Loading...
HomeMy WebLinkAboutPARK HILLS #1 BLK 2 LT 1Onsite File #017-142-14 Swale no longer required. 15.65 allows AWWTS to be 50 ft from surface water. Jun 24 22 10:07p Anchorage Well & Pump Ser 9072430742 p.1 MUNICIPALITY OF ANCHORAGE Development Services DepartmentQ 1 Phone: 907-343-7904 On -Site Water & Wastewater Section t Fax: 907-343-7997 Pump Installation Log Well Drilling Permit Number: Parcel Identification Number: 017 142 14 Date of Issue: - - Legal Description Block Lot Property Owner Name & Address: FRANCIONE JOHN M & PAMELA J PARK HILLS#1 2 1 14621 PARK HILLS DRIVE ANCHORAGE, AK 99516 Pump Installation Date: e6 - 16 - 2022 Pump Intake Depth Below Top or Well Casing: " Pump Manufacturer's Name: AYMCDONALD Pump Model: 6622-059/23050V3 Pump Size: '50 hp Pitless Adapter Burial Depth: 10 I Pitless Adapter Manufacturer's Name: I Pitless Adapter Installer: feet feet MARTINSEN Well Disinfected Upon Completion? I\Yes ❑ No i Method of Disinfection: PELLETS Comments: Pump Installer Name: _ ANCHORAGE WELL & PUMP SERVICE Company: 7640 KING STREET ANCHORAGE, AK 99518 Mailing Address: 907-243-0740 City: State: Zip: Municipality of Anchorage Development Services Department Building Safety Division ,. On-Site Water and Wastewater Program, 4700 Bragaw St. P.O. Box 196650 Anchorage, AK 99519-6650 Page I of Z www ci.anchorage.ak us (907) 3417904 ON-SITE WASTEWATER DISPOSAL SYSTEM AND/OR WELL INSPECTION REPORT Permit Number: SUO O 70 3 13 PID Number: Of 7- r Y 2- l y Nam. H F k lion C-h e i1L I,. i Wastewater System: ❑ New ® Upgrade Agaetf 15162! park jfFfl� Or'la-C ABSORPTION FIELD P'o"• Nu M sowoomt, 3 Ir- 76S'2. g D Deep Tglrll 19 S1ul1 Tr«m D aW O mo 13 Dpvr LEGAL DESCRIPTION Sod Rung 3.0 TOM Doi Mom mg." glee .p 2 SW n,sm Ll Par4 Hall 11t/ GPDIFtl Depth to p" boaom can anger, pada .!. y Ft. Gran« dean beneath pp. TowlWp Range Seam 2.7 FI. TO added audr."" Pld• 0.7 Fi Crar«L«pm O FI. 38 Ft Well: Ewrr ❑ New ❑ Upgrade Z'a ""n0" s Num aono a orrnw wt-een:net Cr4W:atmlPngr A,a CI lol«D.pm COW 10 FL Toma.Pgn«aa 1 �- FI P"Mal .&I P—�O ry FI. FI Drnl« Dlle DrnNd $1lIK W««larN i 90 Fla YIt1aWr F•- r Dom n)tYyde� Ft A�' �ZlJ �07 Y. Pure S« « Catep M•grx Actor• Crocq GPM Ft. Ft TANK SEPARATION DISTANCES ❑ Septic ❑ Holding ❑ S T.E.P. U6,C44 /-t>,c Ii7Other: To Septic ADsorptlon Lit From Tank Field Station Holding ubuuPnvate Tank Sewer Line •T.. ap«aly A-r1CA0r e %eA k ISOGG« WON tor' Up, e a 11ce .. I 2,rF AMt.MkC / Nunlp.r q Carolnm«xt 2 S•rtxe w«« 6 j'' 66 a bra — LIFT STATION La OneO e / rs' 6a F _ s• N. 4. G" aau« p rin tO – _Tf%k1,law/ Fou._rm 1 O • Z01 1d 1 _ Punp on, n •Pwnp W M=« n H•gn ..to, ««m ie Corn Dr«n .- - ^ Pump Moxa 6 Agd•t Erarlrrl in oocumt P.nonnM OF f•i• G. R.,4" s I a F1 leen l .. 4 d- Cile.0 s !'+IM /�;., BENCH MARK - a•a 41rl: afir un o4anmoo( er' e"col Luauon arq D•aongm Ta &F toms --a0 CA eCArF •a1. cud/i a.. re-0-wat A7 au•rm•d �•.•;.on lr40rAIt a� 4C"tc'k /cx, OFI C rIn iIA C i yl TccSVr rl t f.w Engineer's Stamp Inspections performed by: r,=(a/Llap -"rel, Sue Dates: 1" 12/Z l a7 2nd 12 /S/ �7 ` ` ; • •A4 a„B� Development Services Department Approval Conditional Approval Date: %;'49 11`:� .r O N ........... ............ . THEODOPE F. MOORE�� Reviewed and approved b : 7 �.� V'Oy PP Y CE-3587 •XL`r Y'I ''-•' f �¢'� ``� i/ Date: v IRn wwl .., �y/`,^� '^Ylv -L- ?i.rt:�s,S' PERMI 9 I• i • 1/ N //11 IIINIII IIIIIIINI I/II/III/II N/IIIII//II IIIII///IIIII iNIIIII/II/III •• :':::/SSSSS�:I 17-142-14 NIN�III SSI SI% •IIIISI • •IIIII • NI/II/I SI//I/III 'NIIII/I IINIII •/IIIII 'ss ss <ss • • • PAGE 2OF2 SWING TIES -TBM - FROM: «„ «H.. TO: "ADVANTEX" TO S.IR=M TREATMENT TANK �i�� 38 -FOOT LONG x 5 -FOOT WIDE SOIL ABSORPTION DRAINFIELD w. 0.7. GVL. 81.0' SAND UNDER PIPE COR. "A• COR. "B' --- FDN. C.O. "C" 3.5' 43' a S.T. C.O. "D" 12' 47.5' o CTR. POD "E" 15' 50.5' m TANK M.H. "F" 19' 53.5' T DRFLD C.O. "G" 27' 42' a DRFLD M.T. "H" _42.5' ---39'— N OR -F D -c. " 62.5' 48' ���/1YPARAIIEI QP, �3r.eePLAN VIEW ��� PPROX�MATE w"G l'_t�' AtltCSCALE: 1" = 30' ........•Ni•..� 7.�........� .. c FILTER POD "" 000RS F. IdOOR: j J7 C:-35EJ �1Y' 6'" dap FINAL GRADE ELEV. 93.5'Fl –� ,r/I/Ui1���• f/ :, r... Z2.0. SOIL COVER /-2" RIGID INSULATION f PROFILE VIEW NOT TO SCALE -------------------------- I/ .'1A' FILTER SAND ELEV. 90 T : I ELEV. 89.1' 4" DIA. D-3034 INV. 90.8' THROUGHOUT 0.7' SEWER GRAVEL BELOW DIST. PIPE 38 -FOOT LONG x 5 -FOOT WIDE SOIL ABSORPTION DRAINFIELD w. 0.7. GVL. 8 1.0' SAND UNDER 1500 -GALLON "ADVANTEX" M' " TREATMENT TANK INLET PIPE INV. 89.5' BOTTOM T.H. #1 M.T. ELEV. 79.1' - WATER @ 83.8' 11/8/07 " f PROFILE VIEW NOT TO SCALE -------------------------- I/ .'1A' FILTER SAND ELEV. 90 T : I ELEV. 89.1' 4" DIA. D-3034 INV. 90.8' THROUGHOUT 0.7' SEWER GRAVEL BELOW DIST. PIPE 38 -FOOT LONG x 5 -FOOT WIDE SOIL ABSORPTION DRAINFIELD w. 0.7. GVL. 8 1.0' SAND UNDER wa t el: nl�. !M. b0/ U[ 4bw 12/10/07 10:33a P. 001 eYvq' `t' EMPF.C77ONREPORT MUNICIPALITY OF ANCII0IL4GE -- BUILDING SAFETY DI VISION 4700 SOUTH NRAGAW STREXI' /,NNPh.'l.T/O,V.V_Voice: (907) 343-8300 Fax: (907) Zd9-777J �wrn munior�+?fSDgiupcc6��ns.cfm NAAIr: - .--.. _.. _ PERAr7T7Y:: C0.'NPAVY C:_- Z)-I� Jam' ['�—� CVSPCCrDAM - --- — PHONT 0 PdONT it PHONE 9 .+nnRe.�e ��� �._ •�ii1Z K F•i � L.Y--S _tnT. _ Ln.vc:Kr SUUDIiTS'(UN. GRID# -_ COMMEN'IN UP L)W.rrIO,vS: I'YPE or IMP£CTIVV: _. (OM.+lT N7s: (MR Ev.vpEc.'TvR V..CL• On)) G -TI~ I C A - t, F �l 1:1 L Inn�rto nA+rr..� VA1T•.: 0 MUNICIPALITY OF ANCHOR4GE Development Services Department On -Silo Water 8 Wastewater Program 4700 South Bragaw Street P.O. Box 196650, Anchorage, AK 99519-6650 (907) 343-7904 ON-SITE WASTEWATER DISPOSAL SYSTEM PERMIT Upgrade Permit Number: SW070313 Legal Description: PARK HILLS #1 BLK 2 LT 1 Design Engineer: 0019 FLATTOP TECHNICAL SERVICES Owner Name: MIKE RONCHETTI Owner Address: 14621 PARK HILLS DR ANCHORAGEGE , AK 99516 - Date Issued: Nov 26, 2007 Expiration Date: Nov 25, 2008 Parcel ID: 017-142-14 Site Address: 014621 PARK HILLS DR Lot Size: 39932 SO. FT. Total Bedrooms: 3 Permit Bedrooms: 3 This permit is for the construction of. ❑✓ Disposal Field Q Septic Tank ❑ Holding Tank ❑ Privy ❑ Private Well ❑ Water Storage All construction must be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal Code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations ( 18AAC72 ) and Drinking Water Regulations ( 18AAC80 ). 3. The engineer must notify DSD at least 2 hours prior to each inspection. Provide notification by calling (907) 343-7904 ( 24 hours ). ( Not required for a Water Supply Permit only ). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must be either: A. Open and closed on the same day. B. Covered, sealed, and heated to prevent freezing. Received By: Date: ///3 v /o Issued By: _[� GU(r/�ir/.�/rr,/ Date:O Municipality of Anchorage -�1 Development Services Department Building Safety Division On -Site Water and Wastewater Program 7t *ti 4700 Bragaw Street P.O. Box 196650 Anchorage, Alaska 99519-6650 www.muni.org/onsite (907) 343-7904 ON-SITE SEWER/WELL PERMIT APPLICATION FOR A SINGLE FAMILY DWELLING Parcell.D. 6jq_lL4a- /q .ash Property owner(s) Mr kL 8 P c,43� Ff ; Day phone F^YL / Mailing address lYt; 2l LtF-k- 8,lG DeltZ MAc�, Zip Code 9`75 -ll Site address xe_ .e Zip Code Legal description (Sub'd., Block & Lot) Lot 1. /y-i/lr C /A -Al Legal description (Township, Range & Section) Lot Size ��q "I 32- Sq. Ft. THIS APPLICATION IS FOR (Z all that apply): Absorption Field 19 Septic Tank 19 Holding Tank O Privy El Private Well Water Storage Number of Bedrooms 3 THIS APPLICATION IS AN: Initial Upgrade Renewal ❑ I certify that the above information is correct. I further certify that this application is being made for a Single Family Dwelling and is in accordance with applicable Municipal Codes. (Signature of property owner or authorized agent) Permit/Rush Fees: `1160 Waiver Fees: —I rS'D Date of Payment: 11 /l3 /07 Date of Payment: 11 /13 /0 7 Receipt Number. /6141/4'q Receipt Number. (Rev. 11/05) o � Mimicipality of Anchorage Y,3r 1'.(). nktx 19(NM • Anchnrn(;c, Alaslm ffiAi19.6GiO • 47(N)1;6uorc Poxul 01,.. / ()fli(v: (SNYI) 3()4.9101 • Pax: ((X)7) 343.8200 htgr.//aiwtnuml.org Mayor Mark Begich I)cvclopment Sen3ces Depart);netiit November 26, 2007 Ted Moore, P.E. Flattop Technical Services 14530 Echo Street Anchorage, AK 99577 Subject: Waiver Request for Park Ilills #1, B2 Ll Waiver Request WR#: 070063 Parcel ID # 017-142-14 SW070313 Dear Ted Moore, P.E.: Nov c o� A ' n Departr Your request for a waiver of the required 100 feet horizontal separation from the absorption field and septic tank to the surface water has been approved. The approved separation distance is 60.0 feet. This waiver approval applies to the existing absorption field and septic tank to surface water separation only. Any future upgrade to the on-site wastewater disposal system will require all separation distances be met or another approval from this department. If there are any further concerns or questions regarding this waiver, please call our office at 343-7904. Sincerely, N� Deb Wockenfuss Civil Engineer On -Site Water R Wastewater Program Conlmuniti/, Security, Prosperity Municipality of Anchorage Development Services Department • Building Safety Division On -Site Water and Wastewater Program 4700 Bragaw Street P.O. Box 196650 Anchorage, AK 99519-6650 www.ci.anchoragc.ak.us (907)343-7904 Waiver Review Worksheet WR#:070063 PID#:017-142-14 HA/Permit# SW070313 Date Received: November 26, 2007 Legal Description: Park Hills #1, B2 Ll Engineer: Ted Moore, P.E. Flattop Technical Services 14530 Echo Street Anchorage, AK 99577 Applicant: Mike Ronchetti Waiver Requested: 60' from tank and disposal field to surface water Criteria: Geology A. Water Table B. Soil Sorption C. Permeability D. Water Table Gradient E. Horizontal Separation Points: Total: .......................................................................... Waiver is Granted: X Waiver is not Granted: List Conditions or Reasons for above: Cateoory III Nitrate Reducina with Remote T lemetiv system will be used Date: _11/26/07 By: Deb Wockenfuss Name of Reviewer .......................................................................... Rec#: 102149 Amount: $1]_ Q Date Paid: 11/26/2007 FLATTOP TECHNICAL SERVICES CIVIL & ENVIRONMENTAL ENGINEERING ENERGY CONSERVATION & ANALYSIS TED MOORE, P.E. 14530 ECHO CANYON ROAD PHJFAX: (907)345-1355 ANCHORAGE, AK 99516 E -Mail: tgmoore@gcl.net November 14, 2007 M.O.A. DSD — Building Safety Division On -Site Water and Wastewater Program: Attn: Deb Wockenfuss 4700 South Bragaw Street P.O. Box 19-6650 Anchorage, AK 99519-6650 Dear Ms. Wockenfuss: The following narrative with changes in bold type addresses the comments contained in your 11/14/07 Comment Sheet. By means of this letter we are requesting issuance of a permit allowing installation of an "Advantex" Advanced Treatment Wastewater Treatment System to replace the existing septic system on Lot 1, Block 2, Park Hills S/D #1. The existing septic system is operating in a surcharged condition. Documents pertaining to that system are found on your website under the erroneous legal description of Lot 1, Block 2, Park hills S/D. A revised site plan illustrating the proposed configuration and a plan and cross-section drawing and specifications are enclosed. These are being sent by US Mail in order to accommodate your insistence upon original signed documents. The plat for this subdivision designates a 100 -foot septic system setback from creek running along the southern property lines. The present septic system is located within that setback and in March of 1989 a MOA DHIIS employee determined that the designated creek was sufficiently intermittent to reapprove the system without requiring a waiver to the 100 -foot separation. Ilow•ever, at this time the creek flows relatively continuously and thus has to be categorized as surface water requiring a 100 -foot setback. Due to the location of the existing well on the lot there is no site available to construction of a septic system that meets the required setbacks; the maximum achievable separation from the creek is approximately 60 feet. Thus, I am hereby applying for a "field waiver" allowing the proposed treatment tank and residual disposal drainfield to be located as close as 60 feet from the closest edge of the creek. As I discussed with Joe Goodall on November 9'h, in order to justify granting the requested waiver we propose to install an advanced treatment wastewater tank which has been shown to produce effluent meeting secondary treatment standards. As can be seen from the enclosed design and specifications the system we are proposing to install is an "Oren co/Anchorage Tank" Advantex System with an AX -20 Filter Pod with monitoring by remote telemetry. I understand that your department has accepted this system as a Category ill System that also provides nitrate reduction. Furthermore, we propose to create a drainage swale downstream to the tank and residual disposal drainfield such that the surface flow path followed by any effluent daylighting from a failing treatment tank or residual disposal drainfield will be greater than 100 lineal feet before the flow could encounter surface water. These two factors acting in concert should provide an equivalent or higher level of surface water protection that that achieved by a conventional septic system located just over 100 feet away from the creek. Thus, the situation after construction will be an improvement over the present situation. The soils testing for a potential septic upgrade was conducted in May of 2003. The enclosed logs show sandy loam and silty sand overlying a dense sandy silt that was encountered at a depth of 6 feet. Water seeps were encountered at a depth of 11 feet and subsequent groundwater monitoring during spring breakup indicated a maximum groundwater elevation of 9'— 7" below ground level. Recent monitoring conducted during the present wet fall season indicates a seasonal high groundwater level at 8'-4" below ground level. Due to the absence of groundwater at the interface we believe that the AIL soil encountered below 6.0 feet is not impermeable and will pere at a rate of <120 minutes per inch. Nevertheless, we have designed the proposed residual disposal trench such that the bottom of the sewer gravel will be no deeper than 4.0 feet below ground level on the uphill side of the drainfield. To enhance the longevity of the system we propose to over excavate the drainfield to a depth of 5.0 feet and then place 1.0 feet of MOA filter sand under the sewer gravel. The measured percolation rate of the native silty sand material underlying the proposed drainfield is 9 minutes per inch, which according to the wastewater code can accept effluent from a Category II Advanced treatment system at 3.0 gpd/sq. ft. This 3 -bedroom residence thus requires an effective absorption area of (3 x 150)/3 = 150 square feet. The proposed 38 -foot long by 5 -foot wide soil absorption drainfield is conservatively sized with a basal area of 190 square feet. We also propose to place 12 inches of sewer gravel under the distribution pipe to allow for additional sidewall absorption equivalent to an additional 38 square feet of area. Because this is an advanced treatment system I am requesting the property owner to come in to your office in order to execute the required maintenance agreement. Since I will be out of town for a couple of weeks, please send me an e-mail if you have any questions on this submittal. I trust this resubmittal will satisfactorily resolve any lingering concerns you may have with regard to the suitability of the proposed design. If not, please send me another e-mail and I will endeavor to accommodate your further concerns. I hope that your office recognizes that the proposed residual drainfield design exceeds the minimum code requirements in a number of respects, which has been done in order to enhance the longevity and performance of the system. Sincerely, 99 Ted Moore, P.E. cc: Mike Ronchetti; (ph: 350-2529) SEPTIC ° SYSTEM ° LOT 2, BLOCK i , 1h • -w ---I ••. %44 /-� _sVDE ABANDON EXISTING / y SEPTIC TANK AND TRENCH PER CODE LOT 6 BLOCK 1 SEPTIC AREA ' LOT 1 BLOCK 2 R1 VWELL HOUSE SEPTIC ' AREA LOT 2 BLOCK 1 �\ EXISTING WELL >200'FROM \ PROPOSED UPGRADE SEPTIC \ , 100' OFFSET F_RO_M_ _ \ CREEK AS PLATTED \ LOT 1 35% T.H. BLK.1 INSTALL 1500 -GA LL ON 10% STEEL"ADVANTEX" AVG TREATMENT TANK _ INSTALL"ORENCO _ AX_ -20" FILTER POD" _ ROX.9 01'. POP' 6N�PY� CREEICFOL�O'NS PPP LOT 8, BLOCK 2 EXISTING WELL >200'FROM PROPOSED UPGRADE SEPTIC Gr A4 � .rrti�y. • • �: ^0 FY:'nr9Tr1C`� ter, -.THEODORE F. MOORE 5509 r_ r_ _ .inti ,—A § \ \ CONSTRUCT 38 -FOOT LONG . x 5 -FOOT WIDE SOIL ABS DRAIN D w.1.0' SAND & 1.0' GRAVEL BELOW DISTRIBUTION PIPE ------------------------ NO CUT BANK AT STREAM CONSTRUCT DRAINAGE SWALE SUCH THAT SHORTEST SURFACE FLOW PATH FROM DRAINFIELD TO CREEK IS > 100' PORTION SECTION 34, T12N, R3W NO WELL AND SEPTIC RECORDS ON MUNI DATABASE EXISTING WELL IS >200 FEET FROM PROP. SEPTIC UPGRADE LOT 1, BLOCK 2, PARK HILLS SID #1 SEPTIC SYSTEM UPGRADE SITE PLAN FLATTOP TECI INICAL SERVICES I'1 INCH = 50 FEET 14530 ECI IO CANYON ROAD DRAWN BY TFM ANCHORAGE, ALASKA 99516 1 REV. NOV. 2007 NOTE: THIS IS NOT A SURVEYED PLAT. ALL LOCATIONS SHOWN ARE APPROXIMATE. 4• WASTE LINE FROM EXISTING FOUNDATION C.O. 14 INSTALL"ORENCO" "AX -20" FILTER POD 1463 MONITOR ORIGINAL INSTALL 1500 -GALLON EPDXY-COATED STEEL "ADVANTEX" TREATMENT TANK 3" PVC OR 4" D-3034 DISCHARGE LINE FROM FLOW SPLITTER 38 PLAN VIEW SCALE: 1" = 10' 10Y. AVERAGE SLOPE FILTER FABRIC 4" DIA. F-810 1/2"- 2 1/2" SEWER GVL. _ (1.0' BELOW INV.) 1.0' MOA FILTER SAND - BOTTOM OF EXCAVATION -41..A., C.O. OR TUBE TION PIPE 5 CONSTRUCT 38 -FOOT LONG x 5' WIDE RESIDUAL DISPOSAL DRAINFIELD w. 1.0' FILTER SAND 8 1.0' SEWER GRAVEL BELOW DISTRIBUTION PIPE. TOP OF SAND SHALL BE AT 4.0' BELOW GROUND LEVEL ON UPHILL SIDE OF DRAINFIELD 3 CROSS-SECTION "A - All •' SCALE: 1" = 5' A' 40 .- 4''••;.f' C th '�- •�' � �• LOT 1, BLOCK 2, PARK IIILLS S/D #1 SEPTIC SYSTEM UPGRADE I.' I . TRSCDC": F A•OCIOR�CRI PLAN AND CROSS-SECTION `; /�?T�!' FLATTOP TECIIN[CAL SERVICES SCALE: AS SIIONN �• , ' .':;-..•. •r7, `;Q' 14530 ECI IO CANYON ROAD DRAWN BY: TFM ANCIIORAGE, AK, 99516 i NOVEMBER, 2007 FLATTOP TECHNICAL SERVICES 14530 ECHO ST. ANCHORAGE, ALASKA 99516 TEST HOLE # 1 I SOILS LOG — PERCOLATION TEST LEGAL DESCRIPTION:__ Lotl. Block 2, Park Hills S/D _# DATE PERFORMED: __ _May 9, 2003 (Updated Nov. 2007),_ Mike Ronchetti...... __. GM (fill material) Pt. SM Reddish sandy loam SM Gray silty sand Dry, loose, fine SLOPE _ /EX17STlN1,G SITE PLAN DVBDRM i HOUSE 34 <%DECK—�1° #1 33 YSTEM %` l r j 0% ML Gray gravelly sandy silt o ! Dense, hard digging I 120/o Sidewalls do not smear Depth to Groundwater Date Water seeps-__ - Seeps @ 11.0' `_5/9/03 C Water9'-.7” 15/16/03 __- f Water �Sa 9' - 9" SLOPE 520/03 'Water@8'-1'- Time (minutes) l Reading B.H. ---- i L_519�_12"Presoak ----•------�_._ i Date Reading 0% Net Time Percometer I Net Drop p i i Date Reading Clock Net Time Percometer I Net Drop p Time (minutes) l Reading (inches) L_519�_12"Presoak ----•------�_._ 1.12" resoak __— _ ._27.1)2_-- 27 1/2 I Add water S start 12:17:20 23 3l8 } Add water. - —1_ ---- _124720 -__12:47:45.: I 30 ___�-195/8„- _ _ L _33/4 #2_,_____,__1;17:45,_ 30 .233/8 _1911/16.,. 311/16 Add water 1;1815 j 239/16 .i I 30 r - 1915/16 } _3518 _..� PERCOLATION RATE _ _g (minutestiinch) PERC HOLE DIAMETER TEST RUN BETWEEN —5.5_.F'T AND --6.0 __Fr COMMENTS: -.Advanced treatment soil absorption system should be sized at 3.0 gpd/sq. ft. (minimum). _- PERFORMED BY FLATTOP TECHNICAL SERVICES. 1 _ 1Z� CERTIFY THAT THIS TEST WAS PERFORMED IN ACCORDANCE WITH ALLSTATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE. DATE: ; - -­ ---- --- ------ TEST HOLE # la �4 =�•i t. Yl FLATTOP TECHNICAL SERVICES 14530 ECHO ST. R' +; • .•' �.?� ANCHORAGE, ALASKA 99516 Z. •r'',,.' Soy 0 SOILS LOG - PERCOLATION TEST •••................ •••••••tw•••••1 LEGAL DESCRIPTION:__ _Lot 1, Block 2, Park Hills SID _-M)____.___. _ DATE PERFORMED: _May 9, 2003 (Updated Nov., 2007) .. PERFORMED FOR: ----..-.Mike Ronchettl GM (fill material) Pt. SM Reddish sandy loam SM Gray silty sand Dry, loose, fine SLOPE •. THEOJO?: F. A:OORE � A CE -3569 ' 4 e� 4 � �A "-• Ste. SITE PLAN /EX17STINIG DRIVE-BDRM HOUSE 34DECK -T.H`� / 33 SYSTEM ` IAF I ML Gray gravelly sandy silt / 20% i Dense, hard digging i Sidewalls do not smear Depth to Groundwater Date ' Water seeps �eps @ 11.0' -j Se_519/03 Waterna 9'-7 5/16/03 _SLOPE Water PPaaSs 9'-9” 5/20/03 f Water@8'_4"-_11/8/07 r- --. B.H. - -- - --- - ------ i 0% I I Date Reading Clock Net Time Percwmeter l Net Drop ' I •. THEOJO?: F. A:OORE � A CE -3569 ' 4 e� 4 � �A "-• Ste. SITE PLAN /EX17STINIG DRIVE-BDRM HOUSE 34DECK -T.H`� / 33 SYSTEM ` IAF I ML Gray gravelly sandy silt / 20% i Dense, hard digging i Sidewalls do not smear Depth to Groundwater Date ' Water seeps �eps @ 11.0' -j Se_519/03 Waterna 9'-7 5/16/03 _SLOPE Water PPaaSs 9'-9” 5/20/03 f Water@8'_4"-_11/8/07 r- --. B.H. - -- - --- - ------ i 0% I I Date Reading Clock Net Time Percwmeter l Net Drop Time (minutes) Reading I (inches) 5/9=? -12 .Presoak _ __ 31 ._ 1 ! 12 31 I ( ! Add Add water & start- --112:0410_ _ 27 - - -._..__#1__- ._ 121410-1- 10 _._. __.211/4 I — . Add water___ ..__12:15:45 - _ ._ _ - ; 27 ..53/4 - #2 -- 12:25:45 , 10_21 3/8 Add water _; --12:26:15 _ _ _. ( _..-#3 123615 --_ 10 ._. _217116 -_59/16 _ r h PERCOLATION RATE 2 (minuteslinch) PERC HOLE DIAMETER-&'- TEST IAMETER&'TEST RUN BETWEEN__ 3.0 -„_ FTAND___3.5 .. , FT COMMENTS:.- 2nd pert test conducted adjacent to same test hole to determine percolation rate of upper SM stratum... . PERFORMED BY FLATTOP TECHNICAL SERVICES. I T�_ %'1�[G.c� - CERTIFY THAT THIS TEST WAS PERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE. DATE: I r / �,�_ / v 7 _ - tEYattop ?echnicarservices 14530 Echo Street, Anchorage, AX 99516 (Phone (907) 345-13S5 Lot 1, Block 2, Park hills S/D #1 14621 Park Hills Drive Wastewater disposal system upgrade Specifications 1.0 General: 1.1 The scope of the project consists of installing an "Advantex" advanced treatment system using a 1500 -gallon epoxy -coated steel Anchorage tank with a single AX -20 Advantex treatment pod. The filtered effluent is discharged into a 38 -foot long by 5 -foot wide residual absorption drainfield with 12 inches of filter sand and 12 inches of server gravel below the distribution pipe. 1.2 Construction shall be as depicted on the approved site plan and design drawings. Minor deviations from these drawings may be allowed or required by the engineer conducting the inspections. All construction procedures and material specifications shall conform to Municipal and State requirements. All separation distances shall be in conformance with Municipal requirements, unless specifically waived. A waiver has been requested allowing the wastewater system components to be as close as 60 feet from surface water in the creek along the south boundary of the lot. 1.3 The contractor shall be responsible to obtain any necessary utility locates, and to work around any buried utilities. 1.4 The contractor shall provide adequate cover material and rough grading over all system components to ensure that proper drainage is achieved ailer settlement and that there are no residual depressions. insofar as possible the contractor shall minimize damage to trees and existing lawn areas. 1.5 Unless specifically agreed otherwise, the homeowner shall be responsible for finish grading after the soil is compacted, as well as placement of topsoil and reseeding all areas disturbed by the construction. 2.0 "Advantex" AX -20 Advanced Treatment System: 2.1 The "Advantex" treatment unit major components include (1) a 1500 -gallon, 2 -compartment epoxy -coated steel tank and (2) a single AX -20 filter pod. All components shall be Municipally approved and shall be set level on undisturbed soil and backfilled in accordance with Municipal requirements as well as Orenco's and the supplier's instructions. 2.2 All pipe connections to the tank shall be equipped with waterproof mechanical couplings. The waste line from the residence to the tank shall have a minimum slope of 1/4"' per foot, and the waste line between the splitter valve and the drainfield shall have a minimum slope of 1/8" per foot. 2.3 The contractor shall be responsible to obtain the necessary Municipal electric permit and inspection, and shall provide a copy of the electrical inspector's report to the engineer overseeing the construction of the wastewater disposal system. 2.4 The second compartment of the tank shall be equipped with a watertight, insulated manhole riser and cover extending a minimum of 6" above final grade with positive surface drainage away from the manhole. The contractor shall be responsible for determining the necessary length of the manhole riser, and for properly positioning the Recirculating Splitter Valve (RSV) in the riser. 2.5 The control and alarm floats shall be set at the elevations specified by the supplier, and their proper operations shall be verified by the contractor. 2.6 The treatment unit shall be set up with a "VeriComm" remote monitoring system as supplied by the distributor, and the control panel for the unit shall be mounted at an approved location. 3.0 Residual soil absorption system: 3.1 The soil absorption system shall be constructed by excavating a 38 -foot long drainfield to a depth of no more than 5.0 feet below ground level. The long axis of the drainfield shall be parallel to a natural contour of the ground and the downhill side of the drainfield shall be no closer than 60 feet front the north side of the creek. 3.2 The bottom of the excavation shall be level. A total of 1.0 feet of M.O.A. filter sand (<4% passing the #100 sieve) and 1.5 feet of sewer gravel shall be placed in the trench excavation with the perforated distribution pipe laid level such that the pipe invert is 12 inches above the bottom of the sewer gravel. Sewer gravel shall be 0.5" - 2.5" washed gravel. The distribution pipe shall be 4" diameter f-810 perforated pipe. 3.3 The monitor tube shall be of 4" diameter and installed in the location shown on the design drawings. The portion of the monitor tube extending through the sewer gravel shall be perforated. 3.4 Approved filter fabric shall be placed over the entire top surface of the sewer gravel. 3.5 The top surface of the cover material shall be raised a minimum of 6 inches higher than the surrounding terrain to allow for subsequent settlement, and shall be graded to smooth contours. Fill slopes shall be no steeper than 3:1, and shall be extended out until they intersect natural ground. 3.6 The contractor shall create a shallow drainage srvale parallel to the creek on the down/ill! side of the drainfield such that the shortest surface flow path bethveen the tank or drainfield and the creek is greater than 100 feet it: length. 3.7 Unless specifically agreed otherwise the homeowner shall be responsible for arranging to have the site finish graded after the backfill material has stabilized, and for placement of adequate topsoil and seeding to promote rapid revegetation of all areas disturbed by the construction. 4.0 Inspections: 4.1 A minimum of 5 engineering inspections will be required during the course of the project: (1) initial stakeout with the contractor to establish the location of the system and to discuss the plans, specifications and construction procedures, (2) after the native material has been excavated to expose the infiltrative surface to ensure that it is level and at the right elevation, and conforms with the soil test information, (3) after the sand filter material has been placed, (4) after the sewer gravel is in place and the distribution pipe has been laid and connected up to the septic tank, but prior to placement of filter fabric, and (5) after rough backfill and grading is complete. The "Advantex" treatment unit requires one inspection after the tank is set level and the piping connected, but prior to backfill. This inspection may be incorporated with any of the above inspections. 4.2 The installer shall coordinate the timing of the inspections with the engineer sufficiently far in advance to ensure the availability of the engineer.  MUNICIPALITY OF ANCHORAGE DEPARTNII~NT OF HEALTH & ENVIRONMENTAL PROTE~CTiON ENVIRONMENTAL ENGINEERING DIVISION 825 L Street- Anchorage, Alaska 99501 Telephone 264-4720 ON-SITE SEWAGE DISPOSAL SYSTEM AND/OR WELl INSPECTION RI:PORT NAME MAILING ADDRESS LEGAL DESCRIPTION ' · DROOMS 2z DISTANCE TO: Well IO~ ~ ~O~ ~ Manufacturer No, of compartments ~ ~ ~ Materi~ .~ ~ Liq. capacity in gallons ~00~ IF HOMEMADE: Inside length Width Liquid dept~ ~ ~ DISTANCE TO: Well Dwelling ~ PERMIT NO, O ~ ~ Manufacturer Material Liquid capacity in gaNons ~ Well Foundation Nearest lot line PERMIT NO, No, of lines ~ Length ~ ~ch fine Total length of lines Trench Distance between Pines Top of tile to finish grade~_I ~/ ~-~ Material beneath tile Total effective absorpt;on area Length Width ~ Depth PERMIT NO. ~ N Type of crib Crib diameter ~ ~ Crib depth Total effective absorption area ~ Well DISTANCE TO: Building foundation Nearest lot line ~ Class Depth Driller Distance to lot line PERMIT NO, ~ DISTANCE TO: Building foundation Sewer line Septic tank Absorption area(s) OTHER PIPE MATERIALS ~ ~ SOIL TEST RATING INSTALLER REMARKS ~ / / APPROVED DATE LEGAL 72-013 (Rev, 3/78) BOX ~69, STAR I~OUT~ .~ -~(~ItORA(~E~ ALASKA SIX INCH WATER WELL DRILLED AND CASED OUT TO THE DEPTH OF DRILLED at the rATE OF :~9~, 00, PEr FOOT. PROPERTY OWNEr LOCATION OF WELL SITB WELL LOG: 0 .... 22' S~.,. q~.~eZ. 777 COST INCLUDES ALL LABOR AND MATERIAL FOR COMPLF_'fION OF SAID DRILLING. WRITE CHECK PAYABLE TO RAMPART DRILLING works for THE SUM Of '~9'~9~00 THANK YOU VERY MUCH. BERNIE CLAUS OF RAMPART DRILLING WORKS SERVICE CHARGE OF 1~,% PER MONTH WILL Be ASSESSED O~' b~ F'ERHI T N0. FtF'F'L I CRN'F LOCRT 1 ON LEGAL STEVE F'IZR LIB.'-:' F'RRK HILLS SRR 4 .... --", ANCHORAGE :~L4.5E~7 ~,~.~_ =- LOT SIZE 999999 S6!URRE FEET TVF'E OF SOIL RE=SORF'TION S'¢STEM IS: TRERC:FI MRF-',"IMUN NUMBER OF BEE:,ROOM'-] = :: SOIL RATING (SL.] FT,. E,F..',= ±90 THE REL-]LIRED SIZE OF ]'FIE SOIL ABSORPTION SVSTEM IS: THE LENGTH [.',IMENSION IS THE LENGTH (IN FEET) OF THE TRENCH OR [:'RRINFIEL[:,. THE [:'EPTH OF R TRENCH CF.' PIT IS THE [:'ISTRNCE BETHEEN THE SURFACE OF THE GF.'3JND AND THE BOTTOM OF THE EXRR\,'FJTIF~N (IN FEET). THERE IS NO SET 1.4I[:,TH FOR TF. ENCHES. THE GRR\,'EL DEPTH IS THE MINIMUM [:,EPTH OF GRA\,'EL BETWEEN THE OUTFRLL PIPE RND THE BOTTAM OF THE E,.,bR,HTI_N (IN FEET). PERMIT APPLICANT HAS THE RESPONSIE:ILiTV TO INFORM THIS DEPARTMENT DURING THE INSTALLA'rION IN=,FE_.TIuNb OF FINV HELLS R[:,JACENT TO THIS PROF'ERTV AN[:, THE NUME,'ER OF RESIDENCES THAT THE HELL [,.IILL SERVE. TI.--tC~ ':: '---:---: ::' :[ i%~SF'EC:T :[ C~ [%1___'-: RF-:E E:E L--:.~L~ Z BR~]:KFILLING OF RN'¢ SVS]'EM HITHOUT FINAL INSF'ECTIOH RN[:, ~F'P~'A',,~ ........ ',, ,~- THIS [:'EF'RRTMENT 1.4ILL BE SUBJECT TO PROSECUTION. PIINIMUM [-"ISTRNCE BETHEEH R HELL RN[:, RHV ON-SITE SEHRGE [.',ISF'C,_=;RL S'¢STEM IS ±E~O FEET FCA R PRIVRTE HELL OF.: ±5F~ TO 200 FEET FROM R PUBLIC HELL [:'EPEN[:,ING UPON THE TVF'E OF PUBLIC HELL MINIMUH [:,ISTRNCE FRJM R F'RIVRTE [4ELL TO R PRIVATE SEWER LINE IS ':'=; FEET AHD TO R COMMLINIT'¢ SE[4ER LINE IS 75 FEET. ' .... 1.4ELL LOGS RRE RE6!UIRE[:, RN[:, MUST BE RETLRNE[:, TO THE [:'EPRF.'.TMENT HITHIN _--.':A OF THE [4ELL COMPLETIOH. - OTHER RE-c,~UIREMENTS MRV RPPL'¢. SPECIFICATIONS RN[:, F:FIHC;TF.'UCTION [:'IAGF.:RMS ARE RVRILRE:LE TO INSURE FR_FER IHSTALLRTION. PEE:~'.'i I -f' E.--.F Z [;:-:ES [:'EC:EI"JBEF:.- _-----:dl _. -'] I CERTIFV THRT ±: i RH FAMILIAR [4ITH THE REEqUIF'.EI"JENTS FOR OH-SITE SEHERS RN[:, [4ELLS RS SET FORTH B'¢ THE FIUNIF:IF'ALITV OF ANCHORAGE. .2- I HILL INSTALL THE '--"~ -,~:,TEM IN RCCOF.'.[:'RNCE ~,.IITH THE CEE)ES. 3: I UN[:,ERSTRND THRT THE ON-SITE SE~4ER SVSTEM MR'¢ REE.!UIRE ENLARGEMENT IF THE F.'.ESI[.',ENCE IS REMO[:,ELE[:, TO INCLUDE MORE THAN 2'. BE[:,F.!OOML-~. \,'4. 0 Ar( Civil and. Geotechnical Engineering Consu' ts A.W. Murfitt Compa__ny_ 8010 King St. ~:~$<~(~)~i~ · Anchorage, Alaska 99502 Telephone 349-7531/7533 Iqarch 3, 1983 Arctic Resodrces Drilling, Inc. 6361Nielson Way, Suite 101 Anchorage, Alaska 99502 Attention: Ray Morris Vice President Re: Borehole location error regarding lots 1 and 2, Block 2, Park Hills Subdivision, ~ncI~orage, aska. Dear Ray, On Hatch 31 1983, while walking Lot 1 of the above .,~=~ ~ ~ division, /.ir. ~ceve Pisa showed me two PVC standpipes installed in a previously drilled test hole and percolation test hole at iJ]is ..}{e. Sc=~e s concern was that the test hole was actually Test Hole 7A on c~,_ plat to be located on Lot 2 of this subdivision and that he might not need to re-drill the site and perform percolation tests. After 1 ~ '' o:ac;ng [he approximate lot lines for Lots 1,2, and 3, I walked Lot 2 in an aa.,,:mpc to ocace any previously drilled borehole in the vicinity of Test F;ole 7A as shown on the plat. I could not find any borehole or ~:VC ~'~'~n~,i ~ = drilled =~ ..... " ....p pe for this t~s, hole on Lot 2. As the previously ~.,:s~ ,o~es w:~re drilled prior to road c ~ ' on the la~,d, I ..... ~ onscruct]on and improvements . ,~1 ~,,a~ an e~'~'or :T~a3., ?~ve ]~:en made in the original location of =~' L;]iS test ;o]e. Upon locating thc and 2, I feel that Test note FA is ~c~oally ocated on lot 1 of this subm]N]s]on. The approximate location of Test Hole 7A is shown on the attached Plate 1. Test Hole 7A was drilled on 3-23-82 and a percolation test was performed on 3-30-82 by "others" (per attached Municipality of Anchorage Soils log and Percolation Test). I measured the depth of the perforated 4--inch diameter PVC casing -For the percolation test and found it to be approximately 76-inches in depth with a 6 3/4 inch stick-up above §round as indicated on the soils log. I, also, measured the depth of the I 1/2 inch diameter PVC slotted casing installed in the test hole and found the depth to be 14.5 feet, however, the probe indicated that the PVC has "silted in" and that the actual installed depth cannot A~ctic Resources Drilling, Inc. March 3, 1983 be determined. It is my opinion that the location of Test ltole 7A as indicated on the plat is incorrect and should be as indicated on the attached Plate 1. I, also, feel that the borehole soils log and percolation test results performed in Test Hole 7A should satisify the requirements of the Municipality of Anchorage, Department of Health and El~viror~mental Protection For lot 1 of this site. Should you have any questions regarding this matter, olease do not esltabe to CO~ltact us. Yours truly, A. W. l,iLIRFIl-i' COMPANY ,Mffrey hi. Aires S,_:nior Engineering Geologist JMA/dt 0 £/ PERFORMED FOR:.. LEGAL DESCRIPTION: 1 2 3 4 5 6 7 8 9 10 \'~MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH AND ENVIRONMENTAL PROTECTION 825 L. Street, Anchorage, Alaska 99501 2644720 SOILS LOG-- PERCOLATION TEST SLOPE [] .~ SOILS LOG [] PERCOLATION TEST _ DATE PERFORMED:__3 o ~. ~ ~. SITE PLAN 11 12 13 14 15 16 17 18 19 20.-- OMMENTS WAS GROUND WATER ENCOUNTERED? IF YES, AT WHAT .DEPTH? Reading Date I PERCOLATION RATE~ Time 0 S Net Time O I:o& Depth to Water (mlnutes/~nchJ TEST RUN BETWEEN .~"'/4~- FT AND ,J~'"'~/4 FT Net Drop ERFORMED BY: .CERTIFIED BY: DATE:__. ?-o0a (6/79j ~ ~ i4£' 84 • Municipality of Anchorage !�. On -Site Water and Wastewater Program 4 (907) 3`1'3-- 904 $ A E T Y - CERTIFICATE OF ON-SITE SYSTEMS APPROVAL Parcel i. D. , Of 7- 1Y 2- I y Expiration Date: 1. GENERAL INFORMATION Complete legal description a t 1y Q /ac 2 P""4, k lflllr #*i Location (site address) + Y 6 2 f Pcr r 4 l4 i ILr ,Current Property owner(s) M t' 1 Ran c ti f.t r Day phone 3 Z Mailing address 146 2/ Pcirtc 1t111.r D. ice¢ Ac!,: A- k- 9,?,!; -1,!r Real Estate Agent (� r S M r ch a e e) P eLt offn ii4 Day phone 76 Z - 58 3 2 . 230 - sr7 7 2.' TYPE OF DWELLING: Pl pcv[ cal it or 2 —.n ca, l Rea /fir ® Single Family (wltivo ADO) bJ m Lo Gr l et r• kc+ , n of whin El Duplex ❑ Multiple Dwellings (Single Family and/or Duplex) Cis p 3. NUMBER OF BEDROOMS: 3 4, TYPE OF WATER SUPPLY: TYPE OF WASTEWATER DISPOSAL: Individual Well ® Individual Individual Water Storage ❑ Holding Tank ❑ Community Class Well ❑ Community ❑ Public Water System ❑ Public Sewer ❑ Received by: aA, All f (,I(v W Date: l' COSA to be released to the engineer, unless otherwise requested by the engineer. COSH Fee $ `t q ` Waiver Fee $ Date of Payment l `/3 Date of Payment Receipt NumberQf`j �JrS� Receipt Number COSA# ez3//s7/Waiver S. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, ~zbased :on procedures outiided in the. Certificate of On -Site Systems Approval Guidelines for. this application; shows that the on-site water supply and/or wastewater disposal system Is (are) safe, functional. and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information Obtained from the Municipality of Anchorage flies and from my investigation and inspection, the onsfte water supply and/or wastewater disposal system ls(aro) in compliance with all applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation. Name of Fro 1= fcd �&w Tc cG, n i ca/ S e rvr� v Phone . 3 Ns- I � ss Address- /119 -:rep Cr -4o 4e?,iA ., A- C6 Engineer's Printed Name /f r rc a Date .. .. A `.. (:. s DSD SIGNATURE ERIN, System 01 Approved for bedrooms. �fc2 17 ham, System #2 Approved for bedrooms. q E 1K y Disapproved. Conditional approval for bedrooms, with the following stipulations Uk an, 16'_ By: l—' Original Certiffcate.Date:— The' unid li o Anchorage Development Services Division (DSD) issues Certificates of On -Site Systems Approval (COSA) based only upon the representations given in paragraph 5 by an independent professional dvii engineer registered in the State of Alaska. The Municipality of Anchorage Is not responsible for errors or omissions In the professional eng'ineer's work. 7. ATTACHMENTS: COSA Checklist X Septic System Advisory Well Flow Advisory Nitrate Advisory Arsenic Advisory Other r=: B. SEPTIC/HOLDING TANK DATA Tank Type/Material _ %(yri et n f -e x / S %r e l Date installed 17- m0 Tank size "t . gal. Number of Compartments 2. Cleanouts (Y/N) Y Foundation cleanout (YIN) Y Depression over tank (Y/N) . N High water alarm (Y/N) Y Date of pumping 1nrp 6//►/t2 Pumper A{- /FKeha��. qnk C. ABSORPTION FIELD DATA Date installed I a/S/ G7 Soil rating (g.p.d./ft2 or fe bdrm)3� System type 4" urda '�j• i Length 340' ft. Width ft: Gravel below pipe 0.7 it Total depth 3. Y ft. Eff. absorption area ► O fe .Monitoring tube Y Depression over field m Date of adequacy test H /&/ 20,13 Results (Pass/Fail) Pods✓ For _ bedrooms fluid depth in absorption field before test O in. Water added -7 _-27 gal. New depth__S in. Elapsed Time: _SQ_ min. Final fluid depth _ 0 in. Absorption rate >= '/s G g.p.d. Any rejuvenation treatment (past 12 mo.) (Y/N R type) IJ If yes, give date N • A If more than 1 septic system is on the lot: COSA CheGdist # . of Structure served by this system Certificate of On -Site Systems Approval Checklist Legal Description: _Lo f l-, 0 /ac k 2 Pee e, 4 #) I If #/ Parcel ID: O 17. — J y 2— I y A. WELL DATA Well type P If A. B, or C provide PWSID # — Well Log (Y/N) Y Date completed 3127 Ag Sanitary seal (Y/N) Y Wires property protected (Y/N) `f . Total depth J ► 7 ft. Casedao l�fL. Casing height (above ground) 33 in. FROM WELL LOG AT INSPECTION Date of test 3 / 2 > / 83 y / 8 / 20 r_3 Static water level 57 fl 15-3 ft Well production `/ 9 -P.M. 1.,� WATER SAMPLE RESULTS: Coliform :., O oolonlesll00 mL Nitrate 4 0. ! mg/L Arsenic 4 6- .ug/L Date of sample: Y W I.2-6 3 Colleded by f= let iii` AcY7 Tech -C-e r=: B. SEPTIC/HOLDING TANK DATA Tank Type/Material _ %(yri et n f -e x / S %r e l Date installed 17- m0 Tank size "t . gal. Number of Compartments 2. Cleanouts (Y/N) Y Foundation cleanout (YIN) Y Depression over tank (Y/N) . N High water alarm (Y/N) Y Date of pumping 1nrp 6//►/t2 Pumper A{- /FKeha��. qnk C. ABSORPTION FIELD DATA Date installed I a/S/ G7 Soil rating (g.p.d./ft2 or fe bdrm)3� System type 4" urda '�j• i Length 340' ft. Width ft: Gravel below pipe 0.7 it Total depth 3. Y ft. Eff. absorption area ► O fe .Monitoring tube Y Depression over field m Date of adequacy test H /&/ 20,13 Results (Pass/Fail) Pods✓ For _ bedrooms fluid depth in absorption field before test O in. Water added -7 _-27 gal. New depth__S in. Elapsed Time: _SQ_ min. Final fluid depth _ 0 in. Absorption rate >= '/s G g.p.d. Any rejuvenation treatment (past 12 mo.) (Y/N R type) IJ If yes, give date N • A D. LIFT STATION M. A. Date installed "Pump ore level at in. Datum Size in gallons 4AantiolelAcoess (Y/i q -__ _ 'Pump ofr level at in. High water alarm level at in. Cycles tested Meets alarm &circuit requirements? E. SEPARATION DISTANCES WELL ON LOT TO: Septic tankllift station on lot 105" On adjacent lots > Absorption field on lot ! 16 On adjacent lots > 14V41=1 Public sewer main N. A. Public sewer manhole/cleanout N• A, Sewer /septic service line > 2-S" Holding tank N • A, ;Animal Containment areas Manure/animal excrete storage areas A��a�> t ` SEPTICIHOLDING TANK ON LOT TO: Building: foundation 16" ''Property line —e 0,p Absorption field !o't Water main N. A. Water service tine 10 '. Surface water 6 S Wells on adjacent lots> to0 ABSORPTIONFIELD.ONLOT TO: - Property line SS Building foundation 20 Water main IV • A, Water Service line 1O ' Surface water 60 r ' Ddveway, paridngivehide storage > 30 ' Curtain drain No Ae Sean_ Wells on adjacent lots> F. COMMENTS SK/ �Gae` G(/4M SWoteahon a 4.fk4nler -at O7Oa6� ISSu�o� fl/26/2G07 G. ENGINEER'S CERTIFICATION I Certify that i have determined through field inspections and review of Municipal records that the above systems are in conformance with MOA COSA guidelines in effect on this date. Engineer's Printed Name E. Mae - Date 'i/ / 245�' / 2.0 1 2 COSA brown sheeL10-10-12.doc THECVORE F. AK?Oke .° CyE = 3589 ° t�AeK.®.ApAo aaAAa ` \, asnAaT nXwr euaa scsva \ o` AfM ..a. ecnrs , A61 \ WELL 2 ` EXISTING P HOUSE \ 3 ----------- M 0 M 904F9EQCIGSVS w -------------- N —' 25' MAIN. & DRNG ESMT $ _ N O 1$0.92' S890 53'50"E Z _ M &QNIf°�'26E 962• UNDER NO CIRCUMSTANCES SHOULD AN AS -BUILT BE USED FOR CONSTRUCTION OR FOR ESTABLISHING BOUNDARY OR FENCE ONES. THE SURVEYOR TAKES RESPONSIBWTY FOR THE INITIAL TRANSACTION ONLY AND ASSUMES FINANCIAL UABILITY ONLY FOR THE COST OF THE SURVEY. LISTED DISTANCES PREVAIL OVER SCALING. REPRODUCTION MAY CAUSE ERRORS IN SCALE. LOT SMEY SURVEY TYPE SYMBOLS FOUNDATION AS -&Air • SET REBARDRAINAGE ASPHALT ❑ FAIAL STRUCTURE AS -BUILT o FOUND REBAR 'a::..: CONCRETE ❑ PLOT PUN ... o CORNERS SET n T ... LOT s MER ... TON AS- UL 9--9 a WOOD FENCE E3 ASSUMED ELEV. -K--ii—* METAL FENCE ® WOW DECK PLOT PLANS & LOT SURVEYS NOTE: IT IS THE RESPONSIBILITY OF THE BUILDER OR OWNER, PRIOR TO ONLY THOSE IMPROVEMENTS ABOVE GROUND AND VISIBLEWILL BE CONSTRUCTION, TO VERIFY PROPOSED BUILDING GRADE RELATIVE SHOWN. FENCES, WELLS, SEPTIC CLEANOUTS. SIDEWALKS, DRIVEWAYS, TO FINISHED GRADE AND UTILITY CONNECTIONS AND TO OETERMINE ETC.. ARE SHOWN IN THEIR APPROXIMATE LOCATION, ONLY. SNOW THE EXISTENCE OF ANY EASEMENTS. COVENANTS OR RESTRICTIONS MAY PREVENT SOME IMPROVEMENTS FROM BEING SEEN AND LOCATED. WHICH DO NOT APPEAR ON THE RECORDED SUBDIVISION PLAT. ALL DISTANCES ARE RECORD UNLESS OTHERWISE NOTED. SURVEY CERTIFICATION s "R� Prepared by Robert E. Johns, Jr. & Assoc. PLOT PLAIT Ines, x111 A`Wel+..-Npw,...,r Ir enw rr r'r Irq a.1 uM I .•�-'""' �j Professional Land Surveyors Ave Iun/ r rWrr r M M Y alar• -`.•+*E %m. �' ♦ 1700 Brink Drive. ANCHORAGE, ALASKA 99504 r.r r ranita. na.a OIr �w �' Lot S.F. Ree. Plat Flle No. w � • -- �, 1 - � 1" = 50' FOUNDATION AS-BUA.T �•••• •• '� •• • ''' Date Surveyed: 04/21/13 Draws by RE J Checked b� MK Aarl L AraA+. aa+r +Ih rn Ave yrlrarl r, AriA1 ..» ArtleYl w tlr A% N we A eve • •••••• •••• ••• •••�••• ewirn N Ylrwallr � erw Ira.'• - r Q E. S. JR. ' I' p ;+✓ o Date Orara: 04/22/13 0"d: 3037 W.0 13-139 FINAL STRUCTURE AS -BUILT �i ; f. �: ,a�'� �. A'^ •-, Legal Description: L Aryl c AVM r. Arry ami, ur I �r"�.. w' aw"'°rin.e• uv« «• �,.� yea♦1 If eo p 4y• a Lot 1 BLOCK 2 e.rera r wa.alalr s cave nine., `ac ♦a � iota ion d ion PARK HILLS #1 Nunn ■ ■N■ on n■ ■ lWEER ■ r ■rrN r •�: r iri rrrsonB0 Boom man rr robin ■ i FAA.avanTeic® Fhdd Malnteeawn Beport Annual Inspection 4nahorageTank &Welding, Inc. 907-272-3543 Michael Rant h tti Reba= Copeland Mike unnearea. Mike Blakeslee 14621 Park Hills drive Angio" rage AK 99516 LN ise o e (9D7) 345,7852 Feeley lee roes RN Ma.e AX -115057 a.. er u t m.wLiu &5 SW070313 211073 RT 111916 06/78/2071 Retrieve O&M Info Daly naw Redno Nada Tlmar ealtlrr( , Perform Fkdd Sampling/06servi lens oaar m 7Yp� Musty ourthy ❑tlmdy Nan-byplael ❑SuMWe ❑Cabbage ❑DOI ally fmn In Pvu ❑ Vee No Feta In tw* ❑ Yea Nc Chock Central Panel R01M AWW Dladrerge A npa !�)l J, Audible and Wmal alArrns oK nisi eons (telemetry only) []NO Inapeat/dean Pump Sysiem Rlaar/Lld f Y� e ✓ oaar m 7Yp� Musty ourthy ❑tlmdy Nan-byplael ❑SuMWe ❑Cabbage ❑DOI ally fmn In Pvu ❑ Vee No Feta In tw* ❑ Yea Nc Chock Central Panel R01M AWW Dladrerge A npa !�)l J, Audible and Wmal alArrns oK nisi eons (telemetry only) []NO Inapeat/dean Pump Sysiem Rlaar/Lld Inspect ..................... Spice Box .................... Float Cods ...................J FbWs........................ Pump ........................ Bkdubea Firer ................. %Xuba Pump vault ............ Redmulagng Speller %tabs....... Comments Measure Sludge/scam Conrpadmem Baan Prerlous Cunem Prevfoua 2nd ComparonartICurnprK ..Previarc Curram InaPaet/Grran Advan%x Piker Oder, c Normal ❑ P' n.nt eforna4 RN'o�m�al ❑Emasom CX Bridahw%ndlna: K.yrrMG&I. ❑Excessin l"SPeaNfYean Discharge Pump System Inspect Rlesrh.ld ❑ solice Box ❑ Flcae awds ❑ MAINZ t ehlon rwaft ❑ ❑ Pump ❑ ❑ Inspect/Service ower System Camponente Inspect Clean Inspect Clean D110nfaa6an rMulpmant ❑ ❑ Dlspersai LBterelai'Otiaaes ❑ 0 Addluanaisarviess Rendered ❑ Cleaned WXft cheate7 ❑ Replaced W neme7 ❑ ReplacedAJaed od. Rema? Paha Used: W = Warrm* a . BlBable (✓ appropriate selseftn) W B INet Number DeeeWeea. FinaU8a/agr lnspentlon /✓f Xm retrlstaied oasaI reconnected; Rush wives ak.5d Sumr�n'IMrOdcommsndstions ' Syelsm Performing; no furtlrer sedan heodea l❑ Call rho service Fax completed form to 1-8$6-584�7404 RrYI 4,r td i U,- MWc boNed on /y WoMml panel ncaatNatad ❑Tank needs pumpinp ❑ othet? i r MAINZ t ehlon rwaft ❑ ❑ Pump ❑ ❑ Inspect/Service ower System Camponente Inspect Clean Inspect Clean D110nfaa6an rMulpmant ❑ ❑ Dlspersai LBterelai'Otiaaes ❑ 0 Addluanaisarviess Rendered ❑ Cleaned WXft cheate7 ❑ Replaced W neme7 ❑ ReplacedAJaed od. Rema? Paha Used: W = Warrm* a . BlBable (✓ appropriate selseftn) W B INet Number DeeeWeea. FinaU8a/agr lnspentlon /✓f Xm retrlstaied oasaI reconnected; Rush wives ak.5d Sumr�n'IMrOdcommsndstions ' Syelsm Performing; no furtlrer sedan heodea l❑ Call rho service Fax completed form to 1-8$6-584�7404 RrYI 4,r td i U,- MWc boNed on /y WoMml panel ncaatNatad ❑Tank needs pumpinp ❑ othet? ADVANCED WASTEWATER TREATMENT SYSTEM MAINTENANCE AND REPAIR AGREEMENT MEMORANDUM OF UNDERSTANDING BETWEEN MUNICIPAJJTY OF CHORAGE AND4LK & tikvF�.G� Piv r,dnn� THIS MEMORANDUM OF UNDERSTANDING made and entered into as of this Ai Day of Mq�r of 20.3 by and between AAL6d1 d' Wf 11 r herein the "OWNER," and the Municipality of Anchorage, herein the "MUNICIPALITY." In consideration of the mutual covenants contained herein, the parties to this Memorandum of Understanding agree as follows: 1. ADVANCED WASTEWATER TREATMENT SYSTEMS. Municipality grants permission to Owner to utilize and operate an Advanced Wastewater Treatment System (AWWTS), described as �/ fp X located at Nod(, a- I pa', -u4; SlS �, Anchorage, Alaska. 2. Definitions. A. Alteration. Any change to the design or function of an AW WTS that Includes the installation or removal of any parts, components or pieces not included in the original construction permit and design. Prior to performing any alterations to an AW WTS the owner must obtain a Wastewater Disposal System Construction Permit from the Municipality pursuant to Anchorage Municipal Code (hereinafter, "AMC') 15.65. B. Certificate of On -Site Systems Approval. An approval by the Municipality of existing water and wastewater disposal systems given at the time of property sale and title transfer in accordance with AMC 15.65. These approvals certify that the systems are adequate for the homes that they support and meet the codes that were in place at the time of system construction. C. Damage. Any man-made or natural change in a system that would inhibit the system from performing as designed. D. Maintenance and Repair. The scheduled and as needed replacement of existing parts, components and pieces of an AW WTS that were included in the original design which would allow the AWWTS to continue to perform as designed. E. Permit (Construction) An On -Site Wastewater Disposal System Construction Permit as defined by AMC 15.65. F. Permit (Operating) An Advanced Wastewater Treatment System Operating Permit. An annual permit, issued by the Municipality, that allows the Owner to operate an AW WTS, upon meeting all the requirements of this agreement, the conditions of Operating Permit, the requirements of the On -Site Wastewater System Construction Permit and all relevant provisions of AMC 1.5.65 / 3. Fee. Owner shall pay to Municipality an annual fee of 1/ ($ � .00), payable on or before the issuance of the operating permit and annually thereafter. The annual fee is due on or before the anniversary date of the approval by the Municipality of installed system. 4. Term. The term of this Memorandum of Understanding shall be for the life of the FAIL, I= The term begins on the date of approval by the Municipality of the installed system and shall continue while the AWWTS system is in use or operational or until the property is sold or title is transferred by owner and a new certificate of On -Site approval is issued to the new owner or transferee of the property. 5. Alterations. Installation and Removal of Additional Equipment. Owner agrees not to make any alterations, removal of parts or additions to the AWWTS without a Construction Permit from the Municipality. 6. Maintenance and Repairs A. Throughout the term of this Memorandum of Understanding, the Owner shall maintain AWWTS in good repair. In addition, it shall be the responsibility of the Owner during the term of this Memorandum of Understanding, and any extensions or renewals thereof, at the owner's sole expense, to pay for any and all: (1) repair(s), (2) maintenance, (3) adjustment(s), (4) replacement costs, and (5) inspection costs. Further, Owner agrees to comply will all applicable ordinance, laws, regulations, rules and orders for the AWWTS. B. Owner agrees to provide the Municipality a written schedule of routine maintenance and repairs which have been performed on the system pursuant to the terms and conditions contained in the Owner's AWWTS Operating Permit. This schedule shall be submitted to the Municipality annually upon the renewal of the permit. The schedule of maintenance and repair contained in the Owner's AWWTS Operating Permit is: C. Owner acknowledges that the fine schedule for failing to maintain and repair an AWWTS are codified in AMC 14.60. D. Owner agrees that only maintenance, repair personnel certified by the Municipality will inspect and make any necessary maintenance, repairs or permitted alterations to the system. E. Owner agrees to grant the Municipality reasonable access to test and inspect the AWWTS upon 24 hours written notice. F. Owner agrees that any sale or transfer of title of the property will not occur without a new Certificate of On -Site Systems Approval. G. Owner agrees that the relevant provisions of the standard specification guidebook for AWWTS is the governing professional guidelines for the construction, maintenance and repair of the Owner's AWWTS. 7. Nonwaiver. The failure of either party at any time to enforce a provision of this Memorandum of Understanding shall in no way constitute a waiver of the provisions, nor in any way effect the validity of the Memorandum of Understanding or any part hereof, or the right of such party thereafter to enforce each and every provision hereof. 8. Amendment. A. This Memorandum of Understanding shall only be amended, modified or changed by a writing, executed by authorized representatives of the parties, with the same formality of this Memorandum of Understanding was executed and such writing shall be attached to this Memorandum of Understanding as an amendment. B. For the purposes of any amendment modification or change to the terms and conditions of this contract, the only authorized representatives of the parties are: Owner: Anchorage: Purchasing Officer H C. Any attempt to amend, modify, or change this contract by either an unauthorized representative or unauthorized means shall be void. 9. Jurisdiction: Choice of Law. Any civil action arising from this Memorandum of Understanding shall be brought in the Superior Court for the Third Judicial District of the State of Alaska at Anchorage. The laws of the State of Alaska shall govern the rights and obligations of the parties under this Memorandum of Understanding. 10. Severability. Any provisions of this Memorandum of Understanding decreed invalid by a court of competent jurisdiction shall not invalidate the remaining provisions of the Memorandum of Understanding. O Date: STATE OF ALASKA THIRD JUDICIAL DISTRICT MUNICIPALITY: By: Title: Date: ) ss. The forego'instrument was acknowledged before me this 2 day of 20 , by f C fr ®ate r *F 5?14 5,q v ,IC POR ALASKA expires: 6112$ • / q MUNICIPALITY OF ANCHORAGE Department of Health & Human Services DIVISION OF ENVIRONMENTAL SERVICES 343-4744 Parcel I.D. # CERTIFICATE OF INSPECTION FOR HEALTH AUTHORITY APPROVAL OF ON-SITE SEWER AND WATER FACILITY FOR SINGLE FAMILY DWELLING 1. GENERAL INFORMATION (Must be completed prior to submittal) (a) Legal Description (include lot, block, subdivision, section, township, range) Location (address or directions) / Fo" 8/ (b) Property owner C/~'rf &-~7'~t,n Telephone: (home)3'f'5'"~'Y¢~¢' Business Mailing Address (c) Lending Institution Mailing Address Telephone (d) Real Estate Company and Agent Address :~30~ '~J" Z'f..~ Telephone 5""O"~- 7'd',~'_? (e) Mail the HAA to the following address: (or check here F~, if hold for pick up.) List contact person and day phone number below: 2. TYPE OF RESIDENCE Single-Family [] Number of bedrooms 3. WATER SUPPLY Individual Well [] Community [] Public [] Note: If community well system, must have written confirmation from the State Department of Environmental Conservation attesting to th legality and status. 4. SEWAGE DISPOSAL On-site [] Public [] Community [] Holding Tank [] Note: If community well system, must have written confirmation from the State Department of Environmental Conservation attesting to the legality and status. 72-025 (Rev. 7/88) Page 1 of 2 5. ENGINEERING FIRM PROVIDING INSPECTIONS, TESTS, FILE SEARCH, DATA AND INFORMATION As certified by my seal affixed hereto and as of the validation date showr~ below, I verify that my investigation of [his Health Authority Approval shows that the on-site water supply and/or wastewater disposal system is safe, functional .and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is in compliance with all Municipal and State codes, ordinances, and regulations in effect on the date of this inspection. Na.me of Firm F('~'/--~¢,/~ ~"¢c4,~¢crj' ~'e~,~ Telephone Address Date 6. DHHS APPROVAL Approved for ~ bedrooms by Approved ,,~ Disapproved Terms of Conditional Approval Conditional Date_ The Municipality of Anchorage Department of Health and Human Services (DHHS) issues Health Authority Approval cerificated based only upon the representations given in paragraph 5 above by an independent professional engineer registered in the State of Alaska. The DHHS does this as a courtesy to purchasers of homes and their lending institutions in order to satisfy certain federal and state requirements. Employees of DHHS do not conduct inspections or analyze data before a certificate is issued. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. 72-025 (Rev. 7/88) Back Page 2 of 2 Tom Fink, Mayor unicipality of Anchorage Department of Health and Human Services 825 "L" Street P.O. Box 196650 Anchorage, Alaska 99519-6650 343-4744 April 10, 1989 Ted Moore, P.E. Flattop Technical Services 14530 Echo Street Anchorage, Alaska 99516 Subject: Waiver Request for Lot 1 Block 2 Park Hills S/D Waiver Request ~WR890012, HA890123, PID ~017-142-14 Dear Mr. Moore: Your request for waiver of the required 10 foot separation between a septic system and a lot line has been approved. waived distance is 2 feet. The This approval applies to the existing septic system lot line separation only. Any future upgrade to the septic system will require all separations be met or another approval from this department. Sincerely, Daniel J. Roth Civil Engineer On-site Services DJR/ljw~7 MUNICIPALITY OF ANCHORAGE (MOA) Health Authority Approval (HAA) CHECKLIST - FEBRUARY 1984 343-4744 Legal Description: Well Classification Well Log Present (Y/N) 'r' Date Completed 3 / 8 ? ¢'~'.~ Total Depth 11'7' Cased to It"t ~ Depth of Grouting N,/J,. If A, B, C. D.E.C. Approved (Y/N) Yield Static Water Level ~-0 ' Casing Height Above Ground ~'" Electrical Wiring in Conduit (Y/N) SEPARATION DISTANCES FROM WELL: To Septic/Holding Tank on Lot t 0 To Nearest Edge of Absorption Field on LOt To Nearest Public Sewer Line To Nearest Sewer Service Line on Lot Water Sample Collected by 7 Water Sample Test Results Comments Pump Set At It ~ / Sanitary Seal on Casing (Y/N) Depression Around Wellhead (Y/N) N ; On Adjoining Lots i a~,' ; On Adjoining Lots To Nearest Public Sewer Cleanout/Manhole ; Date B. SEPTIC/HOLDING TANK DATA Datelnstalled.~'/I-~/~9--v Size IO00~,otl No. of Compartments ~- Standpipes (Y/N) ~ Air-tight Caps (Y/N) Depression over Tank (Y/N) N Pumping/Maintenance Contact on File (Y/N) N,At. Holding Tank High-Water Alarm (Y/N) l~l./'t. SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK: To Water-Supply Well 149 ~ ~ To Building Foundation To Property Line ~"O ~ To Disposal Field To Water Main/Service Line ~ ~5'~ T' Foundation Cleanout (Y/N) Date Last Pumped lO/Ef//',~' ; for Temporary Holding Tank Permit (Y/N) tO' To Stream, Pond, Lake or Major Drainage Course 7'~ P~rt~ /.JttO' .C~b,:~/,u,..~,,,~ ,/~'~ ~/~/~ Comments ~ cree~ ~emenf ~(o~ ~ ~o~ /o/ /,~ ~wm ~Ae~ ~o ~e/ ~ Page 1 of 2 ~ . C. ABSORPTION FIELD DATA Soils Rating in Absorption Strata Date Installed ~-~"/I-~ /~'-~ Width of Field ,~ J Square Feet of Absortion Area Depression over Field (Y/N) hi Results of Last Adequacy Test ~'/g~r~t-1 Type of System Design "'/-'r-¢,~¢~ Length of Field Depth of Field Gravel Bed Thickness Standpipes Present (Y/N) Date of Last Adequacy Test SEPARATION DISTANCE FROM ABSORPTION FIELD: To Water-Supply Well 1¢8' To Property Lin~ To Building Foundation ~ j' To Existing or Abandoned System on Lot ~0,4-. ; On Adjoining Lots To Water Main/Service Line .~ ~',5"' To Cutback (if present) -~',~'~ To Stream, Pond, Lake, or Major Drainage Course To Driveway, Parking Area, or Vehicle Storage Area Comments ~.. /~ ~¢~,-~ ~.~/?'~¢..5' . ,/~.~. ~,~'/~,//' D. LIFT STATION Date Installed Size in Gallons "Pump On" Level at High Water Alarm Level at Tested for Meets MOA Electrical Codes (Y/N) Comments Dimensions Manhole/Access (Y/N) "Pump Off" Level at Vent (Y/N) Pumping Cycles during Adequacy Test. **Check Permitted Bedroom Rating Against HAA Request** I certify that I have checked, verified, or conformed to a MOA and HAA gAd~ j.b'~!~):~.ffect on the date of t' s inspection. ~/~"~;, ¢'; ...........................d En ineer'sSeal Date /¢¢/¢?,/ .~ /)~¢.,) ~.~'/".~,~,,~,-,, ~' 2..-¢'Z¢-~ [J g ' MOA No. ~¢ ,- ~::2.~'~. ¢, , ,, Receipt No. ~__ __/~'. ~ Receipt No. Date of Payment ¢'~ ,-,~ ~' ~d~/~' Waiver Fee: $ Amount: $ /2ff~9 ~ ~) Date of Payment LI~ 72-026 (Rev. 7/88) Back Page 2 of 2 ! NOTES: I. I! ~IHAL, L. Im THIr REIPONSJ~II.I?y OF THE: IUil. OrR OR IUILDINt LOP.,ATI~N IHO~IN M[ITI Al.l, IU~DPII~ION COYe'NANtl AND ZONINO ~..I¥ Ii THE ~I'IPONIIIIII. ITy OF' THE IUII, DJR TOV[RIFY AI,.c IH. Ir¥&?iONI V ........... JIIIPIAY fO Akl. -I,~lhl..T.I III I I, IT 8Hlh[ BE THE REIPONSII~ITY OF THE IUI~DIR OROWNER ~YERIFY. IUI~DIN~ ~T~ I~ MEET8 A~ S~D~WlON COVENANTS AND ~lNG .: ~ ]. THI= pLAT.REP~[~ THE PANEL OF PROP~TY DESCRIBED BZL~ TAKEN ' ,R[CORDED PRIOR ~ O~AFTER THE FI~INIOF THE A[OOROEO.PgAT."-: 4. THE INF~T~ ON ~IS ~AT IS FOR TH[ US~ OF L[NDING WSTIT~IONS . ~ECIFICALLY TO 8~W~ CONFkI~$:BET~EN .EX~TINO ~R~TUR[$ A~ P~D ~T LINE~ ~ EAIEMEN~, THE ~AT I~ NOT ~ BE U~ED FOR P~ITIONIH~ . , . : ~-['1o~,1' NO,; t: ::. 349.6537 6937 Old Semord Hiohwav APpL|: NT FILLS OUT UPPER HA! ONLY Property, Ot;me~ _~' 7]~_ \[ :4~ /L'b / (~/~,~/' "-.~-. Phone Address (.L ~;) /_ /.) C ~ ~_ / (] .4_.., /./<.. ~ ~. (_ /-~ ~.j ? /¢' ./I ~ Zip Code Lending Institution Address .~ -.. z./~/ ~ ~,: A ? ~/t:~ ((. ./~' /,'~ ('{~ /~ A: Zip Code Realty Co. & Agent Address / .~ Legal Description Street Locati~ Type of Residence [~Single Family [] Multiple Family [] Other Phone Phone No. of Bedrooms Water Supply []~( Individual Community [] Public Utility ATTACH WELL LOG. A well Icg is required for all wells drilled since June 1975. For wells drilled prior to that date, give well depth (attach Icg if available). Sewer Disposal /~ Individual Public Utility [] Holding Tank Year Individual Installed: When Connected to Public Utility: NOTE: THE INSPECTION FEE MUST ACCOMPANY EACH REQUEST BEFORE PROCESSING CAN BE INITIATED. Time Time Time Time Date Date Date Date Inspector Inspector Inspector Inspector ~ E.. C- ~ MUNICIPALITY OF ( C~ ~~ --_~__ _ __ ENVIRONMENTAL (~ ) APPROVED BEDROOMS 'CONDITIONS OF APPROVAL~ ~ ~ ) ~SA.PROWP ) CONDITIONAL APPROVAL* Soils Rating Date ~wer Installed Well To Absorption Area I (~) '~ Well Log Received ,~:~ % Well to Tank / ~ C) Septic T~k Size