Municipality of Anchorage
c
On -Site Water and Wastewater Section • (907) 343-7904
ON-SITE WASTEWATER INSPECTION REPORT JU` ®04?
2
4?0
Permit Number: OSP201061 PID Number: 017-431-17
Dwelling: ❑■ Single Family (SF) ❑ with ADU ❑ Duplex (D) ❑ Two Single Family Project: ❑ New 0 Upgrade
Name
NELSON PRIDDY
ABSORPTION FIELD
❑ Deep Trench ❑ Wide Trench ❑ Bed ound
Site Address
12700 VON SCHEBEN DRIVE *ANCHORAGE, AK
❑ Other
Phone
Number of Bedrooms
Soil Rating
Total depth original grade
907-350-4685
4
GPD/SFJ
Ft.
LEGAL DESCRIPTION
Depth to pipe invert from original grade
Ft.
Gravel depth beneath pipe
Ft.
Subdivision Block Lot
GREENBROOK; BLOCK 2, LOT 9
Fill added above original gr
Ft.
Gravel length
Ft.
Township Range Section
Gravel width
Ft.
Beds: Number of Lines
Distance between lines
Ft.
SEPARATION DISTANCES
To
Septic
Absorption
Lift Station
Holding
Sewer
Total orption area
Number of trenches
Dist. between trenches
From
Tank
Field
Tank
Line
Ftz
Ft.
Well
100'+
TANK ❑ Septic 9 S.T.E.P. ❑ Holding ❑ Other
Manufacturer
GREER TANK
Capacity
1500 Gal.
Surface Water
100'+
"Z
Material
Number of compartments
Lot Line
51+
NA
HDPE
2
Foundation
10'+
LIFT STATION
Manufacturer
Capacity
Remarks OLD TANK DECOMMISSIONED PER UPC
GREER TANK
500 Gal.
PER CONTRACTOR "SECOND COMPARTMENT OF STEP TANK
Alarm location q�
EXISTING
Electrical installed by
Installer
PIPE MATERIAL House to tank D3034 Tankto
D1785
A+ HOME SERVICES
Drainfield EXISTING CO/MTEXIST6
inspector TIM ECKLUND AND DAVID GARNESS, PE
BENCH MARK (Assumed elevation) 100.00 ft
Inspection 151 6/15/2020 2�d -
Location and description
3 I _ 4th _
TOP OF MH
ON-SITE WATER AND WASTEWATER SECTION APPROVAL
Engineer's Stamp
oo�Q Q•1
Conditional Approval: Date
o� . '' TH
1p................�
.... Vl...................�
Septic System /�
Approved ��,��/i, ('(.� Date S` r0�b
000 r_ 53rness.-
09'�f I; .:-� ,� _. ;coo
Note: this approval does not include well permit requirements.
�OQQQ��Oa
#AECC884
O.y_4cd 0.S-bLL&t- 5Llj`WfA U Lira � -- wc,-Lvf -{-o 6-0-sp—
O+w, f 4, 0-1, t.sfc�.c�,-Fed
Cl ri oe � � r AJo
PERMIT NUMBER: PARCEL ID NUMBER:
OSP201061 RECORD DRAWING 017-431-17
APPROXIMATE LOCATION
OF WATER KEYBOX -
A B C
MH1 1 16.8 14.8 19.9
MH2 1 20.9 1 18.5 1 20.7
NO SURFACE WATERS WERE NOTED
WITHIN 100' OF THE NEW SEPTIC TANK
SHED
O
tissy n �\
DRIVEWAY r
r t;• .
NEW 1500 GALLON ANCHORAGE TANK EXISTING 4
HDPE STEP TANK WITH ORENCO BEDROOM
COMPONENTS. RE -USED EXISTING PANEL ---N I I HOUSE
APPROXIMATE
LOCAITON EXISTING
DRAINFIELD
DURING THE EXCAVATION OF THE IDSF, IT WAS NOTED BY THE
CONTRACTOR, ENGINEER AND MOA INSPECTOR THAT IT IS NOT IN A STATE
OF FAILURE. INSTEAD, THE HEADER HAD DISCONNECTED. IN SHORT, THE
CONTRACTOR REPAIRED THE IDSF PIPING AND IT WAS NOT RE -BUILT
GARNESS ENGINEERING GROUP, Ltd
ENGINEERING SALES CONSULTING
3701 E. TUDOR ROAD, SUITE 101 -ANCHORAGE, AK 99507 • PHONE (907) 337L179 • FAX (907) 338-3246 - WEBSITE: �. gamessengineenng.cam
PREPARED FOR: PHONE NUMBER: PAGE NUMBER:
NELSON PRIDDY 907-350-4685 2 OF 3
LEGAL DESCRIPTION: DRAWN BY:
GREENBROOK; BLOCK 2, LOT 9 D.J.G.
TYPE OF WORK: DATE:
SEPTIC TANK RECORD DRAWINGS 7/24/2020
GREENHOUSE
N
SCALE:
ia
1"=40'
PERMIT NUMBER: 0 PARCEL ID NUMBER:
OSP201061 RECORD DRAWING 017-431-17
TOP OF MANHOLE = 100.00
FINAL GRADE = 99.5-99.9
MH1 MH2
TOP OF TANK AT INTLET = 95.97
INVERT OF BUNG AT INLET = 9523
NEW 1500 GALLON ANCHORAGE TANK
HDPE STEP TANK WITH ORENCO
COMPONENTS FOR IDSF
TANK HOLE WAS DRY DURING
EXCAVATION - GROUNDWATER
WAS NOT ENCOUNTERED
2" INSULATION PER CONTRACTOR
OF TANK AT OUTLET = 95.96
kxAjKNvr_'j1SS EN(.'41_wNrr_TRK_jw1NG Gj"xuu Ltd
ENGINEERING - SALES � CONSULTING All
3701 E. TUDOR ROAD. SUITE 101 'ANCHORAGE, AK 99507 -PHONE (907)337-6179- FAX (907)338-3246 -WEDSITE —games—gin-mg,com
PREPARED FOR: PHONE NUMBER: PAGE NUMBER:
NELSEN PRIDDY 1 907-350-4685 1 3 OF 3
LEGAL DESCRIPTION: DRAWN BY:
GREENBROOK; BLOCK 2, LOT 9 D.J.G.
TYPE OF WORK: DATE:
SEPTIC TANK PROFILE 6/25/2020
� 7F
0
0....•• .. . . ............... ...... 0
# r A. Gam ss
_Q AV
# #
# 4ZAF c Ar
L 41p
12
LICENSE %FESS\
#AECC8 4 %%%Isw&
06/24/2020
10:53 8686770 APLUS
munici r, ality of Anchorage
DevelOPIM Mt Services Department
P-0- BOX 196650 - 4700 Elmore Road
Anch( rage, Alaska 99s19-6650
Info j id Help. (907) 343-8211
.r"
INSPECTIONS:
Volce: (907) 343-8300 Fax: (907) 249-7777
6/23/2020 Inspe chtion Report
License/AP#, RETROE201.,57
Parent AP#;
Inspection #: 616877
'Type: DPRETRO
Status: Closed
Address; 12700 VON S MEBEN DR
Parcel- 01743117000
Inspector: M -Green
Project:
Resp Party:
Descr: Lift station rel lacement.
Inspection Electrical (Eia stoical Inspection)
Item:
Evaluation: Approved
Result Notes, Existing contr oiler and wiring inside.
Only work w,?j to re -feed underground
from house to new Septic system.
Installation co nPlete and approved.
",spection Item Item Desc ption Evaluation
PAGE 01
MUNICIPALITY OF ANCHORAGE
On -Site Water & Wastewater Program
PO Box 196650 4700 Elmore Road
Anchorage, Alaska 99519-6650 Phone: (907) 343-7904 Fax: (907) 343-7997
http://www.muni.org/onsite
On -Site Wastewater Disposal System Permit
Permit Number: OSP201061
Work Type: Septic Upgrade
Tax Code Number: 01743117000
Site Legal Address: GREENBROOK BLK 2 LT 9 G:2839
Site Mailing Address: 12700 VON SCHEBEN DR, Anchorage
Owner: PRIDDY NELSON H II &
Design Engineer: GARNESS ENGINEERING GROUP LTD
This permit is for the construction of:
Q Disposal Field ❑ Septic Tank ❑ Holding Tank. ❑ Privy
Effective Date:
Expiration Date:
cnt
0
V f,
v
De parttnent
Lot Size in Sq Ft:
Total Bedrooms:
4/15/2020
4/15/2021
59411
❑ Private Well ❑ Water Storage
All construction shall be in accordance with:
1. The attached approved design.
2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska
Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80)
3. The wastewater code requires inspections during the installation. The engineer shall notify the Development
Services Department per AMC 15.65. Provide notification by calling (907) 343-7904 (24/7).
4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather
shall be either:
a. Opened and Closed on the same day, or
b. Covered, sealed, and heated to prevent freezing
Special Provisions: If it is determined that the septic tank needs to be replaced, a change order shall be
submitted.
4
J r SQA is 2 w �e. re P ��c� d w -e'en 15 0
mg_v\ � o_, r i � U c o
b,-\ �-o u v� . ; n — 12 -fn C (--/10' 2-) z_G
Received By: 4 17 Date:
Issued By: Date:
r
�N`IUKKIPALITY oF ANcHORAGE
c,omminity DeveibpmOnt
,department 1Phone:. 907-343-7904
Developinnent Services 'Fax: 907- 343-7997
oa,clte W.; ter.. Wastewater Program
mayor Dan Sullivan
on-site Sewer/Well Permit Application
For A Single Family Dwelling
. ,
Parcel I.D,
Property owlip(0
klall!ng address
Bite address.l.i700 VCIN SCHEGEN DPlVE'ANQ+-)RAG.E-,, AK
U :9-
egal desc6pjion 'Sub'd� Block Z Lot ) GKENSROC K, BL -CK' 2, LOT
Day phone 907-350-4885
Legal description (Township, SOIJon & Roge)
I
,,ot Size :8q.Ft. Nurnt;Or of Bedropms 4
APPLICATION IS:f OR:
❑
all o"at apply)
I
At$6rptic�n Reld
M
Septic Tank
❑
Hoiding Tank
❑
ROW
❑
Private Well
❑
V -later storaqB
F-1
APPLICATION IS AN;
Initial
❑
Renewal
TYPE OF, DEWELLING:
Single Family (SF)
(wM6 ADU'
D'upldX (0) ❑
Multiple Dwellings
(SF andlor D)
THIS APPLICATION INCLUDES A—VNRIANCEi WAIVER REQUFST.FOR:
'Distance:
I certify that the above ilifoi-mation is correct. I further certify that this is I s in accordance: With
applicable Murliciral codes,
nature of L%Wner or autnorized agent)
fyermiVRush Fees, �v%!aiver Fees.
Date of Payment.
Date --.t Payment*
Receipt Dumber. Receipt Number:
05P ZVO&t. waiver'Not
Permit No.
Municipality of Anchorage
On-site Water and Wastewater
REVIEWED FOR CODE COMPLIANCE
OSP201061, Rebecca Carroll, 04/15/20
Municipality of Anchorage
On-site Water and Wastewater
REVIEWED FOR CODE COMPLIANCE
OSP201061, Rebecca Carroll, 04/15/20
DRAINFIELD
5 FT {VIDE
30 FT LONG
I FT OF ROCK
I FT TOTAL DEP1
3 FT OF COVER
JO.00 N
Sample Access.
8 -Inch Sump
707
1500 GAL STEP TANK �•. - .. ;��
MYTH 2 -INCHES Or INSULATION
J
NO SCALE
J' Cover
/— 4' Topsoil
94.7
94.010- -0-0?0?0?00
11' Sewer Rock —
4" Distribution Pipe
Aliroli 140 -
U0UQU
97 1 1 7/30/94
I 02
1500 rol STEP J
BENCH MARK:
BOTTOM SIDING
ASSUMED ELEV. 100.00 FT
1088EN SPURKLAND P.E. LOT 9 FLOCK 2 GREENBROOK SEPTIC SYSTEM ASBUILT
203 V115th Ave11
DATE: OCTOBER 18, 1994
Ancho,o a Ak 99501 11700 VON SCHABEN
9f ERICKA KRAMER SHEET: 414 GRID: 2637
0
z
L
Q
\C3
z
LLJ
\\\(
§
��
�
�
tZ
LU
I
cl)
z
L
z
IntermittantSand Filters Manual
SAND FILTER CONFIGURATIONS
2X4 e
PLYWOOD
BOX
FROM
S.LE.P
TANK
FROM AIR
COMPRESSOR
40 PVG LATERAL VV 1/6"m ORIFIGE
OR� SHIELD
I I
/' `� 1
I 1 I 1
I I I I I 1
I
I 1 I I I I I I
I I I I I I I I
I I I 1 I 1 1 1
I I 1 I I I I I
I I I
I 1 I I I 1 I
COIL BELOW i
/ I
FLU5HING VALVE E ENCLOSE
-----------------------
TOP VIEW
18 x 20 BOTTOMLESS SAND FILTER
Municipality of Anchorage ,.
Development Services Department E E`•;
Building Safety Division
On-Site Water & Wastewater Program. 4700 Bragaw St.
P.O. Box 196650 Anchorage. AK 99519-6650
www.cl.anchorage.ak.us (907) 343-7904 Page 1 of 3
On-Site Wastewater Disposal System and/or Well Inspection Report
017-431-17
Permit Number. SW070183 PID Number.
Name: Wastewater System: [3New ■ Upgrade
THOMAS KRAMER
Address:
2551 LOUSSAC DRIVE a ANCHORAGE, AK 99517
ABSORPTION FI
Phone: No. of Bedrooms:
4
Cl Deep Trench ■ Shallow Trench O Bed a Mound a Other
(907) 250-0090
LEGAL DESCRIPTION
SW Ral'•q: Total a•pth Iran orfilnal pod•:
4 WD/se. rt SEE DWG. rt.
Block: Lot: Subdivision:
aplh f. p" bottom ban "lnal pod•:
Gravel depth trd•aln pip. 0.5
2 9 GREENBROOK
SEE DWG. rL
rti
Township: Range: — Section: —
f7 odd•d •Care adpnal pod•:
SEE DWG. In.
Gravel tonal
30 ^.
—
uar.f waU,:
NwMr a w.: Owlanp e.tw«n dn..:
15
WELL: ❑ New ❑ UpgL
5 rL
2 n
ca..rca4on pdM., A.B.c : Tara/ G.p.1
Taal olwaptan onm
150
Plp• L 3034/ F-810
rt
so. n
pw..: oat. prYc
wsla••r:
ARCTIC MOUNTAIN DEVELOPMENT
Dote was
8/21-24/2007
L
rww:
.wrw s.t AL
d:
TANK
GPU
r<L
SEPARATION
DISTANCES
aseptic 0Holdinq ■S.T.E.P. 0Othere
AbsorptiongUft1lTo,1dna/f'rlrot•
karwloctanr.
ANCHORAGE TANK
eToSeptic
1500From
Tank
Field
wer lYw•�,tefly,o
F�-'aon�pavrenw:
Well
200'+
200'+25'+
STEEL
2
Surface water
100'+
100'+—
LIFT STATION
slot Mq•••n . wonvfacta ..Lot
Una
5'+
10'+—
1500 ANCHORAGE TANK
en wr ol: anp aft wvo •l: Kqh water darn dl:
Foundation
5'+
10'+
5'+
—
—
TIMER TIMER 46
P.M Lia.. e[ Yadek
tLaulad kwp•ctarw pwfamwd Ot: /a
Curtain Drain
NONE KNOwN
/20 OSI 05 HHF
I
BENCH MARK
Remarks: OLD S.T.E.P. TANK WAS PUMPED AND
tacatan ons a.«rgtan:
TOP OF ELECTRICAL CONDUIT ON HOUSE
FILLED WITH SOIL.
SOUTH WEST CORNER.
A•.an.d Ewrakon: 103.50 n
ENGINEER7e L
Inspections performed by: GEG, Ltd. Dates: 1st 8/21/2007
,moo
o �F Op
2nd 8/21/2007
3rd 8/24/2007
.• X000
Development Services Department Approval
....:....• • ......•. .......00
D
Conditional approval: Date:
0 .... f y . Gam ss:
QQO yJ • • CCE— 53
Day oll,
/ —
G�04
Date: d
Reviewed and approved by:
o
�Op0000�oo�
(R.. 4/oe)
PERMIT NUMBER: AS -BUILT DRAWING PARCEL ID NUMBER: 017-431-17
I
SW070183
NEW 1500 GALLON
S.T.E.P. TANK
100' POND
SET BACK -
GENERAL LOCATION OF
FOUNDATION DRAIN
(SOLID PIPE)7
DRAINFIELD
PIPE FROM DRAIN DAYLIGHTS OUT IN
THIS AREA. NO WATER FLOWING FROM
PIPE.
1
EXISTING 4
BEDROOM
HOUSE SERVED BY ALL CO AMUN7ITYSWATER SYSTEM
FLOW SPUTTER
EXISTING
r /I X tB
LSF
SP
EXISTING
DRAINFIELD
G_ARNGSS LNGINLLRING GROUP, Ltd.
-•.., CONSULTANTS & GENERAL CONTRACTORS �-•�
POI L 1110Ce IIYD. !A[ IOL • /WEAN.[. X ~ • r1E1[ 1euf�vr-eIT • r" (902$L " • 11 - ew.eAerWr�Y+AA
PREPARED FOR: PHONE NUMBER: PAGE NUMBER:
THOMAS KRAMER 250-0090 2 OF 3
LEGAL DESCRIPTION: DRAWN BY:
GREENBROOK SUBDIVISION. LOT 9. BLOCK 2 DATE: K.D.M.
TYPE OF WORK: 9/4/200
AS -BUILT DRAWING
(Rev. 01105)
. ...
......
A ......
Je f y . am ss.
�Q°or -79 ' FFG
A
B
C
ST1
59.94
17.63
45.62
ST2
61.22
22.08
53.41
MH
62.54
22.73
54.98
SP
92.61
26.38
19.72
C01
107.18
38.72
68.97
MT1
105.42
36.51
66.97
CO2
129.03
53.45
69.82
MT2
127.84
52.35
68.38
CO3
125.46
49.80
57.23
MT3
124.28
48.61
56.68
C04
93.08
24.50
22.73
C05
94.35
126.051
22.65
NEW 1500 GALLON
S.T.E.P. TANK
100' POND
SET BACK -
GENERAL LOCATION OF
FOUNDATION DRAIN
(SOLID PIPE)7
DRAINFIELD
PIPE FROM DRAIN DAYLIGHTS OUT IN
THIS AREA. NO WATER FLOWING FROM
PIPE.
1
EXISTING 4
BEDROOM
HOUSE SERVED BY ALL CO AMUN7ITYSWATER SYSTEM
FLOW SPUTTER
EXISTING
r /I X tB
LSF
SP
EXISTING
DRAINFIELD
G_ARNGSS LNGINLLRING GROUP, Ltd.
-•.., CONSULTANTS & GENERAL CONTRACTORS �-•�
POI L 1110Ce IIYD. !A[ IOL • /WEAN.[. X ~ • r1E1[ 1euf�vr-eIT • r" (902$L " • 11 - ew.eAerWr�Y+AA
PREPARED FOR: PHONE NUMBER: PAGE NUMBER:
THOMAS KRAMER 250-0090 2 OF 3
LEGAL DESCRIPTION: DRAWN BY:
GREENBROOK SUBDIVISION. LOT 9. BLOCK 2 DATE: K.D.M.
TYPE OF WORK: 9/4/200
AS -BUILT DRAWING
(Rev. 01105)
. ...
......
A ......
Je f y . am ss.
�Q°or -79 ' FFG
INSULATION- FINAL GRADE - 101.23-101.77
STI
ST2 MH
TOP OF TANK Q q
AT INLET - 98.08 -1 I I I I
NEW 1500 GALLON
INVERT OF BUNGS.T.E.P. TANK
AT INLET - 97.48
- TOP OF TANK
AT OUTLET - 98.08
MOUNDED DRAINFIELD FINAL GRADE - 100.32-100.44
TOPSOILED AND SEEDED INVERT OF PIPE - 97.62
LIT CO INSULATION
LTER FABRIC
TOP OF SAND - 96.98
r --ORIGINAL GRADE - 96.98
V DEEP MAX
2' TO H2O
L
S' WIDE �1
1' DEEP MAX
I
GARNES_S ENGINEERING GROUP, Ltd. ��` ,r.
CONSULTANTS 6 GENERAL CONTRACTORS----rte--� "'• •" '•
3A1 G TAM 0010. RA[ 101 . N{1101400. M M001 �ttd[ (OOf)}0f" • LAI (907)3 N - � w�.
PREPARED FOR: PHONE NUMBER: PACE NUMBER: E , •,J . e .... ..
THOMAS KRAMER 250-0090 3 OF 3 QOo
LEGAL DESCRIPTION: DRAWN 8: O r� E 5 09,•'
GREENBROOK SUBDIVISION, LOT 9, BLOCK 2 K.D.M. �0 ,e • 9 ... • �o
TYPE OF WORK: DATE: ��QO4p�OOOoc'�
AS -BUILT PROFILE DRAWING 9/4/2007
(R.. 01M)
MUNICIPALITY OF ANCHORAGE
Development Services Department
On -Site Water & Wastewater Program
4700 South Bragaw Street
P.O. Box 196650, Anchorage, AK 99519-6650
(907) 343-7904
ON-SITE WASTEWATER DISPOSAL SYSTEM PERMIT
Upgrade
F -a-1-0-4 10-"
8-,2.1-07 &, 3: 30
Date Issued: Jul 31, 2007
Expiration Date: Jul 30, 2008
Permit Number: SW070183 Parcel ID: 017-431-17
Legal Description: GREENBROOK BLK 2 LT 9
Design Engineer: 0855 GARNESS ENGINEERING GROUF Site Address: 012700 VON SCHEBEN DR
Owner Name: THOMAS KRAMER Lot Size: 59411 SO. FT.
Owner Address: 2551 LOUSSAC DRIVE Total Bedrooms: 4 Permit Bedrooms: 4
ANCHORAGE. AK 99517 -
This permit is for the construction of:
❑✓ Disposal Field ❑ Septic Tank ❑ Holding Tank ❑ Privy ❑ Private Well ❑ Water Storage
All construction must be in accordance with:
1. The attached approved design.
2. All requirements specified in Anchorage Municipal Code Chapters 15.55 and 15.65 and the State of Alaska
Wastewater Disposal Regulations (18AAC72 ) and Drinking Water Regulations (18AAC80 ).
3, The engineer must notify DSD at least 2 hours prior to each inspection. Provide notification by calling
(907) 343-7904 ( 24 hours ). ( Not required for a Water Supply Permit only ).
4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather
must be either: A. Open and closed on the same day.
B. Covered, sealed, and heated to prevent freezing.
-5/-m/o7 SKSAn C^&A in. Tnk Aas Fa �eA &J Wil( b- rV11 K. CJ:iecG Tor-
elec.+.foal i1�s�peLf�bn,
Received By.
Issued By.
Date: % 7
Date: —T3' J 7
Municipality of Anchorage
Development Services Department
Building Safety Division+
On -Site Water & Wastewater Program
4700 Bragaw St.
P.O. Box 196650
Anchorage, AK 99519-6650
www.ci.anchorage.ak.us
(907) 343-7904
ON-SITE SEWER/WELL PERMIT APPLICATION
FOR A SINGLE FAMILY DWELLING
Parcel I.D. 0/5 - t43) -%T
Property owner(s) THOMAS KRAMER Day phone C/o
Mailing address 2551 LOUSSAC D eD ASE AK
Site address _14 ( fj� S&L -7262) Zip Code 99517
Legal description (Sub'd, Block & Lot ) _ G
Legal description (Township, Section & Range)
Lot Size 59. q/1 Sq.Ft.
THIS APPLICATION IS FOR IS all that apply):
Absorption Field
❑
Septic Tank
❑
Holding Tank
❑
Privy
❑
Private Well
❑
Water Storage
❑
Number of Bedrooms
THIS APPLICATION IS AN:
Initial
❑
Upgrade
S
Renewal
❑
certify that the above information is correct. I further certify that this application is being made for a
Single Family Dwelling and is in accordance with applicable Municipal codes.
GARNESS ENGINEERING GROUP Ltd.
Permit/Rush Fees: Y (_9 - O
Date of Payment: 7/.2
Receipt Number: <4C)a-57
(Rev. 11/05)
Waiver Fees:
Date of Payment:
Receipt Number:
GARNESS ENGINEERING GROUP, Ltd.
a _ CONSULTANTS & GENERAL CONTRACTORS � "'
July 20,2007
Municipality of Anchorage
Development Service Department
On -Site Water & Wastewater Program
4700 Bragaw Street
P.O. Box 196650,
Anchorage, Ak 99519-6650
(907)343-7904
Ref: Proposed Drainfield Upgrade for Greenbrook Subdivision; Lot 9, Block 2,
To whom it may concern:
The existing 4 bedroom house is served by a community water system and private septic system. The
septic system consist of a lined ISF with a secondary drainfield. The ISF is in good condition, but the
drainfield is only capable of absorbing 225 gallons per day. We are proposing to install a 5 -wide trench
type drainfield immediately downhill from the existing drainfield. The drainfield will be designed around
the 30 foot radius of Toben Spurkland P.E.'s 1994 test hole. Comments regarding the design are
summarized as follows:
1. DRAINFIELD DESIGN: See attached design drawing for drainfield specifications.
2. SURFACE WATERS: There is a pond approximately 115 feet downhill from the proposed septic
system.
3. TOPOGRAPHY: As can be seen on the attached design drawing the average topography below the
drainfield is a 9-10 percent slope running approximately northeast to southwest.
We are unaware of any adverse impacts this installation would have on adjacent wells or septic systems.
If you have apylquestions, please contact us at 337-6179. Thank you for your assistance.
.E., M.S.
NOTA 71 ttached is a site plan drawing, a design drawing, one soil log, which are all part ofthe design package for
this septic system. (Contact G.E.G. Ltd. for 7 page construction specification letter.)
3701 E. Tudor Road, Suite 101 *Anchorage, AK 99507-1259
Ph: (907) 337-6179' Fax: (907) 338-3246' Website: www.gamcsscnginccring.com
CREENBROOK
SUBDIVISION. LOT
6, BLOCK 4
CREENBROOK
SUBDIVISION, LOT
J, BLOCK 4
CREENBROOK/
SUBDSUBDIVISION.SIONSION.LOT
V O,S. BLOCK 4
^, P
SUBDIVISION,
BLOCCREENBRK OK
NOTE: ALL PROPERTIES
SHOWING ARE SEVERED BY
COMMUNITY WATER SYSTEM
GREENBROOK
SUBDIVISION. LOT
10, BLOCK 2
\ CIS
\ \
\ \ POND
CREENBROOK
SUBDMSION, LOT
12, BLOCK 2
I
I
I
CREENBROOK
SUBDIVISION. LOT
1, BLOCK 4
EXISTING 4
BEDROOM
HOUSE
SOUTH PARK [
Do'
CREENBROOK
SUBDIVISION, LOT
' • 7, BLOCK 1
PROPOSEDASEPTIC
:PBC SYSTEM ��
GREENBROOK
SUBDIVISION. LOT
8, BLOCK 2
HPLC
GARNGSS ENGINEERING GROUP, Ltd.
CONSULTANTS & GENERAL CONTRACTOR$ •""'. """' ..........
Al E TAM IIo.D, AA[ f01 ••uA,APMi% IM roto 7aa2u • �- .... . 0
PREPARED FOR: PHONE NUMBER: PAGE NUMBER: • • trer
THOMAS KRAMER C/0 1 OF 2 e y rness:
DRAWN BY: Qpp, . �•
LEGAL DESCRIPTION: K.D.M. p��� 1zb/�`l O
GREENBROOK SUBDIVISION, LOT 9. BLOCK 2 cgp
TYPE OF WORK: DATE: 4OQO4Ofessl c�
PROPOSED SEPTIC SYSTEM DESIGN 7/20/2007
1R�.01,05)
NUMBER OF BEDROOMS:4
GALLONS PER DAY (CPD): 600
PERCOLATION RATE/S: 10 MIN./INCH
PROPOSED APPLICATION RATE:4 GPD/S
MINIMUM DRAINFIELD SO.FT.: 125
DRAINFIELD DESIGN:
MAXIMUM DEPTHA FEET
WIDTH:5 FEET
LENGTH:30 FEET
M.O.A. APPROVED SAND FILTER:1 FEET
EFFECTIVE:0.5 FEET
.REDUCTION FACTOR:N/A
ACTUAL SO.FT.:150
LETTER THAT PERTAINS TO THIS DESIGN.
TO OBTAIN A COPY OF THE LETTER
CONTACT GEG. BY PROCEEDING FORWARD
WITH THIS INSTALLATION. THE ENGINEER,
WELL DRILLER, CONTRACTOR AND
PROPERTY OWNER AGREE THAT THEY
HAVE READ THESE SPECIFICATIONS AND
AGREE TO ACCEPT THE TERMS AND
EXISTING 1500 S.T.E.P. TANK WILL BE
INSPECTED FOR STRUCTURAL INTEGRITY
DURING CONSTRUCTION
100' POND
SET BACK'
EXISTING 4
BEDROOM
HOUSE
u
Y \ EXISTING
\\ � \ �DRAINFIELD
NOTE: THE CONTRACTOR SHALL HAVE THE
SOUTH LOT UNE AND 100' POND SET
BACK MGGED BY A REGISTERED LAND
SURVEYOR PRIOR TO CONSTRUCTION.
NOTE: ALL PROPERTIES SHOWN ARE
SERVED BY COMMUNITY WATER SYSTEM
MOUNDED ORAINFIELD SMALL BE
TOPSOI FD AND SEEDED
EXISTING
20X 16
ISF
i
(7SEPTIC
AREA
(:�SEPTIC
ARE 3
GARNESS ENGINEERING GROUP, Ltd. p°( "4 ::
—
CONSULTANTS d GENERAL CONTRACTORS "'
gni L nua Aow, furta• woa�•cc wway • wat l•o�W�-�» • nx Lb�}vs-at•a . �osic ....w�.••M•..•+a� 0 ...
PREPARED FOR: PHONE NUMBER: PAGE NUMBER: O .•� r y rness-
THOMAS KRAMER C/0 2 OF 2 CE -7953
LEGAL DESCRIPTION: DRAWN BY: OO r `ipG
GREENBROOK SUBDIVISION, LOT 9, BLOCK 2 K.D.M. ��ado
DATE: 4�D000000��6�
TYPE OF WORK: 00%
7/20/2
PROPOSED SEPTIC SYSTEM DESIGN
(R.. 01105)
y'
Gon±t�ut
I I
I I
I
GREENS K GREENSROOK I I
SUBDIVISION LO SUBOMSION. LOT I I
8. BLOC 4 J. BLOCK 4 I I
I I
CREENBROOK
SUBDIVISION. 0
4
y S. BLOCK I I
GREENBR00 I I
sue SION.
T
2. BLOCK
/ NOTE: ALL PROP T
�\ n SHOWING A E S R D Y
COMMUNI WATE S ST
I I
\ I
I
I
GREENBROOK I
BO 9LIOCK L20T GREE ROOK
Q $USD 1. LOCK 40T I I
I
G C e,2 ISTING 4 I EDROOM
OUSE
\ \
LITH PAR R
POND
\ Too,
\\ \ I
GREENBROOK I
SUBDIVISION, LO
\ 7, BLOCK 1
1
A
ncPoSPROPOSED
mT CFE EA
EDE ARI
1
GREENBROOK REE ROOK
SUBDMSION, LOT 5 DM [ON. LOT t\
12. BLOCK 2 B K 2 I
S
I I
I I I 1• 100
I I I
I I I
I I _
_o �4
F • �F "' '9S��
GARNI?'SS ENGINEERING GROUP, Ltd- p; 4 :�e�p
_...... _...__- CONSULTANTS 6 GENERAL CONTRACTORS �••�'��•-� ^-""^' �""""'
101 L TAOR IIGO. f1IR 101 . IMOgMO[. YI Nl01 1110MC (Y011111-�1A ra M
PREPARED FOR: ONE NUMBER: PAGE NUMBER: •'•':
THOMAS KRAMER PHC/0 1 OF 2 QQ o y A. Gar ess:
DRAWN BY: 0 E-79753 \�Ov
LEGAL DESCRIPTION: / '•.�I . 0,0
GREENBROOK SUBDIVISION, LOT 9, BLOCK 2 K.D.M. �� e�e� `7 -.0.9
DATE:
TYPE OF WORK: ���O�Ooo��oo.
TOPO 7/20/2007
(Rev. 0IM5)
(ENGINEER'S SEA4)..
Municipality of Anchorage
DEPARTMENT OF HEALTH &HUMAN SERVICES
825 "L" Street, Anchorage, Alaska 99502-0650
SOILS LOG — PERCOLATION TEST
PERFORMED FOR: ER ,Q< '/ .A �`'�RSAMr-- V, DATE PERFORMED:
LEGAL DESCRIPTION: L. b+� Q� a � I -- - U Township. Range. Section:
sl nPP SITE PLAN
- Loa.,- i
1
2
3 S; It 7 7: -5 4`!
z
4 •' Sorer
5 Si �-
7 -i 130 iio•..v1 -'E- �io �e
8-
91011 9-
10-
11
12-
13-
14-
15-
16-
17-
18-
19-
20
21314151617181920
COMMENTS
WAS GROUND WATER T
ENCOUNTERED?
�I
IF YES. AT WHAT
DEPTH?
Depth to Water After 37 $ o
Nnnilnrinn7 O71C I
PERCOLATION RATE I r) (mmutes/imh) PERC HOLE DIAMETER b
TEST PUN BETWEEN -.91-L FT AND .3 I -T
PERFORMED BY: 1 S I �I CERTIFY THAT THIS TEST WAS PERFORMED IN
ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE. DATE:
`P., e,. 30.9 Y
72-008 (Rev. 4/85)
Municipality of Anchorage Page I of
DEPARTMENT OF HEALTH AND HUMAN SERVICES
ENVIRONMENTAL SERVICES DIVISION ��/ZJ
P.O. Box 196650 • Anchorage, Alaska 99519-6650 • Telephone: 343-4744
On -Site Wastewater Disposal System and/or Well Inspection Report
Permit Number: c—k (l 4q V I I V PID Number: 011— 4 5" 11
Name:
Wastewater System: ❑ New �pgrade
l/. Rs�a M — O S
Address:
ABSORPTION FIELD
Phone:
No. of BleId''rooms:
L
��¢¢
O Deep Trench Shallow Trench ❑ Bed M Mound Av&her
LEGAL DESCRIPTION
Soil Rating:
Total OeDln from original grade:
GPD/Sq Ft
Lot: Block: Subdivision:m
Depth to pipe bottom f ooriginal grade:
Gravel depth beneath Pipe (o r,
t"6Y%,e I-
Ft.
Ft.
Township:
Range:
Section:
Fill added above Original grade:
?j t
Gravel length:
3 O
Ft
Ft.
WELL: [3 New ❑Upgrade
Gravel width: _
Number of lines:
Distance between fines:
I
S FL
I
Ft.
Classification (Private. A.B.C):
Total Depth:
Cased To:
Total absorption area:
Pipe material:
Fl.
I Ft.
I t7 SO. Ft.
F 63 1 0
Driller:
Date Drilled:
sUbc Water level:
Installer: C_/lir(_tom
Date installed: y./3a 4
Fs.
Yield:
Pump set at:
Casing Height Above Ground.
TANK
GPM
I Ft I
Ft.
SEPARATION
DISTANCES
�/
0Septic OHolding yt,S.T.E.P.
To
septic
Abaorplion
Lift
Hotding
ubhc/Prlvala
Manufacturer:
7-At11L
Capacity In gallons:
l.aJ V'a
From
Tank
Fiald
stabon
Tank
sewer Linea
ArAe,il-
_
Material: ' n
s
Number of Compartments:
Well
N o
AM
f Cfi 1
FeGX
SurfaceLIFT
I3�—
STATION
Water
lZ D
LotSize
in gallons:
Manufacturer:
Line
too
1.5—
"Pump on" level at:
"Pump off' level at:
High water alarm at:
Foundation
15
Z.O
_
4:
Curtain
Pump Make B Model Electrical Inspections � gerformed by:
.
Drain
L) 1"I
c_n
BENCH MARK
Remarks:
��/s
s C7.airX a ✓ ��C
Location and Description:
sem/ a 1l
Assumed Elevation: 610
SEAL
_„ENGtNEER'S
ls
Inspections performed by: S Dates:21
Department of Healand H an Services approval
='° • . v
Date: A_
Reviewed and approved by:
72-013 (Rev. 411( MOA 25
SWING TIES:
AC 16
r 53 1300 GAC
A£ 27
BC 19
-LEV, 100.00
N OF SIDING
AF 38 1
BF 14r !8 X 10 SAND FILTER
AD 49 � 1
BD 37 —
5 X 30 ABSORPTION BED
or o'7� 1•lx /�1
�C7 %fir .\ �.,, �� r^p`•� ip
Fr r.t-.s:u•4�ond
25 0 25 50 75 100 125 150
SCALE: 1' = 50 FT
ITOBBEN SPURKLAND P.E. LOT 9 BLOCK 2 GREENBROOK SEPTIC SYSTEM AS8UILT
203 W 15TH. AVENUE 12700 Von Scheben DATE: OCTOBER 18, 1994
ANCH. AK. 99501 £rlcko Kromer 11 SHEET: 2/4 GRID: 2839
From STEP
SANFL
Air Line
FINAL GRADE SLOPE 5+1
`--- 21 Insulotlon all sides, top and bottom
TOP VIEW
TOBBEN SPURKLAND P.E.
203 W 15TH. AVENUE
ANCH. AK. 99501
111x20 SAND FILTER
LOT 9 BLOCK 2 GREENBROOK
ERICKA KRAMER
SEPTIC SYSTEM ASSUILT
DATE: OCTOBER 9, 1994
SHEET: 3/4 GRID: 2839
PEA GRAVEL
I
-o=o'o 0-.!oro':oro=o�oYo':oro':o�oYo':oto'o�o'o':o�o': opo_
j
5,
•'•
Fll ter ZaiA%' `
SOV O�O�O�O�O�O�O�O�O�OVO�O�O�O�O�O�O�O�O�OV O�O�O�OVO
rte�----
FEA GRAVEL
•.. a •" ••• ^; r
t %
C c„1• Tul! .n S;:a:N and
SIDE VIEWt�.
". "':`' '>>d
TOBBEN SPURKLAND P.E.
203 W 15TH. AVENUE
ANCH. AK. 99501
111x20 SAND FILTER
LOT 9 BLOCK 2 GREENBROOK
ERICKA KRAMER
SEPTIC SYSTEM ASSUILT
DATE: OCTOBER 9, 1994
SHEET: 3/4 GRID: 2839
L. 50.00 /I
of
DRAINFIELD
5 FT WIDE
30 FT LONG
1 FT OF ROCK
1 FT TOTAL DEPT
3 FT OF COVER
1500 CAL STEP TANK
WITH 2 -INCHES Or INSL
D
Sample Access.
8—Inch Sump
NO SCALE
J, Cover
/— 4" Topsoil
94.7
94.0 �U�U�UUUOU�U U
12" Sewer Rock
4" Distribution Pipe
Miro/i 140
1021
J 94.7
b OVOVOV 94.0
92 I �? 7/30/91 . - .. .
97.4
1500 Cal STEP J
BENCH MARK.•
BOTTOM SIDING
ASSUMED ELEV. 100.00 FT
I TOBBEN SPURKLANO P.E. LOT 9 BLOCK2 GREENf1R0OK SEPTIC SYSTEM ASBUILT
103 W15th Ave 12700 VON SCHABEN 11
DATE: OCTOBER 18, 1994
Anchorage Ak 99501 ERICKA KRAMER SHEET. 4/4 GRID: 1637
. _ r. �'f,•.;...,: 1..,. X1.1. "f tl:i '�.f :'-.. � {i.� �I1;;
ii�l:l 1. f, 11•tii.' - _ � .. .. t: •'
TNSf'TCTIi)N:: li S[(..• S(.� 'l:l.11:(S• fOtr 07)7x;(,-
tfF.: 1.LARRY.l1tSi ;'1. Ir7'f
NA #: n4 8A('4
NAME: LAI^.700 t'A'!, t!F:1^t: I:T'!r p{'••tli, is 344-51x0
LOT: 0 1:1.0cl.. ., ;Jr•,: : i Nfrrrn0l ifal'C: ]p/ 4lIO�a
COMMENT: PLS CONTACT f;il'd:. AT .."``^^O F/4
- - - - -...--- _.. -
TYPE OF INSPECTION: ELECTRICAL P.OUGFI
0 0
0 0
----------------------------------------------------------------
9-S NO NONCOMPLIANCE OBSERVED C ] CORRECTIONS ESSENTIAL AS �.
EXPLAINED BELOW
C ] WILL REEXAMINE AT NEXT INSPECTION C ] DO NOT CONCEAL UNTIL REINSPECTED
---------------------------------------------------------------------------
COMMENTS:
_
INSPECT --:DATE
, - l�-_ /
------------------------------ - -
WHEN COkkECTIONS AkE MADE. PLEASE CALL FOR INSPECTION
DO NOT REMOVE THIS NOTICE
PAGE 1 OF 2
MUNICIPALITY OF ANCHORAGE + Sr 9 ►Li Cz ►b o a
DEPARTMENT OF HEALTH AND HUMAN SERVICES
P.O. BOX 196650, 825 "L" STREET, ROOM 502
ANCHORAGE, ALASKA 99519-6650
ON-SITE WASTEWATER DISPOSAL SYSTEM (UPGRADE) PERMIT
PERMIT NUMBER:SW940310 DATE ISSUED: 8/22/94
DESIGN ENGINEER:TOBBEN SPURKLAND, P.E. EXPIRATION DATE: 8/22/95
OWNER NAME : KRAMER THOMAS K
OWNER ADDRESS:12700 VON SCHEBEN DR
ANCHORAGE, AK
PARCEL ID:01743117
LEGAL DESCRIPTION: GREENBROOK BLK 2 LT 9
LOT SIZE: 59411 (SQ. FT.)
NUMBER OF BEDROOMS: 4 THIS PERMIT: 4
THIS PERMIT IS FOR THE CONTRUCTION OF:
DISPOSAL FIELD /SEPTIC TANK SYSTEM
ALL CONSTRUCTION MUST BE IN ACCORDANCE WITH:
1. THE ATTACHED APPROVED DESIGN.
2. ALL REQUIREMENTS SPECIFIED IN ANCHORAGE MUNICIPAL CODE CHAPTERS
15.55 AND 15.65 AND THE STATE OF ALASKA WASTEWATER DISPOSAL
REGULATIONS (18AAC72) AND DRINKING WATER REGULATIONS (18AAC80).
3. THE ENGINEER MUST NOTIFY DHHS AT LEAST 2 HOURS
PRIOR TO EACH INSPECTION. PROVIDE NOTIFICATION BY
CALLING 343-4744 (24 HOURS) .
4. FROM OCTOBER 15 TO APRIL 15 A SUBSURFACE SOIL
ABSORPTION SYSTEM UNDER CONSTRUCTION DURING FREEZING
WEATHER MUST BE EITHER:
A. OPENED AND CLOSED ON THE SAME DAY
B. COVERED, SEALED AND HEATED TO PREVENT FREEZING
5. THE FOLLOWING SPECIAL PROVISIONS.
SPECIAL PROVISIONS:
THE SAND USED IN THE FILTER SHALL BE CENTRAL PAVING PRODUCTS
ROAD SAND WITH LESS THAN 1t PASSING THE #200 SIEVE AND LESS
THAN 3% PASSING THE #100 SIEVE.
THE ATTACHED HOMEOWNER'S AGREEMENT SHALL BE PART OF THIS
MUNICIPALITY OF ANCHORAGE
DEPARTMENT OF HEALTH AND HUMAN SERVICES
P.O. BOX 196650, 825 "L" STREET, ROOM 502
ANCHORAGE, ALASKA 99519-6650
PERMIT.
FOUR MANDATORY INSPECTIONS BY DHHS PERSONEL WILL BE
CONDUCTED DURING CONSTRUCTION. THESE WILL OCCUR AT:
Al WHEN THE FILTER IS FRAMED AND THE UNCOVERED LINER IS IN
PLACE.
B) AFTER THE AIRLINE IS INSTALLED, BUT NOT COVERED.
C) AT THE TIME OF THE PRESSURE TEST OF THE DISTRIBUTION
LINES. n
D) AFTER FINAL GRADING.
RECEIVED BY:
ISSUED BY
M
PAGE 2 OF 2
DATE • �! z i R
DATE • 2 3 9
T.SPURKLAND P.E.
203 W 15th. Avenue, Suite 203
ANCHORAGE, ALASKA 99501
(907) 279-3916
Fax (907)-276-6013
SEPTIC SYSTEM DESIGN
LOT 9 BLOCK 2 GREENBROOK
ERICKA KRAMER
Ground Water at 3 ft.
Use ORENCO Sand Filter
with 5 -wide absorption trench
Insulate all components.
Soil Rating. From test 2/17/94
10 min/in = 4 gal/sq. ft
Required Area per Bedroom:
150/4 - 37.5 sq.ft..
Number of Bedrooms 4
Length of Trench 407.5 /5 = 30 [feet]
SYSTEM CONFIGURATION
ORENCO SAND FILTER
1500 GAL STEP
5 -WIDE TRENCII
TOTAL LENGTH 30 FT.
TOTAL WIDTH 5 FT.
TOTAL DEPTH I FT.
ROCK DEPTH .5 FT.
COVER 3 FT.
. %9
c:-.225
The installation of this septic system will not prevent wells from be installed on the adjacent lots.
There are no developed or natural surface / sub surface drainage courses on this or the adjacent lots.
The proposed septic system will not change the general slope of the area. Ponding and/or concentration of surface runoff
will not result from this installation.
Septic System Design
Lot 9 Block 2 Greenbrook
Municipality of Anchorage
" DEPARTMENT OF HEALTH & HUMAN SERVICES
825 "L" Street, Anchorage, Alaska 99502-0650
SOILS LOG — PERCOLATION TEST
PERFORMED FOR: ERICA DATE
: (ENGINEERS SEAL)
.. a'
.•........•. ••. - r
TcL:.r, F •,r(Un� • • wok
CE 2225
LEGAL DESCRIPTION: I—O} 9 Q V1'eZ ecw l - e k Township, Range, Section:
SLOPE SITE PLAN
rET LG W7+1
1
2 /
z
3-
4-
6"
6' V O T70'+�•�. 4 U e'l_
7
8-
9-
10-
11 91011
12
13
14
15
16
17
18
19
20
COMMENTS
WAS GROUND WATER —-
ENCOUNTERED?
y'
IF VES, AT WHAT
DEPTH?
Mani to Water After
Mnniln' —s
rino? � 07IC j 009
E�
7=�=-M�MNOM
...
���t�51i�l►1J��
PERCOLATION RATE _1.0.— (minutesimch) PERC HOLE DIAMETER b
TEST RUN BETWEEN —&21— FT AND —3 FT
PERFORMED BY: �r_ S 1 �7_7 CERTIFY THAT THIS TEST WAS PERFORMED IN
ACCORDANCE WITH ALLSTATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE. DATE.
30,9L4
72-008 (Rev. 4,85)
\\ / Lara
S
I
LOT 2 � I
LOT 10
o
.l
\' \ LOT 1
O �
i
\ souI P Rte —
9 1 i
1
I FF
\v
V� LOT 8
N
v
50 0 50 100 150 200 250 300
LOT 7
Tj,b sp 7kI
ce- 'is :c
SPURKEAND P.E.
LOT O BLOCK 2 CREENQROOK
SEPTIC
SYSTEM
DESIGN
ITOBBEN
203 W
15TH. AVENUE
11700 Von Schehen
DATE:
11
June 8,
1994
ANCH.
AK. 99501
Ericka Kromer
SHEET:
1/4
GRID: 2839
8
/ /9955.9
/ EXIST. TRENCH
Pat J 9- 5 ,? /977 6 :
EXIST. TANK
,9 94.1
/
1500 GAL ST
18X20 ORENCO FIL T R • B
95,rn
A
5X30 DRAIN FIE_
LEGEND:
0 EXISTING SEWER STANDPIPE
» »» EXISTING DRAINFIELD
$ WATER KEY BOX
98.6 SPOT ELEVATION
♦
00
0o
00
00
°0
00
00
00
10
0o `
00
TB. i ELEV. 100.00 \
B ETON OF SIDING
�6. 4 1
'o PROPOSED FINAL CONTOURS 1
o
- t�
1 '
25 0 25 50 75 100 125 150
SCALE. 1' = 50 FT.
ITOBBEN SPURKLAND P.E. LOT 9 BLOCK 2 CREEN1ROOli SEPTIC SYSTEM DESIGN
203 W 15TH. AVENUE 12700 Von Seheben DATE: July 31, 1994
ANCH. AK. 99501 Erieko Kromer I I SHEET: 2/4 GRID: 2839
From ,
r
3/4' Washed Rock
SIDE VIEW
6" Hol/pipe
PVC, Holes Pointing Vp
bW�
Lateral and Orfi/ice Shield
TOBBEN SPURKLAND P.E. 111x20 SAND FILTER SEPTIC SYSTEM DESIGN
203 W 15TH. AVENUE LOT 9 BLOCK 2 ORMVGR00K DATE: JULY 30, 1994
ANCH. AK. 99501 11 fRICKA KRAMfR 11 SHEET: 314 GRID: 2839
f
I30.00 /I 1
I o J■-
DRAINFIELD
5 FT WIDE
30 FT LONG
1 FT OF ROCK
1 FT TOTAL DEPTH
3 FT OF COVER
1500 GAL STEP TANK
WIM 2 -INCHES OF INSULATION
Sample Access.
8 -Inch Sump
.--T-
5.00 lI I
8" Sump
8' Tee
4- To Rele4' From filler
e
SAMPLING PORT
NO SCALE
3' Cow
/— 4" Topsoil
0V OVOVOVOVOV
12" Sewer Rock —
4" Distribution Pipe
Miroli 140 -
71JO194
2 FT. MIN J
1500 Go/ STEP J
BENCH MARK:
BOTTOM SIDING
ASSUMED ELEV. 100.00 FT
TOBBEN SPURKLAND P.E. LOT 9 BLOCK 2 GREENTROOK(I SEPTIC SYSTEM DESIGN I
203 W151h Ave 12700 VON SCHASEN DATE: ULY 17, 1994
Anchorage Ak 99501 FRICKA KRAMER SHEET. 4VII GRID: 2637
to
G
U-5 c"o 0
0
ca
ca C3ca
z -0-0
Ll
>
CL Po
\)R
a:
w
>
0.
Z'I.
LU
—:3
Cl)
\\
Lu
q
.
of
IM
\\
2
E
C)
14
r
z
A"
tnEn
M
cc
en o
Enz
n 5.0
cc
ca(tix �U— cz :3
UL] O
xny
cl LC
\ ) Ix
LLI
![ƒ
�[ (
> tu V'.
O -j
<
.91
0
(n
—
L) :1tnz
cc
rg�[=Ui=
�i :3
C:3
OW
u
0 CC LL
�
cc C3.'-'
a t: z z
LU A IV
cc�'
Lu
to
9
Lij
CD
cc
En
LU
Lk
uj
5; m
LL,
§b2
Vi cn
P F-
cn
b
cu
x
bi
K -
N
a:
w
0.
Z'I.
9
Lij
CD
cc
En
LU
Lk
uj
5; m
LL,
§b2
Vi cn
P F-
cn
b
cu
x
bi
K -
N
oiuncc slum
1/Y ou. scit eo ry rout. tirnt
{/ DIA. DWIiCL"S
OjG ACCO
0/4* DIA. CLx 3 200 PVC UANIfOLD
i Dt..Clue 150 olott#4 PVC pipe
(Cut 1/4' Vida $lots 2-1/Y deep
.nd. of c' O C.) _� _ _
Illll IIIIIII1111111111 111111111111111111111111111111111111111111111
—410IA. rvc c r
1TItA1fS('OR7 LINE ''00 PVC`
11/4 die, Class . \
'—TIU.11jtT10N to t'
air difuvice
1' or 1 -1/4 -DIA. PVC HOOT
The boot flange li bonded to 0� 0�0 rte`
lincA
N
0'
a
50mit rye Unca—i
at oath corner clean—out
O
11111IIIIII 1141111111111111�1IIII 1111111111
CL 200 rye
INC UNC --
eDIA. FLUSIII14C VALVE x/8 -PVC
acccss riser and fiberglass cover
\—Z- SLOTTED PVC PIPE (cut 1/4
2' i11SULATION AROUtiO wide slots 4 O.C.-orlon! slots
PERIMETER OF FILTER down to dcofn)
K p!5M)8L) hWJ /flR W/Ul�
r✓ >'qjj r o!/(z-o(osF� 0A) �V.
.TUL.—'1Z-9A
WED
10:09
DHHS
P.05
oiuncc slum
1/Y ou. scit eo ry rout. tirnt
{/ DIA. DWIiCL"S
OjG ACCO
0/4* DIA. CLx 3 200 PVC UANIfOLD
i Dt..Clue 150 olott#4 PVC pipe
(Cut 1/4' Vida $lots 2-1/Y deep
.nd. of c' O C.) _� _ _
Illll IIIIIII1111111111 111111111111111111111111111111111111111111111
—410IA. rvc c r
1TItA1fS('OR7 LINE ''00 PVC`
11/4 die, Class . \
'—TIU.11jtT10N to t'
air difuvice
1' or 1 -1/4 -DIA. PVC HOOT
The boot flange li bonded to 0� 0�0 rte`
lincA
N
0'
a
50mit rye Unca—i
at oath corner clean—out
O
11111IIIIII 1141111111111111�1IIII 1111111111
CL 200 rye
INC UNC --
eDIA. FLUSIII14C VALVE x/8 -PVC
acccss riser and fiberglass cover
\—Z- SLOTTED PVC PIPE (cut 1/4
2' i11SULATION AROUtiO wide slots 4 O.C.-orlon! slots
PERIMETER OF FILTER down to dcofn)
K p!5M)8L) hWJ /flR W/Ul�
r✓ >'qjj r o!/(z-o(osF� 0A) �V.
PROPERTY OWNER AGREEMENT
INTERMITTENT SAND FILTER WASTEWATER DISPOSAL SYSTEM
This agreement, dated 8, l .CJA4 , 1994, is made between the Municipality
of Anchorage Department of Health and Human Services (DHHS) and the property
owner(s) of DI' TYYt(1�1_`� ����� k�?CY7✓
This agreement is made for the purpose of designing, constructing and testing an
intermittent sand filter on-site wastewater disposal system on the subject property.
The property owner(s) agree to the following:
1. The property owner(s) will allow DHHS and its representatives access to the
subject property as required during the design, construction and testing of
the wastewater system.
2. The property owner(s) agree to bear all costs involved in a testing program
which will sample the effluent from this wastewater system for a period of
one year. Th's testi g program will involve the engineer on this project,
j'op���/_, sampling the effluent every other month for 12
months for: total suspended solids, BOD5, fecal coliform, nitrates, and total
kjeldahl nitrogen. Also determined on the same sampling schedule will be
the septic tank effluent temperature and the sand filter effluent temperature.
The property owners will pay all engineering and laboratory costs involved.
All data will be furnished to DHHS in a timely manner.
,l�Yit
L,Prop rty Owner Name Property/owner Name
(Notarize Here)
t e ��st, q .- .
1
Municipality of Anchorage
1 Development Services Department
j Building Safety Division °
On -Site Water & Wastewater Program
4700 Bragaw Street
P.O. Box 196650
Anchorage, AK 99519-6650
www.muni.org/onsite T
(907)343-7904
CERTIFICATE OF ON-SITE SYSTEMS APPROVAL
FOR A SINGLE FAMILY DWELLING /�]
Parcel I.D. 017-431-17 COSA# Q % C' 3 LF
1. GENERAL INFORMATION Expiration Date: I I — 7 — / 0
Complete legal description
Location (site address)
Current Property owner(s)
Mailing address
Lending agency
Mailing address
Real Estate Agent
Mailing address
GREENBROOK S/D; BLOCK 2. LOT 9
12700 VON SCHEBEN DRIVE • ANCHORAGE. AK * 99516
BAXTER BURTON Day phone 644-3966
12700 VON SCHEBEN DRIVE • ANCHORAGE. AK • 99516
Day phone
BOB BAER W/ DYNAMIC PROPERTIES Day phone 261-7506
110 W. 38TH AVE, N100 • ANCHORAGE, AK 4 99503
Unless otherwise requested, COSA will be held by DSD for pickup.
2. NUMBER OF BEDROOMS: 4
3. TYPE OF WATER SUPPLY:
Individual Well
❑
Individual Water Storage
❑
Community Class A Well
❑
Public Water System
❑
TYPE OF WASTEWATER DISPOSAL:
Individual On-site
N
Individual Holding tank
❑
Community On-site
❑
Public Sewer
❑
The Municipality of Anchorage Development Services Department (DSD) Issues Certificates of On -Site Systems
Approval (COSA) based only upon the representations given in paragraph 4 by an Independent professional civil
engineer registered in the State of Alaska. Certificates of On -Site Systems Approval are required for the transfer
of title (except between spouses) for properties served by a single-family on-site wastewater disposal and/or
water supply system. DSD also Issues COSAs upon request to homeowners. Certificates of On -Site Systems
Approval are valid for 90 days from the date of issue for properties served by a private or Class C well and may
be reissued with new water samples. (Certificates may be reissued for a period of up to one year with valid water
samples.) Certificates are valid for one year for properties served by Class A or B wells or a public water system.
The Municipality of Anchorage is not responsible for errors or omissions in the professional engineers work.
4. STATEMENT OF INSPECTION BY ENGINEER
As certified by my seal affixed hereto and as of the validation date shown below, I verify that my
investigation, based on procedures outlined in the Certificate of On -Site Systems Approval Guidelines for this application,
shows that the on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate
for the number of bedrooms and type of structure indicated herein. I further verify that based on the
information obtained from the Municipality of Anchorage riles and from my investigation and Inspection, the
on-site water supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal
and State codes, ordinances, and regulations in effect at the time of installation.
Name of Finn GARNESS ENGINEERING GROUP, Ltd. Phone
Address 3701 E. TUDOR ROAD, SURE 101 " ANCHORAGE, AK 99507
Engineers Printed Name JEFFREY A. GARNESS, P.E.
Engineers Comments:
In conducting this evaluation, GEG, LtD. attempted to provide a thorough,
conscientious engineering analysis of the system in accordance with ADEC and MOA
DSD Guidelines B Regulations. The reported results described the performance of the
system under the conditions encountered at the time of the test, and separation
distances measured to readily identifiable features. The operational life of all wells and
septic systems depend on the local soils condition, groundwater levels that may
fluctuate during the year, and the water usage of the family being served by the system.
These conditions are outside the control of the evaluator of the system. Satisfactory test
results do not guarantee future performance ofthe system, nor do they guarantee that
there are no hidden defects or encroachments. GEG, LTD. can therefore not provide
any warranty or future estimate of how long the system will continue to meet the
operational requirements of the ADEC or MOA DSD. The content of this report is for
the solo benefit of the owner listed above. Any reliance upon or use of this report by any
other person or party Is not authorized, nor will it confer any legal right whatsoever.
5. DSD SIGNATURE
Approved for --Y— bedrooms.
Disapproved.
337-6179
Date t o Z lb
Conditional approval for bedrooms, with the fllowing stipulations:
Attachments:
COSA Checklist
Septic System Advisory
Well Flow Advisory
Nitrate Advisory
Arsenic Advisory
Maintenance Agreements
Supplemental Engineers Report
Other
oy OFq ,
ON-SITE
WATERAND ; M=
WASTEWATER
PROGRAM c
. is ••.._..•'.c4o`.i\�
'hi
By hl Q Original Certificate Date: 1 I 1
(Rw. 11105)
-� 'Municipality of Anchorage
( Development Services Department
,
Building Safety Division
On -Site Water & Wastewater Program
:
4700 Bragaw Street
P.O. Box 196650
Anchorage, AK 99519.6650
www.muni.org/onsite
(907)343-7904
CERTIFICATE OF ON-SITE SYSTEMS APPROVAL CHECKLIST
Legal Description: GREENBROOK S/D• BLOCK 2 LOT 9
Parcel ID: Ii/7- q 3 1 -/ 7
A. WELL DATA
Well type CLASS "A"
If A. B, or C provide PWSID# 210346 Well Log
Date completed Sanitary seal /N
Total depth ft.
Date of test
Static water level
Cased to ft.
FROM WELL LOG
Well production
WATER SAMPLE RES
Coliform colonies/100 ml.
enic: ug./L.
B. SEPTIC/HOLDING TANK DATA
Wires properly protected
Casingheight (ab rc
ATI CTION
ft.
in.
g.p.m.
9 -P.M.
Nitrate mg./L. Other bacteria
colonies/100 ml.
Date of sample: Collected by:
Tank Type/Material _ S.T.E.P./STEEL
Date installed 6/21-24/2007
Tank size 1500 gal. Number of Compartments?
Cieanouts (Y/N) YES
Foundation cleanout (Y/N) YES Depression over tank (YIN) NO High water alarm (Y/N) YES
Date of pumping _ 3/2_0/2009_ pumper A+ HOME SERVICES
C. ABSORPTION FIELD DATA
9/30/1994 E W %ISTING GRADE
Date installed -9ZZ7-24/2007 Soil rating p.d./ r ft%drm 4 4 LINED ISF/
) System type DUAL TRENCH
Length _30/30 ft. Width_ 5/5
+3.5/ -- --ft Gravel below pipe 0.5 0.5 ft.
Total depth !�ft. Eff. absorption area 300 ft' Monitoring tube YES Depression over field NO
Date of adequacy test "`t%2009 20/Results (Pass/Fail) PASS
For 4 bedrooms
Fluid depth in absorption field before test 0 In. Water added 615
gal. New depth 0 in.
Elapsed Time: min. Final fluid depth 0 in.
Absorption rate >= 600+
Any rejuvenation treatment (past 12 mo.) (Y/N &g p d
type) NONE KNOWN If yes, give date
"TESTED 2007 TRENCH ONLY. 1994 TRENCH WAS FULL.
D. LIFT STATION
Date installed —8z2 1 --24 2007 Size in gallons 1�—
"Pump on" level at TIMER in.
Datum BOTTOM OF TANK
off" level atTIMER in.
Manhole/Access (YIN) YES
High water alarm level at_ .461n.
Pump YES
Cycles tested
3 Meets alarm & circuit requirements?
E. SEPARATION DISTANCES
SEPARATION DISTANCES FROM WELL ON LOT TO:
Septic tank/lift station on lot �—
Absorp:ion field on lot
Public sewer main
COMMUNITY WELL
On adjacent
On adjacent lots
manhole/cleanout
Sewer (septic service line
Holding tank
ontainment areas— Manurelanimal excrete storage areas ;_----
SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK ON LOT TO: g'+
Absorption field
Building foundation 5+— Property liner
10'+ Surface water 100'+
Water main 10'+ Water service line—
Wells on adjacent lots 200'+
SEPARATION DISTANCE FROM ABSORPTION FIELD ON LOT TO: 10'+/10'+
Property line t o� Building foundation 10'+ t o'+ Water main
Water service line 101+ 1 o'+ Surface water 100 0 ± Driveway, parking/vehicle storage
Curtain drain NONE N Wells on adjacent lots 200'+�00 +
F. COMMENTS
G. E
Se Waiver Fee $
COSA Fee A � ��O
Date of Payment
Date of Payment
1 u Receipt Number
Receipt Number
(Rev. 11/05)
10/19/2009 14:43
8686770
APLUS
A+ HOME SERVICES, INC.
7501 E. 140th Avenue
Anchorage, Alaska 99516
345-1890
CUSTOMER
Lot
WW
INVOICE # 35987
DATE
DESCRIPTION
AMOUNT
I.sp—# qeptic luk
$55.00
TOTAL
REkARKS
i.
ry
Gallons Septic
Leach Area Holding Tank
—Standpipes Time
❑
PROBLEM AREA—CALL
FOR MORE INFORMATION
❑
NEEDSTO BE DONE AGAIN IN 6 MONTHS
❑
Good Shape
❑ sludge buildup on bottom
❑ Floater on top
❑
Jim cap missing or
❑ Cut standpipe to 1' above ground
❑ Needs Septictrine
needs replacing
10/19/2009 14:43 8686770 APLUS PAGE 02
At HOME SERVICES, INC.
CUSTOMER
Block
7501 E. 140th Avenue
Anchorage, Alaska 99516
345-1890
12700 VonScheben Drive
AnKiMorage,7M M16
Lot
INVOICE# 35986
DATE
DESCRIPTION
AMOUNT
320-cP[
Nmv sgzic & Lift
$150.
DO
�
A itself
R er-7*tke,%0 bfback to inspect in ao days after tank has refill
Tank locgteA- I' bQX, ON NW '. S I DIF PE! KOL66
TOTA L
O
eo
i.1REAAKS
5rA-n0AA
rvtt- I VV7TT�Nje >=59
15_4allonS Septic Leach Area Holding Tank
2- Standpipes
— Time
❑ PROBLEM AREA —CALL FOR MORE INFORMATION
El NEEDSTO BE DONE AGAIN IN 6 MONTHS
C1 Good Shape 0 sludge buildup on bottom
11 Floater on top
0 Jim cap missing or 0 Cut standpipe to Vabove ground
0 Needs Septictrine
needs replacing
ADVANCED WASTEWATER TREATMENT SYSTEM MAINTENANCE AND
REPAIR AGREEMENT
MEMORANDUM OF UNDERSTANDING
BETWEEN MUNICIPALITY OF ANCHORAGE
AND NPknr� (tri.uc, I
THIS MEMORANDUM OF UNDERSTANDING made and entered into as of this
:L(O— Day of O t_ 4 oh e l of 200, by and between tJ t< 0 • & I" a(
herein the "OWNER," and the Municipality of Anchorage, herein the
"MUNICIPALITY." In consideration of the mutual covenants contained herein, the
parties to this Memorandum of Understanding agree as follows:
1. ADVANCED WASTEWATER TREATMENT SYSTEMS. Municipality
grants permission to Owner to utilize and operate an Advanced Wastewater
Treatment System (AWWTS), described as T ? f s located
//''
at I T re en bu o% ADL L t p, , Anchorage, Alaska.
2. Definitions.
A. Alteration. Any change to the design or function of an AWWTS that
Includes the installation or removal of any parts, components or pieces not
included in the original construction permit and design. Prior to
performing any alterations to an AWWTS the owner must obtain a
Wastewater Disposal System Construction Permit from the Municipality
pursuant to Anchorage Municipal Code (hereinafter, "AMC") 15.65.
B. Certificate of On -Site Systems Approval. An approval by the
Municipality of existing water and wastewater disposal systems given at
the time of property sale and title transfer in accordance with AMC 15.65.
These approvals certify that the systems are adequate for the homes that
they support and meet the codes that were in place at the time of system
construction.
C. Damage. Any man-made or natural change in a system that would inhibit
the system from performing as designed.
D. Maintenance and Repair. The scheduled and as needed replacement of
existing parts, components and pieces of an AWWTS that were included in
the original design which would allow the AWWTS to continue to
perform as designed.
E. Permit (Construction) An On -Site Wastewater Disposal System
Construction Permit as defined by AMC 15.65.
F. Permit (Operating) An Advanced Wastewater Treatment System
Operating Permit. An annual permit, issued by the Municipality, that
allows the Owner to operate an AWWTS, upon meeting all the
requirements of this agreement, the conditions of Operating Permit, the
requirements of the On -Site Wastewater System Construction Permit and
all relevant provisions of AMC 15.65
3. Fee. Owner shall pay to Municipality an annual fee of O
(S -a.00), .00), payable on or before the issuance of the operating permit and annually
thereafter. The annual fee is due on or before the anniversary date of the approval by the
Municipality of installed system.
4. Term. The term of this Memorandum of Understanding shall be for the life of the
AWWTS.
The term begins on the date of approval by the Municipality of the installed system and
shall continue while the AWWTS system is in use or operational or until the property is
sold or title is transferred by owner and a new certificate of On -Site approval is issued to
the new owner or transferee of the property.
5. Alterations, installation and Removal of Additional Equipment. Owner agrees
not to make any alterations, removal of parts or additions to the AWWTS without a
Construction Permit from the Municipality.
6. Maintenance and Repairs.
A. Throughout the term of this Memorandum of Understanding, the Owner shall
maintain AWWTS in good repair. In addition, it shall be the responsibility of the
Owner during the term of this Memorandum of Understanding, and any extensions or
renewals thereof, at the owner's sole expense, to pay for any and all: (1) repair(s), (2)
maintenance, (3) adjustment(s), (4) replacement costs, and (5) inspection costs.
Further, Owner agrees to comply will all applicable ordinance, laws, regulations,
rules and orders for the AWWTS.
B. Owner agrees to provide the Municipality a written schedule of routine
maintenance and repairs which have been performed on the system pursuant to the
terms and conditions contained in the Owner's AWWTS Operating Permit. This
schedule shall be submitted to the Municipality annually upon the renewal of the
permit. The schedule of maintenance and repair contained in the Owner's AWWTS
Operating Permit is: _1 u-j_i (d /q Ll eccx
C. Owner acknowledges that the fine schedule for failing to maintain and repair an
AWW IFS are codified in AMC 14.60.
\T
D. Owner agrees that only maintenance, repair personnel certified by the
Municipality will inspect and make any necessary maintenance, repairs or permitted
alterations to the system.
E. Owner agrees to grant the Municipality reasonable access to test and inspect the
AWWTS upon 24 hours written notice.
F. Owner agrees that any sale or transfer of title of the property will not occur
without a new Certificate of On -Site Systems Approval.
G. Owner agrees that the relevant provisions of the standard specification guidebook
for AWWTS is the governing professional guidelines for the construction,
maintenance and repair of the Owner's AWWTS.
7. Nonwaiver. The failure of either party at any time to enforce a provision of this
Memorandum of Understanding shall in no way constitute a waiver of the provisions,
nor in any way ¢ffect the validity of the Memorandum of Understanding or any part
hereof, or the right of such parry thereafter to enforce each and every provision
hereof.
8. Amendment.
A. This Memorandum of Understanding shall only be amended, modified or changed
by a writing, executed by authorized representatives of the parties, with the same
formality of this Memorandum of Understanding was executed and such writing shall
be attached to this Memorandum of Understanding as an amendment.
B. For the purposes of any amendment modification or change to the terms and
conditions of this contract, the only authorized representatives of the parties are: `, �Ttq
),,----,—Owner:
Anchorage: Purchasing Officer
C. Any attempt to amend, modify, or change this contract by either an
unauthorized representative or unauthorized means shall be void.
9. Jurisdiction: Choice of Law. Any civil action arising from this Memorandum of
Understanding shall be brought in the Superior Court for the Third Judicial District of the
State of Alaska at Anchorage. The laws of the State of Alaska shall govern the rights and
obligations of the parties under this Memorandum of Understanding.
10. Severability. Any provisions of this Memorandum of Understanding decreed
invalid by a court of competent jurisdiction shall not invalidate the remaining provisions
of the Memorandum of Understanding.
OWNF.�
Y:
Date:
Date: t-Od
STATE OF ALASKA
THIRD JUDICIAL DISTRICT
MUNICIPALITY:
By:
Title:
Date:
) ss.
The foregoing instrument was acknowledged before me this Oday of ,f/nrr, ,her ,
20_6, by `jelsoi, /l Pri d�
r=
C(KML1C
NO BLIC FOR ALASKA M mmissionexpires: Nov Z zv/1
municipality of Anchorage
Development Services Department
Building Safety Division
On -Site Water & Wastewater Prol
4700 Bragaw Street
P.O. Box 196650
Anchorage, AK 99519.6650
www.muni.org/onsite
(907) 343-7904
0`
CERTIFICATE OF ON—SITE SYSTEMS APPROVAL
FOR A SINGLE FAMILY DWELLING
Parcel I.D. (�1'� -L431- l COSAff 00359
1. GENERAL INFORMATION
Expiration Date:
Complete legal description GREENBROOK SUBDIVISION, LOT 9 BLOCK2
Location (site address) 012700 VAN SCHEBEN DRIVE • ANCHORAGE AK
Current Property owner(s)
THOMAS KRAMER Day phone 250-0090
Mailing address 2551 LOUSSAC DRIVE • ANCHORAGE AK 99517
Day phone
Lending agency
Mailing address
CLAIR RAMSEY w/DYNAMIC PROPERTIES Day phone 261-7554
Real Estate Agent
Mailing address 3111 C STREET SURE 100 •ANCHORAGE AK 99503
Unless otherwise requested, COSA will be held by DSD for pickup.
2. NUMBER OF BEDROOMS: 4
The Municipality of Anchorage Development Services Department (DSD) Issues Certificates of On -Site Systems
Approval (COSA) based only upon the representations given in paragraph 4 by an independent professional civil
engineer registered in the State of Alaska. Certificates of On -Site Systems Approval are required for the transfer
of title (except between spouses) for properties served by a single-family on-site wastewater disposal and/or
water supply system. DSD also issues COSAs upon request to homeowners. Certificates of On -Site Systems
Approval are valid for 90 days from the date of Issue for properties served by a private or Class C well and may
be reissued with new water samples. (Certificates may be reissued for a period of up to one year with valid water
samples.) Certificates are valid for one year for properties served by Class A or B wells or a public water system.
The Municipality of Anchorage is not responsible for errors or omissions in the professional engineers work.
TYPE OF WASTEWATER DISPOSAL:
3. TYPE OF WATER SUPPLY:
Individual Well
❑
Individual On-site
N
Individual Water Storage
❑
Individual Holding tank
O
Community Class A Well
N
Community On-site
❑
Public Water System
❑
Public Sewer
.
The Municipality of Anchorage Development Services Department (DSD) Issues Certificates of On -Site Systems
Approval (COSA) based only upon the representations given in paragraph 4 by an independent professional civil
engineer registered in the State of Alaska. Certificates of On -Site Systems Approval are required for the transfer
of title (except between spouses) for properties served by a single-family on-site wastewater disposal and/or
water supply system. DSD also issues COSAs upon request to homeowners. Certificates of On -Site Systems
Approval are valid for 90 days from the date of Issue for properties served by a private or Class C well and may
be reissued with new water samples. (Certificates may be reissued for a period of up to one year with valid water
samples.) Certificates are valid for one year for properties served by Class A or B wells or a public water system.
The Municipality of Anchorage is not responsible for errors or omissions in the professional engineers work.
4. STATEMENT OF INSPECTION BY ENGINEER
As certified by my seal axed hereto and as of the validation date shown below, I verify that my
investigation, based on procedures outlined in the Certificale of On -Site Systems Approval Guidelines for this application,
shows that the on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate
for the number of bedrooms and type of structure indicated herein. I further verify that based on the
Information obtained from the Municipality of Anchorage riles and from my investigation and inspection, the
on-site water supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal
and State codes, ordinances, and regulations in effect at the time of installation.
Name of Firm GARNESS ENGINEERING GROUP, Ltd. Phone 337-6179
Address 3701 E. TUDOR ROAD, SURE 101 * ANCHORAGE, AK 99507
Engineer's Printed Name JEFFREY A. GARNESS, P.E. Date
Engineers Comments:
In conducting this evaluation, GEG, LtO. attempted to provide a thorough,
conscientious engineering analysis of the system In accordance with ADEC and MOA
DSD Guidelines & Regulations. The reported results described the performance of the
system under tho conditions encountered at the Gime of the test, and separation
distances measured to readilyldentifiable features. The operational life of all wells and
septic systems depend on the local soils condition, groundwater levels that may
fluctuate during the year, and the water usage of the family being served by the system.
These conditions are outside the control of the evaluator of the system. Satisfactory test
results do not guarantee future performance of the system, nor do they guarantee that
there are no hidden defects or encroachments. GEG, LTD. can therefore not provide
any warranty or future estimate of how long the system will continue to meet the
operational requirements of the ADEC or MOA DSD. The content of this report is for
the sole benefit of the ownerlisted above. Anyreliance upon oruso of this report by any
other person or party Is not authorized, nor will It confer any legal right whatsoever.
5. DSD SIGNATURE
f/ Approved for _q bedrooms.
Disapproved.
Conditional approval for bedrooms, with the fllowing stipulations:
Attachments:
COSA Checklist (/
Septic System Advisory
Well Flow Advisory
Nitrate Advisory
Arsenic Advisory
Maintenance Agreements
Supplemental Engineers Reort
Other
By: Original Certificate Date:_
(Rm. 11005)
• C
WA
WAS
PR
• • Q
V -SITE
'ER AND
TWATER
)GRAM
�.
J
13
y A. Go ess:'
'
a,.
CE -779 .��
Conditional approval for bedrooms, with the fllowing stipulations:
Attachments:
COSA Checklist (/
Septic System Advisory
Well Flow Advisory
Nitrate Advisory
Arsenic Advisory
Maintenance Agreements
Supplemental Engineers Reort
Other
By: Original Certificate Date:_
(Rm. 11005)
• C
WA
WAS
PR
• • Q
V -SITE
'ER AND
TWATER
)GRAM
Municipality of Anchorage
Development Services Department
Building Safety Division
On -Site Water & Wastewater Program
4700 Bregaw Street
P.O. Box 196850
Anchorage, AK 99519.6650
www.muni.org/onaite
(907) 343-7904
CERTIFICATE OF ON-SITE SYSTEMS APPROVAL CHECKLIST
Parcel ID: O 17- 4 3 / /
Legal Description: GREENBROOK SUBIDMSION IAT 9 BLOCK 2
A. WELL DATA COMMUNITY WATER
Well type H A, B, or C provide PWS1O# k 103 H % wen Log (Y/N)
Date completed
Sanitary seal (Y/N)_ Wires properly protected (Y
Total depth ft. Cased to
ft. Casing height a ground) in.
FROM WELL LOG
Data of test
Static water level
Well production g'P'm'
WATER SAMPLE S:
rWie,m, _ colonies/100 ml. Nitrate mg./L.
ft.
9—
p.m-o
ther bacteria colonies/100 ml.
nic: ug./L.
Date of sample: Collected by:
B. SEPTICIHOLDING TANK DATA g/21 _24/2007
STEP./STEEL Data installed
Tank Type/Material YES
Tank size 1500 gat. Number of Compartments E Cleanouts (Y/N)
Foundation deanOut (YIN) YES Depression over tank (YIN) NO High water alarm (YIN) YES
Date of pumping �— Pumper
C. ABSORPTION FIELD DATA 8MMEffiNZ=
Spyy TRENCH
9/30/1994/ 4 4 System type
Date installed 8/21/2007 Soil rating .p.d ft /bdnn)-L
5/5 ft. Gravel below pipe __15/0-5 ft.
Length30_ /_ 30 ft. Width 150/
ft. Eft. absorption area 150 fe Monitoring tube YES Depression over field NO
Total depth*AA � 41
Date of adequacy test
NEW Results (PasslFail) PASS For 4 bedrooms
Fluid depth in absorption field before test = in. Water added =gal. New depth =in.
Elapsed Tune: = min, Final fluid depth
In. Absorption rate >= 600+ g.p.d.
Any rejuvenation treatment (past 12 mo.) (Y/N & type) NONE KNOWN If yes, give date –
D. UFT STATION
Date insWiled8/21-24/2007 Size in gallons 1500 Manhole/Access (Y/N) YES
"Pump on" level at TIMER in. "Pump ofP level at TIMER in. High water alar level at 48 in.
Datum BOTTOM OF TANK Cycles tested NEW Meets alar 8 circuit
requirements? YES
E. SEPARATION DISTANCES
SEPARATION DISTANCES FROM WELL ON LOT TO: COMMUNITY
AVvNITY VATER
Septic tank/lift station on lot On adjacent
Absorption field on lot On adjacent
Public sewer main
Sewer /septic service
areas
sewer manhole/cleanout
Holding tank
Manure/animal excrete storage areas
SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK ON LOT TO:
Building foundation 5'+ Property line 5'+ Absorption field 5'+
Water main 10'+ Water service line 10'+ Surface water 100'+
Wells on adjacent lots 200'+
SEPARATION DISTANCE FROM ABSORPTION FIELD ON LOT TO:
Property line
10'+
Building foundation
10'+
Water main 10'+
Water service line
10'+
Surface water
100'+
Driveway, parking/vehicle storage 10'+
Curtain drain NONE KNOWN Wells on adjacent lots 200'+
F. COMMENTS
G. ENGINEER'S CERTIFICATION Of
I cerW that I have determined through held inspections and
review of Municipal records that the above systems are in """"' ' ..• • • • • • • • • • •
conformance with MOA COSA guidelines in effect on this
date. .. .. ............
•.Je A. aes�
Engineer's Printed Name JEFFREY A GARNESS y7
A.
Data rj/S�b� �,r
COSA Fee S `Z 30 c,o 4 176 g us N Waiver Fee $ _
Date of Payment 2.1,S/ U 7 Date of Payment
Receipt Number 7 9 Receipt Number
(Rev. 1 IM)