ON-SITE WASTEWATER INSPECTION REPORT
Permit Number: SW080018 PID Number: 018-273-02 ❑ New ❑✓ Upgrade
Name:
Thomas & Terese Moll
ABSORPTION FIELD
❑ Deep Trench El Shallow Trench ✓❑ Bed ❑Mound
Address
4900 Rabbit Creek Road Anchorage, AK 99516
❑ Other
Phone
Number of Bedrooms
Soil Rating
Total depth from original grade
4
•8 GPD/SF
3.6 Ft.
LEGAL DESCRIPTION
Depth to pipe invert from original grade
2.1 Ft.
Gravel depth beneath pipe
1.5 Ft.
Subdivision Block Lot
Goldenview Park Phase Al 1 3
Fill added above original grade
7-8 Ft.
Gravel length
50 Ft.
Township Range Section
Gravel width
15Ft.
Beds: Number of Lines
3
Distance between lines
5Ft.
SEPARATION
DISTANCES
To
Septic
Absorption
Holding
Sewer
Total absorption area
Number of trenches
Dist. between trenches
From
Tank
Field
Lift Station
Tank
Line
750 2
Ft
Two
>
>1017t.
Well
>100'
>100'
N/A
N/A
>25'
TANK p Septic ❑ S.T.E.P. ❑ Holding ❑ Other
Manufacturer
Anchorage Tank
Capacity
1 1,250Gal.
Surface Water
>100'
>100'
N/A
N/A
Material
Number of compartments
Lot Line
>5'
>10'
N/A
N/A
Steel
Two
NA
Foundation
>5'
>10'
N/A
N/A
LIFT STATION
Manufacturer
Capacity
Curtain Drain
None
Noted
Gal.
RemarksExisting Septic Tank Decommissioned i n
Pump on level at
in.
Pump off level at
in.
High water alarm at
in.
Accordance with Municipal Code.
Pump make and model
Electrical Inspections performed by
Installer
PIPE MATERIAL House to tank D3034 drainfield Tank to
D3034
Guaranteed Services
Drainfield F810 CO/MT. D3034
Inspector A. Harala
BENCH MARK (Assumed elevation) 100.Oft
Inspection�s' 6/11/2008
dates: 2.a 6/12/2008
Location and description
3°' 5/14/2014 4`h
Garage Slab.
COMMUNITY DEVELOPMENT DEPARTMENT APPROVAL
1114
��
�•• •�'S'���♦
Conditional Approval: Date
AV G);
r
••
r�.. 49TH � .�♦
�.. 0000. ... ... .,....:....
0
/0060 ...........................
�� MICHAEL E. ANDERSON :
♦ J,: CE -4381 ..4�'r
AW
Fp '••0000•• •
Approved Date �� �/
1 RO FF`WOO �vo
�
inspection Kepon_1-1YIL.aoC
n ZOL
p O
s
a za
c
is
cr
NAV rn II
' N W02'39"E 306.42'
E
2Au�
rm I
/
mt— 9, u, a " j n / m S =4 tm7 I 50 00`
cn w rn cn w
i0
o
1 1 1 I
1 s
1 1 ►�'®� \n'rn —1. Y I erg
1L
gat rn
CD
rTl
F —
_1•'' \ +_ tea. \ 3.*Z.*0.00 S
g1
,*9 -LL 3.*?.tr0A4 S I
4 —�
4
g tdIlia:}®l�ie A,
Or -
06 '�
----------r�,---- --- I
t-1 � z o cy
I—zr'� .®
C) (A
c�
O
P.a
Permit Number: SW080018
Municipality of Anchorage Page 3 of 3
DEVEOPMENT SERVICES DEPARTMENT
4700 South Bragaw Street Anchorage, AK. 99519-6655 - 343-7904
on c
Finished Grade
Existinq Ground
74.1 --,"
1
N
H
lS
83.6
76.2
—Drainfield Rock
72.6
Groundwater @ 67.2
6-11-08
66.2
15'
PROFILE AS -BUILT -
Scale: V= 10'
PID No. 018-273-02
.•W OF
��e
•••�P�E .....q �•..,
AV
A- :
v 49th
'::...
c..z?. ,:� :� .
0 �'; MICHAEL E. ANDERSON
•� No. CE -4381
♦� �.pR�FESSi�NPi••v
DATE
MUNICIPALITY OF ANCHORAGE
GROSS TIME
.��&VaILmUVA1,'
DEPTH To
WATER
DEVELOPMENT SERVICES DEPARTMENT
���P1 •.., •♦0��
4700 BRAGAW STREET ANCHORAGE, AK 99519-6650'
2:13
2.25"
49th ....:.........SOILS
2:43
LOG -PERCOLATION TEST;�RZA
10.13"
7.88"
3
2:44
- 1. MICHAEL E. ANDERSON ;' j
2.50"
LEGAL DESCRIPTION: GOLDENVIEW PARK PHASE Al, BLOCK I, LOT 3
,#� NO. CE -4381
3:14
PERFORMED FOR: THOMAS MOLL
10.25"
ei p ... •�
♦4141,e11
DATE: 6-4-08 PROJECT No.:
3:15
RESS �•
2.00"
PARCEL ID#: TECHNICIAN: A. HARALA
Professional En ineersStamp:
DEPTH
TEST HOLE 2
"
(feet)
1flTrM
OB/OG SLOPE
SITE PLAN
2
3
4
5
GW/GM
6
7
8
9
10
BOH WAS GROUND WATER ENCOUNTERED? No
IF YES a WHAT DEPTH? S
DEPTH OF WATER AFTER MONITORING: 9 O
11
DATE OF MONITORING: 6-11-08
12
13
(MINUTES)
(MINUTES) (INCHES) (INCHES)
14
TEST
HOLE PRESOAKED PRIOR TO TESTING:
15
16
17
18
19
6
3:45
30 9.75 7.75"
20
PERCOLATION RATE: 3.9 (MIN/INCH)
PERC. HOLE DIA. 6 (INCHES)
TEST RUN BETWEEN: 2
FT. and 3
FT.
COMMENTS: TEST HOLE PRE SOAKED PRIOR TO TEST.
TEST PERFORMED BY ANDERSON ENGINEERING. 1, MICHAEL E. ANDERSON CERTIFY THAT
THIS WAS PERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPLE
GUIDELINES
IN EFFECT ON THIS
DATE: 6-11-2008
DATE
READING
GROSS TIME
NET TIME
DEPTH To
WATER
NET DROP
1
2:13
2.25"
2
2:43
30
10.13"
7.88"
3
2:44
2.50"
4
3:14
30
10.25"
7.75"
5
3:15
2.00"
"
MUNICIPALITY OF ANCHORAGE
Development Services Department
Onsite Water & Wastewater Program
4700 South Bragaw Street
P.O. Box 196650, Anchorage, AK 99519-6650
(907) 343-7904
ON-SITE WASTEWATER DISPOSAL SYSTEM PERMIT
Upgrade
Date Issued: Mar 12, 2008
Expiration Date: Mar 12, 2009
Permit Number: SW080018 Parcel ID: 018-273-02
Legal Description: GOLDENVIEW PARK PHASE Al BLOCK 1 LOT 3
Design Engineer: 0014 ANDERSON ENGINEERING
Owner Name: THOMAS P. & TERESE R. MOLL
Owner Address: 4900 RABBIT CREEK ROAD
ANCHORAGE. AK 99516 -
Site Address: 4900 RABBIT CREEK ROAD
Lot Size: 114270 SO. FT.
Total Bedrooms: 4 Permit Bedrooms: 4
This permit is for the construction of:
n Disposal Field ❑✓ Septic Tank ❑ Holding Tank ❑ Privy ❑ Private Well ❑ Water Storage
All construction must be in accordance with:
1. The attached approved design.
2. All requirements specified in Anchorage Municipal Code Chapters 15.55 and 15.65 and the State of Alaska
Wastewater Disposal Regulations (18AAC72 ) and Drinking Water Regulations ( 18AAC80 ).
3, The engineer must notify DSD at least 2 hours prior to each inspection. Provide notification by calling
(907) 343-7904 ( 24 hours). ( Not required for a Water Supply Permit only).
4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather
must be either: A. Open and closed on the same day.
B. Covered, sealed, and heated to prevent freezing.
5. The following special provisions.
THE ENTIRE SUBSURFACE DISPOSAL FIELD IS NOT WITHIN A 30 FOOT RADIUS OF A PERCOLATION TEST.
THE ENGINEER NEEDS TO DO AN ADDITIONAL PERCOLATION TEST PRIOR TO THE CONSTRUCTION OF
THE SEPTIC FIELD. PLEASE SUBMIT STAMPED AND SIGNED RESULTS WITH THE AS -BUILT INSPECTION
REPORT. IF THE RESULTS REQUIRE A DESIGN CHANGE, CONSTRUCTION OF THE SYSTEM WILL STOP
PENDING ON-SITE REVIEW AND APPROVAL.
DECOMMISSION OLD CRIB AT TIME OF CONSTRUCTION IF NECESSARY.
Received By:
Date: 3—IL-61
Municipality of Anchorage
Development Services Department
Building Safety Division
On -Site Water and Wastewater Program
4700 Bragaw Street
P.O. Box 196650
Anchorage, Alaska 99519-6650
www.muni.org/onsite
(907)343-7904
ON-SITE SEWERIWELL PERMIT APPLICATION
FOR A SINGLE FAMILY DWELLING
Parcel I.D. 018-273-02
Property owner(s) Thomas P. & Teresa R. Moll Day phone 306-2442
Mailing address 4900 Rabbit Creek Road Anchorage, AK Zip Code 99516
Site address 4900 Rabbit Creek Road Anchorage, AK Zip Code 99516
Legal description (Sub'd., Block & Lot) Lot 3, Block 1, Goldenview ParkSubdivision, Phase Al
Legal description (Township, Range & Section)
Lot Size 114.270 Sq. Ft. Number of Bedrooms Four (4)
THIS APPLICATION IS FOR (® all that apply):
Absorption Field ID
Septic Tank El
Holding Tank
❑
Privy
❑
Private Well
❑
Water Storage
❑
THIS APPLICATION IS AN:
Initial
Upgrade
Renewal11
El
El
certify that the above information is correct. I further certify that this application is being made for a
Single Family Dwelling and is in accordance with applicable Municipal Codes.
M'r�jj E- �
(Signature of property owner or authorized agent)
Permit/RushFees: 1-/ 110
Date of Payment: Cqoj y /o0p
Receipt Number. �riY)
(Rev. 11105)
Waiver Fees:
Date of Payment:
Receipt Number.
ANDERSON ENGINEERING
P.O. BOX 240773
ANCHORAGE, AK 99524
MEMORANDUM
DATE: March 7, 2008
TO: Deb Wockenfuss
FROM: Mike Anderson, P.E.
SUBJECT: Lot 3, Block 1, Goldenview Park Subdivision Phase Al
Septic System Permit Upgrade Permit
We have reviewed your comments and made the following revisions:
1. An additional percolation test will be completed during construction of the
absorption bed with results submitted with the As -Built Inspection Report. If the
results require a redesign construction of the system will stop pending On Site
review and approval.
2. The reserve site will be the existing absorption bed with an extension to the
southwest to accommodate the four-bedroom system.
3. The old crib was abandoned in 1990. The location is shown on the Site Plan.
4. The subdivision to the south of this lot is served by City water and sewer. No
information is available on the lot to the west, but the new absorption bed is
more than 100' from any well on the lot. All other features within 200' of the new
system are shown on the Site Plan or Area Map which are both drawn to scale.
5. Cleanouts in the existing bed have been added to the Site Plan.
Please advise if additional information is required prior to issuance of the upgrade
permit.
ANDERSON ENGINEERING
P.O. BOX 240773
ANCHORAGE, AK 99524
522-7773 677-7766 (FAX)
February 25, 2008
Municipality of Anchorage
Development Services Department
On -Site Water and Wastewater Program
4700 South Bragaw Street
Anchorage, AK 99519-6650
Subject: Lot 3, Block 1, Goldenview Park Subdivision Phase Al
Septic System Design and Permit Application
Impacts to Adjacent Properties
Dear Onsite Services Engineer:
The existing absorption system on the subject lot has failed and must be upgraded prior
to issuance of a Certificate of On Site System Approval for the property. We are
therefore requesting a permit be issued for the upgrade of the septic system to
accommodate the four-bedroom home on the lot. The attached Site Plan and backup
documentation identify the location and configuration of the existing and proposed
septic system. The existing septic tank will be pumped, crushed and backfilled with
sand. The absorption system will be abandoned in place. Also identified on the plans
are the locations of the existing well and Rabbit Creek at the south property line. No
conflicts exist between the proposed septic system and the wells on this or adjacent
lots. Drainage arrows are shown indicating the current drainage patterns. The
drainage patterns will be maintained after construction.
The test hole was placed on the lot when the existing septic system was constructed in
1994. This test hole indicated gravel with cobbles and silt were found. The percolation
rate was determined to be 4.2 minutes per inch. Additional test holes will be placed
during construction to verify the soil conditions. A revised design will be submitted for
approval if conditions are different than those anticipated. We are proposing to
construct a 1,250 gallon septic tank and a 50' long by 15' wide absorption bed with .5'
of gravel beneath the distribution pipe. The distribution pipe in the bed will be placed at
2.5' below the surface with the total depth at 3'. Groundwater was noted at 9' below the
ground surface during placement of the initial test hole.
The ground surface on the lot slopes slightly to the west in the area of the absorption
bed. The bed will be placed parallel to the contours of the ground as much as possible
Lot 3, Block 1, Goldenview Park Phase Al
February 25, 2008
Page Two
and in conformance with design criteria. A minimum of 100' will be maintained between
all components of the septic system and the proposed well and from any surface water
in the area.
If the system is constructed in accordance with our design the following statements
apply:
The system, if constructed as designed, will have no adverse impact on the wells
in the area or those to be constructed in the future.
2. The system, if constructed as designed, will have no adverse impact on existing
septic systems in the area or those to be constructed in the future.
3. The system, if constructed as designed, will have no adverse impact on reserve
space, either surface or subsurface, on any lots located in the area.
4. The system, if constructed as designed, will have no adverse impact on drainage
patterns in the area. The current drainage pattern will be maintained.
Sincerely,
w EA fit"
Michael E. Anderson, P.E.
Attachments
V C -A!'.. C e\XRSCv
RAWT CREEK ROAD
Lar 5A
BLDCK B
Ttweeam 110. 1
U E
�.n City\ Sewer��
City \Water
1 �
...............
.,
i 4..th /..1 .s....
.............. . .� AREA MAP
0.
;NIpUEL C ANDERSON = SCALE V = IOU'
1No. CE-4381
••••.............
SwMy11
��� 593 • ,•** 111
00
. iiiIs
1j ` •• N 00'02'39 3 .t2' I I
1111 „'•_ /
U
R-
13 3 [I \ \
N I N Ik
I 1
I m00
v
CD
\
W I
N N
/ 09'LS
3.1L,fo.00 S
a�b S
2
�9'tL 3.tL,10m S I
3A180 M31A39418e R.m
D � J I
R•
LOT 3, BLOCK 1, GOLDENVIEW PARK SUBDIVISION
PHASE Al
(LOT 1B, BLOCK B, TIMBERLUX SUBDIVISION NO. 1)
DESIGN FACTORS: SYSTEM REQUIREMENTS:
4 Bedroom Home Shallow Bed System
Perc. Rate: 1-5 Min./Inch 1,250 Gallon Septic Tank
Application Rate: .8 GPD/SF 1' Total Depth Drainfield Rock
4 Bedrooms X150 SF/Bedroom/.8 GPD/SF(Application Rate) = 750 SF Absorption Area
750 SF/15 LF (Width) = 50 LF Bed Length
THEREFORE: Construct A 50' Long x 15' Wide Shallow Bed as Shown Below.
Place Distribution Piping at 2.5' Below Original Ground Surface. Provide T of Cover
Over Bed and 4' of Cover Over Septic Tank. In Lieu of Fill Provide 2' of Insulation
and 2' of Fill. Place Diverter Valve to Insure Even Flow to Each Bed.
Existing Ground
2.0'
.5' O
.5'
Geotextile Fabric
O O
Drainfield Rock 4" PVC
Underlying GM
5' 5' 2.5'
TYPICAL BED SECTION ....�•OF•��.���
(NO SCALE) oe,,` ........................C.is,
�'J: • ``r��
NOTE: Grade Area Surrounding Bed to Drain Away.
Minimum 6' Separation From Bedrock..... ' 49th
Minimum 4' Separation From Groundwater.
7. f"...�4�...... ..._....'
Minimum 100' Separation From Wells in the Area. ♦"" n
♦ Michael E. Anderson µ
Minimum 100' Separation From Surface Water or Streams. . ♦��� : No. CE -4381 F'
Minimum 10' Separation From Water Service Line. sem'•,_
ON-SITE WASTEWATER DISPOSAL SYSTEM
CONSTRUCTION AND MATERIAL SPECIFICATIONS
SUBJECT: LOT 3, BLOCK 1, GOLDENVIEW PARK SUBDIVISION PHASE Al
GENERAL:
1. The scope of this project includes the procurement and placement of a new
1,250 -gallon septic tank at the location shown on the Site Plan. Work also
includes the construction of a new 50' long X 15' wide absorption bed at the
location also shown on the Site Plan. The distribution line in the bed will be
placed at 2.5' below the existing ground surface. Total depth of the bed will
be 3' below the existing ground surface. The new absorption bed and septic
tank must be placed a minimum of 100' from all private wells and any surface
water in the area and 10' from the water service line on the lot. A minimum of
3' of cover is required over the absorption trench and 4' of cover over the
septic tank. The existing septic tank must be pumped, crushed and
abandoned on site or removed from the property. The existing absorption
system will be abandoned in place.
2. Construction shall be in accordance with the approved site plan, design
drawings, Municipal Permit with any special provisions or conditions, and all
applicable State and Municipal Wastewater Disposal Regulations.
3. The Contractor shall be responsible for obtaining all underground utility
locates and for the layout of the septic system and verification of the location
of all lot lines. The Contractor must also verify the location of wells in the
area and assure that the separation distances are met.
4. Unless specifically agreed otherwise, the contractor shall be responsible for
final grading areas subsequently depressed from soil settling. Property
owner shall be responsible for revegetation of affected areas unless
specifically agreed otherwise.
5. Contractors installing wastewater disposal systems must be certified by the
Municipal Development Services Department Building Safety Division On Site
Water and Wastewater Program for system installations. Owners installing
their own systems must receive prior approval from the On Site Water and
Wastewater Program before beginning system installation.
SEPTIC TANK INSTALLATION
A new 1,250 -gallon septic tank must be procured from an approved source
and installed at the location shown.
Lot 3, Block 1, Goldenview Park Phase Al
February 25, 2008
Page 2 of 3
2. A septic tank is to be constructed by a certified septic tank manufacturer.
Construction shall include two 4" cleanouts for pumping access.
3. The septic tank shall be sufficiently bedded to prevent settling or shifting of
the tank.
4. All standpipes on the septic tank shall extend a minimum of 12 inches above
final grade.
5. Tanks installed without 4' of cover shall have a minimum of 2" of direct burial
insulation.
6. A foundation cleanout shall be installed one to four feet from the building
foundation. Two cleanouts are required between the tank and the drainfield.
7. Final grading over the tank shall be such that a positive slope exists away
from the septic tank.
DRAINFIELD CONSTRUCTION:
1. The drainfield shall be constructed to the dimensions shown on the design.
The bottom of the trench shall be within 2" of levet.
2. Distribution piping must be placed level with perforations down atop a level
bed of drainfield rock. Rock should then be placed over the pipe to provide a
minimum of 2" of cover.
3. A silt barrier or geotextile fabric must be placed between the drainfield rock
and the natural soil backfill.
4. Monitor tubes must be 4" in diameter and installed at the locations shown on
the design. The portion below ground must be perforated.
5. Contractor shall verify the septic tank and drainfield are a minimum 100' away
from any private water wells in the area, 150' from a Class "C" Well or 200'
from any community well.
6. Direct bury insulation must be placed over the distribution system if less than
3' of backfill depth is available. Finish grade over the trench must be
mounded to prevent settlement or depressions.
7. Grade area surrounding the absorption trench to drain away.
8. A minimum 2' of accepting soil is required below the drainfield rock for a 5'
wide trench. Contractor shall verify this condition prior to placement of the
rock. All pockets of unacceptable materials must be removed and replaced.
Lot 3, Block 1, Goldenview Park Phase Al
February 25, 2008
Page 3 of 3
MATERIAL SPECIFICATIONS:
Septic tanks must be constructed by a municipally approved septic tank
manufacturer.
2. The following pipe materials are approved for use in septic system
installations in the Municipality of Anchorage:
Cast Iron (perforated and solid), ASTM D3034 or P.V.C. (perforated and
solid), ASTM F810 or H.D.P.E. (perforated, but not solid) and ASTM D2662
or A.B.S. (perforated and solid).
3. Insulation shall be at least 2" thick extruded direct burial polystyrene (Dow
Chemical Co. Styrofoam HI or equal).
4. Septic tank inlets and outlets shall be fitted with watertight couplings
(Caulder, Femco, or equal).
5. A permeable geotextile fabric (Typar, Mirafi or equal) must be installed
between the final drain rock layer and the native soil layer.
6. All drain rock shall be .5" to 2.5" in diameter with less than 3% passing the
#200 sieve.
INSPECTIONS:
Municipal Ordinance requires a minimum of two inspections. These inspections
must be conducted under the supervision of a professional engineer registered
in the State of Alaska. The first inspection must be conducted after the
excavation of trenches, beds or pits and before the installation of any gravel. A
septic tank may be set in place, but may not be backfilled.
The second inspection must be conducted after the placement of the geotextile
fabric, gravel, distribution piping, standpipes, cleanouts and insulation. No
backfill should be in place at the time of inspection.
Contractor shall provide a copy of all field survey layout and construction notes
for use in preparing the certified as -built of the completed system.
Municipality of Anchorage Page of 3
DEPARTMENT OF HEALTH AND HUMAN SERVICES
ENVIRONMENTAL SERVICES DIVISION
P.O. Box 196650 • Anchorage, Alaska 99519-6650 • Telephone: 343-4744
On-Site Wastewater Disposal System and/or Well Inspection Report
Permit Number: 5 940 33 PID Number: Q091— Qi !i - CA
Name:
�
Wastewater System: XNew Upgrade
F
.
Addres : ^ ,. • d`
ABSORPTION FIELD
Phone
vi
No. of$pdrooms:.
•'�ij
O Deep Trench O Shallow Trench Xeed O Mound ❑ Other
n 0
LEGAL DESCRIPTION
Soil Rating: 0
Total Dep'! lOrrori Iyal grade:
GPD/S Ft.
�
Lot: Bloc Subdivision• ..
Depth to pipe bottom Irom original grade'
Gravel depth beneath pipe
Township:
Range: Section:
Fill added above ongin ] grade:
Gravel length:
, Ft
Ft.
WELL: ❑New ❑Upgrade
'
Gravel width:
`7
Number of lines:
Distance between lines:
w
Ft.
Ft.
Classification (Private. A.9.C):
Total Depth: -
Cased To:
I
Total absorption area:
5 U
Pip�materlal:
- Ft.
Ft.
Ft.
Driller.
Date Drilled:
Static Water Level:
Insl)alterw
Date Installed:
Yield:
Pump Seta:
Cs>,ng Height Above Ground:
TANK
GPM
Ft.
Ft.
SEPARATION
DISTANCES
Xseptic (3 Holding 0S.T.E.P.
To
Uptk
Absorption
Uh
HoldingbikMnv&t
Manufacturer.
Capacity In gallons:
From
Tank
Field
Station
Tank
S•w•runas
jc2�'
Welt
/Ui
1O 77
��
.��
5Z
MatenAh_ r�
Number of Compartments:
walee
107
40'
LIFT STATION
Line
r
�o
r
5o'
�
Size In gallon
Manutacturor.
.
Foundation
r
9
/
i
v
_ //�
"Pump on" level at:
_
Pu _ -1!"e a :
High water alarm at:
1 O
'\
I
/
Curtain
-
Pump Make a Model
Electrical Inspections performed by
Drain
Remarks: O x i5+/7
BENCH MARK
Location and Description:
!
/�e r /��)
�nAssumed Elevation:
(r) Ft
ENGINEER'S SEAL
�OFAI-
Inspections performed by: � �' 5� ���ates: lct_ �
• l�
r°°...� 7�I •1 ••'
�. ✓!j. �.." ( a
2nd —c:
JOmcs F. S'c�inoro%
Department of Healt an-di- l�uman5ervices appro al
c'• OF 1517E
j.,•
9F
. Ic=s-l�� c r.� .2
Reviewed and approved by ,� Dates3/s!!
PP-JFE551CY1P��
�`\V\\\\tri
72-013 (RM. arae) MOA 25
Permit No. S W ? A0332- Page Z- of
Municipality of Anchorage
DEPARTMENT OF HEALTH AND HUMAN SERVICES
ENVIRONMENTAL SERVICES DIVISION
P.O. Box 196650 • Anchorage, Alaska 99519-6650 • Telephone: 343-4744
On -Site Wastewater Disposal System and/or Well Inspection Report
Legal Description: Lo T- 18 D L-8 T/ MBER L UX No. l PID No.:
72-013A(1/93)'
C.•-
... .... ..... ..... ... ...... ....... ... .... ..... ... ... .... ........ ... ........... ....... .......... ... ... ... ... ... ...... ... ..... o..... ... ......... ... ... ... ... ... .... ... .<.........................................
:................................................ .........
...............................................................................
Wel1
J�CI�j�
r 1� OL4
q /iCs
2.y
J --.!3
1 Y 3Qcc>•, 4�� orf, Praih
,
an
J
, G.p.
_............_...._.._..� ._f.....1 ...._...............:..............._...._..._PL..',py�.._........._............................._......__._
_...
...._.__.............._.
-
��
Pr
t000 Gal 5 i eel
..........................._a°..il._4,.5..........._......................................_............:....._..;............................ _............. .................
................
se- P4-ic7;4
....... _............................................................................. _. _.............. _. _.......
ENGINfE@j>S SEAL
! of iIL �°t,
AZ u I LT S1
s.►
.............'dv
jW
. H....0 •ap'�r..ue...u. a1
..• • !cines F. �izc:no.o .� � �
1517 E t i
72-013A(1/93)'
Permit No. SWg4033Z Page J of_-�
Municipality of Anchorage
DEPARTMENT OF HEALTH AND HUMAN SERVICES
ENVIRONMENTAL SERVICES DIVISION
P.O. Box 196650 • Anchorage, Alaska 99519-6650 • Telephone: 343-4744
On -Site Wastewater Disposal System and/or Well Inspection Report
Legal Description: i_ If 3 R L, B 7-1 M 8ELR L V,X "�'[ PID No.:
Cones lab, SA
140V561--
.................. .:......... ............................
>CI.R976 '
ire
R 6oTT' TEST 966
72-013 a (11"
t
Ge
G'eJ
s;de
T e,
ENGINEER'S SEAL
P ••' ••qst J
r` Jamin F. zcmoro .' W
iP •. A' 1517E : v
PAGE 1 OF 1
MUNICIPALITY OF ANCHORAGE /?/ L
DEPARTMENT OF HEALTH AND HUMAN SERVICES f(J
P.O. BOX 196650, 825 "L" STREET, ROOM 502
ANCHORAGE, ALASKA 99519-6650 911b© lQ:rDr4u ln-�-
ON-SITE WASTEWATER DISPOSAL SYSTEM (UPGRADE) PERMIT
PERMIT NUMBER:SW940332 DATE ISSUED: 9/02/94
DESIGN ENGINEER:JAMES SIZEMOORE & ASSOCIATES EXPIRATION DATE: 9/02/95
OWNER NAME:REGNART RONALD I &
OWNER ADDRESS:4900 RABBIT CREEK RD
ANCHORAGE, AK 99506
PARCEL ID:01827108
LEGAL DESCRIPTION: TIMBERLUX #1 BLK B IT 1B
LOT SIZE: 108116 (SQ. FT.)
NUMBER OF BEDROOMS: 3 THIS PERMIT: 3
THIS PERMIT IS FOR THE CONTRUCTION OF:
DISPOSAL FIELD SYSTEM
ALL CONSTRUCTION MUST BE IN ACCORDANCE WITH:
1. THE ATTACHED APPROVED DESIGN.
2. ALL REQUIREMENTS SPECIFIED IN ANCHORAGE MUNICIPAL CODE CHAPTERS
15.55 AND 15.65 AND THE STATE OF ALASKA WASTEWATER DISPOSAL
REGULATIONS (18AAC72) AND DRINKING WATER REGULATIONS (18AAC80).
3. THE ENGINEER MUST NOTIFY DHHS AT LEAST 2 HOURS
PRIOR TO EACH INSPECTION. PROVIDE NOTIFICATION BY
CALLING 343-4744 (24 HOURS) .
4. FROM OCTOBER 15 TO APRIL 15 A SUBSURFACE SOIL
ABSORPTION SYSTEM UNDER CONSTRUCTION DURING FREEZING
WEATHER MUST BE EITHER:
A. OPENED AND CLOSED ON THE SAME DAY
B. COVERED, SEALED AND HEATED TO PREVENT FREEZING
5. THE FOLLOWING SPECIAL PROVISIONS.
SPECIAL Prl
RECEIVED
ISSUED BY:
DATE
/iv/Ias�L/I l�
Neu)
I
I -V C R r- F--i�- T):-____--
9
LI
—5 E,- c -F i C- TI -S, c , 0,
1501,01 f ipe
C r 110
0,
5 1 TEL PLA N
N
-l-15 BLhBjTIME;ERLUA
5 U B 13, dJ'N Fr NO. I
SEPT rc- SYS TF -M UPGRADI
-:. 15 -1 T E- P L, N N- --
JAME�5'-'31ZEMORE Scale
� AS S DC.
le-
�ASSDC- P\Wcti, 11"=co'
xu L&Ti._Ifl dl-_
�l Tg3e
m AA 9 ---1T 1 2
,o;�'Il \
.3 0 �- o -�• a s t�
�G.GS�`JC
t
Iy
,71
ti lops
xu L&Ti._Ifl dl-_
�l Tg3e
m AA 9 ---1T 1 2
,o;�'Il \
II II �I
Monitor "{ u e:.
I I
rr �I II II r'osS T Con,
So I tdr,� Pe +o Pe� r -P
II ,I II
P+iC.ih
-JA
oU lol e. C.0
Mon. Tu 6e�I-I-9-9 7 -
l'-o`� So•vVC.r Roc.Ar
45 'meq Z
_ C T I ON. -.A_=A
L) B D LK 13 TIM8E.F\LUX
'5u -BD., UNITN0,1
_SEPTIC SY5TEM UFGRAD
PLANT sEc.T(ON
'JAMES 5l�£Iv10R£ `` I�c�.l�.
-4'A-55 06, R Nc 11 - 1 ": 60
V,OITD -�c
X\3,1 -138W F O N -j 8 8( I
y.Ol��T1V1U VQaUE�
kAi `'P-19
";�"
i
co
i
133
V,OITD -�c
X\3,1 -138W F O N -j 8 8( I
y.Ol��T1V1U VQaUE�
kAi `'P-19
";�"
James Sizemore & Associates
Civil Engineers &
Surveyors
6410 Switzerland Drive Anchorage. AK 99516
(907) 345-1572
WASTEWATER DISPOSAL SYSTEM SPECIFICATIONS
LOT 1B. BLOCK B1
TIMBERLUX SUBD. UNIT NO. 1
1.0 GENERAL:
1.1 The scope of the project consists of installation of a
new 15' by 38' bed drainfield to replace an existing timber crib
disposal field. The existing septioc tank will be inspected
during the installation of the drainline from the septic tank to
the new drainfield, and if the existing tank is rusted out, it
will be replaced.
1.2 Construction shall be as shown on the approved site
plan and design drawings. Deviations from the drawings shall be
co-ordinated and approved by the engineer conducting the
inspections.
1.3 All construction procedures and material used to
construct the system shall comply with Municipal and State
regulations.
1.4 Unless specifically agreed otherwise, the homeowner
shall be responsible for finish grading areas after the soil is
compacted. Placement of topsoil and reseeding all areas
disturbed by construction is also the responsibility of the
homeowneer.
2.0 SEPTIC TANK:
2.1 Should a new septic tank be necessary, the replacement
tank whall be a 1000 gallon septic tank and shall conform to the
Municipality of Anchorage regulations.
2.2 The septic tank shall be set level and shall be bedded
as necessary to prevent settling or shifting of the tank.
2.3 All pipe connections to the septic tank shall be
equipped with waterproof mechanical couplings. A cleanout shall
b e installed within 5 feet of the house foundation. A double
cleanout whall be installed within 5 feet downstream of the
septic tank.
3.0 SOIL ABSORPTION DRAINFIELD:
3.1 The soil absorption drainfield shall be a bed type
constructed to the dimensions shown on the drawings. The bottom
of fthe 15' by 38' bed shall be excavated to a depth 3' below the
original ground level. The bottom shall be excavated level.
3.3 A total of 1.0 feet of sewer rock shall be placed over
the excavated area. The perforated distribution pipes shall be
spaced as shown on the drawings and at least 6 inches of sewer
rock shall be beneath the invert, with the pipes being placed
level. Sewer rock whall be 0.5 - 2.5" screened gravel, with less
than 3 8 passing the #200 sieve.
3.4 Cleanout pipes and monitor tubes shall be 4" diameter
and installed in locations shown on the drawings. The portion of
the monitor tube extending through the sewer rock shall be
perforated.
3.5 Approved filter fabric shall be placed over the top
surface of the sewer rock. A minimum of 2 feet of soil cover is
to be placed over the filter fabric. If the soil cover thickness
is less than 3 feet, two inches of rigid, burial type insulation
will be placed over the entire top surface of the sewer rock.
4.0 INSPECTIONS:
4.1 A minimum of three engineering inspections will be
required during construction of the system. One after setting of
the septic tank, one after excavation of the bed area prior to
placement of the filter sand, and one after placement of the
distribution piping. In addition to the three mandatory
inspections it is suggested that prior to start of construction
that the contractor and the engineer hold a site meeting to
discuss the project.
4. The contractor shall coordinate with the engineer at
least 24 hours prior to start of construction.
PROBABLE IMPACTS TO ADJACENT PROPERTIES
A) WELLS:
The proposed disposal system is designed in accordance with
the current 1994 Municipal wastewater Disposal Regulations. The
proposed system replaces a timber crib that was constructed in
the mid 1960's. Since the new disposal system has a septic tank
for the solids, and the disposal bed has the proper separation
between the bottom of the bed and the ground water table, and the
separation distances from thje wells on adjacent properties is
greaterr than 100 ft., the possible impact on the adjacent wells
should be less than the existing timber crib.
B) WASTEWATER SYSTEMS
The size of this lot should minimize the impact on adjacent
wastewater systems.
C) RESERVED SPACE/SURFACE AND SUBSURFACE
There is enough space on this lot to put in another
replacement system and still maintain the required protective
radiaa between wells and the disposal system.
D) DRAINAGE
The location of the disposal system will not interfere with
any drainage. The area disturbed during construction of the
system will be graded and sloped so as to not pond water.
�reNGINEER' SEAL)
l• jr� Municipality of Anchorage
ghr�' DEPARTMENT OF HEALTH 6 HUMAN SERVICES
825 "L" Street, Anchorage, Alaska 99502-0650 a f
SOILS LOG — PERCOLATION TEST
PERFORMED FOR: I 1 l r/C�/ / 'Rei=•••�'-•.`;'J�
DATE PERFORMED:
ZV
LEGAL DESCRIPTION: L I S BL,{�- 77, ✓nI I0& 14, Range, Section: R3Lu
IFE�f uR.11 Yl
1 y�
2 C-obbfe-**7".1
3av['Ily, !-(race-
4
5
0
7
91'�— fE2,n 5-e,✓ r
10 WAS GROUND WATER ye s
ENCOUNTERED?
IF AT WHAT 9, —o ' P
DEPTH i %
12 DEPTH?
E
Depth to Water Ager�j
13 mmit"ing? Dae: t -V
14
15
16
17
18
19
20
COMMENTS
Reading Date Gross Net
Time Time
Depth to
Water /
Net
Drop
e
%
=moi`^
2Z
12
PERCOLATION RATE 4. Z- (minutesnnch) PERC HOLE DIAMETER
TEST RUN BETWEEN FT AND FT
PERFORMED BY: �' C� n�� '�— �' - CERTIFY THAT HIS TEST WAS PERFORMED IN
ACCORDANCE WITH ALLSTATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE. DATE:
72-008 (Rev. Mas)
=:1 Vo
MUNICIPALITY OF ANCHORAGE
- • - •DEPARTMENT,OF HEALTH & HUMAN SERVICES
Division of Environmental Seryices
On -Site Services Section
P.O. Box 196650 Anchorage, Alaska 99519-6650
343-4744.
CERTIFICATE OF HEALTH AUTHORITY, .. .
APPROVAL FOR A SINGLE FAMILY DWELLING
Parcel l.D.# t�18-x'11-08 HAA#. HARticbrta. -
1.
-GENERAL INFORMATION,
_Complete: legal -description !/M 85 R LUX SU g p
U)V 17- /V0,
Location (site address or directions) '
..,Property owner.- Day phone
Mailing address`
Lending agency Day phone
Mailing address
Agent - Day phone
'Address
Unless otherwise requested, HAA will be hgld or pickup, s
2 _.,NUMBER .OFBEDROOMS
•--3. -TYPE OF.WATER SUPPLY:.—__..---
.......
UPPLY .— ...-..._ _ Individual well
Communitywell,_•
Y.
--- _ ^Public water �_ ��, = lh `
_. .. NOTE: . if community, well system; provide written_confirmation from Slate_AD_�C fittest- � %
Ing to the legality and status of system.
4. TYPE OF WASTEWATER DISPOSAL: " "
< Individual on-site W Ey r _�� %-�c �C'%•
Holding tank ,A A
1
,Community on-Sitev
..7 •. S T,' -^:1f': ?. L:[c") , y': ,a 7 at.. iZLL^ii.. L .i njJrm
Public sewer,Al
_ t
NOTE: if communitywastewater system, provide written confirmation from State ADEC
attesting to the legality and status of system.
rxassln«.1N,) hon, MOAN21
S. STATEMENT OF INSPECTION _ BY ENGINEER .,.
As certified by my seal affixed hereto and as of the validation date shown below, I verify that my'
Investigation of this Health Authority Approval application shows thafthe on-site water supply
and/or wastewater disposal system is safe, functional and adequate for the number of bedrooms
and type of structure indicated herein.I further verify that based on the information obtained from
the Municipality of Anchorage files and from my Investigation and inspection, the on-site water
supply and/or wastewater disposal system is In with all Municipal and State codes,
ordinances, and regulations in effect on the date of this inspection.
" "Name of Firm ("`o1:�e�' Gii�lr-/� fitS�C ......Phone 3 > 7
�^�O i
Address ~R.
� 2 QS
Engineer's signature/ Date
,�•► OF
--------- — _.... _.. _--�r
6 DHHS SIGNATURE -- -- U' e tsv t
A roved for bedrooms - - .l1tP •««.••A��
PP \\R�FE551CN e
•, , ._Disapproved
Conditional approval for t�°' a° a bedrooms; with the following stipulations
t (Additional Comments
\\. I'A
7, l `) '" � .� • '.:��''. ..., i.. _ . 7.75' . `Q
By:,
Data
The Municipality of Anchorage Department`of Health and Human Services (DHHS) Issues Health Authority
Approval Certificates based only upon the representations given in.paragraph_5 above by an Independent
professional engineer registered in the State of Alaska. The DHHS does this as a courtesy to purchasers of homes
and their lending institutions in order to satisfy certain federal and state requirements. Employees of DHHS do not
conduct inspections or analyze data before a certificate is Issued. The Municipality of Arichorage isnot
responsible for errors or omissions in the professional engineees work.' ` ` -'
nets m•+. +,nt 8K MOA m
Legal
A. Well Data
® Municipality of Anchorage
Department of Health and Human Services
HEALTH AUTHORITY APPROVAL CHECKLIST
f1r/
Well type 19h v a is If A, B, or C, attach ADEC letter. ADEC water system number
Log present (YM) /`i Date completed Driller
Total depth 3 118/ Cased to > / Oo Casing height /Z-
Sanitary seat (YM) y Wires properly protected (YM)
FROM WELL LOG
Date of test
Static water level
Well flow
Pump levetl
SEPARATION
SEPARATION DISTANCES FROM WELL TO:
SeptWholding tank on lot O Z ; On adjacent lots } Z%©
f
Absorption field on lot / r) : On adjacent lots >-
Public sewer main N f A Public sewer manhole/cleanout
Sewer service line -7-5/ Petroleum tank A% OSE
WATER SAMPLE RESULTS:
Coliform 0 Nitrate 1,rq-1 Other bacteria C:)
Date of sample: J,-74, / 75 Collected by: J-
B. SEPTICIHOLDING TANK DATA icy
Date installed Se, % Y4 Tank size CC(-) 6-0/ Compartments Z
Cleanouts (Y/N)._y : Foundation cleanout (YM) y Depression (Y/N) r
High water alarm (YIN)'- - IV44 Alarm tested (YM)
Date of pumping ' /VCI;Y 7 2 P T Pumper
SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK TO:
Well(s) on lot I O L ( On adjacent lots �� �/ Foundation l�0
To property line ?CO) r Absorption field
Surface water/drainage > / (go
7 Z
Water main/service line / 00
T2-0 r.W)•Fmnt CONTINUED ON BACK PAGE
T
U.,
L'
AT INSPECTION
fmn
T
E
�e b 7 P?
m
N
g
°C
m
3 6
�—
ao
z 7 9.p -m.
rn
",
o
z
z
SeptWholding tank on lot O Z ; On adjacent lots } Z%©
f
Absorption field on lot / r) : On adjacent lots >-
Public sewer main N f A Public sewer manhole/cleanout
Sewer service line -7-5/ Petroleum tank A% OSE
WATER SAMPLE RESULTS:
Coliform 0 Nitrate 1,rq-1 Other bacteria C:)
Date of sample: J,-74, / 75 Collected by: J-
B. SEPTICIHOLDING TANK DATA icy
Date installed Se, % Y4 Tank size CC(-) 6-0/ Compartments Z
Cleanouts (Y/N)._y : Foundation cleanout (YM) y Depression (Y/N) r
High water alarm (YIN)'- - IV44 Alarm tested (YM)
Date of pumping ' /VCI;Y 7 2 P T Pumper
SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK TO:
Well(s) on lot I O L ( On adjacent lots �� �/ Foundation l�0
To property line ?CO) r Absorption field
Surface water/drainage > / (go
7 Z
Water main/service line / 00
T2-0 r.W)•Fmnt CONTINUED ON BACK PAGE
C. LIFT STATION
Date installed Manufacturer—
Size
anufacturer_
S¢e in gallons�
Vent (Y/N) Py
High water alarm level
Meets MOA electrical codes (YM)
SEPARAT�DISTANE-FROM
Weil�WE
D. ABSORPTION FIELD DATA
on' level
tested
LIFT STATION TO:
Level at
On adjacent lots Surface water
Date installed I& I %� Soil rating (GPD/Ft) 0-6 System type aN�
Length �J r Width I Gravel thickness Total depth- �, /
Total absorption area 5 % Cleanout present (Y/N) _Depression over field (Y/M / V
r/
Date of adequacy test Feb• -7 %5 Results (pass/fail) f" for 73 Bedrooms
Water level In absorption field before test N� �� After test
Peroxide treatment (past 12 months) (Y/N) Bctl Sy5fe-71K yes, give date
SEPARATION DISTANCE FROM ABSORPTION FIELD TO:
Well on lot r On adjacent lots O6 Property line
To building foundation To existing or abandoned system on lot �L
On adjacent lots > �J6 r Cutbank i)01? a Water maWserv'ice line ? !toot
Surface water Driveway, parkingNehicle storage area
Curtain drain nN0/2 e
E. ENGINEERS CERTIFICATION
I certify that I have checked, verified, or conformed to all MOA and HAA guidelines in effect on the date of this inspection.
Signatuf �'Q— _ r ..: l •e,�
Enginee(s Name..Y n? /%-i« �!-�/�/�%'� r� .......� =ZITj>
Date
NAA Fee $ c� -
Date of Payment a /.---
Receipt
zReceipt Number -717 ��00
11-026 (=)' Back
Waiver Fee $
Date of Payment
Receipt Number
ez� REQUEST FOR APPR.OVA.L OF
INDIVIDUAL SEWAGE AND WATER. FACILITIES
(Fill out in Triplicate)
✓G/
1. 13aeo of person requesting approval
2. ttanw of prop
3. Legal descri
CT
4, Number'of. bedrooms in house_, �� /" Z 41X
S. Water Analysis:
a. Bacterial
b. Detergent
6. Well data: /%✓/
a. Type��//-/�'��
b. Depth_
r
1. ) `G
c. Casing Size
o"�n� o"
d. Distance from well to closest existing or proposed: /!!j
1. Sewer line e c, GGG���
2. Septic tank 1p / j
3. Seepage Area ZQ L /,
4, Cesspool'
i
S. Property Line
6. Other sources of possible contamination, i.e., creeks, lakes,
houses, barn, drainage ditch, etc. /0,0/7
7, Sewage disposal system.
a. Age of system �L�orJ
b. Septic tank capacity in gallons /Zo tt
c. Name of septic tank manufacturgr
1. If "home made" show diagram on reverse side of this form.
d: Disposal field or seepage pit size and type
1. Distance to property line 6 �{- to house foundation
P. Percolation, Test results
f. Percolation Test performed by
4 Use the reverse side of this form to show diafram. Diagram should include
the fojlowine information: property lines; -well location, house location,
n�rt.ic tank location, disposal area location, location of percolation test,
a:,d direction of Around slope.
9. The lufornation on this form is true and correct to the best of my knowledge.
Signature of Applicant Date Signed
TO BE FILLED OUT BY HEALTH DEPARTMENT PEPSOHHEL
T�Ine above described sanitary facilities are hereby approved, subject to the
'ollowinp conditions:
Conditions: ✓flG%L�i
F7
The above described sanitary facilities are disapproved for the following
reasons:
Approval is valid for one year following the date of approval.
CPJ:cw