HomeMy WebLinkAboutASPEN HIGHLANDS #2 BLK 2 LT 9Aspen Highlands #2 Block 2 Lot 9 #017-013-36 Municipality of Anchorage _ Development Services Department ° Building Safety Division On-Site Water and Wastewater Program, 4700 Bragaw St. P.O. Box 196650 Anchorage, AK 99519-6650 Page of v iA cl.andwage.ak.us (907) 3437904 ON-SITE WASTEWATER DISPOSAL SYSTEM AND/OR WELL INSPECTION REPORT Permit Number. SW070097 PID Number. 017-01336 lh� Eric Trevithick Wastewater System: [Z]New ❑ Upgrade Ma..a 6200 Lake Otis Parkway Anchorage, AK 99507 ABSORPTION FIELD °nais ~m0e of a.amaa 4 O Dm Tr.wr Id S am. Tmdi O ase O kfi a O obar ` Taroaoe LEGAL DESCRIPTION 1.0 0p ? 1i 6 �. sock La SWorwn Dapeibppbmanfrvno`"Wsos Gresmpm b.a.n P" 2 9 Aspen Highlands #2 7.84 it. ft To.nyiy RAW solar Fa ease some aprur V•ea Gray L& Vn 1-2 Fr. 63 Fr. Well: ifZ] New ❑ Upgrade Cr enn rr.ro.a ram 1 osommewbsen rw I 5 Fr. FL cWNvioon (Pone, A B. Q Taal Dever onsa b Tar anapran ars, Pp Manor Private 365 Ft. 171 FL 630 F2 ASTM D3034 PVC paler Oeu Qaee stsbc Were, Level 1n.aaer Oen Yaarea Hefty Drilling Company 7113107 205 FL Red ON Excavating 10125-2612007 yok! Flap Sera Leeeq Yr,yl Above Gmvia TANK 1 GPr 351.5 FL 2 FL SEPARATION DISTANCES 0 septic ❑ Holding ❑ S.T.E.P. ❑ Other. To Septic Absorption Uft Holding lutticTriviste •tli••r o Fpm Tank Field Station Tank Serer urs Anchorage Tank 11,250 aaerw Anna. a carwpr... wa >100' >100' WA WA >26 Steel Two Se w" >100' >100• WA NIA LIFT STATION La Line >5' >1(7 WA WA Gel Ympan'IM to 'Pop ae'Y�•IM f•pb rM. aWmal FaxWesm >V >10' NIA WA ti h Yt Puny Mak• 6 Mona Er.bvl kopomme penanaq by craao-.n None Noted R'""Ae BENCH MARK Lor�aar w Dnapun Garage Slab aresm 100.90 FL 1025=07 OF; Inspections performed by: A. Harala Dates: 1" ;`�4�t .ss•.esir �f t 2nd 1012612007 612007 �.`Q;•• ..•'•••�* Development Services Department Approval * 49TH it �... ... ...f Conditional Approval Date: rf'✓��� � �4 t"1' ;M10U,EL F AtJDERSON; R '•',. ff �pFp••.....•.•• Q� Reviewed and approved by: /NA4P Date: o OF i a Permit No.: SWO70097 Municipality of Anchorage DEVEOPMENT SERVICES DEPARTMENT 4700 Elmore Road Anchorage, AK. 99519-6655 - 343-7904 On -Site Wastewater Disposal System or Well Inspection Report ASPEN HIGHLANDS SUBD., UNIT NO. 2 LOT 9, BLOCK 2 J7.ee3 Sr. LOT 10 LOT 9 .k Fa 8.4m Name �TQ - RNE / ti � WL A B S1 24.7 29.8 S2 1 C4 .4 51.9 C5 75.2 83.5 PLAN AS -BUILT SCALE V - 50' Page 2 of 3 PID No. 017-013-36 LOT 7 4k�,� A temate Site '1n1 L M1 b 2 e LOT B 7113 W Mi00R! BE IN Municipality of Anchorage DEVEOPMENT SERVICES DEPARTMENT 4700 Elmore Road Anchorage, AK. 99519-6655 - 343-7904 Onsite Wastewater Disposal System or Well Inspection Report Permit Number. SWO70097 Page 3 of 3 PID No. 017-013-36 U � 104.6 FHNaA GreOe Ground Geole,d" Fe 95.3 �— 91.5 Drainfield Rock 63' (Trench Length) NOTE: Effective Depth of Trench was Verified at 4.0' During Construction. Monitor Tube Has Been Filled with .2' of Rock. The Pipe Extends to the Bottom of the Trench. PROFILE AS -BUILT - No Scale 103.1 — 85.1 No G,aewlabr ra2aw yr U 95.3 Feb 06 08 04:14p Eric Trevithick Pumpinstallation Log WCAD _�y N .-- _ rl 1 BOW U=kD c.snc _ J � I r e t= J N; €' 907-336-3720 p.2 Alfm ritlm Adapter Manufacturer's Name: C,. YI.A be I I IbOA A Mess Adapter Installer: REGI d zn I _ PUMP TWC StA i"Jr�GrSi%I� t MAW &yVt %CL !' UMCL JU S GiG tri -330 cob& R Pero ll rar CROP TtiPC Tr,. Pvc— CWWSOM tI C vv POWER c at: Tw. u l r g COMB Y? c v✓ l l CIICTMCAU vasa 3 WAIERrowc Tr W�fj��rQ rASM WO r. fr tJ, TO ;7 MTAME srm,en,ae: yo. F Ira L t Orf e 5 T. 32r5 CPEN„�.L F� ' J 7 t ' To_ 65 COMMUNM well was disinfected upon completion_ method: calcium hypochlorite. 00 —n T 0.C+ = Top 04 Cas. YJ MUNICIPALITY OF ANCHORAGE Development Services Department On -Site Water & Wastewater Program 4700 South Bregaw Street P.O. Box 196650, Anchorage, AK 99519-6650 (907) 343-7904 ON-SITE WASTEWATER DISPOSAL SYSTEM / WATER SUPPLY PERMIT Initial Permit Number: SW070097 Legal Description: ASPEN HIGHLANDS #2 BLOCK 2 LOT 9 Design Engineer: 0014 ANDERSON ENGINEERING Owner Name: ERIC TREVITHICK Owner Address: 6200 LAKE OTIS PKWY ANCHORAGE. AK 99507 - Date Issued: Jun 08, 2007 Expiration Date: Jun 07, 2008 Parcel ID: 017-013-36 Site Address: NHN TRACEY WAY Lot Size: 37683 SO. FT. Total Bedrooms: 5 Permit Bedrooms: 5 This permit is for the construction of: ❑✓ Disposal Field ❑,/ Septic Tank ❑ Holding Tank ❑ Privy Private Well ❑ Water Storage All construction must be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal Code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations ( 18AAC72 ) and Drinking Water Regulations ( 18AAC80 ). 3, The engineer must notify DSD at least 2 hours prior to each inspection. Provide notification by calling (907) 343-7904 ( 24 hours ). ( Not required for a Water Supply Permit only). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must be either: A. Open and dosed on the same day. B. Covered, sealed, and heated to prevent freezing. 5. The following special provisions. THE ENTIRE SUBSURFACE DISPOSAL FIELD IS NOT WITHIN A 30 FOOT RADIUS OF A PERCOLATION TEST. THE ENGINEER NEEDS TO DO AN ADDITIONAL PERCOLATION TEST PRIOR TO THE CONSTRUCTION OF THE SEPTIC FIELD. PLEASE SUBMIT STAMPED AND SIGNED RESULTS WITH THE AS -BUILT INSPECTION REPORT. IF THE RESULTS REQUIRE A DESIGN CHANGE, CONSTRUCTION OF THE SYSTEM WILL STOP PENDING ON-SITE REVIEW AND APPROVAL. 7110 Received By: &jell rrvvcd. Ileal srn 514b,'%/,l Municipality of Anchorage Development Services Department Building Safety Division Onsite Water and Wastewater Program 4700 Bragaw Street P.O. Box 196650 Anchorage, Alaska 99519-6650 www.muni.org/onsite (907) 343-7904 ON-SITE SEWER/WELL PERMIT APPLICATION FOR A SINGLE FAMILY DWELLING Parcel I.D. 017-013-36 Property owner(s) EricTrevithick Day phone 345-1400 Mailing address 6200 Lake Otis Parkway, Suite 202 Anchorage, AK Zip Code 99507 Site address Code 99516 Legal description (Sub'd., Block & Lot) Lot 9, Block 2. Aspen Highlands Subdivision No. 2 Legal description (Township, Range & Section) Lot Size 37,683 Sq. Ft. THIS APPLICATION IS FOR (® all that apply) Absorption Field El Septic Tank El Holding Tank ❑ Privy ❑ Private Well n Water Storage ❑ Number of Bedrooms Five (5) THIS APPLICATION IS AN: Initial El Upgrade Cl Renewal ❑ certify that the above information is correct 1 further certify that this application is being made for a Single Family Dwelling and is in accordance with applicable Municipal Codes. (Signature of property owner or authorized agent) Pernit(Rush Fees: Date of Payment: Receipt Number. (Rev. 11/05) /19_' Waiver Fees: _ 3ID� Date of Payment: Receipt Number. ANDERSON ENGINEERING P.O. BOX 240773 ANCHORAGE, AK 99524 522-7773 677-7766 FAX May 23, 2007 Municipality of Anchorage Development Services Department On -Site Water and Wastewater Program 4700 South Bragaw Street Anchorage, AK 99519-6650 Subject: Lot 9, Block 2, Aspen Highlands Subdivision No 2 Septic System Design and Permit Application Impacts to Adjacent Properties Dear Onsite Services Engineer: The owner of Lot 9, Block 2, Aspen Highlands Subdivision No. 2 intends to construct a new five -bedroom home on the lot. We are therefore requesting a permit be issued for the construction of a new well and septic system to accommodate the home. The attached Site Plan and backup documentation identify the location and configuration of the proposed well and septic system along with the alternate site. Existing wells and septic systems in the area are also shown on the attached plans. Drainage arrows are shown on the site plan showing the grade and direction of flow on the lot. The drainage pattern will not be changed as a result of this project. The test holes placed on the lot in the area of the absorption trench and alternate site indicated gravel and sand and silt (SP/GP/GM) material. The percolation rate of the soil was determined to be 1 to less than 1 minute per inch. Soil materials in the percolation zone contained more than 50% sand so not filter is required. No groundwater was found during the placement of the test holes and none was noted during the monitoring period. An application rate of 1.0 gallons per day per square foot was used in the design of the absorption system. We are proposing to place a new 1,500 -gallon septic tank and a 75' long by 5' wide by 4' effective depth absorption trench to treat and dispose of the effluent generated in the house. The elevation of the distribution line in the absorption trench will be 6.0' below the surface and the total depth will be 10.0'. A minimum of 3' of fill or 2' of insulation and 2' of fill will be placed over the absorption trench and 4' over the septic tank. The ground surface on the lot in the area of the absorption trench slopes to the southeast at 5%. No major grade breaks or excessive slopes were noted within 100' of the proposed septic system. The new trench will be constructed parallel with the slope Lot 9, Block 2, Aspen Highlands No. 2 May 23, 2007 Page Two as much as possible in conformance with Municipal requirements. The new septic system will be constructed a minimum of 100' from all wells and any surface water and 10' from the proposed and existing water services in the area. If the system is constructed in accordance with our design the following statements apply: The system, if constructed as designed, will have no adverse impact on the wells in the area or those to be constructed in the future. 2. The system, if constructed as designed, will have no adverse impact on existing septic systems in the area or those to be constructed in the future. 3. The system, if constructed as designed, will have no adverse impact on reserve space, either surface or subsurface, on any lots located in the area. 4. The system, if constructed as designed, will have no adverse impact on drainage patterns in the area. The current drainage pattern will be maintained. Sincerely, Q /� Michael E. Anderson, P.E. Attachments V C.AC E. AVERSON t No. CE -4381 5A 2 11 5 5 �N 6A P 10A 4 �-� O 8 9 5 ADO DIVE 7 10 8 6 b h �� (E .......,.. �1 fir 49th ;:::...............- AREA MAP � �;NICHAEL E. ANDERSON i I cEra�ety:`�� SCALE 1' = 100' LOT 9, BLOCK 2, ASPEN HIGHLANDS SUBDIVISION NO.2 DESIGN FACTORS: SYSTEM REQUIREMENTS: Five Bedroom House 5' WideTrench System Perc. Rate: 1 Min./Inch (Est) 1,500 Gallon Septic Tank Application Rate: 1.0 GPD/SF 4' Drainfield Rock 5 Bedrooms X 150 GPD/1.0 GPD/SF (Application Rate) = 750 SF Absorption Area 750 SF/5 SF/LF'.5 (Red. Factor)= 75 LF Trench Length THEREFORE: Construct an Abosrption Trench 75' Long x 5' Wide x 4' Effective Depth. Flow Line Elevation in Trench to be 6' Below Original Ground Surface. Total Depth to be 10' Below Existing Ground. Provide 4' Cover Over Septic Tank and 3' Cover Over Absorption Trench. Enter Trench at Midpoint with Effluent Flow. 5'6" I Natural Backfill Geotextile Fabric 6" 4'0" 5' Perforated 'C (Holes Down) Drainfield Rock TYPICAL 5' WIDE TRENCH SECTIO"' (NO SCALE) NOTE: Grade Area Over Trench to Drain Away. Minimum 6' Separation From Bedrock. Minimum 4' Separation From Groundwater. Minimum 100' Separation From Wells in the Area. Minimum 100' Separation From Edge of Lake. Performed For. Legal Description: �1� 1 Depth D P] V ;8:� 4 `i7 COMMENTS Municipality of Anchorage Development Services Department Building Safety Division On -She Water and Wastewater Program 4700 South Bragaw St. P.O. Box 196650 Anchorage, AK 99519-6650 www.el anchorage.ek.us (907) 3437904 Soils Log - Percolation Test 'M,CV rn+►ev` Township, WAS GROUND WATER _ ENCOUNTERED? Net Time .Pa Net Drop IF YES, AT WHAT DEPTH? 14 C Depth to Water After F Monitoring? E ' Date: fdd Z. �49Tl� N s Date Performs e. Section: ++' : *X'CHAEI E. ANUR50N f, )I CF • 438 4 off#* '3 21 She Plan Reading Date Gross Time Net Time Depth to Water Net Drop 3 2'i- c1 14 � l• 8 9.i.g � � .QE/ rcn�.�tnu�n Mic I Imnaauntat FERC HOLE DIAMETER TEST RUN BETWEEN FT 'AND i(c ii FT PERFORMED BY: - I ; 1L4 Art—f` /CJjAWX0AATIFYTHATTHISTESTWAS PERFORMED IN ACCORDANCE WITH ALLSTATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE. DATE: E- 2.3 — 07 Municipality of Anchorage Development Services Department Building Safety DMsion y2 On -Site Water and Wastewater Program 4700 South Bragaw St. P.O. Box 196650 Anchorage, AK 99519.6650 w"ww.cl. enchoraoe.ek.us (907) 343-7904 Performed For. Legal Description: J[f-V OF• 44%1 00,590NE R'S 99.01}9' �•"f`� 49tH •v pep c AUU1A Ft E. ANC]A.;GNdw ��,he • . a, P TA Soils Log - Percolation Test; LL�e zFLt C - Til. rr1ft e(L Date Performed: 3 O 1 ownship, Rarige, Section: Cope Site Plan 11 1 16-I WAS GROUND WATER ENCOUNTERED? a IF YES, AT WHAT DEPTH?NO - _ L Depth to Water After •1!-`rC" D Monhorinpl E ' Data: (� Ci I Reading I • Date I Gross Tame I Net Time I Depth to Water Net Drop I PERCOLATION RATE A . L.6a+t•ahia0 PERC HOLE DIAMETER TEST RUN BETWEEN FT 'AND SSL"✓ FT PERFORMED BY: %A )"T I lqrjlAkq, 6 JERSOCERTIFY THAT THIS TEST WAS PERFORMED IN ACCORDANCE WITH ALLSTATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE. DATE: S -7 -?-07 Municipality of Anchorage ae'`p(cNGIN CIr&,O Development Services Department r * 49�y v .74 Building Safety Division -„•-- On-SReWater and Wastewater Program yyj%f�:�•• � 4700 South Bragaw St. !......••.............. . P.O. Box 195650 Anchorage, AK 99519.6650 ;AUCAAEL L ANDERSON e www N anchorao eo us v C. t, CE -4381 •`• e (907)343.7904 I����•��.�q f Fo S r Soils Log - Percolation Test �/ pq�rEssw���%, Performed For. r� , � ������ �ilcl�i Gl/ 1'1'}FI.� 1 Date Performed: to Legal Description:a / Township, Range, Section:, . J7 Y_1 Y Z Slope Sde Plan iFeet) d� /r .•�• F• 6- 7. r 10- 11. 12- 13- ' 14- ,B L; f -",/ COMMENTS WAS GROUND WATER ENCOUNTERED) S IF YES, AT WHAT DEPTH?_ L DaPth to Water Amer D Monitoring? WoEt%K E E Date 4Dale PERCOLATION RATE TEST RUN BETWEEN Net Tans Depth to Water Net Drop 3.1� i • SL 6 /2 3.70 �.7 (S. 3 ta.nn.✓n�l PERC HOLE DIAMETER FT 'ANO 5;.o FT PERFORMED BY: 1114 1� 0 CERTIFY PERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THS DATE. DATE: IS TEST WAS Municipality of Anchorage Development Services Department Building Safety Division / On -Site Water and Wastewater Program 4700 South Bragaw St. P.O. Box 196650 Anchorage, AK 99519-6650 www.ci.anchorage.ak.us (907)343-7904 ON-SITE SEWER/WELL SUBMITTAL COMMENT SHEET To: Anderson Enstineerina Legal description: Aspen Highlands #2. B2 L9 ®Permit ❑C.O.S.A. ❑Inspection Report The attached paperwork has been reviewed and is being returned for the following reasons: 1. The proposed trench location is not parallel to the contours of the slope. Please provide a cross- section of the trench that shows that the bottom will not encroach on the required separation distances. Name of reviewer. Deb Date: 6/7/07 Please supply the necessary information and re -submit your request. LEAVE THIS FORM ATTACHED TO THE PAPERWORK \ Municipality of Anchorage .. Development Services Department *A. Building Safety Division OnsiteWater and Wastewater Program 4700 South Bragaw St. P.O. Box 196650 Anchorage, AK 99519-6650 www.ci.anchorage.ak.us (907)343-7904 ON-SITE SEWER/WELL SUBMITTAL COMMENT SHEET To: Anderson Engineering Legal description: Aspen Highlands #2.82 L9 ®Permit ❑C.O.S.A. ❑Inspection Report The attached paperwork has been reviewed and Is being returned for the following reasons: 1. The site plan shall have a description of the topography, areas of excessive slope, and extent of slopes and surface drainage patterns within 100 feet of any part of the system or portion of the lot Intended for use for on-site wastewater disposal. AMC 15.65.030 D. Please provide this information on the site plan. v 2. A subsurface disposal field may not be installed in an accepting soil stratum having a percolation rate faster than one minute per Inch without installing a filtration layer. If the Insitu soil meets the MOA requirements for a filter material, an additional filtration layer is not necessary. J 3. Please use the application rate for a filter material. Name of reviewer: Deb Date: 5/24107 .S13U 7-alkej w/ /vlke. SJC. slopes 901�'q ,n Ae o�rOstr dirccfion Please supply the necessary information and re -submit your request. LEAVE THIS FORM ATTACHED TO THE PAPERWORK ANDERSON ENGINEERING P.O. BOX 240773 ANCHORAGE, AK 99524 522-7773 677-7766 FAX May 23, 2007 Municipality of Anchorage Development Services Department On -Site Water and Wastewater Program 4700 South Bragaw Street Anchorage, AK 99519-6650 Subject: Lot 9, Block 2, Aspen Highlands Subdivision No 2 Septic System Design and Permit Application Impacts to Adjacent Properties SUP '• b E Dear Onsite Services Engineer: The owner of Lot 9, Block 2, Aspen Highlands Subdivision No. 2 intends to construct a new five -bedroom home on the lot. We are therefore requesting a permit be issued for the construction of a new well and septic system to accommodate the home. The attached Site Plan and backup documentation identify the location and configuration of the proposed well and septic system along with the alternate site. Existing wells and septic systems in the area are also shown on the attached plans. Drainage arrows are shown on the site plan showing the grade and direction of flow on the lot. The drainage pattern will not be changed as a result of this project. The test holes placed on the lot in the area of the absorption trench and alternate site indicated gravel and sand and silt (SP/GP/GM) material. The percolation rate of the soil was determined to be 1 to less than 1 minute per inch. No groundwater was found during the placement of the test holes and none was noted during the monitoring period. An application rate of 1.2 gallons per day per square foot was used in the design of the absorption system. We are proposing to place a new 1,500 -gallon septic tank and a 63' long by 5' wide by 4' effective depth absorption trench to treat and dispose of the effluent generated in the house. The elevation of the distribution line in the absorption trench will be 6.0' below the surface and the total depth will be 10.0'. A minimum of 3' of fill or 2" of insulation and 2' of fill will be placed over the absorption trench and 4' over the septic tank. The ground surface on the lot in the area of the absorption trench slopes to the southeast at 5%. The new trench will be constructed parallel with the slope as much as possible in conformance with Municipal requirements. The new septic system will be constructed a minimum of 100' from all wells and any surface water and 10' from the Lot 9, Block 2, Aspen Highlands No. 2 May 23, 2007 Page Two proposed and existing water services in the area. If the system is constructed in accordance with our design the following statements apply: The system, if constructed as designed, will have no adverse impact on the wells in the area or those to be constructed in the future. 2. The system, if constructed as designed, will have no adverse impact on existing septic systems in the area or those to be constructed in the future. 3. The system, if constructed as designed, will have no adverse impact on reserve space, either surface or subsurface, on any lots located in the area. 4. The system, if constructed as designed, will have no adverse impact on drainage patterns in the area. The current drainage pattern will be maintained. Sincerely, 74.aj Michael E. Anderson, P.E. Attachments SU 'DED D N m m ,may z }dt� 06 =(D N6. u00. W D C) N co N 0 r E Z �°l O �o � N H N M. _ D r rn _ o u < F c D m woti z R b.0 �gs{ / •1 / e / �00•00't 148.98 rte• •, e ' .SIOA „ • Z � 9�•�� 6 •� W , 0 .••• `\q fie 00,50N / v SUP RS DF F¢ Q CL� II W Wa � U N O m g Z)Y (n U (n OJ � 0 mn Z 00 _ - I z w / a U) / Q LOT 9, BLOCK 2, ASPEN HIGHLANDS SUBDIVISION NO.2 DESIGN FACTORS: SYSTEM REQUIREMENTS: Five Bedroom House 5' WideTrench System Perc. Rate: 1 Min./Inch (Est) 1,500 Gallon Septic Tank Application Rate: 1.2 GPD/SF 4' Drainfield Rock 5 Bedrooms X 150 GPD/1.2 GPD/SF (Application Rate) = 625 SF Absorption Area 625 SF/5 SF/LF'.5 (Red. Factor)= 62.5 LF Trench Length THEREFORE: Construct an Abosrption Trench 63' Long x 5' Wide x 4' Effective Depth. Flow Line Elevation in Trench to be 6' Below Original Ground Surface. Total Depth to be 10' Below Existing Ground. Provide 4' Cover Over Septic Tank and 3' Cover Over Absorption Trench. Enter Trench at Midpoint with Effluent Flow. S UPEd®Ed 5'6" Natural Backfill Geotextile Fabric Ia 4'0" 5' Perforated FC (Holes Down) Drainfield Rock ICAL 5' WIDE TRENCH SECTION (NO SCALE) NOTE: Grade Area Over Trench to Drain Away. Minimum 6' Separation From Bedrock. Minimum 4' Separation From Groundwater. Minimum 100' Separation From Wells in the Area. Minimum 100' Separation From Edge of Lake. No. cEa i 0 ANDERSON ENGINEERING P.O. BOX 240773 ANCHORAGE, AK 99524 522-7773 677-7766( MEMORANDUM DATE: July 9, 2007 TO: Deb Wockenfuss FROM: Mike Anderson, P.E. SUBJECT: Lot 9, Block 2, Aspen Highlands No. 2 Permit No. SW070097 Revised Well Location The well location for the subject lot has been moved to allow room for construction of the septic system on the lot to the west. The new location will have no adverse impacts on wells or septic systems in the area. Please review this data and revise the permit accordingly. • 4_ Municipality of Anchorage On-Site Water and Wastewater Program < (907) 343-7904 SA ETY CERTIFICATE OF ON-SITE SYSTEMS APPROVAL Parcel LD. 017-013-36 Expiration Date: / i! - IC( 1. GENERAL INFORMATION Complete legal description ASPEN HIGHLANDS#2 BLOCK 2,LOT 9 Location (site address) 13001 TRACY WAY,ANCHORAGE,AK 99516 Current Property owner(s) KYLE & MARNE J SHAFER Day phone Mailing address 13001 TRACY WAY,ANCHORAGE,AK 99516 Real Estate Agent Day phone 2. TYPE OF DWELLING: ® Single Family (w/wo ADU) ❑ Duplex ❑ Multiple Dwellings (Single Family and/or Duplex) 3. NUMBER OF BEDROOMS: 4 4. TYPE OF WATER SUPPLY: TYPE OF WASTEWATER DISPOSAL: Individual Well ® Individual El Individual Water Storage ❑ Holding Tank ❑ Community Class Well ❑ Community ❑ Public Water System ❑ Public Sewer ❑ Waiver/Variance request for: Distance: Received by: Date: /e//7V/0 COSA to be released to eer,unless otherwise requested by the engineer. COSA Fee $ SZ(g. Waiver Fee $ Date of Payment 16 ! 10 r r(g Date of Payment Receipt Number 4* 1626 Receipt Number COSA# OSC11 l540 Waiver# 5. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based on procedures outlined in the Certificate of On-Site Systems Approval Guidelines for this application, shows that the on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is (are) in compliance with all applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation. Name of Firm ANDERSON CONSTRUCTION & ENGINEERING Phone 345-3377 Address 4640 SHOSHONI DRIVE,ANCHORAGE,AK 99516 Engineer's Printed Name MICHAEL N.ANDERSON,PE Date 10/02/2018 F A ° a o 6. DSD SIGNATURE °°°" ' ° ;' ° a System #1 Approved for ! bedrooms. ;P MICHAEL TI.VARE,RSON F*', CE..o469 System #2 Approved for bedrooms. / 4 11)Disapproved. ��` •? Conditional approval for bedrooms, with the following stipulations: \ ON-SITE WATERAND;12S WASTEWATER m PROGRAM 9 �4 � By: t,w ate 4 Original Certificate Date: (° The Municipality of Anchorage Development Services Division (DSD) issues Certificates of On-Site Systems Approval (COSA) based only upon the representations given in paragraph 5 by an independent professional civil engineer registered in the State of Alaska. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. 7. ATTACHMENTS: COSA Checklist X Nitrate Advisory • Septic System Advisory Arsenic Advisory Well Flow Advisory Other • COSA blue sheet 10-10-12.doc If more than 1 septic system is on the lot: COSA Checklist# of Structure served by this system _ Certificate of On-Site Systems Approval Checklist Legal Description: ASPEN HIGHLANDS#2 BLOCK 2,LOT 9 Parcel ID: 017-013-36 A. WELL DATA Well type Private If A, B, or C provide PWSID # Well Log (Y/N) Y Date completed 7/13/2007 Sanitary seal (Y/N)Y Wires properly protected (Y/N)Y Total depth 365 ft. Cased to 171 ft. Casing height (above ground) 18+ in. FROM WELL LOG AT INSPECTION Date of test 7/1312007 612912018_ Static water level 205 ft. 242 ft. Well production 1 g.p.m. 1.2 g.p.m. WATER SAMPLE RESULTS: Coliform NEG colonies/100 mL Nitrate_4. ' 3 mg/L Arsenic: ND ug/L Date of sample: 9/28/2018 Collected by: FIRST WATER C.S. B. SEPTIC/HOLDING TANK DATA Tank Type/Material SEPTIC/STEEL Date installed 10/26/2007 Tank size 1250 gal. Number of Compartments 2 Cleanouts (Y/N) Y Foundation cleanout (Y/N) Y Depression over tank (Y/N) N _ Hi h water alarm (Y/N) N Date of pumping IC-41—Ig ✓'l1`i'g Pumper Crte 'tar (7144-1° C. ABSORPTION FIELD DATA Date installed 10/25/2007 Soil rating (g.p.d./ft2 or ft2/bdrm) 1.0 System type WIDE TRENCH Length 63 ft. Width 5 ft. Gravel below pipe 4 ft. Total depth 12.8 ft. (Measured 9/28/18) Eff. absorption area 630 ft2 Monitoring tube Y Depression over field N Date of adequacy test 9/28/2018 Results (Pass/Fail) PASS For 4 bedrooms Fluid depth in absorption field before test 0 in. Water added 760 gal. New depth 0 in. Elapsed Time: 0 min. Final fluid depth 0 in. Absorption rate >= 600 g.p.d. Any rejuvenation treatment (past 12 mo.) (Y/N & type) N If yes, give date D. LIFT STATION Date installed Size in gallons Manhole/Access (Y/N) —_ "Pump on" level at in. "Pump off' level at in.High water alarm level at in. Datum Cycles tested Meets alarm &circuit requirements? E. SEPARATION DISTANCES WELL ON LOT TO: Septic tank/lift station on lot 100'+ On adjacent lots 100'+ Absorption field on lot 100'+ On adjacent lots 100'+ Public sewer main 75'+ Public sewer manhole/cleanout 100'+ Sewer/septic service line 25'+ Holding tank 100'+ Animal containment areas 50'+ _ Manure/animal excrete storage areas 100'+ SEPTIC/HOLDING TANK ON LOT TO: Building foundation'5'+ (PER IR ASB) Property line 10'+ Absorption field 5'+ Water main 10'+ Water service line 10'+ Surface water 100'+ Wells on adjacent lots 100'+ ABSORPTION FIELD ON LOT TO: Property line 10' Building foundation 10'+ Water main 10'+_._,___ Water Service line 10'+ Surface water_100'+ Driveway, parking/vehicle storage 10'+ Curtain drain 50'+(None Known) Wells on adjacent lots 100'+ F. COMMENTS I Y yPL CooLe- G. ENGINEER'S CERTIFICATION ��O F Az`1I I certify that I have determined through field inspections and .�1�;•• •: 1 review of Municipal records that the above systems are in / �?•• 4�� ••9 Pt conformance with MOA COSA guidelines in effect on this date. -*: 4 9TH ' • * d� Engineer's Printed Name MICHAEL N.ANDERSON,PE d .. / • MICHAEL N. ANDERSON :, Date 1010212018 r c-• CE-9469 • `� lPin- PR(2/�/'lc.�,,;�' 1400\a" COSA canary sheet_2-6-15.doc • agro •� 77 Municipality of Anchor • A °*4 �. On-Site Water and Wastewater Prog r b ` (907) 343-7904 201 s r r e r r JUL 14 30, ti Certificate of On-Site Systems At.. oval Parcel I.D. 017-013-36 Expiration`s 01-6 s 1. GENERAL INFORMATION Complete legal description Aspen Highlands #2, Block 2, Lot 9 Location (site address) 13001 Tracy Way Anchorage, AK 99516 Current Property owner(s) Casey & Zoe Smith Day phone 644-7949 Mailing address 13001 Tracy Way Anchorage, AK 99516 Real Estate Agent Day phone 2. TYPE OF DWELLING: 111 Single Family (w/wo ADU) ❑ Duplex ❑ Multiple Dwellings (Single Family and/or Duplex) 3. NUMBER OF BEDROOMS: 4 4. TYPE OF WATER SUPPLY: TYPE OF WASTEWATER DISPOSAL: Individual Well 0 Individual Individual Water Storage ❑ Holding Tank ❑ Community Class Well ❑ Community ❑ Public Water System ❑ Public Sewer ❑ WaiverNariance request for: Distance: Received by: Date: 5511/II COSA to be released to the engine unless otherwise requested by the engineer. COSA Fee $ 524, Waiver Fee $ Date of Payment fI (-4-(PE Date of Payment Receipt Number 0631-7o41e. Receipt Number COSA it 050 (V-c17 Waiver# 6. STATEMENT OF INSPECTION BY ENGINEER As certified bymyseal affixed�Ihereto and as of the validation date shown below, |verify that myinvestigation, based on procedures outlined in the Certificate of0n'Sbe Systems Approval Guidelines for this apphcetion, shows that the on-site water supply and/or wastewater disposal system is (one) eafe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and innpeotion, the on-site water supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal and State codes, ordinances, and regulations ineffect atthe time ofinstallation. Name ofFirm Anderson Engineering 139-----�����U�8��� Anchorage, AK 99503 Address ° "" 34th Ave, ' ~ Engineer's Printed Name Benjamin Schiller, P.E. 6. DSD SIGNATURE \/System #1Approved for _-L bedrooms System #2Approved for bedrooms Disapproved 773 Phone 522-7��`� Conditional approval for _ bedrooms, with the following stipulations: -_ WASTEWATEER :Z Original Certificate Date: The Municipality n/Anchorage Development Services Division (oGD)issues Certificates nrOn-Site Systems Approval VCOSa>based only upon the representations given in paragraph 5 by an independent professional civil engineer registered in the State of Alaska. The Municipality of Anchorage isnot responsible for errors momissions mthe professional engineer's work. 7. ATTACHMENTS: CO88Cheddkst X Nitrate Advisory Septio System Advisory �_ ArSeniC/\dvo0ry Well F|ovv'Advioory /` ^�Other _ _ If more than 1 septic system is on the lot: COSA Checklist # of Structure served by this system Certificate of On -Site Systems Approval Checklist Legal Description: Aspen Highlands #2, Block 2 Lot 9 Parcel ID: 017-013-36 A. WELL DATA Well type Private If A, B, or C provide PWS ID # Date completed 7/1 3/07 Sanitary seal (Y/N) Y Total depth 365 ft. Cased to 171 ft FROM WELL LOG Date of test 7/13/07 Static water level 205 ft. Well production 1 WATER SAMPLE RESULTS: Coliform N D colonies/10 Arsenic N D ug/L g.p.m. mL Nitrate 6.94 mg/L Date of sample: 6/30/17 B. SEPTIC/HOLDING TANK DATA Tank Type/Material Septic/Steel Tank size 1250 gal. Number of Compartments 2 Foundation cleanout (Y/N) Y Date of pumping 6/20/17 C. ABSORPTION FIELD DATA Well Log (Y/N) Y Wires properly protected (Y/N) Y Casing height (above ground) 19 in. AT INSPECTION 8/1/17 62.1 ft. 1.36 9 - p.m - Collected by: Anderson Eng. Date installed 10/26/07 Cleanouts (Y/N) Y Depression over tank (Y/N) N High water alarm (Y/N) N Pumper Isaac's Pumping Date installed 10/25/07 Soil rating (g.p.d./ft2 or ft2/bdrm) 1.0 gpd/sf System type 5' Wide Length 63 ft. Width 5.0 ft. Gravel below pipe 4.0 ft. Total depth 12.5 ft. Eff. absorption area 630 ft2 Monitoring tube Y Depression over field N Date of adequacy test 7/6/17 Results (Pass/Fail) PASS For 4 bedrooms Flu)d dep$h in. absorption field before test 0 in. Water added 600 gal. New depth 0 in. Elapsed'T.ime`:' min. Final fluid depth 0 in. Absorption rate >-600 g p d Any rejuvenation treatment (past 12 mo.) (Y/N & type) N If yes, give date D. LIFT STATION Date installed Size in gallons Manhole/Access (Y/N) "Pump on" level at in. "Pump off' level at in. High water alarm level at in. Datum Cycles tested Meets alarm&circuit requirements? E. SEPARATION DISTANCES WELL ON LOT TO: Septic tank/lift station on lot >100' On adjacent lots >100' Absorption field on lot >100' On adjacent lots >100' Public sewer main >75' Public sewer manhole/cleanout >100' Sewer/septic service line >25' Holding tank >75' Animal containment areas >50' Manure/animal excrete storage areas >100' SEPTIC/HOLDING TANK ON LOT TO: >5' >5' >5' Building foundation Property line Absorption field >10' >100'0 ' Water main >10' Water service line Surface water Wells on adjacent lots >100' ABSORPTION FIELD ON LOT TO: >10' >10' Property line >10' Building foundation Water main Water Service line >10Surface water >100 Driveway, parking/vehicle storage >10' Curtain drain None Noted Wells on adjacent lots >100' F. COMMENTS vgiblb*41%4 G. ENGINEER'S CERTIFICATION •" 5, air.g7 � 44 I certify that l have determined through field inspections and a •' -rte : .°%,-5"40review of Municipal records that the above systems are in sir►*• 4 c� '"' -5.•;'-,. ;' ..774. conformance with MOA COSA guidelines in effect on this date. si • •. <*O Engineer's Printed Name Benjamin Schiller, P.E. 4;41 S �•»• j+►min Jr ° . Date July 13, 2017C • % .d COSA brown sheet 10-10-12.doc Municipality of Anchorage Development Services Department 42 Building Safety Division '4k�t E T Y,,K On-Site Water and Wastewater Program 4700 Elmore Street P.O. Box 196650 Anchorage, AK 99519-6650 www.muni.org/onsite (907) 343-7904 I Certificate of On -Site Systems Approval # osc 171297 A Certificate of On -Site Systems Approval inspection and test of potable water was recently conducted on the well water supply on Block 2, Lot 9 of Aspen Heights #2 subdivision. This inspection revealed a nitrate concentration of 6.94 milligrams per liter (mg/L) was reported for the property's well water sample. The Environmental Protection Agency (EPA) has established a maximum contaminant level (MCL) of 10.0 mg/L for public drinking water systems. While private wells are not subject to this regulation, EPA standards are based on existing health information and can therefore be used to gauge the relative quality of water from private wells. Please see the attached "Nitrate Fact Sheet" for important information regarding nitrate. This advisory must be attached to all copies of the subject Certificate of On - Site Systems Approval. From Northern Testing Laboratories, Inc. Nitrate is a negatively charged compound of nitrogen and oxygen, which is very soluble in water. Nitrate is not readily filtered or otherwise removed in the soil and can pass rapidly into ground water wells. SOURCE: Nitrate is a major component of fertilizer and wastewater. Often the nitrate is in the form of ammonia or protein first, which through contact with oxygen and certain bacteria, converts to the oxidized form known as nitrate. Sources of nitrate from wastewater include urea, ammonia cleaners, food solids, and bacterial cells. It may also result from the breakdown of organic matter buried in the soil. TOXICITY: Nitrate is generally not toxic to adults or children over the age of two or three years, but is associated with a potentially fatal infant disease called methemoglobinemia. In the digestive system of young children, nitrate converts to nitrite, which can pass through the intestinal wall into the blood stream. There it combines with the hemoglobin and interferes with the ability of the blood to carry oxygen. For this reason, methemoglobinemia is referred to as "blue baby" disease. The EPA limits the concentration of nitrate in public drinking water supplies to 10 mg/L. The standard has been lowered from a previous level of 45 mg/L set by the US Public Health Service and the World Health Organization. TREATMENT: due to its solubility in water and negative ionic charge, filtration and other common home water treatment systems such as softening or iron filtration does not readily remove nitrate. The best method for limiting nitrate in well water is source control. This can include avoiding overdosing of fertilizer near the well and maintaining good separation distances between septic tank leach fields and the well. A special anion exchange filter that contains a media with a strong affinity for negatively charged ions in water, or by a reverse osmosis treatment system or distillation can remove nitrate. TESTING: Nitrate analysis is usually done by one of the several "wet chemical" methods using a spectrophotometer to read the final color endpoint. Specific ion electrodes also can be used to detect the activity of nitrate in water. This laboratory uses several different wet chemical methods approved under the public water supply laboratory certification program. They also have test kits available, which the laboratory uses to perform an inexpensive "screening test", and with which the homeowner can monitor the change in nitrate levels from their well. They recommend comparing the test kit results against a certified analysis from the lab occasionally to verify the accuracy of the kit. We recommend using a specially prepared bottle that has been rinsed in hydrochloric acid for collecting samples. • 'o. ,L ^ry -3• \i � °� LOT 7 0 14 14,0, LOT 10 \-10 `�%. IP �L o EHXISTING OUSE /' S62°4313644 0�fl \\ / \ /' ,ii.v.keekeo es, rry�• ,4*, � 2.2' 98, L1.0' ,6 �� 3 -° LOT 9 , ca — rt SCALE 1"=20' °. EXISTING �/ v BUILDING DETAIL •'`7r; C HOUSE - ~ coC0 ' o LOT 8 \ --"" o o �4AN 97.5' o) op/1 ‘...•""\\ --4- e41 b- ,-.)..-. :' 49— v Q // / T,, j4 SHED Vp STEVEN CALLAG AN Ar \\ o R^230.00' L=111.36' N81°00,00 Vv LLS/-120, 4 -- c OHO NOTE: lit 65.80' V Q��a '�<r �. a`'�O THIS DRAWING SHALL NOT BE MODIFIED FOR USE `. 40Ar0fessiono� ‘'°a AS A PLOT PLAN WITHOUT THE EXPRESSED — - --_____k�pOOOooa— WRITTEN CONSENT OF LCG LANTECH. \ _ _ — SCALE 1"=40' MIDORI DRIVE LEGAL 250 H Street DESCRIPTION: AS-BUILT Anchorage,Alaska 99501 ADDRESS: 13001 TRACY WAY PARCEL#:017-013-36-000 '"' .r ,( '--- LOT 9, BLOCK 2, SURVEY CERTIFICATION:LCG LANTECH,INC HAS CONDUCTED A PHYSICAL SURVEY OF Survey Department �+ A THE PROPERTY AS SHOWN ON THIS DRAWING AND CERTIFIES THAT THE Phone 562-5291 ASPEN HIGHLANDS NO. 2 SUBDIVISION - IMPROVEMENTS SITUATED THEREONARE WRHINTHE PROPERTYLNESAND NO LEGEND: ENCROACHMENTS EXIST OTHER THAN NOTED. t.BrhIne Mainline DRAWN DATE: 7/17/2017 WORK ORDER: 17061 ;::Aspholt: ?:;?: 6 Phone 243-8985 - — - -- — CLEAN OUT r rag EXCLUSIONARY NOTE:IT IS THE OWNERS RESPONSIBILITY TO DETERMINE THE a CA/Zedit 2e.• e Jineeu.,9 •buo,�ey<n9.. DRAWN BY: AP PLAT: 73-63 0 :. Concrete • EXISTENCE OF ANY EASEMENTS,COVENANTS,RESTRICTIONS OR RIGHT-OF-WAY WATER WELL - . . ••^ TAKINGS WHICH DO NOT APPEAR ON THE RECORDED SUBDIVISION FLAT. UNDER NO a� Overhang ac. s�i CHECKED BY: SC GRID: SW2840 _ FENCE —X—X— 9CIRCUMSTANCES SHOULD ANY DATA HEREON BE USED FOR CONSTRUCTION,FOR - Wood Decker ESTABLISHING PROPERTY LINES,OR FOR PLOT-PLAN PURPOSES. ORDERED BY: CASEY&ZOE SMITH SCALE: AS NOTED FB/PG:68/32 - J l� w Municipality of Anchorage Development Services Department •° !� Building Safety Division �= On -Site Water and Wastewater Program 4700 Elmore Road P.O. Box 196650 Anchorage, AK 99507 www.muni.org/onsite (907) 343-7904 CERTIFICATE OF ON-SITE SYSTEMS APPROVAL FOR A SINGLE FAMILY DWELLING y Parcel I.D. o"7 -013 -$ of COSA# bsoa7r I. GENERAL INFORMATION Expiration Date: S - _-a %— Q f� Complete legal description Lot 9, Block z AsPen wghlanas subdMrJon No. 2 Location (Site address) 13001 Tracy way Andxwage, AK 99s18 Current Property owner(s) Edo and T zcyTmj"Ck 951-103-73s9Day phone Mailing address 39791 Links court Temewla, CA 92591 Lending agency Day phone Mailing address Real Estate Agent Day phone, Mailing Address Unless otherwise requested, COSA wX be held by DSD for pickup. 2. NUMBER OF BEDROOMS: Four (4) 3. TYPE OF WATER SUPPLY. Individual Well 0 Individual Water Storage El Community Class Well El Public Water System 0 TYPE OF WASTEWATER DISPOSAL: Individual On-site _0 Individual Holding Tank 11 Community On-site 0 Public Sewer 0 The Municipalif of Anchorage Development Services Department (DSD) issues Certificates of On -Site Systems Approval (COS.--) based only upon the representations given in paragraph 4 by an independent professional civil engineer registered in the State of Alaska. Certificates of On-Slte Systems Approval are required for the transfer of title (except between spouses) for properties served by a single-family on-site wastewater disposal and/or water supply system. DSD also issues COSAs upon request to homeowners. Certificates of Onsite Systems Approval are valid for 90 days from the date of issue for properties served by a private or Class C well and may be reissued with new water sample results. (Certificates may be reissued for a period of up to one year with valid water samples.) Certificates are valid for one year for properties served by Class A or B wells or a public water system. The Municipality of Anchorage Is not responsible for errors or omissions in the professional engineer's work. 4. STATEMENT OF INSPECTION BY ENGINEER As certified by rry seal affixed hereto and as of the validation date shown below. I verify that my investigation, based on procedures outlined in the Certificate of OnSfte Systems Approval Guidelines for this application, shows that the on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-sile water supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal and State codes, ordinances; and regulations in effect at the time of installation. Name of Finn Anderson Engineering Address P.O. Box 240773 Anchorage, AK 99524 Engineer's Printed Name Michael E. Anderson, P.E. Phone 522-77r3 Date =12008 0 ve : miCKAn t ANDERSON; .t. 6. DSD SIGNATURE ��`��g, CE -4381 vl�Approved for _4 bedrooms. ,+1?�Fa�: Z; goo Nom.44P �j PlAr ecffi � o Disapproved. Conditional approval for bedrooms, with the following stipulations: ONSITE Attachments: COSA Checklist X Septic System Advisory Well Flow Advisory Nitrate Advisory X Arsenic Advisory Maintenance Agreements Supplemental Engineer's Report Other By, Original Certificate Date: (RN 11X5) Municipality of Anchorage Development Services Department Building Safety Division On -Site Water & Wastewater Program • • .. 4700 Elmore Road P.O. Box 196650 Anchorage, AK 99507 www.rnuni.org/onsite (907) 343-7904 CERTIFICATE OF ON-SITE SYSTEMS APPROVAL CHECKLIST Legal Description: Lot 9, Block 2. Aspen Highlands No 2 Parcel ID: 017-013-36 A. WELL DATA Well type PrHate If A, B, or C provide PWSID # __ Well Log (Y/N) Y Date completed 7/13107 SanitaryY seal _ Wires property protected (YM) Y Total depth 365 R Cased to 171g_ Casing height (above ground) >16 in. FROM WELL LOG AT INSPECTION Date of test 7113=07 ' Static water level 205 ft ft Well production 1 9.p -m., g.p.m. WATER SAMPLE RESULTS: C.OlifOrm O colonies/100mL Nitrate 6.46 mg/L Other bacteria 3 colonies/100 mL Arsenic: NM ug/I Date of sample: ti14108 Collected by: A Harala B. SEPTIC/HOLDING TANK DATA Tank Type/Material SeptkJsteel Date installed 10/15107 Tank size 1.250 gal Number of Compartments Two Cleanouts (YRJ) Y Foundation cleanout (Y/N) Y Depression over tank (Y/N) N High water alarm (YM) N Date of pumping New' Construction Pumper C. ABSORPTION FIELD DATA Date installed 10r2W7 Soil rating (g.p.d./ft2 or ftz/bdrm) 1.0 GPD/SF System type s•WWesnano.,7md, Length 63 1 fL Width 5 ft.' Gravel below pipe 4 ft. Total depth 11 R Eff. absorption area 630 ft2 Monftoring tube Y Depression over field N Date of adequacy test New Const. Results (Pass/Faio For _bedrooms Fluid depth in absorption field before test in. Water added gal. New depth in. Elapsed Time: min. Final fluid depth in. Absorption rate >= g.p.d. Any rejuvenation treatment (past 12 mo.) (YM & type) N If yes, give date D. UFT STATION Date installed Size in gallons Manhole/Access (YIN) 'Pump on' level at _in. 'Pump air level at_ in. High water alar level at In. Datum Cycles tested Meets alarm 8 circuit requirements4 E. SEPARATION DISTANCES SEPARATION DISTANCES FROM WELL ON LOT TO: Septic tank/lift station on lot >1D(' On adjacent lots >100' Absorption field on lot >1D0' On adjacent lots >100• Public sewer main WA Public sewer manhole/cleanout wA Sewer/septic service line >25' Holding tank N/A Animal containment areas None Manure/animal excrete storage areas None SEPARATION DISTANCES FROM SEPTICIHOLDING TANK ON LOT TO: >s P line >s Building foundation �rtY Absorption field >s Water main NIA Water service line >10' Surface water >100' Wells on adjacent lots >100' SEPARATION DISTANCE FROM ABSORPTION FIELD ON LOTTO: Property line >t0' Building foundation >10' Water main >10' Water Service fine >10' Surface water >100' Driveway, parking/vehicle storage >26 Curtain drain None tooted Wells on adjacent lots >1�' F. COMMENTS: G. ENGINEER'S CERTIFICATION I certify that I have determined through field inspections and review of Municipal records that the above systems are in conformance with MOA COSA guidelines in effect on this date. Engineer's Printed Name Michael E. Anderson. P.E. Date ?119/2008 COSA Fee S f);/- Waiver Fee $ _ Date of Payment � CkS' Date of Payment Receipt Number Receipt Number (Rev. 111W 10*L'6 ANDERSON :,4 F, CE -4381 4, A. OD OD n � d N W J F N Q Ir Uw z ,^ U) K U O z co _J F � O °' J 96'9bl S -00,00.60N o / G y oc co co 3�1 lu / i' 0 0 0 °F 0 i o 000 Q o O 0 ^b' U 02 OZS 0. est S av s� o. \ s O0, �SZ \\ Cl) Obl O r p O� \� m 5• 1 ►CD I M i � � I � 1 S. T- d 1 1 0 Oe) 00 o mZ 1 1 I I 1 1 / 1 a•1 I °/ 000°� y / pati 4 �G °O 9 N OI 0. of r 0 .n LL z d �w o F . 0 oWLx o� �C� o�o �N0Z z=w w N K 7w< F �=a SGS WEN 1080621001 Client Name Anderson Engineering Project Name/# L9 B2 Aspen highlands Client Sample ID f louse Exterior I lose Bib lltatrix Drinking Water PWSID 0 SMDIC Remarks: All Dateerimes are Alaska Standard Time Printed Dalefrime 02/222008 16:00 Collected Dalcrfime 02/142008 14.30 Received Dsicrrime 02/142008 17:05 Technical Director SlcPhen C. Ede Parameter ResultsAllowable Prep Analysis POL Units Method Container ID Limits Date Date Init Metals by ICP/ms Arsenic ND 5.00 ug/L EP200.8 C (<IO) 02/19/08 07120/08 NRB Waters Department Total Nitrate/Nitritc-N 6.46 Microbiology Laboratory Colony Count 3 Total Colirorm 0 Fecal Coliform 0 0.100 mg/L SM204500NO3-F B (<to) eoVI00mL SM209222D cuV100mL SM209222B CDUl00mL SM209222B A (<200) A (<1) A (<I) 0221/08 LCP 02/14/08 SDP 02/14/08 SDP 02/14/08 SDP Municipality of Anchorage _ I Development Services Department !� Building g SafetyDivision On -Site Water and Wastewater Program 4700 Elmore Street P.O. Box 196650 Anchorage, AK 99519-6650 www.muni.org/onsite (907)343-7904 Nitrate Advisory Certificate of On -Site Systems Approval # 080037 A Certificate of On -Site Systems Approval inspection and test of potable water was recently conducted on the well water supply on Block 2, Lot 9 of Aspen Highlands No. 2 subdivision. This inspection revealed a nitrate concentration of 6.46 milligrams per liter (mg/L) was reported for the property's well water sample. The Environmental Protection Agency (EPA) has established a maximum contaminant level (MCL) of 10.0 mg/L for public drinking water systems. While private wells are not subject to this regulation, EPA standards are based on existing health information and can therefore be used to gauge the relative quality of water from private wells. Please see the attached "Nitrate Fact Sheet" for important information regarding nitrate. This advisory must be attached to all copies of the subject Certificate of On - Site Systems Approval.