Loading...
HomeMy WebLinkAboutT12N R4W SEC 10 LTS 19 N2 & LT 20 NW4T12N R4W Sec. 10 Lot 19 N2 & 20 NW4 #011-152-31 Inspection report not approved. Not Eligible for COSA Engineer: Legal Description: Permit: Report Type: Municipality of Anchorage P.O Box 196550 4700 Elmore Road Anchorage, Alaska 99519-6650 (907) 343-7904 Fax (907) 343-7997 hftp://www.muni.or_qlonsite Planning and Development Services Department On -Site Water and Wastewater Program On -Site Sewer/Well Submittal Comment Sheet KYLE DENTON T12N R4W SEC 10 LTS 19 N2 & 20 NW4 SW070082 WellSeptic As Built Review Completed By: The attached paperwork has been reviewed and is being returned for the following reasons: 1. Separation distance well to septic service line. Install letter. 3. Not enough square footage in trenches for 5 bedrooms. 4. Swing ties. 5. Pipe used. 6. Total depth ? V'Uell needs better grading. %eReserve site. Per SW070082 WellSeptiCompleted By: Report e: As Built Review The attached pa rwork has been revie and is being returned for the following reasons: 1. Separatio istanc ell to septic service line. 2. Install letter. 3. Not enou u footage in trenches for 5 bedrooms. 4. Savin " s. 5. P" used. otal depth ? 7. Well needs better grading. 8. Reserve site. 1/23/2013 Municipality of Anchorage ° e Development Services Department Building Safety Division On Site Water and Wastewater Program, 4700 Elmore Road P.O. Box 196650 Anchorage, AK 99507 Page of www.cLanchorage.ak.us (907) 343-7904 ON-SITE WASTEWATER DISPOSAL SYSTEM AND/OR WELL INSPECTION REPORT Permit Number: SW 0-7005 Z- PID Number: Name: Wastewater System: New ❑ Upgrade Address: S f ABSORPTION FIELD Phone: Number of Becdro-oms: ip 3 _ Z1 S J Deep Trench 0Shallow Tren h 13 Bed ❑Mountl ❑Oher. LEGAL DESCRIPTION Soil Rating: / Total Depth from original grade: 0.6. GPD/Fl 1p, . O Ft, Block: Let:/ � / Subdivision U Depth Depth ro pipe bolt o from original grade: Gravel depth beneath pipe: Z,p /V S ZO 'v / L .O Ft. .S Fl. Tovau hiO Range: section: Fill added above original grade : 7.0 Gravel Length: Ff. Z Ft. Well: New ❑ Upgrade Gravelwidth: 2.0 Numberoflines: Distance between lines: R. �� Ft. Classification (Priya B, C): Total Depth:Q Cased topQ Total absorption area: Piga Material: 9V FL I.& Ft. 175-0 Fe If r</ i�,eliG IN Date pgrill :7.�- J �7� Static Wafer Level: Ft. Installer L'L /��/✓%D� Date Installed Q 6O y ,9 Yield l 2S Pump Set an /'70 Casing Hertint Above Ground: Z.0 TANK GPM FL Ft. SEPARATION DISTANCES Ie.Septic ❑ Holding ❑ S.T.E.P. ❑ Other: To Septic Absorption Lift Holding ublic/Private Manufacturer Capcaci�ty: From Tank Field Station Tank Sevver Line C7 /ZE.E /500GaI. Well /(0:9 16-3 Material: '5 7-C je G_ Number of Compartments: 2 surface Water 3? p 73 LIFT STATION Size: Manufacturer. Lot Line Gal. Foundation , (/ / / °Pumpowlevelat: 'Pump off level al: High water alarm at: In. in. in. Pump Make B Model Electrical Inspections performed by: Curtain Drain Remarks: BENCH MARK f $ t ha' � Ileamption: Assumed Elevation: TGS% FI. rima Inspections by: 6 Q Engln"I VOF Ott performed let F A4 2ndik414 Development Services Department Appro far Conditional Approval Date: ®'•' "'°° ""` ' ° '°"°"`° Kyle A. Denton4 10 e zu ', ♦ CE -9954 R(Reev4ewed and approved by: Date: ®S�PROFEOSkoo � I 1 D ERTER ® ® -L BE PERFORMED IN ACCORDANCE MATERIALS SHALL CONFORM TO D.E.C. REGULATIONS. RENCH AS INDICATED. i.UM OF 2' OF RIGID INSULATION SEPARATION FROM ALL SLOPES z N m 25% H e RIGID INSULATION BOARD OVER ANY O_ 4' OR LESS OR AREAS NORMALLY � O N N 0 01 SNOW. YO r.+ ® ® IURBED DURING CONSTRUCTION OF AND DISTRIBUTION AREAS SHALL BE 2" OF TOPSOIL AND SEEDED. N �z0� \ FLOW EXISTINGSPUTTER \` �® PRIVATE=100'LL � TES7 HOLE #1: 15-30 MPI 1 GPD/SF \ Y HOUSE 5 BEDROOMS X 150 = 1250 SF 0.6 GPD/SF THE .OW PERFORATED PIPE: REPLACEMENT SEPTIC SYSTEM RPTION AREA = 1250 SF = 704.2 FT 2 TREN ES, 52' LONG X ;RAVEL DEPTH 2 x 6' fi DEEP X 2' WIDE _ 2 = 52.1' (USE 52') I— W W 0 J Q W 1E W ....... 4 9 .°°°°°°°°°°°...o.... j Kyle A. Denton a CE -9954 'ORQ 11 FE ,S�0 w m 'ERFORATED DRAIN PIPE o z FILTER FABRIC o J `1 U 10 R ---a 2" RIGID INSULATION 100.0' GR ML —1' -2' 95.5'-- FILLER L.; ,•r a z z 5 FABRIC TYP m " c y 3 e k 'sr a` J c 90.0'- -° TRENCHES 52' LONG, 15' DC APARTFh 84.0'- - - GP SP _16. CROSS SEG -Built N.T.S. 3 z N m O H e O_ � O N N 0 01 YO r.+ 01 �a N �z0� m O c� e e^� ICY pn o 3 �T MAY -19-2008 08:05A FROM: TO:5612184 P.1 Municipality of Anchorage Development Services Department Building Safety Division On -Site Water and Wastewater Section 4700 South Bregaw St. P.O. Box 196650 Anchorage, AK 99519-6650 www.muni.org/onsite (907) 343-7904 Attention: Proper"wner shall provide a well log to the DSD within 60 days of well completion. Permit Number: SWO70082 Dare of Issue: May/30/2 ParcelIdentitication unt —1 — 31 Is well located at approved permit location? (X) Ycs ur ( )No I4ftp Dril'un�, Inc. Well Lo 'Water Weir OrliT ng and Pump Service 4tttcf0r4c, %&sfra (907) 345-0593 Drilling Started: 29r04 r2007completcd:09/ 05,2007 City/Borough: Subdivision: BLOCK: I LOT I properly Owner Name&Address: Kyle A. & Kristin A. Denton 9300 Jaciaire Lane Site:8521 Emerald Street Anchorage 19N2 ON 4 c Meridian Tonmahip 12N Range 4W Section _10 ,_ '/a of __'A of __%a of _''/n T BOREHOLE DATA(frOm top Of CHSIng)Depth Drilling method: (X) Air rotary, ( ) Cable tool, Other ,. Material-. Type, Color & wetness from To Well usc: ( ) Public supply, (X) Domestic, Other_ stickup 0 2 Depth or hole: 198 fl, Casing stickup: 2 ft Casing typaSteel Thickness: _.250 , inches Casing diameter: � 8 inches Casing depth: 19898 It fill 2 4 Liner type: - Diameter: - inches Depth: - tl pest 4 12 Static water (from top of casing): 45 ft on D9/05 12Q07 Pumping level & yield:. feet atter____ hours at ,_„__ gpm Recovery rate: 25 bpm, Method of testing: airlift sand & clay layers 12 65 Development method: airlift Duration: 1 hour sand 65 120 Well intake opening type: (X 1 Open end. ( ) Open hole, Other Semcncd: Start: - fl, Stopped ___.7__ It wet sand 120 180 Screen type: - Slotlmcsh size: - Perforated: Start: - It, Stopped: - ft wet sand w/ clay layers 180 193 Start: - 11, Stopped: - fl Note: .................. ...................... I ............... ................. I., ....... I.............. coarse gravel w/ H2O 193 198 Grout type. _ bentonite volume - Depth, from ground su- ace to 20 (i Pump intake depth: _ _ It Pump size: _ hp, Brand name: Was well disinfected upon completion? (X) Yes, ( ) No Method of disinfcciion:(ealCi)Jm.H chlorke..(Chlorine.)... Driller comments/ disclaimers: ............................................I............... .. ................_.."---........ .......................................... ....... ........... .... .... _. _.-__._.._--------- ............................... .................................................................................................I........... Well drillernamc:._.Jnhnny Kay Company name: .... He.fty. DnlPngt. Inc. ........................................ Mailingaddress: 354D Akula Dr_ city: Anchorage _ state: Aj� zip 99516 Phone number: ( 907 ) J45 ..-.0593 fa)c345-4700 Drillers signature: Municipality of Anchorage Development Services Department Building Safety Division On -Site Water and Wastewater Section 4700 South Bregaw St. P.O. Box 196650 Anchorage, AK 99519-6650 www.muni.org/onsite (907) 343-7904 Attention: Proper"wner shall provide a well log to the DSD within 60 days of well completion. Permit Number: SWO70082 Dare of Issue: May/30/2 ParcelIdentitication unt —1 — 31 Is well located at approved permit location? (X) Ycs ur ( )No ump Installation Log,,, of IA -r ABOVE GROUND CAS NO LOCADON: w'�e� eutE Kl/% / A. 44- l�r,in + oh DATE C) 0 0? Pftless Adapter Maanfaetarer'sp Name: Cqa"1 �� �) 07 j Pitless Adapter Installer. �e<'s? ail I;t�5 �1L' r PUMP TYPE 5by� 5 ale "' aot>Et I`� SC1E10-�2t� a- 'II SERIAL R Pam '^ < t 1 motor tFo11� Sea /I DROP TYPE: Type p0 ,n,,, N a Camiftion OyVb . : Coneftion ems✓ t EUXTRICAL: vats X10 � An" r ' WATER T)UGt: Type Sim �I LAI , rt L HELL CASINGS SIM ,n Dio. T>pf TFE✓ CASED NOTE: Fran V N T,i3 i nr N RITAKE STRUCW : TTPe (�}7P/t Ena- Fran To -..._ am NOLE: Flan - To r commmm well was disinfected upon completion. method: calcium hypochlorite. DHCCing, Znc.�l _ Water WeCCand Pump Service Anchorage, ACaska 907) 345-0593 MUNICIPALITY OF ANCHORAGE Development Services Department On -Site Water d Wastewater Program / I p lO� 1 4700 South Bragaw Street 6 �j 1'P?ro P.O. Box 196650, Anchorage, AK 99519-6650 (907) 343.7904 ONSITE WASTEWATER DISPOSAL SYSTEM / WATER SUPPLY PERMIT Initial Permit Number: SW070082 Legal Description: T12N R4W SEC 10 LTS 19 N2 & 20 NW4 Design Engineer: 0881 KYLE DENTON Owner Name: KYLE A. & KRISTIN A. DENTON Owner Address: 9300 JACLAIRE LANE ANCHORAGE. AK 99502 - Date Issued: May 30, 2007 Expiration Date: May 29, 2008 Parcel ID: 011-152-31 Site Address: 8521 EMERALD STREET Lot Size: 76417 SO. FT. Total Bedrooms: 5 Permit Bedrooms: 5 This permit is for the construction of: 0 Disposal Field ❑✓ Septic Tank ❑ Holding Tank ❑ Privy QQ Private Well ❑ Water Storage All construction must be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal Code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72 ) and Drinking Water Regulations ( 18AAC80 ). 3, The engineer must notify DSD at least 2 hours prior to each inspection. Provide notification by calling (907) 343-7904 ( 24 hours ). ( Not required for a Water Supply Permit only ). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must be either: A. Open and closed on the same day. B. Covered, sealed, and heated to prevent freezing. Received By. Date 0.5407 Date: 5 Municipality of Anchorage • Development Services Department Building Safety Division On -Site Water and Wastewater Program 4700 Bragaw Street P.O. Box 196650 Anchorage, Alaska 99519-0650 www.muni.org/onsite (907) 343-7904 Parcel I.D. ON-SITE SEWER/WELL PERMIT APPLICATION FOR A SINGLE FAMILY DWELLING 01115231-000 KQ„te„ to Cllr+ Property owner(S) Kyle A. and Kristin A. Denton Day phone 907-301-9793 Mailing address 9300 Jaclaire Lane Zip Code 99502 Site address 8521 Emerald Street Zip Code 99502 Legal description (Sub'd., Block & Lot) Legal description (Township, Range & Section) T12N R4W SEC 10, LTS 19 N2 & LT 20 N J)LI Lot Size 76,417 Sq. Ft. THIS APPLICATION IS FOR (® all that apply): Absorption Field I] Septic Tank El Holding Tank ❑ Privy ❑ Private Well Water Storage ❑ Number of Bedrooms 5 THIS APPLICATION IS AN: Initial El Upgrade ❑ Renewal ❑ I certify that the above information is correct. I further certify that this application is being made for a Sinale Family DweM)gg and is in accordance with applicable Municipal Codes. of property owner or authorized agent) Permit/Rush Fees: Waiver Fees: Date of Payment: 7 _ ;7-3 '07 Date of Payment: Receipt Number. Receipt Number. (Rev. 11/05) Kyle Denton. Me 9300 Jaclaire Lane Anchorage, AK 99502 May 22, 2007 Municipality of Anchorage Development Services Department Building Safety Division On -Site Water and Wastewater Program 4700 Bragaw Street Anchorage, AK 99519 Re: Water and Wastewater Design for 8521 Emerald Street To whom it may concern: A proposed 5000 square foot 4 bedroom house will be constructed on the 76,000 square foot subject property. The septic system will be designed around the 30 foot radius of T1191 previously installed by Steve Pannone for Meg and Steve Jones. The monitor tube for Tl IU is still in place. A water well is also to be installed on the property. Research of the wells in the area indicate that water will most likely be found between 250 and 450 feet. SOILS: The attached soils logs show sands with silts SP/SM from below OG to nearly the bottom of the test holes at 16' no ground water or seeps were present in the test holes and inspection of the monitoring tubes since May 1 have revealed no water at the original test hole depth of 16'. Percolation tests conducted by Mr. Pannone provided a perc rate of 27 minlin. An application rate of 0.6 gallon/day/tt2 is supported by this data. TRENCH DESIGN: Application Rate: 0.6 gallon/day/R2 Number of Bedrooms: 5 Design Flow: 750 gal/day Minimum Absorption Area: 1250 sf Effective Depth: 6 feet Width: 2 feet Minimum Length: 104 feet Install two trenches 52 feet long for primary and backup fields. 93001ocloire lone • Ilnabotage. Alotko 99502 • 907.361.2183 lam: 907.561.2184 cell: 907.301.9795 SURFACE WATER: There are no surface waters within 100' of the proposed system installation. TOPOGRAPHY: Average Topography in the area of the system installation is 5-10% slopes running E -W. The trenches arc to be installed parallel to the slope contours. The proposed septic system is being installed outside the 100' well radius of the proposed new water well. All adjacent developable properties have on site systems in use and these installations do not encroach in separation distances or otherwise adversely impact adjacent properties. CONSTRUCTION SPECIFICATIONS: All construction shall be don in accordance with AS 15.65. Kyle Denton, PE Corvus Contractors LLC OF' A4 k1lo _-J.4::...........r 1,. Demon :'00 -9954 9500 Joeloite lone • anchorage. aloilta 99502 • 907.5b 1.2185 e D w� —I m D x \ m bll a F 9 V) O K N A N a� ti� 8' Zll M D D N pZ Zll:� o-------- ------ :;.<,.<;6 EMERALD STREET <II � e cn m s n o 40l _ H 40l 2 9 001- 21 "j 00 �O O l N� Zm _ TN �cD O NC KBO f�l� N NEWBUM1O o FF ELEV 99.0' � 96 FOUNDATION l n CLEAN OUT CLEAN OUT y O •? h L S¢ CLEAN OUT 'Q6 5a 25 : g� CLEAN WTA,jN I gF � � tib CLEAN OUT . L $ ZL 2Lr.1 rVI K i; ��'.`7,6 � iu N �zt, i•i �y 1.L � Q> � Yo g cif �i ib Q8 N {yq} �� II N i 8OO9 � ':>r �•,:•�i s � k • Q y� � Z SOA � > ��Fi fipg' G z N tI •��.1 P . I l � � h ✓A fel O � C 'pU 1fp't1 Q ��:/��• 1 Y1 O -J LCA �Q( � C3s1 `• .�,; �.�•��' Q � I"� N � 002 MONITOR TUBE CLEAN OUT Wastewater Disposal System DMcMay 21,2007 Scale: l' -V Dram Br. iu Grid No: SW 2325 C3ecW Br KAD Kyle Denton, PE 9300 Jaclaire Lane Anchorage, Alaska 99502 Phone: (907) 301-9793 Fax: (907)561-2184 Kyle's House N2 Lot 19, NW4 Lot 20, S10, T12N, R4W 8525 Emerald Street Anchorage, Alaska 99502 F . v 4 �m : •: O N 10 iyrib'= � ray aaat�yffA ��C.>� r� n Pannone Engineering Services, LLC Consulting Engineers May 3, 2003 Mr. & Mrs. Steve & Meg Jones 921 West 6th Ave, #200 Anchorage, AK 99501 Dear Mr. & Mrs. Jones: Subject: North Yz Lot 19, NW 'K Lot 20, S10, T12N, R4W Soils Investigation P.O. Box 102954 .ge, Alaska, 99510 )07)272-8218 Fax You contacted me to perform a soils investigation on the subject lot to assist you in purchasing this lot. The purpose of the soils investigation was to determine the suitability of the discovered soils for the construction of an onsite soil absorption septic system for afive bedroom multi- family house. The soils investigation and percolation test was conducted on April 21, 2003. Two test holes were excavated on the lot. The attached soil logs shows that we encountered a variety of soils in the test pit. I have attached the soillogs for your reference. The soils in the test pit are acceptable for a soil absorption system (the poorly gradedsand with silts between approximately two feet (2) below ground level and 15 feet below ground level with a percolation rate between 15 and 30minutes per inch.) No ground water or bed rock was found in the test hole. ADEC Regulations govern for multi family homes, and require a minimum of four (4) feet vertical separation between the bottom of a soil absorption system and ground water for a conventional system and six feet (61 to bedrock or other impermeable layers (tight silts and clays). Additionally, the accepting soils must have a percolation rate of less than 120 minutes per inch. In conclusion, the soils investigation shows that a conventional soil absorption system can be installed on the subject lot based on the soils discoverer) the percolation test performed, and the ground water monitoring conducted to date. I would recommend a conventional trench type system, with the bottom of the trench at ten feet below ground level, and six feet (6) of drain rock below the perforated lateral drainpipe. The trench would be 105 feet long. A 1500 -gallon septic tank is required for a five -bedroom house. The estimated design cost would be approximately $2,000 and the installation cost would be approximately $10,000 to $12,000. If you have any questions or concerns, please contact me at 2273522 or 272-8218. Sincerely, Steven R. Pannone, P.E. Attachments: C:\Work\Letters\N2L19 NW41,20 S10.Soils.doc n r�l 1 .•'�E........... 111 PANNONE EI4OIIaCERIIO SM3MCES �•' , ♦♦♦ P.O. BOX 107934 i �a' 49LH s ANCEDRAGE, AX 99310 � "" ••••••••• + «� 19M 777-8718 ♦ %Steven R. Pannone; or ;s.. ♦1� �No. CE �8149-•� i PZMVM® FOR: 8Wm b 1lai Jame DATZ MWORIICD. 4-01-08♦11 -"" . :..� LiAAL N7 Lot 19. NW 4 Lot 70. 810. T17NR4WMUL all Ter HOti 1 OR WAOt UM 1 1Ovwa 9 am 4 6 6 7— al pm gmAn a- 9— 10 11 17 is WAS OROU1lD WATiit taco 14 lm'COt1wrxz 4 Wo 16 leaeb Qndw M Vg AT WHAT 16 neY Oa'/Q O�A/Omd Opp .p. ?idt HOfi HOH 17 t78pM TO WA7IIR AFTmt i�O2RDOItQi01? -.0 16 DATE: 53-03 19 70 Pla000 A11plt RATE 77 Emla/babl PZRC HOLa DI NMM 6lorhee Tib! RUN HEW1ZEN 6 IT md 7 >rT COIO�NIS: bat Teat e MM"- tW by Dam Beefs. Test Hole was vxsoaimd befts Dere twL E. PERFORItaD BY: Stereo It Paaaooe, P.I CEIMPYTHAT THIS TEST WAS PgRFO,UWW III ACCORDANCE Wll'n AIL STATE AND MUNICIPAL OUIDIalE81N EFFECT ON THE DATE OF THIS TEST. ■.Qlt Omd �ll�af 4 a` 19 oanb aNs o� -Is ill Fj Iwnt I'I ••IPlwnl 1 1 pull\ I I -e «m �tlt>R m 101 80e" 6 my Jms DAM PZVORMM. 4-41.09 LZML DLaCWMW- 114 Lot 19. NW 4 Lot 40.81% T14N R4W CqpniD- T81' HO1iHOIi 9 -" 1lem u 1 4 a 4 a al OnWaRAVIL I 70 W4, Lew 49LN I ice. lith i• ©=OEM PERMAMM RATE la tmte/bwW I 7=BT RUN BzwrnN 7 Tl' =4 9 Pr C C)NMW 8 Test bole emanated br Dan Beab. Teat Hole was =ewaked balble part teat PERMAMM RATE la tmte/bwW I 7=BT RUN BzwrnN 7 Tl' =4 9 Pr C C)NMW 8 Test bole emanated br Dan Beab. Teat Hole was =ewaked balble part teat Kyle Denton, P.E. 9300 Jaclaire Lane Anchorage, AK 99502 May 30, 2007 Municipality of Anchorage Development Services Department Building Safety Division On -Site Water and Wastewater Program 4700 Bragaw Street Anchorage, AK 99519 Re: Water and Wastewater Design for 8521 Emerald Street In response to the comments for aforementioned permit: I intend to install my own septic system for my single family home at 8521 Emerald Street. 1 own a construction company and have an Ilitachi 135 excavator suitable for this work. I am experienced in pipe laying and excavator operation and have assisted in the installation of septic systems in Fairbanks and Wasilla. In regard to the request to provide mid -point entry into the system, 1 request that this requirement be waived due to the fact that 1 will be installing both fields at the same time and alternating between the two. This should mitigate the concern of early drop out and associated bio -mat growth. Please call if you have any questions regarding these responses. Ky/c�nton, PE Corvus Contractors LLC 9500 Jaclaire tone • llnchorage. Alaika 99302 . 907.561.2183 (am: 907.561.2184 tell: 907.301.9793