Loading...
HomeMy WebLinkAboutBAUMER LT 1 TR 10Baurner Tract 10 Lot 1 #050-611-18 Municipality of Anchorage '°• Development Services Department " "- Building Safety Division f On -Site Water and wastewater Program, 4700 Bragaw St. P.O. Box 196650 Anchorage, AK 99519-6650 Page 1 of 3 www.cl.anchorage.ak us (907) 343-7904 ON-SITE WASTEWATER DISPOSAL SYSTEM AND/OR WELL INSPECTION REPORT Permit Number: SW070312 PID Number: 050.611.18 Name BAUMER Wastewater System: ❑ New ® Upgrade Amr•aa REINDER RD EAGLE RIVER. AK 99577 ABSORPTION FIELD Priam Nun M searooma a Deep Trenar 0 Shallow Trento 0 Sea 0 idl W O DM«: LEGAL DESCRIPTION Sou Raunq TWW Depen hots ulginal lira,,, Blink LaSrmlwwn NIA 1 0.8 GPD', Dspm to pipe Omor•1 eom ergkw lira,,, 4 A. Gravel EeWn beneath pipe BAUMER SID TR 10 2 Fl. 2 T.tdt P Range secmn Fm amen ahwe otpinal 9raae Ft Waved 1•^110. 0 Ft. 50150 Ft. W ell:New Upgrade ❑ ❑ 0'0W aeatt, Numoer awnMnc•eah«en I.• Dlbws ClauaiWwn IPrrv«s. A B q Total Depen Cassa m EXISTING PRIVATE 5 Fl. Tow aea«pom «sa 2 18.2 Ft P" Material Ft. Ft 630 Fe 3034 PVC Driller Dare DfIWp Sur¢ W alar Laval. InaulM: Oats awaited Ft FLINTSTONE ENTERPRISE8/2112008 y"Parry Ser ai p H caunapnt Above r GPM FL FI TANK SEPARATION DISTANCES ❑ Septic ❑ Holding ❑ S.T.E.P. ❑ Other. To Septic Absorption Lift HoldingubllUPrlvale M.r"a•am« ca�ly From Tank Field Station Tank Sewerl.lne EXISTINGSEPTIC wall 120.8 123.3 130 NIA 95 M°r°`l°l N""'Der °' `°'rya^"" "` S"naosweler 100+ 100+ 100+ N/A LIFT STATION Lot Ln• 41 45 42 N/A s° 500 , ORENCENCO Get Fm al. 6 10.6 10+ N/A '�^• W, le„el at -P«ry m ».el at Hph water alarm M. 40 In 36 n 45 In. Cunun Drun 50+ 50+ 50+ NIA Peep make a Mmol el"'" ln•paclona penormea by P2005•1 QISIA/4 ria j IgG, Remark,, A BUST IN ELEVATIONS NESSECITATED THE INSTALATION OF A BENCH MARK 500 GALLON STEP TANK. ENTIRE FIELD INSULATED WI 2" RIGID CONCRETE TE LAN CONCRETE LANDING AT BASE OF STAIRS IN BACK YARD INSULATION. Assurtwa El.uw. 100.0 Ft Inspections performed by: PANNONE ENG. SVC, LLC Dates: 1" 8121/2008 Engineer's Stamp 6,&•. R ♦♦♦ 2ne 8.21.08 Development Services Department Approval ��.Ol� •••• . �p ,... ' �5��♦i : �•:• ♦ ConditionalApproval Date: r �9TTH l\ ?'�♦s • 0 .................. .... ......... ..� ♦ ?: :Steven R. Ponronet ��� °moi Reviewed and approved by: Date: — 3 " d $ nl� CE 81agq9 ♦jz(.•''�': Ig<v. Dain) 1 121. EXIST'G 3BR, \ V/ W 3 1 IEXIST'G CR 1 O'x1 O'x7'ED EXIST'G 3 SEPTIC 3 / AREA 259, r ac !/ 3 O'RIEDNER RD I 3 259, 123.3 ` s19. 3 7. 15.0/ \ 4 7 v/ . f' JOg SEPTIC VK. INSTALLED /29/07. INSTALL WAY BALL VALVE DCO. W SA1259, CA. 50 F X 5' WIDE 2' ED, 47D INSTALLED MT AT EACH END IN BOTH TRENCHES. 134419 154.4.1 /-l% NEW 50 STEP TANK 259, EXIST'G SEPTIC f AREA t\ MI £A DOWNSLOPE WAS / W�I P£CTED FOR SURFACE T£R. NONE FOUND W/lN l� 140 FEET OF NEW ` ` DRRAIN FIELD UG?j259+ I Iplj NOTES: PANNONE ENG SVC, LLC Date 5 RECORD DRAW NG P.O. BOX 101954 ANCHORAGE, AK 99510 9-x-08 PHONE (907) 272-8218 FAX (907) 272-8211 Scole *: 4 1:50 BAUMER S/D, TR 10, LOT 1 / P.I.D. NO PATRICK BAUMER50-611-1 24212 O'REINDER RD �I �1eveCER8149 rio+e/ PERMIT NO. 1 EAGLE RIVER, AK 99577+cf•,� sw070312 PLAN (907) 694-9442 ��l���o'£s4au�_ Sheet of 3 \\ ��- A B M1 56.3 61.5 M2 50.7 50.1 M3 15.2 33.4 M4 14.6 16.6 LS 31.0 15.8 TC❑ 32.4 15.2 CI 33.7 15.7 DV 134.7115.7 Iplj NOTES: PANNONE ENG SVC, LLC Date 5 RECORD DRAW NG P.O. BOX 101954 ANCHORAGE, AK 99510 9-x-08 PHONE (907) 272-8218 FAX (907) 272-8211 Scole *: 4 1:50 BAUMER S/D, TR 10, LOT 1 / P.I.D. NO PATRICK BAUMER50-611-1 24212 O'REINDER RD �I �1eveCER8149 rio+e/ PERMIT NO. 1 EAGLE RIVER, AK 99577+cf•,� sw070312 PLAN (907) 694-9442 ��l���o'£s4au�_ Sheet of 3 \\ ��- 1. ALL CONSTRUCTION SHALL BE INSTALLED AS SPECIFIED IN THE MOST CURRENT EDITION OF THE MUNICIPALITY OF ANCHORAGE STANDARD SPECIFICATIONS (MASS) FOR COMPONENT PARTS AND MATERIALS USED IN CONSTRUCTION OF ON-SITE WASTEWATER DISPOSAL SYSTEMS. ALL WORK SHALL BE IN ACCORDANCE WITH THE ATTACHED SPECIFICATIONS. 3. SCOPE OF WORK: 3 -BEDROOM HOUSE, NEW DRAIN FIELD. CONNECT TO TANK INSTALLED 11/29/07. 4. GROUNDWATER IS NOT EXPECTED TO BE ENCOUNTERED DURING EXCAVATION, AS EVIDENCED BY THE SOIL TEST HOLE INFORMATION ABOVE 8 FT. IF AN APPARENT WATER TABLE IS OBSERVED IN ANY OF THE EXCAVATIONS LESS THAN 4 FEET BELOW EXISTING GRADE, NOTIFY THE ENGINEER IMMEDIATELY. 5. ENCOUNTERED A CONFLICT IN ELEVATIONS BETWEEN EXISTING GRAVITY FEED LINE AND NEW PROPOSED FIELD. THE PROPOSED FIELD WAS SIGNIFICANTLY HIGHER THAN THE EXISTING LINE. THIS NESSECITATED A 500 GALLON STEP TANK TO BE 'NSTALLED. 2' Rgid ImuLe M• F1kel:ebk: as .• r 20� Drein mak e'a p, ao v na I � � w 2.0 �-� J• dl m. pod pipe. 1.0 T -I 1 INN" ®30'O.C. MwM)M Wal SECTION wa ewv nwwa �ewwaawc,o. wwve.wnw PROFILE DESIGN PARAMETERS ABBREVIATIONS LEGEND N0. BEDROOM: 3 NO. COPPER —v WATER LINE/ TANK SIZE: 1,000 gallon DIP DUCTILE IRON PIPE WELL RADIUS PERC. RATE: 14.4 MPI TH TEST HOLE _ss —ss — o SOIL RATING: 0.8 gpd/SF FC FOUNDATION CLEAN-OUT �ts _n _ NEWTSEPTCTIC APPLICATION RATE: 188 SF/BR T# TANK CLEAN-OUT NO. o o CHAINLINK FENCE AREA ROD: 564 SF CO CLEAN-OUT INDEX CONTOUR SYS. TYPE: 5' WIDE TRENCH, 2' ED MT MONITOR TUBE INTERMEDIATE CONTOUR A RF = 0.70• MIN LENGTH: 79 LF DCO DOUBLE CLEAN-OUT ldE; R.I. RIGID INSULATION (4' INTERVALS) O N 2 EACH 5OLFx5'Wx2'ED,4.0' TO SAS SOIL ABSORSTION SYSTEM S TOTAL AREA: 630 SF u NOTES: PANNONE ENG SVC, LLC _ OF A(\,111 pole a P.O. BOX 102954 ANCHORAGE, AK 99510 . •• . 9_2q_08 RECORD DRAWING PHONE (907) 272-8218 FAX (907) 272-8211 ig�P'' S:�q �� Scale TH. • * �� NTS BAUMER S/D, TR 10, LOT 1 j " ""•" ' P.I.D. NO = PATRICK BAUMER50-611-1 -m 24212 O'REINDER RD / teven .'Pannone j PERMIT No. 3` EAGLE RIVER, AK 99577 I �I+�4s' CE 8149 SW070312 v d PLAN (907) 694-9442 Sheet P 3 of 3 I creep+s rm��.wwa.0 f weanwwmvv II 1 I wa ewv nwwa �ewwaawc,o. wwve.wnw PROFILE DESIGN PARAMETERS ABBREVIATIONS LEGEND N0. BEDROOM: 3 NO. COPPER —v WATER LINE/ TANK SIZE: 1,000 gallon DIP DUCTILE IRON PIPE WELL RADIUS PERC. RATE: 14.4 MPI TH TEST HOLE _ss —ss — o SOIL RATING: 0.8 gpd/SF FC FOUNDATION CLEAN-OUT �ts _n _ NEWTSEPTCTIC APPLICATION RATE: 188 SF/BR T# TANK CLEAN-OUT NO. o o CHAINLINK FENCE AREA ROD: 564 SF CO CLEAN-OUT INDEX CONTOUR SYS. TYPE: 5' WIDE TRENCH, 2' ED MT MONITOR TUBE INTERMEDIATE CONTOUR A RF = 0.70• MIN LENGTH: 79 LF DCO DOUBLE CLEAN-OUT ldE; R.I. RIGID INSULATION (4' INTERVALS) O N 2 EACH 5OLFx5'Wx2'ED,4.0' TO SAS SOIL ABSORSTION SYSTEM S TOTAL AREA: 630 SF u NOTES: PANNONE ENG SVC, LLC _ OF A(\,111 pole a P.O. BOX 102954 ANCHORAGE, AK 99510 . •• . 9_2q_08 RECORD DRAWING PHONE (907) 272-8218 FAX (907) 272-8211 ig�P'' S:�q �� Scale TH. • * �� NTS BAUMER S/D, TR 10, LOT 1 j " ""•" ' P.I.D. NO = PATRICK BAUMER50-611-1 -m 24212 O'REINDER RD / teven .'Pannone j PERMIT No. 3` EAGLE RIVER, AK 99577 I �I+�4s' CE 8149 SW070312 v d PLAN (907) 694-9442 Sheet P 3 of 3 Oct 00 2000 1:22PH HP LASERJET FRX October 8, 2008 Pannone Englneering Services, LLC Steven R. Pannone, P.E. P.O. Bax 102954 Anchorage, AK 99510 FAX#272-8211 tiring Son Qectric, IGQ16WoodlnrJ Drive Z:ag :eRiver, AK CQ577 ;907j 622-6777 Re: Pat Baumer 0 24212 ORledner Road - Eagle R'ver, AK 99577 Dear Mr. Pannone: The lift station at the above referenced property has been wired In accordance with NEC and State/Localcodes. Thank you. Sincerely, Kevin Hombuclde, Owner Administrator License Number 1284 Specia ty Contractor Lkense Number 27285 cc: file P.1 MUNICIPALITY OF ANCHORAGE lf1 Development Services Department 1�D On -Site Water Q Wastewater Program 4700 South Bragaw Street ��10� 1� P.O. Box 196650, Anchorage, AK 99519-6650 q (907) 343-7904 ON-SITE WASTEWATER DISPOSAL SYSTEM / WATER SUPPLY PERMIT Upgrade Permit Number: SW070312 Legal Description: BAUMER LT 1 TR 10 Design Engineer: 0062 PANNONE ENGINEERING SERVI( Owner Name: PATRICK BAUMER Owner Address: 24212 O-RIENDER ROAD EAGLE RIVER. AK 99577 - Date Issued: Nov 26, 2007 Expiration Date: Nov 25, 2008 Parcel ID: 050-611-18 Site Address: 024212 O-RIEDNER RD Lot Size: 62291 SQ. FT. Total Bedrooms: 3 Permit Bedrooms: 3 This permit is for the construction of. ❑✓ Disposal Field ❑ Septic Tank ❑ Holding Tank ❑ Privy Q Private Well ❑ Water Storage All construction must be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal Code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations ( 18AAC72 ) and Drinking Water Regulations ( 18AAC80 ). 3, The engineer must notify DSD at least 2 hours prior to each inspection. Provide notification by calling (907) 343-7904 (24 hours ). ( Not required for a Water Supply Permit only). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must be either: A. Open and closed on the same day. B. Covered, sealed, and heated to prevent freezing. 5. The following special provisions. A. Permit has been revised to include the absorption field. Received By. / ryz'✓Lt Z2 Xr rt " Issued Date: 81 q, Ps Date: _"Z'_01/_ Pannone Engineering Consulting Engineers (9071 272-8218 July 30, 2008 Services, LLC Municipality of Anchorage Development Services Department On -Site Water R Wastewater Program 4700 S. Bragaw Street P. O. Box 196650 Anchorage, Alaska 99519 Subject: Baumer S/D Lot 1 Septic System Permit Upgrade Request Modification to Permit No. SW070312 Ladies and Gentlemen: P.O. Box 102954 ge, Alaska, 99510 I am writing to request that Permit Number SW070312 to modify to include the installation of a new drain field as well as a septic tank. This permit was issued in November of 2007 to install a new septic tank. The permit request indicated that a drain field design would follow this summer. The tank was installed in November of 2007 and the Record Drawing is on file with your department. Design Parameters The proposed systems will serve an existing three-bedroom house. Currently the lot is developed. The Owner wishes to have a new drain field, since the original field in nearing failure. The lot is served by a private water supply that is to be reused. The existing septic systems shall be reused by tying the two fields together with a diverter valve.. The surrounding developed lots are served by private water systems. The private wells are located over 100 feet from the proposed soil absorption system. 1. Soils. A single test hole was excavated in November of 2007. Ground water was monitored through the spring high ground water period of 2008 and was monitored at a depth of 8 feet on May 15, 2008 and remained at that depth in July 21, 2008. Bedrock was not encountered in the test holes. It is my opinion, based on the results of the percolation tests and overall soils appearance an application rate of 0.8 gpd/sf using a conventional system. 2. Upgrade System a. Percolation Rate: b. Application Rate: c. Design Flow: d. Min. Absorption Area: e. Total Depth: f. Effective Depth: g. Reduction Factor h. Width: i. Minimum Length: j. Design Length: k. Effective Absorption Arca: 1. Septic Tank Size: 5 to 15 Min Per Inch 0.8 gpd/sf 450 gallons per day 563 sf 4 feet 2.0 feet 0.70 5.0 feet 79 feet 100 feet 630 sf 1000 gallon. Page 2 of 2 3. Surface Water: There is no surface water within 100 feet of the proposed septic tank and the existing drain field. The record information from your Department shows a storm drain and surface water on lot 4 Baumer S/D. The area was searched on July 291h after a heavy rain and no surface water could be found within 100 feet of the proposed system .The proposed drain field upgrade will maintain at least 100 feet from all surface water and drainage ditches. 4. Topography: The average topography in the area of the proposed septic system is approximately 1 percent based on survey information. The proposed installation will be 27 feet from the shoulder of the steep slopes (2h:lv). Sheet 4 shows that placing this system in the design location will not cause effluent to "day- light" along the 2:1 slope. 5. Drawing Markings: The Drawings are marked "For MoA Review Only". When written notification that the review is complete and that there are no further comments is received from MoA On -Site Department, the note will be removed and "Issued for Construction" drawings will be issued. The proposed installation will not affect the future development of the surrounding or existing lots. There are no wells or septic systems within 100 feet of the proposed septic location. If you have any questions or concerns, please contact me at 272-8218. Sincerely, Steven R. Pannone, P.E. Owner/Civil Engineer Attachments: W:\PES Work Files\Letters\Baumer Lt 1_01 Ldoc IW �e-138 83-JJJ N S D 4 3 M 5 THIS PROJECT ,/ r1 I [I'RIEDNER 1 \ lC 3 3 3 ",i M� 3 r� w � 7�Tt�� 7�T� ^ _ NOTES: PAMONE ENG SVC, LLC ��pF A�gSII 08/1/08 P.O. BOX 102954 ANCHORAGE, AK 99510 „gyp.•' ��� S"Te ISSUED FOR CONSTRUCTION PHONE (907) 272-8218 FAX (907) 272-8211 • • • � TH *�j� 1;100 •• • BAUMER S/D, TR 10, LOT 1 � P.I.D.I.D. NN O —t PATRICK BAUMER teven nnoae j PERMIT NO. 24212 O'REINDER RD CE 8149 �� PERMIT EAGLE RIVER, AK 99577 '1? •. . Sheet PLAN (907) 694-9442 k\� ��� 1 of 5 I 3 O'RIEDNER RD 1 3 �25% EXIST'G 1000g TANI ABANDONED IN PLACE`1Pp CODE 27'2 INSTALL FL gW SPLITTER 12112 .8 UPGRAQFFF_ SAS 2 EA. EXIST'G 3BR 4.5 LF X 5' WIDE 2' ED, 4'T OUSE -----BM F C INSTALL CO AT EACH END. f 5 INSTALL MT AT EACH END IN BOTH TRENCHES. cV/ W ;\ 130.819 3 \ / l�i� 10.0 �• e„ J TH 27.01/ XIST'G CR 15.0 �79 O'x1O'X7'ED ,,.,—EXIST'G' 3 SEPTIC / N 3 / AREA NEW 10009 SEPTIC �25Z TANIX. INSTALLED ll/,9/07. INSTALL 3-W\Y BALL VALVE 259 & D 0. EXIST'G `2 !/ AREA DOWNSLOPE WAS SEPTIC f AREA INSPECTED FOR SURFACE WATER. NONE FOUND W/IN M 100 FEET OF PROPOSED / DRAIN FIELD UPGRADE. �259. 25/ 4 NOTES: PANNONE ENG SVC, LLC SOF ___x, ume �gStr1) 8/1/08 P.O. BOX 102954 ANCHORAGE, AK 99510 �,7p. F ( Scole ISSUED FOR CONSTRUCTION PHONE (907) 272-8218 FAX (907) 272-8211 ,00 * ,•,+�� 7:50 BAUMER S/D, TR 10, LOT 1 j "' ' "" "'• P.I.D. NO PATRICK BAUMER351 0-811-1 %leven nnone j 24212 O'REINDER RD �� • CE 8149 � PERMIT NO. EAGLE RIVER, AK 99577.,_� PERMIT PLAN (907) 694-9442 'klj��orEssO�� S2 OF 5 TEST HOLE PES 1 SLOPE TE PLAN VATER LEVEL READING Top Soil OR 1 ll:�fi 0.5 - 2 12:16 Fill Silty Grovel 7.32' \ 3 1.5 GM ❑'RIEDNER 1 - Root Material OR 12:6 }0 MIN 7.35' 2 Organics 5 12:46 5.26' - 6 1:16 3 1 2.06' 4 5 3 ------ ----TEST TEST I ---- 8 SM/GM Sand Gravel/ HOLE Silty Gravel 3 9 3 10 11 WAS GROUND WATER SLOPE 12 ENCOUNTEREDT Yes 13 IF YES. AT WHAT TEST HOLE DEPTH? -14' 14 DEPTH TO WATER AFTER 15 BOH MONITORING? -14' 16 DATE, 11-28-07 DATE, 5/18/08. DTW: -8.0' 17 DATE: 7/21/08. DTW: -8.0' 16 PERCOLATION RATE 14.4 (min/inch) PERC HOLE DIAMETER 6 inches TEST RUN BETWEEN 4 FT AND 5 FT DATE PERFORMED: 11-28-07 COMMENTS: Test hole excavated by Flintstone. Test Hole was presoaked before perc test. PERFORMED BY: Steven R. Pannone, P.E. I CERTIFY THAT THIS TEST WAS PERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPAL O7UID77LIITTN��ES IN ON THE DATE OFTFIIS TEST. NOTES: T�EFFECT Pl11\1\ONE E G SVC, LLC P.O. BOX 102954 ANCHORAGE, AK 99510 PHONE (907) 272-8218 FAX (907) 272-8211 � SOF A .,q '(�••"'•�:qS,�) :Fy�� • * �/ jPINOPATRICK Un'�eveW: 8149 o i/ �i 4r• . •r IIl� Date 8/1/08 FOR RENEW ONLY ISSUED FOR CONSTRUCTION Scale NTS BAUMER S/D, TR 10, LOT 1 BAUMER/ 24212 O'REINDER RD EAGLE RIVER, AK 99577 0611-t�/�CE PERMIT PERMIT NO. She t PLAN (907) 694-9442 orz`a� 5 READING CLOCK TIME NET TIME VATER LEVEL READING NET DROP 1 ll:�fi 5.26 - 2 12:16 30 uiN 7.32' 2.0' 3 12:16 5.26• - 4 12:6 }0 MIN 7.35' 2.09• 5 12:46 5.26' - 6 1:16 }0 uiN 7.34' 2.06' i 100 PR POSED DRAIN FIELD I 25% FILT S.OPE A 4E I 7PIP g❑ INV FIELIll=87. 89.5 I Gp _ 83.5 90 I I so PAX - X40 V 94 4 I 02 i WA E VEL j-8.0 d RD 1 1x20 10110 i 78 ' M60 I 10.80 1100 11-20u .60 2O ..0 11 11:00 4!.00 12420 12 t0 76 SECTI CLE-. L. IN A 74 I j 72 70 NOTES: P•Q B�Xo1012 54 ANC ANCNG HORAGE, LL10C PHONE (907) 272-8218 FAX (907) 272-8211y�F'•'9�j� (E�FA�gSI�) /* *� j " "' """ '•�teven onnor+ej �j •• CE 8149 � t 4�i.•� Date 8/1/08 ISSUED FOR CONSTRUCTION SSCALE BAUMER S/D, TR 10, LOT 1 PATRICK BAUMER811-1 24212 O'REINDER RD EAGLE RIVER, AK 99577 (907) 694-9442 R•LD. NO PERMIT N0. PERMIT PLAN SPECIAL PROVISIONS TO SPECIFICATIONS 1. ALL CONSTRUCTION SHALL BE INSTALLED AS SPECIFIED IN THE MOST CURRENT EDITION OF THE MUNICIPALITY OF ANCHORAGE STANDARD SPECIFICATIONS (MASS) FOR COMPONENT PARTS AND MATERIALS USED IN CONSTRUCTION OF ON—SITE WASTEWATER DISPOSAL SYSTEMS. 2. ALL WORK SHALL BE IN ACCORDANCE WITH THE ATTACHED SPECIFICATIONS. 3. SCOPE OF WORK: 3—BEDROOM HOUSE, NEW DRAIN FIELD. CONNECT TO TANK INSTALLED 11/29/07. 4. GROUNDWATER IS NOT EXPECTED TO BE ENCOUNTERED DURING EXCAVATION, AS EVIDENCED BY THE SOIL TEST 40LE INFORMATION ABOVE 8 FT. IF AN APPARENT WATER TABLE IS OBSERVED IN ANY OF THE EXCAVATIONS LESS THAN 4 FEET BELOW EXISTING GRADE, NOTIFY THE ENGINEER IMMEDIATELY. 7 Rigid InaWabon Fitter Fatic or 2.0 Drain wk 8' Wove pipe e+ I I � ap 2.0 fie• rkamdrain pipe TI I~Drain rock below pipe kw. vu•w+wr aw+ro mu SECTION ,ti f•CA MOy TANK INSTALLED 11/2910) PROFILE r wa rue•`1, w rwn � ucnv, ro+o.e+w� DESIGN PARAMETERS ABBREVIATIONS x CU COPPER NO. BEDROOM: 3 DIP DUCTILE IRON PIPE i 1,000 gallon TH TEST HOLE PERC. RATE: 14.4 MPI FC FOUNDATION CLEAN—OUT SOIL RATING: 0.8 gpd/SF 5 TANK CLEAN—OUT NO. APPLICATION RATE: 188 SF/BR CO CLEAN—OUT AREA ROD: 564 SF SYS. TYPE: 5' WIDE TRENCH, 2' MT ED MO.pe RF = 0.70, MIN LENGTH: 79 LF DCO DOUBLE CLEAN—OUT USE' / HFaO RIGID INSULATION ,ti f•CA MOy TANK INSTALLED 11/2910) PROFILE r wa rue•`1, w rwn � ucnv, ro+o.e+w� DESIGN PARAMETERS ABBREVIATIONS Dote 8/1/08 CU COPPER NO. BEDROOM: 3 DIP DUCTILE IRON PIPE TANK SIZE: 1,000 gallon TH TEST HOLE PERC. RATE: 14.4 MPI FC FOUNDATION CLEAN—OUT SOIL RATING: 0.8 gpd/SF T# TANK CLEAN—OUT NO. APPLICATION RATE: 188 SF/BR CO CLEAN—OUT AREA ROD: 564 SF SYS. TYPE: 5' WIDE TRENCH, 2' MT ED MONITOR TUBE RF = 0.70, MIN LENGTH: 79 LF DCO DOUBLE CLEAN—OUT USE' R.I. RIGID INSULATION 2 EACH 50LFK5'Wx2'ED,4.0' TO SAS SOIL ABSORBTION SYSTEM TOTAL AREA: 630 SF LEGEND —w—w—WATER LINE/ WELL RADIUS —ss—ss— EXIST'G SEPTIC —ss—ss— NEW SEPTIC ---�� CHAINLINK FENCE INDEX CONTOUR ----- --- INTERMEDIATE CONTOUR (4' INTERVALS) NOTES: Ce LLC P.O. BOX 102954 ANCHORAGE, AK 99510 PHONE (907) 272-8218 FAX (907) 272-8211 =��� ���\\ ��OFA4..4 1 Gj�P .f. Aw . #0, "'."'ZJ.D. �''''j/ teven annore �� �•, CE 8149 (4 0 •� (1I%gj� qt. Dote 8/1/08 ISSUED FOR CONSTRUCTION Scale SCALE SCALE BAUMER S/D, TR 10, LOT 1 PATRICK BAUMER 24212 O'REINDER RD EAGLE RIVER, AK 99577 (907) 694-9442 NO 50-611-1E PERMIT No. PERMIT PLAN sheet 5 OF 5 Municipality of Anchorage • --\ Development Services Department Building Safety Division On -Site Water and Wastewater Program 4700 South Elmore St. P.O. Box 196650 Anchorage, AK 99519.6650 www.ci.anchorage.ak.us (907) 343-7904 ON-SITE SEWER/WELL SUBMITTAL COMMENT SHEET To: PES Legal description: Baumer: Tract 10, Lot 1 ®Permit ❑C.O.S.A. ❑Inspection Report The attached paperwork has been reviewed and is being returned for the following reasons: 1. Drain Field — Depth: Sheet 4/5 shows the drain field depth at an elevation that appears to be 0.5 feet above the stated depth in the callouts. Please revise the design as needed to be in agreement. j2e/kS d--3 2. Monitor Tubes and Cleanouts: The plans appear to be showing most of the monitor tubes and cleanouts, but do not tail them out. Please revise the plans as needed to include requirements (callouts) for monitor tubes and cleanouts, i.e.: double cleanouts after the septic, cleanouts in the drain fields, monitor tubes in the drain fields. QZ_ WAS Cdo. 3. After the "Review Only" drawings have been reviewed and you are notified that there are no additional comments, the "For Construction" drawings must be submitted before the permit is issued. The permit won't be issued until the two sets of drawings have been compared. TSS�rdD �'o<z. ee,.�s—murcl��� Name of reviewer: Jam( Date: 7131108 Please supply the necessary information and re -submit your request. LEAVE THIS FORM ATTACHED TO THE PAPERWORK Municipality of Anchorage ll Development Services Department �titi ly' \ Building Safety Division On -Site Water and Wastewater Program, 4700 Bragaw St. Pagel of 2 P.O. Box 196650 Anchorage, AK 99519-6650 www.cl.anchorage.ak.us (907) 349-7904 ON-SITE WASTEWATER DISPOSAL SYSTEM AND/OR WELL INSPECTION REPORT rertnn tvut,1-- Wastewater System: [3New ® Upgrade Patrick Sau ABSORPTION FIELD AACretl. Pnaw: 2212 Q'riender Road Ea N~ d Bwroan+: C3 DNO Tench O Shsl O T,.nc O Bee ❑ Mane (3 Olney: SM Flaonq. `,' TM, GWM ham or,ginel gre0e: LEGAL DESCRIPTION Da We t~, hom«Ip+W 9rede - OrevN UepM h.n•etn qpe: OM La Bbce c SIOEiN•Un: Baume+ -` Ft. 1 Se hon: F6 WeeE Nwve p,91nN greee, - GrwN L«pm: Tww�Wp. Penge'. -- Ft. GIe"N vmm�'. NurrDer N IInM D�NerKa Mtwe Well: ❑New ❑ Upgrade _ - Ft. C4urts.uan (P,rvaw A B. C): TOW DWM: Cs wl to: T.. �� •.w- Pipe Met.."1 F? 3034 Exist' Private Ft. A V Deu M0011":DrN«- D.t. Dmlea. SWmwN. Lev1. _ .F 'il nstone Services 1112912007 Ft Pamp s« •t: cee"w N«9m Al GmwW: -. TANK yow,, Fl. Ft. GPM SEPARATION DISTANCES 0 septic O Holding ❑ S.T.E.P. 0 Other: To rtv8tS Septic Absorption Lift H Menatedur.r. 1000 Get. Anchorage Tank Fran Tank Tank Field Station Tank Sewer Ll� a MN«4I Numner of C-- W" �� q$ Steel wNI 120.8 LIFT STATION san.o. w.l« 100.0 enu ecWmr. is La Un 200.2 GN 'Puny On• IMI N: "PIuM OnIMI N. Wqn wel« elerm 1 5.0 ` M FWneNian PM Melo 6 MOON Eiemr� M•pealWae pMam•O try: Cann Drvn 50+ BENCH MARK Re ,� REPLACED TANK ONLY , e1,, BACK DECK & THRESHOLD Inspections performed by: PANNONE ENG. SVC, LLC Dates: 1M 1112912007 2nd 1112912007 Development Services Department Approval Conditional Approval Date: -IR- Reviewed and approved by: f k n a 4 . N. 100.0 Ft. Engineer's Stamp 4 c1 ,.• ' 49L - No. CE 8149 O'RIEDNE'k_ R%7 7 11^ / 4 17.1 ' £XIST'G JBR .y HOUSE / E ni W 3 � EXIST'G SEPTIC 3 3 AREA 7 WELL 3 259 1 259. 19, / T'G 10009 TAN ((( C COLLAPSED! ABANDONED F IN PLACE PER CODE 8 5.0 EW 1000g SEPTIC 1� TANK. INSTALL DCO. 1� CONNECT TO EXIST'G SYSTEM D 2� •TH1 200. •� 'G CRIB _19, .0 x 10 x ni a� DESIGN PARAMETERS NO. BEDROOM: 3 IS TANK SIZE: 1.000 gallon r n In n n n CONNECT TO EXIST'G FIELD �I I b• NEW 110009 SEPTIC *: 49 Tr1 � •••.* ' SCeden' R'.' P 'ria oi- 1. ;:. CE 8149 .�% e w. ¢a.° "am PANNONE ENG SVC, LLC P.O. BOX 102954 ANCHORAGE, AK 99510 PHONE (907) 272-8218 FAX (907) 272-8211 Bauder S/D, Tr 10, Lt 1 Patrick Bauder 24212 D'Riender Rd Eagle River, AK 99577 (907) EXIST'G SEPTIC SWING TIES Date 11/26/07 A I B I C T1 FC P.I.D. NO 50-611-1E 20.0 PERMIT NO. SW070312 2a.3 C 1 7.0 5.9 T1 8.4 29.0 T2 13.8 33.1 DC 14.3 34.8 TH 44. REVISED Date 11/26/07 rd awina Scale 1•-50' 105/07 P.I.D. NO 50-611-1E PERMIT NO. SW070312 DESIGN PLAN shtQ MUNICIPALITY OF ANCHORAGE Development Services Department On -Site Water 8 Wastewater Program A I W 4700 South Bragaw Street P.O. Box 196650, Anchorage, AK 99519-6650 1` (907) 343-7904 ON-SITE WASTEWATER DISPOSAL SYSTEM PERMIT Upgrade Date Issued: Nov 26, 2007 Expiration Date: Nov 25, 2008 Permit Number: SWO70312 Parcel ID: 050-611-18 Legal Description: BAUMER LT 1 TR 10 Design Engineer: 0062 PANNONE ENGINEERING SERVI( Site Address: 024212 O'RIEDNER RD Owner Name: PATRICK BAUMER Lot Size: 62291 SO. FT. Owner Address: 24212 O'RIENDER ROAD Total Bedrooms: 3 Permit Bedrooms: 3 EAGLE RIVER. AK 99577 - This permit is for the construction of: ❑ Disposal Field ❑d Septic Tank ❑ Holding Tank ❑ Privy ❑ Private Well ❑ Water Storage All construction must be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal Code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72 ) and Drinking Water Regulations ( 18AAC80 ). 3, The engineer must notify DSD at least 2 hours prior to each inspection. Provide notification by calling (907) 343-7904 ( 24 hours ). ( Not required for a Water Supply Permit only ). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must be either: A. Open and closed on the same day. B. Covered, sealed, and heated to prevent freezing. Received By: Issued By. d4 4L4 Date: A 11 d 07 Date: Municipality of Anchorage • -�1 Development Services Department a Building Safety Division On -Site Water and Wastewater Program 4700 Bragaw Street S. t" P.O. Box 196650 Anchorage, Alaska 99519-6650 www.muni.org/onsite (907)343-7904 ON-SITE SEWER/WELL PERMIT APPLICATION FOR A SINGLE FAMILY DWELLING Parcel I.D. 050.611.18 Property owner(s) Patrick Baumer Day phone Mailing address24212 O'Riender Rd, Eagle River, AK Zip Code 99577 Site address 24212 O'Riender Road Zip Code 99577 Legal description (Sub'd., Block & Lot) Baumer SID, Tract 10, Lot 1 Legal description (Township, Range & Section) Lot Size 62,291 Sq. Ft. THIS APPLICATION IS FOR (® all that apply): Absorption Field ❑ Septic Tank Holding Tank ❑ Privy ❑ Private Well ❑ Water Storage ❑ Number of Bedrooms 3 THIS APPLICATION IS AN: Initial ❑ Upgrade Renewal ❑ I certify that the above information is correct. I further certify that this application is being made for a Single Family Dwelling and is in accordance with applicable Municipal Codes. Pannone (Signature of property owner or authorized agent) Date of Payment: Date of Payment: Receipt Number: 07 Ll :70 Receipt Number: (Rev. 11/05) Pannone Engineering Services, LLC P.O. Box 102954 Consulting Engineers Anchorage, Alaska, 99510 (907) 272-8218 (907) 272-8211 Fax November 26, 2007 Municipality of Anchorage Development Services Department On -Silt Water R Wastewater Program 4700 S. Bragaw Street Anchorage, Alaska 99519 Subject: Baumer S/D, Tract 10, Lot 1 EMERGENCY Septic Tank Replacement Permit Request Ladies and Gentlemen: 1 am writing to request that a permit to install a new septic tank be issued for this lot. The proposed systems will serve an existing three-bedroom house. Currently the lot is developed. The existing septic system was designed and installed for a three-bedroom house and is operating adequately for three bedrooms. The tank has collapsed and the Owner is pumping daily to keep sewage off the ground. The surrounding lots arc served by private water systems and arc over 100 feet from the proposed soil absorption system. This lot is served by private water and the well is located greater than 100 feet from the proposed system. 1. Upgrade Tank Design. a. Number of Bedrooms: 3 b. Septic Tank Size: 1,000 gallon 2. Surface Water: There is no surface water within 100 feet of the proposed system. The proposed systems will maintain at least 100 feet from all surface water and drainage ditches. 3. Topography: Lot 2 slopes to the south at approximately 1 percent based on existing contour information. The proposed installation will be located in the southern portion of the lot adjacent to the house. I could not find existing data on the installed system from the record information. I was told by the Owner that the field is a 10' by 10' by seven foot effective depth crib. It has had approximately six feet of till placed over the top. The field is operating in the last three to five percent of its useful life. I was asked by the Owner to upgrade the Geld in the spring. We will perform soils test and a Geld design in the spring. The permit will be modified then to show the upgrade Geld. The proposed installation will not affect the future development of the surrounding or existing lots. There are no wells or septic systems within 100 feet of the proposed septic location. If you have any questions or concerns, please contact me at 272-8218. Sincerely, Steven R. Pannone, P.E. Owncr/Civil Engineer Attachments: Page 1 of 1 ,41 O'RIEDNL-P Rb 3 £XIST'G JBR HOUSE ./ W v1 I £XIST'o 3 SEPTIC 3 AREA 1 3 259, £XIST'G )0008 TAN COLLAPS£D!ABANDON r5. IN PLACE PER CODE PROPOSED 1000g SEPTIC �1T TANK. INSTALL DCO. CONNECT TO EX!ST'G SYSTEM C CRIB �19 x10x r DESIGN PARAMETERS i 4 3 NO. BEDROOM: 3 TANK SIZE: 1,000 gallon CONNECT TO EXISVC FIELD A L&i=-r OFAtg1j) PANNONE ENG SVC, LLC REVISED Date f r Sf () ig,•' y / P.O. BOX 102954 ANCHORAGE, AK 99510 PHONE (907) 272-8218 FAX (907) 272-8211 „ /26/07 n t'n Scale 1'e 50' P.I.D. NO Bauder S/D, Tr 10, Lt I /'Steven R. P'orin` ne' j Patrick Baurter 50-611-1 CE 8149 24212 O'Riender Rcl PERMIT N0. � s ] � /26/0,7. •' ,� 1 (I�orFssa=�= Eagle River, AK 99577 DESIGN swo7xxxx sheet \���� (907 ) PLAN 1 or 2