Loading...
HomeMy WebLinkAboutSOUTH HILLS BLK 2 LT 1South Hills Block 2 Lot 1 #017-063-06 Expired Permit Not Eligible for COSA MUNICIPALITY OF ANCHORAGE Development Services Department On -Site Water 8 Wastewater Program 4700 South Bragaw Street P.O. Box 196650, Anchorage, AK 99519-6650 (907) 343-7904 ON-SITE WASTEWATER DISPOSAL SYSTEM PERMIT Renewal Date Issued: Aug 29, 2008 Expiration Date: Aug 29, 2009 Permit Number: SWO80182 Parcel ID: 017-063-06 Legal Description: SOUTH HILLS BLK 2 LT 1 Design Engineer: 0019 FLATTOP TECHNICAL SERVICES Site Address: 007340 HILLSIDE WAY Owner Name: BILL YEAGLE Lot Size: 54801 SO. FT. Owner Address: 7340 HILLSIDE WAY Total Bedrooms: 3 Permit Bedrooms: 3 ANCHORAGE. AK 99516-3741 This permit is for the construction of: ❑ Disposal Field ❑ Septic Tank Holding Tank ❑ Privy ❑ Private Well ❑ Water Storage All construction must be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal Code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations ( 18AAC72 ) and Drinking Water Regulations ( 18AAC80 ). 3. The engineer must notify DSD at least 2 hours prior to each inspection. Provide notification by calling (907) 343-7904 ( 24 hours). ( Not required for a Water Supply Permit only). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must be either: A. Open and closed on the same day. B. Covered, sealed, and heated to prevent freezing. Received By: ��� Vjlel"� Date: �.. .. • is Cw e Municipality of Anchorage Development Services Department Building Safety Division'4 On -Site Water and Wastewater Program s r 4700 Bragaw Street P.O. Box 196650 Anchorage, AK 99519-6650 www.muni.org/onsite (907) 343-7904 ON-SITE SEPTICMELL PERMIT APPLICATION FOR A SINGLE FAMILY DWELLING Parcel I.D. I - ob3'Q�o Propertyowner(s) aN& tE l , OM 0 Dayphone 3r -i5- 105 Mailing address 1 I Zip Code Site address3�iD i�I L(�SL/Lf. �,I )al A I ' I ,p,( A Zip Code 6161J) (p Legal description (Sub'd, Block & Lot) Legal description (Township, Section & Range) tbOlh b101 -S 755 L-1 Lot Size 54, 2 b Sq. Ft. Number of Bedrooms sn� 3 THIS APPLICATION IS FOR (®all that apply) Absorption Field ❑ Septic Tank El Holding Tank ❑ Privy Private Well ❑ Water Storage ❑ THIS APPLICATION IS AN: Initial ❑ Upgrade ❑ Renewal ❑ I certify that the above information is correct. I further certify that this application is being made for a Single Family Dwelling and is in accordance with applicable Municipal Codes. of property owner or authorized agent) Permit/Rush Fees:— Waiver Fees: Date of Payment: ff/ov/be Date of Payment: Receipt Number. 6655 17iG Receipt Number: (Rev. 11/05) MUNICIPALITY OF ANCHOR4GE Development Services Department Onsite Water 8 Wastewater Program 4700 South Bragaw Street P.O. Box 196650, Anchorage, AK 99519-6650 (907) 343-7904 ONSITE WASTEWATER DISPOSAL SYSTEM PERMIT Upgrade Permit Number: SW070101 Legal Description: SOUTH HILLS BLK 2 LT 1 Design Engineer: 0019 FLATTOP TECHNICAL SERVICES Owner Name: BILL YEAGLE Owner Address: 7340 HILLSIDE WAY ANCHORAGE, AK 99516-3741 Date Issued: Jun 12, 2007 Expiration Date: Jun 11, 2008 Parcel ID: 017-063-06 Site Address: 007340 HILLSIDE WAY Lot Size: 54801 SO. FT. Total Bedrooms: 3 Permit Bedrooms: 3 This permit Is for the construction of. ❑ Disposal Field E] Septic Tank Holding Tank E] Privy E] Private Well ❑ Water Storage All construction must be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal Code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations ( 18AAC72 ) and Drinking Water Regulations (18AAC80 ). 3. The engineer must notify DSD at least 2 hours prior to each inspection. Provide notification by calling (907) 343-7904 ( 24 hours ). ( Not required for a Water Supply Permit only ). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must be either: A. Open and closed on the same day. B. Covered, sealed, and heated to prevent freezing. Received By. Date: 6611 j�0] Issued By:r� Date: Z (i Municipality of Anchorage • Development Services Department °'h Building Safety Division ,�• ' a_ On -Site Water and Wastewater Program ` 4700 Bragaw Street P.O. Box 196650 Anchorage, AK 99519-6650 www.muni.org/onsite (907)343-7904 ON-SITE SEPTIC/WELL PERMIT APPLICATION FOR A SINGLE FAMILY DWELLING Parcel I.D. OI 7 - OF? -o,,- Property Or Property owner(s) 13 / lr t6 Y t Day phone 2 TO -s-ll Mailing address 7?'/0 lf.1/t.ai ui�,Ant�•� Zip Code 9 -9s - Site address e"I . of Zip Code Legal description (Sub'd, Block & Lot) lo -A1. e/ock 2 /y.i/, S1 Legal description (Township, Section & Range) Lot Size 5U, go I Sq. Ft. THIS APPLICATION IS FOR (®all that apply) Absorption Field Septic Tank 21 Holding Tank ❑ Privy ❑ Private Well ❑ Water Storage ❑ Number of Bedrooms THIS APPLICATION IS AN: Initial ❑ Upgrade Renewal ❑ I certify that the above information is correct. I further certify that this application is being made for a Single Family Dwelling and is in accordance with applicable Municipal Codes. (Signature of property owner or authorized agent) PermiURSa ush Fees: �i6o Date of Payment: Receipt Number: q qz& (Rev. 11/05) Waiver Fees: Lor 4.n,, wt.rra. I7S Date of Payment: 5 k'to Receipt Number. 47-0-7 FLATTOP TEGHN�CAL SERVICES. a.1 /•5 +. v.:i.; «!r.r'V.+.-..l.t�,vr.......,,ti �w\, \`ate _ -. - CIVIL & ENVIRONMENTAL ENGINEERING ENERGY CONSERVAT104 6 ANALYSIS TED MOORE, P.E. PHJFAX: (907)345-1355 14530 ECHO CANYON ROAD E -Mail: tgmoore@gei.net lune 11, 2007 ANCHORAGE, AK 99516 M.O.A. DSD P.O. Box 19-6650 Anchorage, AK 99519 Dear Sirs: The purpose of this letter is to provide the required design narrative in support of our application for a permit to install a 4000 -gallon holding tank of Lot 1, Block 2 South I fills S/D. This regt:est is a substitution for the previously submitted design for a conventional soil absorption system. That design was determined to be infeasible after changed soil moisture conditions were detected late in breakup, causing the test hole and proposed soil absorption trench to be subject to s:asonal flooding. After the late -breakup groundwater problem was discovered, we dug a second test hole; (2A) at the location shown on the site plan as well as a third shallow test hole near the southeast corner of the lot. Each of these also encountered seasonal groundwater at the interface between the shallow peat layer and the underlying silt stratum that overlies the originally proposed soil absorption stratum. The proposed holding tank will be located less than 100 feet from the roadside ditch along the south side of Hillside way. As of June 7 the seasonal runoff carried by that ditch had ceased b) flow, leading me to understand that the ditch would not be classified as surface water requiring a 100 -foot separation from the holding tank. The original design included a request for separation distance waiver from the north lot line. This request is no longer applicable, so I am requesting a refund of the $175 paid for the waiv:r. The proposed project will have no significant impact on present or future water supply and wastewater disposal systems serving adjacent properties, nor in my opinion will it have any significant impact on reserved space -surface and subsurface, or on drainage. Please give me a call at 345-1355 if you have any questions on this submittal. Sincerely, Ted Moore, P.E. LOT 1, BLOCK 1 SOUTH HILLS &D _ — — HILLSIDE WAY — / \� T.H. #2—T.H. o #2A o \I ; ERC TESTS INSTALL 4000 -GAL SEPTIC . AREA \ ° HOLDING TANK LOT 2. BLOCK 2 62`1e-1� 10% o \ _•T.H. S FAT/c" #1 'T I U) ' DIVE Z ., Z \; O 0° W LL WELL ' � � R=100' \ w T- ROPOSED \ 0 R = 100' i WELL) 3 BDRM _ HOUSE HSE ✓ 1', EXISTING TRAILER &LEAN-TO w TO BE DEMOLISHED AFTER w LL " NEW HOUSE IS CONSTRUCTED z i LOT 1, BLOCK 2 w SOUTH HILLS S/D w L T.H. F ---------' #3 ` o - 0 --- - ' ----------� ; ♦•_•q e��..� • ' LOT 1, BLOCK 2, SOUTH HILLS SID i *fi,L. 49 m • HOLDING TANK INSTALLATION ... « ........:.:....:.:'I/ SITE PLAN --- 0.0••• THEODORE F. FLATTOP TECINICAL SERVICES p TKECE . 58IOORE / 14530 ECHO CANYON ROAD 1 INCH = B FEET $. CIRAWN BY' 7FM •• CE - 3589 ANCHORAGE, ALASKA 99516 REV. JUNE 2007 ,1 Pro /e as%0 NOTE: THIS IS NOT A SURVEYED PU%T. `��` ALL LOCATIONS SHOWN ARE APPROMMATP 4" DIA. D-3034 WASTE LINE -- FROM HOUSE 4" WASTE LINI FROM HOUSE 6" DIA. INSTALL ALARM HERE PLAN VIEW SCALE: 1" = 10' 4LLON . wLVI1vV IMNN W. 5' SOIL COVER FINAL GRADE 5' MIN SOIL_ OVER TANK 3 1 6" PUMPOUT r I `\—ORIGINAL_ 4"C.O. I 4"ALARM/ GROUND ACCESS ---------------- -�- "Of A *t NEW 4000 GALLON HOLDING TANK t =�� 491H iav ; 6,3 r ............ P " : THEODORE F. IdOORE j- 17.2 ry, y;�•,� CE -3589 PROFILE VIEW LOT 1, BLOCK 2, SOUTH fi1LI.S S/D SCALE' 1" = 5' HOLDING TANK INSTALLATION • PLAN AND CROSS-SECTION FLATTOPTECINICALSERVICES SCALE:ASSIIOWN 14570 ECI IO CANYON ROAD DRA WN IiY: Trh I ANCI IORAGE. AK, 99516 MAY. 2007 Flattop 7ec&nicaCSenices 14S30 Echo Street, Anclromge, AX 99516 Tfwne (907) 34S-13SS Lot 1, Block 2, South hills S/D 7340 Hillside Way Holding tank installation Specifications 1.0 General: 1.1 The scope of the project consists of abandonment of an existing septic tank End soil absorption system and installation of a 4000 -gallon holding tank with a high-level alarm system. 1.2 Construction shall be as depicted on the approved site plan and design drawings.:Nlinor deviations from these drawings may be allowed or required by the engineer conducting the in.-pections. All construction procedures and material specifications shall conform to Municipal and State requirements. All separation distances shall be in conformance with Municipal requirements, unless specifically waived. 1.3 The contractor shall be responsible to obtain any necessary utility locates, and to work around any buried utilities. 1.4 The contractor shall provide adequate cover material and rough grading over all system components to ensure that proper drainage is achieved after settlement and that there are no residual depressions. Insofar as possible the contractor shall minimize damage to trees and existing lawn areas. 1.5 Unless specifically agreed otherwise, the homeowner shall be responsible for finish grading after the soil is compacted, as well as placement of topsoil and reseeding all areas disturb:d b,, the construction. 2.0 holding Tank: 2.1 The existing poorly documented septic tank and soil absorption system components must tic properly abandoned by thoroughly pumping, removing the tops and backfilling with soil or concrete. 2.2 The new 4000 -gallon Municipally approved holding tank shall be installed in the approximate location shown on the site plan. The tank shall be set level on undisturbed soil and buried a minimum of 5'feet below final ground surface to prevent flotation. 2.3 All pipe connections to the tank shall be equipped with waterproof mechanical couplings. Tlie waste line from the residence to the septic tank shall have a minimum slope of 1/4"' per foot. 2.4 The holding tank shall be equipped with a low voltage, high level float that triggers an approved visible and audible alarm mounted inside the residence. The float shall be positioned to trigger the alarm when the fluid depth is approximately 57 inches above the bottom of tte tank, thereby leaving 600-800 gallons of capacity remaining in the tank at the time the alarm first sounds. 4.0 Inspections: 4.1 A total of 3 engineering inspections will be required during the course of the proj,:ct: (1) initial stakeout with the contractor to establish the location of the system and to discuss lite phuis, specifications and construction procedures, (2) after the tank has been set level in the excavatian and the piping connected and alarm installed, but prior to backfill, and (3) after final backfill and grading is complete. 4.2 The installer shall coordinate the timing of the inspections with the engineer sufficiently tar in advance to ensure the availability of the engineer. GAAB-HCI - GER ANCHORAGE AREA BOR U�TARTMENT OF ENVIRONMENTAL QUAL 3500 TUDOR ROAD ANCHORAGE, ALASKA 99507 279-8686 INSPECTION REPORT ON-SITE SEWAGE DISPOSAL SYSTEM Z?-? - MAILING G4'7t/ /Gf� ADDRE S✓� 10 j�-5'-,'—PHONE✓52 NAME , LOCATION /�r/0��1/L966'/� 4,e, ' LEGAL DESCRIPTION,Go SEPTIC TANK: NUMBER OF DISTANCE FROM WELL MATERIALCOMPARTMENTS ��yr � �� ST•�E- Z ��%!1j !�� ��'`'/G'�li�_LIG7 UID LIQUID CAPACITY Zd l2O GALLONS. INSIDE LENGTH INSIDE WIDTH �- DEPTH � SEEPAGE SYSTEM: SEEPAGE PIT: i NUMBER OF PITS OUTSIDE DIAMETER J OR WIDTH LENGTH 2� DEPTH LINING MATERIAL... DISTANCE FROM WELL � BUILDING FOUNDATION�U ?ter i NEAREST LOT LINE __?Z/ TOTAL EFFECTIVE ABSORPTION AREA (WALL AREA) 44f�� SO. FT. TILE DRAIN FIELD: 1T/11-3;7 DISTANCE FROM NUMBER OF DEPTH: TOP OF TILE TO FINISH GRADE NEAREST LOT TOTAL LENGTH OF LINES_ ISTANCE BETWEEN LINES \ TRENCH WIDTH IN. TOTAL EFFECTIVE FT. LENGTH OF EACH LINE OF FILTER MATERIAL BENEATH ABOVE TILE WELL: DISTANCE FROM i WATER TYPEUU�/ DEPTH ��� ,BUILDING FOUNDATION. X f SAMPLE NEAREST SEPTIC TANK ���� SEEPAGE LOT LINE �p 17– SEWER LINE_, TANK SYSTEM DISTANCES: DIAGRAM OF SYSTEM NEAREST ,T.,EM il�llit/� DATE �� �I GRE ER ANCHORAGE AREA BOUGH I�( DEPARTMENT OF ENVIRONMENTAL QUALITY PERMIT NO. h 3500 TUDOR ROAD POUCH 6.650 ANCHORAGE, ALASKA 99502 TELEPHONE 279-8686 r SEWAGEDISPOSALSYSTEM - APPLICATION ANDc PERMIT J3✓` % j NAME OF APPLICANT �L, N r i � NI CIS MAILING ADDRESS u -®OB V 'S4 `� PHONKI E°l�/ INSTALLATION LOCATION LEGAL DESCRIPTION INSTALLATION OF: SEPTIC TANK /TT/��pp��{{gg'' SEEPAGE PIT //n , DRAIN FIELD , OTHER , IIfL' YPE AND SIZE OF FACILITY TO BE SERVED • dwa& 041144 / aml 'FINANCED THROUGH JB�r TO BE INSTALLED BY SOIL TEST RESULTS pe"'J1I_� NOTE: THIS PERMIT IS NOT VALID WITHOUT SOIL TEST COMPLETION DATE ANTICIPATED FINAL INSPECTION: 24 HOUR NOTICE REQUIRED. BACKFILLING OF ANY SYSTEM WITHOUT FINAL INSPECTION BY THE HEALTH DEPARTMENT AUTHORITY WILL BE SUBJECT TO PROSECUTION. SEPTIC TANK SIZE /'OOd TYPE S ✓ —�'C '-- SEEPAGE AREA SIZE MINIMUM DISTANCES, REQUIREMENTS FOUNDATION TO SEPTIC TANK j/ FOUNDATION TO SEEPAGE PIT '2U DRAIN FIELD SEPTIC TANK TO SEEPAGE PIT WALL SEPTIC TANK SEEPAGE PITS DRAIN FIELD TO NEAREST LOT LINE. ! WELL TO SEPTIC TANK `� O SEEPAGE PIT DRAIN FIELD ALSO CONSIDER AREA WELLS. / / r WATER MAIN TO SEPTIC TANK /L� SEEPAGE PIT DRAIN FIELD �/ SEPTIC TAN K,•2".l_, SEEPAGE PIT va DRAIN FIELD , TO RIVER, LAKE, STREAM. CAST IRON INTO AND OUT OF SEPTIC TANK AND INTO CRIB CROSSING GAP OF EXCAVATION 5 FEET INTO UNDISTURBED SOIL. 4 INCH DIAMETER CAST IRON SIPHON PIPES ON SEPTIC TANK AND SEEPAGE PIT FITTED WITH AIRTIGHT R�kOVABLE CAPS. GRAVEL BACKFILL CONFORM TO BOROUGH REGULATIONS REGARDING INSTALLATION. HEAL H AUTHORITY OR LICENSED DESIGNER TYPE Wtlf z'Z- DIAGRAM OF SYSTEM I CERTIFY THAT 1 AM FAMILIAR WITH THE REQUIREMENTS OF GREATER ANCHORAGE AREA BOROUGH ORDINANCE NO. 2868 AND T THE ABOVE DESCRIBED SYSTEM IS IN ACCORDANCE WITH SAID CODE, DATE/�/�/ APPLICANT'S SIGNATURE/��+ �✓b �, Re rT AP CHUw; _';,n ?g0I CASE _+ a Performed FOxb Glen Pinnick Date Performed 8/31/71 Leja. Dc script ?i,h "1 `"y South Hills— This f'crm R - epo ts a: Ste-7sX - ......a.......r....�__ est Depth -2ee.t "ci Cha e=,:.sting Location Sketch Dark gray clayey silt 2 --; organic 0 Gray silt and sand os) with sand seams (SP) Was Ground dater Encountered?--n.— if ncountered?rt—no if Yes, At Wat Dep*h. Reading ate Gross :ime Ne =:;e Depth rcola U., I ate To Nln .Net Drop. Fropos; fMcd inst.ern Ena;e X Drain I.ieid Depth Of inlet eyc o Bottom of Pit _. '"renc?i COMMENTS: 245 sauare feet of drain area is required per bedroom. Test Performed Hv: R. E. Carlisle Data Certified By: National Testing Services, Inc. Date: - DL Form 241 8/66 Drilling Co • WATER WELL DRILLER LOG DO NOT FILL IN AAM & Drilling, hw: ANCHORAGE, ALASKA 99503 90/ .4` Z Well No. Permit No. Certificate No. Area Well Owner �(J / /l//�/C/� �Lv y �i ��r Use of Well Location (address of: Township, Range, Section,—known; or distance main road z�/" /Zf'—g )r r�1�k '& Size of casing n Depth of Hole 3— feet Cased to —l;6 feet Static water 1@vel ft. (wave) (below) land surface. Finish of well (check one) open end ( -�E ); Screen ( }; Perforated( ). Describe screen or perforation Well pumping test at '9-3 gallons per (how) of drawdown from static level. Sor_�_hours Was casing collar sealed with cement grout WELL LOG Depth in feet from Give details of formations penetrated, size of material, color, ground surface and hardness. ,� 0 To 4 )/-T/ Olv"fylGS 4 TO 5 4x ; Cor!�- 7— f _ TO TO TO TO TO- M�}.pC14A81 -Ev7� O O EAS' iE lON TO ENVIRON TO TO " TO TO TO TO TO t, f '•.. MUNICIPALITY OF ANCHORAGE DIVISION OF ENVIRONMENTAL HEALTH DEPARTMENT OF HEALTH AND ENVIRONMENTAL PROTECTION APPLICATION FOR HEALTH AUTHORITY APPROVAL CERTIFICATE 51 1. General Information Application Date 02 O (a) Legal Description (include lot, block, subdivision, section, township, range) _Gt I Rk 2 SO -44% Fulls Location (address or directions) $W CQMNUO�OL A / 'Il5(czQ wA,! C 1(1F1L1 LAn/t (b) Applicants Name_Kcj4h4 J UjjjCC Telephone - Home7"-1"Business AppkicanlPj^Address_ 1�Q . 6" `fl% -Ig 4achcA4$e #4 (c) Applicant 391check one) Lending In ; Owner#�b� ; Buyer 'p Other [:�::j (explain); _ (d) Lending Institution Telephone Address (e) Real Estate Co. 6 Agent Address Telephone (f) Mail the HAA to the following address: 2. Type of Residence Single -Family D;Z Multi -Family Other (describe) Number of Bedrooms ° I 3. Water Supply Individual Well Community Q Public = Note: If community well system, must have written confirmation from the State Department of Environmental Conservation attesting to the legality and status. 4. Sewage Disposal Onsite 5� Public Community E:�j Holding Tank Note: If community well system, must have written confirmation from the State Department of Environmental Conservation attesting to the legality and status. [Page 1 of 21 5. Engineering Firm Providing Inspections, Tests, File Search Data and Information As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation of this Health Authority Approval shows that the on-site water supply and/or wastewater disposal system is safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that, based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the or -site water supply and/or wastewater disposal system is in compliance with all Municipal and State codes, ordinances, and regula- tions in effect on the date of this inspection. Name of Firm /ECS Telephone 5W -S-010 Address Date 16 (ENGINEER SEAL) 6. DHEP Approval C. Raid, Jr. 2251•E _ Approved forQllg_,.bedrooms By1 te- Approved Disapproved Conditional Terms of Cond tional Approval CAUTION THE 14UNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH AND ENVIRONMENTAL PROTECTION (DHEP) ISSUES HEALTH AUTHORITY APPROVAL CERTIFICATES BASED SOLELY UPON THE REPRESENT- ATIONS GIVEN IN PARAGRAPH 5 ABOVE BY AN INDEPENDENT PROFESSIONAL ENGINEER REGISTERED IN THE STATE OF ALASKA. THE DHEP DOES THIS AS A COURTESY TO PURCHASERS OF HOMES AND THEIR LENDING INSTITUTIONS IN ORDER TO SATISFY CERTAIN FEDERAL AND STATE REQUIRE- MENTS. EMPLOYEES OF DHEP DO NOT CONDUCT INSPECTIONS OR ANALYZE DATA BEFORE A CERTIFICATE IS ISSUED. THE MUNICIPALITY OF ANCHORAGE IS NOT RESPONSIBLE FOR ERRORS OR OMISSIONS IN THE PROFESSIONAL ENGINEER'S WORK. (DHEP SEAL) RR4/ej/D18 [Page 2 of 2] 7-19-84 MUNICIPALITY OF ANCHORAGE (MOA) HEALTH AUTHORITY APPROVAL (HAA) CHECKLIST - FEBRUARY 1984 A. FJELL DATA Legal Description: Ct! &eZ cLa&l WtJS Well Classification `s"-IUX If A, B, or C, D.E.C. Approved(Y/N) A;4 - Well Log Present) 4dD'(e4 Date Colleted uiu)�. Total Depth � Cased to'-_) -- Depth of Grouting y,V;:.. Static Water Level 342,4,i( - Pump Set At UWk- Casing Height Above Ground _ ,,L( Sanitary Seal on Casing ) P Electrical Wiring in Conduit AIN) Depression Around Wellhead (Y;0r)<) Separation Distances from Well: To Septic/[ -T 4t on Lot APS On Adjoining Lots GT too To Nearest Edge of Absorption Field.cn Lotti O ; On Adjoining Lots GT/UO To Nearest`Public Sewer Line A/41+ To Nearest Public Sewer Cleancut/Manhole pi= To Nearest Sewer Service Line on Lot A/4 - Water Sample Collected By e- 6&ODCn1 Date Z& Sap$l Water Sample Test Results .5fr%I.56K7-Oe Y Co vents * lrvuw� T4s -f. 1'F �['K ^—d - u wO yAa;, i ksht11a4zo I B. SEPTIC/HOLDING TANK DATA j Date Installed Sd p 7 Size U W P26—f— No. of Compartments . L Standpipes 01N) y es Air -tight Caps ) P> Foundation Cleanout My vo Depression over Tank (YA AJO Date Last Pumped d 3, Llfl�Cf Pumping/Maintenance Contract on File (YIN)JJ4- ; for 04 - Holding Tank -High -Water Alarm (Y/N) AP9- Temporary Holding Tank Permit (Y/N)AV - Separation Distances from Septic/Holding Tank: To Water -Supply %bll 106, To Building Foundation �1 To Property Line 4 w( To' Disposal Field '777 To � ,f -,M ,9.n/Servioe Line AIA- To Stream, Pond, Lake, or Major Drainage 3 2P 'rr 9;.. 3l NiC40, a- A C _ A.. -1 a - i1. ., e.we. Nss+...•.meq. � A } r N..... .. .•a a MNr�l�. [Page 1 of 21 Receipt # `Mita Date Paid: Amount: 2-15-84 C. ABSORPTION FIELD DATA ,. Soils Rating in Absorption Strata-,2y5-t'XJ , Type of System Design Y-- Date Installed 4 - - % ( Length of Field oF- Z 2 f Width of Field ($` Depth of Field 4--t44f;L Gravel Bed Thickness A-6 Square Feet of Absorption Area ;K y $Q Standpipes Present) �eS Depression over Field (YADj AJO Date of Last 149 acy Test .qy 406--T3 Results of Last Adequacy Ibst f5iC.Separation Distance from Absorption Field; (o To Water -Supply Well , /qo f To Property Line To Building Foundation f 2,ol To Existing or Abandoned system on Lot AJ ti ; On Adjoining Lots &-110i) To Water Main/Service Line usA- To Cutbank(if present) IVr4 To Stream/Pond/Lake%r Major Drainage Course QF' IQ ci To Driveway, Parking Area, or Vehicle Storage Area ,2%c) 1 1 Comments &. ; l s ` LIFT - STATION Date Insta Dimensions Size in Gallons _ Manhole/Access (Y/1N) "Pump On" Level at U_ ump Off" Level at High Water Alarm Level at Vent MIN) Tested for Pumping Cycles dur%dequacy Test. Meets MDA' Electrical Codes(Y/N) ** Check Permitted Bedreon Rating Against HAA Request I certify that I have checked, verified, or conforred to all MOA HAA Guidelines in effect on the date of this inspection. Signed Date CoWany 4EGS MOA No 2Lf -02 KBl/d5/s (Page 2 of 21 -- 2-15-84 s c AL85Q1-U jKU11111t111A1, WHINE RNIM IIID. Engineerinq E Enuirormental Studies AUGUST 24 1983 KATHY PINNICK SRA BOX 417—B ANCHORAGE AK 99516 SELLER — KATHY PINNICK BUYER — SUBDIVISION — SOUTH HILLS BLOCK — 2 LOT — 1 ADEQUACY TEST FOR SEWER SYSTEM THE TYPE OF ABSORPTION SYSTEM IS A PIT WITH AN AREA OF 480 SQFT. THE SYSTEM IS CAPABLE OF ACCEPTING 145 GALLONS OF WATER PER DAY. THE SURGE CAPACITY OF THE SYSTEM IS 75 GALLONS. BASED UPON THE TEST DATA THE SYSTEM IS NOT ACCEPTABLE FOR A HOME OF 3 BEDROOMS. SEPTIC TANK ADEQUACY THE EXISTING SEPTIC TANK VOLUME OF 1000 IS ADEQUATE FOR THIS 3 BEDROOM HOUSE. 1200 Test 33rd Aoenue, Suite B • Anchorage, Alaska 99503 • (907) 276-1951