Loading...
HomeMy WebLinkAboutSCIMITAR #2 BLK 3 LT 20Scimitar #2 Block 3 Lot 20 #051-132-58 .;� Municipality of Anchorage Development Services Department Building Safety Division On-Site Water and Wastewater Program, 4700 Bragaw St. P.O. Box 196650 Anchorage, AK 99519-6550 Page / of 3 www.ci.anchorage ak.us (907) 343.7904 ON-SITE WASTEWATER DISPOSAL SYSTEM AND/OR WELL INSPECTION REPORT Permit Number. Lcoo PID Number: 5 / //32'-54 Name o Wastewater System: XNew El Upgrade n Aayress /U7 S G S'P O 7 ABSORPTION FIELD N,+nLer of Beba.na� s P�DsaP Tr«r/t O SNllpn Trsron D Bao D MauM Q pnyr LEGAL DESCRIPTION Sag Rr"0 Taai Dawn hen w9ral praye Bbdt La c 5�{-P-vra0n J 3 �O SCM/I C. GPDIF2 DsPth to pPa Dw tp it= ma"^�LL ¢+a• J. FI. Ft. rrSM Oaph be,48th PJs T°"nsno Randa sedan F• gysa mora onyn« ¢aye Ft Gray« Lanp.n �L.. Ft. 47 FI. Well:New ElUpgrade Gam nh Nu ba eines Dmianot Os wean ling, FL FL Cusvi,� (pours, Total Depen Cassa a a 3 QQ fl. Op Ta« morphon«aa 0 P,pr M 'e FI F1 3G Orw«c Drr. D'~ Static Wit« L@•N J0 / //'7 �7 ZQ Ft In{,a ��� �R `jJ U Data lnatL�//�/� �] Y412 Pura s« rCivrp 1MT Aw Grarry Z8 � 3e TANK I GPM FI. ^_ SEPARATION DISTANCES Pteptic ❑ Holding ❑ S.T.E P. ❑ Other. To Septic Absorption Lift Holding ubIWPnvate °01.wA aw tv Prom Tank Field Station Tank Sewer Line 4/ OR eE 74 /.SQO Gr wad 10111 f Of MaloM � ���� NU o�prparinunls z sunrw Wr« QQ r f l46 �F _ _ LIFT STATION La Lae SO ,', l0 /.�• � `• nuaa.a« n r In Cunaa Drrn Punp Moe Elect," nspacban perlornrea Ram s M. ✓r JfL ccs ro BENCH MARK S �� Location ane Dewaaon S l l rN, ar f !� 8 JUE G'oods}GL A.%o� Fr; /d Inspections performed b A INK J6,013 - Dates: 1r % / 2 �7 P P y: O r c.tia. Engin�'0 � �1t «, 2nd-2/1-3/0-7��P�• ••.«..a•.a4��ir Development Department P P Approval pry: �� '•;9 ,� fS.�.Ll ? 0 0.Conditional Approval Date: Ma•••a• •• •• d ' .t r ; S!evan W. Eno.. •�;`� �d J•J, :•• PF 46456 V:" �^F rare. Reviewed and approved by: / �� ate: Cr (Rev 04 b), C ,. •; <}'r �atCyatbaF'v [Neighbor Water Well Drill d , Wat r Well 5 BERM Home,,,' RECORD DW7MEASUREMENTS SCIMITAR #2 S/D BLOCK 3 LOT 20 ._ 1 40' RECORD PO Sox 770724 it (•s,..'••• • Eagle River, Alaska 99377 ••.• a-�m°gi : •'� 907.694.7028 ® DRAWING A e: 4/25/08 FCO 25 4 ST C01 STCO2 25 29 15 25 DCO 35 32 co 1 44 29 CO 2/MT 93 89 Site TH2 Double CO's 500 Gallon Septic v Slope < 10% Septic System Construction Does Not Preclude Adjoining Lots From Sanitation Improvements. X16 , NORTHRIM ENGINEERING ''49 SCIMITAR #2 S/D BLOCK 3 LOT 20 ._ 1 40' RECORD PO Sox 770724 it (•s,..'••• • Eagle River, Alaska 99377 ••.• a-�m°gi : •'� 907.694.7028 ® DRAWING SEPTIC SYSTEM e: 4/25/08 -- 2 of 3 i a A o M .� 2Z d ri n { O N + M Z O D £ o O m fel Z Z N d 'D U v V ~ M � :pQ 0 A o M iM d ri n Z C M Z O D £ Z fel Z Z N d 'D t7 rl f- r ~ M � m .A NtO 0 A o r n 3 iM W �7 ri C M Z O N ', N N d 0 l:7 D UI 3 0O n 3L1 O P P O (O 3 3 rri Q W I Y l'♦Ii�'1%i � i O 3 >Z 1 0 0 3 h O --I Z N 3 n s O V 0 O tn3 (O A 3 0 h N w N h F N N 3 H 0 V C+ n P 3 77 w Z (D 3 A S P 3 D iM .O C Z O N ', N x h0 VI 9-0 3 � 0 O N -I n 3 3 A 0 f•1 P Lt 3 3 p 3 A 11 h �D O .h a 3 n 3 O Z A N r, D 3 N r) < v A �* r, 3 m II n p W`+ h OS <O T Ln 3 tf II N �D 3 UP ,a 1 O l:7 D UI 3 0O n 3L1 O P P O (O 3 3 rri Q W I Y l'♦Ii�'1%i � i O 3 >Z 1 0 0 3 h O --I Z N 3 n s O V 0 O tn3 (O A 3 0 h N w N h F N N 3 H 0 V C+ n P 3 77 w Z (D 3 A S P 3 SOILS LOG - PERCOLATION TEST Date Performed: 9/11/07 Performed For: Troy Davis (Tim) Legal Description: Scimitar #2 Subdivision, Block 3, Lot 20 DEPTH (FEET) 1 - 2 - 3 - 4- 5- 6 - 7 - 8 - 9 - 10 - 11 - 12 - 13 - 14 - 15 - 16 - 17 - 18 - 19 - 20 - 21 - Organic TH2 Location See Attached Design GP Sandy Gravel w/ Low Silt Groundwater? No Depth -- Water Depth After Monitorinn.NonP nn+Pi # Date Gross Time Net Time Depth lNet Drop 1 9/11 0 -- 4' -- 2 9/11 10 10 mir, 9' 5' 3 9/11 40 -- 4' -- 4 9/11 50 10 mirl. 9' 5' 5 9/11 80 -- 1 4' -- 6 9/11 90 10 mid. 9' 5' Percolation Rate 2 min./inch Perc Hole Diameter 6' Test Run Between 4' and 5' Commentsi Performed By Northpim Fng, I CERTIFY THAT THIS TEST WAS Performed in Accordance with All State/Municipal Guidelines in Effect ON THIS DATE. DATE, 9/11/07 �'++WAU OF NORTHRIM E ENGINEERING * "49m ` • TESTHOLE LOG T. H. 2 PO Box 770724 . Eogls Rive , Alaska 99377 ' •, vo; 907.694.7028 ...... •" GE❑TECHNICAL-. 9/11/07 12 DE: FP31 : FFati M : Apr. 28 2W9 11:41PH Pl Development Services Department Building Safety Division ra "` On -Site Water d Wastewater Program •'•• s` ` 4700 Bra9aw Street = P.O. Box 196650 tfark epM Ancbero9e, AK 997196650 a• 'r' Atary L�++x.A.+•Lery*M, 1e (90?) so -1'904 F.'x 3 v3 - 71l'7 Pump Installation Log Well Drilling Permit Number: SW-PLOII -073/ I Parse! Identification Number:— 1073 U/,4xy SC/,r"/TAR !}, Pump Installation Date: a .- 7—,P 17 Date or Issue: ,12 9/o g rperty Ow aer sau & Addrtsu J"Rey PRY/5 9e^,F%s /07.r GyE6,r S7 STs'• /s7 /dAS/6,(N ; 4 y y 6s't' Pamp Intake Dcptb Bsloss Top of Well Casing: fat a 8 (o r i t � Pump lfaoufactarer's Name. G O v 6 OS Pumpllodch 7 SB /V Pump Size / by r 0 PidessAdapter Burial Depth: /Y 1 feet Pidess Adapter hfanufacturrr's Name: /3 / 0 ?(- C .4 Mf SfLL PsuessAdapter Insulter: f/SgNO ts'eU Disinfected Upon Comp1etiont7,Yes [3,N0 Afetbod oMsioleetloat C L.#R iiae TAOI <7-S Commeats: Pomp Insurer Name: CangwnyN'sme Ov,C11"o/z �/i^Ig i l./tiL 1lleilingAM-err A9 Ciry AK zir 1.i,9S/GL,st� /f�C yy G r y Aruction: The pvsp lrcullcr shall provide a p::rcp installation log to the DSD within 30 days of pump installation. Apr 15 08 02:33p TROY DAVIS HOMES 15073579395 p,1 Certitieborf aing `-Log by ox co. d:. SULLIVAN WATER WELLS P.O. BOX 670272, CHUGIAK, ALASKA 09587 -TELEPHONE 688-2759 OWNER OF LAND:: ;: `+ "f S It's ✓ti C S ADDRESS: LEGAL DESCRIPTION: P/i- _2 E47 a C1 i DATE PERM.T NLIMSB R: f:: J r £ Date of issue=- r — _I3 TAX ICENTIFICATION NUMBER: QT1 -3A_ Is well located at apptoyed permit locaboo? ] Yes i] No Method of Drillinc: G-0 rotary 7 cable tool Depth of well: `- 'a C Casing Type Lyall Thickness ��' inches Diameter Inches, depth feet Liner Type: -Z Casing Stickup Above Ground -IQ feet Static Water Level: F feet Recover Rate: gpm Method of Testing:` , 1; -- Well Intake Open ng Type: O open end 6,crp n hole Zi Screened: Start feet Stopped feet O Perforations Start feet Stopped feet Grout Type'l • _ i _ Vclume Depttx from % feet, to feet NkII Disinfected Upon Completion? trSes 7 No Method of Disinfectinn: �L .:•.. `iU i �• �� Comments: I Driller's Name __C n � �= S ..f � � • �"^• ATTENTION: It IS the responsibility of the property owner to Submit a copy of the well log to the proper authority. Municipality Of Anchorage: Department of Health & Human Services and/or Department of Environmental Conservation.. MatSu Borough: Department of Environmental Conservation. C`�rJ r•._ L_ S� iLR/''- t7Kr�C� .mac ;rS Sr..�.�rs — I f 3rd: e•� I Driller's Name __C n � �= S ..f � � • �"^• ATTENTION: It IS the responsibility of the property owner to Submit a copy of the well log to the proper authority. Municipality Of Anchorage: Department of Health & Human Services and/or Department of Environmental Conservation.. MatSu Borough: Department of Environmental Conservation. MUNICIPALITY OF ANCHOR4GE Development Services Department On -Site Water d Wastewater Program J/ �j I aj) 4700 South Bragaw Street P.O. Box 196650, Anchorage, AK 99519.6650 (907) 343-7904 ON-SITE WASTEWATER DISPOSAL SYSTEM / WATER SUPPLY PERMIT Initial Permit Number: SW070168 Legal Description: SCIMITAR #2 BLOCK 3 LOT 20 Design Engineer: 0838 NORTH RIM ENGINEERING Owner Name: TROY DAVID Owner Address: 1075 CHECK STREET #207 WASILLA , AK 99654 - Date Issued: Jul 19, 2007 Expiration Date: Jul 18, 2008 Parcel ID: 051-132-58 Site Address: NHN TOLWAR DRIVE Lot Size: 43326 SO, FT. Total Bedrooms: 4 Permit Bedrooms: 4 This permit Is for the construction of: 0 Disposal Field E✓ Septic Tank Ej Holding Tank F] Privy Q Private Well E] Water Storage All construction must be in accordance with: 1. The attached approved design. 2. All requirements specified In Anchorage Municipal Code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72 ) and Drinking Water Regulations (18AAC80 ). 3. The engineer must notify DSD at least 2 hours prior to each Inspection. Provide notification by calling (907) 343-7904 ( 24 hours ). ( Not required for a Water Supply Permit only ). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must be either: A. Open and closed on the same day. B. Covered, sealed, and heated to prevent freezing. 9-31-07 I11 IO"I r Received Issued By. II1'I1 Ca. 11 -cel WCliv:'1_s -t` MOvZ_ weiX -/. / '✓/ wCsY Cev*ftyp IV -t, �C7Cf /nt-45SA9•- 4V[/L SYe' ✓L p YXcA Jct new/ %N. loo+fio,•. new / Pes,J4 C'44 jcD 506,­Trc7 11 +0 Date: --7/.2 Date: i IY Municipality of Anchorage ❑ - :—Development Servlpe!,Department- ❑ Building Safety Division •; '�'" On -Site Water and Wastewater Program ❑ 4700 Bragaw Street P.O. Box 196650 ❑ Anchorage, AK 99519-6650 www.muni.orglonsite (907)343-7904 ON-SITE SEPTIC/WELL PERMIT APPLICATION FOR A SINGLE FAMILY DWELLING Parcel I.D. 6S/- /3A- 5R Propert Mailing y owners) Da hone z S-7 9's 97 • / y p address Zip Code 9 S� Site address g l -,w -ML AjAQ-ff Zip Code Legal description (Sub'd, Block & Lot) Legal description (Township, Section & Range) Lot Size '-/3. ,3 Sq. Ft. THIS APPLICATION IS FOR (®all that apply): Absorption Field ❑ Septic Tank ❑ Holding Tank ❑ Privy ❑ Private Well Water Storage ❑ Number of Bedrooms 4 THIS APPLICATION IS AN: Initial ❑ Upgrade ❑ Renewal ❑ I certify that the above information is correct. I further certify that this application is being made for a Single Family Dwelling and is in accordance with applicable Municipal Codes. / A 9 (Signature of property owner or aL*ihorized agent) Permit/Rush Fees: Waiver Fees: Date of Payment: '4h & I D y. Date of Payment: Receipt Number: I!M5_8 Receipt Number: (Rev. 11/05) ab all . .�TVLr rb T Wn-INEERING NorthRim Engineering PO Box 770724 Eagle River, AK 99577 907.694-7028 July 13, 2007 MOA On -Site Water & Wastewater Program 4700 Bragaw St Anchorage, AK 99519 RE: Scimitar #2 S/D, Block 3, Lot 20 A lot is being developed. Excellent soil was found. The design is based on this test hole. Private water wells serve the subdivision. The neighboring lots are mostly developed. No conflicts exist to other on -lot systems. This site should not negatively impact any of the other area lots. The lot slopes to the north & is less than 10%. Please review the wastewater system design for the single family home. I have included design plans & specs, design guidelines, & soil tests. If there is need for additional information or clarification please give me a call. Sincerely `-9ttve Eng, PE, PH Design Enclosures `f 1 ZGIZGWERING Scimitar #2 S/D, Block 3, Lot 20 SPECIFICATIONS & DESIGN GIJIDF,LINF.S Wastewater System Sizing: This is a new 4 -bedroom, single family home. This is an older subdivision and most of the neighboring lots are developed. These lots are large and are served by private water wells. No adverse impacts are expected from development. No conflicts to the other lots will take place by this septic system and water well construction. The easements are located on the drawing and are not encroached upon. Soil tests revealed sandy gravel soil with low silt. An application rate of 1.2 GPD/FT2 with 0.5 reduction factor for utilizing a 5' wide trench. Trench Length = 500 FT=/5'x .5 reduction factor = 50'; 1 line @ 50'. No bedrock was encountered or groundwater was encountered. Specification Requirements: All components and work must comply with the Municipality of Anchorage Specifications (AMC) & State of Alaska Drinking Water Regulations and Wastewater Regulations. • Two compartment, 1250 gallon septic tank. Watertight couplings on inlet & outlet. • 5' minimum between the tank and bed. 10' to property lines. • 3' of cover or insulation is required for trench; an equivalent of 1" insulation for each foot soil cover. • Tank & solid pipe must be set on well compacted, stable soil. • 4 inch diameter cleanouts with airtight caps are required V to 4' from foundation wall, prior to any 90 degree bend in 4 inch line, in each tank compartment, and two adjacent opposing cleanouts between the tank and the absorption field, not more than 10' from the tank positioned to provide cleanout access towards the tank and towards the absorption field. • All cleanouts must extend to at least ground level. • In solid pipe runs, ASTM D-3034 may be used in lieu of cast iron. • Trench to be placed level, minimum of 4' to groundwater, 6' to bedrock from drain - rock. • Drain rock to be %= inch to 2 %: inch screened. Drain rock to be distributed uniformly throughout the trench. • Perforated pipe to be installed level with perforations down. • Silt barrier (filter fabric) to be installed above the drain rock. • Smeared trench sides must be raked or scarified before drain rock placement. • Backfill over drain rock must not be less than 36". • The finish grade must be mounded to promote drainage over the trench. • Insulation must be placed over any pipe installed under driveways or parking areas. • Approved pipe materials include cast iron, PVC ASTM D3034, PVC ASTM F789, ABS ASTM D2661, • Sewer Service Line is minimum 2% slope. • Septic Tank to be pumped every two years or when required. 9 Insulation board to be extruded direct burial polystyrene (Dow Styrofoam III/equal) Septic System Construction Does Not Preclude Adjoining Lots From Sanitation Improvements. TH M'T' 1 Rerve Site ,_—Alosorp Ion Trench \ \Double C.O.'s \ 1250 Gallon Septic Tan Slope < 10% F.C.O. New 4 BDRM Home Driveway M Proposed Water Wel DESIGN NO 1. Total De of Trench is 8'. es South. er Service Line minimum 2% slope. 3. Test Hole Log Attached. 4. Lots Served by Private Water Wells. 1• = ao �.°F NORTHRIM '' SCIMITAR #2 S/D ENGINEERING *.�s �� BLOCK 3 LOT 20 PLAN PO &am 770722. :: ;; o.. ;:: LAYOUT Eagle RlH . Alaska 99377 •. a-ws 907.694.7028 ......SEPTIC SYSTEM`7MV07 1 of 4 Gam, rw � on Of 00'S9 .i L.20C.39 /� w O h 41 \ ., Ilk S N (' ` Z` OL v o. r(2 ° o, r0 9C Sic r\ u u 0m d m/n \\, H Y I,o a u O U I M �O� O C �F. Ov :9 ICE 0 4 }. C z u r<C I P CWY u j yI P}� CC[CL C 01 YL C ^ _ CL E ., L.z 3.•co.a.00r 1... T4' 0 C ].00N ` n r u Z 1� > F00. " Y N N L C 00`1 CS awYn NAJ.-C. a' d I 0 N 0 o_ O N A N N H 0 N J u y� N Y.- M H Y n U CD �-1 O J � N A Ln Z 0 W A W Z H ¢ ¢ J W Q F- ¢ �/� V/ W 3 a IIS � a h A IW nIR IOW (q O � LL, 0 o Lo v °a 3 O O L F_ co N S F OLc7 L 40 C L £ O A N in c a V p F- 0 Oj J u ++ W c lu V) + ss r Q (') H a a ~ O CD m U J v w > N Pa N +. rl 3 w 0 4 c `` Z a, wW LD v a 3 J Cl)a u � LL LLI vii 0 a i A a y CL U > 0 Z W 0 E U s0 Cl W z U u = Q >- F- 0 a U ~ (� Z u O >, F— F— w Y o 2 +' 3 w e a W. o W W CGi L N� GN a) aN N N s W C > Cd 0 3 3 L 0 y�•�yy..,_ U U78 O L w '0 c i C$ Y +'3 1.70 0 i 0 c t� vLi ii c °D a L u ms E w L cu<N-0� Oi CN L a 11�•. Os 3 •fO UNL JOO� 111,15«•. O £e6 L- dUi-'U tn U +' n y U O LSH OLi `� ,1a U w Oy N mU E �? Na F_ 4. F- (,0)F- a, Y w n m C E7 0 d 1 CIL L 0 2 U� L Ly O• =llJ n a n +• *'cam° 3 v �W <m o L3 a O.+. 3 d a) Z o vi a0 cn3cn¢� �� m � m L0 \\ a acv rivLO� ZW a° W$ § cu t \} 0 L \¢ $(} CjL, 75 k\+ �{J co C }), _C5-! tet: ALS: -C 0 §)rp, M E_CI ) zQ§] LO 0, L- emeV § _; (XJw. � � K - .; wt. - .;� � � �; � % • .���. .!� # •ice # � �% _ • |� - |� ' J •ice K . •;i i - ,� •;i i e► a •;i i ` ■ ��� e S❑ILS LOG - PERC❑LATI❑N TEST Date Performed: 3/9/07 Performed For: Troy Davis (Tim) Legal Description: Scimitar #2 Subdivision, Block 3, Lot 20 DEPTH (FEET) Organic GP Sandy Gravel w/ Low Silt T.H. Location: See Attached Design Groundwater? No Depth -- Water Depth Ar+or Mnnitnrinn.NnnP Date: 3/28/07 & 5/15/07 # Date Gross Time Net Time 2 Net Drop 3 - 3/9 0 -- 7' -- 2 r: 5 - 2 Min 7 -• 1' 3 3/9 8 - -- 8' -- 9 3/9 10 2 Min 9' 1' 11 _ ;:....N ;... 64 -- 13 - '•• 14 - 3/9 15 - 2 min 16 - 1' 17 - 18 - 19 - 20 - 21 - Organic GP Sandy Gravel w/ Low Silt T.H. Location: See Attached Design Groundwater? No Depth -- Water Depth Ar+or Mnnitnrinn.NnnP Date: 3/28/07 & 5/15/07 # Date Gross Time Net Time Depth Net Drop 1 3/9 0 -- 7' -- 2 3/9 2 2 Min 8' 1' 3 3/9 32 -- 8' -- 4 3/9 1 34 2 Min 9' 1' 5 3/9 64 -- 8' -- 6 3/9 66 2 min 9' 1' Percolation Rate 2 min./inch Perc Hole Diameter 6' Test Run Between 4' and 5' Comments, PrPsnaked Performed By NnrthRim Fng, I C Performed in Accordance with All ON THIS DATE. DATE: 5/15/07 _ CERTIFY THAT THIS TEST WAS State/Municipal Guidelines in Effect NORTHRIM:~P�iem ; * ENGINEERING •• ......•• TESTH❑LE LOG T. H. L PO Box 770724a........ Cagle Rl~. Alaska 99377 •. arr�.;'� 907.694.7026 •••.. GE❑TECHNICAL •� T. 7/13/07 1 DE: MUNICIPALITY OF ANCHORAGE Development Services Department p p Phone: 907-343-7904 On -Site Water & Wastewater Section Fax: 907-343-7997 Certificate of On -Site Systems Approval Parcel I.D. 051-132-58 1. GENERAL INFORMATION Expiration Date: / r/ t- 2 0 Z Z Complete legal description Scimitar #2 Sub, Block 3 Lot 20 Location (site address) 20394 TUlwar Dr, Chugiak, AK 99567 Current property owner(s) Griffin Rowdy C & Laura M Day phone 907)632-7353 Mailing address PO Box 770075, Eagle River, AK 99577 Real estate agent Brandi Sullivan 2. TYPE OF DWELLING: Q Single Family (w/wo ADU) ❑ Duplex ❑ Multiple Dwellings (Single Family and/or Duplex) Day phone (907)232-9504 3. NUMBER OF BEDROOMS: 5 4. TYPE OF WATER SUPPLY: TYPE OF WASTEWATER DISPOSAL: Private Well 9 Private Septic 0 Water Storage ❑ Holding Tank ❑ Community Well ❑ Community ❑ Public Water System ❑ Public Sewer ❑ Waiver request for: Distance: Received by: COSA to be released to the engineer, unless otherwise requested by the engineer. COSA Fee $ 550 Date of Payment Receipt Number OgD17ID COSA# 5c21158(-, Date: Waiver Fee $ Date of Payment Receipt Number Waiver # 5. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based on procedures outlined in the Certificate of On -Site Systems Approval Guidelines for this application, shows that the on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is (are) in compliance with all applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation. I acknowledge that On -Site staff may visit the site to verify the information submitted. Name of Firm Forge Engineering Phone (907) 522-7773 Address 1399 W. 34th Ave Suite 101, Anchorage, AK 99503 Engineer's Printed Name Benjamin Schiller, P.E. Date 9/22/21 :9� 1 TH / •� . 6. DSD SIGNATURE • • • •- System #1 Approved for 5 bedrooms eenjamr ,nvSchiller System #2 Approved for bedrooms��`��� •• CE 12592 •'��,: � l 9/22/21 ' •v��� Disapproved ,l�iF�PRO FE sl64,1 Conditional approval for bedrooms, with the following stipulations: OF AjV6( WATER AND o WAST'_V` o M NT 1� Original Certificate Date: The Municipality of Anchorage Development Services Division (DSD) issues Certificates of On -Site Systems Approval (COSA) based only upon the representations given in paragraph 5 by an independent professional civil engineer registered in the State of Alaska. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. 7. ATTACHMENTS: COSA Checklist X Nitrate Advisory Septic System Advisory Arsenic Advisory Well Flow Advisory Other COSA Checklist blue sheet Legal Description: Scimitar Sub, #2 Block 3 Lot 20 If more than 1 septic system on lot: COSA Checklist # of A. WELL DATA ❑Q Well log is filed with Onsite (or attached) Date drilled 7/19/07 Total depth 300 ft Cased to 100 ft Fm_1 Sanitary seal is functioning correctly Fm] Wires are properly protected Casing height (above ground) 26 in. Date of flow test for COSA 9/20/21 Static water level at beginning of test 196 ft. Comments B. TANK DATA Age of tank(s) 14 years Tank type/material Septic/Steel Measured operating fluid level in septic tank 50 [JE -1 Standpipes/foundation cleanout per record drawing Date of pumping Sanitary Pumpers 10/6/21 D. ABSORPTION FIELD DATA Deep Trench Which system tested (date installed) 9/13/07 R ALL standpipes present per record drawing Total measured depth from grade 9.4 ft (max) Measured depth to pipe invert from grade 4.9 ft (min) ❑ N/A — pressurized field 0 Monitor tubes go to bottom of effective. If not, state depth into effective Fil Code -required soil cover over field ❑ System presoaked (Required if vacant for greater than 30 days prior to date of test) Gallons introduced gallons Comments/Deficiencies: All stand pipes present per inspection report. COSA Checklist yellow sheet Parcel ID: 051-132-58 Structure served by this system Well production at time of test 5.3 gpm Water storage tank volume gallons Well disinfected for coliform test? ❑ Yes ❑ N [i0_1 Coliform bacteria is Negative Nitrate mg/L Q Nitrate less than MRL (ND) Arsenic ug/L®❑ Arsenic less than MRL (ND) Collected by Forge Engineering Date of Sample 9/15/21 STATION ❑ Requir aintenance completed Age of lift station years Lift station material Comments: Adequacy test date 9/20/21 Results Q Pass For 5 bedrooms Fluid depth prior to test 18 in Water added 919 gal New depth 22 in Elapsed time 1440 min Final fluid depth 17 in Absorption rate >750 gpd Any rejuvenation treatment (past 12 months) If yes, enter date E. SEPARATION DISTANCES From Private Well on Lot to: (Please enter distances if less than required or if community well) Septic Tank/Lift Station on Lot > 100' p Yes Community Sewer Manhole/Cleanout > 100' r, Yes if No ft M Yes if No ft Neighboring Tank > 100' Yes if No ft Private Sewer/Septic Line > 25' M Yes if No ft Absorption Field on Lot > 100' 0✓ Yes if No ft Holding Tank > 100' 1✓ Yes if No ft Neighboring Absorption Fields > 100' Yes if No Animal Containment > 50' ❑✓ Yes if No ft M Yes if No ft if No ft F. ENGINEER'S COMMENTS Manure/Animal Excreta Storage > 100' Community Sewer Main > 75' E✓ Yes if No ft 0✓ Yes if No ft From Septic/Holding Tank on Lot to: (Please enter distances if less than required) Building Foundations > 10' F71 Yes if No ft Surface Water > 100' ❑✓ Yes if No ft Property Line > 5' p Yes if No ft Wells on Adjacent Lots: Absorption Field > 5' ❑✓ Yes if No ft Private Wells > 100' Yes if No Water Main > 10'_ . El Yes if No ft Community Wells > 200'✓Q Yes if No Water Service Line > 10' E✓ Yes if No ft If septic tank is under driveway comment below From Absorption Field on Lot to: (Please enter distances if less than required) Building Foundation > 10' E✓ Yes if No ft If absorption field is under driveway comment below Property Line > 10' 0 Yes if No ft Wells on Adjacent Lots: Water Main > 10' Yes if No ft Private Wells > 100' Yes if No Water Service Line > 10' Yes if No ft Community Wells > 200' 0✓ Yes if No Surface Water > 100' 0 Yes if No ft F. ENGINEER'S COMMENTS G. ENGINEER'S CERTIFICATION 1 certify that / have determined through field inspections and review of Municipal records that the above systems are in conformance with MOA COSA guidelines in effect on this date. COSA Checklist yellow sheet - 4�!ko *: 49 ,M + Benjarr5chiller CE 12592 • c�`v�s �flF • , 9/22/21 • • '�C� PROFESSI4 VAMW ft ft ft ft tI � I Mi � O =)� ' Z = o ~ O w C,Lij w o0 ,o ,02 C:� N W O 0 m a�1 ca Cn iii✓✓%o < Zvi F 1w70 W r Y o r) ,L'nUA` i! w Z Z U l O N CU ) W J U V) C) z p V? W D = r= - z wz a �o cn w p zzaU Lf) V) � d p N 0x N X�X H p W � W yrj W W V n mow_ N V) NO w CD p � ID T of "t.0 0 cn,pMLI z U 0Li Qf Mi � O =)� ' Z = o ~ O w C,Lij w o0 O v,: W f O OHy V) Ve�) Z, W 0 =W cr-¢Hd j � QC�� wC)LLJ =� �_ �!- W N- nip �¢=~2¢n z W U J¢ p U W `= S CJ Z w= d S w 0 o�Nzo¢Z� SZZv)p na m W z CL w O Mi U� � ¢� n U W N J u J c PZ p �- 6 i -y 2 0 <C W W p N o W U U z � p(D , Cow t=- Li �Zcn C5 zz M, UNC~t_� ¢� ���ui Owf- QwC CD W CJ 6< (}�. 6< Gi W S W Z SCD U 5Q, V) D_LLJ V)4 XOOZOtwi)= - Z L � W �QQ Q \ Q V) w (s,w Q cD VV) V) _Rz l O N N z m z M- LLJ o -cc � Z 6 ~ u _ iii✓✓%o < Zvi F 1w70 W r Y o r) ,L'nUA` i! w Z Z U l O N CU ) W J U V) C) z p V? W D = r= - z wz a �o cn w p zzaU Lf) V) � d p N 0x N X�X H p W � W yrj W W V n mow_ N V) NO w CD p � ID T of "t.0 0 cn,pMLI z U ¢ z Qf t/7 Q z o O ' Z = o ~ O w C,Lij w o0 O v,: W f O OHy V) Ve�) Z, W 0 =W cr-¢Hd W Qj � QC�� O U =� �_ �!- W N- nip �¢=~2¢n z W U J¢ p W W `= S CJ Z w= d S w el= f V) �a-W >y S o�Nzo¢Z� SZZv)p na O ¢z-wW�' -Xym=Xa C) U Q PZ p �- 6 i -y 2 0 <C W W p N o W U U z � p(D , Cow t=- Li �Zcn C5 zz M, UNC~t_� ¢� ���ui Owf- QwC CD W CJ 6< (}�. 6< Gi W S W Z SCD V) V)4 XOOZOtwi)= - Z L �QQ U O Cf) D O N N z m z M- LLJ o -cc � Z 6 ~ u _ CD Z n U J C) a} o Q O V)CD r7 Z cm cm N V) C? o a z x w C'J o Q Vim) �. N � W Z C-7 C CL p iCDz CO 7 3 f z Y o n C V t`- w LC)in o m t� o Municipality of Anchorage Development Services Department °ate ii Building Safety Safe Division On -Site Water and Wastewater Program 4700 Bragaw Street P.O. Box 196650 Anchorage, AK 99519-6650 www.muni.org/onsite RASH* (907) 343-7904 ' CERTIFICATE OF ON-SITE SYSTEMS APPROVAL v "•� FOR A SINGLE FAMILY DWELLING Parcel l.D.05/-t?2- 59 COSA#_� 1. GENERAL INFORMATION ExpirationDate: Complefe legal description SCr.°,l IQ✓9. R/ook Location (site address) Current Property owners) _ T2a y t�1 AV/ f Day phone S 7- 93 9y Mailing address /OiS nll6i!.ST st/a 7 Lending agency Day phone Mailing address Real Estate Agent -� r�_�sr•r„n Day phone 6 ZZ- -?24V Mailing Address—20t,¢yG rt r E.¢r4F ✓2rvER Unless otherwise requested, COSA will be held by DSD for pickup 2. NUMBER OF BEDROOMS: 5 3. TYPE OF WATER SUPPLY: TYPE OF WASTEWATER DISPOSAL: Individual Well Individual Water Storage �] Individual On-site Individual Holding tank ❑ Community Class Well ❑ Community On-site ❑ Public Water System ❑ Public Sewer ❑ The Municipality of Anchorage Development Services Department (DSD) Issues Certificates of On -Site Systems Approval (COSA) based only upon the representations given in paragraph 4 by an independent professional civil engineer registered In the State of Alaska. Certificates of On -Site Systems Approval are required for the transfer of title (except between spouses) for properties served by a single-family on-site wastewater disposal and/or water supper system. DSD also issues COSAs upon request to­bomeowners Certificates-of-On-Site-SystemsApproval are valid for 90 days from the date of issue for properties served by a private or Class C well and may be reissued — -- with new water sample results. (Certificates may be reissued for a period of up to one year with valid water samples.) Certificates are valid for one year for properties served by Class A or B wells or a public water system. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. 4. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based on procedures outlined in the Certificate of On -Site Systems Approval Guidelines for this application, shows that the on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I furiher verify that based on the information obtained from a Municipality of Anchorage files and from my Investigation and inspection, the on-site water supply a from disposal system is(are) in compliance with all applicable Municipal and State codes, o�r�iR regulations In effect at the time of installation. I�� Name of Firm A 0 T N Eng �� q• Phone -45"W— Address Engineer's Printed Name ?5';V6' 5. DSD SIGNATURE _Z" Approved for _5 bedrooms. Date Z" e pp . T / i:ere� Yl. E.1 r Disapproved. Conditional approval for bedrooms, with the following stipulations: WATER AND R Additional Comments --- n—T- Attachments: COSA Checklist Septic System Advisory Well Flow Advisory Nitrate Advisory X Arsenic Advisory Maintenance Agreements Supplemental Engineer's Report Other (R". 11105) Original Certificate Municipality of Anchorage (' Development Services Department Building Safety Division On -Site Water & Wastewater Program 4700 Bragaw Street P.O. Box 196650 Anchorage, AK 99519-6650 www.muni.org/onsite (907)343-7904 CERTIFICATE OF ON-SITE SYSTEMS APPROVAL CHECKLIST Legal Description: 's—'10a I f �� 1 F B/oc i< 3 L 0 7� .00 Parcel ID: �J S/ 132 - SIP A. WELL DATA Well type Date completed l4e/6 7 Total depth 300 ft. Date of test Static water level If A. B, or C provide PWSID # _ Sanitary seal (Y/N) Cased to /0O ft. FROM WELL LOG VY10 7 201 ft. Well production 7 g.p.m, WATER SAMPLE RESULTS: Coliform ,—colonies/100 mL Nitrate mg/L Arsenic: 6.26tmgA Date of sample: 411,P10r B. SEPTIC/HOLDING TANK DATA Tank Type/Material rj ,nen v. a e e/ Tank size $00 gal. Number of Compartments Foundation cleanout (Y/N) 4 Depression over tank (Y/N) /t!' Date of pumping &feoJ Pumper Well Log (Y/N) �, Wires properly protected (Y/N) Casing height (above ground) in. AT INSPECTION Al EuJ ft. Other bacteria Q colonies/100 mL y: dg/ie. Collected br� , En o Date installed !�//3/CZ Cleanouts (Y/N) Z High water alarm (YIN) ' C. ABSORPTION FIELD DATA Date installed t3/9 7 Soil rating (g.p.d-M2 or*6&,) 2 System type 7';F,6 tJC./f Length 67 ft. Width _'S ft. Gravel below pipe " !y ft. Total depth —f— ft. Eff. absorption area 470ftz Monitoring lube * Depression over field Al Date of adequacy test N(5i Results (Pass/Fail) For _ bedrooms Fluid depth in absorption field before test _ in. Water added_ gal. New depth_ In. Elapsed Time: _ min. Final fluid depth _ in. Absorption rate >= g.p,d. Any rejuvenation treatment (past 12 mo.) (YIN & type) If yes, give date D. LIFT STATION IVA4 Date installed Size in gallons Manhole/Access (Y/N) 'Pump on' level at in. 'Pump off" level at _ i . High water alarm Iv at in. Datum Cycles tested Meets alarm 8 uit requirements? E. SEPARATION DISTANCES SEPARATION DISTANCES FROM WELL ON LOT TO: r Septic tank/lift station on lot 10 r f On adjacent lots 1l r Absorption field on lot 16o,-,- On adjacent lots /04 't - Public Public sewer main /1/A Public sewer manhole/cleanout IV14 Sewer /septic service line Al rI' Holding tank "//fl Animal containment areas ,00 r,& Manure/animal excrete storage areas /D d r— SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK ON LOT TO: r Building foundation �r7 �f Propertyline $Q r Absorption field �O Water main //i S` Water service line A0 �t Surface water / �O Wells on adjacent lots 0/ 0 r 'f SEPARATION DISTANCE FROM ABSORPTION FIELD ON LOT TO: Property line Z0 `� Building foundation 2O �� Water main /0 rf, Water Service line /0 rr Surface water X40 rr Driveway, parking/vehicle storage 50 x'06 Curtain drain — Wells on adjacent lots 166 fi F. COMMENTS ti Ar G. ENGINEER'S CERTIFICATION •••. ; `i n`2 I cern that I have determined through field inspections and o'*:• h v �c1-t review of Municipal records that the above systems are in r.,,• 'Y• conformance with MOA COSA guidelines in effect on this date. Engineer's Printed Name sTE�lE EnIG 4�1��� ; sr::oo'w. tis -1 d tf�\•.• PF 62:6 �, �; „� Date Lai-S/l rQ� n,'•.,�. :'.moo �1�1,7 •1.1` •\�`RV .:A^n COSA Fee $ 5 5Q g Waiver Fee $ Date of Payment 14 atD Date of Payment Receipt Number �u 15(� Receipt Number (Rev. 11/05) 30.00 C ra LOT 20 BLOCK 3 HAS \ 43,328 SQ.FT. OF AREA 30.00 NA(i 9WWW 19n A V9014 WPIL 1 CURVE TABLE CURVE I DELTA I RADIUS I LENGTH ^0 Cl 1 1 70.00 ,3 .8 A m� 2 2 1n FOR: Troy Davis Homes Date LanAfark Grad " sngaoeerlag a surreytag. lar. 1261 9330 Vanguard Drive, Suite 203 Anchorage, Aleeka 99507 19071 562-6050 Drawn D y CEF/DL\I 30 on -11200 I" = 50 Lot 20 -Block 3 280073 SCIMITAR Field Book SUBDIVISION 227 UNIT NO. 2 1 hereby certify that the properly described hereon has been surveyed by me, or at my direction, and that the Improvements situated thereon are within the properly lines and do not overlap or encroach on the property lying adjacent thereto unless otherwise shown. That no Improvements on the properly lying adjacent thereto encroach on the premises in question and that there are no roadways, transmission lines or other easements on said property except as shown. It is the responsibility of the owner or builder, prior to construction, to verify proposed building grade relative to finish grade and utility connections and to determine the existence of any easements, covenants, or restrictions which do not appear on the recorded subdivision plat. Listed distances prevail over scaling. Reproduction may cause distortion. 14, �P��•oF.gCso '�s��i CHARLES E. FORBES o �•. LS -7526 • 'ici10 .ce .....••••p!b �