Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
THERESA MAE LT 1A
Theresa Mae Lot 1 A #015-081-39 Municipality of Anchorage .r Development Services Department Building Safety Division Onsite Water and Wastewater Program, 4700 Elmore Road P.O. Box 196850 Anchorage, AK 99507 Page of www.ci.anchorage.ak.us (907) 343.7904 ON-SITE WASTEWATER DISPOSAL SYSTEM AND/OR WELL INSPECTION REPORT Permit Number. SW080039 PID Number. 015081-39 N.m. Merit Homes Wastewater System: [Z] Nerw ❑ Upgrade P.O. Box 111982 Anchorage, AK 99511 ABSORPTION FIELD pla 334-9233 Numwae.eoorrr 5 Dl)wl` ar OSnrx.r Tnrxli Dew OMa.w Domer SW ' TaroMN mm LEGAL DESCRIPTION A5 GPDF? 9-10 Ft. eadi 15 r 1ot1A DWMmPMw n W"Qw• CrewaepmPruamPin Theresa Mae 5-6 Ft. '4 Fl Tw,Wp Rrge Scam Frw a aprMiywe Gm Larpm. 1-2 Ft. 170 Fr. Well: © New El Upgrade Gnw w.xn 5 NarC.r a ena. z Petrce Pawwn erw 110 FL n Cuu m mr (Pe. A ar Dean a. CI T Cuss o far w6api m an. PM Mr Private 166 Fr. 166 FL 1,700 Ft' ASTM D3034 PVC Dww Dau Cm.G Suoc wren Lew mitiW Dra 1m w Alpine Drilling /6178 69 FL Red Dog Excavating 9/3.5/08 YaaPunp m Cuwgi W%ACow Grano TANK 20 GPM /S(p F,. >1.5 FL SEPARATION DISTANCES 0 Septic ❑ Holding ❑ S.T.E.P. ❑ Other. To Septic Absorption Lilt Holding lublCrPrivilte •o'••r Q.P.Cty From Tank Field Station Tank Sewer Lira Anchorage Tank 1,500 or M.irwi NiniOr a Cmprmru car >100, >100' N/A WA >2V Steel Two (2) swracawr« >100' >100• N/A N/A LIFT STATION Loi i+iw >5' >10' WA N/A Gr •titer •Pump an' IF.r n 'Pump err Mw •t Nqn w.ur r.rm n Foa'oai'o^ >5' >10' N/A N/A n n k Pump Mw 6 Meer EMcmcr iN =l PMomwe q Durum a.n Nona Noted BENCH MARK Lorrum ra D. -Ove Garage Slab ev.um 100..0 FL ;v8l0xG%oStatrnt Inspections performed by: M. Anderson Dates: 1M 913108 4oe pF , p tk 2nd 914 -5108 . •'• Development Services Department Approval OW * 49� V *•P Conditional Approval Date: .b. ... p........ ..NUN. y1 a . -MICHAEL E ANDFASQN v r Reviewed and approved by: gc� Date:. O q mod 14 1111t»� ; " " C? — — 3/U80 83AOHD 0 �— Nmo O I O 6. o ry00�e jr-91l A.K.MDO N N 1 :r�iohrnbh <��asxaaa� I L RWI I o I I I z t7 I I I rn a� F— EL >aW0) > I J o Cl �w� o Q U m W o z I �/y 0 cr Q Q U:Ci roc o /y�� I'�i U n L° o �mC z Og Q I�: n O v W m g EL VI � ® I c ado J W W (n W w 7 N ° E < m I Q W w I , J I � W � pJs C 3 \ O I . •� a I �2- TF I m •ger. � � �' � �; '•• €€• , �. •W i1�A, L:l jz-GIl N•K.ZODO N 4y �'Li ti ` % z j": m e z° 1 Hi i Municipality of Anchorage Page 3 of 3 DEVEOPMENT SERVICES DEPARTMENT 4700 Elmore Road Anchorage, AK. 99519.6655 - 343-7904 On -Site Wastewater Disposal System or Well Inspection Report Permit Number. SWO80039 PID No. 015-081-39 N N UU H N /FY~ 1,500 Gallon Septic Tank 8.5 EAST TRENCH N WEST TRENCH PROFILE AS -BUILT - No Scale .8 .9 MUNICIPALITY OF ANCHORAGE DEVELOPMENT SERVICES DEPARTMENT/BUILDING SAFETY DIVISION ON-SITE WATER AND WASTEWATER PROGRAM 4700 ELMORE ROAD ANCHORAGE, AK 99519 SOILS LOG - PERCOLATION TEST LEGAL DESCRIPTION: LOT IA THERESA MAE SUBDIVISION PERFORMED FOR: MERIT HOMES DATE: 9/4/2008 PROJECT No.: PARCEL ID#: TECHNICIAN: JILL DAVIS DEPTH TEST HOLE 3 Type of Test: Occt) 1 OB/OG SLOPE SITF PAN 2 3 GRAVEL WITH SILT AND SAND 4 I TO 5 SM -GM <5% 6 7 L LOT IA— � • 8 9 BOH WAS GROUNDWATER GROVER DR. ENCOUNTERED? NO 10 IF YES, WHAT DEPTH? L I DEPTH OF WATER 0% AFTER MONITORING: _ DATE: 1 15 16 17 18 19 COMMENTS: DATE READING GROSS TIME (MINUTES) NET TIME (MINUTES) DI pTER F (INCHES) INET DROP (INCHES) 4/7/06 TEST HOLE PRESOAKED PRIOR TO TESTING: 1 1:08 3.50" CHARGE 2 1:38 30 4.25" 0.75' 3 1:39 3.38" CHARGE 4 2:09 30 4.00" 0.62" 5 2:10 3,50" CHARGE 6 2:40 30 4.12" 0.62" PERCOLATION RATE149 _(MINANCH) PERC. HOLE DIA. 6 (INCHES) TEST RUN BETWEEN:: 4_5 FT. and 5_5 FT. PERC. TEST COMPLETED IN SIDEWALL OF TRENCH. I TEST PERFORMED BY: JD I, MICHAEL E. ANDERSON, CERTIFY THAT THIS TEST WAS PERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES ON THIS DATE: 11/15/2008 Development Services Department Building Safety Division f : On -Site Water & Wastewater Program Aw 4700 Elmore Street P.O. Box 196650 Marc Begich Anchorage, AK 99519-6650 Mayor w ,muni.oro/onsite (907)343-7904 Pump Installation Log Well Drilling Permit Number: SW_ Date of Issue: Parcel Identification Number: Replacement Only: YES NO Legal Description Lot 1A Teresa Alae Property Owner Name & Address: Aferit Hontes Pump Installation Date: 8-29-2008 Pump Intake Depth Below Top of Well Casing: 156 feet Pump Manufacturer's Name: Grundfos Pump Model: 15SQE07-180 Pump Size 314 hp Pitless Adapter Burial Depth: 12 feet Pitless Adapter Manufacturer's Name: Campbell B-10 Pitless Adapter Installer: Red Dog Afasonry Well Disinfected Upon Completion? ® Yes ❑ No Method of Disinfection: Recirc Comments: Pump Installer Name: Aarow Pump & Nell Service LLC PO Box 110496,Anchorage, AK. 99511 (907) 346- 9355 Attention: The pump installer shall provide a pump installation log to the DSD within 30 days of pump installation. ■a ■■"Ori :Alpine Drilling 11 ■ ■� we FAX N0. :907 345 0202 Oct.12 2008 03:48AM Pl ALPINE DRILLING & ENTERPRISES Permit Number: #SW080339 Date of Issue: 5-2-08 Parcel Identification Number: 015-081-39 Date Started: 0-&08 Date Completed: 6-6-08 Is well located at approved permit location? ® Yes ❑ No Legal Description: - Theresa Mae Lot 1A Property Owner Name & Address: Merit Homes PO Box 111982 Anchorage. Alaska 99511 Borehole Data: Depth (ft) Method of Drilling ® air rotary ❑ cable tool Soil Type, Thickness 8c' Water Stam From . To Casing type: Steel stick-up 0 2 Wall Thickness: .025 inches gravelly silt silt gravelly silt 2 47 61 47 81 111 Diameter: ¢ inches Depth: 166 feet Liner Type: Diameter: inches Depth: feet Casing stickup above ground: 2 feet Sift grey silty water sand 8 gravel 111 162 162 166 Static water leve! (from Bound level): 69 feet Pumping level: 166 feet after 2 hours pumping 20 gpm Recovery Rate: 20 gpm Method of Testing: &LIff Well Intake Opening Type: ❑ Open End ® Open Hole ❑ Screened Start feet Stopped feet ❑ Perforations Start feet Stopped feet Grout Type: bentonite grarruJes Volume: 2 . Depth: Start.9 feet Stopped.Z feet Pump: Intake Depth feet Pump size hp Brand Name Well Disinfected Upon Completion? ® Yes ❑ No Method of Disinfection: chlorine tablets Comments: Well Driller: Alpine Drilling & Enterprises P.O. Box 110496 Anchorage, AK 99511-0496 Attention: The well driller shall provide a well log to the property owner within 30 days of completion and the property owner or the well driller shall provide a well log to the Development Services Department within 60 days of completion. MUNICIPALITY OF ANCHORAGE p'D Development Services Department p 1 On -Site Water & Wastewater Program 0 4700 South Bragaw Street n P.O. Box 196650, Anchorage, AK 99519.6650 ic (907) 343-7904 ONSITE WASTEWATER DISPOSAL SYSTEM / WATER SUPPLY PERMIT Initial Permit Number: SW080039 Legal Description: THERESA MAE LOT 1A Date Issued: May 02, 2008 Expiration Date: May 02, 2009 Parcel ID: 015-081-39 Design Engineer: 0014 ANDERSON ENGINEERING Site Address: 7144 THERESA MAE Owner Name: MERIT HOMES Lot Size: 40011 SQ. FT. Owner Address: PO BOX 111982 Total Bedrooms: 5 Permit Bedrooms: 5 ANCHORAGE. AK 99511 - This permit is for the construction of: ❑/ Disposal Field Z Septic Tank ❑ Holding Tank ❑ Privy ❑✓ Private Well ❑ Water Storage All construction must be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal Code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72 ) and Drinking Water Regulations (18AAC80 ). 3, The engineer must notify DSO at least 2 hours prior to each inspection. Provide notification by calling (907) 343.7904 ( 24 hours ). ( Not required for a Water Supply Permit only ). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must be either: A. Open and closed on the same day. B. Covered, sealed, and heated to prevent freezing. 5. The following special provisions. i"11 THE PROPOSED SYSTEM IS INA DIFFERENT SOIL STRATUM THAN THE STRATA THAT WAS TESTED. 4 THE ENGINEER NEEDS TO DO AN ADDITIONAL PERCOLATION TEST PRIOR TO THE CONSTRUCTION OF THE SEPTIC FIELD. PLEASE SUBMIT STAMPED AND SIGNED RESULTS FOR ONSITE REVIEW AND APPROVAL PRIOR TO CONSTRUCTION. 12: THE ENGINEER IS TO VERIFY THAT THERE IS NO ORGANICS BELOW 2' ON TH1 PRIOR TO CONSTRUCTION. CONFIRMATION OF THIS IS TO BE SUBMITTED TO OUR DEPARTMENT BEFORE . CONSTRUCTION IS TO BEGIN. Received By: 'hdlg Date: Issued By. A�7�� /Ntk�iy Date: S �g Municipality of Anchorage Development Services Department Building Safety Division On -Site Water and Wastewater Program 4700 Bragaw Street P.O. Box 196650 Anchorage, Alaska 99519-6650 www.muni.org/onsite (907) 343-7904 ON-SITE SEWER/WELL PERMIT APPLICATION FOR A SINGLE FAMILY DWELLING Parcel I.D. 015-061-39 Property owner(s) Merit Homes Day phone 334-9233 M :!:ng 5 -c! -Tress P.O. Box 111962 Anchorage, AK Zip Code 99511 Site address *T 14 L Theresa Mae Circle Anchorage, AK Zip Code 99516 Legal description (Sub'd., Block & Lot) Lot 1A, Theresa Mae Subdivision Legal description (Township, Range & Section) Lot Size 40.011 Sq. Ft. THIS APPLICATION IS FOR (® all that apply): Absorption Field Q Septic Tank El Holding Tank ❑ Privy ❑ Private Well El Water Storage ❑ Number of Bedrooms Five THIS APPLICATION IS AN: Initial Q Upgrade ❑ Renewal ❑ certify that the above information is correct. I further certify that this application is being made for a Single Family Dwelling and is in accordance with applicable Municipal Codes. (Signature of property owner or authorized agent) Permit/Rush Fees: LOn ~ I Waiver Fees: Date of Payment: 4 O Date of Payment: Receipt Number. aLnv� Receipt Number. (Rev. 7 V05) ANDERSON ENGINEERING P.O. BOX 240773 ANCHORAGE, AK 99524 522-7773 677-7766 FAX VA:IkyiEel Z1►Bill ',I DATE: September 4, 2008 TO: Deb Wockenfuss FROM: Mike Anderson, P.E. SUBJECT: Lot 1A, Theresa Mae Subdivision No. 1 Septic System Permit Upgrade Permit No. SWO80039 We have changed the design for the absorption trenches for Lot 1A, Theresa Mae Subdivision to take advantage of better soils found on the lot. The new design includes 2-84' long by 5' wide by 4' effective depth absorption trenches at the location shown. The alignment of the trenches has also been changed to the northwest to southeast alignment to facilitate the additional length required. The surface slope on the lot is very shallow ranging from flat to 3% and the distribution line will be placed at 4' below the surface. The absorption area will remain in the percolation zones and not the organic layer. We verified during our first inspection the organic layer in Test Hole No. 1 does not exceed the 2' depth below the surface. No groundwater was found in either Test Holes No. 1 or 2. Additional percolation tests will be furnished verifying the soils encountered are as good or better than those utilized to design the absorption trench. ANDERSON ENGINEERING P.O. BOX 240773 ANCHORAGE, AK 99524 522-7773 677-7766 (FAX1 April 9, 2008 Municipality of Anchorage Development Services Department On -Site Water and Wastewater Program 4700 South Bragaw Street Anchorage, AK 99519-6650 Subject: Lot 1A, Theresa Mae Subdivision Septic System Design and Permit Application Impacts to Adjacent Properties Dear Onsite Services Engineer: The owner of Lot 1A, Theresa Mae Subdivision intends to construct a new five - bedroom home on the lot. We are therefore requesting a permit be issued for the construction of a new well and septic system to accommodate the home. The attached Site Plan and backup documentation identify the location and configuration of the proposed well and septic system along with the alternate site. Drainage arrows are shown on the site plan showing the grade and direction of flow on the lot. The drainage pattern will not be changed as a result of this project. The test holes placed on the lot in the area of the absorption trench and alternate site indicated silt with sand and gravel. The percolation rate of the soil was determined to be between 31 and 60 minutes per inch. Groundwater was found at a depth of 13' on May 20, 2006. An application rate of .45 gallons per day per square foot was used in the design of the absorption system. We are proposing to place a new 1,500 -gallon septic tank and 2-60' long by 3' wide by 7' effective depth absorption trenches to treat and dispose of the effluent generated in the house. The elevation of the distribution line in the absorption trenches will be 2.0' below the surface and the total depth will be 9.0'. A minimum of 3' of fill or 2" of insulation and 2' of fill will be placed over the absorption trench and 4' over the septic tank.' A flow splitter valve will be placed to insure even flow to each trench. The ground surface on the lot in the area of the absorption trench slopes to the northwest at constant grade approximating 3%. The new trench will be constructed parallel with the slope as much as possible in conformance with Municipal requirements. The new septic system will be constructed a minimum of 100' from all wells and any surface water and 10' the proposed and existing water services in the Lot 1A, Theresa Mae Subdivision April 9, 2008 Page Two area. If the system is constructed in accordance with our design the following statements apply: The system, if constructed as designed, will have no adverse impact on the wells in the area or those to be constructed in the future. 2. The system, if constructed as designed, will have no adverse impact on existing septic systems in the area or those to be constructed in the future. 3. The system, if constructed as designed, will have no adverse impact on reserve space, either surface or subsurface, on any lots located in the area. 4. • s nc system, if constructed as designed, will nave no adverse impact on drainage patterns in the area. The current drainage pattern will be maintained. Sincerely, Michael E. Anderson, P.E. Attachments I'M ALI �- - - 3/980 H3NO80 z° dv I n ••gid'•• � � � , CIS ,lZ'Sll M,K,ZO.00 N ••• \Nq UMS3 3 V '1 ,01 I 7, ------------------------- �I I 1 I I �I R I x �I I ,d > m Luz g< O a IU j I Q cv ao 1 I I o UN I Eg! JI v Q W N SE 1 I 0 o w of N b I 1 1 R J = j � I 1 I j I b I .2a 7837 L I U�%.�0 � M 0o.2 N1N� O'��• JCC° yO� m<n n N xQ I a Egoc � oks 1 JOWolly o:: Ew" I i E oma. o i m ,lL'Sll M,K,LOAO N n N h LOT 1A, THERESA MAE SUBDIVISION DESIGN FACTORS: SYSTEM REQUIREMENTS: Five Bedroom Home —DeepZ Syuem- Perc. Rate: 31 to 60 Min./Inch 1,500 Gallon Septic Tank Application Rate: .45 GPD/SF 4' Drainfield Rock 5 Bedrooms X 150 GPD/.45 GPD/SF (Application Rate) =1,666.7 SF Absorption Area 1,667 SF/5 SF/LF•.5 (Red. Factor) = 166.7 LF Trench Length THEREFORE: Construct 2-84' Long x 5' Wide x 4' Effective Depth Absorption Trench at the Location Shown. Flow Line Elevation in Trench to be 4' Below Original Ground Surface. Total Depth to be 8' Below Existing Ground. Provide 4' Cover Over Septic Tank and 3' Cover Over Absorption Trench. Maintain 100' Separation from Wells In the Area. Natural Backfill 3'6" Geotextile Fabric 6•, O 4" Perforated PVC (Holes Down) 4'0" 5' Drainfield Rock TYPICAL 5' WIDE TRENCH SECTION..,.��•ggq•�� (NO SCALE) . �P,.•• """" NOTE: Grade Area Over Trench to Drain Away. 49U Minimum 6' Separation From Bedrock. ;•••••% •••••• ......- Minimum 4' Separation From Groundwater. ••,.... Minimum 100' Separation From Wells in the Area. MCS LE AMCER" Minimum 100' Separation From Surface Water or Streams.' *isNo�0.� i Municipality of Anchorage Development Services Department •'?1 i:91H ' .4700 South pragaw Street Anchorage, AK 9951 «« SOILS LOG - PERCOLATION TEST •••• ««...... .. - t � �AvatAet a Ah ,FE 431 PERFORMED FOR:_ MERIT HOMES LEGAL DESCRIPTION:_ Theresa Mae Subd., Lot 9A DEPTH (FEET) 1 � ' 2' 3 4 M� 5 �M 6 7 s 9 lJ . DATE PERF " _, SLOPE SITE PLAN 10 j// WAS GROUND WATER - Net Time — Depth4a wateg ►11 f J M ENCOUNT-EF �I 11 a=�ir7G IF YES. AT WHAT DEPTH? r r 12 Depth to Water After - Monitoring? :. .... - I I Dale: '.3 30 Reading Date ' Gniss Time - Net Time — Depth4a wateg NeI.Dr_p 30 20 PERCOLATION RATE (minutes/inch) PERFORMED ;IL kt4 19 rz s7E.oSTR FTAND - - - --- •--- BY: DATE: i 73A08 (6/79)._...._..__._._____._.. � - Municipality of Anchorage Development Services Department 4700 South Bragaw Street Anchorage, AK 995,94 SOILS LOG - PERCOLATION TEST PERFORMED FOR:_ MERIT HOMES DATE * • 49B tA1 _;t R ANDpaSON_ LEGAL DESCRIPTION:— Theresa .Mae Subd.y Lot 1A ,��\>►����� - DKZT.WG(/� SLOPE - •.; SITE'.PLAN. . 2 10, C L' 3 4 ' Je 7 C r i 124 S: 13 14 J0Z__ y. I . 15 WA6 GROUND WATER 1 rn.G�t LyN ENCOUNTERED? d414f-- IF YES. AT WHAT DEPTHI Depth to Water After Monhorinp? n o �cll $rte 1s - ,� / v,ed 4s;4vp 19 Reading — • Date - `•Gn6ss Tune : ---Net Time - 40epth to Water -Net DMp -; A8:3 i' S. F7 I r- 20 PERCOLATION RATE g.�� � �(minutm/inch) . Ma.� A TEST.RUN BETWEEN _ • l P FT AND S FT .. .._ ..... _—.__,.__.___. .. COMMENTS YfY-�' /iAVI W2� bryBio?-1CQ�-� �— .PERFORMED BY: 1'�� - CERTIFIED BY: --DATE: 72-008.(6179) MUNICIPALITY OF ANCHORAGE DEVELOPMENT SERVICES DEPARTMENT/BUILDING SAFETY DIVISION ON-SITE WATER AND WASTEWATER PROGRAM 4700 BRAGAW STREET ANCHORAGE, AK 99519 SOILS LOG - PERCOLATION TEST LEGAL DESCRIPTION: THERESA MAE S/D PERFORMED FOR. SHAWN COOLEY DATE: 4/7/2006 PROIECTNo.: M0608 PARCEL IDN: TECHNICIAN: T. L. KIMBROUGH TEMP: 39° DI:vnI TEST HOLE lA-1 Type of Test: (r«t) COMMENTS: OB/OG WELL COMPACTED DAMP SILTY SANDS W/GRAVELS SM -GM M TEST PERFORMED BY: AH WAS GROUNDWATER ENCOUNTERED? IF YES, WHAT DEPTH? DEPTH OF WATER AFTER MONITORING: DATE: No ` 49th MICHAEL E ANDERSON SITE PAN TO LOT IA GROVER DR. 3, 0% 5/20/06 DATE READING G OSS TIME MINUTES) NET TIME (MINUTES) DEPTH OF WATER (INCHES) NET DROP (INCHES) 4/7/06 TEST HOLE PRESOAKED PRIOR TO TESTING: 1 0930 10.25 CHARGE 2 1000 30 9.625 0.625 3 1000 11.0 CHARGE 4 1030 30 10.5 0.5 5 1030 11.125 CHARGE 6 1100 30 10.6251 0.5 PERCOLATION RATE: 60 (MINANCII) PERC. HOLE DIA. 6 (INCHES) TEST RUN BETWEEN:: 4_5 FT. and 5_5 FT. I, MICHAEL F. ANDERSON, CERTIFY THAT THIS TEST WAS PERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES ON THIS DATE: 5/20/06 ONSITE WASTEWATER DISPOSAL SYSTEM CONSTRUCTION AND MATERIAL SPECIFICATIONS SUBJECT: LOT 1A, THERESA MAE SUBDIVISION GENERAL: The scope of this project includes the procurement and placement of a new 1,500 -gallon septic tank at the location shown on the Site Plan. Work also includes the construction of 2 new 60' long by 3' wide by 7' effective depth absorption trenches also at the location shown on the plan. The distribution line in the trench will be placed at 2.0' below the existing ground surface. Total depth of the trench will be 9.0' below the existing ground surface. The new absorption trench must be placed a minimum of 100' from the well proposed for this lot and those on adjacent lots and 100' from any surface water in the area. A minimum of 3' of cover is required over the absorption trench and 4' of cover over the septic tank. A flow splitter valve must be placed to assure even flow to each trench. 2. Construction shall be in accordance with the approved site plan, design drawings, Municipal Permit with any special provisions or conditions, and all applicable State and Municipal Wastewater Disposal Regulations. 3. The Contractor shall be responsible for obtaining all underground utility locates and for the layout of the septic system and verification of the location of all lot lines. The Contractor must also verify the location of wells in the area and assure that the separation distances are met. 4. Unless specifically agreed otherwise, the contractor shall be responsible for final grading areas subsequently depressed from soil settling. Property owner shall be responsible for revegetation of affected areas unless specifically agreed otherwise. 5. Contractors installing wastewater disposal systems must be certified by the Municipal Division of Building Safety On -Site Water and Wastewater Program for system installations. Owners installing their own systems must receive prior approval from the On -Site Water and Wastewater Program before beginning system installation. SEPTIC TANK INSTALLATION 1. A new 1,500 gallon septic tank must be procured from an approved source and installed at the location shown. 2. A septic tank is to be constructed by a certified septic tank manufacturer. Construction shall include two 4" cleanouts for pumping access. Lot 1A, Theresa Mae Subdivision April 9, 2008 Page 2 of 3 3. The septic tank shall be sufficiently bedded to prevent settling or shifting of the tank. 4. All standpipes on the septic tank shall extend a minimum of 12 inches above final grade. 5. Tanks installed without 4' of cover shall have a minimum of 2" of direct burial insulation. 6. A foundation cleanout shall be installed one to four feet from the building foundation. Two cleanouts are required between the tank and the drainfield. 7. Final grading over the tank shall be such that a positive slope exists away from the septic tank. DRAINFIELD CONSTRUCTION: 1. The drainfield shall be constructed to the dimensions shown on the design. The bottom of the trench shall be within 2" of level. 2. Distribution piping must be placed level with perforations down atop a level bed of drainfield rock. Rock should then be placed over the pipe to provide a minimum of 2" of cover. 3. A silt barrier or geotextile fabric must be placed between the drainfield rock and the natural soil backfill. 4. Monitor tubes must be 4" in diameter and installed at the locations shown on the design. The portion below the distribution pipe must be perforated. 5. Contractor shall verify the septic tank and drainfield are a minimum 1 00'away from any private water wells in the area, 150' from a Class "C" Well or 200' from any community well. 6. Direct bury insulation must be placed over the distribution system if less than 3' of backfill depth is available. Finish grade over the trench must be mounded to prevent settlement or depressions. 7. Grade area surrounding the absorption trench to drain away. 8. A minimum 2' of accepting soil is required below the drainfield rock for a 5' wide trench. All pockets of unacceptable materials must be removed and replaced. Lot 1A, Theresa Mae Subdivision April 9, 2008 Page 3 of 3 MATERIAL SPECIFICATIONS: Septic tanks must be constructed by a municipally approved septic tank manufacturer. 2. The following pipe materials are approved for use in septic system installations in the Municipality of Anchorage: Cast Iron (perforated and solid), ASTM D3034 or P.V.C. (perforated and solid), ASTM F810 or H.D.P.E. (perforated, but not solid) and ASTM D2662 or A.B.S. (perforated and solid). 3. Insulation shall be at least 2" thick extruded direct burial polystyrene (Dow Chemical Co. Styrofoam HI or equal). 4. Septic tank inlets and outlets shall be fitted with watertight couplings (Caulder, Femco, or equal). 5. A permeable geotextile fabric (Typar, Mirafi or equal) must be installed between the final drain rock layer and the native soil layer. 6. All drain rock shall be .5" to 2.5" in diameter with less than 3% passing the #200 sieve. INSPECTIONS: Municipal Ordinance requires a minimum of two inspections. These inspections must be conducted under the supervision of a professional engineer registered in the State of Alaska. The first inspection must be conducted after the excavation of trenches, beds or pits and before the installation of any gravel. A septic tank may be set in place, but may not be backfilled. The second inspection must be conducted after the placement of the geotextile fabric, gravel, distribution piping, standpipes, cleanouts and insulation. No backfill should be in place at the time of inspection. Contractor shall provide a copy of all field survey layout and construction notes for use in preparing the certified as -built of the completed system. Ruses! Five (5) Municipality of Anchorage 3. TYPE OF WATER SUPPLY: Development Services Department iBuilding Safety Division Individual Well OnSRe Water and Wastewater Program. Individual On-site 4700 Bragaw Street Individual Water Storage P.O. Box 196650 Individual Holding Tank Anchorage, AK 99519-6650 Community Class Well www.muni.org/onsite Community On-site (907) 343-7904 Parcel I.D. CERTIFICATE OF ON-SITE SYSTEMS APPROVAL FOR A SINGLE FAMILY DWELLING 015-081.39 1. GENERAL INFORMATION Complete legal description Lot to Theresa Mae Subdivision COSA # Expiration Date: 11111/11,10 Location (site address) 71" Theresa Mae Circle Anchorage, PJC 99516 Current Property owners) Merit Homes Day phone 334-9233 Mailing address P•O•Box111982 Anchorage, AK 99511 Lending agency Day phone Mailing address Real Estate Agent Day phone Mailing Address Unless otherwise requested, COSA will be held by DSD forpickup. 2. NUMBER OF BEDROOMS: Five (5) 3. TYPE OF WATER SUPPLY: TYPE OF WASTEWATER DISPOSAL: Individual Well (] Individual On-site Individual Water Storage ❑ Individual Holding Tank ❑ Community Class Well ❑ Community On-site ❑ Public Water System ❑ Public Sewer ❑ The Municipality of Anchorage Development Services Department (DSD) issues Certificates of Onsite Systems Approval (COSA) based only upon the representations given in paragraph 4 by an independent professional civil engineer registered in the State of Alaska. Certificates of On -Site Systems Approval are required for the transfer of title (except between spouses) for properties served by a single-family on-site wastewater disposal and/or water supply sys!em. DSD also Issues COSAs upon request to homeowners. Certificates of On -Site Systems Approval are valid for 90 days from the date of issue for properties served by a private or Class C well and may be reissued with new water sample results. (Certificates may be reissued for a period of up to one year with valid water samples.) Certificates are valid for one year for properties served by Class A or B wells or a public water system. The Municipality of Anchorage Is not responsible for errors or omissions In the professional engineer's work. 4. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based on procedu outlined in the Certificate of Onsite Systems Approval Guidelines for this application, shows that theeoo►►�� rater supply and/or wastewater disposal system is (are) safe, functional and adequate for the n�te rooms and type of structure Indicated herein. I further verify that based on the information obtairt e Municipality of Anchorage files and from my investigation and inspection, the on-site water supply or wastewater disposal system is(are) In compliance with all applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation. Name of Firm Anderson Engineering Address P.O. Box 240773 Anchorage, AK 99524 Engineer's Printed Name Michael E. Anderson, P.E. 6. DSD SIGNATURE / Approved for % bedrooms. Disapproved. ✓ Conditional approval for 1�d it �J bedrooms, with the following stipulations: Phone 522-7773 Date 11/162008 C% �STEMTER FROGRAm At\ me ts' COSA Checklist X Arsenic Advisory Septic System Advisory Well Flow Advisory (n« 11M) Maintenance Agreements Supplemental Engineer's Report Other Original Certificate Date:6 v Municipality of Anchorage .. • �' Development Services Department Building Safety Division On -Site Water& Wastewater Program - `^ 4700 Bragaw Street P.O. Box 196650 Anchorage, AK 995196650 www.muni.org/onsite (907)343-7904 CERTIFICATE OF ON-SITE SYSTEMS APPROVAL CHECKLIST Legal Description: Loc tA, Theresa Mae Subdivision Parcel ID: 015.081-39 A. WELL DATA Well type Fdvate If A. B, or C provide PWSID # _ Well Log (Y/N) Y Date completed 66108 Sanitary seal (YIN) Y Wires properly protected (Y/N) Y Total depth tea fL Cased to 160 ft. C eight above ground) >24 in. FROM WELL LOG / AT INSPECTION Date Ottest 616/08 /`-cw"Qocr NA %I Static water level 69 ft. Well production 20 g.p.m. WATER SAMPLE RESULTS: Coliform' 0 colonies/100 mL Nitrate N/D mg/L Arsenic: mgll Date of sample: 1115106 B. SEPTICIHOLDING TANK DATA Tank Type/Material SephclSteel Tank size 1.500 gal. Number of Compartments TWe Foundation cleano6t (Y/N) Y Depression over tank (Y/N) N Date of pumping N" Construction Pumper C. ABSORPTION FIELD DATA AIAArr1t1)h A &60'" R II1Iq/0 g.p.m. Other bacteria 0 colonies/100 mL Collected by: A- Haraia Date installed 913108 Cleanouts (YIN) Y High water alarm (Y/N) N Date Installed slams Soil rating (g.p.d./ft2 or ft2/bdrm) A5 GPF System type S wide Trench Length " 170 ft. Width 5 ft. Gravel below pipe 4 ft. Total depth 1011 }t Eff. absorption area 1.700 ft2 Monitoring tube Y Depression over field N Date of adequacy test New Cons Results (Pass/Fail) For bedrooms Fluid depth In absorption field before test in. Water added gal. New depth in. Elapsed Time: min. Final fluid depth in. Any rejuvenation treatment (past 12 mo.) (Y/N & type) N Absorption rate >= If yes, give date �'. D. LIFT STATION Date Installed Size in gallons Manhole/Access(YIN) 'Pump on' level at _ in. 'Pump ofr level at _ in. High water alarm level at in. Datum Cycles tested Meets alar & circuit requirements? - E. SEPARATION DISTANCES 9 SEPARATION DISTANCES FROM WELL ON LOT TO: ,•49B „ . ....... 00 Septic tank/lift station on lot >1004 On adjacent lots >100' Absorption field on lot >100' On adjacent lots >100' Public sewer main N/A Public sewer manhole/cleanout N/A Sewer/septic service line >25' Holding tank N/A Animal containment areas None Manure/animal excrete storage areas None SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK ON LOT TO: Building foundation >5' Property line>5_ Absorption field >5' Water main N/A Water service line >10' Surface water >100' Wells on adjacent lots >10a SEPARATION DISTANCE FROM ABSORPTION FIELD ON LOT TO: Property line >10' Building foundation >10' Water main >1(r Water Service line >7(y Surface water >100' Driveway, parking/vehicle storage >25' Curtain drain None Noted Wells on adjacent lots >100' F. COMMENTS: COSA Fee $ 5Z -6n t fl7 / , Date of Payment Receipt Number 1) q t I)i!/% (Rev. 11105) Waiver Fee $ _ Date of Payment Receipt Number, G. ENGINEER'S CERTIFICATION r �A,Q:'�'•, 9 / certify that / have determined through field inspections and ,•49B „ . ....... 00 review of Municipal records that the above systems are 1n'. conformance with MOA COSA guidelines in effect on this date. t p : SOC...... ivwocxsoN Engineer's Printed Name Michael E. Anderson, P.E. @��c{j� ;�`'�L4381 • •N;��.; Date 11/16/2009 COSA Fee $ 5Z -6n t fl7 / , Date of Payment Receipt Number 1) q t I)i!/% (Rev. 11105) Waiver Fee $ _ Date of Payment Receipt Number, .o5! 3NNa OA68E) 0 r) w Fro ORsa�� a Zggo ZM IX -0 u 0 O�W m�5u g1580iiZ N�w0 o w w FFo ZZ Q}0 (() U U O Q K Q K W Z W z8�D� S � O pis OO 0 W O vwz �ZZN w N p a m= ZO O 41 lJ ra a Z OD OD i— o C -1 � m O J N 2 fn fn N m�� S o N w tj W > d9 N o o),n gi' C'l co IL Q N