HomeMy WebLinkAboutEAGLE CREST #1 TR A LT 50Engle Crest #1
Block A
Lot 50
#050 - 304 - 01
MUNICIPALITY OF ANCHORAGE
Development Services Department Phone: (907)343-7904
On -Site Water & Wastewater Section Fax: (907)343-7997
Certificate of On -Site Systems Approval
OSC251296
Parcel ID 050 -304-01 Expiration Date:
Legal description EAGLE CREST #1 TR A LT 50
site address 10127 CREST VIEW LN
Current property owner(s) HENEGAR TIMOTHY S JR
X The On-site system(s) is/are approved for 4 bedrooms
By:
7/14/2026
Conditional approval for bedrooms, with the following stipulations:
Comments or conditions:
Original Certificate Date:
7/31/2025
This Ce ' icate of On -Site Systems Approval (COSA) is intended to demonstrate the subject
syste s) is/are in substantial compliance with municipal code. The Municipality of Anchorage,
De lopment Service Department (DSD) issues COSAs based upon representations provided by an
in ependent professional engineer. The Municipality of Anchorage is not responsible for errors or
omissions in the professional engineer's submittal.
ATTACHMENTS:
COSA Checklist X Well Flow Advisory
Absorption Field Advisory Nitrate Advisory
Tank Age Advisory X Arsenic Advisory
Other
MUNICIPALITY OF ANCHORAGE
Development Services Department Phone: 907-343-7904
On -Site Water & Wastewater Section Fax: 907-343-7997
Certificate of On -Site Systems Approval Application
1. GENERAL INFORMATION
Parcel I.D. 050-304-01
Complete legal description EAGLE CREST #1 TR A LT 50 -
Location (site address)
10127 CREST VIEW LANE EAGLE RIVER, AK 99577
Current property owner(s) TIMOTHY HENEGAR
2. ON-SITE SYSTEMS SIZED FOR 4 BEDROOMS
Day phone
3. TYPE OF WATER SUPPLY: ❑t Private Well serving # 1 dwelling units
❑ Other Non-public well as regulated by MOA ❑ Water Storage
❑ Community Well or Public
4. TYPE OF WASTEWATER DISPOSAL: ❑■ Private Septic ❑ Private Septic serving 2 dwelling units
❑ Holding Tank ❑ Community Septic or Public Sewer
5. SEPTIC TANK: * Steel ❑ Plastic ❑ Concrete ❑ Fiberglass
Age 23 - See advisory if steel or fiberglass older than 20 years
6. ABSORPTION FIELD: ❑ AWWTS ❑ Bed 0 Deep Trench ❑ Wide Trench ❑ Seepage Pit
Waiver request for:
Expedited review requested: ❑
Distance:
By applying for this entitlement, this property is subject to inspection by municipal On-site staff
to verify the accuracy of the information provided.
COSA Fee $ ° J Waiver Fee $
Date of Payment ala a �a s Date of Payment
COSA # ( se ons dRb Waiver #
COSA Application Apr2025.doc
COSA Checklist_May2025 .docx
COSA Checklist
Legal Description: EAGLE CREST #1 TR A LOT 50 Parcel ID: 050-304-01
If more than 1 well and/or septic system on lot, provide separate checklist. Structure served by this system ____
A. WELL DATA
Well log is filed with Onsite (or attached)
Date drilled 2/22/2002 Total depth 289 ft
Cased to 287 ft
Sanitary seal is functioning correctly
Wires are properly protected
Casing height (above ground) 18+ in.
Date of flow test for COSA 7/16/25
Static water level at beginning of test 239 ft.
Well production at time of test 3.5+ gpm
Water storage tank volume None gallons
Well disinfected for coliform test? Yes No
Coliform bacteria is Negative
Nitrate mg/L Nitrate less than MRL (ND)
Arsenic ug/L Arsenic less than MRL (ND)
Collected by Date 7/14/25
Comments __________________________________________________________________________________
B. TANK DATA
Measured operating fluid level in septic tank 49"
Date of pumping 7/15/25
Required maintenance completed, if AWWTS
Comments:
C. LIFT STATION
Required maintenance completed
Age of lift station years
Lift station material
Comments:
D. DISPOSAL FIELD DATA
Which system tested (date installed) 4/13/2002
ALL standpipes present per record drawing
Total measured depth from grade 9.9 ft (max)
Measured depth to pipe invert from grade 3.5 ft (min)
N/A – pressurized field.
Per record drawings, field is insulated.
Monitor tubes (MT) go to bottom of effective. (ED)
If not, state depth into effective
Presoaked required if
(Required if house vacant or field not used for more
than 30 days prior to date of test)
Gallons introduced 2000 gallons 7/15/25 date
Any rejuvenation treatment (past 12 months) N
If yes, enter date
Adequacy test date 7/16/25
Results Pass
Fluid depth prior to test 0 in
Water added 800 gal
New fluid depth 13 in
Elapsed time 1440 min
Final fluid depth 0 in
Absorption rate 600 gpd
FIELD STATUS – POST RECOVERY
Effective depth (per record drawings) 66 in (MOA 5.5’ ED)
Effective depth used 0 in (Final Fluid Depth)
Effective depth remaining 66 in
Comments/Deficiencies:
COSA Checklist_May2025 .docx
E. SEPARATION DISTANCES
From Well on Lot to: (Please enter distances if less than required)
Septic Tank/Lift Station on Lot > 100’
Yes if No ft
Neighboring Tank > 100’ Yes if No ft
Disposal Field on Lot > 100’ Yes if No ft
Neighboring Disposal Fields > 100’
Yes if No ft
Sewer Line/Main > 100’ Yes if No ft
Sewer Manhole/Cleanout > 100’
Yes if No ft
Sewer Service/Septic Line > 25’ Yes if No ft
Holding Tank > 100’ Yes if No ft
Animal Containment > 50’ Yes if No ft
Manure/Animal Excreta Storage > 100’
Yes if No ft
N/A – Served by Community Well (not on lot) or Public Water
From Septic/Holding Tank and Disposal Field(s) on Lot to: (Please enter distances if less than required)
Tank to Foundation > 10’ Yes if No ft
Field to Foundation > 10’ Yes if No ft
Tank to Property Line > 5’ Yes if No ft
Field to Property Line > 10’ Yes if No ft
Water Main/Service Line > 10’ Yes if No ft
Surface Water > 100’ Yes if No ft
Wells on Adjacent Lots:
Wells > 100’ Yes if No ft
Community Wells > 200’ Yes if No ft
If tank or field is under driveway comment below
F. ENGINEER’S COMMENTS
G. CERTIFICATION & STATEMENT OF INSPECTION BY ENGINEER
As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based
on procedures outlined in the Certificate of On-Site Systems Approval Guidelines, indicates that the on-site water
supply and/or wastewater disposal system appears to comply with applicable Municipal and State codes,
ordinances, and regulations in effect at the time of installation, unless noted otherwise.
Name of Firm FIRST WATER CONSULTING Phone 907-350-9566
Engineer’s Printed Name CURTIS HUFFMAN, PE Date 07/21/2025
Comments: This investigation was completed in compliance with MOA guidelines, regulations,
and best industry practices / methods. The assessment of the condition of the well and septic
applies only to the conditions as of the day tested. The flow and absorption rates may change
due to subsurface conditions that may not be observed from the surface, changes in land use,
local soil characteristics, groundwater levels that may fluctuate during the year, quality of
construction (workmanship & materials), the water usage of the family being served by the
system and maintenance. The operational life of all well and septic systems are subject to
these various and dynamic characteristics and are outside the control of the evaluator of the
well and septic system. Therefore, any or NO estimate of how long a system will function satisfactory
for current or future occupants or guarantee that no unseen encroachments, deficiencies or
discrepancies exist can be given by First Water Consulting &
07/21/25
MUNICIPALITY OF ANCHORAGE
DEVELOPMENT SERVICES DEPARTMENT s 'M!
On -Site Water and Wastewater Section
www.muni.org/onsite
Septic Tank Advisory
Certificate of On -Site Systems Approval # OSC251296
Subdivision: Eagle Crest #1 Block:Tract A, Lot: 50
907-343-7904
Fax: 343-7997
The septic tank for this property is 23 years old. The average life of an asphalt
coated steel septic tank is 20 years. Typical replacement costs are $15,000 or more,
not including engineering, surveying, MOA permitting fees or site restoration.
This advisory must be attached to all copies of the subject Certificate of On -Site
Systems Approval.
This is an example of what the metal of a 30 year old steel tank MAY look like.
SGS Ref.# 50669001
Client Name Gayness Engineering Group, Ltd (GEG)
Printed Date/Time
03/07/2025
10:45
Project Name/# 10127 Crest View Lane
Collected Date/Time
02/24/2025
11:04
Client Sample ID 10127 Crest View Lane
Received Date rime
02/24/2025
13:50
Matrix Drinking Water
Technical Director
Stephen C. Ede
Sample Remarks:
Allowable Prep
Analysis
Parameter Results LOQ
Units
Method Container ID
Limits Date
Date
Init
Metals by ICP/MS
Arsenic ND 5.00
ug/L
EP200.8 B
(<10) 02/28/25 03/04/25
HBL
Waters Department
Total Nitrate/Nitrite-N ND 0.200
mg/L
SM21 450ONO3-F C
(<10)
02/26/25
MCP
Microbiology Laboratory
E. Coli Negative I
100mL
SM21 9223B A
02/24/25
M.A.
Total Coliform Negative I
100mL
SM21 9223B A
02/24/25
M.A
2of5