HomeMy WebLinkAboutKNIK HEIGHTS BLK I LT 18Knl,*k Heights
Block I
Lot 18
#018-232-01
Municipality of Anchorage
On -Site Water and Wastewater Section • (907) 343-7904 Page of
ON-SITE WASTEWATER INSPECTION REPORT
Permit Number: OSP221228 PID Number: 018-232-01
Dwelling: ® Single Family (SF) ❑ with ADU ❑ Duplex (D) ❑ Two Single Family Project: ❑ New ®Upgrade
Name
JOHN & CHERYL ANNESI
ABSORPTION FIELD - EXISTING
❑ Deep Trench ❑ Wide Trench ❑ Bed ❑ Mound
Site Address
13200 SHELBURNE RD, ANCHORAGE
❑ Other
Phone
Number of Bedrooms
Soil Rating
Total depth from original grade
5
GPD/SF
Ft.
LEGAL DESCRIPTION
Depth to pipe invert from original grade
Ft.
Gravel depth beneath pipe
Ft.
Subdivision Block Lot
KNIK HEIGHTS 1 18
Fill added above original grade
Ft.
Gravel length
Ft.
Township Range Section
Gravel width
Ft.
Beds: Number of Lines
Distance between lines
Ft.
SEPARATION DISTANCES
To
Septic
Absorption
Lift Station
Holding
Sewer
Total absorption area
Number of trenches
Dist. between trenches
From
Tank
Field
Tank
Line
Ft2
Ft.
Well
100'+
--
25'+
TANK ® Septic ❑ S.T.E.P. ❑ Holding ❑ Other
Manufacturer
Capacity
Surface Water
100'+
--
GREER
1500 Gal.
Material
Number of compartments
Lot Line
101+
__
NA
HDPE
2
Foundation
101+
__
LIFT STATION
Manufacturer
Capacity
Gal.
Remarks
Alarm location
Electrical installed by
Installer DENALI EXCAVATION
PIPE MATERIAL House to tank 3034 d a n Tankto to 3034
Drainfield CO/MT 3034
Inspector FWCS
BENCH MARK (Assumed elevation) 100 ft
Inspection 15, 7/13/22Location
dates: 2 7/14/22
and description
3rd 4th
BOTTOM OF DECK
ON-SITE WATER AND WASTEWATER SECTION APPROVAL
Conditional
�of�t
"•�� l�
Approval: Date
•• •• •••• ••••••••••
Septic System
Approved -
% �•,• Curtis Huffman
d
Date 7 2-( -z�
CE 228992•
������1�.
.�����/
lliF�pROFESSION�`�'-C'
Note: this approval does not include well permit requirements.
\Nt�111�1
PID: 018-232-01
O �
,,D O
CtjCD
-O 8
33
in .
O O
o O
0
O
zo
z
u
LOT 7
A—C=21.5'
B—C=23,8'
A—D=24,3'
B—D=26.9'
PERMIT: OSP221228
PAVED v� "
21.9' 39� N D/W
I 7e-
01
o Ls vA
STAKED 100' WELL
BM: BOTTOM g RADIUS PRIOR
�8- OF DECK TO CONST.
A
100' WELL RADIUS CONNECTED TO
H EXISTING FIELD CO
DECOMMISSIONED CO ® C
EXISTING S.T. D MT
& INSTALLED NEW
1500 -GAL HDPE DCO
SEPTIC TANK. 5'+
TO DECK SUPPORTS ®1H
& EXISTING FIELD.
F�E�O
MT
CO LOT 18
BLK 1
0
LOT
17
SEPTIC SECTION
- SCALEi NTS
KNIK HEIGHTS BLK 1 LT 18
PREPARED FOR:
CHERYL & JOHN ANNESI
13200 SHELBURNE RD
ANCHORAGE, AK 99516
FIRST WATER CONSULTING
13030 SUES WAY
ANCHORAGE, AK 99516
907-350-9566 FirstWaterAK@gmail.com
SUPPORT SERVICES:
' OF .Azo
Ny
�THI
DATE: 22 7 22
/ / tis Huffman ,a
SURVEY. JLS rCE 128991 w
DRAWN: FWCS-7/22/2022 �aG
SCALE: 1" = 30' '%oFEssloo'
I
LENDER ROAD
I ROAD &GENERAL
PURPOSE ESMT
LOT 8
LOT 7
ANCHORAGE RECIJRDING DISTRICT.,L �
A ALASKA
FND BRASS CAP MON1;TMENT
AS -BUILT OF:
KNIK HEIGHTS SUBDIVISION � = FND 5!8" REBAR
LOT 18 BLOCK I PLAT P -452B
SURVEY CERTIFICATE: I John L. Schuller Have conducted a �' �Z� L � V
Schuller, ` � 4
physical survey of this property as shown on this drawing and that the .4 0� Q
improvements situated hereon are within the property lines and no tC�, . %1)40 • ,� 4L, �J
enchroachments exist other than noted. Under no circumstance should/ � •' 49TH •. `�' �
any information on this drawing be used for construction of fences, ' U
structures, improvements, or for establishing boundary lines.
EXCLUSION NOTES: It is the owners responsibility to determine -.• ' : " ................:... .�
� •,JOHN L. SCHULLER.• Q %
the existence of any easements, covenants, or restrictions which �. �,/ •.f
s v •• .
do not appear on the recorded subdivision plat. LS --1.0408 { / ter.• ..Awe •
��, • • , .� • � / 1831 Talkeetna Street
WORK ORDER NUMBER: DATE- sc,�: » E-MAIL � �• _� -1- � � Anchara�e, Alaska 99508
JULY 20, 2022 1 =40' schuiler�k.net � Ar 4'� ,�,
DRAWN BY: CHECKED BY GRID NUMBS: east AGE: �1!4
a� \, ,\'A (907) 227--1455 office
22-082
2082 JLS SW2936 220269 s s� 4419.► (907) 274-4992 f ax
MUNICIPALITY OF ANCHOPA E
-On-;Bite Water & tilwastowater Program
P4 my, 1066.54 4700 Eimare Road
Anchcrage, Alaska 9951-9-6660 Pfd; �9W) 3243-79M Fay (947) 343-7WJ7
N It: Mwnw.rnu ni .rxgo n site
0 n -S ito Wastewater Disposal System Permit
Permit Num ban OSP221226 Effective date
Work Type: SepticTank Upgrade Exoratior Date:
Tax Gude Number: 01$232()1()0()
Sita Legal Address: KNIK HEIGHTS BLK l LT 18 G,2936
Sites Mailinq Address: 13200 SHELBURNE RD, Anchorage
Owner, ANNESI JOHN M& CHERYL L Lot SIm in Sq Ft;
Design Engineer: FIRST WATER CONSULTING Total Bedracnls:
Thia permit is #or the construction of:
0,Cnr
�a
z
� w
impartment
7M(202.2
7ffi =3
23336
❑ disposal Field d Septic Tank ❑ Holdinq Tarek L7 Privy ❑ Privat0 well ❑ Water Storage
All constructlan shall be in aoeardance with:
1, The attached approved design,
2. All requirements specii-ied in AnchoragE) Mcrkipel code Chapters 15-55 and 15,65 and the State of Alaska
Wasleweter disposal Regulations (18AAQ72) and Drinking Water Regulations (16AACM)
3. The wastewater cade requir-es inspec- ions during the Inr�_tallatlon, The engineer shall notify the Development
Services Department per AMC 15,65, Provide notifieafion by calling (907) 343-7004 X24{7).
A, FrOM October 15 to April 15, a subsiu rfaoe soll' absorplion system under construction during freezing weather
shall be either;
a. DpenW and OIosed on the same day, or
b. Covered, saalad, and heated to prevent freezing
Received By: _ Date. -
Issued By: ,-�-.r� Date:
7J6/2022
5
MUNICIPALITY OF ANCHORAGE
Development Services Department Phone: 907-343-7904
On -Site Water & Wastewater Section Fax: 907-343-7997
ON-SITE SEPTICM/ELL PERMIT APPLICATION
Parcel 1. D. 018-232 M © i
Property owner(s) JOHN & CHERLY ANNESI Day phone _
Mailing address 13200 SHELBURNE ROAD, ANCHORAGE, AK 99516
Site address 13200 SHELBURNE ROAD, ANCHORAGE, AK 99516
Legal description (Sub'd., Block & Lot) KNIK HEIGHTS BLOCK I LOT 18
Legal description (Township, Range & Section)
Lot Size 23,336 Sq. Ft. Number of Bedrooms 5
APPLICATION IS FOR:
APPLICATION IS AN:
TYPE OF DWELLING:
(® all that apply)
Absorption Field
❑
Initial ❑
Single Family (SF) 0
(w/wo ADU)
Septic Tank
Q
Upgrade ❑ X
Duplex (D) El
Holding Tank
El
Renewal El
Multiple Dwellings ❑
Privy
❑
(SF and/or D)
Private Well
❑
Water Storage
❑
THIS APPLICATION INCLUDES A WAIVER REQUEST FOR:
Distance:
I certify that the above information is correct. I further certify that this is in accordance with
applicable Municipal Codes.
(Sighature of property owner or authorized agent)
Perm it/Rush - Fees— I-o�--a 5 --- --- Waiver -Fees. ----
Date of Payment: of Payment:
Receipt Number: 119993 Receipt Number:
Permit No. 0S P `Q a 1�) 1Waiver No.
GADevelopment Services\Building Safety\On Site Water and Wastewater\Forms\Client FormsTermit Application.doc
13030 Sues Way, Anchorage, AK 99516
907-350-9566 / firstwaterAK@gmail.com
June 27, 2022
Municipalities of Anchorage
On-Site Water & Wastewater Program
4700 Elmore Road
Anchorage, AK 99507
RE: SEPTIC TANK UPGRADE PERMIT
LEGAL: KNIK HEIGHTS BLOCK I LOT 18
The owner has requested that we obtain a septic permit to upgrade the existing aged steel septic
tank on the above referenced lot. We propose to install a 1500-gallon HDPE tank per the
attached design to serve the existing 5-bedroom residence. The lot and area are served by private
wells. The design will not impact any of the neighboring properties. Please contact us if you
have any questions.
Sincerely,
Curtis Huffman, P.E.
Municipality of Anchorage
On-site Water and Wastewater
REVIEWED FOR CODE COMPLIANCE
OSP221228, Deb Wockenfuss, 07/06/22
Municipality of Anchorage
On-site Water and Wastewater
REVIEWED FOR CODE COMPLIANCE
OSP221228, Deb Wockenfuss, 07/06/22
Municipality of Anchorage
Development Services Department
Building Safety Division =•
j Onsite Water & Wastewater Program, 4700 South Bragaw St.
P.O. Box 196650 Anchorage, AK 99519-6650
www.ci.anchorage.ak.us (907) 343-7904 Page 1 of 3
Onsite Wastewater Disposal System and/or Well Inspection Report
Permit Number. SW020022 PID Number. 018-232-01
Name: KEVIN MOYNOHAN
Wastewater System: ■ New ❑ Upgrade
Address:
8628 EMERALD STREET * ANCHORAGE, AK 99502
ABSORPTION FIELD
Phone: No. of Bedrooms:
(907) 243-0620 5
oD*ep Treneh ■Shallow Trench OB*d t7Nound ClOther
LEGAL DESCRIPTION
sa E`a"° 1.2
Tam ape can "'° 7.772 MAX
Gpon, R
rt
Block: Lot: Subdivision:
Depth to ►IDs boh m frvm 010.W pada
Grew depth bn"th pipe
1 18 KNIK HEIGHTS
6.04 MAX n
1.68 a
Township: Range: Section:
1111 eeded ee- 0I0Yw1 OeK
cro a length;
— — —
SEE DWG n
93 R
WELL: ■ New ❑ Upgrade
cmvw sl s
5
/e.ne.r of snee
1
a.latie b hb enae
—
rL
n
Cb,Mlbatbn "C);
Tobi Depth
Cae,d TO:
181
Total obsorpUnn ,rte
628+
rlpe matelot
D 3034/ F-810
PRIVATE
181 n
rL
so. n
arelr.
Dab lkWd:
stow Mata Lew:
MON:
POOR BOY
low broll ch
5/7-10/2002
ALPINE DRILLING
5 10 02
0 n
TIMI
n.p set At:
Cosine NNaM Men Grum
TANK
15 wu
UNKNOWN rt
2 rL
SEPARATION
DISTANCES
■septic oNoiding OS.T.U. 0Other
To
Septic
Abso tion
Uft
Holding
Mc/Pmob
1&eiuh lua:
ANCHORAGE TANK
CapoMy Ln,ape—
1500
From
Tank
Fi*`�d
Station
Tank
seer utwe
well
1000+
100'+
—
—
250+
STEEL
Nanea 2
Surface water
100'+
100'+
—
—
—
LIFT STATION
Lot Una
5'+
10'+
—
Foundation
50+
10't
—
—
—
an k«el et: et
leen am swz n eu
nn* tbt. aeeukM swp«twn. ,aro,m.d sr:
Curtain Drain
NONE
KNOW
Remarks:
BENCH MARK
I.eosum end D sepuaa:
130TTOM OF TANK
THROUGH ST2
�,nwd o..vue2 89.06 n
ENaIMEERe bEl1L
040
Inspections performed by: AKWWC, INC. Dates: 1st 5/7/2002
*�' 4 ....
2nd 5/8/2002
D
3rd 5/9/20
Development Services Department Approval 5/10/2002
�� J' E 53 es4`F:
Qt-- Ie�wed and approved by: Date: 1" A pz—
�0^�-r fes ,to�
�'
40000
W02002E2R: AS-BUILT DRAWING PARCEL 232°01
NEW
WELL
\ /
/
I
NEW SEP` I
/
pl GALLON SEPf1C
TANK
�
J I
— — FCO
DBL
DBLz
(
ST1 16.880 26.620
ST2 24.670 32.980
DBL1 29.490 36.835
DBL2 32.285 39.485
\
"
C01 62.960 35.840
NEW DRAINRELD
MT162.835 34.680
i NATE s \
CO2 54.640 82.330
\
MT2 53.395 81.305
\
[SEPTIC ARS —
I
DATE:
ppdppp
8/16/2002
O(4 QF d
DRAWN BY:
`�/•• •• 40
ALASKA WATRR & WAS TKR'ATKR
Z.T.G.
�0�
SCALE.
CONSULTANTS, INC.
6001 DFRARR ROAD. SUITE 79 • ANCHORAGE A9 00504 • FNONF ("IM374170 • FAX (007)539-5746
j ^ = 40�
*""' "' "'
D
PREPARED FOR: PHONE NUMBER
PAGE NUMBER:
KEVIN MOYNOHAN (907) 243-0620
2 OF 3
p •,j fre Ga esa.
Q G - 953 : iQ
LEGAL DESCRIPBON:
KNIK HEIGHTS SUBDIVISION; LOT 18, BLOCK I,
�O4�a ''•.•, c4oQ
4�QdPFo fasslonox
040000�p
TYPE OF WORK
NEW WELL AND SEPTIC SYSTEM LOCATION
AS-BUILT DRAWING OF
PERMITNUMBER: AS -BUILT DRAWING PARCEL NUMBER:
SW0
SW020022 018-22 32-01
FINAL GRADE
98.2-99.1
TOP OF TANK AT TOP OF TANK AT
INLET - 93.99 OUTLET " 93.94
/ I I NEW 1500 GALLON I I\-91VERT OF BUNG J SEPTIC TANK
AT INLET - 93.54 INVERT OF SUNG AT
OUTLET - 93.18
UT Co FINAL GRADE
99.30-99.31
/ORIGINAL GRADE
FILTER FABRIC ---,R r� 98.72-99.29
ALASKA NATER R NASTENATER
CONSULTANTS. INC.
6001 DFAAPR ROAD. SMTF M • AN[NORAOF. A8 00504 • PNONF (001)337.6190 • FAX (007)338.37.6
2EPARED FOR: PHONE NUMBER:
KEVIN MOYNOHAN (907) 243-0620
:GAL DESCRIPTION:
KNIK HEIGHTS SUBDIVISION; LOT 18, BLOCK I,
PE OF WORK:
PROFILE AS—BUILT DRAWING OF NEW SEPTIC SYSTEM
INVERT OF PIPE1:1001
BOTTOM
TRENCH - 91.57
DATE: Q0d�0
10/11/2002 o pF
DRAWN BY: v
Z.T.G. a�`P I'•.. ..
1"=40'
E NUMBER:
30F3
®®gym 7®®
orness.
95 :i
e^°
Friday, July 26, 200210:53 AM Kevin & Donna Monaghan 907 243.8104
Municipality of Anchorage
Department of Health and Human Services
825 V Street
P.O. Box 196650 Anchorage, Alaska 99519-6650
Rick Mystrom hopllwww.d.anchorage.skus
Mayor
p.02
Permit Number: #SW swO2OO2 Date of Issue: 2 11-02 Parcel Identification Number: 018-232-01
Date Started: 5-9-02 Date Completed: 5-10-02 Is well located at approved permit location? ® Yes ❑ No
Legal Description: Knik Hohts Block 1 Lot 18
Property Owner Name & Address: Kevin Moynohan
8628 Emeral Street
Ancho a Alaska 99502
Borehole Data:
Depth (ft)
Method of Drilling ® air rotary ❑ cable tool
Soil Type, Thickness & Water Strata
From
To
Casing type: steel
stick-up
0
2
Wall Thickness: .250 inches
organics
silt
gravelly sift
cobb/ygravel
silty cobbly gravel
2
3
7
21
60
3
7
21
60
104
Diameter: ¢ inches Depth: L feet
Liner Type:
Diameter: inches Depth: feet
Casing stickup above ground: 2 feet
Static water level (from ground level): 0 feet
Pumping level:-L�-7 feetafter
silt
104
111
2 hours pumping 15 gpm
gravellysilt
111
135
Recovery Rate: 15 gpm
silty gravel
135
176
Method of Testing:ALI-iff
Well Intake Opening Type:
® Open End ❑ Open Hole
water sand & gravel 176 181
❑ Screened Start feet Stopped feet
❑ Perforations Startfeet Stopped feet
Grout Type: Bentonite eramdes Volume: Lhg
Depth: Start0 feet Stopped : feet
Pump: Intake Depth feet
Pump size hp Brand Name
Well Disinfected Upon Completion? ® Yes [j No
Method of Disinfection: chlorine tablets
Comments:
Well Driller. Alpine Drilling & Enterpllses
PO Box 110496
Anchorage Alaska 99511
Attention: The well driller shall provide a well log to the property owner within 30 days of completion and the property
.• v • •.. • o • • ... n -. w.• •.• w �• n ..• i.• • w • .
MUNICIPALITY OF ANCHORAGE
Development Services Department
On -Site Water 6 Wastewater Program
4700 South Bragaw Street
P.O. Box 196650, Anchorage, AK 99519-6650
(907) 343-7904
45--/11016 Z y ; 3a fIN
�7/%a (, pm
ONSITE WASTEWATER DISPOSAL SYSTEM / WATER SUPPLY PERMIT
Initial
Permit Number: SW020022
Date Issued: Feb 11, 2002
Expiration Date: Feb 11, 2003
Parcel ID: 018-232-01
Legal Description: KNIK HEIGHTS BLK I LT 18
Design Engineer: 0041 AK Water & Wastewater Consultan• Site Address: 013200 SHELBOURNE RD
Owner Name: Kevin Moynohan Lot Size: 23336 SO. FT.
Owner Address: 8628 Emerald St. Total Bedrooms: 5 Permit Bedrooms: 5
Anchorage , AK 99502 -
This permit is for the construction of:
❑✓ Disposal Field ❑✓ Septic Tank ❑ Holding Tank ❑ Privy ❑✓ Private Well ❑ Water Storage
All construction must be in accordance with:
1. The attached approved design.
2. All requirements specified in Anchorage Municipal Code Chapters 15.55 and 15.65 and the State of Alaska
Wastewater Disposal Regulations ( 18AAC72 ) and Drinking Water Regulations ( 18AAC80 ).
3. The engineer must notify DSD at least 2 hours prior to each inspection. Provide notification by calling
(907) 343-7904 ( 24 hours ). ( Not required for a Water Supply Permit only ).
4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather
must be either: A. Open and closed on the same day.
B. Covered, sealed, and heated to prevent freezing.
Received By:
Issued By:
Date: c2 — / 1 —0 a
Date: 0
Municipality of Anchorage
• ", Development Services Department
Building Safety Division
Onsite Water& Wastewater Program
4700 South Bragaw St.
P.O. Box 196650 Anchorage, AK 99519-6650
www.ci.anchorage.ak.us
(907) 343-7904
ON-SITE SEWER/WELL PERMIT APPLICATION
FOR A SINGLE FAMILY DWELLING
Parcel I.D. g'� - O I Permit Number S W 020022
Property owner(s) KEVIN MOYNOHAN Day phone 243-0620
Mailing address (1) 8628 EMERALD STREET * ANCHORAGE. AK
Mailing address (2) Zip Code 99502
Legal description (Lot, Block & Sub'd.) - _ LOT 18, BLOCK 1: KNIK HEIGHTS SUBDIVISION,
Legal description (Section, Township & Range) N/A
Lot Size 23 33 3- Acres/Sq.Ft.
THIS APPLICATION IS FOR:
Number of Bedrooms 5
Sewer Only ❑ Well Only ❑
Sewer and Well 0 Water Storage ❑
Sewer Upgrade ❑
THIS PROPERTY CONTAINS:
Hot Tub ❑ Jacuzzi ❑
Swimming Pool ❑ Water Softening Unit ❑
Therapy Pool ❑
certify that the above information is correct. I further certify that this application is being made for a
Single Family Dwelling and Is in accordance with applicable Municipal codes.
ALASKA WATER do WASTEWATER CONSULTANTS, INC.
Permit FeesWSC0MC, �J
Date of Payment: a` -7 1 OI;L
Receipt Number. J cpg-5
Waiver Fees•
Date of Payment:
Receipt Number.
ALASKA WATER & WASTEWATER
CONSULTANTS, INC.
February 4, 2002
Municipality of Anchorage
Development Services Department
On -Site Water & Wastewater Program
P.O. Box 196650,
Anchorage, Alaska 99519-6650
Ref: Proposed Well Location and Septic System for Lots 18, Block I, Knik Heights Subdivision
To whom it may concern:
The proposed 5 bedroom house will be served by a private well and septic system. Two test
holes were excavated in the area of the proposed septic system. The septic system will be
designed around the 30 foot radius of these test holes. We are proposing that a 1500 gallon septic
tank and a 5 -wide trench type drainfield be installed. Comments regarding the proposed design
are summarized as follows:
1. SOILS: See the attached logs which shows the soil classifications, groundwater monitoring,
and the percolation test results. It is our opinion that due to the overall appearance of the soils, an
application rate of 1.2 gallons/day/fe should be used.
2. TRENCH DESIGN:
a. Percolation Rate: <1 & <1 minutes/inch
b. Allowable Application Rate: 1.2 gallons/day/f1
c. Number ofBedrooms: 5
d. Design Flow: 750+ gallons per day
e. Minimum Absorption Area: 625 f12
f. Total Depth: 8.0 feet (max.)
g. Effective Depth: 2
h. Width: 5.0 feet
i. Minimum Length: 90 feet long
j Effective absorption area = 643 f12
k. Reduction Factor: 0.7
3. SURFACE WATERS: There is no surface water within 100 feet of the proposed septic
system.
4. TOPOGRAPHY: As can be seen on the attached topography site plan, the average
topography of this property is a 1 to 10 percent running from approximately southeast to
6901 Debarr Road, Suite 2B • Anchorage, AK 99504
Ph: (907) 337-6179 • Fax: (907) 338-3246 • Website: akwwc.com
northwest; in short, there are no slope concerns.
We are unaware of any adverse impacts this installation would have on adjacent wells or septic
systems. If you have any questions, please contact us at 337-6179. Thank you for your
assistance.
P.E., M.S.
NOTE. Attached is a site plan drawing, a design drawing, a topography site plan, 2 soils logs,
and a 7 page construction specification letter which are all part of the design package for this
septic system.
6901 Debarr Road, Suite 2B • Anchorage, AK 99504
Ph: (907) 337-6179' Fax: (907) 338-3246' Website: akwwc.com
KNIK HEIGHTS S/D;
LOT 7, BLOCK L
LEYD❑N ROAD
PROPOSED VELL-
1�
I
I � 1
IO
M LT/CAI
0,
PROPOSED SEPTICN,
SYSTEM (SEE DESIGN
--_ PACE 2 OF 2)1_
/ (:TMIC ARLAD
KNIK HEIGHTS S/D;
LOT 0, BLOCK 1,
CSEPTIC ARaD
1
I KNIK HEIGHTS S/D;
1 LOT 9, BLOCK I.
I
PROPOSED 5
KNIK
LOT
KNIK
LOT
`SEPTIC ARS
1
1
McCABE IS/D EAST;
McCABE S/D EAST;
\%LOTT 0. 1
V" I
I
1
(:;&nC AREA
SEPTIC
17 KNIK HEIGHTS S/D;
,1.OT 17, BLOCK L
r 2/4/2002
_ DRAWN BY.
ALASKA WATER & WASTEWATER SCALE* C.J.G.
CONSULTANTS, INC. ...
001 DFRAW ROAD. SIIITF RR • ANCHDRADF. AR 00SM • FHONF (007)311-0170 • FAX (OOTSSA-5740 1 C 100
EPARED FOR PHONE NUMBER: PAGE NUMBER: ��-
KEVIN MOYNOHAN 243-0620 1 OF2 Q.
p
:AL DESCRIPTION:
KNIK HEIGHTS SUBDIVISION; LOT 18, BLOCK I,
IE OF WORK:
SITE PLAN FOR PROPOSED WELL AND SEPTIC SYSTEM LOCATION
a
�\ o
x
\ \ INSTALL FOUNDATION I \ \
CLEANOUT (FCO)
PROPOSED 1500 GALLON
K �- INSTALL DOUBLE
SEPTIC TAN
CLEANOUTS (DBL)
PROPOSED DRAINFIELD. EXCAVATEA
TRENCH THAT IS 5 FEET WIDE 13Y e
FEET DEEP MAXIMUM BY 90 FEET
LONG. ADD 2 FEET OF CLEAN WASHED
SEWER DRAINROCK. INSTALL TRENCH
PARALLEL TO SLOPE CONTOURS.
ALTERNATE SITE \
NOTE: THE WEST EASEMENT do THE
SOUTH LOT LINES SHALL BE I3 II \
FLAGGED BY A REGISTERED LAND
SURVEYOR PRIOR TO CONSTRUCTION.
(ZSEPTIC ARS —
DATE: o�pdOppp
2/4/2002 o OF p
S
ALASKA WATER & WASTEWATERS DRAWN
noC J.G. �p
SCALF-
CONSULTANTS, INC. 1 = 40� Q a"f.... ' "'
OD
6001 DFFA" POGO. SUITF RI • ANCNAGF. AK 995" • PNONF (001)331-6179 • VAX (001)W-3866
PREPARED FOR: PHONE NUMBER: PAGE NUMBER O
KEVIN MOYNOHAN 243-0620 2 OF 2
ff . Gam ss.-
LEGAL DESCRIPTION: Q ° is i
KNIK HEIGHTS SUBDIVISION. LOT 18. BLOCK 1, �04�e�'' •..• cq�v�
TYPE OF WORK: 4°d
DESIGN OF PROPOSED WELL AND SEPTIC SYSTEM LOCATION �440000���
� ~ ...... s,1is SEAL)
e .r Municipality of Anchorage j :4 •TJ/
DEPARTMENT OF HEALTH 8 HUMAN SERVICES ••' '• "'/
825 "L" Street, Anchorage, Alaska 99502-0650
.... ...,
SP
SOILS LOG — PERCOLATION TEST �c :, I N6. 08 LUAMS•'
f �y/ Y ESSIONI�•'
PERFORMED FOR: �✓�N Q Q,/N1'OITIANV III DATE PER
LEGAL DESCRIPTION: LOT Ivy C� L . KMr, )'fry Township, Range, Section:
p EPj11 SLOPE SITE PLAN
.16
(FEETI T (� `
'^. N
2 --
3
4
5
15
16
17
18
19
20
PERFORMED
72-008 (Rev.
S�tnro
Sw%SP - WEu- GmweD
.SAND W/$.µf 6f0uGt
4 cp tbvs�s
'(}ytlx�a -w-t
WAS GROUND WATER %� �O
ENCOUNTERED? N v
s
IF YES, AT WHAT L
DEPTH? p
E
GPU to WAW Atter
mw4winq? DRi Bait 3111 'Ib
VW j�p1- ML
i�.aN.
ALL STATE AND MUNICIPAL
PERCOLATION RATE D I(minutes/inch)PERC HOLE DIAMETER n '�
TEST RUN BETWEEN ...(xSL FT AND —L&— FT
Ai'��1f1-
1/y9d6t%10ERTIFY THAT T IS T ST WAS PERFORMED IN
IN EFFECT ON THIS DATE. DATE:
5
SEAL)
i
Municipality of Anchorage j * 4 0
DEPARTMENT OF HEALTH & HUMAN SERVICES �• 1•'
825 `L" Street, Anchorage, Alaska 99502-0650 /• • 1
SOILS LOG — PERCOLATION TEST '. d NOP WILLIAMS
N0.9608
h 11PR
�ESS10��
PERFORMED FOR: 14.1 oY/vo**v DATE PER
LEGAL DESCRIPTION:' v1T I D� I Xn>tK Township, Range, Section:
SLOPE SITE PLAN
PEPS
�FE2
N
3
4
5
6
.000
7
.III I'
B
9-
to-
12-
13 -
14
10 12 13 14
15
16
17
18
19
MAIM wl SaTy
SA"
We, &MOED
SAND W/yAAi 6MAA1-
t g L a\I&vxS
jTj4xx0* -w-t
—Vey �tvw_ ML
i3.o,l4.
WAS GROUND WATER
ENCOUNTERED?
IF YES, AT WHAT
DEPTH?
No
S
L
O
P
E
Dep to Waw Alur
tomwing7 ORY Owc 11a
20 -{
I� JI PERCOLATION RATED (minutevm�c(f.)�P-ERC HOLE DIAMETER D
TEST RUN BETWEEN FT ANDFT
PERFORMED BY ftL If { kz�_ / U ERTIFY THAT T IST ST WAS PERFORMED IN
ACCORDANC TM ALL STATE AND MUNICIPAL GUIDELIews IN EFFECT ON THIS DATE. OATS
9'
72 -MB (Rev.
MUNICIPALITY OF ANCHORAGE
Development Services Department Phone: 907-343-7904
On -Site Water & Wastewater Section Fax: 907-343-7997
Certificate of On -Site Systems Approval
Parcel I. D. 018-232-01
1. GENERAL INFORMATION
Complete legal description KNIK HEIGHTS BLOCK I LOT 18
Expiration Date: 10-2q-2-2
Location (site address) 13200 SHELBURNE ROAD, ANCHORAE, AK 99516
Current property owner(s) JOHN & CHJEYL ANNESI Day phone
Mailing address 13200 SHELBURNE ROAD, ANCHORAE, AK 99516
Real estate agent
2. TYPE OF DWELLING:
® Single Family (w/wo ADU)
❑ Duplex
❑ Multiple Dwellings (Single Family and/or Duplex)
Day phone
3. NUMBER OF BEDROOMS:
5
4. TYPE OF WATER SUPPLY:
TYPE OF WASTEWATER DISPOSAL:
Private Well
®
Private Septic
Water Storage
❑
Holding Tank
❑
Community Well
❑
Community
❑
Public Water System
❑
Public Sewer
❑
Waiver request for: Distance:
Received by: Date:
COSA to be released to the engineer, unless otherwise requested by the engineer.
COSA Fee $ 5 5 0
Date of Payment 1 002 a
Receipt Number Q�
COSA# OSCo�,a 13 No
Waiver Fee $
Date of Payment
Receipt Number
Waiver #
5. STATEMENT OF INSPECTION BY ENGINEER
As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based
on procedures outlined in the Certificate of On -Site Systems Approval Guidelines for this application, shows that the
on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate for the number of
bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the
Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater
disposal system is (are) in compliance with all applicable Municipal and State codes, ordinances, and regulations in
effect at the time of installation. I acknowledge that On -Site staff may visit the site to verify the information submitted.
Name of Firm FIRST WATER CONSULTING Phone 907-350-9566
Address _13030 SUES WAY, ANCHORAGE, AK 99516
Engineer's Printed Name CURTIS HUFFMAN, PE Date 7117122
Comments: This investigation was completed in compliance with MOA guidelines, regulations,
and best industry practices / methods. The assessment of the condition of the well and septic
applies only to the conditions as of the day tested. The flow and absorption rates may change
due to subsurface conditions that may not be observed from the surface, changes in land use,
local soil characteristics, groundwater levels that may fluctuate during the year, quality of
construction (workmanship & materials), the water usage of the family being served by the
system and maintenance. The operational life of all well and septic systems are subject to
these various and dynamic characteristics and are outside the control of the evaluator of the
well and septic system. Therefore, any estimate of how long a system will function satisfactory
for current or future occupants or guarantee that no unseen encroachments, deficiencies or
discrepancies exist can be given by First Water Consulting & FWcs
6. DSD SIGNATURE _
System #1 Approved for _� bedrooms
System #2 Approved for bedrooms
Disapproved
.........
.... ...�:
r • ' • Curtis Huffman
�6-,, ; CE 128991 .•��`��
.7117/22
OF ss o -
Conditional approval for bedrooms, with the following stipulations:
By: T �' �� Original Certificate Date:
The Municipality of Anchorage Development Services Division (DSD) issues Certificates of On -Site Systems Approval (COSA) based only upon the
representations given in paragraph 5 by an independent professional civil engineer registered in the State of Alaska. The Municipality of Anchorage is
not responsible for errors or omissions in the professional engineer's work.
7. ATTACHMENTS:
COSA Checklist X Nitrate Advisory
Septic System Advisory Arsenic Advisory
Well Flow Advisory Other
Legal Description: KNIK HEIGHTS BLOCK I LOT 18 Parcel ID: 018-232-01
If more than 1 septic system on lot: COSA Checklist # of
A. WELL DATA
® Well log is filed with Onsite (or attached)
Date drilled 5/10/2002
Total depth 181 ft
Cased to 181 ft
® Sanitary seal is functioning correctly
® Wires are properly protected
Casing height (above ground) 18+ in.
Date of flow test for COSA 6/21/2022
Static water level at beginning of test 159 ft.
Comments
B. TANK DATA
Age of tank(s) NA_— NEW TANK years
Tank type/material SEPTIC / HDPE
Measured operating fluid level in septic tank NA
® Standpipes/foundation cleanout per record drawing
Date of pumping NA
D. ABSORPTION FIELD DATA
Structure served by this system
Well production at time of test 4+ pm
Water storage tank volume NA gallons
Well disinfected for coliform test? ❑ Yes ® No
® Coliform bacteria is Negative
Nitrate 4.91 mg/L ❑ Nitrate less than MRL (ND)
Arsenic ug/L ® Arsenic less than MRL (ND)
Collected by NES
Date of Sample 6/21/2022
C. LIFT STATION
❑ Required maintenance completed
Age of lift station _ years
Lift station material
Comments:
Which system tested (date installed) 5/10/2002
Adequacy test date 6/21/2002
® ALL standpipes present per record drawing
Results M Pass For 5 bedrooms
Total measured depth from grade 6.8 ft (max)
Fluid depth prior to test 3 in
Measured depth to pipe invert from grade 5. ft (min)
Water added 750 gal
❑ N/A — pressurized field
® Monitor tubes go to bottom of effective. If not, state
New depth 7 in
depth into effective MOA IR SHOWS 1.68'ED
Elapsed time <1440 min
ED Code -required soil cover over field
Final fluid depth 3 in
❑ System presoaked
Absorption rate 750 gpd
(Required if vacant for greater than 30 days prior to
Any rejuvenation treatment (past 12 months) N
date of test)
Gallons introduced gallons
If yes, enter date
Comments/Deficiencies: WEST MT/CO AT GRADE. MEASUREMENTS SHOW APPROX 1.81ED QFm
E. SEPARATION DISTANCES
From Private Well on Lot to: (Please enter distances if less than required or if community well)
Septic Tank/Lift Station on Lot > 100'
® Yes if No ft
Wells on Adjacent Lots:
Community Sewer Manhole/Cleanout > 100'
® Yes
if No
ft
® Yes
if No ft
Neighboring Tank > 100' ® Yes
if No
ft
Private Sewer/Septic Line > 25' ® Yes
if No ft
Absorption Field on Lot > 100' ® Yes
if No
ft
Holding Tank > 100' ® Yes
if No ft
Neighboring Absorption Fields > 100'
Surface Water > 100'
® Yes
Animal Containment > 50' ® Yes
if No ft
® Yes
if No
ft
Manure/Animal Excreta Storage > 100'®
Community Sewer Main > 75' ®Yes
if No
ft
Yes
if No ft
From Septic/Holding Tank on Lot to: (Please enter distances if less than required)
Building Foundations > 10' ® Yes if No ft Surface Water > 100' ® Yes if No ft
Property Line > 5
® Yes if No ft
Wells on Adjacent Lots:
Absorption Field > 5'
® Yes if No ft
Private Wells >' 100
_ ®Yes if No .
Water Main > 10'
® Yes if No ft
Community Wells > 200' ® Yes if No
Water Service Line > 10'
® Yes if No ft
If septic tank is under driveway comment below
From Absorption Field on Lot to: (Please enter distances if less than required)
Building Foundation > 10'
® Yes
if No
ft
If absorption field is under driveway comment below
Property Line > 10'
® Yes
if No
_ ft
Wells on Adjacent Lots:
Water Main > 10'
® Yes
if No
ft
Private Wells > 100' ® Yes if No ft
Water Service Line > 10'
® Yes
if No
ft
Community Wells > 200' ® Yes if No
Surface Water > 100'
® Yes
if No
ft
F. ENGINEER'S COMMENTS
G. ENGINEER'S CERTIFICATION
1 certify that 1 have determined through field inspections and review
of Municipal records that the above systems are in conformance
with MOA COSA guidelines in effect on this date.
Aq-
.. .... ..........
Curtis Huffman
CE 128991 w �®
s�F-Fo AW
7/22/22, .��f A
PROFESS10NP �
M
ft
Municipality of Anchorage
On -Site Water & Wastewater Program
A (907) 343-7904
r J
CERTIFICATE OF ON-SITE SYSTEMS APPROVAL
VA
Parcel I.D. 018-232-01 Expiration Date: 9-16-113
1. GENERAL INFORMATION
Complete legal description KNIK HEIGHTS: BLOCK I, LOT 18
Location (site address)
Current Property owner(s)
Mailing address
Real Estate Agent
13200 SHELBURNE *ANCHORAGE, AK 99516
CHERYL IMBRIANI Day phone
13200 SHELBURNE *ANCHORAGE AK 99516
227-3497
DARRELL FRIESS Day phone 240-9225
2. TYPE OF DWELL PIG:
0 Single Family (w/wo ADU)
❑ Duplex
❑ Multiple Dwellings (Single Family and/or Duplex)
3. NUMBER OF BEDROOMS: 5
4. TYPE OF W/'.TER SUPPLY:
TYPE OF WASTEWATER DISPOSAL:
IndividuaWell
Individual On-site
0
Individ .l Water Storage
❑
Individual Holding tank
❑
Comn;.mity Class Well
❑
Community On-site
❑
Public Water System
❑
Public Sewer
❑
Received by - •� �_
COSA to be released to the engineer, unless otherwise requested by the engineer.
Date: i
A ,
l h y
COSA Fee $__. -7z W
�V- � Waiver Fee $
Date of Payment` Date of Payment _
Receipt Numt;r�t J� /3►L�'7 Receipt Number
COSA# �Sc,r 3��7d Waiver#
5. STATEMENT OF INSPECTION BY ENGINEER
As certified by my seal affixed hereto and as of the validation date shown below, 1 verify that my f$
investigation, based on procedures outlined in the Certificate of On -Site Systems Approval Guidelines for this application,
shows that the on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate
for the number of bedrooms and type of structure indicated herein. I further verify that based on the
information obtained from the Municipality of Anchorage files and from my investigation and inspection, the
on-site water supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal
and State codes, ordinances, and regulations in effect at the time of installation.
Name of Firm
GARNESS ENGINEERING GROUP, Ltd.
Address 3701 E. TUDOR ROAD, SUITE 101 * ANCHORAGE, AK 99507
Engineer's Printed Name JEFFREY A. GARNESS, P.E.
Engineer's Comments:
In conducting this evaluation, GEG, LtD. attempted to provide a thorough,
conscientious engineering analysis of the system in accordance with ADEC and MOA
DSD Guidelines & Regulations. The reported results described the performance of the
system under the conditions encountered at the time of the test, and separation
distances measured to readily identifiable features. The operational Irfe of all wells and
septic systems depend on the local soils condition, groundwater levels that may
fluctuate during the year, and the water usage of the family being served by the system.
These conditions are outside the control of the evaluator of the system. Satisfactory test
results do not guarantee future performance of the system, nor do they guarantee that
there are no hidden defects or encroachments. GEG, LTD, can therefore not provide
any warranty or future estimate of how long the system will continue to meet the
operational requirements of the ADEC or MOA DSD. The content of this report is for
the sole benefit of the owner listed above. Any reliance upon or use of this report by any
other person or party is not authorized, nor will it confer any legal right whatsoever.
6. DSD SIGNATURE
?Z System #1 Approved for 5— bedrooms.
System #2 Approved for
Disapproved.
Conditional approval for
bedrooms.
337-6179
Date
bedrooms, with the following stipulations:
oN-SITE
WATER AND
WASTEWATER
Original Certificate Date:_
The enicipkf'�ydrA4chorage Develop,emt Services Division (DSD) issues Certificates of On -Site Systems Approval (COSA) based only
upon the represenatations given in paragraph 5 by an independent professional civil engineer registered in the State of Alaska.
The Municipality of Anchorage is not responsible for errors or omissions in the professional engineers work.
7. ATTCHMENTS:
COSA Checklist Nitrate Advisory
Septic System Advisory Arsenic Advisory
Well Flow Advisory Other
(Rev. 111/05)
If more than 1 septic system is on the lot:
COSA Checklist # _of_
Structure served by this system _
Certificate of On -Site Systems Approval Checklist
Legal Description: KNIK HEIGHTS; BLOCK I. LOT 18 Parcel ID: 018-232-01
A. WELL DATA
Well type PRIVATE If A, B, or C provide PWSID# N/A
Date completed 5/10/02 Sanitary seal (Y/N) YES
Total depth 181 ft.
Date of test
Static water level
Cased to 181 ft.
FROM WELL LOG
5/10/02
Well Log (Y/N) YES
Wires properly protected (Y/N) YES
Casing height (above ground) 18+ in.
AT INSPECTION
5/1/13
Well production 15 —9 -P.M. 3.58
9 -P -m.
WATER SAMPLE RESULTS:
Coliform a colonies/100 ml. Nitrate I'L mg./L. Collected by: GEG. Ltd.
Arsenic:JU ug./L. Date of sample: 4/30/13
B. SEPTIC/HOLDING TANK DATA
Tank Type/Material SEPTIC/STEEL
Tank size 1500 gal. Number of Compartments ?
Foundation cleanout (Y/N) YES Depression over tank (Y/N) NO
Date of pumping a `)113 Pumper 1 SG G C ns
C. ABSORPTION FIELD DATA *BELOW EXISTING GRADE
Date installed 5/7/10/02 Soil rating (g.p.d./ftor � 1.2
Length 93 ft. Width 5 ft.
Date installed 5/7-10/02
Cleanouts(Y/N) YES
High water alarm (YIN) N/A
System type SHALLOW TRENCH
Gravel below pipe 1.88 ft.
Total depth *8.12 ft. Eff. absorption area828+ ft2 Monitoring tube YES Depression over field NO
Date of adequacy test 5/1/13 Results (Pass/Fail) PASS For 5 bedrooms
Fluid depth in absorption field before test 0 in. Water added 750 gal. New depth 0 in.
Elapsed Time: 4 min. Final fluid depth 0 in. Absorption rate >= 750+ g.P.d.
Any rejuvenation treatment (past 12 mo.) (Y/N & type) NONE If yes, give date —
D. LIFT STATION
Date installed Size in gallons Manhole/Access (YIN
"Pump on" level at in. "Pump ofP' level High water alarm level at in.
Cycles tested Meets alarm & circuit requirements?
E. SEPARATION DISTANCES
SEPARATION DISTANCES FROM WELL ON LOT TO:
Septic tank/lift station on lot 100'+ On adjacent lots 100'+
Absorption field on lot 100 + On adjacent lots 100'+
Public sewer main N/A
Sewer /septic service line 25'+
Animal containment areas 50'+
Public sewer manhole/cleanout N/A
Holding tank N/A
Manure/animal excrete storage areas 100'+
SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK ON LOT TO:
Building foundation 5'+ Property line 5'+ Absorption field 5'+
Water main N/A Water service line 10'+ Surface water 100'+
Wells on adjacent lots 100'+
SEPARATION DISTANCE FROM ABSORPTION FIELD ON LOT TO:
Property line 10'+ Building foundation 10'+ Water main N/A
Water service line 10'+ Surface water 100'+ Driveway, parking/vehicle storage 10'+
Curtain drain NONE KNOWN Wells on adjacent lots 100'+
F. COMMENTS
G. ENGINEER'S CERTIFICATION
I certify that I have determined through field inspections and
review of Municipal records that the above systems are in
conformance with MOA COSH guidelines in effect on this
date.
Engineer's Printed Name JEFFREY A. GARNESS
Date 15-) Is -h?
(Rev. 11105)
Municipality of Anchorage •-
Development Services Department C�' `
Building Safety Division
• _ i On -Site Water 8 Wastewater Program
4700 South Bragaw St.
P.O. Box 196650 Anchorage, AK 99519-6650
www.ci.anchorage.ak.us
(907)343-7904
CERTIFICATE OF HEALTH AUTHORITY APPROVAL
FOR A SINGLE FAMILY DWELLING
((�
Parcell.D. 018-232-01 HAA# tt
1. GENERAL INFORMATION T
Expiration Date: 3 8 O
Complete legal description KNIK
HEIGHTS SUBDMSION•
LOT 18
BLOCK r
Individual On-site
0
❑
Location (site address or directions)
13200 SHELBURNE
ROAD *
ANCHORAGE AK 99516
Community Class Well
❑
Community On-site
Current Property owner(s)
Mailing address
Lending agency
Mailing address
Real Estate Agent
Mailing address
KEVIN MOYNOHAN Day phone (907) 243-0620
8628 EMERALD STREET * ANCHORAGE AK 99502
Day phone
NIEL THOMAS W/COLDWELL BANKER Day phone (907) 265-9106
2525 "C" SREET • ANCHORAGE, AK 99503
Unless otherwise requested, HAA will be held by DSD for pickup.
2. NUMBER OF BEDROOMS: 5
3. TYPE OF WATER SUPPLY:
TYPE OF WASTEWATER DISPOSAL:
Individual Well
Individual On-site
0
❑
Individual Water Storage
❑
Individual Holding tank
❑
Community Class Well
❑
Community On-site
❑
Public Water System
❑
Public Sewer
The Municipality of Anchorage Development Services Department (DSD) Issues Certificates of Health Authority
Approval (HAA) based only upon the representations given in paragraph 4 by an Independent professional civil
engineer registered in the Stale of Alaska. Certificates of Health Authority Approval are required for the transfer
of title (except between spouses) for properties served by a single-family on-site wastewater disposal and/or
water supply system. DSD also Issues HAAs upon request to homeowners. Certificates of Health Authority
Approval are valid for 90 days from the date of issue for properties served by a private or Class C well and may
j be reissued with new water samples. (Certificates may be reissued for a period of up to one year with valid
water samples.) Certificates are valid for one year for properties served by Class A or B wells or a public water
system. The Municipality of Anchorage Is not responsible for errors or omissions in the professional engineer's
work.
4. STATEMENT OF INSPECTION BY ENGINEER
As certified by my seal affixed hereto and as of the validation date shown below, I verify that my
investigation, based on procedures outlined in the Health Authority Approval Guidelines for this application,
shows that the on -situ water supply and/or wastewater disposal system is(are) safe, functional and adequate
for the number of bedrooms and type of structure Indicated herein. /further verify that based on the
information obtained from the Municipality of Anchorage (les and from my investigation and inspection, the
on-site water supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal
and State codes, ordinances, and regulations in effect at the time of installation.
Name of Finn ALASKA WATER & WASTEWATER CONSULTANTS, INC.
Address 3701 E. TUDOR ROAD, SURE 101 • ANCHORAGE, AK 99507
Engineer's Printed Name JEFFREY A. GARNESS, P.E.
Engineer's Comments:
In conducting this evaluation, AKWWC, Inc. attempted to provide a thorough,
conscientious engineering analysis of the system In accordance with ADEC and MOA
DSD Guidelines & Regulations. The reported results described the performance of the
system under the conditions encountered at the time of the test, and separation
distances measured to readily Identifiable features. The operational life of all wells and
septic systems depend on the local soils condition, groundwaterlevels that may
fluctuate during the year, and the water usage of the family being served by the system.
These conditions are outside the control of the evaluator of the system. Satisfactory test
results do not guarantee future performance of the system, nor do they guarantee that
there are no hidden defects or encroachments. AKW WC, Inc. can therefore not provide
any warranty or future estimate of how long the system will continue to meet the
operational requirements of the ADEC or MOA DSD. The content of this report is for
the sole benefit of the owner listed above. Any reliance upon or use of this report by any
other person or party is not authorized, nor will It confer any legal right whatsoever.
5. DSD SIGNATURE
y Approved for '9� bedrooms.
Disapproved.
Phone 337-6179
Date IZ /I -Z' 03
Conditional approval for bedrooms, with the fllowino stipulations:
VINVOrKAM
Attachments: �'.�� ••.
HAA Checklist ✓ Manitenance Agreements JJJJi
Septic System Advisory Supplemental Engineer's Reort
Well Flow Advisory Other
By: ? /' � �61L� Original Certificate Date: 02— R fl 3
(Rev. 12101)
Municipality of Anchorage
Development Services Department
Building Safety Division ...
Onsite Water b Wastewater Program
4700 South Bregsw St.
P.O. Box 198650 Anchorage. AK 995196650
www.d.snchorage.sk.us
(907)343-7904
HEALTH AUTHORITY APPROVAL CHECKLIST
Legal Description: KNIK HEIGHTS SUBDIVISION,• LOT 18, BLOCK I Parcel ID: 018-232-01
A. WELL DATA
Well" PWAn If A, B, or C provide PWSID# N/A Well Log (YM) YES
Data completed 5Z10/2002 Sanitary seal (YIN) YES Wires property protected (Y/N) YES
Total depth 181 ft. Cased to 181 ft.
FROM WELL LOG
Date of test 5/10/2002
Static water level D ft.
Well production 15 g.p.m.
WATER SAMPLE RESULTS:
Coliform 0 colonies/100 ml. Nitrate 1.47 mg./L.
Casing height (above ground) 18+ in.
AT INSPECTION
Other bacteria 4 colonies1100 ml.
Arsenic: N/A mgJL. Date of sample: 11/26/200 Collected by: AKWWC. INC,
12/5/2003
B. SEPTICIHOLDING TANK DATA
Tank Type/Material STEEL Date installed 5/7-10/2002
Tank size 1500 gal. Number of Compartments E Cleanouts (YIN) Y
ES
Foundation cleanout (YIN) YES Depression over tank (YIN) NO High water alarm (YIN) N/A
Date of pumping NEW Pumper —
C. ABSORPTION FIELD DATA
Date installed 17-10/2002 Soil rating .p.d r ft%bdrm) 11=2 System type 5—WIDE TRENCH
Length 93 ft. Width 5 ft. Gravel below pipe 1.68 ft.
Total depth `7.7 ft. Ell. absorption area 628+ R° Monitoring tube YES Depression over field NO
Date of adequacy test NEW Results (Pass/Fail) — For E bedrooms
Fluid depth in absorption field before test = in. Water added =go'. New depth =in.
Elapsed Time: = min. Final fluid depth = in. Absorption rate >_ — g•p•d•
Any rejuvenation treatment (past 12 mo.) (Y/N 6 type) — If yes, give date
D. LIFT STATION
Date installed S¢e in gallons
"Pump on" level at _in.
E. SEPARATION DISTANCES
High water alarm level at in.
Cycles tested Meets alarm & circuit requirements?
SEPARATION DISTANCES FROM WELL ON LOT TO:
Septic tank/lift station on lot 100'+
Absorption field on lot 100'+
Public sewer main N/A
Sewer /septic service line 25'+
On adjacent kits 100'+
On adjacent lots 100'+
Public sewer manhole/deanout _ N/A
Holding tank N/A
SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK ON LOT TO:
Building foundation 5'+ Property line 5'+ Absorption field 5'+
Water main _ N/A Water service line 10'+ Surface water 100'+
Wells on adjacent lots 100'+
SEPARATION DISTANCE FROM ABSORPTION FIELD ON LOT TO:
Property line 10'+ Building foundation 10'+ Water main N/A
Water service line 10'+ Surface water 100'+ Driveway. parking/vehide storage 10'+
Curtain drain NONE KNOWN Wells on adjacent bis 100'+
F. COMMENTS
G. ENGINEER'S CERTIFICATION
I ceRlfy that I have determined through field inspections and
review of Municipal records that the above systems are in . . . . .• • • • . . • •
conformance with MOA HAA guidelines in effect on this date.
Engineer's Printed Name JEFFREY A GAR a y Go S. `
f °qA . E 7953 .• 1E
Date _ `L l�. OZ r•oe'. ..•��
HAA Fee $ 3 W. °' // Waiver Fee $ _
Date of Payment 1 i/ti kir Date of Payment
Receipt Number Receipt Number,
(Pe. 12101)
Friday, November 21, 2003 3:06 PM Kevin & Donna Monaghan 907 243-8104
1 11=30'
PLAT NO. P -452B '
KNIK HEIGHTS SUBDIVISION
LOT 18, BLOCK 1
27,285 S.P.
0
8
c
as wiown an Ws record Orawtng
(ee-bullt) compras WRh Me 21, AMG
er.1' I AC ad . r
FMAL. STRUCTURE AS–BUILT
AS—BU I L T
1 HEnESY CERHFY THAT I NAVE suwErm THE
PROPCNTY DEPICTED ABOVE AND THAT NO
GASTALDI LAND SURVEYING
D CRO04NMENM COW EXCEPT AS RIDIWED.
JEFF A GASTAD4 RLS.
R n THE RLSPONSIBAJTY OF THE OWNER TO
4725 WEST SBM AVENUE
DETEAIYNE THE EXISTENCE OF ANY EASEMENTS,
ANCHORAGE ALASKA OiSO2
COVENANTS OR RESTRICTIONS WLC14 DO NOT
PHONE 448-5454
APPEAR ON THE RECORDED SUBON6R)N PLAT,
UNDER NO CIRCUMSTANCES SHOULD ANY DATA
GRID
DATE
HEREON BE USED FOR CONSTRUCnON OR FOR
rix
t2/\2/2002
ESTABLI.4WIEI BOUNDARY OR FENCE LINES.
ANCHOR"." RECORDING OISTRICf, ALASKA
►8
JOB N 0.
NOTE: NO CORNERS SET THIS DATE.
p.02