Loading...
HomeMy WebLinkAboutHYLEN CREST #3 BLK 6 LT 4Hylen Crest #3 Block 6 Lot 4 #050-474-30 MUNICIPALITY OF ANCHORAGE On -Site Water & Wastewater Program PO Box 196650 4700 Elmore Road Anchorage, Alaska 99519-6650 Phone: (907) 343-7904 Fax: (907) 343-7997 http://www.muni.org/onsite On -Site Wastewater Disposal System Permit Permit Number: OSP241084 Work Type: SepticTank Upgrade Tax Code Number: 05047430000 Site Legal Address: HYLEN CREST #3 BLK 6 LT 4 G:0057 Site Mailing Address: 10315 STEWART DR, Eagle River Owner: TYMITZ PETER A & Design Engineer: VEI CONSULTANTS This permit is for the construction of: Effective Date Expiration Date cnt C , Depa]-tuiell t Lot Size in Sq Ft: Total Bedrooms: 5/13/2024 5/13/2025 20764 ❑ Disposal Field Q Septic Tank ❑ Holding Tank ❑ Privy ❑ Private Well ❑ Water Storage All construction shall be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80) 3. The wastewater code requires inspections during the installation. The engineer shall notify the Development Services Department per AMC 15.65. Provide notification by calling (907) 343-7904 (24/7). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather shall be either: a. Opened and Closed on the same day, or b. Covered, sealed, and heated to prevent freezing Special Provisions: • Prior to installing the tank, locate the edge of the bed to ensure that the 5' separation will be met. • The effluent pipe may not cross the property line. Reroute during construction or get an ingress/egress easement recorded. :i Ree Bq: ,J C1!51 (A et^ 4, V 2�_r Date: Issued By: Date: �73 �2 G� 3 1��/IEIUNn PAU d Y OF ANCHORAGE -O \ Il Development Services Department '` r ,' Phone- 907-343-7904 On -Site Water & Wastewater Section - Fax: 907-343-7997 ON-SITE SEPTIC/WELL PERMIT APPLICATION Parcel I.D. 050-474-30-000 Property owner(s) Peter Tymitz & Richenda Sandlin-Tymitz Mailing address 10315 Stewart Drive, Eagle River, AK 99577 Site address Same Day phone 505-359-1884 5o5-3Sg.-r881 Legal description (Sub'd., Block & Lot) Lot 4, Block 6, Hylen Crest #3 Legal description (Township, Range & Section) Section 8, T14N, R1 W, SM Lot Size 20,764 Sq. Ft. Number of Bedrooms 3 APPLICATION IS FOR: APPLICATION IS AN: TYPE OF DWELLING: (® all that apply) Absorption Field ❑ Initial ❑ Single Family (SF) El Septic Tank El Upgrade El(w/wo ADU) Holding Tank El Renewal❑ (D) ElRenewal Privy ❑ Multiple Dwellings ❑ (SF and/or D) Private Well ❑ Water Storage ❑ THIS APPLICATION INCLUDES A WAIVER REQUEST FOR: Distance: I certify that the above information correct. I further certify that this is in accordance with applicable Municipal Codes. , (Signature roperty ownerpyuthorized agent) Permit/Rush Fees: #-,72!;- Date #- 25Date of Payment: S c 202 Y Receipt Number: 1 1 Permit No. C SP2. y 1Q 8 �j Waiver Fees: Date of Payment: Receipt Number: Waiver No. G:\Development Services\Building Safety\On Site Water and Wastewater\Forms\Client FormsTermit Application.doc Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP241084, Deb Wockenfuss, 05/13/24 Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP241084, Deb Wockenfuss, 05/13/24 Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP241084, Deb Wockenfuss, 05/13/24 Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP241084, Deb Wockenfuss, 05/13/24 72-013 (Rev. 3/781 / MUNICIPALITY OF ANCHORAGE MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH & ENVIRONMENTAL PROTECTION.1 CT HEALTH & •--.:[:LATAE P3;iiECTIvN � II ENVIRONMENTAL ENGINEERING DIVISION % 825 L Street - Anchorage, Alaska 99501 Telephone 264-4720 _ IS84 ` ONSITE SEWAGE DISPOSAL SYSTEM AND/OR WELL INSPECTION REPORT" NAME Pf} NP_ 1 ` r•fyty,t EW PGRADE MAILINGADDRESS.,-,O, JIB ' 6AK�6 LEGAL DESCRIPT O .D LOCATION 0 NO. OF BEDROOMS Q 1�� DISTANC 0: Welt Absorption area r Dwelling PERMIT NO D Y � r z- 17— O .5 PZ Manufacturer I � Material No. of Compartments Wa Nf Liq.c758in gallons IF HOMEMADE: Inside length Width Liquid depth 6Y DISTANCE TO: Well Dwelling PERMIT NO. DZ 2? Fa- Manufacturer Material Liquid capacity in gallons O DISTANCE TO: Well(, Foundation r Nearest lot fine / PERMIT NO. W = � o j W Z No. of lines Length of each line Total length of lines Trench itl hr Distance between lines FZW ntcfms H Top of tile to finish grade Material beneath tile/ Total effective ebsorptWn area O (D inches Y !/ Length Width Depth PERMIT NO. W U n H Wa Type of crib Crib diameter Crib depth Total effective absorption area w DISTANCE TO: Well Building foundation Nearest lot line J Class Depth Driller Distance to lot line PERMIT NO. J DISTANCE TO: Building foundation Sewer line Septic tank Absorption areals) OTHER PIPE MATERIA S TA SOIL TEST RA`, �G Sd O INSTALLER � ,C7 fi REMARKS 1 ¢ ' - k w ouc 'I e- 1)�,Afuk SUN.11111W On t, .. t.'l, J. Cr' f APP OV D/` - ,, arc 1. ow-:.�� DATE LEGAL 72-013 (Rev. 3/781 / CORWIN & ASSOCIA .5, INC. Consulting Engineers 4321 Grape Place Suite 204 ANCHORAGE, ALASKA 99504 JOB len pe� l�li)7 f Pll Y IQl SHEET NO.II Op CALCULATED BY L •O. DATE CHECKED BY DATE �A11 hxn5�4. G,,.a„�DU� n � CORWIN & ASSOCIATES, INC, CONSULTING ENGINEERS 1549 E. TUDOR RD., SUITE 204 ANCHORAGE, ALASKA 99507 (907) 561-6151 September 13, 1984 Mr. Keith Bandt Department of Health & Environmental Protection 825 L Street Anchorage, Alaska 99501 Re: Hylen Crest Subdivision Lot 4, Block b Dear Mr. Bandt: Due to the unfavorable topographic and geologic conditions, as we have discussed, such as extreme slopes, bedrock, etc., it was necessary to install the drain bed five (5) feet from the lot line as shown in the as -built. This was the best alternative for us considering that this area is free of bedrock. The neighboring lot is undeveloped and there is a community water system. We feel that there is no threat to public health or water quality and request that, under the circumstances, a five feet waiver from the lot line be granted. Thank you. CORWIN & ASSOCIATES, INC. �u'c �Qor Laura Ogar (J Environmental Engineer LO:kjh Enclosure �lkc�e� 9/ts/8Y .fit % MUM I C I F='nL. I TY MF- ictPA MFiAC3F= DEPARTMENT OF HEALTH AND ENVIRONMENTAL PROTECTION �O�m 825 L STREET, ANCHORAGE, AY 99501 k 264-4720 G, C3"—E3 I TE E3E=WEFR FaEFZM I T PERMIT NO: 840665 DATE ISSUED: 08/06/84 APPLICANT: STEVEN L. SK,AGGS CONSTRUCTION ADDRESS: PO BOX 670690 CHUGIAK, AK 99567 CONTACT PHONE: 688-2831 LEGAL DESCRIP: SUBDIVISION: HYLEN CREST #3 LOT: 4 BLOCK: 6 SECTION: 8 TOWNSHIP: 14N RANGE: 1W LOT SIZE: 20764 (SQ.FT. OR ACRES) ` MAX BEDROOMS: 3 Listed below are the options available to you in designing your septic system. Choose the option that best fits your site. ** GRAVEL LENGTH > 75 FT. REQUIRES MULTIPLE RUNS (NOT EXCEEDING 75 FT. EACH) ** TANK MUST HAVE AT LEAST TWO COMPARTMENTS - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - I certify that: 1. I am familiar with the requirements for on-site sewers and wells as set forth by the Municipality of Anchorage (MOA) and the State of Alaska. 2. I will install the system in accordance with all MOA codes and regulations, and in compliance with the design criteria of this permit. Z. I will adhere to all MOA and State of Alaska requirements for the set back distances from any existing well, wastewater disposal system or public sewerage system on this or any adjacent or nearby lot. 4. I understand that this permit is valid for a maximum of 3 bedrooms and any enlargement will require an additional permit. IF A LIFT STATION IS INSTALLED IN AN AREA COVERED BY MOA BUILDING CODES, THEN (1) AN ELECTRICAL PERMIT AND INSPECTION MUST BE OBTAINED; (2) AS-BUILTS WILL NOT BE APPROVED WITHOUT AN ELECTRICAL INSPECTION REPORT; AND (3) THE ELECTRICAL WORK. MUST BE DONE BY A LICENSED ELECTRICIAN. SIGNED - J�n, , 11„ 1----c1/„ t,/-�--------- DATE: ✓J��56� 1-t1I--1F=' ----�- APPLICANT: ISSUED BY DATE:-eld-r----- 13EI7 W _ DRA I FV DEPTH TO PIPE BOTTOM (FT.) 4.0 4.0 GRAVEL DEPTH (FT.) 0.5 1.5 TOTAL DEPTH (FT.) 4.5 5.5 GRAVEL WIDTH (FT.) 22.0 5.0 GRAVEL LENGTH (FT.) 42.0 97.0 +�* GRAVEL VOLUME (CU.YDS.)'zmrl TANK SIZE (GALS) 10000.0 ** 1,000.0 SOIL RATING (SQ.FT./BR) 201 206 ** GRAVEL LENGTH > 75 FT. REQUIRES MULTIPLE RUNS (NOT EXCEEDING 75 FT. EACH) ** TANK MUST HAVE AT LEAST TWO COMPARTMENTS - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - I certify that: 1. I am familiar with the requirements for on-site sewers and wells as set forth by the Municipality of Anchorage (MOA) and the State of Alaska. 2. I will install the system in accordance with all MOA codes and regulations, and in compliance with the design criteria of this permit. Z. I will adhere to all MOA and State of Alaska requirements for the set back distances from any existing well, wastewater disposal system or public sewerage system on this or any adjacent or nearby lot. 4. I understand that this permit is valid for a maximum of 3 bedrooms and any enlargement will require an additional permit. IF A LIFT STATION IS INSTALLED IN AN AREA COVERED BY MOA BUILDING CODES, THEN (1) AN ELECTRICAL PERMIT AND INSPECTION MUST BE OBTAINED; (2) AS-BUILTS WILL NOT BE APPROVED WITHOUT AN ELECTRICAL INSPECTION REPORT; AND (3) THE ELECTRICAL WORK. MUST BE DONE BY A LICENSED ELECTRICIAN. SIGNED - J�n, , 11„ 1----c1/„ t,/-�--------- DATE: ✓J��56� 1-t1I--1F=' ----�- APPLICANT: ISSUED BY DATE:-eld-r----- PERFORMED FOR i f MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH AND ENVIRONMENTAL PROTECTION 825 L. Street, Anchorage, Alaska 99501 264-4720 SOILS LOG — PERCOLATION TEST LEGAL DESCRIPTION:_ YQ 1 (.� Af%Er- I, f -TI,- 1 Net 10 ssa. 2 it tpkm Drop 12- 21314 4vsva 3- .L>n 13- 4 4- 14- 5- 56 15 15- 6 ' ,I .60 7 END END a b X n 1. m - gravel Mix • 08 }!3 Sandy y 60me St 9 bz PERFORMED BY: 72-008 (6/79) WAS GROUND WATEfl ENCOUNTERED? IF YES, AT WHAT DEPTH? 1-11 , I., SLOPE wS~ o�SIOG PC PERCOLATION TEST DATE PERFORMED:Ion 1 81114 Reading t Gross Net Depth to Net 10 Time it Water Drop 12- 21314 4vsva lz: .L>n 13- .OBo 14- .10 15 15- 16 16- .60 END END I - sz • 08 }!3 Hit I 1 bz I � - .sy •08 19 . �..• C- 33 20 5 •Ob PERFORMED BY: 72-008 (6/79) WAS GROUND WATEfl ENCOUNTERED? IF YES, AT WHAT DEPTH? 1-11 , I., SLOPE wS~ o�SIOG PC PERCOLATION TEST DATE PERFORMED:Ion 1 81114 Reading Date Gross Net Depth to Net Time Time Water Drop +� 4vsva lz: .L>n .OBo .10 .60 I - sz • 08 }!3 Hit I 1 bz I � - .sy •08 1 � 3Q> 5 •Ob PERCOLATION RATE ( 'S / (minutes/i'ngch) TEST RUN BETWEEN FT AND�7F/T Al OA I / ,-A r -t l . CERTIFIED BY: DATE: 2—g ql eco-vY &q T CORWIN & ASSOCIATES, INC. CONSULTING ENGINEERS 1549 E. TUDOR RD., SUITE 204 ANCHORAGE, ALASKA 99507 (907) 5616151 October 1, 1984 Mr. Keith Bandt Department of Health & Environmental Protection 825 L Street Anchorage, Alaska 99501 Re: Hylen Crest Subdivision Lot 41 Block 6 Dear Mr. Bandt: This is in response to your need for additional information on the design and construction of the on-site sub -surface wastewater disposal system on Lot 4, Block 6, Hylen Crest Subdivision. The lot has slopes varying from moderate to severe. The initial soils test on the lot was performed on May 1, 1984. Ground water was encountered at 9.5 feet. A copy of this test is on record at your office. A permit was issued on this soils test. Construction of the house began in mid July. While excavating for the house foundation, shallow bedrock was encountered. I was called to the property to direct where to locate the second soils test site since the house was then located over the initial test area. In late July, I conferred with you and Robbie Robinson for advice on how to deal with the situation. Robbie told me that if the slope was cut into and the accepting strata was used, a bed could be installed. Since the area above the house was at a slope greater than 258 and fill had been brought in to extend the level for the foundation, I felt that the area next to the house was best to use. This area has an approximate 20% slope. The second soils test was performed on August 6, 1984. No ground water was encountered. The percolation test result was 185 square feet per bedroom. Once excavation began on the bed, which ran against the slope, bedrock was encountered in the northwest corner of the proposed use area. To be able to install the bed in the accepting strata, remain at least 6 feet away from the bedrock and 10 feet away from the house, the design configuration was changed to run with the slope and 5 feet away from the lot line. �' I IYVIPY Mr. Keith Bandt Page Two October 1, 1984 The neighboring property, Lot 5, contains 20,764 square feet with half the lot sloping at 258 or greater. Lets assume that only 10,000 square feet of property is acceptable for any type of development. Assume a 4 bedroom house of 2000 square feet with a garage and driveway of 1000 square feet is constructed, thus leaving 7000 square feet of area available for initial installation and replacement of an on-site wastewater disposal system, minus the 250 square feet taken by the installation of the wastewater disposal system on Lot 4, which is 5 feet from the lot line. In retrospect, I do not feel that placing Lot 4's drainbed where it is inhibits Lot 5's development capabilities, nor does it threaten public health or water quality, and therefore request that the variance be approved. Sincerely, CORWIN & ASSOCIATES, INC. o�°t vo r Laura Ogar Environmental Engineer LO:kjh j,� <4 ,//j Municipality of Anchorage On -Site Water &Wastewater Program (907) 343-7904 Certificate of On.—Site Systems (iso LfI4 30 000 Approval % Parcel I.D.—e'F55e265 Expiration Date: 1. GENERAL INFORMATION Complete legal description Location (site address) Current Property owner(s) Mailing address Real Estate Agent HYLEN CREST #3; BLOCK 6, LOT 4 10315 Stewart Drive *Eagle River 99577 Jacob & Jordan Thomson Day phone 654-3662 Heidi Clement Day phone 2. TYPE OF DWELLING: 0 Single Family (w/wo ADU) ❑ Duplex ❑ Multiple Dwellings (Single Family and/or Duplex) 3. NUMBER OF BEDROOMS: 3 4. TYPE OF WATER SUPPLY: TYPE OF WASTEWATER DISPOSAL: Individual Well ❑ Individual On-site 0 Individual Water Storage ❑ Individual Holding tank ❑ Community ClassWell ❑ Community On-site ❑ Public Water System Public Sewer ❑ waiverNadarm request Distance: Received by:/ v(�i/' v vJ v Date: OOSA to be releasetl b Ne engineer, unless othoWee requested by to engineer. COSA Fee $ 521LO' 00 Waiver Fee $ Date of Payment ) i /n1 1i0 Date of Payment 120 6 Receipt Number Q �9- o 60 Receipt Number COSA# 5,SUOKbj Waiver# 5. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, l verify that my investigation, based on procedures outlined in the Certificate of On -Site Systems Approval Guidelines for this application, shows that the on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation. Name of Firm GARNESS ENGINEERING GROUP, Ltd. Phone Address 3701 E. TUDOR ROAD, SUITE 101 • ANCHORAGE, AK, 99507 Engineers Printed Name JEFFREY A. GARNESS, P.E. Engineer's Comments: In conducdrg Ws evaluation, GEGpoHtletl en ergirreervg evaluaficn of the well endrarseplic system in accordance with the guidelines and regulations eslabeaded by Ne MuniapaldyofMohpage andinduslrypradlces. The mpodedrsinds deindbe Ne mnditlon efthe syslen✓s m the daters ofthe evaluetvn. Separedm distances waremeasured to madthyldethfideki lealums. Hidden defects wenaoachments may and that were not idanlilieddunrg the evaludion.Ths otandenallAe ofeal "lls endways systems depend an a vanalyolvadables including, but notlimded to, sed mpNons, groundestarkrels (Nat may fluctuate during the year), quablyofwuhucb'm (materials and wwknanship), mdthe crater usage tithe lamelyuelrring the systeMs. These conditions can vary, and are otdslde the mnbol cfGEG. Sadsladay fad mi uds do not guarantee futurepedormenco ofthte sysiseve fishable, GEG makes no warranty (express wimplied) regarding the futureperlwmarrca bible well wseplic syslam. GEG makes no sk resenbdm whether an ademstim well ursepdcayslem can be insfatladm the paperty in the evantadherofthe current systems fell. The content ofthis mood is for the sole bamftofthepersWpwtywhomtained GEG. Reliance upon the inlermdken chovided in this report by am otherp rdin ape* including but not limited to subsaguerd propertypurchasers, is riot authorized. In shad, GEGe amm any legaldulyto anyoneother than the persWparywho paid for this report 6. DSD SIGNATURE System #1 Approved for � bedrooms. System #2 Approved for Disapproved. Conditional approval for bedrooms. 337-6179 Date I( I I µ /r4, bedrooms, with the following Original Certificate Date: ( OFA/ttt' "f V110 yyri o ° �`� R o - PROGRA The Municipality orAnchorage Develop,emt Services Division (DSD) issues Certificates of On -Site Systems Approval (COSA) based only upon the representations given in paragraph 5 by an independent professional civil engineer registered in the State of Alaska. The Municipality of Anchorage is not responsible for among or omissions in the professional engineers work. 7. ATTCHMENTS: COSA Checklist Septic System Advisory Well Flow Advisory (Rev. ranvtz) >C._ Nitrate Advisory Arsenic Advisory Other If more than 1 septic system is on the lot: COSA Checklist # _of_ Structure served by this system Certificate of On -Site Systems Approval Checklist Legal Description: HYLEN CREST S/D #3; BLOCK 6, LOT A. WELL DATA Well type Date completed Total depth ft. Date of test Static water level Well production WATER SAMPLE Parcel ID: 050-474-30 PUBLIC WATER If A, B, or C provide PWSID# Sanitary seal (Y/N) Cased to ft. FROM WELL LOG Coliform _-� colonies/100 ml ug./L. B. SEPTIC/HOLDING TANK DATA Nitrate mg./L. Well Log (Y/N) Wires properly protected (Y/N Casing height (ab round) in. AT I CTION ft. 9.p -m. Collected by: Date of sample: 32 YEAR OLD STEEL SEPTIC TANK IS APPROACHING THE END OF ITS USEFUL LIFE Tank Type/Material SEPTIC/STEEL Date installed 9/6/84 Tank size 1000 gal. Number of Compartments E Cleanouts (Y/N) YES Foundation cleanout (Y/N) YES Depression over tank (Y/N) NO High water alarm (Y/N) N/A Date of pumping � - Pumper On ?- s C. ABSORPTION.FIELD DATA BELOW EXISTING GRADE AT MONITORING TUBE Date installed _ 9/6184 Soil rating (g.p.d./Wo '/bd 185 System type BED Length 37 ft. Width 23 ft. Gravel below pipe 0.5 ft. Total depth -7.4 ft. Eff. absorption area 851 ft' Monitoring tube YES Depression over field NO Date of adequacy test 10/28/16 Results (Pass/Fail) PASS For 3 bedrooms Fluid depth in absorption field before test 0 in. Water added 595 gal. New depth"4 in. I Elapsed Time:12oi�_33omin. Final fluid depth3/1_25 in. Absorption rate >= 450 g.p.d. Any rejuvenation treatment (past 12 mo.) (Y/N & type) NONE KNOWN 'If yes, give date "INITIAL 105 GALLONS INTRODUCED CAUSED A RISE OF 2 INCHES. THE NEXT 315 GALLONS CAUSED AN ADDITIONAL RISE OF 2 INCHES. THE NEXT 175 GALLONS INTRODUCED CAUSED NO RISE IN LIQUID LEVEL. MT EXTENDS 6 INCHES BELOW CLEANOUTS AT END OF BED. '"'APPROXIMATLY 3.25" BELOW INVERT OF CLEANOUTS AT END OF BED. I9)ZRf 2C -i If31L•L`I Date installed - Size in gallons Manhole/Access (Y/N "Pump on" level at in. "Pump off level High water alarm level Cycles tested Meets alarm & circuit requirements? E. SEPARATION DISTANCES SEPARATION DISTANCES FROM WELL ON LOT TO: Septic tank/lift station on lot Absorption field on Public sewer main Sewer /septic service PUBLIC WATER On adjacent lots On adjacent lots Publ sewer manhole/cleanout Holding tank Manure/animal excrete storage areas SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK ON LOT TO: Building foundation 5'+ Property line 5'+ ' : Absorption field 5'+ (ASSUMED) Water main 10'+ Water service line 10'+ Surface water 1001+ Wells on adjacent lots 2004 SEPARATION DISTANCE FROM ABSORPTION FIELD ON LOT TO: Property line '0' Building foundation "101+ Water main 10'+ Water service line 10'+ Surface water 100'+ Driveway, parking/vehicle storage 10'+ (ASSUMED) Curtain drain NONE KNOWN Wells on adjacent lots 200'+ F. COMMENTS `WR080021 "PER 1984 INSPECTION REPORT NOTE: DRAINFIELD IS IMMEDIATELY ADJACENT TO A 50% SLOPE AND IT IS UNKNOWN THE EXACT DISTANCE THE EDGE OF THE BED IS IN RELATION TO THE TOP OF THIS SLOPE. IT MAY EVEN AS CLOSE AT V AWAY. IT IS REASONABLE TO BELIEVE THAT THIS CONDITION HAS EXISTED SINCE THE SYSTEM WAS INSTALLED NO DAYLIGHTING OBSERVED. THE ORIGINAL INSTALLATION INSPECTION WAS PERFORMED BY49WROGUOMR LAURA OGAR. G. ENGINEER'S CERTIFICATION I certify that 1 have determined through field inspections and review of Municipal records that the above systems are in conformance with MOA COSA guidelines in effect on this date. Engineer's Printed Name JEFFREY A. GARNESS Date IIIIL{/fto (Rev. 11105) - Municipality of Anchorage • Development Services Department Building Safety Division On -Site Water & Wastewater Program 4700 Braaaw Street P.O. Box 196650 ` Anchorage, AK 99519-6650 www.muni.org/onsite �? (907)343-7904 % CERTIFICATE OF ON-SITE SYSTEMS APPROVAL FOR A SINGLE FAMILY DWELLING Parcel I.D. 050-474-30 COSA# D!JC 1012-77 1. GENERAL INFORMATION Expiration Date: Complete legal description HYLEN CREST S/D #3; BLOCK 6, LOT 4 Location (site address) 10315 STEWART DRIVE * EAGLE RIVER, AK * 99577 Current Property owner(s) SCOTT & SHARON HAYES Day phone Mailing address Lending agency Mailing address Real Estate Agent Mailing address 10315 STEWART DRIVE * EAGLE RIVER, AK * 99577 Day phone SUE BURNSTIN W/ DYNAMIC PROPERTIES Day phone 830-8387 3111 C STREET * ANCHORAGE, AK * 99503 Unless otherwise requested, COSA will be held by DSD for pickup. 2. NUMBER OF BEDROOMS: 3. TYPE OF WATER SUPPLY: TYPE OF WASTEWATER DISPOSAL: Individual Well ❑ Individual On-site 0 Individual Water Storage ❑ Individual Holding tank ❑ Community Class Well ❑ Community On-site ❑ Public Water System 0 Public Sewer ❑ The Municipality of Anchorage Development Services Department (DSD) Issues Certificates of On -Site Systems Approval (COSA) based only upon the representations given in paragraph 4 by an independent professional civil engineer registered in the State of Alaska. Certificates of On -Site Systems Approval are required for the transfer of title (except between spouses) for properties served by a single-family on-site wastewater disposal and/or water supply system. DSD also issues COSAs upon request to homeowners. Certificates of On -Site Systems Approval are valid for 90 days from the date of issue for properties served by a private or Class C well and may be reissued with new water samples. (Certificates may be reissued for a period of up to one year with valid water samples.) Certificates are valid for one year for properties served by Class A or B wells or a public water system. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. 4. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal a fixed hereto and as of the vaii ation datE shown behow, l' d , l verr�y, that ». my investigation, based on procedures outlined in the Certificate of On -Site Systems Approval Guidelines for this application, shows that the on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate for the number of bedrooms and type of structure indicated herein. ! further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation. Name of Firm GARNESS ENGINEERING GROUP, Ltd. Phone 337-6179 Address 3701 E. TUDOR ROAD, SUITE 101 * ANCHORAGE, AK 99507 Engineer's Printed Name JEFFREY A. GARNESS, P.E. Date Engineer's Comments: In conducting this evaluation, GEG, LtD. attempted to provide a thorough, conscientious engineering analysis of the system in accordance with.ADEC and MOA DSD Guidelines & Regulations. The reported results described the performance of the system under the conditions encountered at the time of the test, and separation distances measured to readily identifiable features. The operational life of all wells and septic systems depend on the local soils condition, groundwater levels that may fluctuate during the year, and the water usage of the family being served by the system. These conditions are outside the control of the evaluator of the system. Satisfactory test. results do not guarantee future performance of the system, nor do they guarantee that there are no hidden defects or encroachments. GEG, LTD. can therefore not provide any warranty or future estimate of how long the system will continue to meet the operational requirements of the ADEC or MOA DSD. The content of this report is for the sole benefit of the owner listed above. Any reliance upon or use of this report by any other person or party is not authorized, nor will it confer any legal right whatsoever. 5. DSD SIGNATURE !✓ Approved for bedrooms. Disapproved. � II q`ffri(y A`Q�ss.: �ff CE -79P3 r prof essio��o�' Conditional approval for bedrooms, with the following stipulations: Attachments: COSA Checklist Arsenic Advisory Septic System Advisory Maintenance Agreements Well Flow Advisory Supplemental Engineer's Report Kt''IL ate r%U I iY VTnef (Rev. 11105) ON-SITE y VtIATER AND WASTEWATER PROGRAM Original Certificate Date: % `? " j Municipality of Anchorage • Development Services Departmentr-- V«. g Building Safety Division ` « On -Site Water & Wastewater Program R E T Y 4700 Bragaw Street P.O. Box 196650 Anchorage, AK 99519-6650 www.muni.org/onsite (907) 343-7904 CERTIFICATE OF ON-SITE SYSTEMS APPROVAL CHECKLIST Legal Description: HYLEN CREST #3; BLOCK 6, LOT 4 Parcel ID: (9> �i -!Z ZY� 3 Q A. WELL DATA 1PUBLIC WATER Well type If A, B, or C provide PWS1D# Well Log (Y/N) Date completed Sanitary seal (Y/N) Wires properly protected (Y/N Total depth ft. Cased to ft. Casing height (ab round) in. FROM WELL LOG Date of test Static water level ft. Well production g.p.m. WATER SAMPLE AT ft. Coliform colonies/100 ml. Nitrate mg./L. Other bacteria colonies/100 ml. enic: ug./L. Date of sample: Collected by: B. SEPTIC/HOLDING TANK DATA Tank Type/Material SEPTIC/STEEL Date installed 9/6/1984 Tank size 1000 gala Number of Compartments 2 Cleanouts (Y/N) YES Foundation cleanout (Y/N) YES Depression over tank (Y/N) NO High water alarm (Y/N) N/A Date of pumping 7/30/2010 Pumper JR'S PUMPING C. ABSORPTION FIELD DATA *BELOW ExiSTINGGRADE Date installed 9/6/1984 Soil rating (g.p.ddft2o 2/bdr 185 System type BED Length 37 ft. Width 23 ft. Gravel below pipe 0.5 ft. Total depth *6.9 ft. Eff. absorption area 851 ftZ Monitoring tube YES Depression over field NO Date of adequacy test 10/1/2010 Results (Pass/Fail) PASS For 3 bedrooms Fluid depth in absorption field before test 0 in. Water added 450 gal. New depth 0 in. Elapsed Time: - min. Final fluid depth 0 in. Absorption rate >= 450+ g•p.d. Any rejuvenation treatment (past 12 mo.) (Y/N & type) NONE KNOWN If yes, give date D. LIFT STATION Date installed Size in gallons Manhole/Access (Y/N "Pump on" level at in. "Pump ofP' level Hig;"w" water alarm level at in. Cycles tested Meets alarm & circuit requirements? E. SEPARATION DISTANCES SEPARATION DISTANCES FROM WELL ON LOT TO: Septic tank/lift station on lot Absorption field on lot Public sewer main Sewer /septic service On adjacent On adjacent lots Holding tank PUBLIC WATER manhole/cleanout AAittat containment areas Manure/animal excrete storage areas SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK ON LOT TO: Building foundation 5'+ Property line 5'+ Absorption field 5'+ Water main 10'+ Water service line 10'+ Surface water 100'+ Wells on adjacent lots 200'+ SEPARATION DISTANCE FROM ABSORPTION FIELD ON LOT TO: Property line *0' Building foundation ** 10'+ Water main 10'+ Water service line 10'+ Surface water 100'+ Driveway, parking/vehicle storage 10'+ Curtain drain NONE KNOWN Wells on adjacent lots 200'+ F. COMMENTS *PER EXISTING WAIVER #WR080021. **PER 1984 INSPECTION REPORT. G. ENGINEER'S CERTIFICATION I certify that 1 have determined through field inspections and review of Municipal records that the above systems are in conformance with MOA COSA guidelines in effect on this date. Engineer's Printed Name JEFFREY A. GARNESS Date / o /1, //o �...... .... ........ ... .. ... O y A. am ss p049� CE -795 440��p7of esslOt COSA Fee Waiver Fee $ Date of Payment % Date of Payment Receipt Number ��� 7 g� Receipt Number (Rev. 11/05) c S 89°5.645°E 89.5❑' TAR T DRIVE a THE INFORMATION HEREON IS FOR THE USE OF LENDING INSTITUTIONS SPECIFICALLY TO SHOW ANY CONFLICTS BETWEEN EXISTING STRUCTURES AND PLATTED LOT LINES OR EASEMENTS AND IS NOT TO BE USED FOR POSITIONING ADDITIONAL STRUCTURES OR FENCELINES. EASEMENTS OF RECORD, OTHER THAN THOSE SHOWN ON THE RECORDED PLAT, ARE NOT SHOWN HEREON.(UNLESS INDICATED) NOTE: ANY FENCELINES SHOWN ARE LOCATED APPROXIMATELY AND ARE NOT TO BE USED TO DETERMINE PROPERTY LINES OR LOCATE STRUCTURES. ANY PAVING SHOWN MAY BE APPROXIMATE DUE TO SNOW CONDITIONS. oA,P-c-.-'-- -•'-.-9s4p�1 49TH ............................,�.�y/.� c SHANE A. HOLT.' 0oa LS -69 1 4 4v 1G pF� °•, ,•° OJ�G 4 �R gyp? d7 ��0000�o AS -BUILT SURVEY ( NO CORNERS SET THIS DATE) V. = 30' I HEREBY CERTIFY THAT] HAVE PERFORMED A MORTGAGEE'S INSPECTICN OF THE FOLLOWING DESCRIBED PROPERTY. LOT 4, BLOCK 6, HYLEN CREST NO. 3 ANCHORAGE RECORDING DISTRICT, ALASKA AND THAT THE VISIBLE IMPROVEMENTS SITUATED THEREON ARE WITHIN THE PROPERTY LINES AND NO VISIBLE ENCROACHMENTS EXIST OTHER THAN NOTED. DATED AT ANCHORAGE, ALASKA THIS _22 ND_ DAY OF _APRIL 2008 . HOLT LAND SURVEYING 10733, FB 131-68 TEL. 3465513 Municipality of Anchorage Development Services Department . Building Safety Division „ On -Site Water 8 Wastewater Program 4700 BStreet P.O. Baxox 19 196650650 f Anchorage, AK 99519-6650 www.muni.org/onsite (907) 343-7904 CERTIFICATE OF ON-SITE SYSTEMS APPROVAL FOR A SINGLE FAMILY DWELLING Parcel I.D. 0 ,�D - if 7 N- 3 o COSA# 0 Q 0 1. GENERAL INFORMATION Expiration Date: S -6--- C q Complete legal description Location (site address) Current Property owner(s) Mailing address Lending agency Mailing address Real Estate Agent Mailing address HYLEN CREST #3 BLOCK 6, LOT 4 10315 STEWART DRIVE "EAGLE RIVER. AK PATRICIA OLMSTEAD Day phone 694-3238 10315 STEWART DRIVE 'EAGLE RNER, AK Day phone KATHI OLMSTEAD W/REMAX Day phone 244-8020 16600 CENTERFIELD DRIVE *EAGLE RIVER, AK 99577 Unless otherwise requested, COSA will be held by DSD for pickup. 2. NUMBER OF BEDROOMS: 3 3. TYPE OF WATER SUPPLY: TYPE OF WASTEWATER DISPOSAL: Individual Well ❑ Individual On-site 0 Individual Water Storage ❑ Individual Holding tank ❑ Community Class Well ❑ Community On-site ❑ Public Water System Public Sewer ❑ The Municipality of Anchorage Development Services Department (DSD) Issues Certificates of On -Site Systems Approval (COSA) based only upon the representations given in paragraph 4 by an independent professional civil engineer registered in the State of Alaska. Certificates of On -Site Systems Approval are required for the transfer of title (except between spouses) for properties served by a single-family on-site wastewater disposal and/or water supply system. DSD also issues COSAs upon request to homeowners. Certificates of On -Site Systems Approval are valid for 90 days from the date of issue for properties served by a private or Class C well and may be reissued with new water samples. (Certificates may be reissued for a period of up to one year with valid water samples.) Certificates are valid for one year for properties served by Class A or B wells or a public water system. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. 4. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal axed hereto and as of the validation date shown below, I verify that my investigation, based on procedures outlined in the Certificate of On -Site Systems Approval Guidelines for this application, shows that the on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage riles and from my investigation and Inspection, the on-site water supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation. Name of Firm GARNESS ENGINEERING GROUP, Ltd. I Phone 337-6179 Address 3701 E. TUDOR ROAD, SUITE 101 • ANCHORAGE, AK 99507 Engineer's Printed Name JEFFREY A. GARNESS, P.E. Date L 25 0B Engineer's Comments: In conducting this evaluation, GEG, LID. attempted to provide a thorough, conscientious engineering analysis of the system In accordance with ADEC and MOA DSD Guidelines 8 Regulations. The reported results described the performance of the system under the conditions encountered at the time of the test, and separation distances measured to readily Identifiable features. The operational life of all wells and septic systems depend on the local soils condition, groundwater levels that may fluctuate during the year, and the water usage of the family being served by the system. These conditions are outside the control of the evaluator of the system. Satisfactory test results do not guarantee future performance of the system, nor do they guarantee that there are no hidden defects or encroachments. GEG, LTD. can therefore not provide any warranty or future estimate of how long the system will continue to meet the operational requirements of the ADEC or MOA DSD. The content of this report is for the sole benefit of the owner listed above. Any reliance upon or use of this report by any other person or party is not authorized, nor will It confer any legal right whatsoever. 5. DSD SIGNATURE Approved for -7 bedrooms. Disapproved. Conditional approval for bedrooms, with the fllowing stipulations: Attachments: COSA Checklist Septic System Advisory Well Flow Advisory Nitrate Advisory L/ Arsenic Advisory Maintenance Agreements Supplemental Engineers Reort Other 11 = ON-SITE WATER AND WASTEWATER PROGRAM o• 10111110 S By: ` Original Certificate Date: (R. II M) Municipality of Anchorage —�l Development Services Department Building Safety Division On -Site Water 8 Wastewater Program 4700 Bragaw Street P.O. Box 196650 Anchorage, AK 99519-6650 www.muni.org/onsite (907) 343-7904 CERTIFICATE OF ON-SITE SYSTEMS APPROVAL CHECKLIST Legal Description: HYLEN CREST $3 BLOCK 6, LOT 4 Parcel ID: D 8_30 A. WELL DATA PUBLIC WATER Well type If A, B, or C provide PWSID# N/A Date completed Sanitary seal (Y/N Cased to ft. FROM WELL LOG Date of test ��Ft Static water level Well production Q� g.p.m. WATER SAMPLE RESULTS: Coliform colonies/100 ml. B. SEPTIC/HOLDING TANK DATA Well Log NiT properly protected (YIN) Casing height (above ground) in. AT INSPECTION Nitrate mg./L. Other sample: Collected by: Tank Type/Material SEPTIC/STEEL Tank size 1000 gat. Number of Compartments 2 Date installed 9/6/1984 Cleanouts (Y/N) YES Foundation cleanout (Y/N) YES Depression over tank (Y/N) NO High water alarm (Y/N) N/A Date of pumping 10/27/07 Pumper JR'S PUMPING C. ABSORPTION FIELD DATA BE ow EXISTING GRADE TO BOTTOM OF MT Date installed 9/6/1984 Soil rating (g.p.d./ft'o /bd 185 System type BED Length 37 ft. Width 23 ft. Gravel below pipe 0.5 ft. Total depth +7.41 ft. Eff. absorption area 851 ft' Monitoring tube YES Depression over field NO Date of adequacy test 4/16/2008 Results (Pass/Fail) PASS For 3 bedrooms Fluid depth in absorption field before test DRY In. Water added 500 gal. New depth 2 in. Elapsed Time: 640 min. Final fluid depth DRY in. Absorption rate >= 450+ g_p,d, Any rejuvenation treatment (past 12 mo.) (Y/N & type) NONE KNOWN If yes, give date D. LIFT STATION Date installed Size in gallons Manhole/Access (Y/N "Pump on" level at in. "Pump off" level High water alarm level at in. Cycles tested Meets alarm & circuit requirements? E. SEPARATION DISTANCES SEPARATION DISTANCES FROM WELL ON LOT TO: Septic tankAift station on lot Absorption field on lot Public sewer main Sewer /septic service line PUBLIC WATER On adjacent On adjacent lots manhole/cleanout Holding tank Manure/animal excrete storage areas SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK ON LOT TO: Building foundation 5'+ Property line •0' Absorption field 5'+ Water main 10'+ Water service line 10'+ Surface water 100'+ Wells on adjacent lots 200'+ SEPARATION DISTANCE FROM ABSORPTION FIELD ON LOT TO: Property line '0' Building foundation "10'+ Water main 10'+ Water service line 10'+ Surface water 100'+ Driveway, parking/vehicle storage 10'+ Curtain drain NONE KNOWN Wells on adjacent lots 200'+ F. COMMENTS 'SEE ATTACHED WAIVER LETTER "PER 1984 INSPECTION REPORT G. ENGINEER'S CERTIFICATION I certify that I have determined through field inspections and review of Municipal records that the above systems are in conformance with MOA COSA guidelines in effect on this date. Engineer's Printed Name JEFFREY A. CARNESS Date Lt I ZS/O t?. COSA Fee S 4-� '�6 • Cx.7 Date of Payment Receipt Number. rJ� (Rev. 11105) Waiver Fee sU 1 % 5 . uo Date of Payment 3 0 /J Receipt Number Municipality of Anchorage Development Services Department • re Building Safety Division On -Site Watcr and Wastewater Program 4700 Elmore Street P.O. Boz 196650 Anchorage, AK 99519-6650 www.ci.anchoragc.ak.us (907)343-7904 Waiver Revicw Worksheet WR#: 08002 PID#:050-474-30 HAM 080122 Permit#: Date Received: 4130/08 Legal Description: Helen Crest #3 Block 6 Lot 4 Engineer: Jeff Garness Garness Engineering Group, Ltd.. 3701 E. Tudor Rd.. Suite 101 Anchorage Ak. 99507 Applicant: Patrica Olmstead Waiver Requested: Zero feet separation distance absorption field to property line. Criteria: Geology A. Water Table B. Soil Sorption C. Permeability D. Water Table Gradient E. Horizontal Separation Total: Points: was ...... ............................. ..seen.... .... ..................nesse.... Waiver is Granted: List Conditions or Reasons for above: Waiver is not Granted: Date: By: Name of Reviewer ...................................................... sessenn..e..... 0.ee06e000 Rec#: 4130108 Amount: $175.00 Date Paid: 4130/08 Municipality of Anchorage 1:21. 14ix UNWiNI-Anchoragc,.\Inskn V951I4WO. 471X1 Einmrr ltwiJ I lllin•: (W7043.8MI • Fax: 1!MIi1:03-KCMM1 hllp://a mw.numLor4 31uyor dark Jkyich Development Services Dep.irtnient 5/5/2008 Jeff Gamess Gamess Engineering Group, Ltd. 3701 E. Tudor Rd., Suite 101 Anchorage Ak. 99507 Subject: Waiver Request for Hylen Crest #3 Block 6 Lot 4 Waiver Request #WR080021 Parcel ID #050474-30 IIAA# 080122 Dear Engineer, r,cnt Ucpit runent Your request for a waiver of the required 10 feet horizontal separation from the absorption field to the property line has been approved. The approved separation distance is 0.0 feet. This waiver approval applies to the existing absorption field to property line separation only. Any future upgrade to the on-site wastewater disposal system will require all separation distances be met or another approval from this department. If there are any further concerns or questions regarding this waiver, please call our office at 343-7904. Sincerely, Jeffrey W. Poet Engineering Technician On -Site Water & Wastewater Program Community, Security, Prosperity GARNESS ENGINEERING GROUP, Ltd. CONSULTANTS 8 GENERAL CONTRACTORS April 25, 2008 Municipality of Anchorage Development Service Department On -Site Water & Wastewater Program 4700 Bragaw Street P.O. Box 196650, Anchorage, Ak 99519-6650 (907)343-7904 Ref: Lot Line Waiver for Ilylen Crest #3 14 B6, To whom it may concern: We request that your department issue a 0 -foot lot line waiver from the west property line to the existing drainfield. There is no septic system within 10 feet of the lot line on the adjacent lot. In short there are no concerns in granting this waiver. We are unaware of any adverse impacts this waiver would have on adjacent wells or septic systems. If you have any questions, please contact us at 34A6179. Thank you for your assistance. M.S. 3701 E. Tudor Road, Suite 101 • Anchorage, AK 99507-1259 Ph: (907) 337-6179 0 Fax: (907) 338-3246 • Website: www.gamcssengincering.com #00�, MUNICIPALITY OF ANCHORAGE DIVISION OF ENVIRONMENTAL HEALTH DEPARTMENT OF HEALTH AND ENVIROtZMNTAL PROTECTION APPLICATION FOR HEALTH AUTHORITY APPROVAL CERTIFICATE I / 1. General Information Application Date (a) Legal Description (include lot, blocl, subdivision, section, township, range) n (address or directions) (b) Applicants Applicants Addres ne - (c) Applicant is (check one) Lending Institution ; Ener/builder ; Buyer ; Other M (explain); (d) Lending Institution Telephone Address (e) Real Estate Co. b Agent Address Telephone (f) Mail the HAA to the following address: 2. Type of Residence Single -Family Q Multi -Family M Number of Bedrooms 3 3. Water Supply Individual Well Coumunity Other (describe) Public = Note: If community well system, must have written confirmation from the State Department of Environmental Conservation attesting to the legality and stAtus. 4. Sewage Disposal Onsite Public Community Holding Tank jlote: If community well system, must have written confirmation from the State Department of Environmental Conservation attesting to the legality and status. [Page 1 of 21 5. Engineering Firm Providing Inspections, Testa, File Search Data and Information As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation of this Health Authority Approval shows that the on-site water supply and/or wastewater disposal system is safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that, based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is in compliance with all Municipal and State codes, ordinances, and regula- tions in effect on the date of this inspection. Name of Firm 4"t�_ Y (656o k6 ----.---'Telephone 57'44'k5l Address �- ZQ •� j Date 10 MY '. ------------ (ENGINEER SEAL) 6. DHEP Approval Approved for bedroomsBy _, Date Approved �/ Disapproved /` Condition a ` Terms of Conditional Approval CAUTION THE MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH AND ENVIRO%ZiENTAL PROTECTION (DHEP) ISSUES HEALTH AUTHORITY APPROVAL CERTIFICATES BASED SOLELY UPON THE REPRESEN"L- ATIONS GIVEN IN PARAGRAPH 5 ABOVE BY AN INDEPENDENT PROFESSIONAL ENGINEER REGISTERED IN THE STATE OF ALASKA. THE DHEP DOES THIS AS A COURTESY TO PURCHASERS OF HOMES AND THEIR LENDING INSTITUTIONS IN ORDER TO SATISFY CERTAIN FEDERAL AND STATE REQUIRE- MENTS. EMPLOYEES OF DHEP DO NOT CONDUCT INSPECTIONS OR ANALYZE DATA BEFORE A CERTIFICATE IS ISSUED. THE MUNICIPALITY OF ANCHORAGE IS NOT RESPONSIBLE FOR ERRORS OR OMISSIONS IN THE PROFESSIONAL ENGINEER'S WORK. (DHEP SEAL) RRS/ej/D18 [Page 2 of 21 . 7-19-84 A. WELL DATA MUNICIPALITY OF ANCHORAGE (MOA) HEALTH AUTHORITY APPROVAL (HAA) CHECKLIST - FEBRUARY 1984 Legal Well Classification If A(; B Well Log Present (Y/N) Date CCITT! Total Depth - Cased to Static Water Level Casing Height Above Ground MUNICIPALITY OF ANCHORAGE DEPT. OF HEALTH & . ENVIRONIVIZNTAL PROTECTION SEP1�'184 RECEIVED Pump Set At Depth of Grouting Sanitary Seal on Casing (Y/N) Electrical Wiring in Conduit (Y/N) Depression Around Wbllhead (Y/N) Separation Distances from Wbll: To Septic/Holding Tank on Lot 4',?001 On Adjoining Lots t200� To Nearest Edge of Absorption Field on Lot +2001 ; On Adjoining Lots +ZOO To Nearest Public Sewer Line N�R To Nearest Public Sewer Cleancut/Manhole To Nearest Sewer Service Line on Lot d1A Water Sample Collected By — Date Water Sample Test Results Camlents B. SEPTIC/HOLDING TANK DATA Date installed 10A0 p4. R1 *Size 0 No. of Compartments 7 - Standpipes (Y/N) Air -tight Caps (Y Foundation Cleanout (Y/N) res — Depression over Ta c (Y/N) Alm Date Last Punpe a /a Pumpirg/Maintenanee Contract on File (Y/N) — for Holding Tank High -Water Alarm (Y/N) — Temporary Holding Tank Permit (Y/N) - Separation Distances from Septic/Holding Tank: To Water -Supply Well +ZC)C)' To Building Foundation / 2 To Property Line 201 To Disposal Field /p To Water Main/Service Lire 40, To Stream, Pond, lake, or Major Drainage Course r/00 Comments �-/Lr-yy 9Of, .-Y-Z (Page 1 of 21 2-15-89 C. ABSORPTION FIELD DATA f Soils Rating in Absorption Strata Type of System Design hod Date Installed Length of Field 37 ' Width of Field ' Depth of Field Y Gravel Bed Thickness (o lr('IE_S Square Feet of Absorption Area t7 s� Standpipes Present (YM) S. Depression over Field (YA 6 Late of Last Adequacy Test Results of Last Adequacy Test _ Separation Distance from Absorption Field: To Water -Supply Fie11 'f' ?00' To Property Line To Building Foundation W To Existing or Abandoned System on Lot 4 I_: On Adjoining Lots _ d16: To Water Main/Service Line AIL)' To Cutbank(if present) NA To Stream/Pond/Lake/cr Major Drainage Course +/00 To Driveway, Parking Area, or Vehicle Storage Area Ccmmnts D. LIFT STATION IA Date nsta Size in "^ —_ ()n" High Water Tested for Electrical 1 at Level at Manhole/ s (Y/N) "Puny Off" Le 1 at Vent /N) Cycles curing Ade4uicy Test. Meets MOA ** Check Permitted Bedroom Rating Against HAA Request ** I certify that I have checked, verified, or conformed to all MOA HAA Guidelines in effect on the date of this irspecticn. Signed .ti�p Date 10 1�eI `"+' Conpany 4 MOA No. KBl/d5/s (Page 2 of 21 2-15-84 ,ERS _^ £TI ': fin. i:. +.• ..i G 2-15-84