HomeMy WebLinkAboutCHUGACH PARK VIEW LT 6Chugach Park View Lot 6 #090-042 -06 Municipality of Anchorage Development Services Department Building Safety Division On-Site Water and Wastewater Program, 4700 Bragaw St. P.O. Box 196650 Anchorage, AK 99519-6650 Page of www.ci.anchorage.ak.us (907) 343-7904 ON-SITE WASTEWATER DISPOSAL SYSTEM AND/OR WELL INSPECTION REPORT Permit Number: SW070143 PID Number: 090-042-06 Name: Ric Vrsalovik Wastewater System: [] New [] Upgrade Address: PO Box 113004/site: NHN, Indian Rd. ABSORPTION FIELD Phone: Number of Bedrooms: 4 [] Deep Trench ~ Shallow Trench [] Bed [] Mound [] Other: Soil Rating: Total Depth from original grade: LEGAL DESCRIPTION 1.0 GPM/Fi~ North 7.5 / South 7.5 Ft. Block: Lot: 6 Subdivision: Depth to pipe bottom from original grade: Gravel depth beneath pipe: -- Chugach Park View N 3,2 / S 3.0 Ft. N 4.03 / S 4.08 Ft. Township: Range: Section: Fill added above original grade: Gravel Length: N 0 /S0.1 Ft. 30+30=60 Gravel width: Number of lines: I Distance between lines: Well: [] New [] Upgrade 5.0 st. 2.51 17 Ft. Classification (Private, A, B, C): Total Depth: Cased to: Total absorption area: Pipe Material: private 226 Ft. 46.4 Ft 600 Et2 ASTM D3034 Driller: Date Drilled: Static Water Level: Installer: Date Installed: M-W Drilling, Inc. 08/24/07 27.5 Ft. Wilco Contractors 8/6/07 Yield: Pump Set at: Casing Height Above Ground: 8 GPM 211 Ft. 2.5 rt. TANK SEPARATION DISTANCES [] Septic [] Holding [] S.T.E.P. [] Other: T~ To Septic Absorption Lift Holding )ublic/Private Manufacturer: Capacity: Tank Field Station Tank Sewer Line Oreer 1500 Gal. Material: Number of Compartments: we, 125 126 NA NA 125+ steel 2 Surface Water100+ 100+ NA NA--~/! LIFT STATION Size: Manufacturer: Lot Line 100+ 100+ NA NA NA Gal Foundation 40+ 65+ NA NA "Pump on" level at: in "Pump off' level at: in. High water alarm at: in, Curtain Drain NA NA NA NA Pump Make & Model Electrical Inspections performed by: Remarks: BENCH MARK Location and Description: Fill added over drainfields in summer 2009. top of well cap Assumed Elevation: 120.30 Ft. Engineer's Stamp Inspections performed by: Cindy W. Ellis, P.E. Dates: lSt.~6/44-z~['0 ~//1.~o/o7 _~ 2® ~/g/C7 Development Services Department Approval /~e~ 55:¢: Conditional Approval Date: Reviewed and approved by: ~~ff./~~ Date: ]/~/~/~t9 ~a~°~,~/-.. ,E-,o,?? .."~.~ C&e I ~ I See attached sheet ~ ~ Based upon an asbuilt suwey ~e~ I I by Shane Holt, LS-6914; ~ ~ for swing ties. ~ I ~ ~ dated Dec. 1, 2008 Chugach Park View Lot 6 Record Drawing of Well & Septic Development ~.~ Parcel ID No.: 090-042-06 Watkins Fai in Inc. Permit No.: ~070143 June 18, 2010 Billings, MI 59104-2574 ~'~-:" Scale 1 inch = 30 ff (907) 360-3389; ~ellisak~gmail.com A B C FCO 7.6 35.9 ...... CO5 23.5 45.5 ...... CO6 50.6 64.1 ...... ST1 51.8 63.9 ...... ST2 57.7 63.5 ...... DCO1 60.0 64.3 ...... DCO2 61.0 64.3 ...... FS 90.8 86.3 125.7 CO1 76.8 89.1 149.8 CO2 89.4 86.3 127.6 CO3 97.2 111.2 167.6 CO4 115.4 119.2 158.7 MT1 78.9 91.2 151.3 t MT2 91.8 89.6 130.6 MT3 98.9 112.8 168.6 MT4 117.4 , 121.6 160.8 See attached drawing of well and septic system. A B C FCO 7.6 35.9 ...... CO5 23.5 45.5 ...... CO6 50.6 64.1 ...... ST1 51.8 63.9 ...... ST2 57.7 63.5 ...... DCO1 60.0 64.3 ...... DCO2 61.0 64.3 ...... FS 90.8 86.3 125.7 OO1 76.8 89.1 149.8 002 89.4 86.3 127.6 003 97.2 111.2 167.6 004 115.4 119.2 158.7 MT1 78.9 91.2 151.3 MT2 91.8 89.6 130.6 MT3 98.9 112.8 168.6 MT4 117.4 , 121.6 160.8 Chugach Park View Lot 6 ~'~,,~...¥>" it '.c.,.~,-,~ Swing Ties for Well & Septic Development ~..-' '...-r- RicYrsalovikj ~/ 4~1-~'~"~'~.~ Parcel ID No.: 090-042-06 Watkins [n§ineerin§, Inc. Cindy W. Ellis, P.E. P.O. Box 22574i~ ~,.C~dYCE. W.~0s~Ellis...~ June 18, 2010 Billings, MT 59104-2574 Scale i inch = 30 ff (907) 360-3389; cwellisak~gmail.com ST1 ST2 DCO 3 FINAL GRADE 12 I~_I FCO = 106.0 I 102.92~ , 6" INSULATION , 1500 GALLON 102.47 STEEL SEPTIC TANK ~ 102.21 CO1 MT1 MT2 CO2 ~_~ Final Grade = 102.71-103.54 ,- Filter Fabric & Insulation 100.38 fS ~ , ~ ~= / = Note: 96.15 I~orth Trench = 30' long 96.34 Note: Test Hole Relative Depth -- 89.00 No Water 0013~ Mt3 MT4 004 ~ Final Grade = 97.21-97.93 ~ ~-~ 94.73 Note: i_ Filter Fabric & Insulation /-- , ~ ~- ,/ _~_/: Original Grade = I 4" O Pipe ~ 94.38 I 97.02 - 97.80 90.30 Sewer Rock 90.53 South Trench = 30' long ~r91.38 Note: Test Hole Relative Depth = 83.30 SEPTIC SECTION No Water N.T.S. AS- BUILT Note: This revision reflects additional fill placed over trenches. Chugach Park View Lot 6 Revised Record Drawing of Well & Septic Development Ric Vrsalovik Parcel ID No.: 090-042-06 Watkins Engineering, Inc. 49 Permit No.: SW070143 ~ ......... '~ ............. -'-": .... CindyW. Ellis, P.E. P.O. Box 22574 ~07," c~ - ~0~ ..'~ June 18, 2010 Billings, NIT 59104 ~i~'"~.~,~/.~.-'~,~ Not to Scale (907) 360-3389; cwellisak@gmail.com ~o,.' .... '~, M-W Drilling, Inc. eP.O. Box 110378 e Anchorage, AK 99§11e · 907-345-4000 · 907-345-3287 Fox, Job No. 07-140 Permit No. SWO701A3 GROUNDWATER WELL AS-BUILT & LOG I W ell Owner: Ric Vrsalovic L gal Description: Chugach Park View Lot 6 NHN indian Rd, Anchorage Use of Well: Domestic CONSTRUCTION Hble Depth: 226 Casing Size: 6" Cased To: 46.38' D~rill Method: Air Rotary Wall: .025 Well Completion: Open end Screen Perforated Screen/Perforation description: Grout Notes: ( 4 ) Sack(s) of No. 8 Bentonite granules I Notes: Bed Rock at 18', used GeoRock to take casing to 46' while grouting ,.[ Disinfected: Yes Method: Chlorine Tablets v~ell Development Method Air Su[ge ~ Nbtes: SJ[atic water level (SWL) 27.5 below top of casing (TOC). Material: A 53 Steel Perf. Method: V~'ell yield test at IV ;ethod: Air lift ~ar~ Date: P~Jmp install Date: Depth in feet from 8 gallons per minute (GPM) for ~ hour(s) with 10o% 08/22/07 Completion Date: _ 08/24/07 WELL LOG ~ of drawdown (DD) from static level(SWL). 0 of casin Details of formations penetrated, size of material, color and miscellaneous details. TO 2.5 Casing Stick Up !.5 TO 5 ,5 TO _1_8 L8 TO 20 ~'0 TO 22( TO TO TO TO TO TO TO TO TO TO TO Organic Overburden Gravel, & Course d J k Bedrock: Black Grey Sittstone Argillite Water 9~ age - ~' ~ N,', 6129 15, 2'}!i!{! ~ 57F:M a,~,,:e~'~.on en~i,nee,"i~ .... Merk Begich Mayor Development Services Department Building Safety bivision On-Site Water & Wastewater Program 4700 Elmore I~o~d P.O. Box 196650 Anchorage, AK 99507 www.mum_~orq/onsite (907) 343-7904 Well Drilling Permit Number: Parcel Identification Number: Il Legal D¢~ription Pump Installation Log Pump Installation Date: C~ ~ Q,-]- , 0 ~) Pump Intake Depth Below Top of Well Casing: feet Pump Manufaetnrer's Name: brand July 1, r Wayne/ Westberg, 2010 Pump Size [ hp Pitless Adapter garial Depth: ~ feet Well Disinfected Upon Compl~ion?,~es ~ No Comments: Attention: The ptwnp instiller shall provide a pump installation log to *.he DSD within 30 days of pump installation. SGS Reft// 1102509001 Client Name Watkins Engineering Printed Date/Time 06/10/2010 11:24 Project Name/// Chugach Park View Lot 6 Collected Date/Time 06/04/2010 10:00 Client Sample ID Chugach Park View Lot 6 Received Date/Time 06/04/2010 12:25 Matrix Drinking Water Technical Director Stephen C. Ede Sample Remarks: Allowable Prep Analysis Parameter Results LOQ Units Method Container ID Limits Date Date Init Metals by ICP/MS Arsenic ND 5.00 ug/L EP200.8 C (<10) 06/07/10 06/07/10 KDC Waters Department Total Nitrate/Nitrite-N ND 0.100 mg/L SM20 4500NO3-F B (<10) 06/04/10 AYC Microbiolog~ Laboratory E. Coli Total Coliform Neaative I 100mL SM20 9223B A 06/04/10 DLC Neffative 1 100mL SM20 9223B A 06/04/10 DI.,C / ! o o ELES, ES M'T, THE INFORMATION HEREON IS FOR THE USE OF LENDING INSTITUTIONS SPECIFICALLY TO SHOW ANY CONFLICTS BETWEEN EXISTING STRUCTURES AND PLATED LOT LINES OR EASEMENTS AND IS NOT TO BE USED FOR POSITIONING ADDmONAL STRUCTURES OR FENCELINES. EASEMENTS OF RECORD, OTHER THAN THOSE SHOWN ON THE RECORDED PLAT, ARE NOT SHOWN HEREON. NOTE: ANY FENCELINES SHOWN ARE LOCATED APPROXIMATELY AND ARE NOT TO BE USED TO DETERMINE PROPERTY LINES OR LOCATE STRUCTURES. F'INAL STR~JSTURE AS-BUILT AS-BUILT SURVEY SCALE:I" = 60' ] HEREBY CERTIFY THAT I HAVE PERFORMED A MORTGAGEE'S INSPECTION OF THE FOLLOWING DESCRIBED PROPERTY. LOT 6, CHUGACH PARK VIEW SUB. ANCHORAGE RECORDING DISTRICT, ALASKA AND THAT THE IMPROVEMENTS SITUATED THEREON ARE WITHIN THE PROPERTY LINES AND NO VISIBLE ENCROACHMENTS EXIST OTHER THAN NOTED. DATED AT ANCHORAGE, ALASKA THIS 1ST DAY OF DECEMBER 200§ . -- HOLT LA-ND SURVEYING 10481, FB 128-]0,135-1 TEL. 345-5513 MUNICIPALITY OF ANCHORAGE Development Services Department On-Site Water & Wastewater Program 4700 South Bragaw Street P.O. Box 196650, Anchorage, AK 99519-6650 (907) 343-7904 ON-SITE WASTEWATER DISPOSAL SYSTEM I WATER SUPPLY PERMIT Initial Date Issued: Jul 06, 2007 Expiration Date: Jul 05, 2008 Permit Number: SW070143 Legal Description: CHUGACH PARK VIEW LOT 6 Design Engineer: 0844 WATKINS ENGINEERING Owner Name: RIC VRSALOVIK Owner Address: PO BOX 113004 ANCHORAGE, AK 99511- Parcel ID: 090-042-06 Site Address: NHN INDIAN ROAD Lot Size: 229881 SQ. FT. Total Bedrooms: 4 Permit Bedrooms: 4 This permit is for the construction of: [] DisposalField [] SepticTank [] Holding Tank [] Privy [] Private Well [] Water Storage Ail construction must be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal Code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations ( 18AAC72 ) and Drinking Water Regulations ( 18AAC80 ). 3. The engineer must notify DSD at least 2 hours prior to each inspection. Provide notification by calling (907) 343-7904 ( 24 hours ). ( Not required for a Water Supply Permit only ). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must be either: A. Open and closed on the same day. B. Covered, sealed, and heated to prevent freezing. Date: Municipality of Anchorage Development Services Department ,, '~ .... " Building Safety Division On-Site Water and Wastewater Program 4700 Bragaw Street ~ P.O. Box 196650 Anchorage, Alaska 99519-6650 www.muni.orglonsite (907) 343-7904 ON-SITE SEWER/WELL PERMIT APPLICATION FOR A SINGLE FAMILY DWELLING Parcel I.D. 090-042-06 Property owner(s) Ric Vrsalovik Mailing address. PO Box 113004 Site address Indian, AK ~lJ ~'*~[",)~ Legal description (Sub'd., Block & Lot) Chu,qach Park View Lot 6 Legal description (Township, Range & Section) Lot Size 229,881 .Sq. Ft. Day phone Zip Code 99511 Zip Code Number of Bedrooms 4 THIS APPLICATION IS FOR ([] all that apply): Absorption Field Septic Tank Holding Tank Privy [] Pdvate Well [] Water Storage [] THIS APPLICATION IS AN:  Initial Upgrade [] Renewal I certify that the above information is correct. I further certify that this application is being made for a Single Family Dwelling and is in accordance with applicable Municipal Codes. (Signature of pmper~ owner or auth(~r[zed agent) Permit/Rush Fees: /~0 ~" Date of Payment: Receipt Number. ~ev. 11~5) Waiver Fees: Date of Payment: Receipt Number. Watkins Engineering, Inc. P.O Box 110443, Anchorage, AK 99511 (907)349-1851 cwellis@gci.net July 3, 2007 Municipality of Anchorage Development Services Department Building Safety Division On-Site Water and Wastewater Program P.O. Box 196650 Anchorage, AK 99519-6650 RE: Chugach Park View Lot 6; Indian, AK Well and Septic System Permit To Whom It May Concern: Attached please find the application and supporting documentation to install a well and septic system for a proposed 4 bedroom house in Indian. The proposed septic design is based upon a test hole dug on April 11, 2007. The hole (Test hole #1) was dug to 14.5 ft with no water encountered. After a 7 day monitoring period, no water was detected. The proposed drainfield is a 5 ft wide trench installed in a sand and gravel layer between 3.5 ft and 7.5 ft. A percolation test conducted between 5.0 ft and 5.5 ft resulted in a rate of less than 1 minute per inch. The soil quality was adequate to act as a natural sand filter, An application rate of 1.0 gpd/ft~ is used in the design. The soil log is attached. Proposed Soil Absorption System: 4 Bedrooms x 150 GPD/BR = System Type: Application rate: 600 GPD / 1.0 gpd/ft~ = Maximum Depth: Effective Depth: Reduction Factor: Proposed Length: Absorption Area: 600 GPD Shallow trench 1.0 gpd/~ 600 fff required 8.5 ft 4.0 ft 0.50 60 ft (2@30 ft) 600 · Well & Septic Permit Application Watklns Englneerfng, Inc.; July 3, 2007; page 2 The alternate drainfield can be located within a 30 ft radius of Test hole #2, which had similar soil quality to Test Hole #1. The alternate drainfield will have the same design parameters as detailed above, but with a maximum depth of 7.5 ft. There are 2 creeks running through the property. The proposed septic system will maintain a separation distance of 100 ft to the creeks. It will be located more than 100 ft from all private wells in the area. I am not aware of any adverse effect that this upgrade would have on any adjacent properties' water and wastewater treatment needs. Thank you for consideration of this permit application, if you have any questions or need further information, please call me at 349-1851. Sincerely, Cindy W. Ellis, P.E. President Lot1 ~ Gamess /__/ ~USS~RVEYNO.3200 NOTE: This is an engineering dining, not a sumey. L~tions are approximate. Chugach Park ~ ~t 6 July 3, 2007 Anchorage, AK 99511-0443 S~le 1' - 200' Phone: (907) 349-1851 Fa~ (907) 349-1934 // ~,~ ~. ~ ~'~_~ / ~ ~ ~, / ~0~/~ / ~o~.' ~ x '~-~a~ ~ ~ ~ >~ ......... ,I ~ o ~ ~ ~ ~~ // · I Chugach Park ~ Eot 6 Proposeg Well ~ ~p~c Development ~c wsa~ovlk Watkl~s E~gl~eed~g, Ond~ W. EII~s, P.E P.O. Box 110443 lul~ 3, 2007 Anchoragm Alaska 99511~443 ~:., ................. ,,:~ S~le 1 ~nch - 30 ~ ~onm Municipality of Anchorage Development Services Department Building Safety Division On-Site Water end Wastewater Program 4700 South nragaw St. P.O, Box 196650 Anc~qorage, AK 99519-6650 www cfi anchoreae ak us (907) 343-79O4 Soils Log Performed For:. Ric Vrsalovik Legal Description: Chugach Park View Lot 6 {Test Hole #1 I 1- 2- 3- 4- 5--- ~ - Percolation Test Date Perfom'md: 4/11/2007 Township. Range. Section: S~ope __~20% i Site Plan SEE ATTACHED I- 11- WAS GROUND WATER ENCOUNTERED? NO IF YES, AT ~M~AT DEPTH? -- Depth to Water After ~,,.o.~to~,~? Dry Date: 4/18/2007 Reading Date Gross Time Net Time Depth to Water Net Drop 1 4/11/07 12:04.12:05 1 6"-0 6" 2 12:08-12:1o 2 6"-0 6" 3 12:24.12-.26 2 6"-0 6" 4 12~9-12:32 3 6"-0 6" 5 12:32-12:36 4 6"-0 6 12:50-12:54 4 6"-0 7 1:02-1:06 4 6'-0 6' 19' PERCOLA'RON RATE <:1 (mmu~e~) PERC HOLE DIAMETER 6# TEST RUN BETWEEN 50 FT AND 5.5 FT COMMENTS Took 5 gallons of water as presoak, in 2 minutes. 'Soil quali~uate as natural sand filter. PERFORMED By: CindyEIlislRockyTrainor , I , ~-~g//("/'~ CERTIFYTHATTHISTESTWAS PERFORMED IN ACCORDANCE W1TH ALL STATE AND MUNICIPAL GUIDEIt~ES IN EFFECT ON THIS DATE, DATE: 4/25/07 Municipality of Anchorage Development Services Department Building Safety Division On-Site Water and Wastewater Program 4700 South Bragaw St. P.O. Box 19~650 Anchorage. AK 99519-6850 (907) 343-79O4 Soils Log - Percolation Test Perforated Foc Ric Vrsalovik Date Performed: 4/11/2007 Legal Description: Chugach Park View Lot 6 Township. Range, Section: 2- 3- 4- 5- 6- ITest Hole #2 I Stope Site Plan SEE ATTACHED I 11- WAS GROUNDWATER ENCOUNTERED? NO $ L IF YES. AT WHAT DEPTH? -- O ~,,~to~? Dr,/ ~ Oaa: 4118/2007 I 20% Reading Date Gross T~me Net Time Depth lo Water Net Drop 1 4111/2007 1:19-1:22 3 6"-0 6" 2 4111/2007 1:23-1:29 6 6"-0 6" 3 4/11/2007 1:30-1:37 7 6"-0 6' 4 4111/2007 1:39-1:47 8 6"-0 6' 5 4/11/2007 1:48-1:56 8 6"-0 6' 6 4111/2007 1:56-2:04 8 6"-0 6" 7 4111/2007 2:05-2:13 8 6"-0 6" 15- 16- 17- 18- 19- 20- PERCOLA'RON RATE 1.3 tr,,~W,~) PERC HOLE DIAMETER TEST RUN B~EN 5 FT AND 5.5 FT COMMENTS Took 5 gallons of water as presoak. Soil~adequate as natural sand filter. PERFORMED BY: Cindy Ellis I Rocky Trainor I ~/~--~ CERTIFY THAT THIS TEST W~ASr PERFORMED IN ACC~AND MUNICIPAL (~UIDELIN0~:-~ IN EFFECT ON THIS DATE. DATE: ~--~ 0 '7 Municipality of Anchorage ~. Development Services Department ' ..... '~ Building Safety Division On-Site Water and Wastewater Program 4700 South Bragaw SL P.O. Box 196650 Anchorage, AK 99519-6650 www.ci.anchorage.ak, us (907) 343-7904 ON-SITE SEWER/VVELL SUBMITTAL COMMENT SHEET To: Watklns Engineering Legal description: Chuflach Park View~ L6 [~3Permlt E~C,O.S.A. [-[Inspection Report The attached paperwork has been reviewed and is being returned for the following reasons: ~¢-1. With a perc rate of less than 1 min/in, the application rate should be 1 GPD. o~-2. A subsurface disposal field may not be Iocated...(c) Where there is bedrock or any other impermeable barrier or where fractured or weathered bedrock occurs within six feet of the bottom of the absorption area. AMC 16.65.060.A.2 o~ 3. Show the worse case test hole elevation. ~ 4. If, after recalculating, the trench length is over 50' long, entered at the midpoint. Name of reviewer: Deb Date: 6127J07 Please supply the necessary information and re-submit your request. LEAVE THIS FORM ATTACHED TO THE PAPERWORK Watkins Engineering, Inc. P.O Box 110443, Anchorage, AK 99511 (907)349-1851 cwellis@gci.net June 19,2007 Municipality of Anchorage Development Services Department Building Safety Division On-Site Water and Wastewater Program P.O. Box 196650 Anchorage, AK 99519-6650 RE: Chugach Park View Lot 6; Indian, AK Well and Septic System Permit To Whom It May Concern: Attached please find the application and supporting documentation to install a well and septic system for a proposed 4 bedroom house in Indian. The proposed septic design is based upon a test hole dug on April 11, 2007. The hole (Test hole #1) was dug to 14.5 fl with no water encountered. After a 7 day monitoring period, no water was detected. The proposed drainfield is a 5 ft wide trench installed in a sand and gravel layer between 3.5 ft and 7.5 ft. A percolation test conducted between 5.0 ft and 5.5 ft resulted in a rate of less than 1 minute per inch. The soil quality was adequate to act as a natural sand filter. An application rate of 1.2 gpd/~ is used in the design. The soil log is attached. Proposed Soil Absorption System: 4 Bedrooms x 150 GPD/BR = System Type: Application rate: 600 GPD / 1.2 gpd/ft~ = Maximum Depth: Effective Depth: Reduction Factor: Proposed Length: Absorption Area: SUPERSEDED 600 GPD Shallow trench 1.2 gpd/~ 500 · required 8.5ft 4.0ff 0.50 5O ft 500 fff The alternate drainfield can be located within a 30 ft radius of Test hole #2, which had similar soil quality to Test Hole #1. The alternate drainfield will have the same design parameters as detailed above. Well & Septic Permit Application Watklns Engineering, Inc.; June 19, 2007; page 2 There are 2 creeks running through the property. The proposed septic system will maintain a separation distance of 100 ft to the creeks. It will be located more than 100 ft from all private wells in the area. I am not aware of any adverse effect that this upgrade would have on any adjacent properties' water and wastewater treatment needs. Thank you for consideration of this permit application. If you have any questions or need further information, please call me at 349-1851. Sincerely, Cindy W. Ellis, P.E. President L~tl.~.~~ ~l~.~well septic / 2 / to north to north! ! / Oamess / f --- ~ US SURVEY NO.3200 / '~~~ f~"~'. / / . / PROPOSED,~ / X-~.b-~-~~[~ ,~e~/ .~.,,~ / /.+v /~ X x-+~~z , WELL SITE o*~UP'~'l~~/~ 6~ NOTE: This is an engineering dining, not a sumey. L~fions are approximate. Chugach Park~ew Lot 6 ~oposed Well & Septic Development Watkins Engineering, Inc ,~.......-.; ..~& ~ Ric V~lovik ~.. June ]8, 2007 Anchorage, AK 995[]~443 '~.. "'.. ..'"?~ ~le ~" - 200' Phon~ (907) 349-[85[ Fa: (907) 349-[934 I ~ ,,< ',,. t_x..._ ~,~--~,. ~. w / ,.y x I c~ ,., / / CO C.O -J %' c~J "'.-' / Z W / / ~ ".. ~ / ~'~}C\- / '*/ / / -'.~_ x. ,'%~.-...,,/ /:::-4"~ -;," .. ,._,.o.. 8[ / /' ~ ~ ..,o=, ~"'" / / \ / O.,M.p ~. I x~,." ~ .,~ >,. ~ ~-~=~o- /~'~ I ChuDach Park~ewLot6~... ~ : Proposed Well & ~p~c D~elopment %?'..~,~..~.....':~.L Parcel ID No: 09~42~6 Cindy W. Ellis, P.E P.O. Box ZZ0443 June Z5, 2007 Anchorage, Alaska gg5ZZ~443 S~le Z inch - 30 fl ~one: (907) 349-Z85L C MUNICIPALITY OF ANCHORAGE Development Services Department Phone: 907-343-7904 On -Site Water & Wastewater Section Fax: 907-343-7997 Certificate of On -Site Systems Approval Parcel I.D. 090-042-06-000 Legal description CHUGACH PARK VIEW LT 6 Site address 788 INDIAN RD Indian AK 99540 Expiration Date: Current property owner(s) BUCHTA KRISTEN & STEVE 12/7/2023 X The On-site system(s) is/are approved for 4 bedrooms Conditional approval for bedrooms, with the following stipulations: Comments or advisories: Original Certificate Date: 9/7/2023 This Certificate of On -Site Systems Approval (COSA) is intended to demonstrate the subject system(s) is/are in substantial compliance with municipal code. The Municipality of Anchorage, Development Services Department (DSD) issues COSAs based upon representations provided by an independent professional engineer. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. ATTACHMENTS: COSA Checklist X Well Flow Advisory Absorption Field Advisory Nitrate Advisory Tank Age Advisory Arsenic Advisory Other COSA Approval_June 2022 MUNICIPALITY OF ANCHORAGE Development Services Department ' `ice Phone: 907-343-7904 On -Site Water & Wastewater Section Fax: 907-343-7997 Certificate of On -Site Systems Approval Application 1. GENERAL INFORMATION Parcel I.D. 090-042-06 Complete legal description CHUGIAK PARK VIEW LOT 6 Location (site address) 788 INDIAN ROAD INDIAN, AK 99540 Current property owner(s) STEVE & KRISTEN BUCHTA Day phone 2. ON-SITE SYSTEMS SIZED FOR 4 BEDROOMS 3. TYPE OF WATER SUPPLY: ® Private Well ❑ Private Well serving 2 dwelling units ❑ Private Well serving 3+ dwelling units ❑ Community Well or Public ❑ Water Storage 4. TYPE OF WASTEWATER DISPOSAL: ® Private Septic ❑ Private Septic serving 2 dwelling units ❑ Holding Tank ❑ Community Septic or Public Sewer 5. SEPTIC TANK: ® Steel ❑ Plastic ❑ Concrete ❑ Fiberglass Age 16 - See advisory if steel older than 20 years 6. ABSORPTION FIELD: ❑ AWWTS ❑ Bed ❑ Deep Trench ® Wide Trench ❑ Seepage Pit Waiver request for: Expedited review requested: ❑ Distance: By applying for this entitlement, this property is subject to inspection by municipal On-site staff to verify the accuracy of the information provided. COSA Fee $ 5 5Q Waiver Fee $ _ Date of Payment S Z Date of Payment COSA # Waiver # COSA Application.doc COSA Checklist.docx COSA Checklist Legal Description: CHUGACH PARK VIEW LOT 6 Parcel ID: 090-042-06 If more than 1 well and/or septic system on lot, provide separate checklist. Structure served by this system ____ A. WELL DATA Well log is filed with Onsite (or attached) Date drilled 8/24/2007 Total depth 226 ft Cased to 46 ft Sanitary seal is functioning correctly Wires are properly protected Casing height (above ground) 30 in. Date of flow test for COSA 8/10/2023 Static water level at beginning of test 13 ft. Well production at time of test 4+ gpm Water storage tank volume NA gallons Well disinfected for coliform test? Yes No Coliform bacteria is Negative Nitrate ND mg/L Nitrate less than MRL (ND) Arsenic ug/L Arsenic less than MRL (ND) Collected by Date 8/10/2023 Comments __________________________________________________________________________________ B. TANK DATA Measured operating fluid level in septic tank 49” Date of pumping 8/10/2023 Required maintenance completed, if AWWTS Comments: C. LIFT STATION Required maintenance completed Age of lift station years Lift station material Comments: D. ABSORPTION FIELD DATA Which system tested (date installed) 8/6/2007 ALL standpipes present per record drawing Total measured depth from grade 6.2 ft (max) Measured depth to pipe invert from grade 2.3 ft (min) N/A – pressurized field. Per record drawings, field is insulated. Monitor tubes (MT) go to bottom of effective. (ED) If not, state depth into effective 3.5’ Presoaked required if (Required if house vacant or field not used for more than 30 days prior to date of test) Gallons introduced gallons date Any rejuvenation treatment (past 12 months) N If yes, enter date Adequacy test date 8/10/2023 Results Pass Fluid depth prior to test 1 in Water added 600 gal New fluid depth 3 in Elapsed time 30 min Final fluid depth 1 in Absorption rate 600 gpd FIELD STATUS – POST RECOVERY Effective depth (per record drawings) 49 in (MOA 4.08’ ED) Effective depth used 8 in (Missing ED + Final Fluid Depth) Effective depth (ED) remaining 42 in Comments/Deficiencies: Approximate total measured depths from existing grade. ED per elevation measured shots & appears approximately 7 inches of ED is missing in each trench. No known frost issues & attached owner’s statement. COSA Checklist.docx E. SEPARATION DISTANCES From Private Well on Lot to: (Please enter distances if less than required or if community well on lot) Septic Tank/Lift Station on Lot > 100’ Yes if No ft Neighboring Tank > 100’ Yes if No ft Absorption Field on Lot > 100’ Yes if No ft Neighboring Absorption Fields > 100’ Yes if No ft Community Sewer Main > 75’ Yes if No ft Community Sewer Manhole/Cleanout > 100’ Yes if No ft Private Sewer/Septic Line > 25’ Yes if No ft Holding Tank > 100’ Yes if No ft Animal Containment > 50’ Yes if No ft Manure/Animal Excreta Storage > 100’ Yes if No ft N/A – Served by Community Well (not on lot) or Public Water From Septic/Holding Tank and Absorption Field(s) on Lot to: (Please enter distances if less than required) Building Foundations > 10’ Yes if No ft Tank to Property Line > 5’ Yes if No ft Field to Property Line > 10’ Yes if No ft Water Main > 10’ Yes if No ft Water Service Line > 10’ Yes if No ft Surface Water > 100’ Yes if No ft Wells on Adjacent Lots: Private Wells > 100’ Yes if No ft Community Wells > 200’ Yes if No ft If tank or field is under driveway comment below F. ENGINEER’S COMMENTS G. CERTIFICATION & STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based on procedures outlined in the Certificate of On-Site Systems Approval Guidelines, indicates that the on-site water supply and/or wastewater disposal system appears to comply with applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation, unless noted otherwise. Name of Firm FIRST WATER CONSULTING Phone 907-350-9566 Engineer’s Printed Name CURTIS HUFFMAN, PE Date 9/6/2023 Comments: This investigation was completed in compliance with MOA guidelines, regulations, and best industry practices / methods. The assessment of the condition of the well and septic applies only to the conditions as of the day tested. The flow and absorption rates may change due to subsurface conditions that may not be observed from the surface, changes in land use, local soil characteristics, groundwater levels that may fluctuate during the year, quality of construction (workmanship & materials), the water usage of the family being served by the system and maintenance. The operational life of all well and septic systems are subject to these various and dynamic characteristics and are outside the control of the evaluator of the well and septic system. Therefore, any or NO estimate of how long a system will function satisfactory for current or future occupants or guarantee that no unseen encroachments, deficiencies or discrepancies exist can be given by First Water Consulting & 9/6/23 13030 Sues Way, Anchorage, AK 99516 907-350-9566 / firstwaterAK@gmail.com September 6, 2023 Municipalities of Anchorage On-Site Water & Wastewater Program 4700 Elmore Road Anchorage, AK 99507 LEGAL: CHUGACH PARK VIEW LOT 6 Per your request, an additional site inspection was conducted today to verify field cover. Based on cleanout pipe measurements from existing grade at the end of the absorption fields there was 2.3’, 2.5’, 2.9’ and 2.9’ of cover of these short, insulated fields. These measurements were from the end portions of the fields and appears the cover is greater over the length of the fields. These fields are located below the house in a field that is heavily vegetated with grass, cow parsnip, … and this dead vegetation will provide additional insulation of this undisturbed area. Per the MOA inspection report this field has approximately 4’ effective depth and is supplied from the septic tank to the end of each field. There are also good cleanout pipes for proper maintenance. For your information, there appears to be an existing groundwater monitoring test hole pipe extending 13.8’ below existing grade and was dry. Based on the MOA file of construction, documents, visual observations, and owner statement of not having any known freezing issues, we make the reasonable assumption and determination that there is adequate cover to prevent freezing. Sincerely, Curtis Huffman, P.E. � v a Oo m 00 a L CD W 0) 0 /0 V x 0 to OJ C 0 c U 7 m c cu N �L