ON-SITE WASTEWATER INSPECTION REPORT
Permit Number: OSP131248 PID Number: 050-531-36 ❑ New ❑✓ Upgrade
Name:
Robert & Heliodora Krenzelok
ABSORPTION FIELD
0 Deep Trench ❑ Shallow Trench ❑ Bed ❑ Mound
Address
4123 Upper Kogru Dr, Eagle River
El Other
Phone
Number of Bedrooms
Soil Rating
Total depth from original grade
4
1 GPD/SF
9 Ft.
LEGAL DESCRIPTION
Depth to pipe invert from original grade
4 Ft.
Gravel depth beneath pipe
5Ft.
Subdivision Block Lot
NORTH SLOPE - EKLUND 2
Fill added above original grade
0 Ft.
Gravel length
30/30 Ft.
Township Range Section
Gravel width
2.5 Ft
Beds: Number of Lines
1 0
Distance between lines
0Ft
SEPARATION DISTANCES
To
Septic
Absorption
Lift Station
Holding
Sewer
Total absorption area
Number of trenches
Dist. between trenches
From
Tank
Field
Tank
Line
600 Fig
2
10 Ft.
Well
110.6
125.0
N/A
N/A
N/A
TANK 11Septic ❑ S.T.E.P. ElHolding E]Other
Manufacturer
Anchorage Tank
Capacity
125OGal,
Surface water
100+
100+
NA
N/A
Material
Number of compartments
Lot Line
60.0
35.2
NA
N/A
Steel
2
NA
Foundation
55.9
68.1
NA
N/A
LIFT STATION
Manufacturer
Capacity
Curtain Drain
50+
50+
NA
N/A
Gal.
Remarks
Pump on level at
in.
Pump off level at
n.
High water alarm at
in.
Pump make and model
Electrical Inspections performed by
Installer
PIPE MATERIAL Housetotank 3034 Tank to
drainfield 3034
JR's Septic Services
Drainfield 3034 CO/MT 3034
Inspector Pannone Engineering Services
BENCHMARK (Assumed elevation) 11011
Inspection isi
dates: 08/08/14 2^a 08/09/14
Location and description -
31" 0
Garage door threshold
COMMUNITY DEVELOPMENT DEPARTMENT APPROVAL
Engineer's Stamp
Or- Qk.4-k1�
Conditional Approval: Date
r (rG
Steven ,` Pannone
�n-4?, • CE 8149/
Approved �(1. Date �-� '/
1 AW
��.F,�p
nspectlon Re _t-1- W.rc -
/ IA /I
/ r I
y
/ / I
NO WELLS W/1 200' ITO
/ / I
rE
/ / I
NOTES:
DRAWING
DRAWN I JRL I
PLAN
I
1
I
I
I
I
I
AND EAST
].0 ED, eA TD !
I_ I1
112.94 I!
----------J--
T Y X. _ *J
w�
PANNONE ENG SVC, LLC
P.O. BOX 100217 ANCHORAGE, AK 99510
PHONE (907) 272-8218 FAX (907) 272-8211
NORTH SLOPE - EKLUND L2
ROBERT & HELIODORA KRENZELOK
4123 UPPER KOGRU DRIVE
EAGLE RIVER, AK 99577
!
--+------------
05/18/15
* 49 TH .. *'I/ 1,.=50'
... .. .... ... P.I.D. NO
50-531-3
Steven R. anWone�/ PERMIT NO.
I�P%ll 149 ..�� OSP131248
''1 �\ftO ss
Shoot
DOF 3
A
B
FC
16.3
15.9
CO
19.3
20.8
Ti
64.6
58.3
T2
70.0
61.0
DCO
71.9
62.2
DCO
72.8
62.8
FS
74.8
63.5
C01
79.1
68.3
MT1
79.5
- 69.4
CO2
87.5
72.3
MT2
88.3
74.3
CO3
108.9
97.5
MT3
111.8
100.7
C04
103.3
95.6
MT4
104.9
97.70
].0 ED, eA TD !
I_ I1
112.94 I!
----------J--
T Y X. _ *J
w�
PANNONE ENG SVC, LLC
P.O. BOX 100217 ANCHORAGE, AK 99510
PHONE (907) 272-8218 FAX (907) 272-8211
NORTH SLOPE - EKLUND L2
ROBERT & HELIODORA KRENZELOK
4123 UPPER KOGRU DRIVE
EAGLE RIVER, AK 99577
!
--+------------
05/18/15
* 49 TH .. *'I/ 1,.=50'
... .. .... ... P.I.D. NO
50-531-3
Steven R. anWone�/ PERMIT NO.
I�P%ll 149 ..�� OSP131248
''1 �\ftO ss
Shoot
DOF 3
SPECIAL PROVISIONS TO SPECIFICATIONS
1. ALL CONSTRUCTION SHALL BE INSTALLED AS SPECIFIED IN THE MOST CURRENT EDITION OF THE MUNICIPALITY OF
ANCHORAGE STANDARD SPECIFICATIONS (MASS) FOR COMPONENT PARTS AND MATERIALS USED IN CONSTRUCTION OF
ON-SITE WASTEWATER DISPOSAL SYSTEMS.
2. ALL WORK WAS IN ACCORDANCE WITH THE ATTACHED SPECIFICATIONS.
3. SCOPE OF WORK: INSTALLED 1250g SEPTIC TANK AND SOIL ABSORPTION SYSTEM.
4.- GROUNDWATER WAS NOT OBSERVED TO A DEPTH OF 16.5' AS EVIDENCED BY THE SOIL TEST HOLE. AN APPARENT
WATER TABLE WAS NOT OBSERVED IN ANY OF THE EXCAVATIONS LESS THAN 16.5 FEET BELOW EXISTING GRADE.
EL. 90.0
EL. 90.0
DESIGN PARAMETERS LEGEND
FILTER FABRIC
PRIMARY/RESERVE SEPTIC SYSTEM ----- '- - WATER LINE/
Cu COPPER
DIP DUCTILE IRON PIPE
NO. BEDROOM: 4 (600 gpd) WELL RADIUS
TH TEST HOLE
4" 0 DRAIN PIPE
FC FOUNDATION CLEAN OUT
PERC RATE = 5 MPI ---------- NEW SEPTIC
T# TANK CLEAN OUT NO.
SOIL RATING: 1.0 GPD/SF -
pRAN ROCK 6" ABOVE PIPE INV
AREA ROD: 600 SF
M# MONITOR TUBE NO.
SYS. TYPE: WIDE TRENCH 5.0' E.D.
TH-t EL. 99.0
- MIN SIZE: 60LF _
DV DIVERTER VALVE
FS FLOW SPLITTER - -
OR
BFG BELOW FINISH GRADE
(2 EA) 30.0' LONG X 2.5' WIDE, 5.0' E.D., 9.0' TD -
OG ORIGINAL GRADE
TOTAL AREA: 600.0 SF
4.0
-3:D
- -
`---`
TS&V TOPSOIL AND VEGETATE
1x6.5
E EXISTING
EL 95.0
f
NOTES:
,���7 7�7� ��7 /''�
PANNONE ENG SVC, U.0
P.O. BOX 100217 ANCHORAGE, AK 99510
PHONE (907) 272-8218 FAX (907) 272-8211
����
of la4.
�� •""' • .
% �y+r
j*:49 •.*��
Date
05/18/15
RECORD DRAWING
EL. 95.0
MA_X�
ASSUMED
5I
25IpN
P.I.D. NO
NORTH SLOPE - EKLUND L2
```
50-531-3
ROBERT & HELIODORA KRENZELOK
4123 UPPER KOGRU DRIVE
/ Steven R. Pannone %PERMIT
.. CE• 8 r
t+ �i .� -
LAN
E�
cSI to
sn+
�10.0�2.5
EL. 90.0
DESIGN NOTES
EAGLE RIVER, AK 99577
_�
iIIFPEpPRQFESS10Npfi�
-12.5 h-
3 OF 3
50.0-
0.0
16.5
t6.5
BOH
NO GROUNDWATER
(5/23/2007)
z
m
00 0
o wo N
�
2" RIGID INS. 56 O
o
Q�
w 0
w
EL. 100.0
V E
0
Z
V
6' INSULATION
EL. 99.0
UNpER DRIVEWAY
7
1250g
NEW
EL. 95.0 -
EL. 96.4 SEPTIC TANK EL. 96.2
EL. 95.0
EL. 90.0
EL. 90.0
DESIGN PARAMETERS LEGEND
ABBREVIATIONS
PRIMARY/RESERVE SEPTIC SYSTEM ----- '- - WATER LINE/
Cu COPPER
DIP DUCTILE IRON PIPE
NO. BEDROOM: 4 (600 gpd) WELL RADIUS
TH TEST HOLE
TANK SIZE: 12508 (E) -
FC FOUNDATION CLEAN OUT
PERC RATE = 5 MPI ---------- NEW SEPTIC
T# TANK CLEAN OUT NO.
SOIL RATING: 1.0 GPD/SF -
C# CLEAN OUT NO.
AREA ROD: 600 SF
M# MONITOR TUBE NO.
SYS. TYPE: WIDE TRENCH 5.0' E.D.
R.I. RIGID INSULATION
DCO DOUBLE CLEAN OUT
- MIN SIZE: 60LF _
DV DIVERTER VALVE
FS FLOW SPLITTER - -
USED:
BFG BELOW FINISH GRADE
(2 EA) 30.0' LONG X 2.5' WIDE, 5.0' E.D., 9.0' TD -
OG ORIGINAL GRADE
TOTAL AREA: 600.0 SF
FG FINISH GRADE
TS&V TOPSOIL AND VEGETATE
E EXISTING
P PROPOSED
NOTES:
,���7 7�7� ��7 /''�
PANNONE ENG SVC, U.0
P.O. BOX 100217 ANCHORAGE, AK 99510
PHONE (907) 272-8218 FAX (907) 272-8211
����
of la4.
�� •""' • .
% �y+r
j*:49 •.*��
Date
05/18/15
RECORD DRAWING
Scale
NTS
4.
.... .. ..... .......
P.I.D. NO
NORTH SLOPE - EKLUND L2
/
50-531-3
ROBERT & HELIODORA KRENZELOK
4123 UPPER KOGRU DRIVE
/ Steven R. Pannone %PERMIT
.. CE• 8 r
t+ �i .� -
N0.
248
DRAWN JRL
DESIGN NOTES
EAGLE RIVER, AK 99577
_�
iIIFPEpPRQFESS10Npfi�
Sheet
sheet
3 OF 3
On -Site Wastewater Disposal System Permit
MUNICIPALITY OF ANCHORAGE
Development Services Department
On -Site Water & Wastewater Program
4700 Elmore Road, PO Box 196650
Anchorage, AK 99519-6650
Telephone: (907) 343-7904
Permit Number: OSP131248
Tax Code Number: 05053136000
Work Type: Septic
Permit Effective Dates: August 05, 2013 to August 05, 2014
Design Engineer: PANNONE ENGINEERING SERVICE
Subdivision: NORTH SLOPE - EKLUND
Site Legal Address: NORTH SLOPE - EKLUND LT 2 G:0703
Owner/Address: KRENZELOK ROBERT P &
HELIODORA CB 4123 UPPER KOGRU DRIVE EAGLE RIVER AK 995770000
Site Mailing Address: 4123 UPPER KOGRU DR, Eagle River
This permit is for the construction of:
Y Disposal Field Y Septic Tank N Holding Tank N Privy
All construction must be in accordance with:
Lot Size in Sci Ft: 38826
Total Bedrooms: A I/
N Private Well N Water Storage
1. The attached approved design.
2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater
Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80).
3. The wastewater code requires inspections during the installation. The engineer must notify the Development Services
Department at least 2 hours prior to each inspection. Provide notification by calling (907) 343-7904 (24 hours).
4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must either:
A. Open and Close on the same day.
B. Covered, sealed, and heated to prevent freezing.
Received By:
Issued By:
I
3
Municipality of Anchorage
P.O. Box 196650 • 4700 Elmore Road
Anchorage Alaska 99519-6650 • (907) 343-7904 • Fax (907) 343-7997
hftp:l/www.muni.org/Onsite
Development Services Division
On -Site Water and Wastewater Program
Ment S,
,N CL
re.
v
e 2rtment
**** VARIANCEIWAIVER REVIEW ****
Waiver#: OSP131249 COSA#: Permit#:OSP131248
PID#:050-531-36
Legal Description: North Slope - Eklund Lot 2
Engineer: Garness Engineering Group
Applicant: Robert Krenzelock
Your request for a waiver of the required 50 feet horizontal separation from the absorption field
to the excessive slope has been approved. The approved separation distance is 35.0 feet.
This waiver approval applies to the proposed absorption field only. Any future upgrade to the
on-site wastewater disposal system will require all separation distances be met or another
approval from this department.
❑ The affected adjacent property owner(s) have been given a 7 day notice regarding this
waiver.
❑ Notarized letter(s) of nonobjection have been received from the owner(s) of the affected
adjacent property.
® Adjacent properties are not affected by this waiver.
.................................................................. 0............
Waiver is Granted: X Waiver is not Granted:
Date: Approved by:
Name of Revi 6r
..........................................................0 •...................
Ree#: 84321 Amount: $176.00 Date Paid: 8128107
**** VARIANCEIWAIVER REVIEW ****
r"
y
P
**** VARIANCEIWAIVER REVIEW ****
Waiver#: OSP131249 COSA#: Permit#:OSP131248
PID#:050-531-36
Legal Description: North Slope - Eklund Lot 2
Engineer: Garness Engineering Group
Applicant: Robert Krenzelock
Your request for a waiver of the required 50 feet horizontal separation from the absorption field
to the excessive slope has been approved. The approved separation distance is 35.0 feet.
This waiver approval applies to the proposed absorption field only. Any future upgrade to the
on-site wastewater disposal system will require all separation distances be met or another
approval from this department.
❑ The affected adjacent property owner(s) have been given a 7 day notice regarding this
waiver.
❑ Notarized letter(s) of nonobjection have been received from the owner(s) of the affected
adjacent property.
® Adjacent properties are not affected by this waiver.
.................................................................. 0............
Waiver is Granted: X Waiver is not Granted:
Date: Approved by:
Name of Revi 6r
..........................................................0 •...................
Ree#: 84321 Amount: $176.00 Date Paid: 8128107
**** VARIANCEIWAIVER REVIEW ****
MUNICIPALITY OF
Community Development Department
Development Services Division
On -Site Watel, & Wastewater Program
Phone: 907-343-7904
Fax: 907-343-7997
t ON-SITE SEWER/WELL PERMIT APPLICATIONao
,• a J} t;J`
Parcel I.D. 050-531-36
Property owner(s) Robert Krenzelok & CB Heliodora
Day phone
Mailing address 4123 Upper Kogru Drive, Eagle River, AK 99577
Site address 4123 Upper Kogru Drive
Legal description (Sub'd., Block & Lot) North Slope - Eklund, Lot 2
Legal description (Township, Range & Section)
Lot Size 38,826 Sq. Ft.
APPLICATION IS FOR:
(M all that apply)
Number of Bedrooms/13'
APPLICATION IS AN: TYPE OF DWELLING:
Absorption Field ❑X Initial ❑ Single Family (SF) ❑X
Septic Tank ❑X Upgrade ❑ (w/wo ADU)
Holding Tank ❑ Renewal 0Duplex (D) F-1
Multiple Dwellings ❑
Privy ❑ (SF and/or D)
Private Well ❑
Water Storage ❑
THIS APPLICATION INCLUDES A VARIANCE / WAIVER REQUEST FOR:
Distance:
I certify that the above information is correct. I further certify that this is in accordance with
applicable Municipal Codes.
I` ? -- — --
(Signature of property owner or authorized agent)
Permit/Rush Fees: li � D— -I < y aiver Fees:
Date of Payment: i 3 C Date of Payment:
Receipt Number: D`S6`t�1 Receipt Number:
Permit No. 05121_;�12ge Waiver No.
Permit App_:- :- : L..:c
Pannone Engineering Services uc
Steven R. Pannone, Principal
Registered Professional Engineer
E-mail: steve@panengak.com
August 2, 2013
Municipality of Anchorage
Development Services Department
On -Site Water & Wastewater Program
4700 S. Bragaw Street
P. O. Box 196650
Anchorage, Alaska 99519
Subject: North Slope — Eklund, Lot 2
Septic System Permit Renewal Request
SW080164
Ladies and Gentlemen:
)'a<er nor `�•P'
I am writing to request a renewed permit to inst I a septic system be issued for this property. The
proposed systems will serve a }bedroom house. Currently the lot is developed. This
system will be over 100' from the private well on this lot. The surrounding developed lots are also served
by private wells that are over 100 feet from this septic system.
P.E.S. Visited the site in July of 2013 and conditions remain the same as at the time the original permit
was issued. The test hole monitoring tube was found to be dry on 7/1/2013.
The proposed installation will not affect the future development of the surrounding or existing lots. There
are no wells or septic systems within 100 feet of the proposed septic location.
If you have any questions or concerns, please contact me at 272-8218.
Sincerely,
Steven R. Pannone, P.E.
Mailing: P.O. Box 100217, Anchorage, AK 9111510-0217
Physical: 332 East Manor, Anchorage, AK 99501
Telephone: (907) 272-8213 FAX: (907) 272-8211
MUNICIPALITY OF ANCHORAGE
Development Services Department
On -Site Water 8 Wastewater Program
4700 South Bragaw Street
P.O. Box 196650, Anchorage, AK 99519-6650
(907) 343-7904
ON-SITE WASTEWATER DISPOSAL SYSTEM PERMIT
Renewal
Permit Number: SW080164
Legal Description: NORTH SLOPE - EKLUND LOT 2
Design Engineer: 0855 GARNESS ENGINEERING GROUF
Owner Name: BOB KRENZELOK
Owner Address: 4123 UPPER KOGRU DRIVE
EAGLE RIVER. AK 99577 -
Date Issued: Jut 30, 2008
Expiration Date: Jul 30, 2009
Parcel ID: 050-531-36
Site Address: 4123 UPPER KOGRU DRIVE
Lot Size: 38826 SO. FT.
Total Bedrooms: 4 Permit Bedrooms: 4
This permit is for the construction of:
❑✓ Disposal Field g Septic Tank ❑ Holding Tank ❑ Privy ❑ Private Well ❑ Water Storage
All construction must be in accordance with:
1. The attached approved design.
2. All requirements specified in Anchorage Municipal Code Chapters 15.55 and 15.65 and the State of Alaska
Wastewater Disposal Regulations ( 18AAC72 ) and Drinking Water Regulations ( 18AAC80 ).
3. The engineer must notify DSD at least 2 hours prior to each Inspection. Provide notification by calling
(907) 343-7904 ( 24 hours ). ( Not required for a Water Supply Permit only).
4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather
must be either: A. Open and closed on the same day.
B. Covered, sealed, and heated to prevent freezing.
Received By:
Issued
Date:
+ / f
Date:
Municipality o nc iorag
.� - Development �Smjpi e_ p
c s De �rtment Building Safety Division
On -Site Water and Wastewater Program
4700 Bragaw Street
P.O. Box 196650
Anchorage, AK 99519-6650
www.muni.orglonsite
(907)343-7904
ON-SITE SEPTIC/WELL PERMIT APPLICATION
FOR A SINGLE FAMILY DWELLING
Parcel I.D. 5510 — 531-34r-
Property
31-34r
Property owner(s) �C3F3 V, RW Dk Day phone 350 —1Qlc'�
Mailing addressy ��3 UDQ� to `�1� Zip Code 99513
Site address
Legal description (Sub'd, Block & Lot)
Code
Legal description (Township, Section & Range) M0V4'h gh* — E�JL) IA tDT Z —
Lot Size 3'8$o'L(0 Sq. Ft.
THIS APPLICATION IS FOR (®all that apply):
Absorption Field
Q
Septic Tank
❑
Holding Tank
❑
Privy
❑
Private Well
❑
Water Storage
❑
Number of Bedrooms 4
THIS APPLICATION IS AN:
Initial
❑
Upgrade
❑
Renewal
I certify that the above information is correct. I further certify that this application is being made for a
Single Family Dwelling and is in accordance with applicable Municipal Codes.
(Signature of property ownelor authorized agent)
Permit/Rush Fees: f•� Waiver Fees:
Date of Payment:`' Date of Payment:
Receipt Number. Receipt Number:
(Rev. 11/05)
MUNICIPALITY OF ANCHORAGE
Development Services Department
On -Site Water B Wastewater Program
4700 South Bragaw Street
P.O. Box 196650, Anchorage, AK 99519-6650
(907) 343-7904
ON-SITE WASTEWATER DISPOSAL SYSTEM PERMIT
Initial
Date Issued: Jun 12, 2007
Expiration Date: Jun 11, 2008
Permit Number: SW070102 Parcel ID: 050-531-36
Legal Description: NORTH SLOPE - EKLUND LOT 2
Design Engineer: 0855 GARNESS ENGINEERING GROUF Site Address: 4123 UPPER KOGRU DRIVE
Owner Name: BOB KRENZELOK Lot Size: 38826 SO. FT.
Owner Address: 4123 UPPER KOGRU DRIVE Total Bedrooms: 4 Permit Bedrooms: 4
EAGLE RIVER. AK 99577 -
This permit is for the construction of:
Q Disposal Field ❑,/ Septic Tank ❑ Holding Tank ❑ Privy ❑ Private Well ❑ Water Storage
All construction must be in accordance with:
1. The attached approved design.
2. All requirements specified in Anchorage Municipal Code Chapters 15.55 and 15.65 and the State of Alaska
Wastewater Disposal Regulations (18AAC72 ) and Drinking Water Regulations (18AAC80 ).
3, The engineer must notify DSD at least 2 hours prior to each Inspection. Provide notification by calling
(907) 343-7904 ( 24 hours ). ( Not required for a Water Supply Permit only).
4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather
must be either: A. Open and closed on the same day.
B. Covered, sealed, and heated to prevent freezing.
Received By.
Date:
Municipality of Anchorage
(• Development Services Department '
Building Safety Division
On Site Water & Wastewater Program
4700 Bragaw, St.
P.O. Box 196650
Anchorage, AK 99519-6650
www.ci.anchorage.ek.us
(907)343-7904
ON-SITE SEWER/WELL PERMIT APPLICATION
FOR A SINGLE FAMILY DWELLING
Parcel I.D. 6 SD 5.3 / 235 Q
Property owner(s) BOB KRFN7FLOK Day phone 250-8348
Mailing address 4123 : KOGRU DRIVE
Site address
Legal description (Sub'd, Block & Lot ) NORTH SLOPE — FKLUND. OT
Zip Code 99577
Legal description (Township, Section & Range) _N/A
Lot Size 3E, 8 �" Sq.Ft. Number of Bedrooms _ 3
THIS APPLICATION IS FOR (®all that apply):
Absorption Field
❑
Septic Tank
19
Holding Tank
❑
Privy
❑
Private Well
❑
Water Storage
❑
THIS APPLICATION IS AN:
Initial
❑
Upgrade
Renewal
❑
I certify that the above information is correct. I further certify that this application is being made for a
Single Family Dwelling and is in accordance with applicable Municipal codes.
GARNESS ENGINEERING GROUP, Ltd.
Permit/Rush Fees: W_ D . O(D
Date of Payment: C / 1 10-7
Receipt Number: 5 -7b )
(Rev. 11/05)
Waiver
Date of Payment:
Receipt Number:
SW 0-7 (-) I a 2
GARNESS ENGINEERING GROUP, Ltd.
^_*%,- CONSULTANTS B GENERAL CONTRACTORS r=l:
August 23, 2007
Municipality of Anchorage
Development Service Department
On -Site Water& Wastewater Program
4700 Bragaw Street
P.O. Box 196650,
Anchorage, Ak 99519-6650
(907)343-7904
Ref: Revisions to Proposed Septic Upgrade for forth Slope - Eklund; I of 2,
To whom it may concern:
A sewer upgrade permit (SW070102) was issued for a 3 bedroom house for the referenced property.
Since the issuance of the permit, it has come to our attention that the house is actually a 4 bedroom
residence. We request the permit be reissued for a 4 bedroom house. Attached is a revised design
drawing. The original design showed that we were proposing to use a 0.8 application rate. The percolation
rate was 5 minute/inch which is a 1.2 application rate. We have changed the design to use a 1.0
application rate. We are proposing that 1250 gallon septic tank and a dual 5 -wide trench type drainfield be
installed as shown on the design. An alternate site for a 4 bedroom system is shown on the design which
will require the use of a advanced wastewater system.
TOPOGRPAIIY: As can be seen on the attached design drawing the average topography below the
drainficld is a 5-15 percent slope running approximately east to west. There also a 5 to 6 foot cutbank
along the road approximately 35 feet down hill from the proposed alternate site. As can be seen on the
attached cross section drawing, at a 25 percent slope 2.5 feet above the top of the distribution line, the line
docs not daylight. In short there is no slope concern downhill form the proposed alternate site.
We arc unaware of any adverse impacts this installation would have on adjacent wells or septic systems.
If you have any questions, please contact us at 337-6179. Thank you for your assistance.
WAIVER FEE: '07/ice '
PAYMENT DATE: 8810 7
M.S.RECEIPT#: WOP-1
N07t: Attached is a site plan drawing, a design drawing, one soil log, which are all part of the design package for
this septic system. (Contact C.E.G. Ltd. for 7 page construction specification letter.)
3701 E. Tudor Road, Suite 101 • Anchorage, AK 99507-1259
Ph: (907) 337-6179' Fax: (907) 338-3246 • Website: www.gamcsscnginecring.com
\ STREAM LOCATION /
\\ \ (PER MOA GRID MAP)
/,,-'EKWND. LOT 2.
BLOCK 2
\� HAST)
DOSTING 3
BEDROOM
HM)cc,
/ / \
EKLUND. / LOT 3. / I/ s
/ /p
J L` R —
t` PROF
I I �
I EKLUND. LOT 2.
I I BLOCK 1
I rACMm
I I
J L_ -------_--
KIRK. LOT 2.
(NO CONCERN)
I
`�
I
NORTH
_ %nc
EKLUND; LOTS 1 �1�
`Y,
I �APPRO%INMATE THREAD OF STREAM
—
I
I \ r I
/ NORTH SLOPE /2. \
/ BLOCK 5. LOT 150, WELL pApnis
\ AREA I
a i I
� I
I
)HIV. UlM)
GARNESS
ENGINEERING
GROUP, Ltd.
CONSULTANTS& GENERAL CONTRACTORS
�••••:•••
....:...
1Ml [ TlDJR AYD. lIIIR 101 IIRYi09R. Mf M01 HILK (b�IJJ1-�1A 11Y (W1N1a-]]N � 1RBLR mow. .tan.
PREPARED FOR:
BOB KRENZELOK
PHONE NUMBER:
622-1587
PACE NUMBER: ••• . ......••
1 OQ '•, Y G
.••••••••
es
OF 2 p
LEGAL DESCRIPTION:
DRAWN BY: O °o,• GE -79 3
��0��'
NORTH SLOPE —
EKLUND, LOT 2
B.F.M. b�!? pqL
TWE OF WORK:
DATE. REVISED
SITE PLAN FOR SEPTIC SYSTEM UPGRADE
6/12/2007
)HIV. UlM)
NUMBER OF BEDROOMS:4
GALLONS PER DAY (GPD): 600
PERCOLATION RATE/S: 5 MIN./INCH
PROPOSED APPLICATION RATE: 1.0
MINIMUM DRAINFIELD SO.FT.: 600
IM DEPTH: 10 FEET
2.5 FEET
1:2 O 30 FEET
APPROVED SAND FILTER: N/A
NE:5 FEET
DON FACTOR:N/A
. SO.FT.: 600
TO OBTAIN A COPY OF THE LETTER
CONTACT GEG. BY PROCEEDING FORWARD
WITH THIS INSTALLATION, THE ENGINEER,
WELL DRILLER, CONTRACTOR AND
PROPERTY OWNER AGREE THAT THEY
HAVE READ THESE SPECIFICATIONS AND
AGREE TO ACCEPT THE TERMS AND
ALL SURROUNDING WELL RADII. LOT
LINES. AND EASEMENTS, MUST BE
FLAGGED BY A REGISTERED LAND
SURVEYOR. PRIOR TO CONSTRUCTION
L �
ALTERNATE SITE WILL \ PROPOSED
/ REQUIRE ADVANCE \1250 GALLON ~(
/ TREATMENT SYSTEM SEPTIC TANK
UT WT
Li I I I 11
V (SEE PAGE 3 OF 3)I I 11 TN I I I
T I 11\
CO CO
PROPOSED
(� DRAINFIELDS I
APPROXIMATE
BE ATE WELL RADIUS T
TO BE FIACCED BY A
REGISTERED LAND SURVEYOR
PRIOR TO CONSTRUCTION
DOUBLE
CLEANOUTS
SHED
\\`
S E:
II' - 40'
1
OLD SEPTIC TANK AND
DRAINFIELD TO BE
ABANDONED PER UPC
INSULATE WITH 4' THICK
BLUE BOARD, 4' WIDE
IN DRIVEWAY AREA
/
I
_off QO
0
o �F,••• .... Cq��p
GARNESS ENGINEERING GROUP, Ltd.p,
per.' H •'•."9
CONSULTANTS d GENERAL CONTRACTORS �••••...• . ••••• ••••••.•••
IMI C TMM AMO. 91AR I01 M1pgAK.O, M( 99107 . 1Nd1[ (101)31)-{119 • FM (W7) -])N . R991L' w�.9w,wwgNrM1�9vn
PREPARED FOR: PHONE NUMBER: PAGE NUMBER: �••• • •••••• ...... ••••
BOB KRENZELOK 622-1587 2 OF 3 Q '• e y mess:'
LEGAL DESCRIPTION: DRAWN BY: a.11CE 79 3
NORTH SLOPE - EKLUND. LOT 2 K.D.M. �Q e ' Q.FLTJP ��Ao
TYPE OF WORK: DATE' REVISED 44000000 rofesslo�
PROPOSED SEPTIC SYSTEM UPGRADE 8/23/2007
IM1IY. V IMI
/
1
W
I�
a
'2
.•F
'N
o
IN
'S
I
_off QO
0
o �F,••• .... Cq��p
GARNESS ENGINEERING GROUP, Ltd.p,
per.' H •'•."9
CONSULTANTS d GENERAL CONTRACTORS �••••...• . ••••• ••••••.•••
IMI C TMM AMO. 91AR I01 M1pgAK.O, M( 99107 . 1Nd1[ (101)31)-{119 • FM (W7) -])N . R991L' w�.9w,wwgNrM1�9vn
PREPARED FOR: PHONE NUMBER: PAGE NUMBER: �••• • •••••• ...... ••••
BOB KRENZELOK 622-1587 2 OF 3 Q '• e y mess:'
LEGAL DESCRIPTION: DRAWN BY: a.11CE 79 3
NORTH SLOPE - EKLUND. LOT 2 K.D.M. �Q e ' Q.FLTJP ��Ao
TYPE OF WORK: DATE' REVISED 44000000 rofesslo�
PROPOSED SEPTIC SYSTEM UPGRADE 8/23/2007
IM1IY. V IMI
'F 'i5t� iDiVNi i
ROAD 1g PiRC��i
i
PROPOSED ALTERNATE SRE—/
GARNESS ENGINEERING GROUP, Ltd. pA'?
CONSULTANTS d GENERAL CONTRACTORS
im, L TID'Jt IIGD. lIIR 101 . WOCM�GL AI! Mb) . 9�p[ (9011]11-91A 1Y (901}119-]t4 . RBSOL w�.,w�pnw9pan� O
PREPARED FOR: PHONE NUMBER: PACE NUMBER: Q••••
BOB KRENZELOK 622-1587 3 OF 3 Qom'
LEGAL DESCRIPTION: DRAWN BY: OQ�O,•
NORTH SLOPE - EKLUND, LOT 2 J.L.M. p
TYPE OF WORK: DAIL: REVISED
CROSS SECTION OF TOPOGRAPHY 1 8/23/2007
IROV. V 1NJ)
GA' orness•-
CE -79,3 e�
GARNLSS ENGINEERING GROUP, Ltd.
— — - -_ - -- CONSULTANTS E GENERAL CONTRACTORS —
SOIL LOG — PERCOLATION TEST
LEGAL DESCRIPTION: NORTH SLOPE — EKLUND. LOT 2
PERFORMED FOR: 808 KRENZELOK D)
DEPTH
(feet) '== TEST HOLE 1
1 »»
2
�a==
====
ORGANICS SOIL
CLASSIFICATIONS
ORG
GW =---
2:10
—
+ t
GP
ML
3
30
0"
6'
3
2:40
—
6•
GM
CL
a
30
0"
GC Tj M
OL
3:10
—
°e •°e a
SW
MH
5
30
•� •
SP
CH
SC ' :
OH
6
7
(]
9
10 GM TO SM
w/ LARGE
COBBLES a
11 BOULDERS
12
13
14
15
16
17
18
DEPTH TO
GROUNDWATER
DATE
DRY
5/23/2007
DRY
5/30/2007
2:10
—
6•
—
F
................
p J y A. ness:
° CEE-7973 :o'
a e� �'' •i/��.. 6� cgo4
�4440000�
N 1
I
TH/1� I
DATE READING
CLOCK
TIME
NET TIME
(MINUTES)
WATER LEVEL
READING
NET DROP
(INCHES)
5/25/2007 1
2:10
—
6•
—
2
2:40
30
0"
6'
3
2:40
—
6•
—
4
3:10
30
0"
6-
5
3:10
—
6•
—
6
3:40
30
D.
6�
19� PERCOLATION RATE 5 (MIN./INCH) PERC. HOLE DIA. 6 (INCHES)
TEST RUN BETWEEN 4.5 FT. AND 5.0 FT.
20 A FOUR HOUR PRESOAK WAS PERFORMED: N YES ❑ NO
SOILS LOGGED BY: JODY MAUS PERCOLATION TEST PERFORMED BY: BENNY MAUS
COMMENTS:
PERFORMED BY CEG, Ltd. I, JEFFREY A. GARNESS, CERTIFY THAT THIS WASP FORMED IN ACCORDANCE
S1
WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE: /
R
- G D E MINEERING & DEVELPMENT CO.
Boz 90, Davis St, Eagle River, Alaska 99577
694-2774 or 333WW
- RossN Oyster
694-2774
Civil Engineering
Sass Er Foundations
SOIL LOG
Earl Be
3335240
Surveying
Land Development
Performed for: Name: ��
J p��J `�,
x�t;
Tel. No.
Mailing Address:
Legal. Description: V csC
th (feet)
Soil
Characteristics
0
wR�
2
5,�-cy �a,az� Grz'�v�.>✓
3 %CA - �O� Coa O �vs Co X36 Aan amu. �g
4
5 �P- \ 5o 4n. �k�Ca�7�AQ:� Seib - CGiga +� Uu,j¢cc1
s Gam- \776 -Sn'kv.
8
9
10
11
12 'dao G�A�49 @�a W �z'36'Es
�A` _ Gcza,vt*s� - -� q«t.>_-� Cc5Ae5� Mkafi�tx,A>•.,
OM
Ground Water Encount'ered: fes No -7 if yes, what depth
Proposed Installation: Seepage Pit✓ 'Drain Field
Comments: 1b��.J Tr,a� Ac�f� @+. —�a,P \\ \7,\
Performed by: Date:— to.�.�� -7�
Municipality of Anchorage ••
On-Site Water and Wastewater Program
t c-. (907) 343-7904
ci:i I 1
CERTIFICATE OF ON-SITE SYSTEMS APPROVAL
Parcel I.D. 050-531-36 Expiration Date: /(731' /7
1. GENERAL INFORMATION
Complete legal description North Slope-Eklund Lot 2
Location (site address) 4123 Upper Kogru Dr, Eagle River, AK
Current Property owner(s) Krenzelok Day phone 350-1972
Mailing address same
Real Estate Agent Owner Day phone 350-1972
6i897"•
u
2. TYPE OF DWELLING: ti
® Single Family (w/wo ADU) E AUG 2 4 ZO�:
Duplex a.
❑
El Multiple Dwellings (Single Family and/or Duplex) �6 '/
�� 016gi3O
3. NUMBER OF BEDROOMS: 4
4. TYPE OF WATER SUPPLY: TYPE OF WASTEWATER DISPOSAL:
Individual Well ® Individual
Individual Water Storage ❑ Holding Tank El
Community Class C Well ❑ Community ❑
Public Water System ❑ Public Sewer ❑
Received by: ) Date: (--/3/(/ 7
COSA to be released to the engineer,unless oth ise requested by the engineer.
COSA Fee $ 52t, Date:
Date of Payment 8/2(1I/? Date of Payment
Receipt Number 0 /200 Receipt Number
COSA# 6 50'�633 Waiver#
5. STATEMENT OF INSPECTION BY ENGINEER
As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation,
based on procedures outlined in the Certificate of On-Site Systems Approval Guidelines for this application,
shows that the on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate
for the number of bedrooms and type of structure indicated herein. I further verify that based on the information
obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water
supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal and State codes,
ordinances, and regulations in effect at the time of installation.
Name of Firm NorthRim Engineering Phone 694-7028
Address PO Box 770724, Eagle River
Engineer's Printed Name Steve Eng Date 8/22/2017•
6. DSD JGNATURE -0, � •••• •r•••;
System #1 Approved for bedrooms.
51e"cn W. Ent , ��d
System #2 Approved for bedrooms. `` �E b.tI .�`' '
•
•
Disapproved. '} •�° \''.
Conditional approval for bedrooms, with the following stipulations:
•
1-\ 1D
••
By: ��� slrr.✓ 7. Original Certificate Date: 007
The Municipality of Anchorage Devlopment Services Division(DSD)Issues Certificates of On-Site Systems Approval(COSA)based only
upon the representations given in paragraph 5 by an independent professional civil engineer registered in the State of Alaska.The
Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work.
7. ATTACHMENTS:
COSA Checklist X Nitrate Advisory
Septic System Advisory Arsenic Advisory
Well Flow Advisory Other
COSA blue sheet 9-1-12.doc
•
If more than 1 septic system is on the lot:
COSA Checklist# of
Structure served by this system
Cerfficate of On-Ste Systeins ApprovaD CheckDast
Legal Description: /14/1-4 S/C�,4 - �lclJplt/� 4 �� Parcel ID:DSD53/y(
A. WELL DATA `
Well type P If A, B, or C provide PWSID# Well Log (Y/N) //
Date completed VA/k. Sanitary seal (YIN) 4� Wires properly protected (Y/N) y
Total depth 1// //-ft. Cased to V R-ft. Casing height (above ground) r2, in.
FROM WELL LOG AT INSPECTION
Date of test — cPiy/l 7
Static water level ft. 31, -s ft.
Well production g.p.m. 1/f g.p.m.
WATER SAMPLE RESULTS:
Coliform Q colonies/100 mL Nitrate 3 /mg/L /
Arsenic NJ ugIL Date of sample: t III 17 Collected by: A/3- 11- 1(1),...-t,
B. SEPTIC/HOLDING TANK DATA
Tank Type/Material gar c- .S TE L Date installed CP//f///44/
Tank size /150 gal. Number of Compartments Z Cleanouts (Y/N)
Foundation cleanout (YIN) •7( Depression over tank (Y/N) /V High water alarm (Y/N) l //
Date of pumping 6P/Z7/1 7 Pumper
C. ABSORPTION FIELD DATA
Date installed (f/ttbit Soil rating (g.p.d./ft2 or ft2/bdrm) l System type .e.1
Length 3 0 3 ° ft. Width Z• 5 ft. Gravel below pipe ft.
Total depth ! ft. Eff. absorption area 66 ft2 Monitoring tube Depression over field
Date of adequacy test 7 Results (Pass/Fail) P For bedrooms
q y ��/ �
Fluid depth in absorption field before test 0 in. Water added d 00 gal. New depth 2 in.
Elapsed Time: 3 0 min. Final fluid depth in. Absorption rate >= 6620 g.p.d.
Any rejuvenation treatment (past 12 mo.) (Y/N & type) /A1/ If yes, give date
O.
D. LIFT STATION W4
Date installed Size in gallons Manhole/Access (Y/N)
"Pump on" level at in, "Pump off" level at in. High water alarm level at in,
Datum Cycles tested Meets alarm&circuit requirements?
E. SEPARATION DISTANCES
WELL ON LOT TO:
Septic tank/lift station on lot /7d " • On adjacent lots /Q't1 �',-
f �
Absorption field on lot /Da On adjacent lots /d f 7
Public sewer main / Q a (r Public sewer manhole/cleanout . /OQ 'f
Sewer/septic service line Z 3l'r- Holding tank / 0 0 t
Animal containment areas ( r �
Manure/animal excrete storage areas /OO 74-
SEPTIC/HOLDING TANK ON LOT TO:
ri e e
Building foundation J 1 Property line / Q f Absorption field .s 't
Water main 7a �f Water service line / �f Surface water /0 a ,-"-
Wells on adjacent lots Q'Q
'f
ABSORPTION FIELD ON LOT TO:
Property line /0 /f' Building foundation /d r1" Water main /Q /7'
Water Service line l /tSurface water /Q C r Driveway, parking/vehicle storage /e 1
Curtain drain 5-a Wells on adjacent lots /Oa
F. COMMENTS
G. ENGINEER'S CERTIFICATION "",,
"4-el
I certify that l have determined through field inspections and ,
review of Municipal records that the above systems are in
conformance with MOA COSA guidelines in effect on this date. `_ ` :`:C=T=T -
Engineer's Printed Name .. 7 L/to�/ 6
• r
Date d z 2// 7 --
COSA yellow sheet_2-6-15,doc
sc,g-_< t we /ti c),4 F7
OT 2 11
Found
Rebar
N
% i
fNeco LOT 22� a
-:, [a 0 I,
SI' 53 SCALE
.\\ >G \ ,t � �Qi■�
0.,v� /138.38'
6
I 889'38'38V
.` 1 PCC Pad— 1
t y 3 r 32 5 Z-Love/ Wood
Frame Residence
y on Concrete Mk
,p'. Fouraa ion Mock
{
n
1
1
8.155.93' - --Well
Lw 154.46' +er d d
z 47 3557 1 �' PCC I�od :t
` ' 4 W
ce
e PCC sad
y� Post { a 6 LOT I
2' + 14.2 .
I` I Cantile+�0: al
+ tyroo.' '
deck i I
l
'35.9' •"- +.- over W.•'.r,..ug 1,k
i.
4
��� a
�i /~ ��,/ Found YPC.
O'. / on Rebar
S
v �? _ .�t�' •' 15.1' f� `�.
•
-------- �iT a Covered �eda�J 'O,
�r
r
O_+' Jd' Stora a 0.3'e- i rC
/OEa 18.8'
fit?! a wood shed N 'II-
/
o
Ij Q� No Faundat ons b
8.125.39' ^. r7e
I... 43 55' rCreon Uul ti
p- 19.5#',39. LOT 2 J (Typ r) , ci
N
fy r r1si C7
10' Uti:ty Easement Z
30. 13457• I i ....---"-21).M.
N$9.54'23*W k$9'16'5S W
LOT 15
hereey certify (not on oc;:urate survey of the tollowi^4 described PREPARED FOR
%%%%%,� °�1Qe'�Y PANNONE ENGINEERING
.+* tit Ai eft NORTH St.CPE-EKLUNG SUVA/IS/OR (2006-56)
r. :•,,.......ticJ,tO. LOT 2
..L.)/ , ' i'e ••as mode on September :2. 201, Ond that IM improwmentS A S— t �
*.-`i_fr I situated Iherenn are within the properly knVS and do not overtop or L V L T
ik_ .... .. encroach on the property tying adjacent thereto. that no
titer. tees oA$ MD
0 • nnprovements on the property tying adjacent thereto encroach on AP 4/15/20t3 SE rOJ
:y: Li.•.r.......«...;i i the aremses in question and that there ore no rpodroys. ,.�
sje-i*..•w. 71.)-I:/= l-anem.ssion t.nee or other viseble eosaments on sold property except `1£h0 F.8 2m3 'IUB "'t7
f .•..e ♦ of . d.cated hereon. Easements other than trose shown on the t ;PG.70 ,7}74
.IIBN."..1111141-Th��4 record plot moy not opoear ors this drawing
i+....• KARABEL N!K OFF
Atich.'age eloska. 10411 1 5th dor pr Tete•n*er 2013 SUR yE YI N C anf.-4.ry
Municipality of Anc
On -Site Water and Wastewater
(907) 343-7904
CERTIFICATE OF ON-SITE SYSTEMS
Parcel I.D. 050-531-36
1. GENERAL INFORMATION
A9
IM,
JUL 2 2 2015
Expiration Date: o
Complete legal description North Slope -Eklund Lot 2
Location (site address) 4123 Upper Kogru Dr, Eagle River, AK
Current Property owner(s) Krenzelok Day phone 864-6524
Mailing address same
Real Estate Agent Latosha Williams Keller Williams Day phone 864-6524
2. TYPE OF DWELLING:
N Single Family (w/wo ADU)
❑ Duplex
❑ Multiple Dwellings (Single Family and/or Duplex)
3. NUMBER OF BEDROOMS:
4
4. TYPE OF WATER SUPPLY:
TYPE OF WASTEWATER DISPOSAL:
Individual Well
®
Individual
N
Individual Water Storage
❑
Holding Tank
❑
Community Class C Well
❑
Community
❑
Public Water System
❑
Public Sewer
❑
Received by: _ � Date: 712 /S
COSA to be released to the engineer, unless otherwise requested by the engineer.
COSA Fee $ C;t(4- Date:
Date of Payment -7)2.3/1-5 Date of Payment
Receipt Number Q )q (001vz�' Receipt Number
COSA# ���cJ I�J��J Waiver
5. STATEMENT OF INSPECTION BY ENGINEER
N
A 't.
As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation,
based on procedures outlined in the Certificate of On -Site Systems Approval Guidelines for this application,
shows that the on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate
for the number of bedrooms and type of structure indicated herein. I further verify that based on the information
obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water
supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal and State codes,
ordinances, and regulations in effect at the time of installation.
Name of Firm NorthRim Engineering Phone 694-7025
Address PO Box 770724, Eagle River
Engineer's Printed Name Steve Eng Date
6. DSD SIGNATURE
_1�� System #1 Approved for _ bedrooms.
System #2 Approved for
Disapproved.
Conditional approval for
bedrooms.
bedrooms, with the following
4�
1AlATGR AND
By: Az � ( Original Certificate Date: -'c;� 9 " lit—
The Muni pality o horage Devlopment Services Division (DSD) Issues Certificates of On -Site Systems Approval (COSA) based only
upon the representations given in paragraph 5 by an independent professional civil engineer registered in the State of Alaska. The
Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work.
7. ATTACHMENTS:
COSA Checklist
Septic System Advisory
Well Flow Advisory
COSA blue sheet 9-1-12.doc
Nitrate Advisory
Arsenic Advisory
Other
If more than 1 septic system is on the lot:
COSA Checklist # of
Structure served by tois system
Certificate of On -Site Systems Approval Checklist
Legal Description: ' •-rA S41Iao_ " g�k cJvrO9 Aa Z Parcel ID: 05'0 53! 3r'
A. WELL DATA
Well type P If A, B, or C provide PWSID #
Date completed VA/ Sanitary seal (Y/N)
Total depth VAIX ft. Cased to e&k ft.
Date of test.
Static water level
FROM. WELL LOG
LAAJ K
� ft.
Well production g:p.m.
WATER SAMPLE RESULTS:
Coliform O colonies/100 mL Nitrate Z • q mg/L
Arsenic AfA ug/L Date of sample: 7/.4/�5
B. SEPTIC/HOLDING TANK DATA
Tank Type/Material Sjl5i077G'� s%EG
Well Log (Y/N) /V
Wires properly protected (Y/N)
Casing height (above ground) j2tin.
AT INSPECTION
7
31 ft.
y?'_ g.p.m.
Collected by: - /"-fA ".,. e• t_
Date installed etAI I
Tank size /2$4 gal. Number of Compartments Z Cleanouts (Y/N) X
Foundation cleanout (Y/N) * . Depression over tank (Y/N) A/ High water alarm (YIN) Al
Date of pumping A/FW Pumper
C. ABSORPTION FIELD DATA
Date installed Soil rating (g.p.d.Ift2 or fiz/bdrm) System type _ _% �ewQL
Length 301361t. Width 2. S ft. Gravel below pipe S ft.
Total depth;_; `Y ft:',��F. absorption area 'CaCI ft2 Monitoring tube Depression over field
Date of adequacy test•- Results (Pass/Fail)
Fluid depth in absorptiori'fle[d before test in. Water added gal.
Elapsed Time:'' ;ipn. Final fluid depth
Any rejuvenation treatment (past 12 mo.) (YIN & type) _
For bedrooms
New depth in.
in. Absorption rate >= g. p. d.
If yes, give date
D. LIFT STATION NA
Date installed
"Pump on" level at
Datum
Size in gallons
in. "Pump off' level at
Cycles tested
ral
Manhole/Access (Y/N)
High water alarm level at
Meets alarm & circuit requirements?
rel
E. SEPARATION DISTANCES
WELL ON LOT TO:
r
Septic tank/lift station on lot /6G r f On adjacent lots
Absorption field on lot /Os it On adjacent lots !O a '{-
Public sewer main 140 'r Public sewer manhole/cleanout Ida 'i -
Sewer /septic service line 2 S `t Holding tank la C `&
Animal containment areas S0 , f Manure/animal excrete storage areas l6 a `t
SEPTIC/HOLDING TANK ON LOT TO:
Building foundation S �f Property line /0 •f Absorption field
Water main l4 it Water service line ( O `rt Surface water / OLT `F
Wells on adjacent lots
ABSORPTION FIELD ON LOT TO:
Property line 10 er Building foundation Water main /0 `t
Water Service line /6 `f Surface water 104 I f Driveway, parking/vehicle storage
Curtain drain 56 Wells on adjacent lots
F. COMMENTS
G. .ENGINEER'S CERTIFICATION
I certify that I have determined through field inspections and
review of Municipal records that the above systems are in
conformance with MOA COSA guidelines in effect on this date.
Engineer's Printed Name S r%64/,"' C�J C
Date
COSA yellow sheet_2-6-15.doc
ED
• •�• w. W
stsren w. &W a <
ee
e�°•..7/z�is°
41
N
to
w
W
I hereby certify that an accurate survey of the following described
PREPARED FOR:
A�L��Xi1\property:
OF A� %to
q�
NORTH SLOPE—EKLUND SUBDIVISION (2006-56)
PANNONE ENGINEERING
�........... ••
F��
LOT 2
*•••ON. �0,
was made on September 12, 2013 and that the improvements
thereon
AS -BUILT
;9TH .............9
situated are within the property lines and do not overlap or
encroach on the property lying adjacent thereto, that no
"""""' ••M
improvements on the property lying adjacent thereto encroach on
oWN.
DATE
GRID
Lee KorobetnikoFF,•k0
the premises in question and that there are no roadways,
JSP
9/15/2013
SE 703
y No. 3143-5..',,
'
transmission lines or other visible easements on said property except
FILE NO.
F.B. 2013
JOB NO.
as indicated hereon. Easements other than those shown on the
1344
Pc. 70
1374
`L
record plat may not appear on this drawing.
c�
'�� �`'`
KARABELNIKOFF
Anchorage Alaska, this 15th day of September 2013
SURVEYING a.3.
Fa*r, w7
41
N
to
w
W