. Phone h@rfia62r58 _ _ .. armrnnianemwlerwefb.c>•,n � Well Log Permit Number: OSP 121019 DateO Issue 2/2772912 Parcel identification Number: 051444sa000 Date Started: 3114/2012 Date Completed: 3f1512t112 Is well Iocated at approved pemtitlocation? IX jYes Property Description KRISTAS Lot 1270 Block NONE Section: Town: Range: property Owner Name & Address: TROY DAVIS HOMES 165 E. PARKS HWY. #2940 WASg_LA, AK 99654 Water Sample Resuhs: Arsenic.�.- Depth Method of Drilling L] air rotary cable tool Borehole Data: Cole Sullivan Nitratesmg(i Soil Type, Thickness& Water Strata From To Casing type: Otherbacteria: 6 2 Wall thickness o2s.__._inches Casing Stickup a Diameter 6 inches Total: 74 Teet Fill 2 -- Liner type: - Overburden 4 6 Diameter inches Depth: feet Si@Sand Gravel 6 22 Casing stick-up above ground: 2 feet Static Water Level{from top of casing} Pt3. feet Sgt Sand Gravel W/Ctay 22 26 Silt Sand Gravel Dense 26 35 pumping Level:. feet after .. 1 hours pumping gpm S6t8SarM WlGravel 35 38 _.. - --- —... P"overy Rate I %- gpm Sift It Sand a6 Methal of Testing: Air Hardpan 50 74 Well Intake Opening Type Gray & White Bedrock .. 74 at 4--J Open had IXJ Open Hole Gray Bedrock Hard 81 135 {-� Screened Start: feet Stopped feet 135 138 perforations Start feet Stopped feet Gray & White Bedrock Grout Type: Boubmite dry granular Volume: Pounds Gray Bedrock 138 164 Depot 44 starto feet Slapped _ 44 feet Gray & Wtine Bedrock 164 168 Pump intake Depth: feet Gray Bedrock 168 272 _—....... Pump size: _ -.._ HP brand name .... While Bedrock 272 273 Well disinfected upon Completion? Gray Bedrock 273 286 Method of disinfection CHLORINE 50 PPM Comments: Meal on top of bedrock was damp. Casing left slightly above bedrock so that it might seep in. Water Sample Resuhs: Arsenic.�.- Well Driller: Cole Sullivan Nitratesmg(i Sullivan Water wells Total Coliform Bacteria —.—. colonies/100ml, _col/100mL P.O. Box 670272 Chugmk, AK 99567 Otherbacteria: I907i 698-2759 Attention: The property owner shalt provide this log to DSD {onsite} and DNR within 30 days of completion- 12r7A LOT 127D HAS 44.262 S9.FT. OF AREA 126A 1 25A° ° ° IORBES ° 0 0 d p D O P 4 TARIKA AVENUE 128A 'FOR: TROY DAVIS DOMESUate 1" !le Legal Descri ]=30' B Block Grid -17-12 Lot 127 As -built NW 1258 2120102 KRISTA'S Forbes &AssfxiaYeS 1/u'. P.O. Box 232293 Anchorage, Maalm 99523 Drawn by Field Book SUBDIVISION (907) 22T-fi681 cef 240 1 hereby certify that the property described hereon has been surveyed by me o at my direction, and that the improvements ther ((/*/�� � Q�+.'4+4 1p0 situated are Within the lines and do not overlap or encroach on the n{{ �4 8r9perty property tying dJ ent therelc unless otherwise shown. That no +•+-r { Improvements on the property lying adjacent thereto encroach on the ,px: 49 Te .9 { premises ther question and [ Cher a no roadways. transmission �•• + t other linea or easements osaid property except a shown. + •+ ••.....„. ... It is the responsibility of the owner or builder, prior to oonstruetton, x I : ¢ ,{S it inverify proposed building grade relative to finish grade and utility % S�FORRGS :• coeeons and to determ the e ae x existence of any ment ¢a..—name nLvAed { n+, orreb me subdivision iens which do not appear on the recorded plat. { •.7-17-12� �Sa+ dlafancmeyrease ojer scaling ,{+��pt�'+Siil06�v_1�+ Re duction Development services DepartmenT Building Safety Division On-Site Water & Wastewater Program r w 777, 4700 Elmore Road U P.O. Box 196650 Mark Begkh Anchorage, AK 99507 e A Mayor www.mun_ i.00r /onsite (907)343-7904 Pump Installation Log crop ID101CI Well Drilling Permit Number: SW Date of Issue: T3� � l Parcel Identification Numbers„ A I'-1145a)(X�3 Legal Description Property Owner Name & Address: KP-1i-as, _T" Dl-:Nis fivy_e Pump Installation Date: O ( ou I I � Pump Intake Depth Below Top of Well Casing. a.�Jeet Pump Manufacturer's Name: Ctx�iclS Pump Model: Pump Size 3/4 hp Pidess Adapter Burial Depth: feet Pidess Adapter Manufacturer's Name: ("Cl �1t1"�Gl Pidess Adapter Installer. pory-)f;xa l t � Well Disinfected Upon Completion? [Ries ❑ No Method of Disinfection: 0Y,)lo2inc_ ec IRAN► Comments: Pump Installer Name: cotes �t.,�i Ilvo_n Ei ct)c�► CR_OE�S Sul li vo -0 U3CL-_ e r U.�e_e_ S Attention: The pump installer shall provide a pump installation log to the DSD within 30 days of pump installation. On -Site Water & Wastewater System Permit MUNICIPALITY OF ANCHORAGE Development Services Department On -Site Water & Wastewater Program 4700 Elmore Road, PO Box 196650 Anchorage, AK 99519-6650 Telephone: (907) 343-7904 Permit Number: OSP121019 Tax Code Number: 05114458000 Work Type: WellSeptic Renewal Permit Effective Dates: February 27, 2012 to February 26, 2013 Design Engineer: ANDERSON ENGINEERING Subdivision: KRISTAS Site Legal Address: KRISTAS LT 127B G:1258 Owner/Address: MASON GARY & AUDREY JOINT 'S'-/(0-iZ o%.aa REVOCABLE TRUST MASON G L & A G/TRUSTEES 18540 UPPER MC CRARY RD EAGLE RIVER AK 9E Site Mailing Address: Lot Size in Sq Ft: 44262 Total Bedrooms: 3 This permit is for the construction of: Y Disposal Field Y Septic Tank N Holding Tank N Privy Y Private Well N Water Storage All construction must be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80). 3. The wastewater code requires inspections during the installation. The engineer must notify the Development Services Department at least 2 hours prior to each inspection. Provide notification by calling (907) 343-7904 (24 hours). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must either: A. Open and Close on the same day. B. Covered, sealed, and heated to prevent freezing. Received Issued By e01- McVZ_ces 4-kt- tnrelt JoCo,�:an. MUNICIPALITY Community Development Department ! Phone: 947-343-7904 Development Services Division Fax: 907-343-7997 Cin -Site Water & Wastewater Program Mayor Dan Sullivan ON-SITE SEWER/WELL PERMIT APPLICATION FOR A SINGLE FAMILY DWELLING 9==INDIK11755E IM -1 Property owner(s): Troy Davis Homes, Inc. Day phone: 357-9394 Mailing address: 165 E. Parks Highway, Wasilla, AK 99654 Site address: Tarika Avenue Legal description (Sub'd., Block & Lot): Kristas Subdivision, Lot 127B Legal description (Township, Range & Section) Lot Size: 44,262 Sq. Ft. Number of Bedrooms: Three (3) THIS APPLICATION IS FOR: THIS APPLICATION IS AN: (® all that apply) Initial ❑ Absorption Field X Upgrade ElSeptic Tank X Holding Tank ❑ Renewal X Privy ❑ Private Well X Water Storage ❑ THIS APPLICATION INCLUDES A VARIANCE / WAIVER REQUEST FOR: I certify that the above information is correct. I further certify that this application is being made for a Single Family Dwelling and is in accordance with applicable Municipal Codes. owner or authorized 14 Waiver Fees: '}aI �a Date of Payment: 09t Receipt Number: :) [ oa (UR Waiver No. C:\Users\Ben\Desktop\Permit Application Lot 127B.docC:\Users\Ben\Desktop\Permit Application Lot 127B.doc Permit/Rush Fees: Date of Payment: _ Receipt Number: 01 Permit No. 8i 14 Waiver Fees: '}aI �a Date of Payment: 09t Receipt Number: :) [ oa (UR Waiver No. C:\Users\Ben\Desktop\Permit Application Lot 127B.docC:\Users\Ben\Desktop\Permit Application Lot 127B.doc ANDERSON ENGINEERING P.O. BOX 240773 ANCHORAGE, AK 99524 522-7773 677-7766 (FAX) February 22, 2012 Municipality of Anchorage Development Services Department On -Site Water and Wastewater Program 4700 South Bragaw Street Anchorage, AK 99519-6650 Subject: Lot 127B, Kristas Subdivision Septic System Design and Permit Application Impacts to Adjacent Properties Dear Onsite Services Engineer: The owner of Lot 1276, Kristas Subdivision intends to construct a new three-bedroom home on the lot. A permit for a new well and septic system was originally issued on this lot in 2007. We are therefore requesting the permit be reissued for the construction of a new well and septic system in the same location to accommodate the home. The attached Site Plan and backup documentation identify the location and configuration of the proposed well and septic system along with the alternate site. No existing wells or septic systems are closer than 100' from the proposed septic system. Wells on the adjacent lots are shown on the Site Plan. Drainage arrows are shown on the site plan showing the grade and direction of flow on the lot. The drainage pattern will not be changed as a result of this project. - The test holes placed on the lot and utilized in the 2007 permit in the area of the absorption trench and alternate site indicated silty gravel (GM) material with some silt. The percolation rate of the soil at the primary site was determined to be from 23 minutes per inch. No groundwater was found during the placement of the test hole and none was noted during the monitoring period. An application rate of .6 gallons per day per square foot was used in the design of the absorption system. We are proposing to place a new 1,000 -gallon septic tank and 2-32' long by 3' wide by 6' effective depth absorption trenches to treat and dispose of the effluent generated in the house. The elevation of the distribution line in the absorption trench will be 3.5' below the surface and the total depth will be 9.5'. The alternate site will be near Test Hole No. 2 and consist of an Advantex Treatment System with a 15' wide by 20' long absorption bed. The bottom of the bed will be 4' below the surface. A minimum of 3' of fill or 2" of insulation and 2' of fill will be placed over the absorption trench and 4' over the septic tank. Lot 1278, Kristas Subdivision February 22, 2012 Page Two The ground surface on the lot in the area of the absorption trenches slopes to the southeast at a grade of 10%. The new trenches will be constructed parallel with the slope as much as possible in conformance with Municipal requirements. The new septic system will be constructed a minimum of 100' from all wells and any surface water and 10' from the proposed and existing water services in the area. If the system is constructed in accordance with our design the following statements apply: 1. The system, if constructed as designed, will have no adverse impact on the wells in the area or those to be constructed in the future. 2. The system, if constructed as designed, will have no adverse impact on existing septic systems in the area or those to be constructed in the future. 3. The system, if constructed as designed, will have no adverse impact on reserve space, either surface or subsurface, on any lots located in the area. 4. The system, if constructed as designed, will have no adverse impact on drainage patterns in the area. The current drainage pattern will be maintained. Sincerely, lk OF �Cgsr�` Ben am J. Schiller, P. E. . Attachments i �. 491-H '-------- ................... al iin 1 Schiller; CE -12592 ahah� -.• ��. LOT 127B, KRISTAS SUBDIVISION DESIGN FACTORS: SYSTEM REQUIREMENTS: Three Bedroom Home Deep Trench System Perc. Rate: 22.8 Min./Inch 1,000 Gallon Septic Tank Application Rate: .6 GPD/SF 6' Drainfield Rock 3 Bedrooms X 150 GPD/.6 GPD/SF (Application Rate) = 750 SF Absorption Area 750 SF/12 SF/LF = 62.5 LF Trench Length THEREFORE: Construct 2-32' Long x 3' Wide x 6' Effective Depth Aborption Trench at the Location Shown. Flow Line Elevation in Trench to be 3.5' Below Original Ground Surface. Total Depth to be 9.5' Below Existing Ground. Provide 3' of Cover Over Trench and 4' Over Tank or Provide 2" of Insulation and 2' of Cover. Provide Flow Splitter Valve to Insure Even Flow to Each Trench. Natural Backfill 3'0" Geotextile Fabric g" 4" Perforated PVC (Holes Down) [4611 3' Drainfield Rock TYPICAL DEEP TRENCH SECTION (NO SCALE) NOTE: Grade Area Over Trench to Drain Away. Minimum 6' Separation From Bedrock. Minimum 4' Separation From Groundwater. Minimum 100' Separation From Private Wells in the Area. Minimum 100' Separation From Surface Water or Streams. Minimum 10' Separation From Water Service Line. MUNICIPALITY OF ANCHORA GE Development Services Department On -Site Water Q Wastewater Program 4700 South Bragaw Street P.O. Box 196650, Anchorage, AK 99519-6650 (907) 343-7904 ON-SITE WASTEWATER DISPOSAL SYSTEM I WATER SUPPLY PERMIT Initial Permit Number: SW070066 Legal Description: KRISTAS LOT 127B Date Issued: May 17, 2007 Expiration Date: May 16, 2008 Parcel ID: 051-144-58 Design Engineer: 0069 DOUGLAS T. KENLEY Site Address: NHN TARIKA AVE Owner Name: GARY & AUDREY MASON Lot Size: 44262 SO. FT. Owner Address: 18540 UPPER MCCRARY ROAD Total Bedrooms: 3 Permit Bedrooms: 3 EAGLE RIVER, AK 99577 - This permit is for the construction of: Q Disposal Field ❑✓ Septic Tank ❑ Holding Tank ❑ Privy ❑✓ Private Well ❑ Water Storage All construction must be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal Code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72 ) and Drinking Water Regulations ( 18AAC80 ). 3. The engineer must notify DSD at least 2 hours prior to each inspection. Provide notification by calling (907) 343-7904 (24 hours). ( Not required for a Water Supply Permit only). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must be either: A. Open and closed on the same day. B. Covered, sealed, and heated to prevent freezing. Received Date: �'l 7 Issued By: _(h_j Date: S 17 /01 AZunicipality of Anchorage Development Services Department Building Safety Division / On -Site Water and Wastewater Program 4700 Bragaw Street P.O. Box 196650 Anchorage, AK 99519-6650 www.muni.org/onsite (907) 343-7904 ON-SITE SEPTICMELL PERMIT APPLICATION FOR A SINGLE FAMILY DWELLING Parcel I.D. 051- 114 0 - 69 Property owner(s) •Ge td S ,4,,mey .�i;-c- -) Day phone 4 ZA - 3 3-Z1,11 Mailing Code Site address Nal I Izi kA f Ve Zip Code Legal description (Sub'd, Block & Lot) La -5/6 Legal description (Township, Section & Range) Lot Size --q O[o�)-_Sq. Ft. THIS APPLICATION IS FOR (gall that apply): Absorption Field Upgrade Septic Tank [� Holding Tank ❑ Privy ❑ Private Well 131� Water Storage ❑ Number of Bedrooms -:7 THIS APPLICATION IS AN: Initial ❑ Upgrade ❑ Renewal ❑ certify that the above information is correct. I further certify that this application is being made for a Single Family Dwelling and is in accordance with applicable Municipal Codes. (Signature of property owner or aulfiorized agent) Permit/Rush Fees: 3 V Waiver Fees: Date of Payment:V ��tt 2_."00 G Date of Payment: Receipt Number.13 Receipt Number: (Rev. 11/05) Douglas T. Kenley, P.E. 9806 E North Star Cirde, Palmer, Alaska 99645 (907) 746.1073 May 10, 2007 Municipality of Anchorage On -Site Services 4700 South Bragaw Anchorage, Alaska Re: Gary and Audrey Mason, Owners, Lot 127B, Kristas Subdivision, Chugiak, Alaska PERCOLATION TEST RESULTS AND GENERAL SITE INVESTIGATION REPORT This letter is a request for a well and septic permit on the above -referenced property. On April 25, 2007, an inspection was conducted on the site, consisting of approximately 45,000 square feet, which is located on Tarika Avenue in North Birchwood. The inspection revealed that the property was average treed, with spruce being predominate and some birch and poplar present. Two perc tests were performed on April 27, 2007, (see attached soil logs). Test hole #1 was dug to a depth of 15-1/2'. No ground water was observed in Test Hole #1 after monitoring. The leach field will be placed to follow the contour lines of the lot located in the area of Test dole #1. It is proposed to use two 3' wide x 6' E.D. x 35' long trenchs, and a new 1000 gallon tank for the future 3 -bedroom residence. Test hole #2 was dug to a depth of 17'. The area of Test Hole #2 is an alternate site for future use; however, Test Hole #2 had water present at a depth of 9' 11" from ground level after monitoring. On-site observation and physical survey show that a 100' well radius encroaches onto the property from two adjacent properties (see attached septic system plan design). This resulted in a narrow corridor in which the system can be placed; therefore, two 35' long trenches will be installed. The proposed system will have no measurable impact on surface or sub -surface drainage, or on drainage from adjacent lots. It appears that there is no potential for contamination of adjacent water wells or streams from known sources. Also, the proposed development will not prohibit future upgrades of any neighboring lots. Attached please find proposed design drawings for the deep trench system. If there should be any questions concerning the percolation rate or characteristics of the site, please call me at (907) 746- 1073 or 243-5372. Sin.cerely, Dougl . Kenley, P. . PE #8176 N Lo N m r D Z H ®e®aoe®o� F P >S r 1 I l 1 I 1 AUDREY MASON ;S DOUGLAS T. KENLEY, P.E. 3 $' CW c•, .«. seoa E. Ham s1ol c q Sg 3RD LOT 1278, KRISTAS S/0 '°`""' CHUGIAK. ALASKA 3- z N m m AUDREY MASON DOUGLAS T. KENLEY. P.E. a a s CM tp .SSM L x 1. S.s 4w LOT 127B. KRISTAS SUBDIVISION �"'•O•""" a CHLIGIAK. ALASKA og ego +362 L54 t A4 CC� Szy CPnt mzNg�n-� mg � n iy mg g.. z N V rytz S? AP��y Ooi � ,wmi OF�� A a 21 m aL2 aKF A� � v X 3 E $02 2 A r� > L Z > pO AUDREY MASON DOUGLAS T. KENLEY. P.E. a a s CM tp .SSM L x 1. S.s 4w LOT 127B. KRISTAS SUBDIVISION �"'•O•""" a CHLIGIAK. ALASKA mm � ns Oy t1 •-. �x2 0 C Z z g m p g AUDREY MASON DOUGLAS T. KENLEY, P.E. } e• a CM s^0^•e. 9" c wenn sl✓ PW LOT 127B, KRISTAS SUBDIVISION • V CHLIGIAK. ALASKA CA m x Cl() m K U M AUDREY MASON DOUGLAS T. KENLEY, P.E. a ig �Qa LOT 1278. KRISTAS SUBDIVISION CHUCUK. ALASKA Performed For. Legal Description: Municipality of Anchorage Development Services Department \ Building en On -Site Water and Wastewater Program 4700 South Bragaw SL P.O. Box 196650 Anchorage, AK 99519-6650 www.munl.org/onsite (907) 343-7904 Soils Log - Percolation Test Gary and Audrey Mason Date Pe _ Lot 1278, Kdstas SID Township, Range, Section: Tow �ilo 1 Accw.43i�'S CW. WAS GROUND WATER Date ENCOUNTERED? No Net Time Depth to Water S IF YES. AT WHAT DEPTH? L Depth to Water After O Monitoring? 0 E Date. 5110/07 4127107 Reading Date Gross Time Net Time Depth to Water Net Drop Presoak 1 4127107 3:48 8• ' 4:18 30 minutes 6-12/16' 1-6116' 2 4:20 g ' 4:50 30minutes 6.11/16' 1-5/16• 3 4:54 8' ' 5:24 30 minutes 6-11/16' 1-5/16' rent;uu�nun nett �• fnw "0/l PERC HOLE DIAMETER r TEST RUN BETWEEN 4�1a FT AND 5 FT COMMENTS PERFORMED BY: Fred KeNay I Dou l s 1v Kenley ( � CERTIFY THAT THIS TEST WAS PERFORMED IN ACCORDANCE WITH ALLSTATE AND MUNICIPAL GUIDELINES INE CT ON THIS DATE. DATE: S•I2.0 Municipality of Anchorage; NGINEE SEAQ}.. - Development Services Department Building Safety Division yr On -Site Water and Wastewater Program • • • • ' " • • • ' 4700 South Bragaw St. i P.O. Box 196650 Anchorage, AK 99519-6650 www.muni.org0n5ite '��'`� I KOM': (907) 343-7904 V' •• Soils Log - Percolation Test !�'��T"� Performed For. Gary and Audrey Mason Date Performed: Aphl27 22'0r- •'-, Legal Description: Lot 1278, Kdstas SID Township, Range, Section: Slope Site Plan ORC C Reading WAS GROUND WATER Gross Time Net Time ENCOUNTERED? No Presoak S IF YES, AT WHAT DEPTH? E 1 Depth to Water ARer Monitoring? / P a- 1.1) E n 6 ••�/.�.I.VTIEi� Dore: 5/10/07 30 minutes 6.15/16" 1-tne Reading Date Gross Time Net Time Depth to Water Net Drop Presoak 1 4/27107 4:14 a- • 4:44 30 minutes 6.15/16" 1-tne 2 4:46 8-1/16" " 5:16 30minules 7-1/16" 1-0/16 3 5:18 8' " 5:48 30 minutes 7-1/8" 7/8" PERCOLATIONRATE r= Im.uawwry PERC HOLE DIAMETER r TESTRUNBETWEEN LIQ FT AND a FT PERFORMED BY: 1 Dougl". K'nleY CERTIFY THAT THIS TEST WAS PERFORMED IN ACCORDANCE WITH ALLSTATE AND MUNICIPAL GUIDELINES IN EFFE�T ON THIS DATE. DATE: 9 • I•L' 0 MUNN MPAUTY OF ANCHORAGE Development Services Department Phone: 907-343-7904 On -Site Water & Wastewater Section Fax: 907-343-7997 Certificate of On -Site Systems Approval Parcel I.D. 051-144-58-000 Expiration Date: 2- 2 1? "2-021 1. GENERAL INFORMATION Complete legal description KRISTAS LT 127B Location (site address) 21675 Tarika Ave Chugiak AK 99567 Current property owner(s) KELLEHER EDMUND & NICOLE Day phone 907-406-0037 Mailing address 21675 Tarika Ave Chugiak AK 99567 Real estate agent Day phone 2. TYPE OF DWELLING: F-1 Single Family (w/wo ADU) ❑ Duplex ❑ Multiple Dwellings (Single Family and/or Duplex) 3. NUMBER OF BEDROOMS: 3 4. TYPE OF WATER SUPPLY: TYPE OF WASTEWATER DISPOSAL: Private Well El Private Septic R Water Storage ❑ Holding Tank ❑ Community Well ❑ Community ❑ Public Water System ❑ Public Sewer ❑ Waiver request for: tank within neighboring well radius Received by: COSA to be released to the engineer, unless otherwise requested by the engineer. Date: S� COSA Fee $ Waiver Fee $ Date of Payment 7 7-2 Date of Payment Receipt Number 0 2 Z ZIP COSAC 2©f .322 - Receipt Number Distance: 921 Waiver# cstl zoo ow 5. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based on procedures outlined in the Certificate of On -Site Systems Approval Guidelines for this application, shows that the on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is (are) in compliance with all applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation. I acknowledge that On -Site staff may visit the site to verify the information submitted. Name of Firm Eklutna Engineering, LLC Phone 907.406.1058 Address 19162 Mountain Rd Chugiak AK 99567 Engineer's Printed Name Curtis Townsend, PE Date 12/21/2020 ....H ........... F 6. DSD SIGNATURE i ... •l' • Cum's L.�Townsen� • • AV - for ` System #1 Approved for bedrooms �p ' Date. ��2 —zr� W ( �!FC�; No. CE 1190-1' . -c,�g System #2 Approved for bedroomse��F�fpp�;�FE851G1Lt``�� �g��_1 - Disapproved Conditional approval for bedrooms, with the following stipulations: Original Certificate Date: The Municipality of Anchorage Development Services Division (DSD) issues Certificates of On -Site Systems Approval (COSA) based only upon the representations given in paragraph 5 by an independent professional civil engineer registered in the State of Alaska. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. 7. ATTACHMENTS: COSA Checklist X Nitrate Advisory Septic System Advisory Arsenic Advisory Well Flow Advisory Other COSA Checklist blue sheet Legal Description: KRISTAS LT 127B If more than 1 septic system on lot: COSA Checklist # A. WELL DATA ❑ Well log is filed with Onsite (or attached) Date drilled 3/2012 Total depth 280 ft Cased to 74 ft ❑ Sanitary seal is functioning correctly ❑ Wires are properly protected Casing height (above ground) '24 in. Date of flow test for COSA 7/9/2020 Static water level at beginning of test 20 ft. Comments B. TANK DATA Age of tank(s) 8 years Tank type/material septic S CgO Measured operating fluid level in septic tank ❑ Standpipes/foundation cleanout per record drawing Date of pumping 06/19/2020 Parcel ID: 051-144-58 of Structure served by this system D. ABSORPTION FIELD DATA Which system tested (date installed) 2012 ❑ ALL standpipes present per record drawing Total measured depth from grade 9.7 ft (max) Measured depth to pipe invert from grade 3 ft (min) ❑ N/A — pressurized field ❑ Monitor tubes go to bottom of effective. If not, state depth into effective ❑ Code -required soil cover over field ❑ System presoaked (Required if vacant for greater than 30 days prior to date of test) Gallons introduced gallons Comments/Deficiencies: depths of water in west monitor tube/east monitor tube COSA Checklist yellow sheet Well production at time of test 3.1 gpm Water storage tank volume 500 gallons Well disinfected for coliform test? ❑ Yes ❑ No ❑ Coliform bacteria is Negative Nitrate mg/L ❑ Nitrate less than MRL (ND) Arsenic 2.498 ug/L ❑ Arsenic less than MRL (ND) Collected by Curtis Townsend Date of Sample 721912020 C. LIFT STATION ❑ Required maintenance com Age of lift station y Lift station material/ Adequacy test date 719/2020 Results ID Pass For 3 bedrooms Fluid depth prior to test 46/48 in Water added 450 gal New depth 51/57 in Elapsed time 1440 min Final fluid depth 48/52 in Absorption rate '450 gpd Any rejuvenation treatment (past 12 months) If yes, enter date E. SEPARATION DISTANCES From Private Well on Lot to: (Please enter distances if less than required or if community well) Septic Tank/Lift Station on Lot > 100' 0 Yes Community Sewer Manhole/Cleanout > 100' ❑✓ Yes if No ft M Yes if No ft Neighboring Tank > 100' M Yes if No ft Private Sewer/Septic Line > 25' F71 Yes if No ft Absorption Field on Lot > 100' Q Yes if No ft Holding Tank > 100' ❑✓ Yes if No ft Neighboring Absorption Fields > 100' ❑ Yes if No 92 ft Water Main > 10' Animal Containment > 50' Yes if No ft 0 Yes if No ft ❑✓ Yes if No ft Water Service Line > 10' ❑✓ Yes if No Manure/Animal Excreta Storage > 100' If septic tank is under driveway Community Sewer Main > 75' M Yes if No ft M Yes if No ft From Septic/Holding Tank on Lot to: (Please enter distances if less than required) Building Foundations > 10' 0 Yes if No ft Surface Water > 100' P Yes if No ft Property Line > 5' ✓v Yes if No ft Wells on Adjacent Lots: 0 Absorption Field > 5' 0 Yes if No ft Private Wells > 100' ❑ Yes if No 92 ft Water Main > 10' M Yes if No ft Community Wells > 200' ❑✓ Yes if No ft Water Service Line > 10' ❑✓ Yes if No ft If septic tank is under driveway comment below From Absorption Field on Lot to: (Please enter distances if less than required) Building Foundation > 10' IZI Yes if No ft If absorption field is under driveway comment below Property Line > 10' Q Yes if No ft Wells on Adjacent Lots: Water Main > 10' 0 Yes if No ft Private Wells > 100' 0 Yes if No ft Water Service Line > 10' ❑✓ Yes if No ft Community Wells > 200' F Yes if No ft Surface Water > 100'✓❑ Yes if No ft F. ENGINEER'S COMMENTS OSV201039 issued for septic tank within neighbor well radius G. ENGINEER'S CERTIFICATION I certify that l have determined through field inspections and review of Municipal records that the above systems are in conformance with MOA COSA guidelines in effect on this date. COSA Checklist yellow sheet 49 ....:s .. o.. curb$ L'fov?se 2, Date 1Z FG, No. CE 11904 • c� r sTF�FD � uOPti `� N G I N EER%1- Municipality of Anchorage P.O. Box 196650 a 4700 Elmore Road Anchorage, Alaska 99519-6650 e (907) 343-7904 ® Fax (907) 343-7997 http://www.muni.org/Onsite Development Services Department On -Site Water and Wastewater Section x x x x VARIANCE/WAIVER REVIEW x x x x Waiver#: OSV201039 COSA#:OSC201322 Permit#: PID#: 051-144-58 Legal Description: Kristas Lot 127B Engineer: Eklutna Engineering Applicant: Edmund & Nicole Kelleher Your request for a waiver of the required 100' feet horizontal separation from the septic tank to the private well on Kristas Lot 127A has been approved. The approved separation distance is 92.0 feet. See engineer's waiver request for justifications. This waiver approval applies to the existing septic tank only. Any future upgrade to the on-site F wastewater disposal system will require all separation distances be met or another approval from this department. ■ R R R R R R R R R■ ... ■ R R R R R R R R R R R R R R t R R R■■ R R R R R R R R R R R R R R R R R R R R R R R R R R R■ .... ■ R R R R R R R R R R t F Waiver is Granted: X Waiver is not Granted: J02 Date: 7/02 I Q,� U Approved by: Name of Reviewer ............................ ■ R R R R R R H R.R ■ R R R R R R R R R R R R R R R R R R R R R R R R R R■■ R R R R■■ R R R R I F **** VARIAN C EMAIVE R REVIEW **** Eklutna Engineering, LLC curtistownsend@gmail.com July 24, 2020 Subject: Kristas Lot 1276 Septic Tank to Well Waiver Request OSC201322 During a COSA action in June 2020, it was discovered that the septic tank on the subject property was 92' away from the western neighbor's water well. The legal description of the western neighboring property is Kristas Lot 127A. I am applying to request a waiver for the septic tank to well separation distances. The following justifications are provided for your consideration. When reviewing the documentation for Kristas Lot 127A, there is no well log present. There is a record of one water sampling completed in 1986 and the results were 'satisfactory'. A Health Authority Approval in 1986 described that the well was drilled in 1973, that it is 54' deep and cased to 33'. The pump was set at an elevation of 31'. Static water level is 19'. Let us review the well log for the subject property to better understand the soils below these properties. In March 2012, a 280' deep well was drilled on the subject property (Kristas Lot 1275). Starting at a depth of 50' is a layer of hardpan. This hardpan continues down to the bedrock. The bedrock layers start at a depth of 74' and extend to the bottom of the well. Water was described as being present just above the bedrock layers. The confined aquifer is protected by the hardpan layers above that will protect it from surface contamination. The ground level at the water well on Kristas Lot 127A is at higher elevation than the septic tank on the subject property. Should sewage overflow the septic tank, it would drain away from the western neighbor's well. Water samples on the subject property were tested in June 2020. The test results show that Coliform is absent, Nitrate is 0,041 mg/L and Arsenic is 2.555 ug/L. For the above reasons, we request that the waiver be granted for this current tank location Sincerely, Curtis L. Townsend, P.E. "�P � �Lgs�9l�I * .49 TH ,.. . 0' T .......... Date zr No. CE 11904. �aV� A li f�PROFESSI4N�V_ FA 1PF) A 1 WELZ---- HOUSE E� G/ EXISTING 6 x 6' EFFE( DEPTH THE HOU NICOLE AND ED KELLEHER : �P�E OF �(�5��♦♦ 21675 Tarika Ave Chugiak, Alaska 99567 �•� KRISTAS LOT 1276 r 49T—" OSC201322 00 ... ... f� ......CURTI........................ EKLUTNA ENGINEERING, LLC ..... DATE: 7/15/2020 �cuRrls Tow �, =: lvsE�vD.:: f G) . 19162 MOUNTAIN ROAD DRAWN: CLT �j's':. No. 11 04 �� CHUGlAK, ALASKA 99567= (907) 355-9820 SCALE: 1" 40' +##]N_ PID: 051-144-58 SHEET 1 OF 1 mmxrrr+r Municipality of Anchorage Development Services Department Building Safety Division On -Site Water and Wastewater Program 4700 Bragaw Street P.O. Box 196650 �I Anchorage, AK 99519-6650 wvsw.m (./ v.muni.org/onsite (! S (907) 343-7904 ��� ► V CERTIFICATE OF ON-SITE SYSTEMS APPROVAL (ajy% FOR A SINGLE FAMILY DWELLING Parcel I.D. 051-144-58 COSA # QcrS is 3 a 3 Expiration Date: ! I' _2 1. GENERAL INFORMATION Complete legal description Lot 1278, Kristas Subdivision 10 Location (site address) ran I a°enue, Chugiak, AK 99567 Current Property owner(s) Troy Davis Homes, Inc. Day phone 357-9394 Mailing address 165 E. Parks Highway Wasilla, AK 99654 Lending agency Day phone Mailing address Real Estate Agent Day phone Mailing Address Unless otherwise requested, COSA will be held by DSD for pickup. 2. NUMBER OF BEDROOMS: Three (3) 3. TYPE OF WATER SUPPLY: TYPE OF WASTEWATER DISPOSAL: Individual Well✓❑ Individual On-site ❑✓ Individual Water Storage ❑ Individual Holding Tank ❑ Community Class Well ❑ Community On-site ❑ Public Water System ❑ Public Sewer ❑ The Municipality of Anchorage Development Services Department (DSD) issues Certificates of On -Site Systems Approval (COSA) based only upon the representations given in paragraph 4 by an independent professional civil engineer registered in the State of Alaska. Certificates of On -Site Systems Approval are required for the transfer of title (except between spouses) for properties served by a single-family on-site wastewater disposal and/or water supply system. DSD also issues COSAs upon request to homeowners. Certificates of On -Site Systems Approval are valid for 90 days from the date of issue for properties served by a private or Class C well and may be reissued with new water sample results. (Certificates may be reissued for a period of up to one year with valid water samples.) Certificates are valid for one year for properties served by Class A or B wells or a public water system. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. 4. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based on procedures outlined in the Certificate of On -Site Systems Approval Guidelines for this application, shows that the on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate for the n6mber of bedrooms and type of structure indicated herein. I further verify that based on the information of§tained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation. Name of Firm Anderson Engineering Phone 522-7773 Address P.O. Box 240773 Anchorage, AK 99524 Engineer's Printed Name Michael E. Anderson, P.E. 5. DSD SIGNATURE Approved for bedrooms. . Disapproved. D=fes 8/1/2012 Conditional approval for bedrooms, with the following stipulations: Attachments COSA Checklist X Septic System Advisory Well Flow Advisory Nitrate Advisory Arsenic Advisory Maintenance Agreements Supplemental Engineer's Report Other By: /eta Original Certificate Date: y 2 (Rev. 1 M5) Municipality of Anchorage R . • '� Development Services Department Building Safety Division On -Site Water & Wastewater Program s 4700 Bragaw Street P.O. Box 196650 Anchorage, AK 99519-6650 www.muni.org/onsite (907)343-7904 CERTIFICATE OF ON-SITE SYSTEMS APPROVAL CHECKLIST Legal Description: Lot 12713, Kristas Subdivision Parcel ID: 051-144-56 A. WELL DATA Well type Private If A, B, or C provide PWSID # _ Well Log (YIN) Y Date completed 3/15/2012 Sanitary seal (YIN) Y Wires properly protected (YIN) Y Total depth 280 ft. Cased to 74 ft. Casing height (above ground) >24 in. FROM WELL LOG AT INSPECTION Date of test 3/15/2012 Static water level 22 Well production 1.8 g.p.m. 9 - p.m -WATER SAMPLE RESULTS: Coliform 0 colonies/100 mL Nitrate .405 mg/L Arsenic: Nil) mg/I Date of sample: 7/20/12 Collected by: JK13 B. SEPTIC/HOLDING TANK DATA Tank Type/Material Steel/Septic Date installed 3/16/12 Tank size 1,000 gal. Number of Compartments Two Cleanouts (YIN) Y Foundation cleanout (YIN) Y Depression over tank (YIN) N High water alarm (YIN) N Date of pumping New construction Pumper C. ABSORPTION FIELD DATA Date installed 3/16-17/12 Soil rating (g.p.d./ftZ or ft2tbdrm).6 GPD/SF System type Deep Trench Length 64 ft. Width 3 ft. Gravel below pipe 6 ft. Total depth 9.5-10.5 ft. Eff. absorption area 768 ft' Monitoring tube Y Depression over field N Date of adequacy test New const. Results (Pass/Fail) For _ bedrooms Fluid depth in absorption field before test in. Water added_ gal. New depth in. Elapsed Time: min. Final fluid depth in. Absorption rate >= g.p.d. Any rejuvenation treatment (past 12 mo.) (YIN & type) If yes, give date D. LIFT STATION Date installed Size in gallons Manhole/Access (Y/N) "Pump on"level at _ in. "Pump ofr' level at —in. High water alarm level at in. Datum Cycles tested Meets alarm & circuit requirements? E. SEPARATION DISTANCES SEPARATION DISTANCES FROM WELL ON LOT TO: Septic tank/lift station on lot >100' On adjacent lots >100' Absorption field on lot >100' On adjacent lots >100' Public sewer main >75' Public sewer manhole/cleanout >100' Sewer /septic service line >25' Holding tank N/A Animal containment areas >50' Manure/animal excrete storage areas >100' SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK ON LOT TO: Building foundation >5' Property line >5_ Absorption field >5' Water main NIA Water service line >10' Surface water >100' Wells on adjacent lots >100' SEPARATION DISTANCE FROM ABSORPTION FIELD ON LOT TO: Property line >10' Building foundation >10' Water main >10' Water Service line >10' Surface water >100' Driveway, parking/vehicle storage >25' Curtain drain None Noted Wells on adjacent lots >100' F. COMMENTS: G. ENGINEER'S CERTIFICATION doAV h'LP'��< . 1 certify that I have determined through field inspections and 49� review of Municipal records that the above systems are in I•� conformance with MOA COSA guidelines in effect on this date. Engineer's Printed Name Michael E. Anderson, P.E. ,c�+��' Date 8/1/2012 ,f 'pfd'• .: COSA Fee $ Date of Payment % j I ✓' oZ Receipt Number 6 R L175-6 (Rev. 11/05) Waiver Fee $ _ Date of Paymenl Receipt Number 10