Loading...
HomeMy WebLinkAboutLAKE O THE HILLS BLK 3 LT 2Lake O' The Hills Block 3 Lot 2 #015-331-23 Municipality of Anchorage On-Site Water and Wastewater Section • (907) 343-7904 Page 1 of 3 ON-SITE WASTEWATER INSPECTION REPORT Permit Number: OSP181320 PID Number: 015-331-23 Dwelling: X Single Family (SF) 9 with ADU ❑ Duplex (D) ❑ Two Single Family Project: 9 New ❑ Upgrade Name Ryan & Lindsey Callaway ABSORPTION FIELD ❑ Deep Trench ❑t Wide Trench ❑ Bed ❑ Mound Site Address 11200 Briggs Court Anchorage, AK 99516 ❑ Other Phone Number of Bedrooms Soil Rating Total depth from original grade 276-1911 1 1.2 PD/SF 6.9 Ft. LEGAL DESCRIPTION Depth to pipe invert from original grade 2.9 Ft. Gravel depth beneath pipe 4.0 Ft. Subdivision Block Lot Lake O The Hills 3 2 Fill added above original grade 0.0 Ft. Gravel length 15 Ft. Township Range Section Gravel width 5.0 Ft. Beds: Number of Lines Distance between lines Ft. SEPARATION DISTANCES To Septic Absorption Lift Station Holding Sewer Total absorption area Number of trenches Dist. between trenches From Tank Field Tank Line 150 FtZ 1 Ft. Well >100' >1 00' N/A N/A >25' TANK A Septic ❑ S.T.E.P. ❑ Holding ❑ Other Manufacturer Anchorage Tank Capacity 1,000 Gal. Surface Water >100' >1 00' N/A N/A Material Number of compartments Lot Line >5' >10' N/A N/A NA Steel 2 Foundation >10' > 1 0' N/A N/A LIFT STATION Manufacturer Capacity Gal. Remarks All inspections done on same day. Tank and trench are insulated. This IR is for the septic that is serving an ADU. Alarm location Electrical installed by PIPE MATERIAL House to tank D3034 Tank to drainfield D3034 Installer Wilco Contractors Drainfield D3034 CO/MT D3034 Inspector J. Mlllette BENCH MARK (Assumed elevation) 100 ft Inspection 15` 11/20/18 Location and description nd r Top of foundation @point A. 34'n ON-SITE WATER AND WASTEWATER SECTION APPROVAL Engineer's Stamp .e�-S OF 14 eae® ®# Conditional Approval: Date d•�P.•••'"'• •qS ,r . 49th - • 0. .00 WT 10 ®...... ................................ : %� ;•MICHAEL E. ANDERSON ♦ !f, No. CE-4381 AW ®� T� '°••.., Se tic S stem p y 9&M Approved Date 3 f �0� D 2/11/20 •.••°<���® ®4 Note: this approval does not include well permit requirements. +®®MHz's ae►*®410,® (Rev Ub/U"L/16) LAKE O THE HILLS B3 L2 PERMIT # OSP181320 PID # 015-331-23 EXISTING SEPTLC_ SYT EXISTING Cl l \ �ERVINGTHD�SE\ LL A \ LOT 1 ALTERNA4E SIT svi y, sv2 TH-A2CO 1,000 GALLON MT , SEPTI�ANK _ / T� 15' LONG X 5' NIDE X 4' / / EFFECTIVE DEPTH 'ABSORPT N TRENCH. LOT 10, UIIL EASEMENT I I ENGINEE.ING ••••49th �••��••�� .......... .... ■....r �.....� � ................................................ . .■ MICHAEL E. ANDERSON = •� •p No. CE -4381 ••• _AV �� TF 2-4-20 .• ° •��' •PROF ESS PLAN AS -BUILT 0 50 100 FEET 111=50' FCO 3.5 31.1 SV1 25.3 48.6 SV2 29.6 53.3 2CO 34.3 57.9 C01 40.2 63.5 MTI 54.9 751" CO2 i 55.8 7 CO - CLEANOUT 2CO - DOUBLE CLEANOUT FCO - FOUNDATION CLEANOUT FS - FLOW SPLITTER VALVE MH - MANHOLE MT - MONITORING TUBE SV - SEPTIC VENT TH - TEST HOLE LAKE O THE HILLS B3 L2 PERMIT # OSP181320 91.2 GE ENGINEERING PI D # 015-331-23 " INSULATION O 2" INSULATION O U� 94.1 FINISH/ ORIGINAL GRADE v DRAINFIELD ROCK X87.2 87.2 �-- 151 78.1 NO GROUNDWATER 8/27/18 PROFILE AS -BUILT (NO SCALE) 91.2 ............... 4 � � °• 49th �1 •�'• �•�� L...1. ..... ......... .... .a.....� �.....y.................................... ' MICHAEL E. ANDERSON � � i •���5 4 NO. CE -4381 ••• _AV 2-4-20 ............... ,.•••• •t 14','iii SS \ •••• R=150' 1 `Septic Vents �y os d �7 O O 0 UBF f QUsE .0 SXISStNC' Fi o Well o r�CQ .:- e - a $ Q) `y • '9i ti DO 0 I hereby certify that the property described hereon has been surveyed .4O , ` , by me, or at my direction, and that the improvements situated thereon are within the property lines and do not overlap or encroach on thetk s� property lying adjacent thereto unless otherwise shown. That no � 11 improvements on the property lying adjacent thereto encroach on the premises in question and that there are no roadways, transmission T1 lines or other easements on said property except as shown. It is the responsibility of the owner or builder, prior to construction, to verify proposed building grade relative to finish grade and utility BOBBY F.- 19= 04 connections and to determine the existence of any easements, covenants, U' LS -5484 or restrictions which do not appear on the recorded subdivision plat. ZC" AO \,..'�Reprodu�ctionmay ed stprevail �distortion. caling.SSIONALI cause �O Gj N 680 70, O 0017 54" W GRAPHIC SCALE. I Inch = 50 Feet 24S" FSl1gT k75 7 10o 1i 25 50 r10>0 Date Scale Legal Description 4/5/2019 1" = 50' Lot 2 Block 3 Bobby F. Burnett RLS Grid AS—BUILT 2941 Carriage Drive SW 2639 Lake O' The Hills Anchorage, Alaska 99507 Drawn by Field Book Subdivision (907) 350-5541 BFB ASB2019 I hereby certify that the property described hereon has been surveyed .4O , ` , by me, or at my direction, and that the improvements situated thereon are within the property lines and do not overlap or encroach on thetk s� property lying adjacent thereto unless otherwise shown. That no � 11 improvements on the property lying adjacent thereto encroach on the premises in question and that there are no roadways, transmission T1 lines or other easements on said property except as shown. It is the responsibility of the owner or builder, prior to construction, to verify proposed building grade relative to finish grade and utility BOBBY F.- 19= 04 connections and to determine the existence of any easements, covenants, U' LS -5484 or restrictions which do not appear on the recorded subdivision plat. ZC" AO \,..'�Reprodu�ctionmay ed stprevail �distortion. caling.SSIONALI cause N,"°""'yoF MUNICIPALITY OF ANCHORAGE ' On-Site Water&Wastewater Program : PO Box 196650 4700 Elmore Road , Anchorage,Alaska 99519-6650 Phone:(907)343-7904 Fax:(907)343-7997 z.. http//www.muni.org/onsiteeRtY _ rtat 1)c•paI tmcnt 4�`CMON pVE On-Site Wastewater Disposal System Permit Permit Number: OSP181320 Effective Date: 9/14/2018 Work Type: Septic Initial Expiration Date: 9/14/2019 Tax Code Number: 01533123000 Site Legal Address: LAKE 0 THE HILLS BLK 3 LT 2 G:2639 Site Mailing Address: 11200 BRIGGS CT, Anchorage Owner: CALLAWAY RYAN & LINDSEY Lot Size in Sq Ft: 54458 Design Engineer: FORGE ENGINEERING Total Bedrooms: 1 This permit is for the construction of: Q Disposal Field El Septic Tank ❑ Holding Tank 0 Privy 0 Private Well 0 Water Storage All construction shall be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72)and Drinking Water Regulations (18AAC80) 3. The wastewater code requires inspections during the installation. The engineer shall notify the Development Services Department per AMC 15.65. Provide notification by calling (907) 343-7904 (24/7). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather shall be either: a. Opened and Closed on the same day, or b. Covered, sealed, and heated to prevent freezing Received By: }P "QlgQ Date: / 7 i Issued By: fliktOjk epotA Date: 61 El? MUNICIPALITY OF ANCHORAGE Community Development Department ri Pho • '% "49- Development Services Division : .gialif q On-Site Water & Wastewater Program SEP 10101d 3 ON-SITE SEWER/WELL PERMIT APPLICATION g _ d ti Parcel I.D. 015-331-23 4 a6 8 L 9 5� Property owner(s) Ryan & Lindsey Callaway Day phone 276-1911 Mailing address 11200 Briggs Court Anchorage, AK 99516 Site address Same Legal description (Sub'd., Block & Lot) Lake 0 The Hills, Block 3, Lot 2 Legal description (Township, Range & Section) Lot Size 54,458 Sq. Ft. Number of Bedrooms One (1) APPLICATION IS FOR: APPLICATION IS AN: TYPE OF DWELLING: (El all that apply) Absorption Field ❑X Initial �] Single Family (SF) Xl (w/wo ADU) Septic Tank ❑X Upgrade ❑ Duplex (D) n Holding Tank ❑ Renewal ❑ Multiple Dwellings ❑ Privy ❑ (SF and/or D) Private Well Water Storage n THIS APPLICATION INCLUDES A VARIANCE I WAIVER REQUEST FOR: Distance: I certify that the above information is correct. I further certify that this is in accordance with applicable Municipal Codes. (Signature of property owner or authorized agent) Permit/Rush Fees: EA — Waiver Fees: Date of Payment: q- ID'I' Date of Payment: Receipt Number: 000Sq3 Receipt Number: Permit No. 05P L$ t 3 -O Waiver No. Permit App_'-:- ::..c I`. GE ' ENGINEERING PO BOX 240773 ANCHORAGE,AK 99524 522-7773 677-7766(FAX) September 9, 2018 MOA Development Services Dept, On-Site Water&Wastewater Program 4700 Elmore Rd Anchorage, AK 99507 Subject: Lake 0 The Hills,Block 3,Lot 2– 11200 Briggs Court Septic System Design Dear On-Site Services Engineer: The owner of the above lot intends to construct a garage and possible ADU on the property. We are submitting this application for the construction of a new septic system to serve the facility. A system is currently in place and serves the five bedroom home on the lot. The attached site plan identifies the location of the home and the proposed garage along with the existing well and septic system. The proposed septic location and alternate site are also shown.No conflicts exist between this proposed system and any other well or septic system,whether on this lot or adjacent lots. The ground surface on the lot slopes moderately to the west. Ground contours and drainage arrows are shown on the site plan showing the grade and direction of flow. Storm water drainage will not impact this septic system. The new trench will be constructed parallel to the slope as much as possible. Wells on this and adjacent lots are shown. The new system will be a minimum of 100' from all wells and surface water, and more than 5' away from the septic tank. The alternate site is located more than 6' away. Please refer to the attached test hole log and plan and profile sheets for the septic design. If this design is followed,there will be no adverse impacts to adjacent properties. Sincerely, ' +'�������\\t Aw' Benjamin Schiller, PE *:49TH A\ I O —.jar— Benja hiller CE 12592 / ft Jr 9/9/18 `iVirePro sai00«. LAKE 0 THE HILLS B3 L2 ,---`\ '-. � --, ' N EXISTING SEPTIC SYSTEM EXISTING \\C '" SERVING HOUSE. ,' WELL \ 1 ''c ' \-_ / . 5 DRM HOME ) ) 1 v L . :. . ...-.,.... .N:::. ',...- ..:.---- - , --„---... ---\ , \, -- ---\ \--I, 1 V. :. • •. •-• . ,,, ' ..,:>. ,•,v i'( / (,_ \ ''C \.; • ,. . . \ ''' --A ,, -t--. \ , i .\\\-,, ...,.:, :. . . .___.\ \ \ , \ I i , --\ FCO ALTERNATE SITE 's`J n sv A► PROPOSED GARAGE • '`/v/���CCo• 1,000 GALLON TH-A MT'' SEPTIC TANK •LOT 2 CO • • • 15'LONG X 5'WIDE X 4' EFFECTIVE DEPTH • ABSORPTION TRENCH. • • LOT3 i / 10'UTILITY EASEMENT illG anEaw Eine+s NOTE: •�08*ir •lliI4 NO SLOPES>25%WITHIN 50'OR SURFACE WATER WITHIN 100'OF THE LEGEND �.` -\ ..•••.......... . PROPOSED SEPTIC SYSTEM ,:c- e,• ••. .� CO CLEANOUT °�. 49th •':*�t ALL WELLS ON SURROUNDING LOTS WITH IMPACTS TO THIS 2CO DOUBLE CLEANOUT ,, ; .h i FCO-FOUNDATION CLEANOUT :• •••• •••• i PROPERTY ARE SHOWN. NO CONFLICTS WITH WELLS OR SEPTIC i !'``'� '� �`�'"' SYSTEMS. FS-FLOW SPLITTER VALVE 11, 7,_ MICHAEL E. ANDERSON �� MH-MANHOLE .• --j,'s No. CE-4381 ,I:-.". 0 50 100 SLOPES>25% MT-MONITORING TUBE •. <4,p'0,••9-14-18 r.••''•e� FEET _SLOPES>46% SV-SEPTIC VENT .�4 jROFESS\�A��• TH-TEST HOLE • 1"=50' LAKE 0 THE HILLS, BLOCK 3, LOT 2 DESIGN FACTORS: SYSTEM REQUIREMENTS: 150 GPD PEAK FLOW 5' WIDE TRENCH SYSTEM PERK RATE: 1-5 MIN/IN 1,000-GAL SEPTIC TANK APPLICATION RATE: 1.2 GPD/SF 150 GPD/ 1.2 GPD/SF/ 5' WIDE .5 RED. FACTOR = 12.5 LF TRENCH REQUIRED (15 LF SPECIFIED) BOTTOM OF TRENCH: 7' BELOW GRADE FLOW LINE ELEVATION: 3' BELOW GRADE TOP OF TRENCH: .5' ABOVE GRADE r 6" T=Tf I I I= I F H I1E11III-111 1111 1 =111=III=111=III TI=1 2'-6" 111-1TT=1TT=UEl l 1 I 11 E111111-111=11 111 _.I I _11 .5..1171 6" ' #;# # # .; . ='=•'=•'=•'=•'=•= =•'='=•'=•'='='• 4" PERFORATED PVC (HOLES DOWN) DRAIN FIELD ROCK 0410. ) •INGIHGE ING TYPICAL WIDE TRENCH SECTION ...••�or"���,� (NO SCALE) .�(`P�.................•..•. •♦ NOTES: • 49th � ••••`: • 1. GRADE AREA OVER TRENCH TO DRAIN AWAY i� c -- 2. PROVIDE 3' OF COVER OVER TRENCHES AND 4' OVER SEPTIC TANK. OR 2' �•fi MICHAEL E ANDERSON i Virij ; WITH 2" OF INSULATION ♦c• NO. CE-4381 3. CHECK GROUNDWATER AT TIME OF CONSTRUCTION. IF LEVEL IS HIGHER •j'F,p'••.,9 14-18 ,,.•'•��.• THAN PREVIOUSLY OBSERVED, CALL ENGINEER IMMEDIATELY /44t PROFESSP:��• • ...7c _oiNa��\i,! MUNICIPALITY OF ANCHORAGE • '� F DEVELOPMENT SERVICES DEPARTMENT A G;.•••• ••\"-Y.! LI.700 ELMORE ROAD ANCHORAGE, AK 99519-6650 i ° 49th /�1 ° •!• • • • SOILS LOG AND PERCOLATION TEST ��,5; •MICHAEL E ANDERSON �; 4 . ..C• 4, No. CE-4381 .... l•A<4;0•'•..,9.14-180.•• cli LEGAL DESCRIPTION: LAKE 0 THE HILLS B3 L2 oii�pROF...�.�'�:•• PERFORMED FOR: RYAN CALLAWAY �-II1assus��4• DATE: 8/20/18 PROJECT No.: Professional Engineers Stamp: PARCEL ID#: 015-331-23 TECHNICIAN: J. MILLETTE DEPTH TEST HOLE A (feel) 1' OB SLOPE SITE PLAN 3 •.•e.i';!i-:i. : '•s• 5 : :', ::f:� SEE SITE PLAN 6 �:..i 7 •r.'` .:-,' " SANDY SILTY GRAVEL .`' GM/GW 8 ____.,.f-,•,-..,::_:;:-.,` : 9 %.:i:;..''`Y:::"..' 1 0 .r .` : WAS GROUND WATER ENCOUNTERED? NO .Si:=. '�'i:f!s:• • IF YES WHAT DEPTH? S I I "" DEPTH OF WATER AFTER MONITORING. NONE ! ' �•' DATE OF MONITORING. 8/27/;8 12 �;`.,f ... �.; =`��~ '. DEPTH TO ':�:::::.``:'' DATE READING GROSS TIME NET TIME WATER NET DROP 13 -:. (MINUTES) (MINUTES) (INCHES) •;•.....,.., (INCHES) 14 ::.''''y ': -` 8/27 TEST HOLE PRESOAKED PRIOR TO TESTING: 15 >".'-1•;.•�"• 1 1:00/1:10 10 ,z a 4 ' �'��`:'f:' 2 1:11/1:21 10 5'x/9 z 3 s BOH 3 1:22/1:32 10 516/816 3 s 17 4 1:33/1:43 10 5:1-i/8:4 3A 18 5 1:44/1:54 10 5i/8-11 3,s 19 6 1:55/2:05 10 5 q/8H 3,s 20- PERCOLATION RATE: 3.3 (MIN/INCH) PERC. HOLE DIA. 6 (INCHES) TEST RUN BETWEEN: 4 FT. and 5 FT. COMMENTS: IR�150, ;, 46%1\ jfrSeptic \ NN\4 , M „/ / ®•.BFB ® Brg a4 Y 52:9. 9 E �F � Well... ..7..15:157.::::7;,:'•. c1 a , • , ,...1„,. t •. CN 4'6 `•o. . • / ° CC/ CO 2 .. . o. . . . LEGEND SPOT ELEVATION -- DRAINAGE DIRECTION o--S\ 3 ....... c,o.,(1, , Q, k:,, , , co LOT SQ FOOTAGE 54,458 S.F. �� /, r0, N 49°1 7'54"W TOTAL LOT COVERAGE 5.66% /,h 68°r , 4-/77 _ 10.00' ,. 45"w�• ESMI. v �> GRAPHIC SCALE: 1 Inch = 50 Feet rMINI IMO NM= 25 12.5 0 12.5 25 50 100 A('s�\ Date Scale Legal Description 8/9/19 1" - 50' Lot 2 Block 3 Bobby F. Burnett RLS Grid PLOT PLAN 2941 Carriage Drive 2639 Lake 0'The Hills Anchorage, Alaska 99507 Drawn by Field Book Subdivision (907) 350-5541 BFB ASB2018 I hereby certify that the property described hereon has been surveyed +_``ik by me, or at my direction, and that the improvements situated thereon i OF AL are within the property lines and do not overlap or encroach on the / •N, . .,76 property lying adjacent thereto unless otherwise shown. That no 4' .efn 4 improvements on the property lying adjacent thereto encroach on the 167 � premises in question and that there are no roadways, transmission * 49 1 4-\ lines or other easements on said property except as shown. / j �J� 10• It is the responsibility of the owner or builder, prior to construction, / ,�.. •/ , d� / to verify proposed building grade relative to finish grade and utility BOBBY F. BURNEIR 1 ill connections and to determine the existence of any easements, covenants, LS-5464 or restrictions which do not appear on the recorded subdivision plat. + -g ." Ci . c3' 41 jr Listed distances prevail over scaling. ssIO1tAL Reproduction may cause distortion. \ '1116..Nh:40- f YVt'i1I v . - . i'' N '.44N\4 • d d d l� 4 d N d \• • S 4 • © •. ® BFB • 4 � Q'd e • d• .4 4 • • 4 L.-c) • <7 4 4 a o d4 • 400 .4 O .4 . . • d r. , • \1 d • 4 . 0 Li \� • O R / p • lA ° 4 • • a LEGEND 4• 5 `. •. SPOT ELEVATION •v ? / DRAINAGE DIRECTION 4 . 4 . d. �e-------- LOT SQ FOOTAGE 54,458 S.F. TOTAL LOT COVERAGE 5.66% Date Scale Legal Description 8/9/19 N.T.S. Lot 2 Block 3 Bobby F. Burnett RLS Grid PLOT PLAN 2941 Carriage Drive 2639 Lake 0'The Hills Anchorage, Alaska 99507 Drawn by Field Book Subdivision (907) 350-5541 BFB ASB2018 I hereby certify that the property described hereon has been surveyed 4 �� by me, or at my direction, and that the improvements situated thereon /' are within the property lines and do not overlap or encroach on the / <S� OF. property lying adjacent thereto unless otherwise shown. That no �'' improvements on the property lying adjacent thereto encroach on the —./ �1, i' , ,.7 h premises in question and that there are no roadways, transmission * 4 9 ' lines or other easements on said property except as shown. � / It is the responsibility of the owner or builder, prior to construction, , to verify proposed building grade relative to finish grade and utility (BOBBY F. BURNETT connections and to determine the existence of any easements, covenants, Y , LS'sass � or restrictions which do not appear on the recorded subdivision plat. /_�� 0, Listed distances prevail over scaling. Reproduction may cause distortion. `,4-„,-7-:/--;--.,0. ss,. AL .ar Municipality of Anchorage ;. Development Services Department Building Safety Division Onsite Water and Wastewater Program, 4700 S. Bragaw St. P.O. Box 196650 Anchorage, AK 99519-6650 Page of www cd.anchorage sk.us (907) 343-7904 ONSITE WASTEWATER DISPOSAL SYSTEM AND/OR WELL INSPECTION REPORT Permit Number: SWOR0026 PID Number: 015-331.23 Name UPERAL NATIONAL MORTGAGE Wastewater System: ❑ New ® Upgrade A�«a PO BOX 10284, VAN I ABSORPTION FIELD Plwne Nanper d Bebpana 5 ® Dep Tlarxh O Shalbw lr y D SW O Man° p Dlhw LEGAL DESCRIPTION Sol RMW9 T"De°"1`ai(xv"lllr ° 0.6 GPD/FI' 10 FI. lil k Lp &hovwwn Dep" W p" Oona" fan ong W greoe Gavel Cepa OWOWn ppe 3 2 LAKE O THE HILiS 3 Ft. 7 Ft TOWrnlnp Rarpe Se = Fe apese rwve onga papa GevW Lewh 128 Ft. 100 Ft. Well: ❑New ❑Upgrade GevW W.OaI Nuneel al a.aa OMaloe OalWaan Ma 2 Ft. 1 Fl DlaaullfSlKl1(P.M.. q e. C) T" Depth CaaeOro Tda ow" PS Pp Mal" Private-Existin FI. FI 1400 Ft' Sch 40 R D3031 CowDas OrWee sle Waa Level NWSIW Dae flNalsC Ft Ilfike Anderson 05/07/2008 Yrca pop sat Carow�e N+G, M TANK GPM FI. Fl SEPARATION DISTANCES ® Septic ❑ Holding ® S.T.E.P. ❑ Other. To Septic Absorption Un HoldingPublOprivaltua IT From Tank Field Station Tank ewer SLina Anchorage Tank 1250 GW v+.x 100'+ 100'+ 100'+ NA 25'+ M.laal NunOaa anpwManla Steel 2 &nape wWW 100'+ 100'+ 100'+ NA LIFT STATION La Law 5'+ ' 09+ 5'+ NA 500 Gal Orenco— Anchorage Tank FouMe an 5'+ 10'+ 5'+ NA M"P w level a drip a les W pn W.la W W m W 44" h 42" h 43" in Caton Dnn NA" 50'+ NA NA Pap M" a Modal EleC i mleappa°amee by Franklin 2445040 17-1/2h M11W1y •1%10A waiver issued "none known BENCH MARK Ofl'sitc absorption field and previous existing septic tank grin WWM Front door sill were abandoned in place per UPC. 100 FL Engineer's Stamp OF 4t4%11 Inspections performed by: ArcTerra Engineering R Surveying Dates: 'I st 5/3/08 * i4 2n0 Sn/as Development Services Department Approval • ' ': "' •"" «•:•«i Reviewed and approved by:Date: - /-5--I�j'� Kenneth •., cE/ to ' ��i FD mn I!") � .,,�//3• pB.• �Qlar WASTEWATER DISPOSAL SYSTEM DETAILS PID# 015-331-23 LAKE ❑' THE HILLS SUBDIVISION, L❑T2, BLOCK3 DISCONNECT LATTERAL! AT PROPERTY LINE & ABANDON IN PLACE AC=20.6' B— =27,5' A—D26.3' B—D= 6.1' A—E=6 •8' B—E=82' A—F=49.' 6) i OF ALgs PREPARED FOR, LNAME Gj�' '!'9 1� ADDRESS jol�• ; CITY, STATE PHONE H FUS : HELD BOOKS co~m. CE .' Wa / 6dm0Aar.BOUNpAgy DRAW RA �'��� $.•' !' AV STm" STAKING accxm CHE 1 ��i , T. I T DAM A giUFESSIOK= c„c• ML wo: GRII FILE " N': JOB Scales 1'= 20' PAGE 2 OF 3 //■�,+..11,11 t c vUl�� or o e.Vn sv �R• Nc YVSII.��b I WASTEWATER DISPOSAL TRENCH DETAILS LAKE ❑' THE HILLS SUBDIVISI❑N, L❑T2, BL❑CK3 4' MONITORING TUBE 4' MONITORING TUBE FROM SEPTIC lio TANK fU 100' I� PLAN VIEW DEEP TRENCH DETAILS SCALEI NTS TRENCH SECTION -TYPICAL 4' ICNImtm TUBO le "IN covER i� J J NOTEI BOTTOM OF SEWER DRAINROCK�O MUST BE 4+ FEET ABOVE GROUNDWATER AND 6+ FEET ABOVE BEDROCK. 1-211 1 PROFILE SECTION 35.0' OF A44 1 rKEN.449TE FfU US/ "A: Joe PJ�wESSIOT1A4 I SCALE:1'=10' PREPARED FOR: FEDERAL NATIONAL MORTG. PO BOX 10284 VAN NUYS, CA 91410-0284 FIELD BOOKS Ca MED.- spROARr. ORA"; k STAranc c9[arc0: KMD A7dllT: SCNULLER ND OAM010 a 10/11/06 CAM "IE cRto. NW105B A Mr. 06084.DWG '10B R"; 06-084 ------------- �DtSLLATION /a 01 Cam) —rILTER rAWIC �— 127' V/ 7y 114E SPACING DISTRIBTM LATERAL — r SEVER ROCK 0-5z '1. SCALEI NTS N O O O f` PAGE 3 OF 3 ` �RCTER� A ^ C, AS -BUILT SYSTEM DETAILS/SITE PLAN Permit SWO80026 LAKE ❑' THE HILLS SUBDIVISION, LOT2, BLOCK3 PID# 015-331-23 E 112TH AVE -------------- ----------- �r InT a B -F=79.3' I��t sAdW.�, OF ALS\ 1 LL ��ezl� W TE * +/ KENN FFUS: / / E- 16 / lisslON� FINAL GRADE SEWER ROCK 100• PREPARED FOR: FEDERAL NATIONAL MORTGAGE PO BOX 10284 VAN NUYS, CA 91410-0284 FIELD BOOKS rnuvNTM A -C=20.6' N A B -C=27.5' v A -D=26.3' C"ECKM: CHE B -D=36.1' ASBUILT A -E=61.8' 0r¢ ME B -E=82.8'-1258 GAL 588 A0A0 " STEP A -F=49.1' -SEPTIC TANK TANK B -F=79.3' I��t sAdW.�, OF ALS\ 1 LL ��ezl� W TE * +/ KENN FFUS: / / E- 16 / lisslON� FINAL GRADE SEWER ROCK 100• PREPARED FOR: FEDERAL NATIONAL MORTGAGE PO BOX 10284 VAN NUYS, CA 91410-0284 FIELD BOOKS rnuvNTM BOun fN N A ORAw: DR A STA"'M STAKING C"ECKM: CHE AfB "-' ASBUILT DATE, DAT 0r¢ ME cmo: GRI[ A0A0 " FILE Xe " : JOB I SCALE- V = 50' VM= r 75.2 n - SCALE, NTS rMANN.'1„\,fillIAR�W_Aal � Ak 9V511f�jb WELL & WASTEWATER DISP❑SAL SYSTEM DETAILS/SITE PLA LAKE O' THE HILLS SUBDIVISION, L❑T2, BL❑CK3 PID# 015-331-23 O --- - - - - - - - -- -L---- tr' ... E 112TH AVE -------------- ----------- - - - - T (E 117711 AVE) �-_ I�tt unTP.u� • � AI M1.iMrv1/.( • AXMW� M 14[( LOT 1 NO PUSLTC WELLS VMIM 20V OF PRa°OSED SYSTEM. NO PRIVATE WELLS VITHTN 200. OF PR SED SYSTEM EXCEPT AS NOTED. IXT SEPTIC SYSTEMS WITHIN 200• K PROPOSED WELL EXCEPT AS NOTED. OF AZ4' Aw �* 49� n*�, `KENNETH 1 .s CE 6 'k of "wESSlO1fAV ,/ RADII, QT LINES Scale, 1'= 100' DESIGN DETAILS PAGE 1 OF 3 5 BDRM X 150 GPD = 750 GPD 750 GPD/.0.6 GPD PER SO. FT. (17 MIN/IN.)= 1250 SQ. FT (1250 SF/ 2 X 7' GRAVEL) = 90 FT. TRENCH ADD 100' OF ADDITIONAL TRENCH - 100'+ (L) X 2' (W) X 7'(D) Total depth of system Is 10.0' from original grode. Total depth of gravel below distribution pipe Is 7' . NOTES, 1. INSTALL 1250 GAL SEPTIC TANK W/ 500 GAL STEP AND INSULATE TANKS IF <4' COVER. 2. INSULATE TRENCHES WITH 2' HD BURIAL FOAM IF <3' COVER 3. CONTRACTOR WILL ENSURE MINIMUM 27 SLOPE INTO SEPTIC TANK. 4. ADDITIONAL FILL WILL BE ADDED OVER SYSTEM TO ACHIEVE MIN. 3' COVER IF REQUIRED. 5. CONTRACTOR WILL ENSURE ALL SEPARATIONS TO ADJACENT WELLS 8 SEPTICS. PREPARED FOR, FEDERAL NATIONAL MORTGAGE PO BOX 10284 VAN NUYS, CA 91410-0284 FIELD BOOKS COMPUTED: ea»n - N A DR"""' DRAWN ST"101Q STAKING O1EO"a CHECKED ASDIKT. ASBUILT DATE' DATE 0"0. "IL OLD GRID ACRO PXE: FILE Axi "': JOB �R..U; oosl AST�A C' -:55P ;'F.01:ED'S ELECTRIC INC 272 459C -0:345139: P.1 inspection Heport Municipality of Anchorago, Building Safety Division 4700 Elmore Road INFO b HELP (9C7) 343.9211 INSPECTION: VOICE (907) 343.8300 - FAX (907)249.71/7 • www.muni.ory Name Gds Permit N 08.7928 Company ods Cie.^ Inspaction Date 09 -May -2008 AM Address I MU BRIGGS CT Phone 272-4591 Grid SW2M Subdivision i AKE O THE HILLS LOT 2 SK3 TR rva Work Description Sept Litt Station (1) Elect Opening Permit Technician SiNERO. PHYWS J. Comments or Directions septic Iln tail to meet inspection Type Eieciricametro Electrical Comments (for inspector use only) C , L- t F --I` �j'/i Ti v lel E E t� �t Z 1 C Inspector Dote '.S—`7 —tn�4_ � � -11. ENGINEERING AND SURVEYING, INC ��t► 'JW May 13, 2008 Municipality of Anchorage Development Services Department On -Site Water & Wastewater Program P.O. Box 196650 Anchorage, AK 99519-6650 Subject: SWO80026 Septic Upgrade — Lake O' The Hills, Block 3, Lot 2 Per previous design modification discussion with you, in lieu of the permitted 95' gravity -fed trench with 5.5' of effective, a pressurized 100' long trench with 7' of effective was installed with a 1250 -gallon septic tank and 500 -gallon lift station. Please see attached drawings. The hole spacing of the pressurized line was 30 total holes at 3.3' intervals. We do not expect there to be any adverse effect on adjacent lots by the development of this system. If you have any questions, please contact me at 868-3792 / FAX 868-3793. Respectfully submitted, AreTerra Engineering & Surveying, Inc. Attachments: MOA Inspection Report Septic System As -Built Electrician Inspection Report COSA Documents Modified Design Water Samples As -Built Survey MUNICIPALITY OF ANCHORAGE Development Services Department On -Site Water 8 Wastewater Program 4700 South Bragaw Street P.O. Box 196650, Anchorage, AK 99519-6650 (907) 343-7904 ON-SITE WASTEWATER DISPOSAL SYSTEM PERMIT Initial Permit Number: SWO80026 Legal Description: LAKE O THE HILLS BLK 3 LT 2 Design Engineer: 0070 ARC TERRA ENGINEERING & SU Owner Name: FEDERAL NATIONAL MORTGAGE Owner Address: PO BOX 10284 VAN NUYS , CA 91410-0284 Date Issued: Apr 07, 2008 Expiration Date: Apr 07, 2009 Parcel ID: 015-331-23 Site Address: 011200 BRIGGS CT Lot Size: 54458 SO. FT. Total Bedrooms: 5 Permit Bedrooms: 5 This permit is for the construction of: ❑✓ Disposal Field E Septic Tank ❑ Holding Tank ❑ Privy ❑ Private Well ❑ Water Storage All construction must be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal Code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72 ) and Drinking Water Regulations ( 18AAC80 ). 3, The engineer must notify DSD at least 2 hours prior to each inspection. Provide notification by calling (907) 343-7904 ( 24 hours). ( Not required for a Water Supply Permit only). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must be either: A. Open and closed on the same day. B. Covered, sealed, and heated to prevent freezing. Received Date: % Issued By. NC& Date: Municipality of Anchorage •a� Development Services Department Building Safety Division •`1'; Onsite Water and Wastewater Program ` 4700 South Elmore St. P.O. Box 196650 Anchorage, AK 99519-6650 www.ci.anchorage.ak.us (907)343-7904 ON-SITE SEWER/WELL SUBMITTAL COMMENT SHEET To• ArcTerra Legal description: Lake O'the Hills, B3 L2 ®Permit ❑C.O.S.A. ElInspection Report The attached paperwork has been reviewed and is being returned for the following reasons: 1. Show all easements for the lot. ov-2. The proposed trench location Is not parallel to the contours of the slope. Please change the orientation or provide a waiver request Including a cross-section of the trench that shows that the bottom will not encroach on the required separation distances and the effective area stays within the tested stratum. Waiver fee to be submitted. 0v.3. Any absorption systems with a design length greater than 50 feet shall be entered at the midpoint, unless otherwise approved. cK 4. Was a category III, nitrate reducing system considered for this lot? Name of reviewer. Deb Date: 414108 Please supply the necessary information and re -submit your request. LEAVE THIS FORM ATTACHED TO THE PAPERWORK Municipality of Anchorage • Development Services Department Building Safety Division On -Site Water and Wastewater Program 4700 Bragaw Street ' • 4 P.O. Box 196650 Anchorage, Alaska 99519-6650 www.muni.org/onsite (907)343-7904 ON-SITE SEWER/WELL PERMIT APPLICATION FOR A SINGLE FAMILY DWELLING Parcel I.D. 015-331-23 Property owner(s) Federal National Mortgage Day phone Mailing address PO Box 10284, Van Nuvs CA Zip Code 91410-0284 Site address 11200 Briggs Ct., Anchorage AK Zip Code 99516 Legal description (Sub'd., Block & Lot) Lake O' The Hills Block 3 Lot 2 Legal description (Township, Range & Section) Lot Size J`l,'i`J Sq. Ft. Number of Bedrooms 5 THIS APPLICATION IS FOR (® all that apply): THIS APPLICATION IS AN: Absorption Field El Initial El Tank 0 Upgrade ❑ Holding Tank ❑ Renewal ❑ Privy ❑ Private Well ❑ Water Storage ❑ I certify that the above information is correct. I further certify that this application is being made for a Single Family Dwelling and is in accordance with applicable Municipal Codes. (Signature of property owner or authorized Permit/Rush Fees: $460.00 Date of Payment: ev 02/c$ Receipt Number: 0 or (Rev. 11/05) Waiver Fees: $175.00 Date of Payment: Receipt Number: April 1, 2008 Municipality of Anchorage Development Services Department On -Site Water & Wastewater Program P.O. Box 196650 Anchorage, AK 99519-6650 Subject: Septic Upgrade — Lake O' The Hills, Block 3, Lot 2 Garness Engineering Group, Ltd (GEG) performed an adequacy test on December 5, 2007, which showed that the system exceeded the required absorption of 750 gpd. However, GEG had Chugach Sewer& Drain locate the field and it was discovered that a portion of the field was found to be off property (see attached GEG letter dated 12/21/07). Subsequently, the owner has requested we proceed forward to obtain a septic permit on the subject lot. Due to onsite conditions and the location and limited area of the existing and proposed upgrade, we are requesting a waiver to lot -line of 0' and a waiver to 35' of slopes greater than 25%. After suitable on-site conditions could not be located down gradient of the subject house, on March 25, 2008 one testhole was performed for the proposed system as shown on the attached design. Water was not encountered during the excavation or monitoring. The results of this soils test are attached. The general slope of this lot is from north to south at a grade of approximately 0-5% on the northern portion to a small break of 25%+ and then continuing southwestward at 10%+/-. We have designed our system utilizing the existing testhole that was excavated for the existing 5 -bedroom house. The lot is served by an individual well, located on the northeastern portion of the lot. After discussions with your office, we propose to disconnect the existing laterals at property and abandon in place that portion of the system, which is off property. The existing system on property will be augmented by installing an additional 95'+ of trench. Water was not encountered during the excavation or monitoring. LAKE O' THE HILLS, BLOCK 3, LOT 2 April 1, 2008 Page 2 of 2 There are no public or private wells within 200' of our proposed system location except as noted. There is no surface water within 100' of the proposed system and there are no known curtain drains within 50'. According to the recent GEG adequacy test and visual observations --the existing system has been functioning properly with no evidence of day lighting effluent. We do not expect there to be any adverse effect on adjacent lots by the development of this system or the granting of the requested waivers. If you have any questions, please contact me at 868-3792 / FAX 868-3793. Respectfully submitted, ArcTerra Engineering & Surveying, Inc. Attachments: On -Site Well and Sewer Application Wastewater Absorption System Details/Site Plan Soils Log/Percolation Test Owner/Contractor Specs GEG Letter 20441 I" rARNIIGAY BLVD • EAGLE RIVER, AK 99577-8736 • I'll (907) 868-3791 • FAX (907) 868-3793 WELL & WASTEWATER DISPOSAL SYSTEM DETAILS/SITE PLA LAKE ❑' THE HILLS SUBDIVISION, LOT2, BLOCK3 PID# 015-331-23 O PY •�---------- E 112TH (EiurN • AWNq'w w AAQ LOT 1 NO PUBLIC nLS WITHIN YOD• or PROPOSED SYSTEM. NO PRIVATE WELLS WITHIN 2W Or PROPOSED SYSTEM EXCEPT AS NOTCD NO SEPTIC SYSTEM WITHIN EDD• OF PROPOSED WELL EXCEPT AS NOTE& •: `�`�. °F... 1 * 49 x ., . *+, KEN�HFUS 16 16 �FesstoN�� � LOT 2 BLOCK 3 C" i ALL RADII, TENTS & T LINES TO CONST UCTInKI Scale: 1'= in, DESIGN DETAILS PAGE 1 OF 3 5 BDRM X 150 GPD = 750 GPD 750 GPD/.0.6 GPD PER SO. FT. (17 MIN/IN.)= 1250 SQ. FT (1250 SF/ 2 X 5.5' GRAVEL) = 114 FT. TRENCH ADD 95'+ OF ADDITIONAL TRENCH - 115'+ (L) X 2' (W) X 5.5'(D) Total depth of system is 14.0' from original grade. Total depth OF gravel below distribution pipe is 5.5' . NOTES: I. INSTALL 1500 GAL SEPTIC TANK AND INSULATE TANK IF <4' COVER. 2. INSULATE TRENCHES WITH 2' HD BURIAL FOAM IF 0' COVER 3. CONTRACTOR WILL ENSURE MINIMUM 2% SLOPE INTO SEPTIC TANK. 4. ADDITIONAL FILL WILL BE ADDED OVER SYSTEM TO ACHIEVE MIN. 3' COVER IF REQUIRED. 5. CONTRACTOR WILL ENSURE ALL SEPARATIONS TO ADJACENT WELLS 6 SEPTICS. PREPARED FOR: FEDERAL NATIONAL MORTGAGEF �,�tCTEgo PO BOX 10284 a �`9 VAN NUYS, CA 91410-0284 `4 �LLnn`L_\_\\\ '`�� FIELD BOOKS souNDAR��F srA'wc STAKIp . A �l DMC F& AO1O FEE: FILE COWITEa CRAW"` DRI O'Eoca" CHE DATL' DA �a'°�C'RRI1 Joe NR: JOB A a4Ao sub' r0 It,( At "'11-11j16 WASTEWATER DISP❑SAL SYSTEM DETAILS LAKE ❑' THE HILLS SUBDIVISION, LOT2, BLOCK3 PIDy 015-331-23 DISCONNECT LATTERAL`. AT PROPERTY LINE 4 & ABANDON IN PLACE A C=23.3' B- A -D 27.2' B -D= 7.4' A -E=4 .3' B -E=59 ' A -F=50. A -G=29.8' B -G=56.3' ALgS 1 PREPARED FOR: � ��NAME T * ADDRE H STATE PHONE KENN U. D FlELD BOOKS m.wrm: `� C 9118 .'�� / eaK�oAxr. N A puwr. RA S �`� .s/� d8 .ee2� sruwc STAKING °EOE"' CHE ��a�NV =� uwr rrt ASBUI DATE...- AT GRI( ecAo nr: FILE '0B "" JOB Scale: 1'= 20' PAGE 2 OF 3 llii']��Ilill U G SND yNa'' e' �F4 AK 9931++++� WASTEWATER DISPOSAL TRENCH DETAILS LAKE 0' THE HILLS SUBDIVISION, LOT2, BLOCK3 4' MONITORING INSTALL TUBE CLEANOUT 4' MONITORING TUBE FROM SEPTIC • TANK • 4 c fL I 95'+ I PLAN VIEW DEEP TRENCH DETAILS SCALE NTS TRENCH SECTION -TYPICAL /—.• CLEANOUT.' MONITOIING NKA --DRIGINK COAK 0-5i i� J NOTE, BOTTOM OF SEVER DRAINROCK Vit» MUST BE 4+ FEET ABOVE GROUNDWATER AND 6+ FEET ABOVE o4 BEDROCK. PROFILE SECTION lZi to-ts� i OF. AZ...... 4, Id -49 II �' KEN N. D US C 8 "'1 35.0' IF "IN COVER ------------- I INUXATIOF (IF 47 COVER) �M ER FAIRIC � V PERF DISTRIVIDN LATERAL -?!' SEVEN ROD( F -- 0-5% ORIGINAL GRADE 0-5% SCALE:1'=10' PREPARED FOR: FEDERAL NATIONAL MORTC. PO BOX 10284 VAN NUYS. CA 91410-0284 FIELD BOOKS cONRllmc ROS mr. DRAw' km STMR O(«EO: KMD AS& J, SCNUL R NO DAIE'10 4 06 10 1 06 DRG ME ERO NW105B 4M RE' 06064.BRc JOB "" 06-084 S .n Iri T SCALE, NTS PAGE 3 OF 3 �p.".Al 44ND 5110 L'� Il4 AS 99311-1116 • • . . ENGINEERING AND SURVEYING, INC SOILS PERCOLATION TEST Performed for. Bob Brock Date Performed: 03 25 08 Pmjcct�Pth LAKE O' THF HILIS S III nr•r; z LOT 2 TEST f10LF, 0 T1108-1 ORG/OL SEE ATTACHED SITE PLAN FOR HOLE LOCATION Was Ground water encountered? NO What depth? NA SM/ml —frost top 3' Depth to water after monitoring? NO Date? 04/01/08 1, Kenneth M. Duffus, certify that this test vas performed in accordance with all State and Municipal guidelines in effect on this date. Reading Date Gross Net Depth to Net Time Time Water Dro 1 3/26/08 1:00 6" CM/sm w/somegp/sw 2 1:30 30 min 4 5/16" 1 11/16" & boulders to 2' 3 + 1:31 6" 4 2:01 30 min 4 6/16" 1 10/16" 5 " 2:02 6" 6 2:32 30 min 4 5/16" 1 11/16" 7 8 9 10 1 12 OLE PRESOAKED + Water Added RIOR TO TEST Percolation Rate 17.77 (mien) Pere Hole Diameter 6" ,0.11. Test Run Betneen _— feet and _ 7 feet 1, Kenneth M. Duffus, certify that this test vas performed in accordance with all State and Municipal guidelines in effect on this date. Municipality of Anchorage Development Services Department Building Safety Division On -Site Water and Wastewater Program 4700 Bragaw Street P.O. Box 196650 Anchorage, AK 99519.6650 www.ci.anchoragc.ak.us (907)343-7904 Waiver Review Worksheet WR#:080017 PID#:015-331-23 HA/Pennit# SW080026 Date Received: April 7, 2008 Legal Description: Lake O'The Hills, Block 3 L2 Engineer: Kenneth M. Duffus, P.E. KND Engineering, Inc 20441 Ptarmigan Blvd. Eagle River, AK 99577 Applicant: Federal National Mortgage Waiver Requested: 0' lot line waiver. Criteria: Geology A. Water Table B. Soil Sorption C. Permeability D. Water Table Gradient E. Horizontal Separation Points: Total: .......................................................................... Waiver Is Granted: X Waiver Is not Granted: List Conditions or Reasons for above: Date: 417108 By: Deb Wock nfus [......................................... Revie:::.................. Rec#: 106611 Amount: $175 Date Paid: 4r712008 Municipalit,3T of Anchorage CO. IkA 10t167A) - Awhomge, Alask, 5r.A519-6650.47001:7111ire Rwd Oaim(9(17)M.Mo 1 • rac:(907);i1$dt-^0(1 ala#or Dlark Ilegicll DcvcloPn1c11t, Scniccs Dcptu-(nlcnl April 7,2008 Kenneth Iii. Duffus, P.E. KND Engineering, Inc 20441 Ptarmigan Blvd. Eagle River, AK 99577 Subject: Waiver Request for Lake O'The hills, Block 3 L2 Waiver Request WR#: 080017 Parcel ID # 015-331-23 SW080026 Dear Kenneth M. Duffus, P.E.: �qT'tnPnt S `` e c 1 Department Your request for a waiver of the required 10 feet horizontal separation from the absorption field to the propertyline has been approved. The approved separation distance is 0.0 feet. This waiver approval applies to the existing absorption field to property line separation only. Any future upgrade to the on-site wastewater disposal system will require all separation distances be met or another approval from this department. If there are any further concerns or questions regarding this waiver, please call our office at 343-7904. Sincerely, u'W Deb Wockenfuss Civil Engineer On -Site Water & Wastewater Program C01717111171ity, Security, Prosperity GARNESS ENGINEERING GROUP, Ltd. CONSULTANTS S GENERAL CONTRACTORS i ___!id. December 21, 2007 Paul Brannon c/o 311 I C Street Anchorage, AK 99503 Attn. Bob Brock REFERENCE: Lake O The Hills; Lot 2 Block 3; 11200 Briggs Court: Well and Septic System Evaluation, and Upgrade Proposal for a Septic System Serving a Single Family Residence within the Municipality of Anchorage (MOA). To whom it may concern, for Per the request of your agent, we inspected the well and septic system, which serve your property were performed onose of 12/4/2007an M02/S/2200007, andCate of Onsite 12/18/2007. Our findinstems gs are sum Site visits follows: 8 summarized as WELL: On the day of our test (12/4/2007) the static water level was 171 feet below the top of the casing. Six hundred and ninety (690) gallons were pumped from the well at an average flow rate of 5.75 gallons per minute (GPM) which resulted in no drawdown. Based upon this data, it can be concluded that the well will continuously produce at least 5.75 gallons per minuteexcee the Municipal requirements for a 5 bedroom house (.52 gallons per minute). , ds WATER QUALITY: Water quality samples were taken for arsenic, nitrates and coliform bacteria and sent to a state certified laboratory to be analyzed SEPTIC SYS : Per MOA records, of a 15allonn sesethe septic system was installed on 10/3/1980. It consists 00 gptic tank and a deep trench type drainfield that is a 3.3 foot wide, 106 feet long, and has an effective depth of 5.5 feet. Prior to starting the adequacy test on 12/4/2007, the dminfield had 5 inches of liquid in the monitoring tube. After pumping the septic tank, a total he 1560 gallons of water was added to the dminfield through the cleanout, which caused a rise of 1of 7 inches in the monitoring tube. The dminfield was checked 840 minutes later and the liquid level had not dropped. Prior to starting the adequacy test on 12/5/2007, the dminfield had Ili inches of liquid in the monitoring tube. A total of 790 gallons of water was added to the dminfield through the cleanout, which did not cause a rise in the monitoring tube. Based upon this data, it was determined that the absorption rate of the trench exceeds 750 gallons per day, as required for a 5 bedroom residence. Upon reviewing the as -built survey and the MOA septic records, we suspected that the drainfield may be partially off the property. We had the lot lines marked be a professional land surveyor. On 12/18/2007, Chugach Sewer and Drain ran a transmitter down the septic system to figure out exactly where the dminfield is. We discovered that the dminfield is twenty-five to thirty feet off the property. Based upon our assessment, the dminfield will need to be abandoned, and a new system installed before you can transfer title (sell) the property. The following is a summary of the engineering costs associated with upgrading the septic system. - 3701 E. Tudor Road, Suite 101 • Anchorage, Alaska 99507.1259 Ph: (907) 337-6179 0 Fax: (907) 338-3246 • Wcbsite: www.garnessengincering.com es to te or the evaluation, septi ctankfPumping, elChflow tes% services, quality S ands, pm -soak, septic report: S2,356.00 preparation of this • Engineering services to perform soils evaluation and percolation test: one perk test, S250.00• for each additional perk test. S500.00• for • Excavator to dig test holes with rubber fire backhoe: $550.00 for one and S250.00 for each additional test hole. • Engineering services to design the septic system: 5700.00•. This is based upon a conventional gravity (low septic system with no waivers to property lines, surface waters, or nearby wells. • M.O.A. sewer upgrade permit: 5460.00• Payable to the M.O.A. • Engineering services to inspect the installation of the septic system and preps �_ built drawings. Assuming a conventional gravity flow septic system with a single standard r and no sand filter: $800.00. Upon request, we can provide you with our standard rate sheet which lists the inspection costs for other types or configurations of septic systems. This information is also available on gaour website at m essengineering.com. If an alternative technology septic system is required, such as a Quanics Aerocell treatment unit, the design and inspection costs will be an additional $500.00. The Items marked with an asterisk must be paid prior to submitting the design package to the Alunicipality of Anchorage. For your convenience, we accept all major credit cards. The cost for the excavator to perform the installation is unknown at this time. After the soils testing and design have been completed, we will provide you with a bid for the septic installation. completion Systems App ovaland deliver it to th oPaperwork installationf the will eoMAGEG prepare MOA Certificate of Onsite $150.00). The MOA will charge $430.00 to process the COSA. preparation/delivery fee of If you have any questions, please contact us at 337-6179. For more extensive information on septic system testing and design, see our website at wwlv.garnessengineering.com. a i look forward to assisting you with your engineering needs, and will do our best to provide a cost A.S. 371 Ph: (907) 337-6179 • Fax: (907) 338-3246 • lvebs te: www.garnessengineering.com - i A(TERRA ENGINEERING AND SURVEYING, INC. ON-SITE WASTEWATER DISPOSAL SYSTEM CONSTRUCTION PRACTICES AND MATERIAL SPECIFICATIONS LEGAL DESCRIPTION: LAKE O' THE HILLS, BLOCK 3, LOT 2 GENERAL: 1. The scope of this project includes the installation of a septic tank and/or drainfield to serve a single-family residence on the referenced property as delineated on the attached Municipality of Anchorage (MOA) permit and site plan. Construction shall be in accordance with the approved site plan and design drawings; MOA permit with any special provisions or conditions, and all applicable State and Municipal Wastewater Disposal Regulations. 2. ArcTerra Engineering & Surveying, Inc. (ArcTerra) assumes no responsibility of the accuracy of the as -built survey provided by the owner or owner's representative. 3. The owner or contractor is responsible to notify the engineer of any discrepancies noted on the design plans or drawings prior to commencing work. These discrepancies could be, but not limited to, possible encroachments, surface water, varying soils, unplatted easements, types or use of dwellings on or adjacent to property, nearby public wells, etc. 4. The contractor shall be responsible for locating any necessary underground utilities, easements, property lines and surface water. The owner and/or contractor shall ensure, if deemed appropriate, that a registered land surveyor prior to construction flags all setbacks. The contractor shall be responsible for verifying allpertinent separation distances and component layout. S. Unless specifically agreed otherwise, the property owner shall be responsible for final grading areas subsequently depressed from soil settling. On all leachfield mound systems, the property owner shall be responsible for ensuring a satisfactory vegetation growth over the mounded area. 6. The MOA Development Services Department On -Site Water & Wastewater Program must certify contractors installing wastewater disposal systems. Owners installing their own systems must also receive prior approval from said MOA Department. SEPTIC TANK / HOLDING TANK / LIFT STATION INSTALLATION: 1. A septic tank is to be constructed by a certified septic tank manufacturer. eanouts 2. ThConstruction s septic tank shall be suf c entlyclbedded with p opergmaterial and compacting to prevent damaging, settling or shifting of the tank. 3. All standpipes on the septic tank shall extend a minimum of 12 inches above the final grade. 4. Septic tanks installed with less than 4 foot of cover shall be insulated. The contractor will ensure that the fill over the tank does not exceed the burial depth rating. 5. A foundation cleanout shall be installed one to four feet from the building foundation. In the line between the tank and the leachfield there shall be two LAKE O' THE 11ILLS B3, L2 April 1, 2008 Page 2 of 3 adjacent cleanouts (unless an effluent pumping system exists within the septic tank). These cleanouts shall be located on undisturbed soil not more than 10 feet from the tank. The second cleanout, in line, shall be to clean toward the septic tank. 6. Finalgrading over the septic tank shall be such that a positive slope exists away from the septic tank. 7. All H.D.P.E. tanks shall have a vertical length of 4 -inch perforated drainpipe besides the tank extending to the bottom of the tank to above grade to monitor ground water. 8. All tanks shall be anchored when there is not enough adequate soil cover to resist buoyancy forces in high -groundwater areas. 9. All holding tanks and lift stations shall have an audible and visual alarm inside the residence. 10. All lift stations shall be wired in compliance with the Uniform Electrical Code and all MOA guidelines. 11. The contractor shall remove the old tank, or abandon it in compliance with the Uniform Plumbing Code. The contractor is solely responsible for the abandonment procedure. ABSORPTION TRENCH/DRAINFIELD INSTALLATION: I. Excavate the proposed trench to the dimensions shown on the design. The bottom of the excavation shall be within 2 inches of level. If the sidewalls of the excavaction become smeared, they must be raked or scratched (roughed -up) beforegravel (sewer rock) placement. 2. Once the sewer rock is installed, the distribution pipe is installed level with the perforations facing downward. Gravel is then to be placed over the distribution pipe to provide a minimum of 2 inches of cover over thepip. 3. A silt barrier must be installed between the final gravel layeer and the native soil backfill. Ensure the silt barrier covers the entire gravel surface before placing backfill. 4. Monitoring tubes shall be four- (4) inch diameter, installed approximately in the locations shown on the design, and extend a minimum of 12 inches above final grade. The portion of the monitoring tube extending through the gravel shall be perforated from the bottom of the trench to the invert of the distribution pipe. This is equivalent to the effective depth of the gravel as noted on the design. 5. Backfill over the final gravel layer must not be less than twenty-four inches. Insulation must be installed when the backfill depth is less than thirty-six (36) inches. The finish grade over the trench must be mounded to prevent the formation of a depression after settling. 6. All advanced technology waste water disposal systems (Advantex, Biocycle, Intermittent Dosing Sand Filter, etc...) shall be constructed, installed, maintained and monitored per manufacturer's specifications and MOA requirements. MINIMUM MATERIAL SPECIFICATIONS: 1. A MOA approved septic tank manufacturer must construct any septic tank proposed for installation. 2. The following pipe materials are MOA approved for use in septic system installations: Type of Pipe Yes rat d olid Cast Iron Yes ASTM D3034 (PVC) Yes Yes ASTM F810 (HDPE) Yes No ASTM D2662 (ABS) Yes Yes 204-11 PTARMIGAN BLVD • EAGLE RIVER, AK 99577.8736 • PH (907) 868-3791 • FAX (907) 868.3793 LAKE O' TtIE }TILLS B3, L2 April 1, 2008 Page 3 of 3 3. Insulation shall be at least 2" thick extruded direct burial polystyrene (Dow Chemical Company Styrofoam HI or equal). 4. Septic tank inlets and outlets shall be fitted with watertight couplings (Caulder, Fernco, or equal). S. A permeable nontoxic silt barrier (Typar 3401, Mirafi 140N, or equal) must be installed between the final leachfield gravel layer and the native soil backfill. 6. All leachfield gravel (sewer rock) shall be 0.5"-2.5" screened gravel with less than 3% passing the #200 sieve. If deemed necessary, a sieve analysis should be performed. 7. When sand is being used as a filter material, its gradation specification must conform to current MOA or ADEC requirements. INSPECTIONS: Typically there will be three (3) inspections required during the installation of the wastewater disposal system. These inspections will occur as follows: 1. The first inspection must be conducted after the excavation of ditches, pits, trenches, or beds and before the installation of any gravel. A septic tank may be set in place, but may not be backfilled before this inspection. 2. The second inspection must be conducted after the placement of the sewer rock, distribution lines, standpipes, and cleanouts, but before the placement of the silt barrier, insulation, or any other backfill. 3. The final inspection is to occur upon final grading of the property. Often there will be more than these 3 inspections required, especially with the installation of multiple trenches, sand filters, pressurized distribution systems, etc. The inspecting engineer is to be contacted at least 24 hours prior to the start of construction. If necessary, a pre -construction meeting will take place on-site. The inspecting engineer will not coordinate, direct or control in any way the contractor's activities. The owner shall contract with the contractor to perform the work outlined in these specifications and attached plans and in accordance with the attached MOA permit. All materials, components, and construction practices shall comply with the MOA's and the State of Alaska's latest ordinances, regulations, or policies regarding wells and septic systems. The failure of the inspecting engineer to notice a material or construction non- compliance does not relieve the contractor of his/her responsibility to correct such deficiency. There will be no contractual arrangement existing between the contractor and ArcTerra. ArcTerra shall be the owners representative and will inspect the work as stated above to document the contractor's activities. Final acceptance of the contractor's work rests with the owner and the MOA. ArcTerra shall have no liability to the owner or to others for acts or omissions of the contractor or any other persons performing work on this project or the failure of the contractor to carry out the work in accordance with these construction documents. ArcTerra's inspecting engineer will not be responsible for the construction means, methods, and techniques, sequence, procedures or the safety precautions incident to this project. BY PROCEEDING FORWARD WITH THE INSTALLATION OF THE WATER AND/OR WASTEWATER SYSTEM (S), THE PROPERTY OWNER, CONTRACTOR AND WELL DRILLER ACKNOWLEDGE HAVING READ AND ACCEPTED THES, E SPECIFICATIONS. - - 20411 PTARMIGAN BLVD • EAGLE RIVER, AK 99577-8736 • PI I (907) 868-3791 • FAX (907) 868.3793 e ~,. ~J MUNICIPALITY OF ANCHORAGE ', ~ DEPARTMENT OF HEALTH & ENVIRONMENTAL PROTECTION ENVIRONMENTAL ENGINEERING DIVISION 825 L Street - Anchorage, Alaska 99501 Telephone 264-4720 ON-SITE SEWAGE DISPOSAL SYSTEM AND/OR WELL INSPECTION REPORT NAME ]PHONE J [i~ NEW MAILING/AD,ESS ~ L~G~D ESCRIPTION, ~ ~ ~ LOCATION ~ . ~ NO. OF BEDROOMS ~ W~ll Absorption area Dwelling PERMIT NO. DISTANCE TO: ] ~ O O ' I ~ ~' ~O ~ ~ Z Manufacturer ~ Material - No. o~compartments ~ Liq. capacit~ i~s IF HOMEMADE: Inside length ~ Width ~ Liquid dept~ ~ ~ DISTA~ TO: / Well Dwelling PERMIT NO. ~_~O Z ~ M~urer~ ~ ~d capa~i~alJons D Well Foundation Nearest lot line PERMIT NO.~ ~; DISTANCE TO: ~[O~ ~ ~ ~ ~/~ ~z No. oflines~ ~e~ ~1~IU~ ~HOnches ~ Top of tile to finishs7 , Material beneath tile a ~ ~~s ~ ~'~ Total effective ab~orp~ion[z~(~area Length Width Depth PERMIT NO. < ~ Type of crib Crib diameter Crib depth Total effective absorption area ~ Well Building foundation Nearest lot line ~ DISTANCE TO: ~ ~ss ~ .., ~ Depth Driller Distance to lot line PERMIT NO. ~ Building foundation Sewer line Septic tank Absorption area(s) ~ DISTANCE TO: OTHER PIPE MATERIALS SOILTEST ~ATliN~u [0 I 4'~n INST~ER , R EMAR KS ) 72-013 (I . 3/78) F'EF:M I T NO. RPPLICRNT WILL-RSKR CONST. 999 ER=,T TUDOR ~202: LOCATION BR IGG~NST. (~Y A. LEGRL LOT t BLK :,-' LRKE 8 THE HILL LOT _,I~E'= ~ __ _~=,lEfl IS: TRENCH TYPE OF qnZL RBSORPTION ~'"-' DEPRRTMENT 0'" HERLTH RND EN'v'IRONMENTRL F~'OTEC:TIOI'.,t?.~~' (J'~.~L~L .... , _ ..... .. ,_,_, ,: .... E ..... TF..EET., RNUHORRL~E., RF .... ~L4~_, & 27¢';-'?.~7.~ MR,,-~II',I_M NLIMBER OF BEDROOMS = 5 SOIL RRTII'.,IG ("-';.] FT,.."BR)= 225 THE RE&~UIRE[.', SIZE nF THE SOIL RBSCR. PTInN SYSTEM IS: / //LP; . ~ /" /.b"' [:.EPTIq "_~. 5 #....E[-.~ _'~TH= :.-LEi----": ,3F:R"...'EL ~;.EF"TH= ._'"~-.. 5 THE LENGTH DIMENSION IS THE LENGTH (IN FEET) OF THE TRENCH OR DRRINFIELD. THE DEPTH OF R TRENCH OR PIT IS THE DISTRNCE BETWEEN THE SURFRCE OF THE GROUND RND THE BOTTOM OF THE EXCRVRTION (IN FEET). THERE IS NO SET WIDTH FOR TRENCHES. THE GRRVEL DEPTH IS THE MINIMUM DEPTH OF GRRVEL BETWEEN THE OUTFRLL PIPE RND THE BOTTOM OF THE EXCRVRTION (IN FEET). REC--.~Ln ][ F-:E[-TM SEF"T I 6: T:]~'"~:: S I ZE:= 15~Z~8 ,=~LLL :: PERMIT RPPLICRNT HRS THE REz, FONz, IBILIT~ TO INFORM THIS [:,EPRRTMENT [,I_IRING THE iF~STRLLRTION INSPECTIONS OF RNY WELLS RDJRCENT TO THIS F'ROPERTY RND THE 'NUMBER OF REz, I[.,ENE. E=, THRT THE WELL WILL SERVE. ,-' ',- '- ' " -I . HI=, E~RCKFILLING OF RNY m~:TEH WITHOLIT FINRL IN:,FEL. TILN RND RPPRO"/RL BY T '- DEPRRTMENT WILl_ BE SLIBJEC:T TO F'ROSEC_TI~N. MINIMUM DISTRNCE BETWEEN R WELL RND RNY ON-SITE SEWRGE DISPOSAL SYSTEM-IS ±00 FEET FOR R PRIVRTE WELL OR ~50 TO 200 FEET FROM R PUBLIC WELL DEPENDING UPON THE TYPE OF PUBLIC WELL. MINIMUM DISTRNCE FROM R PRIVRTE WELL TO R PRIVRTE SEWER LINE IS 25 FEEl" RND TO R COMMUNITY SEWER LINE IS 75 FEET. OTHER REQUIREMENTS MRY RPPLY. SPECIFICRTIONS BND CONSTRUCTION DIRGRRMS RRE RVRILRBLE TO INSURE PROPER INSTRLLRTION. PEF:f"I T T E.---.F I F..:ES [:,EC:EI"IE:ER 2~::1.., I CERTIFY THRT ±: I RM FRMILIRR WITH THE REQUIREMENTS FOR ON-SITE SEWERS RND WELLS RS SET FORTH BY THE MUNICIPRLITY OF RNCHORRGE. 2: I WILL INSTRLL THE SYSTEM IN RCCORDRNCE WITH THE CODES. ~: I UNDERSTRND THBT THE ON-SITE SEWER SYSTEM MRY REQUIRE ENLRRGEMENT IF THE RESIDENCE IS REMODELED TO INCLUDE MORE THRN 5 BEDROOMS. S I GNED: RF'F'L I CFtNT WI LL-RSKFI CONST: ISSUED - ,RTE L¢-___ V4. 0 }JILL ~ ~ BO~.TC~ OF ~h~ EN~:~RT](~'~ (IN MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH AND ENVIRONMENTAL PROTECTION Pouch 6-650, Anchorage, Alaska 99502 276-222~ SOILS LOG- PERCOLATION TEST [] SOILS LOG PERCOLATION TEST PERFORMED FOR: LEGAL DEScRIPtIoN: 1 2 3 4 5 7 8 ~0 ~2 ~3 14 2O Ci~*~MM E NTS PERFORMED BY: 72-0013 (7/76) Earthwork Inc. DATEPERFORMED: 9-15-80' Lot~ Blk3, Lake of the Hills Subdivision TOPSOIL Brown SILT with SILT (30%) w/Trace of Cobbles & Occasional Boulder SLOPE SITE PLAN · , ' -- I ~J i.-,-~a WAS GROUND WATER ENCOUNTERED? IF YES, AT WHAT DEPTH? NO' B.O.H. 13.5' NO BEDROCK Gross Net Depth to Net Reading Date Time Time Water Drop I 9-15-80 0 0 9" :, 2" ', 7 " 30 30 11 5~8" 2 5/8" 8 " 40 10 12 1/8" 1/2" ~ " 50 10 12 1/2" 3/8" lc, " 60 10 13" 1/2" PERCOLATION RATE 22 _ ,,,.,,,~"~ ~,(,~.n u t e s / i n c h ) .., TE:. - ~ -. *- ~,~$ W.J. TH~PSON' · ~ September 18, 1980 R&M No. 051001-72 Earthwork Inc. Post Office Box 2281 Anchorage, Alaska 99510 Attention: Mr. Gary Fredrick Re: Subsurface Investigation for On-Site Septic System; Lot/t~ Block 3, Lake of the Hills Subdivision ~ Dear Gary: At your request on September 15, 1980, R&M Consultants, Inc. conducted a subsurface soils investigation at the proposed location of the sanitary sewer drain field for the subject lot. The test procedure complied with those required by the Municipality of Anchorage. The site topography is gently sloping to the west and south at the test location. At the time of the investigation the site had been cleared of native vegetation. Field activities were performed on September 15, 1980. Excavation was accomplished with a backhoe supplied by Earthwork Inc. The test hole were sited according to your instructions and the approximate location is shown on the attached soil log. The subsurface soils were inspected at the time of excavation by Pete Herstek a technician from our office. Grab samples were taken to the labor- atory and were visually classified. The description of the soil encountered is shown on attached soils log. No bedrock was encountered to the depth excavated. At the time the test hole was excavated seasonal frost was not present and permafrost was not encountered. No ground water table was encountered at the time of the inspection. It should be noted that the information given in this report displays specific conditions encountered on the date of the investigation. Subsurface condi- tions may vary on other parts of the lot without any apparent superfical evidence of the change. Groundwater level may fluctuate both seasonally and from year to year. ANCHORAGE FAIRBANKS JUNEAU VALDeZ ~VASILLA 'Mr. Gary Fredrick September 18; 1980 Page 2 A percolation test was oerformed at the depth indicated on the soils log below the ground surface. The average infiltration in the stratum tested was measured over sixty (60) minutes. The measured percolation rate over the last thirty (30) minutes was 22.0 minutes per inch. We appreciated this opportunity to be of service to you. Please contact us if you have any questions concerning this letter or if we can be of additional service. Very truly yours, R&M CONSULTANTS, INC. William d. Thompson, P.E. Senior Engineer Enclosures WJT//jdu F R O M SUBJECT MESSAGE DATE SIGNED REPLY I~edifprm® 4S 472 SIGNED SL~ID PARTS I AND 3 WITH CARBON INTACT - D&Bt q IA/III IJl~ DATE // oGREI~....,R ANCHORAGE AREA BOR~ Department of Environmental Quality 3330 C Street Anchorage, Alaska 99503 INSPECTION REPORT ON-SITE SEWAGE DISPOSAL SYSTEM NAME GQU' LOCATION MAILING ADDRESS t 7d ¢ ~ $'~'~ LEGAL DESCRIPTION ~*t:~ t~--~--~ g",/' ¢'~¢ (d;[/~ '5//4 '3 i,,t z_ SEPTIC TANK:. DISTANCE FROM WELL MANUFACTURER INSIDE LENGTH INSIDE WIDTH NUMBER OF MATERIAL ~" I/c¢'~ /o~, COMPARTMENTS LIQUID DEPTH '~' LIQUID CAPACITY DISTANCE FROM WELL NUMBER OF LINES ABSORPTION AREA DEPTH: TOP OF TILE TO FINISH GRADE FOUNDATION "2_"~- I TOTAL LENGTH NEAREST LOT LINE (.Or' OF LINES (o2- ! DISTANCE BETWEEN LINES ~ TRENCH WIDTH ,~¢-~IN. TOTAL EFFECTIVE SQ. FT. LENGTH OF EACH LINE (~"e- / "~ 7 I DEPTH OF FILTER G I ~J~ MATERIAL BENEATH TILE ,1¢4. ABOVE TILE IN. WELL: TYPE _ CONSTRUCTION. DEPTH DISTANCE FROM: BUILDING FOUNDATION NEAREST LOT LINE_ NEAREST SEPTIC SEEPAGE SEWER LINE__, TANK__ SYSTEM CESSPOOL OTHER SOURCES APPROVED DISAPPROVED REMARKS DISTANCES: INSTALLED BY: 5ei '"~ SEWER LINE DEPTH: PIPE MATERIAL:. ~1'~ ~,~'~ ~- LOT SLOPE: ¢~¢ ~ ~'O~ REMARKS: Form LQ-032 DIAGRAM OF SYSTEM grE, ;'r ANCHORAGe Area N~ME OF APPLICant INSTALLATION OF: SEPTIC TANK ~ SEEPAGE Pit DRAIN ~ , OTHER SOIL TEST RESULTS COMPLETION DATE ANTICIPATED FINAL INSPECTION: 24 HOUR NOTICE REQUIRED. BACKFIL'LING OF ANY SYSTEM wITHOUT FINAL INSPECTION BY THE ENVIRONMENTAL QUALITY AUTHORITY WILL BE SUBJECT TO PROSECUTION. DEPARTMENT OF FOUNDATION TO SEPTIC TANK ~ ' /" FOUNDATION TO SEEPAGE PIT SEPTIC TANK TO SEEPAGE PIT WALL SEPTIC TANK SEEPAGE PIT TO NEAREST LOTLINE- DRA,N F,ELD DRAIN DRAIN ALSO CONSIDER AREA WELLS. WATER MAIN TO SEPTIC TANK SEEPAGE PIT DRAIN FIELD · /~ ' '/c?o TO RIVER, LAKE, STREAM. CAST IRON INTO AND OUT OF SEPTIC TANK AND INTO CRIB CROSSING GAP Of EXCAVATION 5 FEET INTO UNDISTURBED SOIL. 4 INCH DIAMETER CAST IRON SIPHON PIPES ON SEPTIC TANK AND SEEPAGE Pit I CERTIFY THAT ~ vi AM FAMILIAR WITH THE REQUIREMENTS OF GREATER ANCHORAGE AREA BOROUGH ORDINANCE NO. 28-68 AND THAT THE ABOVE DESCRIB D SYSTEM IS IN ACCORDANCE WITH SAID CODE. Performed f o r_.)_o5 Legal Descript' This form reports L~.==~ GREATER ANCtlORAGE AREA BOROns? Department of EnvironmenLal Quality 3330 "C" Street Anchorage, A1 aska 99503 SOILS LOG -/~PEROI,ATION TEST Soils log Percolation ~est ~ Depth Feet 1 - 2- 3- 4- 5- 6- 7- 8- 9- 10- 11 ~ 12- 13- 14~ Was ground water encountered? If yes, at what depth? Reading Date Gross Time Net Time Depth to Water Net Drop · -7%-~;Y ' ---1 ....... -~- 'IZ.- L~. ~ J ........ ~-w- .... -/;'?~_ A ..... 1" I Percolation ~-a_t_-~~-: ~_~-n-i-n~te. -Proposed installation: Seepage it Y Drain Field .......... Depth to boLtom of pit or trenci~ Depth of Inlet ............... · COMHENTS: .................................... ',? SIX INCH WATER WELL DRILLED AND CASED OUT TO THE DEPTH OF :/:DRILLED~,~_ AT THE RATE OF .$18,00 PER FOOT. ' '. ' "[!,PROPERTY OWNER l~e Hen~ ~ilson :4~LOCATION OF:WELL. SITE, Lt. ~ B~..~ ~bdi~sion: ~ ~,, , , .. · b¥~':' 0 ..... ~' Gravel ~th several l~go cobbles, ' 28----6~' Sandy gravel, Gravel with several streaks of clay throughout,. Gravel. Several Gobbles and 20% sandy clayo .:.~!,17J--198' Sandy gravel,' ~et. '-~ :~''' .... : ....., ~ '" · ', ,'-* ~:.~,:.;::.':;" ..... ;' '~: ;,,."'"" ":.~: '198--213' Gravel with 30% sandy olay, Water but very silty, ........... :~':"' ':'"::"": .... /'213--217' Clean water .bearing gravel. Casing ~eated to 2~J feet,. Produoing 8GPF~ . .;~'~!o 35 foot head of water off. bottom. Very fast recovery on draw do~m. 3/$ Horse pu~p .j4~hould be installed five feet off bott~n, Cased.bottom, : '.., · . : : ,-..: · , . -. :," ";:', ~ "''[: ' ,,, · . INCLUDES ALL LABOR AND MATERIAL FOR COMPLETION OF SAID DRILLING. : -: iWRITE CHECK PAYABLE TO RAMPART DRILLING WORKS FOR THE SUM OF $3870e00 1- ~'.;J' !:i :.', , -:.7~?~:i¢::i:; :: THANK You VERY MUCH, . ''i ;:' '.i:'. 'k~:~' :: ' .'.' :" ' :i":.,::~ :' BERNIE CLAUS OF RAMPART DRILLING WORKS ~ '? ' TH~i~ "' DATE l~lOV, ~. ?~ "' :'~f .,.': . f.::_..','-' . S~RVIOE CHARGEOF ~% PER MON ,~, ;'t , Municipality of Anchorage Development Services Department Building Safety Division On -Site Water and Wastewater Program 4700 Elmore Road P.O. Box 196650 Anchorage, AK 99507 www.muni.org/onsite (907)343-7904 CERTIFICATE OF ON-SITE SYSTEMS APPROVAL FOR A SINGLE FAMILY DWELLING Parcel I.D. 015-331-23 COSA # OS e 1 `a I ty__T Expiration Date: S 1 " 1. GENERAL INFORMATION Complete legal description Lake C rhe Hills Block 3 Lot 2 Location (site address) . 1-1200 Briggs Ct., Anchorage, AK 99516 Current Propertyowner(s) Mikel Saunders Mailing address Lending agency Mailing address Real Estate Agent Mailing Address Wendy Thomas Day phone Day phone Day phone 440-4976 L,5 Unless otherwise requested, COSA will be held by DSD for pickup. v&Ay 7i,111A5 c*An POL .kp 2. NUMBER OF BEDROOMS: 5 3. TYPE OF WATER SUPPLY: TYPE OF WASTEWATER DISPOSAL: Individual Well 0 Individual On-site 0 Individual Water Storage ❑ Individual Holding Tank ❑ Community Class Well ❑ Community On-site ❑ Public Water System ❑ Public Sewer ❑ The Municipality of Anchorage Development Services Department (DSD) issues Certificates of On -Site Systems Approval (COSA) based only upon the representations given in paragraph 4 by an independent professional civil engineer registered in the State of Alaska. Certificates of On -Site Systems Approval are required for the transfer of title (except between spouses) for properties served by a single-family on-site wastewater disposal and/or water supply system. DSD also issues COSAs upon request to homeowners. Certificates of On -Site Systems Approval are valid for 90 days from the date of issue for properties served by a private or Class C well and may be reissued with new water sample results. (Certificates may be reissued for a period of up to one year with valid water samples.) Certificates are valid for one year for properties served by Class A or B wells or a public water system. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. 4. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, 1 verify that my investigation, based on procedures outlined in the Certificate of On -Site Systems Approval Guidelines for this application, shows that the on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation. Name of Firm Spurkland Enginneering Phone 279-3916 Address 203 W. 15th Ave., Ste 202, Anchorage, AK 99501 Engineer's Printed Name Lars Spurkland Date May 1, 2012 5. DSD SIGNATURE _Z Approved for �� bedrooms. Disapproved. ��.OF A4.gs�a1 ,%,r,P• ' fr Ip�f x.497 puRKIA 0 Qj �•; 1�5�a Conditional approval for bedrooms, with the following stipulations: Attachments COSA Checklist X Septic System Advisory Well Flow Advisory Nitrate Advisory Arsenic Advisory Maintenance Agreements Supplemental Engineer's Report Other By: Original Certificate Date: c (Rev. 11105) Municipality of Anchorage • �` Development Services Department Building Safety Division On -Site Water & Wastewater Program ` 4700 Elmore Road P.O. Box 196650 Anchorage, AK 99519-6650 www.muni.org/onsite (907) 343-7904 CERTIFICATE OF ON-SITE SYSTEMS APPROVAL CHECKLIST Legal Description: LAK& 0` THE Hiu-g BLK 3 LOT 2- Parcel ID: OIs- 331- 23 A. WELL DATA Well type Pevr. If A, B, or C provide PWSID # Date completed ll 17;5 Sanitary seal (YIN) Total depth 21* ft. Cased to _2L5 ft. FROM WELL LOG Date of test Static water level 1192- ft. Well production 8 9— p.m- WATER SAMPLE RESULTS: Coliform Alec, colonies/100 mL Nitrate NO mg/L Arsenic: 1V0 ug/L date of sample: `li t2 B. SEPTIC/HOLDING TANK DATA Well Log (Y/N) Y Wires properly protected (Y/N) Casing height (above ground) 4 12 in. AT INSPECTION 413o/IZ 173 ft. 4.9 g.p.m. Collectedby: LAP -5 Spu RkLghp TankType/Material AVicv MY- TAaKI5T*'LL Date installed S/71zoo S Tank size 1160 gal. Number of Compartments 2 Cleanouts (Y/N) Y Foundation cleanout (YIN) Y Depression over tank (YIN) err High water alarm (Y/N) M Date of pumping 513112- Pumper A+ ilomit S69yi s C. ABSORPTION FIELD DATA Date installed 5? 0$ Soil rating (g.p.d./ftZ or /bdr Z50 System type Dia _reaAc H Length 100 ft. Width Z ft. Gravel below pipe ft. Total depth 11,3 ft. Eff. absorption area f 4o_ft2 Monitoring tube Depression over field /V Date of adequacy test Y 30 12 Results (Pass/Fail) P55 For 5 bedrooms Fluid depth in absorption field before test in. Water added_]Ia gal. New depth21 �5 in. Elapsed Time: 1440 min. Final fluid depth 2-`l in. Absorption rate >= -450 g.p.d. Any rejuvenation treatment (past 12 mo.) (YIN & type) A10 If yes, give date — D. LIFT STATION Date installed 5 S o g "Pump on" level at 44 in. Size in gallons 500 "Pump off"level at 41 in. Datum &Aom TAnk Cycles tested E. SEPARATION DISTANCES 3+ SEPARATION DISTANCES FROM WELL ON LOT TO: Septic tank/lift station on lot IDD+ Absorption field on lot 100 - - Public sewer main N)/� Sewer /septic service line 25 i+ Manhole/Access (YIN) High water alarm level at 49 in. Meets alarm & circuit requirements? Y On adjacent lots Ito t On adjacent lots 1co,+ Public sewer manhole/cleanout IVA Holding tank )VA Animal containment areas 50'4 Manure/animal excrete storage areas IoO t SEPARATION DISTANCES FROM SEPTICIHOLDING TANK ON LOT TO: r i I Building foundation 5 + Property line 5 + Absorption field 5 + Water main /V!A Water service line lo ,+ Surface water 100+ (At. 11) Wells on adjacent lots 100+ SEPARATION DISTANCE FROM ABSORPTION FIELD ON LOT TO: Property line 0m Water Service line 10 + Curtain drain 50 a �N:�• F. COMMENTS i Building foundation 10 t Water main 10 t Surface water 100 '+ Driveway, parking/vehicle storage ,t Wells on adjacent lots 100 t G. ENGINEER'S CERTIFICATION .�' ,Y• _ ;.,sem :9 I certify that I have determined through field inspections and y ,Ij I �� review of Municipal records that the above systems are in i o conformance with MOA COSA guidelines in effect on this date. • • •. • • 0 ` S .SPURKLAND.- / Engineer's Printed Name LAU '�y�o2(vid //j c� . 11 00 ��' Date &IlIzofz 1 \�`\Rd S510NA COSA Fee $ 6W Waiver Fee $ Date of Payment LJ // ((41 a Date of Payment Receipt Number GG2a0G Receipt Number (Rev. 4110) �� 7� N 49� 1 754" VV V 68 >- /?j��,, 10 i0 4s'w ESMy��w ° Little Bear Services grid 2951 Carriage Drive 2659 Anchorage, Alaska 99507 Dra Wn b (907) 350-5541 EjFB GRAPHIC SCALE: I Inch = 50 beet 25 12.5 0 12.5 25 50 i00 `0 Lot 2 i Block 8 S -BUILT - Lak; CTne Hi!ls ield Book Subdivision I hereby certify that the property described hereon has been surveyed by me, or at my direction, and that the improvements situated thereon are within the property lines and do not overlap or encroach on the property lying adjacent thereto unless otherwise shown. That no improvements on the property lying adjacent thereto encroach on the premises in question and that there are no roadways, transmission lines or other easements on said property except as shown. It is the responsibility of the owner or builder, prior to construction, to verify proposed building grade relative to finish grade and utility connections and to determine the existence of any easements, covenants, or restrictions which do not appear on the recorded subdivision plat. ` Listed distances prevail over scaling. Reproduction may cause distortion. OF AL46, BOHHY 5 Bil@NETT L.9-5464 1�v�GS�' r AW 9 ��'SSlONt�• 1�_ Municipality of Anchorage i • Development Services Department Building Safety Division On -Site Water and Wastewater Program 4700 Bragaw Street P.O. Box 196650 Anchorage, AK 99519-6650 www.muni.org/onsite (907) 343-7904 $CEv7' vdrJa* CERTIFICATE OF ON-SITE SYSTEMS APPROVAL FORA SINGLE FAMILY DWELLING /�cc Parcel I.D. _015-331-23 COSA # V B 0 (-3-4- Expiration Date: OR 1. GENERAL INFORMATION Complete legal description LAKE O THE HILLS BLOCK 3 LOT 2 Location (site address) 11200 BRIGGS COURT. ANCHORAGE. AK 99516 Current Property owner(s) FEDERAL NATIONAL MORTGAGE Day phone Mailing address Lending agency Mailing address Real Estate Agent Mailing Address Day phone BOBBROCK Day phone 261-7603 0 Unless otherwise requested, COSA will be held by DSD for pickup. 2. NUMBER OF BEDROOMS: 3. TYPE OF WATER SUPPLY: TYPE OF WASTEWATER DISPOSAL: individual Well ® Individual On-site Individual Water Storage ❑ Individual Holding Tank ❑ Community Class Well ❑ Community On-site ❑ Public Water System ❑ Public Sewer The Municipality of Anchorage Development Services Department (DSD) issues Certificates of Onsite Systems Approval (COSA) based only upon the representations given in paragraph 4 by an independent professional civil engineer registered in the State of Alaska. Certificates of On -Site Systems Approval are required for the transfer of title (except between spouses) for properties served by a single-family on-site wastewater disposal and/or water supply system. DSD also issues COSAs upon request to homeowners. Certificates of On -Site Systems Approval are valid for 90 days from the date of issue for properties served by a private or Class C well and may be reissued with new water sample results. (Certificates may be reissued for a period of up to one year with valid water samples.) Certificates are valid for one year for properties served by Class A or B wells or a public water system. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. 4. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based on procedures outlined in the Certificate of On -Site Systems Approval Guidelines for this application, shows that the on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation. Name of Firm ArcTerra Engineering & Surveying. Inc. Phone 868-3792 Address 20441 PTARMIGAN BLVD., EAGLE RIVER, AK 99577 Engineer's Printed Name KENNETH M. DUFFUS Date 05/13/2008 Engineer's Comments: This investigation was completed in compliance with ADEC and MOA regulations. The assessment of the condition of the well and septic applies only to the conditions as of the day tested. The flow and absorption rates may change due to subsurface conditions that may not be observed from the surface, changes inland use, local soil characteristics, groundwater levels that may fluctuate during the year and the water usage of the family being served by the system. The operational life of all well and septic systems are subject to these various and dynamic characteristics and are outside the control of the evaluator of the well and septic system. Therefore, ArcTerra can not give any estimate of how long a '�Q% OF At 1 system will function satisfactory for current or future �,••.••"•'•••'QS �) occupants or can ArcTerra guarantee that no unseen or C.7 • •ON;It encroachments, deficiencies or discrepancies exist. X* 149TH /} * 1, 5. DSD SIGNATURE Approved for __17 bedrooms. Disapproved. Conditional approval for bedrooms, with the following stipulations: Attachments: COSA Checklist X Septic System Advisory Well Flow Advisory Nitrate Advisory VKUGRAM Arsenic Advisory Maintenance Agreements Supplemental Engineer's Report Other 1) By: Original Certificate Date: (Rm IVD51 ` Municipality of Anchorage • "' Development Services Department Building Safety Division On -Site Water & Wastewater Program 4700 Bragaw Street P.O. Box 196650 Anchorage, AK 99519-6650 www.muni.org/onsite (907) 343-7904 CERTIFICATE OF ON-SITE SYSTEMS APPROVAL CHECKLIST Legal Description: LAKE O THE HILLS BOCK 3. LOT2 Parcel ID: 015-331-23 A. WELL DATA Well type PRIVATE If A, B, or C provide PWSID # _ Well Log (Y/N) Y Date completed 11-17-1975 Sanitary seal (Y/N)Y Wires properly protected (Y/N) y Total depth 215 ft. Cased to 215 ft. Casing height (above ground) 24in. FROM WELL LOG AT INSPECTION Date of test 11/17/1975 )'12/04/2007 Static water level not stated ft. )'171 ft. Well production not stated g.p.m. )'5.75 g.p.rrt. WATER SAMPLE RESULTS: Coliform colonies/100mL Nitrate -ND_ . mg/L Other bacteria_ colonies/100 mL Arsenic: 5.02 mg/I Date of sample: 4!21/08 Collected by: ArcTerra B. SEPTIC/HOLDING TANK DATA Tank Type/Matedal Septic/Steel Date Installed /3/08 Tank size 1250+500 P gal. Number of Compartments y Cleanouts (Y/N) YFoundation cleanout (YIN) y Depression over tank (YIN) p[ High water alarm (Y/N) Y_Date of pumping NA -new tank Pumper C. ABSORPTION FIELD DATA Date installed 5/7/2008 Soil rating (g.p.d./ft= or fe/bdrm) M System type TRENCH Length _=ft. Width Z ft. Gravel below pipe Zft. Total depth 12 ft. Eff. absorption area 1400 fe Monitoring tube Y Depression over field 1`(. Date of adequacy test NA - new system Results (Pass/Fail) _ For _bedrooms Fluid depth In absorption field before test _ in.' Water added_ gal. New depth '_in. Elapsed Time: —min. Final fluid depth _ in. Absorption rate >= g.p.d, Any rejuvenation treatment (past 12 mo.) (Y/N & type) If yes, give date D. LIFT STATION Date installed 5/3/08 `Pump on' level at gamin. Datum Bottom of Tank E. SEPARATION DISTANCES Size in gallons 500 Manhole/Access (Y/N) Y 'Pump off" level at g2_in. High water alarm level at 4 8 in. Cycles tested Meets alarm & circuit requirements? Y SEPARATION DISTANCES FROM WELL ON LOT TO: Septic tank/lift station on lot 100'+ Absorption field on lot 100'+ Public sewer main 75'+ Sewer /septic service line 251+ On adjacent lots 100'+ On adjacent lots 100'+ Public sewer manhole/cleanout 100'+ Holding tank 100'+ Animal containment areas 50'+ Manure/animal excrete storage areas 100'+ SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK ON LOT TO: Building foundation 5'+ Property line 5+ Absorption field 5'+ Water main 101+ Water service line 101+ Surface water 1001+ Wells on adjacent lots 1001+ SEPARATION DISTANCE FROM ABSORPTION FIELD ON LOT TO: Property line 0'+ Building foundation0L + Water main 101+ Water Service line 101+ Surface water 1001+ Driveway, parking/vehicle storage0L + Curtain drain 10'+(NoneKnown) Wells on adjacent lots 1001+ F. COMMENTS 0 Por r.amr WA Pinw Tecl+ G OF All `t♦i_ G. ENGINEER'S CERTIFICATION - wf I certify that I have determined through field inspections and M; •. L„ .. ... review of Municipal records that the above systems are in conformance with MOA COSA guidelines in effect on this : I' nneai �. u„do r ty date. �j s 16 Engineer's Printed Name KENNETH M. DUFFUS ,� j 9FaP «a.••`�i`��r FE Date 05/11/2008 COSA Fee $430.00 Waiver Fee $ _ Date of Payment 4 f�O Date of Payment Receipt Number A? ¢0Receipt Number, (Rev. 11105) 0 E 112TH_ AVE b (E 113TH AVE) — — — — — M / eo OO \�j 1^ C C� CRAV \ v I MN PK -INE \O \ V LOT 1 '`.4�3 CANT yE0' A9 10'x20•CO o 7.a•d2' ��• \ CANT s DECK 1. O• 3116' R� fLr 38.x• EXISTING CANT WELL to ?�J• HOUSE o \ AC ?fir D/w 3•xtr CANT LOT 2 BLOCK 3 Jo•� N68 ti LOT 4 "R9 07 ss, ANCIIORAGE RECORDING DISTRICT iL ASBUILT OF: LAKE O TIIE IIILLS SUBDIVISION LOT 2, BLOCK 3 PLAT 72-236 SURVEY CERTIFICATE: 1, John L. Schuller, Have conducted a physical survey of this property as shown on this drawing and that the improvements situated hereon arc within the property lines and no enchroachments exist other than noted. Under no circumstance should any information on this drawing be used for construction of fences, structurcs, improvements, or for establishing boundary lines. EXCLUSION NOTES: It is the owners responsibility to determine the existence of any easements, covenants, or restrictions which do not appear on the recorded subdivision plat. 08-001 JLS 1 2639 1 0801/44 LOT 3 -i7-� OFgS11) 49TH •ORN L. SCHULI.ER,. a. o LS -10408 e i � e tQ ter, z r 4 tF AND Sowoe,� MUNICIPALITY OF ANCHORAGE Department of Health & Human Services DIVISION OF ENVIRONMENTAL SERVICES 343-4744 CERTIFICATE OF INSPECTION FOR HEALTH AUTHORITY APPROVAL OF ON-SITE SEWER AND WATER FACILITY FOR SINGLE FAMILY DWELLING Parcel I.D. # t'~\Z'~- .~2~ .,~,._.~ HAA# 1. GENERAL INFORMATION (Must be completed prior to submittal) (a) Legal Description (include lot, block, subdivision, section, township, range) Lot 2; Block 3; Lake O~The Hills Subdivision (b) Location (address or,directions) 11200 Briqgs Court,, Anchorage, Alaska Property owner Associated Relocation Manag/~lepbone: (home) Mailing Address Irving,, Texas Business (c) Lending Institution GMAC Mailing Address -'A~'Eb~2ION: Mina O'Delt Telephone (d) RealEstate Company and Agent DYNAMIC REALTY/Beverly Hopkins Address 501 West Northern Liqhts Boulevard,, Anchorage,, Alaska Telephone 271-7611 99503 (e) Mail the HAA to the following address: (or check here I~, if hold for pick up.) List contact person and day phone number below: S & S ENGINEERING/694-2979 17034 Eaqle River Loop Road,, Suite 204 Eaqle River,, Alaska 99577 2. TYPE OF RESIDENCE Single-Family ~[ Number of bedrooms 5 3. WATER SUPPLY Individual Well Z;X Community [] Public [] Note: If community well system, must have written confirmation from the State Department of Environmental Conservation attesting to th legality and status. 4. SEWAGE DISPOSAL On-site I~ Public [] Community [] Holding Tank [] Note: If community well system, must have written confirmation from the State Department of Environmental Conservation attesting to the legailty and status. 72-025 (Rev. 7/88) Page 1 of 2 5, ENGINEERING FIRM PROVIDING INSPECTIONS, TESTS, FILE SEARCH, DATA AND INFORMATION As certified by my seal affixed hereto and as of the validation date shown below, Iverifythat my investigation of this Health Authority Approval shows that the on-site water supply and/or wastewater disposal system is safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is in compliance with all Municipal and State codes, ordinances, and regulations in effect on the date of this inspection. Name of Firm Telephone Address Date S & S ~NGINEERING 17n34 Eagle River Loop Road No, Eagle River, Alaska 99577 6. DHHS APPROVAL Approved for ~ bedrooms by Approved ~//~_.~ Disapproved Terms of Conditiona; Approval Conditional The Municipality of Anchorage Department of Health and Human Services(DHHS) issues Health Authority Approval cerificated based only upon the representations given in paragraph 5 above by an independent professional engineer registered in the State of Alaska. The DHHS does this as a courtesy to purchasers of homes and their lending institutions in order to satisfy certain federal and state requirements. Employees of DHHSdonotconductinspections or analyze data before a certificate is issued. TheMunicipalityofAnchorageisnot responsibleforerrorsoromissions in the professional engineer's work. 72-025 (Rev. 7/88) Back Page 2 of 2 A. WELL DAT/~- Well Classification ~_--~!'~ ~ I~. Well Log Present (Y/N) MUNICIPALITY OF ANCHORAGE (MOA) Health Authority Approval (HAA) CHECKLIST - FEBRUARY 1984 343-4744 Legal Description: Date Completed If A, B, C, D.E.C. Approved (Y/N) ~ .L,) {~"'//~/'~-~" Yield -7. O ,=~ Total Depth .Z I~;~ Cased to ~_J~ Depth of Grouting Static Water Level / "'¢ 2- Casing Height Above Ground / Electrical Wiring in. Conduit (Y/N) SEPARATION DISTANCES FROM WELL: To Septic/Holding Tank on Lot / C~._~ To Nearest Edge of Absorption Field on Lot To Nearest Public Sewer Line To Nearest Sewer Service Line on Lot Water Sample Collected by Water Sample Test Results Pump Set At Sanitary Seal on Casing (Y/N) ~ Depression Around Wellhead (Y/N) ~ ; On Adjoining Lots ; On Adjoining Lots I O0 To Nearest Public Sewer Cleanout/Manhole Comments B. SEPTIC/HOLDING TANK DATA Date Installed ~-~Size Standpipes (Y/N) ~ DepressiOn over Tank (Y/N) Pumping/Maintenance Contact on File (Y/N) / Holding Tank High-Water Alarm (Y/N) td/~ SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK: I ~-"00 No. of Compartments Air-tight Caps (Y/N) cc Foundation Cleanout (Y/N) &j Date Last Pumped -%'"'- ~ ~--- -- ~:;~ ~/~ ;for Temporary Holding Tank Permit (Y/N) To Building Foundation To Disposal Field ! lb- To Water-Supply Well ./ 0 To Property Line To Water Main/Service Line To Stream, Pond, Lake or Major Drainage Course 'Comments .~ ~ .~, C_ 72-026(Rev. 7/88) Front Page I of 2 C. ABSORPTION FIELD DATA Soils Rating in Absorption Strata Date Installed Width of Field ,~, D" Square Feet of Absortion Area Depression over Field (Y/N) Results of Last Adequacy Test ~" z:~/~ .r~ Type of System Design Length of Field / O~ ' Depth of Field {/. ~-- Gravel Bed Thickness ~.-'7. ~ Statndpipes Present (Y/N) Date of Last Adequacy T~st SEPARATION DISTANCE FROM ABSORPTION FIELD: ! To Water-Supply Well To Building Foundation ~'~ ! Lot / O To Water Main/Service Line ~/~ Jr To Property Line { ~ To Existing or Abandoned System on ; On Adjoining Lots ~ ~"¢- To Cutback (if present) ~/{,"~ To Stream, Pond, Lake, or Major Drainage Course To Driveway, Parking Area, or Vehicle Storage Area Comments D. LIFT STATION Date Installed ~ Size in Gallons "Pump On" Level at High Water Alarm Level at Tested for Meets MOA Electrical Codes (Y/N) Comments Dimensions Manhole/Access (Y/N) "Pump Off" Level at Vent (Y/N) Pumping Cycles during Adequacy Test. **Check Permitted Bedroom Rating Against HAA Request** I certify that I have checked, verified, or conformed to all MOA and HAA guidelines in effect on the date of this inspection. Company 17034 Eagle River Loop Road No. 204 Date MOA No. Receipt No. Date of Payment Amount: $ 72-026 (Rev. 7/88) Back Receipt No. Waiver Fee: $ Date of Payment Page 2 of 2 F-'~: D/~E RECEIVED .. '~ INSPECTION APPOINTMENTS ,:¢~j, TIME TIME ~ TIME I INSPECTOR INSPECTOR~"J ~d'~ "/ I NSPECTO~f',~ ~UNICIPALI~ OF ANCHORAGE MUNIOIPALITY OF ANCHORAGE DEPT. OF IC,'LT;I A  DEPARTMENT OF HEALTH & ENVIRONMENTAL PROTEC~NIRONMENTAL 825 L Street - Anchorage, Alaska 99501 ENVIRONMENTAL SANITATION DIVISION REQUEST FOR APPROVAL OF INDIVIDUAL WATER AND SE I I DIRECTIONS: Complete all parts on page 1. Incomplete requests will not be processed. Please allow ten (10) days for processing. . PHONE PROPERTY RESIDENT (If different from above) 2, BUYER PHONE MAILING ADDRESS I MAILING ADDRESS 4, REAL~OR/AGENT PHONE MAILING ADDRESS 5. LEGAL DESCRIPTION ;TREET LOCATION 6. TYPE OF RESIDENCE [~SINGLE FAMILY [] MULTIPLE FAMILY NUMBER OF~BEDROOMS [] One [] ,,/Four [] Two ~ Five [] Three [] Six [] Other 7. WATER SUpPlY [~ INDIVIDUAL* [] COMMUNITY [] PUBLIC UTILITY * ATTACH WELL LOG. Awell log is required for all wells drilled since June 1975. For wells drilled prior to that date, give well depth (attach log if available.) 8. SEWAGE DIS/.~AL SYSTEM E]~ INDIVIDUAL/ON-SITE** [] PUBLIC UTILITY YEAR ON-SITE SYSTEM WAS INSTALLED. NOTE: THE INSPECTION FEE MUST ACCOMPANY EACH REQUEST BEFORE PROCESSING CAN BE INITIATED. THIS SIDE FOR OFFICIAL USE ONLY 1, TYPE OF RESIDENCE NUMBER OF BEDROOMS [] SINGLE FAMILY F~ ONE [] THREE [~] FIVE [~] OTHER [] MULTIPLE FAMILY [] TWO [] FOUR [] SIX PERMIT NUMBER 2, WATER SUPPLY [] INDIVIDUAL DEPTH OF WELL [] COMMUNITY DATE DRILLED [] PUBLIC UTILITY Connection Verified LOG RECEIVED 3. SEWAGE DISPOSAL SYSTEM PERMIT NUMBER [] I NDIVI DUAL/ON -SITE DATE INSTALLED Connection Verified INSTALLER []Sepal Ta~r []HoldingTank Size: J~-.~- If Tank is homemade SOILS RATING TOTAL ABSORPTION AREA MATERIAL 4, DISTANCES Septic/Holding Tank Absorption Area Sewer Line I Nearest Lot Line WELL TO: Absorption Area to nearest Lot Line 5. COMMENTS [~//~PROV ED FOR ~ BEDROOMS [] CONDITIONAL APPROVAL (letter must accompany certificate) [] DISAPPROVED DATE : By 72-01o (Rev. 6/79) , L CHEMICA& Groll \LOGICAL ('s LABORATORIES tF ALASKA, INC. TELEPHONE (907)•279-4014 ANCHORAGE INDUSTRIAL CENTER ,274.3364 5633 8 Street A--.• Drinking Water Analysis Report for Total Coliform Bacteria TO BE COMPLETED BY WATER SUPPLIER WATER SYSTEM: ,.•QLD. NO_ Water System Name C Q Phone No. Mailing Address City ._ State - zip Code SAMPLE DATE: L 1 0 Mo. Day Year SAMPLE TYPE: O Routine ❑ Check Sample (for routine sample 1 Treated Water with lab ref. no. ❑ Untreated Water ❑ Special Purpose SAMPLE Time Collected NO. LOCATION Collected By 3 4 L 5 READ INSTRUCTIONS BEFORE TO BE COMPLETED BY LABORATORY Analysis shows this Water SAMPLE to be: In Satisfactory ❑ Unsatisfactory ❑ Sample too long in transit: sample should 'hot be over 48 hours old at examination to indicate reliable results. Please send new sample. _ i` Date Received i C 1 Time Received ` Analytical Method: ❑ Fermentation Tube ❑ Membrane Filter Lab Ref. No. Result, Analyst m I I m U m ' eNo al cobnee/ 100 ml a No W PovrM pan•one 08.1220 (b) BACTERIOLOGICAL WATER ANALYSIS RECORD Rw. 1278 o.l• cal«e.e eoI'rCe a.m. EMS Brom 24 boursr brava ee nwrer COLLECTING SAMPLE alulllpN Tuba A00.1tr 10-1 Tub" POallt"frOt.I 10ml Portlorla Moment. Fatar. Olre•t Count Collform/1001"1 Verification, LTB — BGS Final Membrana Filter Ra tis / Collform/100m1 �= L.� Date Rworle0 SY Time, p.m. GREATER ANCHORAGE AREA BOROUGH Department of Environmental Quality 3330 "C" Street, Anchorage, Alaska .99503 274-4561 Date Received June 8, 1976 Time of Inspection 10:30 a.m. Date of Inspection 6-9-76 REQUEST FOR APPROVAL OF INDIVIDUAL SEWER & WATER FACILITIES [y ~ FOR Approval requested by:~Alaska Statebank Mailing Address: % Kathy 310 East Northern Lights Blvd. Phone: 2. Property Owner: Gary Mellott Phone: 344-0817 Mailing Address: Star Route a Box 1741M, 99507 3. Legal Description: Lot 2 Block 3 Lake O'Hills Sbdvn 4. Location: Stoneybrook Off of O'Malley, see map 5. Type of facility to be inspected 6. Well Data: Individual A. Type C. Construction Sewage Disposal System: A. Installed C. Septic Tank: D. Seepage Pit: 1975 1. Size /~o 1. Absorption Area Single Family No. of bedrooms B. Depth D. Bacterial Analysis On-site system B. Installer 2. Manufacturer E. Disposal Field: Total length of lines Distances: A. Well to: Septic tank Nearest lot line 215' /~ , Absorption area , Other contamination B. Foundation to septic tank , AbSorption area C. Absorption area to nearest lot line 2. Material Sewer Lines '~ EQ-034 (1/74) Page 1 of two pages MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH AND ENVIRONMENTAL PROTECTION 2510 East Tudor Road, Anchorage, Alaska 99504 276-2221 REQUEST FOR APPROVAL OF INDIVIDUAL SEWER and WATER FACILITIES 1. Type of Inspection: CMRO VA FHA. 2. Property Owner: ~ 1/~ /A~ I I~ H- Mailing Address: 5'/~//~ / 7 ~: / ~ Day Phone: CONV X 3. Name of Buyer:. Mailing Address: 4. Name of Lending Institution: Mailing Address: 5. Name of Realtor or Agent: Mailing Address: 6. Legal Description: Location: Day Phone: Phone: Phone: 7. Type of Facility to be !nspected: 8. Water Supply Type of Supply: Public Utility No. Bdrms. rlndividual ~ If Individual, number of dwellings presently served If Individual, depth of well ~ ( zb Sewage Disposal System Type of System: Public Utility If Individual, date of installation ~-c~ t Individual (on-site) 72 003(3/76) Pa~e 2 of two pages - Req~ t for Approval of Individual S~ r & Water Facilities Le§al Description Lot 2 Block 3 Lake O'Hills Comments Disapproved Approval~Valid for one year from date signed Greater Anchorage Ar~a Borough, Department of Environmental Quality DIAGRAM OF SYSTEM certify that the information contained in this request for approval to be a true and accurate representation of the subject sewer and water facilities and these facilities are operating satisfactorily. SIGNED Date EQ-034 (1/74) I Obinoia) R,4. 1973 ALASA._,JEPARTMENT OF HEALTH AND SOCIAL SER ofS DIVISION OF PUBLIC HEALTH INDIVIDUAL AND SEMbPUBLIC DATE BACTERIOLOGICAL WATER ANALYSIS INDIVIDUAL ❑ SEMI-PUBLIC ❑ CHLORINE RESIDUAL PPM REPORT RESULTS TO J • NAME ADDRESS CITY ZIP CODE ADDRESS OF SOURCE COMPLETE THIS SECTION ONLY IF WATER IS,AN INDIVIDUAL SUPPLY SAMPLE COLLECTED BY r DATE COLLECTED 1 TIME COLLECTED r S.mpFe Collected From ❑ Klch.n Top ❑ Both,.. Tap ❑ Basement Tap ❑ Other (List) Well — ❑ Dv0 8 Driven ❑ other— Drilled❑ Bond SOURCE: ❑ Sprmq Cistern ❑ Dog Well or CO.,. ConslmcHon: Walls—❑ Wad ❑ Concrete 8 Melol 8 Tile Brick or Top ❑ Wood ❑ Conners MNaI Open Top ❑ CO.,,-,* LOCATION:Under No ❑ In Basement ❑ Bm.ment Offset ❑ ❑In Yard ❑ Otho Building Sewer Septic DISTANCE TO: or Otho Drainage Pipe Feet. Tank her. Til. , - S»Page Ces•- Fi.la F«t. P.tf..l, Pool FM, Priv, feet - Otho Possible Sources of Contaminalion _ MATERIAL: Building S.wo • ❑ Cast Iron ❑ Wood ❑ Tile ❑ Fibre ❑ Gm,Io. ❑ nt plastic Joint Material • Type GENERAL: Does Water Become Muddy or Discolored? ❑ Yes O No When? Depth Diameter of Well , v Feet. Well Casing Material Diameter Depth Water Depth length of From Bolcom feet. Drop Pip. Offset in In Wilily PUMP LOCATION: ❑ In Well ❑ Basement ❑ In Basement ❑ Room On Too ❑ Of W.0 ❑ other PURPOSE OF EXAMINATION: Illness Suspected? ❑ Yes ❑ No . ' New Source of Supply? ❑ Yo ❑ No Repairs to System? ❑ Yes ❑ No Signature Lab No. OFFICE Analysis shows this Water SAMPLE to lam Satisfactory Unsatisfactory 0 Questionable O Sample loo long in transit; cample should not be over 48 hour, old at e.nmination to Indicate mlioblo results. Plea" send new sample. ❑ Bottle broken in transit, please send new somple. SANITARIAN'S REMARKS 06.1240 (b) BACTERIOLOGICAL WATER ANALYSIS RECORD , Rev. 1973 READ INSTRUCTIONS Da" R«e;vd ! i /O G Time Pec.ivd —+' .pm Lob. No. • lona" both Iocc IDca 10cc INC lac 1.Occ 1.0.. 24 Hours ON -- 48 Hours Brilliant Green REVERSE SIDE 44 Hours4B Haar, AGAR EMB BEFORE Lader" Broth, 74 hrs. IR hr,. Grans st.in (Most probable No. per 100-4 Coliform 0 ... ;ty -_ MF Results COLLECTING SAMPLEa.m. � 777, Reportedby . Dat. This analysis Indicetes Coliform Organisms to be: Absent - Present