Loading...
HomeMy WebLinkAboutMOUNTAIN TERRACE ESTATES #2 TR AOnsite File Mountain Terrace Estates #2 Tract A #020-121-23 MOA site visit (3/15/22): No signs that systems were installed under OSP141345 Mountain Terrace Estates #2 Tr A #020-121-23 On -Site Water & Wastewater System Permit MUNICIPALITY OF ANCHORAGE Development Services Department On -Site Water & Wastewater Program 4700 Elmore Road, PO Box 196650 Anchorage, AK 99519-6650 Telephone: (907) 343-7904 Permit Number: OSP141345 Tax Code Number: 02012123000 Work Type: WellSeptic Initial Permit Effective Dates: August 11, 2015 to August 10, 2016 Design Engineer: KEITH MOBLEY Subdivision: MOUNTAIN TERRACE ESTATES #2 Site Legal Address: MOUNTAIN TERRACE ESTATES #2 TR A G:3342 Owner/Address: JORDAN RON K 3204 YELLOWSTONE DRIVE ARLINGTON TX 760130000 Site Mailing Address: 9295 PAINE RD, Anchorage This permit is for the construction of: Y Disposal Field Y Septic Tank N Holding Tank Lot Size in Sq Ft: 417923 Total Bedrooms: 4_ N Privy Y Private Well N Water Storage All construction must be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80). 3. The wastewater code requires inspections during the installation. The engineer must notify the Development Services Department at least 2 hours prior to each inspection. Provide notification by calling (907) 343-7904 (24 hours). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must either: A. Open and Close on the same day. B. Covered, sealed, and heated to prevent freezing. Received Issued By By: Date: e % / /1 Date: g r✓ S MUNICIPALITY OF ANCHORAGE i ') Community Development Department Phone: 907-343-7904 Development Services Division Fax: 907-343-7997 On -Site Water & Wastewater Program C�I►�9 � ��.9 �L�, rX:71►��I� � � 7 X:7 �i I � r_\» � [�7d� r [�] � 1 Parcell.D. 020-121-23 Property owner(s) Ron K. Jordan Day phone (817) 277-2079 Mailing address 3204 Yellowstone Drive, Arlington, Texas, 76013 Site address Legal description (Sub'd., Block & Lot) Mountain Terrace Estate #2 Tract A Legal description (Township, Range & Section) SW1/4 SEC 6, TIIN R2W Lot Size 417,923 Sq. Ft. Number of Bedrooms Four (4) APPLICATION IS FOR: (2 all that apply) Absorption Field ❑X Septic Tank ❑x Holding Tank ❑ Privy ❑ Private Well ❑x Water Storage ❑ APPLICATION IS AN: TYPE OF DWELLING: Initial ❑X Single Family (SF) ❑X (w/wo ADU) Upgrade ElDuplex (D) F-1Rerl UFMtTALu(SF aDnd/olr Djs SS ltiple ❑ AUG 1 9 2014 THIS APPLICATION INCLUDES A VARIANCE / WAIVER REQUEST FOR: Distance: I certify that the above information is correct. I further certify that this is in accordance with applicable Municipal Codes,_ (Signature of property owlierbr authorized agent) Permit/Rush Fees: — Z(S 16 - Date of Payment: `t / ck. lI Receipt Number: A14 ye 5' Permit No. 05 10 1`1345 Permit App__- Waiver Fees: _ bate of Payment: Receipt Number: Waiver No. NORTHERN GEOTECHNICAL ENGINEERING, INC. / TERRA July 28, 2015 NGE-TFT Project # 3731-14 MOA On -Site Water and Wastewater Program 4700 Elmore Road Anchorage, AK 99517 Attn: Onsite Services Engineer RE: ON-SITE SEPTIC SYSTEM AND WELL PERMIT APPLICATION FOR MOUNTAIN TERRACE ESTATE #2 TRACT A, ANCHORAGE, ALASKA To Whom It May Concern, On behalf of our client, we (Northern Geotechnical Engineering, Inc. d. b. a. Terra Firma Testing) are requesting on-site septic system and well permits for the proposed four- bedroom single family residential dwelling located on Mountain Terrace Estate #2 Tract A, Anchorage, Alaska (hereafter referred to solely as "the site"). The site is currently undeveloped and vegetated with brush and trees. We present the site topography map with proposed developments in Figure 1. These locations were not surveyed and as such were estimated from local landmarks. The proposed dwelling driveway location is subject to change, but will still comply with the septic system and well setback requirements, and will not sit on any septic system/well components. We recommend AdvanTex treatment system for this site. A typical configuration by Anchorage Tank is provided for reference. The septic tank will be installed 4 feet below ground surface, and may be submerged in groundwater. We present the buoyancy calculation as attached. Providing proper construction in accordance with our design, the system will conform to the MOA Water and Wastewater System Codes Chapter 15.65 Wastewater Disposal. We, therefore, request septic and well permits for Mountain Terrace Estate #2 Tract A to be issued. Please feel free to contact us with any questions or comments you may have concerning the information presented in this letter. Sincerely, Northern Geotechnical Engineering, Inc. d.b.a. r pFA t� Terra Firma Testing Eva Ge, E.I.T.. Project Engineer / *: Keith F. Mobley 9Fc CE - 5066 �e ,\,D °ROFESSIONP�.�G'—" I Keith F. Moble ,� E. y President 11301 Olive Lane Anchorage, Alaska 99515 - Phone: (907) 344-5934 - Fax: (907) 344-5933 - Email: xge@nge-tft.com 0 Nr - a w 0 w II U w Z d d w 00 Z= U r FE w 0<z -,0O w II nUX 0.r <ow"v00 m r II eo ao3wll, n4 Q U h 4 Q¢ n V KOQ XKXW r�3zz¢mw U x Ow O O 00 r U � ¢ r'1 0 Z K Z O V a r w OM U J O w J w m o w a m o= ovaaaaMvl w� - � w om " w t2zo - 0 nr Iw CL w m K 00 0m a Q w r 2 U U Z U 0 0 � O�U) Y Q Z\00 K II w 0.0 o m � 0 Zp O w N g 0 3 r II to U) II �r- Q Q Q O^ K O Q- M m X W- ^ 3 z z Q U x w O� 0zo 0 �U <¢t= z w z O V m r O p Qu U O w inm>0:avl w owamN o a < M < < - O Q 3 � W W > W U W > z O Lo w (; F--� W A rn all, r ti w. I � cj O• U a � AIW w i o Z 1 o ,2" II U W AW w. 04 1 � •o O• U a � AIW w Q W u Q: Q F W N F- = z 0 Z Q ON W O f'1 2 W W Q O :D¢ LO L a W J 2 W o Q w W Q a a a ~ W ¢ _ PW9 W N O U 1- H tl W Z N LL Q Q IW - H h- Q Z J o fW Y W cJn ('� 2 U— 2 w a9 0 H1 O et O J � N co 2 O U O Q ot QII lz z (� Q z o J u IIII 0 0 W W IIIII Z Q uo M p III � o I—II W III—III_ C4� a a Q Q 0 0 °r o N C'1 /1 J H Y � h Q m I ry 0 o 7- o�\�,'� y Adw 6�+� n N U o o N/ ALL:• ` w/ 4 AdvanTexO Installation EXAMPLE SYSTEM CONFIGURATION MODE 1 A This is the most typical system configuration with the filter located above the tank and the filtrate gravity feeding to the drainfield. Model B would be similar with the addition of a pump basin downstream of the tank should there be a need to pump up to a drainfield. For more information on Mode 1 B, see page 39. NORTHERN GEOTECHNICAL ENGINEERING, INC. / TERRA FIRMA TESTING Buoyancy Force Calculation Dimensions of steel septic tank is 64 in. (5.3 ft.) in diameter x 10 ft. in length Subsurface Soil: y = 130 pcf Ground Surface 5.3 ft. Buoyancy force = 62.4 pcf x 3.14 x (5.3 ft./2)2 x 10 ft. = 13.8 kips 1 ft. of unsaturated soil = 130 pcf x 5.3 ft. x 10 ft. x 1 ft. = 6.9 kips 3 ft. of saturated soil = (130 pcf - 62.4 pcf) x 5.3 ft. x 10 ft. x 3 ft. = 10.7 kips Weight of soil wedge = 6.9 + 10.7 = 17.6 kips > Buoyancy force = 13.8 kips Friction is ignorable in this case which makes above calculation conservative. KeMobley +PFS CE - 5066 0AV AW ��i A OfES510Np�� 11301 Olive Lane Anchorage, Alaska 99515 • Phone: (907) 344-5934 • Fax: (907) 344-5933 • Email: kmobley@nge-tft.com Apr 24 12 01:37p Bill Empie 346-1916 ALASKA WATER & WASTEWATER CONSULTANTS, INC. LEGAL DES( PERFORMED (fit) 1 7 9 10 11 12 15 16 17 ORGANICS TO SM GM/ML/CL p.12 :� .lip DATE READING CLOCK NET TIME WATER LEVEL NET DRQ TIME (MINUTES) READING (INCHES? UPPER BENCH 4/11/2003 1 3:54 - 6' - 2 4:24 30 4 5/8" I 1 3 6" A A-' A - C" I - w PERCOLATION RATE 24 (MIK/INCH) - PERC. HOLE D°ti. 6 ;INCHES) 19 TEST RUN BETWEEN 3.0 FT. AND 3.5 FT. 20 �"' F A FOUR HOUR PRESOAK WAS PERFORMED: YES ❑ NO SOILS LOGGED BY: ,-' JPODY MAUS PERCOLATION TEST PERFORMED BY: MATT FISH COMMENTS: WILL REQUIRE USE OF ALTERNATIVE TECHNOLOGY TYPE SEPTIC SYSTEM PERFORMED BY AKWYlC, INC. I, JEFFREY A. GARNESS, CERTIFY THAT THIS W ERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE: r 5 �"` Illllllll Iii111J1- ]K%/_% lINN Iliflllll p.12 :� .lip DATE READING CLOCK NET TIME WATER LEVEL NET DRQ TIME (MINUTES) READING (INCHES? UPPER BENCH 4/11/2003 1 3:54 - 6' - 2 4:24 30 4 5/8" I 1 3 6" A A-' A - C" I - w PERCOLATION RATE 24 (MIK/INCH) - PERC. HOLE D°ti. 6 ;INCHES) 19 TEST RUN BETWEEN 3.0 FT. AND 3.5 FT. 20 �"' F A FOUR HOUR PRESOAK WAS PERFORMED: YES ❑ NO SOILS LOGGED BY: ,-' JPODY MAUS PERCOLATION TEST PERFORMED BY: MATT FISH COMMENTS: WILL REQUIRE USE OF ALTERNATIVE TECHNOLOGY TYPE SEPTIC SYSTEM PERFORMED BY AKWYlC, INC. I, JEFFREY A. GARNESS, CERTIFY THAT THIS W ERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE: r 5 Municipality of Anchorage Development Services Department Building Safety Division yp On -Site Water and Wastewater Program 4700 Elmore Road P.O. Box 196650 Anchorage, AK 99507 www.d.anchorage.alk.us (907) 343-7904 Soils Log - Percolation Test Performed For: Ron K. Jordan Legal Description: Mountain Terrace Estate #2 Tract A PT #4 SM' To C -,M 6- 7 - W."" Date Performed: 7/22/14 Township, Range, Section: SWI/4 SEC 6, TIIN R2W 15- 16- 17- 18- 19 - Reading Date WAS GROUNDWATER 9- Depth to Water ENCOUNTERED? No 8113114 5 10- 6 in. IF YES, AT WHAT DEPTH? NIA L Depth to Water After e 11- 7.25 in. Monitoring? 3' a 12- Date: 8112/14 13- 6 in. 15- 16- 17- 18- 19 - Reading Date Gross Time Net Time Depth to Water Net Drop 8113114 12:17 6 in. 12:47 30 min 7.25 in. 1.25 in. 12:49 6 in. 13:19 30 min 7,19 in, 1.19 in. 13:22 6 in. 13:52 30 min 7.19 in. 1.19 in. PERCOLATION RATE 25.2 (minuteMnc) PERC HOLE DIAMETER 6" TEST RUN BETWEEN 1 FT AND 2 FT COMMENTS Test hole pre-soaked prior to test. PERFORMED BY: Northern Geotechnical Engineering, Inc. ) Keith F. Mobley CERTIFY THAT THIS TEST WAS PERFORMED IN ACCORDANCE WITH ALLSTATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE. DATE: 8/18/14 Municipality of Anchorage Development Services Department Building Safety Division yr On -Site Water and Wastewater Program 4700 Elmore Road P.O. Box 196650 Anchorage, AK 99507 www.ci.anchoraae. a k. us (907) 343-7904 Soils Log - Percolation Test cz-a r Performed For: Ron K. Jordan Date Performed: Legal Description: Mountain Terrace Estate #2 Tract A Township, Rance, Section: SWI14 SEC 6. TIIN R2W 1 I 11 12 13 16- 17- 18- 19 - ITANTEX ✓"l 70 � "1 WAS GROUND WATER ENCOUNTERED? 1✓-'L� �% lit •'a + F YES, AT WHAT DEPTH? Depth to Water After Monitoring? Date: - S L 0 P E Reading I Date I Gross Time I Net Time I Depth to Water r Net Drop PERCOLATION RATE (nnut.MnO) PERC HOLE DIAMETER TEST RUN BETWEEN FT AND FT PERFORMED BY: I CERTIFY THAT THIS TEST WAS PERFORMED IN ACCORDANCE WITH ALLSTATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE. DATE: ADVANCED WASTEWATER TREATMENT SYSTEM MAINTENANCE AND REPAIR AGREEMENT BETWEEN MMCIPALPPY OF ANCHORAGE M4 TO / . r ' l THIS MAINTENANCE, AND REPAIR AGREEMENT made and entered into as of this 21 Day ofJ_ _ LI jjt L of 201 s, by and between 9M herein the "OWNER," and the Municipality of Anchorage, herein the "MUNICIPALITY." In consideration of the mutual covenants contained herein, the parties to this Maintenance and Repair Agreement agree as follows: 1. Advanced Wastewater Treatment Systems. Municipality grants permission to Owner to utilize and operate an Advanced Wastewater Treatment System (AWWTS), described as located at (legal description). Aot L +),) 7-e "t- co /_'7,4m4< #Z 7f-4 2. Definitions. Alteration. Any change to the design or function of an AW WTS that includes the installation or removal of any parts, components or pieces not included in the original construction permit and design. Certificate of On -Site Systems Approval (COSA). An approval by the Municipality of existing water and wastewater disposal systems given at the time of property sale and title transfer in accordance with Anchorage Municipal Code (hereinafter, "AMC') 15.65. These approvals certify that the systems are adequate for the homes that they support and meet the codes that were in place at the thus of system construction. Damage. Any man-made or natural change in a system that would inhibit the system from performing as designed. Maintenance and Repair. The scheduled and as needed replacement of existing parts, components and pieces of an AWWTS that were included in the original design which would allow the AWWTS to continue to perform as designed. Permit. An On -Site Wastewater Disposal Permit as required by AMC 15.65 to construct and operate an AWWTS. 3, Term. The term of this Maintenance and Repair Agreement shall begin on the date of approval by the Municipality to operate the installed system or issuance of a COSA, and shall continue while the AWWTS is in use or is operational or until the property is sold or title is transferred by the owner and a new COSA is issued to the new owner or transferee of the property. 4. Alterations Installation and Removal of Additional rauipment. Prior to performing any alterations to an AWWTS, the owner agrees to obtain an On-site Wastewater Disposal Permit from the Municipality in accordance with AMC 15.65. 5. Maintenance and Repairs. A. Throughout the term of this Maintenance and Repair Agreement, the Owner shall maintain their AWWTS in a satisfactory condition capable of producing treated septic effluent in accordance with the equipment's approval for operation in the Municipality. The owner shall enter into a service agreement with an AWWTS service and maintenance provider aooroved by the municipality and the manufacturer of the AW WTS for the entire term of the AW WTS. In addition, it shall be the responsibility of the Owner during the term of this Maintenance and Repair Agreement, and any renewals thereof, at the owner's sole expense, to pay for any and all: (1) repair(s), (2) maintenance, (3) adjustment(s), (4) replacement costs, and (5) inspection costs. B. Owner agrees to comply with all applicable ordinance, laws, regulations, rules and orders for the AWWTS. C. Upon request by the Municipality, the owner agrees to provide the Municipality a written schedule of routine maintenance and repairs which have been performed on the system. When a record of maintenance is documented and maintained by the system vendor, the owner agrees to allow the Municipality access to this information. D. Owner acknowledges that the fine for failing to maintain and repair an AW WTS may be assessed in accordance with AMC 14.60 for improper discharge. E. Owner agrees that only maintenance and repair personnel approved by the Municipality will inspect and make any necessary maintenance, repairs or permitted alterations to the system. F. Owner agrees to grant the Municipality reasonable access to test and inspect the A W WTS upon 24 hours written notice. G. Owner agrees that any sale or transfer of title of the property will not occur without a new Certificate of On -Site Systems Approval. H. Owner agrees that the A W WTS installation and maintenance requirements as provided by the A W WTS vendor/installer and approved by the Municipality are the governing guidelines for the construction, maintenance and repair of the Owner's A W WTS. I. Owner agrees to provide and maintain a telephone connection to the AWWTS as required by the AW WTS approval. 6. Non -waiver. The failure of either party at any time to enforce a provision of this Maintenance and Repair Agreement shall in no way constitute a waiver of the provisions, nor in any way affect the validity of the Maintenance and Repair Agreement or any part hereof, or the right of such party thereafter to enforce each and every provision hereof. 7. Amendment. A. This Maintenance and Repair Agreement shall only be amended, modified or changed by a writing, executed by authorized representatives of the parties, with the same formality that this Maintenance and Repair Agreement was executed with, and such writing shall be attached to this Maintenance and Repair Agreement as an amendment. B. For the purposes of any amendment modification or change to the terms and conditions of this agreement, the only authorized representatives of the parties are: a. Owner: 904 k' 19)-44 b. Municipality: Director, Community Development or designated authority C. Any attempt to amend, modify, or change this contract by either an unauthorized representative or unauthorized means shall be void. 8. Jurisdiction: Choice of Lay. Any civil action arising from this Maintenance and Repair Agreement shall be brought in the Superior Court for the Third Judicial District of the State of Alaska at Anchorage. The laws of the State of Alaska shall govern the rights and obligations of the parties under this Maintenance and Repair Agreement. 9. Severability. Any provisions of this Maintenance and Repair Agreement decreed invalid by a court of competent jurisdiction shall not invalidate the remaining provisions of the Maintenance and Repair Agreement. OWNER: By: b2� d� {signature) Date: 7 Z 3 1 5 994 k- Je-Ai(printname) STATE OF ALASKA ) ss. THIRD JUDICIAL DISTRICT ) The foregoing instrument was acknowledged before me this day of i tJ�l 20115, by Rjnr\ }C• J;Rr CN ` t} Notary Public NOT PUBLIC ALASI{A JOY A. GRAY M ission a 12��1��01 State of Ataw My ComMetlon Ewkts 0ec t, 20tt1 MUNICIPALITY: By: (signature) Date: Title: V s Slo` pi4'�o� i r' \ eaJ�,1• ��tih \\ of o ` � Zoo• -SO h yp. TEST HOIE LOCATIONS ARE APPROXIMATE n(J5 TM+tB ALASKA WATER & WASTEWATER CONSULTANTS, INC. oR+e m • ANCHORAGE. AN 99506 •. PHONE (907)517-6179 • FAX (907)336-3766 PARED FOR 644-2063 KEVIN DOYLE U. DESCRIP-nON: MOUNTAIN TERRACE SUBDIVISION #2; TRACT A OF WORK: SITE PLAN Q3c�oi J l/17/2003 NN BY: Z.T.G. LE: 1" = 200' E NUMBER: 1 OF 1 ;po, Drness: CE -7953 i.• 10 InnT 9:ntvu Garness Engineering GtogP. Ltd. WATER & WASTEWA' PHOW (907) 1,17_E,79 • FA! t?07) a3c-_c+o SOIL LOG — PERCOLATION TEST LEGAL DESCRIPTION: MOUNTAIN TERRACE SUBDMSION #2, TRACT A PERFORMED FOR: JAMES ITER DATE PERFORMED: 8/16/98 DEPTHTEST HOLE #11 (feet) ; I; 2- 3- 4- 5- 6. 7- 8• 9• 10. 11 12 13 14 15 16 17 18 GM BROWN, SOMEWHAT SOIL LOOSE w. q:' CLASSIFICATIONS OR GW --7 .. Wo GP i IML PERC. H WAS PRE GM CL GM GC OL SANDY, BROWN, ° • ; y SW MH BECOMING DENSER •; .•, ; SP CFI WITH DEPTH • SM i / OH 3:28 SC 6" 0 I GM I WITH 54T. TIGHT I P i AND BLUISH. DEPTH TO DATE GROUNDWATER 6' 8/16/98 N0.6800 P. 1 34.3- -t97 �00000 �� OF A�q�°pa �...4g1d ......°. DATC READING CLOCK I TIMF' NET TIMI- (MINUTES) WATER LEVEL NET DROP READING (INCHES) 1/ia/gE PERC. H WAS PRE SOAKED 4+ HO JRS PRIOR TO TE STING _ 1 2:58 — 6" 2 3:28 30 6" 0 3 3:36 — 6• 4 4:06 30 6• 0 19---� I PERCOLATION RATE 120+ (MINdINCII) PCRC. HOI.F DIA. 6 (INCHFS) 20 —j1—J� TEST RUN BF.1WttN 1.5 FT. AND 2.0 F1, COMMENTS: SOILS UNSUITABLE FOR ON-SITE SEPTIC. PERFOMED BY ALASKA WATER & WASTEWATER I, CERTIFY THATI THIS WAS PERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE DATE: Jan•18. 2001 2:01PM Garness Engineering Gr000. Ltd. ffM M ASTEWATER LEGAL DESCRIPTION: MOUNTAIN TERRACE SUBDIVISION #2, TRACT A PERFORMED FOR: JAMES CARTER DATE PERFORMED:- 11/18/98 DEPTH leeORG TEST HOLE #2 t 1 2 3 4 5 6 7 e 9 10 11 12 13 14 15 16 17' 18 19. 20 - GM SOIL CLA551FICATIONS NET TIME (MINUTES) WATER LEVEL READING NET DROP (INCHES) 11/18/9 '^"o":: BROWN, SANDY GW -- v ORG GP I ML Wl GMCL 1 2:53 I 6' — 01 MOTTLED SAND AND GRAVEL SW SP 3:23 MH CH ,�� 2% ..�. 1/16- '• i tti SM OH 3:25 — z✓I , SC SILTY No -6800 P. 2 DATE READING CL OC�K TIME NET TIME (MINUTES) WATER LEVEL READING NET DROP (INCHES) 11/18/9 PERC. H LE WAS PRESOAKED 4+ HO RS PRIOR TOT STING 1 2:53 — 6' — 2 3:23 30 5 5/16- 1/16- 3 3:25 — 6' 4 3:55 30 5 5/16" 1/16" PERCOLATION RAIE 120+ (MIN./INCID PERC. HOI t DIA. 6 (INCI IES) TEST RUN BETWEEN 2.0 F r. AND 3.0 FT. COMMENTS: SOILS UNSUITABLE FOR ON–SITE SEPTIC. PERFOMED BY ALASKA WATER & WASTEWATER I, CERTIFY THAT I THIS WAS PERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE. DATE: Jan•18. 2001 2:01PM Gayness Engineering Group, Ltd. No -6800 P. 3 0oo60�p�O� OF.Al. oa, ALASKA WATER 8 �'VASTEWATER ���Q 491 'S�OpOo ........... �........� ,.a..l....�.o — 1 001 OrPN RWD, w�w«.l MG(, M M P„0„L 901 1 {I Y �.. • ISOIL LOG — PERCOLATION EST 0 LEGAL DESCRIPTION; MOUNTAIN TERRACE SUBDMSION 12; TRACT A Q 1 Ga 5: 0 PERFORMED FOR: KEVIN DOYL DATE: 4/10/2003 OQ��v '. E-7953 t� (fT aD40y, *"*CI, e�g — ORGANICS TEST HOLE #3 1 = PAGE 1 OF 2 2 SOIL CLASSIFICATIONS i ilii I -:v=::3: CW -- ORG ilijli ,. yy.^. CP ML 3 �If 'ML TO SM GM // CL q r�}�++ / GC 'i; 1' OL SW MH _ sM �/; off SC ' ikjl: DEPTH TO ,� / 34 GM/ML/CL 10 11 D.O.H. TIME ((MINUTES) READING (INCHES) 12 13 2 4:24 30 4.5/8" 1 3 4;2a _ 6" 14 a 4:54 30 4 3/4_ 1/4- 15 16 17 ,5 19 PERCOLATION RArC 24 (MIN./INCII) I'CRC• HOLF DIA. 6 (INCHES) TEST RUN BCTWECN 3.0 F r. AND 3.5 FT. 20 A FOUR I LOUR PRESOAK WAS PFNFORMLD: N YES ❑ NO SOILS LOGGED BY: JODY MAUS r'CRCOLATION TEST PERI-ORMED BY: MATT FISHER COMMENTS: WILL REQUIRE USE OF ALTERNATIVE TECHNOLOGY TYPE SEPTIC SYSTEM PERFORMED BY AKWWC, INC. I. JEFFREY A. GARNESS, CERTIFY THAT THIS WAS PERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE: GROUNDWATER DATE DRY 4 10/2003 7.0' 4 17/2003 UPPER BENCH DATE READING CLOCK Nf'f TIME WATER Lr -VEL NET DROP UPPER BENCH 4/11 /2003 _ 1 3:54_ 4:54 5:24 6". — 5 6 — 30 _ 6" 4�4" Jan•18. 2001 2:01PM Garness Eneineerins Grouol Ltd. N0•6800 P. 4 ALASKA WA"1')CR R WAS7'LWA`C] 4 R �,�P q U v��dpp �..z— CONSULTA TC1� NC Y95W • PoONC 907 7 1 9 • 90 - b6 ' B5% Y4w.c<om 0. • • • • • • • . . • • SOIL LOG — PER OLATION TET 0....:„�.................... LEGAL DESCRIPTION: MOUNTAIN TERRACE SUBDIVISION #2; TRACT A Op : .Jeffrey A. Gornees: DO p CE -7953 e`�7 PERFORMED FOR: KEVIN DOYL DATE: 4/10/2003 DEPTH f e t) TEST HOLE 3 4��00oo`�a4 1 PACE 2 OF 2 SOIL CLASSIFICATIONS 2 GW 3 Li :!:a•.... GP - i t ML U GM CL a GC01- 80 4. SW MH ... . 5 w ;•+� SM off SEE SITE PLAN ON 6 a sc PAGE 1 OF 2 n 7 DEPTH TO DATE Z s O 9 z 10 O H it Q U_ 12— 13 (/1 2 4:24 30 5 5/8' J a 4:54 _30 _5 3/4' 5 4:54 6 14 U 15 -J 16 (n 17 w w 18 19 PERCOLATION RAIL 120 (MIN./INCH) PERC. HOLF DIA. 6 (INCHtS) TEST RUN BCTWECN 7.0 F r. AND 7.5 rT. 20 A FOUR tIOUR PRESOAK WAS PFRFORMED: 0 YCS ONO SOILS LOGGED BY: - PERCOLArION Tt5T PEWORMFD BY: MATT FlSHER COMMENTS: PERFORMED BY AKWWC. INC. I, JEFFREY A. GARNESS. CERTIFY THAT THIS WAS PERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE: DATE (n RCADING GROUNDWATER NET TIME. (MINUTE S) WATER I CVEL READING pf LOWER BENCH 4/11 2003 1 3:Sa DATE (n RCADING CLOCK TIME NET TIME. (MINUTE S) WATER I CVEL READING NET DROP (INCHES) LOWER BENCH 4/11 2003 1 3:Sa - 6” - - — .. 4:24 .. _ G" - _3.. .. 6 5:24 30 Jan.18. 2001 2:02PM Garness Engineering Groo, Ltd. NO.6800 P. 5 op6o0p0 r..:. OF, A1��0�.. ALASKA. WA_ TER & WASTLWA`i'�R 491 IJ 9*po -Iw+a n: u •Fe w� ui c �.uc a�a�u+c—tsoTs-strr� r e9f�...<<...� �......••....• •. •.... SOIL LOG - PERCOLATION TEST 0 MOUNTAIN TERRACE SUBDIVISION I/2: TRACT A O •..• •••.G LEGAL DESCRIPTION:_ Q Je e . Ccrness; D O PERFORMED FOR: KEVIN DOYL DATE: 4/10/2003 i (f DEPeTM TEST HOLE 4 4�4�4rooct`o��'� 1 ORGANICS SOIL CLASSIFICATIONS GW ORG .3 / >h . GP I -i MIL f GM CI - a �� GC ' OL �j •°o o SW MH _ 5 6 ii va ° ✓ SC ! 7 �/ • DEPTH TO DATF. GROUNDWATER {� 8 % // 7' 4/ 10 2003 ` J 2' 4/17/2003 -------------- •-------'•-'-----•--------- •----- 9 ----•-------------------------- .--,-- ----_ D.O.H. •a::. e. •. . 00, 10 11 12 13 _3 4:26_ 14 15 7 16 17 18 19 PERCOLATION RATE 240 (MIN./INCH) PI RC. I IOL@ DIA. 6 (INCHFS) TFST RUN BETWEEN 3.0 Fr. AND 3.5 FT. 20 A FOUR HOLQ PRF -SOAK WA.S PERFORMCD: N YES ONO SOILS LOGGED BY: JODY MAUS PERCOLATION TEST PERFOHMFO BY: MATT FISHER COMMENTS: TEST HOLE UNSUITABLE FOR ON-SITE SEPTIC SYSTEM PERFORMED BY AKWWC. INC. I. JEFFREY A. CARNESS. CERTIFY THAT THIS WAS PERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE: DATE READING CLUCK NET TIME WATER LEVEL NET DROP TIME (MINUTES) READING (INCHES) 4/11/2003 1 —_2 -- 3:56__ 6' 4:26_ _30 _.58'. 4:56 5:26 6" _S 6 _ 30 5 8' Jan.18. 2001 2:02PM Garness Ensineerina Group, Ltd. No -6800 P. 6 ALASKA `WATER �► �VASTENVATER o R,-'491 ypp p LTAN S N �» ..� _ .,.� 6901 IM �,IJ' �— O .............. ........... OD K. 995 90) 1 )- 19 N N..csnn FS—OILLOG PERCOLATION TES LECAL DESCRIPTION: MOUNTAIN TERRACE SUBWASION 12; TRACT A pp a '.J y A. Garness- PERFORMED FOR:—KEVIN DOYL DATE: 4/10/4003 s • • •'' �e'� DEPTH dP ^o\F�coo (feet) == TEST HOLE �OpD000��`g 1 =_ -• ORGANICS 5 SOIL CLASSIFICATIONS_ iii;' I .• GP ML 3 J�<' GM/ML/CL GM / 1 CL SII' iOL t ♦ SW MH r- .a :CLi FV:E SP Ak CH Olf Sm d Sc 61 00/// Cl. MIXED 8 W/ GRAVEL 10 � DATE READING CLOCK NET TIME WATER LEVEL NET j 11 �/ 12 R.O.H. 2 4:28 30 5 3/4' 14" 13 14 5 4:58 6 5:28 30 S 3 4 1/4" 15 16 17 18 PERCOLATION RATF. 120 (MIN,/INCH) PFr:C. HOLF DIA. 6 (INCHES) 19 TCST RUN BETMEN 3.0 FT. ANU 3.5 FT. 20 A FOUR HOUR PRFSOAK WAS I'CRFORMCD: N YES ONO SOILS LOGGED BY: JODY MAUS PERCOLATION TEST rERFORMCD BY: MATT FISHER COMMENTS: WILL REQUIRE THE USE OF AN ALTERNATIVE TECHNOLOGY TYPE SEPTIC SYSTEM PERFORMED BY AKWWC. INC. I, JEFFREY A. GARNESS, CERTIFY THAT THIS WAS PERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE: DEPTH TO DATE GROUNDWATER 4/10 2003 5.5' a 17/2003 DR TIME (MINUTES) READING (INCHES) 4/11 2003 1 3:58 6' — 3 4:28 - 6' - 4 4:58 _ 30 5 3 4" 1 4" , �" Jan.18. 2001 2:02P61 Gayness Engineering Grouo, Ltd. No -6800 P. 1 oF.Ac ALASKA WATER & WASTE R oATI✓��P. Lv�0 s....•,�..e,_r� �oa,nT w�. roso� • ►none: so �- I a Ax: (Y37jI11s-1'F�M'EBifaY.:ew.••. • • • . SOIL LO - PERCOLATION ST S 0....., LEGAL DESCRIPTION: MOUNTAIN TERRACE SUBDMSION /2; TRACT A Oda a .J y A. Garness; , oO PERFORMED FOR: KEVIN DOYL DATE: 4/10/2003 •. CE -7953 Q�y.•`aOp (feet) - ��DO0000��4400 TEST HOLE 6 ORGANICS SOIL CLASSIFICATIONS i GP llill:!i ML GM // / CL lk INjGM/ML/CL 4 GC e`!. UL SW MI -I •a�• ••.pl �.4'Z ! S SP CH :rC3 i SM OH Sc jjl 1 4, Cl. MIXED /' s 7 j w/ GRAVEL r " -01 ' r' 46 8 `; B,UJI. 10 — — 11 12 13 14 IS 16 17 18 PFRCOLATION RATE 240 (MIN./INCH) !'ERC. HOLF DIA. 6 (INCHES) 19 TEST RIIN BETWEEN 3.0 FT. AND 3.5 FT. 20 A FOUR HOUf2 VRCSOAK WAS PERFORMFD: 0 YES ONO SOILS I-OGGED BY: JODY MAUS PERCOLATION TCST PERFORMED BY: MATT FISHER COMMENTS: TEST HOLE UNSUITABLE FOR ON—SITE SEPTIC SYSTEM PERFORMED BY AKWWC, INC. I, JEFFREY A. GARNESS, CERTIFY THAT THIS WAS PERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE: DEPTH TO GROUNDWATER DATE DRY 4 10 2003 2.5' 4/17 2003 4/1003 _ — .. — 1 y_ 3 �4 S 6 3:59_ 4:29_ 4:29 4:59 _ _ 4:59 5:29 DATE RL:ADING CLOCK fIMF. NET TIME (MINUTES) WATER LF_VEL READING NCT DROP (INCHES) 4/1003 _ — .. — 1 y_ 3 �4 S 6 3:59_ 4:29_ 4:29 4:59 _ _ 4:59 5:29 _6"__ 6'_ 6; 5 7/8_ —_ 0' t/8^ — _ _— _ 30 30 —_ 30