HomeMy WebLinkAboutSKYHILLS PH 3 BLK 2 LT 8kyh1*11s #3 Block 2 Lot 8 #011-122-50 Municipality of Anchorage ;;� t•, Development Services Department r� Building Safety Division Onsite Water and Wastewater Program, 4700 Elmore Road P.O. Box 198850 Anchorage, AK 99507 Page of www cLanchorage.ak.us (907) 343-7904 ON-SITE WASTEWATER DISPOSAL SYSTEM AND/OR WELL INSPECTION REPORT Permit Number. SWO70072 PID Number. 011.122-SO 4.". Jahn and Maury Shea Wastewater System: VI New El Upgrade Ada 8000 Lucy Street Anchorage, AK 99502 ABSORPTION FIELD Plan X,na.asFaioamF 4 pOFF, Tl Dsimlo Tiw0DBW DMara Do W LEGAL DESCRIPTION a T�ap0 �0 12 3 .8 GPoxe F, sack,1 lac a Swow"ort Skyhilis No. 3 DFan b PVF Oaeam earn W" wix* Gni OWM amFFm VPF 8-9 FL 4 FL To.rwv RFnpF S.nan Fa FaaMl•Roca apn4 lye Grn4 LVVM 2-3 FI. 80 FI. Well: ❑ New ❑ Upgrade Mw00 wMro.a4w wF 5 FI. >x.MPa.e.a... 10 FL CMwnraan (Pm.F. A B. C) Toil D.M cow w Tats Faupw Fna PMF VF AW WIJ Water System FI Fr 800 Fe ASTM D3034 PVC Daw Dow DN1W SuaacartsLM Ir WAW DFu 1MWW Fc Red Dog Excavating Ml-2312007 Toa PuapS.M. CF"rgn"plaAaae57 TANK GPM FL Fc SEPARATION DISTANCES 0 Septic ❑ Holding ❑ S.T.E.P. ❑ Other: To Septic Absorption LM Holding uDlr/PrNero uzw•°"•r- Flom Tank Field Station Tank Sewer tine Anchorage Tank 11.250 G4 4nrW Nunn. al Ca"gea�M"4 WO NIA N/A N/A NIA N/A Steel Two (2) sw..wa. >100' >100' N/A NIA LIFT STATION y a,.. La Lft >g >10' NIA N/A G4 'Poop an' Mw 4. 'P,mP Fa' Mfwl 0 Myh w4. W. FL Fa•a•a^ >s >1a NIA N/A k C~ Orel None Noted Pury Maw l Moats Eucmwi I,MpFCOmF D.ranua aT It " BENCH MARK louuon em().. Poon Garage Slab. M"0 100.0 FL A. Harala 8212007 ....... Inspections performed by: Dates: 19 � w •••:S'f�di 2"4 8232007 �lQ;.. Development Services Department Approval *• • 918 e/ •* Conditional Approval Date: ......... �••• 0 E ANDERSON �MIotAa A 0 aiJL• Cc-4381 Reviewed and approved by: U Date: �1��1Q><\�Sa ee`e O N — J33HIS A555 — N O N O I M N O m z ,CL*Clt //-"0.10110 N O 1 0 JM V -1 4 W n 3 4 '1 ,Sl b- --------- ---_ ------ T- 0 1 = a I I N c I co y / .OF all I / I W UJ �' 12 w m = I I H YCO uw -O �S{ I R Fti j< o ujai o. J V) II I Eh 12 —1 I Rm I ov uni• I V J n _ I c W c m� �a 1 1 a Q V) 1 1,J z 7 ¢ W� JO > O •-_- J n I 1 �L O N n W JW WI tit, t,eb+rti�b I h an z I 1 N I I Q I 1 V) I I I 1 L: I I E o ft060 I = e •••. # € L---------------------------1 S 2 d I '1753'3 4.1.01 .� '' o:"'•i ,170'"1 A.M.SODO N //�••• us: :6 Z �• tl Municipality of Anchorage DEVEOPMENT SERVICES DEPARTMENT 4700 Elmore Road Anchorage, AK. 99519-6655 - 343-7904 Onsite Wastewater Disposal System or Well Inspection Report Permit Number. SW070072 87� IDN Um 81 NOTE: Test Hole Deepened During Construction To Verify No Bedrock Within 6'. J 1,250 Gallon J/ Septic Tank 2.6 Drainfield Rock 40' (Trench L 78.0 No Groundwater 7/10/07 99.0UU 98.0 N 2.4 96.0 97.3 95.0 Drainfietd Rock 40' (Trench Length) PROFILE AS -BUILT No Scale Page 3 of 3 PID No. 011-122-50 N U U 87.0 85.8 MUNICIPALITY OF ANCHORAGE DEVELOPMENT SERVICES DEPARTMENT 4700 BRAGAW STREET ANCHORAGE, AK 99519-6650 SOILS LOG - PERCOLATION TEST LEGAL DESCRIPTION: LOT 8, BLOCK 2, SKYHILLS SUBDIVISION No. 3 PERFORMED FOR: JOHN AND MAURA SHEA DATE: 7/2/2007 PROJECT No.: PARCELID#: TECHNICIAN: D. ZAHN DEPTH TEST HOLE 1 Ire) 1 2 3 4 5 6 7 9 10 11 12 13 14 15 16 17 18 19 08/OG •.•.`�:•• SANDY SILT FILL ML •r• SILTY GRAVEL WITH SAND e GM SLOPE 2% SITE PAN SEE SITE PLAN y WAS GROUND WATER ENCOUNTERED, No IF YES ®WFIAT DEPTH" DEPTH OF WATER AFTER MOMTORING: NONE 2% DATE OF MONRORING: 7NOi07 TEST HOLE DEEPENED TO 20' DURING CONSTRUCTION. DATE READING GROSS TIME (MINUTES) NET TIME (MINUTES) D(INCHES) EPTH To WATER N�T DROP (INCHES TEST HOLE PRESOAKED PRIOR TO TESTING: 7/02 1 11:25 3.38" 2 11:55 30 5.50" 2.12" 3 11:56 3.75" 4 12:26 30 5.75" 2.00" 5 12:27 3.25" 6 12:57 30 5.25" 2.00" PERCOLATION RATEL15 (MIN/INCII) PERC. HOLE DIA 8. �� (INCHES) TEST RUN BETWEEN. FT. and 7_5 FT. COMMENTS: TEST HOLE PRE SOAKED PRIOR TO TEST. TEST PERFORMED BY ANDERSON ENGINEERING. I, MICHAEL E. ANDERSON CERTIFY THAT THIS WAS PERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPLE GUIDELINES IN EFFECT ON THIS DATE: 7/10/2007 N 0 g�� D o ,N,'D o to ZT CD rrl Inm a) CD I tot z C p 10 V Qp L=4cz) C) k rn m ; 0o e rri Z�ipn �, � zror, mz gPx� rn 0 cn y pzosz06 or�*` ;D m 1 � 1�G1 �• ,o. o. • SG•••••• .( •� �oYor i O: N 00.05'10"W 144.09' 10' T. & E. ESMT. I I I I I I � I I I I I I I• I I I I 15' T. & E. & GAS ESMT. W 1�1 co 6 �i 9.71 U 240' G co CPS V 10411W 113.73' W O _ LUCY STREET _ R U r-- I I I I I I I I I I I I I I I I I I , I I I to I I� r � 00 IM cn g cl I r N �I z �I , � I I 41.9' I I I I I I I � I I I I I I I• I I I I 15' T. & E. & GAS ESMT. W 1�1 co 6 �i 9.71 U 240' G co CPS V 10411W 113.73' W O _ LUCY STREET _ R U W O r � 00 C.ArnCCD cn g r N V I m W MUNICIPALITY OF ANCHORAGE Development Services Department n 50 On -Site Water 8 Wastewater Program 0 4700 South Bragaw Street P.O. Box 196650, Anchorage, AK 99519-6650 n r� I (907) 343-7904 bl I p ON-SITE WASTEWATER DISPOSAL SYSTEM PERMIT Initial Date Issued: May 23, 2007 Expiration Date: May 22, 2008 Permit Number: SW070072 Parcel ID: 011-122-50 Legal Description: SKYHILLS #3 BLOCK 2 LOT 8 Design Engineer: 0014 ANDERSON ENGINEERING Site Address: 8000 LUCY STREET Owner Name: JOHN & MAURA SHEA Lot Size: 41573 SO. FT. Owner Address: 3653 YOUNG STREET Total Bedrooms: 4 Permit Bedrooms: 4 ANCHORAGE. AK 99508 - This permit is for the construction of: 0 Disposal Field ❑✓ Septic Tank ❑ Holding Tank ❑ Privy ❑ Private Well ❑ Water Storage All construction must be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal Code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72 ) and Drinking Water Regulations ( 18AAC80 ). 3, The engineer must notify DSD at least 2 hours prior to each Inspection. Provide notification by calling (907) 343-7904 ( 24 hours ). ( Not required for a Water Supply Permit only). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must be either: A. Open and closed on the same day. B. Covered, sealed, and heated to prevent freezing. A"W 9/6/07 LoCcLf('on oir bile 5YS1c.i ha6 been nro✓ed. See- 114111. Received Bye--'tLa[.l e—�a`Jl(�SC Date: Municipality of Anchorage Development Services Department Building Safety Division On -Site Water and Wastewater Program 4700 Bragaw Street P.O. Box 196650 r Anchorage, Alaska 99519-6650 www.muni.org/onsite y� v (907) 343-7904 ON-SITE SEWER/WELL Parcell.D. 011-122-50 \O Y PERMIT APPLICATION FOR A SINGLE FAMILY DWELLING Property owner(s) John & Maura Shea Day phone Mailing address 3653 Young Street, Unit A Anchorage, AK Zip Code 99508 Site address 8000 Lucy Street Anchorage. AK Zip Code Legal description (Sub'd., Block & Lot) Lot 8, Block 2, Skyhills Subdivision Phase III Legal description (Township, Range & Section) Lot Size 41,573 Sq. Ft. THIS APPLICATION IS FOR (® all that apply): Absorption Field El Septic Tank El Holding Tank ❑ Privy ❑ Private Well ❑ Water Storage ❑ Number of Bedrooms Four (4) THIS APPLICATION IS AN: Initial Upgrade ❑ Renewal ❑ certify that the above information is correct. I further certify that this application is being made for a Single Family Dwelling and is in accordance with applicable Municipal Codes. (Signature of property owner or authorized agent) Permit/Rush Waiver Fees: Date of Payment: :�� 457 % Date of Payment: Receipt Number. a fi% JAW Receipt Number. (Rev. 11105) ANDERSON ENGINEERING P.O. BOX 240773 ANCHORAGE, AK 99524 522-7773 677-7766 FAX MEMORANDUM DATE: July 10, 2007 TO: Deb Wockenfuss FROM: Mike Anderson, P.E. SUBJECT: Lot 8, Block 2, Skyhills No. 3 Permit No. SW070072 Revised Septic System Location The surface of Lot 8 has been regraded and the owner has requested the septic system location be moved to the front of the lot. Two additional test holes were placed in the proposed location and are shown on the new Site Plan. Soil conditions in the front are identical to those in the back. The percolation rates are the same and the location of the distribution piping in the trenches and the total depth are the same as previously designed. The new absorption system, however will have 2 — 38' long trenches with a flow splitter valve instead of a single 75' long trench. The area in the front of the house is limited by the location of the driveway and the 10' separation distance required from the water service line. The surface of the lot has been totally revised and the ground slope is now toward the east at a 0% to 2% grade. The new trenches will be placed parallel to the ground contours. The attached documentation shows the new location and design of the new septic system. Please review this data and revise the permit accordingly. ANDERSON ENGINEERING P.O. BOX 240773 ANCHORAGE, AK 99524 522-7773 677-7766 FAX May 17, 2007 Municipality of Anchorage Development Services Department On -Site Water and Wastewater Program 4700 South Bragaw Street Anchorage, AK 99519-6650 Subject: Lot 8, Block 2, Skyhills Subdivision Phase III Septic System Design and Permit Application Impacts to Adjacent Properties Dear Onsite Services Engineer: The owner of Lot 8, Block 2, Skyhills Subdivision Phase III intends to construct a new four-bedroom home on the lot. We are therefore requesting a permit be issued for the construction of a new septic system to accommodate the home. The lot is served by the AWWU water system. The attached Site Plan and backup documentation identify the location and configuration of the proposed septic system along with the alternate site. Existing wells and septic systems in the area are also shown on the attached plans. Drainage arrows are shown on the site plan along with ground contours showing the grade and direction of flow on the lot. The drainage pattern will not be changed as a result of this project. The test holes placed on the lot in the area of the absorption trench and alternate site indicated sand and silt (SM) material. The percolation rate of the soil was determined to be 15 minutes per inch. No groundwater was found during the placement of the test holes and none was noted during the monitoring period. An application rate of .8 gallons per day per square foot was used in the design of the absorption system. We are proposing to place a new 1,250 -gallon septic tank and a 75' long by 5' wide by 4' effective depth absorption trench to treat and dispose of the effluent generated in the house. The elevation of the distribution line in the absorption trench will be 7.0' below the surface and the total depth will be 11.0'. A minimum of 3' of fill or 2" of insulation and 2' of fill will be placed over the absorption trench and 4' over the septic tank. The ground surface on the lot in the area of the absorption trench slopes to the west at 5%. The new trench will be constructed parallel with the slope as much as possible in conformance with Municipal requirements. The new septic system will be constructed a minimum of 100' from all wells and any surface water and 10' from the proposed and Lot 8, Block 2, Skyhills No. 3 May 17, 2007 Page Two existing water services in the area. If the system is constructed in accordance with our design the following statements apply: The system, if constructed as designed, will have no adverse impact on the wells in the area or those to be constructed in the future. 2. The system, if constructed as designed, will have no adverse impact on existing septic systems in the area or those to be constructed in the future. 3. The system, if constructed as designed, will have no adverse impact on reserve space, either surface or subsurface, on any lots located in the area. 4. The system, if constructed as designed, will have no adverse impact on drainage patterns in the area. The current drainage pattern will be maintained. Sincerely, /J�l Michael E. Anderson, P.E. Attachments E7 VC Al- E. A10E?SCV NO CL -479+ / LOT 1 i HIDDEN HILLS ♦ W. BOTH AVENUE LOT 8 to LOT 7 W Y Yr LOT 9 :•fie. 49th• ,..._, AREA MAP ;��.: 0�Al:MICHAEL L ANm3t J, ff No. EE-4381 ' � SCALE V = 100' as •.S-1-o7 i .1332l1S kDnl - o n I o•w p .eo3 �o ri w 'U1S3 SYJ W 3 8 '1 ,Sl - -----------_------ ' _ �1�1 Q Lg �. n V , qoi W:: V �V In)Y r A i� R o Q �j _j W I ii Q N w Y i I 8 LLJ O,,: g € 1 s I 1Liv� � m mto n ei I � I tl pn O�1 � � 3 y• i I f Jj 8 05 I z J~O WI I $ =' z I / o� I I I I I I I I i CC • f i s • �C7• rF f °IAi •i�6 i .90'ffi N601.90DO N LOT 8, BLOCK 2, SKYHILLS SUBDIVISION NO.3 DESIGN FACTORS: SYSTEM REQUIREMENTS: Four Bedroom House 5' WideTrench System Perc. Rate: 15 Min./Inch (Est.) 1,250 Gallon Septic Tank Application Rate: .8 GPD/SF 4' Drainfield Rock 4 Bedrooms X 150 GPD/.8 GPD/SF (Application Rate) = 750 SF Absorption Area 750 SF/5 SF/LF'.5 (Red. Factor)= 75 LF Trench Length THEREFORE: Construct 2 Abosrption Trenches Each 38' Long x 5' Wide x 4' Effective Depth. Flow Line Elevation in Trenches to be 7' Below Original Ground Surface. Total Depth to be 11' Below Existing Ground. Provide 4' Cover Over Septic Tank and 3' Cover Over Absorption Trench. Place Flow Splitter Valve to Assure Even Flow to Each Trench. 6'6" Natural Backfill Geotextile Fabric 6" � U 4" Perforated PVC (Holes Down) 47 I I 11>� Drainfield Rock 5' TYPICAL 5' WIDE TRENCH SECTION (NO SCALE) NOTE: Grade Area Over Trench to Drain Away. Minimum 6' Separation From Bedrock. Minimum 4' Separation From Groundwater. Minimum 100' Separation From Welts in the Area. Minimum 100' Separation From Edge of Lake. ? 49th MM LE MlDER No. teals+ MUNICIPALITY OF ANCHORAGE DEVELOPMENT SERVICES DEPARTMENT 4700 BRAGAW STREET ANCHORAGE, AK 99519-6650 SOILS LOG - PERCOLATION TEST LEGAL DESCRIPTION: LOT 8, BLOCK 2, SKYHILLS SUBDIVISION NO. 3 PERFORMED FOR: JOHN AND MAURA SHFA DATE: 7/2/2007 PROJECT No.: PARCEL ID#: TECHNICIAN: D. ZAHN DEPT11 TEST HOLE 1� <rm) 1 2 3 4 5 6 7 9 10 II 1 1 1 1 1 10I:IIRL -,.`+;•• SANDY SILT FILL ML O . SILTY GRAVEL WITH SAND a GM A SLOPE 2% •.I WAS GROUND WATER ENCOUNTERED? No IF YES @ WHAT Dirr DEM I OF WATER AFTER MONRORING: NONE DATE OF MONRORENG: )il0i0l BOH @ 17' SITE PLAN SEE SITE PLAN q DATE READING GROSS TIME NET TIME (MINUTES) Dy ATER D INFT (INCHES) DROP(MINUTES) NCHES) TEST HOLE PRESOAKED PRIOR TO TESTING: 7/02 1 11:25 3.38" 2 11:55 30 5.50" 2.12" 3 11:56 3.75" 4 12:26 30 5.75" 2.00" 5 12:27 3.25" 6 12:57 30 5.25" 2.00" PERCOLATION RATE• 15 (MIN/INCFI) PERC. HOLE DIA 8. �� (INCIIES) TEST RUN BETWEEN. 6_5 FI', and 7_5 FT. COMMENTS: TEST HOLE PRE SOAKED PRIOR TO TEST. TEST PERFORMED BY ANDERSON ENGINEERING. 1, MICHAEL E. ANDERSON CERTIFY THAT THIS WAS PERFORMED IN ACCORDANCE WITH ALLSTATE AND MUNICIPLE GUIDELINES IN EFFECT ON THIS DATE: 7/10/2007 MUNICIPALITY OF ANCHORAGE DEVELOPMENT SERVICES DEPARTMENT 4700 BRAGAW STREET ANCHORAGE, AK 99519-6650 SOILS LOG - PERCOLATION TEST LEGAL DESCRIPTION: LOT 8, BLOCK 2, SKYHILLS SUBDIVISION No. 3 PERFORMED FOR: JOHN AND MAURA SHEA DATE: 7/2/2007 PROJECFNo.: PARCEL ID#: TECHNICIAN: D. ZAHN Drrm TEST HOLE 2 (r«p 1 2 3 4 6 7 8 9 10 11 3I:IIoL ;,.ti; • SANDY SILT FILL ML Ir.L e . SILTY GRAVEL WITH SAND a GM SLOPE 2% J WAS GROUND WATER ENCOUNTERED? NO IF YES 0 WI IAT DFPT1 r DEPTTI OF WATER AFTER MONITORING: NONE DATE OF MONITORING: 771072007 15- 16- 17— 5 1617 BOH @ 17' 18 19 SITE PLAN SEE SITE PLAN 2% DATE READING GROSS TIME (MINUTES) NET TIME (MINUTES) D p7ERO (INCHES) N€T DROP INCHES) TEST HOLE PRESOAKED PRIOR TO TESTING: 7/02 1 11:49 4.25" 2 12:19 30 6.5" 2.25" 3 12:20 4.00" 4 12:50 30 6.13" 2.13" 5 12:51 4.38" 6 1:21 30 6.44" 2.06" PERCOLATION RATELL4(MIN/INCFI) PERC. HOLE DIA. 8 (INCHES) TEST RUN BETWEEN. 6_5 FT. and 7_5 FT. COMMENTS: TEST HOLE PRE SOAKED PRIOR TO TEST. SOIL MATERIALS SAME AS TEST HOLE I. TEST PERFORMED BY ANDERSON ENGINEERING. 1, MICHAEL E. ANDERSON CERTIFY TI IAT THIS WAS PERFORMED IN ACCORDANCE WITH ALLSTATE AND MUNICIPLE GUIDELINES IN EFFECT ON THIS DATE: 7/10/2007 Municipality of Anchorage Department of Health & Human Services 825 L Street, Anchorage, AK 99502-0650 SOILS LOG - PERCOLATION TEST Performed For. Bob Klein Date Performed: {i t Legal Description: Lot 8. Block 2 Sky Hills Phase III SLOPE SITE PLAN 'I I GM Fill It 11 1 16 1 TESTHOLE NO.8-2-8 Apparent Fill Area Was Groundwater Encountered? No If Yet, What Depth? ... Depth to Water After Monitoring None Silty Sand Date: 10/11/99 SM 7-07.14�t �✓ Readin �� ... Perc. Rate: 15 MinAnch Perc. Hole Diameter. 6- 21 Bottom of Test Run Between 8 Ft. and 9 Ft. Hole Comments: Percolation Cavity Presoaked Prior to Testing. Performed By: Ed Sanderson. I, Michael E. Anderson Certify That This Test Was Performed In Accordance With All State and Municipal Guidelines In Effect On This Date: 10/20/99 I r Municipality of Anchorage Department of Health & Human Services 825 L Street, Anchorage, AK 99502-0650 SOILS LOG - PERCOLATION TEST Performed For. Bob Klein Date Performed: Legal Description: Lot A. Block 2. Sky Hills, Phase III SLOPE E 13 14 GM Fill STHO NO 8- -A Apparent FII Area Was Groundwater N C) dP a• Encountered? No If Yet What Depth? , r .. Depth to Water After Monitoring None Silty Sand Date: 10/11/99 SM 49TH CV [AEL !. iN0E25C01 CE•4301 .; S L 20# 58 O �Dit P E • ffilM , r .. Perc. Rate: 15 MinAnch Perc. Hole Diameter. 6" 21 Bottom of Test Run Between 8 Ft. and 9 Ft. Hole Comments: Percolation Cavity Presoaked Prior to Testing. Performed By: Fd Sanderson. I, Michael F. Anderson Certify That This Test Was Performed In Accordance With All State and Municipal Guidelines In Effect On This Date: 10/20/99 ANDERSON ENGINEERING P.O. BOX 240773 ANCHORAGE, AK 99524 522-7773 677-7766 FAX MEMORANDUM DATE: May 22, 2007 TO: Deb Wockenfuss FROM: Mike Anderson, P.E. SUBJECT: Lot 8, Block 2, Skyhills Subdivision Phase III Septic System Permit We have revised the letter for the septic system permit for Lot 8, Block 2, Skyhills Subdivision Phase III to include an application rate of .8 gallons per day per square foot. The application rate is now consistent throughout the permit application package. The distribution line in the absorption trench is designed for placement 7' below the surface or at elevation 103'. The lowest point on the ground surface of the slopes surround the trench is 100' or only 3' lower than the line. This point is more than 80' from the trench. The 25% slope extended from 2.5' above the distribution line would not daylight. The attached slope analysis shows the trench in relation to the surrounding area. Please review this data and advise if further information is required. WAIVER FEE: PAYMENT DATE: RECEIPT #: _MM z•.. s •••• ? N O0OS'10'W 1".08' r Z Si'♦♦ 10' T. • E ESYT. • ! . 9�♦ x _ Sill o I i CA,. �j c '�. z • e�� t� 9 t+ • 1 g I s • I8 7 S I e� R rl in Y _ r pl p g , pt yCl I C to a i HJ j $ L a 8 t t s 1 s M i i s Ys I 2 IQ• I Yr'- ND (-- a o aj S ,@ ' (.rJ D ' I � I t ae '„ /o 1 4 °°t I c I p1 12 15'T. • EX M u . 4 n o9'w�v 11J.T3' EDGE OF ROAD y &� v �I W O LUCY STREET Ci C O N J -P OOi_ J C O N O w—i CT O ZI J �A X N O N_ N O C Cn = a r — 0 r- o -0 r Cn m0 --A (A LA �00� Lo ' 0 a Cm/) co cn r 0 N mc)o o� z7\z �c Q _i m o '0 Z' N Cl) m a) 0 x C) N N O Lq 1 CL co O ON-SITE WASTEWATER DISPOSAL SYSTEM CONSTRUCTION AND MATERIAL SPECIFICATIONS SUBJECT: LOT 8, BLOCK 2, SKYHILLS SUBDIVISION NO.3 GENERAL: The scope of this project includes the procurement and placement of a new 1,250 -gallon septic tank at the location shown on the Site Plan. Work also includes the construction of a new 75' long X 5' wide X 4' effective depth absorption trench at the location also shown on the Site Plan. The distribution line in the trench will be placed at 7.0' below the existing ground surface. Total depth of the trench will be 11.0' below the existing ground surface. The new absorption trench and septic tank must be placed a minimum of 100' from all private wells and any surface water in the area and 10' from the water service line proposed for the lot. A minimum of 3' of cover is required over the absorption trench and 4' of cover over the septic tank. A cleanout must be placed every 50' minimum between the septic tank and the absorption trench. 2. Construction shall be in accordance with the approved site plan, design drawings, Municipal Permit with any special provisions or conditions, and all applicable State and Municipal Wastewater Disposal Regulations. 3. The Contractor shall be responsible for obtaining all underground utility locates and for the layout of the septic system and verification of the location of all lot lines. The Contractor must also verify the location of wells in the area and assure that the separation distances are met. 4. Unless specifically agreed otherwise, the contractor shall be responsible for final grading areas subsequently depressed from soil settling. Property owner shall be responsible for revegetation of affected areas unless specifically agreed otherwise. 5. Contractors installing wastewater disposal systems must be certified by the Municipal Department of Health and Human Services for system installations. Owners installing their own systems must receive prior approval from D.H.H.S. before beginning system installation. SEPTIC TANK INSTALLATION A new 1,250 -gallon septic tank must be procured from an approved source and installed at the location shown. 2. A septic tank is to be constructed by a certified septic tank manufacturer. Construction shall include two 4" cleanouts for pumping access. Lot 8, Block 2, Skyhills No. 3 May 17, 2007 Page 2 of 3 3. The septic tank shall be sufficiently bedded to prevent settling or shifting of the tank. 4. All standpipes on the septic tank shall extend a minimum of 12 inches above final grade. 5. Tanks installed without 4' of cover shall have a minimum of 2" of direct burial insulation. 6. A foundation cleanout shall be installed one to four feet from the building foundation. Two cleanouts are required between the tank and the drainfield. 7. Final grading over the tank shall be such that a positive slope exists away from the septic tank. DRAINFIELD CONSTRUCTION: 1. The drainfield shall be constructed to the dimensions shown on the design. The bottom of the trench shall be within 2" of level. 2. Distribution piping must be placed level with perforations down atop a level bed of drainfield rock. Rock should then be placed over the pipe to provide a minimum of 2" of cover. 3. A silt barrier or geotextile fabric must be placed between the drainfield rock and the natural soil backfill. 4. Monitor tubes must be 4" in diameter and installed at the locations shown on the design. The portion below ground must be perforated. 5. Contractor shall verify the septic tank and drainfield are a minimum 100' away from any private water wells in the area, 150' from a Class "C" Well or 200' from any community well. 6. Direct bury insulation must be placed over the distribution system if less than 3' of backfill depth is available. Finish grade over the trench must be mounded to prevent settlement or depressions. 7. Grade area surrounding the absorption trench to drain away. 8. A minimum 2' of accepting soil is required below the drainfield rock for a 5' wide trench. Contractor shall verify this condition prior to placement of the rock. All pockets of unacceptable materials must be removed and replaced. Lot 8, Block 2, Skyhills No. 3 May 17, 2007 Page 3 of 3 MATERIAL SPECIFICATIONS: Septic tanks must be constructed by a municipally approved septic tank manufacturer. 2. The following pipe materials are approved for use in septic system installations in the Municipality of Anchorage: Cast Iron (perforated and solid), ASTM D3034 or P.V.C. (perforated and solid), ASTM F810 or H.D.P.E. (perforated, but not solid) and ASTM D2662 or A.B.S. (perforated and solid). 3. Insulation shall be at least 2" thick extruded direct burial polystyrene (Dow Chemical Co. Styrofoam HI or equal). 4. Septic tank inlets and outlets shall be fitted with watertight couplings (Caulder, Femco, or equal). 5. A permeable geotextile fabric (Typar, Mirafi or equal) must be installed between the final drain rock layer and the native soil layer. 6. All drain rock shall be .5" to 2.5" in diameter with less than 3% passing the #200 sieve. INSPECTIONS: Municipal Ordinance requires a minimum of two inspections. These inspections must be conducted under the supervision of a professional engineer registered in the State of Alaska. The first inspection must be conducted after the excavation of trenches, beds or pits and before the installation of any gravel. A septic tank may be set in place, but may not be backfilled. The second inspection must be conducted after the placement of the geotextile fabric, gravel, distribution piping, standpipes, cleanouts and insulation. No backfill should be in place at the time of inspection. Contractor shall provide a copy of all field survey layout and construction notes for use in preparing the certified as -built of the completed system. Municipality of Anchorage Development Services Department Building Safety Division / On -Site Water and Wastewater Program 4700 South Bragaw St. P.O. Box 196650 Anchorage, AK 99519-6650 www.ci.anchorage.ak.us (907)343-7904 ON-SITE SEWERIWELL SUBMITTAL COMMENT SHEET To: Anderson Engineering Legal description: SSk hills Phase III, B2 L8 ®Permit ❑C.O.S.A. ❑Inspection Report The attached paperwork has been reviewed and Is being returned for the following reasons: 1. The location of the subsurface disposal field must be fifty feet uphill from any manmade or any natural break In the natural slope of the terrain where the slope changes to 25 percent or greater, unless the top of the drainfield is lower in elevation than the toe of the slope. Please show in a profile cross section that your design meets this requirement or apply for a slope waiver. 2. Your letter says that an application rate of .6 GPD will be used, but the calculations do not reflect .6 GPD. Name of reviewer: Deb Date: 5121107 Please supply the necessary information and re -submit your request. LEAVE THIS FORM ATTACHED TO THE PAPERWORK ANDERSON ENGINEERING P.O. BOX 240773 ANCHORAGE, AK 99524 522-7773 677-7766 FAX May 17, 2007 Municipality of Anchorage Development Services Department On -Site Water and Wastewater Program 4700 South Bragaw Street �� Anchorage, AK 9951 9 6650 S MED Subject: Lot 8, Block 2, Skyhills Subdivision Phase III Septic System Design and Permit Application Impacts to Adjacent Properties Dear Onsite Services Engineer: The owner of Lot 8, Block 2, Skyhills Subdivision Phase III intends to construct a new four-bedroom home on the lot. We are therefore requesting a permit be issued for the construction of a new septic system to accommodate the home. The lot is served by the AWWU water system. The attached Site Plan and backup documentation identify the location and configuration of the proposed septic system along with the alternate site. Existing wells and septic systems in the area are also shown on the attached plans. Drainage arrows are shown on the site plan along with ground contours showing the grade and direction of flow on the lot. The drainage pattern will not be changed as a result of this project. The test holes placed on the lot in the area of the absorption trench and alternate site indicated sand and silt (SM) material. The percolation rate of the soil was determined to be 15 minutes per inch. No groundwater was found during the placement of the test holes and none was noted during the monitoring period. An application rate of .6 gallons per day per square foot was used in the design of the absorption system. We are proposing to place a new 1,250 -gallon septic tank and a 75' long by 5' wide by 4' effective depth absorption trench to treat and dispose of the effluent generated in the house. The elevation of the distribution line in the absorption trench will be 7.0' below the surface and the total depth will be 11.0'. A minimum of 3' of fill or 2" of insulation and 2' of fill will be placed over the absorption trench and 4' over the septic tank. The ground surface on the lot in the area of the absorption trench slopes to the west at 5%. The new trench will be constructed parallel with the slope as much as possible in conformance with Municipal requirements. The new septic system will be constructed a minimum of 100' from all wells and any surface water and 10' from the proposed and Lot 8, Block 2, Skyhills No. 3 May 17, 2007 S LY "' Page Two -y-s c s:' existing water services in the area. If the system is constructed in accordance with our design the following statements apply: 1. The system, if constructed as designed, will have no adverse impact on the wells in the area or those to be constructed in the future. 2. The system, if constructed as designed, will have no adverse impact on existing septic systems in the area or those to be constructed in the future. 3. The system, if constructed as designed, will have no adverse impact on reserve space, either surface or subsurface, on any lots located in the area. 4. The system, if constructed as designed, will have no adverse impact on drainage patterns in the area. The current drainage pattern will be maintained. Sincerely, Michael E. Anderson, P.E. Attachments Municipality of Anchorage Development Services Department Building Safety Division On -Site Water and Wastewater Program 4700 South Bragaw St. P.O. Box 196650 Anchorage, AK 99519-6650 www.ci.anchorage.ak.us (907)343-7904 ON-SITE SEWER/WELL SUBMITTAL COMMENT SHEET To: Anderson Engineering Legal description: Skvhills #3, B2 LS ®Permit ❑C.O.S.A. ❑Inspection Report The attached paperwork has been reviewed and is being returned for the following reasons: Plans were not signed by the engineer. - AtiVi e- Dn a 6o;115- lot o,15- Z. The site plan shall have a description of the topography, areas of excessive slope, and extent of slopes and surface drainage patterns within 100 feet of any part of the system or portion of the lot intended for use for on-site wastewater disposal. AMC 15.65.030 D. Please provide this Information on the site plan. Also, please address If there is a cutback or ditch at the roadway. p`>:'3. On the plot plan submitted for the building permit, the house is located over part of the proposed septic system. If the plot plan Is incorrect, a change order must be submitted to Building Safety. Name of reviewer. Deb Date: 7/13107 Please supply the necessary information and re -submit your request. LEAVE THIS FORM ATTACHED TO THE PAPERWORK ANDERSON ENGINEERING P.O. BOX 240773 ANCHORAGE, AK 99524 522-7773 677-7766 FAX MEMORANDUM DATE: July 31, 2007 TO: Deb Wockenfuss FROM: Mike Anderson, P.E. SUBJECT: Lot 8, Block 2, Skyhills No. 3 Permit No. SW070072 Revised Septic System Location The attached drawing was developed based on the surveyor as built of the foundation currently in place on the lot. The test holes were placed from swing ties to the foundation. A copy of the as built is provided for your use. The surface of the lot has been totally regraded and the ground slope is now toward the east at a 0% to 2% grade. The new trenches will be placed parallel to the ground contours. None of the topography on the lot or within 100' of the new septic system exceeds 10% in slope. A dry ditch is located off the edge of the strip paved road and flows to the north. The ditch is approximately 2' deep with a backslope and foreslope at approximate 2:1 slopes. The ditch has no impact on the placement of the absorption trenches. - 13381s Aim - �$ y Oros d0 3703 �g ,CCCII U110,60.00 N Eli IV ip V •0p , O1 e Eli M W 2 N U o Jw Ymmn rn'�^ 0 V' cY t � J O � Y- a J J Y cn I •g 33P *1 .01 NLOI.90.00 N I I I I I 6 P 0 W J a U rn LOT 8, BLOCK 2, SKYHILLS SUBDIVISION NO. 3 DESIGN FACTORS: SYSTEM REQUIREMENTS: Four Bedroom House 5' WideTrench System Pero. Rate: 15 Min./Inch (Est.) 1,250 Gallon Septic Tank Application Rate: .8 GPD/SF 4' Drainfield Rock 4 Bedrooms X 150 GPD/.8 GPD/SF (Application Rate) = 750 SF Absorption Area 750 SF/5 SF/LF-.5 (Red. Factor)= 75 LF Trench Length THEREFORE: Construct an Abosrption Trench 75' Long x 5' Wide x 4' Effective Depth. Flow Line Elevation in Trench to be 7' Below Original Ground Surface. Total Depth to be 11' Below Existing Ground. Provide 4' Cover Over Septic Tank and 3' Cover Over Absorption Trench. Enter Trench at Midpoint with Effluent Flow. L."- 21 4'0" Natural Backfill _ 5' TYPICAL 5' WIDE TR ti. Geotextile Fabric Perforated 'C (Holes Down) Drainfield Rock CH SECTION (NO SCALE) NOTE: Grade Area Over Trench to Drain Away. Minimum 6' Separation From Bedrock. Minimum 4' Separation From Groundwater. Minimum 100' Separation From Wells in the Area. Minimum 100' Separation From Edge of Lake. °;' 4M MICINEL E "DEW. No. a+ i Municipality of Anchorage Development Services Department e Building Safety Division On -Site Water and Wastewater Program 4700 South Bragaw St. P.O. Box 196650 Anchorage. AK 99519-6650 www.ci.anchorage.ak.us (907)343-7904 ON-SITE SEWER/WELL SUBMITTAL COMMENT SHEET To: Anderson Engineering Legal description: Skvhills #3. B2 L8 ®Permit EIC.O.S.A. ❑Inspection Report The attached paperwork has been reviewed and is being returned for the following reasons: 1. Plans were not signed by the engineer. 2. Please locate the well for the lot to the east. Name of reviewer: Deb Date: 8/2/07 Please supply the necessary information and re -submit your request. LEAVE THIS FORM ATTACHED TO THE PAPERWORK SUl'EE®E� i LOT 1 HIDDEN HILLS �.L 4 W. BOTH AVENUE us C W LOT 7 : �— LOT 8 City Water t � & Sewer J LOT 9 �{`3 49th ..... ..........:.../. v.......s. AREA MAP MICHAEL E. ANDERSON': /y i 1� No. CE -4381 p.SCALE 1' = 100' �j� .A:••$.'',�7 HOZ.••'' �.i I���O�1,pR4 ESS:��•• ••.��w�£p°�1 •.. � F.,¢ y� N oD'05'10'W 144.08' .• ' '+S%••1 10' T. a E ESYT. 0%�°i 41 I to I 1 S i i m• _ m in I I : pt pt $ wi g gb S I i 00 H L_ ri _ s I �, �• I Y �p �� Y I N D n V I /i k L z J l —1— S I Ln p r 1 S I � 1 SI S $ Crl 8 i� 1 .. i 30, ti g b I Z I q wi I � j mi 1 Z 1]'T.k Ed, ae u > m u 09'041V 113.73' � I _ LUCY STREET C- SD o 2 N` N N S0 4m O z m I �2b w ZZto r— to g m E 0 —•� o g����$ 99 ZmCOrn oz rn:uiM 13 � g m a K :u 00 ;u a C) oz JDOOOO <�< Nthin0 -q Zf*i �Oco= m 0 C o �06�=fc Czo Z002gpo AgSM;gd :m OD m N 0(r05'10' W 144 10' T. k E. ESMT. r — — — — — of � M, I I I m ss.o• I C) I I � I I I is.c• I I I I I I I I I I I I I 15'T. k E. h GAS ESMT. W O Y N .s• ,4r ♦♦�� 40 1 o'D'• o '�••q�# ' CD :� 1♦ -J G� I i p •�+ 0 0 O 9 Q +O_ • 0 •ate • ^ . qo% 2 �: �a Jr mks %41 OD m N 0(r05'10' W 144 10' T. k E. ESMT. r — — — — — of � M, I I I m ss.o• I C) I I � I I I is.c• I I I I I I I I I I I I I 15'T. k E. h GAS ESMT. W O Y N .s• y� C A c i C2 A T� '0 N � z�.e• 41.9' c g 4 pL 9.7• r- W O /Icy Ifo / 113.73' Us 8 = OD o � m � N Z co U C O m W _ LUCY STREET _ C� V00 N V C� A c i ^O�$ T� '0 N y C� x189 70 n) , j;:_:.1 � wee Municipality of Anchorag :� On-Site Water and Wastewater Program jV 2 Q 201E 1u.- JI ii (907) 343-7904 ,ArI c T �6 c, Certificate of On-Site Systems Appro ?<< 01 6 8 L Parcel I.D. 011-122-50 Expiration Date: �'S ^ 17 1. GENERAL INFORMATION Complete legal description Skyhills Phase 3 Block 2 Lot 8 Location (site address) 8000 Lucy Street Current Property owner(s) Maura & John Shea Day phone Mailing address 8000 Lucy Street, Anchorage, AK 99502 Real Estate Agent Day phone 2. TYPE OF DWELLING: Single Family (w/wo ADU) ❑ Duplex ❑ Multiple Dwellings (Single Family and/or Duplex) 3. NUMBER OF BEDROOMS: 4 4. TYPE OF WATER SUPPLY: TYPE OF WASTEWATER DISPOSAL: Individual Well ❑ Individual 0 Individual Water Storage ❑ Holding Tank ❑ Community Class Well ❑ Community ❑ Public Water System 0 Public Sewer ❑ WaiverNariance request for: Distance: Received by: L) ttA1f19'U. Date:724i r COSA to be released to the engineer,unless otherwise requested by the engineer. COSA Fee $ 521.. Waiver Fee $ Date of Payment 1-12516 Date of Payment Receipt Number a/54i6 Receipt Number COSA# O`JC.IUt3(02- Waiver# 5. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based on procedures outlined in the Certificate of On-Site Systems Approval Guidelines for this application, shows that the on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation. Name of Firm Forge Engineering Phone (907) 522-7773 Address PO Box 240773 Anchorage, AK 99524 Engineer's Printed Name Benjamin Schiller, PE Date 7/23/18 *4g TM �� *r 6. DSD SIGNATURE 0 ' � System #1 Approved for bedrooms -B• . i . �� � ,. e )am(n�5ch chiller 92 System #2 Approved for bedrooms !f F4 • c7/23/18 .1.• Disapproved �lkiF�pROFESSIONA-, Conditional approval for bedrooms, with the following stipulations: �v • ON-SITE �.. Z WATER AND :0 WASTEWATER o: PROGRAM 9.0 r-carp\I��< By: ,"`' ( Original Certificate Date: —I The Municipality of Anchorage Development Services Division (DSD) issues Certificates of On-Site Systems Approval (COSA) based only upon the representations given in paragraph 5 by an independent professional civil engineer registered in the State of Alaska. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. 7. ATTACHMENTS: t-11 ,. COSA Checklist X Nitrate Adwisp. y.,, Septic System Advisory Arsenic Advisory• , Well Flow Advisory Other ' •-•17,1" -*\ ••; COSA blue sheet! '• .. c If more than 1 septic system is on the lot: COSA Checklist# of Structure served by this system Certificate of On-Site Systems Approval Checklist Legal Description: Skyhills #3 Block 2 Lot 8 Parcel ID: 011-122-50 A. WELL DATA Well type Public If A, B, or C provide PWSID# Well Log (Y/N) N/A Date completed Sanitary seal (Y/N) Wires properly protected (Y/N) Total depth ft. Cased to ft. Casing height (above ground) in. FROM WELL LOG AT INSPECTION Date of test Static water level ft. ft. Well production g.p.m. g.p.m. WATER SAMPLE RESULTS: Coliform colonies/100 mL Nitrate mg/L Arsenic ug/L Date of sample: Collected by: B. SEPTIC/HOLDING TANK DATA Tank Type/Material Septic/Steel Date installed 8/23/07 Tank size 1250 gal. Number of Compartments 2 Cleanouts (Y/N) Y Foundation cleanout (Y/N) Y Depression over tank (Y/N) N High water alarm (Y/N) N Date of pumping 4/05/18 Pumper Drain Masters Inc. C. ABSORPTION FIELD DATA Date installed 8/21/07 Soil rating (g.p.d./ft2 or ft2/bdrm) 0.8 System type 5 - Wide Length 2 x 40 ft. Width 5.0 ft. Gravel below pipe 4.0 ft. Total depth 10.5 ft. Eff. absorption area 800 ft2 Monitoring tube Y Depression over field N Date of adequacy test 7/20/18 Results (Pass/Fail) Pass For 4 bedrooms Fluid depth in absorption field before test 13.5/z2 in. Water added 1061 gal. New depth 20.5/28 in. 1440 14.5/23.5 600 Elapsed Time: min. Final fluid depth in. Absorption rate >= g.p.d. None Any rejuvenation treatment (past 12 mo.) (Y/N &type) If yes, give date D. LIFT STATION Date installed Size in gallons Manhole/Access (Y/N) "Pump on" level at in. "Pump off' level at in. High water alarm level at in. Datum Cycles tested Meets alarm&circuit requirements? E. SEPARATION DISTANCES WELL ON LOT TO: Septic tank/lift station on lot N/A On adjacent lots N/A Absorption field on lot N/A On adjacent lots N/A Public sewer main N/A Public sewer manhole/cleanout N/A Sewer/septic service line N/A Holding tank N/A Animal containment areas N/A Manure/animal excrete storage areas N/A SEPTIC/HOLDING TANK ON LOT TO: >10'Building foundation Property line >5 Absorption field >5 >10' >10' >100' Water main Water service line Surface water Wells on adjacent lots >100 ABSORPTION FIELD ON LOT TO: Property line Building foundation Water main >10' >100' >10' Water Service line Surface water Driveway, parking/vehicle storage Curtain drain None Noted Wells on adjacent lots >100� F. COMMENTS G. ENGINEER'S CERTIFICATION .`�1��\\\` �gl / certify that 1 have determined through field inspections and 0?::.•'pF ,q .1l`i �,� review of Municipal records that the above systems are in g `4�• .-9 �A conformance with MOA COSA guidelines in effect on this date. *: TH A' • * PE • Engineer's Printed Name Benjamin Schiller, (s, " "' ii= " ' Date 7/23/18 0 • '. � • / Benja chiller :• � Il f' -PE'••. CE 12592 •• `�/ �I> •.• 7/23/18 ..•��j�� 1kk PROFESS1O/%. COSA brown sheet 10-10-12.doc