Loading...
HomeMy WebLinkAboutSCIMITAR #1 S-11537-1Scimitar #1 5-11537-1 Municipality of Anchorage *A. Development Services Department, Building Safety Division ° MEMORANDUM DATE: October 2, 2006 TO: Jerry Weaver, Jr., Platting Officer, CPD FROM -0 / aniel Roth, Program Manager, On -Site Water and Wastewater Program SUBJECT: Comments on Cases due October 12, 2006 The On -Site Water & Wastewater Program has reviewed the following cases and has these comments: S11536-1 Meyers Subdivision Information to satisfy the requirements specified by AMC 21.15, AMC 15.55 and AMC 15.65 must be submitted for each lot within this proposed subdivision. This information must include, but may not necessarily be limited to: 1. Soils testing, percolation testing, and ground water monitoring must be conducted to confirm the suitability for development using on-site wastewater disposal systems. Ground water monitoring must be conducted during high ground water season in either the fall (October) or spring (May). 2. Areas designated for the original and replacement wastewater disposal system sites must be identified and must meet all criteria specified in AMC 15.65 including slope and slope setback requirements for each lot. 3. Topographical information must be submitted. 4. Provide documentation for water availability to serve water wells. 5. The inspection report for the newly constructed wastewater system serving the existing home in the proposed subdivision has not been submitted to this office. This must be done prior to final plat sign off. 6. A well log and pump log for the existing water well has not been submitted to this office. This must be done prior to final plat sign off. amtar 4I3u rv�sron Information to satisfy the requirements specified by AMC 21.15, AMC 15.55 and AMC 15.65 must be submitted for each lot within this proposed subdivision. This information must include, but may not necessarily be limited to: Comments on Cases due 10/2/2006 Page 2 1. Soils testing, percolation testing, and ground water monitoring must be conducted to confirm the suitability for development using on-site wastewater disposal systems. Ground water monitoring must be conducted during high ground water season in either the fall (October) or spring (May). 2. Areas designated for the original and replacement wastewater disposal system sites must be identified and must meet all criteria specified in AMC 15.65 including slope and slope setback requirements for each lot. 3. Topographical information must be submitted. 4. Provide documentation for water availability to serve water wells. 5. An undocumented wastewater system exists in the proposed subdivision that serves the existing home. An undocumented water well serves the home also. These items must be documented and as -built documents provided to this office prior to final plat sign off. S11538-1 Mabel liopp Subdivision Show potential water well sites for each of the proposed 7 lots that will meet the requirements of Anchorage Municipal Code 15.55. Please fill in the information asked for below. PROPERTY INFORMATION PETITIONER REPRESENTATIVE (IF ANY) PETITIONER Name (last name ust) Name (last name rst) SB'Lvf1/ ;i j Mailing Address o f�o�( 676 -7Gz Mailing Address os a9 45yV0_i9 9�G7 /o- na 9vr» n Contact Phone: Day: GO _Z 6 Night Contact Phone: Day. O Z9 Night FAX: FAX: " „ 13g3d E -trait: E-mail: PROPERTY INFORMATION Property Tax #(00000aoo-0oo): Site Street Address: Z 6 Current legal description: (use additional sheet It necessary) - scimir�.c✓ zoning: Acreage: ,00 Grid # # Lots: / # Tracts: 6 Total #parcels: / 1 hereby certify that (I am)(I have been authorized to act for) owner of the property described above and that I petition to subdivide it in conformance with Title 21 of the Anchorage Municipal, Code of Ordinances. I understand that payment of the application fee is noncefundable and is to cover the costs associated with processing this application, and that it does not assure appraval of the subdivision. I also understand that assigned hearing dates are tentative and may have to be postponed by Planning Department staff or the Platting Board, Planning and Zoning Commission, or the Assembly for administrativ�ereasons. ` Z / I /// s (Agents must provide written proof of authorization) PROPOSED SUBDIVISION INFORMATION Proposed legal description: (use additional sheer In necessary) # Lots: S.115 3 7. Uct 1 6 2M it by: `..rl Po W&'AlridaMt -"',�' '"'""� Fee _ ..•� Case Number''7'-""" Application for Preliminary Plat continued Page 2 COMPREHENSIVE PLAN INFORMATION Anchorage 2020 Urban/Rural Services: ❑ Urban ❑ Rural Anchorage 2020 West Anchorage Planning Area: ❑ Inside ❑ Outside Anchorage 2020 Major Urban Elements: Site is within or abuts: O Major Employment Center ❑ Redevelopment/Mixed Use Area ❑ Town Center ❑ Neighborhood Commercial Center ❑ Industrial Center ❑ Transit - Supportive Development Corridor [p Site topography (4 copies minimum) Eagle River-Chugiak-Peters Creek Land Use Classification: ❑ Commercial ❑ Industrial ❑ Parks/opens space ❑ Public Land Institutions ❑ Marginal land ❑ Alpine/Slope Affected ❑ Special Study ❑ Residential at dwelling units per acre Girdwood- Tumagain Arm ❑ Commercial ❑ Industrial ❑ Parks/opens space ❑ Public Land Institutions ❑ Marginal land ❑ Alpine/Slope Affected ❑ Special Study ❑ Residential at dwelling units per acre ENVIRONMENTAL INFORMATION (" portion of see affected) Wetland Classification: ❑ None ❑ "C" ❑ "B" ❑ "A" Avalanche Zone: ❑ None ❑ Blue Zone ❑ Red Zone Floodplain: ❑ None ❑ 100 year ❑ 500 year Seismic Zone (Harding/Lawson): ❑ "1" ❑ 02" ❑ "3" ❑ "4" ❑ "5" RECENT REGULATORY INFORMATION (Events mat have occurred in last 5 years for all or portion of see) ❑ Rezoning - Case Number: ❑ Preliminary Plat ❑ Final Plat -Case Number(s): ❑ Conditional Use - Case Number(s): ❑ Zoning variance - Case Number(s): ❑ Land Use Enforcement Action for ❑ Building or Land Use Permit for ❑ Wetlandpermit: ❑ Army Co of Engineers ❑ Municipality of Anchorage POTABLE WATER AND WASTE WATER DISPOSAL Potable Water provide by: ❑ Public utility ❑ Community well ❑ Private well Wastewater disposal method: ❑ Public utility ❑ Community system ❑ Private on-site APPLICATION CHECKLIST Fee: Plat: Copies tits) 11132 (short plats only) copy Other maps 53 Aerial photo ❑ Housing stock 0 Zoning Mandatory on plat depictions: ❑Pedestrian-waKwa 11"ndseaping required by zoning Property Title: ❑ Certificate to Plat Additional required documents unless specifically waived by Platting Officer: [p Site topography (4 copies minimum) Waived by ❑ Soils investigation and analysis reports (4 copies minimum) Waived by ❑ Subdivision drainage plan Waived b 20-003 (Rev. 01/02) -Bad OF AtXr �s`a • Dusn• Merk $*word LS ,6918 ..',g• d c t w aa�.w rw ASBUILT yoo mai cb+a� yat, r SEIdARD & I HEREBY CERTIFY THAT I HAVE SURVEYED THE SCALE' FOLLOWING DESCRIBED PROPERTY: AND THAT NO ENCROACHMENTS EXIST DATE= EXCEPT AS INDICATED. IT IS THE RESPONSIBILITY OF THE 8��6 OWNER TO DETERMINE THE EXISTENCE OF ANY GRID: EASEMENTS, COVENANTS, OR RESTRICTIONS WHICH DO NOT APPEAR ON THE RECORDED SUBDI- VISION PLAT. UNDER NO CIRCUMSTANCES SHOULD FB: ANY DATA HEREON BE USED FOR CONSTRUCTION OFFENCE LINES, OR FOR ESTABLISHING BOUND- ARY LINES. DRAWN: ops OF AtXr �s`a • Dusn• Merk $*word LS ,6918 ..',g• d c t w aa�.w rw I:' HEREBY CERTIFY THAT I HAVE SURVEYED THE FOLLOWING DESCRIBED PROPERTY: AND THAT NO ENCROACHMENTS EXIST EXCEPT: AS , INDICATED. IT IS THE RESPONSIBILITY .OF:THE - OWNER TO DETERMINE THE EXISTENCE OF "ANY EASEMENTS, COVENANTS, OR RESTRICTIONS WHICH DO NOT APPEAR ON THE RECORDED.SUBDI- VISION PLAT. UNDER NO CIRCUMSTANCES z SHOULD ANY DATA HEREON BE USED.FOR CONSTRUCTION .. OFFENCE LINES, OR FOR ESTABLISHING BOUND- ARY LINES. SCALE: GRID: FB: DRAWN:: , LAND SURVEYING 694-0 (✓ / 49P I �Q ^ �I(�((��, �J 490.0 /✓" ^9 O //� _ S3� �/IF Y !/✓�� 1 489.2 487.0 yo73 G/ w 5Ga 491 .5 9 r 54e.0 \ i/ .O / i 34/ t'S 493 I � / 4a 3.3 ► O �'J 5r7.0 v 0!, 416 /nVl a 1 SIa.S ('may . �Y4 497.2 403.5 P / 485.0 4e B4O / / I J i //431— 6 / ers.o efi 4e1s err o / Bi 2.J f /89.5 ✓'/. /82r.! / .. 6o / i30 BiTO / 1.5 $15.0 / R. RJ 805 624.5 Oi70 /� jgep,b� z2//. 757.7 L/' LY 0 0 V N ' 7 as • 00 Hiti�iii f {{{ a i e `[ teA 39 [9j�Fi T ��lil�7!p1V y!� t fig Ilii" 3 i f \ r .•y...� 6 �.., dam 6, �d tY � I l r SKI Aa. as l / !< � � I � � 6 � `r � � � N 1 � y I I � � ! • f . 4 .;K Iil re " s •a =i9 oaa91 �sa. ail 7� � plya 1 ��v'N LAt ° f w • • IA kw July 26, 2007 MOA Attn; Dan Roth RE; Scimitar Sub. Unit No. 1, Lot 6C, Bk. 2. I,s 1Gi -Y-n &) -!� EYn R1") owner of Lot 6C shall decommission the existing septic on Lot 6C before any new constniction on said lot. ,Notary Public O7 p11ARK� NOTARUS Y oO 99 PUBLIC O N. vlres 01.2309 Short Plat Summary of Action October 16, 2006 Page 2 of 3 1. Resolving Utility Easements. 2. Resolving with PM&E, the need to enter into a subdivision agreement with Private Development for any public improvements that may be required to Chugach Park Drive and Whaley Avenue. 3. Resolving with PM&E, the need to submit a site grading and drainage plan to resolve the need for drainage easements on the property. 4. Submitting information to On-site Water and Wastewater to satisfy the requirements specified by AMC 21.15, AMC 15.55 and AMC 15.65 for each lot within this proposed subdivision, which includes, but may not necessarily be limited to: a. Topographical information. b. Documentation for water availability to serve water wells. C. Documentation identifying areas designated for the original and replacement wastewater disposal system sites which meet all criteria specified in AMC 15.65 including slope and slope setback requirements. d. Soil testing, percolation testing, ground water monitoring to be conducted during high ground water season in either the fall (October) or Spring (May). e. As -built documents for the undocumented wastewater system and the undocumented water well on the property.' tnRo7��c� Z Relocating the driveway which services Lot 6C onto its own property. Tx-ACI- Submitting x-Ac l JJ.rc Submitting an as -built survey to Land Use Enforcement verifying compliance with yard setbacks with respect to proposed lot lines. 7• �- t �x It -28'6 Approval of the t for 18 month ject to the following conditions: 1. Resolving Utilit se 2. En 'ng into a main line extensio reement with AWWU to extend ublic water service to all lots within the 4 sed subdivision. \ Municipality of Anchorage • -� Development Services Department j Building Safety Division l.•i', S•.,. MEMORANDUM DATE: October 2, 2006 TO: Jerry Weaver, Jr., Platting Officer, CPD FROM: Daniel Roth, Program Manager, On -Site Water and Wastewater Program SUBJECT: Comments on Cases due October 12, 2006 The On -Site Water & Wastewater Program has reviewed the following cases and has these comments: S11536-1 Meyers Subdivision Information to satisfy the requirements specified by AMC 21.15, AMC 15.55 and AMC 15.65 must be submitted for each lot within this proposed subdivision. This information must include, but may not necessarily be \ limited to: 1. Soils testing, percolation testing, and ground water monitoring must be conducted to confirm the suitability for development using on-site wastewater disposal systems. Ground water monitoring must be conducted during high ground water season in either the fall (October) or spring (May). 2. Areas designated for the original and replacement wastewater disposal system sites must be identified and must meet all criteria specified in AMC 15.65 including slope and slope setback requirements for each lot. 3. Topographical information must be submitted. 4. Provide documentation for water availability to serve water wells. 5. The inspection report for the newly constructed wastewater system serving the existing home in the proposed subdivision has not been submitted to this office. This must be done prior to final plat sign off. 6. A well log and pump log for the existing water well has not been submitted to this office. This must be done prior to final plat sign off. S11537-1 Scimitar #1 Subdivision Information to satisfy the requirements specified by AMC 21.15, AMC 15.55 and AMC 15.65 must be submitted for each lot within this proposed subdivision. This information must include, but may not necessarily be limited to: 1. Soils testing, percolation testing, and ground water monitoring must be conducted to confirm the suitability for development using on-site Comments on Cases due 6/27/2007 Page 2 wastewater disposal systems. Ground water monitoring must be conducted during high ground water season in either the fall (October) or spring (May). 2. Areas designated for the original and replacement wastewater disposal system sites must be identified and must meet all criteria specified in AMC 15.65 including slope and slope setback requirements for each lot. 3. Topographical information must be submitted. 4. Provide documentation for water availability to serve water wells. 5. An undocumented wastewater system exists in the proposed subdivision that serves the existing home. An undocumented water well -serves the home also. These items must be documented and as -built documents provided to this office prior to final plat sign off. S11538-1 Mabel Hopp Subdivision Show potential water well sites for each of the proposed 7 lots that will meet the requirements of Anchorage Municipal Code 15.55. ld' \ Municipality of Anchorage Development Services Department / Building Safety Division ;{•"�: � a Sw [i♦ MEMORANDUM DATE: October 2, 2006 TO: Jerry Weaver, Jr., Platting Officer, CPD FRODf: Daniel Roth, Program Manager, On -Site Water and Wastewater Program SUBJECT: Comments on Cases due October 12, 2006 The On -Site Water & Wastewater Program has reviewed the following cases and has these comments: S11536-1 Meyers Subdivision Information to satisfy the requirements specified by AMC 21.15, AMC 15.55 and AMC 15.65 must be submitted for each lot within this proposed subdivision. This information must include, but may not necessarily be limited to: 1. Soils testing, percolation testing, and ground water monitoring must be conducted to confirm the suitability for development using on-site wastewater disposal systems. Ground water monitoring must be conducted during high ground water season in either the fall (October) or spring (May). 2. Areas designated for the original and replacement wastewater disposal system sites must be identified and must meet all criteria specified in AMC 15.65 including slope and slope setback requirements for each lot. 3. Topographical information must be submitted. 4. Provide documentation for water availability to serve water wells. 5. The inspection report for the newly constructed wastewater system serving the existing home in the proposed subdivision has not been submitted to this office. This must be done prior to final plat sign off. 6. A well log and pump log for the existing water well has not been submitted to this office. This must be done prior to final plat sign off. S11537-1 Scimitar#1 Subdivision Information to satisfy the requirements specified by AMC 21.15, AMC 15.55 and AMC 15.65 must be submitted for each lot within this proposed subdivision. This information must include, but may not necessarily be limited to: 1. Soils testing, percolation testing, and ground water monitoring must be conducted to confirm the suitability for development using on-site Comments on Cases due 6/27/2007 Page 2 wastewater disposal systems. Ground water monitoring must be conducted during high ground water season in either the fall (October) or spring (May). 2. Areas designated for the original and replacement wastewater disposal system sites must be identified and must meet all criteria specified in AMC 15.65 including slope and slope setback requirements for each lot. 3. Topographical information must be submitted. 4. Provide documentation for water availability to serve water wells. 5. An undocumented wastewater system exists in the proposed 'subdivision that serves the existing home. An undocumented water well serves the home also. These items must be documented and as -built documents provided to this office prior to final plat sign off. S11538-1 Mabel Hopp Subdivision Show potential water well sites for each of the proposed 7 lots that will meet the requirements of Anchorage Municipal Code 15.55. Short Plat Summary of Action October 16, 2006 Page 2 of 3 1. Resolving Utility Easements. 2. Resolving with PM&E, the need to enter into a subdivision agreement with Private Development for any public improvements that may be required to Chugach Park Drive and Whaley Avenue. 3. Resolving with PM&E, the need to submit a site grading and drainage plan to resolve the need for drainage easements on the property. 4. Submitting information to On-site Water and Wastewater to satisfy the requirements specified by AMC 21.15, AMC 15.55 and AMC 15.65 for each lot within this proposed subdivision, which includes, but may not necessarily be limited to: a. Topographical information. b. Documentation for water availability to serve water wells. C. Documentation identifying areas designated for the original and replacement wastewater disposal system sites which meet all criteria specified in AMC 15.65 including slope and slope setback requirements. d. Soil testing, percolation testing, ground water monitoring to be conducted during high ground water season in either the fall (October) or Spring (May). e. As -built documents for the undocumented wastewater system and the undocumented water well on the property. Relocating the driveway which services Lot 6C onto its own property Submitting an as -built survey to Land Use Enforcement verifying compliance with yard setbacks with respect to proposed lot lines. tnRo?.>r�c� SR-f�sF��s It -28-6 Approval of the t for 18 month ject to the following conditions: 1. Resolving Utilit sei 2. En ng into a main line extensio reement with AWWU to extend ublic water service to all lots within the osed subdivision. Eagle River Engineering Services Christopher R Wood, P.E. 10421 VFW Rd., Suite 201 (907) 694-5195 tel Eagle River, AK 99577-3294 (907) 694-3297 fax www.eres-ak.com 31 May, 2006 To: Garald and Sharon Tieman, PO Box 362 Chugiak, AK 99567 Cc: Mr. Dan Roth Manager, On -Site Services Municipality of Anchorage PO box 196650 Anchorage, AK 99519 Re: Scimitar Subdivision Unit No.1, Lots 6A, 6B, 6C, Block 2. On-site Water and Wastewater Disposal Subdivision Soils Report Dear Mr. and Mrs. Tiernan and Mr. Roth, Eagle River Engineering Services (FRES) is pleased to present you with this On -Site Wastewater Disposal Soils Report, for the proposed subdivision of Lot 6 of the above named subdivision, into Lots 6A, 6B, and 6C. ERES was contracted by Mr. & Mrs. Tieman to perform a soil investigation for the proposed subdivision to determine the feasibility and suitability of the proposed lots to support on-site wastewater disposal systems and private wells. OVERVIEW The Lot 6 subdivision consists of splitting the existing parcel into three lots that vary in size from 1.28 acres, to 1.94 acres. Test holes were excavated on the proposed Lot 6A and Lot 6B. An existing wastewater system is present on lot 6C. We are presenting the soil log conducted during the permitting of this wastewater system for the test hole for lot 6C. Test holes were excavated by Dean Construction, with a rubber tired backhoe with extend -a -hoe. These test holes were logged by Chris Wood of ERES in early October, 2006. Soils percolation tests were performed adjacent to these test holes, with water table monitoring conducted through the end of October, 2006. SUMMARY OF FINDINGS The following represents a summary of our findings. Scimitar Subdivision Unit No. 1 Lot 6A -6C, Block 2 lies on near the base of Bear Mountain in Peter's Creek, East of the Glenn Highway, and South of Mirror Lake, and North of the Peter's Creek drainage. The proposed subdivision has a sparse cover birch and white spruce forest where it hasn't been cleared, with occasional cranberry and alder patches. The underlying soil encountered can be characterized by being brown sand & gravel with some cobbles, underlain by brown and/or tan very tight silt. UCS classification would consider this upper soil layer to be SW -GW. This free -draining soil deposit varies in depth, and appears to be underlain with very tight silt. The topsoil layer was found to be approximately 1'-3' in depth. Our test hole evidence shows this free -draining soil layer to be absent in the North-West corner of this proposed subdivision, and recommend that this area be reserved for on-site wells (see site plan). Satisfactory percolation results were obtained for each lot, with the exception of test hole #2 on the western half of Lot 6B. Groundwater was found in the abandoned test hole (#2), but was absent in test hole #1 and #3. This groundwater was monitored during our observation period of October, 2006. No surface water was noted within the confines this proposed lot subdivision, nor within 100' of the proposed wastewater disposal area. The proposed subdivision's topography only exceeds 25% slope along a slope break in the south- east comer of the proposed subdivision, and along the Lot 6A and 6C lot line. There is ample room on each of these lots to construct wastewater disposal systems that do not encroach on these slopes steeper than 25%. With the exception of the above mentioned slope breaks, the remainder of the topography is gently sloping west, not exceeding 25%. We believe the two new proposed lots can safely support a primary and two replacement on-site wastewater disposal fields, and the existing lot and septic system has room for replacement sites. Lot size exceeds 40,000 square feet (minimum lot size required for installation of an on-site wastewater disposal system) on all three lots. ON-SITE WASTEWATER DISPOSAL RECOMMENDATIONS ERES has confirmed that suitable soils and area exist on all three lots conforming to Anchorage Municipal Code Chapter 15.65, and can provide a safe wastewater disposal systems that are protective of human health and the environment. Due to the underlying layer of silt, the wastewater disposal systems will most likely be drainfields with up to 4' of sewer rock, or possibly a bed -type system for lot 6 B. All lots may require a 2' sand filter. Lot 6 C's replacement systems may require the use of a Category III system in order to meet all lot line, well, and slope setbacks, unless the existing structure is demolished, and the well moved farther away from the proposed septic sites. WATER SUPPLY Several well logs were obtained in the general area of this subdivision and have been included for your review. Well production rates appear to exceed 1.8 gallons per minute on adjacent lots, with the exception of the well on Lot 5. We anticipate the wells to be around 200 feet deep. We do not believe that the development of two new lots will adversely impact the water availability on adjacent lots due to the sparse spacing of wells in the general vicinity, and the nature of the recharge of this aquifer. NITRATES ERES has found Nitrate concentration information on the lots surrounding this subdivision. ERES does not believe the construction and use of on-site septic systems on the proposed lots in this subdivision will adversely affect the surrounding lots' potable water supplies. The aquifers are protected by glacially over -consolidated layers of silt (hardpan) that are virtually impermeable. Nitrate levels are of several surrounding lots are included for your review, and range from 2.67 to 3.8 mg/L. LIMITATIONS Test hole findings reflect local conditions at the test boring locations only, and are subject to natural variations and changes. Conditions during leachfield installation may be different from those found in the test holes, and must be designed around accordingly. ERES appreciates the opportunity to provide you with continuing services on this project, and is looking forward to working with you on future projects. Please contact us if you have any questions. We can be reached at 694-5195. Sincerely, EAGLE ENG SERVICES nstopher R. Wood, P.E. Principal 1 - - a Q' ff ` �NN i , I �� •• `♦♦ �' `♦ / 0.y' �•• d o • i S Ob Vk, EZYz► - LO 3.00.00. to N 118 a t + I6 i•.. a `96 � Ix i s � �Wyn n C � I O W W\e•f • • ` •ii♦\v •t �y:'1' . • i ". 1 0 J J � M I � 1 ,•. ? i�+� � I z � a LJ �.. 8 U Im i � ♦` <, � • SFW 00 C) 1 h lL'S6L M.S N E O 03C +a i 1 i •v �,. Z E m o 1t> z N -'� ` i--------- J �Z 0 u I i p ♦ `v �\ ♦` 0. LZ i < ,�, .♦ -` Ino �♦ , C ,♦ F x i ♦ W p a q1 �� O♦ 0' ig41W N � 0 n^ 8clfco 00. La D_ (nZ< Ir < to 8 p ®�o � 2 pyo ¢ IIII W� EAGLE RIVER ENGINEERING 10421 VFW RD. SUITE 201 EAGLE RIVER, AK. 99577 (907) 694-5195 FAX: (907) 694-3297 SOILS LOG - PERCOLATION TEST OF '.CHRISTOPHER R. W000. CE -10387 PERFORMED FOR: SHARON TIEMANDATE PERFORMED 10/08/200 �� LEGAL DESCRIPTION:_SCIMITARNi LOT 7 BLOCK 2 TOWNSHIP RANGE SECTION T15N.R1W.SEC.10 TES7--- nre.0 1 TOPS L 18 19 21 WAS GROUND WATER ENCOUNTERED? NO WATER TABLE DATA DATE WATER LEVEL 10/08/2006 NONE 10/09/2006 NONE 10/19/2006 NONE LOT GA wi PERC TEST RESULTS V LOT M LOT SG READING JDATE IGROSS TIME INET TIME IDEPTH TO WATER TNETDROP PECOLATION RATE WAS FASTER THAN 1 MINUTE PER INCH PERCOLATION RATE- >1 (Mrw" PERC HOLE DIAMETER=S' LEST RUN BETWEEN 4 FT AND 5 FT COMMENTS: 2' FILTER SAND REQUIRED SOIL L �G _ yg! TOPHER WOOD PERCOLATION TEST BY: CHARLES BALZARINI I CERTIFY THAT THIS TEST WAS PERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE. DATE: Q4- TAN LOESS/SILT J o '10 4 •o' a. S ' BROWN -G W B o `•` [[S55W COARSANDGRAVELO S011E COBBLES 7 0' 8 0 9 Or• f0 tt ' TAN SILT 12r .MO GRAVEL 13 14 18 19 21 WAS GROUND WATER ENCOUNTERED? NO WATER TABLE DATA DATE WATER LEVEL 10/08/2006 NONE 10/09/2006 NONE 10/19/2006 NONE LOT GA wi PERC TEST RESULTS V LOT M LOT SG READING JDATE IGROSS TIME INET TIME IDEPTH TO WATER TNETDROP PECOLATION RATE WAS FASTER THAN 1 MINUTE PER INCH PERCOLATION RATE- >1 (Mrw" PERC HOLE DIAMETER=S' LEST RUN BETWEEN 4 FT AND 5 FT COMMENTS: 2' FILTER SAND REQUIRED SOIL L �G _ yg! TOPHER WOOD PERCOLATION TEST BY: CHARLES BALZARINI I CERTIFY THAT THIS TEST WAS PERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE. DATE: Q4- EAGLE RIVER ENGINEERINGtRWOOMO 10421 VFW RD, SUITE 201EAGLE RIVER• AK. 99577 (907) 694-5195 FAX: (907) 694-329710, .SOILS LOG - PERCOLATION TEST '+; s '�" CE103 PERFORMED FOR: SHARON TIEMAN DATE PERFORMED 10/08/2006 1�1� ESSION:�� LEGAL DESCRIPTION:_ SCIMITAR #1 LOT 7 BLOCK 2 TOWNSHIP RANGE SECTION T15N.R1W.SEC.10 TEST HOLE If 2 SLOPE DEPTH SITE PLAN(NOT TO SCALE? 12 13 14 18 t8 19 21 WAS GROUND WATER ENCOUNTERED? YES WATER TABLE DATA DATE WATER LEVEL T0-10812006 NONE 1010912008 8.2' 10/18/2006 8.3' LOT !A 11 LOT N d: SOILS PHER WOOD • PERCOLATION TEST BY: CHARLES BALZARINI I CERTIFY THAT THIS TEST WAS PERFORMED AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE. DATE: -6N ACCORDANCE WITH ALL STATE Q;L BROWN 1 TOPSOIL 2 m:. � o 55 4 . SILT AND SAND s •y, a- 7- 7 B ° •' •, C SILTY GRAVEL 10 ° e °.;';• TC11T TAN SILT AND SAND 12 13 14 18 t8 19 21 WAS GROUND WATER ENCOUNTERED? YES WATER TABLE DATA DATE WATER LEVEL T0-10812006 NONE 1010912008 8.2' 10/18/2006 8.3' LOT !A 11 LOT N d: SOILS PHER WOOD • PERCOLATION TEST BY: CHARLES BALZARINI I CERTIFY THAT THIS TEST WAS PERFORMED AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE. DATE: -6N ACCORDANCE WITH ALL STATE Q;L EAGLE RIVER ENGINEERING 10421 VFW RD, SUITE 201 EAGLE RIVER, AK. 99577 (907) 694-5195 FAX: (907) 694-3297 SOILS LOG - PERCOLATION TEST PERFORMED FOR: SHARON 71EMAN DATE PERFORMED 10/08/2006 LEGAL DESCRIPTION: SCIMITARNI LOT 7 BLOCK 2 TOWNSHIP RANGE SECTION T15N.R1W.SEC.10 TEST HOLE �/ 3 - -- 1 TAN CLAYEY �}^^� SILT AND LOAM 3 ° . u... SW/GW 4 f' • BROWN SAND AND GRAVEL S 6- 7 . VN 10 11 12 13 14 18 19 21 WAS GROUND WATER ENCOUNTERED? NO WATER TABLE DATA DATE WATER LEVEL 1010812006 NONE 10/09/2008 NONE Tom 912 006 NONE LAT GA V PERC TEST RESULTS TION RATE WAS LOT 6C 1 MINUTE PER PERCOLATION RATE- >1 (MNINCHQ PERC HOLE DIA ETER=B' TEST RUN BETWEEN 3 FT AND 4 FT COMMENTS: 2' FILTER SAND REQUIRED S01 D STOPHER WOOD PERCOLATION TEST BY. CHARLES BALZARINI I CERTIFY THAT THIS TEST WAS PERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE. DATE: ZZ -90 / ' SOILS LOG MUNICIPALITY OF ANCHORAGE • DEPARTMENT OF HEALTH AND ENVIRONMENTAL PROTECTION 0 PERCOLATION ` 929 L Stmt, AMhorape, Ab,k, 98901 291-1720 TEST SOILS LOG - PERCOLATION TEST PERFORMED POR:�5 rf VC/V S'%(/�(�' (• /Vl,•rr� DATE PERFORMED: G o s LEGAL DESCRIPTION _�� % [J /� �GK�•• � � S•/ � Nn f � /7 Off" PL SLOPE SITE PLAN 1 �L 2 3 I b � I 6 �� Gw/Gv 0 6 0 �. 7 8 WAS GROUND WATER _YES L ENCOUNTERED) O P IF YES, AT WHAT / E DEPTH? PERCOLATION RATE (minumsfirmh) TEST RUN 0EEN FT AND F PERFORMED BY: 72%�i •�X\/F/2l41b4AL-CERTIFIED BY: DATE: 72.009 Isf7/) N Print Map Page I of 1 http://munimaps.muni.org/mox42/pAdmin.cfm?action=mox42 view_printablcmap 12/14/2006 Lot 05 http://onsite.ci.anchoragc.ak.us/scripts/LF WcbLink.exe/webl ink/defa... AT ,ler#ift.eb Brining ` kvg by 0900.4116 SULLIVAN WATER WELLS P.O. V0X eTO2ri, ONUOIAK, ALUM 11.1N a T1LtrMON1111 111-,T/t OWNER OF LAND ADDRESS LEOAL DE80RIPTION La -r -C PERMIT NUMBER!M Oe Q Dele of law }L•� TAX INDENTIFICATION NUMBER QTJ 3e1,s b tw'I bated et approved perr(M toattion) 9-yre O No Method of Dladtp: E7 [fr rohN p cable tool Depllt of W611: 406 Cil*V Type jj&&A W611 Thiokne« Vnohes Diameter Z A Inches, de*—Jt; f. �/� 1061 Urtaf ype: �odbrJi Caving Stickup Above Ground: ,a_ Jolt Step Water level (from ground level); 7 teat Pumping levet; feet Mur.hre. pumping gtfA Recover Rats .AA cpm MetnodofTheting: 0qlAa V(bll IMeka opening Type: C7 Open End VAMon Hob (3 8a«n6d; Brettteat Slopped n feet �-rSAonttone Burt `7� feet 8lopt»d,�jc_1«t OroutTyPMA&LmdIr- Volun»^ J.±OL& -- Depth: from f«t, to flet Pump Intake Depth: feet Pump SlaO hp &and Nems Well Dfalnfected Upon COMP*t)on7 OYu C) No •----Mtrmctprntt�vr><rtamR�e— Mlethod of Disinfection: wept. Heeltn itumen Services Comments: p.ttat0/If/t! _ ,p�T•e N»t DrpbfeName, li..r-+ i✓` '� ATTENTION: It It the na"nslbnny of the property owner to submit a copy of the well log to the proper sutlbnty. Munwitellty of Anchorage: E vplrtrvmmt of CcnehNNbHuman SatvkOa andW Department of Envlronroentsl Canservatlon. MatBu Borough: Department 12-4 f►►►►►►►rblftClZ 06e a119M ramIum N11n191na NV IbifY'N �Page Fjof30Mj Powered by LaserFiche WebLink v7.01: Registered to City of Anchorage 2 of 2 12/07/2006 5:16 PM DEC -20-08 01:20 FROWCTE EMVIRM11TAL C rAE Ret► Client Nene Project NameM Chem Sunple 1D Metrix Ordered By FW9W ME Environmental Services Inc. 987273003 Anderson Engineerw PVA let 5 Block 2 Sdiattar Dr{akitig Water 0 6616101 T-250 P.02/01 h -1e1 Client PON "tcel V410%c %c 12/28/98 12:26 Collected Dateffinae 12/17/98 13:55 Reedved Dete/lyme 12/17/98 16:25 Teal Dtreetor. Stephen C Ede Releecad By atl/wabte Prep arrtysis Paruetor 8esutte POL unite Method LIMITS Date Date Init Mltrate-e 2.e7 0.100 ter/L EPA 300.0 10 Man ' 12/22/P6 12/17/98 !Oe 70tat Cot110re 0 COMOOM swig 92228 12/17/98 ANY f/P •a n0tri-Ou w �n4. � dee � . � � •v MUNICIPAUTY Of AN4't0:t.0; LRONWNTAL PROI C.*N (� NVIprtifirb Brilltoup Ivrg APR 1 i 1911 by ^ A & L DRILLING COMPANY 1`E C E I V— ,' BOX 97, EAGLE RIVER, ALASKA 99877 • TELEPHONE 694.2688 .: �• "'' OWNLR OF LAND(.;(::,t%/./) //: r;://Qr./ DEPTH OF WELL ADDRESS / %' t L .:Z i ' Jt4'/ rt !/!jj'�;) STATIC LEVEL OF WATER FT. 1 ' LEGALDESCRIPTION e !;!./•J �f1o//'1i111 DATE -Started � S �' Ended PERMITNUMBER 72112 KIND OF FORMATION: DRAW DOWN FT GALS. PER fill 4 •)C) KIND OF CASING From f t Ft. in Ft. nc1G',•1F•r,R//t"+0 Froin—Ft. to Ft. From Ft. to 1 Ft.��/rP(r (.l.?i1ur,`t. From Ft. to FL From : ''r FL to Z1 Ft. _t%A)'f 0%( (, 011 UL __ Front --Ft. to Ft. From .r"' Ft. to—LL—Ft. (•` ( "i )' From Ft. to F4 From—ii—Ft. to,`L5_Ff. t From FL / tu_/%�Fl.—.� r From /(. Ft. to r/ Ft. �t'1" �J �' (r 11 r1 ,111.. From— :'%1f.FFom From _Ft. to " !f" r"FL to Ft. to Ft. Ft. Ft. il... rl (, GJ,/aia ♦� . ri..t I a: (t ,'1✓t.� From 10 Ft. to :) /)" Ft.- From Ft. to Ft. From—Ft. to Ft From Ft. to Ft., From Ft. to Ft. From Ft. to Ft.. From Ft. to Ft. From Ft. to Ft.. From Ft. to Ft. From Ft. to Ft.. From Ft. to Ft. From Ft. to Ft.. From Fl. to FL From Ft. to Ft.. From Ft. to Ft. From Ft. to Ft.. From FL to Ft. From Ft. to Ft. _ From Fl. to Ft. From FL MISCL. INFORMATION: DRILLERS NAME ' ta�io--w�A�H_ra.�trcz. WiLS04,WELL DRILLING ANCHORAGE. ALASKA GV&" 9FSO7 PHONE ---if" OWY Well Owner Location (address of: Township, "�fi'-r- 'DRILLING LOG use ofWcl if known; or distance main road---- 'DRILLING oad h eet Cased to Qa feet Size of cashng� Depth of Holc Static water level ---------f L (above) (below) land surface. Finish of well (check one) open end ( ) Screen ( ); Perforated ( )• Describe screen or perforatior— Well pumping lest aL-5—gallons per (hour) of drawdown from static level. Date of completion -a (a- j� Depth in feet from --- .._.. _...r.,.... _JJ' TO__5ia-- SS_� TO07 -tL _7I)4•-�i To __¢_Jr TOJ Cl;�—TOJQt= TO t —TO O 1 J ST Lc 4 t TO� t � a•.f�l—To.�.�— TO TO err) (minute WELL LOG EtN.tJt�A 6 iFQI FEe'c•`�ti� Give details of formations penetrated, size of material, color and hardness c_6: •. FN s t '1 _"f: e, n"r 1 AA n. one � Vd. CVPA .. Q,4 CHEMICAL & GEOLOGICAL LABORATORY A DIVISI0N OF C0MMERCIAL TESTING & ENGINEERIN0 CO. 6833 B STREET ANCHORAGE. ALASKA 98818 TELEPHONE (907) 602.2343 FAX: (907) 681.6301 ANALYSIS REPORT It SAMPLE for NOREoidert 15170 Data Report Printed: JUN 17 911 14:SS Client Semple IMES 11 SCIMI7A1 S/D 11 Client Nemo is 6 S ENGINEERING PNSID 1UA Client Beet :SNSENCP Collected JUN 11 91 1 17:00 bre. APO t t0 1 NONE REC1ITID Recelred RUM 14 91 4 11:50 big. ley I ?received with tAS REQUIRED ordered By :l. SRAFER Analysts Completed :JUN 14 91 Send Reports to: Laboratory Super is C. EDt 1)S 9 S INGINEEAING Raleased By t iW�i %&-- 1) ................................. -.................................---..........................................................--•- Chemleb Ref I: 911744 Lab Smpl to: 7 matrix: MATER Parameter Tested Result Units Method _•______________________________________•__-__-_-•_----- -___----______---__.-' NITRATE -N 3.7 p/1 EPA 151.1 Sample ROUTINE SAMPLE COLLICTIO II: SAI. Remarks: Allowable Limits 10 .............................................................................................................. 1 Tests Performed See Special Instructions Above UA -Unavailable ND- None Detected •• Su Semple Remarks Above NA. Not Analysed LT -Leu Than. CT-Crsater Than :�1 S^S Member of the SGS Group (SocldtA Odndrele de Sunelllance) • M -SIN DRILLING, P.O. Box 4.1224 • 1310C Int.rnril (907) 274.4611 ANCHORAGE, ALASKA DRILLING LOG Post -I. rrand tax transmittal memo 7671com- rotp.ps. / anv ty ••m 9.'l�/�iaori_ (Sic o6pl. root %bis /s d(nt .Y ,. (2eolT7M,11A• ,-ef Yl. Well Owner Mr knlul.,i n Use of Well flnm - Location (address of: Township, Range, Section, if known; or distance maln roars 1.5. ScimiSy:lrbd iv.. Size of casing _"i__Depth of Hole 1 RS rect Cased to_176_ feet Static water level 16A *t. (abov4 (below) land surface. Finish of well (check one) open end ( x ); Screen ( ); Perforated ( . ). Describe screen or perforation d NnnP _— ll'1r'r' f a. Well pumping teat ar 9 gallons per (hour) (minute) for—L--hours with t. of drawdown from static level. Dale of completion_ 25 d%oov 74 WELL LOG Depth In fect from ground surface Give details of formations penetrated, size of mster!aI, color and hardness o —TO--11L- -To TO_ lr_TO 16 16v:TO SO S075TO 75 7�i TO 8-5_ _ 8-5— S% TO—Q= 11 r' TO_ 1 O- —_L�L?_TO l07 __1_07 TO ,_1270---12CJ _ ,2Q._T0 12 5 _ _U3—TO--122— --121TO IL70 TO ).LIG ,i ltv Gl•avr•1 • n d.j.y,.__ Sands' wet _ Silty .^,ravrlt nCCF•aio� nr-1 COl,t�lrtc, nightly SantY Hardpans cobbly1�••ravell Boulders Gravelly Ifardlsnls Loose caravel _ C,ravplly hard an obbl Poulders Gr....nlly HTrrinntLt cobbly_ r•1 nv 110u1der c:rnvel t wAterhPnring 4...1 rnr1: 3 ^ CONTRACTO 4 � CHEMICAL & GEOLOGICAL LABORATORIES or, ALASKA, INC. 8873 B STREET ANCHORAGE, ALASKA 98518 TELEPHONE (007) 562.2343 y , wo.-.Nw..• FEDERAL TAX ID a 92-0040440 ANALYSIS RIPON IT SAMPLE for Kork Order 1 9121 Data Report Printed: SIP 14 88 a 09109 Client Sa*Pls ID:L% 11 SCIMITAR 11 MID EUA Collected UP 8 80 a 15:45 bit. Recolyod SEP 9 88 1 15:00 bre. Prasetyed alth 14 DEO. C Analysis Coupleted :SLP 12 18 Laboratory Supory lot :STIPUEU C. EDE Released IY : is f y-... C, y��.. Chant Dane 1 S 6 3 InOINEIRINO Client Acrl 1 SIISEUOP P.0.1 NOIIP. RLC' D Rai t Ordstud Iy : RJ3 Sand Report$ to: 1)S D S LIIGIIIY,ERIUC 2) D....................,.,n....,......,........,,,,........,..........N..,,..,,...............,.......,................... ,w..,,....,e.. Special Instruct: Choalab Rof 1: 2546 Lab UpI ID, 1 Paromator Tasted NITRATL-N Simple ROUTINE SAMPLE lonork : MUM COLLECTED 1T I13 Nauta: NAT91 Allavablo Raoult/Unite Nethed Limit$ 3.0 0l/1 EPA 353.2 10 v'. ---+wA •Tests-Patfornod •'•..,.....,. •-SooYSpocial•Inshuctiow Aboyo•-••'--IIA-Unayailnble ••w-•-••------- ND- Non* Detoated '• Soo Sample Rawrko Aboio HA- Not Analysed LT -Looe Thnn, 0T•Oreater Than NORTHERN TESTING LABORATORIES, INC. V-A] 33301NIAMMAL AVENUE FAIRBANKS• ALASKA 99701 (907)35381/3 . FAK %533125 2505 FAIRBANKS STREET ANCHORAGE, ALASKA 99503 (907) 7778373 a FAX 27449645 Constructing Engineers 9601 Buddy Werner Drive Anchorage AA 99516 Attnt - Our Lab Ot A121073 Location/Project: - Your Sample ID: L4 Marie Eat Sample Matrix: Water Comments: Report Datet 10/22/92 Date Arrived: 10/16/92 Date Sampled: 10/15/92 Time Sampled: 1520 Collected By: CAL MDL - Method Detection Limit Flag Definitions B - Below Regulatory Min. H - Above Regulatory Max. E - Below Detection Limit Estimated Value Date Method Parameter Units Result Flag MDL Analyzed ----------------------------------------------------------------------------------------» EPA 353.3 Nitrate -N mg/1 3.8 1.0 10/20/92 R o tad By: Susan,C. T nta H c biology Superviso